Loading...
HomeMy WebLinkAboutAPPROVED PLANS - 21-00753 - 832 Oak Hill Cir - New SFRAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Tawnya Grover Tawnya.Grover@rexburg.org 208-372-2167 Alan Parkinson Alan.Parkinson@rexburg.org 208-372-2165 Description : 832 Oak Hill Cir - New SFR Address : Record Type : New Single Family Residence Document Filename : DeLaCruz 8 Sept 2021.PDF Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 21-00753 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments 1 - TITLE / NOTES Stamp Larry Beesley : Building Open 1 Approved - Building Inspector 2 - MAIN FLOOR PLAN Free text Larry Beesley : Building Open 2 x 2 - MAIN FLOOR PLAN Free text Larry Beesley : Building Open 2 HOLD DOWNS 2 - MAIN FLOOR PLAN Ellipse Larry Beesley : Building Open 2 2 - MAIN FLOOR PLAN Line Larry Beesley : Building Open 2 2 - MAIN FLOOR PLAN Free text Larry Beesley : Building Open 2 3' 2 - MAIN FLOOR PLAN Stamp Larry Beesley : Building Open 2 Approved - Building Inspector 3 - BASEMENT FLOOR PLAN Free text Larry Beesley : Building Open 3 x New Single Family Residence Approval of plans does not constitute approval of variance from code Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments 3 - BASEMENT FLOOR PLAN Free text Larry Beesley : Building Open 3 x 3 - BASEMENT FLOOR PLAN Free text Larry Beesley : Building Open 3 x 3 - BASEMENT FLOOR PLAN Free text Larry Beesley : Building Open 3 x 3 - BASEMENT FLOOR PLAN Free text Larry Beesley : Building Open 3 x 3 - BASEMENT FLOOR PLAN Free text Larry Beesley : Building Open 3 x 3 - BASEMENT FLOOR PLAN Free text Larry Beesley : Building Open 3 4200 LB HOLD DOWNS 3 - BASEMENT FLOOR PLAN Line Larry Beesley : Building Open 3 3 - BASEMENT FLOOR PLAN Line Larry Beesley : Building Open 3 3 - BASEMENT FLOOR PLAN Line Larry Beesley : Building Open 3 3 - BASEMENT FLOOR PLAN Free text Larry Beesley : Building Open 3 x 3 - BASEMENT FLOOR PLAN Free text Larry Beesley : Building Open 3 1800 Lb Hold Down 3 - BASEMENT FLOOR PLAN Line Larry Beesley : Building Open 3 3 - BASEMENT FLOOR PLAN Free text Larry Beesley : Building Open 3 3' 3 - BASEMENT FLOOR PLAN Line Larry Beesley : Building Open 3 3 - BASEMENT FLOOR PLAN Line Larry Beesley : Building Open 3 3 - BASEMENT FLOOR PLAN Free text Larry Beesley : Building Open 3 S 3 - BASEMENT FLOOR PLAN Free text Larry Beesley : Building Open 3 Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12" Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6" 3 - BASEMENT FLOOR PLAN Stamp Larry Beesley : Building Open 3 Approved - Building Inspector 4 - SECTION AND DETAILS Free text Larry Beesley : Building Open 4 3"x3" Approval of plans does not constitute approval of variance from code Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments 4 - SECTION AND DETAILS Line Larry Beesley : Building Open 4 4 - SECTION AND DETAILS Free text Larry Beesley : Building Open 4 x 4 - SECTION AND DETAILS Rectangle Larry Beesley : Building Open 4 4 - SECTION AND DETAILS Free text Larry Beesley : Building Open 4 You must follow the 2018 IRC energy code requirements. 4 - SECTION AND DETAILS Line Larry Beesley : Building Open 4 4 - SECTION AND DETAILS Stamp Larry Beesley : Building Open 4 Approved - Building Inspector 5 - ELEVATION Free text Larry Beesley : Building Open 5 Street Number Displayed on House 5 - ELEVATION Free text Larry Beesley : Building Open 5 Roof Ventilation as per R806 5 - ELEVATION Free text Larry Beesley : Building Open 5 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) 5 - ELEVATION Free text Larry Beesley : Building Open 5 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. 5 - ELEVATION Free text Larry Beesley : Building Open 5 Minimum Frost Depth Ground Surface to Bottom of Footing 36" 5 - ELEVATION Stamp Larry Beesley : Building Open 5 Approved - Building Inspector 6 - ELEVATION Free text Larry Beesley : Building Open 6 Roof Ventilation as per R806 6 - ELEVATION Free text Larry Beesley : Building Open 6 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) 6 - ELEVATION Stamp Larry Beesley : Building Open 6 Approved - Building Inspector 1 - TITLE / NOTES Stamp Tawnya Grover : P&Z Open 1 Plan Received 1 - TITLE / NOTES Stamp Alan Parkinson : P&Z Open 1 Corrections Required C1 - SITE PLAN Stamp Alan Parkinson : P&Z Open 7 Corrections Required C1 - SITE PLAN Callout Alan Parkinson : P&Z Open 7 Need to draw in sidewalks and ADA Ramp for corner Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) The plans are the joint property of B'n'R