HomeMy WebLinkAboutMETHOD SPECIFICATIONS - 23-00669 - Tagg N Go - Car WashInspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 02/21/2024 Jerome Brown Construction Lake, Noah Cloudy 39 NA Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Zaxis 210LC B­6 12psi pressure plate 0 NA Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 From SS 20 on center line 19’S 18 feet below finish grade Native 16 9 NA Yes 2 From SS 20 on center line 19’S 16feet and 6inches below finish grade Native 16 9 NA Yes 3 From SS 20 on center line 19’S 15 feet below finish grade Native 16 9 NA Yes 4 From SS 20 on center line 19’S 13feet ad 6inches below finish grade Native 16 9 NA Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: Native material placde was not too granular to test but depth of trench made it unsafe to test with a gauge. Method of compaction was approved by Noah Lake with Atlas. All material appeared firm and unyielding. Noah lake informed Gene with Jerome Bowen Construction. Emailed report to all approved recipients. ✔ Method Specification ­01Report #: 02/22/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 2Page 1 of 1 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 02/21/2024 Jerome Brown Construction Lake, Noah Cloudy 39 NA Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Zaxis 210LC B­6 12psi pressure plate 0 NA Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 From SS 20 on center line 19’S 18 feet below finish grade Native 16 9 NA Yes 2 From SS 20 on center line 19’S 16feet and 6inches below finish grade Native 16 9 NA Yes 3 From SS 20 on center line 19’S 15 feet below finish grade Native 16 9 NA Yes 4 From SS 20 on center line 19’S 13feet ad 6inches below finish grade Native 16 9 NA Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: Native material place was not too granular to test but depth of trench made it unsafe to test with a gauge. Method of compaction was approved by Noah Lake with Atlas. All material appeared firm and unyielding. Noah lake informed Gene with Jerome Bowen Construction of in compliance method. Emailed report to all approved recipient's. ✔ Method Specification ­00Report #: 02/21/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 2Page 1 of 1 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 02/22/2024 Jerome Bowen Sanderson, James Cloudy 34 Not provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Zaxis 210LC B­6 More than 12 psi 0 0 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 West sewer line from 35’ S. of stub to 15’ S. of stub 15’ below grade 2” minus native 12 4 N/A Yes 2 West sewer line from 35’ S. of stub to 15’ S. of stub 14’ below grade 2” minus native 12 4 N/A Yes 3 West sewer line from 35’ S. of stub to 15’ S. of stub 13’ below grade 2” minus native 12 4 N/A Yes 4 West sewer line from 35’ S. of stub to 10’ S. of T 12’ below grade 2” minus native 12 4 N/A Yes 5 West sewer line from 35’ S. of stub to T 11’ below grade 2” minus native 12 4 N/A Yes 6 West sewer line from stub to 15’ N. of T 10’ below grade 2” minus native 12 4 N/A Yes 7 West sewer line from stub to 60’ S. of stub 9’ below grade 2” minus native 12 4 N/A Yes 8 West sewer line from stub to 40’ S. of stub 8’ below grade 2” minus native 12 4 N/A Yes Method Specification ­01Report #: 02/22/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 3Page 1 of 2 Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number02/22/2024 Jerome Bowen Sanderson, James Cloudy 34 Not providedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Zaxis 210LC B­6 More than 12 psi 0 0Method Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance1West sewerline from 35’S. of stub to15’ S. of stub 15’ belowgrade 2” minusnative 12 4 N/A Yes2West sewerline from 35’S. of stub to15’ S. of stub 14’ belowgrade 2” minusnative 12 4 N/A Yes3West sewerline from 35’S. of stub to15’ S. of stub 13’ belowgrade 2” minusnative 12 4 N/A Yes4West sewerline from 35’S. of stub to10’ S. of T 12’ belowgrade 2” minusnative 12 4 N/A Yes5West sewerline from 35’S. of stub to T 11’ belowgrade 2” minusnative 12 4 N/A Yes6West sewer line from stub to 15’ N. of T 10’ below grade 2” minus native 12 4 N/A Yes 7 West sewer line from stub to 60’ S. of stub 9’ below grade 2” minus native 12 4 N/A Yes 8 West sewer line from stub to 40’ S. of stub 8’ below grade 2” minus native 12 4 N/A Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: Material has a proctor, but for safety reasons method spec was used. Method specification was followed in general accordance with ISPWC Sec. 306. Gene with Jerome Bowen informed on site of results. Report sent to all authorized recipients. Photo Documentation Below Sewer trench by roadway at 8’ below grade Sewer trench being excavated using a trench box ✔ Method Specification ­01Report #: 02/22/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 2 of 3Page 2 of 2 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 02/22/2024 Jerome Bowen Sanderson, James Cloudy 34 Not provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Hoe Pack More than 12 psi 0 0 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 West sewer line from 35’ S. of stub to 15’ S. of stub 15’ below grade 2” minus native 12 4 N/A Yes 2 West sewer line from 35’ S. of stub to 15’ S. of stub 14’ below grade 2” minus native 12 4 N/A Yes 3 West sewer line from 35’ S. of stub to 15’ S. of stub 13’ below grade 2” minus native 12 4 N/A Yes 4 West sewer line from 35’ S. of stub to 10’ S. of T 12’ below grade 2” minus native 12 4 N/A Yes 5 West sewer line from 35’ S. of stub to T 11’ below grade 2” minus native 12 4 N/A Yes 6 West sewer line from stub to 15’ N. of T 10’ below grade 2” minus native 12 4 N/A Yes 7 West sewer line from stub to 60’ S. of stub 9’ below grade 2” minus native 12 4 N/A Yes 8 West sewer line from stub to 40’ S. of stub 8’ below grade 2” minus native 12 4 N/A Yes Method Specification ­00Report #: 02/22/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 3Page 1 of 2 Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number02/22/2024 Jerome Bowen Sanderson, James Cloudy 34 Not providedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Hoe Pack More than 12 psi 0 0Method Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance1West sewerline from 35’S. of stub to15’ S. of stub 15’ belowgrade 2” minusnative 12 4 N/A Yes2West sewerline from 35’S. of stub to15’ S. of stub 14’ belowgrade 2” minusnative 12 4 N/A Yes3West sewerline from 35’S. of stub to15’ S. of stub 13’ belowgrade 2” minusnative 12 4 N/A Yes4West sewerline from 35’S. of stub to10’ S. of T 12’ belowgrade 2” minusnative 12 4 N/A Yes5West sewerline from 35’S. of stub to T 11’ belowgrade 2” minusnative 12 4 N/A Yes6West sewer line from stub to 15’ N. of T 10’ below grade 2” minus native 12 4 N/A Yes 7 West sewer line from stub to 60’ S. of stub 9’ below grade 2” minus native 12 4 N/A Yes 8 West sewer line from stub to 40’ S. of stub 8’ below grade 2” minus native 12 4 N/A Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: Material has a proctor, but for safety reasons method spec was used. Gene with Jerome Bowen informed on site of results. Report sent to all authorized recipients. Photo Documentation Below Sewer trench by roadway at 8’ below grade Sewer trench being excavated using a trench box ✔ Method Specification ­00Report #: 02/22/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 2 of 3Page 2 of 2 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 02/23/2024 Jerome Bowen Smith, Kyle Sunny 45 Not Provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Volvo SD75B 31,248 lbs / 1850 VPM 2 1.5 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 From the entrance on Moody Rd. Heading east approximately 150’. 