Loading...
HomeMy WebLinkAboutAPPROVED REDLINED SHEET REPORT - 23-00669 - Tagg N Go - Car WashDescription : Tagg N Go - Car Wash Address : 1365 N 2nd E Record Type : New Commercial Building Document Filename : 23-00669 - Sheet Report-Reviewed-Corrections-Required.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 23-00669 New Commercial Building Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) Author Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : Tagg N Go - Car Wash Address : 1365 N 2nd E Application Type : Document Filename : 23-00669 - Sheet Report.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required # 23-00669 New Commercial Building Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 11.01.2023 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) Document Name Document ID 2022.03.12_ROOF PANEL LAYOUTS.pdf 27539 TAGG-N-GO CAR WASH_SITE_092123.pdf 27535 2021.11.19_WALL PANEL SHOPS_REVISED.pdf 27541 TaggNGo_Rexburg_PermitSet_092823.pdf 27537 TaggNGo_Rexburg_PermitSet_091923.pdf 27368 2021.11.19_WALL PANEL LAYOUT_REVISED.pdf 27540 Author Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Don Allen Don.Allen@rexburg.org 208-372-2174 Alex Owens Alex.Owens@rexburg.org 208-372-2172 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments E000 Free Text Alex Owens : Electrical Open 18 All electrical work must meet 2017 NEC requirements. As per engineer, concrete encased electrode must be 20 feet 1/0 copper installed in footing of building. Comment Author Contact Information: Original Documents: Corrections in the following table need to be applied before a permit can be issued Review Plan / Sheet Report # 23-00669 New Commercial Building Description : Tagg N Go - Car Wash Address : 1365 N 2nd E Record Type : Approval of plans does not constitute approval of variance from code Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments T-1.0 Free Text Kyle Baldwin : P&Z Open 63 Plat has not been approved yet. I need it approved prior to building/Site Plan approval. Please submit full Site Plan for approval Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) 14'' w toe e e e sd sd to b tobto b ss ss ss ss ss ss ss ss ss ss ss ss w w S ssssssss pp pp pp fl 14'' w R18 . 5 ' 11.4' 3. 9 ' 9 . 1 ' 7.7' 5' 6. 8 ' R3 0 ' 5'6.5' 3. 9 ' 0.8'6'4.5' R23 . 5 ' 6.5 ' 3. 9 ' R 2 ' R3' R 1 5 ' R 5 5 . 9 ' R 1 2 . 5 ' R13 . 5 ' R39. 5 ' R2 . 7 ' R3' R 1 9 . 5 ' R3' R7' R2' R 1 0 ' R 1 2 . 5 ' R 1 8 ' R 1 4 ' R1 5 ' R2 2 . 5 ' 14.8' 19 . 5 ' 17 . 5 ' 9.8'5' 2. 4 ' 27.2' 55' 12.8'16 . 5 ' 3. 2 ' 3. 4 ' 17.9' 46.3' 43 . 2 ' 277.1' 36.5' 36.5' 29 . 5 ' 45 . 6 ' 5.1' 5.1'36 . 6 ' 10 . 2 ' 5' 225.9' 8' 3' 3' 8' 4.5'17.2' 17 . 5 ' 33'2'2' 2' 10 . 3 ' 41 . 6 ' 4' 20 ' TY P 9.8' TYP 3.5' TYP 20 ' TY P 9' TYP 6.3' 7. 6 ' 17 . 3 ' 51.2' 13 8 . 7 ' R10 . 5 ' 32 7 ' 8 . 8 ' 8.8 ' 24' 297.2' 5' 5.9' 6'24' 6. 5 ' 291.2' 5' R15' 19. 3 ' 19. 3 ' 19 6 . 5 ' R10 ' 5'15.7' 8.7 ' 8. 6 ' 15.7' 36 ' 30 ' 6' 6' 14 ' 8. 1 ' 6.1' 5.9' R4 ' R3 ' 22 . 2 ' 15 ' 16 . 4 ' 27 ' 25 ' 25 ' 24' 24.5' 24' 1 5 . 5 ' 22 ' 14 . 5 ' 35 ' 150' 7. 7 ' 5' 41 ' 73.5'74' 37.1' 73.5'74'37.1' 4' 4'4' 4'4' 5' 5' 38 . 1 ' 5' 4' 5'5' 12' 12.1' 4. 9 ' 3.4' 6' 16.6' 3' 4. 5 ' 11.6'7' 7' 22' 5' 3'9.5' 55.1'34'3.3' 14' 5. 1 ' 5. 1 ' 5. 1 ' 207.2'8' 3' 20 . 2 ' 4. 5 ' 22.1' 17 . 1 ' 5' R18 . 5 ' 5' 5' 6. 5 ' 10' 11.2' 1 0 . 9 ' 8.7 ' 11' R 2 3 . 5 ' 1 5 . 2 ' 17.3' 37.5' 11 9 . 3 ' 26' 2.5' 24' R1 5 ' R10' 4' 0. 5 ' R4' 4'5. 4 ' 8' 6' 10' 12' 7' H:\!2023\id-8116-23 rexburg - tagg-n-go car wash\project data\02 CAD\2.03 sheet files\construction drawings\C.3.1_SITE PLAN.dwg - SITE PLAN - 9/21/2023 11:26am, jalen.fuhriman 1 5 RE V I S I O N S RE V # DA T E DR A W I N G I N F O DA T E DE S I G N E D DR A W N *S E E G E N E R A L N O T E S S H E E T WA R N I N G 0 1 2 IF T H I S B A R D O E S N O T ME A S U R E 2 " T H E N DR A W I N G I S N O T T O S C A L E CI T Y R E V I E W S E T ww w . h o r r o c k s . c o m PAGE C PR O J E C T CH E C K E D D B A # 2 3 4 21 9 4 S n a k e R i v e r P k w y . , S u i t e 2 0 5 Id a h o F a l l s , I D 8 3 4 0 2 (2 0 8 ) 5 2 2 - 1 2 2 3 PRELIMINARY NOT FOR CONSTRUCTION 1 09 / 1 5 / 2 0 2 3 H O R R O C K S E N G I N E E R SN 0 20'40' SCALE: 1" = 20' SHEET NOTES: 1.DRIVE AISLE DIMENSIONS MEASURED TO FACE OF CURB, WHERE CURB IS PROPOSED OR TO EDGE OF PAVEMENT OTHERWISE. SITE PLAN KEYNOTES INSTALL LIGHT DUTY ASPHALT (SEE FLEXIBLE PAVEMENT SECTION SUMMARY TABLE SHEET C.3.1) INSTALL HEAVY DUTY ASPHALT (SEE FLEXIBLE PAVEMENT SECTION SUMMARY TABLE SHEET C.3.1) INSTALL 1.5' FLAT PAN CURB & GUTTER SEE DETAIL 1 SHEET C.3.1 INSTALL 1.5' FLAT PAN CURB & GUTTER W/ DEPRESSED CURB HEAD PER DETAIL 2 SHEET C.3.1 TIE INTO EXISTING ASPHALT, SAWCUT AS REQUIRED INSTALL 4" THICK SIDEWALK, (WIDTH PER PLAN) PER ISPWC SD-709, 714, 714A, 714B (2020) UNLESS OTHERWISE NOTED INSTALL BOLLARD PER DETAIL 3 SHEET C.3.1 ADA SIGN PER DETAIL 4 SHEET C.3.1 INSTALL ADA RAMP WITH TRUNCATED DOMES PER ISPWC SD - 712A (2020) INSTALL LANDSCAPE PER LANDSCAPE PLAN STRIPING PER MUTCD STANDARDS INSTALL CONCRETE PAVEMENT PER PCCP PAVEMENT SECTION PER TABLE SHEET C.3.1 INSTALL TRASH ENCLOSURE PAD PER DETAIL 5 SHEET C.3.1 INSTALL "NO ENTRY" SIGN PER MUTCD STANDARDS INSTALL CURB TRANSITION PER ISPWC SD-707 (2020) (LENGTH PER PLANS) INSTALL STOP SIGN PER MUTCD STANDARDS INSTALL WHEEL BLOCK INSTALL HEATED CONCRETE PER MANUFACTURES SPECIFICATIONS INSTALL RIGHT TURN ONLY SIGN PER MUTCD STANDARDS INSTALL TRAFFIC LIGHT PER ELECTRICAL PLANS INSTALL COMMERCIAL APPROACH PER CITY OF REXBURG STANDARDS SHEET 7 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 ID - 8 1 1 6 - 2 3 CJ F NM C TL M 08 / 3 0 / 2 0 2 3 SI T E P L A N TA G G - N - G O C A R W A S H RE X B U R G , I D A H O 6 C.3.1 MOODY RD N 2 N D E PROPOSED BUILDING ± 5443 SF 02 02 02 02 02 01 01 01 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 0303 03 04 03 03 03 03 03 03 03 05 05 04 03 04 03 03 03 03 03 03 04 04 03 03 0404 04 04 04 04 06 06 06 06 06 06 06 06 07 08 09 09 03 04 03 03 04 04 10 10 10 10 10 10 10 10 10 10 10 10 10 10 STORM SWALE 111111 11 11 11 11 11 12 12 12 12 12 13 03 04 03 14 14 14 14 10 10 10 16 05 05 11 11 12 17 11 10 18 18 C.3.2 6 09 09 04 04 04 04 MATCH CITY CURBING DURING INSTALL CONTRACTOR TO BRING THIS SECTION TO PIT RUN GRADE IN ORDER TO PREPARE FOR FUTURE DEVELOPMENT. ROAD SECTION TO BE INSTALLED IN THE FUTURE 20 18 6 21 INSTALL RIGHT TURN ONLY PORKCHOP19 R1' R 4 . 5 ' R4 . 5 ' R1 ' R 1 ' 3' 04-30-2025 Date Stamped: Expiration Date: 09-19-2023 PRO F E S S I O N A L EN GI N E E R L I C E NSE D S T A TE OF I D A H O 14893 J O SEPH W . T A F T All electrical work must meet 2017 NEC requirements. As per engineer, concrete encased electrode must be 20 feet 1/0 copper installed in footing of building. JOBSITE LEVELING OF ADJACENT MEMBERS MAY BE NECESSARY. THIS IS ESPECIALLY IMPORTANT FOR SLABS THAT BECOME A FINISHED CEILING. PRESTRESSING INTRODUCES A SLIGHT UPWARD "BOW" OR CAMBER IN THE HOLLOWCORE. THIS OPERATION IS TYPICALLY THE RESPONSIBILITY OF THE ERECTOR AND IS EXPECTED WHEN A SMOOTH UNDER SURFACE IS IMPORTANT. IT IS SOMETIMES POSSIBLE TO MINIMIZE DIFFERENCES BY SHIMMING UNDER THE ENDS AT THE WALL. GROUTING OF THE JOINTS OR "KEYWAYS" SHALL BE ACCOMPLISHED IN A GOOD WORKMANLIKE MANNER USING PORTLAND CEMENT. GROUT CONSISTS OF THREE PARTS CLEAN CONCRETE SAND AND AT LEAST ONE PART PORTLAND CEMENT. MIXTURES SHALL BE OF A CONSISTENCY THAT REQUIRES "RODDING" OR "TAMPING" INTO PLACE. KEYWAYS SHALL BE TAMPED FULL FOR THE ENTIRE LENGTH PRIOR TO POURING FLOOR TOPPING. SLABS THAT DO NOT BEAR SQUARELY AND SMOOTHLY ON THE BEARING WALLS SHALL BE PROVIDED WITH LEVEL BEARING BY PACKING OR "POINTING" VOIDED SPACES WITH GROUT. OPENING MAY BE CUT IN THE FIELD ONLY SO LONG AS NO REINFORCING STRANDS ARE CUT. CONTACT TETON PRESTRESS PRIOR TO FIELD CUTTING OF ANY OPENINGS. TETON PRESTRESS CONCRETE ACCEPTS RESPONSIBILITY FOR DESIGN OF THE PRESTRESS MEMBERS ONLY. DESIGN OF FOOTINGS, CIP WALLS, BEAMS ETC SHALL BE THE RESPONSIBILITY OF THE OWNER. PANELS THAT ARE GREATER THAN 27'-0" IN LENGTH REQUIRE TEMPORARY SHORING AT MID SPAN DURING PLACEMENT AND CURING (7 DAY MINIMUM) OF TOPPING SLAB WHERE NOTED: PANELS THAT HAVE BEVEL CUT ENDS REQUIRE TEMPORARY SHORING AT END WITH BEVEL CUT DURING PLACEMENT AND CURING (7 DAY MINIMUM) OF TOPPING SLAB F1 RP1 (1) @ 3'-7" RP2 RP6RP 5 RP9 RP10 RP10A RP11RP11 RP11A RP4 RP6ARP6 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP2 RP3 RP4 RP4 RP4 RP4A (30) @ 4'0" = 120'-0" 12'-0" 135'-7" 123'-7" 20 ' - 0 " 35 ' - 0 " 15 ' - 0 " (1) @ 1'-7"(27) @ 4'-0" = 108'-0"(1) @ 4'-0"(2) @ 4'-0" = 8'-0"(3) @ 4'-0" = 12'-0" 133'-7" 5' - 0 " 40 ' - 0 " 17 ' - 0 " 23 ' - 0 " RO O F P A N E L @ 1 8 ' - 1 0 " RO O F P A N E L @ 1 8 ' - 1 0 " RO O F P A N E L @ 1 4 ' - 6 " RO O F P A N E L @ 1 4 ' - 6 " RO O F P A N E L @ 1 9 ' - 2 " RO O F P A N E L @ 1 5 ' - 6 " RP6RP6BRP6 RP6RP4RP6RP6RP6CRP6RP6 RP6ERP6RP6DRP6RP6RP6RP6RP6RP6RP6RP6RP6 RP6 RP8RP7 RO O F P A N E L @ 1 8 ' - 6 " RO O F P A N E L @ 1 4 ' - 2 " F1 F2 F7 F7 F5 F4 F4 F3 F6 F3 F1 F1 (4) R15 ACROSS PANEL (3) R15 ACROSS PANEL (2) R15 ACROSS PANEL (3) R15 ACROSS PANEL (4) R15 ACROSS PANEL 20'-0" (4) R15 ACROSS PANEL (3) R15 ACROSS PANEL (2) R15 ACROSS PANEL (3) R15 ACROSS PANEL (4) R15 ACROSS PANEL 12'-10"3'-0"10'-6"1'-8"64'-10"3'-0"17'-0"3'-0"19'-2" 6' - 1 0 " 4' - 0 " 11 ' - 0 " 1' - 8 " 12 ' - 6 " 4' - 0 " 12 ' - 0 " 3' - 0 " SCALE: ROOF PANEL LAYOUT 3/16" = 1'-0" NORTH SHEET NO. PR O J E C T : JO B N O . : PR O J E C T M A N A G E R : CA D O P E R A T O R : TE T O N P R E S T R E S S C O N C R E T E ID A H O F A L L S , I D A H O 8 3 4 0 1 RE V . DA T E BY DE S C R I P T I O N 2 3 4 51 E1 DR S H I N E C A R W A S H N 2 N D E / W 2 0 0 0 N RE X B U R G , I D GT C DB P IF 2 1 - 3 5 6 # # # # # # # # # # SS pp pp FND5/8"IRLS14222 5104875.38 fl 04-30-2025 Date Stamped: Expiration Date: 09-19-2023 PRO F E S S I O N A L EN GI N E E R L I C E NSE D S T A TE OF I D A H O 14893 J O SEPH W . T A F T SS pp pp FND5/8"IRLS14222 5104875.38 fl 1.5 1.4 1.0 0.4 0.2 0.2 0.5 0.8 1.0 0.8 0.8 1.5 1.5 1.1 0.4 0.2 0.3 0.6 1.1 1.3 1.2 0.8 0.8 1.5 0.5 0.3 0.4 0.7 1.6 1.6 1.1 1.2 