Drafting and the Client. They are not to be reproduced or to be used for any construction except by express written consent by one of the owning parties. B'n'R Drafting assumes no liability beyond the production of these plans. All information contained has been exclusively provided by the client and are accepted as is. Th e s e p l a n s h a v e b e e n p r e p a r e d b y a n A D D A C e r t i f i e d D r a f t e r t o a p p r o v e d dr a f t i n g p r a c t i c e s . A l l i n f o r m a t i o n c o n t a i n e d i n t he s e p l a n s h a v e b e e n pr o v i d e d b y t h e c u s t o m e r a n d h a s b e e n a c c e p t e d a s i s. B ' n ' R D r a f t i n g Se r v i c e s h a s h a d n o i n v o l v e m e n t i n t h e C i v i l , S t r u c tu r a l , M e c h a n i c a l o r El e c t r i c a l E n g i n e e r i n g f o r t h i s p r o j e c t u n l e s s e x p l ic i t l y n o t e d . B ' n ' R D r a f t i n g Se r v i c e s w i l l n o t p e r f o r m a n y s e r v i c e s r e s e r v e d f o r a n A r c h i t e c t o r E n g i n e e r . Al l L i a b i l i t y f o r t h i s p r o j e c t r e m a i n s s o l e l y w i t h th e c o n t r a c t o r , s u b c o n t r a c t o r s an d O w n e r . F i n a l P l a n s a r e a c c e p t e d A S I S . 1993 N. 37th E Idaho Falls, Idaho 83401 208-589-8383 DATE: DRAWN BY: PROJECT: FOR ofB'n'R DraftingServices LLCRRS 8 Sept 2021 2104059 Saul & Cindy DeLaCruz 6 SINGLE FAMILY DWELLING TITLE / NOTES 1 - - - - - - - - - - - - - - - - - - New Residence Cindy & Saul DeLaCruz A3SH T A1 A2 MA I N F L O O R P L A N BA S E M E N T F L O O R P L A N DE S C R I P T I O N SH E E T I N D E X TI T L E P A G E / F R O N T E L E V A T I O N A4 A5 A6SH T SE C T I O N / D E T A I L S FR O N T / R E A R E L E V A T I O N S RI G H T / L E F T S I D E E L E V A T I O N S DE S C R I P T I O N SQUARE FOOTAGE Rexburg, IDAHO Basement 1805 SF Main Floor 1805 SF 3610 SF Garage 558 SF Total Area The included text is provided for the contractor's convenience. All text as found in the IRC-2018 codes shall override any text within these plans if there is a conflict. Any notation included with these drawings that are provided by an Architect or Structural Engineer, shall take priority over any text printed within these drawings. KITCHEN - 100 CFM Intermittent or 25 CFM Continuous BATHROOMS - Mechanical Exhaust Capacity 50 CFM Intermittent or 20 CFM Continuous If Natural Ventilation is Less Than 5 air changes per hr Then A Whole-House Mechanical Ventilation System Capable of Supplying Outdoor Air of 15 Cubic Ft Per Minute Per Occupant. Contractor and/or Electrical Sub- Contractor to indicate exact location of fan units if not already indicated on the plan set. MINIMUM EXHAUST RATES (M1505) CONTRACTORS NOTES Unless noted otherwise the following header list Shall be used. Headers 4' or Less = (1) 1 3/4" x 9 1/2" LVL or (2) 2x10 Dim. Lumber Headers 6' or Less = (2) 1 3/4" x 9 1/2" LVL Headers 8' or Less = (3) 1 3/4" x 9 1/2" LVL or (2) 1 3/4" x 9 1/2" LVL Headers 10' or Less = (3) 1 3/4" x 11 7/8" LVL or (2) 1 3/4" x 14" LVL BASED ON 35 psf LOAD HEADER TABLE: DRAWN BY B'N'R DRAFTING SERVICES DRAWN BY B'N'R DRAFTING SERVICES 1/2" or 25/32" Thick Structural Wood Sheathing applies Vertically or Horizontally on Studs Spaced a Maximum of 16" o.c. 4'-0" MINIMUM 8d Common Nails @ 6" o.c. Edge and 12" o.c. Intermediate - IRC 2018 Table R602.3 (1) EXTERIOR WALL BRACE PANEL 1/2" Thick Gypsum Board applies on Studs Spaced a Maximum of 24" o.c. 4'-0" MINIMUM 1 1/2" galvanized roofing nail, 6d common nail staple galvanized 1/2" long, 1 1/4" screws type W or S @ 7" o.c. @ 4" o.c. Edge and 8" o.c. Intermediate - IRC 2018 Table R602.3(1) INTERIOR WALL BRACE PANEL 3" C L R 10"x24" Sq Concrete Ftg W/(3) #4 E.W. (Contractor to verify footing size and loading prior to construction) UNDISTURBED SOIL 12" Dia Concrete Pier W/(6) #4 Vert Rebar to Secure Concrete Pier to Concrete Ftg 2x10 Treated Ledger Board Secured to Structure Structure 2x10 Treated Rim Board Secured to Post System 2x10 Treated Deck Joists @ 16" o.c. (to be verified by contractor) w/ 2x Treated Decking over 2x10 Treated Deck Joist Rafter Wood Beam 4x4 Post with Simpson Post Cap & Post Stirrup (or Equal) POST AND BEAM SYSTEM A) Secondary Span Support if req'd to be spec. By contractor B) Deck Railing System if present shall meet current building codes for vert and horiz Loading. C) Contractor to verify with owner prior to construction location of all deck locations, if any. Contractor