Loading...
HomeMy WebLinkAboutREDLINED PLANS - 23-00309 - Cedar Point Trucking - Bldg 2 - Shell OnlyAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : Cedar Point Trucking - Bldg 2 - Shell Only Address : 3202 W 5000 S Application Type : Document Filename : STRUCTURAL - Cedarpoint Storage 5-18-23.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments S1.0 Free Text Cody Jones : Building Open 1 Need architectural drawings. Building design criteria. Envelope COMM check. # 23-00309 Madison County - Commercial Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 05.25.2023 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 5/ 1 8 / 2 3 14 1 3 4 D VID B . P O R T E R L I C E N SED SHEET INDEX SHEET DESCRIPTION DETAILS S1.0 GENERAL STRUCTURAL NOTES --- S1.1 TYPICAL DETAILS T-SERIES S1.2 TYPICAL DETAILS T-SERIES S2.0 FOUNDATION PLAN --- S2.1 MEZZANINE FRAMING PLAN --- S3.0 FOUNDATION DETAILS 100 - SERIES S4.0 FRAMING DETAILS 200 - SERIES GENERAL STRUCTURAL NOTES (APPLY UNLESS NOTED OTHERWISE ON PLANS/DETAILS) GENERAL REQUIREMENTS: 1.THE STRUCTURAL SYSTEMS AND MEMBERS DEPICTED HEREIN HAVE BEEN DESIGNED PRIMARILY TO SAFEGUARD AGAINST MAJOR STRUCTURAL DAMAGE AND LOSS OF LIFE, NOT TO LIMIT DAMAGE OR MAINTAIN FUNCTION (IBC SECTION 101.3). 2.THESE DRAWINGS, AND THEIR ASSOCIATED STRUCTURAL CALCULATIONS, HAVE BEEN PERFORMED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE STRUCTURAL ENGINEER'S IN THIS OR SIMILAR LOCALITIES. THEY NECESSARILY ASSUME THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKMEN WHO HAVE A WORKING KNOWLEDGE OF THE INTERNATIONAL BUILDING CODE CONVENTIONAL FRAMING REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR FRAMING ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, IT IS UNDERSTOOD THAT THE CONTRACTOR WILL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR ALL MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3.THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION SUCH THAT DESIGN LIVE LOAD PER SQUARE FOOT AS STATED HEREIN IS NOT EXCEEDED. OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF AN OPTION IS USED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES, AND SHALL COORDINATE ALL DETAILS. 4.WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. TYPICAL DETAILS AND NOTES ARE NOT NECESSARILY INDICATED ON THE PLANS, BUT SHALL APPLY NONE-THE-LESS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. DETAILS MAY SHOW ONLY ONE SIDE OF CONNECTION OR MAY OMIT INFORMATION FOR CLARITY. 5.ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ARCHITECT AND STRUCTURAL ENGINEER. 6.ANY INSPECTIONS, SPECIAL (IBC CHAPTER 17) OR OTHERWISE THAT ARE REQUIRED BY THE BUILDING CODES, LOCAL BUILDING DEPARTMENTS, OR BY THESE PLANS SHALL BE DONE BY AN INDEPENDENT INSPECTION COMPANY OR THE BUILDING DEPARTMENT, SITE VISITS BY THE STRUCTURAL ENGINEER DO NOT CONSTITUTE AN OFFICIAL INSPECTION, UNLESS SPECIFICALLY CONTRACTED FOR. 7.SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS IN ADDITION TO ITEMS REQUIRED BY ARCHITECTURAL SPECIFICATIONS, THE CONTRACTOR SHALL REVIEW ALL SHOP DRAWINGS PRIOR TO SUBMITTAL. ITEMS NOT IN ACCORDANCE WITH CONTRACT DRAWINGS SHALL BE FLAGGED UPON HIS REVIEW. VERIFY ALL DIMENSIONS WITH ARCHITECT. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM ORIGINAL CONTRACT DRAWINGS SHALL BE CLOUDED. ANY OF THE AFOREMENTIONED WHICH ARE NOT CLOUDED OR FLAGGED BY SUBMITTING PARTIES, SHALL NOT BE CONSIDERED APPROVED AFTER THE STRUCTURAL ENGINEER'S REVIEW, UNLESS NOTED ACCORDINGLY. ANY ENGINEERING PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW, SHALL BEAR THE SEAL OF A STRUCTURAL ENGINEER REGISTERED IN THE APPROPRIATE STATE. THE SHOP DRAWINGS DO NOT REPLACE THE ORIGINAL CONTRACT DRAWINGS. ITEMS OMITTED OR SHOWN INCORRECTLY AND ARE NOT FLAGGED BY THE STRUCTURAL ENGINEER ARE NOT TO BE CONSIDERED CHANGES TO ORIGINAL DRAWINGS. THE ADEQUACY OF ENGINEERING DESIGNS AND LAYOUT PERFORMED BY THE OTHERS RESTS WITH THE DESIGNING OR SUBMITTING AUTHORITY. REVIEWING IS INTENDED ONLY AS AN AID TO THE CONTRACTOR IN OBTAINING CORRECT SHOP DRAWINGS. RESPONSIBILITY FOR CORRECTNESS SHALL REST WITH THE CONTRACTOR. ALLOW (5) WORKING DAYS FOR THE STRUCTURAL ENGINEER'S REVIEW. ONE COPY OF EACH SUBMITTAL WILL BE RETAINED FOR THE STRUCTURAL ENGINEER'S RECORDS. BASIS FOR DESIGN: 1.BUILDING CODE: 2018 EDITION OF THE IBC WITH CITY/COUNTY AMENDMENTS. RISK CATEGORY = II 2.VERTICAL LOAD: PER PRE-ENGINEERED BUILDING MANUFACTURER 3.SEISMIC DESIGN PARAMETERS: PER PRE-ENGINEERED BUILDING MANUFACTURER 4.WIND DESIGN PARAMETERS: PER PRE-ENGINEERED BUILDING MANUFACTURER REINFORCING STEEL: 1.ASTM A615 GRADE 60 (FY = 60 KSI) DEFORMED BARS FOR ALL BARS #4 AND LARGER. ASTM A615 GRADE 40 (FY = 40 KSI) DEFORMED BARS FOR ALL BARS #3 AND SMALLER. GRADE 60 DEFORMED BARS SHALL BE USED FOR CONCRETE WALLS, BEAMS, ELEVATED SLABS AND COLUMN REINFORCING. 2.WELDING OF REINFORCING BARS SHALL BE MADE ONLY TO ASTM A706 GRADE 60 BARS AND ONLY USING E90 SERIES RODS. WELDING OF REINFORCING BARS SHALL BE MADE ONLY AT LOCATIONS SHOWN ON PLANS OR DETAILS. 3.REINFORCING BAR SPACING GIVEN ARE MAXIMUM ON CENTERS. ALL BARS PER CRSI SPECIFICATIONS AND HANDBOOK. DOWEL ALL VERTICAL REINFORCING TO FOUNDATION. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. CONCRETE: 2.ALL NORMAL WEIGHT CONCRETE SHALL BE REGULAR WEIGHT OF 150 POUNDS PER CUBIC FOOT USING HARD-ROCK AGGREGATES. AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. 3.LAP SPLICES FOR BEAMS AND FLOOR SLABS SLABS SHALL BE ACCORDING TO CHAPTER 12 OF ACI 318 OR LAP SCHEDULE ON THESE DRAWINGS. STAGGER SPLICES A MINIMUM OF ONE LAP LENGTH. NO TACK WELDING OF REINFORCING BARS ALLOWED WITHOUT PRIOR REVIEW OF PROCEDURE WITH THE STRUCTURAL ENGINEER. LATEST ACI CODE AND DETAILING MANUAL APPLY. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. VERTICAL WALL BARS SHALL BE SPLICED AT OR NEAR FLOOR LINES. 4.ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING STEEL NOT NOTED AS "CLEAR" OR "CLR" ARE TO CENTER OF STEEL. MINIMUM COVER FOR NON-PRESTRESSED CONCRETE REINFORCING SHALL BE AS FOLLOWS: 5.MAXIMUM SLUMP FOR ALL CONCRETE SHALL BE 6". PORTLAND CEMENT SHALL CONFORM TO ASTM C150. TYPE V CEMENT SHALL BE USED FOR CONCRETE IN CONTACT WITH ALKALINE SOIL, AND TYPE II ELSEWHERE. 6.NO MORE THAN 90 MINUTES SHALL ELAPSE BETWEEN CONCRETE BATCHING AND CONCRETE PLACEMENT UNLESS APPROVED BY THE TESTING AGENCY. 7.CONCRETE PLACEMENT AND QUALITY SHALL BE PER RECOMMENDATIONS IN ACI 614, ACI 301 AND ACI 318. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS ON GRADE NEED BE VIBRATED ONLY AROUND AND UNDER FLOOR DUCTS, ETC. CAST CLOSURE POUR, WHERE SHOWN ON PLANS AROUND COLUMNS AFTER COLUMN DEAD LOAD IS APPLIED. REMOVE ALL DEBRIS FROM FORMS BEFORE PLACING CONCRETE. ALL ITEMS TO BE CAST IN CONCRETE SUCH AS REINFORCING, DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY POSITIONED IN THE FORMS BEFORE PLACING THE CONCRETE. 