HOOD INFORMATION - JOB#6325918
1
2
H-1
H-2
5424
ND-2
5424
ND-2
CAPTIVEAIRE
CAPTIVEAIRE
10' 10"
7' 9"
600
DEG
600
DEG
I
I
HEAVY
HEAVY
300
175
3250
1356
4"
4"
18"
12"
3250
1356
1839
1727
-1.208"
-0.581"
430 SS
WHERE EXPOSED
430 SS
WHERE EXPOSED
ALONE
ALONE
ALONE
ALONE
HOOD
NO
TAG MODEL MANUFACTURER LENGTH
MAX
COOKING
TEMP
TYPE
APPLIANCE
DUTY
DESIGN
CFM/FT
TOTAL
EXH CFM
EXHAUST PLENUM
RISER(S)
WIDTH LENG HEIGHT DIA CFM VEL SP
HOOD
CONSTRUCTION
HOOD CONFIG
END TO
END
ROW
HOOD INFORMATION
1
2
H-1
H-2
CAPTRATE SOLO FILTER
CAPTRATE SOLO FILTER
8
5
20"
20"
16"
16"
85% SEE FILTER
SPEC
85% SEE FILTER
SPEC
4
3
L55 SERIES E26
L55 SERIES E26
NO
NO RIGHT 12"x54"x24"TANK FS 4.0/4.0/4.0 DCV-2111
1 LIGHT
1 FAN
YES
YES
493
LBS
767
LBS
HOOD
NO
TAG
FILTER(S)
TYPE QTY HEIGHT LENGTH
EFFICIENCY @ 7
MICRONS
LIGHT(S)
QTY TYPE
WIRE
GUARD
UTILITY CABINET(S)
LOCATION SIZE
FIRE SYSTEM
TYPE SIZE
ELECTRICAL
MODEL #
SWITCHES
QUANTITY
FIRE
SYSTEM
PIPING
HOOD
HANGING
WEIGHT
HOOD OPTIONS
1
2
H-1
H-2
FIELD WRAPPER 4.00" HIGH FRONT.
BACKSPLASH 122.00" HIGH X 132.00" LONG 430 SS VERTICAL.
LEFT SIDESPLASH 122.00" HIGH X 40.00" LONG 430 SS VERTICAL.
RIGHT SIDESPLASH 122.00" HIGH X 48.00" LONG 430 SS VERTICAL.
RIGHT END STANDOFF (FINISHED) 1" WIDE 54" LONG INSULATED.
LEFT END STANDOFF (FINISHED) 1" WIDE 54" LONG INSULATED.
WRAPPER CHANNEL - LEFT, RIGHT.
BACKSPLASH - INSIDE CORNER 122.00" HIGH X 2.00" LEG LENGTH 430 SS VERTICAL.
BACKSPLASH - INSIDE CORNER 122.00" HIGH X 2.00" LEG LENGTH 430 SS VERTICAL.
STRUCTURAL FRONT PANEL.
WALL END CAP 122.00" HIGH X 5.00" WALL WIDTH, 2.00" LEGS 430 SS.
WALL END CAP 122.00" HIGH X 5.00" WALL WIDTH, 2.00" LEGS 430 SS.
RIGHT WALL AS END PANEL.
LEFT WALL AS END PANEL.
FIELD WRAPPER 4.00" HIGH FRONT, RIGHT.
BACKSPLASH 122.00" HIGH X 124.00" LONG 430 SS VERTICAL.
LEFT END STANDOFF (FINISHED) 1" WIDE 54" LONG INSULATED.
RIGHT QUARTER END PANEL 23" TOP WIDTH, 0" BOTTOM WIDTH, 23" HIGH 430 SS.
RISER SENSOR INSTALL 6IN PLEN.
LEFT WALL AS END PANEL.
HOOD
NO
TAG OPTION
PATENT NUMBERS
EXHAUST HOODS ND-2/BD-2/SND-2 (CANADA) - CA PATENT 2520435 C.
SYSTEM DESIGN VERIFICATION (SDV)
IF ORDERED, CAS SERVICE WILL PERFORM A SYSTEM DESIGN VERIFICATION (SDV) ONCE ALL
EQUIPMENT HAS HAD A COMPLETE START UP PER THE OPERATION AND INSTALLATION MANUAL.
TYPICALLY, THE SDV WILL BE PERFORMED AFTER ALL INSPECTIONS ARE COMPLETE.
ANY FIELD RELATED DISCREPANCIES THAT ARE DISCOVERED DURING THE SDV WILL BE BROUGHT TO
THE
ATTENTION OF THE GENERAL CONTRACTOR AND CORRESPONDING TRADES ON SITE. THESE ISSUES
WILL BE DOCUMENTED AND FORWARDED TO THE APPROPRIATE SALES OFFICE. IF CAS SERVICE HAS
TO
RESOLVE A DISCREPANCY THAT IS A FIELD ISSUE, THE GENERAL CONTRACTOR WILL BE NOTIFIED AND
BILLED FOR THE WORK. SHOULD A RETURN TRIP BE REQUIRED DUE TO ANY FIELD RELATED
DISCREPANCY THAT CANNOT BE RESOLVED DURING THE SDV, THERE WILL BE ADDITIONAL TRIP
CHARGES.
DURING THE SDV, CAS SERVICE WILL ADDRESS ANY DISCREPANCY THAT IS THE FAULT OF THE
MANUFACTURER. SHOULD A RETURN TRIP BE REQUIRED, THE GENERAL CONTRACTOR AND APPROPRIATE
SALES OFFICE WILL BE NOTIFIED. THERE WILL BE NO ADDITIONAL CHARGES FOR MANUFACTURER
DISCREPANCIES.
Hood)
(30" High
studs on the inside wall of the hood
Grease Cup will be supported by 2
concealed grease trough and into this
HANGING ANGLE
1/2 Pint Grease Cup Detail
ONE ABOVE AND TWO BELOW
1/2" DIA. HEAVY DUTY NUT
ROD AND NUTS TO BE SUPPLIED BY INSTALLING CONTRACTOR
IN THE FOLLOWING LOCATIONS
ND-2 HANGING ANGLE DETAIL
HANGING ANGLES WILL BE LOCATED
FROM
DIM
FRONT
HANGING ANGLE LOCATIONS
Hood)
Condensate
2.25"2.25"
Wall
Back
Shelf
4.166"
Exhaust
Only
With
MUA
2.25"
2.25"
4.166"
Only
Exhaust
With
MUA
2.25"
2.25"
HOOD STYLE
FOR WALL CANOPIES
FROM
DIM
REAR
(24" High
DIM
FROM
FRONT
HANGING ANGLE IS PRE-PUNCHED AT FACTORY
*
removable cup.
ANGLE
THROUGH ANOTHER HANGING
CONNECTED TO ROOF JOIST
1/2" DIA. ALL THREAD ROD
The grease will drain through a
2.25"
2.25"
2.25"
2.25"
CALCULATIONS UTILIZED
VELOCITY OF 1600-1800 FPM AND A SUPPLY VELOCITY OF 1000 FPM
PLEASE CONSULT FACTORY FOR MAXIMUM ALLOWABLE DUCT SIZES
FPM(*)
DUCT DEPTH
TOTAL DUCT AREA
EXHAUST CFM=LENGTH OF HOOD X CFM/LIN.FT. (LOAD)
SUPPLY CFM=EXHAUST CFM X PERCENTAGE REQUIRED
CAPTIVE-AIRE VENTILATOR DUCT SIZES ARE CALCULATED USING AN EXHAUST
DUCT LENGTH=
TOTAL DUCT AREA=144 X
*
CFM
BUILDING CODES
2" Captrate Grease-Stop Solo Filter
RESISTANCE VS. AIRFLOW
1.6
1.4
1
1.2
1000800600
0.8
0.4
0.6
4002000
0
0.2
RE
S
I
S
T
A
N
C
E
(
i
n
.
H
2
0
)
AIRFLOW (cfm)
CAPTRATE
Filter Detail
R
R
Captrate
Grease-Stop Solo Filter
CAPTIVE-AIRE HOODS ARE BUILT IN COMPLIANCE WITH:
D
R
T
TA
S
INA
C
IS
L
NOI
D
E
T
M
Intertek
SI ETL
ETL SANITATION
E.T.L. LISTED 3054804-001
ETL IS LISTED TO ULC STANDARDS
*
*
*
NFPA #96
*
R
NSF
*
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
C
U
S
6325918
MASTER DRAWING
SLS
1
12/8/2023
Mo
'
B
e
t
t
a
h
s
-
R
e
x
b
u
r
g
3/4" = 1'-0"
46
1
N
o
r
t
h
2
n
d
E
a
s
t
,
Ut
a
h
O
f
f
i
c
e
26
9
8
S
.
R
e
d
w
o
o
d
R
d
.
,
S
u
i
t
e
S
,
W
e
s
t
V
a
l
l
e
y
,
U
T
,
8
4
1
1
9
P
H
O
N
E
:
(
8
0
1
)
8
7
8
-
3
6
7
7
F
A
X
:
9
1
9
2
2
7
5
9
5
3
E
M
A
I
L
:
r
e
g
8
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
Re
x
b
u
r
g
,
I
D
,
8
3
4
4
0
10' 10"NOM./10' 10.00"OD.
11'-0.00" OVERALL LENGTH
54"
1" LAYER OF INSULATION
FACTORY INSTALLED IN
1.00" END STANDOFF MEETS
0" REQUIREMENTS CLEARANCE
TO COMBUSTIBLE SURFACES.
1"
1" LAYER OF INSULATION
FACTORY INSTALLED IN
1.00" END STANDOFF MEETS
0" REQUIREMENTS CLEARANCE
TO COMBUSTIBLE SURFACES.
1"
3"
§
53"77"
12"
∅18"
U.L. LISTED L55 SERIES E26 CANOPY
LIGHT FIXTURE - HIGH TEMP ASSEMBLY.
INSTALLER MUST CONFIRM HOOD IS INSTALLED SUCH
THAT THE SPECIFIED WALL, ACTING AS AN END PANEL,
IS MATED TIGHT TO THE CORRECT END OF HOOD TO
ACHIEVE A REDUCED MINIMUM EXHAUST CFM LISTING.
NON-COMPLIANCE WILL NULLIFY THE ETL LISTING,
VOID THE MANUFACTURER'S WARRANTY, AND HOLD THE
CONTRACTOR LIABLE FOR ANY AND ALL LOSSES, COSTS,
AND EXPENSES RELATED TO THE NON-CONFORMANCE OF
THE MANUFACTURER'S SPECIFIED INSTRUCTION. THE
WALL ACTING AS AN END PANEL MUST EXTEND NO LESS
THAN 20" FROM THE INTERSECTING WALL ON WHICH HOOD
IS MOUNTED AND MUST EXTEND NO LESS THAN 20" UNDER
BOTTOM OF HOOD TO BE ELIGIBLE FOR REDUCED
MINIMUM EXHAUST CFM LISTING.
PLAN VIEW - HOOD #1 (H-1)
10' 10.00" LONG 5424ND-2
7' 9"NOM./7' 9.00"OD.
8'-10.00" OVERALL LENGTH
54"
12"
UTILITY
CABINET.
SC
-
2
0
X
1
8
X
8
.
6
2
B
O
X
1" LAYER OF INSULATION
FACTORY INSTALLED IN
1.00" END STANDOFF MEETS
0" REQUIREMENTS CLEARANCE
TO COMBUSTIBLE SURFACES.
1"
3"
§
46 1/2"46 1/2"
10"
∅12"
U.L. LISTED L55 SERIES E26 CANOPY
LIGHT FIXTURE - HIGH TEMP ASSEMBLY.
INSTALLER MUST CONFIRM HOOD IS INSTALLED SUCH
THAT THE SPECIFIED WALL, ACTING AS AN END PANEL,
IS MATED TIGHT TO THE CORRECT END OF HOOD TO
ACHIEVE A REDUCED MINIMUM EXHAUST CFM LISTING.
NON-COMPLIANCE WILL NULLIFY THE ETL LISTING,
VOID THE MANUFACTURER'S WARRANTY, AND HOLD THE
CONTRACTOR LIABLE FOR ANY AND ALL LOSSES, COSTS,
AND EXPENSES RELATED TO THE NON-CONFORMANCE OF
THE MANUFACTURER'S SPECIFIED INSTRUCTION. THE
WALL ACTING AS AN END PANEL MUST EXTEND NO LESS
THAN 20" FROM THE INTERSECTING WALL ON WHICH HOOD
IS MOUNTED AND MUST EXTEND NO LESS THAN 20" UNDER
BOTTOM OF HOOD TO BE ELIGIBLE FOR REDUCED
MINIMUM EXHAUST CFM LISTING.
PLAN VIEW - HOOD #2 (H-2)
7' 9.00" LONG 5424ND-2
3" INTERNAL STANDOFF.
GREASE DRAIN
WITH REMOVABLE CUP.
SEE HOOD TABLE.
§
EXHAUST RISER.
HANGING ANGLE.
L55 SERIES E26 CANOPY LIGHT FIXTURE -
HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL
AND SHOCK RESISTANT GLOBE (L55 FIXTURE).
BACKSPLASH 122.00" HIGH
X 132.00" LONG.
FIELD WRAPPER 4.00" HIGH
(SEE HOOD OPTIONS TABLE).
LEFT AND RIGHT WALL AS END PANELS.
EQUIPMENT
BY OTHERS.
48.0" MAX.
80"
24" NOM.
54"
SECTION VIEW - MODEL 5424ND-2
HOOD - #1 (H-1)
IT IS THE RESPONSIBILITY
OF THE ARCHITECT/OWNER TO
ENSURE THAT THE HOOD CLEARANCE
FROM LIMITED-COMBUSTIBLE
AND COMBUSTIBLE MATERIALS
IS IN COMPLIANCE WITH
LOCAL CODE REQUIREMENTS.
20" CAPTRATE SOLO
FILTER WITH HOOK.
3" INTERNAL STANDOFF.
GREASE DRAIN
WITH REMOVABLE CUP.
SEE HOOD TABLE.
§
EXHAUST RISER.
HANGING ANGLE.
L55 SERIES E26 CANOPY LIGHT FIXTURE -
HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL
AND SHOCK RESISTANT GLOBE (L55 FIXTURE).
BACKSPLASH 122.00" HIGH
X 124.00" LONG.
FIELD WRAPPER 4.00" HIGH
(SEE HOOD OPTIONS TABLE).
23"
23"
RIGHT QUARTER END PANEL.
LEFT WALL AS END PANEL.
EQUIPMENT
BY OTHERS.
48.0" MAX.
80"
24" NOM.
54"
SECTION VIEW - MODEL 5424ND-2
HOOD - #2 (H-2)
IT IS THE RESPONSIBILITY
OF THE ARCHITECT/OWNER TO
ENSURE THAT THE HOOD CLEARANCE
FROM LIMITED-COMBUSTIBLE
AND COMBUSTIBLE MATERIALS
IS IN COMPLIANCE WITH
LOCAL CODE REQUIREMENTS.