to provide details on aspects of any included deck system, and location of required bearing system. Above is provided as "TYPICAL" construction. DRAWN BY B'N'R DRAFTING SERVICES DRAWN BY B'N'R DRAFTING SERVICES 34 " - 3 8 " 36 " M i n Gu a r d R a i l t o b e p r o v i d e d a t p o r c h e s , b a l c o n i e s o r r a i s e d f l o o r l o c a t e d m o r e t h a n 3 0 " a b o v e f l o o r o r g r a d e w i t h i n 3 6 " H o r z . Guard Rail shall have Intermediated rails or ornamental closures that do not allow passage of a sphere 4" in diameter. Triangle opening formed by the raiser, tread and bottom rail shall be such that a sphere 6" dia cannot pass through. Max riser height is 7 3/4" with a max of 3/8" variation during continuous run. Min tread width is 10" with a max of 3/8" variation during continuous run. Handrails shall be provided on at least one side of each continuous run with 4 or more risers. Handgrip portion shall have a circular cross section of 1 1/4" - 2" or equivalent Handgrip edges shall have a Min. rad of .01" STAIR HANDRAILS If under-stair is enclosed and accessible the walls soffits shall be protected on the enclosed side with 1/2" gypsum board S 1. All Dimensions for Exterior Walls are Measured from Inside of Sheathing. 2. Unless Otherwise Specified All Dimensions Are Measured from finished wall. (assuming 1/2" gyp) 3. Unless Otherwise Specified All Angles Are 45 Degrees 4. Unless Otherwise Specified All Exterior Walls Are to be 2x6. 5. Unless Otherwise Specified All Basement Walls Are to be 8" Concrete. 6. Unless Otherwise Specified All Window Headers Are to be at Approx 6'-8" Above Floor. NOTES: SMOKE DETECTOR Contractor to verify all site dimensions and location prior to construction to ensure that all information within this plan set conforms to existing conditions, and to ensure compliance of local codes and ordinances as it pertains to the site location. 1 Contractor to verify all beam/header sizes have been properly determined to match loading for the area in which this structure is to be built. Refer to Engineered Roof Truss Layout, and Engineered Floor Joist Layout for information regarding structurally loading data used to design this structure. (Note: These plans do not provide this data as it is provided by the distributors of the respective Roof Truss / Floor Joist Suppliers) 2 Contractor to locate and supply information in regards to all foundation vents on all crawlspaces. 3 Contractor to verify with local codes for all Design Requirements with Asphalt Emulsion on Exterior Side over Concrete Footing Systems. 4 Contractor to verify with local codes for all Design Requirements over Undisturbed Soil. 5 Contractor to verify prior to construction all footing sizes, load requirements, soil bearing data, and SE requirements. 6 Contractor to verify with owner prior to construction all exterior materials, colors and types. 7 Contractor to verify all location of solid surfaces that require foundation adjustments. 8 Contractor to provide information on all areas requiring glazing with safety materials. 9 Contractor to verify all exterior siding systems that owner may specify. Contractor is responsible for all material details regarding products specifications, installation, and engineering data that may be required by owner or building department when obtaining permits. 10 Typically, B'n'R Drafting Services does not provide Electrical, HVAC, or Plumbing notes, layouts, etc. Contractor is responsible for these. NOTE: All Stairs shall be Provided Illumination (R303.7) Wall switch @ each interior level where stairway has 6 or more risers. (R303.8) Exterior stairways shall provide light @ top landing. Ext stairs to basement shall provide light @ the bottom. GENERAL NOTES The following information are for code compliance. Any Local Codes, Specification by an Engineer or Architect supersede this information. Floor Framing by Others U.N.O. Roof Framing by Others U.N.O. Minimum Specified Compressive Strength of Concrete (IRC 2018 Table R402.2) Bsmnt walls, fnd and other concrete not exposed to to the weather 2,500 psf Bsmnt walls, fnd and other concrete exposed to to the weather 3,000 psf Porches, carport slabs and steps exposed to the weather and garage floor slabs 3,500 psf BRACE WALL PANEL DETAIL Overlapped Double Plate 2x6 Exterior Wall @ 16" o.c. with 7/16" Waferboard Drywall & Waferboard not shown for Clarity 2x4 Interior Wall @ 16" o.c. Nailing or Screws 7" o.c. Max, Horz & Vert 4'x8' Shear Paneling on