HomeMy WebLinkAboutCRAPO DUPLEX - 156 E 2nd SINDEX OF SHEETS
G-101
G-102
C-101
A-101
A-102
A-103
A-201
A-301
S-101
COVER SHEET
GENERAL NOTES
SITE
MAIN LEVEL
LOWER LEVEL
DEMOLITION PLAN
ELEVATIONS
SECTIONS
FOUNDATION
INDEX OF SHEETS
S-201
S-301
S-302
S-401
S-402
S-403
R-101
E-101
E-102
FLOOR FRAMING
WALL FRAMING
WALL FRAMING
CEILING FRAMING
ROOF FRAMING RAFTERS
ROOF FRAMING STRUCTURE
DETAILS
MEP MARKUP PLAN
MEP MARKUP PLAN
FINISHED SQUARE FOOTAGE
ID
BASEMENT
MAIN FLOOR
AREA
1,237
1,513
2,750 ft²
UNFINISHED SQUARE FOOTAGE
ID
GARAGE
AREA
241
241 ft²
VICINITY MAP
NOT TO SCALE
6
PROPERTY LOCATION
LOCATION: REXBURG, ID.
ROOF SNOW:
GROUND SNOW:
WIND SPEED:
EXPOSURE: C
FROST DEPTH:
SEISMIC:
Ss
S1
SDS
SD1
REGULATION: IRC 2018
CRAPO DUPLEX REMODEL
43.821429, -111.779089
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
CO
V
E
R
SH
E
E
T
SH
E
E
T
TI
T
L
E
:
G-101
PLN# 247-01-011
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.
STAIRS:
1. (R311.7.1) MIN WIDTH OF 36" WITH MAX HANDRAIL PROJECTION OF 4-1/2" ON EITHER SIDE OF THE STAIRWAY.
2. (R311.7.2) MIN HEAD ROOM = 6'-8" FINISH FROM NOSING LINE AND MINIMUM FINISH WIDTH = 36"
3. (R311.7.3) MAX RISE OF STAIRWAY BETWEEN LEVELS AND LANDINGS IS 151"
4. (R311.7.5) MAX RISE = 7-3/4" AND MINIMUM TREAD DEPTH = 10" (11" TREAD REQUIRED IN ABSENCE OF
NOSING.)
5. EVERY STAIRWAY LANDING SHALL HAVE A DIMENSION MEASURED IN THE DIRECTION OF TRAVEL, AT LEAST
EQUAL TO THE STAIRWAY WIDTH.
6. A DOOR MAY OPEN AT THE TOP OF THE STEP OF AN INTERIOR FLIGHT OF STAIRS PROVIDED THE DOOR DOES
NOT SWING OVER THE TOP STEP, AND PROVIDED THE TOP STEP IS NO MORE THAN 8" LOWER THAN FLOOR
LEVEL.
7. (3) 1-1/4" X 11-7/8" LVL STRINGERS REQUIRED AT ALL STAIRWAYS.
8. (R302.7) MIN OF 1/2" GYPSUM WALL BOARD ON ALL ACCESSIBLE WALLS AND ENCLOSED UNDERSIDE OF
STAIRS
WEATHER PROTECTION / FLASHING:
1. INSTALL (1) LAYER OF GRADE "D" OR BETTER (15LB) FELT UNDER ASPHALT ROOF SHINGLES.
2. ANY ROOF PITCH BETWEEN 2:12 AND 4:12 WILL RECEIVE A DOUBLE LAYER OF GRADE "D" FELT OR BETTER
UNDERLAYMENT.
3. (IRC 2018 R905.1.2 / R905.2.7) INSTALL (1) LAYER OF NO. 40 COATED ROOFING OR COATED GLASS BASE FROM
THE ROOF EAVES TO A LINE 24" INSIDE THE EXTERIOR WALL LINE WITH ALL LAPS CEMENTED TOGETHER.
4. INSTALL (1) LAYER OF NO. 40 COATED ROOFING OR COATED GLASS BASE TO ALL ROOF VALLEY CONDITIONS.
5. INSTALL (1) LAYER OF GRADE "D" (15LB) FELT UNDER ALUMINUM SIDING.
6. INSTALL (1) LAYER OF GRADE "D" (15LB) FELT UNDER BRICK/STONE VENEER.
7. INSTALL (2) LAYERS OF GRADE "D" (15LB) FELT UNDER EXTERIOR INSULATION FINISH SYSTEM (EIFS /
STUCCO). OVERLAP ALL SEAMS.
8. PROVIDE METAL FLASHING OR EQUAL AT ALL FOUNDATION, (OR BRICK AND EIFS TRANSITIONS) WHERE
WATER FROM WEATHER BARRIER COULD ENTERED DWELLING.
9. PROVIDE METAL FLASHING OR 15LB FELT BETWEEN WOOD SHEATHING AND CONCRETE PORCHES,
LANDINGS, STEPS, AND STAIRS.
10. PROVIDE 9" FLASHING, COUNTER FLASHING, AND APPROVED CAULKING AT ALL EXTERIOR WINDOWS AND
DOORS. WINDOWS AND DOORS MUST BE INSTALLED AS PER MANUFACTURER.
RADON MITIGATION:
1. RADON MITIGATION PER IRC AF 101 IN CRAWL SPACE OR UNDER SLAB-ON-GRADE PRESSURIZATION SYSTEM
(PASSIVE) RADON PIPING IN CRAWL SPACE AT BOTTOM OF FOOTING LEVEL PLASTIC WITH 12" OVERLAP ON
PLASTIC JOINTS. VERTICAL TERMINATION OF RADON PIPE THRU THE MECHANICAL ROOM THRU THE ROOF.
VENT/FAN LOCATIONS TO BE FIELD VERIFIED BY CONTRACTOR.
EXCAVATION, BACKFILL, AND GRADING:
1. ALL EXCAVATION FOR FOOTINGS SHALL BE TO NATURAL, UNDISTURBED SOIL, OR ENGINEERED FILL TO
COMPACTION OF 95% IN 8" LIFTS. SHALLOW FOUNDATIONS SHALL COMPLY WITH (IBC 1809).
2. ALL FOOTINGS SHALL BE PLACED ON UNDISTURBED EARTH AND BELOW FROST LINE.
3. (R401.3) FINISH GRADING SHALL BE DONE SO AS TO PROVIDE POSITIVE DRAINAGE AWAY FROM ALL BUILDING
FOUNDATIONS. MIN OF 6" IN FIRST 10'.
4. (2018 IRC R404.1.7) BACKFILL SHALL NOT BE PLACED AGAINST THE WALL UNTIL THE WALL HAS SUFFICIENT
STRENGTH AND HAS BEEN ANCHORED TO THE FLOOR ABOVE, OR HAS BEEN SUFFICIENTLY BRACED TO
PREVENT DAMAGE BY THE BACKFILL.
