Loading...
HomeMy WebLinkAboutMECHANICAL PLANS - 23-00908 - Aveyo Solar - AdditionPLUMBING GENERAL NOTES: 1.PROVIDE ALL LABOR, MATERIAL, AND EQUIPMENT TO CONSTRUCT A COMPLETE AND OPERABLE PLUMBING SYSTEM AS SHOWN. ALL PERMITS AND APPLICABLE FEES SHALL BE INCLUDED. 2.ALL INSTALLATION OF THE PLUMBING SYSTEM SHALL COMPLY WITH ALL JURISDICTION ADOPTED CODES. LOCAL, STATE, UNIFORM, OR INTERNATIONAL CODES IN EFFECT AT THE BEGINNING OF THE PROJECT CONSTRUCTION SHALL GOVERN PROJECT REQUIREMENTS. 3.ALL INSTALLATION SHALL BE COORDINATED WITH ALL OTHER TRADES. CONFLICTS WITH ALL OTHER TRADES SHALL BE RESOLVED BEFORE FABRICATION AND INSTALLATION OF ALL MATERIALS AND EQUIPMENT. 4.CONTRACT DRAWINGS ARE SHOWN AS A GENERAL DESIGN IN ARRANGEMENT AND INTENT. CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING MINOR ADJUSTMENTS AS MAY BE REQUIRED TO MAKE A COMPLETE AND OPERABLE SYSTEM. ALL MAJOR DEVIATIONS IN COMPONENT SIZE AND EQUIPMENT VARIATIONS FROM THE CONTRACT DRAWINGS SHALL HAVE PRIOR APPROVAL BY THE CONSULTING ENGINEER. 5.ALL SYSTEM COMPONENTS MAY NOT BE SHOWN ON THESE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR COMMUNICATION WITH OTHER TRADES AND COORDINATION OF ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS. 6.NOT EVERY OFFSET, BEND OR ELBOW ARE SHOWN ON THE DRAWINGS DUE TO THE DIAGRAMMATIC INTENT AND SCALE OF THE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EQUIPMENT LOCATIONS WITH ALL OTHER DRAWINGS AND TRADES. 7.ALL EQUIPMENT, FIXTURES AND COMPONENTS SHALL BE INSTALLED PER THE MANUFACTURES WRITTEN INSTRUCTIONS AND RECOMMENDATIONS. ALL TRANSITIONS, VALVES AND ANY OTHER REQUIRED DEVICES SHALL BE INSTALLED TO MAKE A COMPLETE SYSTEM. 8.ALL EQUIPMENT AND PIPING SHALL BE BRACED TO MEET SEISMIC REQUIREMENTS PER THE LOCAL IDENTIFIED ZONE. ALL BRACING SHALL BE INSTALLED IN ACCORDANCE WITH THE ADOPTED EDITIONS OF UBC, AND IUPC STANDARDS. 9.ALL DOMESTIC WATER PIPING SHALL BE DISINFECTED AND FLUSHED PER AWWA C651 OR C652 STANDARDS. 10.ALL PIPING SHALL BE INSTALLED FOR PROPER EXPANSION AND MOVEMENT. 11.ALL SANITARY SEWER PIPING SHALL BE ABS, OR PVC 12.ALL DOMESTIC WATER PIPING SHALL BE TYPE L COPPER OR PEX PIPING. 13.HOT WATER(HW) AND HOT WATER RETURN(HWR) PIPING TO BE FULLY INSULATED PER CURRENT IECC TABLE C403.11.3 & SECTION C404.4 REQUIREMENTS. RDO DOMESTIC HOT WATER PIPING DOMESTIC COLD WATER PIPING PLUMBING LEGEND VTR SYMBOL VENT THRU ROOF DESCRIPTION V VENT COTG CLEANOUT TO GRADE WCO WALL CLEANOUT CO CLEANOUT PIPE RISE PIPE DROP BALL TYPE ISOLATION VALVE GAS PIPING ROOF OVERFLOW DRAIN PIPING ROOF DRAIN PIPING VENT LINE PIPING G SOIL OR WASTE PIPING RD DOM. HOT WATER RECIRC PIPING CONNECTION POINT TO EXISTING MECHANICAL LEGEND SYMBOL DUCTWORK DESCRIPTION CONCENTRIC SQUARE TO ROUND TRANSITION MOTORIZED DAMPERM MANUAL VOLUME DAMPER SWITCH THERMOSTATT SUPPLY DIFFUSER RETURN GRILLE EXHAUST GRILLE GAS LINEG HVAC GENERAL NOTES: 1.VERIFY ALL PROJECT SITE DIMENSIONS AND CONDITIONS PRIOR TO COMMENCEMENT OF WORK. 2.ALL APPLICABLE BUILDING CODES SHALL BE FOLLOWED FOR PERFORMANCE OF THIS WORK. 3.INSTALLATION OF ALL DUCTWORK SHALL FOLLOW APPLICABLE SMACNA STANDARDS. 4.FLEX DUCT LENGTH SHALL NOT EXCEED 6 FT. 5.DUCT DIMENSIONS SHOWN ON THE DRAWINGS INDICATE INSIDE FREE AREA. DUCT LINER SHALL BE ADDED TO OVERALL DIMENSION OF THE DUCT. 6.SPECIAL CONDITIONS APPLY TO ALL DUCTWORK AND PIPING PASSING THROUGH FIRE RATED WALLS. SEE APPLICABLE FIRE CODE FOR FIRE STOPPING REQUIREMENTS. 7.ALL REQUIRED MECHANICAL AND ELECTRICAL EQUIPMENT AND DEVICE ACCESSES SHALL BE MAINTAINED TO THE APPLICABLE CODES FOR ALL MECHANICAL ITEMS SHOWN. 