HomeMy WebLinkAboutSUBGRADE INSPECTIONS - 23-00669 - Tagg N Go - Car WashInspection Details Date Contractor Inspector Weather Permit Number 11/21/2023 Jerome Bowen Construction Sanderson, James Cool Not provided Geotechnical Report Was Completed By:Atlas Report Date:12/01/2021 Report Number:E212744g Page Number:7 Site Plan Documentation Plan Sheet(s)Not provided Detail(s)/Note(s)Not provided RFI(s) Bearing Capacity Plans (If Applicable) Bearing Capacity Geotech (If Applicable)2500 psf Subgrade Compaction Required Yes No If Compaction is Required, Which Standard?ASTM D698 ASTM D1557 AASHTO T99 AASHTO T180 Idaho T74 WSDOT TM606 % Required Other Requirements(s) (e.g. Geogrid, Over­Ex, Etc.) Element(s) Inspected:Building Pad Columns Floor Slab Footings Pavement Infiltration Facility Other (specify below) Area(s)/Location(s) of Inspection: Car wash building pad ✔ ✔ Subgrade Inspection ­01Report #: 11/22/2023Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: Twin Towers, LLC 15464 Midnight view way Bluffdale, UT 84065 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 NOTICE: Our firm’s professionals are represented on site solely to observe operations of the contractor identified, to form opinions about the adequacy of those operations, and to report those opinions to our client. The presence and activities of our field representatives do not relieve any contractor from its obligation to meet contractual requirements. No one except our client may rely on our findings and opinions. The contractor retains sole responsibility for site safety and the methods, operations, and sequences of construction. ATL­NDT­F­200C Fab Shop Examination Report Rev 04/2021 Page 1 of 4Page 1 of 3 Inspection DetailsDateContractor Inspector Weather Permit Number11/21/2023 Jerome BowenConstruction Sanderson, James Cool Not providedGeotechnical Report Was Completed By:AtlasReport Date:12/01/2021 Report Number:E212744g Page Number:7Site Plan DocumentationPlan Sheet(s)Not providedDetail(s)/Note(s)Not providedRFI(s)Bearing Capacity Plans (If Applicable)Bearing Capacity Geotech (If Applicable)2500 psfSubgrade Compaction Required Yes NoIf Compaction is Required, Which Standard?ASTM D698 ASTM D1557 AASHTO T99AASHTO T180 Idaho T74 WSDOT TM606% Required Other Requirements(s) (e.g. Geogrid, Over­Ex, Etc.) Element(s) Inspected:Building Pad Columns Floor Slab Footings Pavement Infiltration Facility Other (specify below) Area(s)/Location(s) of Inspection: Car wash building pad Exposed Subgrade Soil Type(s):Silty sandwith gravel Fill:No Native:Yes Unstable:Yes No Probed:Yes No Soft:Yes No Proof Rolled:Yes No Equipment Used:Fully loaded Tandem axle dump truck Deflection Observed:Yes No Comments: Inspector arrived onsite to observe the proof roll of the building pad. A fully loaded dump truck was used. No deflection or pumping was observed. At the time of observing all material was firm and unyielding. Gene with Jerome Bowen was informed onsite of results. An email was sent to all authorized recipients. A sample of native material was taken for a proctor. Work inspected was:in compliance in compliance, except as noted in comments section reinspection/retesting required This assessment is limited in scope to the surface soils/materials exposed at the time of inspection, and available project­specic information provided to us. Subsurface conditions beneath or beyond whatis listed above are outside Altas’ scope of work. The inspection service provided does not address any geologic conditions, hazards, subsurface conditions, and/or area­wide geotechnical conditions. Note: The recording of false, fictitious, or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Photo Documentation Below ✔ ✔ ✔ ✔✔ ✔ ✔ ✔ Subgrade Inspection ­01Report #: 11/22/2023Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: Twin Towers, LLC 15464 Midnight view way Bluffdale, UT 84065 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 NOTICE: Our firm’s professionals are represented on site solely to observe operations of the contractor identified, to form opinions about the adequacy of those operations, and to report those opinions to our client. The presence and activities of our field representatives do not relieve any contractor from its obligation to meet contractual requirements. No one except our client may rely on our findings and opinions. The contractor retains sole responsibility for site safety and the methods, operations, and sequences of construction. ATL­NDT­F­200C