Loading...
HomeMy WebLinkAboutPLANS FULL SET 8.22.2023 - 23-00669 - Tagg N Go - Car WashTANK #1 AB TANK #2TANK #3 AB ControlBox Cover 809 W. Center St. Eureka IL 61530 All information contained within this document is the exclusive property of SoBrite Technologies. Copyright 2023 © Date Revisions Contents: SoBrite Technologies 08/22/23 Rev.Drafter 0 CMS Phone:(309)467-2335 Fax: (309) 467-2539 Job: Tagg N Go Express Wash Rexburg, ID Customer: Tagg N Go File Name: 08222023.dwg SHEET C Control Box ERS-100 809 W. Center St. Eureka IL 61530 All information contained within this document is the exclusive property of SoBrite Technologies. Copyright 2023 © Date Revisions Contents: SoBrite Technologies 08/22/23 Rev.Drafter 0 CMS Phone:(309)467-2335 Fax: (309) 467-2539 Job: Tagg N Go Express Wash Rexburg, ID Customer: Tagg N Go File Name: 08222023.dwg SHEET 1 Equipment Layout Control Box ERS-100 48" 30" 6" 28" Reference Point (Wall) 809 W. Center St. Eureka IL 61530 All information contained within this document is the exclusive property of SoBrite Technologies. Copyright 2023 © Date Revisions Contents: SoBrite Technologies 08/22/23 Rev.Drafter 0 CMS Phone:(309)467-2335 Fax: (309) 467-2539 Job: Tagg N Go Express Wash Rexburg, ID Customer: Tagg N Go File Name: 08222023.dwg SHEET 1A Equipment Layout w./ Dimensions 9 10' From Entrance End Of Center Trench 13 12 TANK #1 AB 4 8 6 7 135 TANK #2TANK #3 AB 2 ControlBox 3 9 Underground Plumbing Details 809 W. Center St. Eureka IL 61530 All information contained within this document is the exclusive property of SoBrite Technologies. Copyright 2023 © Date Revisions Contents: SoBrite Technologies 08/22/23 Rev.Drafter 0 CMS Phone:(309)467-2335 Fax: (309) 467-2539 Job: Tagg N Go Express Wash Rexburg, ID Customer: Tagg N Go File Name: 08222023.dwg SHEET 2 UNDERGROUND PLUMBING LEGEND 1 - 2" sch 80 PVC Pipe - Underflow Discharge - To TANK 1A 2 - 6" sch 40 PVC Pipe - External Crossover - From TANK 1B to TANK 2A 3 - Two 6" sch 40 PVC Pipes - Center Trench - To TANK 1B 4 - 4" or 6" sch 40 PVC Pipe - Overflow to O/W/S - From TANK 2B 5 - 6" sch 40 PVC Pipe - External Crossover - From TANK 2B to TANK 3 6 - 4" sch 80 PVC Pipe - Filter Pump Suction Line - From TANK 3 7 - 4" sch 80 PVC Pipe - Optional Extra Suction Line - From TANK 3 8 - 6" sch 40 PVC Pipe - AquaPrep Discharge - Split To TANK 3 9 - 6" sch 40 PVC Pipe - AquaPrep Discharge - Split To Center Trench 12 - 6" sch 40 PVC Pipe - Internal Crossover - From TANK 1A to TANK 1B 13 - 6" sch 40 PVC Pipe - Internal Crossover - From TANK 2A to TANK 2B Plumbing Paths Drawn for Clarity ONLY! USE BEST PRACTICE! Control Box 21" (1,6,9) 15" (7,8) 3" (1) 5" (8) 12" (9) 24" (6,7) Reference Point (Wall) 809 W. Center St. Eureka IL 61530 All information contained within this document is the exclusive property of SoBrite Technologies. Copyright 2023 © Date Revisions Contents: SoBrite Technologies 08/22/23 Rev.Drafter 0 CMS Phone:(309)467-2335 Fax: (309) 467-2539 Job: Tagg N Go Express Wash Rexburg, ID Customer: Tagg N Go File Name: 08222023.dwg SHEET 2A Underground Plumbing Stub-Up Details UNDERGROUND PLUMBING LEGEND 1 - 2" sch 80 PVC Pipe - Underflow Discharge - To TANK 1A 6 - 4" sch 80 PVC Pipe - Filter Pump Suction Line - From TANK 3 7 - 4" sch 80 PVC Pipe - Optional Extra Suction Line - From TANK 3 8 - 6" sch 40 PVC Pipe - AquaPrep Discharge - Split To TANK 3 9 - 6" sch 40 PVC Pipe - AquaPrep Discharge - Split To Center Trench Plumbing Paths Drawn for Clarity ONLY! USE BEST PRACTICE! 