Both Sides or 8'x8' Shear Paneling on Single Side Blocks at Drywall Joint for 7" o.c. Screws or Nails Dryall is Shown Cutaway 4 8 " 4 8 " 48 1 / 2 " t o C e n t e r CCARBON MONOXIDE ALARM Flashing 1/2" dia Bolt or Lag per Table R507.2 Building shall have approved address numbers. The numbers shall be contrasted with their background. Numbers shall be 4" high, min stroke width of 1/2", arabic or alphabetical letters in a visible area. 11 CARBON MONOXIDE ALARM (R315) If not already indicated on plans, Contractor and/or Electrical Subcontractor shall indicate on plans the location of all carbon monoxide alarms. In a dwelling unit containing a fuel-fired appliance and/or an attached garage a Carbon Monoxide alarms are required outside each sleeping area. Where a fuel- fired appliance is located within the bedroom a Carbon Monoxide alarem shall be installed within the bedroom. 10 ' -0" M a x Wall=Lngth 8'=16" 9'=18" 10'=20" For Frames Over 8' PanelSplace (If Needed) Shall Occur Within 24" of Mid-Height. Blocking is Required. If 2x Blocking is Used Then it Must Be Stitch Nailed With One Row of 16d Sinkers @ 3" o.c. Fasten Sheathing To HeaderWith 8d Common Nails in 3' Grid Pattern as Shown and 3" o.c. in All Framing (studs and Sills) Typ. 1000 LB Header Strap Opposite Sheathing as Shown (See Section A-A Typ Fasten Top Plate To Header With Two Rows of 16d Sinkers @ 3" o.c. Typ (2) 1/2" Dia Anchor Bolts With 7" Min Embedment and 2"x2"x3/16" Plate Washer DBL 2x Post 2x Framing Typical Portal Frame Construction 6' TO 18' 3"x11.25" Min. Header (Built-Up, Solid Sawn, Glulam, Etc) SINGLE PORTAL FRAME DOUBLE PORTAL FRAME 7/16" Min Thickness Wood Structural Panel 16d Sinkers 2 Rows @ 3" o.c. 1000 LB Header Strap (On Opposite Side of Sheathing Sheathing Filler If Needed SECTION A-A SIDE ELEVATIONFRONT ELEVATION NOT TO SCALE CS-PF (fig R602.10.6.4) DRAWN BY B'N'R DRAFTING SERVICES Fasten Sheathing to Header With 8d Common or Galv Box Nails in a 3" Grid Pattern as Shown Provide a minimum of 30" of working space in front of the furnace and a minimum of 3" along the sides and back. Any furnace located in the garage is required to be protected from impact. The ignition source shall be elevated 18". The maximum length of a clothes dryer exhaust vent is 35'. A reduction in the maximum length of 2.5' for each 45 degrees, and 5.0 for every 90 degree bend shall apply. or per manuf instructions. All 120-volt branch circuits for 15 & 20 amp receptacle outlets in dwelling rooms, bedrooms, closets, halls and similar areas shall be protected by an arc-fault circuit interrupter. 10 An Ice Barrier Consisting of at least two layers underlayment cemented together or of a self-adhering polymer modified bitumen sheet, shall be used in lieu of Normal Underlayment and Extend from the lowest edges of all roof surfaces to a point at least 24" inside the Exterior Wall Line of the Building (R905.1.2) 11 The Garage shall be Separated from the Residence and its Attic Area by not less than 1/2" Gypsum Board Applied to the Garage Side. Garage beneath habitable rooms shall be separated by not less that 5/8" type X Gypsum board or equivalent. (R302.6) 1 2 3 A 22" x 30" attic space access point is req'd. R807 Unless specified, the Contractor is to locate it. 4 A 18" x 24" crawl space access point is req'd if a crawlspace exists. R408.4 Unless specified the Contractor is to locate it. 5 Provide floor and/or landing on each side of exterior doors. The width of the landing shall not be less than the width of the stairway or door served. Minimum of 36" in the direction of travel is required. Exception:Non-Egress Door w/ no more than 2 risers, provided the door swings in. (R311.3.2) 6 7 8 Flashing shall be Installed in such a Manner so as to Prevent Moisture Entering the Wall and Roof Through Joints in Copings, Through Moisture Permeable Materials, and other Penetrations through the Roof Plane. (R903.2) 9 12 13 Where Ceramic Tile is used Cement, Fiber-Cement or Glass Mat Gypsum Backer in Compliance with Code and Installed in Accordance with Mfg Recommendations Shall Be used as Backer for Wall Tile in Tub and Shower Areas and Wall Panel in Shower Area. (R702.4.2) All Basement Sleeping Room's Window Wells a Greater than 44" Vertical Depth Shall have a Permantly Affixed Ladder or Steps. R310.2.3.1 Openings between the Garage and the Residence shall be either: a Solid Wood Door no less than 1 3/8" thickness, A Solid or Honeycomb-Core Steel Doornot less than 1 3/8" Thick, or a 20-Min Fire-Rated