90” below finish grade. Native material 18 7 Na Yes 2 From the entrance on Moody Rd. Heading east approximately 150’. 72” below finish grade. Native material 18 7 Na Yes 3 From the entrance on Moody Rd. Heading east approximately 150’. 54” below finish grade. Native material 18 7 Na Yes 4 From the entrance on Moody Rd. Heading east approximately 150’. 36” below finish grade. Native material 18 7 Na Yes 5 From the entrance on Moody Rd. Heading east approximately 150’. 18” below finish grade. Native material 18 7 Na Yes Method Specification ­01Report #: 02/27/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 3Page 1 of 2 Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number02/23/2024 Jerome Bowen Smith, Kyle Sunny 45 Not ProvidedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Volvo SD75B 31,248 lbs / 1850 VPM 2 1.5Method Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance1From theentrance onMoody Rd.Heading eastapproximately150’.90” belowfinish grade.Nativematerial 18 7 Na Yes2From theentrance onMoody Rd.Heading eastapproximately150’.72” belowfinish grade.Nativematerial 18 7 Na Yes3From theentrance onMoody Rd.Heading eastapproximately150’.54” belowfinish grade.Nativematerial 18 7 Na Yes4From the entrance on Moody Rd. Heading east approximately 150’. 36” below finish grade. Native material 18 7 Na Yes 5 From the entrance on Moody Rd. Heading east approximately 150’. 18” below finish grade. Native material 18 7 Na Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: Informed on­site representative for Jerome Bowen verbally of all results, emailed all approved recipients. Method Spec was used as it was unsafe to enter the area. Material placed appeared to be in a firm and Stable condition at the time of inspection. ✔ Method Specification ­01Report #: 02/27/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 2 of 3Page 2 of 2 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 02/23/2024 Jerome Bowen Smith, Kyle Sunny 45 Not Provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Volvo SD75B 31,248 Centrifuge Weight 2 1.5 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 From the entrance on Moody Rd. Heading east approximately 150’. 90” below finish grade. Native material 18 7 Na Yes 2 From the entrance on Moody Rd. Heading east approximately 150’. 72” below finish grade. Native material 18 7 Na Yes 3 From the entrance on Moody Rd. Heading east approximately 150’. 54” below finish grade. Native material 18 7 Na Yes 4 From the entrance on Moody Rd. Heading east approximately 150’. 36” below finish grade. Native material 18 7 Na Yes 5 From the entrance on Moody Rd. Heading east approximately 150’. 18” below finish grade. Native material 18 7 Na Yes Method Specification ­00Report #: 02/26/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 3Page 1 of 2 Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number02/23/2024 Jerome Bowen Smith, Kyle Sunny 45 Not ProvidedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Volvo SD75B 31,248 Centrifuge Weight 2 1.5Method Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance1From theentrance onMoody Rd.Heading eastapproximately150’.90” belowfinish grade.Nativematerial 18 7 Na Yes2From theentrance onMoody Rd.Heading eastapproximately150’.72” belowfinish grade.Nativematerial 18 7 Na Yes3From theentrance onMoody Rd.Heading eastapproximately150’.54” belowfinish grade.Nativematerial 18 7 Na Yes4From the entrance on Moody Rd. Heading east approximately 150’. 36” below finish grade. Native material 18 7 Na Yes 5 From the entrance on Moody Rd. Heading east approximately 150’. 18” below finish grade. Native material 18 7 Na Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes:Informed on­site representative for Jerome Bowen verbally of all results, emailed all approved recipients. ✔ Method Specification ­00Report #: 02/26/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 2 of 3Page 2 of 2 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 02/27/2024 Jerome Bowen Construction Rowley, Daniel Cloudy 19 Not Provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Kent 135 Greater than 12 PSI plate pressure. 0 0 Volvo SD75B 31,248 lbs / 1850 VBM 2 1.5 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 South of the Moody Rd. approach starting at 150' to 200'. 10' below finished grade. Native Material 12"7 N/A Yes 2 South of the Moody Rd. approach starting at 150' to 200'. 9' below finished grade. Native Material 12"7 N/A Yes 3 South of the Moody Rd. approach starting at 150' to 200'. 8' below finished grade. Native Material 12"7 N/A Yes 4 South of the Moody Rd. approach starting at 150' to 200'. 7' below finished grade. Native Material 12"7 N/A Yes 5 South of the Moody Rd. approach starting at 150' to 200'. 6' below finished grade. Native Material 12"12 N/A Yes Method Specification ­01Report #: 03/01/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 3Page 1 of 2 Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number02/27/2024 Jerome BowenConstruction Rowley, Daniel Cloudy 19 Not ProvidedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Kent 135 Greater than 12 PSI platepressure.0 0Volvo SD75B 31,248 lbs / 1850 VBM 2 1.5Method Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance1South of theMoody Rd.approachstarting at150' to 200'.10' belowfinishedgrade.NativeMaterial 12"7 N/A Yes2South of theMoody Rd.approachstarting at150' to 200'.9' belowfinishedgrade.NativeMaterial 12"7 N/A Yes3South of the Moody Rd. approach starting at 150' to 200'. 8' below finished grade. Native Material 12"7 N/A Yes 4 South of the Moody Rd. approach starting at 150' to 200'. 7' below finished grade. Native Material 12"7 N/A Yes 5 South of the Moody Rd. approach starting at 150' to 200'. 6' below finished grade. Native Material 12"12 N/A Yes 6 South of the Moody Rd. approach starting at 150' to 200'. 5' below finished grade. Native Material 12"12 N/A Yes 7 South of the Moody Rd. approach starting at 150' to 180'. 4' below finished grade. Native Material 12"12 N/A Yes 8 South of the Moody Rd. approach starting at 150' to 180'. 