8.REFER TO ELECTRICAL DRAWINGS FOR MOUNTING HEIGHTS OF THERMOSTATS. 9.MECHANICAL OPERATION AND MAINTENANCE MANUALS SHALL BE PROVIDED IN A THREE RING BINDER CONTAINING SUBMITTALS, INSTRUCTIONS, AND WARRANTY (3) REQUIRED. 10.ALL MECHANICAL SYSTEMS SHALL BE TESTED, ADJUSTED, AND BALANCED BY A CERTIFIED PROFESSIONAL TESTING AGENCY (NEBB). FIRE DAMPERF COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 M0 . 0 ME C H A N I C A L CO V E R S H E E T Sh e e t : 1 o f 1 8 DN OPEN TO BELOW KEY NOTES: 1.ALL EXISTING HVAC EQUIPMENT AND OR HVAC ROOF PENETRATIONS TO BE COMPLETELY REMOVED. ALL PENETRATIONS SHALL BE SEALED WEATHER TIGHT TO MATCH EXISTING. 2 2 2 2 2 COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 M1 . 2 MA I N L E V E L HV A C D E M O L I T I O N P L A N MAIN LEVEL HVAC DEMO 1/4" = 1'-0"NORTH 0 4'8'16' Sh e e t : 2 o f 1 8 KEY NOTES: 1.EXISTING ROOFTOP UNIT AND ASSOCIATED CURB TO BE REMOVED. ROOF SHALL BE PATCHED WEATHER TIGHT TO MATCH EXISTING. 2.ALL EXISTING HVAC EQUIPMENT AND OR HVAC ROOF PENETRATIONS TO BE COMPLETELY REMOVED. ALL PENETRATIONS SHALL BE SEALED WEATHER TIGHT TO MATCH EXISTING. 1 1 1 2 2 2 2 2 COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 M1 . 4 RO O F L E V E L HV A C D E M O L I T I O N P L A N ROOF LEVEL HVAC DEMO 1/4" = 1'-0"NORTH 0 4'8'16' Sh e e t : 3 o f 1 8 UP UP UP UP KEY NOTES: 1.ROUTE 6"Ø EXHAUST DUCT UP TO ROOF CAP. SEE HVAC ROOF PLAN, SHEET M2.0 FOR CONTINUATION. 2.CONNECT 12"Ø OSA DUCT TO RA ON FURNACE WITH 12V MOTORIZED AND VOLUME DAMPER. BALANCE TO CFM INDICATED IN FURNACE SCHEDULE. 3.INSTALL 20X14 INTAKE LOUVER EQUAL TO RUSKIN ELF375DX WITH A MINIMUM FREE AREA OF 0.57 SQUARE FEET. PROVIDE WITH BIRD SCREEN AND FLANGE AS APPROPRIATE FOR EXTERIOR CONSTRUCTION. COORDINATE COLOR WITH ARCHITECT OF RECORD. STORAGE STORAGE STORAGE MECH. FOYER STORAGE MEN WOMEN FOYER SHWR SHWR 0-2 FC 0-1 FC T (FC 0-2) T(FC 0-1) 0-3 FC 1 EWH 1 EWH T (FC 0-3) 2 EWH 2 EWH ROUTE 12"Ø SA DUCT BELOW STAIR LANDING 12" Ø S A 16 X 1 0 S A 170 SG-1 170 SG-1 170 SG-1 T(F-1) 175 SG-1 175 SG-1 175 SG-1 170 SG-1 115 SG-1 12X8 SA 50 CD-1 150 SG-1 150 SG-1 12 " Ø S A 10 " Ø S A 20 X 1 2 S A 26X12 RA(LINED) M 3 2 PROVIDE 20X36 OPENING ON TOP OF DUCTWORK. COVER WITH 1/2" OPEN WIRE MESH. 26X12 RA(LINED) 1 F 100 EG-2 100 EG-2 50 EG-1 (TYP. OF 2) 10"Ø EA 1 EF 10"Ø EA WALL CAP 160 SG-1 (TYP. OF 4) 20X10 RA(LINED) PROVIDE 14X36 OPENING ON TOP OF DUCTWORK. COVER WITH 1/2" OPEN WIRE MESH. COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 M2 . 1 BA S E M E N T L E V E L HV A C P L A N BASEMENT HVAC PLAN 1/4" = 1'-0"NORTH 0 4'8'16' Sh e e t : 4 o f 1 8 KEY NOTES: 1.ROUTE 6"Ø EXHAUST DUCT UP TO ROOF CAP. SEE HVAC ROOF PLAN, SHEET M2.0 FOR CONTINUATION. 2.UNIT SIZED SUPPLY AND RETURN DUCTS DOWN FROM RTU. SEE HVAC ROOF PLAN, SHEET M3.1 FOR CONTINUATION. 3.PROVIDE DUCTED TRANSFER OVER CENTER OF DOOR. 4.PROVIDE 16X44 OPENING ON TOP OF DUCTWORK. COVER WITH 1/2" OPEN WIRE MESH. 5.SUPPLY GRILLE TO BE MOUNTED AT 30° BELOW THE HORIZONTAL CENTERLINE. UP UP DN D N DN DW F OPEN TO BELOW OFFICE OFFICE OFFICE OFFICE MEN'S WOMEN'S 0-1 HP 1 CU 2 EWH 2 EWH 2 EWH 1 EWH 230 SG-1 350 CD-8 20 " Ø S A 18"Ø SA 14 " Ø S A 360 CD-8 360 CD-8 14"Ø SA 2 20"Ø RA 4 5230 SG-15230 SG-15230 SG-15 T(RTU-4) RG-4 (TYP. OF 2) RG-4 (TYP. OF 2) 3 3 20 " Ø S A 20"Ø RA 4 230 SG-15 230 SG-15 120 CD-2 12"Ø SA 18"Ø SA 230 SG-15 230 SG-15 230 SG-15 230 SG-1 5 240 CD-7 130 CD-6 14"Ø SA T (RTU-3) 2 RG-4 (TYP. OF 2) 3 RG-4 (TYP. OF 2) 3 120 CD-2 2 EF 3 EF 8"Ø EA WALL CAP 8"Ø EA WALL CAP 4 EF 6"Ø EA WALL CAP 1-1 HP 1-2 FC 1-1 FC T(FC 1-3) T (FC 1-2) T (FC 1-1) SA AND RA DUCTS FROM ROOF LEVEL. SEE M2.3 FOR CONTINUATION. T(RTU-2) 18X16 RA 18X16 SA 320 CD-4 320 CD-4 200 CD-4 250 CD-4 200 CD-4 250 CD-4 200 CD-4 250 CD-4 16X14 SA RG-3 (TYP. OF 3) 1-3 FC COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 M2 . 