Door. Equipped With a Self-Closing Device R302.5.1 Patio Covers are not to exceed 12' in height. (This is not mandatory unless specifically Refer in the Adopting ordinance. (AH104.1) SMOKE ALARM (R314) If not already indicated on plans, Contractor and/or Electrical Subcontractor shall indicate on plans the location of all smoke alarms. Smoke alarms are required in each sleeping room, outside each sleeping area, and on each level or story of the structure. All smoke alarms to be interconnected such that the actuation of one alarms will actuate all alarms. Smoke alarms are required to be wired to the primary power source and have battery backup. Smoke alarms Shall be Installed no less that 3ft Horz from the door or opening of the a bathroom that contains a bathtub or shower unless this would prevent placement of a smake alarm Note: Location on plans are approximate REV DATE DESCRIPTION RE F . DW UP 18'x8' 4068 4068 3068 3068 2668 5050 4050 3030 3068 3068 2068 3068 3068 4050 3068SL 2650 5050 8' - 2"4' - 2"4' - 0"5' - 2"5' - 2"5' - 0"5' - 0"3' - 6"8' - 6"12' - 0" 16' - 4"10' - 4"10' - 0"24' - 0" 5' - 0 " 5' - 0 " 3' - 0 " 9' - 4 " 2' - 1 0 " 5' - 0 " 12 ' - 6 " 10 ' - 0 " 32 ' - 8 " 14' - 0"2' - 3"7' - 8"2' - 1"7' - 6"8' - 0"8' - 0"7' - 6" 26' - 0"31' - 0"3' - 8" 2' - 0 " 7' - 6 " 16 ' - 6 " 12 ' - 0 " 7' - 4 " 3' - 1 1 " 12 ' - 4 " 5' - 5 " 67 ' - 0 " 30 ' - 4 " 2' - 0 " Master Suite 15'-10" x 14'-4" Bedroom 11'-10" x 11'-7" Bedroom 10'-0" x 11'-5" Family Room 18'-0" x 19'-6" Nook 12'-0" x 10'-6" 2 Car Garage 23'-4" x 21'-7" E E S S S S 9' - 2" 2' - 4 1/2" 2' - 0"6' - 10" 6' - 0 " 2' - 0 " 3' - 4 1/2" 2050 2050 29 ' - 0 " 36 ' - 0 " 2' - 0 " 4050 3068 3' - 0 " 4' - 5 " 3' - 7 " 2668 2668 3068 60' - 8" 9'x8' 7' - 0"10' - 0"7' - 0" 24' - 0" 3' - 6"3' - 6"5' - 0"5' - 0"3' - 6"3' - 6" 2650 5' - 0 " 0' - 8 " 6068 3030 Bench w/ Hooks C 40504050 20' - 0 1/2" 6' - 2 " 3' - 3 " 5' - 9 " 3' - 3 " 1' - 9 " 6' - 0 " 6' - 6 " 8' - 5" 6' - 9"3' - 6" 4' - 0 " 3' - 5" The plans are the joint property of B'n'R Drafting and the Client. They are not to be reproduced or to be used for any construction except by express written consent by one of the owning parties. B'n'R Drafting assumes no liability beyond the production of these plans. All information contained has been exclusively provided by the client and are accepted as is. Th e s e p l a n s h a v e b e e n p r e p a r e d b y a n A D D A C e r t i f i e d D r a f t e r t o a p p r o v e d dr a f t i n g p r a c t i c e s . A l l i n f o r m a t i o n c o n t a i n e d i n t he s e p l a n s h a v e b e e n pr o v i d e d b y t h e c u s t o m e r a n d h a s b e e n a c c e p t e d a s i s. B ' n ' R D r a f t i n g Se r v i c e s h a s h a d n o i n v o l v e m e n t i n t h e C i v i l , S t r u c tu r a l , M e c h a n i c a l o r El e c t r i c a l E n g i n e e r i n g f o r t h i s p r o j e c t u n l e s s e x p l ic i t l y n o t e d . B ' n ' R D r a f t i n g Se r v i c e s w i l l n o t p e r f o r m a n y s e r v i c e s r e s e r v e d f o r a n A r c h i t e c t o r E n g i n e e r . Al l L i a b i l i t y f o r t h i s p r o j e c t r e m a i n s s o l e l y w i t h th e c o n t r a c t o r , s u b c o n t r a c t o r s an d O w n e r . F i n a l P l a n s a r e a c c e p t e d A S I S . 1993 N. 37th E Idaho Falls, Idaho 83401 208-589-8383 DATE: DRAWN BY: PROJECT: FOR ofB'n'R DraftingServices LLCRRS 8 Sept 2021 2104059 Saul & Cindy DeLaCruz 6 SINGLE FAMILY DWELLING MAIN FLOOR PLAN 2 - - - - - - - - - - - - - - - 1/4" = 1'-0"1 MAIN FLOOR REV DATE DESCRIPTION x HOLD DOWNS 3' UP Concrete Slab Contoured To Allow for Adequate Drainage 2668 27 ' - 8 " 3068 3068 3068 5068 506840683068 Family Room 29'-0" x18'-0" Mech Room 8'-7" x 7'-8" Bedroom 14'-2" x 13'-3" Bedroom 14'-4" x 12'-1"Storage 10'-0" X 10'-0" Play Zone 7'-2" x 4'-0" Open Railing Beam 4040 4040 4040 4040 26' - 0"31' - 0"3' - 8" 7' - 0"24' - 0" 10 ' - 0 " 7' - 2 " 7' - 5 1 / 4 " 10 ' - 1 1 / 2 " 7' - 1 1 1 / 4 " 32 ' - 8 " 16' - 9" 9' - 11"10' - 0" 7' - 0"10' - 0"7' - 0" 24' - 0" 20' - 4" 6' - 0 " 2' - 0 " 35 ' - 4 " 2' - 0 " 2' - 1 0 1 / 2 " 9' - 3 " 2' - 9 " 18 ' - 3 " 2' - 1 0 1 / 2 " 13 ' - 6 " 15 ' - 6 " 29 ' - 0 " 38 ' - 0 " 67 ' - 0 " 17' - 2"13' - 10" 13 ' - 6 " 2' - 0 " 2' - 9 " 8' - 1 1 " 5' - 6 " E E S S S Beam 15' - 1 1/2"10' - 6" 9' - 3" 60' - 8" 60' - 8" 12 ' - 2 " 5' - 0 " 2' - 0 " 2' - 2 " 2' - 0 " C 14' - 0 1/4"5' - 7 3/4" The plans are the joint property of B'n'R Drafting and the Client. They are not to be reproduced