HomeMy WebLinkAboutREDLINED PLANS 6.7.23 - 23-00358 - Corcoran 6 Unit - ApartmentsAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Don Allen Don.Allen@rexburg.org 208-372-2174 Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : Corcoran 6 Unit - Apartments Address : 358 S 3rd W Application Type : Document Filename : submital plans 6_7_23.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A-1 Free Text Cody Jones : Building Open 1 Commercial plans to be designed by Building Design Professional and stamped. Need Envelope COMM check. Fire partitions to meet requirements of Section 708. Penetrations in rated assemblies to meet comply with Section 714. Concealed spaces to be fire blocked and Draft stopped. (attic to be separated into areas no bigger than 3000 square feet or above every two units whichever is less.) Automatic sprinklers required. Landings at doors and cross slope of sidewalk not to exceed 2%. Doors to meet requirements of Section 1010. Stairways to meet requirements of Section 1011 and 1019. Handrails and guards to be in compliance with 1014 and 1015. # 23-00358 New Multi-Family Residence Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 06.13.2023 Approval of plans does not constitute approval of variance from code Page 1 of 2 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Corridors to be rated and comply with section 1020. (egress balconies section 1021.) Every residence to be Type B units. Ventilation to comply with Section 1203. Dwelling sound transmission to be not less than 50, unless tested. Emergency Escape openings as per section 1030. A-1 Free Text Cody Jones : Building Open 1 Apartments R2 S-001 Free Text Cody Jones : Building Open 5 D S-001 Free Text Cody Jones : Building Open 5 Roof snow load 35. S-001 Free Text Cody Jones : Building Open 5 Frost depth 36". S-101 Note Cody Jones : Building Open 6 Dampproofing/Waterproofing comply with IBC Section 1805 S-101 Note Cody Jones : Building Open 6 Site Grading meets the requirements of IBC Section 1804.4 E-1 Callout Alex Owens : Electrical Open 14 Receptacles required in these locations where they are 24" or wider as per 210.52 E-1 Callout Alex Owens : Electrical Open 14 Receptacles required in these locations where they are 24" or wider as per 210.52 E-1 Callout Alex Owens : Electrical Open 14 Idaho has adopted 2017 NEC, not CEC E-1 Callout Alex Owens : Electrical Open 14 Electrical work inside cloud is above and beyond 2017 NEC requirements. Please verify this is desired. E-1 Free Text Alex Owens : Electrical Open 14 A wall switch-controlled lighting outlet shall be installed in every habitable room (including living rooms) as per 210.70A1 E-1 Callout Alex Owens : Electrical Open 14 Available fault current calculation needed to verify AIC rating for main breaker. A-1 Callout Kyle Baldwin : P&Z Open 1 Sidewalk in Right-of-way must extend to property line A-1 Free Text Kyle Baldwin : P&Z Open 1 Please show snow storage area calculations on Site Plan. Must be 10% of parking lot area A-1 Callout Kyle Baldwin : P&Z Open 1 Sidewalk here must be 6' wide A-1 Callout Kyle Baldwin : P&Z Open 1 Sidewalk connectivity required from internal sidewalk to sidewalk in right-of-way Report Date: 06.13.2023 Approval of plans does not constitute approval of variance from code Page 2 of 2 Powered by TCPDF (www.tcpdf.org) VICINITY MAP SCALE: N.T.S. SUBJECT PROPERTY N WA T E R C / W C / W C / W 20' 25' 10' 10' 20' 20' 9' 37'-10" 20' 20'20'-3" 9'8' S S S S S S (N) 6 UNIT MULTIFAMILY 4/1 5/2 6/3 11 33 2 6 5 44 5 6 S. 3 R D W E S T 115.50' 115.50' 82 . 5 0 ' 82 . 5 0 ' NO PARKING STORM WATER SERVICE 4" SANITARY SEWER HEATED FIRE RISER & ALARM PANEL ROOM TRASH ENCLOSURE (PERVIOUS PAVERS) SNOW STORAGE SNOW STORAGE (N) SOLID FENCE CONNECT ROOF DRAINS TO D.I. REVISIONS SHEET: SCALE: DATE: 11 6/7/2023 PROJECT DATA: A.P.N.RPR000P0103610 LOT SIZE .214 ACRES OCCUPANCY R3/U CONSTRUCTION TYPE VB EXISTING RESIDENCE AREA 969 SF EXISTING GARAGE AREA 200 SF (N) 6 UNITS 3,480 SF UNIT 1 575 UNIT 2 501 UNIT 3 661 UNIT 4 575 UNIT 5 501 UNIT 6 661 SCOPE OF WORK: REMOVE (E) SINGLE DWELLING, CONSTRUCT NEW 6 UNIT APARTMENT BLDG. SHEET INDEX: A-1 SITE PLAN A-2 FLOOR PLANS A-3 EXTERIOR ELEVATIONS A-4 BUILDING SECTIONS S-001 GEN. STRUCTURAL NOTES S-101 FND PLAN S-102 2ND FLR FRAMING PLAN S-103 ROOF FRAMING PLAN S-501 FND DETAILS S-510 FLOOR FRAMING DETAILS S-520 ROOF FRAMING DETAILS S-601 SCHEDULES S-602 SCHEDULES E-1 ELECTRICAL PLANS SITE PLAN SCALE: 1" = 10' JOB NUMBER CO R C O R A N 6 U N I T 35 8 S . 3 R D W E S T RE X B U R G I D A-1 REFERENCED CODES: 2018 INTERNATIONAL BUILDING CODE 2017 NATIONAL ELECTRICAL CODE 2018 MECHANICAL CODE OF IDAHO 2018 IDAHO COMMERCIAL ENERGY CODE 2018 IECC 2015 IDAHO PLUMBING CODE 2018 FIRE CODE OF IDAHO 2009 IDAHO ACCESSIBILITY CODE DR A W N B Y : DA R E N W A R D E L L 19 8 0 2 V I A R E D O N D A R D . SO N O R A C A 9 5 3 7 0 Please show snow storage area calculations on Site Plan. Must be 10% of parking lot area Sid ewalk here m ust be 6 ' wid e Sid ewalk in R ight-of-way m ust ex tend to property line A partm ents R 2 Sid ewalk connectiv ity req uired from internal sid ewalk to sid ewalk in right-of-way C om m ercial plans to be d esigned by B uild ing D esign Professional and stam ped . N eed E nv elope C O MM check. F ire partitions to m eet req uirem ents of Section 7 08 . Penetrations in rated assem blies to m eet com ply with Section 7 14 . C oncealed spaces to be fire blocked and D raft stopped . (attic to be separated into areas no bigger than 3 000 sq uare feet or abov e ev ery two units whichev er is less.) A utom atic sprinklers req uired . L and ings at d oors and cross slope of sid ewalk not to ex ceed 2 %. D oors to m eet req uirem ents of Section 1010. Stairway s to m eet req uirem ents of Section 1011 and 1019 . H and rails and guard s to be in com pliance with 1014 and 1015 . C orrid ors to be rated and com ply with section 102 0. (egress balconies section 102 1.) E v ery resid ence to be T y pe B units. V entilation to com ply with Section 12 03 . D welling sound transm ission to be not less than 5 0, unless tested . E m ergency E scape openings as per section 103 0. SB388 DW B1233L B1233L B18L B18L SB32 DWB24L B18RB18R SB32DW B24R SB388 DW B1233L B1233L B18L B18L SB32 DWB24L B18RB18R SB32DW B24R W3024W1842R W1842R W3042 W2842 W3042 W3024 W1842LW1842L W3042W2842W3042 W3042BCW3042L BCW2442L W2742L W3024 4040LS 4040LS 4040LS 6068 4040LS 4040LS 5040LS306830686040LS 3068 6040LS 4040LS 4040LS 41168 3068 3068 3068 3068 6068 3068 3068 31168 3068 3068 5068 31168 3660 UP BB BB CC CC 22 AA AA DD DD 11 33 22X24 UNDER FLOOR ACCESS 22X24 UNDER FLOOR ACCESS DRYER VENT W/DAMPER DRYER VENT W/DAMPER DRYER VENT W/DAMPER 3'4'3'-1"4'-2"4'4'-5" 1'-10" 4' 3'-7" 2'-2" 4' 2'-5" 3'-9"6'1'-9"3'11"5"3'7"5'15'-8"12'-6"6'5'-9" 24'-3"6'-2"15'-5"24'-8" 4'-10" 4' 4'-7" 13'-5" 5'-6" 8'-7" 27'-6" 2'-11" 4' 1'-4" 8'-3" 5'-7" 9'-5" 8" 3' 7" 4'-3" 2'-7"4'2'-8" 12'-8"2'-9"9'-3"2'-11"12'-7"6'-1"10'-1"2'-5"11'-9" 70'-6" BEDROOM BATH LIVING KITCHEN BEDROOM BEDROOM CLOSET CLOSET BATH LIVING LIVING BEDROOM CLOSET CLOSET BEDROOM BATH KITCHEN KITCHEN 1 A-4 1 A-4 2 A-4 2 A-4 FIRE RISER CLOSET 22X24 UNDER FLOOR ACCESS DN SB39 DW B9LB24L B18RB18R SB32DW B24R B18L B18L SB32 DWB24L SB352132 SB362132 SB302132 B30 B30 B12L SB39 DW B9LB24L B18RB18R SB32DW B24R B18L B18L SB32 DWB24L