HomeMy WebLinkAboutPLANS - 23-00981 - Mo'Bettahs Restaurant - Fire ConstructionUtah Office REGION 87 PHONE: (801) 878 - 3677 EMAIL: reg87@captiveaire.com FOR QUESTIONS, CALL THE HOOD INFORMATION - JOB#6325918 1 2 H-1 H-2 5424 ND-2 5424 ND-2 CAPTIVEAIRE CAPTIVEAIRE 10' 10" 7' 9" 600 DEG 600 DEG I I HEAVY HEAVY 300 175 3250 1356 4" 4" 18" 12" 3250 1356 1839 1727 -1.208" -0.581" 430 SS WHERE EXPOSED 430 SS WHERE EXPOSED ALONE ALONE ALONE ALONE HOOD NO TAG MODEL MANUFACTURER LENGTH MAX COOKING TEMP TYPE APPLIANCE DUTY DESIGN CFM/FT TOTAL EXH CFM EXHAUST PLENUM RISER(S) WIDTH LENG HEIGHT DIA CFM VEL SP HOOD CONSTRUCTION HOOD CONFIG END TO END ROW HOOD INFORMATION 1 2 H-1 H-2 CAPTRATE SOLO FILTER CAPTRATE SOLO FILTER 8 5 20" 20" 16" 16" 85% SEE FILTER SPEC 85% SEE FILTER SPEC 4 3 L55 SERIES E26 L55 SERIES E26 NO NO RIGHT 12"x54"x24"TANK FS 4.0/4.0/4.0 DCV-2111 1 LIGHT 1 FAN YES YES 493 LBS 767 LBS HOOD NO TAG FILTER(S) TYPE QTY HEIGHT LENGTH EFFICIENCY @ 7 MICRONS LIGHT(S) QTY TYPE WIRE GUARD UTILITY CABINET(S) LOCATION SIZE FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL # SWITCHES QUANTITY FIRE SYSTEM PIPING HOOD HANGING WEIGHT HOOD OPTIONS 1 2 H-1 H-2 FIELD WRAPPER 4.00" HIGH FRONT. BACKSPLASH 122.00" HIGH X 132.00" LONG 430 SS VERTICAL. LEFT SIDESPLASH 122.00" HIGH X 40.00" LONG 430 SS VERTICAL. RIGHT SIDESPLASH 122.00" HIGH X 48.00" LONG 430 SS VERTICAL. RIGHT END STANDOFF (FINISHED) 1" WIDE 54" LONG INSULATED. LEFT END STANDOFF (FINISHED) 1" WIDE 54" LONG INSULATED. WRAPPER CHANNEL - LEFT, RIGHT. BACKSPLASH - INSIDE CORNER 122.00" HIGH X 2.00" LEG LENGTH 430 SS VERTICAL. BACKSPLASH - INSIDE CORNER 122.00" HIGH X 2.00" LEG LENGTH 430 SS VERTICAL. STRUCTURAL FRONT PANEL. WALL END CAP 122.00" HIGH X 5.00" WALL WIDTH, 2.00" LEGS 430 SS. WALL END CAP 122.00" HIGH X 5.00" WALL WIDTH, 2.00" LEGS 430 SS. RIGHT WALL AS END PANEL. LEFT WALL AS END PANEL. FIELD WRAPPER 4.00" HIGH FRONT, RIGHT. BACKSPLASH 122.00" HIGH X 124.00" LONG 430 SS VERTICAL. LEFT END STANDOFF (FINISHED) 1" WIDE 54" LONG INSULATED. RIGHT QUARTER END PANEL 23" TOP WIDTH, 0" BOTTOM WIDTH, 23" HIGH 430 SS. RISER SENSOR INSTALL 6IN PLEN. LEFT WALL AS END PANEL. HOOD NO TAG OPTION PATENT NUMBERS EXHAUST HOODS ND-2/BD-2/SND-2 (CANADA) - CA PATENT 2520435 C. SYSTEM DESIGN VERIFICATION (SDV) IF ORDERED, CAS SERVICE WILL PERFORM A SYSTEM DESIGN VERIFICATION (SDV) ONCE ALL EQUIPMENT HAS HAD A COMPLETE START UP PER THE OPERATION AND INSTALLATION MANUAL. TYPICALLY, THE SDV WILL BE PERFORMED AFTER ALL INSPECTIONS ARE COMPLETE. ANY FIELD RELATED DISCREPANCIES THAT ARE DISCOVERED DURING THE SDV WILL BE BROUGHT TO THE ATTENTION OF THE GENERAL CONTRACTOR AND CORRESPONDING TRADES ON SITE. THESE ISSUES WILL BE DOCUMENTED AND FORWARDED TO THE APPROPRIATE SALES OFFICE. IF CAS SERVICE HAS TO RESOLVE A DISCREPANCY THAT IS A FIELD ISSUE, THE GENERAL CONTRACTOR WILL BE NOTIFIED AND BILLED FOR THE WORK. SHOULD A RETURN TRIP BE REQUIRED DUE TO ANY FIELD RELATED DISCREPANCY THAT CANNOT BE RESOLVED DURING THE SDV, THERE WILL BE ADDITIONAL TRIP CHARGES. DURING THE SDV, CAS SERVICE WILL ADDRESS ANY DISCREPANCY THAT IS THE FAULT OF THE MANUFACTURER. SHOULD A RETURN TRIP BE REQUIRED, THE GENERAL CONTRACTOR AND APPROPRIATE SALES OFFICE WILL BE NOTIFIED. THERE WILL BE NO ADDITIONAL CHARGES FOR MANUFACTURER DISCREPANCIES. Hood) (30" High studs on the inside wall of the hood Grease Cup will be supported by 2 concealed grease trough and into this HANGING ANGLE 1/2 Pint Grease Cup Detail ONE ABOVE AND TWO BELOW 1/2" DIA. HEAVY DUTY NUT ROD AND NUTS TO BE SUPPLIED BY INSTALLING CONTRACTOR IN THE FOLLOWING LOCATIONS ND-2 HANGING ANGLE DETAIL HANGING ANGLES WILL BE LOCATED FROM DIM FRONT HANGING ANGLE LOCATIONS Hood) Condensate 2.25"2.25" Wall Back Shelf 4.166" Exhaust Only With MUA 2.25" 2.25" 4.166" Only Exhaust With MUA 2.25" 2.25" HOOD STYLE FOR WALL CANOPIES FROM DIM REAR (24" High DIM FROM FRONT HANGING ANGLE IS PRE-PUNCHED AT FACTORY * removable cup. ANGLE THROUGH ANOTHER HANGING CONNECTED TO ROOF JOIST 1/2" DIA. ALL THREAD ROD The grease will drain through a 2.25" 2.25" 2.25" 2.25" CALCULATIONS UTILIZED VELOCITY OF 1600-1800 FPM AND A SUPPLY VELOCITY OF 1000 FPM PLEASE CONSULT FACTORY FOR MAXIMUM ALLOWABLE DUCT SIZES FPM(*) DUCT DEPTH TOTAL DUCT AREA EXHAUST CFM=LENGTH OF HOOD X CFM/LIN.FT. (LOAD) SUPPLY CFM=EXHAUST CFM X PERCENTAGE REQUIRED CAPTIVE-AIRE VENTILATOR DUCT SIZES ARE CALCULATED USING AN EXHAUST DUCT LENGTH= TOTAL DUCT AREA=144 X * CFM BUILDING CODES 2" Captrate Grease-Stop Solo Filter RESISTANCE VS. AIRFLOW 1.6 1.4 1 1.2 1000800600 0.8 0.4 0.6 4002000 0 0.2 RE S I S T A N C E ( i n . H 2 0 ) AIRFLOW (cfm) CAPTRATE Filter Detail R R Captrate Grease-Stop Solo Filter CAPTIVE-AIRE HOODS ARE BUILT IN COMPLIANCE WITH: D R T TA S INA C IS L NOI D E T M Intertek SI ETL ETL SANITATION E.T.L. LISTED 3054804-001 ETL IS LISTED TO ULC STANDARDS * * * NFPA #96 * R NSF * SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R C U S 6325918 MASTER DRAWING SLS 1 12/8/2023 Mo ' B e t t a h s - R e x b u r g 3/4" = 1'-0" 46 1 N o r t h 2 n d E a s t , Ut a h O f f i c e 26 9 8 S . R e d w o o d R d . , S u i t e S , W e s t V a l l e y , U T , 8 4 1 1 9 P H O N E : ( 8 0 1 ) 8 7 8 - 3 6 7 7 F A X : 9 1 9 2 2 7 5 9 5 3 E M A I L : r e g 8 7 @ c a p t i v e a i r e . c o m Re x b u r g , I D , 8 3 4 4 0 10' 10"NOM./10' 10.00"OD. 11'-0.00" OVERALL LENGTH 54" 1" LAYER OF INSULATION FACTORY INSTALLED IN 1.00" END STANDOFF MEETS 0" REQUIREMENTS CLEARANCE TO COMBUSTIBLE SURFACES. 1" 1" LAYER OF INSULATION FACTORY INSTALLED IN 1.00" END STANDOFF MEETS 0" REQUIREMENTS CLEARANCE TO COMBUSTIBLE SURFACES. 1" 3" § 53"77" 12" ∅18" U.L. LISTED L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY. INSTALLER MUST CONFIRM HOOD IS INSTALLED SUCH THAT THE SPECIFIED WALL, ACTING AS AN END PANEL, IS MATED TIGHT TO THE CORRECT END OF HOOD TO ACHIEVE A REDUCED MINIMUM EXHAUST CFM LISTING. NON-COMPLIANCE WILL NULLIFY THE ETL LISTING, VOID THE MANUFACTURER'S WARRANTY, AND HOLD THE CONTRACTOR LIABLE FOR ANY AND ALL LOSSES, COSTS, AND EXPENSES RELATED TO THE NON-CONFORMANCE OF THE MANUFACTURER'S SPECIFIED INSTRUCTION. THE WALL ACTING AS AN END PANEL MUST EXTEND NO LESS THAN 20" FROM THE INTERSECTING WALL ON WHICH HOOD IS MOUNTED AND MUST EXTEND NO LESS THAN 20" UNDER BOTTOM OF HOOD TO BE ELIGIBLE FOR REDUCED MINIMUM EXHAUST CFM LISTING. PLAN VIEW - HOOD #1 (H-1) 10' 10.00" LONG 5424ND-2 7' 9"NOM./7' 9.00"OD. 8'-10.00" OVERALL LENGTH 54" 12" UTILITY CABINET. SC - 2 0 X 1 8 X 8 . 6 2 B O X 1" LAYER OF INSULATION FACTORY INSTALLED IN 1.00" END STANDOFF MEETS 0" REQUIREMENTS CLEARANCE TO COMBUSTIBLE SURFACES. 1" 3" § 46 1/2"46 1/2" 10" ∅12" U.L. LISTED L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY. INSTALLER MUST CONFIRM HOOD IS INSTALLED SUCH THAT THE SPECIFIED WALL, ACTING AS AN END PANEL, IS MATED TIGHT TO THE CORRECT END OF HOOD TO ACHIEVE A REDUCED MINIMUM EXHAUST CFM LISTING. NON-COMPLIANCE WILL NULLIFY THE ETL LISTING, VOID THE MANUFACTURER'S WARRANTY, AND HOLD THE CONTRACTOR LIABLE FOR ANY AND ALL LOSSES, COSTS, AND EXPENSES RELATED TO THE NON-CONFORMANCE OF THE MANUFACTURER'S SPECIFIED INSTRUCTION. THE WALL ACTING AS AN END PANEL MUST EXTEND NO LESS THAN 20" FROM THE INTERSECTING WALL ON WHICH HOOD IS MOUNTED AND MUST EXTEND NO LESS THAN 20" UNDER BOTTOM OF HOOD TO BE ELIGIBLE FOR REDUCED MINIMUM EXHAUST CFM LISTING. PLAN VIEW - HOOD #2 (H-2) 7' 9.00" LONG 5424ND-2 3" INTERNAL STANDOFF. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. § EXHAUST RISER. HANGING ANGLE. L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE). BACKSPLASH 122.00" HIGH X 132.00" LONG. FIELD WRAPPER 4.00" HIGH (SEE HOOD OPTIONS TABLE). LEFT AND RIGHT WALL AS END PANELS. EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54" SECTION VIEW - MODEL 5424ND-2 HOOD - #1 (H-1) IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. 3" INTERNAL STANDOFF. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. § EXHAUST RISER. HANGING ANGLE. L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE). BACKSPLASH 122.00" HIGH X 124.00" LONG. FIELD WRAPPER 4.00" HIGH (SEE HOOD OPTIONS TABLE). 