HomeMy WebLinkAboutDAILY REPORTS - 23-00669 - Tagg N Go - Car WashInspection Details
Date Contractor Inspector Weather Ambient
Temperature (°F)
Permit Number
02/14/2024 Richardson Concrete Smith, Kyle Snowing 29 230069
Remarks
Atlas representative arrived onsite at 07:00 am. Upon arriving at the site, Atlas representative checked in with Blain from Richardson Concrete.
Atlas representative was informed of work requiring testing and inspections. Atlas representative was informed that concrete was canceled. Altas
representative continued with other tasks at 9:00 am.
Daily Inspection Report 01Report #:
02/16/2024Report Date:
Atlas Technical Consultants, LLC Idaho
Falls
1753 E Precision Drive
Idaho Falls, ID 83402
Phone: (208) 5298242
Client:
CkQ Rexburg 2, LLC
PO Box 911839
ST. George, UT 84791
Project:
E232004c
Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID
1365 NORTH 2ND EAST
Rexburg, ID 83440
These test results are only based upon the actual items observed, sampled, inspected or tested as part of the
Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client
approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly,
measurement uncertainty is not applied in this determination unless required by project plans and specifications
or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our
company.
Page 1 of 2Page 1 of 1
Inspection Details
Date Contractor Inspector Weather Ambient
Temperature (°F)
Permit Number
02/26/2024 Jerome Bowen Seay, Ryker rainy 35 Not Provided
Remarks
Atlas representative arrived onsite at 1:00 pm. Upon arriving at the site, Atlas representative checked in with Jerome Bowen representative and
was informed that they were no longer in need of a Method specification.
Daily Inspection Report 01Report #:
02/26/2024Report Date:
Atlas Technical Consultants, LLC Idaho
Falls
1753 E Precision Drive
Idaho Falls, ID 83402
Phone: (208) 5298242
Client:
CkQ Rexburg 2, LLC
PO Box 911839
ST. George, UT 84791
Project:
E232004c
Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID
1365 NORTH 2ND EAST
Rexburg, ID 83440
These test results are only based upon the actual items observed, sampled, inspected or tested as part of the
Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client
approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly,
measurement uncertainty is not applied in this determination unless required by project plans and specifications
or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our
company.
Page 1 of 2Page 1 of 1
Inspection Details
Date Contractor Inspector Weather Ambient
Temperature (°F)
Permit Number
03/04/2024 Jerome Bowen
construction
Sanderson, James Snowy 23 Not provided
Remarks
Atlas representative arrived onsite at 12:30 pm. Upon arriving at the site, Atlas representative checked in with Gene with Jerome Bowen. Atlas
representative was informed of work requiring testing and inspections. Gene wanted the Atlas rep to observe compaction of material for the
roadway. The material was 31.8 degrees and there was noticeable chunks of ice in the material. Gene wanted a record of the compaction of this
material with a Volvo R5 vibratory roller, despite not being in compliance, with the understanding that Jerome Bowen would fix any problems in the
roadway come spring and just needed the road accessible. The rep observed the compaction of a lift from the west center manhole to the end of
the road by the carwash, 24 inches below grade. Another lift was added to the last 50 feet of the roadway to bring it up to the 24 inches below
grade. The rep noticed slight pumping 60 feet South and 6 feet East of the manhole. The rep was then informed Jerome Bowen was done for the
day. The rep wrote the daily, and left the jobsite at 13:50.
Photo Documentation Below
Compacted roadway taken from the West Middle manhole
Daily Inspection Report 00Report #:
03/04/2024Report Date:
Atlas Technical Consultants, LLC Idaho
Falls
1753 E Precision Drive
Idaho Falls, ID 83402
Phone: (208) 5298242
Client:
CkQ Rexburg 2, LLC
PO Box 911839
ST. George, UT 84791
Project:
E232004c
Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID
1365 NORTH 2ND EAST
Rexburg, ID 83440
These test results are only based upon the actual items observed, sampled, inspected or tested as part of the
Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client
approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly,
measurement uncertainty is not applied in this determination unless required by project plans and specifications
or specified by contract. This report shall not be reproduced, except in full, without prior written approval from our
company.
Page 1 of 2Page 1 of 1
Inspection Details
Date Contractor Inspector Weather Ambient
Temperature (°F)
Permit Number
04/12/2024 Richardson Concrete Rowley, Daniel Sunny 46 Not Provided
Remarks
For photos. West end of wash bay.