8.ALL CONCRETE SLABS ON GRADE SHALL BE DIVIDED INTO AREAS BY CONTROL JOINTS (KEYED OR SAW CUT) SUCH THAT ONE SLAB AREA DOES NOT EXCEED A MAXIMUM LENGTH OF 24 TIMES THE SLAB THICKNESS IN BOTH DIRECTIONS (EXAMPLE: 4" SLAB = 8'-0" LENGTH). SQUARE LAYOUTS ARE PREFERRED, BUT THE SLAB GEOMETRY MAY DICTATE OTHERWISE. THE RATIO OF THE LONG TO SHORT DISTANCE SHALL NOT EXCEED 1.3. IT IS RECOMMENDED THAT SAW CUTS BE MADE WITHIN 16 HOURS OF CONCRETE BATCHING. KEYED CONTROL JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING POURING, ALL OTHER JOINTS MAY BE SAW CUT. 9.HORIZONTAL PIPES AND ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE AND SLABS ON GRADE EXCEPT WHERE SPECIFICALLY APPROVED OR NOTED BY THE STRUCTURAL ENGINEER. PIPES AND CONDUITS SHALL NOT IMPAIR THE STRENGTH OF THE WORK. 10.FLY ASH MAY BE USED ONLY IF PERMITTED BY ARCHITECTURAL SPECIFICATIONS AND SHALL BE LIMITED TO 18 PERCENT OF CEMENTITIOUS MATERIALS AND SHALL HAVE A REPLACEMENT FACTOR OF 1.2 RELATIVE TO CEMENT REPLACED. NO FLY ASH ADDITIVES SHALL BE USED IN FLATWORK OR ARCHITECTURALLY EXPOSED CONCRETE. 11.COLD/HOT WEATHER CONCRETE CONSTRUCTION: PROTECT CONCRETE FROM DAMAGE OR REDUCED STRENGTH IN COMPLIANCE WITH ACI 305 AND 306. 12.CONCRETE MIXES SHALL BE DESIGNED BY A CERTIFIED LABORATORY AND APPROVED BY THE STRUCTURAL ENGINEER. 13.LIMIT ALKALI-SILICA REACTION (ASR) TO 0.1% EXPANSION AT 28 DAYS IN CONCRETE MIX AT ALL EXTERIOR CONCRETE AND INTERIOR CONCRETE EXPOSED TO MOISTURE. LOCATION:MINIMUM COVER TOLERANCE CAST AGAINST EARTH (FOOTINGS)3"± 3 8" SLABS ON GRADE 112"± 14" EXPOSED TO EARTH OR WEATHER - #5 AND SMALLER 112"± 3 8" EXPOSED TO EARTH OR WEATHER - #6 AND LARGER 2"± 3 8" NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND ROOF SLAB 1"18" STRUCTURAL SLABS AND WALLS 3 4"18" BEAMS AND COLUMNS (PRIMARY) REINFORCEMENT, TIES, STIRRUPS AND SPIRALS 112"3 8" 1. MINIMUM 28 DAY CONCRETE STRENGTH SHALL BE AS FOLLOWS: USE:CONCRETE STRENGTH: MAX W/C RATIO AIR ENTRAINMENT FOOTINGS 3500 PSI 0.50 5.5% ± 1% CONCRETE WALLS 4500 PSI 0.45 5.5% ± 1% CONCRETE SLABS ON GRADE 3500 PSI 0.45 N/A FOUNDATION NOTES: 1.IN LIEU OF A GEOTECHNICAL REPORT: THE FOUNDATION HAS BEEN DESIGNED ACCORDING TO THE RECOMMENDATIONS OF CHAPTER 18 OF THE IBC. 2.THE SOIL DESIGN VALUES LISTED BELOW HAVE BEEN APPROVED BY THE CITY/COUNTY BUILDING DEPARTMENT, CONTINGENT THAT THE SOIL ON THE SITE PREDOMINATELY CONSISTS OF SAND AND/OR GRAVEL. SPECIFIC SOIL CLASSIFICATIONS SHOULD BE ONE OF THE FOLLOWING: SANDY GRAVEL OR GRAVEL(GW OR GP), SAND(SW AND SP), SILTY SAND(SM), CLAYEY SAND(SC), SILTY GRAVEL(GM), OR CLAYEY GRAVEL(GC). THESE SOIL CLASSIFICATIONS CAN BE FOUND IN TABLE 1806.2 OF CHAPTER 18 OF THE IBC. VERIFICATION OF SOIL CLASSIFICATION IS THE RESPONSIBILITY OF THE CONTRACTOR. 3.A ONE-THIRD INCREASE IN BEARING PRESSURES IS ALLOWED WITH SEISMIC OR WIND LOAD COMBINATIONS. LATERAL BEARING AND LATERAL SLIDING RESISTANCE MAY BE COMBINED. 4.ALL FOUNDATIONS SHALL BEAR ON COMPACTED ENGINEERED FILL OR COMPETENT NATIVE SOIL SUBBASE COMPACTED TO 95% DRY DENSITY (STANDARD PROCTOR). GRADE IS DEFINED AS LOWEST ADJACENT GRADE WITHIN 5 FEET OF THE BUILDING FOR PERIMETER FOOTINGS. WHERE EXTERIOR PAVING OR CONCRETE IS DIRECTLY ADJACENT TO BUILDING, GRADE IS DEFINED AS TOP OF EXTERIOR PAVING AT LEAST 5 FEET FROM BUILDING. CONCRETE FOOTING EXCAVATIONS SHALL BE CLEAN AND FREE OF LOOSE DEBRIS OR UN-COMPACTED MATERIAL AT TIME OF CONCRETE PLACEMENT. 5.CONCRETE SLABS ON GRADE SHALL BE SUPPORTED ON A 4 INCH (MIN) LAYER OF FREE-DRAINING GRANULAR MAT (DRAINAGE FILL COURSE). THE MAT SHOULD CONSIST OF A WELL GRADED SAND AND GRAVEL MIXTURE WITH MAXIMUM 3/4-INCH CRUSHED AGGREGATE. THE GRANULAR MAT SHOULD BE COMPACTED TO NO LESS THAN 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D1557 6.BACKFILL AGAINST RESTRAINED WALLS SHALL NOT BE PLACED UNTIL AFTER THE WALLS ARE SUPPORTED BY THE COMPLETION OF INTERIOR FLOOR SYSTEMS AND CONCRETE OR GROUT STRENGTH HAS REACHED THE 28 DAY STRENGTH LISTED BELOW. THE SOIL DESIGN VALUES FOR THE FOUNDATION ARE: ALLOWABLE BEARING PRESSURE 1500 PSF ALLOWABLE LATERAL BEARING PRESSURE 150 PSF/FT ALLOWABLE LATERAL SLIDING COEFFICIENT 0.25 FOUNDATION BEARING DEPTH 36" BELOW FINISHED GRADE PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 St r u c t u r a l E n g i n e e r i n g fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 co n t a c t @ f r o s t s t r u c t u r a l . c o m S1.0 5/18/23 CE D A R P O I N T S T O R A G E M E T A L B U I L D I N G TI T A N S T E E L RM S DB P IF 2 3 - 0 7 0 GE N E R A L S T R U C T U R A L N O T E S 32 0 2 W 5 0 0 0 S RE X B U R G , I D A H O 8 3 4 4 0 . . . . . . . . . . . . . . . . . . . . . . 7. SEISMIC DESIGN PARAMETERS FOR MEZZANINE: ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE IMPORTANCE FACTOR Ie = 1.00 SITE CLASS D SEISMIC DESIGN CATEGORY D MAPPED SPECTRAL RESPONSE ACCELERATIONS S1 = 0.142, SS = 0.366 DESIGN SPECTRAL RESPONSE ACCELERATIONS SD1 = 0.219, SDS = 0.368 PERCENT LIVE LOAD INCLUDED WITH SEISMIC LOADS 25 VERTICAL SHEAR TRANSFER ELEMENTS: PLYWOOD SHEARWALL(S)R = 6.5, CS = 0.057 5. VERTICAL LOADS FOR MEZZANINE: LOCATION LIVE / SNOW LOAD DEAD LOAD FLOOR 125 PSF 15 PSF 6. DEFLECTION LIMITS FOR MEZZANINE: ELEMENTS LIVE LOAD TOTAL LOAD BEAMS L/360 L/240 STEEL: 1.MATERIALS: ROLLED W SHAPES, SHALL CONFORM TO ASTM A992 (FY=50 KSI). ALL OTHER STRUCTURAL STEEL SHAPES, ROLLED SECTIONS, BARS AND PLATES SHALL CONFORM TO ASTM A36 (FY = 36 KSI). ALL PIPE STEEL SHALL BE ASTM A501 (FY = 36 KSI) OR ASTM A53, TYPE E OR S, GRADE B (FY = 35 KSI). ALL TUBULAR STEEL SHALL BE ASTM A500 GRADE C (FY = 50 KSI). 2.ALL BOLTS AND STUDS SHALL BE ASTM A307, UNLESS NOTED OTHERWISE. ALL EXPANSION BOLTS TO HAVE CURRENT ICC REPORT RATING FOR MATERIAL INTO WHICH INSTALLATION TAKES PLACE. HEADED STUDS SHALL CONFORM TO ALL REQUIREMENTS OF THE LATEST EDITION OF THE "RECOMMENDED PRACTICES FOR STUD WELDING" AND THE "STRUCTURAL WELDING CODE" PUBLISHED BY AWS. ALL BOLTS, ANCHOR BOLTS, EXPANSION BOLTS, ETC. SHALL BE INSTALLED WITH STEEL WASHERS AT FACE OF WOOD OR AT SLOTTED HOLES IN STEEL SECTIONS. 3.ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH AISC SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, LATEST EDITION. 4.WELDING SHALL BE BY WELDERS HOLDING VALID CERTIFICATES AND HAVING CURRENT EXPERIENCE IN THE TYPE OF WELD SHOWN ON THE DRAWINGS OR NOTES. ALL WELDING SHALL USE E70 SERIES LOW HYDROGEN RODS UNLESS NOTED OTHERWISE. ALL WELDING PER LATEST AMERICAN WELDING SOCIETY STANDARDS. ALL WELDS ON DRAWINGS ARE SHOWN AS SHOP WELDS. CONTRACTOR MAY SHOP WELD OR FIELD WELD AT HIS DISCRETION. ALL FULL PENETRATION WELDS SHALL BE TESTED AND CERTIFIED BY AN INDEPENDENT TESTING LABORATORY. 