HomeMy WebLinkAboutSOIL DENSITY - 23-00669 - Tagg N Go - Car WashTest Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 89 Base Course: Sidewalk: Sub base for sidewalk along Northside of Tagg n go building. 3¶North from Northeast corner of building this position will serve as station 00+00 running East. Station 00+06 1¶right of center. 0.0 Feet below sub base InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 90 Base Course: Sidewalk: Sub base for sidewalk along Northside of Tagg n go building. 3¶North from Northeast corner of building this position will serve as station 00+00 running East. Station 00+35 1¶left of center. 0.0 Feet below sub base InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 91 Base Course: Sidewalk: Sub base for sidewalk along Northside of Tagg n go building. 3¶North from Northeast corner of building this position will serve as station 00+00 running East. Station 00+63 2¶left of center. 0.0 Feet below sub base InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 92 Base Course: Sidewalk: Sub base for sidewalk along Northside of Tagg n go building. 3¶North from Northeast corner of building this position will serve as station 00+00 running East. Station 00+95 2¶right of center. 0.0 Feet below sub base InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 93 Base Course: Sidewalk: Sub base for sidewalk along Northside of Tagg n go building. 3¶North from Northeast corner of building this position will serve as station 00+00 running East. Station 01+24 1¶right of center. 0.0 Feet below sub base InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 89, 90, 91, 92, 93: Atlas representative informed Gino with Jerome Bowen Construction of testing results. Email will be sent to all authorized recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 89 07/31/24 23-7428 D1557 C SM 8.6 124.6 1.4 118.1 119.8 Backsca tter 95 95 DP 90 07/31/24 23-7428 D1557 C SM 8.6 124.6 1.3 120.8 122.4 Backsca tter 97 95 DP 91 07/31/24 23-7428 D1557 C SM 8.6 124.6 1.7 118.7 120.7 Backsca tter 95 95 DP 92 07/31/24 23-7428 D1557 C SM 8.6 124.6 2.1 119.3 121.8 Backsca tter 96 95 DP 93 07/31/24 23-7428 D1557 C SM 8.6 124.6 2.1 119.3 121.8 Backsca tter 96 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 07/31/2024 Report #: SNG-000008-01 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Page 1 of 2 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 2 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 07/31/2024 Report #: SNG-000008-01 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Page 2 of 2 Reviewed and Approved by: John Franson 07/31/2024 Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 94 Base Course: Paving (asphalt): From very NE pay station ¶N ¶E 3.0 Inches below finished grade Troxler / 3440 / 26708 / 01/31/2024 Mathie, Caysen 95 Base Course: Paving (asphalt): From very NE pay station ¶N ¶E 3.0 Inches below finished grade Troxler / 3440 / 26708 / 01/31/2024 Mathie, Caysen 96 Base Course: Paving (asphalt): From Moody Road street light ¶W ¶N 3.0 Inches below finished grade Troxler / 3440 / 26708 / 01/31/2024 Mathie, Caysen 97 Base Course: Paving (asphalt): NW main entrance ¶S ¶E 3.0 Inches below finished grade Troxler / 3440 / 26708 / 01/31/2024 Mathie, Caysen 98 Base Course: Paving (asphalt): NW main entrance ¶S ¶E 3.0 Inches below finished grade Troxler / 3440 / 26708 / 01/31/2024 Mathie, Caysen 99 Base Course: Paving (asphalt): NW main entrance ¶S ¶E 3.0 Inches below finished grade Troxler / 3440 / 26708 / 01/31/2024 Mathie, Caysen Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 94, 95, 96, 97, 98, 99: Atlas cannot atest to the validity of the client provided proctor. Atlas rep informed Gene with Jerome Bowen of test results, email sent to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 94 08/02/24 CP 22-59 D698 C GP 4.9 135.7 4.2 130.6 136.1 2 96 95 DP 95 08/02/24 CP 22-59 D698 C GP 4.9 135.7 4.2 129.2 134.6 2 95 95 DP 96 08/02/24 CP 22-59 D698 C GP 4.9 135.7 2.4 129.5 132.6 2 95 95 DP 97 08/02/24 CP 22-59 D698 C GP 4.9 135.7 3.7 134.4 139.4 2 99 95 DP 98 08/02/24 CP 22-59 D698 C GP 4.9 135.7 5.6 141.6 149.6 2 104 95 DP 99 08/02/24 CP 22-59 D698 C GP 4.9 135.7 6.0 137.4 145.7 2 101 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 08/02/2024 Report #: SNG-000009-00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Reviewed and Approved by: John Franson 08/02/2024 Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 100 Base Course: Paving (concrete): ¶e ¶s from the most south pay station.3.0 Inches below finished grade InstroTex / 3500 / 4555 / 01/09/2024 Mathie, Caysen 101 Base Course: Paving (concrete): ¶e ¶s from the most south pay station.3.0 Inches below finished grade InstroTex / 3500 / 4555 / 01/09/2024 Mathie, Caysen 102 Base Course: Paving (concrete): ¶e ¶s from the most south pay station 90* turn.3.0 Inches below finished grade InstroTex / 3500 / 4555 / 01/09/2024 Mathie, Caysen 103 Base Course: Paving (concrete): ¶w ¶s from the most south pay station.3.0 Inches below finished grade InstroTex / 3500 / 4555 / 01/09/2024 Mathie, Caysen 104 Base Course: Paving (concrete): ¶w ¶s from the most south pay station 90* turn.3.0 Inches below finished grade InstroTex / 3500 / 4555 / 01/09/2024 Mathie, Caysen Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 100, 101, 102, 103, 104: Atlas cannot attest to the validity of the client provided proctor. Atlas rep informed Geno with Jerome Bowen of test results. Email sent to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 100 08/05/24 CP 22-59 D698 C GP 4.9 135.7 2.3 130.1 133.1 2 96 95 DP 101 08/05/24 CP 22-59 D698 C GP 4.9 135.7 4.0 129.1 134.3 2 95 95 DP 102 08/05/24 CP 22-59 D698 C GP 4.9 135.7 4.2 129.2 134.6 2 95 95 DP 103 08/05/24 CP 22-59 D698 C GP 4.9 135.7 4.5 128.5 134.3 2 95 95 DP 104 08/05/24 CP 22-59 D698 C GP 4.9 135.7 3.1 129.9 133.9 2 96 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 08/06/2024 Report #: SNG-000010-00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Reviewed and Approved by: John Franson 08/06/2024 Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 3 Structural Fill: Interior Slab-on-Grade: All density tests today were within the main slab on grade structure. 18' E 3' S off CL of West wall 18.0 Inches Below Finished Grade InstroTex / 3500 / 4555 / 01/09/2024 Smith, Kyle 4 Structural Fill: Interior Slab-on-Grade: All density tests today were within the main slab on grade structure. 