2 MA I N L E V E L HV A C P L A N MAIN LEVEL HVAC PLAN 1/4" = 1'-0"NORTH 0 4'8'16' Sh e e t : 5 o f 1 8 KEY NOTES: 1.UNIT SIZED SUPPLY AND RETURN DUCTS DOWN FROM RTU. SEE HVAC ROOF PLAN, SHEET M3.1 FOR CONTINUATION. 2.SUPPLY AND RETURN DUCTS DOWN FROM RTU. SEE HVAC ROOF PLAN, SHEET M3.1 FOR CONTINUATION. DUCTWORK SHALL TRANSITION TO SIZE NOTED AND ROUTE DOWN TO FIRST FLOOR CEILING SPACE. 3.SMOKE DETECTOR TO BE PROVIDED WITH RTU TO SHUT DOWN UNIT UPON DETECTION OF SMOKE. DN UP DO W N UP 10X8 SA 110 CD-3 185 CD-3 175 CD-3 190 CD-3 190 CD-3 175 CD-3 175 CD-3 440 CD-5 110 CD-3 110 CD-3 110 CD-3 130 CD-3 300 CD-4 20X16 SA 18X14 SA 22X16 RA 1 18X12 RA 16X10 SA 16X10 RA RG-1 RG-1 RG-1 RG-1 RG-3 RG-2 RG-1 RG-1 RG-1 RG-1 RG-1 RG-3 T(RTU-1) SD3 2 18X16 SA 18X16 RA COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 M2 . 3 Sh e e t : 6 o f 1 8 SE C O N D L E V E L HV A C P L A N SECOND LEVEL HVAC PLAN 1/4" = 1'-0"NORTH 0 4'8'16' KEY NOTES: 1.NEW RTU TO BE INSTALLED ON EXISTING ROOF THIS AREA. ROOF SHALL BE PATCHED WEATHER TIGHT TO MATCH EXISTING. 4 RTU3 RTU 1 RTU 2 RTU 1 1 COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 M3 . 1 Sh e e t : 7 o f 1 8 RO O F L E V E L HV A C P L A N ROOF LEVEL HVAC PLAN 1/4" = 1'-0"NORTH 0 4'8'16' DUCT CONSTRUCTION & HANGER DETAIL DIMENSION OF LONGEST SIDE, INCHES SHEET METAL GAGE (ALL FOUR SIDES) MINIMUM REINFORCING ANGLE SIZE AND MAX LONGITUDINAL SPACING BETWEEN TRANSVERSE JOINTS AND/OR INTERMEDIATE REINFORCING TRANSVERSE REINFORCING, (I) AT JOINTS UP THRU 12 26 NONE REQ'D 26 26 13 - 18 24 NONE REQ'D 24 24 19 - 30 24 1"x1"x1/8" @ 60"-24 DRIVE SLIP HEMMED S SLIP RECOM- MANDED GAGE RECOM- MANDED GAGE (1) TRANSVERSE REINFORCING SIZE IS DETERMINED BY DIMENSION OF SIDE TO WHICH ANGLE IS APPLIED. METAL FASTENERS - OMARK INSULPING DURO DYNE FASTENERS OR GRIPNAILS. GRIP NAILS SHALL BE INSTALLED BY GRIPNAIL HAMMER GUN OR BY AUTOMATIC FASTENER EQUIPMENT. SELF-TAPPING CADMIUM PLATED HEX HEAD SHEET METAL SCREW HANG DUCTS UP TO 30" WIDTH WITH 1" X 18 GAGE STRAPS @ 10'-0" MAX SPACING STRAPS TO BE TIGHT AGAINST DUCTWORK NO POP RIVETS ALLOWED SHEET METAL DUCT PROVIDE SHEET METAL NOSING OR SLEEVE OVER ANY EXPOSED LINER WHICH FACES THE OPPOSITE DIRECTION AS THE AIRFLOW TOP & BOTTOM SECTION OF LINER SHALL OVERLAP THE SIDES SPACING PER SMACNA (TYP.) DUCT LINER NO MORE THAN 2" FROM EDGE OF LINER ALL ENDS OF LINER TO BE COATED W/ ADHESIVE AND SHALL BE BUTTED FIRMLY TOGETHER NO SCALE DUCT SUPPORT 1" ACOUSTICAL LINER ON INTERIOR OF DUCT HAND DAMPER CEILING DIFFUSER DETAIL W/FLEXIBLE DUCT NO SCALE ROUND FLEXIBLE SUPPLY DUCT TO CEILING DIFFUSER 8'-0" MAX. LENGTH GLUE FLEX DUCT TO ADAPTER & CLAMP DOWN WITH STRAP ROUND TO SQUARE TRANSITION LAY-IN DIFFUSER LAY-IN CEILING ATTACH TO RIGID DUCT WITH DRAW BAND DUCT SUPPORT GLUE FLEX DUCT TO FITTING, CLAMP DOWN WITH STRAP AND SCREW SOLID WITH RIGID FILLING BLADE DAMPER ROUND SOLID DUCT HANDLE RIGID SPIN IN FITTING WING NUT RECTANGULAR SUPPLY DUCT EXTERNAL DUCT INSULATION ON ALL ROUND RIGID DUCT- WORK AND FITTINGS VOLUME DAMPER CUT OPENING ACCURATELY FOR SPIN IN (FLARED) FITTING. VOLUME DAMPER. PROVIDE CONCEALED CEILING DAMPER REGULATOR BRANCH DUCT TAKE-OFF DETAIL NO SCALE ALL JOINTS SHALL HAVE A 2" FACING OVERLAYED WITH CIRCUMFERENTIAL JOINTS SEALED WITH 3" WIDE VAPOR BARRIER PRESSURE SENSITIVE FOIL OR VINYL TAPE COMPATIBLE WITH THE FACING. DUCT WRAP 2" THICK, 1.0 lbs. DENSITY DUCT WRAP 2" THICK, 1.0 lbs. DENSITY ROUND DUCT RECTANGULAR DUCT STAPLE LONGITUDINAL JOINTS WITH OUTWARD CLINCHING STAPLES APPROX. 