23" 23" RIGHT QUARTER END PANEL. LEFT WALL AS END PANEL. EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54" SECTION VIEW - MODEL 5424ND-2 HOOD - #2 (H-2) IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R C U S 6325918 MASTER DRAWING SLS 2 12/8/2023 Mo ' B e t t a h s - R e x b u r g 3/4" = 1'-0" 46 1 N o r t h 2 n d E a s t , Ut a h O f f i c e 26 9 8 S . R e d w o o d R d . , S u i t e S , W e s t V a l l e y , U T , 8 4 1 1 9 P H O N E : ( 8 0 1 ) 8 7 8 - 3 6 7 7 F A X : 9 1 9 2 2 7 5 9 5 3 E M A I L : r e g 8 7 @ c a p t i v e a i r e . c o m Re x b u r g , I D , 8 3 4 4 0 FIRE SYSTEM INFORMATION - JOB#6325918 1 TANK FS 4.0/4.0/4.0 60 55 FIRE CABINET RIGHT RIGHT, HOOD 2 FIRE SYSTEM NO TAG TYPE SIZE MAX FP DESIGN FP INSTALLATION SYSTEM LOCATION ON HOOD GAS VALVE(S) 1 SC ELECTRICAL 1.500 CAPTIVEAIRE SYSTEMS FIRE SYSTEM NO TAG TYPE SIZE SUPPLIED BY FIRE SYSTEM PARTS LIST KEY 1 0 - 0 - TANK FIRE SUPPRESSION POST-DISCHARGE PROCEDURE UTILITY CABINET LABEL SHEET. 0 - 0 - TANK FIRE SUPPRESSION MAINTENANCE GUIDE UTILITY CABINET LABEL SHEET. 0 - 0 - 12-F28021-32144-OT-360 DUCT FIRE THERMOSTAT WITH 12 FOOT WIRE LEADS. NO, CLOSE ON TEMP RISE AT 360°F. 0 - 0 - 32-00002 QUIK SEAL - 1/2" (UL). 0 - 0 - 361091 3/8" BRASS PLUG. 0 - 0 - 4429K153 1/2" MALE NPT TO 1/2" FEMALE NPT ELBOW, BRASS. 0 - 0 - 4429K422 1/2" X 1/4" BRASS REDUCING BUSHING. 0 - 0 - 79425 3/8" NPT FEMALE TO 1/2" MALE PROPRESS ADAPTER. 0 - 0 - 79525 1/2" 90 PRO-PRESS ELBOW WITH 1/2” NPT FEMALE CONNECTION, VIEGA. 0 - 0 - 79580 1/2" X 1/2" PRO-PRESS TEE X 1/2” NPT FEMALE CONNECTION, VIEGA. 0 - 0 - 87-120042-001 SECONDARY ACTUATOR VALVE (SVA) - SINGLE ACTUATOR, REQUIRES PRIMARY RELEASE ACTUATOR, TANK FIRE SUPPRESSION. 0 - 0 - 87-120045-001 HOSE, SECONDARY ACTUATOR HOSE, 7.5" BRAIDED STAINLESS STEEL, TANK FIRE SUPPRESSION. 0 - 0 - 87-300001-001 TANK - PRESSURIZED TANK USED FOR TANK FIRE SUPPRESSION. 0 - 0 - 87-300030-001 PRIMARY ACTUATOR KIT (PAK) - ACTUATOR AND RELEASE SOLENOID ASSEMBLY, ONE NEEDED PER FIRE SYSTEM, SUPERVISED, TANK FIRE SUPPRESSION. 0 - 0 - 87-300152-001 HARDWARE, SVA BOLTS, TANK FIRE SUPPRESSION. 0 - 0 - 9055455PC PRO PRESS 1/2 PRESS X PRESS 90 ELBOW LD. 0 - 0 - 9097200PC PRO PRESS PC611 1/2 PRESS TEE LD. 0 - 0 - 98694A115 HARDWARE, DATANKLOCK LOCKING BRACKET SQUARE NUTS 5/16" ZINC, TANK FIRE SUPPRESSION. 0 - 0 - A0034332 JUNCTION BOX FOR MANUAL PULL STATION. 1.5" DEEP BACK BOX, RED COLOR. 0 - 0 - A31484 1/4" NPT SCHRADER VALVE AND CAP, JB INDUSTRIES. 1/4" FLARE X 1/4" MPT HALF UNION. USED ON TANK SERVICE PORT. 0 - 0 - BI145 3/8" BLACK IRON 90 ELL. 0 - 0 - DATANKLOCK DISCHARGE ADAPTER TANK LOCKING PLATE FOR FIRE SYSTEM TANK INSTALLATION IN UTILITY CABINETS, TANK FIRE SUPPRESSION. 0 - 0 - SLPCON-03FT SUPERVISED LOOP CONNECTION KIT. CONTAINS THE PARTS NEEDED TO CONNECT THE SUPERVISED LOOP BETWEEN END TO END HOODS WITH LESS THAN A 2' GAP. KIT CONTAINS 5 FEET OF BLACK MG WIRE, 5 FEET OF TAN MG WIRE, 3 FEET OF FLEXIBLE CONDUIT, AND TWO 7/8" CONNECTORS. 0 - 0 - SLPCON-15FT SUPERVISED LOOP CONNECTION KIT. CONTAINS THE PARTS NEEDED TO CONNECT THE SUPERVISED LOOP BETWEEN END TO END HOODS WITH LESS THAN A 14' GAP OR BACK TO BACK HOODS. KIT CONTAINS 17 FEET OF BLACK MG WIRE, 17 FEET OF TAN MG WIRE, 15 FEET OF FLEXIBLE CONDUIT, AND TWO 7/8" CONNECTORS. 0 - 0 - TANK STRAP TANK STRAP - USED FOR TANK FIRE SUPPRESSION. 0 - 0 - TFS-UCTANKBRACKET TANK BRACKET FOR FIRE SYSTEM TANK INSTALLATION IN UTILITY CABINETS, TANK FIRE SUPPRESSION. 0 - 0 - WK-283952-000 DISCHARGE ADAPTER, TANK FIRE SUPPRESSION. 16 - 16 - 79210 1/2" X 3/8" NPT MALE ADAPTER, VIEGA. 16 - 16 - OL-F NOZZLE - TANK PROTECTION APPLIANCE COVERAGE NOZZLE (INCLUDES METAL BLOW OFF CAP, LANYARD, USED WITH CHROME-PLATED PIPE). 26 - 26 - QSA-3/8 QUIK SEAL - 3/8" (UL). 34 - 34 - A0034331 24VDC SINGLE ACTION MANUAL ACTUATION DEVICE (PUSH/PULL STATION) WITH PROTECTIVE COVER, ONE (1) NORMALLY OPEN CONTACT. RED COLOR. 1 1 2 2 3 3 2 3 2 3 2 2 3 1 12 11 11 6 1 2 5 3 1 2 9 3 3 12 12 12 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 FIRE SYSTEM NO TAG KEY NUMBER - PART DESCRIPTION QTY BY FACTORY QTY BY DIST SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R C U S 6325918 MASTER DRAWING SLS 3 12/8/2023 Mo ' B e t t a h s - R e x b u r g 3/4" = 1'-0" 46 1 N o r t h 2 n d E a s t , Ut a h O f f i c e 26 9 8 S . R e d w o o d R d . , S u i t e S , W e s t V a l l e y , U T , 8 4 1 1 9 P H O N E : ( 8 0 1 ) 8 7 8 - 3 6 7 7 F A X : 9 1 9 2 2 7 5 9 5 3 E M A I L : r e g 8 7 @ c a p t i v e a i r e . c o m Re x b u r g , I D , 8 3 4 4 0 FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. 12" ∅18" HOOD FRONT HOOD BACK HOOD # 1 (H-1) JOB # 6325918 FS # 1 MODEL: ND-2 SIZE: 54"x24" LENGTH: 10' 10" TA N K O V E R L A P P I N G PR O T E C T I O N - 3 0 HI G H P R O X I M I T Y 11 8 . 0 0 " L X 3 0 . 0 0 " D DUCT S 360 OL-F OL-F OL-F 25.00" 21.50" OL-F 21.50" OL-F 21.50" OL-F 21.50" OL-F 21.50" OL-F NOZZLE HEIGHT 35-50" FROM COOKING SURFACE. (45.25") 17.80"23.60"23.60"23.60"23.60"17.80" SLPCON-15FT KIT FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. 10" ∅12" HOOD FRONT HOOD BACK HOOD # 2 (H-2) JOB # 6325918 FS # 1 MODEL: ND-2 SIZE: 54"x24" LENGTH: 7' 9" TA N K O V E R L A P P I N G PR O T E C T I O N - 3 0 HI G H P R O X I M I T Y 39 . 0 0 " L X 1 8 . 0 0 " D DUCT S 360 OL-F OL-F 25.00" 21.50" OL-F 21.50" OL-F NOZZLE HEIGHT 35-50" FROM COOKING SURFACE. (45.25") 57.75"19.50"15.75" SLPCON-15FT KIT SLPCON-03FT KIT - SYSTEM REQUIRES A MINIMUM OF 7 FT OF EQUIVALENT PIPE LENGTH BETWEEN TANK AND NEAREST APPLIANCE NOZZLE FOR MOST APPLIANCES. EACH 90 DEGREE ELBOW ADDS 1.3 FT OF EQUIVALENT LENGTH. SEE MANUAL FOR DETAILS 1 631 1 3 7 6 2 5 ALTERNATE FIELD-CONNECTION POINT PL E N U M PL E N U M PL E N U M NOTES - FIELD PIPE DROPS AS SHOWN PIPING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS. - FIELD INSTALLED DROP: FACTORY WILL PROVIDE QTY 2 60IN LONG PIECES OF CHROME PLATED PIPING SHIPPED LOOSE TO BE FIELD-INSTALLED. - SHIP LOOSE DROP: FACTORY WILL PROVIDE THE EXACT CHROME PIPE LENGTH NEEDED SHIPPED LOOSE TO BE FIELD-INSTALLED. - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - OVERLAPPING COVERAGE SHALL NOT BE USED ON ANY APPLIANCE WITH AN OBSTRUCTION. - IF APPLICABLE, EXTENDED PRE-PIPED DROPS ARE SHIPPED LOOSE. - FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. - THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS. - OL-F NOZZLE PART NUMBER REPLACES 3070-3/8H-10-SS JOB #: 6325918. JOB NAME: MO' BETTAHS - REXBURG. SYSTEM SIZE: TANK-SP-3 DESIGN FP: 55. MAXIMUM FP: 60. HOOD # 1 10' 10.00" LONG x 54" WIDE x 24" HIGH. RISER # 1 SIZE: 18" DIA. HOOD # 1 METAL BLOW-OFF CAPS INCLUDED. HOOD # 2 7' 9.00" LONG x 54" WIDE x 24" HIGH. RISER # 1 SIZE: 12" DIA. HOOD # 2 METAL BLOW-OFF CAPS INCLUDED. - HEAVY-DUTY APPLIANCES (RATED 600°F) WILL REQUIRE AN ADDITIONAL DOWNSTREAM FIRESTAT IN THE EVENT THAT THE DUCTWORK CONTAINS ANY HORIZONTAL RUNS OVER 25 FT IN LENGTH. - MEDIUM TO LIGHT-DUTY APPLIANCES (RATED 450°F) WILL NOT REQUIRE ANY ADDITIONAL DOWNSTREAM DETECTION. PRESSURE SUPERVISION SWITCH. PRIMARY ACTUATOR RELEASE. 4 GALLON TANK. 7 6 5 4 2 1 LEGEND - FIRE CABINET TANK SYSTEM PRIMARY HOSE ASSEMBLY. SECONDARY ACTUATOR RELEASE.3 SECONDARY HOSE ASSEMBLY. REMOTE MANUAL ACTUATION DEVICE. 3" INTERNAL STANDOFF. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. § EXHAUST RISER. HANGING ANGLE. L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE). BACKSPLASH 122.00" HIGH X 132.00" LONG. FIELD WRAPPER 4.00" HIGH (SEE HOOD OPTIONS TABLE). LEFT AND RIGHT WALL AS END PANELS. EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54" SECTION VIEW - MODEL 5424ND-2 HOOD - #1 IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. 21 1/2" 3" INTERNAL STANDOFF. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. § EXHAUST RISER. HANGING ANGLE. L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE). BACKSPLASH 122.00" HIGH X 124.00" LONG. FIELD WRAPPER 4.00" HIGH (SEE HOOD OPTIONS TABLE). 23" 23" RIGHT QUARTER END PANEL. LEFT WALL AS END PANEL. EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54" SECTION VIEW - MODEL 5424ND-2 HOOD - #2 IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. 21 1/2" INCLUDES: FIELD INSTALLATION AND HOOKUP DURING NORMAL BUSINESS HOURS BY CERTIFIED INSTALLERS ONLY IN THE LOCATION NOTED ABOVE, TWO SITE VISITS ONLY (ONE VISIT TO SET PULL STATION & SYSTEM HOOKUP AND ONE VISIT FOR ONE TEST; ADDITIONAL VISITS WILL RESULT IN ADDITIONAL CHARGES), ONE MECHANICAL OR ELECTRICAL GAS VALVE PER SYSTEM AT A MAXIMUM SIZE OF 2", PERMIT, AND SYSTEM TEST. EXCLUDES: UNION LABOR & PREVAILING WAGE (LABOR & WAGES WILL BE ADDED IF APPLICABLE), GAS VALVE INSTALLATION, ELECTRICAL HOOKUP AND CONNECTIONS, HANGING OF FIRE CABINET, SHUNT TRIP, HANDHELD EXTINGUISHER(S), ON-SITE RE-PIPING DUE TO EQUIPMENT LAYOUT CHANGES. VOLTAGESIZE TYPE GAS VALVE SIZING GAS VALVE DIMENSIONS DIM "A"DIM "B"DIM "C"DIM "D"DIM "F"DIM "G" PART NUMBERS GAS VALVES AND STRAINERS INSTALLATION MIN. INLET PRESSURE MAX. INLET PRESSURE FLOW AT 1 IN.W.C. DROP NATURAL GAS FLOW AT 1 IN.W.C. DROP PROPANE MOUNTING ORIENTATION GAS VALVE PART NUMBER STRAINER PART NUMBER GAS VALVE/STRAINER KIT ELECTRICAL 1-1/2"120 VAC 4417K6782142757-5/8"6-3/8"5-3/4"6-3/16"14-1/8"12-5/16"(SC)EGVA1-1/2GAS VALVE FOR FS#1 0 PSI (0 IN.W.C.) 5 PSI (138 IN.W.C.) 2,406,000 BTU/HR 1,561,219 BTU/HR HORIZONTAL/ VERTICAL FLOW. ELECTRIC GAS VALVE. STRAINER. 