5. ALL RETAINING WALLS REQUIRE DRAINAGE PER R405.1; CONNECT TO APPROVED DISCHARGE POINT.
APPROVED FILTER MEMBRANE REQUIRED AROUND PERFORATED PIPE OR COVERING SURROUNDING ROCK
(R405.1 FOR OTHER DRAIN TYPES AND MATERIALS)
FIRE PROTECTION AND WARNING:
1. (R302.6) PROVIDE ONE LAYER OF 5/8" TYPE "X" GYP BOARD ON ALL WALLS AND CEILING OF THE GARAGE
COMMON TO LIVING AREAS, WALLS SUPPORTING UPPER FLOOR AND ANY EXPOSED BEAMS AND POSTS.
2. (R302.7) ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE THE WALL UNDER THE STAIR SURFACE
AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2" GYP BOARD.
3. (R302.5.1) DOORS LEADING FROM GARAGE INTO LIVING AREA SHALL BE SOLID WOOD, SOLID OR HONEYCOMB
CORE STEEL DOOR NOT LESS THAN 1-3/8" THICK OR HAVING A FIRE RATING PROTECTION OF NOT LESS THAN
20MIN WHEN TESTED.
4. (R302.5.1) MUST HAVE TWO SELF CLOSING HINGES ON 20 MINUTE RATED DOORS.
5. (R314) SMOKE AND CARBON MONOXIDE DETECTORS ARE REQUIRED TO MEET LOCAL CODES. WIRED IN
SERIES WITH BATTERY BACKUP ON DEDICATED BREAKER.
RAILINGS:
1. HANDRAILS ARE REQUIRED AT ALL STAIRWAYS HAVING FOUR OR MORE RISERS. SEE (SECTION R311.7.8.5)
FOR GRIP SIZE OPTIONS (REFERENCE 2018 IRC R311 & R312)
2. PROVIDE 1-1/4" TO 2-5/8" HANDRAILS 34" TO 38" IN HEIGHT THAT RUN CONTINUOUS AND HAVE RETURNING
ENDS TO WALL, NEWEL POST, OR SAFETY TERMINAL. OR 12" PAST LAST TREAD.
3. HANDRAILS DEEPER THEN 2-5/8" SHALL HAVE A FINGER GROOVE 3/4" X 1/4" DEEP ROUTED THE ENTIRE
LENGTH OF AT LEAST ONE SIDE OF HANDRAIL.
4. GUARDS SHALL BE LOCATED ALONG OPEN-SIDED WALKING SURFACES INCLUDING STAIRS, RAMPS AND
LANDING, THAT ARE LOCATED MORE THAN 30” ABOVE LEVEL BELOW. GUARD HEIGHT SHALL NOT BE LESS
THAN 36”
5. GUARD RAIL SHALL HAVE INTERMEDIATED RAILS OR ORNAMENTAL CLOSURES THAT DO NOT ALLOW PASSAGE
OF A SPHERE 4” IN DIAMETER.
FOUNDATION NOTE:
1. SEE FOUNDATION WALL SCHEDULE FOR FOUNDATION WALL SIZE, REBAR SPACING, & J-BOLT/ ANCHOR
LOCATIONS.
2. PRESSURE TREATED SILL PLATE AT PERIMETER OF FOUNDATION
3. SEE FOOTING SCHEDULE FOR FOOTING SIZE AND REBAR PLACEMENT. ALL FOOTINGS TO BEAR ON APPROVED
STRUCTURAL FILL OR UNDISTURBED SOIL.
4. (IBC 1806.2) FOOTING DESIGN IS BASED ON SOIL LOAD-BEARING CAPACITY OF 1500 PSF BASED ON A CLAY,
SANDY CLAY, SILTY CLAY, CLAYEY SILT, SILT, AND SANDY SILT. IF CONTRACTORS ENCOUNTER EXPANSIVE SOILS
OR OTHER PROBLEMS, THE SITE MUST BE APPROVED BY A SOILS ENGINEER PRIOR TO POURING FOOTINGS IN
THAT AREA. BEAR FOOTING ON SAME TYPE OF UNDISTURBED SOIL OR ROCK THROUGHOUT THE ENTIRE
STRUCTURE.
5. CONCRETE FOR FOOTINGS AND FOUNDATION WALLS TO HAVE A 28 DAY MINIMUM COMPRESSIVE STRENGTH OF
3000 PSI. 2500 PSI USED IN DESIGN, THEREFORE NO SPECIAL INSPECTIONS ARE REQUIRED.
6. LAP REBAR SPLICES IN ACCORDANCE WITH 2018 IRC 403.1.5.4. THE MAXIMUM GAP BETWEEN NONCONTACT
PARALLEL BARS AT A LAP SPLICE SHALL NOT EXCEED THE SMALLER OF 1/5 THE REQUIRED LAP LENGTH AND 6
INCHES.
7. REINFORCING STEEL SHALL BE GRADE 60 FOR ALL REBAR.
8. (2018 IRC SECTION 406) DAMP PROOF FOUNDATION WALLS IN ACCORDANCE TO SECTION 406.
9. CRAWL SPACE VENTILATION @ 1:150 RATIO & PLACE (1) VENT WITHIN 3' OF EACH CORNER.
10. (2018 IRC R408.4) 18" X 24" MINIMUM CRAWLSPACE ACCESS HOLE.
11. THE THICKNESS OF CONCRETE FLOOR SLABS SUPPORTED DIRECTLY ON THE GROUND SHALL NOT BE LESS
THAN 3.5" (98 MM). A6-MIL (0.006 INCH; 0.15 MM) POLYETHYLENE VAPOR RETARDER. CONTROL JOINTS @ 25' O.C.
MAX EA. DIR. OR CENTERED PER OWNER PREFERENCE.
12. COMPLY W/ ACI 306R COLD WEATHER CONCRETE STANDARDS IF THE MEAN DAILY TEMPERATURE IS EXPECTED
TO DROP BELOW 40ºF FOR 3 OR MORE SUCCESSIVE DAYS. DO NOT PLACE CONCRETE AGAINST FROZEN
EARTH.
13. COMPLY WITH ACI 305R HOT WEATHER CONCRETE STANDARDS.
14. CONTROL JOINTS IN LARGE AREAS OF SLAB ON GRADE SHALL BE PLACED IN CHECKERBOARD FASHION IN
LENGTHS NOT TO EXCEED 20 FEET IN ANY DIRECTION.
15. ALL CONSTRUCTION JOINTS SHALL BE LOCATED AS NOT TO IMPAIR THE STRENGTH OF THE STRUCTURE, U.N.O
ON THE DRAWINGS. ALL REINFORCEMENT SHALL BE CONTINUOUS THROUGH THE JOINTS.