0.7 0.4 0.5 0.8 1.4 1.6 1.6 0.7 0.9 0.8 0.6 0.6 0.9 1.5 1.7 1.6 0.8 0.9 0.8 0.8 1.1 1.5 1.6 1.5 1.1 1.0 1.0 1.1 1.3 1.4 1.4 1.1 0.8 1.4 1.4 1.4 1.4 1.4 1.2 0.9 0.6 1.4 1.6 1.6 1.5 1.3 1.1 0.8 0.6 1.1 1.6 1.6 1.6 1.3 1.0 0.7 0.5 1.4 1.7 1.7 1.6 1.4 1.1 0.8 0.6 1.4 1.5 1.6 1.6 1.5 1.2 0.9 0.6 1.0 1.2 1.4 1.6 1.6 1.4 1.1 0.8 0.9 1.1 1.3 1.5 1.7 1.7 1.5 1.1 0.9 1.1 1.3 1.5 1.8 1.8 1.7 1.0 1.0 1.1 1.3 1.5 1.8 1.8 1.6 0.7 1.2 1.4 1.5 1.6 1.8 1.8 1.6 1.1 1.5 1.6 1.5 1.6 1.6 1.5 1.3 1.0 1.1 1.6 1.5 1.5 1.4 1.2 0.9 0.6 1.3 1.6 1.5 1.5 1.2 1.0 0.8 0.5 0.8 1.5 1.5 1.4 1.4 1.1 0.9 0.6 0.4 0.8 1.0 1.1 1.2 1.2 1.0 0.8 0.6 0.4 0.7 1.0 1.2 1.0 0.7 0.8 0.9 1.0 1.0 0.8 0.6 0.4 1.0 1.4 1.4 1.2 0.6 0.6 0.8 0.9 1.0 1.0 0.7 0.5 0.9 1.6 1.6 1.2 0.4 0.5 0.6 0.8 1.1 1.1 0.8 0.6 0.6 1.5 1.5 1.2 0.3 0.3 0.4 0.7 1.2 1.3 1.2 0.8 1.0 1.6 1.5 1.2 0.2 0.2 0.3 0.7 1.3 1.6 1.6 1.1 1.0 1.3 0.2 0.6 1.3 1.7 1.6 0.7 1.0 1.2 0.3 0.3 0.3 0.7 1.5 1.8 1.7 0.9 1.4 1.4 1.4 1.4 1.3 1.3 1.5 1.9 2.1 1.9 1.7 2.1 2.4 2.4 1.4 1.8 2.5 0.8 1.0 1.4 0.1 0.1 0.1 0.2 04-30-2025 Date Stamped: Expiration Date: 09-19-2023 PRO F E S S I O N A L EN GI N E E R L I C E NSE D S T A TE OF I D A H O 14893 J O SEPH W . T A F T A - EQUIPMENT SOUTH WALL D - TUNNEL WEST WALL B - OFFICE SOUTH WALL C - TUNNEL NORTH WALL G - TUNNEL EAST WALLE - EQUIPMENT WEST WALL F- OFFICE EAST WALL GRADE 100'-0" GRADE 100'-0" GRADE 100'-0" BOTTOM OF DOOR AT GRADE BOTTOM OF DOOR 1 7/8" BELOW GRADE BOTTOM OF DOOR AT GRADE BOTTOM OF DOOR 2 1/2" BELOW GRADE BOTTOM OF DOOR 2" ABOVE GRADE BOTTOM OF DOOR 8 1/2" BELOW GRADE STEEL EMBED PLATE BOTTOM OF DOOR 1 1/2" BELOW GRADE BOTTOM OF DOOR 3" ABOVE GRADE WP4WP3WP2WP1 WP5 WP13WP12WP11 WP10 WP8WP7 WP14WP8WP8WP9WP8AWP8WP8 WP16WP15 WP31WP32 WP33 WP34 WP35WP36WP37 WP41WP42 WP43 WP26WP27 WP38WP37AWP39WP40 WP37 WP38WP37CWP37BWP37WP37 19 ' - 0 12" 8'-11" 1" 10 ' - 3 12" 21 ' - 0 1 2" 8'-11"9'-11"9'-11"9'-11"7'-51 2"7'-10"7'-51 2"9'-11"9'-11"9'-11"9'-11" 1"1"1"1"1"1"1"1"1"1" 24'-0" 7' - 8 38" 5'-2" 7' - 9 58" 1'-0" 9' - 1 38" 3'-31 2" 1'-0" 4'-61 4"3'-41 2"2'-01 4" 7' - 1 0 14" 2'-0"7'-10" 9' - 9 34" 10 ' - 7 1 4" 6' - 1 1 7 8" 6' - 1 1 1 4" 5' - 0 1 2" 9'-11" 110'-11" 9'-111 2"1"9'-111 2"9'-41 4"9'-41 4"9'-41 4"9'-41 4"9'-41 4"9'-41 4"9'-41 8"9'-41 4"9'-111 2"9'-111 2"1"1"1"1"1"1"1"1"1"1" 125'-0" 7' - 0 " 4'-9"5'-21 2"4'-81 2"5'-3" 2'-2 1 16"2'-2 1 16"5'-0" 5'-0"4'-111 2"4'-111 2"5'-0" 3' - 0 1 2" 7' - 0 " 11 ' - 0 " 11 ' - 0 " 25 ' - 8 1 2" 1' - 4 12" 9' - 3 58" 3'-111 2"4'-111 2"4'-111 2"3'-111 2"8'-51 2" 21 ' - 0 1 2" 19 ' - 0 1 2" 3'-2"7'-01 2"7'-01 2"1" 4'-0"10'-6"4'-0"3'-9"3'-31 2" 1' - 8 " 7' - 4 3 8" 18'-6" 19 ' - 0 1 2" 19 ' - 0 1 2" 7' - 0 " 7' - 0 " 5' - 0 1 2" 7' - 0 " 7' - 0 " 5' - 0 1 2" 2'-51 2"1'-3"3'-111 2"1'-3" 6'-1" 1" 2'-5"7'-81 2"7'-81 2"1" 11 ' - 3 " 9' - 0 " 6'-11"12'-0"3'-3" 22'-2" 4'-0" 1" 2'-0" 10" 1" 12'-0" 1" 3'-2" 11 ' - 9 " 10" 15'-6" 4'-0"2'-6" 1" 10" 13'-6" 10" 1"1" 1" 1" 5'-10" 1' - 4 12" 19 ' - 0 12" 1"1" 1' - 4 1 2" 1' - 4 1 2" 1"1" 3' - 0 1 2" 1' - 0 " 10'-0" 7' - 0 " 3' - 0 1 2" 10'-0" 27 ' - 4 3 8" 27 ' - 4 5 8" 29 ' - 0 1 2" 2' - 0 12" TY P 2' - 0 12" TY P 2' - 0 12" TY P 9' - 2 1 2" 1" 8" 8"8" 3' - 0 " 8" 8' - 3 " 1' - 0 " 1' - 0 " 9' - 9 1 2" 412" 3' - 0 " 9' - 3 1 2" 8' - 7 1 2" 1" 3'-2"2'-11" 10 ' - 0 " 29 ' - 0 1 2" 10'-0" 3'-41 2" 6'-0" 8'-0" 8'-0" 3'-41 2" 9' - 7 5 8" 10 ' - 3 " 4'-0"4'-0"4'-0"3'-10"11"5'-1"3'-101 4"3'-9" 9'-41 8"1" 9"9"9"22'-6" 9"9"2'-31 8"10"6'-31 8" 8' - 9 " 6'-103 4"5'-0" 3' - 0 1 2" 7' - 0 " 11 ' - 0 " 1' - 0 " 6'-103 4" 16 ' - 1 12" 2' - 1 1 " 16 ' - 0 14" 3' - 0 38" 20'-0" 2'-2 1 16"2'-2 1 16"5'-0" 3' - 0 1 2" 7' - 0 " 11 ' - 0 " 1' - 0 " 16 ' - 1 0 34" 4' - 1 34" 2'-51 2" EQ EQ 2'-0" 10 1 2" 2'-51 2" 2'-0"2'-0"4'-11"2'-0"2'-0"5'-11"2'-0"2'-0"3'-51 2"2'-0"2'-0"3'-51 2"2'-0"2'-0"3'-10" STEEL EMBED PLATE 1' - 0 " TY P 2'-0"4'-0" 1' - 0 " TY P 2'-0"4'-0" 1' - 0 " TY P 4'-0"4'-0"4'-0" 2'-0"5'-111 2"2'-0" 1' - 0 " TY P 2'-0"5'-41 4"2'-0"2'-0"2'-0"5'-41 8" STEEL EMBED PLATE STEEL EMBED PLATE SHEET NO. PR O J E C T : JO B N O . : PR O J E C T M A N A G E R : CA D O P E R A T O R : TE T O N P R E S T R E S S C O N C R E T E ID A H O F A L L S , I D A H O 8 3 4 0 1 RE V . DA T E BY DE S C R I P T I O N 2 3 4 51 E2 RE X B U R G D R S H I N E CA R W A S H N 2 n d E A S T / E 2 0 0 0 N RE X B U R G , I D 8 3 4 4 0 AVBB C IF 2 1 - 3 5 6 # # # # # # # # # # 11 / 1 9 / 2 0 2 1 FE 101 MANAGER 102 CONTROL 103 HALL 104 TOILET 105 CLEAN EQUIPMENT 107 ELECTRICAL 109 WASH TUNNEL CENTERLINE OF WASH SYSTEM 108 MAT WASH REF. MAT WASH MAT WASH VE N D I N G CAB 1 1 2 2 3 3 4 4 5 6 AA BB CC DD 5 6 1 1 2 2 3 3 4 4 5 6 AA BB CC DD 5 6 04-30-2025 Date Stamped: Expiration Date: 09-19-2023 PRO F E S S I O N A L EN GI N E E R L I C E NSE D S T A TE OF I D A H O 14893 J O SEPH W . T A F T 16 ' - 5 1 2" 124'-3" 4'-10" 1" 9'-11" 1" 9'-11" 1" 9'-11" 1" 9'-11" 1" 9'-11" 1" 9'-11" 1" 9'-11" 1" 9'-11" 1"9'-111 2"1"9'-111 2" 1' - 0 1 2" 103 4"9'-01 4"2'-43 4"7'-61 4" 7' - 1 1 1 8" 7' - 5 7 8" 9' - 1 3 4" 9' - 1 3 4" 2'-11 2"7'-10"5'-8" 1' - 0 " TY P 6" TY P 2'-0" TYP 10" TYP 4'-3" TYP 2'-0" TYP 10" TYP1"1" EQ EQ 2'-0" 10 1 2" 16 ' - 5 1 2" 3'-2" 4'-0"10'-6"4'-0" 18'-6" 10" 1" 12'-0" 1" 3'-2" 9' - 9 " 10" 1" 16 ' - 1 0 " 4'-11" 19 ' - 0 1 2" 2'-0" 19 ' - 0 1 2" 4'-71 2" 1" 3'-31 2"2'-8" 5' - 0 1 2" 1' - 4 1 2" 10 ' - 8 " 7' - 0 " 6' - 1 1 " 1" 1" 12'-8" H - TUNNEL INTERIOR WALL GRADE 100'-0" GRADE 100'-0" 2' - 0 12" TY P 2' - 0 12" TY P 28 ' - 1 1 " 1'-4"7'-21 2" 1"9'-111 2"9'-21 2"1" 19 ' - 8 1 4" 18 ' - 0 3 8" 18 ' - 0 1 8" 16 ' - 5 7 8" 7' - 2 1 4" 3'-41 2" 3'-91 4" 1' - 0 " 7' - 9 1 2" 8'-0" 8" 3' - 0 " BOTTOM OF DOOR AT GRADE I - TUNNEL INTERIOR WALL J - OFFICE WEST WALL K - OFFICE NORTH WALL BOTTOM OF DOOR AT GRADE 10 ' - 3 " STEEL EMBED PLATE 4'-0"4'-0"4'-0"3'-10"11"5'-1"4'-5" 6' - 9 1 4" 6' - 8 1 4" 6' - 1 1 1 4" 7' - 0 1 4" 3'-9" BOTTOM OF DOOR 3" BELOW GRADE BOTTOM OF DOOR 3 1/2" BELOW GRADE WP6 WP17A WP17 WP18WP19 WP20WP20WP20WP20WP20WP20AWP21WP22WP23 WP24WP25 WP28WP29 WP30 WP44 WP45 WP46 19'-3" 10" 1' - 0 " TY P 6" TY P 2'-0" TYP 10" TYP 4'-3" TYP 2'-0" TYP 10" TYP 16 ' - 4 1 2" 2' - 8 " 61 2" EQ EQ 1' - 0 " 2'-0"5'-111 2" 1' - 0 " TY P 2'-0"2'-0"5'-21 2"2'-0" STEEL EMBED PLATE (PLATES ONE BOTH SIDES OF PANEL, OFF SET BACK SIDE PLATE BY 6") 2'-0"4'-8"2'-0"4'-0" 1' - 0 " TY P SHEET NO. PR O J E C T : JO B N O . : PR O J E C T M A N A G E R : CA D O P E R A T O R : TE T O N P R E S T R E S S C O N C R E T E ID A H O F A L L S , I D A H O 8 3 4 0 1 RE V . DA T E BY DE S C R I P T I O N 2 3 4 51 E3 RE X B U R G D R S H I N E CA R W A S H N 2 n d E A S T / E 2 0 0 0 N RE X B U R G , I D 8 3 4 4 0 AVBB C IF 2 1 - 3 5 6 # # # # # # # # # # 11 / 1 9 / 2 0 2 1 FE 101 MANAGER 102 CONTROL 103 HALL 104 TOILET 105 CLEAN EQUIPMENT 107 ELECTRICAL 109 WASH TUNNEL CENTERLINE OF WASH SYSTEM 108 MAT WASH REF. MAT WASH MAT WASH VE N D I N G CAB 1 1 2 2 3 3 4 4 5 6 AA BB CC DD 5 6 1 1 2 2 3 3 4 4 5 6 AA BB CC DD 5 6 04-30-2025 Date Stamped: Expiration Date: 09-19-2023 PRO F E S S I O N A L EN GI N E E R L I C E NSE D S T A TE OF I D A H O 14893 J O SEPH W . T A F T WF1 DETAIL REF: NO SCALE 112" TY P 11 2" TYP A PLANA 1/2" THICK STEEL BASE PLATE (4) 1/2" DIA. x 8" LONG HEADED STUD 1'-0" 1' - 0 " WF2 DETAIL REF:NO SCALE 1/4 4 EMBEDDED PLATE 1" DIA. x 5" LONG SOLID ROD WF3 DETAIL REF:NO SCALE 1/4 4 1" DIA. x 5" LONG SOLID ROD A SECTIONA WF5 DETAIL REF:NO SCALE 1/4 4 EMBEDDED PLATE (2) 1" DIA. x 5" LONG SOLID ROD EMBEDDED PLATE 3/8"x3"x8" PLATE TYP 1/4 TYP 1/4 1 1/2" GROUT 1/44 1/4 4 8" 1'-0" 212" 212" 3" 11 2"11 2"9" 1' - 4 " MI N CO1 C8x13.75 (4) #4 DBA C8x13.75 (4) #4 DBA 2" EQ EQ 6" 112" TY P 3"6" 6" 3/8" THICK STEEL PLATE (2) 1/2"Ø HEADED STUDS 3/8" THICK STEEL PLATE (2) 1/2"Ø HEADED STUDS CO2 RL1 - QL116G RL2 - QL119G EP1 - EMBED PLATE 11 2" TYP 9" 1/2" THICK STAINLESS STEEL PLATE (2) 1/2"Ø HEADED STUDS 5" TY P 10 " 5" 1'-0" (2) 1/2"Ø HEADED STUDS 1/2" THICK STAINLESS STEEL PLATE 4" EQ EQ 6" 112" TY P 3" 4" 4" 3/8" THICK STEEL PLATE (2) 1/2"Ø x 12" BENT DBA 3/8" THICK STEEL PLATE (2) 1/2"Ø x 12" BENT DBA CO3 10" 1' - 2 " #6 R1 #6 R2 10" 4" 1'-0 " 11" 3" (2) #3 R3 4 5 ° EQEQ 8" 1'-0" 212" 212" 3" 11 2"11 2"9" 1' - 0 " MI N CO4 C8x13.75 (4) #4 DBA C8x13.75 (4) #4 DBA No. REQUIRED - 295 No. REQUIRED - 123 No. REQUIRED - 229 No. REQUIRED - 97 No. REQUIRED - 300 No. REQUIRED - 35 No. REQUIRED - 295 No. REQUIRED - 590 No. REQUIRED - 10 No. REQUIRED - 14 No. REQUIRED - 107 EP2 - EMBED PLATE 5" 4" (1) 1/2"Ø HEADED STUDS 1/4" THICK STEEL PLATE No. REQUIRED - 105 2'-0" 7' - 0 " #4 R4 No. REQUIRED - 2 3'-6" 11 ' - 7 " #4 R5 No. REQUIRED - 2 #4 R6 No. REQUIRED - 6 5'-0" 1' - 1 " #4 R7 No. REQUIRED - 2 5'-6" 8" #4 R8 No. REQUIRED - 2 3'-6" 8" 4'-7" 7' - 0 " #4 R9 No. REQUIRED - 2 1'-6" 1'-6 " #6 R10 No. REQUIRED - 2 90.00° #4 R6 No. REQUIRED - 6 8'-0" 2' - 8 " 4" EQ EQ 6" 112" TY P 3" 4" 4" 3/8" THICK STAINLESS STEEL PLATE (2) 1/2"Ø x 12" BENT DBA 3/8" THICK STAINLESS STEEL PLATE (2) 1/2"Ø x 12" BENT DBA CO3S No. REQUIRED - 4 1/2" THICK STEEL PLATE 6" EP3 - EMBED PLATE No. REQUIRED - 2 1'-2" 1/2" THICK STAINLESS STEEL PLATE 6" EP3S - EMBED PLATE No. REQUIRED - 2 1'-2" EMBEDDED PLATE EMBEDDED PLATE 1/4 4 EP4 - EMBED PLATE 11 2" TYP7" 1/2" THICK STEEL PLATE (2) 5/8"Ø HEADED STUDS 3" TY P 6" 5" 10" (2) 5/8"Ø HEADED STUDS 1/2" THICK STEEL PLATE No. REQUIRED - 8 g SHEET NO. PR O J E C T : JO B N O . : PR O J E C T M A N A G E R : CA D O P E R A T O R : TE T O N P R E S T R E S S C O N C R E T E ID A H O F A L L S , I D A H O 8 3 4 0 1 RE V . DA T E BY DE S C R I P T I O N 2 3 4 51 E4 RE X B U R G D R S H I N E CA R W A S H N 2 n d E A S T / E 2 0 0 0 N RE X B U R G , I D 8 3 4 4 0 AVBB C IF 2 1 - 3 5 6 # # # # # # # # # # 11 / 1 9 / 2 0 2 1 FE 101 MANAGER 102 CONTROL 103 HALL 104 TOILET 105 CLEAN EQUIPMENT 107 ELECTRICAL 109 WASH TUNNEL CENTERLINE OF WASH SYSTEM 108 MAT WASH REF. MAT WASH MAT WASH VE N D I N G CAB 1 1 2 2 3 3 4 4 5 6 AA BB CC DD 5 6 1 1 2 2 3 3 4 4 5 6 AA BB CC DD 5 6 04-30-2025 Date Stamped: Expiration Date: 09-19-2023 PRO F E S S I O N A L EN GI N E E R L I C E NSE D S T A TE OF I D A H O 14893 J O SEPH W . T A F T 04-30-2025 Date Stamped: Expiration