20" CAPTRATE SOLO
FILTER WITH HOOK.
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
C
U
S
6325918
MASTER DRAWING
SLS
2
12/8/2023
Mo
'
B
e
t
t
a
h
s
-
R
e
x
b
u
r
g
3/4" = 1'-0"
46
1
N
o
r
t
h
2
n
d
E
a
s
t
,
Ut
a
h
O
f
f
i
c
e
26
9
8
S
.
R
e
d
w
o
o
d
R
d
.
,
S
u
i
t
e
S
,
W
e
s
t
V
a
l
l
e
y
,
U
T
,
8
4
1
1
9
P
H
O
N
E
:
(
8
0
1
)
8
7
8
-
3
6
7
7
F
A
X
:
9
1
9
2
2
7
5
9
5
3
E
M
A
I
L
:
r
e
g
8
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
Re
x
b
u
r
g
,
I
D
,
8
3
4
4
0
FIRE SYSTEM INFORMATION - JOB#6325918
1 TANK FS 4.0/4.0/4.0 60 55 FIRE CABINET RIGHT RIGHT, HOOD 2
FIRE
SYSTEM
NO
TAG TYPE SIZE MAX FP
DESIGN
FP
INSTALLATION
SYSTEM LOCATION ON HOOD
GAS VALVE(S)
1 SC ELECTRICAL 1.500 CAPTIVEAIRE SYSTEMS
FIRE
SYSTEM
NO
TAG TYPE SIZE SUPPLIED BY
FIRE SYSTEM PARTS LIST KEY
1
0 - 0 - TANK FIRE SUPPRESSION POST-DISCHARGE PROCEDURE UTILITY CABINET LABEL SHEET.
0 - 0 - TANK FIRE SUPPRESSION MAINTENANCE GUIDE UTILITY CABINET LABEL SHEET.
0 - 0 - 12-F28021-32144-OT-360 DUCT FIRE THERMOSTAT WITH 12 FOOT WIRE LEADS. NO,
CLOSE ON TEMP RISE AT 360°F.
0 - 0 - 32-00002 QUIK SEAL - 1/2" (UL).
0 - 0 - 361091 3/8" BRASS PLUG.
0 - 0 - 4429K153 1/2" MALE NPT TO 1/2" FEMALE NPT ELBOW, BRASS.
0 - 0 - 4429K422 1/2" X 1/4" BRASS REDUCING BUSHING.
0 - 0 - 79425 3/8" NPT FEMALE TO 1/2" MALE PROPRESS ADAPTER.
0 - 0 - 79525 1/2" 90 PRO-PRESS ELBOW WITH 1/2” NPT FEMALE CONNECTION, VIEGA.
0 - 0 - 79580 1/2" X 1/2" PRO-PRESS TEE X 1/2” NPT FEMALE CONNECTION, VIEGA.
0 - 0 - 87-120042-001 SECONDARY ACTUATOR VALVE (SVA) - SINGLE ACTUATOR, REQUIRES
PRIMARY RELEASE ACTUATOR, TANK FIRE SUPPRESSION.
0 - 0 - 87-120045-001 HOSE, SECONDARY ACTUATOR HOSE, 7.5" BRAIDED STAINLESS STEEL,
TANK FIRE SUPPRESSION.
0 - 0 - 87-300001-001 TANK - PRESSURIZED TANK USED FOR TANK FIRE SUPPRESSION.
0 - 0 - 87-300030-001 PRIMARY ACTUATOR KIT (PAK) - ACTUATOR AND RELEASE SOLENOID
ASSEMBLY, ONE NEEDED PER FIRE SYSTEM, SUPERVISED, TANK FIRE SUPPRESSION.
0 - 0 - 87-300152-001 HARDWARE, SVA BOLTS, TANK FIRE SUPPRESSION.
0 - 0 - 9055455PC PRO PRESS 1/2 PRESS X PRESS 90 ELBOW LD.
0 - 0 - 9097200PC PRO PRESS PC611 1/2 PRESS TEE LD.
0 - 0 - 98694A115 HARDWARE, DATANKLOCK LOCKING BRACKET SQUARE NUTS 5/16" ZINC, TANK
FIRE SUPPRESSION.
0 - 0 - A0034332 JUNCTION BOX FOR MANUAL PULL STATION. 1.5" DEEP BACK BOX, RED COLOR.
0 - 0 - A31484 1/4" NPT SCHRADER VALVE AND CAP, JB INDUSTRIES. 1/4" FLARE X 1/4"
MPT HALF UNION. USED ON TANK SERVICE PORT.
0 - 0 - BI145 3/8" BLACK IRON 90 ELL.
0 - 0 - DATANKLOCK DISCHARGE ADAPTER TANK LOCKING PLATE FOR FIRE SYSTEM TANK INSTALLATION
IN UTILITY CABINETS, TANK FIRE SUPPRESSION.
0 - 0 - SLPCON-03FT SUPERVISED LOOP CONNECTION KIT. CONTAINS THE PARTS NEEDED TO
CONNECT THE SUPERVISED LOOP BETWEEN END TO END HOODS WITH LESS THAN A 2' GAP. KIT
CONTAINS 5 FEET OF BLACK MG WIRE, 5 FEET OF TAN MG WIRE, 3 FEET OF FLEXIBLE CONDUIT,
AND TWO 7/8" CONNECTORS.
0 - 0 - SLPCON-15FT SUPERVISED LOOP CONNECTION KIT. CONTAINS THE PARTS NEEDED TO
CONNECT THE SUPERVISED LOOP BETWEEN END TO END HOODS WITH LESS THAN A 14' GAP OR
BACK TO BACK HOODS. KIT CONTAINS 17 FEET OF BLACK MG WIRE, 17 FEET OF TAN MG WIRE,
15 FEET OF FLEXIBLE CONDUIT, AND TWO 7/8" CONNECTORS.
0 - 0 - TANK STRAP TANK STRAP - USED FOR TANK FIRE SUPPRESSION.
0 - 0 - TFS-UCTANKBRACKET TANK BRACKET FOR FIRE SYSTEM TANK INSTALLATION IN UTILITY
CABINETS, TANK FIRE SUPPRESSION.
0 - 0 - WK-283952-000 DISCHARGE ADAPTER, TANK FIRE SUPPRESSION.
16 - 16 - 79210 1/2" X 3/8" NPT MALE ADAPTER, VIEGA.
16 - 16 - OL-F NOZZLE - TANK PROTECTION APPLIANCE COVERAGE NOZZLE (INCLUDES METAL
BLOW OFF CAP, LANYARD, USED WITH CHROME-PLATED PIPE).
26 - 26 - QSA-3/8 QUIK SEAL - 3/8" (UL).
34 - 34 - A0034331 24VDC SINGLE ACTION MANUAL ACTUATION DEVICE (PUSH/PULL STATION)
WITH PROTECTIVE COVER, ONE (1) NORMALLY OPEN CONTACT. RED COLOR.
1
1
2
2
3
3
2
3
2
3
2
2
3
1
12
11
11
6
1
2
5
3
1
2
9
3
3
12
12
12
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
FIRE
SYSTEM
NO
TAG KEY NUMBER - PART DESCRIPTION
QTY BY
FACTORY
QTY BY
DIST
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
C
U
S
6325918
MASTER DRAWING
SLS
3
12/8/2023
Mo
'
B
e
t
t
a
h
s
-
R
e
x
b
u
r
g
3/4" = 1'-0"
46
1
N
o
r
t
h
2
n
d
E
a
s
t
,
Ut
a
h
O
f
f
i
c
e
26
9
8
S
.
R
e
d
w
o
o
d
R
d
.
,
S
u
i
t
e
S
,
W
e
s
t
V
a
l
l
e
y
,
U
T
,
8
4
1
1
9
P
H
O
N
E
:
(
8
0
1
)
8
7
8
-
3
6
7
7
F
A
X
:
9
1
9
2
2
7
5
9
5
3
E
M
A
I
L
:
r
e
g
8
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
Re
x
b
u
r
g
,
I
D
,
8
3
4
4
0
FACTORY PIPING EXTENDS A MAXIMUM
OF 6" ABOVE THE TOP OF THE HOOD.
12"
∅18"
HOOD FRONT
HOOD BACK
HOOD # 1 (H-1) JOB # 6325918 FS # 1
MODEL: ND-2 SIZE: 54"x24" LENGTH: 10' 10"
TA
N
K
O
V
E
R
L
A
P
P
I
N
G
PR
O
T
E
C
T
I
O
N
-
3
0
HI
G
H
P
R
O
X
I
M
I
T
Y
11
8
.
0
0
"
L
X
3
0
.
0
0
"
D
DUCT
S
360
OL-F
OL-F OL-F
25.00"
21.50"
OL-F
21.50"
OL-F
21.50"
OL-F
21.50"
OL-F
21.50"
OL-F
NOZZLE HEIGHT
35-50" FROM
COOKING SURFACE.
(45.25")
17.80"23.60"23.60"23.60"23.60"17.80"
SLPCON-15FT
KIT
FACTORY PIPING EXTENDS A MAXIMUM
OF 6" ABOVE THE TOP OF THE HOOD.
10"
∅12"
HOOD FRONT
HOOD BACK
HOOD # 2 (H-2) JOB # 6325918 FS # 1
MODEL: ND-2 SIZE: 54"x24" LENGTH: 7' 9"
TA
N
K
O
V
E
R
L
A
P
P
I
N
G
PR
O
T
E
C
T
I
O
N
-
3
0
HI
G
H
P
R
O
X
I
M
I
T
Y
39
.
0
0
"
L
X
1
8
.
0
0
"
D
DUCT
S
360
OL-F
OL-F
25.00"
21.50"
OL-F
21.50"
OL-F
NOZZLE HEIGHT
35-50" FROM
COOKING SURFACE.
(45.25")
57.75"19.50"15.75"
SLPCON-15FT
KIT
SLPCON-03FT
KIT
- SYSTEM REQUIRES A MINIMUM OF 7 FT OF
EQUIVALENT PIPE LENGTH BETWEEN TANK AND
NEAREST APPLIANCE NOZZLE FOR MOST APPLIANCES.
EACH 90 DEGREE ELBOW ADDS 1.3 FT OF
EQUIVALENT LENGTH. SEE MANUAL FOR DETAILS
1
631
1 3
7
6
2 5
ALTERNATE FIELD-CONNECTION POINT
PL
E
N
U
M
PL
E
N
U
M
PL
E
N
U
M
NOTES
- FIELD PIPE DROPS AS SHOWN
PIPING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS.
- FIELD INSTALLED DROP: FACTORY WILL PROVIDE QTY 2 60IN LONG PIECES OF CHROME
PLATED PIPING SHIPPED LOOSE TO BE FIELD-INSTALLED.
- SHIP LOOSE DROP: FACTORY WILL PROVIDE THE EXACT CHROME PIPE LENGTH NEEDED
SHIPPED LOOSE TO BE FIELD-INSTALLED.
- RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING,
SALAMANDERS, ETC.
- OVERLAPPING COVERAGE SHALL NOT BE USED ON ANY APPLIANCE WITH AN OBSTRUCTION.
- IF APPLICABLE, EXTENDED PRE-PIPED DROPS ARE SHIPPED LOOSE.
- FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD.
- APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE
SIZE, NOT THE OVERALL APPLIANCE SIZE.
- THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS.
- OL-F NOZZLE PART NUMBER REPLACES 3070-3/8H-10-SS
JOB #: 6325918.
JOB NAME: MO' BETTAHS - REXBURG.
SYSTEM SIZE: TANK-SP-3 DESIGN FP: 55. MAXIMUM FP: 60.
HOOD # 1 10' 10.00" LONG x 54" WIDE x 24" HIGH.
RISER # 1 SIZE: 18" DIA.
HOOD # 1 METAL BLOW-OFF CAPS INCLUDED.
HOOD # 2 7' 9.00" LONG x 54" WIDE x 24" HIGH.
RISER # 1 SIZE: 12" DIA.
HOOD # 2 METAL BLOW-OFF CAPS INCLUDED.
- HEAVY-DUTY APPLIANCES (RATED 600°F) WILL REQUIRE AN ADDITIONAL
DOWNSTREAM FIRESTAT IN THE EVENT THAT THE DUCTWORK CONTAINS ANY
HORIZONTAL RUNS OVER 25 FT IN LENGTH.
- MEDIUM TO LIGHT-DUTY APPLIANCES (RATED 450°F) WILL NOT REQUIRE
ANY ADDITIONAL DOWNSTREAM DETECTION.
PRESSURE SUPERVISION SWITCH.
PRIMARY ACTUATOR RELEASE.
4 GALLON TANK.
7
6
5
4
2
1
LEGEND - FIRE CABINET TANK SYSTEM
PRIMARY HOSE ASSEMBLY.
SECONDARY ACTUATOR RELEASE.3
SECONDARY HOSE ASSEMBLY.
REMOTE MANUAL ACTUATION DEVICE.
3" INTERNAL STANDOFF.
GREASE DRAIN
WITH REMOVABLE CUP.
SEE HOOD TABLE.
§
EXHAUST RISER.
HANGING ANGLE.
L55 SERIES E26 CANOPY LIGHT FIXTURE -
HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL
AND SHOCK RESISTANT GLOBE (L55 FIXTURE).
BACKSPLASH 122.00" HIGH
X 132.00" LONG.
FIELD WRAPPER 4.00" HIGH
(SEE HOOD OPTIONS TABLE).
LEFT AND RIGHT WALL AS END PANELS.
EQUIPMENT
BY OTHERS.
48.0" MAX.
80"
24" NOM.
54"
SECTION VIEW - MODEL 5424ND-2
HOOD - #1
IT IS THE RESPONSIBILITY
OF THE ARCHITECT/OWNER TO
ENSURE THAT THE HOOD CLEARANCE
FROM LIMITED-COMBUSTIBLE
AND COMBUSTIBLE MATERIALS
IS IN COMPLIANCE WITH
LOCAL CODE REQUIREMENTS.
20" CAPTRATE SOLO
FILTER WITH HOOK.
21 1/2"
3" INTERNAL STANDOFF.
GREASE DRAIN
WITH REMOVABLE CUP.
SEE HOOD TABLE.
§
EXHAUST RISER.
HANGING ANGLE.
L55 SERIES E26 CANOPY LIGHT FIXTURE -
HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL
AND SHOCK RESISTANT GLOBE (L55 FIXTURE).
BACKSPLASH 122.00" HIGH
X 124.00" LONG.
FIELD WRAPPER 4.00" HIGH
(SEE HOOD OPTIONS TABLE).
23"
23"
RIGHT QUARTER END PANEL.
LEFT WALL AS END PANEL.
EQUIPMENT
BY OTHERS.
48.0" MAX.
80"
24" NOM.
54"
SECTION VIEW - MODEL 5424ND-2
HOOD - #2
IT IS THE RESPONSIBILITY
OF THE ARCHITECT/OWNER TO
ENSURE THAT THE HOOD CLEARANCE
FROM LIMITED-COMBUSTIBLE
AND COMBUSTIBLE MATERIALS
IS IN COMPLIANCE WITH
LOCAL CODE REQUIREMENTS.