5.STEEL TO STEEL BOLTED CONNECTIONS: HIGH STRENGTH BOLTS SHALL BE ASTM A325N AND SHALL BE INSTALLED AS BEARING-TYPE CONNECTIONS WITH THREADS INCLUDED IN SHEAR PLANE (TYPE "N" CONNECTION UNLESS NOTED OTHERWISE). BOLTS MAY BE TIGHTENED USING ANY AISC APPROVED METHOD. 6.DRYPACK SHALL BE 5,000 PSI FIVE STAR NON-SHRINK GROUT OR EQUIVALENT. INSTALL DRYPACK UNDER BEARING PLATES BEFORE FRAMING MEMBER IS INSTALLED. AT COLUMNS, INSTALL DRYPACK UNDER BASE PLATES AFTER COLUMN HAS BEEN PLUMBED BUT PRIOR TO FLOOR OR ROOF INSTALLATION. WOOD: 1.GENERAL: DO NOT NOTCH OR DRILL JOISTS, BEAMS, OR LOAD BEARING STUDS WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER THROUGH THE ARCHITECT. DOUBLE UP JOISTS AND BLOCKING UNDER PARTITIONS. PROVIDE 2" (NOMINAL) SOLID BLOCKING AT SUPPORTS OF ALL JOISTS. UNLESS NOTED OTHERWISE ON PLANS/DETAILS PROVIDE 2x SOLID BLOCKING AT MID-HEIGHT OF BEARING STUD WALLS. ALL NAILING NOT NOTED SHALL BE ACCORDING TO IBC TABLE 2304.10.1. JOIST HANGERS AND OTHER MISC. FRAMING ANCHORS SHALL BE SIMPSON STRONG-TIE COMPANY, INC. OR OTHER MANUFACTURER WITH CURRENT ICC-ES APPROVAL. 2.SAWN LUMBER: FRAMING LUMBER SHALL COMPLY WITH THE LATEST EDITION OF THE GRADING RULES OF THE WESTERN WOOD PRODUCTS ASSOCIATION (WWPA) OR THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB). ALL SAWN LUMBER SHALL BE STAMPED WITH THE GRADE MARK OF AN APPROVED LUMBER GRADING AGENCY. SAWN LUMBER SHALL HAVE THE FOLLOWING MINIMUM GRADE UNLESS NOTED OTHERWISE IN SCHEDULES: USE:MATERIAL: 2x4 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) 2x6 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) JOISTS, TOP PLATES AND ALL OTHER SAWN LUMBER DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) BEAMS AND POSTS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) LOCATION:NOMINAL THICKNESS: SPAN INDEX RATING: EDGE ATTACHMENT: FIELD ATTACHMENT: WALL 7 16" OR 12"24 16 8d AT 6" O.C.8d AT 12" O.C. ROOF 7 16" OR 12"24 16 8d AT 6" O.C.8d AT 12" O.C. ROOF 15 32" OR 12"32 16 8d AT 6" O.C.8d AT 12" O.C. ROOF 19 32" OR 5 8"40 20 10d AT 6" O.C.10d AT 12" O.C. ROOF 23 32" OR 3 4"48 24 10d AT 6" O.C.10d AT 12" O.C. ROOF 7 8"60 32 10d AT 6" O.C.10d AT 12" O.C. FLOOR 3 4" T&G 48 24 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 7 8" T&G 60 32 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 118" T&G 60 48 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. 3.PLYWOOD: ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING CONFORMING TO STANDARD PS 1-95. LAY UP PLYWOOD WITH FACE GRAIN IN PERPENDICULAR TO SUPPORTS (ON ROOFS WHERE PLYWOOD IS LAID UP WITH FACE GRAIN PARALLEL TO SUPPORTS, USE A MINIMUM OF 5-PLY PLYWOOD, STAGGER JOINTS). ALL NAILING, COMMON NAILS. BLOCKING AT PANEL EDGES WHERE INDICATED ON PLANS. ALL PLYWOOD SHALL BE OF THE FOLLOWING NOMINAL THICKNESS, SPAN/INDEX RATING AND SHALL BE NAILED AS FOLLOWS UNLESS NOTED OTHERWISE ON THE PLANS: SCREWS AT FLOOR SHEATHING SHALL BE #8 SCREWS AND SHALL PENETRATE AT LEAST 112" INTO THE SUPPORTING MEMBER. ALL FLOOR SHEATHING SHALL BE GLUED TO SUPPORTING MEMBERS WITH AN APA AFG-01 QUALIFIED ADHESIVE. PLYWOOD ALTERNATE: AMERICAN PLYWOOD ASSOCIATION PERFORMANCE RATED SHEATHING MAY BE USED AS AN ALTERNATE TO PLYWOOD WITH PRIOR APPROVAL OF OWNER, ARCHITECT AND ROOFER. IT MAY NOT BE USED ON ROOFS WHERE BUILT-UP ROOF SYSTEM IS TO BE GUARANTEED BY ROOFER. RATED SHEATHING SHALL COMPLY WITH CURRENT ICC-ES REPORTS AND SHALL HAVE A SPAN RATING EQUIVALENT TO OR BETTER THAN THE PLYWOOD IT REPLACES. ATTACHMENT AND THICKNESS (WITHIN 132") SHALL BE THE SAME AS THE PLYWOOD IT REPLACES. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 4.NOMINAL 2x AND 3x DECKING. TONGUE AND GROOVE TYPE. MINIMUM Fb = 1,600 PSI, MINIMUM E = 1,300,000 PSI. INSTALL WITH TONGUES UP SLOPE ON PITCHED ROOFS, AND OUTWARD IN THE DIRECTION OF LAYING ON FLAT ROOFS. NAIL EACH PLANK WITH 16d TOENAIL (THRU THE TONGUE) AND 16d FACE NAIL AT EACH SUPPORT. DECK SHALL BE INSTALLED AS SIMPLE SPAN WITH ALL PLANKS BEARING ON TWO SUPPORTS. FOR REFERENCE AND/OR ADDITIONAL INFORMATION SEE AITC 117-2010. 5.GLUED-LAMINATED BEAMS (GLB): GLUED-LAMINATED BEAMS SHALL BE DOUGLAS FIR COMBINATION AT 24F-V4 AT SIMPLE SPAN BEAMS AND 24F-V8 AT MULTI-SPAN AND CANTILEVERED BEAMS WITH THE FOLLOWING MINIMUM PROPERTIES: FB = 2,400 PSI, FV = 190 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,800 KSI. ALL BEAMS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. BEAMS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. CAMBER AS SHOWN ON DRAWINGS. STANDARD CAMBER IS BASED ON A RADIUS OF CURVATURE OF 5000 FEET. 6.GLUED-LAMINATED COLUMNS: GLUED-LAMINATED COLUMNS SHALL BE DOUGLAS FIR COMBINATION 3 WITH THE FOLLOWING MINIMUM PROPERTIES: FBY = 2,100 PSI, FBX = 2000 PSI, FVY = 230 PSI, FVX = 265 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,900 KSI. ALL COLUMNS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. COLUMNS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. 7.LAMINATED VENEER LUMBER (LVL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LVLs SHALL BE: FB = 2,600 PSI, FV = 285 PSI, E = 2,000 KSI. 8.PARALLEL STRAND LUMBER (PSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR PSLs SHALL BE: FB = 2,900 PSI, FV = 290 PSI, E = 2,200 KSI. 9.LAMINATED STRAND LUMBER (LSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LSLs SHALL BE: FB = 2,325 PSI, FV = 310 PSI, E = 1,550 KSI. 10.SILL PLATES RESTING ON CONCRETE OR MASONRY SHALL BE OF TREATED FIR. SHEAR WALLS AND EXTERIOR WALL SILLS AT CONCRETE SLAB SHALL HAVE A MINIMUM OF (2) ANCHOR BOLTS PER PIECE. PROVIDE ANCHOR BOLT AT 9" MAXIMUM, 4" MINIMUM FROM THE END OF EACH PIECE AT SPLICE OR END OF WALL. MAXIMUM ANCHOR BOLT SPACING SHALL BE 72" ON CENTER UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. ALL ANCHOR BOLTS (OTHER THAN BOLTS FOR HOLDOWNS) SHALL EMBED 7" INTO CONCRETE. ANCHOR BOLTS FOR HOLDOWNS SHALL NOT BE CONSIDERED AS PART OF REQUIRED ANCHOR BOLTS ON SHEAR WALLS. ALL EXTERIOR WALLS SHALL BE SECURED WITH MINIMUM ANCHOR BOLTS. INTERIOR WALLS MAY BE SECURED TO CONCRETE WITH EITHER ANCHOR BOLTS OR POWER DRIVEN SHOT PINS UNLESS NOTED OTHERWISE ON PLANS. 11.BOLTING: ALL BOLTS IN WOOD CONNECTIONS SHALL CONFORM TO ASTM A307. BOLTS SHALL BE INSTALLED IN HOLES BORED WITH A BIT 116" LARGER THAN THE Ø (DIAMETER) OF THE BOLT. BOLTS AND NUTS SEATING ON WOOD SHALL HAVE CUT STEEL WASHERS UNDER HEADS AND NUTS. NICK THREADS TO PREVENT LOOSENING. 12.PREFABRICATED WOOD TRUSSES: PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED TO SUPPORT SELF WEIGHT PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS. WHERE UNINHABITABLE ATTIC SPACE CAN BE USED FOR STORAGE, A 20 PSF LIVE LOAD ON THE BOTTOM CHORD SHALL BE INCLUDED IN THE ANALYSIS. BRIDGING SIZE AND SPACING BY TRUSS MANUFACTURER UNLESS NOTED OTHERWISE. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED ENGINEER FOR REVIEW PRIOR TO MANUFACTURE FOR BOTH ROOF AND FLOOR TRUSSES WHEN USED. SHOP DRAWINGS SHALL SHOW ANY SPECIAL DETAILS REQUIRED AT BEARING POINTS. ALL CONNECTORS SHALL HAVE CURRENT ICC-ES APPROVAL. ADDITIONAL TRUSSES SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. PER IBC SECTION 2303.4 AND TPI-1: EACH TRUSS SHALL BE LEGIBLY BRANDED, MARKED OR OTHERWISE HAVE PERMANENTLY AFFIXED THERETO THE IDENTITY OF THE COMPANY MANUFACTURING THE TRUSS, THE DESIGN LOADS, AND THE TRUSS SPACING - WITHIN TWO FEET OF THE CENTER OF THE SPAN ON THE FACE OF THE BOTTOM CHORD. PREFABRICATED WOOD/STEEL WEB JOIST/PURLINS (TJI/TJL SERIES OR EQUAL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST EDITION ICC-ES REPORT. CONNECTIONS AND BEARING MATERIAL TO BE DESIGNED AND FURNISHED BY JOIST FABRICATOR. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED STRUCTURAL ENGINEER FOR REVIEW PRIOR TO MANUFACTURE. ADDITIONAL JOISTS SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. AWWVÑSfUZ>hWUhifS_ÑVfSl>bYg• 3i>_V>bYÑVWg>YbÑUf>hWf>S• 6bjW_cdWÑ4B##ÑUZWU@• KEYNOTES: 1.FINISHED GRADE WHERE OCCURS 2.DO NOT EXCAVATE A TRENCH CLOSER THAN A 45 DEGREE ANGLE TO BELOW BOTTOM FOOTING OR FOUNDATION 3.BOTTOM OF CONCRETE FOOTING 4.BOTTOM OF TRENCH NOTE: A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPE OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS 1 1 1 2 3 4 FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T1 TRENCH PARALLEL TO CONTINUOUS STRAP FOOTING TD01 NO SCALE KEYNOTES: 1.CONCRETE FOOTING 2.SLEEVE - PROVIDE 12" MINIMUM CLEARANCE AROUND PIPE OR CONDUIT 3.PIPE OR CONDUIT 4.CONCRETE FILL TO BE PLACED BEFORE FOOTING IS POURED - FORM SAME AS FOOTING AND POUR FULL WIDTH OF PIPE TRENCH 5.STEM WALL NOTE: A.NO PIPE SHALL PASS THRU FOOTING OR UNDER COLUMN FOOTINGS. FOR TRENCHES GREATER THAN 3'-6" BELOW BOTTOM OF FOOTING, SEE PIPE PASSING BELOW WALL FOOTING DETAIL. 1 2 3 4 5 5 4 2 1 3 T2 PIPE PASSING UNDER WALL FOOTING IN SHALLOW TRENCH TD02 NO SCALE 6" M I N 8" M I N 3' - 0 " M A X 8" MIN A SECTIONA KEYNOTES: 1.STEM WALL 2.CONCRETE FOOTING 3.1'-6" MAXIMUM - WHERE TRENCH EXCEEDS 1'-6" NOTIFY STRUCTURAL ENGINEER PRIOR TO PLACEMENT OF FOOTINGS 4.BACKFILL AND RECOMPACT TRENCH PER SOILS REPORT AND SPECIFICATIONS 5.BOTTOM OF TRENCH NOTE: A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPES OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS 1 5 4 3 2 3' - 1 " O R G R E A T E R FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T3 PIPE PASSING BELOW FOOTING IN DEEP TRENCH TD03 NO SCALE KEYNOTES: 1.SLOPED FINISH GRADE 2.MINIMUM FOOTING DEPTH PER G.S.N. - 12" MINIMUM 3.DEEPEN FOOTING AS REQUIRED TO ACCOUNT FOR SLOPED GRADE 4.CONCRETE FOOTING NOTE: A.FOR ADDITIONAL INFORMATION, SEE PLANS AND DETAILS 1 4 3 2 5'-0" T4 TYPICAL DETAIL FOR FOUNDATION EMBEDMENT TD04 NO SCALE KEYNOTES: 1.CONCRETE SLAB ON GRADE 2.CONT KEYED JOINT 3.SAWCUT 18" WIDE x 14" SLAB THICKNESS IN DEPTH - CUT SHALL BE MADE SOON ENOUGH TO PREVENT SHRINKAGE CRACKING, BUT NOT SO SOON AS TO CAUSE SPALLING OF THE CONCRETE WHILE SAWING. WORK MUST BE COMPLETE WITHIN 16 HOURS OF CONCRETE PLACEMENT. NOTE: A.KEYED JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING PLACEMENT UNLESS SPECIFICALLY NOTED ON THE PLANS. B."TOOL WET JOINT", "ZIP STRIP", ETC SHALL MATCH SAWCUT REQUIREMENTS 1 2 3 1 12"6"6"12" X SAWCUT JOINT X KEYED JOINT T5 CONTROL JOINTS IN CONCRETE SLAB ON GRADE TD07 NO SCALE 6 MIN BAR OFFSET BAR CLEARANCE SPLICE DETAIL BEND & HOOK DETAILS COLUMN TIES BEAM STIRRUPS "d" 45° "d" "d" 1 2 4 5 6 10 9 8 7 3 1 5 5 9 10 8 KEYNOTES: 1.LAP - SEE G.S.N. 2.MAXIMUM 15 LAP BUT NOT MORE THAN 6" 3.WIRE TIES 4.1d (1" MINIMUM) 5.RADIUS = 3d FOR BARS NOT OVER #8; 4d FOR #9, #10, AND #1 BARS; 5d FOR #14 AND #18 BARS, 5d FOR ALL GRADE 40 BARS WITH 180 DEGREE HOOK 6.4D (4" MINIMUM) 7.12d (90 DEGREE HOOK) 8.6d (4" MINIMUM) 9.135 DEGREE BEND 10.BEND AROUND 112" PIN FOR #3 BARS. BEND AROUND 2" PIN FOR #4 BARS. BEND AROUND 212" PIN FOR #5 BARS. T6 TYPICAL REINFORCING DETAILS TD10 NO SCALE NOTES: 1.TOP BARS ARE ANY HORIZONTAL BARS PLACED SO THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT. 2.UNLESS NOTED OTHERWISE, LAP SPLICES IN CONCRETE BEAMS, SLABS AND WALLS SHALL BE CLASS "B" TENSION LAP SPLICES. BAR SIZE CLASS B TENSION SPLICE LENGTHS f'c = 3,000 PSI f'c = 4,000 PSI f'c = 5,000 PSI HOIRZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HOIRZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HOIRZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS #3 12"12"12"12"12"12" #4 19"15"17"13"15"12" #5 29"23"26"20"23"18" #6 32"25"28"21"25"19" #7 54"41"47"36"42"32" #8 70"54"61"47"54"42" #9 89"68"77"59"69"53" #10 112"87"97"75"87"67" T7 STEEL REINFORCING LAP SPLICES IN CONCRETE TD14 NO SCALE KEYNOTES: 1.CORNER DOWELS TO MATCH HORIZONTAL REINFORCEMENT 2.CONCRETE WALL WITH REINFORCEMENT 3.LAP SPLICE PER TYPICAL STEEL REINFORCING LAP SPLICES IN CONCRETE DETAIL T8 TYPICAL CONCRETE CORNER TD05 NO SCALE 2 1 3 3 KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.WOOD HEADER 3.KING STUD(S) PER PLAN 4.(2) 16d NAILS AT 2" O.C. 5.16d NAILS AT 12" O.C. 6.TRIMMER STUD(S) PER PLAN 2 6 3 1 5 4 5 T13 TYPICAL HEADER CONNECTION TD25 NO SCALE KEYNOTES: 1.NAILS BETWEEN SPLICE LOCATION PER SCHEDULE - STAGGERED 2.DBL 2x TOP PLATE 3.WOOD STUD WALL, SEE PLAN 4.SPLICE OVER STUD 5.SIMPSON ST6224 OR MSTC40 STRAP AT LOCATIONS WHERE PLATES CAN NOT BE SPLICED NOTE: A.DO NOT SPLICE TOP PLATES WITHIN 6'-0" OF ENDS OF PLYWOOD SHEARWALLS. THIS DETAIL REQUIRED AT ALL EXTERIOR WALLS AND OVER SHEARWALLS - NOT REQUIRED AT INTERIOR NON-SHEARWALLS. (30) 16d (24) 16dLESS THAN 20' OVER 20' 4'-0" 6'-0" LENGTH OF WALL (BETWEEN CORNERS)SPLICE LENGTH NAILS ALONGSPLICE LENGTH MINIMUM SPLICE LENGTH PER SCHEDULE T12 ELEVATION - TYPICAL TOP PLATE SPLICE TD24 NO SCALE 4 5 1 3 2 3 2 T10 PLAN VIEW - HOLDOWN LOCATIONS/SHEARWALL END POSTS, "HD" TYPE HOLDOWNS USING SCREWS TD16 NO SCALE NOTE: A.ALL CONDITIONS MAY NOT BE SHOWN. FOR CONDITIONS NOT SHOWN, USE THESE DETAILS AS A GUIDE. B.SOME LARGER HOLDOWNS REQUIRE 6x6 POSTS, SEE PLANS AND SCHEDULES. C.WHERE MULTIPLE TRIMMER STUDS OR KING STUDS OCCUR, MAKE ADJUSTMENTS AS REQUIRED. KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.SHEARWALL SHEATHING, SEE PLAN 3.EDGE OF FOUNDATION 4.SIMPSON HD TYPE HOLDOWN WITH SCREWS 5.SHEARWALL END POST (2 STUDS) TYPICAL, EXCEPT AT HDU11, AND HDU14 WHERE 6x6 POST IS REQUIRED 6.25) - SIMPSON SDS 14"x6" LONG WOOD SCREWS, STAGGERED 7.SHEARWALL EDGE NAILING 8.TRIMMER STUD TO SUPPORT HEADER 9.BLOCK TO SUPPORT WINDOW SILL 10.BUILT UP WOOD POST (2) SHEARWALLS (1) "HD" HOLDOWN W/SCREWS "HD" HOLDOWN W/SCREWS WINDOW JAMB X "HD" HOLDOWN W/SCREWS DOOR JAMB OR WALL END X HOLDOWN X HD19 2-1/8" 1-5/16"HDU2, HDU4, HDU5 HTT4 HTT5 1-5/16" (2) SHEARWALLS (1) "HD" HOLDOWN W/SCREWS AT EXTERIOR CORNER X (1) SHEARWALL (1) "HD" HOLDOWN W/SCREWS AT EXTERIOR CORNER X AT RE-ENTRANT CORNER X (1) SHEARWALL (1) "HD" HOLDOWN W/SCREWS AT RE-ENTRANT CORNER X 4 WINDOW OPENING DOOR OPENING HDU14 1-9/16" LTT20B LTT19 1-3/8" 1-1/2" HDU8, HDU11 1-3/8" 3 2 7 4 1 3 2 7 7 2 1 981 3 4 4 8 3 1 4 7 2 3 6 3 2 77 32 410 5 5 5 5 5 5 5 3 3 1 2 7 2 7 3 6 1 T11 ELEVATION-TYPICAL 1-STORY SHEARWALL TD19 NO SCALE KEYNOTES: 1.SHEATHING MATERIAL 2.DOUBLE STUDS AT EACH END OF SHEARWALL, EDGE NAIL ALONG DOUBLE STUDS 3.FULL HEIGHT WOOD STUDS 4.BOTTOM PLATE ATTACHMENT 5.SIMPSON STHD TYPE HOLDOWN 6.MIDHEIGHT BLOCKING AND EDGE NAILING REQUIRED 7.SIMPSON "PHD" TYPE HOLDOWN 8.FINISHED FLOOR 9.CONT 2x PT SOLE PLATE 1 3 6 8 7 4 5 2 9 2 6 34 1 5 2 1 74 2 1 3 4 18 AT BEAM AT MID WALL AT TOP PLATE T14 TYPICAL BEAM POCKET TD26 NO SCALE KEYNOTES: 1.WOOD BEAM 2.