16. ANCHOR BOLTS SHALL BE A36/ F1554 GRADE 36 OR BETTER. CONTRACTOR SHALL COMPLY WITH FOUNDATION
ANCHORAGE PER IRC 2018 R403.1.6(.1)
17. (2018 IRC R403.1.3.1) CONTRACTOR SHALL COMPLY WITH CONCRETE STEM WALLS WITH CONCRETE FOOTINGS
FOR REINFORCEMENT U.N.O ON FOUNDATION WALLS
18. (2018 IRC R403.1.3.5.3) ALL REINFORCEMENT SHALL BE SECURED IN THE PROPER LOCATION IN THE FORMS WITH
TIE WIRE OR OTHER BAR SUPPORT SYSTEM TO PREVENT DISPLACEMENT DURING THE CONCRETE PLACEMENT
OPERATION. CAST AGAINST EARTH SHALL HAVE A MIN. COVER OF 3", REMOVABLE FORMS THAT WILL BE
EXPOSED TO EARTH OR WEATHER SHALL BE 1.5" FOR NO. 5 BARS AND SMALLER, AND FOR NO. 6 BARS AND
LARGER, 2". FOR CONCRETE CAST IN REMOVABLE FORMS THAT WILL NOT BE EXPOSED TO THE EARTH OR
WEATHER, AND FOR CONCRETE CAST IN STAY-IN-PLACE FORMS, MIN. COVER SHALL BE 3/4".
GENERAL FRAMING NOTE:
1. EXTERIOR WALL FRAMING SHALL BE CONVENTIONAL 2x6 FRAMING @ 16" O.C. U.N.O.
2. IF LUMBER GRADING IS NOT SPECIFIED, ASSUME SPF#2 OR BETTER.
3. WOOD STRUCTURAL PANELS TO CONFORM TO IBC 2306.3 SHALL BE CONSTRUCTED IN ACCORDANCE WITH
SDPWS 4.3.6 & 4.3.7. (SEE SHEAR OR BRACE WALL PANEL SCHEDULE FOR WALL SHEATHING AND FASTENING.)
4. ENSURE THAT WALLS TALLER THAN 10' HAVE BLOCKING @ PANEL EDGES AND FIRE BLOCKING.
5. ENSURE THAT INTERIOR BEARING WALLS ARE SUPPORTED IN FLOOR BY BLOCKING OR DOUBLE JOISTS.
6. ENSURE THAT COLUMNS INDICATED ON MAIN OR UPPER FLOORS ARE DIRECTLY SUPPORTED BY BEAMS OR
COLUMNS IN LOWER FLOORS OR SOLID BLOCKING. PROVIDE POSITIVE CONNECTIONS BETWEEN UPPER AND
LOWER.
7. INSTALL ALL HANGERS, HOLD DOWNS, TIES, AND ANCHORS & CAPS AS SPECIFIED PER MANUFACTURER
DOCUMENTATION.
8. ENSURE THAT WINDOWS & DOORS ARE FLASHED AND SEALED OVER AN APPROVED WALL/ROOFING
MEMBRANE TO ENSURE MOISTURE PROTECTION
9. INSTALL SIDING PER MANUFACTURER REQ., INCLUDING RAIN SCREEN OR OTHER APPROVED SIDING.
10. ENSURE TIMBER CONNECTIONS ARE ADEQUATELY SUPPORTED AND BRACED WHERE THEY CONNECT TO
THE LIGHT FRAME STRUCTURE.
11. (IBC 2308.4.2.4) DO NOT NOTCH ANY STRUCTURAL WOOD MEMBER UNLESS SHOWN ON THE DRAWINGS
12. INSTALL AND FOLLOW ALL MANUFACTURES GUIDELINES FOR ENGINEERING WOOD I MEMBERS AND LVL
PRODUCTS. DO NOT NOTCH OR CUT FLANGES OF ENGINEERED WOOD I MEMBERS, UNLESS APPROVED PER
MANUFACTURER.
13. PLYWOOD FACE GRAIN MUST BE PERPENDICULAR TO ITS SUPPORTS.
14. WHEREVER POSSIBLE NAILS SHOULD BE DRIVEN PERPENDICULAR TO THE GRAIN INSTEAD OF TOENAIL.
15. GLUE-LAMINATED BEAMS SHALL COMPLY WITH THE FOLLOWING:
A. (IBC REPORT 2519) I.B.C. COMBINATION 24F-V4 FOR SIMPLE SPANS, 24F-V8 FOR MULTIPLE SPANS OR
CANTILEVER BEAMS. LUMBER SHALL BE DOUGLAS FIR 2400 PSI. CAMBER FOR DEAD LOAD AS SHOWN ON
DRAWINGS.
B. FAILURE OF GLUE-LAMINATED BEAM PLACEMENT REQUIRES MANUFACTURER CONSULTING WHETHER
REMOVAL OF BEAM IS NECESSARY.
C. WET USE ADHESIVES SHALL BE USED ON ALL GLULAM MEMBERS SUBJECTED TO POSSIBLE MOISTURE.
ROOF FRAMING NOTE:
1. ROOF TRUSSES TO BE DESIGNED AND ENGINEERED BY SUPPLIER TO MEET THE DESIGN LOADS HEREIN
INDICATED IN ADDITION TO ANY AND ALL DRIFTING LOADS, WIND LOADS, EQUIPMENT LOADS AND OTHER
LOADS AS INDICATED ON FRAMING PLAN.
2. TRUSS MANUFACTURER TO PROVIDE TRUSS TO TRUSS CONNECTION DETAILS
3. SIMPSON H1 TIES OR BETTER @ EA. TRUSS.
4. PROVIDE GANG STUDS UNDER ALL GIRDER TRUSSES, PLY TO MATCH PLY OF GIRDER TRUSS U.N.O.
5. 5/8 OSB DECKING W/ 16 GAUGE STAPLES OR BETTER @ 3/12 SPACING.
6. ICE /WATER BARRIER @ ALL EDGES, EAVES, GABLES, RIDGES & VALLEYS TO 24" OF INTERIOR DIMENSION.
(SEE #6 IN WEATHER PROTECTION AND FLASHING SECTION)
7. ROOFING FELT (SEE WEATHER PROTECTION AND FLASHING SECTION)
8. DRIP EDGE & SHINGLES/METAL PER OWNER/BUILDER.
9. (2) SIMPSON H2.5A CLIPS @ EACH GIRDER TRUSS U.N.O.
10. PROVIDE ATTIC VENTILATION @ 1:150 OR PER LOCAL CODE. ENCLOSED ATTICS AND RAFTERS SPACES SHALL
HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE AND THE OPENINGS SHALL BE PROTECTED AGAINST
THE ENTRANCE OF RAIN OR SNOW.
GENERAL STRUCTURAL NOTE:
1. (IBC SECTION 101.3) THE STRUCTURAL SYSTEMS AND MEMBERS DEPICTED HEREIN HAVE BEEN DESIGNED
PRIMARILY TO SAFEGUARD AGAINST MAJOR STRUCTURAL DAMAGE AND LOSS OF LIFE, NOT TO LIMIT DAMAGE
OR MAINTAIN FUNCTION.