20" CAPTRATE SOLO
FILTER WITH HOOK.
21 1/2"
INCLUDES: FIELD INSTALLATION AND HOOKUP DURING NORMAL BUSINESS HOURS
BY CERTIFIED INSTALLERS ONLY IN THE LOCATION NOTED ABOVE, TWO SITE
VISITS ONLY (ONE VISIT TO SET PULL STATION & SYSTEM HOOKUP AND ONE
VISIT FOR ONE TEST; ADDITIONAL VISITS WILL RESULT IN ADDITIONAL
CHARGES), ONE MECHANICAL OR ELECTRICAL GAS VALVE PER SYSTEM AT A
MAXIMUM SIZE OF 2", PERMIT, AND SYSTEM TEST.
EXCLUDES: UNION LABOR & PREVAILING WAGE (LABOR & WAGES WILL BE
ADDED IF APPLICABLE), GAS VALVE INSTALLATION, ELECTRICAL HOOKUP AND
CONNECTIONS, HANGING OF FIRE CABINET, SHUNT TRIP, HANDHELD
EXTINGUISHER(S), ON-SITE RE-PIPING DUE TO EQUIPMENT LAYOUT CHANGES.
VOLTAGESIZE
TYPE
GAS VALVE SIZING GAS VALVE DIMENSIONS
DIM "A"DIM "B"DIM "C"DIM "D"DIM "F"DIM "G"
PART NUMBERS
GAS VALVES AND STRAINERS
INSTALLATION
MIN. INLET
PRESSURE
MAX. INLET
PRESSURE
FLOW AT 1 IN.W.C.
DROP NATURAL GAS
FLOW AT 1 IN.W.C.
DROP PROPANE
MOUNTING
ORIENTATION
GAS VALVE
PART NUMBER
STRAINER PART
NUMBER
GAS
VALVE/STRAINER KIT
ELECTRICAL
1-1/2"120 VAC 4417K6782142757-5/8"6-3/8"5-3/4"6-3/16"14-1/8"12-5/16"(SC)EGVA1-1/2GAS VALVE FOR FS#1
0 PSI
(0 IN.W.C.)
5 PSI
(138 IN.W.C.)
2,406,000 BTU/HR
1,561,219
BTU/HR
HORIZONTAL/
VERTICAL
FLOW.
ELECTRIC GAS VALVE.
STRAINER.
4" MIN.
DIM "G"
DIM "D"
DIM "A"
DIM "F"
DIM "C"
DIM "B"
ALL GAS VALVES/STRAINERS
TO CALCULATE GAS FLOW FOR OTHER THAN 1 IN.W.C. PRESSURE DROP
NEW BTU/HR = (BTU/HR AT 1 IN.W.C. PRESSURE DROP) X NEW PRESSURE DROP
0.5
TO CALCULATE GAS FLOW FOR OTHER THAN 0.64 SPECIFIC GRAVITY
NEW BTU/HR = (BTU/HR AT 0.64) X (0.64 / NEW SPECIFIC GRAVITY)
0.5
.
CALCULATIONS
PROPER CLEARANCE MUST BE PROVIDED IN ORDER TO SERVICE THE
STRAINERS A MINIMUM OF 4" CLEARANCE DISTANCE MUST BE
PROVIDED AT THE BASE OF THE STRAINER CUSTOMER MUST VERIFY
BTU CONSUMPTION AS WELL AS PRESSURE RATING SPECIFIC GRAVITY
OF NATURAL GAS = 0.64, SPECIFIC GRAVITY OF LP = 1.52.
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
C
U
S
6325918
MASTER DRAWING
SLS
4
12/8/2023
Mo
'
B
e
t
t
a
h
s
-
R
e
x
b
u
r
g
1/2" = 1'-0"
46
1
N
o
r
t
h
2
n
d
E
a
s
t
,
Ut
a
h
O
f
f
i
c
e
26
9
8
S
.
R
e
d
w
o
o
d
R
d
.
,
S
u
i
t
e
S
,
W
e
s
t
V
a
l
l
e
y
,
U
T
,
8
4
1
1
9
P
H
O
N
E
:
(
8
0
1
)
8
7
8
-
3
6
7
7
F
A
X
:
9
1
9
2
2
7
5
9
5
3
E
M
A
I
L
:
r
e
g
8
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
Re
x
b
u
r
g
,
I
D
,
8
3
4
4
0
EXHAUST FAN INFORMATION - JOB#6325918
1
2
1
1
DU180HFA
DU85HFA
CAPTIVEAIRE
CAPTIVEAIRE
3250
1356
1.708
1.081
1439
1310
ODP,PREMIUM
TEAO-ECM
3.000
1.000
1.9480
0.3730
3
1
208
208
9.5
6.9
751 FPM
429 FPM
202
99
23.8
10.7
FAN
UNIT
NO
TAG QTY FAN UNIT MODEL #MANUFACTURER CFM ESP RPM
MOTOR
ENCL
HP BHP PHASE VOLT FLA
DISCHARGE
VELOCITY
WEIGHT
(LBS)
SONES
MUA FAN INFORMATION - JOB#6325918
3 1 A2-D.500-20D 20MF-2-MOD A2-D.500 2000 3685 1.100 1790 ODP,PREMIUM 5.000 2.5940 3 208 15.0 20.9A 35A 5.22 90.0°F 61.0°F 71.0°F 61.0°F 985 20.1
FAN
UNIT
NO
TAG QTY FAN UNIT MODEL #BLOWER HOUSING
MIN
CFM
DESIGN
CFM
ESP RPM
MOTOR
ENCL
HP BHP PHASE VOLT FLA MCA MOCP
EVAP
FLOW RATE
(Gal/Hr)
EVAP COOLER
ENTERING DB
TEMP
EVAP COOLER
ENTERING WB
TEMP
EVAP COOLER
LEAVING DB
TEMP
EVAP COOLER
LEAVING WB
TEMP
WEIGHT
(LBS)
SONES
GAS FIRED MAKE-UP AIR UNIT(S)
3 287664 264651 81°F 7 IN. W.C. - 14 IN. W.C.NATURAL 92
FAN
UNIT
NO
TAG
INPUT
BTUs
OUTPUT
BTUs
TEMP RISE REQUIRED INPUT GAS PRESSURE GAS TYPE
BURNER
EFFICIENCY(%)
FAN OPTIONS
1
2
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
GREASE BOX
FAN BASE CERAMIC SEAL - SHIP LOOSE - FOR GREASE DUCTS
EXHAUST FAN HEAT BAFFLE
UNIT MOUNTED VFD FOR USE WITH ECPM03
VFD MOUNTING BRACKET FOR DU/DR 180 - 200
2 YEAR PARTS WARRANTY
GREASE BOX
FAN BASE CERAMIC SEAL - SHIP LOOSE - FOR GREASE DUCTS
ECM WIRING PACKAGE - PWM SIGNAL FROM ECPMO3 PREWIRE (TELCO MOTOR), CCW ROTATION
2 YEAR PARTS WARRANTY
SIZE 2 TEMPERED COMMERCIAL DOWN DISCHARGE FOR DIRECT DRIVE AHUS
INLET PRESSURE GAUGE, 0-35"
MANIFOLD PRESSURE GAUGE, -5 TO 15" WC
BUTTERFLY MOD VALVE OPTION FOR MOD SIZE 2 (1" MOD VALVE)
SHIP LOOSE GAS STRAINER 1"
MOTORIZED BACKDRAFT DAMPER FOR A2-D HOUSING - MEETS AMCA CLASS 1A RATING
CONTROL PANEL ENCLOSURE HEATER 100W - RECOMMENDED FOR WINTER DESIGN TEMPERATURES
LESS THAN 0°F
IBT/MUA EVAP INTERLOCK
FREEZE PROTECTION DRAIN KIT FOR EVAPORATIVE COOLERS
FREEZE PROTECTION DRAIN KIT FOR IBT/MUA WITH EVAPORATIVE COOLERS
SIZE 2 DIRECT FIRED HEATER LOW CFM PROFILE PACKAGE - USED ON HEATERS UNDER 2500
CFM
UNIT MOUNTED VFD FOR USE WITH ECPM03
2 YEAR PARTS WARRANTY
FAN
UNIT
NO
TAG QTY DESCRIPTION
FAN ACCESSORIES
1
2
3
YES
YES
YES
FAN
UNIT
NO
TAG
EXHAUST
GREASE
CUP
GRAVITY
DAMPER
WALL
MOUNT
SUPPLY
SIDE
DISCHARGE
GRAVITY
DAMPER
MOTORIZED
DAMPER
WALL
MOUNT
CURB ASSEMBLIES
1
2
3
# 1
# 2
# 3
# 3
52 LBS
41 LBS
90 LBS
CURB
CURB
CURB
RAIL
26.500"W X 26.500"L X 24.000"H VENTED HINGED.
23.000"W X 23.000"L X 24.000"H VENTED HINGED.
31.000"W X 79.000"L X 20.000"H INSULATED.
4.000"W X 4.000"L X 36.000"H.
NO
ON
FAN
WEIGHT ITEM SIZE
HMI SCHEDULE
UNIT NUMBER HMI #HMI LOCATION TEMP AVERAGING
MODBUS
ADDRESS
FAN #3 HMI #1 - UNIT HMI # 1 MOUNTED IN UNIT NOT AVERAGED 55
- VARIABLE SPEED CONTROL.
- THERMAL OVERLOAD PROTECTION (SINGLE PHASE).
- HIGH HEAT OPERATION 300°F (149°C).
EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING AIR AT 300°F (149°C)
UNTIL ALL FAN PARTS HAVE REACHED
THERMAL EQUILIBRIUM, AND WITHOUT ANY
DETERIORATING EFFECTS TO THE FAN WHICH
WOULD CAUSE UNSAFE OPERATION.
NORMAL TEMPERATURE TEST
26"
28"
37 3/8"
16 1/2"
2"
22 5/8"
- INTERNAL WIRING.
- ROOF MOUNTED FANS.
- RESTAURANT MODEL.
FEATURES:
- DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS).
TOP VIEW
37 3/8"
28"
- NEMA 3R SAFETY DISCONNECT SWITCH.
33 3/4"
GREASE DRAIN.
- GREASE CLASSIFICATION TESTING.
- UL705 AND UL762 AND ULC-S645
ABNORMAL FLARE-UP TEST
EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING BURNING GREASE VAPORS
AT 600°F (316°C) FOR A PERIOD OF
15 MINUTES WITHOUT THE FAN BECOMING
DAMAGED TO ANY EXTENT THAT COULD CAUSE
AN UNSAFE CONDITION.
26"
26"
ROOF OPENING
DIMENSIONS.
24"
26 1/2"
20 GAUGE
CONSTRUCTION.
STEEL
3" FLANGE.
26 1/2"
HINGE KIT
VENTED
CURB.
FAN #1 DU180HFA - EXHAUST FAN
OPTIONS
- GREASE BOX.
- FAN BASE CERAMIC SEAL - SHIP LOOSE
- FOR GREASE DUCTS.
- EXHAUST FAN HEAT BAFFLE.
- UNIT MOUNTED VFD FOR USE WITH
ECPM03.
- VFD MOUNTING BRACKET FOR DU/DR 180
- 200.
- 2 YEAR PARTS WARRANTY.
FAN BASE
ATTENTION: INSTALLER SHOULD SUPPLY
ENOUGH ELECTRICAL CORD TO LET FAN MAKE
FAN IN OPEN POSITION
PROVIDED TO OPERATE THE HOOD LIGHTS AND FANS.
A PRE-WIRED ELECTRICAL CONTROL PACKAGE SHALL BE
GREASE BOX INSTALLATION
CURB
ATTACH GREASE BOX COVER TO THE CURB 3" BELOW
USING (3) LONG (3/4" LG.) SCREWS AS SHOWN.
TOP EDGE OF CURB.
INSTALL GREASE PIPE AS SHOWN.
GREASE BOX
SEPARATOR
GREASE
BOX
COVER
ADDITIONAL FIRE SYSTEM ACTIVATED DRY CONTACTS.
DOUBLE-DUAL FIRE SYSTEM MICROSWITCH CONNECTION.
FOR SUPPLY FAN SHUTDOWN AND OTHER RELAY FOR
INPUT/OUTPUT TERMINAL STRIPS, AND A TERMINAL FOR
SUPPLIED BY THE ELECTRICAL CONTRACTOR.
OVERLOAD ASSEMBLY FOR EACH FAN(OPTIONAL), NUMBERED
SWITHCH(ES) AND RED-LIGHTED FAN SWITCH(ES), STARTER/
PACKAGE SHALL CONSIST OF SWITCH PANEL WITH LIGHT
BETWEEN THE PRE-WIRE PACKAGE AND FAN(S) SHALL BE
ONE RELAY IS WIRED TO MICROSWITCH (IN FIRE SYSTEM)
CONNECTED TO THE NUMBERED TERMINAL STRIP. CONDUIT
ELECTRICAL CONDUIT DROPS FROM THE FAN(S) SHALL BE
ELECTRICAL PACKAGE NOTES
4.
3.
1.
2.
GREASE PIPE
COMPLETE SWING.
HINGE KIT DETAIL
FAN IN CLOSED POSITION
GREASE BOX
(OPTIONAL)
GREASE PIPE
(OPTIONAL)
CURB
"A"
DETAIL
FAN
CURB
(LEFT)
PLATE
FAN BASE
PLATE
(LEFT)
FAN
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
C
U
S
6325918
MASTER DRAWING
SLS
5
12/8/2023
Mo
'
B
e
t
t
a
h
s
-
R
e
x
b
u
r
g
3/4" = 1'-0"
46
1
N
o
r
t
h
2
n
d
E
a
s
t
,
Ut
a
h
O
f
f
i
c
e
26
9
8
S
.
R
e
d
w
o
o
d
R
d
.
,
S
u
i
t
e
S
,
W
e
s
t
V
a
l
l
e
y
,
U
T
,
8
4
1
1
9
P
H
O
N
E
:
(
8
0
1
)
8
7
8
-
3
6
7
7
F
A
X
:
9
1
9
2
2
7
5
9
5
3
E
M
A
I
L
:
r
e
g
8
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
Re
x
b
u
r
g
,
I
D
,
8
3
4
4
0
- VARIABLE SPEED CONTROL.
- THERMAL OVERLOAD PROTECTION (SINGLE PHASE).
- HIGH HEAT OPERATION 300°F (149°C).
EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING AIR AT 300°F (149°C)
UNTIL ALL FAN PARTS HAVE REACHED
THERMAL EQUILIBRIUM, AND WITHOUT ANY
DETERIORATING EFFECTS TO THE FAN WHICH
WOULD CAUSE UNSAFE OPERATION.
NORMAL TEMPERATURE TEST
22 1/2"
24 3/4"
31 7/8"
14 7/8"
2"
23"
- INTERNAL WIRING.
- ROOF MOUNTED FANS.
- RESTAURANT MODEL.
FEATURES:
- DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS).