96' E 7' S off CL of West wall 18.0 Inches Below Finished Grade InstroTex / 3500 / 4555 / 01/09/2024 Smith, Kyle 5 Structural Fill: Interior Slab-on-Grade: All density tests today were within the main slab on grade structure. 117' E 6' S off CL of West wall 6.0 Inches Below Finished Grade InstroTex / 3500 / 4555 / 01/09/2024 Smith, Kyle 6 Structural Fill: Interior Slab-on-Grade: All density tests today were within the main slab on grade structure. 24' E 5' S off CL of West wall 6.0 Inches Below Finished Grade InstroTex / 3500 / 4555 / 01/09/2024 Smith, Kyle Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 3, 4, 5, 6: Atlas inspector informed Gene Bates with Jerome Bowmen Construction of all-density test results. Atlas inspector also informed Gene of compaction results over 102% which could indicate a material change and that a new proctor may be required. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 3 02/14/24 CP 22-59 C GP 4.9 135.7 4.5 143.3 149.8 6 106 95 DP 4 02/14/24 CP 22-59 C GP 4.9 135.7 4.8 141.7 148.5 6 104 95 DP 5 02/14/24 CP 22-59 C GP 4.9 135.7 3.4 140.5 145.3 6 104 95 DP 6 02/14/24 CP 22-59 C GP 4.9 135.7 3.9 137.4 142.7 6 101 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results FRPSO\ZLWKWKHDFFHSWDQFHFULWHULDLQWKHPRVWUHFHQWFOLHQWDSSURYHGSURMHFWSODQVDQGVSHFLILFDWLRQV:HXVHWKHVLPSOHDFFHSWDQFHUHMHFWLRQGHFLVLRQUXOH accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 02/14/2024 Report #: -00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 3 Structural Fill: Interior Slab-on-Grade: All density tests today were within the main slab on grade structure. 18' E 3' S off CL of West wall 18.0 Inches Below Finished Grade InstroTex / 3500 / 4555 / 01/09/2024 Smith, Kyle 4 Structural Fill: Interior Slab-on-Grade: All density tests today were within the main slab on grade structure. 96' E 7' S off CL of West wall 18.0 Inches Below Finished Grade InstroTex / 3500 / 4555 / 01/09/2024 Smith, Kyle 5 Structural Fill: Interior Slab-on-Grade: All density tests today were within the main slab on grade structure. 117' E 6' S off CL of West wall 6.0 Inches Below Finished Grade InstroTex / 3500 / 4555 / 01/09/2024 Smith, Kyle 6 Structural Fill: Interior Slab-on-Grade: All density tests today were within the main slab on grade structure. 24' E 5' S off CL of West wall 6.0 Inches Below Finished Grade InstroTex / 3500 / 4555 / 01/09/2024 Smith, Kyle Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 3, 4, 5, 6: Atlas inspector informed Gene Bates with Jerome Bowmen Construction of all-density test results. Atlas inspector also informed Gene of compaction results over 102% which could indicate a material change and that a new proctor may be required. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 3 02/14/24 CP 22-59 C GP 4.9 135.7 4.5 143.3 149.8 6 106 95 DP 4 02/14/24 CP 22-59 C GP 4.9 135.7 4.8 141.7 148.5 6 104 95 DP 5 02/14/24 CP 22-59 C GP 4.9 135.7 3.4 140.5 145.3 6 104 95 DP 6 02/14/24 CP 22-59 C GP 4.9 135.7 3.9 137.4 142.7 6 101 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results FRPSO\ZLWKWKHDFFHSWDQFHFULWHULDLQWKHPRVWUHFHQWFOLHQWDSSURYHGSURMHFWSODQVDQGVSHFLILFDWLRQV:HXVHWKHVLPSOHDFFHSWDQFHUHMHFWLRQGHFLVLRQUXOH accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 02/15/2024 Report #: -01 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 7 Structural Fill: Interior Wall Backfill: ¶wide strip along the North wall 50 feet from West entrance 2.0 Feet below top of stem wall Troxler / 3440 / 26708 / 01/31/2024 Neibaur, Rick 8 Structural Fill: Interior Wall Backfill: ¶wide strip along the North wall 50 feet from West entrance 2.0 Feet below top of stem wall Troxler / 3440 / 26708 / 01/31/2024 Neibaur, Rick Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 7, 8: Gene with Jerome Bowen was notified of test results. Email sent to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 7 02/28/24 23-7428 C SM 8.6 124.6 2.6 118.6 121.7 6 95 95 DP 8 02/28/24 23-7428 C SM 8.6 124.6 5.1 120.2 126.3 6 96 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results FRPSO\ZLWKWKHDFFHSWDQFHFULWHULDLQWKHPRVWUHFHQWFOLHQWDSSURYHGSURMHFWSODQVDQGVSHFLILFDWLRQV:HXVHWKHVLPSOHDFFHSWDQFHUHMHFWLRQGHFLVLRQUXOH accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 03/01/2024 Report #: -00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 9 Subgrade: Building Pad: From south east corner of car wash ¶N and ¶W 18.0 Inches below finish grade Troxler / 3430 / 27237 / 01/23/2024 Lake, Noah 10 Subgrade: Building Pad: From south east corner of car wash ¶N and ¶W 6.0 Inches below finish grade Troxler / 3430 / 27237 / 01/23/2024 Lake, Noah Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 9, 10: Atlas Rep Noah Lake informed Gene with Jerome Bowen the results for the density test. Emailed all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 9 02/29/24 23-7428 C SM 8.6 124.6 7.1 126.7 135.7 8 102 95 DP 10 02/29/24 23-7428 C SM 8.6 124.6 5.7 129.2 136.5 8 104 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results FRPSO\ZLWKWKHDFFHSWDQFHFULWHULDLQWKHPRVWUHFHQWFOLHQWDSSURYHGSURMHFWSODQVDQGVSHFLILFDWLRQV:HXVHWKHVLPSOHDFFHSWDQFHUHMHFWLRQGHFLVLRQUXOH accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 03/01/2024 Report #: -01 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 9 Subgrade: Building Pad: From south east corner of car wash ¶N and ¶W 18.0 Inches below finish grade Troxler / 3430 / 27237 / 01/23/2024 Lake, Noah 10 Subgrade: Building Pad: From south east corner of car wash ¶N and ¶W 6.0 Inches below finish grade Troxler / 3430 / 27237 / 01/23/2024 Lake, Noah Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 9, 10: Atlas Rep Noah Lake informed Gene with Jerome Bowen the results for the density test. Emailed all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 9 02/29/24 23-7428 C SM 8.6 124.6 7.1 126.7 135.7 8 102 95 DP 10 02/29/24 23-7428 C SM 8.6 124.6 5.7 129.2 136.5 8 104 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results FRPSO\ZLWKWKHDFFHSWDQFHFULWHULDLQWKHPRVWUHFHQWFOLHQWDSSURYHGSURMHFWSODQVDQGVSHFLILFDWLRQV:HXVHWKHVLPSOHDFFHSWDQFHUHMHFWLRQGHFLVLRQUXOH accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 02/29/2024 Report #: -00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 11 Trench Backfill: Sanitary Sewer: 1 ft N 43 ft E of the T juction,12.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 12 Trench Backfill: Sanitary Sewer: 2 ft N 3 ft E of T junction 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 13 Trench Backfill: Sanitary Sewer: 3 ft N 11 ft E of T junction 36.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 14 Trench Backfill: Sanitary Sewer: 8 ft S 5 ft W of T junction 24.