SB352132 SB362132 SB302132 B30 B30 B12L W3024W1842R W1842R W3042 W2842 W3042 W3024 W1842LW1842L W3042W2842W3042 W942LBCW2442L BCW3142 W3642 W3024 4040LS 4040LS 6040LS 6040LS306830686040LS 4040LS 4040LS 4040LS 4040LS 4040LS 2868 2668 2068 3068 2868 6068 2868 2868 2668 6068 2668 3068 31168 5068 31168 BB BB CC CC AA AA DD DD WH WH WH DRYER VENT W/DAMPER DRYER VENT W/DAMPER 5 1/2 X 12 BEAM 6X6 POST6X6 POST6X6 POST6X6 POST6X6 POST 2'-2" 4' 2'-5" 3'4'3'-1"4'-2"4'5'-5" 1'-10" 4' 3'-7" 12'-6"6'5'-9"9'-11"6'1'-9"3'11"5"3'21'-3" 24'-3"21'-7"24'-8" 2'-11" 4' 1'-4" 8'-3" 5'-7" 9'-5" 8" 3' 7" 4'-3" 2'-7"4'2'-8" 12'-8"2'-9"9'-3"2'-11"13'-7"5'-1"10'-1"2'-5"11'-9" 70'-6" 4'-10" 4' 4'-7" 13'-5" 5'-6" 8'-7" 27'-6" 1735 SQ FT CLOSET CLOSET KITCHEN LIVING BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM LIVING LIVING BATH BATH BATH KITCHEN KITCHEN DECK CLOSET FR LIVING AREA DRYER VENT W/DAMPER REVISIONS SHEET: SCALE: DATE: 11 6/7/2023 JOB NUMBER CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG ID A-2 1st FLOOR PLAN SCALE: 1/4" = 1' 2nd FLOOR PLAN SCALE: 1/4" = 1' DRAWN BY: DAREN WARDELL 19802 VIA REDONDA RD. SONORA CA 95370 1-HR ASSEMBLIES BB CCAA DDBBCCAADD BBCC AADDBBCCAADD 2211 33221133 22 1133 25' 17'-7" 22 1133 REVISIONS SHEET: SCALE: DATE: 11 6/7/2023 JOB NUMBER CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG ID A-3 DRAWN BY: DAREN WARDELL 19802 VIA REDONDA RD. SONORA CA 95370 EXTERIOR ELEVATIONS SCALE: 1/4" = 1' APPROVED CORROSION-RESISTANT FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: 1.EXTERIOR DOOR AN WINDOW OPENINGS 2.AT THE INTERSECTION OF CHIMNEY OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS 3.UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS 4.CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIMS 5.WHERE EXTERIOR PORCHES,DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD-FRAMED CONSTRUCTION 6.AT ALL WALL AND ROOF INTERSECTIONS VINYL SIDING o/WSP COMPOSITION ROOF SHINGLES NORTH SOUTHEAST WEST 22 22 11 11 33 33 7'-5" 22 22 11 11 33 33 BB BB CC CC AA AA DD DD BB BB CC CC AA AA DD DD REVISIONS SHEET: SCALE: DATE: 11 6/7/2023 JOB NUMBER CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG ID A-4 DRAWN BY: DAREN WARDELL 19802 VIA REDONDA RD. SONORA CA 95370 SECTION 2 SCALE: 1/4" = 1' SECTION 1 SCALE: 1/4" = 1' AB ANCHOR BOLT(S) ABV ABOVE ALT ALTERNATE APPROX APPROXIMATE ARCH ARCHITECT(URAL) BLDG BUILDING BLW BELOW BM BEAM BOT BOTTOM BRG BEARING BTWN BETWEEN C.J.CONST/CONTROL JOINT CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONST CONSTRUCTION CTR CENTER DB DECK BEARING DBL DOUBLE DET DETAIL DIA DIAMETER DIM DIMENSION DN DOWN DWG DRAWING DWL DOWEL EA EACH E.F.EACH FACE E.J.EXPANSION JOINT ELEC ELECTRICAL ELEV ELEVATION EQUIP EQUIPMENT EQ EQUAL E.W.EACH WAY EXST EXISTING (E)EXISTING EXP EXPANSION EXT EXTERIOR FC-x CONTINUOUS FOOTING MARK F.D.FLOOR DRAIN FDN FOUNDATION FS-x SQUARE FOOTING MARK FT FOOT FTG FOOTING FTS-x THICKEN SLAB MARK GA GAUGE GALV GALVANIZED GLB GLULAM BEAM GSN GENERAL STRUCTURAL NOTES HB HORIZONTAL BRIDGING HORIZ HORIZONTAL HSA HEADED STUD ANCHOR HT HEIGHT IBC INTERNATIONAL BUILDING CODE I.F.INSIDE FACE IN.INCH INT INTERIOR JT JOINT JST JOIST k KIP(S) = 1000 POUNDS KLF KIPS PER LINEAL FOOT KSF KIPS PER SQUARE FOOT LBS POUNDS LF LINEAL FOOT LVL LAMINATED VENEER LUMBER MAS MASONRY MAX MAXIMUM MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS NIC NOT IN CONTRACT NTS NOT TO SCALE O.C.ON CENTER O.F.OUTSIDE FACE OPNG OPENING OPP OPPOSITE PCF POUNDS PER CUBIC FOOT PL PLATE PLF POUNDS PER LINEAL FOOT PNL PANEL PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT POINT REINF REINFORCING REQD REQUIRED R.D.ROOF DRAIN RS ROUGH SAWN LUMBER RTU ROOF TOP UNITS SCW SEISMIC CRITICAL WELD SHT SHEET SI SPECIAL INSPECTION SIM SIMILAR SMU SUSPENDED MECHANICAL UNITS SOG SLAB-ON-GRADE SQ SQUARE STAG STAGGERED STD STANDARD STL STEEL STR STRUCTURAL STS SELF TAPPING SCREWS T&B TOP AND BOTTOM TEMP TEMPERATURE THDS THREADS T.O.TOP OF TOC TOP OF CONCRETE TOD TOP OF DECK TOF TOP OF FOOTING TOS TOP OF STEEL TOW TOP OF WALL TYP TYPICAL UNO UNLESS NOTED OTHERWISE VERT VERTICAL W/WITH WD WOOD 1. TYPICAL DETAILS AND SECTIONS SHALL APPLY WHERE SPECIFIC DETAILS ARE NOT SHOWN. 2. THE CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND DIMENSIONS. IF ACTUAL CONDITIONS DIFFER FROM THOSE SHOWN IN THE CONTRACT DRAWINGS, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER BEFORE PROCEEDING WITH THE FABRICATION OR CONSTRUCTION OF ANY EFFECTED ELEMENTS. 3. THE CONTRACTOR SHALL SUBMIT A WRITTEN REQUEST TO THE ENGINEER BEFORE PROCEEDING WITH ANY CHANGES, SUBSTITUTIONS OR MODIFICATIONS. ANY WORK DONE BY THE CONTRACTOR BEFORE RECEIVING WRITTEN APPROVAL WILL BE AT THE RISK OF THE CONTRACTOR. 4. IN CASE OF A CONFLICT BETWEEN THE CONTRACT DRAWINGS AND THE SPECIFICATIONS, FOLLOW THE MOST STRINGENT REQUIREMENT OR DIRECTIONS PROVIDED BY THE ENGINEER AT NO ADDITIONAL COST TO THE OWNER. 5. THE CONTRACTOR SHALL COORDINATE WITH ALL TRADES ANY ITEMS THAT ARE TO BE INTEGRATED IN THE STRUCTURAL SYSTEM SUCH AS OPENINGS, PENETRATIONS, MECHANICAL, ELECTRICAL EQUIPMENT, ETC. SIZES AND LOCATIONS OF MECHANICAL AND OTHER EQUIPMENT THAT DIFFERS FROM THOSE SHOWN ON THE CONTRACT DRAWINGS SHALL BE REPORTED TO THE ENGINEER. 6. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING AS REQUIRED FOR HIS METHOD OF ERECTION. SHORING AND BRACING SHALL REMAIN IN PLACE UNTIL FINAL CONNECTIONS FOR THE PERMANENT MEMBERS ARE COMPLETED. THE BUILDING SHALL NOT BE CONSIDERED STABLE UNTIL ALL CONNECTIONS ARE COMPLETED. WALLS SHALL NOT BE CONSIDERED SELF-SUPPORTING AND SHALL BE BRACED UNTIL THE FLOOR/ROOF SYSTEM IS COMPLETED. 1.MATERIALS: A.FRAMING LUMBER SHALL BE # 1-2 DOUGLAS FIR-LARCH OR BETTER UNLESS NOTED OTHERWISE. B.WOOD SHEATHING SHALL BE INTERIOR GRADE WITH GLUE, SPAN INDEX RATIO, UNLESS NOTED OTHERWISE, 24/0 WALLS 48/24 ROOF C.NAILS: STANDARD COMMON WITH THE FOLLOWING PROPERTIES: NAIL SIZE SHANK DIAMETER MIN. PENETRATION INTO SUPPORT MEMBER 6D 0.113”1.25” 8D 0.131”1.50” 10D 0.148”1.63” 12D 0.148”1.63” 16D 0.162”1.75” FASTENERS OTHER THAN COMMON NAILS ARE NOT PERMITTED WITHOUT PRIOR WRITTEN APPROVAL FROM THE ENGINEER. D.BOLTS SHALL BE ASTM A36 OR EQUAL WITH ASTM A563 HEAVY HEX NUTS AND HARDENED WASHERS, GRADE A, UNLESS NOTED OTHERWISE. E. ALL LAMINATED VENEER LUMBER (LVL) SHALL BE FURNISHED BY TRUS-JOIST CORPORATION OR VERSA-LAM BY BOISE CASCADE CORPORATION. 2.ALL WOOD IN CONTACT WITH CONCRETE, MASONRY OR SOIL SHALL BE PRESSURE TREATED OR BE REDWOOD. 3.GENERAL FRAMING AND CARPENTRY SHALL BE CONNECTED AS PER “MINIMUM NAILING SCHEDULE”ON SHEET S-601 UNLESS NOTED OTHERWISE. 4.ALL FRAMING ANCHORS, POST CAPS, HOLD DOWNS, COLUMN BASES, ETC. SHALL BE PROVIDED BY SIMPSON STRONG- TIE OR APPROVED EQUAL. 5.BUILT-UP BEAMS OF 2X-MEMBER 12 IN. OR LESS IN DEPTH SHALL BE SPIKED TOGETHER WITH NOT LESS THAN 16-D SPIKES AT TWELVE-INCH (12 IN.) CENTERS, STAGGERED. IF THE DEPTH OF BEAM IS MORE THAN TWELVE INCHES (12 IN.), THE MEMBERS SHALL BE CONNECTED TOGETHER WITH 1/2" Ø BOLTS @ 24 IN. O.C. STAGGERED. BOLTS SHALL BE PLACED 1/4 THE DEPTH OF THE MEMBER FROM THE TOP AND BOTTOM OF THE MEMBER. 6.ALL WALLS SHALL HAVE A MINIMUM OF TWO TOP PLATES. SPLICES IN TOP PLATES SHALL BE STAGGERED A MINIMUM OF FOUR FEET FROM THE NEAREST SPLICE IN ADJOINING TOP PLATE. 