6" ON CENTER AND THEN TAPE THE JOINT WITH 3" WIDE VAPOR BARRIER TAPE. ADHERE INSULATION TO DUCT WITH BONDING ADHESIVE (BENJAMIN FOSTER 85-15 OR I-C-201). FOLDED CORNER DUCT INSULATION DETAIL NO SCALE NOTE: PROVIDE AND INSTALL DURO DYNE SPEC-SEAL/QUAD SEAL DAMPER WING NUT ARM CONTINUOUS ROD ROUND DAMPER DETAIL NO SCALE HANGER STRAPS Ø50" MAX. HANGER STRAP 3 8" BOLT SELF TAPPING CADIUM PLATED HEX HEAD SHEET METAL SCREW. STRAPS TO BE TIGHT AGAINST DUCT ROUND DUCT & STRAP HANGER DETAIL NO SCALE DRAIN ON ROOF 4" M I N . NO LESS THAN 2 TIMES THE PIPE DIAMETER DEEP SEAL P-TRAP DRAIN CONNECTION OPEN TO ATMOSPHERE DRAIN PIPING TO BE THE SAME SIZE AS THE DRAIN PAN CONNECTION SIZE ROOFTOP UNIT UNIT BASE RAIL 2 X 4 FACTORY WOOD NAILER UNIT HOLD DOWN CLIP (BY MECH, CONTRACTOR) COUNTER FLASHING (BY MECH. CONTRACTOR) CANT STRIP (BY MECH. CONTRACTOR) ROOFING MATERIAL (SEE ARCH DRAWINGS) ROOF INSULATION (VERIFY LOCATION W/ARCH. PLANS) ROOF DECK (SEE ARCH DRAWINGS) RIGID INSULATION (BY MECH. CONTRACTOR) SEE SCHEDULE FOR CONN. TYPE & NO. REQUIRED. ROOF STRUCTURE (SEE STRUCTURAL PLANS ROOF TOP UNIT DUCT FLANGE CONNECTION AT ROOF TOP CURB FLEXIBLE CONN. TO ROOF TOP CURB TRANSITION TO UNIT OPENING FACTORY CURB W/MOUNTING FRAME 1 1/2" RIGID INSULATION FOR SOUND PROOFING (BY MECH. CONTRACTOR) BLOCKING BETWEEN ROOF STRUCTUERE: WOOD - 4X4 BLOCKING W/4X4 HANGER ON EACH END. METAL - 4X4X1/4 ANGLE BLOCKING WELDED TO JOIST TOP CHORDS CONCRETE - NO BLOCKING REQUIRED. SEE DETAIL A DIM. BASED ON ROOFTOP MANUFACTURE FASTEN TO UNIT CURB W/ (2) #12 SCREWS FASTEN TO UNIT BASE RAIL W/ (2) #12 SCREWS UNIT HOLD DOWN CLIP. 14 GAUGE GALV. STEEL ALL DIMENSIONS ARE I.D. (TYP OF 4) ROOFTOP UNIT MOUNTING DETAIL NO SCALE CONDENSATE DRAIN (ROOFTOP UNIT)NO SCALE COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 M4 . 1 HV A C D E T A I L S Sh e e t : 8 o f 1 8 ROOFTOP UNIT SCHEDULE MANUFACTURER & MODEL NUMBER NOTES NATURAL GAS/ELECTRIC LENNOX KGB072H4B DESCRIPTIONMARK EER/SEERO.A. CFM TOTAL COOLINGOUTPUTMOCP HEATING(MBH) INPUTMCAVOLTAGEHPESPCFM NOM. TONS SUPPLY FAN 6 2,400 0.5 1 208/3 32 50 81/108 65/86 72,200 310 12/-- ELECTRICAL 1 RTU ECONOMIZER, CONVENIENCE OUTLET, HAIL GUARDS, SMOKE DETECTOR, PROGRAMMABLE THERMOSTAT NATURAL GAS/ELECTRIC2 RTU FURNACE SCHEDULE MANUFACTURER & MODEL NUMBER NOTES NATURAL GAS/ELECTRIC LENNOX EL196UH DESCRIPTIONMARK AFUEO.A. CFM HEATING OUTPUTMOCP HEATING INPUTFLAVOLTAGEHPESPCFM NOM. TONS SUPPLY FAN 400 96%PROVIDE WITH MATCHING COIL F 1 ELECTRICAL CONDENSING UNIT SCHEDULE MANUFACTURER & MODEL NUMBER NOTES DIRECT EXPANSION DESCRIPTIONMARK TOTALSENSIBLE NOM. TONS CU 1 COOLING (MBTU/H) MCAVOLTAGE ELECTRICAL MOCP MIN. SEER PROVIDE WITH HOUSEKEEPING PADLENNOX 13ACXN060 5 48,000 53,000 13208/230/1 34.6 60 DIRECT EXPANSION DUCTLESS SPLIT SYSTEM SCHEDULE MANUFACTURER & MODEL NUMBER NOTES LOW AMBIENT HEAT PUMP LENNOX MLB030S4M-1P DESCRIPTIONMARK HEATINGCOOLING 28,000 BTU 28,000 BTU 23.0/10.6 HAIL GUARDS, DEFROST CONTROL, CRANKCASE HEATERHP 0-1 MCAVOLTAGE 208/230/1 25 ELECTRICAL MOCP 40 SEER/HSPF CAPACITY 3/4 TON WALL MOUNT LENNOX MWMC009S4-1P 9,000 BTU 8,800 BTU --FC 0-1 208/230/1 0.25 RLA 20W OUTPUT FC 0-2 WIRED PROGRAMMABLE CONTROLLER, CONDENSATE PUMP, 