2. THESE DRAWINGS, AND THEIR ASSOCIATED STRUCTURAL CALCULATIONS, HAVE BEEN PERFORMED USING
STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR
CIRCUMSTANCES BY REPUTABLE STRUCTURAL ENGINEER'S IN THIS OR SIMILAR LOCALITIES. THEY
NECESSARILY ASSUME THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR
AND/OR WORKMEN WHO HAVE A WORKING KNOWLEDGE OF THE INTERNATIONAL BUILDING CODE
CONVENTIONAL FRAMING REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. NOT
EVERY CONDITION OR FRAMING ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, IT IS
UNDERSTOOD THAT THE CONTRACTOR WILL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR ALL
MISCELLANEOUS WORK NOT EXPLICITLY SHOWN.
3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF
CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS,
TECHNIQUES, SEQUENCES AND PROCEDURES. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED
ON FRAMED CONSTRUCTION SUCH THAT DESIGN LIVE LOAD PER SQUARE FOOT AS STATED HEREIN IS NOT
EXCEEDED. OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF AN OPTION IS USED, THE CONTRACTOR
SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES, AND SHALL COORDINATE ALL DETAILS.
4. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND
SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. TYPICAL DETAILS AND NOTES ARE NOT
NECESSARILY REFERENCED ON THE PLANS BUT SHALL APPLY NONETHELESS. WHERE NO DETAILS ARE SHOWN,
CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. DETAILS MAY SHOW ONLY ONE SIDE OF
CONNECTION OR MAY OMIT INFORMATION FOR CLARITY.
5. ANY INSPECTIONS, SPECIAL (IBC CHAPTER 17) OR OTHERWISE THAT ARE REQUIRED BY THE BUILDING CODES,
LOCAL BUILDING DEPARTMENTS, OR BY THESE PLANS SHALL BE DONE BY AN INDEPENDENT INSPECTION
COMPANY OR THE BUILDING DEPARTMENT, SITE VISITS BY THE STRUCTURAL ENGINEER DO NOT CONSTITUTE
AN OFFICIAL INSPECTION, UNLESS SPECIFICALLY CONTRACTED FOR.
CODES AND SPECIFICATIONS
1. INTERNATIONAL BUILDING CODE (IBC) - 2018 EDITION
2. INTERNATIONAL RESIDENTIAL CODE (IRC) - 2018 EDITION
3. ACI 318-14 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE
4. NATIONAL DESIGN SPECIFICATION (NDS) & SUPPL. FOR WOOD CONST. - 2018 EDITION
5. SPECIAL DESIGN PROVISION FOR WIND & SEISMIC - 2015 EDITION
6. ASCE 7-16 MIN. DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES.
GENERAL NOTES
1. ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION SHALL BE
PROVIDED BY THE BUILDER.
2. ANY PROPOSED FIELD CHANGES SHALL HAVE PRIOR APPROVAL FROM THE ENGINEER.
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD. ANY VARIATION FROM THE DRAWINGS SHALL BE
BROUGHT TO THE ATTENTION OF THE ENGINEER.
4. INSTALL SIMPSON HARDWARE AS PER MANUFACTURERS REQUIREMENTS.
5. DETAILS ARE REPRESENTATIONS/ DEPICTIONS ONLY. FOLLOW WRITTEN CALLOUTS.
6. NO CHANGES PERMITTED WITHOUT EXPRESS WRITTEN PERMISSION OF ENGINEER OF RECORD.
7. (2018 IRC CHAPTER 14)HEATING & COOLING EQUIPMENT / APPLIANCES SHALL BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURER'S INSTALLATION REQUIREMENTS.
DECKS:
1. (R507) WOOD-FRAMED DECKS SHALL BE IN ACCORDANCE WITH SECTION 507. (SEE FLOOR FRAMING PAGE
FOR DECK SIZING AND MATERIAL TYPE)
2. (R317) WOOD MATERIALS SHALL BE NO. 2 GRADE OR BETTER LUMBER, WOOD FRAMING LESS THAN 18"
ABOVE GRADE SHALL BE IN COMPLIANCE WITH R317.1 (IRC 2018). CONTRACTOR TO VERIFY FINAL HEIGHT
FROM FINISHED GRADE.
REMODEL/ADDITION/EXISTING NOTE:
1. THIS ARCHITECTURAL DESIGN INCORPORATES MODIFICATIONS TO EXISTING STRUCTURES. WHILE EFFORTS
HAVE BEEN MADE TO INCLUDE ACCURATE INFORMATION, THE BUILDER/OWNER IS RESPONSIBLE FOR
VERIFYING ALL MEASUREMENTS, COMPLIANCE WITH BUILDING CODES, AND ON-SITE CONDITIONS. THE
BUILDER/OWNER ASSUMES RESPONSIBILITY FOR VERIFYING ALL ASPECTS OF THE DESIGN IN CONJUNCTION
WITH EXISTING STRUCTURES PRIOR TO CONSTRUCTION OR PURCHASING OF MATERIALS. AS DEMOLITION
AND CONSTRUCTION PROGRESS, PROMPTLY INFORM OUR TEAM OF ANY DISCREPANCIES THAT MAY ARISE.
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
GE
N
E
R
A
L
NO
T
E
S
SH
E
E
T
TI
T
L
E
:
G-102
PLN# 247-01-011
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.
OWNER: REXBURG
RENTALS LLC
LEGAL DESCRIPTION:
PARKER ADDITION TO
REXBURG TAX 3491
LOT 1 BLK 4
Parcel Number:
RPR000P0040080
ACRES: 0.123
41.1'
130.5'
41.1'
129.5'
SECTION TO BE DEMOLISHED
2ND S
CORNELL AVE.
EXISTING
BUILDING
EXISTING
BUILDING
EXISTING
BUILDING
EXISTING
DRIVEWAY
1 SITE PLAN
SCALE: 3/32" = 1'-0"
SITE PLAN NOTE:
1. SOUTH FORK DESIGN GROUP DOES NOT PROVIDE SURVEYING, CIVIL
ENGINEERING OR GEO TECHNICAL ENGINEERING. IT IS THE RESPONSIBILITY OF
THE OWNER/CONTRACTOR TO ACQUIRE THESE SERVICES IF APPLICABLE. FINAL
PLACEMENT OF STRUCTURE IS THE RESPONSIBILITY OF THE OWNER/CONTRACTOR.
2. U.N.O. THE SITE PLAN IS BASED ON MEASUREMENTS OBTAINED FROM PUBLIC
RECORD DOCUMENTS OR GIS SYSTEM INFORMATION AND MAY NOT BE EXACT.