7.ROUGH SAWN LUMBER BEAMS AND POSTS TO BE DOUGLAS FIR DENSE NO. 1 1.MATERIALS, UNLESS NOTED OTHERWISE: A.NORMAL WEIGHT AGGREGATES ASTM C33 B.REINFORCING STEEL ASTM A615 GRADE 60 (FY = 60 KSI) USE GRADE 40 (FY = 40 KSI) FOR FIELD BENT DOWELS WITH SPACINGS INDICATED REDUCED BY 1/3. C.DEFORMED BAR ANCHORS (DBA)ASTM A496 D.HEADED STUD ANCHORS (HSA)ASTM A108 E.ANCHOR RODS ASTM F1554 GRADE 36 WITH ASTM A563 HEAVY HEX NUTS WITH HARDENED WASHERS F.ADMIXTURES: I.AIR-ENTRAINING ADMIXTURES COMPLY WITH ASTM C260 (WHEN USED). II CALCIUM CHLORIDE SHALL NOT BE ADDED TO THE CONCRETE MIX. G.TYPE I/II CEMENT COMPLYING WITH ASTM C150 SHALL BE USED FOR ALL CONCRETE. H.THE WATER/CEMENT RATIOS SHALL MEET THE REQUIREMENTS OF ACI 318. I.PROVIDE AIR ENTRAINING AS RECOMMENDED BY ACI 318. J.NO ALUMINUM CONDUIT OR PRODUCT CONTAINING ALUMINUM OR ANY OTHER MATERIAL INJURIOUS TO CONCRETE SHALL BE EMBEDDED IN CONCRETE. 2.COMPRESSIVE STRENGTHS OF CONCRETE AT 28 DAYS SHALL BE AS FOLLOWS: A.FOOTINGS 3,000 PSI B.INTERIOR SLABS ON GRADE 3,000 PSI C.WALLS 3,000 PSI D.ALL SITE CONCRETE 4,000 PSI 3.ONLY ONE GRADE OR TYPE OF CONCRETE SHALL BE POURED ON THE SITE AT ANY GIVEN TIME. 4.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN, DETAILING, CARE, PLACEMENT AND REMOVAL OF ALL FORMWORK AND SHORING. A.SUPPORTING FORMS AND SHORING SHALL NOT BE REMOVED UNTIL STRUCTURAL MEMBERS HAVE ACQUIRED SUFFICIENT STRENGTH TO SAFELY SUPPORT THEIR OWN WEIGHT AND ANY CONSTRUCTION LOAD TO WHICH THEY MAY BE SUBJECTED. IN NO CASE, HOWEVER, SHALL FORMS AND SHORING BE REMOVED IN LESS THAN 24 HOURS AFTER CONCRETE PLACEMENT. 5.REINFORCEMENT SHALL HAVE THE FOLLOWING CONCRETE COVER: CAST-IN-PLACE CONCRETE:CLEAR COVER A.CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" B.FORMED CONCRETE EXPOSED TO EARTH OR WEATHER: #6 THRU #18 BARS 2" #5 AND SMALLER BARS 1-1/2" C.CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: SLABS, WALLS, JOISTS; #11 BARS AND SMALLER 3/4" BEAMS, COLUMNS: PRIMARY REINF., TIES, STIRRUPS, SPIRALS 1-1/2" 6.CONSTRUCTION JOINTS AND CONTROL JOINTS: A.PROVIDE A FORMED AND BEVELED 2 X 4 X CONTINUOUS KEYWAY IN ALL HORIZONTAL AND VERTICAL CONSTRUCTION JOINTS, UNLESS NOTED OTHERWISE. IN ADDITION, ALL JOINTS SHALL BE INTENTIONALLY ROUGHENED TO A FULL AMPLITUDE OF APPROXIMATELY 1/4-INCH. B.CONTROL JOINTS SHALL BE INSTALLED IN SLABS ON GRADE SO THE LENGTH TO WIDTH RATIO OF THE SLAB IS NO MORE THAN 1.25:1. CONTROL JOINTS SHALL BE COMPLETED WITHIN 12 HOURS OF CONCRETE PLACEMENT. CONTROL JOINTS MAY BE INSTALLED BY: I.SAW CUT A DEPTH OF 1/4 THE THICKNESS OF THE SLAB II.TOOLED JOINTS A DEPTH OF 1/4 THE THICKNESS OF THE SLAB C.INSTALL CONSTRUCTION OR CONTROL JOINTS IN SLABS ON GRADE AT A SPACING NOT TO EXCEED 30 TIMES THE SLAB THICKNESS IN ANY DIRECTION FOR UNREINFORCED SLABS AND 75 TIMES THE SLAB THICKNESS IN ANY DIRECTION FOR REINFORCED SLABS, UNLESS NOTED OTHERWISE. CONSTRUCTION JOINTS SHALL NOT EXCEED A DISTANCE OF 125'-0" O.C. IN ANY DIRECTION. 7.CONSTRUCTION A.USE CHAIRS OR OTHER SUPPORT DEVICES RECOMMENDED BY THE CRSI TO SUPPORT AND TIE REINFORCEMENT BARS AND WWF PRIOR TO PLACING CONCRETE. WWF SHALL BE CONTINUOUSLY SUPPORTED AT 36" O.C. MAXIMUM. REINFORCING STEEL FOR SLABS ON GRADE SHALL BE ADEQUATELY SUPPORTED ON PRECAST CONCRETE UNITS. LIFTING THE REINFORCING OFF THE GRADE DURING PLACEMENT OF CONCRETE IS NOT PERMITTED. B.CONCRETE TO BE MECHANICALLY CONSOLIDATED DURING PLACEMENT PER ACI STANDARDS. C.CONTRACTOR SHALL COORDINATE PLACEMENT OF ALL OPENINGS, CURBS,DOWELS, SLEEVES, CONDUITS, BOLTS, INSERTS AND OTHER EMBEDDED ITEMS PRIOR TO CONCRETE PLACEMENT. D.ALL EMBEDS AND DOWELS SHALL BE SECURELY TIED TO FORMWORK OR TO ADJACENT REINFORCING PRIOR TO THE PLACEMENT OF CONCRETE. E.NO PIPES, DUCTS, SLEEVES, ETC. SHALL BE PLACED IN STRUCTURAL CONCRETE UNLESS SPECIFICALLY DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. PENETRATIONS THROUGH WALLS WHEN APPROVED SHALL BE BUILT INTO THE WALL PRIOR TO CONCRETE PLACEMENT. PENETRATIONS WILL NOT BE ALLOWED IN FOOTINGS OR GRADE BEAMS UNLESS DETAILED. PIPING SHALL BE ROUTED AROUND THESE ELEMENTS AND FOOTINGS STEPPED TO AVOID PIPING. F.REINFORCING BARS SHALL NOT BE WELDED. DO NOT SUBSTITUTE REINFORCING BARS FOR DBAS OR HSAS. 8.DETAILING: A.LAP LENGTHS SHALL BE AS FOLLOWS: I.30 BAR DIAMETERS FOR #3 AND #4 BARS II.40 BAR DIAMETERS FOR #5 THROUGH #8 BARS III.DO NOT SPLICE STIRRUPS AND TIES. IV.DO NOT SPLICE VERTICAL BARS IN RETAINING WALLS UNLESS SPECIFICALLY SHOWN. B.AT JOINTS PROVIDE REINFORCING DOWELS TO MATCH THE MEMBER REINFORCING, UNLESS NOTED OTHERWISE. C.AT ALL DISCONTINUOUS CONTROL OR CONSTRUCTION SLAB ON GRADE JOINTS, PROVIDE 2 -#4 X 48 INCHES. D.PROVIDE CORNER BARS AT INTERSECTING WALL CORNERS USING THE SAME BAR SIZE AND SPACING AS THE HORIZONTAL WALL REINFORCING. E.ALL VERTICAL REINFORCING SHALL BE DOWELED TO FOOTINGS, OR TO THE STRUCTURE BELOW WITH THE SAME SIZE AND SPACING AS THE VERTICAL REINFORCING FOR THE ELEMENT ABOVE. DOWELS EXTENDING INTO FOOTINGS SHALL TERMINATE WITH A 90 DEGREE STANDARD HOOK AND SHALL EXTEND TO WITHIN 4" OF THE BOTTOM OF THE FOOTING. FOOTING DOWELS (#8 BARS AND SMALLER) WITH HOOKS NEED NOT EXTEND MORE THAN 20" INTO FOOTINGS. F.HORIZONTAL WALL REINFORCING SHALL TERMINATE AT ENDS OF WALLS AND OPENINGS INTO THE FAR END OF THE JAMB COLUMN WITH A 90-DEGREE STANDARD HOOK PLUS A 6 BAR DIAMETER EXTENSION. HORIZONTAL WALL REINFORCING SHALL BE CONTINUOUS THROUGH CONSTRUCTION AND CONTROL JOINTS. 1.BUILDING CODE IBC 2018 2.WIND a.3 Second Gust Velocity 90 mph b.Exposure Category B 3.SNOW a.Ground Snow Load 50 psf b.Roof Snow Load Pf = 38.5 psf min. c.Drift PER TRUSS DESIGNER U.N.O. 4.SEISMIC a.Occupancy II b.Seismic Design Category C c.Soil Site Class D d.Mapped Spectral Response Accel Ss = 0.366 e.Site Coefficients Fa= 1.507 f.Design Spectral Response Accel SDS = 0.368 g.Response Modification Factor R=6.5 h.System Overstrength Factor Ωo = 3.0 i.Deflection Amplification Factor Cd = 4 j.Seismic Response Coefficient Cs = 4.0*SDS*Ie/R = 0.057 k.W Dead Load of Structure l.Base Shear V = Cs*W = 0.057 W 5.ROOF LOAD a.Live Load 20 psf b.Dead Load 15 psf 6.FLOOR LOAD a.Live Load 40 psf b.Dead Load 15 psf SPECIAL INSPECTION AND QUALITY ASSURANCE SPECIAL INSPECTION AND QUALITY ASSURANCE, AS REQUIRED BY SECTION 1704 OF THE IBC, SHALL BE PROVIDED BY AN INDEPENDENT AGENCY EMPLOYED BY THE OWNER UNLESS WAIVED BY THE BUILDING OFFICIAL. THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE REQUIRED INSPECTIONS. ALL TESTING AND INSPECTION REPORTS SHALL BE SENT TO THE ENGINEER FOR REVIEW. ITEMS REQUIRING SPECIAL INSPECTION AND QUALITY ASSURANCE ARE: 1. CONCRETE FORMWORK (IBC SECTION 1705.3-12),IF NOTED 2. CONCRETE REINFORCING STEEL PLACEMENT (IBC SECTION 1705.3-1),IF NOTED 3. INSTALLATION OF GLULAM BEAM END CONNECTIONS AND POST CONNECTIONS 4. EPOXY ANCHORS (IBC SECTION 1705.3-4) DEFERRED SUBMITTALS FOR THE PURPOSE OF THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS PER SECTION 106.3.4.2 OF THE IBC. SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE ENGINEER/ARCHITECT FOR THEIR REVIEW FOR GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING. DEFERRED STRUCTURAL SUBMITTALS FOR THIS PROJECT ARE: 1.WOOD ROOF TRUSS 1 2 3 4 5 1 2 3 4 5 D C B A D C B A 1712 CABALLERO DR. AMMON, IDAHO 83406 (208) 932-2720 WWW.NOESIS.US DRAWN BY DATE DESIGNED BY DATE CHECKED BY DATE AL W A Y S T H I N K SA F E T Y NOESIS ENGINEERING SERVICES, P.C. THIS DOCUMENT WAS ELECTRONICALLY SIGNED. THE DIGITAL