176/230/335 CFM 3/4 TON WALL MOUNT LENNOX MWMC009S4-1P 9,000 BTU 8,800 BTU --208/230/1 0.25 RLA 20W OUTPUT WIRED PROGRAMMABLE CONTROLLER, CONDENSATE PUMP, 176/230/335 CFM 5 1980 0.50 1 120/1 10.9 15 110 107 FC 0-3 1 TON WALL MOUNT LENNOX MWMC012S4-1P 11,000 BTU 11,700 BTU --208/230/1 0.25 RLA 20W OUTPUT WIRED PROGRAMMABLE CONTROLLER, CONDENSATE PUMP, 176/230/335 CFM LENNOX KGB060S4E 5 1,990 0.5 1 208/1 41 60 81/108 66/87 64,000 470 11/14 ECONOMIZER, CONVENIENCE OUTLET, HAIL GUARDS, PROGRAMMABLE THERMOSTAT NATURAL GAS/ELECTRIC3 RTU LENNOX KGB060S4E 5 1,990 0.5 1 208/1 41 60 81/108 66/87 64,000 310 11/14 ECONOMIZER, CONVENIENCE OUTLET, HAIL GUARDS, PROGRAMMABLE THERMOSTAT NATURAL GAS/ELECTRIC4 RTU LENNOX KGB060S4E 5 1,990 0.5 1 208/1 41 60 81/108 66/87 64,000 240 11/14 ECONOMIZER, CONVENIENCE OUTLET, HAIL GUARDS, PROGRAMMABLE THERMOSTAT LOW AMBIENT HEAT PUMP LENNOX MLB030S4M-1P 28,000 BTU 28,000 BTU 23.0/10.6 HAIL GUARDS, DEFROST CONTROL, CRANKCASE HEATERHP 1-1 208/230/1 25 40 3/4 TON WALL MOUNT LENNOX MWMC009S4-1P 9,000 BTU 8,800 BTU --FC 1-1 208/230/1 0.25 RLA 20W OUTPUT FC 1-2 WIRED PROGRAMMABLE CONTROLLER, CONDENSATE PUMP, 176/230/335 CFM 3/4 TON WALL MOUNT LENNOX MWMC009S4-1P 9,000 BTU 8,800 BTU --208/230/1 0.25 RLA 20W OUTPUT WIRED PROGRAMMABLE CONTROLLER, CONDENSATE PUMP, 176/230/335 CFM FC 1-3 1 TON WALL MOUNT LENNOX MWMC012S4-1P 11,000 BTU 11,700 BTU --208/230/1 0.25 RLA 20W OUTPUT WIRED PROGRAMMABLE CONTROLLER, CONDENSATE PUMP, 176/230/335 CFM COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 M5 . 1 Sh e e t : 9 o f 1 8 HV A C S C H E D U L E S ELECTRIC WALL HEATER SCHEDULE MANUFACTURER & MODEL NUMBER QMARK GFR1500F MARK HEATING EWH 1 WATTS 1500 AMPVOLTAGE 120/1/60 12.5 ELECTRICAL NOTES INTEGRAL THERMOSTAT, SURFACE MOUNT EXHAUST FAN SCHEDULE TYPE CFM ESP HP POWER R.P.M.CONTROL REMARKS EF 3 EF 1 EF 2 COOK GN-622, BACKDRAFT DAMPER, BIRD SCREEN, VIBRATION ISOLATORS, SPEED CONTROLLER 1.42 AMPS3000.20 1021INLINE115/1/60 TIMECLOCK, OCCUPIED HOURS COOK GC-622, BACKDRAFT DAMPER, WALL CAP, BIRD SCREEN, VIBRATION ISOLATORS 1.42 AMPS2100.10 718CEILING115/1/60 LIGHT SWITCH INTERLOCK MARK EWH 2 QMARK AWH3150F 1500 120/1/60 12.5 INTEGRAL THERMOSTAT, SEMI RECESSED MOUNT DIFFUSER, GRILLE, & REGISTER SCHEDULE SYMBOL DESCRIPTION NOTESPATTERNSTYLEFACE SIZE MATERIALDUCT SIZE CD-2 CD-1 KRUEGER SHR, FRAME 22 CD-3 CEILING DIFFUSER 4-WAY18X18STEEL8" Ø EG-1 CEILING EXHAUST FIXED 35° BLADES, 1/2" SPACING KRUEGER S85, FRAME 22STEEL CEILING DIFFUSER 4-WAY SURFACE MOUNT9X9STEEL6" Ø 12" Ø RG-1 RG-4 CEILING RETURN FIXED14X14 35° BLADES, 1/2" SPACINGSTEEL CEILING DIFFUSER 4-WAY SURFACE MOUNT9X9STEEL8" Ø RG-2 CEILING RETURN FIXED14X14 35° BLADES, 1/2" SPACING KRUEGER S85, FRAME 22STEEL8" Ø RG-3 CEILING RETURN FIXED14X14 35° BLADES, 1/2" SPACING KRUEGER S85, FRAME 22STEEL10" Ø 12X12 6"Ø SG-1 SUPPLY GRILLE ADJUSTABLE 3/4" SPACING KRUEGER 5880H, FRAME 22ALUMINUM12X612X6 CD-4 CEILING DIFFUSER 4-WAY18X18STEEL10" Ø KRUEGER S85, FRAME 22 EG-2 CEILING EXHAUST FIXED 35° BLADES, 1/2" SPACING KRUEGER S85, FRAME 22STEEL12X128"Ø CD-6 ROUND DIFFUSER ADJUSTABLE 360° DISCHARGE KRUEGER RA218"Ø STEEL8" Ø CD-7 ROUND DIFFUSER ADJUSTABLE 360° DISCHARGE KRUEGER RA222"Ø STEEL10" Ø CD-8 ROUND DIFFUSER ADJUSTABLE 360° DISCHARGE KRUEGER RA227"Ø STEEL12" Ø 24X12TRANSFER GRILLE FIXED24X12 35° BLADES, 1/2" SPACINGSTEEL KRUEGER S85, FRAME 22 COOK GC-622, BACKDRAFT DAMPER, WALL CAP, BIRD SCREEN, VIBRATION ISOLATORS 1.42 AMPS2100.10 718CEILING115/1/60 LIGHT SWITCH INTERLOCK EF 4 COOK GC-128, BACKDRAFT DAMPER, WALL CAP, BIRD SCREEN, VIBRATION ISOLATORS 0.25 AMPS500.10 555CEILING115/1/60 WALL SWITCH CD-5 CEILING DIFFUSER 4-WAY18X18STEEL12" Ø KRUEGER SHR, FRAME 22 KRUEGER SHR, FRAME 22 KRUEGER SHR, FRAME 22 KRUEGER SHR, FRAME 22 SURFACE MOUNT, OBD SURFACE MOUNT, OBD SURFACE MOUNT, OBD M5 . 