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 15 Trench Backfill: Sanitary Sewer: 45 ft S 5 ft of west middle manhole 18.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 16 Trench Backfill: Sanitary Sewer: 105 ft S 7 ft E of west middle manhole 12.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 11, 12, 13, 14, 15, 16: Dillon with Jerome Bowen was notified onsite of results. Email will be sent out to all authorized recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 11 03/07/24 23-7428 C SM 8.6 124.6 4.7 124.8 130.7 12 100 95 DP 12 03/07/24 23-7428 C SM 8.6 124.6 4.1 121.8 126.8 8 98 95 DP 13 03/07/24 23-7428 C SM 8.6 124.6 4.8 126.2 132.2 8 101 95 DP 14 03/07/24 23-7428 C SM 8.6 124.6 5.6 126.3 133.4 8 101 95 DP 15 03/07/24 23-7428 C SM 8.6 124.6 5.9 127.4 134.9 8 102 95 DP 16 03/07/24 23-7428 C SM 8.6 124.6 7.5 118.7 127.6 8 95 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results FRPSO\ZLWKWKHDFFHSWDQFHFULWHULDLQWKHPRVWUHFHQWFOLHQWDSSURYHGSURMHFWSODQVDQGVSHFLILFDWLRQV:HXVHWKHVLPSOHDFFHSWDQFHUHMHFWLRQGHFLVLRQUXOH accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 03/08/2024 Report #: -01 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 11 Trench Backfill: Sanitary Sewer: 1 ft N 43 ft E of the T juction,12.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 12 Trench Backfill: Sanitary Sewer: 2 ft N 3 ft E of T junction 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 13 Trench Backfill: Sanitary Sewer: 3 ft N 11 ft E of T junction 36.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 14 Trench Backfill: Sanitary Sewer: 8 ft S 5 ft W of T junction 24.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 15 Trench Backfill: Sanitary Sewer: 45 ft S 5 ft of west middle manhole 18.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 16 Trench Backfill: Sanitary Sewer: 105 ft S 7 ft E of west middle manhole 12.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 11, 12, 13, 14, 15, 16: Dillon with Jerome Bowen was notified onsite of results. Email will be sent out to all authorized recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 11 03/07/24 23-7428 C SM 8.6 124.6 4.7 124.8 130.7 12 100 95 DP 12 03/07/24 23-7428 C SM 8.6 124.6 4.1 121.8 126.8 8 98 95 DP 13 03/07/24 23-7428 C SM 8.6 124.6 4.8 126.2 132.2 8 101 95 DP 14 03/07/24 23-7428 C SM 8.6 124.6 5.6 126.3 133.4 8 101 95 DP 15 03/07/24 23-7428 C SM 8.6 124.6 5.9 127.4 134.9 8 102 95 DP 16 03/07/24 23-7428 C SM 8.6 124.6 7.5 118.7 127.6 8 95 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results FRPSO\ZLWKWKHDFFHSWDQFHFULWHULDLQWKHPRVWUHFHQWFOLHQWDSSURYHGSURMHFWSODQVDQGVSHFLILFDWLRQV:HXVHWKHVLPSOHDFFHSWDQFHUHMHFWLRQGHFLVLRQUXOH accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 03/07/2024 Report #: -00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 17 Trench Backfill: Sanitary Sewer: 48 ft S then 5 ft W of manhole 2 36.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 18 Trench Backfill: Sanitary Sewer: 46 ft S then 3 ft W of manhole 2 36.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 19 Trench Backfill: Sanitary Sewer: 50 ft S 2 ft E of manhole 2 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 20 Trench Backfill: Sanitary Sewer: 47 ft S 4 ft E of manhole 2 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 17, 18, 19, 20: Notified Dillon with Jerome Bowen Construction of all inspection results. Email sent to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 17 03/14/24 23-7428 C SM 8.6 124.6 4.3 119.6 124.7 8 96 0 DP 18 03/14/24 23-7428 C SM 8.6 124.6 4.5 123.9 129.5 8 99 0 DP 19 03/14/24 23-7428 C SM 8.6 124.6 4.6 123.0 128.7 8 99 0 DP 20 03/14/24 23-7428 C SM 8.6 124.6 5.3 122.2 128.7 8 98 0 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 03/14/2024 Report #: -01 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Reviewed and Approved by: Troy Posio Project Manager 03/14/2024 Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 21 Trench Backfill: Sanitary Sewer: From southeast corner of sanitary sewer lift 4ft south then 4 ft north. 36.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 22 Trench Backfill: Sanitary Sewer: From southeast corner of sanitary sewer lift 4ft south then 2 ft north. 36.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 23 Trench Backfill: Sanitary Sewer: From southeast corner of sanitary sewer lift 5 ft south then 2 ft east. 24.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 24 Trench Backfill: Sanitary Sewer: From southeast corner of sanitary sewer lift 3 ft south then 4ft east. 24.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 25 Trench Backfill: Sanitary Sewer: From southeast corner of sanitary sewer lift 2 ft south then 3 ft east. 12.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 26 Trench Backfill: Sanitary Sewer: From southeast corner of sanitary sewer lift 3 ft south then 3 ft east. 12.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 21, 22, 23, 24, 25, 26: Dylan with Jerome as notified of inspection results. Email sent to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 21 03/28/24 23-7428 C SM 8.6 124.6 5.8 118.2 125.1 6 95 0 DP 22 03/28/24 23-7428 C SM 8.6 124.6 4.1 117.8 122.6 4 95 0 DP 23 03/28/24 23-7428 C SM 8.6 124.6 4.5 122.8 128.3 4 99 0 DP 24 03/28/24 23-7428 C SM 8.6 124.6 3.9 117.7 122.3 4 94 0 DP 25 03/28/24 23-7428 C SM 8.6 124.6 3.5 118.6 122.7 4 95 0 DP 26 03/28/24 23-7428 C SM 8.6 124.6 3.6 118.0 122.2 4 95 0 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 04/01/2024 Report #: -01 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Reviewed and Approved by: Troy Posio Project Manager 04/01/2024 Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 21 Trench Backfill: Sanitary Sewer: From southeast corner of sanitary sewer lift 4ft south then 4 ft north. 36.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 22 Trench Backfill: Sanitary Sewer: From southeast corner of sanitary sewer lift 4ft south then 2 ft north. 36.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 23 Trench Backfill: Sanitary Sewer: From southeast corner of sanitary sewer lift 5 ft south then 2 ft east. 24.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 24 Trench Backfill: Sanitary Sewer: From southeast corner of sanitary sewer lift 3 ft south then 4ft east. 24.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 25 Trench Backfill: Sanitary Sewer: From southeast corner of sanitary sewer lift 2 ft south then 3 ft east. 12.