CERTIFICATE IS IDENTIFIED ON THE 1ST PAGE OF THE ORIGINAL FILE. THE ORIGINAL DOCUMENT IS LOCATED AT NOESIS ENGINEERING SERVICES, PC HOME OFFICE SERVER UNDER THE JOB NUMBER FOLDER/7.0 ORIGINAL DOCUMENTS. DKB 6/5/2023 9:39:36 AM 6/5/2023 9:39:36 AM 6/5/2023 9:39:36 AM GENERAL STRUCTURAL NOTES S-001 CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG, ID 83440 DA R E N W A R D R E L L CO R C O R A N 6 U N I T 22 0 3 1 -RE V 2 JL JL DAREN WARDRELL 1 ABRIVIATIONS 2 GENERAL NOTES 3 WOOD NOTES 5 CONCRETE NOTES 6 DESIGN CRITERIA 4 STATEMENT OF SPECIAL INSPECTIONS No. Description Date 06/05/2023 R oof snow load 3 5 . F rost d epth 3 6 ". D 1 3 42 A B C 4' - 3 " 9' - 1 0 " 13 ' - 5 " 27 ' - 6 " D J1 CW-6 CW-6 CW-6 CW-6 CW-6 CW-6 BOT. TO FROST DEPTH FC1.5 BOT. TO FROST DEPTH FC1.3 BOT. TO FROST DEPTH FC1.5 BOT. TO FROST DEPTH FC1.3 BOT. TO FROST DEPTH FC1.5 BOT. TO FROST DEPTH FC1.3 BOT. TO FROST DEPTH FC1.5 4" SLAB ON GRADE, SEE ARCH PLANS 3/4" MINUS CRUSHED AGGREGATE BASE (4" MIN.) COMPACTED TO 95% MODIFIED PROCTOR COMPACTED NATURAL GRADE OR STRUCTURAL FILL COMPACTED TO 95% MODIFIED PROCTOR IN 12" MAX LIFTS 2X4 PONY WALL 2X4 PONY WALL 2X4 PONY WALL BOT. TO FROST DEPTH FC1.5 BOT. TO FROST DEPTH FC1.5 BOT. TO FROST DEPTH FC1.5 2X4 PONY WALL BOT. TO FROST DEPTH FC1.5 2X4 PONY WALL 8" CONC. COL 8" CONC. COL 8" CONC. COL 8" CONC. COL 8" CONC. COL BOT. TO FROST DEPTH FS3.0 BOT. TO FROST DEPTH FS3.0 BOT. TO FROST DEPTH FS3.0 BOT. TO FROST DEPTH FS3.0 BOT. TO FROST DEPTH FS3.0 3 S-501 Typ HD-1 HD-1 HD-1 HD-1 5 S-510 Typ 5 S-510 Typ 70' - 6" 24' - 3"9' - 3"9' - 3"9' - 3"7' - 6"7' - 6"3' - 6" 14 ' - 1 " 1' - 6 " 11 ' - 6 " 1' - 6 " 12 ' - 6 " 1' - 6 " 14 ' - 3 " 11 ' - 6 " 10 ' - 5 1 / 4 " 12 ' - 9 3 / 4 " 11 ' - 9 " 13 ' - 3 " 1' - 6 " 10 ' - 0 " 1' - 6 " 9' - 9 " 1' - 6 " 1' - 4"23' - 7"21' - 1"12' - 2 1/2"3' - 11"7' - 10 1/2"1' - 4" 1' - 4"23' - 1" 6"6"5" 12' - 1 1/2"1' - 11 1/2"9' - 5"1' - 4" 1' - 6 " 8' - 1 1 3 / 4 " 1' - 6 " 2' - 6 " 1' - 6 " 6' - 9 1 / 4 " 1' - 6 " 1' - 6 " 11 ' - 0 3 / 4 " 1' - 6 " 8' - 8 1 / 4 " 1' - 6 " 2 3 / 4 " 4' - 0 1 / 4 " 3' - 0 " 2' - 6 1 / 4 " CW-6 CW-6 BOT. TO FROST DEPTH FC1.3 BOT. TO FROST DEPTH FC1.3 SECTION MARK SHEET NUMBER MARKS AND SYMBOLS LEGEND CW-X INDICATES CONC. WALL, SEE SCH ON S-601 F__X_INDICATES FOOTING AND TOP OF CONC. FOOTING (TOC), SEE PLAN AND SCH. ON S-601 *NOTE* VERIFY TOP OF CONC. ELEVATIONS WITH ARCH PLANS AND FIELD VERIFY FROST DEPTH (36"). TOC ____ HD-X HOLD DOWN, SEE SCH ON S-601 FOUNDATION PLAN NOTES 1. VERIFY ALL FLOOR OPEINGS FOR MECHANICAL SHAFTS, STAIRS, ETC. WITH ARCHITECTURAL AND MECHANICAL DRAWINGS. 2. SEE ARCHITECTURAL DRAWINGS FOR COLUMN WALLS AND OPENING DIMENSIONS. 3. FIELD VERIFY ALL DIMENSIONS. 4. ARCHITECT TO VERIFY REQUIRED BEAM CLEARANCE 5. COORDINATE LOCATION OF DEPRESSED SLABS, SLOPED SLABS, AND FLOOR DRAINS ARCHITECTURAL AND MECHANICAL DRAWINGS. 6. SEE ARCHITECTURAL AND CIVIL DRAWINGS FOR EXTERIOR CONCRETE WORK AT DOORS, SIDEWALKS, ETC. 7. SEE ARCHITECTURAL DRAWINGS FOR CONTROL JOINT LOCATION. 8. ALL SPOT FOOTINGS SHALL BE CENTERED UNDER COLUMNS (UNO). 9. SEE DETAILS 1&2/S-501 FOR CONDITION WHERE BURIED PIPES RUN PARALLEL AND PERPENDICULAR TO FOOTINGS. 10. SEE DETAIL 5/S-601 FOR SLAB REINFORCING WHERE CONTROL JOINTS ARE DISCONTINUOUS. 11. SEE DETAIL 6/S-601 FOR ADDITIONAL REINFORCING AT MISCELLANEOUS OPENINGS IN CONCRETE WALLS. 12. SEE DETAIL 7/S-601 FOR TYPICAL CONTROL/CONSTRUCTION JOINTS IN CONCRETE SLAB ON GRADE. 13. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS FOR ALL WALLS AND OPENINGS. 14. ALL EXTERIOR WALLS TO BE 2X6 DF. NO. 2 STUDS @ 16" O.C. U.N.O. 15. SEE 3/S-501 FOR CONCRETE COLUMN REBAR CONFIGURATION FRAMING PLAN NOTES 1. VERIFY ALL FLOOR OPEINGS FOR MECHANICAL SHAFTS, STAIRS, ETC. WITH ARCHITECTURAL AND MECHANICAL DRAWINGS. 2. SEE ARCHITECTURAL DRAWINGS FOR COLUMN WALLS AND OPENING DIMENSIONS. 3. FIELD VERIFY ALL DIMENSIONS. 4. ARCHITECT TO VERIFY REQUIRED BEAM CLEARANCE 5. SEE 6/S-602 FOR TOP PLATE SPLICE AND 1/S-520 AT PIPES. FLOOR SCHEDULE 9-1/2" TJI 110 AT 16" O.C. W/ SIMPSON ITS1.81/9.5 HANGERS WHERE APPLICABLE J1 2' - 0 " 1' - 6" 1-3/4" X 9-1/2" LVL WITH SIMPSON ITS1.81/9.5 FRAMING AROUND CRAWL SPACE 13 ' - 6 " M A X . S P A N 1 2 3 4 5 1 2 3 4 5 D C B A D C B A 1712 CABALLERO DR. AMMON, IDAHO 83406 (208) 932-2720 WWW.NOESIS.US DRAWN BY DATE DESIGNED BY DATE CHECKED BY DATE AL W A Y S T H I N K SA F E T Y NOESIS ENGINEERING SERVICES, P.C. THIS DOCUMENT WAS ELECTRONICALLY SIGNED. THE DIGITAL CERTIFICATE IS IDENTIFIED ON THE 1ST PAGE OF THE ORIGINAL FILE. THE ORIGINAL DOCUMENT IS LOCATED AT NOESIS ENGINEERING SERVICES, PC HOME OFFICE SERVER UNDER THE JOB NUMBER FOLDER/7.0 ORIGINAL DOCUMENTS. DKB 6/5/2023 9:39:40 AM 6/5/2023 9:39:40 AM 6/5/2023 9:39:40 AM MAIN FLOOR FRAMING AND FOUNDATION PLAN S-101 CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG, ID 83440 DA R E N W A R D R E L L CO R C O R A N 6 U N I T 22 0 3 1 -RE V 2 JL JL DAREN WARDRELL 3/8" = 1'-0"1 FOUNDATON PLAN No. Description Date 1 REV 1- FOUNDATION CHANGE TO CRAWL SPACE 4/19/2023 2 REV 2- BUILDING LAYOUT 05/31/2023 2 3 CRAWL SPACE ACCESS DETAIL 1 06/05/2023 1 3 42 A B C D 3 S-510 Typ 2 S-510 Typ 4 S-510 Typ 27 ' - 6 " J1 J2 C-1 C-2 C-2 C-2 2X4 BEARING WALL AT 16" O.C. 2X4 BEARING WALL AT 16" O.C. 2X4 BEARING WALL AT 16" O.C. 2X4 BEARING WALL AT 16" O.C. 2X6 BEARING WALL AT 16" O.C. WH -1 WH-3 WH -1 WH -1 WH-3 WH-1 WH-1 WH-3 WH -1 WH -1 WH-3WH-1 WH-1WH-1 5 S-520 Typ BM-1 BM-1 BM-1 C-2 C-2 SW- 3 SW- 1 SW- 1 SW- 1 SW- 1 SW- 3 WH-1 1 S-510 Typ MSTC28_16 SIMPSON STRAP MSTC28_16 SIMPSON STRAP MSTC28_18 SIMPSON STRAP MSTC28_18 SIMPSON STRAP GALVANIZED OR PAINTED C10X15.3 STAIR STRINGERBM -2 C-1 SIMPSON HUC612TF CONCEALED HANGERS-510 6 Typ WH-1 WH-1 12 ' - 4 1 / 2 " WH-1 WH-1 SECTION MARK SHEET NUMBER MARKS AND SYMBOLS LEGEND SW-x INDICATES SHEAR WALL TYPE, SEE S-602 HD-X HOLD DOWN, SEE SCH ON S-601 WH-X INDICATES HEADER, KING AND BEARING STUDS @ OPENING SEE SCH S-602 FRAMING PLAN NOTES 1. VERIFY ALL FLOOR OPEINGS FOR MECHANICAL SHAFTS, STAIRS, ETC. WITH ARCHITECTURAL AND MECHANICAL DRAWINGS. 2. SEE ARCHITECTURAL DRAWINGS FOR COLUMN WALLS AND OPENING DIMENSIONS. 3. FIELD VERIFY ALL DIMENSIONS. 4. ARCHITECT TO VERIFY REQUIRED BEAM CLEARANCE 5. SEE 6/S-602 FOR TOP PLATE SPLICE AND 1/S-520 AT PIPES. LOADING ASSUMPTIONS FLOOR DEAD LOAD 15 PSF FLOOR LIVE LOAD 40 PSF ROOF DEAD LOAD 15 PSF ROOF SNOW LOAD 38.5 PSF GROUND SNOW LOAD 50 PSF DRIFT BY TRUSS DESIGNER ROOF LIVE LOAD 20 PSF COLUMN AND BEAM SCHEDULE BEAMS BM-1 P.T. 6X8 DF #2 OR BETTER BM-2 6X12 DF #2 OR BETTER COLUMNS C-1 (3) 2X6 DF #2 OR BETTER C-2 6X6 DF #2 OR BETTER FLOOR SCHEDULE 9-1/2" TJI 110 AT 16" O.C. W/ SIMPSON ITS1.81/9.5 HANGERS WHERE APPLICABLE J1 SW-x INDICATES SHEAR WALL TYPE, SEE S-602 BM-X INDICATES BEAM, SEE COLUMN AND BEAM SCHEDULE C-X INDICATES BEAM, SEE COLUMN AND BEAM SCHEDULE P.T. 2X6 DF#2 OR BETTER AT 16" O.C. W/ SIMPSON LU26 HANGERS OR EQUAL J2 1 2 3 4 5 1 2 3 4 5 D C B A D C B A 1712 CABALLERO DR. AMMON, IDAHO 83406 (208) 932-2720 WWW.NOESIS.US DRAWN BY DATE DESIGNED BY DATE CHECKED BY DATE AL W A Y S T H I N K SA F E T Y NOESIS ENGINEERING SERVICES, P.C. THIS DOCUMENT WAS ELECTRONICALLY SIGNED. THE DIGITAL CERTIFICATE IS IDENTIFIED ON THE 1ST PAGE OF THE ORIGINAL FILE. THE ORIGINAL DOCUMENT IS LOCATED AT NOESIS ENGINEERING SERVICES, PC HOME OFFICE SERVER UNDER THE JOB NUMBER FOLDER/7.0 ORIGINAL DOCUMENTS. DKB 6/5/2023 9:39:44 AM 6/5/2023 9:39:44 AM 6/5/2023 9:39:44 AM SECOND FLOOR FRAMING PLAN S-102 CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG, ID 83440 DA R E N W A R D R E L L CO R C O R A N 6 U N I T 22 0 3 1 -RE V 2 JL JL DAREN WARDRELL 3/8" = 1'-0"1 SECOND FLOOR FRAMING PLAN No. Description Date 2 REV 2- BUILDING LAYOUT 05/31/2023 2 06/05/2023 1 3 42 A B C D WH-1 WH-1 WH -1 SW- 1 SW- 3 SW- 3R1 2 S-520 Typ 4 S-520 Typ 3 S-520 TYP 3 S-520 TYP 1' - 4 " 1' - 4" C-1 C-2 C-2 C-2 C-2 C-2 WH-1 WH-2 WH -1 WH -1 WH-2 WH-1 WH-1 WH-2 WH -1 SW- 1 SW- 1 SW- 1 WH -1 BM-2 BM-2 BM-2 BM-2 BM-2 5 S-520 Typ SECTION MARK SHEET NUMBER MARKS AND SYMBOLS LEGEND INDICATES WOOD SHEATHING. SEE GSN AND SCHEDULE ON SHEET S-602 SW-x INDICATES SHEAR WALL TYPE, SEE S-602 HD-X HOLD DOWN, SEE SCH ON S-601 WH-X INDICATES HEADER, KING AND BEARING STUDS @ OPENING SEE SCH S-602 FRAMING PLAN NOTES 1. VERIFY ALL FLOOR OPEINGS FOR MECHANICAL SHAFTS, STAIRS, ETC. WITH ARCHITECTURAL AND MECHANICAL DRAWINGS. 