Date: 09-19-2023 PRO F E S S I O N A L EN GI N E E R L I C E NSE D S T A TE OF I D A H O 14893 J O SEPH W . T A F T 04-30-2025 Date Stamped: Expiration Date: 09-19-2023 PRO F E S S I O N A L EN GI N E E R L I C E NSE D S T A TE OF I D A H O 14893 J O SEPH W . T A F T 04-30-2025 Date Stamped: Expiration Date: 09-19-2023 PRO F E S S I O N A L EN GI N E E R L I C E NSE D S T A TE OF I D A H O 14893 J O SEPH W . T A F T 04-30-2025 Date Stamped: Expiration Date: 09-19-2023 PRO F E S S I O N A L EN GI N E E R L I C E NSE D S T A TE OF I D A H O 14893 J O SEPH W . T A F T ’ ’ ’ ’ – 11'-113 4 " 2' - 0 " 11'-113 4 " 8" FACE VIEW SIDE VIEW BOTTOM VIEW 5/  CO CCO 5/ 8" 5/ COCO CO 2" 2" 4" 1' - 3 1 2" 414 " 3" 21 2" #6 BAR21 2" CO 3'-4" 1'-81 2"LIFTING 4'-111 4"2'-0" 6" LI F T I N G 9" 9" 1'-11"8'-41 4" 1'-01 2" CO 2" CO 414" 1' - 0 " 1' - 0 " 2" CO 2 11 1 2" 1' - 0 1 2" CO N C R E T E CO L O R : G R E Y TYPE: RELEASE: 28 DAY: VOLUME: WEIGHT: ST R A N D LO W L A X ME S H CA S T I N M A T E R I A L RE B A R PL A I N A S T M A 6 1 5 - 6 0 DA T E JO B FI N I S H TETON PRESTRESS CONCRETE MARK:(1) REQ'D DECK: ENDS: (2) LAYERS OF 6x6-W6.0xW6.0 CO1 CO2 RL1 RL2 #6 x11'-8"4 1 3 2 1 CO3 2 WP4 9/7/2021 DR. SHINE CARWASH STEEL TROWEL FORM NORMAL 4000 PSI 6000 PSI 16.1 FT3 2,410 LBS # # # # # 3" 21 2" #6 BAR21 2" 1' - 4 " 434" 434 " CO1 9'-13 4" 2' - 1 1 2" 8" )$C( 9,(: 6,'( 9,(: %O77O0 9,(: (2) CO2 RL2 1'-81 2"1'-81 2"5'-83 4 " 834" 11 3 4" 5" 1' - 0 3 4" 1' - 0 3 4" RL2 RL1 CO1 9'-13 4" 8" RL1 CO 1 LIFTING LI F T I N G CO2 7'-6"1'-73 4" 2" CO 2 2" 2" 4" CO N C R E T E CO L O R : G R E Y TYPE: RELEASE: 28 DAY: VOLUME: WEIGHT: ST R A N D LO W L A X ME S H CA S T I N M A T E R I A L RE B A R PL A I N A S T M A 6 1 5 - 6 0 DA T E JO B FI N I S H TETON PRESTRESS CONCRETE MARK:(1) REQ'D DECK: ENDS: (2) LAYERS OF 6x6-W6.0xW6.0 CO1 CO2 RL1 RL2 1 3 2 1 #6 x 8'-11"4 WP23 10/20/2021 DR. SHINE CARWASH STEEL TROWEL FORM NORMAL 4000 PSI 6000 PSI 12.9 FT3 1,940 LBS # # # # # CO2 16'-57 8" 9' - 2 1 2" 7'-23 4 " 8" 8" 5' - 1 1 " F$CE 9IEW SIDE 9IEW %OTTO0 9IEW 18'-01 8" 1' - 3 " LI F T I N G 1' - 3 " 6' - 8 1 2" 1'-81 2" 1'-2" LIFTING CO2 13'-03 4"1'-81 2" 10'-107 8" 8' - 9 1 2" CO 2 5" 6"6" #6 R2 #6 R1 (2) #3 R3 2" CO 2 CO2 CO2 RL1RL1 RL2 10'-93 8" 714" (8 ) S P @ 1 ' - 0 " = 8 ' - 0 " 714 " (2) #4 x 9'-0" DOWELS 1'-2"7'-51 8"5'-0" #6 R 1 #6 R 2 #3 R 3 6" 4'-5" 4'-5" (2) CO2 4" CO2 3" 21 2" 1 2"Ø STRAND21 2" 2" 2" 4" 1' - 4 " 334" 1' - 4 " 334" 9' - 2 1 2" (2) CO2 CO2 2' - 0 " 2' - 0 " 6" 1'-0"TYP 6" 4' - 2 1 2" EP2 OPPOSITE SIDE EP2 OPPOSITE SIDE 4" CO3 CO3S61 2" 7'-01 4" 714" 2' - 8 " 2' - 8 " 2' - 8 " 714 " EP4 OPPOSITE SIDE CO N C R E T E CO L O R : G R E Y TYPE: RELEASE: 28 DAY: VOLUME: WEIGHT: ST R A N D LO W L A X ME S H CA S T I N M A T E R I A L RE B A R PL A I N A S T M A 6 1 5 - 6 0 DA T E JO B FI N I S H TETON PRESTRESS CONCRETE MARK:(1) REQ'D DECK: ENDS: (2) LAYERS OF 6x6-W6.0xW6.0 CO2 RL1 RL2 9 4 2 #4 x 9'-0"2 #6 R1 9 #6 R2 9 #3 R3 18 EP2 4 CO3 1 CO3S 1 EP4 4 WP24 10/20/2021 DR. SHINE CARWASH STEEL TROWEL FORM NORMAL 4000 PSI 6000 PSI 106.3 FT3 15,950 LBS (8) 1/2"∅ 270 K # # # # 18'-03 8" 9' - 1 1 1 2" 8" 8" 9' - 1 1 1 2" F$CE 9IEW SIDE 9IEW %OTTO0 9IEW 19'-81 4" 534 " (9 ) S P @ 1 ' - 0 " = 9 ' - 0 " 534" (2) #4 x 9'-9" DOWELS #6 R 1 #6 R 2 #3 R 3 7'-23 4 " 6"6" #6 R2 #6 R1 (2) #3 R3 2" CO 2 CO2 CO2 RL1RL1 12'-51 2" 1' - 3 " LI F T I N G 1' - 3 " 7' - 5 1 2" 1'-81 2"LIFTING14'-73 8"1'-81 2" 1'-2" 7'-53 8"5'-0" 9'-11 4"5'-0" 6" CO2 5" CO 2 9' - 2 1 2"#6 x 9'-9" CO2 CO2 4'-5" 1'-2"4'-5" (2) CO2 (2) CO2 4" 2" 2" 4" 3" 21 2" 1 2"Ø STRAND21 2" 1' - 4 " 334 " 6' - 8 " 1' - 4 " 334 " CO2RL2 2' - 0 " 6" 2' - 0 " 1'-0"TYP 6" 4' - 1 1 1 2" EP2 OPPOSITE SIDE EP2 OPPOSITE SIDE CO3 4" CO3S61 2" 7'-01 4" 11 3 4 " 2' - 8 " 2' - 8 " 2' - 8 " EP4 OPPOSITE SIDE 11 3 4 " CO N C R E T E CO L O R : G R E Y TYPE: RELEASE: 28 DAY: VOLUME: WEIGHT: ST R A N D LO W L A X ME S H CA S T I N M A T E R I A L RE B A R PL A I N A S T M A 6 1 5 - 6 0 DA T E JO B FI N I S H TETON PRESTRESS CONCRETE MARK:(1) REQ'D DECK: ENDS: (2) LAYERS OF 6x6-W6.0xW6.0 CO2 RL1 RL2 10 4 2 #4 x 9'-9"2 #6 R1 10 #6 R2 10 #3 R3 20 #6 x 9'-9"1 EP2 4 CO3 1 CO3S 1 EP4 4 WP25 10/20/2021 DR. SHINE CARWASH STEEL TROWEL FORM NORMAL 4000 PSI 6000 PSI 125.1 FT3 18,770 LBS (8) 1/2"∅ 270 K # # # # 1' - 4 " 334" 19'-01 2" 8" 8" F$CE 9IEW SIDE 9IEW %OTTO0 9IEW 7'-0"7' - 8 1 2" 19'-01 2" 7'-0"5'-01 2"4' - 0 " (2) #4 x 2'-0" DOWELS CO2 CO2 15'-5"1'-81 2" 5'-01 2" 11 1 2" LIFTING CO2 CO1 4'-111 4"1'-0" 1' - 3 " LI F T I N G 1'-11" 11 1 2" 5' - 9 1 2" 3" 21 2" 1 2"Ø STRAND21 2" 1' - 4 " 334 " 4' - 5 " CO1 1' - 3 " RL2 5' - 2 1 2" RL1 CO1 RL2 RL1 CO2 2" CO 2 1' - 3 " 2' - 5 1 2" #6 x 7'-6" (2) #4 x 7'-6" 1' - 4 " 2' - 6 1 2" 2' - 6 " 1' - 4 " 2'-97 8" 2'-103 8" 2'-11" EP2 FOLLOW ROOF SLOPE 4'-113 4"3'-1" 4'-3"7'-31 2"7'-6" CO N C R E T E CO L O R : G R E Y TYPE: RELEASE: 28 DAY: VOLUME: WEIGHT: ST R A N D LO W L A X ME S H CA S T I N M A T E R I A L RE B A R PL A I N A S T M A 6 1 5 - 6 0 DA T E JO B FI N I S H TETON PRESTRESS CONCRETE MARK:(1) REQ'D DECK: ENDS: (2) LAYERS OF 6x6-W6.0xW6.0 CO1 CO2 RL1 RL2 #6 x 7'-6"1 2 6 4 2 #4 x 2'-0"8 #4 x 7'-6"2 EP2 6 WP26 10/20/2021 DR. SHINE CARWASH STEEL TROWEL FORM NORMAL 4000 PSI 6000 PSI 79.2 FT3 11,870 LBS (8) 1/2"∅ 270 K # # # # CO 2 7'-0" 8" 8" 12 ' - 8 " F$CE 9IEW SIDE 9IEW %OTTO0 9IEW 12 ' - 8 " 4'-4" 6" 6"6" #6 R2 #6 R1 (2) #3 R3 RL2 RL1 1' - 3 " 1' - 3 " (1 2 ) S P @ 1 ' - 0 " = 1 2 ' - 0 " #6 R 1 #6 R 2 #3 R 3 4" CO3 4" (2) #4 x 12'-6" DOWELS LIFTING CO3 LI F T I N G RL2 CO3 OPPOSITE SIDE 2'-8" 10 ' - 2 " 1'-11"1'-11" 2'-9"4'-3" 2' - 2 " 9' - 0 " 1' - 6 " CO2 2"CO2 3'-2" (2) CO2 (2) CO2 6" 2" 3" 212" 1 2"Ø S T R A N D 212"33 4"1'-4"33 4 "1'-4"3'-81 4 " C03 C03 2' - 0 " 2' - 0 " 4' - 0 " 4' - 8 " CO N C R E T E CO L O R : G R E Y TYPE: RELEASE: 28 DAY: VOLUME: WEIGHT: ST R A N D LO W L A X ME S H CA S T I N M A T E R I A L RE B A R PL A I N A S T M A 6 1 5 - 6 0 DA T E JO B FI N I S H TETON PRESTRESS CONCRETE MARK:(1) REQ'D DECK: ENDS: (2) LAYERS OF 6x6-W6.0xW6.0 CO3 RL1 RL2 2 4 2 #4 x 12'-6"2 #6 R1 13 #6 R2 13 #3 R3 26 CO2 4 EP2 3 WP30 10/20/2021 DR. SHINE CARWASH STEEL TROWEL FORM NORMAL 4000 PSI 6000 PSI 142.5 FT3 21,380 LBS (8) 1/2"∅ 270 K # # # # CO3 29'-01 2" 8" 8" F$CE 9,EW S,DE 9,EW %O77O0 9,EW 2' - 1 1 " 10'-0"19'-01 2" 1' - 7 " 10 " 17'-91 2"11'-3" 3" 212" 1 2"Ø S T R A N D 212" 1'-4"33 4"3'-71 2" CO1 1'-4"33 4" 1'-81 2" 7'-6" 11 1 2" LIFTING CO2 / CO3 CO1 11 1 2" CO 1 5' - 0 " C02 7'-31 2"4'-3" (2) #4 x 2'-0" DOWELSCO2 1'-1"7'-0"2'-1"6'-71 2"1'-0" 1' - 7 " LI F T I N G 25'-5"1'-11" RL2 CO2 RL1 CO1 RL1 2" CO 2 CO3 CO3 CO2 C02 6" 3' - 1 " 7'-6"2'-103 4"4'-5"9'-11 4 "5'-11 2" RL2 RL2 (1) #6 R10 (1) #6 R10 13 8"CO3 1' - 0 " 2' - 1 " 2' - 0 " 1' - 0 " 2'-65 8" 2'-71 8" 2'-73 4 "EP2 FOLLOW ROOF SLOPE CO N C R E T E CO L O R : G R E Y TYPE: RELEASE: 28 DAY: VOLUME: WEIGHT: ST R A N D LO W L A X ME S H CA S T I N M A T E R I A L RE B A R PL A I N A S T M A 6 1 5 - 6 0 DA T E JO B FI N I S H TETON PRESTRESS CONCRETE MARK:(1) REQ'D DECK: ENDS: (2) LAYERS OF 6x6-W6.0xW6.0 CO1 CO2 CO3 RL1 RL2 2 7 4 2 #4 x 2'-0"4 4 #6 R10 2 EP2 3 WP31 10/20/2021 DR. SHINE CARWASH STEEL TROWEL FORM NORMAL 4000 PSI 6000 PSI 157.6 FT3 23,640 LBS (8) 1/2"∅ 270 K # # # # 8" 8" FACE VIEW SIDE VIEW BOTTOM VIEW 2' - 5 " 17'-91 2" 29'-01 2" 11'-3" 10 " 1' - 4 " CO 1   [   DOWE/S CO 11 1 2" CO 1'-1"7'-0"2'-1"6'-71 2"1'-0" 1'-11"25'-5"1'-81 2" 10'-0"7'-31 2"7'-6" 1' - 2 1 2" 1' - 2 1 2" CO 29'-01 2" 5/ 5/ CO 5/ 2" CO 2 CO CO 6" 11 1 2" C024'-3"   5 CO2 3" 21 2" 1 2"Ø STRAND21 2" 1' - 4 " 334 " 1' - 7 1 4 " 13 8" CO 8" 1' - 1 " 8" 12'-17 8" 12'-21 8" E3 FO//OW 5OOF S/O3E CO N C R E T E CO L O R : G R E Y TYPE: RELEASE: 28 DAY: VOLUME: WEIGHT: ST R A N D LO W L A X ME S H CA S T I N M A T E R I A L RE B A R PL A I N A S T M A 6 1 5 - 6 0 DA T E JO B FI N I S H TETON PRESTRESS CONCRETE MARK:(1) REQ'D DECK: ENDS: (2) LAYERS OF 6x6-W6.0xW6.0 CO1 CO2 RL1 RL2 2 8 2 1 #6 R10 1 #4 x 2'-0"2 EP2 2 WP32 10/20/2021 DR. SHINE CARWASH STEEL TROWEL FORM NORMAL 4000 PSI 6000 PSI 52.5 FT3 7,880 LBS (4) 1/2"∅ 270 K # # # # FACE VIEW SIDE VIEW BOTTOM VIEW 3' - 1 0 1 4" 5' - 1 " 5" 12'-31 2" 8" 9' - 4 1 4" 1' - 4 " 334 " 8" 21'-01 2" #6 R 1 #6 R 2 #3 R 3 11 1 2" CO 1 7' - 5 1 4" CO CO11 1 2" 1'-81 2" 7'-6" LIFTING CO27'-31 2"6'-3" 1' - 3 " 5/ 1' - 3 " LI F T I N G 6' - 1 0 1 4" 17'-5"1'-11" 5/ 3" 21 2" 1 2"Ø STRAND21 2" 1' - 4 " 334" 6' - 0 3 4" CO 6" 8" (6 ) S P @ 1 ' - 0 " = 6 ' - 0 "   [   DOWE/S 218"   [   DOWE/S 8" 6"6" 3'-103 4"17'-13 4" 5/ CO 2" CO 2 CO  5  5   5 5/ 5/ (1 ) S P @ 1 ' - 0 " = 1 ' - 0 " 1' - 7 1 8"   [   6' - 3 1 4 " 10 " 2' - 3 " COCO 2' - 6 " CO 2' - 0 " 5' - 4 1 4" 2' - 0 " 1'-0"TYP E3 CO N C R E T E CO L O R : G R E Y TYPE: RELEASE: 28 DAY: VOLUME: WEIGHT: ST R A N D LO W L A X ME S H CA S T I N M A T E R I A L RE B A R PL A I N A S T M A 6 1 5 - 6 0 DA T E JO B FI N I S H TETON PRESTRESS CONCRETE MARK:(1) REQ'D DECK: ENDS: (2) LAYERS OF 6x6-W6.0xW6.0 CO1 CO2 RL1 RL2 #6 x 9'-2"1 2 4 4 2 #4 x 6'-0"2 #6 R1 9 #6 R2 9 #3 R3 18 #4 x 2'-11"2 CO2 2 EP1 2 EP2 2 WP37A 10/20/2021 DR. SHINE CARWASH STEEL TROWEL FORM NORMAL 4000 PSI 6000 PSI 131.2 FT3 19,670 LBS (8) 1/2"∅ 270 K # # # # (2) #4 x 22'-3" 24'-0" 6' - 1 1 7 8" 3'-03 8" 8" 8" 24 ' - 0 " F$CE 9IEW SIDE 9IEW %OTTO0 9IEW 6"6" 9"9" 1' - 0 " 4' - 1 1 7 8" 1' - 0 " 1'-3"9'-3"3'-0"9'-3"1'-3"CO2 2'-81 2"18'-7"2'-81 2" RL2 CO3 (2) CO2(2) CO2 RL2 #6 R2 #6 R1 (2) #3 R3 RL1 LIFTING C0 3 RL1 RL1 CO2 CO2 2"CO2 4" C0 2 2" CO3 2" (2) CO2 (2) CO2 CO3 CO3 2" (22) SP @ 1'-0" = 22'-0"3"3" C03C03 3'-113 8" 1'-4"33 4 "1'-4"33 4 "3'-81 4" C02 3" 212" 212" #6 B A R 1' - 0 " TY P 2'-0"4'-0"4'-0"4'-0"4'-0"4'-0"2'-0" EP2 CO N C R E T E CO L O R : G R E Y TYPE: RELEASE: 28 DAY: VOLUME: WEIGHT: ST R A N D LO W L A X ME S H CA S T I N M A T E R I A L RE B A R PL A I N A S T M A 6 1 5 - 6 0 DA T E JO B FI N I S H TETON PRESTRESS CONCRETE MARK:(1) REQ'D DECK: ENDS: (2) LAYERS OF 6x6-W6.0xW6.0 CO2 RL1 RL2 8 4 2 #6 R1 23 #6 R2 23 #3 R3 46 CO3 4 #4x22'-3"2 #6x23'-8"8 EP2 6 WP5 9/7/2021 DR. SHINE CARWASH STEEL TROWEL FORM NORMAL 4000 PSI 6000 PSI 111.6 FT3 16,740 LBS # # # # # F$CE 