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 26 Trench Backfill: Sanitary Sewer: From southeast corner of sanitary sewer lift 3 ft south then 3 ft east. 12.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 21, 22, 23, 24, 25, 26: Dylan with Jerome as notified of inspection results. Email sent to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 21 03/28/24 23-7428 C SM 8.6 124.6 5.8 118.2 125.1 6 95 0 DP 22 03/28/24 23-7428 C SM 8.6 124.6 4.1 117.8 122.6 4 95 0 DP 23 03/28/24 23-7428 C SM 8.6 124.6 4.5 122.8 128.3 4 99 0 DP 24 03/28/24 23-7428 C SM 8.6 124.6 3.9 117.7 122.3 4 94 0 DP 25 03/28/24 23-7428 C SM 8.6 124.6 3.5 118.6 122.7 4 95 0 DP 26 03/28/24 23-7428 C SM 8.6 124.6 3.6 118.0 122.2 4 95 0 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 03/28/2024 Report #: -00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 27 Utility Trench Backfill: Water Main: 30 ft south of water main stump along water main trench. 60.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 28 Utility Trench Backfill: Water Main: 32 ft south of water main stump along water main trench. 60.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 29 Utility Trench Backfill: Water Main: 26 ft south of water main stump along water main trench. 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 30 Utility Trench Backfill: Water Main: 24 ft south of water main stump along water main trench. 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 31 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 72 ft north 60.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 32 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 69 ft north 60.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 33 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 20 ft north 60.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 34 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 22 ft north 60.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 27, 28, 29, 30, 31, 32, 33, 34: Dylan with Jerome Bowen as notified of inspection results. Email sent to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 27 04/03/24 23-7428 C SM 8.6 124.6 5.6 128.2 135.4 4 103 0 DP 28 04/03/24 23-7428 C SM 8.6 124.6 5.1 128.3 134.9 4 103 0 DP 29 04/03/24 23-7428 C SM 8.6 124.6 4.9 126.3 132.5 4 101 0 DP 30 04/03/24 23-7428 C SM 8.6 124.6 4.9 121.4 127.4 4 97 0 DP 31 04/03/24 23-7428 C SM 8.6 124.6 4.1 123.3 128.3 4 99 0 DP 32 04/03/24 23-7428 C SM 8.6 124.6 4.6 125.2 131.0 4 100 0 DP 33 04/03/24 23-7428 C SM 8.6 124.6 4.9 126.6 132.8 4 102 0 DP 34 04/03/24 23-7428 C SM 8.6 124.6 5.2 125.8 132.3 4 101 0 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 2 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 04/03/2024 Report #: -00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 35 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 76 ft north 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 36 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 72 ft north 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 37 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 62 ft north 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 38 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 40 ft north 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 39 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 26 ft north 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 40 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 22 ft north 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 41 Utility Trench Backfill: Water Main: 32 ft south of water main stump 36.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 42 Utility Trench Backfill: Water Main: 30 ft south of water main stump 36.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 35, 36, 37, 38, 39, 40, 41, 42: Dylan with Jerome Bowen as notified of inspection results. Email sent to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 35 04/03/24 23-7428 C SM 8.6 124.6 3.4 125.3 129.6 4 101 0 DP 36 04/03/24 23-7428 C SM 8.6 124.6 3.5 127.5 132.0 4 102 0 DP 37 04/03/24 23-7428 C SM 8.6 124.6 3.7 130.9 135.7 4 105 0 DP 38 04/03/24 23-7428 C SM 8.6 124.6 3.5 129.8 134.3 4 104 0 DP 39 04/03/24 23-7428 C SM 8.6 124.6 3.7 130.8 135.7 4 105 0 DP 40 04/03/24 23-7428 C SM 8.6 124.6 4.0 128.9 134.1 4 103 0 DP 41 04/03/24 23-7428 C SM 8.6 124.6 6.9 125.2 133.9 4 100 0 DP 42 04/03/24 23-7428 C SM 8.6 124.6 4.7 120.8 126.5 4 97 0 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 2 of 2 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 04/03/2024 Report #: -00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 27 Utility Trench Backfill: Water Main: 30 ft south of water main stump along water main trench. 60.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 28 Utility Trench Backfill: Water Main: 32 ft south of water main stump along water main trench. 60.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 29 Utility Trench Backfill: Water Main: 26 ft south of water main stump along water main trench. 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 30 Utility Trench Backfill: Water Main: 24 ft south of water main stump along water main trench. 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 31 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 72 ft north 60.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 32 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 69 ft north 60.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 33 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 20 ft north 60.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 34 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 22 ft north 60.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 27, 28, 29, 30, 31, 32, 33, 34: Dylan with Jerome Bowen as notified of inspection results. Email sent to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 27 04/03/24 23-7428 C SM 8.6 124.6 5.6 128.2 135.4 4 103 0 DP 28 04/03/24 23-7428 C SM 8.6 124.6 5.1 128.3 134.9 4 103 0 DP 29 04/03/24 23-7428 C SM 8.6 124.6 4.9 126.3 132.5 4 101 0 DP 30 04/03/24 23-7428 C SM 8.6 124.6 4.9 121.4 127.4 4 97 0 DP 31 04/03/24 23-7428 C SM 8.6 124.6 4.1 123.3 128.3 4 99 0 DP 32 04/03/24 23-7428 C SM 8.6 124.6 4.6 125.2 131.0 4 100 0 DP 33 04/03/24 23-7428 C SM 8.6 124.6 4.9 126.6 132.8 4 102 0 DP 34 04/03/24 23-7428 C SM 8.6 124.6 5.2 125.8 132.3 4 101 0 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 2 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 04/04/2024 Report #: -01 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Page 1 of 3 Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 35 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 76 ft north 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 36 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 72 ft north 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 37 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 62 ft north 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 38 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 40 ft north 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 39 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 26 ft north 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 40 Utility Trench Backfill: Water Main: 6 ft west of manhole 2 from that position to 22 ft north 48.