4" MIN. DIM "G" DIM "D" DIM "A" DIM "F" DIM "C" DIM "B" ALL GAS VALVES/STRAINERS TO CALCULATE GAS FLOW FOR OTHER THAN 1 IN.W.C. PRESSURE DROP NEW BTU/HR = (BTU/HR AT 1 IN.W.C. PRESSURE DROP) X NEW PRESSURE DROP 0.5 TO CALCULATE GAS FLOW FOR OTHER THAN 0.64 SPECIFIC GRAVITY NEW BTU/HR = (BTU/HR AT 0.64) X (0.64 / NEW SPECIFIC GRAVITY) 0.5 . CALCULATIONS PROPER CLEARANCE MUST BE PROVIDED IN ORDER TO SERVICE THE STRAINERS A MINIMUM OF 4" CLEARANCE DISTANCE MUST BE PROVIDED AT THE BASE OF THE STRAINER CUSTOMER MUST VERIFY BTU CONSUMPTION AS WELL AS PRESSURE RATING SPECIFIC GRAVITY OF NATURAL GAS = 0.64, SPECIFIC GRAVITY OF LP = 1.52. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R C U S 6325918 MASTER DRAWING SLS 4 12/8/2023 Mo ' B e t t a h s - R e x b u r g 1/2" = 1'-0" 46 1 N o r t h 2 n d E a s t , Ut a h O f f i c e 26 9 8 S . R e d w o o d R d . , S u i t e S , W e s t V a l l e y , U T , 8 4 1 1 9 P H O N E : ( 8 0 1 ) 8 7 8 - 3 6 7 7 F A X : 9 1 9 2 2 7 5 9 5 3 E M A I L : r e g 8 7 @ c a p t i v e a i r e . c o m Re x b u r g , I D , 8 3 4 4 0 EXHAUST FAN INFORMATION - JOB#6325918 1 2 1 1 DU180HFA DU85HFA CAPTIVEAIRE CAPTIVEAIRE 3250 1356 1.708 1.081 1439 1310 ODP,PREMIUM TEAO-ECM 3.000 1.000 1.9480 0.3730 3 1 208 208 9.5 6.9 751 FPM 429 FPM 202 99 23.8 10.7 FAN UNIT NO TAG QTY FAN UNIT MODEL #MANUFACTURER CFM ESP RPM MOTOR ENCL HP BHP PHASE VOLT FLA DISCHARGE VELOCITY WEIGHT (LBS) SONES MUA FAN INFORMATION - JOB#6325918 3 1 A2-D.500-20D 20MF-2-MOD A2-D.500 2000 3685 1.100 1790 ODP,PREMIUM 5.000 2.5940 3 208 15.0 20.9A 35A 5.22 90.0°F 61.0°F 71.0°F 61.0°F 985 20.1 FAN UNIT NO TAG QTY FAN UNIT MODEL #BLOWER HOUSING MIN CFM DESIGN CFM ESP RPM MOTOR ENCL HP BHP PHASE VOLT FLA MCA MOCP EVAP FLOW RATE (Gal/Hr) EVAP COOLER ENTERING DB TEMP EVAP COOLER ENTERING WB TEMP EVAP COOLER LEAVING DB TEMP EVAP COOLER LEAVING WB TEMP WEIGHT (LBS) SONES GAS FIRED MAKE-UP AIR UNIT(S) 3 287664 264651 81°F 7 IN. W.C. - 14 IN. W.C.NATURAL 92 FAN UNIT NO TAG INPUT BTUs OUTPUT BTUs TEMP RISE REQUIRED INPUT GAS PRESSURE GAS TYPE BURNER EFFICIENCY(%) FAN OPTIONS 1 2 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 GREASE BOX FAN BASE CERAMIC SEAL - SHIP LOOSE - FOR GREASE DUCTS EXHAUST FAN HEAT BAFFLE UNIT MOUNTED VFD FOR USE WITH ECPM03 VFD MOUNTING BRACKET FOR DU/DR 180 - 200 2 YEAR PARTS WARRANTY GREASE BOX FAN BASE CERAMIC SEAL - SHIP LOOSE - FOR GREASE DUCTS ECM WIRING PACKAGE - PWM SIGNAL FROM ECPMO3 PREWIRE (TELCO MOTOR), CCW ROTATION 2 YEAR PARTS WARRANTY SIZE 2 TEMPERED COMMERCIAL DOWN DISCHARGE FOR DIRECT DRIVE AHUS INLET PRESSURE GAUGE, 0-35" MANIFOLD PRESSURE GAUGE, -5 TO 15" WC BUTTERFLY MOD VALVE OPTION FOR MOD SIZE 2 (1" MOD VALVE) SHIP LOOSE GAS STRAINER 1" MOTORIZED BACKDRAFT DAMPER FOR A2-D HOUSING - MEETS AMCA CLASS 1A RATING CONTROL PANEL ENCLOSURE HEATER 100W - RECOMMENDED FOR WINTER DESIGN TEMPERATURES LESS THAN 0°F IBT/MUA EVAP INTERLOCK FREEZE PROTECTION DRAIN KIT FOR EVAPORATIVE COOLERS FREEZE PROTECTION DRAIN KIT FOR IBT/MUA WITH EVAPORATIVE COOLERS SIZE 2 DIRECT FIRED HEATER LOW CFM PROFILE PACKAGE - USED ON HEATERS UNDER 2500 CFM UNIT MOUNTED VFD FOR USE WITH ECPM03 2 YEAR PARTS WARRANTY FAN UNIT NO TAG QTY DESCRIPTION FAN ACCESSORIES 1 2 3 YES YES YES FAN UNIT NO TAG EXHAUST GREASE CUP GRAVITY DAMPER WALL MOUNT SUPPLY SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT CURB ASSEMBLIES 1 2 3 # 1 # 2 # 3 # 3 52 LBS 41 LBS 90 LBS CURB CURB CURB RAIL 26.500"W X 26.500"L X 24.000"H VENTED HINGED. 23.000"W X 23.000"L X 24.000"H VENTED HINGED. 31.000"W X 79.000"L X 20.000"H INSULATED. 4.000"W X 4.000"L X 36.000"H. NO ON FAN WEIGHT ITEM SIZE HMI SCHEDULE UNIT NUMBER HMI #HMI LOCATION TEMP AVERAGING MODBUS ADDRESS FAN #3 HMI #1 - UNIT HMI # 1 MOUNTED IN UNIT NOT AVERAGED 55 - VARIABLE SPEED CONTROL. - THERMAL OVERLOAD PROTECTION (SINGLE PHASE). - HIGH HEAT OPERATION 300°F (149°C). EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. NORMAL TEMPERATURE TEST 26" 28" 37 3/8" 16 1/2" 2" 22 5/8" - INTERNAL WIRING. - ROOF MOUNTED FANS. - RESTAURANT MODEL. FEATURES: - DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS). TOP VIEW 37 3/8" 28" - NEMA 3R SAFETY DISCONNECT SWITCH. 33 3/4" GREASE DRAIN. - GREASE CLASSIFICATION TESTING. - UL705 AND UL762 AND ULC-S645 ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600°F (316°C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. 26" 26" ROOF OPENING DIMENSIONS. 24" 26 1/2" 20 GAUGE CONSTRUCTION. STEEL 3" FLANGE. 26 1/2" HINGE KIT VENTED CURB. FAN #1 DU180HFA - EXHAUST FAN OPTIONS - GREASE BOX. - FAN BASE CERAMIC SEAL - SHIP LOOSE - FOR GREASE DUCTS. - EXHAUST FAN HEAT BAFFLE. - UNIT MOUNTED VFD FOR USE WITH ECPM03. - VFD MOUNTING BRACKET FOR DU/DR 180 - 200. - 2 YEAR PARTS WARRANTY. FAN BASE ATTENTION: INSTALLER SHOULD SUPPLY ENOUGH ELECTRICAL CORD TO LET FAN MAKE FAN IN OPEN POSITION PROVIDED TO OPERATE THE HOOD LIGHTS AND FANS. A PRE-WIRED ELECTRICAL CONTROL PACKAGE SHALL BE GREASE BOX INSTALLATION CURB ATTACH GREASE BOX COVER TO THE CURB 3" BELOW USING (3) LONG (3/4" LG.) SCREWS AS SHOWN. TOP EDGE OF CURB. INSTALL GREASE PIPE AS SHOWN. GREASE BOX SEPARATOR GREASE BOX COVER ADDITIONAL FIRE SYSTEM ACTIVATED DRY CONTACTS. DOUBLE-DUAL FIRE SYSTEM MICROSWITCH CONNECTION. FOR SUPPLY FAN SHUTDOWN AND OTHER RELAY FOR INPUT/OUTPUT TERMINAL STRIPS, AND A TERMINAL FOR SUPPLIED BY THE ELECTRICAL CONTRACTOR. OVERLOAD ASSEMBLY FOR EACH FAN(OPTIONAL), NUMBERED SWITHCH(ES) AND RED-LIGHTED FAN SWITCH(ES), STARTER/ PACKAGE SHALL CONSIST OF SWITCH PANEL WITH LIGHT BETWEEN THE PRE-WIRE PACKAGE AND FAN(S) SHALL BE ONE RELAY IS WIRED TO MICROSWITCH (IN FIRE SYSTEM) CONNECTED TO THE NUMBERED TERMINAL STRIP. CONDUIT ELECTRICAL CONDUIT DROPS FROM THE FAN(S) SHALL BE ELECTRICAL PACKAGE NOTES 4. 3. 1. 2. GREASE PIPE COMPLETE SWING. HINGE KIT DETAIL FAN IN CLOSED POSITION GREASE BOX (OPTIONAL) GREASE PIPE (OPTIONAL) CURB "A" DETAIL FAN CURB (LEFT) PLATE FAN BASE PLATE (LEFT) FAN SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R C U S 6325918 MASTER DRAWING SLS 5 12/8/2023 Mo ' B e t t a h s - R e x b u r g 3/4" = 1'-0" 46 1 N o r t h 2 n d E a s t , Ut a h O f f i c e 26 9 8 S . R e d w o o d R d . , S u i t e S , W e s t V a l l e y , U T , 8 4 1 1 9 P H O N E : ( 8 0 1 ) 8 7 8 - 3 6 7 7 F A X : 9 1 9 2 2 7 5 9 5 3 E M A I L : r e g 8 7 @ c a p t i v e a i r e . c o m Re x b u r g , I D , 8 3 4 4 0 - VARIABLE SPEED CONTROL. - THERMAL OVERLOAD PROTECTION (SINGLE PHASE). - HIGH HEAT OPERATION 300°F (149°C). EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. NORMAL TEMPERATURE TEST 22 1/2" 24 3/4" 31 7/8" 14 7/8" 2" 23" - INTERNAL WIRING. - ROOF MOUNTED FANS. - RESTAURANT MODEL. FEATURES: - DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS). TOP VIEW 31 7/8" 24 3/4" - NEMA 3R SAFETY DISCONNECT SWITCH. 30 1/2" GREASE DRAIN. - GREASE CLASSIFICATION TESTING. - UL705 AND UL762 AND ULC-S645 ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600°F (316°C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. 22 1/2" 22 1/2" ROOF OPENING DIMENSIONS. 24" 23" 20 GAUGE CONSTRUCTION. STEEL 3" FLANGE. 23" HINGE KIT VENTED CURB. FAN #2 DU85HFA - EXHAUST FAN OPTIONS - GREASE BOX. - FAN BASE CERAMIC SEAL - SHIP LOOSE - FOR GREASE DUCTS. - ECM WIRING PACKAGE - PWM SIGNAL FROM ECPMO3 PREWIRE (TELCO MOTOR), CCW ROTATION. - 2 YEAR PARTS WARRANTY. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R C U S 6325918 MASTER DRAWING SLS 6 12/8/2023 Mo ' B e t t a h s - R e x b u r g 3/4" = 1'-0" 46 1 N o r t h 2 n d E a s t , Ut a h O f f i c e 26 9 8 S . R e d w o o d R d . , S u i t e S , W e s t V a l l e y , U T , 8 4 1 1 9 P H O N E : ( 8 0 1 ) 8 7 8 - 3 6 7 7 F A X : 9 1 9 2 2 7 5 9 5 3 E M A I L : r e g 8 7 @ c a p t i v e a i r e . c o m Re x b u r g , I D , 8 3 4 4 0 DIRECT FIRED (DF) PROFILE PLATE ASSEMBLY DIRECT FIRED PROFILE PLATE SPECIFICATIONS: DESCRIPTION: DIRECT FIRED BURNERS SHALL HAVE PATENTED (US PATENT NO.: US6629523B2), SELF-ADJUSTING PROFILE PLATES DESIGNED TO ENSURE PROPER AIR VELOCITY AND PRESSURE DROP ACROSS THE BURNER. PROFILE APPLICATION: SPRING-LOADED BURNER PROFILE PLATES ARE ENGINEERED TO AUTOMATICALLY REACT TO THE MOMENTUM OF A FRESH AIR STREAM, WITHOUT THE NEED FOR ANY MOTORS OR ACTUATORS TO MECHANICALLY ADJUST THEM. WITH THIS FEATURE, ALL DF UNITS ARE DESIGNED FOR DEMAND CONTROL VENTILATION (DCV) REQUIREMENTS. CERTIFICATIONS: ALL PROFILE PLATE ASSEMBLIES SHALL BE INCLUDED IN THE DF UNIT'S ETL LISTING AND COMPLY WITH COMBINED SAFETY STANDARDS ANSI Z83.4 AND CSA 3.7 (NON-RECIRCULATING DF HEATERS) AND ANSI Z83.18 GENERAL CONSTRUCTION: -PROFILE PLATES SHALL BE FORMED FROM G90 GALVANIZED STEEL. -PROFILE PLATES SHALL VARY IN SIZE PER UNIT. -PROFILE PLATES SHALL BE MOUNTED ALONG THE SAME PLANE AS THE DISCHARGE OF THE BURNER. -DESIGN SHALL INCORPORATE PROPERLY TORQUED, PERMANENTLY MOUNTED SPRING HINGES. PLATES SHALL ALLOW BURNERS TO ACHIEVE CLEAN COMBUSTION BY LIMITING BY-PRODUCT LEVELS TO A MAXIMUM OF 5PPM OF CARBON MONOXIDE (CO), AND 0.5PPM OF NITROGEN DIOXIDE (NO2). (RECIRCULATING DF HEATERS). -SPRING HINGES SHALL BE MADE FROM PLATED STEEL. DIRECT FIRED UNITS SHALL BE CONFIGURED WITH THE BLOWER MOUNTED DOWNSTREAM OF THE BURNER. THIS ARRANGEMENT WILL ENSURE A CONSISTENT AIRFLOW, REGARDLESS OF INLET AIR TEMPERATURE. FLEX CONDUIT FOR FIELD WIRING. 8 5/16"16" 6 1/8" 18 3/4" LIFTING LUG. 3 3/4" AIRFLOW. BLOWER/MOTOR ACCESS DOOR 24" SERVICE CLEARANCE REQ. 79" 16 1/4" SERVICE DISCONNECT SWITCH. AIRFLOW. 1" NPT. 7 13/16" 39 9/16" DIRECT FIRED MODULE. AIRFLOW. 20" 19" ∅1 1/2" WATER DRAIN. AIRFLOW. ∅1/2" NPT WATER INLET WATER FILTER REQUIRED PROVIDED BY PLUMBER. FILTER/CONTROL ACCESS DOOR. LPD CELDEK AIRFLOW. 37 3/8" 16 1/4" 20" 31" 20" EQUIPMENT CURB. CURB OUTER WALL. DISCHARGE OPENING. 40 1/8" 36 3/4" 42 1/8"38 1/8" ADJUSTABLE LEG. 172" MIN. 20" MINIMUM STRAIGHT DUCT PER AMCA* FAN #3 A2-D.500-20D - HEATER 1. DIRECT GAS FIRED HEATED MAKE UP AIR UNIT WITH 20" MIXED FLOW DIRECT DRIVE FAN. 2. EVAP COOLER (LPD CELDEK) – W/INTAKE HOOD W/EZ FILTERS. 3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT. 4. DOWN DISCHARGE CONSTRUCTION FOR SIZE 2 DIRECT DRIVE AHUS. 5. GAS PRESSURE GAUGE, 0-35", 2.5" DIAMETER, 1/4" THREAD SIZE. 6. GAS PRESSURE GAUGE, -5 TO +15 INCHES WC., 2.5" DIAMETER, 1/4" THREAD SIZE. 7. BUTTERFLY MOD VALVE OPTION FOR MOD SIZE 2 (1" MOD VALVE). 8. SHIP LOOSE GAS STRAINER. TO BE INSTALLED UPSTREAM OF UNIT CONNECTION. 1" CONNECTION. 9. MOTORIZED BACK DRAFT DAMPER 22.75" X 24" FOR SIZE 2 STANDARD & MODULAR HEATER UNITS W/EXTENDED SHAFT, STANDARD GALVANIZED CONSTRUCTION, 3/4" REAR FLANGE, LOW LEAKAGE, LF120S ACTUATOR INCLUDED. 10. CONTROL PANEL ENCLOSURE HEATER, INCLUDES 100W, 120V HEATER. RECOMMENDED FOR WINTER DESIGN TEMPERATURE LESS THAN 0°F. OPERATES ON PCB CONTROLS IN IBT SINGLE MODULES OR RTU. 11. LAYER CONTROL FOR IBT EVAP. 12. FREEZE PROTECTION DRAIN CONTROL KIT FOR EVAPORATIVE COOLERS. INCLUDES 3-WAY WATER SOLENOID VALVE 8316G064 (SHIPPED LOOSE), PRESSURE SWITCH INSTALLED UPSTREAM OF 2WAY SOLENOID IN UNIT, BRASS TEE, 2 NPT HALF INCH NIPPLES, AND TWO STAGE THERMOSTAT T678A1361. FIELD WIRING REQUIRED BY OTHERS FOR 3-WAY VALVE. FOR BOTH CELDEK AND STANDARD V-BANK TYPE CONFIGURATIONS. 13. FREEZE PROTECTION DRAIN CONTROL KIT FOR EVAPORATIVE COOLERS. INCLUDES 3-WAY WATER SOLENOID VALVE 8316G064 (SHIPPED LOOSE), PRESSURE SWITCH INSTALLED UPSTREAM OF 2WAY SOLENOID IN UNIT, BRASS TEE AND 2 NPT HALF INCH NIPPLES. FIELD WIRING REQUIRED BY OTHERS FOR 3-WAY VALVE. FOR BOTH CELDEK AND STANDARD V-BANK TYPE CONFIGURATIONS. 14. PROFILE PLATE CONFIGURATION FOR SIZE 2 DIRECT FIRED UNIT FOR LOW CFM APPLICATIONS. 15. UNIT MOUNTED VFD FOR USE WITH ECPM03. 16. HINGED DOUBLE WALL INSULATED DOOR ASSEMBLY (BURNER/BLOWER/EVAP SECTION). 17. 2 YEAR PARTS WARRANTY. *NOTE: SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS. A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED DOWNSTREAM OF UNIT DISCHARGE AS OUTLINED IN AMCA PUBLICATION 201. WHEN USING RECTANGULAR DUCTWORK, ELBOWS MUST BE RADIUS THROAT, RADIUS BACK WITH TURNING VANES. FLEXIBLE DUCTWORK AND SQUARE THROAT/SQUARE BACK ELBOWS SHOULD NOT BE USED. ANY TRANSITION AND/OR TURNS IN THE DUCTWORK WILL CAUSE SYSTEM EFFECT. SYSTEM EFFECT WILL DRASTICALLY INCREASE STATIC PRESSURE AND REDUCE AIRFLOW. DO NOT RELY ON UNIT TO SUPPORT DUCT IN ANY WAY. FAILURE TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT. SUGGESTED STRAIGHT DUCT SIZE IS 20" x 20". SUPPLY SIDE HEATER INFORMATION: WINTER TEMPERATURE = -2°F. TEMP. RISE = 81°F. BTUs CALCULATED OFF ACTUAL AIR DENSITY. OUTPUT BTUs AT ALTITUDE OF 0.0 FT. = 316516. INPUT BTUs AT ALTITUDE OF 0.0 FT. = 344039. OUTPUT BTUs AT ALTITUDE OF 4869 FT. = 264651. INPUT BTUs AT ALTITUDE OF 4869 FT. = 287664. L ETS DI R ROOF OPENING 2" SMALLER THAN CURB DIMENSION. 2" 2" 3" FLANGE. 20 GAUGE CONSTRUCTION. STEEL 20" 31" 79" OPTIONS: - FULL BOTTOM CORNERS. CURB. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R C U S 6325918 MASTER DRAWING SLS 7 12/8/2023 Mo ' B e t t a h s - R e x b u r g 1/2" = 1'-0" 46 1 N o r t h 2 n d E a s t , Ut a h O f f i c e 26 9 8 S . R e d w o o d R d . , S u i t e S , W e s t V a l l e y , U T , 8 4 1 1 9 P H O N E : ( 8 0 1 ) 8 7 8 - 3 6 7 7 F A X : 9 1 9 2 2 7 5 9 5 3 E M A I L : r e g 8 7 @ c a p t i v e a i r e . c o m Re x b u r g , I D , 8 3 4 4 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Label Description Location MT-01 Fan Motor [3] Component Identification 23 Installed Options RD - RED BL - BLUE WH - WHITE OR - ORANGE BR - BROWN BK - BLACK PK - PINK PR - PURPLE GY - GRAY GR - GREEN YW - YELLOW WIRE COLOR DENOTES FIELD WIRING DENOTES INTERNAL WIRING NOTES SW-01 Main disconnect switch [3] BK MT-01 GR GR BK SW-01 5 6 3 4 1 2 BK BK L3 L2 V W L1 U VFD CAT 5 TO DCV RJ45RJ45 EOL >=15HP USE RS485 TO MODBUS CONVERTER SW-01 BK GR GR 11 1 JUMPER AND JUMPER 1,4,13A INSTEAD OF 1,11 EXHAUST 3.0HP-208V-3P-9.5FLA VFD PART: ESV222N02YXB571 MOTOR INFO ELECTRICAL INFORMATION MOTOR/CTRL MCA: 11.9A MOTOR/CTRL MOP: 20A P107: P108: P410: P150: P100: P194: P103: P167: P102: 225 01 01 11 98 00 55.3 56.8 0.0 DRAWING NUMBER JOB MODELSHIP DATE Exhaust Fan Wiring EXH6325918-1 6325918 - Mo' Bettahs - Rexburg 12/8/2023 DU180HFA 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Label Description Location MT-01 Fan Motor [3] SW-01 Main disconnect switch [3] Component Identification 23 Installed Options RD - RED BL - BLUE WH - WHITE OR - ORANGE BR - BROWN BK - BLACK PK - PINK PR - PURPLE GY - GRAY GR - GREEN YW - YELLOW WIRE COLOR DENOTES FIELD WIRING DENOTES INTERNAL WIRING NOTES SW-01 BK MT-01 RD GR GR RD BK 3 4 1 2 WH *22 AWG WHITE MOTOR *22 AWG ROTATION WIRE. CONNECT TO POWER MOTOR CONTROL RD YW PWM FROM ECPMO3 RD BK LEG BLACK WIRE TO REVERSE ROTATION GR EXHAUST 1.0HP-208V-1P-6.9FLA MOTOR INFO ELECTRICAL INFORMATION MOTOR/CTRL MCA: 8.7A MOTOR/CTRL MOP: 15A DRAWING NUMBER JOB MODELSHIP DATE Exhaust Fan Wiring EXH6325918-2 6325918 - Mo' Bettahs - Rexburg 12/8/2023 DU85HFA A B C D E F G H I 1 2 3 4 5 6 7 8 9 10 COMPONENT LIST LABEL DESCRIPTION J1 J10 120V J30 120V J29 120V J9 120V 10 1 J15 10 1 J35 123456789 101112131415161718 J7 1234567 891011121314 J13 1234567 891011121314 J18 SW-01 BK 1 2 3 4 TH E R M I S T O R S TH E R M I S T O R S 4 5 A 3 2 7 6 S2 S1 RD OR WH GY BK BR YW GR BK FR-01 FSC-01 TR-02 SPARK PLUG N BK WH J2 J3 J4 J5 J6 123456789 101112131415161718 123456789 101112131415161718 J31 123456789 101112131415161718 J36 123456789 101112131415161718 J32 VA-02 VA-01 BL BR YW LEGEND FIELD WIRING FACTORY WIRING BK- BLACK BL- BLUE BR- BROWN OR- ORANGE WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/GN STRIPE WH/BL- WH/BL STRIPE YW- YELLOW GY- GREY PR- PURPLE RD- RED GR- GREEN P FL W D OR RD BK BR BK DM BK IEL OR WH RD BL MT-01 GR FIRE I/P TRIPS UPON 120VAC BK HE-01 WH F BK N 2x H 2x 8 AI-4DI-2 J28 1 AI-3AI-2 J14 1 8 AI-1DI-1 J12 1 8 C R BA S / S T A T G Y W J16 8 1 J11 8 1 NC C SW-07 RD H VA-07 BK WH N TP1(FSC-1) TP 2 ( F S C - 1 ) H CB-01 N SUPPLY RD BL MT-05 120VAC O/P 120VAC I/P SN-04 SN-03 SN-01 CNC SW-08 OR VA-08BK WH J33 VFD T1 T2 T3 RJ45 RJ45 EOL >=15HP USE RS485 TO MODBUS CONVERTER L1 L2 L3 CAT 5 TO ECPM03 BK BK 5 6 (CONVERTER MOUNTED IN MUA) MODBUS J38 3 1 BP 120V BC HMI J2 208V H N BP RD BC BL BK WH 24V (40VA) 120V H 2 ON 1 3 4 MUA Board 2 ON S2 1 1 ON PROG BP S1*S3* H N NOTES * = S4 and S6 may be needed for NFBUP-S. J2 SPACE HMI BP TR - 0 1 LOCAL HB TR-05 GR BK RD BL WH T1/L1 T2/L2 NOT REQ IF SPACE SENSOR IS WIRED ON 1 2 3 4 5 6 7 8 0-10VDC Output RH SENSOR BL-24VAC GY-INTLK SN-03 OR IEL N A1A2 RE-DV IEL/DEL RD YW and IL1B in DCV Wire to IL1A