TOP VIEW
31 7/8"
24 3/4"
- NEMA 3R SAFETY DISCONNECT SWITCH.
30 1/2"
GREASE DRAIN.
- GREASE CLASSIFICATION TESTING.
- UL705 AND UL762 AND ULC-S645
ABNORMAL FLARE-UP TEST
EXHAUST FAN MUST OPERATE CONTINUOUSLY
WHILE EXHAUSTING BURNING GREASE VAPORS
AT 600°F (316°C) FOR A PERIOD OF
15 MINUTES WITHOUT THE FAN BECOMING
DAMAGED TO ANY EXTENT THAT COULD CAUSE
AN UNSAFE CONDITION.
22 1/2"
22 1/2"
ROOF OPENING
DIMENSIONS.
24"
23"
20 GAUGE
CONSTRUCTION.
STEEL
3" FLANGE.
23"
HINGE KIT
VENTED
CURB.
FAN #2 DU85HFA - EXHAUST FAN
OPTIONS
- GREASE BOX.
- FAN BASE CERAMIC SEAL - SHIP LOOSE
- FOR GREASE DUCTS.
- ECM WIRING PACKAGE - PWM SIGNAL
FROM ECPMO3 PREWIRE (TELCO MOTOR),
CCW ROTATION.
- 2 YEAR PARTS WARRANTY.
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
C
U
S
6325918
MASTER DRAWING
SLS
6
12/8/2023
Mo
'
B
e
t
t
a
h
s
-
R
e
x
b
u
r
g
3/4" = 1'-0"
46
1
N
o
r
t
h
2
n
d
E
a
s
t
,
Ut
a
h
O
f
f
i
c
e
26
9
8
S
.
R
e
d
w
o
o
d
R
d
.
,
S
u
i
t
e
S
,
W
e
s
t
V
a
l
l
e
y
,
U
T
,
8
4
1
1
9
P
H
O
N
E
:
(
8
0
1
)
8
7
8
-
3
6
7
7
F
A
X
:
9
1
9
2
2
7
5
9
5
3
E
M
A
I
L
:
r
e
g
8
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
Re
x
b
u
r
g
,
I
D
,
8
3
4
4
0
DIRECT FIRED (DF) PROFILE PLATE ASSEMBLY
DIRECT FIRED PROFILE PLATE SPECIFICATIONS:
DESCRIPTION:
DIRECT FIRED BURNERS SHALL HAVE PATENTED (US PATENT NO.: US6629523B2), SELF-ADJUSTING PROFILE
PLATES DESIGNED TO ENSURE PROPER AIR VELOCITY AND PRESSURE DROP ACROSS THE BURNER. PROFILE
APPLICATION:
SPRING-LOADED BURNER PROFILE PLATES ARE ENGINEERED TO AUTOMATICALLY REACT TO THE MOMENTUM OF
A FRESH AIR STREAM, WITHOUT THE NEED FOR ANY MOTORS OR ACTUATORS TO MECHANICALLY ADJUST THEM.
WITH THIS FEATURE, ALL DF UNITS ARE DESIGNED FOR DEMAND CONTROL VENTILATION (DCV) REQUIREMENTS.
CERTIFICATIONS:
ALL PROFILE PLATE ASSEMBLIES SHALL BE INCLUDED IN THE DF UNIT'S ETL LISTING AND COMPLY WITH COMBINED
SAFETY STANDARDS ANSI Z83.4 AND CSA 3.7 (NON-RECIRCULATING DF HEATERS) AND ANSI Z83.18
GENERAL CONSTRUCTION:
-PROFILE PLATES SHALL BE FORMED FROM G90 GALVANIZED STEEL.
-PROFILE PLATES SHALL VARY IN SIZE PER UNIT.
-PROFILE PLATES SHALL BE MOUNTED ALONG THE SAME PLANE AS THE DISCHARGE OF THE BURNER.
-DESIGN SHALL INCORPORATE PROPERLY TORQUED, PERMANENTLY MOUNTED SPRING HINGES.
PLATES SHALL ALLOW BURNERS TO ACHIEVE CLEAN COMBUSTION BY LIMITING BY-PRODUCT LEVELS TO A
MAXIMUM OF 5PPM OF CARBON MONOXIDE (CO), AND 0.5PPM OF NITROGEN DIOXIDE (NO2).
(RECIRCULATING DF HEATERS).
-SPRING HINGES SHALL BE MADE FROM PLATED STEEL.
DIRECT FIRED
UNITS SHALL BE CONFIGURED WITH THE BLOWER MOUNTED DOWNSTREAM OF THE BURNER. THIS ARRANGEMENT
WILL ENSURE A CONSISTENT AIRFLOW, REGARDLESS OF INLET AIR TEMPERATURE.
FLEX
CONDUIT
FOR FIELD
WIRING.
8 5/16"16"
6 1/8"
18 3/4"
LIFTING LUG.
3 3/4"
AIRFLOW.
BLOWER/MOTOR
ACCESS DOOR
24" SERVICE
CLEARANCE REQ.
79"
16 1/4"
SERVICE DISCONNECT
SWITCH.
AIRFLOW.
1" NPT.
7 13/16"
39 9/16"
DIRECT FIRED MODULE.
AIRFLOW.
20"
19"
∅1 1/2"
WATER
DRAIN.
AIRFLOW.
∅1/2" NPT
WATER INLET
WATER FILTER
REQUIRED PROVIDED
BY PLUMBER.
FILTER/CONTROL
ACCESS DOOR.
LPD CELDEK
AIRFLOW.
37 3/8"
16 1/4"
20"
31"
20" EQUIPMENT CURB.
CURB OUTER WALL.
DISCHARGE OPENING.
40 1/8"
36 3/4"
42 1/8"38 1/8"
ADJUSTABLE
LEG.
172"
MIN. 20"
MINIMUM
STRAIGHT
DUCT
PER AMCA*
FAN #3 A2-D.500-20D - HEATER
1. DIRECT GAS FIRED HEATED MAKE UP AIR UNIT WITH 20" MIXED FLOW DIRECT DRIVE FAN.
2. EVAP COOLER (LPD CELDEK) – W/INTAKE HOOD W/EZ FILTERS.
3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT.
4. DOWN DISCHARGE CONSTRUCTION FOR SIZE 2 DIRECT DRIVE AHUS.
5. GAS PRESSURE GAUGE, 0-35", 2.5" DIAMETER, 1/4" THREAD SIZE.
6. GAS PRESSURE GAUGE, -5 TO +15 INCHES WC., 2.5" DIAMETER, 1/4" THREAD SIZE.
7. BUTTERFLY MOD VALVE OPTION FOR MOD SIZE 2 (1" MOD VALVE).
8. SHIP LOOSE GAS STRAINER. TO BE INSTALLED UPSTREAM OF UNIT CONNECTION. 1" CONNECTION.
9. MOTORIZED BACK DRAFT DAMPER 22.75" X 24" FOR SIZE 2 STANDARD & MODULAR HEATER UNITS W/EXTENDED SHAFT, STANDARD
GALVANIZED CONSTRUCTION, 3/4" REAR FLANGE, LOW LEAKAGE, LF120S ACTUATOR INCLUDED.
10. CONTROL PANEL ENCLOSURE HEATER, INCLUDES 100W, 120V HEATER. RECOMMENDED FOR WINTER DESIGN TEMPERATURE LESS
THAN 0°F. OPERATES ON PCB CONTROLS IN IBT SINGLE MODULES OR RTU.
11. LAYER CONTROL FOR IBT EVAP.
12. FREEZE PROTECTION DRAIN CONTROL KIT FOR EVAPORATIVE COOLERS. INCLUDES 3-WAY WATER SOLENOID VALVE 8316G064
(SHIPPED LOOSE), PRESSURE SWITCH INSTALLED UPSTREAM OF 2WAY SOLENOID IN UNIT, BRASS TEE, 2 NPT HALF INCH NIPPLES,
AND TWO STAGE THERMOSTAT T678A1361. FIELD WIRING REQUIRED BY OTHERS FOR 3-WAY VALVE. FOR BOTH CELDEK AND
STANDARD V-BANK TYPE CONFIGURATIONS.
13. FREEZE PROTECTION DRAIN CONTROL KIT FOR EVAPORATIVE COOLERS. INCLUDES 3-WAY WATER SOLENOID VALVE 8316G064
(SHIPPED LOOSE), PRESSURE SWITCH INSTALLED UPSTREAM OF 2WAY SOLENOID IN UNIT, BRASS TEE AND 2 NPT HALF INCH
NIPPLES. FIELD WIRING REQUIRED BY OTHERS FOR 3-WAY VALVE. FOR BOTH CELDEK AND STANDARD V-BANK TYPE
CONFIGURATIONS.
14. PROFILE PLATE CONFIGURATION FOR SIZE 2 DIRECT FIRED UNIT FOR LOW CFM APPLICATIONS.
15. UNIT MOUNTED VFD FOR USE WITH ECPM03.
16. HINGED DOUBLE WALL INSULATED DOOR ASSEMBLY (BURNER/BLOWER/EVAP SECTION).
17. 2 YEAR PARTS WARRANTY.
*NOTE: SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS. A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED
DOWNSTREAM OF UNIT DISCHARGE AS OUTLINED IN AMCA PUBLICATION 201. WHEN USING RECTANGULAR DUCTWORK, ELBOWS MUST
BE RADIUS THROAT, RADIUS BACK WITH TURNING VANES. FLEXIBLE DUCTWORK AND SQUARE THROAT/SQUARE BACK ELBOWS SHOULD
NOT BE USED. ANY TRANSITION AND/OR TURNS IN THE DUCTWORK WILL CAUSE SYSTEM EFFECT. SYSTEM EFFECT WILL
DRASTICALLY INCREASE STATIC PRESSURE AND REDUCE AIRFLOW. DO NOT RELY ON UNIT TO SUPPORT DUCT IN ANY WAY. FAILURE
TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT.
SUGGESTED STRAIGHT DUCT SIZE IS 20" x 20".
SUPPLY SIDE HEATER INFORMATION:
WINTER TEMPERATURE = -2°F. TEMP. RISE = 81°F.
BTUs CALCULATED OFF ACTUAL AIR DENSITY.
OUTPUT BTUs AT ALTITUDE OF 0.0 FT. = 316516.
INPUT BTUs AT ALTITUDE OF 0.0 FT. = 344039.
OUTPUT BTUs AT ALTITUDE OF 4869 FT. = 264651.
INPUT BTUs AT ALTITUDE OF 4869 FT. = 287664.
L ETS
DI
R
ROOF OPENING 2" SMALLER THAN CURB DIMENSION.
2"
2"
3" FLANGE.
20 GAUGE
CONSTRUCTION.
STEEL
20"
31"
79"
OPTIONS:
- FULL BOTTOM CORNERS.
CURB.
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
C
U
S
6325918
MASTER DRAWING
SLS
7
12/8/2023
Mo
'
B
e
t
t
a
h
s
-
R
e
x
b
u
r
g
1/2" = 1'-0"
46
1
N
o
r
t
h
2
n
d
E
a
s
t
,
Ut
a
h
O
f
f
i
c
e
26
9
8
S
.
R
e
d
w
o
o
d
R
d
.
,
S
u
i
t
e
S
,
W
e
s
t
V
a
l
l
e
y
,
U
T
,
8
4
1
1
9
P
H
O
N
E
:
(
8
0
1
)
8
7
8
-
3
6
7
7
F
A
X
:
9
1
9
2
2
7
5
9
5
3
E
M
A
I
L
:
r
e
g
8
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
Re
x
b
u
r
g
,
I
D
,
8
3
4
4
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Label Description Location
MT-01 Fan Motor [3]
Component Identification
23
Installed Options
RD - RED
BL - BLUE
WH - WHITE
OR - ORANGE
BR - BROWN
BK - BLACK
PK - PINK
PR - PURPLE
GY - GRAY
GR - GREEN
YW - YELLOW
WIRE COLOR
DENOTES FIELD WIRING
DENOTES INTERNAL WIRING
NOTES
SW-01 Main disconnect switch [3]
BK
MT-01
GR
GR
BK
SW-01
5 6
3 4
1 2
BK
BK
L3
L2 V
W
L1 U
VFD
CAT 5
TO DCV
RJ45RJ45
EOL
>=15HP USE RS485
TO MODBUS CONVERTER
SW-01
BK
GR
GR
11
1
JUMPER
AND JUMPER 1,4,13A INSTEAD OF 1,11
EXHAUST 3.0HP-208V-3P-9.5FLA
VFD PART: ESV222N02YXB571
MOTOR INFO
ELECTRICAL INFORMATION
MOTOR/CTRL MCA: 11.9A
MOTOR/CTRL MOP: 20A
P107:
P108:
P410:
P150:
P100:
P194:
P103:
P167:
P102:
225
01
01
11
98
00
55.3
56.8
0.0
DRAWING NUMBER
JOB
MODELSHIP DATE
Exhaust Fan Wiring
EXH6325918-1
6325918 - Mo' Bettahs - Rexburg
12/8/2023 DU180HFA
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Label Description Location
MT-01 Fan Motor [3]
SW-01 Main disconnect switch [3]
Component Identification
23
Installed Options
RD - RED
BL - BLUE
WH - WHITE
OR - ORANGE
BR - BROWN
BK - BLACK
PK - PINK
PR - PURPLE
GY - GRAY
GR - GREEN
YW - YELLOW
WIRE COLOR
DENOTES FIELD WIRING
DENOTES INTERNAL WIRING
NOTES
SW-01
BK
MT-01
RD
GR
GR
RD
BK
3 4
1 2
WH
*22 AWG WHITE MOTOR
*22 AWG
ROTATION WIRE. CONNECT TO POWER
MOTOR
CONTROL
RD
YW
PWM
FROM
ECPMO3
RD
BK
LEG BLACK WIRE TO REVERSE ROTATION
GR
EXHAUST 1.0HP-208V-1P-6.9FLA
MOTOR INFO
ELECTRICAL INFORMATION
MOTOR/CTRL MCA: 8.7A
MOTOR/CTRL MOP: 15A
DRAWING NUMBER
JOB
MODELSHIP DATE
Exhaust Fan Wiring
EXH6325918-2
6325918 - Mo' Bettahs - Rexburg
12/8/2023 DU85HFA
A B C D E F G H I
1
2
3
4
5
6
7
8
9
10
COMPONENT LIST
LABEL DESCRIPTION
J1
J10 120V
J30 120V
J29 120V
J9 120V
10
1
J15
10
1
J35
123456789
101112131415161718
J7
1234567
891011121314
J13
1234567
891011121314
J18
SW-01
BK 1 2
3 4
TH
E
R
M
I
S
T
O
R
S
TH
E
R
M
I
S
T
O
R
S
4
5
A
3
2
7
6
S2
S1
RD
OR
WH
GY
BK
BR
YW
GR
BK
FR-01
FSC-01
TR-02
SPARK PLUG
N
BK
WH
J2 J3 J4 J5 J6
123456789
101112131415161718
123456789
101112131415161718
J31
123456789
101112131415161718
J36
123456789
101112131415161718
J32
VA-02
VA-01
BL
BR YW
LEGEND
FIELD WIRING
FACTORY WIRING
BK- BLACK
BL- BLUE
BR- BROWN
OR- ORANGE
WH- WHITE
OR/BL- OR/BL STRIPE
BL/RD- BL/RD STRIPE
RD/GN- RD/GN STRIPE
WH/BL- WH/BL STRIPE
YW- YELLOW
GY- GREY
PR- PURPLE
RD- RED
GR- GREEN
P
FL
W
D
OR
RD
BK
BR
BK
DM
BK
IEL
OR
WH
RD
BL
MT-01
GR
FIRE I/P TRIPS UPON 120VAC
BK
HE-01
WH
F
BK
N
2x
H
2x
8
AI-4DI-2
J28
1
AI-3AI-2
J14
1 8
AI-1DI-1
J12
1 8
C
R
BA
S
/
S
T
A
T
G
Y
W
J16
8
1
J11
8
1
NC C
SW-07
RD
H
VA-07
BK
WH
N
TP1(FSC-1)
TP
2
(
F
S
C
-
1
)
H
CB-01
N
SUPPLY
RD
BL
MT-05
120VAC O/P
120VAC I/P
SN-04
SN-03
SN-01
CNC
SW-08
OR
VA-08BK
WH
J33
VFD
T1
T2
T3
RJ45 RJ45
EOL
>=15HP USE RS485
TO MODBUS CONVERTER
L1
L2
L3
CAT 5
TO ECPM03
BK
BK 5 6
(CONVERTER MOUNTED IN MUA)
MODBUS
J38 3 1
BP
120V
BC
HMI
J2
208V
H N
BP
RD
BC
BL
BK WH
24V
(40VA)
120V
H
2
ON
1 3 4
MUA Board
2
ON
S2
1 1
ON
PROG
BP
S1*S3*
H
N
NOTES
* = S4 and S6
may be needed
for NFBUP-S.