3. IT IS THE OWNERS/CONTRACTORS RESPONSIBILITY TO OBTAIN NECESSARY
SURVEY DATA, INCLUDING TOPOGRAPHICAL INFORMATION
4. LOCATION OF UTILITIES SHOULD BE CONFIRMED BY THE CONTRACTOR PRIOR TO
EXCAVATION
5. WHERE SEPTIC AND/OR FRESH WATER WELLS ARE NECESSARY, PERMITS AND
LOCATION SHOULD BE OBTAINED FROM THE AUTHORITY HAVING JURISDICTION
(TYPICALLY HEALTH DEPT)
6. INDICATED LOCATIONS OF SEPTIC, WELL, AND/OR UTILITIES ARE ASSUMED OR
SUGGESTED AND SHOULD BE VERIFIED AND APPROVED BY THE
OWNER/CONTRACTOR AND THE AUTHORITY HAVING JURISDICTION
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
SI
T
E
SH
E
E
T
TI
T
L
E
:
C-101
PLN# 247-01-011
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.
2
2
UP
UP
W
DR
5
2
2 2
6
6
1
2
2
DW
3
F
1
A-
3
0
1
1
A-
3
0
1
2
A-301
2
A-301
3'-2"3'-71/4"
4'
12'-81/4"8'-5"
25
'
-
1
1
"
10'-7"
20'-8"
11
'
11'-81/64"
11
'
-
1
"
10
'
-
1
1
33
/
6
4
"
4'
-
5
"
10
'
-
6
31
/
6
4
"
EGRESS
EGRESS
EGRESS
DOOR UNDER EXISTING LINTEL - MAY NEED
REINFORCEMENT AFTER CUTTING OUT DOOR
- VERIFY WITH ENGINEER
KITCHEN
LIVING
ROOM
BEDROOM 2 BEDROOM 3
STORAGE
LAUNDRY
PANTRY
MASTER
BEDROOM
MASTER
BATHROOM BATHROOM
W.I.C.
WINDOW SCHEDULE
ID
A
TYPE
CASEMENT
QTY
1
SIZE
W
3'
HT
4'
HEAD
HEIGHT
6'-83/4"
TEMPERED
---
NOTES
DOOR SCHEDULE
ID
1
2
3
4
5
6
7
QTY
1
13
1
1
1
2
2
LOCATION
Interior
Interior
Interior
Interior
Exterior
Interior
Interior
FIRE RATING
---
---
---
---
---
---
---
DOOR
W
2'
2'-6"
2'-8"
2'-10"
3'
5'
6'
HT
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
NOTES
SLIDING DOOR
1 MAIN LEVEL PLAN
SCALE: 1/4" = 1'-0"
DASHED LINES REPRESENTS EXISTING CONSTRUCTION
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
MA
I
N
LE
V
E
L
SH
E
E
T
TI
T
L
E
:
A-101
PLN# 247-01-011
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.
2 2
UP
2
7
2
7
2
2
A
4
DW
W
DR
47'-1"
1'-1"
2'5'-11"3'-81/2"2'
1'
-
6
"
1'
-
1
1
"
4'
-
8
"
2'
-
1
"
9'-6"
10
'
-
1
1/
2
"
3'
-
7
"
10
'
-
6
1/
2
"
2'10'-10"5'
8'
-
9
"
11'-923/64"
5'
EGRESS
EGRESS
EGRESS
MASTER
W.I.C.
LAUNDRY
MASTER
BATH
BATHBEDROOM 3
BEDROOM 2KITCHEN
LIVING ROOM
EXISTING CEILING
HEIGHT APPROX
7'-5" (TYP)
1
A-
3
0
1
1
A-
3
0
1
2
A-301
2
A-301
F
2'-123/64"
7'-41/2"
1'-2"
2'-1"
WINDOW SCHEDULE
ID
A
TYPE
CASEMENT
QTY
1
SIZE
W
3'
HT
4'
HEAD
HEIGHT
6'-83/4"
TEMPERED
---
NOTES
DOOR SCHEDULE
ID
1
2
3
4
5
6
7
QTY
1
13
1
1
1
2
2
LOCATION
Interior
Interior
Interior
Interior
Exterior
Interior
Interior
FIRE RATING
---
---
---
---
---
---
---
DOOR
W
2'
2'-6"
2'-8"
2'-10"
3'
5'
6'
HT
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
NOTES
SLIDING DOOR
1 BASEMENT LEVEL PLAN
SCALE: 1/4" = 1'-0"
DASHED LINES REPRESENTS EXISTING CONSTRUCTION
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
LO
W
E
R
LE
V
E
L
SH
E
E
T
TI
T
L
E
:
A-102
PLN# 247-01-011
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.
UP
UP
UP
UP
UP
1 MAIN STORY DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
2 LOWER STORY DEMOLITION
SCALE: 1/4" = 1'-0"
DASHED LINES REPRESENTS PORTION TO BE MODIFIED OR
REMOVED
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
DE
M
O
L
I
T
I
O
N
PL
A
N
SH
E
E
T
TI
T
L
E
:
A-103
PLN# 247-01-011
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.
AP
P
R
O
X
.
23
'
-
1
1
47
/
6
4
"
TO
EX
I
S
T
I
N
G
RI
D
G
E
5
A
2
WINDOW SCHEDULE
ID
A
TYPE
CASEMENT
QTY
1
SIZE
W
3'
HT
4'
HEAD
HEIGHT
6'-83/4"
TEMPERED
---
NOTES
DOOR SCHEDULE
ID
1
2
3
4
5
6
7
QTY
1
13
1
1
1
2
2
LOCATION
Interior
Interior
Interior
Interior
Exterior
Interior
Interior
FIRE RATING
---
---
---
---
---
---
---
DOOR
W
2'
2'-6"
2'-8"
2'-10"
3'
5'
6'
HT
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
NOTES
SLIDING DOOR
1 RIGHT ELEVATION
SCALE: 1/4" = 1'-0"
2 REAR ELEVATION
SCALE: 1/4" = 1'-0"
3 LEFT ELEVATION
SCALE: 1/4" = 1'-0"
4 FRONT ELEVATION
SCALE: 1/4" = 1'-0"
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
EL
E
V
A
T
I
O
N
S
SH
E
E
T
TI
T
L
E
:
A-201
PLN# 247-01-011
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.
7'
-
8
"
KITCHEN LIVING ROOM
KITCHEN LIVING ROOM
7'
-
8
"
EXISTING ROOF
TO BE
REINFORCED
KITCHEN W.I.C.
KITCHEN
KITCHEN MASTER
BEDROOM
BEDROOM BEDROOM
W.I.C.
STORAGE
1 SECTION A
SCALE: 1/4" = 1'-0"
2 SECTION B
SCALE: 1/4" = 1'-0"
DASHED LINES DENOTES EXISTING
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
SE
C
T
I
O
N
S
SH
E
E
T
TI
T
L
E
:
A-301
PLN# 247-01-011
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.
1
1
21'-7"2'
1'-7"2'
-
7
1/
2
"
1'
-
4
"
10
'
-
4
3/
4
"
1'
-
4
"
9'
-
1
1
3/
4
"
25
'
-
8
"
8'
-
7
1/
2
"
1'
-
4
"
15
'
-
2
1/
2
"
5'-9"
1'
-
3
"
11
'
40'-10"6'-3"
10'-3"2'
10
'
-
49
/
6
4
"
2'
1'
-
1
1
1/
2
"
2'
9'
-
7
47
/
6
4
"
10
'
-
3/
4
"
9'
-
7
3/
4
"
2'
1'
-
1
1
1/
2
"
2'
10
'
-
4
3/
4
"
3'
-
7
1/
2
"
2'
9'
-
7
3/
4
"
16'-71/2"2'-111/2"2'
F9 F1
F1
F14
F14
L?