NOC RD YW RE-DV-1 D7 D3 GR AL HMI J3 LOCAL BK WH BK RD TR-03 120 24 VA-05 WH BK WH HN MOD-1 BK 123456789 101112131415161718 J8 Y(3)U(5) C(1)+(2) SUPPLY 5.0HP-208V-3P-15.0FLA VFD PART: ESV402N02TXB571 MOTOR INFO ELECTRICAL INFORMATION MOTOR/CTRL CIRCUIT MCA: 20.9A MOTOR/CTRL CIRCUIT MOP: 35A P107: P108: P410: P150: P100: P194: P103: P167: P102: 225 01 01 21 90 00 75.0 76.4 0.0 DWG NO JOB NO DATE DRAWN BY JOB NAME DESCRIPTION OF OPERATION TYPE DRAWING TITLE MUA BOARD (DETAILS TO FOLLOW) 6325918 Mo' Bettahs - R... FACTORY AUTO 12/8/2023 HW6325918-3 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 HE-01 CABINET_HEATER EVO/ECM-ACU+S1.1-MPFR-01 FIREYE_FLAME_SAFETYFSC-01 SUPPLY_MOTORMT-01 CIRCUIT_BREAKERCB-01 MT-05 INTAKE_DAMPER_MTR DISCH/HIGH_LIMIT OUTDOOR INTAKE SW-01 DISCONNECT_SWITCH IGNITION_TRANSFMRTR-02 VA-07 EVAP_3_WAY_VALVE MAIN_GAS_VALVEVA-02 CTRL_TRANSFMRTR-01 TEMP_SENSORSN-XX EVAP_PRESS_SWITCHSW-07 EVAP_FLOAT_SWITCHSW-08 BOARD_POWER_TRFMRTR-05 VA-08 EVAP_VALVE DCV_RELAYRE-DV B5/D1 B5 E5 B5 C5 I4/I5/I6/I7 B3 F7 C6 B9 A3 C4 B3 E3 B8 B8 B4 F7VA-01 PILOT_GAS_VALVE OUTDOOR VA-02 MAIN_GAS_VALVE VA-01 PILOT_GAS_VALVE C7 C7 VA-05 MOD_GAS_VALVE E7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 WIRE COLOR BK - BLACK BL - BLUE BR - BROWN OR - ORANGE RD - RED WH - WHITE YW - YELLOW GR - GREEN NOTES DENOTES FIELD WIRING DENOTES INTERNAL WIRING GY - GRAY Label Description Location Component Identification 23 PR - PURPLE PK - PINK Installed Options Pressure SwitchSW-07 [2][8] To building drain Field Wired and Piped From building water supply Roof line N POINT-TO-POINT SUMMARY OF DRAIN CONNECTION N FL P W D H EVAP COOLER TERMINALS EQUIVALENT TERMINALS LOCATED IN IBT NC C SW-07 C NC SW-08 VA-08 VA-07 YW RD OR BK BK WH OR WH H P FL W D Float SwitchSW-08 [2][9] 3 Way Drain ValveVA-07 [4][15] Water SolenoidVA-08 [3][10] Freeze Protection DRAWING NUMBER JOB MODEL SHIP DATE Evaporative Cooler Wiring IBTEC6325918-3 6325918 - Mo' Bettahs - Rexburg 12/8/2023 A2-D.500-20D Power Connection 208/460/600 V 3 PH. Gal-flex conduit (in unit) BK Disconnect Switch BK Disconnect Switch 120 V 1 PH.240 V 1 PH. Customer supplied wiring Factory wiring Disconnect Switch Installed Options RD - RED BL - BLUE WH - WHITE BK - BLACK OR - ORANGE BR - BROWN PK - PINK PR - PURPLE GY - GRAY GR - GREEN YW - YELLOW WIRE COLOR NOTES BK GR Gal-flex conduit (in unit) BK Customer supplied wiring Factory wiring RD GR Gal-flex conduit (in unit) BK Customer supplied wiring WH Factory wiring GR WHRD STANDING POWER RD & WH Wire (115V, 1 PHASE) See above details. Cat 5 to DCV FIELD WIRED CONTACTS WHEN USED WITH PREWIRE WIRE TO SFC1/SFO1 TO J16-5 & J16-6 ON MUA TO D3 & D7 Field Wired Switch SFC1 SFO1 BL GY D3 D7 DAMPER INTERLOCK WIRE TO IL1A & IL1B YW RD DRAWING NUMBER JOB MODEL SHIP DATE Installation Wiring RP6325918-3 6325918 - Mo' Bettahs - Rexburg 12/8/2023 A2-D.500-20D HMI SCHEDULE UNIT NUMBER HMI #HMI LOCATION TEMP AVERAGING MODBUS ADDRESS FAN #3 HMI #1 - UNIT HMI # 1 MOUNTED IN UNIT NOT AVERAGED 55 SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R C U S 6325918 MASTER DRAWING SLS 8 12/8/2023 Mo ' B e t t a h s - R e x b u r g 3/4" = 1'-0" 46 1 N o r t h 2 n d E a s t , Ut a h O f f i c e 26 9 8 S . R e d w o o d R d . , S u i t e S , W e s t V a l l e y , U T , 8 4 1 1 9 P H O N E : ( 8 0 1 ) 8 7 8 - 3 6 7 7 F A X : 9 1 9 2 2 7 5 9 5 3 E M A I L : r e g 8 7 @ c a p t i v e a i r e . c o m Re x b u r g , I D , 8 3 4 4 0 ELECTRICAL PACKAGE - JOB#6325918 1 DCV-2111 UTILITY CABINET RIGHT UTILITY CABINET RIGHT HOOD # 2 1 LIGHT 1 FAN SMART CONTROLS DCV EXHAUST EXHAUST SUPPLY 3 1 3 3.000 1.000 5.000 208 208 208 9.5 6.9 15.0 NO TAG PACKAGE #LOCATION SWITCHES LOCATION QUANTITY OPTION FANS CONTROLLED TYPE ɸ HP VOLT FLA DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 6325918 Mo' Bettahs - Rexburg DCV-2111 12/8/2023 INSTALL ECP #1-1 Demand Control Ventilation, w/ control for 2 Exhaust Fans, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fans modulate based on duct temperature. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. Room temperature sensor shipped loose for field installation.Verify distance between VFD and Motor; additional cost could apply if distance exceeds 50 feet. BREAKER PANEL TO PRIMARY CONTROL PANEL Responsibility: Electrician BREAKER PANEL PRIMARY CONTROL PANEL BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED BREAKER 1PH CONTROL POWER. DO NOT WIRE TO GFCI OR SHUNT TRIP BREAKER. Hot Neutral H1 N1 120 V 15 A Ground GND 1ST HOOD LIGHT BREAKER SHARED W/ CONTROL POWER. SWITCH #1 BREAKER PANEL TO FANS Responsibility: Electrician BREAKER PANEL FANS POWER TO REMOTE WIRE DIRECTLY TO FAN DISCONNECT BREAKER 3PH MCA: MOCP: VFD LINE LINE LINE EXH-1 Ground 208V 11.9A 20A SM-1 POWER TO REMOTE WIRE DIRECTLY TO FAN DISCONNECT BREAKER 3PH MCA: MOCP: VFD LINE LINE LINE SUP-3 Ground 208V 18.8A 30A SM-2 BREAKER 1PH MCA: MOCP: POWER TO ECM FANS LINE LINE 208V 8.6A EXH-2 Ground 15A CONTROL PANEL TO FANS Responsibility: Electrician PRIMARY PANEL FANS REMOVE EOL FROM THE LAST COM LINK MOUNTED VFD MODBUS SLAVE CONNECTED TO J3 NETWORK AND WIRE IN THE CAT-5 CABLE. PLACE EOL IN EMPTY RJ-45. CAT-5 CONNECTION. EOL120A TO J2 1 2 EXH-1 MB EX1 SM-1MB EX1 SHIELDED TWISTED PAIR PWM SPEED SIGNAL CONTROL PANEL TO ECM OUTDOOR RATED FEED STP THROUGH INNER COOLING TUBE. ALLOW FOR ENOUGH SLACK ON STP FOR PROPER HINGING. (EXHAUST ONLY) NOTE: PWM SIGNAL IS POLARITY SENSITIVE. NIDEC MOTOR TELCO MOTOR BK TO GR BK TO YW RD TO RD ZIEHL MOTOR BK TO BK P1A P1B EXH-2 ECM-01 FAN: 02 RED(+) BLACK(-) ECM-01 RED(+) BLACK(-) REMOVE EOL FROM THE LAST MODBUS SLAVE CONNECTED TO J3 NETWORK AND WIRE IN THE CAT-5 CABLE. PLACE EOL IN EMPTY RJ-45. CAT-5 CONNECTION. EOL120ACOM LINK MOUNTED VFD TO J3 1 2 SM-2 SUP-3 ECPM03 ECPM03 FAN START SIGNAL TO MUA BOARD *WIRE TO UNIT INTERLOCK SFO1 SFC1 24VAC 24VAC 24V UI* SUP-3 MAKE UP AIR PROVING INTERLOCK DAMPER LOW VOLTAGE CONNECTION FOR DAMPER INTERLOCK. WIRE MULTIPLE SUPPLY ON THE SAME ZONE IN SERIES. SHOULD MUA ZONE 1 TERMINAL NAMES DO NOT APPLY IF MUA BY OTHERS ON PCB REMOVE JUMPER HAVE CONTINUITY WHEN DAMPER IS PROVEN OPEN. NOT REQUIRED FOR ALL UNITS. SEE MAKE-UP AIR SCHEMATIC. IL1A IL1B D3 D7 CONTROL PANEL TO ACCESSORY ITEMS Responsibility: Electrician CONTROL PANEL COMPONENT ALL SWITCHES FACTORY WIRED CAT-5 CONNECTION CONTROL PANEL SWITCHES TO J4 CONTROL PANEL HOOD LIGHTS TO 1400 W MAX WIRE TO J-BOX ON TOP OF HOOD B1 W1 GND BLACK WHITE GREEN HOOD LIGHTS 1 WIRE TO CONTROL BOARD. INSTALL SENSOR IN ROOM AWAY FROM HEAT SOURCES. DO NOT INSTALL SENSOR CONTROL PANEL ROOM TEMP TO SENSOR ON THE CEILING GRID, SEE MANUAL. GROUPS: T1A T1B ROOM TEMP FACTORY WIRED TEMPERATURE SENSOR. MOUNTED IN HOOD CAPTURE CONTROL PANEL CAPTURE VOLUME TO SENSOR VOLUME. T2A T2B HOOD 2 CAPTURE 1 WIRE TO CONTROL BOARD. SENSOR MOUNTED IN EXHAUST DUCT CONTROL PANEL DUCT SENSOR TO T3A T3B HOOD 1 RISER 1 CONTROL PANEL GAS VALVE TO 120V ONLY ONLY ENERGIZED THROUGH LCD HMI WHEN FIRE SYSTEM ARMED. GAS N1 HOT TO GAS VALVE NEUTRAL GAS SOLENOID THE FOLLOWING CONNECTIONS MAY OR MAY NOT BE REQUIRED BASED ON JOBSITE SPECIFICATIONS CONTROL PANEL EXTERNAL SIGNAL FOR SHUNT TRIP ST TERMINAL IS ENERGIZED IN FIRE CONDITION. CONTROL PANEL EXTERNAL SIGNAL FOR CONTACTOR COIL KS TERMINAL IS DE-ENERGIZED IN FIRE CONDITION. ST N1 NEUTRAL FROM SHUNT COIL HOT TO SHUNT COIL SHUNT COIL KS N1 NEUTRAL_TO_CONTACTOR_COIL HOT_TO_CONTACTOR_COIL CONTACTOR_COIL SPARE CONTACTS WILL MAKE CONTROL PANEL ON/OFF WITH DRY CONTACT SUPPLY FAN COMMON TO NORMALLY OPEN WHEN SUPPLY FAN IS ON. GROUP 1 SFC1 SFO1 COMMON NORMALLY OPEN SFC2 SFO2 COMMON NORMALLY OPEN WIRE TO ECPM03 TERMINALS. CONFIGURABLE OUTPUT. DCV SPEED (TOTAL) 0-10V OUTPUT ON PCB SEE ECPM03 OWNERS MANUAL. TO BMS + - VO+ VO- WIRE TO VFD TERMINAL STRIP. PROPORTIONAL TO FREQUENCY. VFD ANALOG (EACH VFD) 0-10V OUTPUT IN VFD SEE VFD OWNERS MANUAL. TO BMS + - 30 2 CONTROL PANEL EXTERNAL TO SWITCH SIGNAL SWITCH THROUGH BMS WILL ACTIVATE ZONE1 FANS AND LIGHTS H1 IO1 BMS SWITCH C NO CONTROL PANEL GAS VALVE TO 24V DC ONLY ONLY ENERGIZED THROUGH LCD HMI WHEN FIRE SYSTEM ARMED. (NOT NEEDED IF USING 120V GAS VALVE). LGV N1D POSITIVE TO GAS VALVE NEGATIVE GAS SOLENOID DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 6325918 Mo' Bettahs - Rexburg DCV-2111 12/8/2023 INSTALL ECP #1-2 Demand Control Ventilation, w/ control for 2 Exhaust Fans, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fans modulate based on duct temperature. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. Room temperature sensor shipped loose for field installation.Verify distance between VFD and Motor; additional cost could apply if distance exceeds 50 feet. CONTROL PANEL TO FIRE SYSTEM Responsibility: ALARM CONTRACTOR CONTROL PANEL COMPONENT CONTROL PANEL BUILDING SIGNAL FOR FIRE ALARM PANEL AL1 AL2 J9 BUILDING ALARM PANEL FIRE INPUT WIRE DIRECTLY TO CORE CIRCUIT BOARD. AL1 WILL MAKE AL2 IN FIRE CONDITION. CONTROL PANEL BUILDING SIGNAL FOR TROUBLE TROUBLE RELAY CONTACTS WILL MAKE TBC TO TBL IN TROUBLE CONDITION. BUILDING ALARM PANEL ALARM TBC TBL COMMON NORMALLY CLOSED CONTROL PANEL TO FIRE SYSTEM Responsibility: CERTIFIED INSTALLER CONTROL PANEL COMPONENT FIRE STAT SUPERVISED LOOP May be mixed factory and field wiring. See Installation Schematic. Multiple fire sensors possible. HIGH TEMP WIRE (842 F), PN: SLPCON-xFT required for all Supervised Loop wiring in contact with a hood. All other wiring shall be PN: 6320UL, Belden or similar. 21 22 23 24 FS-01 BK WH Fire Stat FS-02 BK WH Fire Stat CONTROL PANEL MOUNTED FIRE TO DUCT DETECTION STAT(S) FIRE STATS CONTROL PANEL SYSTEM PULL TO FIRE STATION MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM LOOP. Multiple manual actuation possible. Multiple manual actuation possible. A Plug jumper with wires from pin1 to pin4 and from pin2 to pin3 is mounted on J10, remove the jumpers and wire in the supervised actuation loop. Microswitch MS-01 is optional for fire system interlock. Auxiliary Interlock (AUX-01): Wire AU1 / AU2 of adjacent Master FS panel(s) in each manual activation loop for simultaneous activation. See Fire system drawings for more information. 101 102 103 104 AUX-01 AU1 AU2 PULL STATION MS-01 C NO Micro SW MAD-01 C NO Manual Actuation Device Adjacent FS Panel CAT-5 CONNECTION CONTROL PANEL MASTER FS TO BOARD. PLACE END OF LINE PLUG EOL120A IN EMPTY JACK. PN: EOL120A CORE PCB ADDITIONAL DEVICES MAY BE INLINE. ECPM03 UNLESS VFD, PCU, OR OTHER COMPONENT IN SERIES. J3 J5 J6 CONTROL PANEL MASTER FS TO PANEL WIRE TO LIKE TERMINALS IN ALL CORE PANELS THAT MUST ACTIVATE TOGETHER. SET MASTER & SLAVE DIP SWITCHES PER FIRE SYSTEM SHIELDED TWISTED PAIR INTERLOCK NETWORK MASTER CORE MANUAL. CA CB CC BLACK RED SHIELD CA CB CC TANK PROTECTION ELECTRICAL DETAIL 02/10/2021 Rev. 2 ELECTRICIAN: 1. WIRE MAIN CONTROL PANEL PER INCLUDED SCHEMATIC 2. WIRE ALL FANS PER INCLUDED SCHEMATIC 3. WIRE SHUNT TRIP BREAKER (OPTIONAL) 4. WIRE UDS APPLIANCE KILL SWITCH, IF EQUIPPED (OPTIONAL) 5. WIRE GAS VALVE NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS EXHAUST HOOD 36 INCHES CLEARANCE REQUIRED IN FRONT OF ALL UTILITY CABINET DOORS THE PANEL SHALL ALSO BE LOCATED IN AN ACCESSIBLE AREA WHERE THE AUDIBLE AND VISUAL ALARMS CAN BE HEARD AND SEEN GASELECTRIC ELECTRICAL CONTRACTOR REQUIREMENT ITEM CONNECTION IN PANEL CONNECTION IN DEVICE VOLTAGE AMPERAGE COMMENTS SHUNT TRIP BREAKER (OPTIONAL)ST & N1 BREAKER COIL (A1 & A2) 120 VAC < 4 AMPS ST TO A1 ON SHUNT BREAKER COIL, AND NEUTRAL TO A2 ON SHUNT TRIP BREAKER COIL CONTROL PANEL POWER H1 & N1 + GROUND CIRCUIT BREAKER 120 VAC 15 AMPS CONTROL PANEL POWER MUST NOT BE RUN THROUGH SHUNT TRIP BREAKER UDS APPLIANCE KILL SWITCH (OPTIONAL)KTS & N1 KTS & N1 120 VAC < 4 AMPS KILL SWITCH TERMINALS MUST BE IN SERIES WITH OTHER KILL SWITCHES REMOTE 120VAC ANSUL AUTOMAN (OPTIONAL)AU1, AU2 SOLENOID 120 VAC < 6 AMPS 120V TO AU1, AU2 TO ANSUL ELECTRIC AUTOMAN, ANSUL SOLENOID TO NEUTRAL GAS VALVE LGV & N1D (IF 24 VDC) GAS & N1 (IF 120 VAC) RED/RED/GREEN 24 VDC OR 120 VAC < 1.0 AMPS IF 24 VDC - 2 WIRES & GROUND, N1D TO RED, LGV TO RED, AND GREEN TO GROUND IF 120 VAC - 2 WIRES & GROUND GAS TO RED, N1 TO RED, AND GREEN TO GROUND SHUNT TRIP BREAKER (OPTIONAL) -2 WIRES, 120VAC -ST TO A1 ON SHUNT BREAKER -NEUTRAL TO A2 ON SHUNT TRIP BREAKER POWER TO ELECTRIC APPLIANCE CONTROL PANEL POWER -2 WIRES & GROUND -120 VAC, 15 AMP SERVICE -WIRE TO H1 AND N1, GROUND -POWER MUST NOT ORIGINATE FROM SHUNT TRIP BREAKER GAS VALVE POWER -2 WIRES & GROUND -24 VDC WIRE TO LGV & N1D -120 VAC WIRE TO GAS &N1 GAS VALVE -STRAINER MUST BE INSTALLED UPSTREAM OF VALVE COOKING APPLIANCE(S) DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 6325918 Mo' Bettahs - Rexburg DCV-2111 12/8/2023 INSTALL ECP #1-3 Fire System #1 TANK FS - 4.0/4.0/4.0. FS-1: MASTER TANK PROTECTION LOW-VOLTAGE DETAIL 02/10/2021 Rev. 2 ALARM CONTRACTOR: 1. WIRE MANUAL ACTUATION DEVICE(S), REMOTE FIRESTAT(S), CORE INTERLOCK(S), FIRE SENSOR(S) AND FIRE ALARM CONTACTS 2. COMPLETE FINAL HOOKUP OF SYSTEM 3. VERIFY FINAL FIRE SYSTEM TEST ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES 36 INCHES CLEARANCE REQUIRED IN FRONT OF ALL UTILITY CABINET DOORS THE PANEL SHALL ALSO BE LOCATED IN AN ACCESSIBLE AREA WHERE THE AUDIBLE AND VISUAL ALARMS CAN BE HEARD AND SEEN EXHAUST HOOD ELECTRIC GAS NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS ALARM CONTRACTOR REQUIREMENT ITEM CONNECTION IN PANEL CONNECTION ON DEVICE VOLTAGE AMPERAGE COMMENTS MANUAL ACTUATION DEVICE(S) 101 AND 104 102 AND 103 1 & 2 24 VDC < 1.0 AMPS WIRE MANUAL ACTUATION DEVICE TERMINAL 1 BETWEEN CORE PANEL TERMINALS 102 AND 103 WIRE MANUAL ACTUATION DEVICE TERMINAL 2 BETWEEN CORE PANEL TERMINALS 101 AND 104 JUMPER 101 TO 104 AND 102 TO 103 IF NO MANUAL ACTUATION DEVICE IS INSTALLED MANUAL ACTUATION DEVICE COVER N/A N/A N/A N/A MANUAL ACTUATION DEVICE COVER MUST BE INSTALLED IF SURFACE MOUNTED, USE COVER EXTENSION STI-6531B REMOTE FIRESTAT SENSOR(S) 21 AND 24 22 AND 23 BLACK AND WHITE 24 VDC < 1.0 AMPS WIRE FIRE SENSOR WHITE WIRES BETWEEN HOOD CORE PANEL TERMINALS 22 AND 23 WIRE FIRE SENSOR BLACK WIRE BETWEEN HOOD CORE PANEL TERMINALS 21 AND 24 HIGH TEMP (842°F) #CW04427 (WHT) & #CW04427B (BLK)WIRE OR SIMILAR ONLY IF RAN OVER TOP OF HOOD; OTHERWISE BELDEN #6320UL OR SIMILAR PLENUM RATED WIRE; SEE FIGURE 1 FIRE ALARM CONTACT AL1, AL2 VARIES 50V MAX (AC/DC) UP TO 1 AMP FIRE ALARM RELAY CONTACTS FOR BUILDING FIRE ALARM LOCATED IN THE CORE ELECTRICAL CONTROL PANEL CORE INTERLOCK(S)ILA, ILB, ILC ILA, ILB, ILC RS-485 COMMUNICATIONS SIGNAL CORE SYSTEM (1) ILA, TO CORE SYSTEM (2) ILA. CORE SYSTEM (1) ILB, TO CORE SYSTEM (2) ILB. CORE SYSTEM (1) ILC, TO CORE SYSTEM (2) ILC. USE BELDEN# 88760 OR SIMILAR WIRE TROUBLE CONTACT TBC, TBL, TOK VARIES MAX 120 VAC UP TO 6 AMPS WIRE TO TBL & TBC NORMALLY OPEN CONTACT, CLOSES IN TROUBLE CONDITION CORE COMMUNICATIONS CABLE RJ-45 Jack INTERNET CONNECTION SIGNAL <1.0 AMPS TYPICAL CONNECTION CAT5 CABLE TO LOCAL AREA NETWORK VIA ETHERNET SWITCH OR WIRELESS ROUTER WITH VALID INTERNET CONNECTION 42 TO 48 INCHES ABOVE FLOOR LEVEL TO CENTER OF PUSH STATION MANUAL ACTUATION DEVICE 10 TO 20 FEET FROM HOOD LOCATED NEAR POINT OF EGRESS FROM HOOD MANUAL ACTUATION DEVICE WIRES -4 WIRES, 24VDC WIRE (TERMINAL 1) BETWEEN 102 AND 103 -WIRE (TERMINAL 2) BETWEEN 101 AND 104 -ADDITIONAL PULL STATIONS WIRED IN SUPERVISED LOOP -USE BELDEN #6320UL OR SIMILAR WIRE -SEE FIGURE 2 MANUAL ACTUATION DEVICE PART #STI-SS2431 PROTECTIVE COVER MUST BE INSTALLED SUPERVISED LOOP -4 WIRES, 24VDC CONNECT BLACK WIRES BETWEEN 21 AND 24 IN PANEL, CONNECT WHITE (OR RED) WIRES BETWEEN 22 AND 23 IN PANEL -ADDITIONAL FIRESTATS, WIRED IN SUPERVISED LOOP -USE HIGH TEMP (842°F) #CW04427 (WHT) & #CW04227B (BLK)WIRE ONLY IF RAN OVER TOP OF HOOD; OTHERWISE BELDEN #6320UL OR SIMILAR PLENUM RATED WIRE -SEE FIGURE 1 CORE COMMUNICATIONS CABLE -CAT5 CABLE MUST BE INSTALLED TO A LOCAL AREA NETWORK WITH VALID INTERNET ACCESS VIA ETHERNET SWITCH OR WIRELESS ROUTER CORE INTERLOCK -2 WIRES + SHIELD -USE BELDEN#88760 OR SIMILAR WIRE -SEE FIGURE 3 FIRE ALARM PANEL FIRE ALARM CONTACT -2 WIRES WIRED TO NORMALLY OPEN CONTACTS (CLOSES IN FIRE CONDITION) -CORE CONTROL PANEL AL1 AND AL2 -SEE FIGURE 2 TROUBLE CONTACT -2 WIRES TO NORMALLY OPEN CONTACTS (CLOSE IN TROUBLE CONDITION) -CORE PANEL TERMINALS TBL AND TBC -SEE FIGURE 4 COOKING APPLIANCE(S) DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 6325918 Mo' Bettahs - Rexburg DCV-2111 12/8/2023 INSTALL ECP #1-4 Fire System #1 TANK FS - 4.0/4.0/4.0. FS-1: MASTER SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R C U S 6325918 MASTER DRAWING SLS 9 12/8/2023 Mo ' B e t t a h s - R e x b u r g 3/4" = 1'-0" 46 1 N o r t h 2 n d E a s t , Ut a h O f f i c e 26 9 8 S . R e d w o o d R d . , S u i t e S , W e s t V a l l e y , U T , 8 4 1 1 9 P H O N E : ( 8 0 1 ) 8 7 8 - 3 6 7 7 F A X : 9 1 9 2 2 7 5 9 5 3 E M A I L : r e g 8 7 @ c a p t i v e a i r e . c o m Re x b u r g , I D , 8 3 4 4 0 TANK PROTECTION LOW-VOLTAGE FIGURES 02/10/2021 Rev. 17 AL1 AL2 END OF LINE DEVICE WIRING