9IEW SIDE 9IEW %OTTO0 9IEW 19'-01 2" 7' - 5 1 2" 8" 8"4'-3"1'-01 2" 1' - 0 " 16'-11 2"2'-11" 6" 6"6" CO1 LIFTING CO2 1'-81 2" 11 1 2" CO1 1' - 3 " #6 R 1 #6 R 2 #3 R 3 234" CO2 (2) #4 x 7'-3" DOWELS 11 1 2" CO 1 RL2 1' - 3 " LI F T I N G 4' - 1 1 1 2" 234 "6" 8'-45 8" 1'-0" 7'-03 8" #6 x 7'-3" DOWEL 7'-6"7'-31 2"4'-3" 6" 1' - 4 " 334 " 3" 21 2" 1 2"Ø STRAND21 2" 1' - 4 " 334" CO1 5' - 2 " #6 R2 #6 R1 (2) #3 R3 RL2 RL1 CO2 RL1 CO1 CO2 (2) #4 x 2'-0" DOWELS 1'-11" 2" CO 2 CO2 (7 ) S P @ 1 ' - 0 " = 7 ' - 0 " 3'-83 8"9'-05 8" 1' - 3 " EP2 2' - 0 " 3' - 5 1 2" TYP1'-0" 2' - 0 " 2' - 3 1 4 " 2' - 0 " 2' - 3 1 4" 101 2" CO N C R E T E CO L O R : G R E Y TYPE: RELEASE: 28 DAY: VOLUME: WEIGHT: ST R A N D LO W L A X ME S H CA S T I N M A T E R I A L RE B A R PL A I N A S T M A 6 1 5 - 6 0 DA T E JO B FI N I S H TETON PRESTRESS CONCRETE MARK:(1) REQ'D DECK: ENDS: (2) LAYERS OF 6x6-W6.0xW6.0 CO1 CO2 RL1 RL2 #6 x 7'-3"1 2 6 4 2 #4 x 7'-3"2 #6 R1 8 #6 R2 8 #3 R3 16 #4 x 2'-0"2 EP2 2 WP9 10/15/2021 DR. SHINE CARWASH STEEL TROWEL FORM NORMAL 4000 PSI 6000 PSI 101.2 FT3 15,180 LBS (8) 1/2"∅ 270 K # # # # 9'-13 8" 7' - 1 0 " 8" 8" 7' - 1 0 " F$CE 9IEW SIDE 9IEW %OTTO0 9IEW 6'-23 8"2'-11" 6" 6"6" 1' - 3 " 5' - 4 " RL2 1' - 3 " #6 R 1 #6 R 2 #3 R 3 5" (7 ) S P @ 1 ' - 0 " = 7 ' - 0 " (2) #4 x 7'-8" DOWELS 5" 1'-81 2"LIFTING5'-57 8"1'-11" 1'-0"CO23'-103 8"4'-3" 6" 6' - 1 0 " 6" RL2 RL1 #6 R2 #6 R1 (2) #3 R3 RL1 2" CO 2 3" 212" # 6 B A R 212" 1'-4"33 4 " CO2 CO2 2"CO2 1'-4"33 4 " TYP1'-0" 3' - 1 0 " 2' - 0 " EP2 2' - 0 " CO N C R E T E CO L O R : G R E Y TYPE: RELEASE: 28 DAY: VOLUME: WEIGHT: ST R A N D LO W L A X ME S H CA S T I N M A T E R I A L RE B A R PL A I N A S T M A 6 1 5 - 6 0 DA T E JO B FI N I S H TETON PRESTRESS CONCRETE MARK:(1) REQ'D DECK: ENDS: (2) LAYERS OF 6x6-W6.0xW6.0 CO2 RL1 RL2 6 4 2 #4 x 7'-8"2 #6 R1 8 #6 R2 8 #3 R3 16 #6 x 7'-8"8 EP2 2 WP10 10/15/2021 DR. SHINE CARWASH STEEL TROWEL FORM NORMAL 4000 PSI 6000 PSI 47.2 FT3 7,080 LBS # # # # # 9' - 1 38" 7'-10" 1'-3"5'-4" RL 2 1'-3" #6 R1 #6 R2 #3 R3 5"(7) SP @ 1'-0" = 7'-0" (2 ) # 4 x 7 ' - 8 " D O W E L S 5" 1' - 8 12" LI F T I N G 5' - 5 78" 1' - 1 1 " 1' - 0 " CO 2 3' - 1 0 38" 4' - 3 " 6"6'-10"6" CO 2 CO 2 TY P 1' - 0 " 3'-10"2'-0" EP 2 2'-0" 8" 8" F$CE 9IEW SIDE 9IEW %OTTO0 9IEW 7'-83 8"9'-115 8" 3' - 3 1 2" 1'-41 2" 16'-11 2"2'-11" 6" 6"6" 3" 21 2" 1 2"Ø STRAND21 2" 1' - 4 " 334 " 6' - 8 " 6" 1' - 4 " 334" 2" CO 2 7' - 5 1 2" 9'-23 8"9'-101 8" 1' - 0 " LIFTING CO4 81 4" 11 1 2" 1' - 3 " #6 R 1 #6 R 2 #3 R 3 234" 11 1 2" CO 4 1' - 3 " 4' - 1 1 1 2" 234 " 6" 9'-17 8"1'-0"3'-113 8"2'-4" 9'-7"5'-21 2"4'-3" 1'-11" 6' - 6 1 2" CO2 (7 ) S P @ 1 ' - 0 " = 7 ' - 0 " 19'-01 2" 1'-01 2" CO1 #6 R2 #6 R1 (2) #3 R3 RL2 RL1 CO2 RL1 CO1 CO4 CO4 CO2(2) #4 x 7'-3" DOWELS RL2 #6 x 7'-3" DOWEL CO2 (2) #4 x 2'-0" DOWELS (2) #4 x 2'-0" DOWELS (2) #4 x 2'-0" DOWELS (2) #4 R6 (2) #4 x 8'-3" EP2 2' - 0 " TYP1'-0" 3' - 5 1 2" 2' - 0 " CO N C R E T E CO L O R : G R E Y TYPE: RELEASE: 28 DAY: VOLUME: WEIGHT: ST R A N D LO W L A X ME S H CA S T I N M A T E R I A L RE B A R PL A I N A S T M A 6 1 5 - 6 0 DA T E JO B FI N I S H TETON PRESTRESS CONCRETE MARK:(1) REQ'D DECK: ENDS: (2) LAYERS OF 6x6-W6.0xW6.0 CO4 CO2 RL1 RL2 #6 x 7'-3"1 2 6 4 2 #4 x 8'-3"2 #6 R1 8 #6 R2 8 #3 R3 16 #4 x 2'-0"6 #4 R6 2 EP2 2 WP12 10/15/2021 DR. SHINE CARWASH STEEL TROWEL FORM NORMAL 4000 PSI 6000 PSI 84.3 FT3 12,650 LBS (8) 1/2"∅ 270 K # # # # 8'-9" 8' - 1 1 " 8" 8" F$CE 9IEW SIDE 9IEW %OTTO0 9IEW 10'-31 2" 2' - 0 " 4' - 1 1 1 2" 16'-11 2"2'-11" 6" 6"6" 6' - 4 1 2" CO1 1' - 3 " (8 ) S P @ 1 ' - 0 " = 8 ' - 0 " #6 R 1 #6 R 2 #3 R 3 512" CO2 (2) #4 x 8'-9" DOWELS 11 1 2" CO 1 RL2 1' - 3 1 4 " 512" 4'-3"2'-0"6" 1'-81 2"15'-5"1'-11" 4'-3"7'-31 2"7'-6" (2) #4 x 2'-0" DOWELS CO2 3" 21 2" 1 2"Ø STRAND21 2" 1' - 4 " 334 " 5' - 7 1 2" CO1 1' - 4 " 334 " #6 x 8'-9" DOWEL RL1 CO1 #6 R2 #6 R1 (2) #3 R3 RL2 RL1 CO2 2" CO 2 2'-0" (2) #4 8'-9" (2) #4 13'-0"1' - 0 " 6" EP2 2' - 0 " 4' - 1 1 " TYP1'-0" 2' - 0 " CO N C R E T E CO L O R : G R E Y TYPE: RELEASE: 28 DAY: VOLUME: WEIGHT: ST R A N D LO W L A X ME S H CA S T I N M A T E R I A L RE B A R PL A I N A S T M A 6 1 5 - 6 0 DA T E JO B FI N I S H TETON PRESTRESS CONCRETE MARK:(1) REQ'D DECK: ENDS: (2) LAYERS OF 6x6-W6.0xW6.0 CO1 CO2 RL1 RL2 #6 x 8'-9"1 2 5 3 2 #4 x 8'-9"4 #6 R1 9 #6 R2 9 #3 R3 18 #4 x 2'-0"2 #4 x 13'-0"2 EP2 2 WP13 10/15/2021 DR. SHINE CARWASH STEEL TROWEL FORM NORMAL 4000 PSI 6000 PSI 79.0 FT3 11,850 LBS (8) 1/2"∅ 270 K # # # # 19'-01 2" 8' - 1 1 " F$CE 9IEW SIDE 9IEW %OTTO0 9IEW 8" 16'-11 2"2'-11" 6" 6"6" RL1 CO1 #6 R2 #6 R1 (2) #3 R3 RL2 RL1 CO2 2" CO 2 3" 21 2" 1 2"Ø STRAND21 2" 1' - 4 " 434 " 5' - 7 " CO1 1' - 4 " 334" 8'-9"10'-31 4 " 2' - 0 " 4' - 1 1 1 2" 6' - 5 " CO1 1' - 3 " (8 ) S P @ 1 ' - 0 " = 8 ' - 0 " #6 R 1 #6 R 2 #3 R 3 512" CO3(2) #4 x 8'-9" DOWELS 11 1 2" CO 1 RL2 1' - 3 " 512" 4'-3"2'-0"6" 1'-81 2"15'-5"1'-11" 4'-3"7'-31 2"7'-6" (2) #4 x 2'-0" DOWELS CO2 #6 x 8'-9" DOWEL LIFTING CO3 2'-0" 1' - 0 " 2" (2) #4 x 13'-0" (2) #4 8'-9" 8"6" EP2 2' - 0 " 4' - 1 1 " TYP1'-0" 2' - 0 " CO N C R E T E CO L O R : G R E Y TYPE: RELEASE: 28 DAY: VOLUME: WEIGHT: ST R A N D LO W L A X ME S H CA S T I N M A T E R I A L RE B A R PL A I N A S T M A 6 1 5 - 6 0 DA T E JO B FI N I S H TETON PRESTRESS CONCRETE MARK:(1) REQ'D DECK: ENDS: (2) LAYERS OF 6x6-W6.0xW6.0 CO1 CO2 RL1 RL2 #6 x 8'-9"1 2 3 3 2 #4 x 8'-9"4 #6 R1 9 #6 R2 9 #3 R3 18 #4 x 2'-0" #4 x 13'-0" 2 2 CO3 2 EP2 2 WP14 10/15/2021 DR. SHINE CARWASH STEEL TROWEL FORM NORMAL 4000 PSI 6000 PSI 79.0 FT3 11,850 LBS (8) 1/2"∅ 270 K # # # # 19'-01 2" 7' - 0 1 2" 19'-01 2" 8" FACE VIEW SIDE VIEW BOTTOM VIEW 1'-8"7'-87 8"9'-75 8" 3' - 3 1 2" 19'-01 2" 8" 5/ CO 5/ 5/ CO FA5 SIDE 2" CO 2 16'-51 4 "81 4 "LIFTING CO2 / CO3 CO 11 1 2" CO 4 5' - 1 1 2" 11 1 2" CO CO 1'-11"  [   DOWE/ 1' - 3 " LI F T I N G 1' - 3 " 5/ 4' - 6 1 2" 7'-6"7'-31 2"4'-3" 5/ 4'-3" EP2 8" 3" 21 2" 1 2"Ø STRAND21 2" 1' - 4 " 334" 3' - 9 " CO 1' - 4 " 334 "   [   DOWE/S   [   DOWE/S   5  [   1' - 0 " 2' - 6 1 2" 2' - 6 " 1' - 0 " 1'-81 4" 1'-73 4 " 1'-71 4" E3 FO//OW 5OOF S/O3E 4'-101 2"9'-11" CO N C R E T E CO L O R : G R E Y TYPE: RELEASE: 28 DAY: VOLUME: WEIGHT: ST R A N D LO W L A X ME S H CA S T I N M A T E R I A L RE B A R PL A I N A S T M A 6 1 5 - 6 0 DA T E JO B FI N I S H TETON PRESTRESS CONCRETE MARK:(1) REQ'D DECK: ENDS: (2) LAYERS OF 6x6-W6.0xW6.0 CO4 CO2 RL1 RL2 #6 x 6'-10"1 2 4 4 2 #4 x 6'-10"2 #4 R6 2 EP2 3 WP16 9/4/2021 DR. SHINE CARWASH STEEL TROWEL FORM NORMAL 4000 PSI 6000 PSI 72.4 FT3 10,850 LBS (8) 1/2"∅ 270 K # # # # 3" 21 2" #6 BAR21 2" 9" CO2 RL2 RL1 CO1 CO1 RL2 9'-13 4" 1' - 4 " 9'-13 4" 8" 8" F$CE 9IEW SIDE 9IEW %OTTO0 9IEW 1'-81 2"1'-81 2"5'-83 4" 4" 4" 4" 8" 8" RL1 LIFTING LI F T I N G CO 1 4" 2" 2" 4" 8" 4" 4" CO3 CO3S 61 2" CO N C R E T E CO L O R : G R E Y TYPE: RELEASE: 28 DAY: VOLUME: WEIGHT: ST R A N D LO W L A X ME S H CA S T I N M A T E R I A L RE B A R PL A I N A S T M A 6 1 5 - 6 0 DA T E JO B FI N I S H TETON PRESTRESS CONCRETE MARK:(1) REQ'D DECK: ENDS: (2) LAYERS OF 6x6-W6.0xW6.0 CO1 CO2 RL1 RL2 1 4 2 1 #6 x 8'-11"4 CO3 2 CO3S 2 WP22 10/20/2021 DR. SHINE CARWASH STEEL TROWEL FORM NORMAL 4000 PSI 6000 PSI 8.2 FT3 1,230 LBS # # # # # PR O F ES S I O N A L ENGI N E E R S TATE O F I D A HO A 9/ 7 / 2 3 14 1 3 4 D VID B . P O R T ER L I C E N SED GENERAL STRUCTURAL NOTES (APPLY UNLESS NOTED OTHERWISE ON PLANS/DETAILS) GENERAL REQUIREMENTS: 1.THE STRUCTURAL SYSTEMS AND MEMBERS DEPICTED HEREIN HAVE BEEN DESIGNED PRIMARILY TO SAFEGUARD AGAINST MAJOR STRUCTURAL DAMAGE AND LOSS OF LIFE, NOT TO LIMIT DAMAGE OR MAINTAIN FUNCTION (IBC SECTION 101.3). 2.THESE DRAWINGS, AND THEIR ASSOCIATED STRUCTURAL CALCULATIONS, HAVE BEEN PERFORMED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE STRUCTURAL ENGINEER'S IN THIS OR SIMILAR LOCALITIES. THEY NECESSARILY ASSUME THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKMEN WHO HAVE A WORKING KNOWLEDGE OF THE INTERNATIONAL BUILDING CODE CONVENTIONAL FRAMING REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR FRAMING ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, IT IS UNDERSTOOD THAT THE CONTRACTOR WILL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR ALL MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3.THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION SUCH THAT DESIGN LIVE LOAD PER SQUARE FOOT AS STATED HEREIN IS NOT EXCEEDED. OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF AN OPTION IS USED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES, AND SHALL COORDINATE ALL DETAILS. 4.WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. TYPICAL DETAILS AND NOTES ARE NOT NECESSARILY INDICATED ON THE PLANS, BUT SHALL APPLY NONE-THE-LESS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. DETAILS MAY SHOW ONLY ONE SIDE OF CONNECTION OR MAY OMIT INFORMATION FOR CLARITY. 5.ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ARCHITECT AND STRUCTURAL ENGINEER. 6.ANY INSPECTIONS, SPECIAL (IBC CHAPTER 17) OR OTHERWISE THAT ARE REQUIRED BY THE BUILDING CODES, LOCAL BUILDING DEPARTMENTS, OR BY THESE PLANS SHALL BE DONE BY AN INDEPENDENT INSPECTION COMPANY OR THE BUILDING DEPARTMENT, SITE VISITS BY THE STRUCTURAL ENGINEER DO NOT CONSTITUTE AN OFFICIAL INSPECTION, UNLESS SPECIFICALLY CONTRACTED FOR. 7.SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS IN ADDITION TO ITEMS REQUIRED BY ARCHITECTURAL SPECIFICATIONS, THE CONTRACTOR SHALL REVIEW ALL SHOP DRAWINGS PRIOR TO SUBMITTAL. ITEMS NOT IN ACCORDANCE WITH CONTRACT DRAWINGS SHALL BE FLAGGED UPON HIS REVIEW. VERIFY ALL DIMENSIONS WITH ARCHITECT. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM ORIGINAL CONTRACT DRAWINGS SHALL BE CLOUDED. ANY OF THE AFOREMENTIONED WHICH ARE NOT CLOUDED OR FLAGGED BY SUBMITTING PARTIES, SHALL NOT BE CONSIDERED APPROVED AFTER THE STRUCTURAL ENGINEER'S REVIEW, UNLESS NOTED ACCORDINGLY. ANY ENGINEERING PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW, SHALL BEAR THE SEAL OF A STRUCTURAL ENGINEER REGISTERED IN THE APPROPRIATE STATE. THE SHOP DRAWINGS DO NOT REPLACE THE ORIGINAL CONTRACT DRAWINGS. ITEMS OMITTED OR SHOWN INCORRECTLY AND ARE NOT FLAGGED BY THE STRUCTURAL ENGINEER ARE NOT TO BE CONSIDERED CHANGES TO ORIGINAL DRAWINGS. THE ADEQUACY OF ENGINEERING DESIGNS AND LAYOUT PERFORMED BY THE OTHERS RESTS WITH THE DESIGNING OR SUBMITTING AUTHORITY. REVIEWING IS INTENDED ONLY AS AN AID TO THE CONTRACTOR IN OBTAINING CORRECT SHOP DRAWINGS. RESPONSIBILITY FOR CORRECTNESS SHALL REST WITH THE CONTRACTOR. ALLOW (5) WORKING DAYS FOR THE STRUCTURAL ENGINEER'S REVIEW. ONE COPY OF EACH SUBMITTAL WILL BE RETAINED FOR THE STRUCTURAL ENGINEER'S RECORDS. BASIS FOR DESIGN: 1.BUILDING CODE: 2018 EDITION OF THE IBC WITH CITY/COUNTY AMENDMENTS. RISK CATEGORY = II 4. SEISMIC DESIGN PARAMETERS: ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE IMPORTANCE FACTOR Ie = 1.00 SITE CLASS D SEISMIC DESIGN CATEGORY D MAPPED SPECTRAL RESPONSE ACCELERATIONS S1 = 0.141, SS = 0.373 DESIGN SPECTRAL RESPONSE ACCELERATIONS SD1 = 0.218, SDS = 0.374 PERCENT SNOW INCLUDED WITH SEISMIC LOADS 20% VERTICAL SHEAR TRANSFER ELEMENTS: INTERMEDIATE PRECAST SHEARWALL(S)R = 4.0, CS = 0.094 5. WIND DESIGN PARAMETERS (STRENGTH): ULTIMATE WIND SPEED 115 MPH (3 SECOND GUST) WIND EXPOSURE C IMPORTANCE FACTOR Iw = 1.00 INTERNAL PRESSURE COEFFICIENT -0.18 COMPONENT AND CLADDING PRESSURE 27.8 PSF NET UPLIFT ON ROOF 4.5 PSF 2. VERTICAL LOADS: LOCATION LIVE / SNOW LOAD DEAD LOAD PRECAST ROOF 35 PSF 50 PSF 3. DEFLECTION LIMITS: ELEMENTS LIVE LOAD TOTAL LOAD ROOF PANELS L/360 L/240 BEAMS L/360 L/240 FOUNDATION NOTES: 1.FOUNDATIONS DESIGNED IN CONFORMANCE WITH RECOMMENDATIONS BY: ATLAS, INC. REPORT NO. E212744g, DATED DECEMBER 1, 2021. 2.SITE PREPARATION AND GRADING REQUIREMENTS OF THE SOIL REPORT AND ANY ADDENDUM'S SHALL BE COMPLETED PRIOR TO CONSTRUCTION OF FOUNDATIONS. ANY TESTS OR INSPECTIONS REQUIRED BY THE SOIL REPORT SHALL BE PERFORMED PRIOR TO PLACEMENT OF FOUNDATION REINFORCING STEEL OR CONCRETE. ALTERATIONS TO SITE PREPARATION OR GRADING SHALL BE REPORTED TO THE GEOTECHNICAL ENGINEER PRIOR TO FOUNDATION CONSTRUCTION. 3.A ONE-THIRD INCREASE IN BEARING PRESSURES IS ALLOWED WITH SEISMIC OR WIND LOAD COMBINATIONS. LATERAL BEARING AND LATERAL SLIDING RESISTANCE MAY BE COMBINED. 4.ALL FOUNDATIONS SHALL BEAR ON COMPACTED ENGINEERED FILL OR COMPETENT NATIVE SOIL SUBBASE COMPACTED TO 95% DRY DENSITY (STANDARD PROCTOR). GRADE IS DEFINED AS LOWEST ADJACENT GRADE WITHIN 5 FEET OF THE BUILDING FOR PERIMETER FOOTINGS. WHERE EXTERIOR PAVING OR CONCRETE IS DIRECTLY ADJACENT TO BUILDING, GRADE IS DEFINED AS TOP OF EXTERIOR PAVING AT LEAST 5 FEET FROM BUILDING. CONCRETE FOOTING EXCAVATIONS SHALL BE CLEAN AND FREE OF LOOSE DEBRIS OR UN-COMPACTED MATERIAL AT TIME OF CONCRETE PLACEMENT. 5.CONCRETE SLABS ON GRADE SHALL BE SUPPORTED ON A 4 INCH (MIN) LAYER OF FREE-DRAINING GRANULAR MAT (DRAINAGE FILL COURSE). THE MAT SHOULD CONSIST OF A WELL GRADED SAND AND GRAVEL MIXTURE WITH MAXIMUM 3/4-INCH CRUSHED AGGREGATE. THE GRANULAR MAT SHOULD BE COMPACTED TO NO LESS THAN 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D1557 6.BACKFILL AGAINST RESTRAINED WALLS SHALL NOT BE PLACED UNTIL AFTER THE WALLS ARE SUPPORTED BY THE COMPLETION OF INTERIOR FLOOR SYSTEMS AND CONCRETE OR GROUT STRENGTH HAS REACHED THE 28 DAY STRENGTH LISTED BELOW. THE SOIL DESIGN VALUES FOR THE FOUNDATION ARE: ALLOWABLE BEARING PRESSURE 2500 PSF ALLOWABLE LATERAL BEARING PRESSURE 346 PSF/FT ALLOWABLE LATERAL SLIDING COEFFICIENT .35 FOUNDATION BEARING DEPTH 36" BELOW FINISHED GRADE CONCRETE: 2.ALL NORMAL WEIGHT CONCRETE SHALL BE REGULAR WEIGHT OF 150 POUNDS PER CUBIC FOOT USING HARD-ROCK AGGREGATES. AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. 3.LAP SPLICES FOR BEAMS AND FLOOR SLABS SLABS SHALL BE ACCORDING TO CHAPTER 12 OF ACI 318 OR LAP SCHEDULE ON THESE DRAWINGS. STAGGER SPLICES A MINIMUM OF ONE LAP LENGTH. NO TACK WELDING OF REINFORCING BARS ALLOWED WITHOUT PRIOR REVIEW OF PROCEDURE WITH THE STRUCTURAL ENGINEER. LATEST ACI CODE AND DETAILING MANUAL APPLY. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. VERTICAL WALL BARS SHALL BE SPLICED AT OR NEAR FLOOR LINES. 4.ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING STEEL NOT NOTED AS "CLEAR" OR "CLR" ARE TO CENTER OF STEEL. MINIMUM COVER FOR NON-PRESTRESSED CONCRETE REINFORCING SHALL BE AS FOLLOWS: 5.MAXIMUM SLUMP FOR ALL CONCRETE SHALL BE 6". PORTLAND CEMENT SHALL CONFORM TO ASTM C150. TYPE V CEMENT SHALL BE USED FOR CONCRETE IN CONTACT WITH ALKALINE SOIL, AND TYPE II ELSEWHERE. 6.NO MORE THAN 90 MINUTES SHALL ELAPSE BETWEEN CONCRETE BATCHING AND CONCRETE PLACEMENT UNLESS APPROVED BY THE TESTING AGENCY. 7.CONCRETE PLACEMENT AND QUALITY SHALL BE PER RECOMMENDATIONS IN ACI 614, ACI 301 AND ACI 318. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS ON GRADE NEED BE VIBRATED ONLY AROUND AND UNDER FLOOR DUCTS, ETC. CAST CLOSURE POUR, WHERE SHOWN ON PLANS AROUND COLUMNS AFTER COLUMN DEAD LOAD IS APPLIED. REMOVE ALL DEBRIS FROM FORMS BEFORE PLACING CONCRETE. ALL ITEMS TO BE CAST IN CONCRETE SUCH AS REINFORCING, DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY POSITIONED IN THE FORMS BEFORE PLACING THE CONCRETE. 8.ALL CONCRETE SLABS ON GRADE SHALL BE DIVIDED INTO AREAS BY CONTROL JOINTS (KEYED OR SAW CUT) SUCH THAT ONE SLAB AREA DOES NOT EXCEED A MAXIMUM LENGTH OF 24 TIMES THE SLAB THICKNESS IN BOTH DIRECTIONS (EXAMPLE: 4" SLAB = 8'-0" LENGTH). SQUARE LAYOUTS ARE PREFERRED, BUT THE SLAB GEOMETRY MAY DICTATE OTHERWISE. THE RATIO OF THE LONG TO SHORT DISTANCE SHALL NOT EXCEED 1.3. IT IS RECOMMENDED THAT SAW CUTS BE MADE WITHIN 16 HOURS OF CONCRETE BATCHING. KEYED CONTROL JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING POURING, ALL OTHER JOINTS MAY BE SAW CUT. 9.HORIZONTAL PIPES AND ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE AND SLABS ON GRADE EXCEPT WHERE SPECIFICALLY APPROVED OR NOTED BY THE STRUCTURAL ENGINEER. PIPES AND CONDUITS SHALL NOT IMPAIR THE STRENGTH OF THE WORK. 10.FLY ASH MAY BE USED ONLY IF PERMITTED BY ARCHITECTURAL SPECIFICATIONS AND SHALL BE LIMITED TO 18 PERCENT OF CEMENTITIOUS MATERIALS AND SHALL HAVE A REPLACEMENT FACTOR OF 1.2 RELATIVE TO CEMENT REPLACED. NO FLY ASH ADDITIVES SHALL BE USED IN FLATWORK OR ARCHITECTURAL EXPOSED CONCRETE. 11.COLD/HOT WEATHER CONCRETE CONSTRUCTION: PROTECT CONCRETE FROM DAMAGE OR REDUCED STRENGTH IN COMPLIANCE WITH ACI 305 AND 306. 12.CONCRETE MIXES SHALL BE DESIGNED BY A CERTIFIED LABORATORY AND APPROVED BY THE STRUCTURAL ENGINEER. 13.LIMIT ALKALI-SILICA REACTION (ASR) TO 0.1% EXPANSION AT 28 DAYS IN CONCRETE MIX AT ALL EXTERIOR CONCRETE AND INTERIOR CONCRETE EXPOSED TO MOISTURE. LOCATION:MINIMUM COVER TOLERANCE CAST AGAINST EARTH (FOOTINGS)3" ± 3 8" SLABS ON GRADE 1 12" ± 14" EXPOSED TO EARTH OR WEATHER - #5 AND SMALLER 1 12" ± 3 8" EXPOSED TO EARTH OR WEATHER - #6 AND LARGER 2"± 3 8" NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND ROOF SLAB 1"18" STRUCTURAL SLABS AND WALLS 3 4"18" BEAMS AND COLUMNS (PRIMARY) REINFORCEMENT, TIES, STIRRUPS AND SPIRALS 112"3 8" 1. MINIMUM 28 DAY CONCRETE STRENGTH SHALL BE AS FOLLOWS: USE:CONCRETE STRENGTH: MAX W/C RATIO AIR ENTRAINMENT FOUNDATIONS 3500 PSI 0.45 5.5% ± 1% CONCRETE SLABS ON GRADE & TOPPING SLAB 3500 PSI 0.45 N/A PRECAST WALLS & ROOF HOLLOW CORE PANELS 6000 PSI 0.36 2.0% ± 1.5% REINFORCING STEEL: 1.ASTM A615 GRADE 60 (FY = 60 KSI) DEFORMED BARS FOR ALL BARS #4 AND LARGER. ASTM A615 GRADE 40 (FY = 40 KSI) DEFORMED BARS FOR ALL BARS #3 AND SMALLER. GRADE 60 DEFORMED BARS SHALL BE USED FOR CONCRETE WALLS, BEAMS, ELEVATED SLABS AND COLUMN REINFORCING. 2.WELDING OF REINFORCING BARS SHALL BE MADE ONLY TO ASTM A706 GRADE 60 BARS AND ONLY USING E90 SERIES RODS. WELDING OF REINFORCING BARS SHALL BE MADE ONLY AT LOCATIONS SHOWN ON PLANS OR DETAILS. 3.REINFORCING BAR SPACING GIVEN ARE MAXIMUM ON CENTERS. ALL BARS PER CRSI SPECIFICATIONS AND HANDBOOK. DOWEL ALL VERTICAL REINFORCING TO FOUNDATION. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. DEFERRED SUBMITTAL ITEMS: PRECAST WALLS AND HOLLOW CORE ROOF PANELS SHEET INDEX SHEET DESCRIPTION DETAILS S1.0 GENERAL STRUCTURAL NOTES --- S1.1 TYPICAL DETAILS T-SERIES S2.0 FOUNDATION PLAN --- S2.1 ROOF FRAMING PLAN --- S3.0 FOUNDATION DETAILS 100 - SERIES S4.0 ROOF FRAMING DETAILS 200 - SERIES S5.0 PANEL WALL ELEVATIONS --- CAST IN PLACE CENTERLINE CENTERLINE OF BEAM CENTERLINE OF COLUMN CENTERLINE OF WALL CLEAR CONCRETE CONCRETE CONTROL JOINT CONCRETE SAWCUT JOINT CONCRETE MASONRY UNIT CONNECTION CONTINUOUS DEAD LOAD DOWN DRAWING(S) EQUAL EQUIPMENT EXPANSION JOINT EACH WAY FINISHED FLOOR FACE OF STEEL FACE OF WALL GAUGE GALVANIZED GENERAL STRUCTURAL NOTES CENTERLINE OF FOOTING FACE OF MEMBER EXPANSION BOLT EDGE OF SLAB DIAMETER GALV GSN DN. DWG(S) EQ EQUIP EXP. JT (E.J.) E.W. F.F. F.O.S. F.O.W. GA F.O.M. EXP. BOLT E.O.S. Ø OR DIA. C.I.P. C L C.L.B. C.L.C. C.L.W. CLR CONC C.C.J. C.S.J. C.M.U. CONN. CONT D L C.L.F. W/ WITH W/O WITHOUT T.O.P. U.N.O. W.W.F. TYP VERT T.O.S. T.O.W. T.O.D. T.O.F. T.O.L. T.O.M. STD T.O.B. T L SLH SLV SIM SQ PSF PSI REINF PREFAB OPP P.C. PLF N.T.S. O.C. O.F.W. TOP OF FOOTING UNLESS NOTED OTHERWISE WELDED WIRE FABRIC TOP OF MASONRY TOP OF PLATE TOP OF STEEL TOP OF WALL TYPICAL VERTICAL STANDARD TOP OF BEAM TOP OF DECK TOP OF LEDGER TOTAL LOAD OUTSIDE FACE OF WALL PRECAST CONCRETE POUNDS PER LINEAR FOOT POUNDS PER SQUARE INCH SHORT LEG VERTICAL SHORT LEG HORIZONTAL REINFORCING SIMILAR SQUARE NOT TO SCALE ON CENTER OPPOSITE PREFABRICATED AGGREGATE BASE COURSE AIR CONDITIONER ABOVE FINISHED FLOOR ALTERNATE ANCHOR BOLT AT (MEASUREMENT) BEAM BOTTOM OF BEAM BOTTOM OF DECK BEARING BELOW FINISHED FLOOR BOTTOM OF FOOTING A.B.C. A/C A.F.F. ALT A.B. @ BM B.O.B. B.O.D. BRG B.F.F B.O.F. ABBREVIATIONS LBS (#) MFR('S) M.C.J. MECH N/A LLV LLH HORIZ K(KIP) L L LONG LEG VERTICAL MANUFACTURER('S) MASONRY CONTROL JOINT NOT APPLICABLE LONG LEG HORIZONTAL POUNDS MECHANICAL HORIZONTAL 1000 POUNDS LIVE LOAD EXISTING(E) MIN MINIMUM MAX MAXIMUM POUNDS PER SQUARE FOOT GLUED-LAMINATED BEAMGLB PFT PREFAB FLOOR TRUSSES PRT PREFAB ROOF TRUSSES I.F.W.INSIDE FACE OF WALL PT PRESSURE TREATED CONCRETE COLUMNC.C. ANCHORAGE TO CONCRETE: ADHESIVE ANCHORS: HILTI HIT-HY 200 PER ICC ESR-3187 HILTI HIT-RE 500 V3 PER ICC ESR-3814 SIMPSON SET-3G PER ICC ESR-4057 MECHANICAL ANCHORS: HILTI KWIK HUS PER ICC ESR-3027 HILTI KWIK BOLT-TZ EXPANSION ANCHORS PER ICC ESR-1917 SIMPSON TITEN HD PER ICC ESR-2713 SIMPSON STRONG BOLT-2 PER ICC ESR-3037 REBAR DOWELING TO CONCRETE: ADHESIVES: HILTI HIT-HY 200 PER ICC ESR-3187 HILTI HIT-RE 500 V3 PER ICC ESR-3814 SIMPSON AT-XP PER IAPMO ER-263 SIMPSON SET-XP PER ICC ESR-2508 2.SUBSTITUTION REQUESTS FOR ALTERNATE PRODUCTS MUST BE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER OF RECORD PRIOR TO USE. CONTRACTOR SHALL PROVIDE CALCULATIONS DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE PERFORMANCE VALUES OF THE SPECIFIED PRODUCT. SUBSTITUTIONS WILL BE EVALUATED BY THEIR HAVING AN ICC ESR OR IAPMO ER SHOWING COMPLIANCE WITH THE RELEVANT BUILDING CODE FOR SEISMIC USES, LOAD RESISTANCE, INSTALLATION CATEGORY, AND AVAILABILITY OF COMPREHENSIVE INSTALLATION INSTRUCTIONS. ADHESIVE ANCHOR EVALUATION WILL ALSO CONSIDER CREEP, IN-SERVICE TEMPERATURE AND INSTALLATION TEMPERATURE. 