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 41 Utility Trench Backfill: Water Main: 32 ft south of water main stump 36.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 42 Utility Trench Backfill: Water Main: 30 ft south of water main stump 36.0 Inches below grade InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 35, 36, 37, 38, 39, 40, 41, 42: Dylan with Jerome Bowen as notified of inspection results. Email sent to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 35 04/03/24 23-7428 C SM 8.6 124.6 3.4 125.3 129.6 4 101 0 DP 36 04/03/24 23-7428 C SM 8.6 124.6 3.5 127.5 132.0 4 102 0 DP 37 04/03/24 23-7428 C SM 8.6 124.6 3.7 130.9 135.7 4 105 0 DP 38 04/03/24 23-7428 C SM 8.6 124.6 3.5 129.8 134.3 4 104 0 DP 39 04/03/24 23-7428 C SM 8.6 124.6 3.7 130.8 135.7 4 105 0 DP 40 04/03/24 23-7428 C SM 8.6 124.6 4.0 128.9 134.1 4 103 0 DP 41 04/03/24 23-7428 C SM 8.6 124.6 6.9 125.2 133.9 4 100 0 DP 42 04/03/24 23-7428 C SM 8.6 124.6 4.7 120.8 126.5 4 97 0 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 2 of 2 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 04/04/2024 Report #: -01 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Page 2 of 3 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 3 of 2 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 04/04/2024 Report #: -01 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Page 3 of 3 Reviewed and Approved by: Troy Posio Project Manager 04/04/2024 Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 43 Trench Backfill: Sanitary Sewer: From water tank 2, ¶East, ¶North.12.0 Inches below finish grade. Troxler / 3440 / 18792 / 01/24/2024 Smith, Kyle 44 Trench Backfill: Sanitary Sewer: From the center of water tank 3, ¶North 30.0 Inches below finish grade. Troxler / 3440 / 18792 / 01/24/2024 Smith, Kyle 45 Trench Backfill: Sanitary Sewer: From the center of the grease tank catch, ¶North.18.0 Inches below finish grade. Troxler / 3440 / 18792 / 01/24/2024 Smith, Kyle 46 Trench Backfill: Sanitary Sewer: From the center of the grease tank catch, ¶North.18.0 Inches below finish grade. Troxler / 3440 / 18792 / 01/24/2024 Smith, Kyle 47 Trench Backfill: Sanitary Sewer: From the center water tank 2, ¶North.12.0 Inches below finish grade. Troxler / 3440 / 18792 / 01/24/2024 Smith, Kyle Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 43, 44, 45, 46, 47: Informed Dylan with Jerome Bowen Construction verbally of all results, emailed all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 43 04/04/24 23-7428 C SM 8.6 124.6 5.4 122.5 129.1 10 98 95 DP 44 04/04/24 23-7428 C SM 8.6 124.6 3.4 122.2 126.4 10 98 95 DP 45 04/04/24 23-7428 C SM 8.6 124.6 4.6 122.2 127.8 10 98 95 DP 46 04/04/24 23-7428 C SM 8.6 124.6 3.4 122.2 126.4 10 98 95 DP 47 04/04/24 23-7428 C SM 8.6 124.6 3.4 121.7 125.8 10 98 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 04/08/2024 Report #: -00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Reviewed and Approved by: Troy Posio Project Manager 04/08/2024 Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 43 Trench Backfill: Sanitary Sewer: From water tank 2, ¶East, ¶North.12.0 Inches below finish grade. Troxler / 3440 / 18792 / 01/24/2024 Smith, Kyle 44 Trench Backfill: Sanitary Sewer: From the center of water tank 3, ¶North 30.0 Inches below finish grade. Troxler / 3440 / 18792 / 01/24/2024 Smith, Kyle 45 Trench Backfill: Sanitary Sewer: From the center of the grease tank catch, ¶North.18.0 Inches below finish grade. Troxler / 3440 / 18792 / 01/24/2024 Smith, Kyle 47 Trench Backfill: Sanitary Sewer: From the center water tank 2, ¶North.12.0 Inches below finish grade. Troxler / 3440 / 18792 / 01/24/2024 Smith, Kyle Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 43, 44, 45, 47: Informed Dylan with Jerome Bowen Construction verbally of all results, emailed all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 43 04/04/24 23-7428 C SM 8.6 124.6 5.4 122.5 129.1 10 98 95 DP 44 04/04/24 23-7428 C SM 8.6 124.6 3.4 122.2 126.4 10 98 95 DP 45 04/04/24 23-7428 C SM 8.6 124.6 4.6 122.2 127.8 10 98 95 DP 47 04/04/24 23-7428 C SM 8.6 124.6 3.4 121.7 125.8 10 98 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 04/07/2024 Report #: -00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 48 Trench Backfill: Sanitary Sewer: Backfill for pressured sewer shut off valve. East side of second East Road. First test ¶West and ¶South of shut off valve. 5.0 Feet below finished grade. Troxler / 3430 / 27237 / 01/23/2024 Rowley, Daniel 49 Trench Backfill: Sanitary Sewer: Backfill for pressured sewer shut off valve. East side of second East Road. ¶North of test 48. 5.0 Feet below finished grade. Troxler / 3430 / 27237 / 01/23/2024 Rowley, Daniel 50 Trench Backfill: Sanitary Sewer: Backfill for pressured sewer shut off valve. East side of second East Road. ¶South of test 49. 