HomeMy WebLinkAboutTYLER FLANGED FITTINGS - 22-00795 - Madison Station Apartments - Bldg 1 Tyler Pipe/Utilities Division • Box 2027 • Tyler, Texas 75710 • (800) 527-8478 28 Union Foundry Company • Box 309 • Anniston, Alabama 36202 • (800) 226-7601 02/01/07 Tyler/Union DUCTILE IRON C110 FLANGED FITTINGS Sizes 3" thru 12" UL Listed for Fire Main Equipment SAMPLE SPECIFICATION Flanged Fittings, 2" through 48" shall be manufactured of Ductile Iron in accordance with all applicable terms and provisions of standards ANSI/AWWA C110/A21.10 (current revisions). Flange surface shall be faced and drilled in accordance with ANSI Class 125 B16.1. All Ductile Iron Flanged Fittings shall be rated for water pressure of 250 PSI. NOTE: Fittings are CEMENT-LINED and seal coated in accordance with ANSI/AWWA C104/A21.4, also available prime coated, bare or epoxy coated.All coated fittings shall be in accordance with NSF-61. Interiors shall be lined and seal coated in accordance with ANSI/AWWA C104/A21.04, “Cement-mortor Lining for Ductile Iron Pipe and Fittings for Water” unless otherwise specified. FLANGE DETAILS Nominal Dia. of Flange Pipe Size Flange Bolt Thickness Bolt Hole Number Bolt Dia. Inch O.D. Circle T Diameter of Bolts and Lengths 2 6 4.75 .62 .75 4 Á x 2¼ 3 7.5 6 .75 .75 4 Á x 2½ 4 9 7.5 .94 .75 8 Á x 3 6 11 9.5 1.00 .875 8 ¾ x 3½ 8 13.5 11.75 1.12 .875 8 ¾ x 3½ 10 16 14.25 1.19 1.00 12 Â x 4 12 19 17 1.25 1.00 12 Â x 4 14 21 18.75 1.38 1.125 12 1 x 4½ 16 23.5 21.25 1.44 1.125 16 1 x 4½ 18 25 22.75 1.56 1.25 16 1¿ x 5 20 27.5 25 1.69 1.25 20 1¿ x 5 24 32 29.5 1.88 1.375 20 1¼ x 5½ 30 38.75 36 2.12 1.375 28 1¼ x 6½ 36 46 42.75 2.38 1.675 32 1½ x 7 42 53 49.50 2.62 1.625 36 1½ x 7½ 48 59.50 56.00 2.75 1.625 44 1½ x 8 NOTE: No flange joint material furnished. NOTE: Drilling templates are in multiples of four, so that fittings may be made to face in any quarter. Bolt holes shall straddle the center line. Tyler Pipe/Utilities Division • Box 2027 • Tyler, Texas 75710 • (800) 527-8478 Tyler/Union 02/01/07 Union Foundry Company • Box 309 • Anniston, Alabama 36202 • (800) 226-7601 29 90° Bends (1/4) 45° Bends (1/8) 221/2° Bends (1/16) 111/4° Bends (1/32) Dimensions Dimensions Dimensions Dimensions Size R A Weight R A Weight R A Weight R A Weight 2 3.0 4.5 14 ... ... ... ... ... ... ... ... ... 