2" MIN. - 6" MAX. WALL UNDERGROUND PIPE/CONDUIT TO TANK OR DRAIN EQUIPMENT ROOM FLOOR TYPICAL STUB-UP 2" FROM WALL STUB-UP DETAILS 12" - 24" ba TANK #2TANK #3 AB Control Box Underground Electrical Details 809 W. Center St. Eureka IL 61530 All information contained within this document is the exclusive property of SoBrite Technologies. Copyright 2023 © Date Revisions Contents: SoBrite Technologies 08/22/23 Rev.Drafter 0 CMS Phone:(309)467-2335 Fax: (309) 467-2539 Job: Tagg N Go Express Wash Rexburg, ID Customer: Tagg N Go File Name: 08222023.dwg SHEET 3 UNDERGROUND ELECTRICAL LEGEND a - 1" PVC Conduit - Low Water Protection Float Switch (FS-2) - TANK 3 b - 1" PVC Conduit - FOR FUTURE USE - TANK 2B Electrical Conduit Paths Drawn for Clarity ONLY! USE BEST PRACTICE! Control Box 28" (b) 26" (a) Reference Point (Wall) 2.5" (a,b) Underground Electrical Stub-Up Details w./ Dimensions 809 W. Center St. Eureka IL 61530 All information contained within this document is the exclusive property of SoBrite Technologies. Copyright 2023 © Date Revisions Contents: SoBrite Technologies 08/22/23 Rev.Drafter 0 CMS Phone:(309)467-2335 Fax: (309) 467-2539 Job: Tagg N Go Express Wash Rexburg, ID Customer: Tagg N Go File Name: 08222023.dwg SHEET 3A UNDERGROUND ELECTRICAL LEGEND a - 1" PVC Conduit - Low Water Protection Float Switch (FS-2) - TANK 3 b - 1" PVC Conduit - FOR FUTURE USE - TANK 2B Electrical Conduit Paths Drawn for Clarity ONLY! USE BEST PRACTICE! 2" MIN. - 6" MAX. WALL UNDERGROUND PIPE/CONDUIT TO TANK OR DRAIN EQUIPMENT ROOM FLOOR TYPICAL STUB-UP 2" FROM WALL STUB-UP DETAILS 12" - 24" PVC Union THREE 2,500-GALLON PRECAST CONCRETE TANKS 156" Length x 78" Width x 84" Height TANK #1 - 1A Underflow - 1B Primary Settlement TANK #2 - Secondary Settlement w./ Baffle TANK #3 - Process Tank PLUMBING LEGEND 1 - 2" sch 80 PVC Pipe - Underflow Discharge - To TANK 1A 2 - 6" sch 40 PVC Pipe - External Crossover - From TANK 1B to TANK 2A 3 - Two 6" sch 40 PVC Pipes - Center Trench - To TANK 1B 4 - 4" or 6" sch 40 PVC Pipe - Overflow to Sewer - From TANK 2B 5 - 6" sch 40 PVC Pipe - External Crossover - From TANK 2B to TANK 3 6 - 4" sch 80 PVC Pipe - Filter Pump Suction Line - From TANK 3 7 - 4" sch 80 PVC Pipe - Optional Extra Suction Line - From TANK 3 8 - 4" or 6" sch 40 PVC Pipe - AquaPrep Discharge - To TANK 3 12 - 6" sch 40 PVC Pipe - Internal Crossover - From TANK 1A to TANK 1B 13 - 6" sch 40 PVC Pipe - Internal Crossover - From TANK 2A to TANK 2B ELECTRICAL LEGEND a - 1" PVC Conduit - Low Water Protection Float Switch (FS-2) - TANK 3 b - 1" PVC Conduit - FOR FUTURE USE - TANK 2B NOTES: - All underground plumbing & tanks by other. - Actual tank dimensions may vary. - Plumbing should be placed as shown regardless of what tanks are used. - All pipes must be set below frost line. - Suction lines MUST be sch 80 PVC. - Do NOT install screens on foot valve. - All tank bottoms should be same elevation. - Consult engineer for elevations. B Low Water Protection Float Switch (FS-2) - Locate 18" from Bottom of Float Weight 84" 3" Typ. Air Gap 150" 71" 1 3 4 8 7 6 1" PVC Conduit from Junction Box in Manway 3" Typ. Thickness A 78"72" 7"7" 18" 3" Typ. Thickness 26" 32" Maintain 12" Min. Gap From Walls & Between Suction Lines 6"7" 9" 4" Floor Foot Valve (By SoBrite) TANK #2TANK #1 SIDE VIEW TOP VIEW 1/2 TANK TYP.1/2 TANK TYP. 24" SOBRITE ERS 100 3-TANK LAYOUT Three 2,500 Gallon Precast Concrete Tanks TANK #3BA b 12 13 5 2 156" 12"20" 21"8" 17" 12" 24" Typ. Manway a DRAWING NOT TO SCALE 7" (If Foot Valve is Raised, The Float Switch Also Needs to be Raised) Keep a 10" Distance Between Them! 12" Tanks by Geneva Pipe 1465 West 400 North Orem, UT 84057 Phone #: (801) 225-2416 VERY IMPORTANT - PLEASE READ CAREFULLY! IF THE TANKS AS SHOWN ON THIS PRINT ARE NOT THE TANKS BEING USED, STOP! CONSULT SOBRITE FOR NEW TANK DRAWING Underground Reclaim Tank Details 809 W. Center St. Eureka IL 61530 All information contained within this document is the exclusive property of SoBrite Technologies. Copyright 2023 © Date Revisions Contents: SoBrite Technologies 08/22/23 Rev.Drafter 0 CMS Phone:(309)467-2335 Fax: (309) 467-2539 Job: Tagg N Go Express Wash Rexburg, ID Customer: Tagg N Go File Name: 08222023.dwg SHEET 4 FLOOR WALL PUMP GROUND LEVEL TANKYESü FLOOR WALL PUMP GROUND LEVEL TANKNO!x FLOOR WALL PUMP GROUND LEVEL TANKNO! FLOW AIR TRAP FLOW FLOW AIR TRAP 1. ALL suction lines require a continuous upward slope from the reclaim tanks to the equipment room. 2. ALL suction lines must NEVER slope down & then back up again (AIR TRAP ). 3. ALL suction lines must NEVER slope up & then back down again (AIR TRAP ). x BELOW GROUND RECLAIM TANKS PRESSURE TESTING PUMP SUCTION LINES Schrader Valve Stem Air Chuck Compressed Air NOTES: - Pressure test all suction lines upon installation @ 10-15 psi max. - VERY IMPORTANT: Keep pressure on suction lines for THE ENTIRE DURATION of construction. - Pressure should NOT drop more than 2 PSI. - Watch for problems when excavating driveways. - If reclaim tanks are located on opposite side of equipment room, increase suction line to next size larger. - Placement of suction lines is critical. - Do NOT put screens on the suction lines. 1/4" x 1/8" Brass Bushing 1/4" Brass Tee 1/4" x 1/8" Brass Hex Nipple 1/8" MNPT x Schrader Valve Stem 0-100 PSI Pressure Gauge - 1/4" MNPT THE INFORMATION ON THIS PAGE IS CRITICAL FOR SUCTION TO OPERATE PROPERLY PLEASE READ CAREFULLY! UNDER GROUND PLUMBING EXAMPLES: 809 W. Center St. Eureka IL 61530 All information contained within this document is the exclusive property of SoBrite Technologies. Copyright 2023 © Date Revisions Contents: SoBrite Technologies 08/22/23 Rev.Drafter 0 CMS Phone:(309)467-2335 Fax: (309) 467-2539 Job: Tagg N Go Express Wash Rexburg, ID Customer: Tagg N Go File Name: 08222023.dwg SHEET 4A Proper Slope and Pressure Testing Details Control Box 9 8 14 11 10 67 ERS-100 1 Above Ground Plumbing Details 809 W. Center St. Eureka IL 61530 All information contained within this document is the exclusive property of SoBrite Technologies. Copyright 2023 © Date Revisions Contents: SoBrite Technologies 08/22/23 Rev.Drafter 0 CMS Phone:(309)467-2335 Fax: (309) 467-2539 Job: Tagg N Go Express Wash Rexburg, ID Customer: Tagg N Go File Name: 08222023.dwg SHEET 5 ABOVE GROUND PLUMBING LEGEND 1 - 2" sch 80 PVC Pipe - Underflow Discharge - To TANK 1A 6 - 4" sch 80 PVC Pipe - Filter Pump Suction Line - From TANK 3 7 - 4" sch 80 PVC Pipe - Optional Extra Suction Line - From TANK 3 8 - 6" sch 40 PVC Pipe - AquaPrep Discharge - Split To TANK 3 9 - 6" sch 40 PVC Pipe - AquaPrep Discharge - Split To Center Trench 10 - 2" Pipe - Reclaim Water Outlet - From ERS to Car Wash