(2) 16d NAILS AT 2" O.C. 3.KING STUD EACH SIDE OF BEAM 4.SOLID BUILT-UP POST BELOW BEAM 5.STRAP BROKEN TOP PLATE ON SIDE OR TOP 6.CONT DBL 2x TOP PLATE W/ LAP SPLICE PER TYPICAL DETAIL 7.FULL-HEIGHT KING STUD EACH SIDE OF BEAM 8.HGA10 CLIP EACH SIDE 9.FULL-HEIGHT KING STUD AT END OF BEAM 10.FULL-HEIGHT KING STUD, OPPOSITE SIDE OF THE BEAM 2 1 4 AT CORNER 10 9 2 KEYNOTES: 1.SHEAR PLATE TO EQUAL OR EXCEED BEAM WEB THICKNESS 3 8" MIN OR AS SHOWN OTHERWISE 2.5 16" FOR 21" DEEP BEAMS OR LESS, 3 8" FOR BEAMS 24" OR GREATER 3.12" CLEAR TO FACE OF SUPPORTING MEMBER (TYP) 4.AISC MIN EDGE DISTANCE 5.HORIZONTAL SHORT SLOTTED HOLES AT 3" O.C. MIN IN EITHER BEAM OR SHEAR PLATE PER AISC SPEC NOTE: A.TYP CONNECTION CONSISTS OF ONE SHEAR PLATE WITH 3 4"Ø OR 7 8"Ø A325N BOLTS, SEE SCHEDULE B.MAINTAIN BOLT SPACING AND EDGE DISTANCES PER AISC SPEC 3 4 4 5 4 1 2 2 1 2" MAX " D " 3 4 4 5 4 2 2 NOMINAL BEAM DEPTH "D"NUMBER OF BOLTS IN ROW UP TO 7"(2) 3 4"Ø 8" TO 10"(2) 3 4"Ø 12" TO 14"(3) 3 4"Ø 16"(4) 3 4"Ø 18"(5) 3 4"Ø 21"(6) 3 4"Ø 24" TO 27"(7) 7 8"Ø 30"(8) 7 8"Ø 33"(9) 7 8"Ø 36"(10) 7 8"Ø T9 TYPICAL SHEAR PLATE CONNECTION DETAIL TD42 NO SCALE PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 5/ 1 8 / 2 3 14 1 3 4 D VID B . P O R T E R L I C E N SED PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 St r u c t u r a l E n g i n e e r i n g fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 co n t a c t @ f r o s t s t r u c t u r a l . c o m S1.1 5/18/23 CE D A R P O I N T S T O R A G E M E T A L B U I L D I N G TI T A N S T E E L RM S DB P IF 2 3 - 0 7 0 TY P I C A L D E T A I L S 32 0 2 W 5 0 0 0 S RE X B U R G , I D A H O 8 3 4 4 0 . . . . . . . . . . . . . . . . . . . . . . NOTE: A.MINIMUM STAPLING SPECIFIED HEREIN SHALL BE PROVIDED UNLESS NOTED OTHERWISE ON PLANS, DETAILS OR GENERAL STRUCTURAL NOTES 8d COMMON AT 12" O.C. 16 GA STAPLE AT 12" O.C. ALTERNATE FASTENER SCHEDULE ALTERNATE FASTENERSPECIFIED FASTENER 8d COMMON AT 6" O.C. 8d COMMON AT 4" O.C. 15 GA STAPLE AT 12" O.C. 14 GA STAPLE AT 12" O.C. 13 GA STAPLE AT 12" O.C. 16 GA STAPLE AT 4" O.C. 15 GA STAPLE AT 5" O.C. 14 GA STAPLE AT 6" O.C. 13 GA STAPLE AT 6" O.C. 13 GA STAPLE AT 5" O.C. 14 GA STAPLE AT 4" O.C. 15 GA STAPLE AT 3" O.C. 16 GA STAPLE AT 2.5" O.C. 15 GA STAPLE AT 2" O.C. 14 GA STAPLE AT 3" O.C. 13 GA STAPLE AT 4" O.C. 8d COMMON AT 3" O.C. MATERIAL: 7/16" SHEARWALL OR ROOF SHEATHING NOTES: 1.STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 716" INCH OUTSIDE DIMENSION. AND INSTALLED WITH CROWN PARALLEL TO THE LONG DIMENSION OF FRAMING MEMBER. 2.FRAMING SHALL BE 3x OR WIDER WHEN NAIL SPACING IS LESS THAN 3 INCHES ON CENTER. 3.ALL STAPLES SHALL HAVE 112" LONG LEGS MINIMUM. 4.STAPLE SIZES AND SPACING PER REPORT NO. ICC-ESR-1539 T15 ALTERNATE SHEATHING STAPLE OPTION TD32 NO SCALE CONNECTION TYPE JOIST OR TRUSS BEARING ON SILL OR GIRDER BRIDGING TO JOIST SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL TOP PLATE TO STUD DOUBLE STUDS, FACE NAIL DOUBLE TOP PLATES CONTINUOUS HEADER TO STUD CEILING JOISTS, LAPS OVER PARTITIONS CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL RAFTER OR TRUSS TO PLATE BUILT-UP CORNER STUDS TOENAIL (4)-8d COMMON (2 1/2" x 0.131") NAILING (3)-8d COMMON (2 1/2" x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES TOENAIL EACH END(2)-3"x 0.131" NAILS (Gun Nail) (2)-3"x 14 GAUGE STAPLES 16d (3 1/2"x 0.135") AT 16" O.C. FACE NAIL 3"x 14 GAUGE STAPLES AT 12" O.C. 3"x 0.131" NAILS (Gun Nail) AT 8" O.C. END NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES SOLE PLATE TO STUD END NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES FACE NAIL 16d (3 1/2"x 0.135") AT 24" O.C. 3"x 14 GAUGE STAPLES AT 8" O.C. 3"x 0.131" NAILS (Gun Nail) AT 8" O.C. FACE NAIL 16d (3 1/2"x 0.135") AT 16" O.C. 3"x 14 GAUGE STAPLES AT 12" O.C. 3"x 0.131" NAILS (Gun Nail) AT 12" O.C. DOUBLE TOP PLATES - FACE NAIL (8)-16d COMMON (3 1/2"x 0.162") (12)-3"x 0.131" NAILS (Gun Nail) (12)-3"x 14 GAUGE STAPLES LAP SPLICE RIM JOIST TO TOP PLATE 8d (2 1/2"x 0.131") AT 6" O.C. 3"x 14 GAUGE STAPLES AT 6" O.C. 3"x 0.131" NAILS (Gun Nail) AT 6" O.C. BLOCKING BETWEEN JOISTS OR RAFTERS TOENAIL (3)-8d COMMON (2 1/2"x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES AND TOP PLATE TOENAIL TOP PLATES, LAPS AND INTERSECTIONS FACE NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES CONTINUOUS HEADER, TWO PIECES 16d COMMON (3 1/2"x 0.162") FACE NAIL AT 16" O.C. ALONG EDGES CEILING JOISTS TO PLATE TOENAIL (3)-8d COMMON (2 1/2"x 0.131") (5)-3"x 0.131" NAILS (Gun Nail) (5)-3"x 14 GAUGE STAPLES FACE NAIL (3)-16d COMMON (3 1/2"x 0.162) (4)-3"x 0.131" NAILS (Gun Nail) (4)-3"x 14 GAUGE STAPLES (3)-16d COMMON (3 1/2"x 0.162) (4)-3"x 0.131" NAILS (Gun Nail) (4)-3"x 14 GAUGE STAPLES FACE NAIL (3)-8d COMMON (2 1/2"x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES TOENAIL TOENAIL 16d COM.(3 1/2"x 0.162") AT 24" O.C. 3"x 14 GAUGE STAPLES AT 16" O.C. 3"x 0.131" NAILS (Gun Nail) AT 16" O.C.FACE NAIL (2)-8d COMMON (2 1/2" x 0.131") USE- SIMPSON A35 AT 48" O.C.-NA- SIMPSON A35 AT EVERY OTHER BLOCK -NA- NOTE: A.MINIMUM NAILING SPECIFIED HEREIN SHALL BE PROVIDED UNLESS NOTED OTHERWISE ON PLANS, DETAILS OR GENERAL STRUCTURAL NOTES B.NAILING NOT NOTED ON THESE PLANS OR DETAILS SHALL BE PER I.B.C. TABLE 2304.10.1 T16 MINIMUM NAILING SCHEDULE - UNLESS NOTED OTHERWISE TD34 NO SCALE KEYNOTES: 1.WOOD I-JOIST, SEE PLAN 2.BEARING LOCATION, SEE PLAN 3.FLOOR / ROOF SHEATHING W/ ATTACHMENT, SEE PLAN 4.CONT RIM BOARD W/ ATTACHMENT, SEE CORRESPONDING DETAILS 5.WEB STIFFENERS AS REQUIRED, SEE PLAN / CORRESPONDING DETAILS. WHEN WEB STIFFENERS ARE REQUIRED, PLACE ON EACH SIDE OF WEB UNO 6.212" MIN WEB STIFFENER WIDTH 7.GAP BETWEEN TOP OF WEB STIFFENER AND BOTTOM OF TOP FLANGE OF WOOD JOIST MIN GAP = 18" MAX GAP = 2" 8.WEB STIFFENER TO FIT TIGHT AGAINST FLANGE OF WOOD I-JOIST 9.I-JOIST FLANGE WIDTH 10.WEB STIFFENER THICKNESS PER SCHEDULE 11.