3 4 5.5 26 3.62 3 20 7.56 3 22 15.25 3 20 4 4.5 6.5 44 4.81 4 36 10.06 4 35 20.31 4 40 6 6 8 67 7.25 5 57 15.06 5 64 30.5 5 56 8 7 9 115 8.44 5.5 105 17.62 5.5 90 35.5 5.5 90 10 9 11 164 10.88 6.5 131 22.62 6.5 130 45.69 6.5 130 12 10 12 236 13.25 7.5 196 27.67 7.5 194 55.81 7.5 193 14 11.5 14 330 12.06 7.5 245 25.12 7.5 250 50.75 7.5 245 16 12.5 15 478 13.25 8 315 27.62 8 315 55.81 8 315 18 14 16.5 527 14.5 8.5 422 30.19 8.5 402 60.94 8.5 385 20 15.5 18 878 16.88 9.5 485 35.19 9.5 505 71.06 9.5 505 24 18.5 22 1085 18.12 11 730 37.69 11 528 76.12 11 760 30 21.5 25 1755 27.75 15 1355 57.81 15 1385 116.75 15 1395 36 24.5 28 2135 35.00 18 1755 72.88 18 1790 147.25 18 1805 42 27.5 31 3055 42.25 21 2600 88.00 21 2665 177.69 21 2680 48 30.5 34 4095 49.50 24 3580 103.06 24 3665 208.12 24 3695 BENDS Note: Base Bends are on page 33 and 34, reducing and long radius 90° bends are on page 33. DUCTILE IRON C110 FLANGED FITTINGS Sizes 3" thru 12" UL Listed for Fire Main Equipment Tyler Pipe/Utilities Division • Box 2027 • Tyler, Texas 75710 • (800) 527-8478 30 Union Foundry Company • Box 309 • Anniston, Alabama 36202 • (800) 226-7601 02/01/07 Tyler/Union DUCTILE IRON C110 FLANGED FITTINGS TEES, REDUCING TEES, CROSSES Straight Tees, Reducing *Reducing *Reducing on *Bullhead Straight and on Branch Tees on Run Run and Branch Tees Reducing Crosses Size Dimensions Weights Run Run Branch H J Tee Cross 2 2 2 4.5 4.5 20 3 3 2 5.5 5.5 35 ... 3 3 3 5.5 5.5 42 51 4 3 3 6.5 5.5 53 ... *4 4 2 6.5 6.5 55 ... 4 4 3 6.5 6.5 54 76 4 4 4 6.5 6.5 60 87 *4 4 6 8.0 8.0 88 ... *6 4 4 8.0 8.0 96 ... *6 4 6 8.0 8.0 100 ... *6 6 2 8.0 8.0 85 ... 6 6 3 8.0 8.0 85 96 6 6 4 8.0 8.0 90 112 6 6 6 8.0 8.0 98 141 6 6 8 9.0 9.0 138 ... *8 6 4 9.0 9.0 130 ... *8 6 6 9.0 9.0 148 ... *8 6 8 9.0 9.0 154 ... 8 8 3 9.0 9.0 128 140 8 8 4 9.0 9.0 155 155 8 8 6 9.0 9.0 148 172 8 8 8 9.0 9.0 179 195 *8 8 10 11.0 11.0 225 ... *8 8 12 12.0 12.0 277 ... *†10 6 6 13.0 13.0 278 ... *†10 6 10 13.0 13.0 308 ... *†10 8 6 13.0 13.0 298 ... *†10 8 8 13.0 13.0 278 ... *†10 8 10 13.0 13.0 325 ... 10 10 4 11.0 11.0 239 220 10 10 6 11.0 11.0 215 242 10 10 8 11.0 11.0 254 294 10 10 10 11.0 11.0 265 330 10 10 12 12.0 12.0 337 ... * †12 6 6 14.0 14.0 346 ... *†12 6 8 14.0 14.0 362 ... *†12 8 6 14.0 14.0 355 ... Size Dimensions Weights Run Run Branch H J Tee Cross *12 8 8 12.0 12.0 375 ... *12 8 12 12.0 12.0 420 ... *†12 10 6 14.0 14.0 390 ... 12 10 8 12.0 12.0 400 ... 12 10 10 12.0 12.0 420 ... 12 10 12 12.0 12.0 440 ... 12 12 4 12.0 12.0 322 310 12 12 6 12.0 12.0 297 326 12 12 8 12.0 12.0 346 351 12 12 10 12.0 12.0 394 415 12 12 12 12.0 12.0 369 438 *14 14 4 14.0 14.0 410 ... 14 14 6 14.0 14.0 420 450 14 14 8 14.0 14.0 435 475 14 14 10 14.0 14.0 450 ... 14 14 12 14.0 14.0 470 555 14 14 14 14.0 14.0 500 595 *16 16 4 15.0 15.0 525 ... 