2. SEE ARCHITECTURAL DRAWINGS FOR COLUMN WALLS AND OPENING DIMENSIONS. 3. FIELD VERIFY ALL DIMENSIONS. 4. ARCHITECT TO VERIFY REQUIRED BEAM CLEARANCE 5. SEE 6/S-602 FOR TOP PLATE SPLICE AND 1/S-520 AT PIPES. LOADING ASSUMPTIONS ROOF DEAD LOAD 15 PSF ROOF SNOW LOAD 38.5 PSF GROUND SNOW LOAD 50 PSF DRIFT BY TRUSS DESIGNER ROOF LIVE LOAD 20 PSF ROOF SCHEDULE ROOF TRUSSES BY OTHERSR1 COLUMN AND BEAM SCHEDULE BEAMS BM-1 P.T. 6X8 DF #2 OR BETTER BM-2 6X12 DF #2 OR BETTER COLUMNS C-1 (3) 2X6 DF #2 OR BETTER C-2 6X6 DF #2 OR BETTER 1 2 3 4 5 1 2 3 4 5 D C B A D C B A 1712 CABALLERO DR. AMMON, IDAHO 83406 (208) 932-2720 WWW.NOESIS.US DRAWN BY DATE DESIGNED BY DATE CHECKED BY DATE AL W A Y S T H I N K SA F E T Y NOESIS ENGINEERING SERVICES, P.C. THIS DOCUMENT WAS ELECTRONICALLY SIGNED. THE DIGITAL CERTIFICATE IS IDENTIFIED ON THE 1ST PAGE OF THE ORIGINAL FILE. THE ORIGINAL DOCUMENT IS LOCATED AT NOESIS ENGINEERING SERVICES, PC HOME OFFICE SERVER UNDER THE JOB NUMBER FOLDER/7.0 ORIGINAL DOCUMENTS. DKB 6/5/2023 9:39:47 AM 6/5/2023 9:39:47 AM 6/5/2023 9:39:47 AM ROOF FRAMING PLAN S-103 CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG, ID 83440 DA R E N W A R D R E L L CO R C O R A N 6 U N I T 22 0 3 1 -RE V 2 JL JL DAREN WARDRELL 3/8" = 1'-0"1 ROOF FRAMING PLAN No. Description Date 2 REV 2- BUILDING LAYOUT 05/31/2023 2 06/05/2023 BACK-FILLED TRENCH PIPE, SEE CIVIL BOTTOM OF TRENCH SHALL BE ABOVE THIS LINE CONCRETE FOOTING, SEE PLAN AND SCHED 1 2 2'-0" MIN 6" PIPE PASSES THROUGH FOOTING PIPE PASSES BELOW FOOTING 1/2" CLEAR 6" MI N IF D I M E N S I O N E X C E E D S 1' -6" , U S E T Y P I C A L FO O T I N G S T E P 1/2" CLEAR 24 BAR DIAMETERS 6" MI N 2" C L E A R 12" MIN 12" MIN 12" MIN12" MIN INTERRUPT CONT FTG REINF FOR PASSAGE OF PIPE ADDITIONAL REINF TO MATCH CONT FTG REINF PIPE, SEE MECH. PROVIDE SLEEVES AROUND ALL PIPES PASSING THROUGH WALL AND FOOTINGS CONCRETE FOOTING, SEE PLAN AND SCH ADDITIONAL REINF TO MATCH CONT FTG REINF PIPE, SEE MECH. PROVIDE SLEEVES AROUND ALL PIPES PASSING THROUGH WALL AND FOOTINGS CONCRETE FOOTING, SEE PLAN AND SCH #5 X CONT BAR CONCRETE SLAB ON GRADE, SEE PLAN CONCRETE FOOTING, SEE PLAN AND SCHED 8" WALL BEYOND FIELD BEND VERT WALL REINFORCING INTO SLAB (3) #3 TIES AT 3" O.C. AND 10" O.C. REMAINDER FOOTING PER PLAN AND SCH CONC. COL PER PLAN WITH (4) #5 VERTICAL REBAR BENT INTO FOOTING 6X6 DF #2 OR BETTER WOOD COLUMN SIMPSON PBS66 POST BASE 2x6 @ 16" O.C. (SEE PLAN) S.N. SHEATHING PER PLANB.N. E.N.JOIST PER PLAN "ITS" HGR P.T. 2x SILL PL MATCH CONC. WALL WIDTH w/ 5/8" DIA. x10" ANCHOR BOLT SEE SCHEDULE AND PLAN 3" NATIVE SOIL OR COMPACTED TO 95% MOD. PROCTOR, UNLESS OTHERWISED NOTED IN GEOTECH REPORT PE R A R C H PE R A R C H CR A W L S P A C E CONC. WALL PER PLAN BEND CONCRETE VERT. REBAR INTO FOOTING MAT FOOTING PER PLAN PE R A R C H CR A W L S P A C E FI E L D V E R I F Y FR O S T D E P T H 2x6 @ 16" O.C. (SEE PLAN) S.N. SHEATHING PER PLANB.N. E.N.JOIST PER PLAN P.T. 2x SILL PL MATCH CONC. WALL WIDTH w/ 5/8" DIA. x10" ANCHOR BOLT SEE SCHEDULE AND PLAN CONC. WALL PER PLAN 3" NATIVE SOIL OR COMPACTED TO 95% MOD. PROCTOR, UNLESS OTHERWISED NOTED IN GEOTECH REPORT PE R A R C H TJI BLK'G @ 48" O/C/ W "ITS" HGR BEND CONCRETE VERT. REBAR INTO FOOTING MAT FOOTING PER PLAN PE R A R C H CR A W L S P A C E FI E L D V E R I F Y FR O S T D E P T H TYP 3" WALL ABV WHERE OCCURS, SEE PLAN FLOOR SHEATHING, SEE PLAN AND SCHEDULE FLOOR JOIST, SEE PLAN TY P 3" CONC FOOTING, SEE PLAN AND SCHEDULE 1/2" DIA X 10" J BOLT @ 48" O.C. 2X4 STUD PONY WALL @ 24" O.C. 2X TREATED SILL PLATE FULL HEIGHT JOIST BLOCKING ABV ALL PONY WALLS 1 2 3 4 5 1 2 3 4 5 D C B A D C B A 1712 CABALLERO DR. AMMON, IDAHO 83406 (208) 932-2720 WWW.NOESIS.US DRAWN BY DATE DESIGNED BY DATE CHECKED BY DATE AL W A Y S T H I N K SA F E T Y NOESIS ENGINEERING SERVICES, P.C. THIS DOCUMENT WAS ELECTRONICALLY SIGNED. THE DIGITAL CERTIFICATE IS IDENTIFIED ON THE 1ST PAGE OF THE ORIGINAL FILE. THE ORIGINAL DOCUMENT IS LOCATED AT NOESIS ENGINEERING SERVICES, PC HOME OFFICE SERVER UNDER THE JOB NUMBER FOLDER/7.0 ORIGINAL DOCUMENTS. DKB 6/5/2023 9:39:51 AM 6/5/2023 9:39:51 AM 6/5/2023 9:39:51 AM FOUNDATION DETAILS S-501 CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG, ID 83440 DA R E N W A R D R E L L CO R C O R A N 6 U N I T 22 0 3 1 -RE V 2 JL JL DAREN WARDRELL 1 CONDITION AT PIPE PARALLEL TO CONCRETE FOOTING 2 CONDITION AT PIPE PERP. TO CONC. FTG. 4 CONCRETE FOUNDATION AT WOOD WALL OPENING 3 CONCRETE COLUMN No. Description Date 5 FOUNDATION WALL @ DROPPED JOIST I 6 FOUNDATION WALL @ DROPPED JOIST II 7 PONY WALL DETAIL 06/05/2023 FLOOR BOUNDARY NAILING FLOOR SHEATHING, SEE PLAN WOOD JOIST, SEE PLAN CONTINUOUS RIM SHEARWALL EDGE NAILING DOUBLE TOP PLATE BOARD WALL ABOVE, WHERE OCCURS, SEE PLAN WOOD STUD WALL, SEE PLAN WALL SHEATHING, SEE PLAN SIMPSON 'A34' AT 24" O.C. SIMPSON HANGER FLOOR BOUNDARY NAILING FLOOR SHEATHING, SEE PLAN WOOD JOIST, SEE PLAN CONTINUOUS RIM SHEARWALL EDGE NAILING DOUBLE TOP PLATE BOARD WALL ABOVE, WHERE OCCURS, SEE PLAN WOOD I-JOIST BLOCK AT 48" O.C. WOOD STUD WALL, SEE PLAN WALL SHEATHING, SEE PLAN SIMPSON 'A34' AT 24" O.C. WOOD JOIST, SEE PLAN FLOOR SHEATHING, SEE SCHEDULE FULL HEIGHT JOIST BLOCKING BETWEEN EACH JOIST FLOOR BOUNDARY NAILING, SEE SCHEDULE 16d NAIL AT 6" O.C. DOUBLE TOP PLATE WALL FINISH, SEE ARCH HEADER WHERE OCCURS, SEE PLAN WOOD STUD WALL, SEE PLAN BEAM, SEE PLAN WOOD COL, SEE PLAN SIMPSON PC6Z POST CAPS IF BEAM IS SPLIT AT COLUMN, BEAM END/BEGINNING SHALL OCCUR AT THE CENTER OF COLUMN NOTE: LENGTH OF THICKENED SLAB = DISTANCE BETWEEN STAIR STRINGER + 12" GALVANIZED C10X15.3 STAIR STRINGER (2) #4 BARS x CONT. 1' - 4" 6" 1/2" PLATE ALL SIDES(2) SIMPSON 3/4"Ø x 6.5" TITEN HD OR 3/4"Ø F1554 ALL-THREAD WITH SIMPSON SET-XP EPOXY GALVANIZED C10X15.3 STRINGERS METAL STAIR TREAD WITH (2) 1/2" DIA. BOLTS HANDRAIL PER ARCH PLANS SEE 2/S-505 FOR THICKENED SLAB AT STAIR P.T. 6X12 BEAM P.T. FLOOR JOISTS PER PLAN FLOOR SHEATHING PER PLAN 3/8" PLATE WITH (3) 5/8" BOLTS PROFILE VIEW SECTION A-A 2 1 / 2 " 2 1 / 2 " STAIR TREND WIDTH 3' - 3 1/2" A A ALL SIDES 1/4 3-1/2" X 11-1/2" X 3/8" GALVANIZED PLATE WITH (3) 5/8" BOLTS GALVANIZED C10X15.3 STRINGERS P.T. 6X12 BEAM 3 1/2" 11 1 / 2 " 3" CARRIER PLATE C, 2 - 1 / 4 " D, 3 / 4 " G, 4"F, 7"E, 1-1/8" A, 3 " GRATING NOSING B, 12-1/8" 1-7/16" X 7/16" SLOT 7/16" DIA. BOLT HOLE A, HEIGHT OF