(3) ROWS CLINCHED FASTENERS. FOR FLANGE WIDTHS 13 4" - 25 16", USE 8d (0.113"x212") FASTENERS AND FOR 312" FLANGE WIDTHS, USE 16d (0.135"x312") FASTENERS 12.1" SPACE FOR FLANGE WIDTHS 13 4" - 25 16" AND 112" SPACE FOR 312" FLANGE WIDTH 13.BEVELED WEB STIFFENERS AS REQUIRED, SEE PLAN / COORESPONDING DETAILS. WHEN WEB STIFFENERS ARE REQUIRED, PLACE ON EACH SIDE OF WEB UNO 14.CONT SHAPED BEARING PLATE. SEE COORESPONDING DETAILS 15.I-JOIST HANGER, SEE PLAN 16.WEB STIFFENERS REQUIRED WHERE HANGER SIDES DO NOT EXTEND TO LATERALLY SUPPORT 3 8" MIN OF TOP FLANGE OF I-JOIST OR AS SPECIFIED, SEE PLAN / CORRESPONDING DETAILS. WHEN WEB STIFFENERS ARE REQUIRED, PLACE ON EACH SIDE OF WEB 17.CONCENTRATED LOAD IN CLR SPAN OF JOIST, SEE PLANS AND DETAILS FOR ADDITIONAL INFORMATION T17 TYPICAL WEB STIFFENER REQUIREMENTS TD76 NO SCALE 2 1 3 6 5 7 8 4 7 5 7 5 8 1 WEB STIFFENER THICKNESS SCHEDULE: FLANGE WIDTH:WEB STIFFENER THICKNESS: 13 4"5 8" 2116"3 4" 25 16"7 8" 312"2x4 DF NO.2 OR BETTER (ORIENTED VERTICAL) 9 1010 8 11 SECTION ELEVATION 12 12 1 2 3 12 3 ELEVATION 5 8 7 6 5 8 14 ELEVATION ELEVATION 2 3 1 8 7 16 15 6 7 ELEVATION 1 3 17 5 8 7 PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 5/ 1 8 / 2 3 14 1 3 4 D VID B . P O R T E R L I C E N SED PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 St r u c t u r a l E n g i n e e r i n g fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 co n t a c t @ f r o s t s t r u c t u r a l . c o m S1.2 5/18/23 CE D A R P O I N T S T O R A G E M E T A L B U I L D I N G TI T A N S T E E L RM S DB P IF 2 3 - 0 7 0 TY P I C A L D E T A I L S 32 0 2 W 5 0 0 0 S RE X B U R G , I D A H O 8 3 4 4 0 . . . . . . . . . . . . . . . . . . . . . . 4" CONCRETE SLAB ON GRADE W/ #3 AT 24" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME FINISH FLOOR = 100'-0" CONCRETE SLAB ON GRADE F42 F54 F36 F48 1 A T.O.F. 98'-0" 1 WF16 / W1 WF16 / W1 WF 1 6 / W 1 WF 1 6 / W 1 2 F B D E 2 3 4 5 6 A C D F E 4 5 6 1 2 3 WF16 / W1 WF 1 6 / W 1 1'-0" 1'-0"1'-0" 1'-0" 1'-0"1'-0" 55'-0" 27'-6"27'-6" 2' - 3 " 3' - 4 1 2" 6" 22 ' - 6 " 45 ' - 0 " 22 ' - 6 " 3' - 0 " 18 ' - 0 " 2' - 0 " 22 ' - 0 " 45 ' - 0 " 23 ' - 0 " 27'-6" 115'-0" 27'-6"20'-0"20'-0"20'-0" 20'-0"20'-0"20'-0" 60'-0" 2' - 6 " 18 ' - 0 " 3' - 0 " 22 ' - 6 " 22 ' - 6 " 90 ' - 0 " 22 ' - 6 " 22 ' - 6 " 1 1 T.O.F. 98'-0" T.O.W. 102'-0" F48 F72 F108 F48 F60 F54 F42 F84 F96 F60 F54 SC1 F54 SC1 F72A SC1 F72A SC1 F72A SC1 F72A SC1 F72A SC1 F72A SC1 F54 F108 SC1 F72 13'-9"13'-9"13'-9"13'-9" F42A F42AF42AF42A F42A 10'-0"10'-0"10'-0"10'-0"10'-0" T.O.W. 102'-0" 4 60° TYP SC1 F54 WF18 A SC1 F72A A SC1 SC1 3 60° TYP F96 3 2 6 0 ° T Y P 2 60° TYP 2 A 2 6 0 ° T Y P WF 1 8 A 16 ' - 1 0 1 2" WF18 F84 SC1 F54 SC1 SC1 F54A WF18 2 A 2 6 0 ° T Y P A WF 1 8 WF 1 8 2 1 16 ' - 7 1 2" 3' - 4 1 2" 2' - 0 " 11 6'-0"3'-41 2"10'-71 2"2'-0"16'-0"2'-0" 1 18 ' - 0 " 2' - 0 " 1 1 1 3' - 0 " 10 ' - 0 " 2' - 0 " 3' - 4 1 2" 4' - 1 1 2" 1' - 6 " 2'-6"3'-41 2"21'-71 2" 4 SC1 F54A SC1 F54 SC1 F54 WF18 10" 10" 5 5 55 55 5 TYP 101 TYP 101 110 102 102 103 105 104 OPP 103 OPP 103 TYP 110 TYP 110 TYP 110 TYP 101 102 103 103 103 105 105 103 105 104 109104 104 104 108 108 108 104 TYP 106 112 TYP 111 108108 108 112 102 102102 102 102 102 102 107 SCALE: FOUNDATION PLAN 3/16" = 1'-0" PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 5/ 1 8 / 2 3 14 1 3 4 D VID B . P O R T E R L I C E N SED HEADED ANCHOR ROD EMBED SCHEDULE DIAMETER MINIMUM EMBEDMENT (FROM TOP OF PIER/WALL) 1 2"12" 5 8"14" 3 4"16" 7 8"18" 1"20" 11 4"25" WALL (W) SCHEDULE MARK THICKNESS AND TYPE VERTICAL REINFORCING HORIZONTAL REINFORCING REMARKS W1 8" CONCRETE #4 AT 18" O.C.#4 AT 18" O.C.--- PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 St r u c t u r a l E n g i n e e r i n g fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 co n t a c t @ f r o s t s t r u c t u r a l . c o m S2.0 5/18/23 CE D A R P O I N T S T O R A G E M E T A L B U I L D I N G TI T A N S T E E L RM S DB P IF 2 3 - 0 7 0 FO U N D A T I O N P L A N 32 0 2 W 5 0 0 0 S RE X B U R G , I D A H O 8 3 4 4 0 . . . . . . . . . . . . . . . . . . . . . . A.VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B.ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C.THE DEPTH OF FOOTING DIMENSION INDICATED IN THE G.S.N. IS A MINIMUM. FOUNDATION CONTRACTOR SHALL COORDINATE WITH THE SOILS REPORT AND OTHER TRADES TO INSURE THAT THESE MINIMUMS ARE SUFFICIENT FOR THE WORK. SEE TYPICAL DETAILS FOR ADDITIONAL REQUIREMENTS. D.W1, W2, ETC. - AS SHOWN ON PLAN INDICATES CONCRETE OR MASONRY WALLS. SEE WALL SCHEDULE FOR ADDITIONAL INFORMATION. E.WF18, WF24, ETC. - AS SHOWN ON PLAN INDICATES A CONTINUOUS WALL FOOTING. SEE WALL FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. F.F36, F48, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. G. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. H. , , - AS SHOWN ON PLAN INDICATES A SHEARWALL HOLDOWN. SEE HOLDOWN SCHEDULES AND DETAILS FOR ADDITIONAL INFORMATION. FOUNDATION PLAN NOTES 5 6.7 A B 1.VERIFY DOOR OPENING W/ METAL BUILDING MANUFACTURER DRAWINGS. 2.(1) #4x20'-0" LONG (10'-0" EACH LEG) HAIRPIN. 3.(1) #6x30'-0" LONG (15'-0" EACH LEG) HAIRPIN. 4.PROVIDE 22"Ø CONCRETE PIER W/ (12) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER BELOW PORTAL FRAME COLUMN, SIM TO DETAIL 104. PLAN KEYNOTESX FOOTING SCHEDULE NOTES: 1. FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. 2. FOR MINIMUM CLEARANCE (CLR) OF REINFORCING, SEE GENERAL STRUCTURAL NOTES (GSN). MARK LENGTH WIDTH THICKNE SS FOOTING REINFORCING REMARKS F36 36"36"10"(4) #4 EACH WAY TOP AND BOTTOM --- F42 42"42"10"(5) #4 EACH WAY TOP AND BOTTOM --- F42A 42"42"10"(5) #4 EACH WAY BOTTOM --- F48 48"48"10"(6) #4 EACH WAY TOP AND BOTTOM --- F54 54"54"12"(7) #4 EACH WAY TOP AND BOTTOM --- F54A 54"54"12"(7) #4 EACH WAY BOTTOM --- F60 60"60"12"(6) #5 EACH WAY TOP AND BOTTOM --- F72 72"72"12"(7) #5 EACH WAY TOP AND BOTTOM --- F72A 72"72"12"(7) #5 EACH WAY BOTTOM --- F84 84"84"12"(8) #5 EACH WAY TOP AND BOTTOM --- F96 96"96"14"(10) #5 EACH WAY TOP AND BOTTOM --- F108 108"108"14"(11) #5 EACH WAY TOP AND BOTTOM --- WF10 CONT 10"8"(2) #4 CONT BOTTOM WF16 CONT 16"10"(2) #4 CONT BOTTOM MONO POUR W/ SLAB STRIP FOOTING STEEL COLUMN (SC) SCHEDULE MARK SIZE BASE CONNECTION SC1 HSS6x6x14 SEE DETAIL SHEARWALL HOLDOWN SCHEDULE NOTES: 1. SEE TYPICAL DETAILS FOR ANCHOR BOLT EMBEDMENT REQUIREMENTS. 