Equipment 11 - 2" Pipe - Fresh Water Inlet - From City Water Source to ERS 14 - 2" sch 80 PVC Pipe - AquaPrep Discharge tee' d w./ Ball Valve for Flow Control - Approximately 20% to Pipe (8) - Approximately 80% to Pipe (9) Plumbing Paths Drawn for Clarity ONLY! USE BEST PRACTICE! Control Boxa cd ERS-100 b Above Ground Electrical Details 809 W. Center St. Eureka IL 61530 All information contained within this document is the exclusive property of SoBrite Technologies. Copyright 2023 © Date Revisions Contents: SoBrite Technologies 08/22/23 Rev.Drafter 0 CMS Phone:(309)467-2335 Fax: (309) 467-2539 Job: Tagg N Go Express Wash Rexburg, ID Customer: Tagg N Go File Name: 08222023.dwg SHEET 6 ABOVE GROUND ELECTRICAL LEGEND a - 1" PVC Conduit - Low Water Protection Float Switch (FS-2) - TANK 3 b - 1" PVC Conduit - FOR FUTURE USE - TANK 2B c - 480 VAC 60Hz 3 Phase 7.6 fla - 5 HP Filter Pump on ERS-100 Reclaim Unit d - 120 VAC Control Circuit Feed Electrical Paths Drawn for Clarity ONLY! USE BEST PRACTICE! ERS FIELD CONNECTIONS Field connections are to only be made at terminal strip. Factory wiring connects terminal strip to components. 120 VAC Control Circuit Feed FS-2 Low Water Protection Float Switch - In Reclaim Suction Tank Ground to Ground Terminal 1M 1CB 2CB 3 Phase Power In L1-L2-L3 GN D GN D GN D GN D 1L 1 1L 2 1L 3 L N N 1 I6 A I6 A I6 A I6 I7 I8 N N N B1 B2 B3 B4 B5 B6 B7 B8 COMPONENT LEGEND EASY-A4-AC-12RC1 - Control Relay 1CB - Main Control Circuit Protector 2CB - Ballast Circuit Protector 1M - Filter Pump Motor Starter SOBRITE 809 WEST CENTER EUREKA, IL 309-467-2335 MM/DD/YYYY HH:MM (Day and Time) ERS 7 PGM** (**equals Program Number) DEL ALT ESC OK EASY-A4-AC-12RC1 120 VAC INPUTS & OUTPUTS POW/RUN EASY-E4-AC-8RE1 INPUTS OUTPUTS â DISPLAY SCREEN â I1 E I2 E I3 E I4 E Q3 Q4 Q1 E Q2 E Electrical Details - ERS-100 Gen. 3 Field Connections 809 W. Center St. Eureka IL 61530 All information contained within this document is the exclusive property of SoBrite Technologies. Copyright 2023 © Date Revisions Contents: SoBrite Technologies 08/22/23 Rev.Drafter 0 CMS Phone:(309)467-2335 Fax: (309) 467-2539 Job: Tagg N Go Express Wash Rexburg, ID Customer: Tagg N Go File Name: 08222023.dwg SHEET E1 SOBRITE 809 WEST CENTER EUREKA, IL 309-467-2335 MM/DD/YYYY HH:MM (Day and Time) ERS 7 PGM** (**equals Program Number) DEL ALT ESC OK EASY-E4-AC-12RC1 120 VAC INPUTS & OUTPUTS P3 - (3 o'clock) Press Button to Display the UV Lamp Hour Screen. Press and Hold Button to Cycle Through Counters. Release Button to Return to Display UV Lamp Hour Screen. Press Button Again to Return to Default Screen. P4 - (6 o'clock) After Replacing The UV Lamps and Check Valves, Press and Hold for 15 Seconds to Reset The Hour Counter. POW/RUN P2 - (12 o'clock) Press Button to Display the Input/Output Screen. Press Button Again to Return to Default Screen. EASY-E4-AC-8RE1 P1 - (9 o'clock) Not Used. INPUTS OUTPUTS â DEFAULT SCREEN â Electrical Details - ERS-100 Gen. 3 PLC Screen 809 W. Center St. Eureka IL 61530 All information contained within this document is the exclusive property of SoBrite Technologies. Copyright 2023 © Date Revisions Contents: SoBrite Technologies 08/22/23 Rev.Drafter 0 CMS Phone:(309)467-2335 Fax: (309) 467-2539 Job: Tagg N Go Express Wash Rexburg, ID Customer: Tagg N Go File Name: 08222023.dwg SHEET E2 Fiber-optic lenses located on bottom section of UV chambers. A