CONNECTIONS FOR FIRE ALARM CONTACT FIGURE 2 CORE CONTROL PANEL FIRE ALARM CONTACT ALARM INPUT BUILDING FIRE ALARM SHIELDED TWISTED PAIR ILA ILC ILB ILA BK ILB RD BK RD WIRING CONNECTIONS FOR CORE INTERLOCK FIGURE 3 ILC ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES SUPERVISION SWITCH 1 2 C BUILDING FIRE ALARM TROUBLE INPUT CORE CONTROL PANEL TROUBLE CONTACT NO C NC 1 C 2 SUPERVISION SWITCH SUPERVISION SWITCH END OF LINE DEVICE TBC TBLTOK WIRING CONNECTIONS FOR TROUBLE CONTACT FIGURE 4 BK-C BK-C 21 22 23 24 J2-1 J2-2 J2-4 J2-3 21 BK-C 101 102 103 104 J10-1 J10-2 J10-4 J10-3 21 BK-C WIRING CONNECTIONS FOR FIRESTAT LOOP FIGURE 1 WIRING CONNECTIONS FOR MANUAL ACTUATION LOOP FIGURE 1A BREAK WIRE BEFORE INSERTING INTO TERMINALS FIRE STAT-2 FIRE STAT-1 NO-WH (OR RD) NO-WH (OR RD) BREAK WIRE BEFORE INSERTING INTO TERMINALS NO-WH (OR RD) MANUAL ACTUATION DEVICE NO-WH (OR RD) MANUAL ACTUATION DEVICE MICROSWITCH/ NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS USE BELDEN #6320UL OR SIMILAR WIRE DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 6325918 Mo' Bettahs - Rexburg DCV-2111 12/8/2023 INSTALL ECP #1-5 Fire System #1 TANK FS - 4.0/4.0/4.0. FS-1: MASTER WH BK A B C D E F G H I 1 2 3 4 5 6 7 8 9 10 PANEL LID COMPONENT LIST LABEL DESCRIPTION PN: ST-X varies Starter PN: OL-X varies Overload PN: C-X varies Contactor PN: TS-x A/CP-PO-T4"-EXPL Duct Thermostat 120 VAC RELAY NO COM COIL NC 34 6 5 8 2 7 1 RA-x 24 VDC RELAY RD-x NO COM COIL NC 34 6 5 8 2 7 1 PN: PS-1 MDP18-24A-1C Power Sup. 24VDC BK PN: RA-x 34.110.0184.0 120V Relay DPDT WH PN: RA-x 34.110.0184.0 120V Relay DPDT GR UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG. N1 H1 DC - GN D DC + 8H1 7PCU 6ST 5KS 4KTS 3GAS 2AR1 1N1 120VJ9 5OV1 4SF1 3EF1 2B1 1IO1 120VJ7 AR1 H1 2x N1 2x B1 EF1 SF1 BK IO1 BK BK BK JUMPER W1 BK 14AWG BK 64 RD-1 BL PR DC+RO1 PN: RD-x 34.110.0188.0 24VDC Light Relay BK WH SF1 7 8RA-2 8 7RD-1 24V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 J6 N1 ON/OFF WITH SUP N1 RO 1 NH FAN PANEL COOLING DRY CONTACTS (SHOWN DE-ENERGIZED) HOOD LIGHTS J3 ECPM03/DAISY CHAIN AR1 H1 JUMPER FIRE SYSTEM BK BK BK GAS KS ST NOTE: Configure ECPM03 for CORE ECPM03 J10 IL 1 A IL 1 B JUMPER MAKE UP AIR INTERLOCK. NOTE: All items on ECPM03 J3 line to be daisy chained from one component to the next, with EOL120A at end of line. Place PN: EOL120A in empty RJ45 port. J3 ECPM03 or Previous EOL J5 MASTER CORE C RA-2-1 NO SFC1 SFO1 14 AWG YW C RA-2-2 NO SFC2 SFO2 14 AWG YW FACTORY WIRING SCHEMATIC CIRCUIT BOARDS ECPM03 SC-20 x 18 x 8.62 BOX CONTROL INPUT 120V H1=LINE, N1=NEUTRAL, 15A BREAKER. DO NOT CONNECT TO SHUNT TRIP BREAKER. SEE INSTALLATION SCHEMATIC FOR ADDITIONAL REQ. NOTE: IF VFD HAS 1PH 240V INPUT, USE L1 & L2 ONLY. IF VFD HAS 1PH 120V INPUT, USE L1 & N ONLY. LEGEND FIELD WIRING FACTORY WIRING BK- BLACK BL- BLUE BR- BROWN OR- ORANGE WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/GN STRIPE WH/BL- WH/BL STRIPE RD- RED PR- PURPLE GY- GREY YW- YELLOW WH / B L BL H1N1 DC - DC + LN -+ PS-01 AC 24V GN D DC KSKS BK KS BK BK GAS ST P1 A ( + ) P1 B ( - ) 58.2% 72.8% BK EF1 PR WH GR / Y W WH / B L BL J4 A MB EX1 BC A B C J1 J2 J3 J4 J5 J5 J5 ECPM03 NOTE: MODBUS EX BOARDS USED FOR REMOTE MOUNTED VFD. REFER TO INSTALL SCHEMATIC FOR CONNECTIONS. PN: MB EX1 MODBUS-EX Modbus Expansion NH FAN SECONDARY PANEL COOLING IF NECESSARY EF1 WHBK JUMPER ECPM03 J10 IL 2 A IL 2 B TERMINAL GAS USED FOR 120V POWERED GAS VALVES ONLY DWG NO JOB NO DATE DRAWN BY JOB NAME DESCRIPTION OF OPERATION TYPE DRAWING TITLE 6325918 Mo' Bettahs - Re... FACTORY DCV-2111 12/8/2023 ECP #1-6 Demand Control Ventilation, w/ control for 2 Exhaust Fans, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fans modulate based on duct temperature. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. Room temperature sensor shipped loose for field installation.Verify distance between VFD and Motor; additional cost could apply if distance exceeds 50 feet. A B C D E F G H I 1 2 3 4 5 6 7 8 9 10 MOTOR POWER CIRCUITS. SEE INSTALLATION COMPONENT LIST LABEL DESCRIPTION PN: ST-X varies Starter 120 VAC RELAY NO COM COIL NC 34 6 5 8 2 7 1 RA-x 24 VDC RELAY RD-x NO COM COIL NC 34 6 5 8 2 7 1 FACTORY WIRING SCHEMATIC CIRCUIT BOARDS ECPM03 DCV Rev. 2.10.00 HMI Rev. 2.10.00 SC-20 x 18 x 8.62 BOX DIAGRAM FOR FIELD WIRING REQUIREMENTS. PN: C-X varies Contactor PN: SM-X varies VFD LEGEND FIELD WIRING FACTORY WIRING BK- BLACK BL- BLUE BR- BROWN OR- ORANGE WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/GN STRIPE WH/BL- WH/BL STRIPE RD- RED PR- PURPLE GY- GREY YW- YELLOW PN: LR-X varies Line/Load Reactor DWG NO JOB NO DATE DRAWN BY JOB NAME DESCRIPTION OF OPERATION TYPE DRAWING TITLE 6325918 Mo' Bettahs - Re... FACTORY DCV-2111 12/8/2023 ECP #1-7 Demand Control Ventilation, w/ control for 2 Exhaust Fans, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fans modulate based on duct temperature. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. Room temperature sensor shipped loose for field installation.Verify distance between VFD and Motor; additional cost could apply if distance exceeds 50 feet. BK BK BK BK BK BK BK BK BK BK BK BK U/T1 V/T2 W/T3 L1 L2 L3/N GR GR GND TO MOTOR VFD: HP: MTR: FLA: P107: P108: P410: P150: P100: P194: P101: P131: P167: P103: P102: 3 PH 20 A 208 V SM-1 ESV222N02YXB571 225 01 01 11 98 00 9.5 3.000 EXH-1 N/A N/A 56.8 55.3 0.0 GND 14 AWG Mounted in Fan BK BK BK BK BK BK BK BK BK BK BK BK U/T1 V/T2 W/T3 L1 L2 L3/N GR GR GND TO MOTOR VFD: HP: MTR: FLA: P107: P108: P410: P150: P100: P194: P101: P131: P167: P103: P102: 3 PH 30 A 208 V SM-2 ESV402N02TXB571 225 01 01 21 90 00 15.0 5.000 SUP-3 N/A N/A 76.4 75.0 0.0 GND 12 AWG Mounted in Fan A B C D E F G H I 1 2 3 4 5 6 7 8 9 10 FACTORY WIRING SCHEMATIC CORE FIRE PROTECTION COMPONENT LIST LABEL DESCRIPTION 120 VAC RELAY NO COM COIL NC 34 6 5 8 2 7 1 RA-x 24 VDC RELAY RD-x NO COM COIL NC 34 6 5 8 2 7 1 24 VOLT BATTERY PACK 5 AMP FUSE RD SHIELDED TWISTED PAIR PCB-2 J3-2 J4-1 J3-11 J4-3 J4-2 J4-8 J4-9 J4-12 J3-14 J4-5 J3-13 J3-4 J4-6 J3-10 J2-1 J2-2 J2-3 J2-4 J7-2 J7-3 J7-1 J3-1 J3-3 RD RD BR RD ALL 18AWG RD BK ORRD PKRD BRRD RD OR/BL BK 18AWG BK BK J3-5 J1-1 J1-2 RD BK BK RD FIRE STAT SUPERVISED LOOP May be mixed factory and field wiring. See Installation Schematic. Multiple fire sensors possible. + + RD BK BK RD Shield BK RD RS-485 CORE INTERLOCK NETWORK. Connection to other CORE Panels or Communication Module. See Installation Schematic for Connection. N1D 3xH1D3x DISCONNECT J1 21 22 23 24 16AWG WH N1 H1 PN: 1606-XLP-60EQ Adjust power supply to 27.5 Volts with an accurate Digital Volt Meter or with an HMI plugged into the CORE board. NL +- PS-02 60W GR BK GND PN: PCB-2 PCBCORE-APP CORE PCB PN: PS-02 1606-XLP-60E CORE POWER SUPPLY PN: WS-x varies Water Solenoid PN: LT-06 PNL-1163-0UR 24V Red Ind. Light PN: LL-01 AQ5510 Surf. Level Sensor PN: AA-01 SCE120LA3FP1B Audible Alarm PN: PB-XX ZB4BA2/ZB4BZ1015 Prime/Reset Switch PN: SW-04 BZ-2RQ1-A2 Tamper Switch PN: SP-1 50000-805 Surfactant Pump PB-01 Prime / Reset A2A1 RD-20 Trouble Relay A2A1 RD-17 Fire Relay DRY CONTACTS (SHOWN DE-ENGERGIZED) AA-01 Audible Alarm SW-04 Door Tamper Switch C NO FS-01 BK WH Fire Stat FS-02 BK WH Fire Stat HIGH TEMP WIRE (842 F), PN: SLPCON-xFT required for all Supervised Loop wiring in contact with a hood. All other wiring shall be PN: 6320UL, Belden or similar. Factory mounted hood sensors will be terminated at junction box on top of hood. PN: GV-1 varies 24v DC Gas Valve INTERLOCK FOR AUTOMAN ACTIVATION. Used for activating 120V automan or adjacent Master CORE panels during active Fire Condition. 11 RD-18-1 14 YW J3-16 J3-8 LT-6 R FIRE INDICATOR DIP Switch ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES. RD/GNRD A2A1 RD-19 Equipment Relay COOKING EQUIPMENT DISABLE RELAY. For UDS Kill Switch, wire EKC and EKS terminals to like terminals in UDS panel. 12 11 RD-19-1 14 EKC EST EKS YW INTERLOCK FOR AUTOMAN ACTIVATION. Used for activating 120V automan or adjacent Master CORE panels during active Fire Condition. 