16 16 6 15.0 15.0 573 565 16 16 8 15.0 15.0 555 590 16 16 10 15.0 15.0 565 620 16 16 12 15.0 15.0 590 665 16 16 14 15.0 15.0 610 ... 16 16 16 15.0 15.0 635 755 18 18 6 13.0 15.5 780 ... 18 18 8 13.0 15.5 609 ... 18 18 10 13.0 15.5 585 ... 18 18 12 13.0 15.5 638 706 18 18 14 16.5 16.5 808 ... 18 18 16 16.5 16.5 760 ... 18 18 18 16.5 16.5 865 915 * Not included in AWWA C110 † H and J dimensions are two-inches longer than straight tees. Tyler Pipe/Utilities Division • Box 2027 • Tyler, Texas 75710 • (800) 527-8478 Tyler/Union 02/01/07 Union Foundry Company • Box 309 • Anniston, Alabama 36202 • (800) 226-7601 31 TEES, REDUCING TEES, CROSSES (Con't) Size Dimensions Weights Run Run Branch H J Tee Cross 20 20 6 14.0 17.0 773 ... 20 20 8 14.0 17.0 720 ... 20 20 10 14.0 17.0 735 ... 20 20 12 14.0 17.0 816 820 20 20 14 14.0 17.0 770 ... 20 20 16 18.0 18.0 950 1065 20 20 18 18.0 18.0 965 ... 20 20 20 18.0 18.0 1005 1175 24 24 6 15.0 19.0 1089 ... 24 24 8 15.0 19.0 1060 ... 24 24 10 15.0 19.0 1020 ... 24 24 12 15.0 19.0 1125 1100 24 24 14 15.0 19.0 1050 1125 24 24 16 15.0 19.0 1070 1160 24 24 18 22.0 22.0 1534 ... 24 24 20 22.0 22.0 1510 1695 24 24 24 22.0 22.0 1685 1850 *30 30 6 18.0 23.0 1725 ... 30 30 12 18.0 23.0 1801 ... 30 30 18 18.0 23.0 1852 ... 30 30 24 25.0 25.0 2475 2695 30 30 30 25.0 25.0 2615 2985 36 36 24 20.0 26.0 2255 ... 36 36 30 28.0 28.0 3000 ... 36 36 36 28.0 28.0 3160 ... 42 42 24 23.0 30.0 3245 ... 42 42 30 31.0 31.0 4125 ... 42 42 36 31.0 31.0 5360 ... 42 42 42 31.0 31.0 5580 ... 48 48 24 28.0 34.0 4385 ... 48 48 30 26.0 34.0 4455 ... 48 48 36 34.0 34.0 5555 ... 48 48 42 34.0 34.0 7195 ... 48 48 48 34.0 34.0 7385 ... * Not included in AWWA C110 *Flange and Flare 90° Ell Dimensions Size D X Y Weight 3 7.5 5.5 8.5 26 4 9.0 6.5 9.5 39 6 11.0 8.0 12.0 73 8 13.5 9.0 13.0 110 10 16.0 11.0 15.0 171 12 19.0 12.0 16.0 253 14 21.0 14.0 22.0 450 16 23.5 15.0 23.0 545 18 25.0 16.5 24.5 675 20 27.5 18.0 26.0 860 24 32.0 22.0 30.0 1195 * Not included in AWWA C110 FLANGE AND FLARE *Flange and Flare Piece Dimensions Size D L Weight 3 7.25 8 21 4 9.00 8 30 6 11.00 8 44 8 13.50 10 75 10 16.00 10 113 12 19.00 12 155 14 21.00 16 225 16 23.50 16 330 18 25.00 16 355 20 27.50 18 465 24 32.00 18 598 DUCTILE IRON C110 FLANGED FITTINGS Tyler Pipe/Utilities Division • Box 2027 • Tyler, Texas 75710 • (800) 527-8478 32 Union Foundry Company • Box 309 • Anniston, Alabama 36202 • (800) 226-7601 02/01/07 Tyler/Union NOTE: Eccentric Reducers Offset 1/2 D minus 1/2 D1=Offset Example: 6x3 Ecc.Reducer 