F9 F1
F9
F9 F9
1
A-
3
0
1
1
A-
3
0
1
2
A-301
2
A-301
FOOTING SCHEDULE
ID
F1
F9
F14
WIDTH
16"
24"
---
DEPTH
8"
10"
---
FOOTING TYPE
CONTINUOUS FOOTING
24” X 24” X 10” SPREAD FOOTER
BIGFOOT 24
FOOTING REBAR
(2) #4 BAR CONT.
(3) #4 BOTH WAYS
SEE PIER REBAR FOR SIZING
PIER (IF REQUIRED)
---
---
10" SONOTUBE (4) #4 BAR #3 TIES 8" O.C.
SIMPSON TIES
SYM
1
7
ID
1
7
QTY
2
3
TYPE
ABU66Z
DTT1Z
SPACING
5 FOUNDATION PLAN
SCALE: 1/4" = 1'-0"
DASHED LINES REPRESENTS EXISTING CONSTRUCTION
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
FO
U
N
D
A
T
I
O
N
SH
E
E
T
TI
T
L
E
:
S-101
PLN# 247-01-011
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.
7
7
7
2X
6
@
16
"
O.
C
.
(3) 1 3/4" X 7 1/4" LVL
(2) 2X12 SPF
2X8 LEDGER ATTACH USING 3-5/8" LEDGERLOK @ 16" O.C.
PREVIOUS BEARING TO BE REMOVED ONCE BEAM IS INSTALLED
(3) 1 3/4" X 7 1/4" LVL
(2) 1-3/4"X7-1/4" LVL
NOTCH COLUMN FOR 2X12
ATTACH USING (2) THRULOK 7 OR EQ.
(TYP.)
LUC26Z HANGER (TYP.)
6X6 COL. TYP.
DTT1Z @ 4' O.C.
1
A-
3
0
1
1
A-
3
0
1
2
A-301
2
A-301
SIMPSON TIES
SYM
1
7
ID
1
7
QTY
2
3
TYPE
ABU66Z
DTT1Z
SPACING
2 MAIN LEVEL FLOOR FRAMING
SCALE: 1/4" = 1'-0"
DASHED LINES REPRESENTS EXISTING CONSTRUCTION
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
FL
O
O
R
FR
A
M
I
N
G
SH
E
E
T
TI
T
L
E
:
S-201
PLN# 247-01-011
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.
2 2
UP
2
7
2
7
2
2
A
4
DW
W
DR
6'-11/2"3'-11/2"9'-1"6'
3'
-
1
1
1/
2
"
2'
-
5
1/
2
"
7'
-
9
"
8'
-
7
"
2'
-
4
"
2'-41/2"
3'-11/2"10'-51/2"5'-31/2"5'-51/2"
6'-3"
EGRESS
H7
EGRESS
EGRESS
H7 H7
C2
C1
C1
H7
C2
C1
C1 C1
C7
H7
C8
C8
MASTER
W.I.C.
LAUNDRY
MASTER
BATH
BATHBEDROOM 3
BEDROOM 2KITCHEN
LIVING ROOM
EXISTING CEILING
HEIGHT APPROX
7'-5" (TYP)
1
A-
3
0
1
1
A-
3
0
1
2
A-301
2
A-301
F
HEADERS
ID
H7
PLY
2
SIZE
2X6 SPF
NOTE
COLUMN SCHEDULE
ID
C1
C2
C7
C8
MATERIAL
(3) 2X4 SPF #2 OR BETTER
(4) 2X4 SPF #2 OR BETTER
4X4 SPF #1 OR BETTER
6X6 SPF #1 OR BETTER
WINDOW SCHEDULE
ID
A
TYPE
CASEMENT
QTY
1
SIZE
W
3'
HT
4'
HEAD
HEIGHT
6'-83/4"
TEMPERED
---
NOTES
DOOR SCHEDULE
ID
1
2
3
4
5
6
7
QTY
1
13
1
1
1
2
2
LOCATION
Interior
Interior
Interior
Interior
Exterior
Interior
Interior
FIRE RATING
---
---
---
---
---
---
---
DOOR
W
2'
2'-6"
2'-8"
2'-10"
3'
5'
6'
HT
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
NOTES
SLIDING DOOR
4 BASEMENT LEVEL WALL FRAMING
SCALE: 1/4" = 1'-0"
DASHED LINES REPRESENTS EXISTING CONSTRUCTION
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
WA
L
L
FR
A
M
I
N
G
SH
E
E
T
TI
T
L
E
:
S-301
PLN# 247-01-011
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.
2
2
UP
UP
W
DR
5
2
2 2
6
6
1
2
2
DW
3
F
1
A-
3
0
1
1
A-
3
0
1
2
A-301
2
A-301
76'-4"
17'-6"4'-41/2"24'-61/2"8'-11"21'
76'-4"
29
'
-
2
"
1'
-
2
"
8"
1'
-
1/
2
"
10
'
-
3
1/
2
"
4'
-
1
0
"
11
'
-
2
"
12'5'-91/2"5'-833/64"9'-2"
1'-10"
12'-7"7'-5 1/2"21'
29
'
-
2
"
7'
-
1
0
27
/
6
4
"
3'
-
5
37
/
6
4
"
1'
-
1
0
"
21/
2
"
11
'
-
4
"
2'
11
'
-
4
"
2'
-
5
"
1"
5'-9"3'-8"13'-2"20'-363/64"11'-31/2"
14
'
-
5
1/
2
"
10
1/
2
"
10
'
-
4
"
5'
-
8
"
5'
5'
2'
-
9
1/
2
"
8'
-
2
"
6'
12
'
EGRESS
EGRESS
H7
H10
C2
EGRESS
H7 H7
H7
DOOR UNDER EXISTING LINTEL - MAY NEED
REINFORCEMENT AFTER CUTTING OUT DOOR
- VERIFY WITH ENGINEERC8C8C2 C2C2
KITCHEN
LIVING
ROOM
BEDROOM 2 BEDROOM 3
STORAGE
LAUNDRY
PANTRY
MASTER
BEDROOM
MASTER
BATHROOM BATHROOM
W.I.C.