3' below finished grade. Native Material 12"12 N/A Yes 9 South of the Moody Rd. approach starting at 150' to 180'. 2' below finished grade. Native Material 12"12 N/A Yes 10 South of the Moody Rd. approach starting at 150' to 180'. 1' below finished grade. Native Material 12"12 N/A Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: Tests 1 to 4 were performed by hoe pack (see equipment 1). Native material place was not too granular to test but depth of trench made it unsafe to test with a gauge. Tests 5 through 10 were performed by a roller (see equipment 2). Informed Jene with Jerome Bowen Construction of test results. Emailed all approved receipts. ✔ Method Specification ­01Report #: 03/01/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 2 of 3Page 2 of 2 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 02/27/2024 Jerome Bowen Construction Rowley, Daniel Cloudy 19 Not Provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Kent 135 13500 lbs / 2000 VBM 0 0 Volvo SD75B 31,248 lbs / 1850 VBM 2 1.5 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 Moody road entrance: 150' to 200' South 10' below finished grad. Native Material 12"7 N/A Yes 2 Moody road entrance: 150' to 200' South 9' below finished grad. Native Material 12"7 N/A Yes 3 Moody road entrance: 150' to 200' South 8' below finished grad. Native Material 12"7 N/A Yes 4 Moody road entrance: 150' to 200' South. 7' below finished grad. Native Material 12"7 N/A Yes 5 Moody road entrance: 150' to 200' South 6' below finished grad Native Material 12"12 N/A Yes 6 Moody road entrance: 150' to 200' South 5' below finished grad. Native Material 12"12 N/A Yes 7 Moody road entrance: 150' to 180' South 4' below finished grad. Native Material 12"12 N/A Yes 8 Moody road entrance: 150' to 180' South 3' below finished grad. Native Material 12"12 N/A Yes 1 Moody road entrance: 150' to 180' South 2' below finished grad. Native Material 12"12 N/A Yes Method Specification ­00Report #: 02/27/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 3Page 1 of 2 Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number02/27/2024 Jerome BowenConstruction Rowley, Daniel Cloudy 19 Not ProvidedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Kent 135 13500 lbs / 2000 VBM 0 0Volvo SD75B 31,248 lbs / 1850 VBM 2 1.5Method Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance1Moody roadentrance: 150'to 200' South 10' belowfinished grad.NativeMaterial 12"7 N/A Yes2Moody roadentrance: 150'to 200' South 9' belowfinished grad.NativeMaterial 12"7 N/A Yes3Moody roadentrance: 150'to 200' South 8' belowfinished grad.NativeMaterial 12"7 N/A Yes4Moody roadentrance: 150'to 200' South.7' belowfinished grad.NativeMaterial 12"7 N/A Yes5Moody roadentrance: 150'to 200' South 6' belowfinished grad NativeMaterial 12"12 N/A Yes 6 Moody road entrance: 150' to 200' South 5' below finished grad. Native Material 12"12 N/A Yes 7 Moody road entrance: 150' to 180' South 4' below finished grad. Native Material 12"12 N/A Yes 8 Moody road entrance: 150' to 180' South 3' below finished grad. Native Material 12"12 N/A Yes 1 Moody road entrance: 150' to 180' South 2' below finished grad. Native Material 12"12 N/A Yes 10 Moody road entrance: 150' to 180' South 1' below finished grad. Native Material 12"12 N/A Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: 30% retained on the 3/4" seive causing the material to granular to test. Informed Jene with Jerome Bowen Construction of test results. Emailed all approved receipts. ✔ Method Specification ­00Report #: 02/27/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 2 of 3Page 2 of 2 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 02/29/2024 Jerome bowen Lake, Noah Cloudy 35 Not provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Volvo SD 75B 31,248lbs/1850VBM 2 1.5 Zaxis 210LC B­6 12PSI plate pressure 0 0 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 From manhole to 102’S 11 feet below finish grade Native 12 9 NA Yes 2 From manhole to 102’S 10 feet below finish grade Native 12 12 NA Yes 3 From manhole to 102’S 9 feet below finish grade Native 12 12 NA Yes 4 From manhole to 102’S 8 feet below finish grade Native 12 12 NA Yes 5 From manhole to 102’S 7 feet below finish grade Native 12 12 NA Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: First test Zaxis 210LC B­6 was used in general accordance with ISPWC 306. Native material place was not too granular to test but depth of trench made it unsafe to test with a gauge. Method of compaction was approved by Troy Posio with Atlas. All material appeared firm and unyielding. Noah lake informed Gene with Jerome Bowen Construction of in compliance method. emailed report to all approved recipient's. ✔ Method Specification ­01Report #: 03/01/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 2Page 1 of 1 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 02/29/2024 Jerome bowen Lake, Noah Cloudy 35 Not provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Volvo SD 75B 31,248lbs/1850VBM 2 1.5 Zaxis 210LC B­6 12PSI plate pressure 0 0 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 From manhole to 102’S 11 feet below finish grade Native 12 9 NA Yes 2 From manhole to 102’S 10 feet below finish grade Native 12 12 NA Yes 3 From manhole to 102’S 9 feet below finish grade Native 12 12 NA Yes 4 From manhole to 102’S 8 feet below finish grade Native 12 12 NA Yes 5 From manhole to 102’S 7 feet below finish grade Native 12 12 NA Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: First test Zaxis 210LC B­6 was used. Native material place was not too granular to test but depth of trench made it unsafe to test with a gauge. Method of compaction was approved by Noah Lake with Atlas. All material appeared firm and unyielding. Noah lake informed Gene with Jerome Bowen Construction of in compliance method. emailed report to all approved recipient's. ✔ Method Specification ­00Report #: 02/29/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 2Page 1 of 1 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 02/28/2024 Jerome Bowen Construction Neibaur, Rick Windy 28 Not provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Hitachi 210LC­6 Exceeds 12 psi plate pressure 0 N/A Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 12 radius around man hole #2 16.5 feet below finished grade Native rocky/gravely sand 18”6 N/A Yes 2 12 radius around man hole #2 15 feet below finished grade Native rocky/gravely sand 18”6 N/A Yes 3 12 radius around man hole #2 13.5 feet below finished grade Native rocky/gravely sand 18”6 N/A Yes 4 12 radius around man hole #2 12 feet below finished grade Native rocky/gravely sand 18”6 N/A Yes 5 12 radius around man hole #2 10.5 feet below finished grade Native rocky/gravely sand 18”6 N/A Yes 6 12 radius around man hole #2 9 feet below finished grade Native rocky/gravely sand 18”6 N/A Yes 7 12 radius around man hole #2 7.5 