3-1½ = 1½" Offset NOTE: Eccentric Reducers not included in AWWA C110 Size Dimensions Wts D D 1 L 3 2 6 17 4 2 7 23 4 3 7 29 6 2 9 30 6 3 9 44 6 4 9 46 6 5 9 56 8 3 11 61 8 4 11 63 8 5 11 70 8 6 11 75 10 4 12 98 10 6 12 107 10 8 12 116 12 4 14 119 12 6 14 130 12 8 14 152 12 10 14 178 14 6 16 165 14 8 16 185 14 10 16 205 14 12 16 235 16 6 18 210 16 8 18 230 16 10 18 255 16 12 18 285 16 14 18 315 Size Dimensions Wts D D 1 L 4 3 7 30 6 3 9 45 6 4 9 52 8 4 11 70 8 6 11 80 10 6 12 98 10 8 12 123 12 6 14 135 12 8 14 149 12 10 14 177 16 6 18 210 16 8 18 230 16 10 18 255 16 12 18 285 16 14 18 315 18 8 19 265 18 10 19 290 18 12 19 306 Concentric Reducer Eccentric Reducer 18 8 19 265 18 10 19 290 18 12 19 320 18 14 19 350 18 16 19 405 20 10 20 418 20 12 20 465 20 14 20 430 20 16 20 445 20 18 20 470 24 12 24 608 24 14 24 565 24 16 24 610 24 18 24 645 24 20 24 695 30 16 30 945 30 18 30 970 30 20 30 1144 30 24 30 1155 42 24 42 1810 42 30 42 2060 42 36 42 2345 48 30 48 2615 48 36 48 2940 48 42 48 3320 Size Dimensions Wts D D 1 L 18 14 19 350 18 16 19 385 20 10 20 350 20 12 20 370 20 14 20 402 20 16 20 449 20 18 20 455 24 12 24 535 24 14 24 570 24 16 24 614 24 18 24 645 24 20 24 695 42 24 42 1820 42 30 42 2060 42 36 42 2345 48 30 48 2625 48 36 48 2950 48 42 48 3320 Size Dimensions Wts D D 1 L DUCTILE IRON C110 FLANGED FITTINGS REDUCERS Tyler Pipe/Utilities Division • Box 2027 • Tyler, Texas 75710 • (800) 527-8478 Tyler/Union 02/01/07 Union Foundry Company • Box 309 • Anniston, Alabama 36202 • (800) 226-7601 33 BASE BENDS, BASE TEES Base Bends are made to order only, not returnable. Bases are furnished faced and drilled. DUCTILE IRON C110 FLANGED FITTINGS 90° Base Bend (1/4) *90° Long Radius Base Bend (1/4) Base Tees *90° Long Radius Bend (1/4) Dimensions Size R A Weight 3 6.25 7.75 32 4 7 9 46 6 9.5 11.5 83 8 14 14 140 10 16.5 16.5 252 12 17 19 310 14 19 21.5 475 16 21.5 24 630 * Not included in AWWA C110 *90° Reducing Bend (1/4) Dimensions Size A Weight 4x3 6.5 35 6x4 8 65 8x4 9 88 8x6 9 96 10x6 11 126 10x8 11 151 12x6 12 172 12x8 12 191 12x10 12 218 * Not included in AWWA C110 * WYES BENDS Support Dimensions Pipe Weight Size X S U Size 90° 90°LR Tee 3 4.88 5 .50 1.5 38 41 47 4 5.5 6 .50 2 50 60 76 6 7 7 .62 2.5 83 100 115 8 8.38 9 .88 4 142 180 195 10 9.75 9 .88 4 210 315 315 12 11.25 11 1.00 6 300 427 450 14 12.5 11 1.00 6 400 580 570 16 13.75 11 1.00 6 505 740 710 18 15 13.5 1.12 8 645 ... 900 20 16 13.5 1.12 8 805 ... 1125 24 18.5 13.5 1.12 8 1215 ... 