3.INSTALL THE ANCHORS PER THE MANUFACTURER INSTRUCTIONS, AS INCLUDED IN THE ANCHOR PACKAGING. 4.THE CONTRACTOR SHALL ARRANGE AN ANCHOR MANUFACTURER'S REPRESENTATIVE TO PROVIDE ONSITE INSTALLATION TRAINING FOR ALL OF THEIR ANCHORING PRODUCTS SPECIFIED. THE STRUCTURAL ENGINEER OF RECORD MUST RECEIVE DOCUMENTED CONFIRMATION THAT ALL OF THE CONTRACTOR'S PERSONNEL WHO INSTALL ANCHORS ARE TRAINED PRIOR TO THE COMMENCEMENT OF INSTALLING ANCHORS. 5.ANCHOR CAPACITY IS DEPENDANT UPON SPACING BETWEEN ADJACENT ANCHORS AND PROXIMITY OF ANCHORS TO EDGE OF CONCRETE. INSTALL ANCHORS IN ACCORDANCE WITH SPACING AND EDGE CLEARANCES INDICATED ON THE DRAWINGS. POST-INSTALLED ANCHORS: 1.EXCEPT WHERE INDICATED ON THE DRAWINGS, POST-INSTALLED ANCHORS SHALL CONSIST OF THE FOLLOWING ANCHOR TYPES. ALL ANCHORS ARE TO BE INSTALLED PER THE MANUFACTURERS RECOMMENDATIONS. SPECIAL INSPECTION ITEMS: 1.THE OWNER OR THE OWNER'S AUTHORIZED AGENT, OTHER THAN THE CONTRACTOR, SHALL EMPLOY ONE OR MORE APPROVED AGENCIES TO PROVIDE SPECIAL INSPECTIONS AND TESTS DURING CONSTRUCTION ON THE TYPES OF WORK SPECIFIED PER IBC SECTION 1705 AND IDENTIFY THE APPROVED AGENCIES TO THE BUILDING OFFICIAL. SPECIAL INSPECTIONS ARE REQUIRED AS FOLLOWS: 2.QUALITY ASSURANCE PROGRAM: A.THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED TO BE CERTAIN IT CONFORMS WITH THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS. B.THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL, AND TO THE STRUCTURAL ENGINEER OF RECORD. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED, TO THE DESIGN AUTHORITY AND THE BUILDING OFFICIAL. CONCRETE (IBC TABLE 1705.3) VERIFICATION AND INSPECTION CONTINUOUS SPECIAL INSPECTION PERIODIC SPECIAL INSPECTION 1. INSPECT REINFORCEMENT, INCLUDING PRESTRESSING TENDONS, AND VERIFY PLACEMENT - X 2. REINFORCING BAR WELDING: A. VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN ASTM A 706;-X B. INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM 5 16" ; AND X C. INSPECT ALL OTHER WELDS.X 3. INSPECT ANCHORS CAST IN CONCRETE - X 4. INSPECT ANCHORS POST INSTALLED IN HARDENED CONCRETE MEMBERS. A. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY INCLINED ORIENTATIONS TO RESIST SUSTAINED TENSION LOADS. X B. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN 4.A. X 5. VERIFY USE OF REQUIRED DESIGN MIX.- X 6. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE CONCRETE. X - 7. INSPECT CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES.X - 8. VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES.- X 9. INSPECT ERECTION OF PRECAST CONCRETE MEMBERS.- X 10. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED.- X ANCHORAGE TO CONCRETE: ADHESIVE ANCHORS: HILTI HIT-HY 200 PER ICC ESR-3187 HILTI HIT-RE 500 V3 PER ICC ESR-3814 SIMPSON AT-XP PER IAPMO ER-263 SIMPSON SET-XP PER ICC ESR-2508 MECHANICAL ANCHORS: HILTI KWIK HUS PER ICC ESR-3027 HILTI KWIK BOLT-TZ EXPANSION ANCHORS PER ICC ESR-1917 SIMPSON TITEN HD PER ICC ESR-2713 SIMPSON STRONG BOLT-2 PER ICC ESR-3037 ADHESIVES: HILTI HIT-HY 200 PER ICC ESR-3187 HILTI HIT-RE 500 V3 PER ICC ESR-3814 SIMPSON AT-XP PER IAPMO ER-263 SIMPSON SET-XP PER ICC ESR-2508 REBAR DOWELING TO CONCRETE: SOILS (IBC TABLE 1705.6) VERIFICATION AND INSPECTION CONTINUOUS SPECIAL INSPECTION PERIODIC SPECIAL INSPECTION 1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY.- X 2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. - X 3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS. - X 4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESS DURING PLACEMENT AND COMPACTION OF COMPACTED FILL. X - 5. PRIOR TO PLACEMENT OF COMPACTED FILL, INSPECT SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY. - X 40 1 E A S T 1 7 0 0 S O U T H , S A L T L A K E C I T Y , U T A H ( 8 0 1 ) 4 8 4 - 2 0 4 6 AR C H I T E C T S A N D P L A N N E R S VI N C E N T D E S I G N G R O U P , I N C . T A G G N G O C A R W A S H S1.0 PROJECT MANAGER: CAD OPERATOR:JOB NO.: fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 Structural Engineering phone: 208.227.8404 This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. contact@frost-structural.com AVJHIF23-388 KEYNOTES: 1.FINISHED GRADE WHERE OCCURS 2. DO NOT EXCAVATE A TRENCH CLOSER THAN A 45 DEGREE ANGLE TO BELOW BOTTOM FOOTING OR FOUNDATION 3.BOTTOM OF CONCRETE FOOTING 4.BOTTOM OF TRENCH NOTE: A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPE OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS 1 1 1 2 3 4 FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T1 TRENCH PARALLEL TO CONTINUOUS STRAP FOOTING TD01 NO SCALE KEYNOTES: 1.CONCRETE FOOTING 2.SLEEVE - PROVIDE 12" MINIMUM CLEARANCE AROUND PIPE OR CONDUIT 3.PIPE OR CONDUIT 4.CONCRETE FILL TO BE PLACED BEFORE FOOTING IS POURED - FORM SAME AS FOOTING AND POUR FULL WIDTH OF PIPE TRENCH 5.STEM WALL NOTE: A.NO PIPE SHALL PASS THRU FOOTING OR UNDER COLUMN FOOTINGS. FOR TRENCHES GREATER THAN 3'-6" BELOW BOTTOM OF FOOTING, SEE PIPE PASSING BELOW WALL FOOTING DETAIL. 1 2 3 4 5 5 4 2 1 3 T2 PIPE PASSING UNDER WALL FOOTING IN SHALLOW TRENCH TD02 NO SCALE 6" M I N 8" M I N 3' - 0 " M A X 8" MIN A SECTIONA KEYNOTES: 1.STEM WALL 2.CONCRETE FOOTING 3.1'-6" MAXIMUM - WHERE TRENCH EXCEEDS 1'-6" NOTIFY STRUCTURAL ENGINEER PRIOR TO PLACEMENT OF FOOTINGS 4.BACKFILL AND RECOMPACT TRENCH PER SOILS REPORT AND SPECIFICATIONS 5.BOTTOM OF TRENCH NOTE: A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPES OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS 1 5 4 3 2 3' - 1 " O R G R E A T E R FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T3 PIPE PASSING BELOW FOOTING IN DEEP TRENCH TD03 NO SCALE KEYNOTES: 1.SLOPED FINISH GRADE 2. MINIMUM FOOTING DEPTH PER G.S.N. - 12" MINIMUM 3.DEEPEN FOOTING AS REQUIRED TO ACCOUNT FOR SLOPED GRADE 4.CONCRETE FOOTING NOTE: A.FOR ADDITIONAL INFORMATION, SEE PLANS AND DETAILS 1 4 3 2 5'-0" T4 TYPICAL DETAIL FOR FOUNDATION EMBEDMENT TD04 NO SCALE KEYNOTES: 1.CORNER DOWELS TO MATCH HORIZONTAL REINFORCEMENT 2.CONCRETE WALL WITH REINFORCEMENT 18" MIN LAP SPLICE (TYP) T5 TYPICAL CONCRETE CORNER TD05 NO SCALE 2 1 KEYNOTES: 1.CONCRETE SLAB ON GRADE 2.CONT KEYED JOINT 3.SAWCUT 18" WIDE x 14 SLAB THICKNESS IN DEPTH - CUT SHALL BE MADE SOON ENOUGH TO PREVENT SHRINKAGE CRACKING, BUT NOT SO SOON AS TO CAUSE SPALLING OF THE CONCRETE WHILE SAWING. WORK MUST BE COMPLETE WITHIN 16 HOURS OF CONCRETE PLACEMENT. NOTE: A.KEYED JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING PLACEMENT UNLESS SPECIFICALLY NOTED ON THE PLANS. B."TOOL WET JOINT", "ZIP STRIP", ETC SHALL MATCH SAWCUT REQUIREMENTS 1 2 3 1 12"6"6"12" X SAWCUT JOINT X KEYED JOINT T6 CONTROL JOINTS IN CONCRETE SLAB ON GRADE TD07 NO SCALE 6 MIN BAR OFFSET BAR CLEARANCE SPLICE DETAIL BEND & HOOK DETAILS COLUMN TIES BEAM STIRRUPS "d" 45° "d" "d" 1 2 4 5 6 10 9 8 7 3 1 5 5 9 10 8 KEYNOTES: 1.LAP - SEE G.S.N. 2.MAXIMUM 15 LAP BUT NOT MORE THAN 6" 3. WIRE TIES 4.1d (1" MINIMUM) 5.RADIUS = 3d FOR BARS NOT OVER #8; 4d FOR #9, #10, AND #1 BARS; 5d FOR #14 AND #18 BARS, 5d FOR ALL GRADE 40 BARS WITH 180 DEGREE HOOK 6.4D (4" MINIMUM) 7.12d (90 DEGREE HOOK) 8.6d (4" MINIMUM) 9.135 DEGREE BEND 10.BEND AROUND 112" PIN FOR #3 BARS. BEND AROUND 2" PIN FOR #4 BARS. BEND AROUND 212" PIN FOR #5 BARS. T7 TYPICAL REINFORCING DETAILS TD10 NO SCALE NOTES: 1. TOP BARS ARE ANY HORIZONTAL BARS PLACED SO THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT. 2. UNLESS NOTED OTHERWISE, LAP SPLICES IN CONCRETE BEAMS, SLABS AND WALLS SHALL BE CLASS "B" TENSION LAP SPLICES. BAR SIZE CLASS B TENSION SPLICE LENGTHS f'c = 3,000 PSI f'c = 4,000 PSI f'c = 5,000 PSI HOIRZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HOIRZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HOIRZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS #3 12" 12" 12" 12" 12" 12" #4 19" 15"17"13" 15"12" #5 29" 23" 26" 20" 23" 18" #6 32" 25" 28"21"25" 19" #7 54"41" 47"36"42"32" #8 70"54"61" 47"54"42" #9 89" 68"77"59" 69" 53" #10 112"87" 97"75"87" 67" T9 STEEL REINFORCING LAP SPLICES IN CONCRETE TD14 NO SCALE T8 TYPICAL PIPE THROUGH STEM WALL TD61 NO SCALE NOTE: A.NO PIPE SHALL PASS THROUGH FOOTINGS OR UNDER COLUMN FOOTINGS. FOR ADDITIONAL INFORMATION SEE PLANS AND DETAILS B.MULTIPLE PIPES/CONDUIT SLEEVES ALLOWED PROVIDED SLEEVES ARE SPACED W/ MINIMUM OF 2x SLEEVE DIAMETER BETWEEN SLEEVES C. SLEEVES SHALL NOT OCCUR WITHIN 12" OF POINT LOADS OR HOLDOWN ANCHORS 1' - 0 " MI N 1 7 3 4 5 6 KEYNOTES: 1.WALL AS OCCURS, SEE PLAN 2.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3.SLEEVE, 8"Ø MAX, PROVIDE 12" MINIMUM CLEARANCE AROUND PIPE-CONDUIT 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.PIPE OR CONDUIT 8.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 9.PROVIDE DRAINAGE SYSTEM BEHIND WALL, SEE TYPICAL DETAIL 10.FILTER FABRIC WRAPPED AROUND MIN 12"x12" OF GRAVEL BACKFILL 22 KEYNOTES: 1.CONCRETE WALL, SEE PLAN 2.3 1 2" STEEL STUD (33 MILS MIN THICKNESS) PLANT WALL PER ARCH, ATTACH W/ .145"DIA MIN SHOT PIN AT 16" O.C. 3.3 1 2" STUD BLOCKING TOP AND BOTTOM AND AT 16" O.C. REMAINDER 4.7 16" SHEATHING, ATTACH W/ #8 SELF TAPPING SCREWS AT 12" O.C. 5.