HomeMy WebLinkAboutAPPROVED DETAIL & ELEVATIONS 4.28.2023 - 23-00193 - 1077 Cypress Loop - New SFRAuthor Name Author Email Author Phone No.:
Larry Beesley Larry.Beesley@rexburg.org 208-372-2176
Description : 1077 Cypress Loop - New SFR
Address : 1077 Cypress Loop
Record Type : New Single Family Residence
Document Filename : BUILDING PLAN - CONSTRUCTION DETAIL & ELEVATIONS (REV. 1) 4.28.2023.pdf
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report
Approved
# 23-00193
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
Pg 1 Free Text Larry Beesley : Building Open 1 City ordnance requires 2 # 4 bar in the top 12", of an 8' or
taller wall.
Pg 1 Stamp Larry Beesley : Building Open 1 Approved - Building Inspector
Pg 2 Stamp Larry Beesley : Building Open 2 Approved - Building Inspector
Pg 3 Stamp Larry Beesley : Building Open 3 Approved - Building Inspector
Pg 3 Free Text Larry Beesley : Building Open 3 Roof Ventilation as per R806
Pg 3 Free Text Larry Beesley : Building Open 3 Street Number
Displayed on House
Pg 4 Stamp Larry Beesley : Building Open 4 Approved - Building Inspector
Pg 4 Free Text Larry Beesley : Building Open 4 Roof Trusses (designed according to R802.10.1) 35 # Snow and
90 mph winds (Local Conditions)
Pg 4 Free Text Larry Beesley : Building Open 4 Ground Surface to Slope away from Foundation a minimum of
6" within first 10 ft.
Pg 5 Stamp Larry Beesley : Building Open 5 Approved - Building Inspector
Pg 6 Stamp Larry Beesley : Building Open 6 Approved - Building Inspector
New Single Family Residence
All mark ups and redlines for hold down etc. must be followed.
Approval of plans does not constitute approval of variance from code
Powered by TCPDF (www.tcpdf.org)
City ordnance requires 2 # 4 bar in the top 12", of an 8' or taller wall.
8 foot foundation
wall (basement)
9 foot
exterior wall
5/12 Roof Pitch
4 foot foundation
wall (garage)
Finished
grade 16"
below top of
foundation
wall. Slope
min. 1 foot in
the first 10
feet from the
home.
R oof V entilation as per R 80 6
S treet N um ber
G round S urface to S lope away from
F oundation a m inim um of 6 " within
first 10 ft.
R oof T russes (desig ned according to R 80 2.10 .1) 3 5 # S now and 9 0 m ph winds (L ocal Conditions)