J2
SPACE
HMI
BP
TR
-
0
1
LOCAL
HB
TR-05
GR
BK
RD
BL
WH
T1/L1 T2/L2
NOT REQ
IF SPACE
SENSOR IS
WIRED
ON
1 2 3 4 5 6 7 8
0-10VDC Output
RH SENSOR
BL-24VAC
GY-INTLK
SN-03
OR
IEL
N
A1A2
RE-DV
IEL/DEL
RD
YW
and IL1B in DCV
Wire to IL1A
NOC
RD
YW
RE-DV-1
D7
D3
GR
AL
HMI
J3
LOCAL
BK
WH
BK RD
TR-03
120
24
VA-05
WH BK
WH
HN
MOD-1 BK
123456789
101112131415161718
J8
Y(3)U(5)
C(1)+(2)
SUPPLY 5.0HP-208V-3P-15.0FLA
VFD PART: ESV402N02TXB571
MOTOR INFO
ELECTRICAL INFORMATION
MOTOR/CTRL CIRCUIT MCA: 20.9A
MOTOR/CTRL CIRCUIT MOP: 35A
P107:
P108:
P410:
P150:
P100:
P194:
P103:
P167:
P102:
225
01
01
21
90
00
75.0
76.4
0.0
DWG NO
JOB NO
DATE
DRAWN BY
JOB NAME
DESCRIPTION OF OPERATION
TYPE
DRAWING TITLE
MUA BOARD
(DETAILS TO
FOLLOW)
6325918
Mo' Bettahs - R...
FACTORY
AUTO
12/8/2023
HW6325918-3
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
HE-01 CABINET_HEATER
EVO/ECM-ACU+S1.1-MPFR-01
FIREYE_FLAME_SAFETYFSC-01
SUPPLY_MOTORMT-01
CIRCUIT_BREAKERCB-01
MT-05 INTAKE_DAMPER_MTR
DISCH/HIGH_LIMIT
OUTDOOR
INTAKE
SW-01 DISCONNECT_SWITCH
IGNITION_TRANSFMRTR-02
VA-07 EVAP_3_WAY_VALVE
MAIN_GAS_VALVEVA-02
CTRL_TRANSFMRTR-01
TEMP_SENSORSN-XX
EVAP_PRESS_SWITCHSW-07
EVAP_FLOAT_SWITCHSW-08
BOARD_POWER_TRFMRTR-05
VA-08 EVAP_VALVE
DCV_RELAYRE-DV B5/D1
B5
E5
B5
C5
I4/I5/I6/I7
B3
F7
C6
B9
A3
C4
B3
E3
B8
B8
B4
F7VA-01 PILOT_GAS_VALVE
OUTDOOR
VA-02 MAIN_GAS_VALVE
VA-01 PILOT_GAS_VALVE C7
C7
VA-05 MOD_GAS_VALVE E7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
WIRE COLOR
BK - BLACK
BL - BLUE
BR - BROWN
OR - ORANGE
RD - RED
WH - WHITE
YW - YELLOW
GR - GREEN
NOTES
DENOTES FIELD WIRING
DENOTES INTERNAL WIRING
GY - GRAY
Label Description Location
Component Identification
23
PR - PURPLE
PK - PINK
Installed Options
Pressure SwitchSW-07 [2][8]
To building
drain
Field Wired
and Piped
From building
water supply
Roof line
N
POINT-TO-POINT SUMMARY OF DRAIN CONNECTION
N
FL
P
W
D
H
EVAP COOLER TERMINALS
EQUIVALENT TERMINALS
LOCATED IN IBT
NC C
SW-07
C NC
SW-08
VA-08
VA-07
YW
RD
OR
BK
BK
WH
OR
WH
H
P
FL
W
D
Float SwitchSW-08 [2][9]
3 Way Drain ValveVA-07 [4][15]
Water SolenoidVA-08 [3][10]
Freeze Protection
DRAWING NUMBER
JOB
MODEL
SHIP DATE
Evaporative Cooler Wiring
IBTEC6325918-3
6325918 - Mo' Bettahs - Rexburg
12/8/2023 A2-D.500-20D
Power Connection
208/460/600 V 3 PH.
Gal-flex
conduit
(in unit)
BK
Disconnect
Switch
BK
Disconnect
Switch
120 V 1 PH.240 V 1 PH.
Customer
supplied
wiring
Factory
wiring
Disconnect
Switch
Installed Options
RD - RED
BL - BLUE
WH - WHITE
BK - BLACK
OR - ORANGE
BR - BROWN
PK - PINK
PR - PURPLE
GY - GRAY
GR - GREEN
YW - YELLOW
WIRE COLOR
NOTES
BK GR
Gal-flex
conduit
(in unit)
BK
Customer
supplied
wiring
Factory
wiring
RD GR
Gal-flex
conduit
(in unit)
BK
Customer
supplied
wiring
WH
Factory
wiring
GR WHRD
STANDING POWER
RD & WH Wire (115V, 1 PHASE)
See above details.
Cat 5
to DCV
FIELD WIRED CONTACTS
WHEN USED WITH PREWIRE
WIRE TO SFC1/SFO1
TO J16-5 & J16-6 ON MUA
TO D3 & D7
Field Wired Switch
SFC1
SFO1
BL
GY
D3
D7
DAMPER INTERLOCK
WIRE TO IL1A & IL1B
YW
RD
DRAWING NUMBER
JOB
MODEL
SHIP DATE
Installation Wiring
RP6325918-3
6325918 - Mo' Bettahs - Rexburg
12/8/2023 A2-D.500-20D
HMI SCHEDULE
UNIT NUMBER HMI #HMI LOCATION TEMP AVERAGING
MODBUS
ADDRESS
FAN #3 HMI #1 - UNIT HMI # 1 MOUNTED IN UNIT NOT AVERAGED 55
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
C
U
S
6325918
MASTER DRAWING
SLS
8
12/8/2023
Mo
'
B
e
t
t
a
h
s
-
R
e
x
b
u
r
g
3/4" = 1'-0"
46
1
N
o
r
t
h
2
n
d
E
a
s
t
,
Ut
a
h
O
f
f
i
c
e
26
9
8
S
.
R
e
d
w
o
o
d
R
d
.
,
S
u
i
t
e
S
,
W
e
s
t
V
a
l
l
e
y
,
U
T
,
8
4
1
1
9
P
H
O
N
E
:
(
8
0
1
)
8
7
8
-
3
6
7
7
F
A
X
:
9
1
9
2
2
7
5
9
5
3
E
M
A
I
L
:
r
e
g
8
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
Re
x
b
u
r
g
,
I
D
,
8
3
4
4
0
ELECTRICAL PACKAGE - JOB#6325918
1 DCV-2111 UTILITY CABINET RIGHT
UTILITY CABINET
RIGHT
HOOD # 2
1 LIGHT
1 FAN
SMART CONTROLS DCV
EXHAUST
EXHAUST
SUPPLY
3
1
3
3.000
1.000
5.000
208
208
208
9.5
6.9
15.0
NO TAG PACKAGE #LOCATION
SWITCHES
LOCATION QUANTITY
OPTION
FANS CONTROLLED
TYPE ɸ HP VOLT FLA
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
JOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
6325918
Mo' Bettahs - Rexburg
DCV-2111
12/8/2023
INSTALL
ECP #1-1
Demand Control Ventilation, w/ control for 2 Exhaust Fans, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fans
modulate based on duct temperature. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. Room temperature
sensor shipped loose for field installation.Verify distance between VFD and Motor; additional cost could apply if
distance exceeds 50 feet.
BREAKER PANEL TO PRIMARY CONTROL PANEL
Responsibility: Electrician
BREAKER PANEL PRIMARY CONTROL PANEL
BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED
BREAKER 1PH
CONTROL POWER. DO NOT WIRE
TO GFCI OR SHUNT TRIP
BREAKER.
Hot
Neutral
H1
N1
120 V
15 A
Ground
GND
1ST HOOD LIGHT BREAKER SHARED W/
CONTROL POWER. SWITCH #1
BREAKER PANEL TO FANS
Responsibility: Electrician
BREAKER PANEL FANS
POWER TO
REMOTE
WIRE DIRECTLY TO FAN DISCONNECT
BREAKER 3PH
MCA:
MOCP:
VFD
LINE
LINE
LINE
EXH-1
Ground
208V
11.9A
20A
SM-1
POWER TO
REMOTE
WIRE DIRECTLY TO FAN DISCONNECT
BREAKER 3PH
MCA:
MOCP:
VFD
LINE
LINE
LINE
SUP-3
Ground
208V
18.8A
30A
SM-2
BREAKER 1PH
MCA:
MOCP:
POWER TO
ECM FANS
LINE
LINE
208V
8.6A
EXH-2
Ground
15A
CONTROL PANEL TO FANS
Responsibility: Electrician
PRIMARY PANEL FANS
REMOVE EOL FROM THE LAST
COM LINK
MOUNTED VFD
MODBUS SLAVE CONNECTED TO J3
NETWORK AND WIRE IN THE
CAT-5 CABLE.
PLACE EOL IN EMPTY RJ-45.
CAT-5 CONNECTION.
EOL120A
TO J2 1
2
EXH-1
MB EX1
SM-1MB EX1
SHIELDED TWISTED PAIR
PWM
SPEED SIGNAL
CONTROL
PANEL TO
ECM
OUTDOOR RATED
FEED STP THROUGH INNER
COOLING TUBE. ALLOW FOR
ENOUGH SLACK ON STP FOR
PROPER HINGING. (EXHAUST ONLY)
NOTE: PWM SIGNAL IS POLARITY
SENSITIVE.
NIDEC MOTOR
TELCO MOTOR
BK TO GR
BK TO YW
RD TO RD
ZIEHL MOTOR
BK TO BK
P1A
P1B
EXH-2
ECM-01
FAN: 02
RED(+)
BLACK(-)
ECM-01
RED(+)
BLACK(-)
REMOVE EOL FROM THE LAST
MODBUS SLAVE CONNECTED TO J3
NETWORK AND WIRE IN THE
CAT-5 CABLE.
PLACE EOL IN EMPTY RJ-45.
CAT-5 CONNECTION.
EOL120ACOM LINK
MOUNTED VFD
TO
J3 1
2
SM-2
SUP-3
ECPM03
ECPM03
FAN START
SIGNAL
TO MUA BOARD
*WIRE TO UNIT
INTERLOCK
SFO1
SFC1
24VAC
24VAC
24V
UI*
SUP-3
MAKE UP AIR
PROVING
INTERLOCK
DAMPER
LOW VOLTAGE CONNECTION FOR
DAMPER INTERLOCK. WIRE
MULTIPLE SUPPLY ON THE SAME
ZONE IN SERIES. SHOULD
MUA ZONE 1
TERMINAL NAMES
DO NOT APPLY
IF MUA BY OTHERS
ON PCB
REMOVE JUMPER
HAVE CONTINUITY WHEN DAMPER
IS PROVEN OPEN.
NOT REQUIRED FOR ALL UNITS.
SEE MAKE-UP AIR SCHEMATIC.
IL1A
IL1B
D3
D7
CONTROL PANEL TO ACCESSORY ITEMS
Responsibility: Electrician
CONTROL PANEL COMPONENT
ALL SWITCHES FACTORY WIRED
CAT-5 CONNECTION
CONTROL PANEL
SWITCHES
TO
J4
CONTROL PANEL
HOOD LIGHTS
TO
1400 W MAX
WIRE TO J-BOX ON TOP OF HOOD
B1
W1
GND
BLACK
WHITE
GREEN
HOOD LIGHTS 1
WIRE TO CONTROL BOARD. INSTALL
SENSOR IN ROOM AWAY FROM HEAT
SOURCES. DO NOT INSTALL SENSOR
CONTROL PANEL
ROOM TEMP
TO
SENSOR
ON THE CEILING GRID, SEE MANUAL.
GROUPS:
T1A
T1B
ROOM TEMP
FACTORY WIRED TEMPERATURE
SENSOR. MOUNTED IN HOOD CAPTURE
CONTROL PANEL
CAPTURE VOLUME
TO
SENSOR VOLUME.
T2A
T2B
HOOD 2
CAPTURE 1
WIRE TO CONTROL BOARD.
SENSOR MOUNTED IN EXHAUST DUCT
CONTROL PANEL
DUCT SENSOR
TO
T3A
T3B
HOOD 1
RISER 1
CONTROL PANEL
GAS VALVE
TO
120V ONLY
ONLY ENERGIZED THROUGH LCD
HMI WHEN FIRE SYSTEM ARMED.
GAS
N1
HOT TO GAS VALVE
NEUTRAL
GAS SOLENOID
THE FOLLOWING CONNECTIONS
MAY OR MAY NOT BE
REQUIRED BASED ON JOBSITE
SPECIFICATIONS
CONTROL PANEL
EXTERNAL
SIGNAL FOR
SHUNT TRIP
ST TERMINAL IS ENERGIZED
IN FIRE CONDITION.
CONTROL PANEL
EXTERNAL
SIGNAL FOR
CONTACTOR COIL
KS TERMINAL IS DE-ENERGIZED
IN FIRE CONDITION.