Photo Documentation Below
Before
After
Daily Inspection Report 00Report #:
04/14/2024Report Date:
Atlas Technical Consultants, LLC Idaho
Falls
1753 E Precision Drive
Idaho Falls, ID 83402
Phone: (208) 5298242
Client:
CkQ Rexburg 2, LLC
PO Box 911839
ST. George, UT 84791
Project:
E232004c
Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID
1365 NORTH 2ND EAST
Rexburg, ID 83440
These test results are only based upon the actual items observed, sampled, inspected or tested as part of the
Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client
approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly,
measurement uncertainty is not applied in this determination unless required by project plans and specifications
or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas.
The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a
felony under Federal Statute.
Page 1 of 2Page 1 of 1
Inspection Details
Date Contractor Inspector Weather Ambient
Temperature (°F)
Permit Number
05/06/2024 Jerome Bowen Mathie, Caysen Rainy 39 Not provided
Remarks
Atlas representative arrived onsite at 1pm. Upon arriving at the site, Atlas representative checked in with Dylan with Jerome Bowen. Atlas
representative was informed of cancellation of concrete pour. Email sent to all approved recipients.
Daily Inspection Report DI00000100Report #:
05/07/2024Report Date:
Atlas Technical Consultants, LLC Idaho
Falls
1753 E Precision Drive
Idaho Falls, ID 83402
Phone: (208) 5298242
Client:
CkQ Rexburg 2, LLC
PO Box 911839
ST. George, UT 84791
Project:
E232004c
Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID
1365 NORTH 2ND EAST
Rexburg, ID 83440
These test results are only based upon the actual items observed, sampled, inspected or tested as part of the
Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client
approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly,
measurement uncertainty is not applied in this determination unless required by project plans and specifications
or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas.
The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a
felony under Federal Statute.
Page 1 of 2Page 1 of 1
Reviewed and Approved by: Troy Posio
Project Manager 05/07/2024
Inspection Details
Date Contractor Inspector Weather Ambient
Temperature (°F)
Permit Number
06/19/2024 Richardson concrete Lake, Noah Sunny 58 Not provided
Remarks
Atlas representative arrived onsite at 10:20am11:00am. Upon arriving at the site, Atlas representative checked in with Shawn with Richardson
concrete. Concrete was placed prior to Atlas arriving on site and a test would not provide an accurate information of concrete. Email sent to all
approved recipients.
Daily Inspection Report DI00000201Report #:
06/19/2024Report Date:
Atlas Technical Consultants, LLC Idaho
Falls
1753 E Precision Drive
Idaho Falls, ID 83402
Phone: (208) 5298242
Client:
CkQ Rexburg 2, LLC
PO Box 911839
ST. George, UT 84791
Project:
E232004c
Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID
1365 NORTH 2ND EAST
Rexburg, ID 83440
These test results are only based upon the actual items observed, sampled, inspected or tested as part of the
Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client
approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly,
measurement uncertainty is not applied in this determination unless required by project plans and specifications
or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas.
The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a
felony under Federal Statute.
Page 1 of 2Page 1 of 1
Reviewed and Approved by: Troy Posio
Project Manager 06/19/2024
Inspection Details
Date Contractor Inspector Weather Ambient
Temperature (°F)
Permit Number
06/19/2024 Richardson concrete Lake, Noah Sunny 58 Not provided
Remarks
Atlas representative arrived onsite at 10:20am11:00am. Upon arriving at the site, Atlas representative checked in with Shawn with Richardson
concrete. Concrete was placed prior to Atlas arriving on site and a test would not provide an accurate information of concrete. Email sent to all
approved recipients.
Daily Inspection Report DI00000200Report #:
06/19/2024Report Date:
Atlas Technical Consultants, LLC Idaho
Falls
1753 E Precision Drive
Idaho Falls, ID 83402
Phone: (208) 5298242
Client:
CkQ Rexburg 2, LLC
PO Box 911839
ST. George, UT 84791
Project:
E232004c
Tagg n Go Carwash, 1365 N 2nd E, Rexburg, ID
1365 NORTH 2ND EAST
Rexburg, ID 83440
These test results are only based upon the actual items observed, sampled, inspected or tested as part of the
Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client
approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly,
measurement uncertainty is not applied in this determination unless required by project plans and specifications
or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas.
The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a
felony under Federal Statute.
Page 1 of 2Page 1 of 1