or to be used for any construction except by express written consent by one of the owning parties. B'n'R Drafting assumes no liability beyond the production of these plans. All information contained has been exclusively provided by the client and are accepted as is. Th e s e p l a n s h a v e b e e n p r e p a r e d b y a n A D D A C e r t i f i e d D r a f t e r t o a p p r o v e d dr a f t i n g p r a c t i c e s . A l l i n f o r m a t i o n c o n t a i n e d i n t he s e p l a n s h a v e b e e n pr o v i d e d b y t h e c u s t o m e r a n d h a s b e e n a c c e p t e d a s i s. B ' n ' R D r a f t i n g Se r v i c e s h a s h a d n o i n v o l v e m e n t i n t h e C i v i l , S t r u c tu r a l , M e c h a n i c a l o r El e c t r i c a l E n g i n e e r i n g f o r t h i s p r o j e c t u n l e s s e x p l ic i t l y n o t e d . B ' n ' R D r a f t i n g Se r v i c e s w i l l n o t p e r f o r m a n y s e r v i c e s r e s e r v e d f o r a n A r c h i t e c t o r E n g i n e e r . Al l L i a b i l i t y f o r t h i s p r o j e c t r e m a i n s s o l e l y w i t h th e c o n t r a c t o r , s u b c o n t r a c t o r s an d O w n e r . F i n a l P l a n s a r e a c c e p t e d A S I S . 1993 N. 37th E Idaho Falls, Idaho 83401 208-589-8383 DATE: DRAWN BY: PROJECT: FOR ofB'n'R DraftingServices LLCRRS 8 Sept 2021 2104059 Saul & Cindy DeLaCruz 6 SINGLE FAMILY DWELLING BASEMENT FLOOR PLAN 3 - - - - - - - - - - - - - - - WINDOW SCHEDULE Tag Qty Width Height Frame Pane Low-E U-Factor Sill Height Description 2050 2 2' - 0" 5' - 0" VINYL DBL YES .32 1' - 8" 2650 2 2' - 6" 5' - 0" VINYL DBL YES .32 1' - 8" 3030 2 3' - 0" 3' - 0" VINYL DBL YES .32 3' - 8" 4040 4 4' - 0" 4' - 0" VINYL DBL YES .32 2' - 8" 4050 5 4' - 0" 5' - 0" VINYL DBL YES .32 1' - 8" 5050 2 5' - 0" 5' - 0" VINYL DBL YES .32 1' - 8" 1/4" = 1'-0"1 BASEMENT FTG Door Schedule Type Qty Width Height Frame Glazing U-Factor DESCRIPTION 9'x8' 1 9' - 0" 8' - 0" Wood <50% .33 18'x8' 1 18' - 0" 8' - 0" Wood <50% .33 2068 1 2' - 0" 6' - 8" Wood NA NA 2668 1 2' - 6" 6' - 8" Wood NA NA 2668 3 2' - 6" 6' - 8" Wood NA NA 3068 1 3' - 0" 6' - 8" Wood NA NA 3068 9 3' - 0" 6' - 8" Wood <varies> <varies> 3068 2 3' - 0" 6' - 8" Wood NA NA 3068SL 1 3' - 0" 6' - 8" Wood <50% .33 4068 3 4' - 0" 6' - 8" Wood NA NA 5068 2 5' - 0" 6' - 8" Wood NA NA 6068 1 6' - 0" 6' - 8" Wood >50% .33 All Door Sizes Based on Information Provided By Owner Contractor is Responsible For Actual Sizes And Local Code Requirements * On Plan Denotes Tempered Glass Required Locations E On Plans Denotes Egress Locations Windows Make and Mullion Pattern To Be Determined By Owner Contractor is Responible For Actual Sizes and Local Code Requirements REV DATE DESCRIPTION x x x x x x 4200 LB HOLD DOWNS x 1800 Lb Hold Down 3' S Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12" Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6" UP 4'-0" BRACE PANEL ALTERNATE BRACE PANEL HOLDOWN -CAPACITY 1,800 LBS UPLIFT 0' - 6 7 / 8 " 0' - 10 1/2" The plans are the joint property of B'n'R Drafting and the Client. They are not to be reproduced or to be used for any construction except by express written consent by one of the owning parties. B'n'R Drafting assumes no liability beyond the production of these plans. All information contained has been exclusively provided by the client and are accepted as is. Th e s e p l a n s h a v e b e e n p r e p a r e d b y a n A D D A C e r t i f i e d D r a f t e r t o a p p r o v e d dr a f t i n g p r a c t i c e s . A l l i n f o r m a t i o n c o n t a i n e d i n t he s e p l a n s h a v e b e e n pr o v i d e d b y t h e c u s t o m e r a n d h a s b e e n a c c e p t e d a s i s. B ' n ' R D r a f t i n g Se r v i c e s h a s h a d n o i n v o l v e m e n t i n t h e C i v i l , S t r u c tu r a l , M e c h a n i c a l o r El e c t r i c a l E n g i n e e r i n g f o r t h i s p r o j e c t u n l e s s e x p l ic i t l y n o t e d . B ' n ' R D r a f t i n g Se r v i c e s w i l l n o t p e r f o r m a n y s e r v i c e s r e s e r v e d f o r a n A r c h i t e c t o r E n g i n e e r . Al l L i a b i l i t y f o r t h i s p r o j e c t r e m a i n s s o l e l y w i t h th e c o n t r a c t o r , s u b c o n t r a c t o r s an d O w n e r . F i n a l P l a n s a r e a c c e p t e d A S I S . 