ST
N1
NEUTRAL FROM SHUNT COIL
HOT TO SHUNT COIL
SHUNT COIL
KS
N1
NEUTRAL_TO_CONTACTOR_COIL
HOT_TO_CONTACTOR_COIL
CONTACTOR_COIL
SPARE CONTACTS WILL MAKE
CONTROL PANEL
ON/OFF WITH
DRY CONTACT
SUPPLY FAN
COMMON TO NORMALLY OPEN
WHEN SUPPLY FAN IS ON.
GROUP 1
SFC1
SFO1
COMMON
NORMALLY OPEN
SFC2
SFO2
COMMON
NORMALLY OPEN
WIRE TO ECPM03 TERMINALS.
CONFIGURABLE OUTPUT.
DCV SPEED
(TOTAL)
0-10V OUTPUT
ON PCB
SEE ECPM03 OWNERS MANUAL.
TO BMS
+
-
VO+
VO-
WIRE TO VFD TERMINAL STRIP.
PROPORTIONAL TO FREQUENCY.
VFD ANALOG
(EACH VFD)
0-10V OUTPUT
IN VFD
SEE VFD OWNERS MANUAL.
TO BMS
+
-
30
2
CONTROL PANEL
EXTERNAL
TO
SWITCH
SIGNAL SWITCH THROUGH BMS
WILL ACTIVATE ZONE1 FANS AND
LIGHTS
H1
IO1
BMS SWITCH
C NO
CONTROL PANEL
GAS VALVE
TO
24V DC ONLY
ONLY ENERGIZED THROUGH LCD
HMI WHEN FIRE SYSTEM ARMED.
(NOT NEEDED IF USING 120V
GAS VALVE).
LGV
N1D
POSITIVE TO GAS VALVE
NEGATIVE
GAS SOLENOID
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
JOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
6325918
Mo' Bettahs - Rexburg
DCV-2111
12/8/2023
INSTALL
ECP #1-2
Demand Control Ventilation, w/ control for 2 Exhaust Fans, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fans
modulate based on duct temperature. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. Room temperature
sensor shipped loose for field installation.Verify distance between VFD and Motor; additional cost could apply if
distance exceeds 50 feet.
CONTROL PANEL TO FIRE SYSTEM
Responsibility: ALARM CONTRACTOR
CONTROL PANEL COMPONENT
CONTROL PANEL
BUILDING
SIGNAL FOR
FIRE ALARM
PANEL
AL1
AL2
J9
BUILDING
ALARM PANEL
FIRE INPUT
WIRE DIRECTLY TO CORE CIRCUIT
BOARD. AL1 WILL MAKE AL2 IN FIRE
CONDITION.
CONTROL PANEL
BUILDING
SIGNAL FOR
TROUBLE
TROUBLE RELAY CONTACTS WILL
MAKE TBC TO TBL IN TROUBLE
CONDITION.
BUILDING
ALARM PANEL
ALARM
TBC
TBL
COMMON
NORMALLY CLOSED
CONTROL PANEL TO FIRE SYSTEM
Responsibility: CERTIFIED INSTALLER
CONTROL PANEL COMPONENT
FIRE STAT SUPERVISED LOOP
May be mixed factory and field
wiring. See Installation Schematic.
Multiple fire sensors possible.
HIGH TEMP WIRE (842 F), PN:
SLPCON-xFT required for all
Supervised Loop wiring in contact
with a hood. All other wiring shall
be PN: 6320UL, Belden or similar.
21
22
23
24
FS-01
BK WH
Fire Stat
FS-02
BK WH
Fire Stat
CONTROL PANEL
MOUNTED FIRE
TO DUCT
DETECTION
STAT(S)
FIRE STATS
CONTROL PANEL
SYSTEM PULL
TO FIRE
STATION
MANUAL ACTUATION LOOP / REMOTE FIRE
SYSTEM LOOP.
Multiple manual actuation possible.
Multiple manual actuation possible.
A Plug jumper with wires from pin1 to
pin4 and from pin2 to pin3 is mounted on
J10, remove the jumpers and
wire in the supervised actuation loop.
Microswitch MS-01 is optional for fire
system interlock.
Auxiliary Interlock (AUX-01):
Wire AU1 / AU2 of adjacent Master FS
panel(s) in each manual activation loop
for simultaneous activation. See Fire
system drawings for more information.
101
102
103
104
AUX-01
AU1 AU2
PULL STATION
MS-01
C NO
Micro SW
MAD-01
C NO
Manual
Actuation
Device
Adjacent
FS
Panel
CAT-5 CONNECTION
CONTROL PANEL
MASTER FS
TO
BOARD.
PLACE END OF LINE PLUG
EOL120A
IN EMPTY JACK. PN: EOL120A
CORE PCB
ADDITIONAL DEVICES MAY BE INLINE.
ECPM03
UNLESS VFD, PCU,
OR OTHER COMPONENT IN SERIES.
J3 J5
J6
CONTROL PANEL
MASTER FS
TO
PANEL
WIRE TO LIKE TERMINALS IN ALL
CORE PANELS THAT MUST ACTIVATE
TOGETHER. SET MASTER & SLAVE
DIP SWITCHES PER FIRE SYSTEM
SHIELDED TWISTED PAIR
INTERLOCK NETWORK MASTER CORE
MANUAL.
CA
CB
CC
BLACK
RED
SHIELD
CA
CB
CC
TANK PROTECTION ELECTRICAL DETAIL
02/10/2021 Rev. 2
ELECTRICIAN:
1. WIRE MAIN CONTROL PANEL PER INCLUDED SCHEMATIC
2. WIRE ALL FANS PER INCLUDED SCHEMATIC
3. WIRE SHUNT TRIP BREAKER (OPTIONAL)
4. WIRE UDS APPLIANCE KILL SWITCH, IF EQUIPPED (OPTIONAL)
5. WIRE GAS VALVE
NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS
EXHAUST HOOD
36 INCHES CLEARANCE REQUIRED IN FRONT
OF ALL UTILITY CABINET DOORS
THE PANEL SHALL ALSO BE LOCATED IN AN
ACCESSIBLE AREA WHERE THE AUDIBLE AND
VISUAL ALARMS CAN BE HEARD AND SEEN
GASELECTRIC
ELECTRICAL CONTRACTOR REQUIREMENT
ITEM CONNECTION IN PANEL CONNECTION IN DEVICE VOLTAGE AMPERAGE COMMENTS
SHUNT TRIP BREAKER (OPTIONAL)ST & N1
BREAKER COIL
(A1 & A2)
120 VAC < 4 AMPS ST TO A1 ON SHUNT BREAKER COIL, AND NEUTRAL TO A2 ON SHUNT TRIP BREAKER COIL
CONTROL PANEL POWER H1 & N1 + GROUND CIRCUIT BREAKER 120 VAC 15 AMPS CONTROL PANEL POWER MUST NOT BE RUN THROUGH SHUNT TRIP BREAKER
UDS APPLIANCE KILL SWITCH (OPTIONAL)KTS & N1 KTS & N1 120 VAC < 4 AMPS KILL SWITCH TERMINALS MUST BE IN SERIES WITH OTHER KILL SWITCHES
REMOTE 120VAC ANSUL AUTOMAN (OPTIONAL)AU1, AU2 SOLENOID 120 VAC < 6 AMPS 120V TO AU1, AU2 TO ANSUL ELECTRIC AUTOMAN, ANSUL SOLENOID TO NEUTRAL
GAS VALVE
LGV & N1D (IF 24 VDC)
GAS & N1 (IF 120 VAC)
RED/RED/GREEN
24 VDC
OR 120 VAC
< 1.0 AMPS
IF 24 VDC - 2 WIRES & GROUND, N1D TO RED, LGV TO RED, AND GREEN TO GROUND
IF 120 VAC - 2 WIRES & GROUND GAS TO RED, N1 TO RED, AND GREEN TO GROUND
SHUNT TRIP BREAKER (OPTIONAL)
-2 WIRES, 120VAC
-ST TO A1 ON SHUNT BREAKER
-NEUTRAL TO A2 ON SHUNT TRIP
BREAKER
POWER TO ELECTRIC
APPLIANCE
CONTROL PANEL POWER
-2 WIRES & GROUND
-120 VAC, 15 AMP SERVICE
-WIRE TO H1 AND N1, GROUND
-POWER MUST NOT ORIGINATE
FROM SHUNT TRIP BREAKER
GAS VALVE POWER
-2 WIRES & GROUND
-24 VDC WIRE TO LGV & N1D
-120 VAC WIRE TO GAS &N1
GAS VALVE
-STRAINER MUST BE
INSTALLED UPSTREAM
OF VALVE
COOKING
APPLIANCE(S)
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
JOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
6325918
Mo' Bettahs - Rexburg
DCV-2111
12/8/2023
INSTALL
ECP #1-3
Fire System #1 TANK FS - 4.0/4.0/4.0.
FS-1: MASTER
TANK PROTECTION LOW-VOLTAGE DETAIL
02/10/2021 Rev. 2
ALARM CONTRACTOR:
1. WIRE MANUAL ACTUATION DEVICE(S), REMOTE FIRESTAT(S), CORE INTERLOCK(S), FIRE SENSOR(S) AND FIRE ALARM CONTACTS
2. COMPLETE FINAL HOOKUP OF SYSTEM
3. VERIFY FINAL FIRE SYSTEM TEST
ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD
BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES
36 INCHES CLEARANCE REQUIRED IN FRONT
OF ALL UTILITY CABINET DOORS
THE PANEL SHALL ALSO BE LOCATED IN AN
ACCESSIBLE AREA WHERE THE AUDIBLE AND
VISUAL ALARMS CAN BE HEARD AND SEEN
EXHAUST HOOD
ELECTRIC
GAS
NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS
ALARM CONTRACTOR REQUIREMENT
ITEM CONNECTION IN PANEL CONNECTION ON DEVICE VOLTAGE AMPERAGE COMMENTS
MANUAL ACTUATION DEVICE(S)
101 AND 104
102 AND 103
1 & 2 24 VDC < 1.0 AMPS
WIRE MANUAL ACTUATION DEVICE TERMINAL 1 BETWEEN CORE PANEL TERMINALS 102 AND 103
WIRE MANUAL ACTUATION DEVICE TERMINAL 2 BETWEEN CORE PANEL TERMINALS 101 AND 104
JUMPER 101 TO 104 AND 102 TO 103 IF NO MANUAL ACTUATION DEVICE IS INSTALLED
MANUAL ACTUATION DEVICE COVER N/A N/A N/A N/A
MANUAL ACTUATION DEVICE COVER MUST BE INSTALLED
IF SURFACE MOUNTED, USE COVER EXTENSION STI-6531B
REMOTE FIRESTAT SENSOR(S)
21 AND 24
22 AND 23
BLACK AND WHITE 24 VDC < 1.0 AMPS
WIRE FIRE SENSOR WHITE WIRES BETWEEN HOOD CORE PANEL TERMINALS 22 AND 23
WIRE FIRE SENSOR BLACK WIRE BETWEEN HOOD CORE PANEL TERMINALS 21 AND 24
HIGH TEMP (842°F) #CW04427 (WHT) & #CW04427B (BLK)WIRE OR SIMILAR ONLY IF RAN OVER TOP
OF HOOD; OTHERWISE BELDEN #6320UL OR SIMILAR PLENUM RATED WIRE; SEE FIGURE 1
FIRE ALARM CONTACT AL1, AL2 VARIES
50V MAX
(AC/DC)
UP TO 1 AMP
FIRE ALARM RELAY CONTACTS FOR BUILDING FIRE ALARM LOCATED IN THE
CORE ELECTRICAL CONTROL PANEL
CORE INTERLOCK(S)ILA, ILB, ILC ILA, ILB, ILC
RS-485 COMMUNICATIONS
SIGNAL
CORE SYSTEM (1) ILA, TO CORE SYSTEM (2) ILA. CORE SYSTEM (1) ILB, TO CORE SYSTEM (2) ILB.
CORE SYSTEM (1) ILC, TO CORE SYSTEM (2) ILC. USE BELDEN# 88760 OR SIMILAR WIRE
TROUBLE CONTACT TBC, TBL, TOK VARIES MAX 120 VAC
UP TO 6
AMPS
WIRE TO TBL & TBC NORMALLY OPEN CONTACT, CLOSES IN TROUBLE CONDITION
CORE COMMUNICATIONS CABLE RJ-45 Jack INTERNET CONNECTION SIGNAL <1.0 AMPS
TYPICAL CONNECTION CAT5 CABLE TO LOCAL AREA NETWORK VIA ETHERNET SWITCH OR
WIRELESS ROUTER WITH VALID INTERNET CONNECTION
42 TO 48 INCHES
ABOVE FLOOR
LEVEL TO
CENTER OF PUSH
STATION
MANUAL
ACTUATION
DEVICE
10 TO 20
FEET FROM
HOOD LOCATED
NEAR POINT
OF EGRESS
FROM HOOD
MANUAL ACTUATION DEVICE WIRES
-4 WIRES, 24VDC WIRE (TERMINAL 1)
BETWEEN 102 AND 103
-WIRE (TERMINAL 2) BETWEEN 101 AND 104
-ADDITIONAL PULL STATIONS WIRED IN
SUPERVISED LOOP
-USE BELDEN #6320UL OR SIMILAR WIRE
-SEE FIGURE 2
MANUAL ACTUATION DEVICE
PART #STI-SS2431
PROTECTIVE COVER MUST BE INSTALLED
SUPERVISED LOOP
-4 WIRES, 24VDC CONNECT BLACK
WIRES BETWEEN 21 AND 24 IN PANEL,
CONNECT WHITE (OR RED) WIRES
BETWEEN 22 AND 23 IN PANEL
-ADDITIONAL FIRESTATS, WIRED IN
SUPERVISED LOOP
-USE HIGH TEMP (842°F) #CW04427
(WHT) & #CW04227B (BLK)WIRE ONLY
IF RAN OVER TOP OF HOOD;
OTHERWISE BELDEN #6320UL OR
SIMILAR PLENUM RATED WIRE
-SEE FIGURE 1
CORE COMMUNICATIONS CABLE
-CAT5 CABLE
MUST BE INSTALLED TO A LOCAL AREA
NETWORK WITH VALID INTERNET ACCESS
VIA ETHERNET SWITCH OR WIRELESS
ROUTER
CORE INTERLOCK
-2 WIRES + SHIELD
-USE BELDEN#88760 OR SIMILAR WIRE
-SEE FIGURE 3
FIRE ALARM PANEL
FIRE ALARM CONTACT
-2 WIRES WIRED TO NORMALLY
OPEN CONTACTS (CLOSES IN
FIRE CONDITION)
-CORE CONTROL PANEL AL1
AND AL2
-SEE FIGURE 2
TROUBLE CONTACT
-2 WIRES TO NORMALLY
OPEN CONTACTS (CLOSE
IN TROUBLE CONDITION)
-CORE PANEL TERMINALS
TBL AND TBC
-SEE FIGURE 4
COOKING
APPLIANCE(S)
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
JOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
6325918
Mo' Bettahs - Rexburg
DCV-2111
12/8/2023
INSTALL
ECP #1-4
Fire System #1 TANK FS - 4.0/4.0/4.0.