1927 30 23 16 1.15 10 1945 ... ... * Not included in AWWA C110 *45° Wye Size Dimensions Run Branch H J Weight 3 3 10 3 49 4 3 12 3 68 4 4 12 3 76 6 4 14.5 3.5 106 6 6 14.5 3.5 131 8 4 17.5 4.5 153 8 6 17.5 4.5 188 8 8 17.5 4.5 201 10 4 20.5 5 232 10 6 20.5 5 288 10 8 20.5 5 333 10 10 20.5 5 300 12 4 24.5 5.5 355 12 6 24.5 5.5 370 12 8 24.5 5.5 395 12 10 24.5 5.5 420 12 12 24.5 5.5 460 14 6 27 6 500 14 8 27 6 525 14 10 27 6 555 14 12 27 6 600 14 14 27 6 640 16 6 30 6.5 655 16 8 30 6.5 680 16 10 30 6.5 715 16 12 30 6.5 755 16 14 30 6.5 800 16 16 30 6.5 850 18 8 32 7 820 18 10 32 7 855 18 12 32 7 1003 18 14 32 7 940 18 16 32 7 990 18 18 32 7 1035 20 10 35 8 1095 20 12 35 8 1130 20 14 35 8 1170 20 16 35 8 1220 20 20 35 8 1345 24 24 40.5 9 2020 * Not included in AWWA C110 True Wye Size Dimensions Stem Branches X Y Weight 4 4 6.5 3.0 49 6 4 8.0 3.5 75 6 6 8.0 3.5 84 8 6 9.0 4.5 134 8 8 9.0 4.5 125 * Not included in AWWA C110 Tyler Pipe/Utilities Division • Box 2027 • Tyler, Texas 75710 • (800) 527-8478 34 Union Foundry Company • Box 309 • Anniston, Alabama 36202 • (800) 226-7601 02/01/07 Tyler/Union DUCTILE IRON C110 FLANGED FITTINGS * FLANGE SLUDGE SHOE FLANGES Flange for DI Pipe Reducing Flange for DI Pipe Flange for Steel Pipe Reducing Flange for Steel Pipe Dimensions Weight Size O Q Y Z Steel DI Blind Blind Tap 2 6 .62 1 4.75 4 ... ... ... 2½ 7 .69 1.13 5.50 8 ... ... ... 3 7.5 .75 1.19 6.00 7 6 8 8 4 9 .94 1.31 7.50 12 11 15 15 6 11 1.00 1.56 9.50 21 14 28 28 8 13.5 1.12 1.75 11.75 28 34 45 45 10 16 1.19 1.94 14.25 49 33 62 62 12 19 1.25 2.19 ... 61 52 72 87 14 21 1.38 2.25 ... ... 72 110 110 16 23.5 1.44 2.5 ... ... 90 165 165 18 25 1.56 2.69 ... ... 105 192 190 20 27.5 1.69 2.88 ... ... 115 249 250 24 32 1.88 3.25 ... ... 160 375 370 30 38.75 2.12 ... ... ... 255 580 580 36 46.00 2.38 ... ... ... ... 790 ... 42 53.00 2.62 ... ... ... ... 1175 ... 48 59.50 2.75 ... ... ... ... 1585 ... NOTE: All flanges conform to ANSI/AWWA C110/A21.10 Standards. Under 12" Blind Flange With Optional 2" Taps 12" and Larger Blind Flange With Optional 2" Taps DI Reducing Flange DI Reducing Flange Threaded For Steel Pipe Threaded For Cast Iron Pipe Size Tap x O.D. Weight Size Tap x O.D. Weight 4x3 3x9 16 4x3 3x9 16 6x4 4x11 25 6x4 4x11 25 8x4 4x13½ 44 8x4 4x13½ 40 8x6 6x13½ 31 8x6 6x13½ 35 10x6 6x16 50 10x8 8x16 50 12x6 6x19 60 12x8 8x19 85 10x8 8x16 55 12x10 10x19 72 Flange Sludge Shoe Dimensions Size D X Y Weight 3 5.75 12 6 28 4 7.00 12 6 35 6 7.87 12 6 45 8 10.12 12 6 69 10 12.25 12 6 88 12 15.25 12 6 120 * Not included in AWWA C110 * REDUCING BASE BENDS Base Under Base Under Large End