1993 N. 37th E Idaho Falls, Idaho 83401 208-589-8383 DATE: DRAWN BY: PROJECT: FOR ofB'n'R DraftingServices LLCRRS 8 Sept 2021 2104059 Saul & Cindy DeLaCruz 6 SINGLE FAMILY DWELLING SECTION AND DETAILS 4 - - - - - - - - - - - - - - - 1/8" = 1'-0"1 BRACE WALL PANEL LAYOUT Contractor must specify a vapor retarder on all non-vented "warm-in-winter" side of all framed ceilings, walls, and crawl space floors. Contractor may specify plastic vapor barrier or Vapor Retarder rated Paint. All breaches in the barrier system to be caulked and sealed. VAPOR RETARDING: MINIMUM INSULATION R-VALUE Ceiling R-49 Walls R-21 Floors R-21 Basement R-13 Footing 10"x 20" w/ (3) #4 Cont Foundation Wall - 8" Wall w/ #4 @ 14 o.c. Vert * Shovel Footing - 10"x16" w/ (2) #4 * (2) #4 Horz Within 12" of Top of Wall JOB SPECIFIC INFORMATION DRAWN BY B'N'R DRAFTING SERVICES Interior Walls 2x4 Studs Framed @ 16" O.C. (2) 2x4 Top Plates (1) 2x4 Bottom Plate 1/2" Gypsum Board Both Sides Taped And Prep'd For Interior Finish Floor Joist Blocking Req'd Under Bearing Walls 9' -1" 8" 7/16" Ext. APA Rated Roof Sheathing W/ Clips & Nailing 6" O.C. Edges 10" O.C. Field Architectural Grade, 25 Year Asphalt Shingles (R801-R907) Engineered Trusses Ref Roof Layout Drawings 15# Building Felt Snow/Ice Shield (See Notes) Fascia W/ Style "D" Metal Drip Edge Min R-49 Insulation 5/8" Gypsum Board Taped And Prepared For Interior Finish 2x6 Dbl Top Plate 2x6 Studs @ 16" O.C. R-21 Fiberglass Insulation Poly Vapor Barrier 7/16" Ext APA Rated Wall Sheathing Nailed @ 6" O.C. Edges, And 12" O.C. Field 2x6 Bottom Plate 3/4" T&G APA Rated Sub-Flooring Nailed @ 6" O.C. Edges, 10" O.C. Field R-21 Insulation Floor Joists (As Per Floor Framing Layout) Rim Joist (As Per Floor Framing Layout) 2x Treated Sill Plate W/ Foam Sill Sealer Finish Grade 3/8" Soffit Sheathing W/ 3" Cont. Soffit Venting Add'l 2x4 Support As Req'd 1/2" Gypsum Board Taped And Prepared For Interior Finish 5/8" Gypsum Board Taped And Prepared For Interior Finish Ref To Arch Elev And Cross Section For Fascia Design 9' -0"2x4 Firring W/ Dbl 2x Top Plate And 2x Sill Plate W/ R-13 Batt Insulation and 6-Mil Poly Vapor Barrier 8" Concrete Wall 4" Concrete Slab 1/2" Dia Anchor Bolt W/7" Min Embed. @ 6'-0" O.C. W/ 2"x 2"x 3/16"Thick Plate Washer. Located 12" Max From All Corners Or Splices. Min (2) Anchor Bolts Per Sill Plate. Damp Proofing Compacted Washed Gravel W/ Visqueen Barrier 5/8" Gypsum Board Taped and Prepared For Interior Finish DRAWN BY B'N'R DRAFTING SERVICES Typical Wall Section Standard Hook REV DATE DESCRIPTION 1/4" = 1'-0"2 Section 1 3"x3" x You must follow the 2018 IRC energy code requirements. MAIN FLOOR 1' -2 1/4" DBL TOP PLATE 9' -3 1/4" T.O. CONCRETE 0" BASEMENT FTG -8' -4" 8' - 1 " GARAGE FTG -3' -0" Face Surface -803 sq.ft Rock Area -482 sq.ft = 60% MAIN FLOOR 1' -2 1/4" DBL TOP PLATE 9' -3 1/4" T.O. CONCRETE 0" BASEMENT FTG -8' -4" GARAGE FTG -3' -0" The plans are the joint property of B'n'R Drafting and the Client. They are not to be reproduced or to be used for any construction except by express written consent by one of the owning parties. B'n'R Drafting assumes no liability beyond the production of these plans. All information contained has been exclusively provided by the client and are accepted as is. Th e s e p l a n s h a v e b e e n p r e p a r e d b y a n A D D A C e r t i f i e d D r a f t e r t o a p p r o v e d dr a f t i n g p r a c t i c e s . A l l i n f o r m a t i o n c o n t a i n e d i n t he s e p l a n s h a v e b e e n pr o v i d e d b y t h e c u s t o m e r a n d h a s b e e n a c c e p t e d a s i s. B ' n ' R D r a f t i n g Se r v i c e s h a s h a d n o i n v o l v e m e n t i n t h e C i v i l , S t r u c tu r a l , M e c h a n i c a l o r El e c t r i c a l E n g i n e e r i n g f o r t h i s p r o j e c t u n l e s s e x p l ic i t l y n o t e d . B ' n ' R D r a f t i n g Se r v i c e s w i l l n o t p e r f o r m a n y s e r v i c e s r e s e r v e d f o r a n A r c h i t e c t o r E n g i n e e r . Al l L i a b i l i t y f o r t h i s p r o j e c t r e m a i n s s o l e l y w i t h th e c o n t r a c t o r , s u b c o n t r a c t o r s an d O w n e r . F i n a l P l a n s a r e a c c e p t e d A S I S . 