feet below finished grade Native rocky/gravely sand 18”6 N/A Yes Method Specification ­00Report #: 03/01/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 3Page 1 of 2 Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number02/28/2024 Jerome BowenConstruction Neibaur, Rick Windy 28 Not providedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Hitachi 210LC­6 Exceeds 12 psi plate pressure 0 N/AMethod Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance112 radiusaround manhole #2 16.5 feetbelowfinishedgrade Nativerocky/gravelysand 18”6 N/A Yes212 radiusaround manhole #2 15 feet belowfinishedgrade Nativerocky/gravelysand 18”6 N/A Yes312 radiusaround manhole #2 13.5 feetbelowfinishedgrade Nativerocky/gravelysand 18”6 N/A Yes412 radiusaround manhole #2 12 feet belowfinishedgrade Nativerocky/gravelysand 18”6 N/A Yes 5 12 radius around man hole #2 10.5 feet below finished grade Native rocky/gravely sand 18”6 N/A Yes 6 12 radius around man hole #2 9 feet below finished grade Native rocky/gravely sand 18”6 N/A Yes 7 12 radius around man hole #2 7.5 feet below finished grade Native rocky/gravely sand 18”6 N/A Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: Method specification preformed in general accordance of ISPWC 306 where trench was filled and compacted using hoe pack. Native material place was not too granular to test but depth of trench made it unsafe to test with a gauge. Gene with JBC was notified of test results. Email sent to all approved recipients. ✔ Method Specification ­00Report #: 03/01/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 2 of 3Page 2 of 2 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 03/07/2024 Jerome bowen Patterson, Julian Cool 28 Not provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Kent khp135 More then 12 psi 0 O Volvo sd75 30000,lb 2025 vpm 2 2 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 T juction trench to future access 10 ft below grade Native 6 inches 6 Not provided Yes 2 T juction trench to future access 9 1/2 ft below grade Native 6 inches 6 Not provided Yes 3 T juction trench to future access 9 ft below grade Native 6 inches 6 Not provided Yes 4 T juction trench to future access 8 1/2 ft below grade Native 6 inches 6 Not provided Yes 5 T juction trench to future access 8 ft below grade Native 12 inches 6 Not provided Yes 6 T juction trench to future access 7 ft below grade Native 12 inches 6 Not provided Yes 7 T juction trench to future access 6 ft below grade Native 12 inches 6 Not provided Yes 8 T juction trench to future access 5 ft below grade Native 6 inches 6 Not provided Yes Method Specification ­00Report #: 03/07/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 1 of 3Page 1 of 2 Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number03/07/2024 Jerome bowen Patterson, Julian Cool 28 Not providedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Kent khp135 More then 12 psi 0 OVolvo sd75 30000,lb 2025 vpm 2 2Method Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance1T juctiontrench tofuture access 10 ft belowgrade Native 6 inches 6 Not provided Yes2T juctiontrench tofuture access 9 1/2 ft belowgrade Native 6 inches 6 Not provided Yes3T juctiontrench tofuture access 9 ft belowgrade Native 6 inches 6 Not provided Yes4T juctiontrench tofuture access 8 1/2 ft belowgrade Native 6 inches 6 Not provided Yes5T juctiontrench tofuture access 8 ft belowgrade Native 12 inches 6 Not provided Yes 6 T juction trench to future access 7 ft below grade Native 12 inches 6 Not provided Yes 7 T juction trench to future access 6 ft below grade Native 12 inches 6 Not provided Yes 8 T juction trench to future access 5 ft below grade Native 6 inches 6 Not provided Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: Tests 1­6 compacted in genral accordance to ISPWC 306 using a hoe pack. Tests 7­8 were compacted in with accordance ISPWC 202 using a vibratory roller. Dillon with Jerome Bowen was notified of results. Email will be sent to all authorized recipients. ✔ Method Specification ­00Report #: 03/07/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our company. Page 2 of 3Page 2 of 2 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 03/13/2024 Jerome Bowen Construction Adams, Dustin Cloudy 34 Not Provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Zaxis 210 LC 12 PSI Plate Pressure 0 N/A Volvo SD75 31248 lbs/1850 VBM 2 1.5 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 10’ West of SS Tee 1 to 105’ East of SS Tee 1 12’ Below Finish Grade Native Soil 12 9 N/A Yes 2 10’ West of SS Tee 1 to 105’ East of SS Tee 1 11’ Below Finish Grade Native Soil 12 12 N/A Yes 3 10’ West of SS Tee 1 to 105’ East of SS Tee 1 10’ Below Finish Grade Native Soil 12 12 N/A Yes 4 10’ West of SS Tee 1 to 105’ East of SS Tee 1 9’ Below Finish Grade Native Soil 12 12 N/A Yes 5 10’ West of SS Tee 1 to 105’ East of SS Tee 1 8’ Below Finish Grade Native Soil 12 12 N/A Yes 6 10’ West of SS Tee 1 to 105’ East of SS Tee 1 7’ Below Finish Grade Native Soil 12 12 N/A Yes 7 10’ West of SS Tee 1 to 105’ East of SS Tee 1 6’ Below Finish Grade Native Soil 12 12 N/A Yes Method Specification ­01Report #: 03/15/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 3Page 1 of 2 Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number03/13/2024 Jerome BowenConstruction Adams, Dustin Cloudy 34 Not ProvidedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Zaxis 210 LC 12 PSI Plate Pressure 0 N/AVolvo SD75 31248 lbs/1850 VBM 2 1.5Method Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance110’ West ofSS Tee 1 to105’ East ofSS Tee 1 12’ BelowFinish Grade Native Soil 12 9 N/A Yes210’ West ofSS Tee 1 to105’ East ofSS Tee 1 11’ BelowFinish Grade Native Soil 12 12 N/A Yes310’ West ofSS Tee 1 to105’ East ofSS Tee 1 10’ BelowFinish Grade Native Soil 12 12 N/A Yes410’ West ofSS Tee 1 to105’ East of SS Tee 1 9’ BelowFinish Grade Native Soil 12 12 N/A Yes 5 10’ West of SS Tee 1 to 105’ East of SS Tee 1 8’ Below Finish Grade Native Soil 12 12 N/A Yes 6 10’ West of SS Tee 1 to 105’ East of SS Tee 1 7’ Below Finish Grade Native Soil 12 12 N/A Yes 7 10’ West of SS Tee 1 to 105’ East of SS Tee 1 6’ Below Finish Grade Native Soil 12 12 N/A Yes 8 10’ West of SS Tee 1 to 105’ East of SS Tee 1 5’ Below Finish Grade Native Soil 12 12 N/A Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: First lift was compacted with Hoepack and was performed in general accordance with ISPWC Sec. 306 , Hoepack had malfunction so Roller was used for all tests proceeding No. 1 and were performed in accordance with ISPWC 202­3.8­C­3. Method spec. was used in place of nuclear gauge due to trench being too deep to safely be in. Atlas Rep. was accompanied by Braydon Peterson (Atlas). Atlas reps. informed Dillon with Jerome Bowen Construction of all inspection results. Email sent to all approved recipients. ✔ Method Specification ­01Report #: 