2 Sh e e t : 9 o f 1 8 HV A C S C H E D U L E S COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 UP FLANGE AS APPROPRIATE FOR EXTERIOR CONSTRUCTION. COORDINATE COLOR WITH ARCHITECT OF RECORD. KEY NOTES: 1.EXISTING FIXTURE AND/OR ABANDONED UTILITY LINES (CW, HW, WASTE, VENT) THIS AREA TO BE COMPLETELY REMOVED WHERE ACCESSIBLE. ABANDONED LINES SHALL BE CAPPED. 2.EXISTING INSTANTANEOUS WATER HEATERS TO BE REMOVED AND RELOCATED. ASSOCIATED CONCENTRIC VENT TO REMAIN FOR RE-CONNECTION DURING NEW WORK PHASE. 3.REMOVE ALL EXISTING CW LINES BACK TO EXISTING 2" MAIN SHUTOFF VALVE. 2" CW(E) 23 1 1 1 1 1 1 1 1 1 1 1 1 1 11 1 1 EXISTING 1/2" G TO GAS METER. SEE SHEET P1.2 FOR CONTINUATION. EXISTING VENT LINE FROM BASEMENT LEVEL UP THROUGH ROOF TO BE COMPLETELY REMOVED. ALL ABANDONED PENETRATIONS SHALL BE PATCHED TO MATCH EXISTING. COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 P1 . 1 Sh e e t : 10 o f 1 8 BA S E M E N T L E V E L PL U M B I N G D E M O L I T I O N PL A N BASEMENT PLUMBING DEMO 1/4" = 1'-0"NORTH 0 4'8'16' DN OPEN TO BELOW KEY NOTES: 1.EXISTING AND/OR ABANDONED UTILITY LINES (CW, HW, WASTE, VENT) THIS AREA TO BE COMPLETELY REMOVED WHERE ACCESSIBLE. ABANDONED LINES SHALL BE CAPPED. SEE P1.1 FOR CONTINUATION SEE P1.4 FOR CONTINUATION 1 1 1 1 G G 3/4" G(E) 1/2" G(E)EXISTING GAS METER TO BE REMOVED IF NECESSARY FOR NEW GAS LOAD. SEE SHEET P3.2 FOR NEW FLOW REQUIREMENTS. COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 P1 . 2 Sh e e t : 11 o f 1 8 MA I N L E V E L PL U M B I N G D E M O L I T I O N PL A N MAIN LEVEL PLUMBING DEMO 1/4" = 1'-0"NORTH 0 4'8'16' KEY NOTES: 1.EXISTING RTU AND ASSOCIATED GAS PIPING TO BE REMOVED AS SHOWN. SEE P1.2 FOR CONTINUATION 3/4" G(E) 1 1 1 COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 P1 . 4 Sh e e t : 12 o f 1 8 RO O F L E V E L PL U M B I N G D E M O L I T I O N PL A N ROOF LEVEL PLUMBING DEMO 1/4" = 1'-0"NORTH 0 4'8'16' KEY NOTES: 1.NEW 3" SANITARY SEWER LINE TO BE CONNECTED TO EXISTING SANITARY SEWER LINE THIS AREA. FIELD COORDINATE EXACT LOCATION AND REQUIREMENTS. 2.ROUTE 2" VENT LINE UP IN WALL ABOVE AND THROUGH ROOF. SEE SHEET P2.2 FOR CONTINUATION. 3.EXISTING UTILITY SINK TO BE RE-USED AND RECONNECTED ALONG EXTERIOR WALL THIS AREA. CONFIRM EXACT LOCATION WITH EXISTING SEWER PIPE LOCATED IN WALL. 4.ROUTE 3" SANITARY SEWER LINE FROM ABOVE DOWN STAIRWELL WALL AND CONNECT TO EXISTING 3" OR LARGER SANITARY SEWER LINE BELOW SLAB. FIELD VERIFY EXACT LOCATION AND TIE-IN REQUIREMENTS. UP UP UP UP STORAGE STORAGE STORAGE MECH. FOYER STORAGE MEN WOMEN FOYER SHWR SHWR WC-1 UR-1 SHR-1 SHR-1 LAV-1 LAV-1 2" WCO 3" W 3" WWC-1 1 1 1/2" V THESE SIX FIXTURES TO BE INSTALLED AS A CIRCUIT VENT SYSTEM PER SECTION 911.0 OF THE 2017 IDAHO STATE PLUMBING CODE. COORDINATE REQUIREMENTS WITH AHJ. 2" V 2" V 2 3 4 4 COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 P2 . 1 Sh e e t : 13 o f 1 8 BA S E M E N T L E V E L W & V PL U M B I N G P L A N BASEMENT PLUMBING PLAN 1/4" = 1'-0"NORTH 0 4'8'16' KEY NOTES: 1.ROUTE 3" SANITARY SEWER LINE DOWN STAIRWELL WALL AND CONNECT TO EXISTING 3" OR LARGER SANITARY SEWER LINE BELOW SLAB. FIELD VERIFY EXACT LOCATION AND TIE-IN REQUIREMENTS. 