2. POSTS SHOWN ON THE PLANS AR A MINIMUM AS REQUIRED TO SUPPORT THE GRAVITY LOADS OF THE STRUCTURE. ADDITIONAL STUDS OR SOLID POSTS MAY BE REQUIRED DEPENDENT ON HOLDOWN TYPES. MARK HOLDOWN SHEARWALL END POST UNO ON PLAN ALTERNATE HOLDOWN ANCHOR BOLT DIA. SIMPSON HTT4 W/ (18) 0.162x2.5" NAILS (2) 2x STUDS N/A 5 8"A SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 5 7,360.59 sf P1 1 A F B D E 2 3 4 5 6 A C D F E 4 5 6 1 2 3 OPEN WJ 1 TYPICAL FLOOR SHEATHING: 3/4" APA RATED FLOOR SHEATHING W/ 10d COMMON NAILS AT 6" O.C. AT PANEL EDGES / BOUNDARY AND AT 12" O.C. IN THE FIELD. B4 W1 0 x 8 8 O R W 1 6 x 4 0 W1 0 x 8 8 O R W 1 6 x 4 0 W1 0 x 8 8 O R W 1 6 x 4 0 W1 0 x 8 8 O R W 1 6 x 4 0 W1 0 x 8 8 O R W 1 6 x 4 0 W1 0 x 8 8 O R W 1 6 x 4 0 W1 0 x 8 8 O R W 1 6 x 4 0 W1 0 x 8 8 O R W 1 6 x 4 0 W1 0 x 8 8 O R W 1 6 x 4 0 W1 0 x 8 8 O R W 1 6 x 4 0 W1 0 x 8 8 O R W 1 6 x 4 0 W1 0 x 8 8 O R W 1 6 x 4 0 B2 WJ 2 WJ 1 WJ 1 FUTURE MEZZANINE 5 5 55 55 B2 B2 B2 B3 B3 B3 WJ 1 WJ 1 B3 B2 B4 B1 OPEN WJ 1 P1 B3 (3) KS P2 (3) KS P2 (3) KS P2 (3) KS P2 W1 0 x 8 8 O R W 1 6 x 4 0 B3 B3 OPEN 1 TYP 208 202 TYP 204 TYP 208 203 TYP 208 205 TYP 204 TYP 204 TYP 204 201 201 TYP 208202 TYP 207 205 203 206 209 TYP 207 WJ 1 WJ 2 WJ 1 WJ 1 209 2 1 3 3 311 5 P1 B3 B3 209 P1 2 B3 B3 P1 2 2222 210 P1 P1 P1 SCALE: MEZZANINE FRAMING PLAN 3/16" = 1'-0" PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 5/ 1 8 / 2 3 14 1 3 4 D VID B . P O R T E R L I C E N SED PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 St r u c t u r a l E n g i n e e r i n g fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 co n t a c t @ f r o s t s t r u c t u r a l . c o m S2.1 5/18/23 CE D A R P O I N T S T O R A G E M E T A L B U I L D I N G TI T A N S T E E L RM S DB P IF 2 3 - 0 7 0 ME Z Z A N I N E F R A M I N G P L A N 32 0 2 W 5 0 0 0 S RE X B U R G , I D A H O 8 3 4 4 0 . . . . . . . . . . . . . . . . . . . . . . FLOOR FRAMING PLAN NOTES A.VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B.ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C.IF DOUBLE TOP PLATE IS NOTCHED, STEPPED OR BROKEN, PROVIDE A SIMPSON MSTC40 STRAP AT DISCONTINUITY. D.TYPICAL BEARING WALL FRAMING SHALL BE 2x6 STUDS AT 16" O.C. UNO. E.PROVIDE TRIMMER STUDS (TS) AND KING STUDS (KS) AT OPENINGS AS NOTED ON THE PLANS. FOR ATTACHMENT, SEE "TYPICAL HEADER CONNECTION" DETAIL. F. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. G. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. H. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. I.B1, B2, ETC. - AS SHOWN ON PLAN INDICATES A BEAM OR HEADER. SEE BEAM SCHEDULE FOR ADDITIONAL INFORMATION. J.WJ1, WJ2, ETC. - AS SHOWN ON PLAN INDICATES A WOOD JOIST. SEE WOOD JOIST SCHEDULE FOR ADDITIONAL INFORMATION. K.P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. L.FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING CONDITION. 5 6.7 1.ATTACH BEAM TO NAILER W/ MIT411.88 HANGER (TYPICAL). 2.ATTACH BEAM TO COLUMN W/ HUC410 HANGER, WELD HANGER TO COLUMN PER MANUFACTURER. 3.ATTACH BEAM W/ LUS410 HANGER PLAN KEYNOTESX BEAM (B) SCHEDULE MARK SIZE B1 (2) 2x6 B2 (2) 2x8 B3 (2) 13 4x117 8 LVL B4 518x21 GLB WOOD JOIST ( ) SCHEDULE MARK JOIST FACE MOUNT HANGER TOP FLANGE HANGER WJ1 117 8" TJI 210 AT 16" O.C.IUS2.06/11.88 ITS2.06/11.88 WJ2 117 8" TJI 360 AT 16" O.C.IUS2.37/11.88 ITS2.37/11.88 WJ SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 5 POST (P) SCHEDULE NOTES: 1. FOR CONNECTIONS AT EITHER END OF POST, SEE DETAILS. 2. UNO, SEE GENERAL STRUCTURAL NOTES (GSN) FOR LUMBER SPECIES AND GRADE. MARK SIZE SPECIES AND GRADE CONNECTION P1 (2) 2x6 DOUG FIR NO. 2 SEE TYPICAL DETAILS P2 6x6 DOUG FIR NO. 1 SEE TYPICAL DETAILS KEYNOTES: 1.PRE-ENGINEERED BUILDING BEYOND 2.CONCRETE STEM WALL, SEE PLAN 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE SLAB ON GRADE, SEE PLAN 8.#4 BENT DOWEL AT 18" O.C. 102 PRE-ENGINEERED BUILDING AT CONCRETE FOOTING CS_MB102 NO SCALE 3" CLR 3" CL R 1 5 6 7 8 3 2 3 4 18" 18" KEYNOTES: 1.PRE-ENGINEERED COLUMN, SEE PLAN 2.ANCHOR BOLTS W/ NUT AT BOTTOM 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING AND CONCRETE STEM WALL BEYOND, CONT REINFORCEMENT TROUGH PIER (NOT SHOWN FOR CLARITY) 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE FOOTING, SEE PLAN 8.CONCRETE PIER W/ (6) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 9.CONCRETE SLAB ON GRADE, SEE PLAN 103 PRE-ENGINEERED COLUMN AT CONCRETE FOOTING CS_MB103 NO SCALE 3" CLR 3" CL R 7 6 3 9 3" MIN 3 1 2 8 5 4 KEYNOTES: 1.PRE-ENGINEERED COLUMN, SEE PLAN 2.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3.CONCRETE STEM WALL BEYOND, CONT REINFORCEMENT TROUGH PIER (NOT SHOWN FOR CLARITY) 4.MINIMUM FOOTING DEPTH, SEE GSN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 6.CONCRETE FOOTING, SEE PLAN 7.18"Ø CONCRETE PIER W/ (8) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 8.ANCHOR BOLTS W/ NUT AT BOTTOM 9.HAIRPIN AS OCCURS, SEE PLAN 10.CONCRETE SLAB ON GRADE, SEE PLAN 104 PRE-ENGINEERED COLUMN AT CONCRETE FOOTING NO SCALE 5 3 10 9 7 4 1 8 6 22 3" CLR 3" CL R 105 PRE-ENGINEERED COLUMN AT CONCRETE FOOTING CS_MB118 NO SCALE KEYNOTES: 1.PRE-ENGINEERED COLUMN, SEE PLAN 2.ANCHOR BOLTS W/ NUT AT BOTTOM 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING & CONCRETE STEM WALL BEYOND CONT REINFORCING THROUGH PIER (NOT SHOWN FOR CLARITY) 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE FOOTING, SEE PLAN 8.CONCRETE PIER W/ (6) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 9.CONCRETE SLAB ON GRADE, SEE PLAN 10.HAIRPIN AS OCCURS, SEE PLAN 3" CLR 3" CL R 3" MIN 7 6 3 10 3 1 2 8 9 4 5 KEYNOTES: 1.PRE-ENGINEERED BUILDING 2.CONCRETE STEM WALL, SEE PLAN 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE SLAB ON GRADE, SEE PLAN 101 PRE-ENGINEERED BUILDING AT CONCRETE FOOTING CS_MB101 NO SCALE 3" CLR 3" CL R 1 5 6 7 33 2 4 106 TYPICAL STEEL COLUMN AT FOUNDATION NO SCALE 1 2 3 5 1 KEYNOTES: 1.STEEL COLUMN, SEE PLAN 2.CONCRETE FOOTING, SEE PLAN 3.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 4.CONCRETE CLOSURE POUR, POUR AFTER DEAD LOADS ARE IN PLACE 5.CONCRETE SLAB ON GRADE, SEE PLAN 6.STEEL BASEPLATE W/ (4) 3 4"Ø ANCHOR BOLTS W/ 9" MIN EMBEDMENT 4 4 PLANA A 3" CLR 3" CL R 107 STEEL COLUMN AT FOUNDATION NO SCALE 1 2 3 5 1 KEYNOTES: 1.PRE-ENGINEERED COLUMN, SEE PLAN 2.CONCRETE FOOTING, SEE PLAN 3.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 4.CONCRETE CLOSURE POUR, POUR AFTER DEAD LOADS ARE IN PLACE 5.CONCRETE SLAB ON GRADE, SEE PLAN 6.THICKEN FOOTING AS REQUIRED FOR ANCHOR BOLT EMBEDMENT 7.STEEL COLUMN, SEE PLAN 8.STEEL BASEPLATE W/ (4) 3 4"Ø ANCHOR BOLTS W/ 9" MIN EMBEDMENT 4 4 PLANA A 3" CLR 3" CL R 6 KEYNOTES: 1.PRE-ENGINEERED COLUMN, SEE PLAN 2.