11 RD-18-1 14 YW RD OR/BL A2A1 RD-18 Auxiliary Interlock Relay PN: FS-XX 12-F28021-000360 Duct Fire Sensor PN: LT-05 PNL-1163-0UY 24V YLW Ind. Light PN: PS-01 Station STI-SS2431 Remote Puill/Push FOR SHIPMENT J10-1 J10-2 J10-3 J10-4 RD BK BK RD 101 102 103 104 MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM LOOP. Multiple manual actuation possible. A Plug jumper with wires from pin1 to pin4 and from pin2 to pin3 should be mounted on J10 if there is no manual actuation device and no microswitch. MAD-01 C NO Manual Actuation Device MS-01 C NO Micro SW 1 2 3 4 5 6 7 8 SW 1 OPEN PUT END OF LINE PLUG IN EMPTY RJ45 J3 ECPM03 UNLESS PCU AFM OR OTHER COMPONENT IN SERIES. CAT-5 WIRING (MASTER ONLY) FIELD WIRED IF REMOTE PREWIRE PN: RD-XX PLC-RPT-24DC/21 24VDC Phoenix Relay AUX-01 AU1 AU2 Auxiliary Interlock (AUX-01): Wire AU1 / AU2 of adjacent Master CORE panel(s) in each manual activation loop for simultaneous activation. AU1/AU2 will have continuity for 10 seconds if adjacent panel goes into fire condition, activating this CORE Panel but allowing for a reset after 10 seconds. NOTE: AU1/AU2 terminals of CORE Panel should not be wired into its own manual activation loop. Adjacent CORE Panel Master CORE set DIP SW 8 to CLOSED position. Slave CORE with address 1 set DIP SW 8 to CLOSED position. All other CORES set DIP SW 8 OPEN. 18AWG LEGEND FIELD WIRING FACTORY WIRING BK- BLACK BL- BLUE BR- BROWN OR- ORANGE WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/GN STRIPE WH/BL- WH/BL STRIPE YW- YELLOW GY- GREY PR- PURPLE RD- RED GR- GREEN FIRE INDICATOR FAULT CONDITION FLASH CODES 2 Release Solenoid 3 Pressure Switch 4 Auxiliary Fault 5 Microcontroller Fault 6 N/A 7 Supervised Loop 8 Ground Fault 9 Surfactant Low 10 Battery Voltage Low 11 AC Power Failure 12 Door Tamper Switch 13 Test Mode 14 CORE Interlock Network 15 Fault on Hood in Interlock Network 16 Fault on PCU in Interlock Network FIRE ALARM SYSTEM DRY CONTACTS. Termials AL1 & AL2 make in FIRE. To Building Fire Alarm Panel J9 AL1 AL2 J3-7 FIRE SYSTEM DRY CONTACTS. Dry contacts will make C2 to AR2 when system is armed. 12 11 RD-17-1 C2 AR2 14 AWG YW TROUBLE RELAY. Contact terminals TBC & TBL make if there is trouble. Contact terminals TBC & TOK make if the system is ok. 12 11 RD-20-1 14 TBC TBL TOK YW RD PS OR J4-9 PN: PS EWC-PRESSURE Pressure Switch PR RS SW-05-1 Test Armed 3 4 YW RS-1 RELEASE SOLENOID BLBR RD OR SW-05-3 Test Armed 3 4 J4-13 PN: SW-05 ZB5AD2 TEST/ARM Switch RS2 PR SW-05-2 Test Armed 3 4 YW PS-1 Pressure Switch WH 14 PN: PWS-01 24VDC 18W POWER 24VDC Power Suppl CA CB CC AU1AU1 AU2AU2 TR2 PN: MAD-01 DEVICE MANUAL ACTIVATION GAS VALVES SHOULD BE WIRED TO MASTER CORE BOARD ONLY. RDRD GV-1 24V DC Gas Valve LGV PK TERMINAL LGV USED FOR 24VDC POWERED GAS VALVES ONLY. (2nd Contact) DWG NO JOB NO DATE DRAWN BY JOB NAME DESCRIPTION OF OPERATION TYPE DRAWING TITLE 6325918 Mo' Bettahs - Re... FACTORY DCV-2111 12/8/2023 ECP #1-8 Fire System #1 TANK FS - 4.0/4.0/4.0. FS-1: MASTER SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R C U S 6325918 MASTER DRAWING SLS 10 12/8/2023 Mo ' B e t t a h s - R e x b u r g 3/4" = 1'-0" 46 1 N o r t h 2 n d E a s t , Ut a h O f f i c e 26 9 8 S . R e d w o o d R d . , S u i t e S , W e s t V a l l e y , U T , 8 4 1 1 9 P H O N E : ( 8 0 1 ) 8 7 8 - 3 6 7 7 F A X : 9 1 9 2 2 7 5 9 5 3 E M A I L : r e g 8 7 @ c a p t i v e a i r e . c o m Re x b u r g , I D , 8 3 4 4 0 TYPICAL HOOD CONTROL PANEL INSTALLATION CONTROL PANEL. LCD INTERFACE. DUCT TEMPERATURE SENSOR. ROOM TEMPERATURE SENSOR. DEMAND CONTROL VENTILATION HOOD CONTROL PANEL SPECIFICATIONS: -CONTROLS SHALL BE LISTED BY ETL (UL 508A) AND SHALL COMPLY WITH DEMAND VENTILATION SYSTEM TURNDOWN REQUIREMENTS OUTLINED IN IECC 403.7.5 (2021). -THE CONTROL ENCLOSURE SHALL BE NEMA 1 RATED AND LISTED FOR INSTALLATION INSIDE OF THE EXHAUST HOOD UTILITY CABINET. THE CONTROL ENCLOSURE MAY BE CONSTRUCTED OF STAINLESS STEEL OR PAINTED STEEL. -TEMPERATURE PROBE(S) LOCATED IN THE EXHAUST DUCT RISER(S) SHALL BE CONSTRUCTED OF STAINLESS STEEL. -A DIGITAL CONTROLLER SHALL BE PROVIDED TO ACTIVATE THE HOOD EXHAUST FANS DYNAMICALLY BASED ON A FIXED DIFFERENTIAL BETWEEN THE AMBIENT AND DUCT TEMPERATURES SENSORS. THIS FUNCTION SHALL MEET THE REQUIREMENTS OF IMC 507.1.1. -A DIGITAL CONTROLLER SHALL PROVIDE ADJUSTABLE HYSTERESIS SETTINGS TO PREVENT CYCLING OF THE FANS AFTER THE COOKING APPLIANCES HAVE BEEN TURNED OFF AND/OR THE HEAT IN THE EXHAUST SYSTEM IS REDUCED. -A DIGITAL CONTROLLER SHALL PROVIDE AN ADJUSTABLE MINIMUM FAN RUN-TIME SETTING TO PREVENT FAN CYCLING. -VARIABLE FREQUENCY DRIVES (VFDS) SHALL BE PROVIDED FOR FANS AS REQUIRED. THE DIGITAL CONTROLLER SHALL MODULATE THE VFDS BETWEEN A MINIMUM SETPOINT AND A MAXIMUM SETPOINT ON DEMAND. THE DUCT TEMPERATURE SENSOR INPUT(S) TO THE DIGITAL CONTROLLER SHALL BE USED TO CALCULATE THE SPEED REFERENCE SIGNAL. -THE VFD SPEED RANGE OF OPERATION SHALL BE FROM 0% TO 100% FOR THE SYSTEM, WITH THE ACTUAL MINIMUM SPEED SET AS REQUIRED TO MEET MINIMUM VENTILATION REQUIREMENTS. -AN INTERNAL ALGORITHM TO THE DIGITAL CONTROLLER SHALL MODULATE SUPPLY FAN VFD SPEED PROPORTIONAL TO ALL EXHAUST FANS THAT ARE LOCATED IN THE SAME FAN GROUP AS THE SUPPLY FAN. -THE SYSTEM SHALL OPERATE IN PREP MODE DURING LIGHT COOKING LOAD OR COOL DOWN MODE WHEN SUFFICIENT HEAT REMAINS UNDERNEATH THE HOOD SYSTEM AFTER COOKING OPERATIONS HAVE COMPLETED. OPERATION DURING EITHER OF THESE PERIODS WILL DISABLE THE SUPPLY FANS AND PROVIDE AN EXHAUST FAN SPEED THAT IS EQUAL TO THE MINIMUM VENTILATION REQUIREMENT. -A DIGITAL CONTROLLER SHALL DISABLE THE SUPPLY FAN(S), ACTIVATE THE EXHAUST FAN(S), ACTIVATE THE APPLIANCE SHUNT TRIP, AND DISABLE AN ELECTRIC GAS VALVE AUTOMATICALLY WHEN FIRE CONDITION IS DETECTED ON A COVERED HOOD. -A DIGITAL CONTROLLER SHALL ALLOW FOR EXTERNAL BMS FAN CONTROL VIA DRY CONTACT (EXTERNAL CONTROL SHALL NOT OVERRIDE FAN OPERATION LOGIC AS REQUIRED BY CODE). -AN LCD INTERFACE SHALL BE PROVIDED WITH THE FOLLOWING FEATURES: A. ON/OFF PUSH BUTTON FAN & LIGHT SWITCH ACTIVATION. B. INTEGRATED GAS VALVE RESET FOR ELECTRONIC GAS VALVES (NO RESET RELAY REQUIRED). C. VFD FAULT DISPLAY WITH AUDIBLE & VISUAL ALARM NOTIFICATION. D. DUCT TEMPERATURE SENSOR FAILURE DETECTION WITH AUDIBLE & VISUAL ALARM NOTIFICATION. E. MIS-WIRED DUCT TEMPERATURE SENSOR DETECTION WITH AUDIBLE & VISUAL ALARM NOTIFICATION. F. A SINGLE LOW VOLTAGE CAT-5 RJ45 WIRING CONNECTION. G. AN ENERGY SAVINGS INDICATOR THAT UTILIZES MEASURED KWH FROM THE VFDS. SEQUENCE OF OPERATIONS: THE HOOD CONTROL PANEL IS CAPABLE OF OPERATING IN ONE OR MORE OF THE FOLLOWING STATES AT ANY GIVEN TIME: -AUTOMATIC: THE SYSTEM OPERATES BASED ON THE DIFFERENTIAL BETWEEN ROOM TEMPERATURE AND THE TEMPERATURE AT THE HOOD CAVITY OR EXHAUST DUCT COLLAR. FANS ACTIVATE AT A CONFIGURABLE TEMPERATURE DIFFERENTIAL THRESHOLD. DEPENDING ON THE JOB CONFIGURATION EACH FAN ZONE CAN BE CONFIGURED AS STATIC OR DYNAMIC. THESE TERMS REFER TO WHETHER A VARIABLE MOTOR (SUCH AS EC MOTORS OR VFD DRIVEN MOTORS) MODULATE WITH TEMPERATURE. IF THE PANEL IS EQUIPPED WITH VARIABLE SPEED FANS AND THE ZONE IS DEFINED AS "DYNAMIC", THESE WILL MODULATE WITHIN A USER-DEFINED RANGE BASED ON THE TEMPERATURE DIFFERENTIAL. PANELS EQUIPPED WITH VARIABLE SPEED FANS AND A FAN ZONE DEFINED AS "STATIC", FANS WILL RUN AT A SET SPEED CALCULATED FOR THE DRIVE. DEMAND CONTROL VENTILATION SYSTEMS ARE CAPABLE OF MODULATING EXHAUST AND MAKE UP AIR FAN SPEEDS PER THE REQUIREMENTS OUTLINED IN IECC 403.7.5 (2021). -MANUAL: THE SYSTEM OPERATES BASED ON HUMAN INPUT FROM AN HMI. -SCHEDULE: A WEEKLY SCHEDULE CAN BE SET TO RUN FANS FOR A SPECIFIED PERIOD THROUGHOUT THE DAY. THERE ARE THREE OCCUPIED TIMES PER DAY TO ALLOW FOR THE USER TO SET UP A TIME THAT IS SUITABLE TO THEIR NEEDS. ANY TIME THAT IS WITHIN THE DEFINED OCCUPIED TIME, THE SYSTEM WILL RUN AT MODULATION MODE AND FOLLOW THE FAN PROCEDURE ALGORITHM BASED ON TEMPERATURE DURING THIS TIME. DURING UNOCCUPIED TIME, THE SYSTEM WILL HAVE AN EXTRA OFFSET TO PREVENT UNINTENDED ACTIVATION OF THE SYSTEM DURING A TIME WHERE THE SYSTEM IS NOT BEING OCCUPIED. -OTHER: THE SYSTEM OPERATES BASED ON THE INPUT FROM AN EXTERNAL SOURCE (DDC, BMS OR HARD-WIRED INTERLOCK). FIRE:UPON ACTIVATION OF THE HOOD FIRE SUPPRESSION SYSTEM, THE EXHAUST FAN WILL COME ON OR CONTINUE TO TO RUN, THE HOOD MAKEUP AIR WILL SHUTDOWN, AND A SIGNAL WILL BE SENT FOR ACTIVATING THE SHUNT TRIP BREAKER PROVIDED BY THE ELECTRICIAN. FUEL GAS WILL SHUT OFF VIA A MECHANICAL/ELECTRICAL GAS VALVE ACTUATED BY THE HOOD FIRE SUPPRESSION SYSTEM. - SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R C U S 6325918 MASTER DRAWING SLS 11 12/8/2023 Mo ' B e t t a h s - R e x b u r g 3/4" = 1'-0" 46 1 N o r t h 2 n d E a s t , Ut a h O f f i c e 26 9 8 S . R e d w o o d R d . , S u i t e S , W e s t V a l l e y , U T , 8 4 1 1 9 P H O N E : ( 8 0 1 ) 8 7 8 - 3 6 7 7 F A X : 9 1 9 2 2 7 5 9 5 3 E M A I L : r e g 8 7 @ c a p t i v e a i r e . c o m Re x b u r g , I D , 8 3 4 4 0