2.ROUTE 3" VENT LINE UP THROUGH ROOF. PENETRATION SHALL BE SEALED WEATHER TIGHT TO MATCH EXISTING. UP UP DN D N DN DW F OPEN TO BELOW OFFICE OFFICE OFFICE OFFICE MEN'S WOMEN'S ROUTE 2" VENT LINE FROM BASEMENT LEVEL AND UP THROUGH ROOF. PENETRATION SHALL BE SEALED WEATHER TIGHT TO MATCH EXISTING. WC-1 WC-1 WC-1 UR-1 LAV-1WC-1LAV-1 S-1 THESE SIX FIXTURES TO BE INSTALLED AS A CIRCUIT VENT SYSTEM PER SECTION 911.0 OF THE 2017 IDAHO STATE PLUMBING CODE. COORDINATE REQUIREMENTS WITH AHJ. 1 2 ROUTE 2" RELIEF VENT UP IN WALL. 2" V 3" W 2 3" W2" V 1 2" WCO 2" WCO THESE FIVE FIXTURES TO BE INSTALLED AS A CIRCUIT VENT SYSTEM PER SECTION 911.0 OF THE 2017 IDAHO STATE PLUMBING CODE. COORDINATE REQUIREMENTS WITH AHJ. COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 P2 . 2 Sh e e t : 14 o f 1 8 MA I N L E V E L W & V PL U M B I N G P L A N MAIN LEVEL PLUMBING PLAN 1/4" = 1'-0"NORTH 0 4'8'16' UP UP UP UP ROUTE CW, HW, AND HWR UP TO MAIN LEVEL IN WALL ABOVE. SEE SHEET P3.2 FOR CONTINUATION. KEY NOTES: 1.NEW BACKFLOW DEVICE TO BE INSTALLED PER DETAIL ON P5.1 AND LOCAL JURISDICTION. 2.NEW LOCATION FOR EXISTING WATER HEATERS. RE-CONNECT FLUE AND INTAKE PIPING. CONNECT SIZE NOTED GAS AND WATER LINES PER MANUFACTURER'S RECOMMENDATIONS. WATER HEATER TO BE CONNECTED PER INTERNAL CIRCULATION PUMP REQUIREMENTS. CONCENTRIC VENT PENETRATION AT EXTERIOR WALL SHALL BE RE-SEALED WEATHER TIGHT TO MATCH EXISTING. 3.SEE DETAILS ON P5.1 FOR CONNECTION REQUIREMENTS. PROVIDE 2 PSI - 7" WC PRESSURE REGULATOR FOR NG CONNECTION. 4.EXISTING UTILITY SINK TO BE RE-USED AND RECONNECTED ALONG EXTERIOR WALL THIS AREA. CONFIRM EXACT LOCATION AND ROUTING OF WATER PIPING. 2" CW(E) EXISTING 1/2" G TO GAS METER. SEE SHEET P3.2 FOR CONTINUATION. STORAGE STORAGE STORAGE MECH. FOYER STORAGE MEN WOMEN FOYER SHWR SHWR UR-1 LAV-1 LAV-1 WC-1WC-1 SHR-1 BALANCING VALVE 1 1/4" CW 1" HW 3/4" HWR 1 1/4" CW 1" HW 3/4" HWR 1" CW 1" CW 3/4" HW 1 1/2" CW 1 1/4" HW 3/4" HWR 1 2 4 1 1/4" CW 1 1/4" HW 1 F G G 3 1/2" G 1/2" G 1/2" G COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 P3 . 1 Sh e e t : 15 o f 1 8 BA S E M E N T L E V E L W & G PL U M B I N G P L A N BASEMENT PLUMBING PLAN 1/4" = 1'-0"NORTH 0 4'8'16' UP UP DN D N DN DW F OPEN TO BELOW OFFICE OFFICE OFFICE OFFICE MEN'S WOMEN'S BALANCING VALVE 1 1/4" CW, 1" HW, AND 3/4" HWR UP FROM BASEMENT LEVEL. SEE SHEET P3.1 FOR CONTINUATION. 1" CW 1" HW 3/4" CW 3/4" HW 3/4" HW 1 1/4" CW 1" CW 3/4" HW 3/4" CW 3/4" HWR 1" CW WC-1 WC-1 UR-1 LAV-1 WC-1 LAV-1 S-1 WB-1 HB-1 ROUTE WATER LINE DOWN IN WALL AND THROUGH WALL STUDS TO WB-1 SEE P3.1 FOR CONTINUATION SEE P4.1 FOR CONTINUATION G G 3/4" G(E) 1/2" G(E) EXISTING GAS METER TO BE REPLACED AS NECESSARY FOR NEW GAS LOAD OF 942 MBH AT A DELIVERY PRESSURE OF 2 PSI. (TYP. OF 3) COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 P3 . 2 Sh e e t : 16 o f 1 8 MA I N L E V E L W & G PL U M B I N G P L A N MAIN LEVEL PLUMBING PLAN 1/4" = 1'-0"NORTH 0 4'8'16' FLANGE AS APPROPRIATE FOR EXTERIOR CONSTRUCTION. COORDINATE COLOR WITH ARCHITECT OF RECORD. KEY NOTES: 1.SEE DETAILS ON P5.1 FOR CONNECTION REQUIREMENTS. PROVIDE 2 PSI - 7" WC PRESSURE REGULATOR FOR NG CONNECTION. SEE P3.2 FOR CONTINUATION 3/4" G(E) 4 RTU 3 RTU 1 RTU 2 RTU 1 1 1 1 G G G G G G G 1/2" G 1/2" G 1/2" G 1/2" G COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 P4 . 