CARRIER PLATE B, WIDTH OF CARRIER PLATE C, CENTER OF 1-7/16" X 7/16" SLOT AND CENTER OF 7/16" DIAMETER BOLT HOLE TO TOP EDGE OF CARRIER PLATE / SURFACE OF STAIR TREAD D, CENTER OF 1-7/16" X 7/16" SLOT AND CENTER OF 7/16" DIAMETER BOLTH HOLE TO BOTTOM EDGE OF CARRIER PLATE E, CENTER OF 7/16" DIAMETER BOLT TO NEAREST EDGE OF CARRIER PLATE HEIGHT F, CENTER 1-7/16" X 7/16" SLOT TO CENTER OF 7/16" DIAMETER BOLT HOLE G, CENTER OF 1-7/16" X 7/16" SLOT TO NEAREST EDGE OF CARRIER PLATE HEIGHT STEEL BB HGT, 1-1/2" -2-1/2" ALUM BB HGT, 1"-2-1/2" NOSING WIDTH, 1-1/4" GRATING WIDTH, 10-7/8" NO. OF BB, 10 TREAD WIDTH, 12-1/8" CARRIER PLATE NO., CP-BG-1230 STAIR TREAD AND CARRIER PLATE END VIEW 1 2 3 4 5 1 2 3 4 5 D C B A D C B A 1712 CABALLERO DR. AMMON, IDAHO 83406 (208) 932-2720 WWW.NOESIS.US DRAWN BY DATE DESIGNED BY DATE CHECKED BY DATE AL W A Y S T H I N K SA F E T Y NOESIS ENGINEERING SERVICES, P.C. THIS DOCUMENT WAS ELECTRONICALLY SIGNED. THE DIGITAL CERTIFICATE IS IDENTIFIED ON THE 1ST PAGE OF THE ORIGINAL FILE. THE ORIGINAL DOCUMENT IS LOCATED AT NOESIS ENGINEERING SERVICES, PC HOME OFFICE SERVER UNDER THE JOB NUMBER FOLDER/7.0 ORIGINAL DOCUMENTS. DKB 6/5/2023 9:41:17 AM 6/5/2023 9:41:17 AM 6/5/2023 9:41:17 AM FLOOR FRAMING DETAILS S-510 CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG, ID 83440 DA R E N W A R D R E L L CO R C O R A N 6 U N I T 22 0 3 1 -RE V 2 JL JL DAREN WARDRELL 2 WOOD FLOOR BEARING PERP. TO EXT. WOOD STUD WALL 3 WOOD FLOOR BEARING PARRALLEL TO EXT. WOOD STUD WALL 4 WOOD FLOOR BEARING AT INTERIOR WOOD STUD WALL1WOOD BEAM @ WOOD COLUMN No. Description Date 5 THICKENED SLAB AT STAIR 6 STAIR DETAIL1 7 CP-BG-1230 BAR GRATING END PLATE 06/05/2023 TOP PLATE SPLICE CL SIMPSON STRAP EACH SIDE DOUBLE TOP PLATE PIPE AND STRAP TYP WALL STUDS VERIFY SIZE AND LOCATION WITH ARCH, MECH, AND ELECTRICAL DRAWINGS HOLE SIZE STRAPS NONE REQUIRED ST2122 WITH (4) 16d NAILS EACH END ST2215 WITH (6) 16d NAILS EACH END GREATER THAN STUD WIDTH GREATER THAN 1/3 AND LESS THAN OR EQUAL TO 2/3 STUD WIDTH LESS THAN OR EQUAL TO 1/3 STUD WIDTH PRE-FABRICATED WOOD TRUSS SIMPSON 'H2.5' AT EACH TRUSS AND (3) 16d NAILS DOUBLE TOP PLATE WOOD STUD WALL, SEE PLAN PLYWOOD SHEAR WALL (WHERE OCCURS, SEE PLAN) EDGE NAILING, SEE PLAN 2x CONT FACIA BOARD, SEE ARCH ROOF SHEATHING, SEE PLAN ROOF BOUNDARY NAILING, IN SOLID FULL HEIGHT BLOCKING, SEE PLAN 2X FACIA BOARD, SEE ARCH ROOF EDGE NAIL, SEE SCH ROOF EDGE NAIL INTO SOLID BLOCKING SIMPSON LUS24 INSTALLED UPSIDE DOWN 2X4 OUTLOOKER @ 24" O.C., CONTINUOUS OVER GABLE, TYP SIMPSON H1 @ EA OUTLOOKER WALL SHEATHING, SEE PLAN & SCH WALL SHEATHING EDGE NAIL, SEE PLAN & SCH WALL TOP PLATE, SEE DETAIL WOOD HEADER WHERE OCCURES, SEE PLAN WOOD WALL, SEE PLAN ROOF SHEATHING, SEE SCH 2X BLOCK @ WALL BRACE 1 1 MIN SIMPSON A34 @24" O.C. 2X4 KICKER @ 4'-0" CENTERS W/ (3) 16d NAILS EA END AND (2) 16d NAILS @ INTERMEDIATE TRUSSES SOLID BLOCKING ABV BEAM W/ PLYWOOD SHIMS AS RQRD FLOOR SHEATING PER PLAN P.T. 6X8 WOOD BEAM CONNECTED TO COLUMN WITH SIMPSON HUC66 OR SIMPSON CJT3Z WOOD WALL, SEE PLAN 6X6 DF #2 OR BETTER COLUMN S-501 3 Typ S-501 5 Sim CONCRETE SLAB ON FLOOR JOIST PER PLAN FLOOR SHEATING PER PLAN FLOOR JOIST PER PLAN P.T. 2X6 DF#2 OR BETTER AT 16" O.C. W/ SIMPSON LU26 HANGERS OR EQUAL S-510 2 Typ P.T. 2X6 DF#2 LEDGER, CONNECTED TO BUILDING WITH (2) SIMPSON SDWS TIMBER SCRES EXTERIOR GRADE SDWS22400DB @ 16" O.C. PRE-FABRICATED WOOD TRUSS P.T. 6X8 WOOD BEAM CONNECTED TO COLUMN WITH SIMPSON HUC66 OR SIMPSON CJT3Z 6X12 WOOD BEAM, CONNECTED TO IN-WALL COLUMN WITH SIMPSON HUC612 OR SIMPSON CJT3Z, CONNECTED TO POST WITH SIMPSON PC6Z S-510 1 Typ S-520 4 Typ S-520 2 Typ PRE-FABRICATED WOOD TRUSS SIMPSON 'H2.5' AT EACH TRUSS AND (3) 16d TOENAILS WOOD BEAM 2x CONT FACIA BOARD, SEE ARCH ROOF SHEATHING, SEE PLAN ROOF EDGE NAILING, IN SOLID FULL HEIGHT BLOCKING, SEE PLAN SIMPSON A35 @ 24"O.C. 1 2 3 4 5 1 2 3 4 5 D C B A D C B A 1712 CABALLERO DR. AMMON, IDAHO 83406 (208) 932-2720 WWW.NOESIS.US DRAWN BY DATE DESIGNED BY DATE CHECKED BY DATE AL W A Y S T H I N K SA F E T Y NOESIS ENGINEERING SERVICES, P.C. THIS DOCUMENT WAS ELECTRONICALLY SIGNED. THE DIGITAL CERTIFICATE IS IDENTIFIED ON THE 1ST PAGE OF THE ORIGINAL FILE. THE ORIGINAL DOCUMENT IS LOCATED AT NOESIS ENGINEERING SERVICES, PC HOME OFFICE SERVER UNDER THE JOB NUMBER FOLDER/7.0 ORIGINAL DOCUMENTS. DKB 6/5/2023 9:40:04 AM 6/5/2023 9:40:04 AM 6/5/2023 9:40:04 AM ROOF FRAMING DETAILS S-520 CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG, ID 83440 DA R E N W A R D R E L L CO R C O R A N 6 U N I T 22 0 3 1 -RE V 2 JL JL DAREN WARDRELL 1 TOP PLATE SPLICE AT PIPE 2 WOOD TRUSS BEARING AT WOOD STUD WALL 3 GABLE END FRAMING 5 SECTION VIEW OF FRONT PORCH AND SECOND FLOOR No. Description Date 4 WOOD TRUSS BEARING AT WOOD BEAM 06/05/2023 MARK MAX. DESIGN LOAD @ T.O.F. No.SIZE LENGTH SPACING REINFORCING CROSSWISE REINFORCING LENGTHWISE No.SIZE LENGTH SPACING FS2.5 7,500 LB3#4 EQ FS2.75 9,075 LB3#4 EQ FS1.5 2,700 LBEQ CONCRETE FOOTING NOTES: 1. COMPRESSIVE STRENGTHS OF CONCRETE AT 28 DAYS SHALL BE 3,000 PSI 2. PLACE ALL FOOTING REINFORCING IN THE BOTTOM OF THE FOOTING WITH 3" CLEAR CONCRETE COVER (UNO). 3. TOP REINFORCING, WHERE OCCURS, SHALL BE PLACED IN THE TOP OF THE FOOTING WITH 2" MINIMUM CONCRETE COVER. 4. IF FOOTINGS ARE EARTH-FORMED, FOOTINGS SHALL BE 6" LONGER AND WIDER THAN SCHEDULED. 5. SEE GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS. 6. SOME SCHEDULED FOOTINGS MAY NOT BE USED, SEE FOOTING AND FOUNDATION PLAN FOR FOOTING MARKS. 7. THIS SCHEDULE ASSUMES A SOIL BEARING PRESSURE OF 1,500 PSF 8. INFORMATION PROVIDED HERE IS DESIGNED BY NES AND MAY ONLY BE USED BY PERMISSION. 9. THIS SCHEDULE WAS ADOPTED AS PART OF NES STANDARDS IN JULY 2018, FULL CALCULATION PACKAGE ON FILE IN NES MAIN OFFICE. EQ EQ CONCRETE FOOTING SCHEDULE WIDTH 2'-6" 2'-9" 1'-6" LENGTH DEPTH 10" 10" 10" FS1.75 3,675 LBEQ1'-9" 10" FS2.0 4,800 LBEQ2'-0" 10" FS2.25 6,075 LBEQ2'-3" 10" FS3.0 10,800 LB4#4 EQEQ3'-0" 10" 2'-6" 2'-9" 1'-6" 1'-9" 2'-0" 2'-3" 3'-0" 2 #4 2 #4 3#4 3#4 2'-6" 1'-6" 1'-9" 2'-0" 2'-3" 1'-0" 1'-3"EQ EQ EQ EQ 3#4 3#4 4#4 2#4 2#4 3#4 3#4 2'-6" 1'-6" 1'-9" 2'-0" 2'-3" 1'-0" 1'-3" FC1.5 2,000 LB/FTEQ1'-6" 10" FC1.75 2,400 LB/FTEQ1'-9" 10" 1 #4 #4CONT CONT #5 12" O.C.2 2CONT CONT FC1.3 1,800 LB/FTEQ1'-4" 10"#4CONT 2 CONT 1'-2" 1'-3" 1'-0" 1 #5 12" O.C. 1 #4 12" O.C. DIAGRAM DEPTH COLUMN SHALL APPLY FORCE IN CENTER UNLESS OTHERWISE NOTED W I D T HLEN GTH REINFORCING LENGTHWISE REINFORCING CROSSWISE DEPTH WALL (OR COLUMN) SHALL APPLY FORCE IN CENTER UNLESS OTHERWISE NOTED W I D T HLENGTH REINFORCING LENGTHWISE REINFORCING CROSSWISE LC . COMMENTSTOP AND BOTTOM WALL TYPEHORIZONTAL REINFORCINGMARKTHICKNESSVERTICAL 6" THICKNESS 12" 10" 8" #4 BARS AT 18" O.C. E.F. #4 BARS AT 16" O.C. #4 BARS AT 18" O.C. #4 BARS AT 18" O.C. VERTICAL REINFORCING SEE GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS. 2. 1. CONCRETE FOUNDATION WALL NOTES: #4 BARS AT 16" O.C. E.F. #5 BARS AT 15" O.C. #4 BARS AT 12" O.C. #4 BARS AT 16" O.C. HORIZONTAL REINFORCING CONCRETE FOUNDATION WALLS NOT DESIGNATED ON PLANS SHALL BE REINFORCED AS FOLLOWS: CONCRETE WALL SCHEDULE TYPE 'D' VERTICAL TYPE 'C' REINFORCING REINFORCING HORIZONTAL TYPE 'B' VERTICAL REINFORCING HORIZONTAL TYPE 'A' REINFORCING WALL REINFORCING PLACEMENT TYPES: ABBREVIATIONS: E.F. I.F. O.F. EACH FACE INSIDE FACE OUTSIDE FACE IN S I D E FA C E 6" 10" 8" #4 BARS AT 16" O.C. #4 BARS AT 18" O.C. #4 BARS AT 18" O.C.