4.0 Feet below finished grade. Troxler / 3430 / 27237 / 01/23/2024 Rowley, Daniel 51 Trench Backfill: Sanitary Sewer: Backfill for pressured sewer shut off valve. East side of second East Road. ¶North of test 50 4.0 Feet below finished grade. Troxler / 3430 / 27237 / 01/23/2024 Rowley, Daniel Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 48, 49, 50, 51: Atlas Rep informed Dylan with Jerome Bowen of test results. Emailed to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 48 04/19/24 23-7428 C SM 8.6 124.6 4.1 120.0 124.9 8 96 95 DP 49 04/19/24 23-7428 C SM 8.6 124.6 4.1 119.7 124.6 8 96 95 DP 50 04/19/24 23-7428 C SM 8.6 124.6 4.1 118.4 123.3 8 95 95 DP 51 04/19/24 23-7428 C SM 8.6 124.6 3.6 123.6 128.1 8 99 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 04/19/2024 Report #: -01 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Reviewed and Approved by: Troy Posio Project Manager 04/19/2024 Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 52 Other, See Location Details: Northwest corner of tank at lift station # 1, 1 ft north and 3 ft east. 0.0 Top of base InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 53 Other, See Location Details: Northeast corner of building 12 ft north and 38 ft west.0.0 Top of base InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 54 Other, See Location Details: Northwest corner of building 7 ft north and 15 ft east.0.0 Top of base InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 52, 53, 54: Dylan with Jerome Bowen as notified of inspection results. Email sent to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 52 05/01/24 23-7428 C SM 8.6 124.6 6.0 119.1 126.2 4 96 0 DP 53 05/01/24 23-7428 C SM 8.6 124.6 4.3 129.2 134.7 4 104 0 DP 54 05/01/24 23-7428 C SM 8.6 124.6 3.5 118.7 122.9 4 95 0 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 05/01/2024 Report #: SNG-000001-00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 52 Other, See Location Details: Northwest corner of tank at lift station # 1, 1 ft north and 3 ft east. 0.0 Top of base InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 53 Other, See Location Details: Northeast corner of building 12 ft north and 38 ft west.0.0 Top of base InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 54 Other, See Location Details: Northwest corner of building 7 ft north and 15 ft east.0.0 Top of base InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 55 Other, See Location Details: Trash tank west side of building, from southwest corner of tank 2 ft west and 3 ft south. 3.0 Feet below base InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 52 05/01/24 23-7428 C SM 8.6 124.6 6.0 119.1 126.2 4 96 95 DP 53 05/01/24 23-7428 C SM 8.6 124.6 4.3 129.2 134.7 4 104 95 DP 54 05/01/24 23-7428 C SM 8.6 124.6 3.5 118.7 122.9 4 95 95 DP 55 05/01/24 23-7428 C SM 8.6 124.6 4.6 127.1 132.9 4 102 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 05/02/2024 Report #: SNG-000002-01 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Reviewed and Approved by: Troy Posio Project Manager 05/02/2024 Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 52 Other, See Location Details: Northwest corner of tank at lift station # 1, 1 ft north and 3 ft east. 0.0 Top of base InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 53 Other, See Location Details: Northeast corner of building 12 ft north and 38 ft west.0.0 Top of base InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 54 Other, See Location Details: Northwest corner of building 7 ft north and 15 ft east.0.0 Top of base InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian 55 Other, See Location Details: Trash tank west side of building, from southwest corner of tank 2 ft west and 3 ft south. 3.0 Feet below base InstroTex / 3500 / 5148 / 01/31/2024 Patterson, Julian Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 52, 53, 54, 55: Dylan with Jerome Bowen as notified of inspection results. Email sent to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 52 05/01/24 23-7428 C SM 8.6 124.6 6.0 119.1 126.2 4 96 0 DP 53 05/01/24 23-7428 C SM 8.6 124.6 4.3 129.2 134.7 4 104 0 DP 54 05/01/24 23-7428 C SM 8.6 124.6 3.5 118.7 122.9 4 95 0 DP 55 05/01/24 23-7428 C SM 8.6 124.6 4.6 127.1 132.9 4 102 0 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Revise report Test Method: ASTM D 6938 Report Date: 05/01/2024 Report #: SNG-000002-00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 56 Trench Backfill: Sanitary Sewer: 27ft S of sanitation sewer #1 7.5 Feet below finshed grade InstroTex / 3500 / 4555 / 01/09/2024 Mathie, Caysen 57 Trench Backfill: Sanitary Sewer: 6ft W of overflow box 1.0 Foot below finshed grade InstroTex / 3500 / 4555 / 01/09/2024 Mathie, Caysen Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 56, 57: Atlas rep notified Dylan with Jerome Bowen of test results. Email sent to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 56 05/06/24 23-7428 C SM 8.6 124.6 9.5 120.8 132.3 8 97 95 DP 57 05/06/24 23-7428 C SM 8.6 124.6 9.4 121.1 132.5 8 97 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 05/06/2024 Report #: SNG-000003-00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 56 Trench Backfill: Sanitary Sewer: 27ft S of sanitation sewer #1 7.5 Feet below finshed grade InstroTex / 3500 / 4555 / 01/09/2024 Mathie, Caysen 57 Trench Backfill: Sanitary Sewer: 6ft W of overflow box 1.0 Foot below finshed grade InstroTex / 3500 / 4555 / 01/09/2024 Mathie, Caysen Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 56, 57: Atlas rep notified Dylan with Jerome Bowen of test results. Email sent to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 56 05/06/24 23-7428 C SM 8.6 124.6 9.5 120.8 132.3 8 97 95 DP 57 05/06/24 23-7428 C SM 8.6 124.6 9.4 121.1 132.5 8 97 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 05/06/2024 Report #: SNG-000003-01 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Reviewed and Approved by: Troy Posio Project Manager 05/06/2024 Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 58 Trench Backfill: Irrigation: STA: 00+65, ¶LT of irrigation pipe.1.0 Feet under top of pipe.InstroTex / 3500 / 4555 / 01/09/2024 Franson, John 59 Trench Backfill: Irrigation: STA: 00+70, ¶LT of irrigation pipe.0.0 Feet under top of pipe.InstroTex / 3500 / 4555 / 01/09/2024 Franson, John 60 Trench Backfill: Irrigation: STA: 01+80, ¶LT of irrigation pipe.2.0 Feet above top of pipe.InstroTex / 3500 / 4555 / 01/09/2024 Franson, John 61 Structural Fill: Exterior Slab-on-Grade: Northern most NE corner of building: ¶N, ¶W. 8.0 Inches below top of concrete. InstroTex / 3500 / 4555 / 01/09/2024 Franson, John 62 Structural Fill: Exterior Slab-on-Grade: Northern most NE corner of building: ¶N, ¶W. 8.0 Inches below top of concrete. InstroTex / 3500 / 4555 / 01/09/2024 Franson, John 63 Trench Backfill: Irrigation: STA: 02+25, ¶LT of irrigation pipe.0.0 Feet above top of pipe.InstroTex / 3500 / 4555 / 01/09/2024 Franson, John Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 58, 59, 60: Southern most irrigation box=00+00. Rep informed Dillon of test results. Emailed to all approved recipients. 61, 62: Rep informed Dillon of test results. Emailed to all approved recipients. 63: Southern most irrigation box=00+00. Rep informed Dillon of test results. Emailed to all approved recipients. Sample taken from under gauge for a proctor. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 58 05/23/24 23-7428 D1557 C SM 8.6 124.6 6.6 124.2 132.4 8 100 95 DP 59 05/23/24 23-7428 D1557 C SM 8.6 124.6 6.7 126.1 134.5 8 101 95 DP 60 05/23/24 23-7428 D1557 C SM 8.6 124.6 6.9 126.2 134.9 8 101 95 DP 61 05/23/24 23-7428 D1557 C SM 8.6 124.6 4.0 121.2 126.0 8 97 95 DP 62 05/23/24 23-7428 D1557 C SM 8.6 124.6 4.7 118.1 123.6 8 95 95 DP 63 05/23/24 PENDING 9.0 110.1 120.0 8 95 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 05/24/2024 Report #: SNG-000004-00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 64 Trench Backfill: Waterline (exterior): Hydrate 81886-LM: ¶N, ¶W.2.0 Feet below finish grade.InstroTex / 3500 / 4555 / 01/09/2024 Franson, John 65 Trench Backfill: Waterline (exterior): Hydrate 81886-LM: ¶N, ¶W.2.0 Feet below finish grade.InstroTex / 3500 / 4555 / 01/09/2024 Franson, John 66 Asphalt: Parking Lot: NW corner of building: ¶N, ¶E.8.0 Inches below top of asphalt. InstroTex / 3500 / 4555 / 01/09/2024 Franson, John 67 Asphalt: Parking Lot: NW corner of building: ¶N, ¶E.8.0 Inches below top of asphalt. InstroTex / 3500 / 4555 / 01/09/2024 Franson, John 68 Asphalt: Parking Lot: NW corner of building: ¶N, ¶E.8.0 Inches below top of asphalt. InstroTex / 3500 / 4555 / 01/09/2024 Franson, John 69 Asphalt: Parking Lot: NW corner of building: ¶N, ¶E.8.0 Inches below top of asphalt. InstroTex / 3500 / 4555 / 01/09/2024 Franson, John Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 64, 65, 66, 67, 68, 69: Atlas Rep informed Dillon of test results. Emailed to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 64 06/06/24 23-7428 D1557 C SM 8.6 124.6 3.6 128.9 133.6 8 103 95 DP 65 06/06/24 23-7428 D1557 C SM 8.6 124.6 3.7 128.5 133.3 8 103 95 DP 66 06/06/24 23-7428 D1557 C SM 8.6 124.6 2.5 128.5 131.7 8 103 95 DP 67 06/06/24 23-7428 D1557 C SM 8.6 124.6 3.2 132.6 136.9 8 106 95 DP 68 06/06/24 23-7428 D1557 C SM 8.6 124.6 5.1 128.2 134.7 8 103 95 DP 69 06/06/24 23-7428 D1557 C SM 8.6 124.6 4.3 124.6 129.9 8 100 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 06/10/2024 Report #: SNG-000005-01 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Reviewed and Approved by: Troy Posio Project Manager 06/10/2024 Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 64 Trench Backfill: Waterline (exterior): Hydrate 81886-LM: ¶N, ¶W.2.0 Feet below finish grade.InstroTex / 3500 / 4555 / 01/09/2024 Franson, John 65 Trench Backfill: Waterline (exterior): Hydrate 81886-LM: ¶N, ¶W.2.0 Feet below finish grade.InstroTex / 3500 / 4555 / 01/09/2024 Franson, John 66 Asphalt: Parking Lot: NW corner of building: ¶N, ¶E.8.0 Inches below top of asphalt. InstroTex / 3500 / 4555 / 01/09/2024 Franson, John 67 Asphalt: Parking Lot: NW corner of building: ¶N, ¶E.8.0 Inches below top of asphalt. InstroTex / 3500 / 4555 / 01/09/2024 Franson, John 68 Asphalt: Parking Lot: NW corner of building: ¶N, ¶E.8.0 Inches below top of asphalt. InstroTex / 3500 / 4555 / 01/09/2024 Franson, John 69 Asphalt: Parking Lot: NW corner of building: ¶N, ¶E.8.0 Inches below top of asphalt. InstroTex / 3500 / 4555 / 01/09/2024 Franson, John Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 64, 65, 66, 67, 68, 69: Atlas Rep informed Dillon of test results. Emailed to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 64 06/06/24 23-7428 D1557 C SM 8.6 124.6 3.6 128.9 133.6 8 103 95 DP 65 06/06/24 23-7428 D1557 C SM 8.6 124.6 3.7 128.5 133.3 8 103 95 DP 66 06/06/24 23-7428 D1557 C SM 8.6 124.6 2.5 128.5 131.7 8 103 95 DP 67 06/06/24 23-7428 D1557 C SM 8.6 124.6 3.2 132.6 136.9 8 106 95 DP 68 06/06/24 23-7428 D1557 C SM 8.6 124.6 5.1 128.2 134.7 8 103 95 DP 69 06/06/24 23-7428 D1557 C SM 8.6 124.6 4.3 124.6 129.9 8 100 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 06/06/2024 Report #: SNG-000005-00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 70 Base Course: Concrete Paving: Car wash garage door main entrance SE corner, 40FT E 7FT S 6.0 Inches below finshed grade InstroTex / 3500 / 4555 / 01/09/2024 Mathie, Caysen 71 Base Course: Concrete Paving: E main entrance of main road 42FT W 18FT N 6.0 Inches below finshed grade InstroTex / 3500 / 4555 / 01/09/2024 Mathie, Caysen 72 Base Course: Concrete Paving: E main entrance of main road 42FT W 78FT N 6.0 Inches below finshed grade InstroTex / 3500 / 4555 / 01/09/2024 Mathie, Caysen 73 Base Course: Concrete Paving: NE corner of garage door car wash entrance 24FT N 1FT W. 6.0 Inches below finshed grade InstroTex / 3500 / 4555 / 01/09/2024 Mathie, Caysen 74 Base Course: Concrete Paving: Nw corner of service counter building 10FT W 58FT S. 6.0 Inches below finshed grade InstroTex / 3500 / 4555 / 01/09/2024 Mathie, Caysen Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 70, 71, 72, 73, 74: Atlas rep informed Jaden of test results. Email sent to all approved recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 70 06/11/24 23-7428 D1557 C SM 8.6 124.6 5.5 125.2 132.1 6 100 95 DP 71 06/11/24 23-7428 D1557 C SM 8.6 124.6 4.5 120.9 126.3 6 97 95 DP 72 06/11/24 23-7428 D1557 C SM 8.6 124.6 5.7 123.7 130.8 6 99 95 DP 73 06/11/24 23-7428 D1557 C SM 8.6 124.6 3.2 126.5 130.6 6 102 95 DP 74 06/11/24 23-7428 D1557 C SM 8.6 124.6 4.3 126.5 131.9 6 102 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 06/18/2024 Report #: SNG-000006-00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Reviewed and Approved by: Troy Posio Project Manager 06/18/2024 Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 75 Sub-base Fill: Pavement (asphalt): ¶feet North of fire hydrant on west side of job site this position will serve as station 00+00 running East. Station 00+15. 0.0 Below base.InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 76 Sub-base Fill: Pavement (asphalt): ¶feet North of fire hydrant on west side of job site this position will serve as station 00+00 running East. Station 00+36 ¶North of centerline. 0.0 Below base.InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 77 Sub-base Fill: Pavement (asphalt): ¶feet North of fire hydrant on west side of job site this position will serve as station 00+00 running East. Station 00+52 ¶North of centerline. 0.0 Below base.InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 78 Sub-base Fill: Pavement (asphalt): ¶feet North of fire hydrant on west side of job site this position will serve as station 00+00 running East. Station 01+05 2 South of centerline. 0.0 Below base.InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 79 Sub-base Fill: Pavement (asphalt): Eastbound lane of Moody road station from C.5.2 plans and specs. 