03/15/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 2 of 3Page 2 of 2 Reviewed and Approved by: Troy Posio Project Manager 03/15/2024 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 03/13/2024 Jerome Bowen Construction Adams, Dustin Cloudy 34 Not Provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Zaxis 210 LC 12 PSI Plate Pressure 0 N/A Volvo SD75 31248 lbs/1850 VBM 2 1.5 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 10’ West of SS Tee 1 to 105’ East of SS Tee 1 12’ Below Finish Grade Native Soil 12 9 N/A Yes 2 10’ West of SS Tee 1 to 105’ East of SS Tee 1 11’ Below Finish Grade Native Soil 12 12 N/A Yes 3 10’ West of SS Tee 1 to 105’ East of SS Tee 1 10’ Below Finish Grade Native Soil 12 12 N/A Yes 4 10’ West of SS Tee 1 to 105’ East of SS Tee 1 9’ Below Finish Grade Native Soil 12 12 N/A Yes 5 10’ West of SS Tee 1 to 105’ East of SS Tee 1 8’ Below Finish Grade Native Soil 12 12 N/A Yes 6 10’ West of SS Tee 1 to 105’ East of SS Tee 1 7’ Below Finish Grade Native Soil 12 12 N/A Yes 7 10’ West of SS Tee 1 to 105’ East of SS Tee 1 6’ Below Finish Grade Native Soil 12 12 N/A Yes Method Specification ­00Report #: 03/13/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 3Page 1 of 2 Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number03/13/2024 Jerome BowenConstruction Adams, Dustin Cloudy 34 Not ProvidedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Zaxis 210 LC 12 PSI Plate Pressure 0 N/AVolvo SD75 31248 lbs/1850 VBM 2 1.5Method Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance110’ West ofSS Tee 1 to105’ East ofSS Tee 1 12’ BelowFinish Grade Native Soil 12 9 N/A Yes210’ West ofSS Tee 1 to105’ East ofSS Tee 1 11’ BelowFinish Grade Native Soil 12 12 N/A Yes310’ West ofSS Tee 1 to105’ East ofSS Tee 1 10’ BelowFinish Grade Native Soil 12 12 N/A Yes410’ West ofSS Tee 1 to105’ East of SS Tee 1 9’ BelowFinish Grade Native Soil 12 12 N/A Yes 5 10’ West of SS Tee 1 to 105’ East of SS Tee 1 8’ Below Finish Grade Native Soil 12 12 N/A Yes 6 10’ West of SS Tee 1 to 105’ East of SS Tee 1 7’ Below Finish Grade Native Soil 12 12 N/A Yes 7 10’ West of SS Tee 1 to 105’ East of SS Tee 1 6’ Below Finish Grade Native Soil 12 12 N/A Yes 8 10’ West of SS Tee 1 to 105’ East of SS Tee 1 5’ Below Finish Grade Native Soil 12 12 N/A Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: First lift was compacted with Hoepack and was performed in general accordance with ISPWC Sec. 6 , Hoepack had malfunction so Roller was used for all tests proceeding No. 1 and were performed in accordance with ISPWC 202­3.8­C­3. Atlas Rep. was accompanied by Braydon Peterson (Atlas). Atlas reps. informed Dillon with Jerome Bowen Construction of all inspection results. Email sent to all approved recipients. ✔ Method Specification ­00Report #: 03/13/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 2 of 3Page 2 of 2 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 03/14/2024 Jerome Bowen Construction Patterson, Julian Sunny 41 Not provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Volvo sd75 30000,lb 2025 vpm 2 2 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 From Manhole #2 to 40 feet south of manhole 5 ft below grade Native 12 12 Not provided Yes 2 From Manhole #2 to 40 feet south of manhole 4 ft below grade Native 12 12 Not provided Yes 3 From Manhole #2 to 40 feet south of manhole 3 ft below grade Native 12 12 Not provided Yes 4 From Manhole #2 to 40 feet south of manhole 2 ft below grade Native 12 12 Not provided Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: Lifts were compacted in with accordance ISPWC 202 using a vibratory roller. Test 1 densities were not performed due to safety concerns in the trench. Tests 2 and 3 have accompanying density shots, see density report dated today. Test 4 contractor requested no density testing. Dillon with Jerome Bowen was notified of results. Email will be sent to all authorized recipients. ✔ Method Specification ­01Report #: 03/15/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 2Page 1 of 1Page 1 of 2 Method Specification ­01Report #: 03/15/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 2 of 2Page 1 of 1Page 2 of 2 Reviewed and Approved by: Troy Posio Project Manager 03/15/2024 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 03/14/2024 Jerome Bowen Construction Patterson, Julian Sunny 41 Not provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Volvo sd75 30000,lb 2025 vpm 2 2 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 Along sewer trench S of manhole 2 5 ft below grade Native 12 6 Not provided Yes 2 Along sewer trench S of manhole 2 4 ft below grade Native 12 6 Not provided Yes 3 Along sewer trench S of manhole 2 3 ft below grade Native 12 6 Not provided Yes 4 Along sewer trench S of manhole 2 2 ft below grade Native 12 6 Not provided Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: Tests were compacted in with accordance ISPWC 202 using a vibratory roller. Dillon with Jerome Bowen was notified of results. Email will be sent to all authorized recipients. ✔ Method Specification ­00Report #: 03/14/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 2Page 1 of 1 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 03/20/2024 Jerome Bowen Construction Neibaur, Rick Sunny 55 Not provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Volvo ECR145EL Exceeds 12psi 0 N/A Wacker Neuson DPU5545 12,364.5 VPM 0 N/A Volvo SD115 58,050lbs / 2025 VPM 2 1.5 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 6’ Radius around Tank 3 5.5’ below top of vault Native pit run 12 15 N/A Yes 2 6’ Radius around tank 3 4.5’ below top of vault Native pit run 12 15 N/A Yes 3 6’ radius around Tank 3 3.5’ below top of tank Native pit run 12 15 N/A Yes 4 6’ radius around Tank 3 2.5’ below top of tank Native pit run 12 15 N/A Yes 5 6’ radius around Tank 3 1.5’ below top of tank Native pit run 12 15 N/A Yes 6 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 20” above buried plumbing pipe. Native pit run 16 6 N/A Yes 7 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 32” above buried plumbing pipe. Native pit run 12 6 N/A Yes Method Specification ­02Report #: 03/26/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 5Page 1 of 4 Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number03/20/2024 Jerome BowenConstruction Neibaur, Rick Sunny 55 Not providedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Volvo ECR145EL Exceeds 12psi 0 N/AWacker Neuson DPU5545 12,364.5 VPM 0 N/AVolvo SD115 58,050lbs / 2025 VPM 2 1.5Method Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance16’ Radiusaround Tank 3 5.5’ below topof vault Native pit run 12 15 N/A Yes26’ Radiusaround tank 3 4.5’ below topof vault Native pit run 12 15 N/A Yes36’ radiusaround Tank 3 3.5’ below topof tank Native pit run 12 15 N/A Yes46’ radiusaround Tank 3 2.5’ below topof tank Native pit run 12 15 N/A Yes 5 6’ radius around Tank 3 1.5’ below