Fab Shop Examination Report Rev 04/2021 Page 2 of 4Page 2 of 3 Inspection DetailsDateContractor Inspector Weather Permit Number11/21/2023 Jerome BowenConstruction Sanderson, James Cool Not providedGeotechnical Report Was Completed By:AtlasReport Date:12/01/2021 Report Number:E212744g Page Number:7Site Plan DocumentationPlan Sheet(s)Not providedDetail(s)/Note(s)Not providedRFI(s)Bearing Capacity Plans (If Applicable)Bearing Capacity Geotech (If Applicable)2500 psfSubgrade Compaction Required Yes NoIf Compaction is Required, Which Standard?ASTM D698 ASTM D1557 AASHTO T99AASHTO T180 Idaho T74 WSDOT TM606% RequiredOther Requirements(s) (e.g. Geogrid, Over­Ex, Etc.)Element(s) Inspected:Building Pad Columns Floor Slab Footings Pavement Infiltration FacilityOther (specify below)Area(s)/Location(s) of Inspection:Car wash building padExposed Subgrade Soil Type(s):Silty sandwith gravel Fill:No Native:YesUnstable:Yes NoProbed:Yes No Soft:Yes NoProof Rolled:Yes No Equipment Used:Fully loaded Tandem axle dump truckDeflection Observed:Yes NoComments:Inspector arrived onsite to observe the proof roll of the building pad. A fully loaded dump truck was used. No deflection or pumpingwas observed. At the time of observing all material was firm and unyielding. Gene with Jerome Bowen was informed onsite ofresults. An email was sent to all authorized recipients. A sample of native material was taken for a proctor.Work inspected was:in compliance in compliance, except as noted in comments section reinspection/retesting required This assessment is limited in scope to the surface soils/materials exposed at the time of inspection, and available project­specic information provided to us. Subsurface conditions beneath or beyond whatis listed above are outside Altas’ scope of work. The inspection service provided does not address any geologic conditions, hazards, subsurface conditions, and/or area­wide geotechnical conditions. Note: The recording of false, fictitious, or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Photo Documentation Below Building pad of car wash ✔✔✔✔✔✔✔✔ Subgrade Inspection ­01Report #: 11/22/2023Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: Twin Towers, LLC 15464 Midnight view way Bluffdale, UT 84065 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 NOTICE: Our firm’s professionals are represented on site solely to observe operations of the contractor identified, to form opinions about the adequacy of those operations, and to report those opinions to our client. The presence and activities of our field representatives do not relieve any contractor from its obligation to meet contractual requirements. No one except our client may rely on our findings and opinions. The contractor retains sole responsibility for site safety and the methods, operations, and sequences of construction. ATL­NDT­F­200C Fab Shop Examination Report Rev 04/2021 Page 3 of 4Page 3 of 3 Inspection Details Date Contractor Inspector Weather Permit Number 11/21/2023 Jerome Bowen Construction Sanderson, James Cool Not provided Geotechnical Report Was Completed By:Atlas Report Date:12/01/2021 Report Number:E212744g Page Number:7 Site Plan Documentation Plan Sheet(s)Not provided Detail(s)/Note(s)Not provided RFI(s) Bearing Capacity Plans (If Applicable) Bearing Capacity Geotech (If Applicable)2500 psf Subgrade Compaction Required Yes No If Compaction is Required, Which Standard?ASTM D698 ASTM D1557 AASHTO T99 AASHTO T180 Idaho T74 WSDOT TM606 % Required Other Requirements(s) (e.g. Geogrid, Over­Ex, Etc.) Element(s) Inspected:Building Pad Columns Floor Slab Footings Pavement Infiltration Facility Other (specify below) Area(s)/Location(s) of Inspection: Car wash building pad ✔ ✔ Subgrade Inspection ­00Report #: 11/21/2023Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: Twin Towers, LLC 15464 Midnight view way Bluffdale, UT 84065 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 This report shall not be reproduced, in full, without prior written approval of Atlas Technical Consultants, LLC. Results only relate to the items inspected or tested. Page 1 of 4Page 1 of 3 Inspection DetailsDateContractor Inspector Weather Permit Number11/21/2023 Jerome BowenConstruction Sanderson, James Cool Not providedGeotechnical Report Was Completed By:AtlasReport Date:12/01/2021 Report Number:E212744g Page Number:7Site Plan DocumentationPlan Sheet(s)Not providedDetail(s)/Note(s)Not providedRFI(s)Bearing Capacity Plans (If Applicable)Bearing