Loading...
HomeMy WebLinkAboutXHEZ.F-C-2516 UL Product iQ - 22-00795 - Madison Station Apartments - Bldg 1Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified. XHEZ - Through-penetration Firestop Systems XHEZ7 - Through-penetration Firestop Systems Certified for Canada See General Information for Through-penetration Firestop Systems See General Information for Through-penetration Firestop Systems Certified for Canada System No. F-C-2516 October 31, 2019 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Rating — 1 Hr F Rating — 1 Hr T Ratings — 1/2 and 1 Hr (See Items 3A and 3A1) FT Ratings — 1/2 and 1 Hr (See Items 3A and 3A1) FH Rating — 1 Hr FTH Ratings — 1/2 and 1 Hr (See Items 3A and 3A1) Fe e d b a c k System tested with a pressure differential of 2.5 Pa between the exposed and the unexposed surfaces with the higher pressure on the exposed side. 1.Floor-Ceiling Assembly — The 1 hr fire-rated solid or trussed lumber joist floor-ceiling assembly shall be constructed of the materials and in the manner specified in the individual L500 Series Floor-Ceiling Designs in the UL Fire Resistance Directory. The general construction features of the floor-ceiling assembly are summarized below: A.Flooring System — Lumber or plywood subfloor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor-Ceiling Design. Max diam of opening shall be 5-1/2 in. (140 mm). B.Wood Joists* — Nom 10 in. (254 mm) deep (or deeper) lumber, steel or combination lumber and steel joists, trusses or Structural Wood Members* with bridging as required and with ends firestopped. C.Gypsum Board* — Min 1/2 in. (13 mm) thick as specified in the individual Floor-Ceiling Design. Gypsum board secured to wood joists or furring channels as specified in the individual Floor-Ceiling Design. Max diam of opening shall be 5-1/2 in. (140 mm). 1.1.Chase Wall — (Optional, not shown) The through penetrant may be routed (Item 2) through a fire rated or non-rated single, double or staggered wood stud/gypsum wallboard chase wall constructed to include the following construction details: A.Studs — Nom 2 by 6 in. (51 by 152 mm) or double nom 2 by 4 in. (51 by 102 mm) lumber studs. B.Sole Plate — Nom 2 by 6 in. (51 by 152 mm) or parallel 2 by 4 in. (51 by 102 mm) lumber plates, tightly butted. Max diam of opening is 5-1/2 in. (140 mm). C.Top Plate — The double top plate shall consist of two nom 2 by 6 in. (51 by 152 mm) or two sets of parallel 2 by Fe e d b a c k 4 in. (51 by 102 mm) lumber plates, tightly butted. Max diam of opening is 5-1/2 in. (140 mm). D.Gypsum Board* — One layer of min 1/2 in. (13 mm) gypsum board. 2. Through Penetrants — One non-metallic pipe or conduit to be installed concentrically or eccentrically within the opening. Annular space within the firestop system is dependent upon the max diam of penetrant and type of firestop wrap strip used as tabulated in Item 3A. Pipe or conduit to be rigidly supported on both sides of floor-ceiling assembly. The following types and sizes of non-metallic pipes or conduit may be used: A.Polyvinyl Chloride (PVC) Pipe — Nom 4 in. (102 mm) diam (or smaller) Schedule 40 cellular core or solid core PVC pipe for use in vented (drain, waste or vent) or closed (process or supply) piping systems. B.Chlorinated Polyvinyl (CPVC) Pipe — Nom 4 in. (102 mm) diam (or smaller) SDR13.5 CPVC pipe for use in vented (drain, waste or vent) or closed (process or supply) piping systems. C.Rigid Nonmetallic Conduit+ — Nom 4 in. (102 mm) diam (or smaller) PVC conduit installed in accordance with the National Electrical Code (NFPA 70). 