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 1" T10 TYPICAL PLANT WALL ATTACHMENT TD05 NO SCALE 3 2 4 1 3 T11 TYPICAL SPLICE IN CONTINUOUS STEEL CHORD/EDGE ANGLE TD_SF15 NO SCALE KEYNOTES: 1.STEEL CHORD/EDGE ANGLE - FOR SIZE AND LOCATION, SEE PLAN 2.8" LONG x 2"x3 8" THICK STEEL PLATES 1/2" M A X 1/4 TYP 1 1 2 2 5 NOTE: A.WATERPROOFING OF ALL EXTERIOR ELEMENTS PER ARCH PR O F ES S I O N A L ENGI N E E R S TATE O F I D A HO A 9/ 7 / 2 3 14 1 3 4 D VID B . P O R T ER L I C E N SED 40 1 E A S T 1 7 0 0 S O U T H , S A L T L A K E C I T Y , U T A H ( 8 0 1 ) 4 8 4 - 2 0 4 6 AR C H I T E C T S A N D P L A N N E R S VI N C E N T D E S I G N G R O U P , I N C . T A G G N G O C A R W A S H S1.1 PROJECT MANAGER: CAD OPERATOR:JOB NO.: fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 Structural Engineering phone: 208.227.8404 This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. contact@frost-structural.com AVJHIF23-388 1 1 2 2 3 3 4 4 5 6 AA BB CC DD 5 2 WF24 WF24 WF24 WF 2 4 WF 2 4 WF24 WF24 F36 WF 2 4 A WF 2 4 A WF24 137'-0" 24'-0"111'-0" 14'-0"8'-0"2'-0"3'-4"43'-1"6'-0"5'-2"3'-4"34'-0"10'-0"4'-0" 35 ' - 0 " 162'-0" 12'-0" 6'-81 2"2'-0" 17 ' - 0 " 23 ' - 0 " 5' - 0 1 4" 12 ' - 0 " 3' - 0 " 4' - 0 " 12 ' - 0 " 4' - 0 " 2'-5" 3'-6"3'-4"87'-3"3'-4"27'-7" 2'-0" 10 ' - 0 " 3' - 8 " 20 ' - 0 " 15 ' - 0 " 7' - 1 0 1 2" 3' - 4 " 3' - 9 1 2" 4' - 9 " 10 ' - 6 " 4' - 9 " 15 ' - 0 " 5' - 0 " 20 ' - 0 " 40 ' - 0 " 102'-8"47'-4" 3'-31 2" 4' - 0 " 4' - 0 " 20 ' - 0 " 12'-0"12'-0"93'-0" 2'-1" 1 1 1 1 1 WF 2 4 A WF 2 4 A 2 2 TYP TOF=97'-10" TYP TOF=97'-10" TYP TOF=97'-10" TYP TOF=97'-10" 25'-0"20'-0" 6" CONCRETE SLAB ON GRADE W/ #3 AT 24" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME FINISH FLOOR = VARIES CONCRETE SLAB ON GRADE 4" CONCRETE SLAB ON GRADE W/ #3 AT 24" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME FINISH FLOOR = VARIES CONCRETE SLAB ON GRADE 106 2'-5" 6' - 4 " 102 103 101 101 108 105105 108 109 104 107 102 103 106 103 103 106 103 102 102 103 102 102 103 2'-0" A B 3 3 C H SCALE: FOUNDATION PLAN ############ FOOTING SCHEDULE NOTES: 1. FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. 2. FOR MINIMUM CLEARANCE (CLR) OF REINFORCING, SEE GENERAL STRUCTURAL NOTES (GSN). MARK LENGTH WIDTH THICKN ESS FOOTING REINFORCING REMARKS F36 36" 36" 10" (4) #4 CONT TOP & BOTTOM --- WF24 CONT 24"10"(2) #4 CONT BOTTOM WF24A CONT 24"10"(3) #4 CONT TOP & BOTTOM --- STRIP FOOTING 1. PRE-FINISHED METAL PANEL AS OCCURS PER ARCH 2. TURN DOWN SLAB TO BE USED AT OPENING, SEE DETAIL 106 3. NEW CONCRETE PANELS, SEE ELEVATIONS PLAN KEYNOTESX A. VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B. ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C. THE DEPTH OF FOOTING DIMENSION INDICATED IN THE G.S.N. IS A MINIMUM. FOUNDATION CONTRACTOR SHALL COORDINATE WITH THE SOILS REPORT AND OTHER TRADES TO INSURE THAT THESE MINIMUMS ARE SUFFICIENT FOR THE WORK. SEE TYPICAL DETAILS FOR ADDITIONAL REQUIREMENTS. D. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. E. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. E. WALLS WITH SMALL DASHED LINES DESIGNATE EXISTING WALL PANELS. SEE ORIGINAL PRECAST DRAWINGS FOR ERECTION INFORMATION. F. W1, W2, ETC. - AS SHOWN ON PLAN INDICATES CONCRETE OR MASONRY WALLS. SEE WALL SCHEDULE FOR ADDITIONAL INFORMATION. G. WF18, WF24, ETC. - AS SHOWN ON PLAN INDICATES A CONTINUOUS WALL FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. H. F36, F48, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. I. VERIFY EXACT SIZE AND LOCATION OF DEPRESSED AND/OR RAISED SLABS WITH ARCHITECTURAL DRAWINGS. J. FOR SIDEWALK AND LANDING LOCATIONS, SEE ARCHITECTURAL DRAWINGS. K. VERIFY EXACT SIZE AND LOCATION OF OPENINGS IN PRECAST CONCRETE WALL PANELS WITH ARCHITECTURAL DRAWINGS. FOUNDATION PLAN NOTES NORTH PR O F ES S I O N A L ENGI N E E R STATE O F I D A HO A 9/ 7 / 2 3 14 1 3 4 D VID B . P O R T ER L I C E N SED 40 1 E A S T 1 7 0 0 S O U T H , S A L T L A K E C I T Y , U T A H ( 8 0 1 ) 4 8 4 - 2 0 4 6 AR C H I T E C T S A N D P L A N N E R S VI N C E N T D E S I G N G R O U P , I N C . T A G G N G O C A R W A S H S2.0 PROJECT MANAGER: CAD OPERATOR:JOB NO.: fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 Structural Engineering phone: 208.227.8404 This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. contact@frost-structural.com AVJHIF23-388 1 1 2 2 3 3 4 4 5 6 AA BB CC DD 5 14 . 5 K I P S ( S T R E N G T H ) 14 . 5 K I P S ( S T R E N G T H ) 17 . 0 K I P S ( S T R E N G T H ) 28.5 KIPS (STRENGTH) 19.5 KIPS (STRENGTH) 28.5 KIPS (STRENGTH) 8" PRECAST HOLLOW CORE PANELS AT 48" O.C. (UNO) 8" PRECAST HOLLOW CORE PANELS AT 48" O.C. (UNO) (10) #4 DOWELS EVENLY SPACED AT PANEL JOINT (3) #4 DOWELS EVENLY SPACED AT PANEL JOINT (2) #4 DOWELS AT 1/3 POINTS (3) #4 DOWELS EVENLY SPACED AT PANEL JOINT (4) #4 DOWELS EVENLY SPACED AT PANEL JOINT (4) #4 DOWELS EVENLY SPACED AT PANEL JOINT (3) #4 DOWELS EVENLY SPACED AT PANEL JOINT(2) #4 DOWELS AT 1/3 POINTS(4) #4 DOWELS EVENLY SPACED AT PANEL JOINT (3) #4 DOWELS EVENLY SPACED AT PANEL JOINT 1 2 2 3 3 1 8.0 KIPS (STRENGTH) 203 203 TYP 208 TYP 208 TYP 208 207 201 201 209 206 201 205205 210 203 202 202 202 C H 211 211 211 A B SCALE: ROOF FRAMING PLAN 1/8" = 1'-0" NORTH 1. ROOF PANEL LESS THAN 48" WIDE 2. FINAL PANEL LAYOUT BY PRECAST MANUFACTURER AND TO BE REVIEWED BY FROST STRUCTURAL ENGINEERING 3. PRE-FINISHED METAL PANEL PER ARCH PLAN KEYNOTESX ROOF FRAMING PLAN NOTES A. VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B. ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C. IF DOUBLE TOP PLATE IS NOTCHED, STEPPED OR BROKEN, PROVIDE A SIMPSON MSTC40 STRAP AT DISCONTINUITY. D. TYPICAL BEARING WALL FRAMING SHALL BE 8" PRECAST CONCRETE WALLS. E. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. F. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. E. WALLS WITH SMALL DASHED LINES DESIGNATE EXISTING WALL PANELS. SEE ORIGINAL PRECAST DRAWINGS FOR ERECTION INFORMATION. G. FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING CONDITION. H. FOR CLARITY, ALL ROOF OPENINGS MAY NOT BE SHOWN ON THE ROOF FRAMING PLAN. FOR EXACT SIZE, NUMBER AND LOCATION OF OPENINGS, SEE ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS. FOR FRAMING AT OPENINGS, SEE TYPICAL DETAILS. I. INDICATES HVAC EQUIPMENT ON ROOF OR IN ATTIC SPACE. SEE TYPICAL DETAILS FOR FRAMING INFORMATION. J. VERIFY EXACT SIZE AND WEIGHT OF EQUIPMENT ON ROOF WITH MECHANICAL DRAWINGS. PR O F ES S I O N A L ENGI N E E R S TATE O F I D A HO A 9/ 7 / 2 3 14 1 3 4 D VID B . P O R T ER L I C E N SED 40 1 E A S T 1 7 0 0 S O U T H , S A L T L A K E C I T Y , U T A H ( 8 0 1 ) 4 8 4 - 2 0 4 6 AR C H I T E C T S A N D P L A N N E R S VI N C E N T D E S I G N G R O U P , I N C . T A G G N G O C A R W A S H S2.1 PROJECT MANAGER: CAD OPERATOR:JOB NO.: fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 Structural Engineering phone: 208.227.8404 This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. contact@frost-structural.com AVJHIF23-388 KEYNOTES: 1.8" CONCRETE PRECAST WALL PANEL, SEE PLAN 2.CONCRETE SLAB ON GRADE, SEE PLAN 3.EMBED CHANNEL BY PRECAST 4.3 8"x3"x0'-8" PLATE EACH SIDE 5.112" SHIM AND GROUT 6.12"x12"x1'-0" EMBED PLATE W/ (4) 12"Ø x 5" LONG HEADED STUDS 7.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 8.CONCRETE FOOTING, SEE PLAN 9.MINIMUM FOOTING DEPTH, SEE GSN 10.FINISH GRADE PER ARCH 11.GROUT OVER ALL EXPOSED STEEL BELOW GRADE 101 CONCRETE PRECAST WALL AT FOUNDATION NO SCALE 102 CONCRETE PRECAST WALL AT FOUNDATION NO SCALE 3" CLR 3" CL R 7 8 1 9 10 3 4 5 6 2 KEYNOTES: 1.PRECAST WALL PANEL BEYOND, SEE PLAN 2.CONCRETE SLAB ON GRADE, SEE PLAN 3.EMBED CHANNEL BY PRECAST 4.3 8"x3"x0'-8" PLATE EACH SIDE 5.112" SHIM AND GROUT 6.12"x12"x1'-0" EMBED PLATE W/ (4) 12"Ø x 5" LONG HEADED STUDS 7.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 8.CONCRETE FOOTING, SEE PLAN 9.MINIMUM FOOTING DEPTH, SEE GSN 10.FINISH GRADE PER ARCH 11.8" CONCRETE PRECAST WALL PANEL, SEE PLAN 12.#4 x 2'-0" DRILL AND EPOXY PER GSN 13.GROUT OVER ALL EXPOSED STEEL BELOW GRADE 3" CLR 3" CL R 7 8 1 9 10 3 4 5 6 2 11 12 KEYNOTES: 1.8" CONCRETE PRECAST WALL PANEL, SEE PLAN 2.CONCRETE SLAB ON GRADE, SEE PLAN 3.EMBED CHANNEL BY PRECAST 4.3 8"x3"x0'-8" PLATE EACH SIDE 5.112" SHIM AND GROUT 6.12"x12"x1'-0" EMBED PLATE W/ (4) 12"Ø x 5" LONG HEADED STUDS 7.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 8.CONCRETE FOOTING, SEE PLAN 9.MINIMUM FOOTING DEPTH, SEE GSN 10.FINISH GRADE PER ARCH 11.NON-STRUCTURAL FURRED OUT WOOD STUD WALL 12.GROUT OVER ALL EXPOSED STEEL BELOW GRADE 103 CONCRETE PRECAST WALL AT FOUNDATION NO SCALE 3" CLR 3" CL R 7 8 1 9 10 3 4 5 6 2 11 KEYNOTES: 1.8" CONCRETE PRECAST WALL PANEL, SEE PLAN 2.CONCRETE SLAB ON GRADE, SEE PLAN 3.EMBED CHANNEL BY PRECAST 4.3 8"x3"x0'-8" PLATE EACH SIDE 5.112" SHIM AND GROUT 6.12"x12"x1'-0" EMBED PLATE W/ (4) 12"Ø x 5" LONG HEADED STUDS 7.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 8.CONCRETE FOOTING, SEE PLAN 9.GROUT OVER ALL EXPOSED STEEL BELOW GRADE 105 CONCRETE PRECAST WALL AT FOUNDATION NO SCALE 3" CLR 3" CL R 7 8 1 2 3 4 5 6 2 KEYNOTES: 1.8" CONCRETE PRECAST WALL PANEL, SEE PLAN 2.CONCRETE SLAB ON GRADE, SEE PLAN 3.EMBED CHANNEL BY PRECAST 4.3 8"x3"x0'-8" PLATE EACH SIDE 5.112" SHIM AND GROUT 6.12"x12"x1'-0" EMBED PLATE W/ (4) 12"Ø x 5" LONG HEADED STUDS 7.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 8.CONCRETE FOOTING, SEE PLAN 9.NON-STRUCTURAL FURRED OUT WOOD STUD WALL 10.GROUT OVER ALL EXPOSED STEEL BELOW GRADE 104 CONCRETE PRECAST WALL AT FOUNDATION NO SCALE 3" CLR 3" CL R 7 8 1 2 3 4 5 6 2 9 107 CONCRETE PRECAST WALL AT FOUNDATION NO SCALE KEYNOTES: 1.PRECAST WALL PANEL BEYOND, SEE PLAN 2.CONCRETE SLAB ON GRADE, SEE PLAN 3.EMBED CHANNEL BY PRECAST 4.3 8"x3"x0'-8" PLATE EACH SIDE 5.112" SHIM AND GROUT 6.12"x12"x1'-0" EMBED PLATE W/ (4) 12"Ø x 5" LONG HEADED STUDS 7.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 8.CONCRETE FOOTING, SEE PLAN 9.8" CONCRETE PRECAST WALL PANEL, SEE PLAN 10.#4 x 2'-0" DRILL AND EPOXY PER GSN 11.GROUT OVER ALL EXPOSED STEEL BELOW GRADE 3" CLR 3" CL R 7 8 1 2 3 4 5 6 2 9 10 109 TRENCH DRAIN IN CONCRETE SLAB NO SCALE KEYNOTES: 1.