FS-1: MASTER
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
C
U
S
6325918
MASTER DRAWING
SLS
9
12/8/2023
Mo
'
B
e
t
t
a
h
s
-
R
e
x
b
u
r
g
3/4" = 1'-0"
46
1
N
o
r
t
h
2
n
d
E
a
s
t
,
Ut
a
h
O
f
f
i
c
e
26
9
8
S
.
R
e
d
w
o
o
d
R
d
.
,
S
u
i
t
e
S
,
W
e
s
t
V
a
l
l
e
y
,
U
T
,
8
4
1
1
9
P
H
O
N
E
:
(
8
0
1
)
8
7
8
-
3
6
7
7
F
A
X
:
9
1
9
2
2
7
5
9
5
3
E
M
A
I
L
:
r
e
g
8
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
Re
x
b
u
r
g
,
I
D
,
8
3
4
4
0
TANK PROTECTION LOW-VOLTAGE FIGURES
02/10/2021 Rev. 17
AL1
AL2 END
OF
LINE
DEVICE
WIRING CONNECTIONS FOR FIRE
ALARM CONTACT
FIGURE 2
CORE
CONTROL
PANEL
FIRE
ALARM
CONTACT
ALARM
INPUT
BUILDING
FIRE ALARM
SHIELDED TWISTED PAIR
ILA
ILC
ILB
ILA
BK
ILB
RD
BK
RD
WIRING CONNECTIONS
FOR CORE INTERLOCK
FIGURE 3
ILC
ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD
BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES
SUPERVISION
SWITCH
1 2
C
BUILDING
FIRE ALARM
TROUBLE
INPUT
CORE
CONTROL
PANEL
TROUBLE CONTACT
NO
C
NC 1
C
2
SUPERVISION
SWITCH
SUPERVISION
SWITCH
END
OF
LINE
DEVICE
TBC
TBLTOK
WIRING CONNECTIONS FOR
TROUBLE CONTACT
FIGURE 4
BK-C
BK-C
21
22
23
24
J2-1
J2-2
J2-4
J2-3
21
BK-C
101
102
103
104
J10-1
J10-2
J10-4
J10-3
21
BK-C
WIRING CONNECTIONS
FOR FIRESTAT LOOP
FIGURE 1
WIRING CONNECTIONS
FOR MANUAL ACTUATION LOOP
FIGURE 1A
BREAK WIRE
BEFORE
INSERTING
INTO
TERMINALS
FIRE
STAT-2
FIRE
STAT-1
NO-WH
(OR RD)
NO-WH
(OR RD)
BREAK WIRE
BEFORE
INSERTING
INTO
TERMINALS
NO-WH
(OR RD)
MANUAL
ACTUATION
DEVICE
NO-WH
(OR RD)
MANUAL
ACTUATION
DEVICE
MICROSWITCH/
NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS
USE BELDEN #6320UL
OR SIMILAR WIRE
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
JOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
6325918
Mo' Bettahs - Rexburg
DCV-2111
12/8/2023
INSTALL
ECP #1-5
Fire System #1 TANK FS - 4.0/4.0/4.0.
FS-1: MASTER
WH
BK
A B C D E F G H I
1
2
3
4
5
6
7
8
9
10
PANEL LID
COMPONENT LIST
LABEL DESCRIPTION
PN:
ST-X
varies
Starter
PN:
OL-X
varies
Overload
PN:
C-X
varies
Contactor
PN:
TS-x
A/CP-PO-T4"-EXPL
Duct Thermostat
120 VAC
RELAY
NO
COM
COIL
NC
34
6 5
8
2
7
1
RA-x
24 VDC
RELAY
RD-x
NO
COM
COIL
NC
34
6 5
8
2
7
1
PN:
PS-1
MDP18-24A-1C
Power Sup. 24VDC
BK
PN:
RA-x
34.110.0184.0
120V Relay DPDT
WH
PN:
RA-x
34.110.0184.0
120V Relay DPDT
GR
UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG.
N1
H1
DC
-
GN
D
DC
+
8H1
7PCU
6ST
5KS
4KTS
3GAS
2AR1
1N1
120VJ9
5OV1
4SF1
3EF1
2B1
1IO1
120VJ7
AR1
H1
2x
N1
2x
B1
EF1
SF1
BK
IO1
BK
BK
BK
JUMPER
W1
BK 14AWG BK
64
RD-1
BL PR
DC+RO1
PN:
RD-x
34.110.0188.0
24VDC Light Relay
BK WH
SF1 7 8RA-2
8 7RD-1
24V
1 2 3 4 5 6 7
8 9 10 11 12 13 14
J6
N1
ON/OFF
WITH
SUP
N1
RO
1
NH
FAN
PANEL COOLING
DRY CONTACTS (SHOWN DE-ENERGIZED)
HOOD LIGHTS
J3
ECPM03/DAISY CHAIN
AR1 H1
JUMPER FIRE SYSTEM
BK
BK
BK
GAS
KS
ST
NOTE: Configure ECPM03 for CORE
ECPM03
J10
IL
1
A
IL
1
B
JUMPER
MAKE UP AIR INTERLOCK.
NOTE: All items on ECPM03 J3 line to be daisy chained
from one component to the next, with EOL120A at end
of line. Place PN: EOL120A in empty RJ45 port.
J3
ECPM03 or Previous EOL
J5
MASTER CORE
C
RA-2-1
NO
SFC1
SFO1
14 AWG
YW
C
RA-2-2
NO
SFC2
SFO2
14 AWG
YW
FACTORY WIRING
SCHEMATIC
CIRCUIT BOARDS
ECPM03
SC-20 x 18 x 8.62 BOX
CONTROL INPUT 120V
H1=LINE, N1=NEUTRAL,
15A BREAKER. DO NOT
CONNECT TO SHUNT TRIP
BREAKER. SEE
INSTALLATION SCHEMATIC
FOR ADDITIONAL REQ.
NOTE: IF VFD HAS 1PH 240V INPUT, USE L1 & L2 ONLY.
IF VFD HAS 1PH 120V INPUT, USE L1 & N ONLY.
LEGEND
FIELD WIRING
FACTORY WIRING
BK- BLACK
BL- BLUE
BR- BROWN
OR- ORANGE
WH- WHITE
OR/BL- OR/BL STRIPE
BL/RD- BL/RD STRIPE
RD/GN- RD/GN STRIPE
WH/BL- WH/BL STRIPE
RD- RED
PR- PURPLE
GY- GREY
YW- YELLOW
WH
/
B
L
BL
H1N1
DC
-
DC
+
LN
-+
PS-01
AC
24V
GN
D
DC
KSKS
BK
KS
BK
BK
GAS
ST
P1
A
(
+
)
P1
B
(
-
)
58.2%
72.8%
BK
EF1
PR
WH
GR
/
Y
W
WH
/
B
L
BL
J4
A
MB EX1
BC
A B C
J1
J2
J3
J4
J5
J5
J5
ECPM03
NOTE: MODBUS EX BOARDS USED
FOR REMOTE MOUNTED VFD.
REFER TO INSTALL SCHEMATIC
FOR CONNECTIONS.
PN:
MB EX1
MODBUS-EX
Modbus Expansion
NH
FAN
SECONDARY PANEL COOLING IF NECESSARY
EF1
WHBK
JUMPER
ECPM03
J10
IL
2
A
IL
2
B
TERMINAL GAS USED FOR
120V POWERED GAS
VALVES ONLY
DWG NO
JOB NO
DATE
DRAWN BY
JOB NAME
DESCRIPTION OF OPERATION
TYPE
DRAWING TITLE
6325918
Mo' Bettahs - Re...
FACTORY
DCV-2111
12/8/2023
ECP #1-6
Demand Control
Ventilation, w/ control
for 2 Exhaust Fans, 1
Supply Fan, Exhaust on
in Fire, Lights out in
Fire, Fans modulate
based on duct
temperature. INVERTER
DUTY 3 PHASE MOTOR
REQUIRED FOR USE WITH
VFD. Room temperature
sensor shipped loose for
field installation.Verify
distance between VFD
and Motor; additional
cost could apply if
distance exceeds 50
feet.
A B C D E F G H I
1
2
3
4
5
6
7
8
9
10
MOTOR POWER CIRCUITS. SEE INSTALLATION
COMPONENT LIST
LABEL DESCRIPTION
PN:
ST-X
varies
Starter
120 VAC
RELAY
NO
COM
COIL
NC
34
6 5
8
2
7
1
RA-x
24 VDC
RELAY
RD-x
NO
COM
COIL
NC
34
6 5
8
2
7
1
FACTORY WIRING
SCHEMATIC
CIRCUIT BOARDS
ECPM03
DCV Rev. 2.10.00
HMI Rev. 2.10.00
SC-20 x 18 x 8.62 BOX
DIAGRAM FOR FIELD WIRING REQUIREMENTS.
PN:
C-X
varies
Contactor
PN:
SM-X
varies
VFD
LEGEND
FIELD WIRING
FACTORY WIRING
BK- BLACK
BL- BLUE
BR- BROWN
OR- ORANGE
WH- WHITE
OR/BL- OR/BL STRIPE
BL/RD- BL/RD STRIPE
RD/GN- RD/GN STRIPE
WH/BL- WH/BL STRIPE
RD- RED
PR- PURPLE
GY- GREY
YW- YELLOW
PN:
LR-X
varies
Line/Load Reactor
DWG NO
JOB NO
DATE
DRAWN BY
JOB NAME
DESCRIPTION OF OPERATION
TYPE
DRAWING TITLE
6325918
Mo' Bettahs - Re...
FACTORY
DCV-2111
12/8/2023
ECP #1-7
Demand Control
Ventilation, w/ control
for 2 Exhaust Fans, 1
Supply Fan, Exhaust on
in Fire, Lights out in
Fire, Fans modulate
based on duct
temperature. INVERTER
DUTY 3 PHASE MOTOR
REQUIRED FOR USE WITH
VFD. Room temperature
sensor shipped loose for
field installation.Verify
distance between VFD
and Motor; additional
cost could apply if
distance exceeds 50
feet.
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
U/T1
V/T2
W/T3
L1
L2
L3/N
GR
GR
GND
TO
MOTOR
VFD:
HP:
MTR:
FLA:
P107:
P108:
P410:
P150:
P100:
P194:
P101:
P131:
P167:
P103:
P102:
3 PH
20 A
208 V
SM-1
ESV222N02YXB571
225
01
01
11
98
00
9.5
3.000
EXH-1
N/A
N/A
56.8
55.3
0.0
GND
14 AWG
Mounted in Fan
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
U/T1
V/T2
W/T3
L1
L2
L3/N
GR
GR
GND
TO
MOTOR
VFD:
HP:
MTR:
FLA:
P107:
P108:
P410:
P150:
P100:
P194:
P101:
P131:
P167:
P103:
P102:
3 PH
30 A
208 V
SM-2
ESV402N02TXB571
225
01
01
21
90
00
15.0
5.000
SUP-3
N/A
N/A
76.4
75.0
0.0
GND
12 AWG
Mounted in Fan
A B C D E F G H I
1
2
3
4
5
6
7
8
9
10
FACTORY WIRING
SCHEMATIC
CORE FIRE
PROTECTION
COMPONENT LIST
LABEL DESCRIPTION
120 VAC
RELAY
NO
COM
COIL
NC
34
6 5
8
2
7
1
RA-x
24 VDC
RELAY
RD-x
NO
COM
COIL
NC
34
6 5
8
2
7
1
24 VOLT BATTERY PACK
5 AMP FUSE
RD
SHIELDED TWISTED PAIR
PCB-2
J3-2
J4-1
J3-11
J4-3
J4-2
J4-8
J4-9
J4-12
J3-14
J4-5
J3-13
J3-4
J4-6
J3-10
J2-1
J2-2
J2-3
J2-4
J7-2
J7-3
J7-1
J3-1 J3-3
RD
RD BR
RD
ALL 18AWG
RD BK
ORRD
PKRD
BRRD
RD OR/BL
BK 18AWG
BK
BK
J3-5
J1-1
J1-2
RD
BK
BK
RD
FIRE STAT SUPERVISED LOOP
May be mixed factory and field
wiring. See Installation Schematic.
Multiple fire sensors possible.
+
+
RD
BK
BK
RD
Shield
BK
RD
RS-485 CORE INTERLOCK
NETWORK. Connection to
other CORE Panels or
Communication Module. See
Installation Schematic for
Connection.
N1D 3xH1D3x
DISCONNECT J1
21
22
23
24
16AWG
WH
N1
H1
PN: 1606-XLP-60EQ
Adjust power supply to 27.5
Volts with an accurate
Digital Volt Meter or with an
HMI plugged into the CORE
board.
NL
+-
PS-02 60W
GR
BK
GND
PN:
PCB-2
PCBCORE-APP
CORE PCB
PN:
PS-02
1606-XLP-60E
CORE POWER SUPPLY
PN:
WS-x
varies
Water Solenoid
PN:
LT-06
PNL-1163-0UR
24V Red Ind. Light
PN:
LL-01
AQ5510
Surf. Level Sensor
PN:
AA-01
SCE120LA3FP1B
Audible Alarm
PN:
PB-XX
ZB4BA2/ZB4BZ1015
Prime/Reset Switch
PN:
SW-04
BZ-2RQ1-A2
Tamper Switch
PN:
SP-1
50000-805
Surfactant Pump
PB-01
Prime / Reset
A2A1
RD-20
Trouble Relay
A2A1
RD-17
Fire Relay
DRY CONTACTS (SHOWN DE-ENGERGIZED)
AA-01
Audible Alarm
SW-04
Door Tamper Switch
C NO
FS-01
BK WH
Fire Stat
FS-02
BK WH
Fire Stat
HIGH TEMP WIRE (842 F),
PN: SLPCON-xFT required
for all Supervised Loop
wiring in contact with a
hood. All other wiring
shall be PN: 6320UL,
Belden or similar. Factory
mounted hood sensors will
be terminated at junction
box on top of hood.
PN:
GV-1
varies
24v DC Gas Valve
INTERLOCK FOR AUTOMAN ACTIVATION.
Used for activating 120V automan
or adjacent Master CORE panels
during active Fire Condition.
11
RD-18-1
14
YW
J3-16
J3-8
LT-6
R
FIRE INDICATOR
DIP Switch
ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD
BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES.
RD/GNRD
A2A1
RD-19
Equipment Relay COOKING EQUIPMENT DISABLE RELAY.
For UDS Kill Switch, wire EKC and
EKS terminals to like terminals in
UDS panel.
12
11
RD-19-1
14
EKC
EST
EKS
YW
INTERLOCK FOR AUTOMAN ACTIVATION.
Used for activating 120V automan
or adjacent Master CORE panels
during active Fire Condition.