4'-4"12'-7"11'-111/2"16'-101/2"
2'-6"5'-331/64"
HEADERS
ID
H7
PLY
2
SIZE
2X6 SPF
NOTE
COLUMN SCHEDULE
ID
C1
C2
C7
C8
MATERIAL
(3) 2X4 SPF #2 OR BETTER
(4) 2X4 SPF #2 OR BETTER
4X4 SPF #1 OR BETTER
6X6 SPF #1 OR BETTER
WINDOW SCHEDULE
ID
A
TYPE
CASEMENT
QTY
1
SIZE
W
3'
HT
4'
HEAD
HEIGHT
6'-83/4"
TEMPERED
---
NOTES
DOOR SCHEDULE
ID
1
2
3
4
5
6
7
QTY
1
13
1
1
1
2
2
LOCATION
Interior
Interior
Interior
Interior
Exterior
Interior
Interior
FIRE RATING
---
---
---
---
---
---
---
DOOR
W
2'
2'-6"
2'-8"
2'-10"
3'
5'
6'
HT
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
NOTES
SLIDING DOOR
4 MAIN LEVEL WALL FRAMING
SCALE: 1/4" = 1'-0"
DASHED LINES REPRESENTS EXISTING CONSTRUCTION
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
WA
L
L
FR
A
M
I
N
G
SH
E
E
T
TI
T
L
E
:
S-302
PLN# 247-01-011
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.
1
A-
3
0
1
1
A-
3
0
1
2
A-301
2
A-301
NOTE: EXISTING FRAMING SHOWN HERE IS
INSUFFICIENT - ENSURE MIN. (1) 2X8 OR (2) 2X6 SPF
@ 16" O.C. - OKAY TO SISTER SECOND JOIST
ALLONGSIDE UNDAMAGED EXISTING FRAMING
1 FLOOR/ CEILING FRAMING PLAN
SCALE: 1/4" = 1'-0"
DASHED LINES REPRESENTS EXISTING CONSTRUCTION
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
CE
I
L
I
N
G
FR
A
M
I
N
G
SH
E
E
T
TI
T
L
E
:
S-401
PLN# 247-01-011
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.
1
A-
3
0
1
1
A-
3
0
1
2
A-301
2
A-301
EXISTING ROOF
EXISTING ROOF
NOTE: ALL RAFTERS TYP. UNLESS NOTED OTHERWISE
RAFTERS GREATER THAN 8' REQUIRE MIN. (1) 2X8 SPF, OR (2) 2X6 SPF @ 16" O.C.
RAFTERS LESS THAN 8' REQUIRE MIN (1) 2X6 @ 16" O.C.
4x4 COLUMN WITH SIMPSON BC4 POST BASE
(1) 1-3/4"X5-1/2" LVL RAFTERS
SISTER ALONGSIDE EXISTING RAFTERS
- SPAN CONTINUOUS FROM EXTERIOR TO
INTERIOR BEARING WALL4x4 COLUMN WITH SIMPSON BC4 POST BASE
4x4 COLUMN
4x4 COLUMN
4x4 COLUMN
4x4 COLUMN
4x4 COLUMN
4x4 COLUMN
(2) 1-3/4"X5-1/2" LVL BEAM BENEATH
EXISTING HIP BEAM (ALL TYP.)
1 ROOF FRAMING RAFTER PLAN
SCALE: 1/4" = 1'-0"
DASHED LINES REPRESENTS EXISTING CONSTRUCTION
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
RO
O
F
FR
A
M
I
N
G
RA
F
T
E
R
S
SH
E
E
T
TI
T
L
E
:
S-402
PLN# 247-01-011
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.
1
A-
3
0
1
1
A-
3
0
1
2
A-301
2
A-301
EXISTING ROOF
EXISTING ROOF
(2) 1-3/4"X11-7/8" LVL(2) 1-3/4"X11-7/8" LVL
5-1/8"X9" 24F-V4 GLB
5-1/8"X9" 24F-V4 GLB
(2) 1-3/4"X9-1/2" LVL
(2) 1-3/4"X9-1/2" LVL
HUCQ410-SDS
HUCQ410-SDS
FRAME 2X4 WALL UP TO
UNDERSIDE OF RAFTERS
FRAME 2X4 WALL UP TO
UNDERSIDE OF RAFTERS
FRAME 2X4 WALL UP TO
UNDERSIDE OF RAFTERS
FRAME 2X4 WALL UP TO
UNDERSIDE OF RAFTERS
FRAME 2X4 WALL UP TO
UNDERSIDE OF RAFTERS
FRAME 2X4 WALL UP TO
UNDERSIDE OF RAFTERS
FRAME 2X4 WALL UP TO
UNDERSIDE OF RAFTERS
OKAY TO BREAK BEAM HERE - CANTILEVER
BEAM OVER COLUMN TO BREAK
4x4 COLUMN WITH SIMPSON BC4 POST BASE
4x4 COLUMN WITH SIMPSON BC4 POST BASE
4x4 COLUMN
4x4 COLUMN
4x4 COLUMN
4x4 COLUMN
4x4 COLUMN
4x4 COLUMN
HUCQ412-SDSHUCQ412-SDS
1 ROOF FRAMING NO RAFTERS
SCALE: 1/4" = 1'-0"
DASHED LINES REPRESENTS EXISTING CONSTRUCTION
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
RO
O
F
FR
A
M
I
N
G
ST
R
U
C
T
U
R
E
SH
E
E
T
TI
T
L
E
:
S-403
PLN# 247-01-011
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.
GA FILE NO. FC 5529 GENERIC 1 HOUR
FIRE
WOOD JOISTS, GYPSUM WALLBOARD
Fire Design:
Base layer 5/8” type X gypsum wallboard applied at right angles to 2 x 10 wood joists 24”
o.c. with 1-1/4” Type W or S screws 24” o.c. Face layer 5/8” type X gypsum wallboard or
gypsum veneer base applied at right angles to joists with 1-7/8” Type W or S screws 12”
o.c. at joints and intermediate joists and 1-1/2” Type G screws 12” o.c. placed 2” back
on either side of end joints. Wood joists supporting 1/2” plywood with exterior glue
applied at right angles to joists with 8d nails.
Joints offset 24” from base layer joints.
Approx. Ceiling Weight: 5 psf (Fire)
Fire Test: FM FC 172, 2-25-72;
ITS, 8-6-98
EXCERPT TAKEN FROM "GA-600-2018 Fire Resistance and Sound Control Design Manual"
1 HR CEILING/ FLOOR FIRE SEPARATION
FLOOR FIRE ASSEMBLY
NOT TO SCALE
36
SECTION B FIRE KEY
NOT TO SCALE
46
IDAHO RESIDENTIAL CODE FIRE SEPARATION REQUIREMENTS:
R302.3 TWO-FAMILY DWELLINGS
-DWELLING UNITS IN TWO-FAMILY DWELLINGS SHALL BE SEPARATED FROM EACH OTHER BY WALL AND FLOOR
ASSEMBLIES HAVING NOT LESS THAN A 1-HOUR FIRE-RESISTANCE RATING WHERE TESTED IN ACCORDANCE
WITH ASTM E119, UL 263, OR SECTION 703.3 OF THE INTERNATIONAL BUILDING CODE.
-FIRE-RESISTANCE-RATED FLOOR/CEILING AND WALL ASSEMBLIES SHALL EXTEND TO AND BE TIGHT AGAINST
THE EXTERIOR WALL.