Capacity Geotech (If Applicable)2500 psfSubgrade Compaction Required Yes NoIf Compaction is Required, Which Standard?ASTM D698 ASTM D1557 AASHTO T99AASHTO T180 Idaho T74 WSDOT TM606% Required Other Requirements(s) (e.g. Geogrid, Over­Ex, Etc.) Element(s) Inspected:Building Pad Columns Floor Slab Footings Pavement Infiltration Facility Other (specify below) Area(s)/Location(s) of Inspection: Car wash building pad Exposed Subgrade Soil Type(s):Silty sandwith gravel Fill:No Native:Yes Unstable:Yes No Probed:Yes No Soft:Yes No Proof Rolled:Yes No Equipment Used:Fully loaded Tandem axle dump truck Deflection Observed:Yes No Comments: Inspector arrived onsite to observe the proof roll of the building pad. A fully loaded dump truck was used. No deflection or pumping was observed. At the time of observing all material was firm and unyielding. Gene with Jerome Bowen was informed onsite of results. A email was sent to all authorized recipients. A sample of native material was taken for a proctor. Work inspected was:in compliance in compliance, except as noted in comments section reinspection/retesting required This assessment is limited in scope to the surface soils/materials exposed at the time of inspection, and available project­specic information provided to us. Subsurface conditions beneath or beyond whatis listed above are outside Altas’ scope of work. The inspection service provided does not address any geologic conditions, hazards, subsurface conditions, and/or area­wide geotechnical conditions. Note: The recording of false, fictitious, or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Photo Documentation Below ✔ ✔ ✔ ✔✔ ✔ ✔ ✔ Subgrade Inspection ­00Report #: 11/21/2023Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: Twin Towers, LLC 15464 Midnight view way Bluffdale, UT 84065 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 This report shall not be reproduced, in full, without prior written approval of Atlas Technical Consultants, LLC. Results only relate to the items inspected or tested. Page 2 of 4Page 2 of 3 Inspection DetailsDateContractor Inspector Weather Permit Number11/21/2023 Jerome BowenConstruction Sanderson, James Cool Not providedGeotechnical Report Was Completed By:AtlasReport Date:12/01/2021 Report Number:E212744g Page Number:7Site Plan DocumentationPlan Sheet(s)Not providedDetail(s)/Note(s)Not providedRFI(s)Bearing Capacity Plans (If Applicable)Bearing Capacity Geotech (If Applicable)2500 psfSubgrade Compaction Required Yes NoIf Compaction is Required, Which Standard?ASTM D698 ASTM D1557 AASHTO T99AASHTO T180 Idaho T74 WSDOT TM606% RequiredOther Requirements(s) (e.g. Geogrid, Over­Ex, Etc.)Element(s) Inspected:Building Pad Columns Floor Slab Footings Pavement Infiltration FacilityOther (specify below)Area(s)/Location(s) of Inspection:Car wash building padExposed Subgrade Soil Type(s):Silty sandwith gravel Fill:No Native:YesUnstable:Yes NoProbed:Yes No Soft:Yes NoProof Rolled:Yes No Equipment Used:Fully loaded Tandem axle dump truckDeflection Observed:Yes NoComments:Inspector arrived onsite to observe the proof roll of the building pad. A fully loaded dump truck was used. No deflection or pumpingwas observed. At the time of observing all material was firm and unyielding. Gene with Jerome Bowen was informed onsite ofresults. A email was sent to all authorized recipients. A sample of native material was taken for a proctor.Work inspected was:in compliance in compliance, except as noted in comments section reinspection/retesting required This assessment is limited in scope to the surface soils/materials exposed at the time of inspection, and available project­specic information provided to us. Subsurface conditions beneath or beyond whatis listed above are outside Altas’ scope of work. The inspection service provided does not address any geologic conditions, hazards, subsurface conditions, and/or area­wide geotechnical conditions. Note: The recording of false, fictitious, or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Photo Documentation Below Building pad of car wash ✔✔✔✔✔✔✔✔ Subgrade Inspection ­00Report #: 11/21/2023Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: Twin Towers, LLC 15464 Midnight view way Bluffdale, UT 84065 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 This report shall not be reproduced, in full, without prior written approval of Atlas Technical Consultants, LLC. Results only relate to the items inspected or tested. Page 3 of 4Page 3 of 3