11
RD-18-1
14
YW
RD OR/BL
A2A1
RD-18
Auxiliary Interlock Relay
PN:
FS-XX
12-F28021-000360
Duct Fire Sensor
PN:
LT-05
PNL-1163-0UY
24V YLW Ind. Light
PN:
PS-01
Station STI-SS2431
Remote Puill/Push
FOR SHIPMENT
J10-1
J10-2
J10-3
J10-4
RD
BK
BK
RD
101
102
103
104
MANUAL ACTUATION LOOP / REMOTE FIRE
SYSTEM LOOP.
Multiple manual actuation possible.
A Plug jumper with wires from pin1 to
pin4 and from pin2 to pin3 should be
mounted on J10 if there is no manual
actuation device and no microswitch.
MAD-01
C NO
Manual
Actuation
Device
MS-01
C NO
Micro SW
1 2 3 4 5 6 7 8
SW
1
OPEN
PUT END OF LINE PLUG IN EMPTY RJ45
J3
ECPM03
UNLESS PCU AFM OR OTHER COMPONENT IN SERIES.
CAT-5 WIRING (MASTER ONLY)
FIELD WIRED IF REMOTE PREWIRE
PN:
RD-XX
PLC-RPT-24DC/21
24VDC Phoenix Relay
AUX-01
AU1 AU2
Auxiliary Interlock (AUX-01):
Wire AU1 / AU2 of adjacent Master CORE
panel(s) in each manual activation loop
for simultaneous activation.
AU1/AU2 will have continuity for 10
seconds if adjacent panel goes into fire
condition, activating this CORE Panel but
allowing for a reset after 10 seconds.
NOTE: AU1/AU2 terminals of CORE Panel
should not be wired into its own manual
activation loop.
Adjacent
CORE
Panel
Master CORE
set DIP SW 8
to CLOSED
position. Slave
CORE with
address 1 set
DIP SW 8 to
CLOSED
position. All
other CORES
set DIP SW 8
OPEN.
18AWG
LEGEND
FIELD WIRING
FACTORY WIRING
BK- BLACK
BL- BLUE
BR- BROWN
OR- ORANGE
WH- WHITE
OR/BL- OR/BL STRIPE
BL/RD- BL/RD STRIPE
RD/GN- RD/GN STRIPE
WH/BL- WH/BL STRIPE
YW- YELLOW
GY- GREY
PR- PURPLE
RD- RED
GR- GREEN
FIRE INDICATOR FAULT CONDITION FLASH CODES
2 Release Solenoid
3 Pressure Switch
4 Auxiliary Fault
5 Microcontroller Fault
6 N/A
7 Supervised Loop
8 Ground Fault
9 Surfactant Low
10 Battery Voltage Low
11 AC Power Failure
12 Door Tamper Switch
13 Test Mode
14 CORE Interlock Network
15 Fault on Hood in Interlock Network
16 Fault on PCU in Interlock Network
FIRE ALARM SYSTEM DRY CONTACTS.
Termials AL1 & AL2 make in FIRE.
To Building Fire
Alarm Panel
J9
AL1
AL2
J3-7
FIRE SYSTEM DRY CONTACTS.
Dry contacts will make C2 to AR2
when system is armed.
12
11
RD-17-1
C2
AR2
14 AWG
YW
TROUBLE RELAY. Contact terminals
TBC & TBL make if there is trouble.
Contact terminals TBC & TOK make if
the system is ok.
12
11
RD-20-1
14
TBC
TBL
TOK
YW
RD
PS
OR
J4-9
PN:
PS
EWC-PRESSURE
Pressure Switch
PR
RS
SW-05-1
Test Armed
3 4
YW
RS-1
RELEASE SOLENOID
BLBR
RD OR
SW-05-3
Test Armed
3 4 J4-13
PN:
SW-05
ZB5AD2
TEST/ARM Switch
RS2
PR
SW-05-2
Test Armed
3 4
YW
PS-1
Pressure Switch
WH
14
PN:
PWS-01
24VDC 18W POWER
24VDC Power Suppl
CA
CB
CC
AU1AU1
AU2AU2
TR2
PN:
MAD-01
DEVICE
MANUAL ACTIVATION
GAS VALVES SHOULD BE WIRED
TO MASTER CORE BOARD ONLY.
RDRD
GV-1
24V DC Gas Valve
LGV
PK TERMINAL LGV USED FOR 24VDC
POWERED GAS VALVES ONLY.
(2nd Contact)
DWG NO
JOB NO
DATE
DRAWN BY
JOB NAME
DESCRIPTION OF OPERATION
TYPE
DRAWING TITLE
6325918
Mo' Bettahs - Re...
FACTORY
DCV-2111
12/8/2023
ECP #1-8
Fire System #1 TANK FS
- 4.0/4.0/4.0.
FS-1: MASTER
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
C
U
S
6325918
MASTER DRAWING
SLS
10
12/8/2023
Mo
'
B
e
t
t
a
h
s
-
R
e
x
b
u
r
g
3/4" = 1'-0"
46
1
N
o
r
t
h
2
n
d
E
a
s
t
,
Ut
a
h
O
f
f
i
c
e
26
9
8
S
.
R
e
d
w
o
o
d
R
d
.
,
S
u
i
t
e
S
,
W
e
s
t
V
a
l
l
e
y
,
U
T
,
8
4
1
1
9
P
H
O
N
E
:
(
8
0
1
)
8
7
8
-
3
6
7
7
F
A
X
:
9
1
9
2
2
7
5
9
5
3
E
M
A
I
L
:
r
e
g
8
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
Re
x
b
u
r
g
,
I
D
,
8
3
4
4
0
TYPICAL HOOD CONTROL PANEL INSTALLATION
CONTROL PANEL.
LCD
INTERFACE.
DUCT TEMPERATURE SENSOR.
ROOM TEMPERATURE
SENSOR.
DEMAND CONTROL VENTILATION HOOD CONTROL PANEL SPECIFICATIONS:
-CONTROLS SHALL BE LISTED BY ETL (UL 508A) AND SHALL COMPLY WITH DEMAND VENTILATION SYSTEM
TURNDOWN REQUIREMENTS OUTLINED IN IECC 403.7.5 (2021).
-THE CONTROL ENCLOSURE SHALL BE NEMA 1 RATED AND LISTED FOR INSTALLATION INSIDE OF THE
EXHAUST HOOD UTILITY CABINET. THE CONTROL ENCLOSURE MAY BE CONSTRUCTED OF STAINLESS STEEL
OR PAINTED STEEL.
-TEMPERATURE PROBE(S) LOCATED IN THE EXHAUST DUCT RISER(S) SHALL BE CONSTRUCTED OF
STAINLESS STEEL.
-A DIGITAL CONTROLLER SHALL BE PROVIDED TO ACTIVATE THE HOOD EXHAUST FANS DYNAMICALLY BASED
ON A FIXED DIFFERENTIAL BETWEEN THE AMBIENT AND DUCT TEMPERATURES SENSORS. THIS FUNCTION
SHALL MEET THE REQUIREMENTS OF IMC 507.1.1.
-A DIGITAL CONTROLLER SHALL PROVIDE ADJUSTABLE HYSTERESIS SETTINGS TO PREVENT CYCLING OF THE
FANS AFTER THE COOKING APPLIANCES HAVE BEEN TURNED OFF AND/OR THE HEAT IN THE EXHAUST
SYSTEM IS REDUCED.
-A DIGITAL CONTROLLER SHALL PROVIDE AN ADJUSTABLE MINIMUM FAN RUN-TIME SETTING TO PREVENT FAN
CYCLING.
-VARIABLE FREQUENCY DRIVES (VFDS) SHALL BE PROVIDED FOR FANS AS REQUIRED. THE DIGITAL
CONTROLLER SHALL MODULATE THE VFDS BETWEEN A MINIMUM SETPOINT AND A MAXIMUM SETPOINT ON
DEMAND. THE DUCT TEMPERATURE SENSOR INPUT(S) TO THE DIGITAL CONTROLLER SHALL BE USED TO
CALCULATE THE SPEED REFERENCE SIGNAL.
-THE VFD SPEED RANGE OF OPERATION SHALL BE FROM 0% TO 100% FOR THE SYSTEM, WITH THE ACTUAL
MINIMUM SPEED SET AS REQUIRED TO MEET MINIMUM VENTILATION REQUIREMENTS.
-AN INTERNAL ALGORITHM TO THE DIGITAL CONTROLLER SHALL MODULATE SUPPLY FAN VFD SPEED
PROPORTIONAL TO ALL EXHAUST FANS THAT ARE LOCATED IN THE SAME FAN GROUP AS THE SUPPLY FAN.
-THE SYSTEM SHALL OPERATE IN PREP MODE DURING LIGHT COOKING LOAD OR COOL DOWN MODE WHEN
SUFFICIENT HEAT REMAINS UNDERNEATH THE HOOD SYSTEM AFTER COOKING OPERATIONS HAVE
COMPLETED. OPERATION DURING EITHER OF THESE PERIODS WILL DISABLE THE SUPPLY FANS AND PROVIDE
AN EXHAUST FAN SPEED THAT IS EQUAL TO THE MINIMUM VENTILATION REQUIREMENT.
-A DIGITAL CONTROLLER SHALL DISABLE THE SUPPLY FAN(S), ACTIVATE THE EXHAUST FAN(S), ACTIVATE
THE APPLIANCE SHUNT TRIP, AND DISABLE AN ELECTRIC GAS VALVE AUTOMATICALLY WHEN FIRE CONDITION
IS DETECTED ON A COVERED HOOD.
-A DIGITAL CONTROLLER SHALL ALLOW FOR EXTERNAL BMS FAN CONTROL VIA DRY CONTACT (EXTERNAL
CONTROL SHALL NOT OVERRIDE FAN OPERATION LOGIC AS REQUIRED BY CODE).
-AN LCD INTERFACE SHALL BE PROVIDED WITH THE FOLLOWING FEATURES:
A. ON/OFF PUSH BUTTON FAN & LIGHT SWITCH ACTIVATION.
B. INTEGRATED GAS VALVE RESET FOR ELECTRONIC GAS VALVES (NO RESET RELAY REQUIRED).
C. VFD FAULT DISPLAY WITH AUDIBLE & VISUAL ALARM NOTIFICATION.
D. DUCT TEMPERATURE SENSOR FAILURE DETECTION WITH AUDIBLE & VISUAL ALARM NOTIFICATION.
E. MIS-WIRED DUCT TEMPERATURE SENSOR DETECTION WITH AUDIBLE & VISUAL ALARM NOTIFICATION.
F. A SINGLE LOW VOLTAGE CAT-5 RJ45 WIRING CONNECTION.
G. AN ENERGY SAVINGS INDICATOR THAT UTILIZES MEASURED KWH FROM THE VFDS.
SEQUENCE OF OPERATIONS:
THE HOOD CONTROL PANEL IS CAPABLE OF OPERATING IN ONE OR MORE OF THE FOLLOWING STATES AT ANY
GIVEN TIME:
-AUTOMATIC: THE SYSTEM OPERATES BASED ON THE DIFFERENTIAL BETWEEN ROOM TEMPERATURE AND
THE TEMPERATURE AT THE HOOD CAVITY OR EXHAUST DUCT COLLAR. FANS ACTIVATE AT A
CONFIGURABLE TEMPERATURE DIFFERENTIAL THRESHOLD. DEPENDING ON THE JOB CONFIGURATION EACH FAN
ZONE CAN BE CONFIGURED AS STATIC OR DYNAMIC. THESE TERMS REFER TO WHETHER A VARIABLE
MOTOR (SUCH AS EC MOTORS OR VFD DRIVEN MOTORS) MODULATE WITH TEMPERATURE. IF THE PANEL IS
EQUIPPED WITH VARIABLE SPEED FANS AND THE ZONE IS DEFINED AS "DYNAMIC", THESE WILL MODULATE
WITHIN A USER-DEFINED RANGE BASED ON THE TEMPERATURE DIFFERENTIAL. PANELS EQUIPPED WITH
VARIABLE SPEED FANS AND A FAN ZONE DEFINED AS "STATIC", FANS WILL RUN AT A SET SPEED
CALCULATED FOR THE DRIVE. DEMAND CONTROL VENTILATION SYSTEMS ARE CAPABLE OF MODULATING
EXHAUST AND MAKE UP AIR FAN SPEEDS PER THE REQUIREMENTS OUTLINED IN IECC 403.7.5 (2021).
-MANUAL: THE SYSTEM OPERATES BASED ON HUMAN INPUT FROM AN HMI.
-SCHEDULE: A WEEKLY SCHEDULE CAN BE SET TO RUN FANS FOR A SPECIFIED PERIOD THROUGHOUT THE
DAY. THERE ARE THREE OCCUPIED TIMES PER DAY TO ALLOW FOR THE USER TO SET UP A TIME THAT IS
SUITABLE TO THEIR NEEDS. ANY TIME THAT IS WITHIN THE DEFINED OCCUPIED TIME, THE SYSTEM WILL RUN
AT MODULATION MODE AND FOLLOW THE FAN PROCEDURE ALGORITHM BASED ON TEMPERATURE DURING THIS
TIME. DURING UNOCCUPIED TIME, THE SYSTEM WILL HAVE AN EXTRA OFFSET TO PREVENT UNINTENDED
ACTIVATION OF THE SYSTEM DURING A TIME WHERE THE SYSTEM IS NOT BEING OCCUPIED.
-OTHER: THE SYSTEM OPERATES BASED ON THE INPUT FROM AN EXTERNAL SOURCE (DDC, BMS OR
HARD-WIRED INTERLOCK).
FIRE:UPON ACTIVATION OF THE HOOD FIRE SUPPRESSION SYSTEM, THE EXHAUST FAN WILL COME ON OR
CONTINUE TO TO RUN, THE HOOD MAKEUP AIR WILL SHUTDOWN, AND A SIGNAL WILL BE SENT FOR
ACTIVATING THE SHUNT TRIP BREAKER PROVIDED BY THE ELECTRICIAN. FUEL GAS WILL SHUT OFF VIA A
MECHANICAL/ELECTRICAL GAS VALVE ACTUATED BY THE HOOD FIRE SUPPRESSION SYSTEM.
-
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION
ww
w
.
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
DATE:
AC
C
O
R
D
A
N
C
E
No
.
9
6
BU
I
L
T
NF
P
A
WI
T
H
IN
S
LI
D
TE
R
C
U
S
6325918
MASTER DRAWING
SLS
11
12/8/2023
Mo
'
B
e
t
t
a
h
s
-
R
e
x
b
u
r
g
3/4" = 1'-0"
46
1
N
o
r
t
h
2
n
d
E
a
s
t
,
Ut
a
h
O
f
f
i
c
e
26
9
8
S
.
R
e
d
w
o
o
d
R
d
.
,
S
u
i
t
e
S
,
W
e
s
t
V
a
l
l
e
y
,
U
T
,
8
4
1
1
9
P
H
O
N
E
:
(
8
0
1
)
8
7
8
-
3
6
7
7
F
A
X
:
9
1
9
2
2
7
5
9
5
3
E
M
A
I
L
:
r
e
g
8
7
@
c
a
p
t
i
v
e
a
i
r
e
.
c
o
m
Re
x
b
u
r
g
,
I
D
,
8
3
4
4
0