top of tank Native pit run 12 15 N/A Yes 6 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 20” above buried plumbing pipe. Native pit run 16 6 N/A Yes 7 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 32” above buried plumbing pipe. Native pit run 12 6 N/A Yes 8 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 44” above buried plumbing pipe. Native pit run 12 6 N/A Yes 9 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 56” above buried plumbing pipe. Native pit run 12 6 N/A Yes 10 35’ W of Tank 4 1’ below top of tank Native pit run 16 7 N/A Yes 11 35’ W of Tank 4 0” below top of tank Native pit run 12 7 N/A Yes 12 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 68” above buried plumbing pipe. Native pit run 12 6 N/A Yes 13 35’ W of Tank 4 1’ above top of tank Native pit run 12 7 N/A Yes 14 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 1’ above top of tank. Native pit run 12 7 N/A Yes 15 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 2’ above top of tank. Native pit run 12 7 N/A Yes 16 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 3’ above top of tank. Native pit run 12 7 N/A Yes 17 35’ W of Tank 4 2’ above top of tank Native pit run 12 7 N/A Yes 18 35’ W of Tank 4 3’ above top of tank Native pit run 12 7 N/A Yes Method Specification ­02Report #: 03/26/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 2 of 5Page 2 of 4 Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number03/20/2024 Jerome BowenConstruction Neibaur, Rick Sunny 55 Not providedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Volvo ECR145EL Exceeds 12psi 0 N/AWacker Neuson DPU5545 12,364.5 VPM 0 N/AVolvo SD115 58,050lbs / 2025 VPM 2 1.5Method Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance16’ Radiusaround Tank 3 5.5’ below topof vault Native pit run 12 15 N/A Yes26’ Radiusaround tank 3 4.5’ below topof vault Native pit run 12 15 N/A Yes36’ radiusaround Tank 3 3.5’ below topof tank Native pit run 12 15 N/A Yes46’ radiusaround Tank 3 2.5’ below topof tank Native pit run 12 15 N/A Yes56’ radiusaround Tank 3 1.5’ below topof tank Native pit run 12 15 N/A Yes6From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.20” aboveburiedplumbingpipe.Native pit run 16 6 N/A Yes7From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.32” aboveburiedplumbingpipe.Native pit run 12 6 N/A Yes8From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.44” aboveburiedplumbingpipe.Native pit run 12 6 N/A Yes9From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.56” aboveburiedplumbingpipe.Native pit run 12 6 N/A Yes1035’ W of Tank4 1’ below topof tank Native pit run 16 7 N/A Yes1135’ W of Tank4 0” below topof tank Native pit run 12 7 N/A Yes12From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.68” aboveburiedplumbingpipe.Native pit run 12 6 N/A Yes1335’ W of Tank4 1’ above topof tank Native pit run 12 7 N/A Yes14From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.1’ above topof tank.Native pit run 12 7 N/A Yes15From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.2’ above topof tank.Native pit run 12 7 N/A Yes 16 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 3’ above top of tank. Native pit run 12 7 N/A Yes 17 35’ W of Tank 4 2’ above top of tank Native pit run 12 7 N/A Yes 18 35’ W of Tank 4 3’ above top of tank Native pit run 12 7 N/A Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: Method specification performed in accordance with ISPWC section 306 and 202. It was discussed with Troy Posio, plate compactor being used for compaction was suitable for use. Plate compactor used for records 1­5, HOPAC used for records 6­9, 12, 14­16, and 18, and roller used for 10, 11, 13, and 17. Dylan with Jerome as notified of inspection results. Email sent to all approved recipients. Photo Documentation Below Area of backfill around Tank 3. HOPAC and Plate compactor used for compaction. Area of backfill S of Tank 4 E of Tank 3. HOPAC used for compaction. ✔ Method Specification ­02Report #: 03/26/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 3 of 5Page 3 of 4 Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number03/20/2024 Jerome BowenConstruction Neibaur, Rick Sunny 55 Not providedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Volvo ECR145EL Exceeds 12psi 0 N/AWacker Neuson DPU5545 12,364.5 VPM 0 N/AVolvo SD115 58,050lbs / 2025 VPM 2 1.5Method Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance16’ Radiusaround Tank 3 5.5’ below topof vault Native pit run 12 15 N/A Yes26’ Radiusaround tank 3 4.5’ below topof vault Native pit run 12 15 N/A Yes36’ radiusaround Tank 3 3.5’ below topof tank Native pit run 12 15 N/A Yes46’ radiusaround Tank 3 2.5’ below topof tank Native pit run 12 15 N/A Yes56’ radiusaround Tank 3 1.5’ below topof tank Native pit run 12 15 N/A Yes6From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.20” aboveburiedplumbingpipe.Native pit run 16 6 N/A Yes7From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.32” aboveburiedplumbingpipe.Native pit run 12 6 N/A Yes8From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.44” aboveburiedplumbingpipe.Native pit run 12 6 N/A Yes9From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.56” aboveburiedplumbingpipe.Native pit run 12 6 N/A Yes1035’ W of Tank4 1’ below topof tank Native pit run 16 7 N/A Yes1135’ W of Tank4 0” below topof tank Native pit run 12 7 N/A Yes12From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.68” aboveburiedplumbingpipe.Native pit run 12 6 N/A Yes1335’ W of Tank4 1’ above topof tank Native pit run 12 7 N/A Yes14From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.1’ above topof tank.Native pit run 12 7 N/A Yes15From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.2’ above topof tank.Native pit run 12 7 N/A Yes16From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.3’ above topof tank.Native pit run 12 7 N/A Yes1735’ W of Tank4 2’ above topof tank Native pit run 12 7 N/A Yes1835’ W of Tank4 3’ above topof tank Native pit run 12 7 N/A YesMaterial Tested per:ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section)Notes:Method specification performed in accordance with ISPWC section 306 and 202. It was discussed with Troy Posio, plate compactorbeing used for compaction was suitable for use. Plate compactor used for records 1­5, HOPAC used for records 6­9, 12, 14­16, and18, and roller used for 10, 11, 13, and 17. Dylan with Jerome as notified of inspection results. Email sent to all approved recipients.Photo Documentation Below Area of backfill around Tank 3. HOPAC and Plate compactor used for compaction. Area of backfill S of Tank 4 E of Tank 3. HOPAC used for compaction. Area of backfill S of Tank 4. Roller used for compaction. ✔ Method Specification ­02Report #: 03/26/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 4 of 5Page 4 of 4 Reviewed and Approved by: Troy Posio Project Manager 03/26/2024 