1993 N. 37th E Idaho Falls, Idaho 83401 208-589-8383 DATE: DRAWN BY: PROJECT: FOR ofB'n'R DraftingServices LLCRRS 8 Sept 2021 2104059 Saul & Cindy DeLaCruz 6 SINGLE FAMILY DWELLING ELEVATION 5 - - - - - - - - - - - - - - - 1/4" = 1'-0"1 Front Elevation 1/4" = 1'-0"2 Rear Elevation REV DATE DESCRIPTION Street Number Displayed on House Roof Ventilation as per R806 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. Minimum Frost Depth Ground Surface to Bottom of Footing 36" MAIN FLOOR 1' -2 1/4" DBL TOP PLATE 9' -3 1/4" T.O. CONCRETE 0" BASEMENT FTG -8' -4" GARAGE FTG -3' -0" MAIN FLOOR 1' -2 1/4" DBL TOP PLATE 9' -3 1/4" T.O. CONCRETE 0" BASEMENT FTG -8' -4" GARAGE FTG -3' -0" Ridge Ri d g eValleyHipValley8/12HipHipRi d g eHip8" / 12" 8" / 12" 8" / 12" 6" / 1 2 " 6" / 1 2 " 8" / 12" 8" / 12" 8" / 12" 8' Flat Ceiling To Match House Ceiling To Match House 8' Flat TrayVault 4/ 1 2 4/ 1 2 The plans are the joint property of B'n'R Drafting and the Client. They are not to be reproduced or to be used for any construction except by express written consent by one of the owning parties. B'n'R Drafting assumes no liability beyond the production of these plans. All information contained has been exclusively provided by the client and are accepted as is. Th e s e p l a n s h a v e b e e n p r e p a r e d b y a n A D D A C e r t i f i e d D r a f t e r t o a p p r o v e d dr a f t i n g p r a c t i c e s . A l l i n f o r m a t i o n c o n t a i n e d i n t he s e p l a n s h a v e b e e n pr o v i d e d b y t h e c u s t o m e r a n d h a s b e e n a c c e p t e d a s i s. B ' n ' R D r a f t i n g Se r v i c e s h a s h a d n o i n v o l v e m e n t i n t h e C i v i l , S t r u c tu r a l , M e c h a n i c a l o r El e c t r i c a l E n g i n e e r i n g f o r t h i s p r o j e c t u n l e s s e x p l ic i t l y n o t e d . B ' n ' R D r a f t i n g Se r v i c e s w i l l n o t p e r f o r m a n y s e r v i c e s r e s e r v e d f o r a n A r c h i t e c t o r E n g i n e e r . Al l L i a b i l i t y f o r t h i s p r o j e c t r e m a i n s s o l e l y w i t h th e c o n t r a c t o r , s u b c o n t r a c t o r s an d O w n e r . F i n a l P l a n s a r e a c c e p t e d A S I S . 1993 N. 37th E Idaho Falls, Idaho 83401 208-589-8383 DATE: DRAWN BY: PROJECT: FOR ofB'n'R DraftingServices LLCRRS 8 Sept 2021 2104059 Saul & Cindy DeLaCruz 6 SINGLE FAMILY DWELLING ELEVATION 6 - - - - - - - - - - - - - - - 1/4" = 1'-0"1 Right Elevation 1/4" = 1'-0"2 Left Elevation 1/8" = 1'-0"3 ROOF CONTOUR 1/8" = 1'-0"4 CEILING CONTOUR CRICKETS ARE TO BE FIELD LOCATED AS NEEDED TO INSURE PROPER DRAINAGE, REV DATE DESCRIPTION Roof Ventilation as per R806 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) ~ Oak Hill Circle ~ 60' - 8" Pine Brook Estates Div 2 Block 5 Lot 9 Rexburg, ID ~ O ak Hill W ay ~ P U E Typ 15' - 0" 1 6 ' - 3 " 28' - 6" 7 2 ° 0 5 ' 4 5 " 2 0 5 .2 5 'N E 27° 10' 22" 229.00' S W 5 7° 2 3' 4 5" 1 2 9.8 3' N W R = C H = C B =4 0 . 8 3 ' 2 5 . 0 0 ' 2 ° 3 9 ' 3 3 " R= CH= CB= 36.26' 60.00' 34° 29' 34" 35' - 0" 44' - 9" The plans are the joint property of B'n'R Drafting and the Client. They are not to be reproduced or to be used for any construction except by express written consent by one of the owning parties. B'n'R Drafting assumes no liability beyond the production of these plans. All information contained has been exclusively provided by the client and are accepted as is. Th e s e p l a n s h a v e b e e n p r e p a r e d b y a n A D D A C e r t i f i e d D r a f t e r t o a p p r o v e d dr a f t i n g p r a c t i c e s . A l l i n f o r m a t i o n c o n t a i n e d i n t he s e p l a n s h a v e b e e n pr o v i d e d b y t h e c u s t o m e r a n d h a s b e e n a c c e p t e d a s i s. B ' n ' R D r a f t i n g Se r v i c e s h a s h a d n o i n v o l v e m e n t i n t h e C i v i l , S t r u c tu r a l , M e c h a n i c a l o r El e c t r i c a l E n g i n e e r i n g f o r t h i s p r o j e c t u n l e s s e x p l ic i t l y n o t e d . B ' n ' R D r a f t i n g Se r v i c e s w i l l n o t p e r f o r m a n y s e r v i c e s r e s e r v e d f o r a n A r c h i t e c t o r E n g i n e e r . Al l L i a b i l i t y f o r t h i s p r o j e c t r e m a i n s s o l e l y w i t h th e c o n t r a c t o r , s u b c o n t r a c t o r s an d O w n e r . F i n a l P l a n s a r e a c c e p t e d A S I S . 1823 N. 3750 E Idaho Falls, Idaho 83401 208-589-8383 DATE: DRAWN BY: PROJECT: FOR RE V D A T E D E S C R I P T I O NB'n'R DraftingServicesRRS 02/17/06 2104059 Saul & Cindy DeLaCruz Rexburg, Idaho SINGLE FAMILY DWELLING SITE PLAN C1 1" = 10'-0"1 Site This Site plan is based on a legal description provided by others, this site plan is provided by a drafting service. No survey work has been done nor is implied. For Actual boundary lines and corners, a licensed surveyor should be consulted. B'n'R Drafting Services assumes no liability for the accuracy of these documents. Need to draw in sidewalks and ADA Ramp for corner