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3.CONCRETE STEM WALL BEYOND, CONT REINFORCEMENT TROUGH PIER (NOT SHOWN FOR CLARITY) 4.MINIMUM FOOTING DEPTH, SEE GSN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 6.CONCRETE FOOTING, SEE PLAN 7.26"x14" CONCRETE PIER W/ (10) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 8.ANCHOR BOLTS W/ NUT AT BOTTOM 9.HAIRPIN AS OCCURS, SEE PLAN 10.CONCRETE SLAB ON GRADE, SEE PLAN 11.STEEL COLUMN, SEE PLAN 12.STEEL BASEPLATE W/ (4) 3 4"Ø ANCHOR BOLTS W/ 9" MIN EMBEDMENT 109 PRE-ENGINEERED COLUMN AT CONCRETE FOOTING NO SCALE 5 3 10 9 7 4 1 8 6 22 3" CLR 3" CL R KEYNOTES: 1.PRE-ENGINEERED BUILDING BY OTHERS 2.CONCRETE STEM WALL, SEE PLAN 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE SLAB ON GRADE, SEE PLAN 8.CONT 2x PT SOLE PLATE W/ SIMPSON STRONG BOLT 2 (ESR-3037) HILTI ANCHORS KWIK-BOLT TZ (ESR-1917) OR SIMILAR APPROVED PRODUCT, SEE SHEARWALL SCHEDULE FOR SIZE AND SPACING 9.WALL SHEATHING AS OCCURS, SEE PLAN 10.WOOD STUD WALL, SEE PLAN 1 33 2 7 5 10 9 8 4" MI N 3" CLR 3" CL R 6 5 4 110 PRE-ENGINEERED BUILDING AT CONCRETE FOUNDATION NO SCALE 112 WOOD STUD WALL AT FOUNDATION NO SCALE KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ O.145"Ø MIN SHOT PIN AT 32" O.C. 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE FOOTING, SEE PLAN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN NOTES: A.CONTINUOUS FOOTING CAN BE POURED MONOLITHICALLY W/ SLAB AT CONTRACTORS OPTION 3" CLR 3" CL R 5 1 2 4 3 3" CLR 3" CL R 5 1 2 4 3 A OPTION B OPTION 11 2" TYP 112" TY P TYP 1/4 6 2" 112" TY P TYP1/4 8 7 7 7 11 12 KEYNOTES: 1.STEEL COLUMN, SEE PLAN 2.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3.CONCRETE STEM WALL BEYOND, CONT REINFORCEMENT TROUGH PIER (NOT SHOWN FOR CLARITY) 4.MINIMUM FOOTING DEPTH, SEE GSN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 6.CONCRETE FOOTING, SEE PLAN 7.18"Ø CONCRETE PIER W/ (8) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 8.CONCRETE SLAB ON GRADE, SEE PLAN 9.STEEL BASEPLATE W/ (4) 3 4"Ø ANCHOR BOLTS W/ 9" MIN EMBEDMENT 108 PRE-ENGINEERED COLUMN AT CONCRETE FOOTING NO SCALE 5 3 8 7 4 1 9 6 22 3" CLR 3" CL R 112" TY P 112" TY P 111 PRE-ENGINEERED BUILDING AT CONCRETE FOOTING NO SCALE KEYNOTES: 1.PRE-ENGINEERED BUILDING BY OTHERS 2.CONCRETE STEM WALL, SEE PLAN 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE SLAB ON GRADE, SEE PLAN 8.CONT 2x PT SOLE PLATE W/ ANCHOR BOLTS PER SHEARWALL SCHEDULE 9.WALL SHEATHING AS OCCURS, SEE PLAN 10.WOOD STUD WALL, SEE PLAN 11.EDGE NAILING, SEE SHEARWALL SCHEDULE 12.SIMPSON HOLDOWN, SEE PLAN 13.5 8"Ø ALL THREAD, DRILL AND EPOXY 7" EMBEDMENT 14.(3) #4x18" LONG EPOXY DOWELS AT HOLDOWN ANCHORS W/ 5" MINIMUM EMBEDMENT 3" CLR 3" CL R 4 1 5 6 33 2 7 5 10 9 8 12 13 11 14 3"2" 2" 112" TY P TYP1/4 112" TY P 3"2" 2" 112" TY P TYP1/4 112" TY P 3"2" PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 5/ 1 8 / 2 3 14 1 3 4 D VID B . P O R T E R L I C E N SED PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 St r u c t u r a l E n g i n e e r i n g fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 co n t a c t @ f r o s t s t r u c t u r a l . c o m S3.0 5/18/23 CE D A R P O I N T S T O R A G E M E T A L B U I L D I N G TI T A N S T E E L RM S DB P IF 2 3 - 0 7 0 FO U N D A T I O N D E T A I L S 32 0 2 W 5 0 0 0 S RE X B U R G , I D A H O 8 3 4 4 0 . . . . . . . . . . . . . . . . . . . . . . KEYNOTES: 1.WOOD JOIST W/ (2) 16d NAILS, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.WALL SHEATHING AS OCCURS, SEE PLAN 5.EDGE NAILING, SEE SHEARWALL SCHEDULE 6.CONT RIM BOARD 7.BOUNDARY NAILING, SEE PLAN 8.A35 CLIP BETWEEN EVERYOTHER JOIST 9.FLOOR SHEATHING, SEE PLAN 10.PRE-ENGINEERED BUILDING 11.WOOD JOIST WEB STIFFENER EACH SIDE OF JOIST, SEE TYPICAL DETAIL 1 2 3 5 4 7 6 9 10 8 201 WOOD JOIST AT WOOD STUD WALL NO SCALE KEYNOTES: 1.WOOD JOIST, SEE PLAN 2.WOOD JOIST BLOCKING AT 24" O.C. W/ (2) 16d NAILS 3.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 4.WOOD STUD WALL, SEE PLAN 5.WALL SHEATHING AS OCCURS, SEE PLAN 6.EDGE NAILING, SEE SHEARWALL SCHEDULE 7.CONT RIM BOARD W/ A35 CLIP AT 32" O.C. 8.BOUNDARY NAILING, SEE PLAN 9.FLOOR SHEATHING, SEE PLAN 10.(4) 10d NAILS INTO EACH BLOCK 11.PRE-ENGINEERED BUILDING 202 WOOD JOIST AT WOOD STUD WALL NO SCALE 1 3 4 6 5 8 7 9 2 10 204 WOOD JOIST AT STEEL BEAM NO SCALE KEYNOTES: 1.WOOD JOIST W/ HANGER, SEE PLAN 2.STEEL BEAM, SEE PLAN 3.CONT 2x NAILER W/ 5 8"Ø THREADED STUDS W/ WASHER AT 32" O.C. (COUNTER SINK AS REQUIRED) 4.FLOOR SHEATHING, SEE PLAN 5.BOUNDARY NAILING, SEE PLAN 6.WOOD JOIST WEB STIFFENER EACH SIDE OF JOIST, SEE TYPICAL DETAIL 1 4 12 3 5 KEYNOTES: 1.WOOD JOIST W/ HANGER, SEE PLAN 2.WOOD BEAM, SEE PLAN 3.BOUNDARY NAILING, SEE PLAN 4.FLOOR SHEATHING, SEE PLAN 1 34 2 206 WOOD JOIST AT WOOD BEAM NO SCALE KEYNOTES: 1.STEEL BEAM, SEE PLAN 2.14" THICK STEEL CAP PLATE 3.STEEL BEAM SHEAR PLATE, SEE TYPICAL SHEAR PLATE CONNECTION DETAIL 4.STEEL COLUMN, SEE PLAN 1 21 4 3 3 207 STEEL BEAM AT STEEL COLUMN NO SCALE NOTES: A.SEE CORRESPONDING DETAILS FOR ADDITIONAL INFORMATION 208 STEEL BEAM AT STEEL COLUMN NO SCALE KEYNOTES: 1.STEEL BEAM, SEE PLAN 2.STEEL COLUMN, SEE PLAN 3.14" THICK STEEL CAP PLATE 4.STEEL BEAM SHEAR PLATE, SEE TYPICAL SHEAR PLATE CONNECTION DETAIL 1 2 4 3 NOTES: A.SEE CORRESPONDING DETAILS FOR ADDITIONAL INFORMATION 11 KEYNOTES: 1.WOOD JOIST W/ (2) 16d NAILS, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.BOUNDARY NAILING, SEE PLAN 5.FLOOR SHEATHING, SEE PLAN 6.CONT RIM BOARD 7.WOOD JOIST WEB STIFFENER EACH SIDE OF JOIST, SEE TYPICAL DETAIL 1 2 3 4 6 5 203 WOOD JOIST AT WOOD STUD WALL NO SCALE 205 WOOD JOIST AT STEEL BEAM NO SCALE KEYNOTES: 1.WOOD JOIST W/ HANGER, SEE PLAN 2.STEEL BEAM, SEE PLAN 3.CONT 2x NAILER W/ 5 8"Ø THREADED STUDS W/ WASHER AT 32" O.C. (COUNTER SINK AS REQUIRED) 4.FLOOR SHEATHING, SEE PLAN 5.BOUNDARY NAILING, SEE PLAN 6.WOOD JOIST WEB STIFFENER EACH SIDE OF JOIST, SEE TYPICAL DETAIL 1 4 2 3 5 KEYNOTES: 1.STEEL BEAM, SEE PLAN 2.1 4" THICK STEEL CAP PLATE 3.STEEL BEAM SHEAR PLATE, SEE TYPICAL SHEAR PLATE CONNECTION DETAIL 4.STEEL COLUMN, SEE PLAN 1 2 1 4 3 3 209 STEEL BEAM AT STEEL COLUMN NO SCALE NOTES: A.SEE CORRESPONDING DETAILS FOR ADDITIONAL INFORMATION 11 7 6 6 6 9 10 33 4 5 11 8 KEYNOTES: 1.WOOD JOIST, SEE PLAN 2.WOOD BEAM, SEE PLAN 3.EDGE NAILING, SEE SHEARWALL SCHEDULE 4.WALL SHEATHING CONSTRUCTED AS A TYPE "5" SHEARWALL 5.BOUNDARY NAILING, SEE PLAN 6.WOOD STUD WALL, SEE PLAN 7.CONT 2x BOTTOM PLATE, ATTACH PER SHEARWALL SCHEDULE 8.FLOOR SHEATHING, SEE PLAN 9.WOOD JOIST BLOCKING AT 24" O.C. W/ (2) 16d NAILS 10.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 11.CONT RIM BOARD 12.(4) 10d NAILS INTO EACH BLOCK 210 WOOD STUD WALL AT WOOD BEAM NO SCALE 5 6 7 8 2 1 3 1 12 PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 5/ 1 8 / 2 3 14 1 3 4 D VID B . P O R T E R L I C E N SED PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 St r u c t u r a l E n g i n e e r i n g fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 co n t a c t @ f r o s t s t r u c t u r a l . c o m S4.0 5/18/23 CE D A R P O I N T S T O R A G E M E T A L B U I L D I N G TI T A N S T E E L RM S DB P IF 2 3 - 0 7 0 FR A M I N G D E T A I L S 32 0 2 W 5 0 0 0 S RE X B U R G , I D A H O 8 3 4 4 0 . . . . . . . . . . . . . . . . . . . . . .