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 03/20/2024 Jerome Bowen Construction Neibaur, Rick Sunny 55 Not provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Volvo ECR145EL Exceeds 12psi 0 N/A Wacker Neuson DPU5545 12,364.5 VPM 0 N/A Volvo SD115 58,050lbs / 2025 VPM 2 1.5 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 6’ Radius around Tank 3 5.5’ below top of vault Native pit run 12 15 N/A Yes 2 6’ Radius around tank 3 4.5’ below top of vault Native pit run 12 15 N/A Yes 3 6’ radius around Tank 3 3.5’ below top of tank Native pit run 12 15 N/A Yes 4 6’ radius around Tank 3 2.5’ below top of tank Native pit run 12 15 N/A Yes 5 6’ radius around Tank 3 1.5’ below top of tank Native pit run 12 15 N/A Yes 6 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 20” above buried plumbing pipe. Native pit run 16 6 N/A Yes 7 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 32” above buried plumbing pipe. Native pit run 12 6 N/A Yes Method Specification ­03Report #: 04/14/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 5Page 1 of 4 Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number03/20/2024 Jerome BowenConstruction Neibaur, Rick Sunny 55 Not providedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Volvo ECR145EL Exceeds 12psi 0 N/AWacker Neuson DPU5545 12,364.5 VPM 0 N/AVolvo SD115 58,050lbs / 2025 VPM 2 1.5Method Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance16’ Radiusaround Tank 3 5.5’ below topof vault Native pit run 12 15 N/A Yes26’ Radiusaround tank 3 4.5’ below topof vault Native pit run 12 15 N/A Yes36’ radiusaround Tank 3 3.5’ below topof tank Native pit run 12 15 N/A Yes46’ radiusaround Tank 3 2.5’ below topof tank Native pit run 12 15 N/A Yes 5 6’ radius around Tank 3 1.5’ below top of tank Native pit run 12 15 N/A Yes 6 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 20” above buried plumbing pipe. Native pit run 16 6 N/A Yes 7 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 32” above buried plumbing pipe. Native pit run 12 6 N/A Yes 8 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 44” above buried plumbing pipe. Native pit run 12 6 N/A Yes 9 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 56” above buried plumbing pipe. Native pit run 12 6 N/A Yes 10 35’ W of Tank 4 1’ below top of tank Native pit run 16 7 N/A Yes 11 35’ W of Tank 4 0” below top of tank Native pit run 12 7 N/A Yes 12 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 68” above buried plumbing pipe. Native pit run 12 6 N/A Yes 13 35’ W of Tank 4 1’ above top of tank Native pit run 12 7 N/A Yes 14 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 1’ above top of tank. Native pit run 12 7 N/A Yes 15 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 2’ above top of tank. Native pit run 12 7 N/A Yes 16 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 3’ above top of tank. Native pit run 12 7 N/A Yes 17 35’ W of Tank 4 2’ above top of tank Native pit run 12 7 N/A Yes 18 35’ W of Tank 4 3’ above top of tank Native pit run 12 7 N/A Yes Method Specification ­03Report #: 04/14/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 2 of 5Page 2 of 4 Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number03/20/2024 Jerome BowenConstruction Neibaur, Rick Sunny 55 Not providedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Volvo ECR145EL Exceeds 12psi 0 N/AWacker Neuson DPU5545 12,364.5 VPM 0 N/AVolvo SD115 58,050lbs / 2025 VPM 2 1.5Method Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance16’ Radiusaround Tank 3 5.5’ below topof vault Native pit run 12 15 N/A Yes26’ Radiusaround tank 3 4.5’ below topof vault Native pit run 12 15 N/A Yes36’ radiusaround Tank 3 3.5’ below topof tank Native pit run 12 15 N/A Yes46’ radiusaround Tank 3 2.5’ below topof tank Native pit run 12 15 N/A Yes56’ radiusaround Tank 3 1.5’ below topof tank Native pit run 12 15 N/A Yes6From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.20” aboveburiedplumbingpipe.Native pit run 16 6 N/A Yes7From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.32” aboveburiedplumbingpipe.Native pit run 12 6 N/A Yes8From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.44” aboveburiedplumbingpipe.Native pit run 12 6 N/A Yes9From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.56” aboveburiedplumbingpipe.Native pit run 12 6 N/A Yes1035’ W of Tank4 1’ below topof tank Native pit run 16 7 N/A Yes1135’ W of Tank4 0” below topof tank Native pit run 12 7 N/A Yes12From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.68” aboveburiedplumbingpipe.Native pit run 12 6 N/A Yes1335’ W of Tank4 1’ above topof tank Native pit run 12 7 N/A Yes14From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.1’ above topof tank.Native pit run 12 7 N/A Yes15From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.2’ above topof tank.Native pit run 12 7 N/A Yes 16 From 22’ W of Tank 3 to 54’ W of tank 3 and from 25’ S of tank 4 to tank 4. 3’ above top of tank. Native pit run 12 7 N/A Yes 17 35’ W of Tank 4 2’ above top of tank Native pit run 12 7 N/A Yes 18 35’ W of Tank 4 3’ above top of tank Native pit run 12 7 N/A Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: Method specification performed in accordance with ISPWC section 306 and 202. It was discussed with Troy Posio, plate compactor being used for compaction was suitable for use. Plate compactor used for records 1­5, HOPAC used for records 6­9, 12, 14­16, and 18, and roller used for 10, 11, 13, and 17. Dylan with Jerome as notified of inspection results. Email sent to all approved recipients. Photo Documentation Below Area of backfill around Tank 3. HOPAC and Plate compactor used for compaction. Area of backfill S of Tank 4 E of Tank 3. HOPAC used for compaction. ✔ Method Specification ­03Report #: 04/14/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 3 of 5Page 3 of 4 Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number03/20/2024 Jerome BowenConstruction Neibaur, Rick Sunny 55 Not providedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Volvo ECR145EL Exceeds 12psi 0 N/AWacker Neuson DPU5545 12,364.5 VPM 0 N/AVolvo SD115 58,050lbs / 2025 VPM 2 1.5Method Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance16’ Radiusaround Tank 3 5.5’ below topof vault Native pit run 12 15 N/A Yes26’ Radiusaround tank 3 4.5’ below topof vault Native pit run 12 15 N/A Yes36’ radiusaround Tank 3 3.5’ below topof tank Native pit run 12 15 N/A Yes46’ radiusaround Tank 3 2.5’ below topof tank Native pit run 12 15 N/A Yes56’ radiusaround Tank 3 1.5’ below topof tank Native pit run 12 15 N/A Yes6From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.20” aboveburiedplumbingpipe.Native pit run 16 6 N/A Yes7From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.32” aboveburiedplumbingpipe.Native pit run 12 6 N/A Yes8From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.44” aboveburiedplumbingpipe.Native pit