1 Sh e e t : 17 o f 1 8 RO O F L E V E L PL U M B I N G P L A N ROOF LEVEL PLUMBING PLAN 1/4" = 1'-0"NORTH 0 4'8'16' TURNBUCKLE THRU-BOLT WOOD JOIST ANGLE EYE- BOLTS I-BEAM CLAMPS U-BOLTS ADJUSTABLE PIPE STAND U-BOLTS ANGLE TURNBUCKLE INSERTS WELDED STEEL WALL BRACKET STEEL OFFSET WALL BRACKET U-BOLTS CINCH ANCHORS (TYP.)U-BOLTS TYPICAL PIPE SUPPORT DETAILWATER PRESSURE REG. STATION DETAIL NO SCALE TO FIXTURES FLOOR BALL VALVE (TYP.) PRESSURE GAGE, 0-120 PSI, LIQUID FILLED (TYP.) TO S T R E E T SEE FLOOR PLAN FOR SIZE SEE FLOOR PLAN FOR SIZE PRESSURE REDUCING VALVE BACKFLOW REDUCE PRESSURE DEVICE NOTE: INSTALL DOUBLE CHECK OR REDUCED PRESSURE BACKFLOW DEVICE AS REQUIRED BY CODE. WATER METER XXX NO SCALE GAS PRESSURE REGULATOR DETAIL NO SCALE GAS PRESSURE REGULATOR 2# TO 7" WC CAPPED PRESSURE TEE (TYP.) MANUAL MAIN SHUT OFF VALVE PROVIDE ESCHUCEON PLATE AROUND PIPING FLEXIBLE GAS CONNECTOR 18" MAX GROUND JOINT UNION EQUIPMENT DRIP LEG SAME SIZE AS PIPE PLUMBING FIXTURE SCHEDULE SYMBOL DESCRIPTION COLD HOT VENT WASTE 1/2"1/2"1-1/2"2" 1/2"1/2"1-1/2"2"BREAK AREA SINK: SINK TO BE SELECTED BY OWNER. PROVIDE WITH ISOLATION VALVES, SS HOSES, P-TRAP 1/2"WALL BOX: OATEY METAL ICE MAKER, 1/4 TURN BRASS HAMMER VALVE 1/2"--2"3"WATER CLOSET: AMERICAN STANDARD 2467.100, BALL VALVE, SS FLEX HOSE, OPEN SEAT --1-1/2"2" LAV-1 S-1 WB-1 WC-1 3/4"------HOSE BIBB: WATTS HY-420, NON FREEZE, VACUUM BREAKERHB-1 DROP IN: AMERICAN STANDARD AQUALYN 0475.047, TOTO TEL101-D10ET FAUCET, ISOLATION VALVES, SS HOSES, HANDICAP COVER, P-TRAP 1/2"1/2"1-1/2"2" ONE PIECE ADA COMPLIANT SMOOTH WALL SHOWER INSERT EQUAL TO BEST BATH 4LRS3636B5B WITH GRAB BARS, FOLDING SEAT, CENTER DRAIN. COORDINATE THRESHOLD HEIGHT WITH FIELD CONDITIONS. SHR-1 3/4" URINAL: AMERICAN STANDARD 6590.001EC WITH 6063013.002 BATTERY POWERED SENSOR FLUSH VALVE(0.125 GPF) --1-1/2"2"UR-1 COT T O N W AR C H I T E C T U R A L G R O U P OO D Ph : ( 2 0 8 ) 2 5 1 - 1 9 6 7 ro s s i t e r a r c h @ a o l . c o m NC A R B C E R T I F I E D ME M B E R : A M E R I C A N I N S T I T U T E O F A R C H I T E C T S MA R S H A L L S . R O S S I T E R - A R C H I T E C T , A I A Ro s s i t e r A r c h i t e c t W r e AR STAMP: SH E E T T I T L E PROJECT NO: TCH RR 202314 2023 DRAWN BY: CHECKED BY: COPYRIGHT: AV E O S O L A R B U I L D I N G RE M O D E L PR O J E C T L O C A T I O N : 46 0 W 4 T H S RE X B U R G , I D A H O 8 3 4 4 0 Cottonwood Architectural Group, LLC reserves all rights to plans, drawings and ideas and all modifications. These plans are not to be copied, changed and or reproduced unless with express written consent of Cottonwood Architectural Group, LLC. Purchasers of these plans are limited to a single use of construction. Before starting construction the Purchaser(s), Builder(s), Subcontracer(s), and Supplier(s) must verify according to common best practices in their specific field whether there be any error in the plans that may need to be addressed and/or corrected. The Purchaser(s) or their agreed agent is responsible to secure and pay for any required structural, electrical, civil, mechanical, or other necesssary engineering as dictated by their local Authority Having Jurisdiction (AHJ). If the Purchaser(s) or their agreed agent find errors in the drawings, they must report them to Cottonwood Architectural Group, LLC and allow adequate time for correction of the errors to ensure project success. CO T T O N W O O D A R C H ' L G R O U P , L L C 53 5 N 4 0 3 0 E , R i g b y , I D 8 3 4 4 2 EM A I L : de s i g n @ c o t t o n w o o d a r c h . c o m TE L : 20 8 - 3 5 1 - 5 2 4 0 Gate City E N G I N E E R I N G S E R V I C E S 3 4 0 E . C L A R K S T . P O C A T E L L O , I D 8 3 2 0 4 2 0 8 .2 2 1 .9 5 0 6 RE V I E W PROJECT NO. 2383 P5 . 1 Sh e e t : 18 o f 1 8 PL U M B I N G D E T A I L S & S C H E D U L E