Small End Dimensions Size X S U Weight 4x3 5.5 6 .50 45 6x4 7 7 .62 75 8x4 8.38 9 .88 118 8x6 8.38 9 .88 135 10x6 9.75 9 .88 175 10x8 9.75 9 .88 184 12x6 11.25 11 1.00 230 12x8 11.25 11 1.00 255 12x10 11.25 11 1.00 285 * Not included in AWWA C110 NOTE: “X” dimensions are identical on Base- under-large-end and Base-under-small-end. “S” dimensions are determined by the largest fitting opening. Base Drilling Details Nom. Dimensions - Inches Diameter Bolt Hole Number Inches BC Diameter of Bolts 3 3.88 5/8 4 4 4.75 3/4 4 6 5.50 3/4 4 8 7.50 3/4 4 10 7.50 3/4 4 12 9.50 7/8 4 14 9.50 7/8 4 16 9.50 7/8 4 18 11.75 7/8 4 20 11.75 7/8 4 24 11.75 7/8 4 30 14.25 1 4 36 17.00 1 4 42 21.25 1-1/8 4 48 22.75 1-1/4 4 (If Required) Tyler Pipe/Utilities Division • Box 2027 • Tyler, Texas 75710 • (800) 527-8478 Tyler/Union 02/01/07 Union Foundry Company • Box 309 • Anniston, Alabama 36202 • (800) 226-7601 35 DUCTILE IRON C110 FLANGED FITTINGS Fitting Size Maximum Tap Without Boss 3" .......................1/2" 4" - 6" ................3/4" 8" .......................1-1/4" 10" - 16" ............1-1/2" 18" - 30" ............2" LOCATION OF TAPPED HOLES FOR DRAINS AWWA C110 Flanged Fittings Fittings can be supplied with taps sized and located to ANSI B16.1 and MSS-SP-45. Specify fitting size, tap location by letter (refer to drawings) and tap size by NPT dimension, on order. SPECIAL TAP PRICING POLICY Special taps in fittings apply to C-110 Flanged Fittings only. Flanged Fittings that require a tapping boss will have a one time $200.00 (net) set up charge per boss per position. Consult your Customer Service Representative for current special tap pricing and more details. DUCTILE IRON ADAPTER FLANGE Ductile Iron D F C Pipe OD +.06 +.07 Size +.06 or -.06 -.04 -.03 Weight 3 3.96 4.94 4.06 .94 7 4 4.80 6.02 4.90 1.00 10 6 6.90 8.12 7.00 1.06 14 8 9.05 10.27 9.15 1.12 22 10 11.10 12.34 11.20 1.19 30 12 13.20 14.44 13.30 1.25 40 All set screws are 5/8" 80 lb. torque head. Wall Thickness Note: Recommended for Ductile Iron Pipe Class 53 thru Class 56. Rated No. of No. of Bolt Working Set Bolt Bolt & Size Hole Size Pressure Screws Circle Nuts of Bolt Dia. 3 250 4 6.00 4 Á x2½ ¾ 4 250 4 7.50 8 Á x3 ¾ 6 250 8 9.50 8 ¾x3½ Â 8 250 8 11.75 8 ¾x3½ Â 10 250 12 14.25 12 Â x4 1 12 150 12 17.00 12 Â x4 1 See Index for Installation Instructions Fitting Size Maximum Tap Fitting Maximum Tap Size Without Boss NOTE: A BOSS IS ALWAYS REqUIRED AT “Y” OR “v” ON STRAIGHT AND REDUCING SIzES OF 90-DEGREE ELBOWS, AND ON TAPERED SIDES OF REDUCERS. ADAPTER FLANGES