#4 BENT DOWEL AT 18" O.C. 2. TRENCH DRAIN, SEE ARCHITECTURAL DRAWINGS 3. CONCRETE SLAB ON GRADE, SEE PLAN 1'-3" MIN LAP 1'-6" MIN 6" MI N 3 12 TYP 1/4 TYP 1/4 TYP TYP 1/4 TYP TYP 1/4 TYP TYP 1/4 TYP TYP 1/4 TYP TYP 1/4 11 9 10 11 13 12 106 CONCRETE SLAB AT FOUNDATION CW_S104 NO SCALE 3" CLR 3" CL R 8 7 6 5 4 3 1 2 KEYNOTES: 1.WALL BEYOND, SEE PLAN 2.#4 BENT DOWEL AT 24" O.C. 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.6" SLAB TURN DOWN TO FOUNDATION, #3 REBAR 24" O.C. 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.MINIMUM FOOTING DEPTH, SEE GSN 8.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 18" 24" KEYNOTES: 1.CONCRETE SLAB ON GRADE, SEE PLAN 2.CONT L13 4x13 4x14 W/ 14"Ø x 2" HEADED STUDS AT 18" O.C. 3.L212x212x14 W/ 14"Ø x 2" HEADED STUDS AT 18" O.C. 4.#4 BENT BARS AT 18" O.C. 5.8" CAST IN PLACE CONCRETE WALL, SEE PLAN 6. #4 BARS AT 18" O.C., EACH WAY 7.WATER STOP, SEE ARCH 8.CONCRETE SLAB W/ REINFORCEMENT, SEE PLAN 9.STEEL EMBED PLATE W/ (4) 12"Ø x 3" LONG HEADED STUDS 10.#4 x 2'-0" DRILL AND EPOXY PER GSN 11.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 12.SLOPED FLOOR PER ARCH 108 TRENCH DRAIN NO SCALE 1 4 11 6" B.O. PIT VARIES 9 2 4 5 10 66 1 3 5 10 66 7 8 12 PER ARCH PER ARCH PR O F ES S I O N A L ENGI N E E R S TATE O F I D A HO A 9/ 7 / 2 3 14 1 3 4 D VID B . P O R T ER L I C E N SED 40 1 E A S T 1 7 0 0 S O U T H , S A L T L A K E C I T Y , U T A H ( 8 0 1 ) 4 8 4 - 2 0 4 6 AR C H I T E C T S A N D P L A N N E R S VI N C E N T D E S I G N G R O U P , I N C . T A G G N G O C A R W A S H S3.0 PROJECT MANAGER: CAD OPERATOR:JOB NO.: fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 Structural Engineering phone: 208.227.8404 This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. contact@frost-structural.com AVJHIF23-388 202 PRECAST ROOF PANEL AT PRECAST CONCRETE WALL NO SCALE KEYNOTES: 1.PRECAST CONCRETE WALLS, SEE PLAN 2.CONCRETE CORBEL BY PRECAST MANUFACTURER 3.CONT 12" x 3" KOROLATH BEARING PAD OR EQUAL 4.PRECAST ROOF PANEL, SEE PLAN 5.1/4"x4"x4" EMBED PLATE W/ (1) 5 8"x5" HEADED STUD AT 48" O.C. 6.CONT L4x4X1/4 ANGLE 201 PRECAST ROOF PANEL AT PRECAST CONCRETE WALL NO SCALE KEYNOTES: 1.1/4"x4"x4" EMBED PLATE W/ (1) 5 8"x5" HEADED STUD AT 48" O.C. 2.PRECAST CONCRETE WALLS, SEE PLAN 3.PRECAST ROOF PANEL, SEE PLAN 4.CONT 12" x 3" KOROLATH BEARING PAD OR EQUAL 5.CONCRETE CORBEL BY PRECAST MANUFACTURER 6.CONT L4x4X1/4 ANGLE 6" 4" MIN BEARING 4" MIN BEARING 6" 1 2 3 1 5 4 2 34 5 NOTE: A.PRECAST MANUFACTURER SHALL DESIGN PARAPET FOR ±38 PSF (ASD) WIND LOAD NOTE: A.PRECAST MANUFACTURER SHALL DESIGN PARAPET FOR ±38 PSF (ASD) WIND LOAD 203 PRECAST ROOF PANEL AT PRECAST CONCRETE WALL NO SCALE KEYNOTES: 1.PRECAST CONCRETE WALLS, SEE PLAN 2.1/4"x4"x4" EMBED PLATE W/ (1) 5 8"x5" HEADED STUD AT 32" O.C. 3.PRECAST ROOF PANEL, SEE PLAN NOTE: A.PRECAST MANUFACTURER SHALL DESIGN PARAPET FOR ±38 PSF (ASD) WIND LOAD 3 1 205 PRECAST ROOF PANEL AT PRECAST CONCRETE WALL NO SCALE 2 3" MIN BEARING 204 PRECAST ROOF PANEL AT PRECAST CONCRETE WALL NO SCALE KEYNOTES: 1.12" LONG #5 REBAR DOWEL AT 12" O.C. DRILL AND EPOXY INTO WALL W/ SIMPSON SET-3G EPOXY AND 6" EMBEDMENT INTO WALL 2.PRECAST ROOF PANEL, SEE PLAN 3.PRECAST CONCRETE WALLS, SEE PLAN 4.GROUT CELL SOLID, TYP 2 3 KEYNOTES: 1.#4 BENT DOWEL AT 48" O.C. STAGGERED EACH DIRECTION, DRILL AND EPOXY INTO WALL 10" 2.PRECAST ROOF PANEL, SEE PLAN 3.PRECAST CONCRETE WALLS, SEE PLAN 4.CONT 12" x 3" KOROLATH BEARING PAD OR EQUAL 5.36" LONG #4 BAR AT EACH BENT DOWEL 6.GROUT IN PLACE EVERY CELL WHERE THAT HAS A REBAR DOWEL, BREAK OUT HOLLOWCORE AS NEEDED TO INSERT REBAR 2 3 44 1 1 3/164 5 6 6 2 2 3/164 3/16 4 3/16 4 206 PRECAST ROOF PANEL AT PRECAST CONCRETE WALL NO SCALE KEYNOTES: 1.PRECAST CONCRETE WALLS, SEE PLAN 2.CONCRETE CORBEL BY PRECAST MANUFACTURER 3.CONT 12" x 3" KOROLATH BEARING PAD OR EQUAL 4.PRECAST ROOF PANEL, SEE PLAN 5.1/4"x4"x4" EMBED PLATE W/ (1) 5 8"x5" HEADED STUD AT 48" O.C. 6.12" LONG L4x4X1/4 ANGLE AT EACH EMBED PLATE 7.CONT L5x5x3 8 ANGLE W/ 5 8"Øx6" TITEN HD ANCHOR AT 16" O.C. 8.600S162-43 STEEL STUD JOIST AT 24" O.C. 9.12"x6" TITEN HD ANCHOR AT 4'-0" O.C. (EVERY OTHER JOIST) 10.7 16" ROOF SHEATHING W/ #6 SELF TAPPING SCREWS AT 6" O.C. 11. CONT 600T150-43 STEEL TRACK 12.3" LONG L3x3x14 ANGLE CLIP AT EACH ANCHOR 6" 4" MIN BEARING 1 2 3 4 5 NOTE: A.PRECAST MANUFACTURER SHALL DESIGN PARAPET FOR ±38 PSF (ASD) WIND LOAD 5 6 3/16 4 3" MIN BEARING 3 5 6 5 3/16 4 5 2" 7 98 10 207 PRECAST ROOF PANEL AT PRECAST CONCRETE WALL NO SCALE KEYNOTES: 1.PRECAST CONCRETE WALLS, SEE PLAN 2.1/4"x4"x4" EMBED PLATE W/ (1) 5 8"x5" HEADED STUD AT 8" O.C. 3.PRECAST ROOF PANEL, SEE PLAN NOTE: A.PRECAST MANUFACTURER SHALL DESIGN PARAPET FOR ±38 PSF (ASD) WIND LOAD 3 1 2 2 3/16 4 3/16 4 208 CONCRETE PANEL AT CONCRETE PANEL NO SCALE KEYNOTES: 1.PRECAST ROOF PANEL, SEE PLAN 2. #4 REBAR DOWEL AT SPACING SPECIFIED ON THE ROOF PLAN 3. GROUT IN PLACE EVERY CELL WHERE THAT HAS A REBAR DOWEL, BREAK OUT HOLLOWCORE AS NEEDED TO INSERT REBAR 3 1 2 209 PRECAST ROOF PANEL AT PRECAST CONCRETE WALL NO SCALE KEYNOTES: 1.1/4"x4"x4" EMBED PLATE W/ (1) 5 8"x5" HEADED STUD AT 48" O.C. 2.PRECAST CONCRETE WALLS, SEE PLAN 3.PRECAST ROOF PANEL, SEE PLAN 4.CONT 12" x 3" KOROLATH BEARING PAD OR EQUAL 5.CONCRETE CORBEL BY PRECAST MANUFACTURER 6.CONT L4x4X1/4 ANGLE 7.600S162-43 STEEL STUD JOIST AT 24" O.C. 8.12"x6" TITEN HD ANCHOR AT 4'-0" O.C. (EVERY OTHER JOIST) 9.7 16" ROOF SHEATHING W/ #6 SELF TAPPING SCREWS AT 6" O.C. 10.CONT 600T150-43 STEEL TRACK 11.3" LONG L3x3x14 ANGLE CLIP AT EACH ANCHOR 4" MIN BEARING 6" 2 3 1 5 4 NOTE: A.PRECAST MANUFACTURER SHALL DESIGN PARAPET FOR ±38 PSF (ASD) WIND LOAD 1 3/164 6 2'-0" 210 PRECAST ROOF PANEL AT PRECAST CONCRETE WALL NO SCALE KEYNOTES: 1.PRECAST CONCRETE WALLS, SEE PLAN 2.1/4"x4"x4" EMBED PLATE W/ (1) 5 8"x5" HEADED STUD AT 32" O.C. 3.PRECAST ROOF PANEL, SEE PLAN 4.C6x8.2 AT 24" O.C. 5.(2) 1 2"x5" TITEN HD ANCHOR 6.7 16" ROOF SHEATHING W/ #6 SELF TAPPING SCREWS AT 6" O.C. 7.600S162-43 STEEL STUD JOIST AT 24" O.C. 8.12"x6" TITEN HD ANCHOR AT 4'-0" O.C. (EVERY OTHER JOIST) 9.7 16" ROOF SHEATHING W/ #6 SELF TAPPING SCREWS AT 6" O.C. 10.CONT 600T150-43 STEEL TRACK 11.3" LONG L3x3x14 ANGLE CLIP AT EACH ANCHOR NOTE: A.PRECAST MANUFACTURER SHALL DESIGN PARAPET FOR ±38 PSF (ASD) WIND LOAD 3 1 2 2 3/16 4 3/16 4 1 6 15" 14 " 1/8 1111 12 10" 10 " 10 " 1 8 7 9 2'-0"10 10 1/8 11 8 7 9 10 10 1/4 11 2'-0" 211 NEW STEEL AWNING AT PRECAST CONCRETE WALL NO SCALE 4'-0" MAX 3/16 3" 3/16 3" 3/16 3" 3/16 3" KEYNOTES: 1.PRECAST CONCRETE WALLS, SEE PLAN 2.PL4x6x3 16 W/ (2) 12" Ø TITEN HD ANCHORS. INSTALL PLATE CENTERED ON SUPPORT ROD SPACING AS INDICATED ON WALL ELEVATIONS 3.3 16" STEEL ATTACHMENT PLATE W/ SHAPE PER ARCH. 4.1" DIAMETER SUPPORT ROD W/ THREADED ENDS FOR CLEVIS ATTACHMENT. SPACING PER WALL ELEVATIONS 5.ROOFING AND ATTACHMENT PER ARCH 6.C8x11.5 STEEL JOISTS AT 24" O.C. 7.HSS12x3x14 FRAME. ANCHOR TO WALL W/ 3 4" Ø TITEN HD ANCHORS AT 48" O.C. MAX. PRESTRESS PANEL STRANDS. MITER ALL CORNERS WITH FULL PENETRATION WELD. 1 3 2 3 4 5 6 7 7 3/16 3/16 3/16 3/16 1" EQ EQ 4 6 PR O F ES S I O N A L ENGI N E E R S TATE O F I D A HO A 9/ 7 / 2 3 14 1 3 4 D VID B . P O R T ER L I C E N SED 40 1 E A S T 1 7 0 0 S O U T H , S A L T L A K E C I T Y , U T A H ( 8 0 1 ) 4 8 4 - 2 0 4 6 AR C H I T E C T S A N D P L A N N E R S VI N C E N T D E S I G N G R O U P , I N C . T A G G N G O C A R W A S H S4.0 PROJECT MANAGER: CAD OPERATOR:JOB NO.: fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 Structural Engineering phone: 208.227.8404 This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. contact@frost-structural.com AVJHIF23-388 21 ' - 0 1 2" 149'-3" 4'-10" 1" 9'-11" 1" 9'-11" 1" 9'-11" 1" 9'-11" 1" 9'-11" 1" 9'-11" 1" 9'-11" 1" 9'-11" 1"9'-111 2"1"9'-111 2" 1' - 0 " TY P 6" TY P 2'-0" TYP 10" TYP 4'-3" TYP 2'-0" TYP 10" TYP EQ EQ 2'-0" 10 1 2" H - TUNNEL INTERIOR WALL GRADE 100'-0" 2' - 0 12" TY P 28 ' - 1 1 " 1"9'-111 2"9'-21 2"1" 19 ' - 8 1 4" STEEL EMBED PLATE WP17A WP17WP18WP19WP20WP20WP20WP20WP20WP20AWP21WP22WP23 WP24WP25 19'-3" C - TUNNEL NORTH WALL GRADE 100'-0" STEEL EMBED PLATE WP35WP36WP37WP38WP37AWP39WP40WP37WP38WP37CWP37BWP37WP37 21 ' - 0 1 2" 9'-111 2"1"9'-111 2"9'-41 4"9'-41 4"9'-41 4"9'-41 4"9'-41 4"9'-41 4"9'-41 8"9'-41 4"9'-111 2"9'-111 2"1"1"1"1"1"1"1"1"1"1" 150'-0" 9'-41 8"1" 20'-0" 16 ' - 1 0 34" 4' - 1 34" STEEL EMBED PLATE NWP1 NWP1 NWP1 1"1"1" 8'-3"8'-3"8'-3" 9' - 1 3 4" 1"1" 8'-3"8'-3"8'-3" 1"1" NWP2 NWP2 NWP2 16 ' - 5 1 2" 2' - 1 1 3 4" TY P 4" TY P 1'-10" TYP 4" TYP 3'-11" TYP 1'-10" TYP 4" TYP A - EQUIPMENT SOUTH WALL B - OFFICE SOUTH WALL GRADE 100'-0" BOTTOM OF DOOR AT GRADE WP4WP3WP2WP1 WP5 WP13WP12WP11 WP10 WP8WP7 WP14WP8WP8WP9WP8AWP8WP8 19 ' - 0 12" 8'-11" 1" 8'-11"9'-11"9'-11"9'-11"7'-51 2"7'-10"7'-51 2"9'-11"9'-11"9'-11"9'-11" 1"1"1"1"1"1"1"1"1"1" 24'-0"110'-11" 3'-111 2"4'-111 2"4'-111 2"3'-111 2" 19 ' - 0 12"16 ' - 1 12" 2' - 1 1 " 16 ' - 0 14" 3' - 0 38" STEEL EMBED PLATE STEEL EMBED PLATE 2' - 1 1 3 4" TY P 4" TY P 1'-10" TYP 4" TYP 3'-11" TYP 1'-10" TYP 4" TYP AWNING PER DETAIL. LOCATE ALL ELEMENTS ACCORDING TO THIS DRAWING AWNING PER DETAIL. LOCATE ALL ELEMENTS ACCORDING TO THIS DRAWING AWNING PER DETAIL. LOCATE ALL ELEMENTS ACCORDING TO THIS DRAWING 6'-101 4" 1'-3"4'-9" 8'-51 4" 81 4"4'-9" 3' - 3 " T Y P 2'-33 4" 3'-9" 2'-43 4" 3'-9" 3' - 3 " T Y P 13'-21 2"17'-71 2"2'-13 8"2'-0" 3' - 3 " T Y P 4'-0"4'-0" SCALE: ELEVATIONS 1/8" = 1'-0" PROJECT MANAGER: CAD OPERATOR:JOB NO.: fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 Structural Engineering phone: 208.227.8404 This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. contact@frost-structural.com AVJHIF23-388 PR O F ES S I O N A L ENGI N E E R STATE O F I D A HO A 9/ 7 / 2 3 14 1 3 4 D VID B . P O R T ER L I C E N SED 40 1 E A S T 1 7 0 0 S O U T H , S A L T L A K E C I T Y , U T A H ( 8 0 1 ) 4 8 4 - 2 0 4 6 AR C H I T E C T S A N D P L A N N E R S VI N C E N T D E S I G N G R O U P , I N C . T A G G N G O C A R W A S H S5.0 P lat h as not been approv ed y et. I need it approv ed prior to building/S ite P lan approv al. P lease submit full S ite P lan for approv al