3.Firestop System — The firestop system shall consist of the following: A.Fill, Void or Cavity Material* - Wrap Strip — One layer of wrap wrapped around pipe with ends tightly butted and held in place with supplied tape. Wrap strip slid into the annular space such that the wrap strip is centered in the gypsum board ceiling, or extending below lower top plate for half of the wrap strip height. The size of wrap strip for a given size penetrant are shown in table below: HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 648S - 1.5"(38 mm) US, CP 648S - 2"(51 mm) US, CP 648S - 3"(76 mm), CP 648S - 4"(102 mm). Product Designation Nom Pipe Size, in. (mm) Max Opening Diam, in. (mm) Annular Space Min, in. (mm) Annular Space Max, in. (mm) Nom Wrap Strip Length, in. (mm) Nom Wrap Strip Thick, in. (mm) Nom Wrap Strip Width, in. (mm) CP648- S-1.5" US 1-1/2 (38) 3 (76) 3/16 (4.8) 5/16 (8) 6.5 (165) 0.18 (4.6) 1 (25) CP648-S-2" US 2 (51) 3-1/2 (89) 3/16 (4.8) 5/16 (8) 8 (203) 0.18 (4.6) 1 (25) CP648-S-3" US 3 (76) 4 (102) 3/16 (4.8) 5/16 (8) 11.5 (292) 0.18 (4.6) 1-3/4 (45) CP648-S-4" US 4 (102) 5-1/2 (140) 3/8 (10) 3/4 (19) 15.1 (384) 0.36 (9) 1-3/4 (45) The T Rating is 1/2 Hr for penetrants with a nom diam of 2 in (51 mm) or smaller. The T Rating is 0 Hr for nom 3 in. (76 mm) penetrants. The T Rating is 1 Hr for nom 4 in. (102 mm) penetrants. A1.Fill, Void or Cavity Material* - Wrap Strip — (As an alternate to the wrap strip in Item 3A) — Layers of intumescent wrap strip are continuously wrapped around the pipe with ends held in place with tape. Wrap strip slid into the annular space such that the wrap strip is centered in the gypsum board ceiling, or extending below lower top plate for half of the wrap strip height. The number of layers of wrap strip for a given size penetrant are shown in table below: HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP648-E W45/1-3/4" Firestop Wrap Strip Fe e d b a c k Product Designation Nom Pipe Size, in. (mm) Max Opening Diam, in. (mm) Annular Space Min, in. (mm) Annular Space Max, in. (mm) Number of Layers Nom Wrap Strip Width, in. (mm) CP648-E W45/1-3/4" 1-1/2 (38) 3 (76) 3/16 (4.8) 5/16 (8) 1 1-3/4 (45) CP648-E W45/1-3/4" 2 (51) 3-1/2 (89) 3/16 (4.8) 5/16 (8) 1 1-3/4 (45) CP648-E W45/1-3/4" 3 (76) 4 (102) 3/16 (4.8) 5/16 (8) 1 1-3/4 (45) CP648-E W45/1-3/4" 3 (76) 5 (127) 3/8 (10) 5/8 (16) 2 1-3/4 (45) CP648-E W45/1-3/4" 4 (102) 6 (152) 3/8 (10) 5/8 (16) 2 1-3/4 (45) The T Rating is 1/2 Hr when CP648-E is used. B.Fill, Void or Cavity Material* - Sealant — Min 1/2 in. (13 mm) thickness applied within the anulus, flush with the bottom surface of the ceiling or lower top plate. An additional min 1/2 in. (13 mm) bead applied around periphery of wrap strip, at the wrap strip gypsum board interface or at the underside of the top plate. Min 3/4 in (19 mm) depth applied within the annulus, flush with the top surface of the floor or the top surface of the sole plate. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-ONE-MAX Intumescent Sealant * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. +Bearing the UL Listing Mark. Last Updated on 2019-10-31 The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL Solutions' Follow - Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL Solutions' Follow - Up Service. Always look for the Mark on the product. UL Solutions permits the reproduction of the material contained in Product iQ subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from Product iQ with permission from UL Solutions" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "©2023 UL LLC." Fe e d b a c k