#4 BARS W/IN 12" FROM TOP AND AT 1/3 POINTS UNLESS OTHERWISE NOTED (1) #4 BAR (1) #4 BAR (1) #4 BAR IN S I D E FA C E 1 1/2" 'A' 'A' 'A' 1 1/2" CW-8 CW-6 CW-10 CONCRETE WALLS BAR AT CORNER TO MATCH VERT WALL REINFORCING (2) BARS AT INTER. TO MATCH VERT WALL REINFORCING CORNER BAR(S) CONCRETE WALL, SEE PLAN AND SCHEDULE BEND NORMAL WALL REINFORCING OR PROVIDE BAR OF SAME SIZE AND SPACING WITH LAP AS PER GENERAL STRUCTURAL NOTES, TYPICAL CORNER BARS CONCRETE WALL, SEE PLAN AND SCHEDULE BAR AT INTERSECTION TO MATCH VERT WALL REINFORCING CORNER BAR (2) BARS AT CORNER TO MATCH VERT WALL REINFORCING t 0. 5 t 0. 5 t 0. 2 5 t 0.15t 0. 2 5 t CONTROL JOINT CONSTRUCTION JOINT SLOPE = 1:3 EDGE EACH SIDE OF JOINT WITH 1/8" RADIUSCONCRETE SLAB ON GRADE, SEE PLAN WITHIN FIRST 12 HOURS OF SLAB POUR CONCRETE SLAB ON GRADE, SEE PLAN t 4" MIN. 3/4" CRUSHED GRAVEL COMPACTED TO 95% OF MODIFIED PROCTOR (ASTM-D1557) 4" MIN. 3/4" CRUSHED GRAVEL COMPACTED TO 95% OF MODIFIED PROCTOR (ASTM-D1557) COMPACTED STRUCTURAL FILL OR COMPETENT UNDISTURBED NATIVE SOIL COMPACTED STRUCTURAL FILL OR COMPETENT UNDISTURBED NATIVE SOIL CONTROL OR CONSTRUCTION JOINTS STEEL COLUMN, SEE PLAN AND SCHEDULE CONCRETE BLOCKOUT DEPRESSED CONCRETE SLAB (2) #4 x 4'-0" BARS WHERE CONTROL/ CONSTRUCTION JOINTS DO NOT EXTEND FROM CORNERS OF CONCRETE BLOCKOUTSAT BUILDING COLUMNS (2) #4 x 4'-0" BARS WHERE CONTROL/ CONSTRUCTION JOINTS INTERSECT BUT DO NOT CONTINUE BEYOND INTERSECTION (2) #4 x 4'-0" BARS AT EACH CORNER OF DEPRESSED SLAB WHERE CONTROL/CONSTRUCTION JOINTS DO NOT EXTEND FROM CORNER CONTROL OR CONSTRUCTION JOINT 1 2 3 4 5 1 2 3 4 5 D C B A D C B A 1712 CABALLERO DR. AMMON, IDAHO 83406 (208) 932-2720 WWW.NOESIS.US DRAWN BY DATE DESIGNED BY DATE CHECKED BY DATE AL W A Y S T H I N K SA F E T Y NOESIS ENGINEERING SERVICES, P.C. THIS DOCUMENT WAS ELECTRONICALLY SIGNED. THE DIGITAL CERTIFICATE IS IDENTIFIED ON THE 1ST PAGE OF THE ORIGINAL FILE. THE ORIGINAL DOCUMENT IS LOCATED AT NOESIS ENGINEERING SERVICES, PC HOME OFFICE SERVER UNDER THE JOB NUMBER FOLDER/7.0 ORIGINAL DOCUMENTS. DKB 6/5/2023 9:40:10 AM 6/5/2023 9:40:10 AM 6/5/2023 9:40:10 AM SCHEDULES S-601 CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG, ID 83440 DA R E N W A R D R E L L CO R C O R A N 6 U N I T 22 0 3 1 -RE V 2 JL JL DAREN WARDRELL 2 HOLDDOWN SCHEDULE 1 CONC. FOOTING SCHEDULE 3 CONC. WALL SCHEDULE 4 TYP CORNER WALL REINFORCING 7 TYP SLAB ON GRADE JOINT DETAIL 5 LOCATIONS REQUIRING ADDITIONAL SLAB REINFORCING1 No. Description Date 06/05/2023 MINIMUM NAILING SCHEDULE SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL 16d AT 16"O.C. BRIDGING TO JOIST, TOENAIL EACH END (2) 8d BLOCKING BETWEEN JOIST OR RAFTERS TO TOP PLATE, TOE NAIL (3) 8d RIM JOIST TO TOP PLATE, TOE NAIL 8d AT 6" O.C. COLLAR TIE TO RAFTER, FACE NAIL (3) 10d JACK RAFTER TO HIP, TOE NAIL (3) 10d FACE NAIL (2) 16d ROOF RAFTER TO 2x RIDGE BEAM, TOE NAIL (2) 16d FACE NAIL (2) 16d JOIST TO BAND JOIST, FACE NAIL (3) 16d LEDGER STRIP, FACE NAIL (3) 16d TOP PLATE TO STUD, END NAIL (2) 16d DOUBLE STUDS, FACE NAIL 16d AT 24" O.C. DOUBLED TOP PLATES, FACE NAIL 16d AT 16" O.C. TOP PLATES, LAPS & INTERSECTION, FACE NAIL (2) 16d CONTINUOUS HEADER, TWO PIECES 16d AT 16" O.C. ALONG EACH EDGE CEILING JOISTS TO PLATE, TOE NAIL (3) 8d CONTINUOUS HEADER TO STUD, TOENAIL (4) 8d CEILING JOISTS, LAPS OVER PARTITIONS, FACE NAIL (3) 16d CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL (3) 16d RAFTER TO PLATE, TOENAIL (3) 8d 1" BRACE TO EACH STUD & PLATE, FACE NAIL (2) 8d BUILT-UP CORNER STUDS 16d AT 24" O.C. BUILT-UP GIRDER & BEAMS 20d AT 32" O.C. AT TOP, BOTTOM, AND STAGGERED. (2) 20d AT ENDS AND AT EACH SPLICE. PLYWOOD & PARTICLEBOARD: SUBFLOOR, ROOF & WALL SHEATHING (TO FRAMING)* 1/2" AND LESS 8d 19/32" -3/4"8d OR 10d 7/8" -1"8d 1 1/8" -1 1/4"8d OR 10d COMBINATION SUBFLOOR-UNDERLAYMENT (TO FRAMING)* 3/4" AND LESS 6d 7/8" - 1"8d 1 1/8" -1 1/4"8d OR 10d CONNECTION NAILING *NAILS SPACED AT 6" O.C. AT EDGES, 12" O.C. AT INTERMEDIATE SUPPORTS (EXCEPT WHERE SPANS ARE 48" OR MORE, THEN SPACE AT 6" O.C. AT SUPPORTS). FOR NAILING OF DIAPHRAGMS AND SHEAR WALLS, REFER TO SHEARWALL SCHEDULE. MINIMUM NAILING NOTES: 1. NAILING SCHEDULE IS PER TABLE 2304.10.1 OF THE I.B.C. 2018. 2. NAILING REQUIREMENTS SHOWN HERE DO NOT REPLACE HARDWARE SHOWN ON THE PLANS OR DETAILS. 3. ALL NAILS USED ARE COMMON NAILS. 4. SEE GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS. SHEATHING SCHEDULE AT ROOF AND FLOOR THICKNESS WOOD SHEATHINGLOCATION CONT EDGE NAIL BOUNDARY COMMENTSEDGE BLOCK FIELD NAILOTHER EDGE EDGE NAILNAIL SIZE NO6 IN8d7/16" 24/0ROOF 6 IN 1/8" GAP AT END JOINTS 1/ 1 6 " G A P A T S I D E J O I N T S CENTER EDGES OF PLYWOOD ON JOISTS AND BLOCKS EDGE NAIL, OTHER EDGE FIELD NAILING BOUNDARY NAILEDGE BLOCKING WHERE REQ'D, LAY FLAT (UNO) SHEATHING. STAGGER JOINTS AND ALTERNATE GRAIN DIRECTIONS EDGE NAIL CONTINUOUS EDGE (WHEN BLOCKING IS REQUIRED) NO6 IN10d23/32" OSB (48/24)FLOOR 6 IN LEDGER WALL (WHERE OCCURS), SEE PLAN SHEATHING NOTES: 1. MINIMUM NAIL PENETRATION INTO FTAMING: 8d-1 1/2", 10d- 1 5/8". 2. USE COMMON NAILS (8d DIAMETER = 0.131", 10d DIAMETER = 0.148". 3. SEE GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS. 12 IN 12 IN 6 IN 6 IN SECTION HEADER BEARING SCHEDULE FOR 2x STUD WALL HEADER SPAN MAXIMUMHEADERMARK JAMB COMMENTS KING STUDSBEARING STUDS 2x WALL STUDS, TYP 2x CONT PLATE WOOD HEADER. (3) 2x's WITH 1/2" FILLER TRIM STUD(S) KING STUD(S) 16d NAILS @ 1.5" O.C. (MIN. 4) EACH END OF HEADER WH-1 (3) 2X10 DF #2 OR BETTER ----WH-2 WH-3 ---- (1) 2X6 (2) 2X6 (1) 2X6 (1) 2X6 NOTE: MEMBER SIZES SHOWN ARE MINIMUM DEPTHS AND WIDTHS (3) 2X12 DF #2 OR BETTER (2) 2X10 DF #2 OR BETTER ----(1) 2X6 (1) 2X6 EDGE NAILING, TYP FIELD NAILING, TYP BLOCKING. BLOCK ALL JOINTS WALL STUDS HOLDOWN WHERE OCCURS FLOOR SLAB OR FOUNDATION WALL 1/8" GAP AT END JOINTS SI D E J O I N T S WOOD SHEATHING SHEARWALL SCHEDULE TOPMARK COMMENTSSTUDS WALL FRAMING BOTTOM PLATE ANCHORS STUD & BLOCK AT JOINTS WALL SHEATHING THICKNESS EDGE NAIL FIELD NAIL WOOD SHEATHING SHEARWALL NOTES: 1. PROVIDE 3/16"x2"x0'-2" WASHER PLATES AT BOLTS. 2. WHERE CALLED FOR ON SCHEDULE, USE COMMON NAILS. GALVANIZED NAILS SHALL BE HOT-DIPPED OR TUMBLED. 3. ANCHOR BOLTS SHALL HAVE A 7" MINIMUM EMBEDMENT INTO CONCRETE AND TERMINATE WITH A 3" STANDARD 90° HOOK. 4. WHERE STUDS ARE CUT FOR PLACEMENT OF ANCHOR BOLTS OR OTHER ELEMENTS, AN ADJACENT STUD SHALL BE ADDED. 5. WHERE WOOD SHEATHING IS APPLIED TO BOTH SIDES OF A WALL AND NAIL SPACING IS LESS THAN 6" O.C. ON EITHER SIDE, PANEL JOINTS SHALL BEOFFSET TO FALL ON DIFFERENT FRAMING MEMBERS, OR FRAMING MEMBER SHALL BE 3" OR THICKER AND NAILS ON EITHER SIDE SHALL BE STAGGERED. 6. PRE-DRILLED HOLES ARE REQUIRED AT 20d NAILS. 7. SEE GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS. 8. ALL WOOD SHEAR WALLS GREATER THAN 16' TALL SHALL HAVE ALL PANEL EDGED BLOCKED AND NAILED AT EDGE NAIL SPACING FASTENER TYPEPLATE BOTTOM PLATE SW-1 2x6 AT 16" O.C.(2) 2x6 2x6 5/8"∅A.B. AT 48" O.C.2x 7/16"NAILS 6" O.C.12" O.C. 1/ 1 6 " G A P A T WOOD WALL SHEATHING ALTERNATE DIRECTION OF WOOD GRAINS. AT CONTRATOR'S OPTION, SHEATHING MAY BE INSTALLED VERTICALLY CENTER EDGES OF PLYWOOD ON STUDS AND BLOCKS WOOD SILL (ANCHOR BOLTS AND NAILING NOT SHOWN) JOINT STUD NOTE 8 FASTENER SIZE 8d SW-3 2x6 AT 16" O.C.