purple glow can be seen while the Filter Pump is in operation. UV LAMP INSTALLATION Remove the 3" gray plastic threaded plugs from the top of the UV chambers, then install the UV lamps. Connect the white plugs to each lamp. LAMPS ARE FRAGILE. Use caution when inserting lamps into the UV chambers. UV lamps are shipped separately in white cardboard boxes. Re-Install 3" Gray Plastic Threaded Plug. UV Chambers PUMP OFF HANDAUTO ALARM GAUGE 2 GAUGE 1 AIR FLOW Electrical Details - UV Lamp Installation Details 809 W. Center St. Eureka IL 61530 All information contained within this document is the exclusive property of SoBrite Technologies. Copyright 2023 © Date Revisions Contents: SoBrite Technologies 08/22/23 Rev.Drafter 0 CMS Phone:(309)467-2335 Fax: (309) 467-2539 Job: Tagg N Go Express Wash Rexburg, ID Customer: Tagg N Go File Name: 08222023.dwg SHEET E3 ERS-100 Underground Stub-Ups & Pipe Connections in Equipment Room - Top View ERS-100 Pipe Connections - Side View WALL 4" or 6" sch 40 PVC to TANK 3 2" sch 80 PVC AquaPrep Discharge (BOTTOM PIPE) Tee' d w./ Ball Valves for Flow Control - To 4" or 6" sch 40 PVC Pipe to Center Trench* - To 4" or 6" sch 40 PVC to TANK 3 * Run Pipe 10' from Entrance End 2" sch 80 PVC Reclaim Water Outlet 2" Fresh Water Inlet éé THIS SIDE FRONT éé 4" sch 80 PVC Filter Pump Suction Line from TANK 3 1" PVC Conduits - To TANK 2B 48" 30" 6" MAX. 7" 2" 12" 24" 7" 6" 5" 1" PVC Conduits - To TANK 3 2" sch 80 PVC Underflow Discharge to TANK 1A - TOP PIPE 4" sch 80 PVC Optional Extra Suction Line from TANK 3Control Box 2" sch 80 PVC Reclaim Water Outlet 2" sch 80 PVC Underflow Discharge to TANK 1A 2" Fresh Water Inlet 2" sch 80 PVC AquaPrep Discharge Split w./ Ball Valves for Flow Control 3" sch 80 PVC - Filter Pump Suction 2" MIN. WALL UNDERGROUND PIPE/CONDUIT TO TANK OR DRAIN EQUIPMENT ROOM FLOOR TYPICAL STUB-UP STUB-UP DETAIL 12" - 24" 4" or 6" sch 40 PVC Stub-Up to TANK 3 4" sch 80 PVC Stub-Up Optional Extra Suction Line from TANK 3 4" or 6" sch 40 PVC Stub-Up to Center Trench 2" sch 80 PVC Stub-Up Underflow Discharge to TANK 1A 4" sch 80 PVC Stub-Up Filter Pump Suction Line from TANK 3 Plumbing Details - ERS-100 Gen. 3 Pipe Connections and Stub-up Details 809 W. Center St. Eureka IL 61530 All information contained within this document is the exclusive property of SoBrite Technologies. Copyright 2023 © Date Revisions Contents: SoBrite Technologies 08/22/23 Rev.Drafter 0 CMS Phone:(309)467-2335 Fax: (309) 467-2539 Job: Tagg N Go Express Wash Rexburg, ID Customer: Tagg N Go File Name: 08222023.dwg SHEET P1 YES ü NO! x 8" 10" 18" CRITICAL MEASUREMENT The Low Water Protection Float Switch (FS-2) Must have adequate space in order to work correctly 10" higher than the inlet of the suction line 18"18" THIS FLOAT SWITCH MUST BE RAISED TO 28" (18" + 10") If the Suction Line is Raised, the Float Switch MUST be Raised as well. Otherwise, the Float Switch will be Unable to Function Properly due to Suction Interference ß OK TOO HIGH Proper Float Switch and Suction Line Placement 809 W. Center St. Eureka IL 61530 All information contained within this document is the exclusive property of SoBrite Technologies. Copyright 2023 © Date Revisions Contents: SoBrite Technologies 08/22/23 Rev.Drafter 0 CMS Phone:(309)467-2335 Fax: (309) 467-2539 Job: Tagg N Go Express Wash Rexburg, ID Customer: Tagg N Go File Name: 08222023.dwg SHEET P2