55+25 1¶South of centerline. 0.0 Below base.InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 80 Sub-base Fill: Pavement (asphalt): Eastbound lane of Moody road station from C.5.2 plans and specs. 56+05 2¶South of centerline. 0.0 Below base.InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 81 Sub-base Fill: Pavement (asphalt): Eastbound lane of Moody road station from C.5.2 plans and specs. 56+34 2¶North of centerline. 0.0 Below base.InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 82 Sub-base Fill: Pavement (asphalt): Eastbound lane of Moody road station from C.5.2 plans and specs. 56+64 1¶North of centerline. 0.0 Below base.InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 75 06/20/24 CP 22-59 D698 C GP 4.9 135.7 3.6 133.0 137.8 4 98 95 DP 76 06/20/24 CP 22-59 D698 C GP 4.9 135.7 3.8 130.2 135.1 4 96 95 DP 77 06/20/24 CP 22-59 D698 C GP 4.9 135.7 3.4 132.3 136.8 4 97 95 DP 78 06/20/24 CP 22-59 D698 C GP 4.9 135.7 3.3 130.7 135.0 4 96 95 DP 79 06/20/24 CP 22-59 D698 C GP 4.9 135.7 2.0 128.9 131.5 4 95 95 DP 80 06/20/24 CP 22-59 D698 C GP 4.9 135.7 5.5 130.0 137.2 4 96 95 DP 81 06/20/24 CP 22-59 D698 C GP 4.9 135.7 5.3 130.9 137.9 4 96 95 DP 82 06/20/24 CP 22-59 D698 C GP 4.9 135.7 5.5 130.0 137.1 4 96 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 3 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 06/20/2024 Report #: SNG-000007-00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 75, 76, 77, 78, 79, 80, 81, 82: Informed Jeno with Jerome Bowen of all results. Email will be sent to all authorized recipients. These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 2 of 3 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 06/20/2024 Report #: SNG-000007-00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 83 Sub-base Fill: Pavement (asphalt): Eastbound lane of Moody road station from C.5.2 plans and specs. 57+00 3¶North of centerline. 0.0 Below base.InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 84 Sub-base Fill: Pavement (asphalt): Eastbound lane of Moody road station from C.5.2 plans and specs. 57+45 2¶North of centerline. 0.0 Below base.InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 85 Sub-base Fill: Pavement (asphalt): Eastbound lane of Moody road station from C.5.2 plans and specs. 57+86 2¶South of centerline. 0.0 Below base.InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 86 Sub-base Fill: Pavement (asphalt): ¶East of fire hydrant on West side of job site this position will serve as station 04+00 running South. 04+20 ¶East of centerline. 0.0 Below base.InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 87 Sub-base Fill: Pavement (asphalt): ¶East of fire hydrant on West side of job site this position will serve as station 04+00 running South. 04+50 ¶East of centerline. 0.0 Below base.InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 88 Sub-base Fill: Pavement (asphalt): ¶East of fire hydrant on West side of job site this position will serve as station 04+00 running South. 04+76 ¶East of centerline. 0.0 Below base.InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 83, 84, 85, 86, 87, 88: Informed Jeno with Jerome Bowen of all results. Email will be sent to all authorized recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 83 06/20/24 CP 22-59 D698 C GP 4.9 135.7 4.6 131.8 137.9 4 97 95 DP 84 06/20/24 CP 22-59 D698 C GP 4.9 135.7 3.2 129.1 133.2 4 95 95 DP 85 06/20/24 CP 22-59 D698 C GP 4.9 135.7 5.7 129.2 136.5 4 95 95 DP 86 06/20/24 CP 22-59 D698 C GP 4.9 135.7 6.2 130.0 138.0 4 96 95 DP 87 06/20/24 CP 22-59 D698 C GP 4.9 135.7 4.6 134.3 140.5 4 99 95 DP 88 06/20/24 CP 22-59 D698 C GP 4.9 135.7 3.2 135.8 140.2 4 100 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 3 of 3 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 06/20/2024 Report #: SNG-000007-00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 89 Base Course: Sidewalk: Sub base for sidewalk along Northside of Tagg n go building. 3¶North from Northeast corner of building this position will serve as station 00+00 running East. Station 00+06 1¶right of center. 0.0 Feet below sub base InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 90 Base Course: Sidewalk: Sub base for sidewalk along Northside of Tagg n go building. 3¶North from Northeast corner of building this position will serve as station 00+00 running East. Station 00+35 1¶left of center. 0.0 Feet below sub base InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 91 Base Course: Sidewalk: Sub base for sidewalk along Northside of Tagg n go building. 3¶North from Northeast corner of building this position will serve as station 00+00 running East. Station 00+63 2¶left of center. 0.0 Feet below sub base InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 92 Base Course: Sidewalk: Sub base for sidewalk along Northside of Tagg n go building. 3¶North from Northeast corner of building this position will serve as station 00+00 running East. Station 00+95 2¶right of center. 0.0 Feet below sub base InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian 93 Base Course: Sidewalk: Sub base for sidewalk along Northside of Tagg n go building. 3¶North from Northeast corner of building this position will serve as station 00+00 running East. Station 01+24 1¶right of center. 0.0 Feet below sub base InstroTex / 3500 / 4555 / 01/09/2024 Patterson, Julian Remarks DP: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 89, 90, 91, 92, 93: Atlas representative informed Gino with Jerome Bowen Construction of testing results. Email will be sent to all authorized recipients. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 89 07/31/24 23-7428 D1557 C SM 8.6 124.6 1.4 118.1 119.8 Backsca tter 95 95 DP 90 07/31/24 23-7428 D1557 C SM 8.6 124.6 1.3 120.8 122.4 Backsca tter 97 95 DP 91 07/31/24 23-7428 D1557 C SM 8.6 124.6 1.7 118.7 120.7 Backsca tter 95 95 DP 92 07/31/24 23-7428 D1557 C SM 8.6 124.6 2.1 119.3 121.8 Backsca tter 96 95 DP 93 07/31/24 23-7428 D1557 C SM 8.6 124.6 2.1 119.3 121.8 Backsca tter 96 95 DP These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client-approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 1 Soil Nuclear Gauge Test Method: ASTM D 6938 Report Date: 07/31/2024 Report #: SNG-000008-00 Client: CkQ Rexburg 2, LLC ST. George, UT 84791 PO Box 911839 Project: Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID E232004c Rexburg, ID 83440 1365 NORTH 2ND EAST 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Atlas Technical Consultants, LLC - Idaho Falls