R302.3.1 SUPPORTING CONSTRUCTION
WHERE FLOOR ASSEMBLIES ARE REQUIRED TO BE FIRE-RESISTANCE RATED BY SECTION R302.3, THE
SUPPORTING CONSTRUCTION OF SUCH ASSEMBLIES SHALL HAVE AN EQUAL OR GREATER FIRE-RESISTANCE
RATING.
AS SUCH, ALL EXTERIOR WALLS IN BASEMENT TO BE FINISHED USING MIN. (1) 5/8" TYPE X DRYWALL. ALL
INTERIOR BEARING WALLS IN BASEMENT TO HAVE MIN. (1) LAYER 5/8 TYPE X EACH SIDE.
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
DE
T
A
I
L
S
SH
E
E
T
TI
T
L
E
:
R-101
PLN# 247-01-011
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.
UP
DW
W
DR
MASTER
W.I.C.
LAUNDRY
MASTER
BATH
BATHBEDROOM 3
BEDROOM 2KITCHEN
LIVING ROOM
EXISTING CEILING
HEIGHT APPROX
7'-5" (TYP)
S/C
S
SMOKE/CARBON MONOXIDE DETECTOR
SMOKE DETECTOR
S/C
S
S
S
F
1 BASEMENT LEVEL MEP
SCALE: 1/4" = 1'-0"
MEP DRAWING NOTE:
1. THESE DRAWINGS ARE PROVIDED FOR THE MECHANICAL, ELECTRICAL, AND
PLUMBING CONTRACTORS TO MAKE NOTATIONS AND CHANGES ACCORDING TO THE
DIRECTION OF THE HOMEOWNER AND GENERAL CONTRACTOR.
2. IT IS THE RESPONSIBILITY OF THE INDIVIDUAL CONTACTORS TO ENSURE THAT ALL
TRADE-SPECIFIC DESIGN IS DONE ACCORDING TO THE LATEST CODE STANDARDS
AND THE HOME OWNERS PREFERENCE.
3. THE TRADE CONTRACTORS SHALL PRESENT ALL MATERIAL AND FIXTURE
SELECTIONS FOR HOME OWNER APPROVAL PRIOR TO PURCHASE AND
INSTALLATION.
4. IF THE INSTALLATION OF ANY PIPES, DUCTWORK, WIRES OR OTHER MATERIAL
REQUIRE MODIFICATION OF THE SPECIFIED STRUCTURE, THE GENERAL
CONTRACTOR SHALL CONTACT THE STRUCTURAL ENGINEER OR DESIGNER TO
VERIFY THAT SUCH MODIFICATION WILL NOT NEGATIVELY EFFECT THE STRENGTH OF
THE EFFECTED STRUCTURAL ELEMENT.
ATTIC/CRAWLSPACE GENERAL NOTE:
OPENINGS TO ATTIC AND CRAWLSPACE SHALL COMPLY WITH CODE M1305.1.3 &
M1305.1.2 IN THAT ALL APPLIANCES SHALL BE ACCESSIBLE WITHIN 20 FEET OF THE
ACCESS OPENINGS.
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
ME
P
MA
R
K
U
P
PL
A
N
SH
E
E
T
TI
T
L
E
:
E-101
PLN# 247-01-011
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.
UP
UP
W
DR
DW
F
S/C
S
SMOKE/CARBON MONOXIDE DETECTOR
SMOKE DETECTOR
KITCHEN
LIVING
ROOM
BEDROOM 2 BEDROOM 3
STORAGE
LAUNDRY
PANTRY
S/C
S
S S
MASTER
BEDROOM
MASTER
BATHROOM BATHROOM
W.I.C.
1 MAIN LEVEL MEP
SCALE: 1/4" = 1'-0"
MEP DRAWING NOTE:
1. THESE DRAWINGS ARE PROVIDED FOR THE MECHANICAL, ELECTRICAL, AND
PLUMBING CONTRACTORS TO MAKE NOTATIONS AND CHANGES ACCORDING TO THE
DIRECTION OF THE HOMEOWNER AND GENERAL CONTRACTOR.
2. IT IS THE RESPONSIBILITY OF THE INDIVIDUAL CONTACTORS TO ENSURE THAT ALL
TRADE-SPECIFIC DESIGN IS DONE ACCORDING TO THE LATEST CODE STANDARDS
AND THE HOME OWNERS PREFERENCE.
3. THE TRADE CONTRACTORS SHALL PRESENT ALL MATERIAL AND FIXTURE
SELECTIONS FOR HOME OWNER APPROVAL PRIOR TO PURCHASE AND
INSTALLATION.
4. IF THE INSTALLATION OF ANY PIPES, DUCTWORK, WIRES OR OTHER MATERIAL
REQUIRE MODIFICATION OF THE SPECIFIED STRUCTURE, THE GENERAL
CONTRACTOR SHALL CONTACT THE STRUCTURAL ENGINEER OR DESIGNER TO
VERIFY THAT SUCH MODIFICATION WILL NOT NEGATIVELY EFFECT THE STRENGTH OF
THE EFFECTED STRUCTURAL ELEMENT.
ATTIC/CRAWLSPACE GENERAL NOTE:
OPENINGS TO ATTIC AND CRAWLSPACE SHALL COMPLY WITH CODE M1305.1.3 &
M1305.1.2 IN THAT ALL APPLIANCES SHALL BE ACCESSIBLE WITHIN 20 FEET OF THE
ACCESS OPENINGS.
DR
A
W
N
BY
:
CH
K
'
D
BY
:
BW
/
S
W
#1
-
5
Ch
e
c
k
e
d
By
PL
O
T
DA
T
E
:
12
/
3
/
2
0
2
4
EN
G
I
N
E
E
R
:
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
DA
T
E
ME
P
MA
R
K
U
P
PL
A
N
SH
E
E
T
TI
T
L
E
:
E-102
PLN# 247-01-011
EI
T
:
#1
-
4
EN
G
I
N
E
E
R
IN
T
E
R
N
12
7
E.
Ma
i
n
St
.
Su
i
t
e
11
1
Re
x
b
u
r
g
,
ID
83
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
Fo
r
k
De
s
i
g
n
Gr
o
u
p
,
LL
C
PR
E
L
I
M
I
N
A
R
Y
NO
T
FO
R
CO
N
S
T
R
U
C
T
I
O
N
Co
p
y
r
i
g
h
t
20
2
4
|
So
u
t
h
Fo
r
k
De
s
i
g
n
|
Al
l
Ri
g
h
t
s
Re
s
e
r
v
e
d
.
TE
R
E
S
A
CR
A
P
O
15
6
E
2N
D
S
RE
X
B
U
R
G
,
ID
.
ADDITION & REMODEL NOTE:
IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER
TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR
ELEVATIONS, AND INTEGRATION OF THE OVERALL
DESIGN WITH THE EXISTING STRUCTURE.