run 12 6 N/A Yes9From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.56” aboveburiedplumbingpipe.Native pit run 12 6 N/A Yes1035’ W of Tank4 1’ below topof tank Native pit run 16 7 N/A Yes1135’ W of Tank4 0” below topof tank Native pit run 12 7 N/A Yes12From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.68” aboveburiedplumbingpipe.Native pit run 12 6 N/A Yes1335’ W of Tank4 1’ above topof tank Native pit run 12 7 N/A Yes14From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.1’ above topof tank.Native pit run 12 7 N/A Yes15From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.2’ above topof tank.Native pit run 12 7 N/A Yes16From 22’ W ofTank 3 to 54’W of tank 3and from 25’S of tank 4 totank 4.3’ above topof tank.Native pit run 12 7 N/A Yes1735’ W of Tank4 2’ above topof tank Native pit run 12 7 N/A Yes1835’ W of Tank4 3’ above topof tank Native pit run 12 7 N/A YesMaterial Tested per:ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section)Notes:Method specification performed in accordance with ISPWC section 306 and 202. It was discussed with Troy Posio, plate compactorbeing used for compaction was suitable for use. Plate compactor used for records 1­5, HOPAC used for records 6­9, 12, 14­16, and18, and roller used for 10, 11, 13, and 17. Dylan with Jerome as notified of inspection results. Email sent to all approved recipients.Photo Documentation Below Area of backfill around Tank 3. HOPAC and Plate compactor used for compaction. Area of backfill S of Tank 4 E of Tank 3. HOPAC used for compaction. Area of backfill S of Tank 4. Roller used for compaction. ✔ Method Specification ­03Report #: 04/14/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 4 of 5Page 4 of 4 Reviewed and Approved by: Troy Posio Project Manager 04/14/2024 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 03/28/2024 Jerome Bowen Construction Patterson, Julian Cloudy 37 Not Provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Volvo ECR145EL Exceeds 12psi 0 0 Volvo SD115 31248/2025 vpn 2 1 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 10 ft Radius area around sanitary sewer lift staion 6 ft below grade Native 12 15 N/A Yes 2 10 ft Radius area around sanitary sewer lift staion 5 ft below grade Native 12 15 N/A Yes 3 10 ft Radius area around sanitary sewer lift staion 4 ft below grade Native 12 15 N/A Yes 4 10 ft Radius area around sanitary sewer lift staion 3 ft below grade Native 12 12 N/A Yes 5 10 ft Radius area around sanitary sewer lift staion 2 ft below grade Native 12 12 N/A Yes 6 10 ft Radius area around sanitary sewer lift staion 1 ft below grade Native 12 12 N/A Yes Method Specification ­01Report #: 04/01/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 3Page 1 of 2Page 1 of 3 Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number03/28/2024 Jerome BowenConstruction Patterson, Julian Cloudy 37 Not ProvidedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Volvo ECR145EL Exceeds 12psi 0 0Volvo SD115 31248/2025 vpn 2 1Method Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance110 ft Radiusarea aroundsanitarysewer liftstaion 6 ft belowgrade Native 12 15 N/A Yes210 ft Radiusarea aroundsanitarysewer liftstaion 5 ft belowgrade Native 12 15 N/A Yes310 ft Radiusarea aroundsanitarysewer liftstaion 4 ft belowgrade Native 12 15 N/A Yes410 ft Radiusarea aroundsanitarysewer liftstaion 3 ft belowgrade Native 12 12 N/A Yes 5 10 ft Radius area around sanitary sewer lift staion 2 ft below grade Native 12 12 N/A Yes 6 10 ft Radius area around sanitary sewer lift staion 1 ft below grade Native 12 12 N/A Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: Method specification performed in accordance with ISPWC. Dylan with Jerome Bowen as notified of inspection results. Email sent to all approved recipients. Inspections 1­3 were performed with hoepack with compacting attachment, inspections 4­6 performed with vibrating roller. Photo Documentation Below Sanitary sewer lift station. ✔ Method Specification ­01Report #: 04/01/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 2 of 3Page 2 of 2Page 2 of 3 Method Specification ­01Report #: 04/01/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 3 of 3Page 1 of 1Page 3 of 3 Reviewed and Approved by: Troy Posio Project Manager 04/01/2024 Inspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 03/28/2024 Jerome Bowen Construction Patterson, Julian Cloudy 37 Not Provided Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) Volvo ECR145EL Exceeds 12psi 0 0 Volvo SD115 31248/2025 vpn 2 1 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 10 ft Radius area around sanitary sewer lift staion 6 ft below grade Native 12 15 N/A Yes 2 10 ft Radius area around sanitary sewer lift staion 5 ft below grade Native 12 15 N/A Yes 3 10 ft Radius area around sanitary sewer lift staion 4 ft below grade Native 12 15 N/A Yes 4 10 ft Radius area around sanitary sewer lift staion 3 ft below grade Native 12 12 N/A Yes 5 10 ft Radius area around sanitary sewer lift staion 2 ft below grade Native 12 12 N/A Yes 6 10 ft Radius area around sanitary sewer lift staion 1 ft below grade Native 12 12 N/A Yes Method Specification ­00Report #: 03/28/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 3Page 1 of 2 Inspection DetailsDateContractor Inspector Weather AmbientTemperature (°F)Permit Number03/28/2024 Jerome BowenConstruction Patterson, Julian Cloudy 37 Not ProvidedCompaction EquipmentModel:Weight/Vibration Number of Tires Speed (mph)Volvo ECR145EL Exceeds 12psi 0 0Volvo SD115 31248/2025 vpn 2 1Method Specification InspectionTest #Location orStation Elevation MaterialPlaced LiftThickness(in)# of FullPasses Density (pcf)(if applicable)InCompliance110 ft Radiusarea aroundsanitarysewer liftstaion 6 ft belowgrade Native 12 15 N/A Yes210 ft Radiusarea aroundsanitarysewer liftstaion 5 ft belowgrade Native 12 15 N/A Yes310 ft Radiusarea aroundsanitarysewer liftstaion 4 ft belowgrade Native 12 15 N/A Yes410 ft Radiusarea aroundsanitarysewer liftstaion 3 ft belowgrade Native 12 12 N/A Yes 5 10 ft Radius area around sanitary sewer lift staion 2 ft below grade Native 12 12 N/A Yes 6 10 ft Radius area around sanitary sewer lift staion 1 ft below grade Native 12 12 N/A Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: Method specification performed in accordance with ISPWC. Dylan with Jerome Bowen as notified of inspection results. Email sent to all approved recipients. Inspections 1­3 were performed with hoepack with compacting attachment, inspections 4­6 performed with vibrating roller. Photo Documentation Below Sanitary sewer lift station. ✔ Method Specification ­00Report #: 03/28/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: CkQ Rexburg 2, LLC PO Box 911839 ST. George, UT 84791 Project: E232004c Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID 1365 NORTH 2ND EAST Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 2 of 3Page 2 of 2