(2) 2x6 2x6 5/8"∅A.B. AT 48" O.C.2x 7/16"NAILS 3" O.C.12" O.C.NOTE 88d 12"12" 2" M A X 2" M A X DOUBLE 2x IN 6" STUD WALL DOUBLE 2x TRIPLE 2x QUADRUPLE 2x 1/2"∅THRU-BOLT AT 24" O.C. -STAGGERED 16d NAILS AT 12" O.C. EA SIDE -STAGGERED 16d NAILS AT 12" O.C. EA SIDE -STAGGERED 4'-0" MINIMUM LAP TOP PLATE SPLICE SPLICE BOTTOM PL OVER STUD (2) 16d AT 4" O.C. ((24) 16d MIN EA SIDE OF EA SPLICE) TYPICAL WALL STUDS 1 2 3 4 5 1 2 3 4 5 D C B A D C B A 1712 CABALLERO DR. AMMON, IDAHO 83406 (208) 932-2720 WWW.NOESIS.US DRAWN BY DATE DESIGNED BY DATE CHECKED BY DATE AL W A Y S T H I N K SA F E T Y NOESIS ENGINEERING SERVICES, P.C. THIS DOCUMENT WAS ELECTRONICALLY SIGNED. THE DIGITAL CERTIFICATE IS IDENTIFIED ON THE 1ST PAGE OF THE ORIGINAL FILE. THE ORIGINAL DOCUMENT IS LOCATED AT NOESIS ENGINEERING SERVICES, PC HOME OFFICE SERVER UNDER THE JOB NUMBER FOLDER/7.0 ORIGINAL DOCUMENTS. DKB 6/5/2023 9:40:15 AM 6/5/2023 9:40:15 AM 6/5/2023 9:40:15 AM SCHEDULES S-602 CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG, ID 83440 DA R E N W A R D R E L L CO R C O R A N 6 U N I T 22 0 3 1 -RE V 2 JL JL DAREN WARDRELL 1 MINIMUM NAILING SCHEDULE 2 SHEATHING SCHEDULE AT ROOF AND FLOOR 3 WOOD HEADER SCHEDULE 4 WOOD SHEATHING SHEARWALL SCHEDULE 5 WOOD BUILT-UP BEAM DETAILS 6 TOP PLATE SPLICE No. Description Date 06/05/2023 R CO SD DM VS 120V RECEPTACLE LIGHT SWITCH VACANCY SENSOR DIMMER RECESSED LED ICAT FIXTURE SURFACE MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE FAN W/ HUMIDISTAT CONTROL FAN-LIGHT W/ HUMIDISTAT CONTROL SMOKE ALARM 110v w/BATTERY BACKUP C0 ALARM 110v w/BATTERY BACKUP SURFACE MOUNTED LED "SHOP" LIGHT CEILING FAN UP MINI-SPLIT CEILING CASSETTE MINI-SPLIT CEILING CASSETTE MINI-SPLIT CEILING CASSETTE MINI-SPLIT CEILING CASSETTE MINI-SPLIT CEILING CASSETTE MINI-SPLIT CEILING CASSETTEUNDER FLOOR WH UNDER FLOOR WH UNDER FLOOR WH 22X24 UNDER FLOOR ACCESS 22X24 UNDER FLOOR ACCESS DRYER VENT W/DAMPER DRYER VENT W/DAMPER DRYER VENT W/DAMPER R R GFCI GFCI GFCIGFCIGFCI GFCI GFCI GFCI GFCIGFCI GFCI GFCI GFCI GFCI GFCI GFCIGFCI GFCI GFCI SD SD SD SD SD SD SD SD 3 3 EP EP EP BEDROOM BATH LIVING KITCHEN BEDROOM BEDROOM CLOSET CLOSET BATH LIVING LIVING BEDROOM CLOSET CLOSET BEDROOM BATH KITCHEN KITCHEN FIRE RISER (6) 100 AMP METER ELEC MAIN FIRE ALARM PANEL HOUSE PANEL CLOSET ELECTRIC HEATER DN MINI-SPLIT CEILING CASSETTE MINI-SPLIT CEILING CASSETTE MINI-SPLIT CEILING CASSETTE MINI-SPLIT CEILING CASSETTE MINI-SPLIT CEILING CASSETTE MINI-SPLIT CEILING CASSETTE WH WH WH WH WH WH DRYER VENT W/DAMPER DRYER VENT W/DAMPER 3 33 3 3 SD SD SD SD SD SD SD SD GFCI GFCIGFCIGFCI GFCIGFCIGFCI GFCI GFCI GFCI GFCI GFCIGFCIGFCI GFCI GFCI GFCI GFCI GFCI R R R R R EP EP EP CLOSET CLOSET KITCHEN LIVING BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM LIVING LIVING BATH BATH BATH KITCHEN KITCHEN DECK CLOSET FR REVISIONS SHEET: SCALE: DATE: 11 6/7/2023 1ST FLOOR ELECTRICAL PLAN SCALE: 1/4" = 1' ELECTRICAL NOTESELECTRICAL NOTES a.A grounding electrode shall be provided per [CEC Article 250-50]. b.Provide two or more 20-amp small-appliance circuits to serve all countertop, wall and floor receptacles in the kitchen, pantry, breakfast room, dining room, or similar areas. Receptacle outlets shall be installed at each wall, island and peninsular counter space in kitchens and dining rooms per the requirements found in [CEC Article 210.52 (B) and (C)]. Such circuits shall have no other outlets. c.At least one 20-ampere branch circuit shall be dedicated to supply bathroom receptacles. At least one receptacle is required within 3-ft of each basin. [CEC Articles 210.11(C)(3)] [CEC 210.52(D)]   d.Where the 20-ampere circuit supplies a single bathroom, outlets for other equipment within the same bathroom shall be permitted to be supplied in accordance with [CEC Article 210.23(A)(1) and (A)(2)]. e.At least one additional 20-ampere branch circuit shall be dedicated to supply laundry receptacle outlet(s) required by [CEC Articles 210-11(C)(2) & 210-52(F)]. This circuit shall have no other outlets. f.Receptacle outlets shall be installed so that no point along the floor line in any wall space is more than 6-ft measured horizontally from an outlet in that space. Receptacle outlets are required in walls 2-ft or greater. Hallways of 10-ft or more in length shall have at least one receptacle outlet. [CEC Art. 210.52(A) and (H)] g.Tamper-Resistant Receptacles in Dwelling Units. In all areas specified in 210.52, all 125 volt, 15 and 20 ampere receptacles shall be listed as tamper-resistant receptacles. [CEC 406.12] h.Light fixtures that weight more than 6lbs or exceed 16-in in any dimension shall not be supported by the screw shell of a lamp holder. [CEC Art. 410.30(A)] i.Outlet boxes or outlet box systems used as the sole support of a ceiling-suspended (paddle) fan shall be listed and marked by the manufacturer as suitable for this purpose. The required marking shall include the maximum weight to be supported for ceiling fans that weigh more than 35-lbs. [CEC Art. 314.27(D), 422.18] j.An accessible 125-volt, single phase, 15 or 20 amp rated receptacle outlet shall be installed on the same level and within 25-ft of heating and air conditioning equipment. This service receptacle shall not be connected to the load side of the equipment disconnecting means. [CEC Art. 210.63] k.Receptacles within bathtub or shower space are prohibited, even if enclosed. [CEC Art. 406.9(C)] l.Cord-connected lighting fixtures, lighting tracks or ceiling-suspended (paddle) fans within 3-ft of horizontal edge and 8-ft vertical above top of tub/shower dam are prohibited. [CEC Art. 410.10(D)] m.All lighting must be high efficacy per Table 150.0-A of the 2016 Energy Code n.All lighting that qualifies as high efficacy per JA8 must be controlled by a dimmer or vacancy sensor. o.All recessed lights must be air tight, IC rated and certified JA8-2016, or JA8-2016-E for elevated temperature and controlled by a dimmer or vacancy sensor p.At least one light located in a bathroom, laundry room, utility room and garage must be controlled by a vacancy sensor. q.Blank electrical boxes greater than 5’ above the floor must be controlled by a dimmer, vacancy sensor or fan control switch.  The quantity of blank electrical boxes is limited to no more that the number of bedrooms. r.Exhaust fans shall be switched separately from lighting s.All outdoor lighting permanently attached to the building must be high efficacy per Table 150.0- A of the 2016 energy code and controlled by a manual on-off switch, motion control and photo- control. t.Illuminated address sign shall be 5 watts or less. JOB NUMBER CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG ID E-1 DRAWN BY: DAREN WARDELL 19802 VIA REDONDA RD. SONORA CA 95370 2ND FLOOR ELECTRICAL PLAN SCALE: 1/4" = 1' A v ailable fault current calculation need ed to v erify A IC rating for m ain breaker. E lectrical work insid e cloud is abov e and bey ond 2 017 N E C req uirem ents. Please v erify this is d esired . R eceptacles req uired in these locations where they are 2 4 " or wid er as per 2 10.5 2 A wall switch-controlled lighting outlet shall be installed in ev ery habitable room (includ ing liv ing room s) as per 2 10.7 0A 1 R eceptacles req uired in these locations where they are 2 4 " or wid er as per 2 10.5 2 Id aho has ad opted 2 017 N E C , not C E C