Loading...
HomeMy WebLinkAboutREDLINED PLANS - 23-00463 - Bodifi - RemodelAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Don Allen Don.Allen@rexburg.org 208-372-2174 Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : Bodifi - Remodel Address : 730 W 7th S Application Type : Document Filename : si 23-013 - Bodify - Rexburg - A1.2 - Const. Plan - Permit Set.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A1.2 Free Text Cody Jones : Building Open 1 Standard roll in type shower minimum dimensions are 60"x30". A1.2 Free Text Cody Jones : Building Open 1 Shower ADA requirements to be in compliance with ICC A117.1. A1.2 Free Text Cody Jones : Building Open 1 Glass to be tempered A1.2 Free Text Cody Jones : Building Open 1 Will plumbing fixtures (shower) count remain the same? A1.2 Free Text Cody Jones : Building Open 1 Plumbing fixture count to comply with occupant load and Idaho plumbing code. A1.2 Free Text Alex Owens : Electrical Open 1 No electrical plans provided. Please provide electrical plans for review. All electrical work to comply with 2017 NEC. # 23-00463 Commercial - Remodel Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 07.25.2023 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) studio THESE DRAWINGS, INCLUDING THE INFORMATION THEREIN, REMAIN THE PROPERTY OF studio i, LLC. THEY ARE PROVIDED SOLEY FOR THE PURPOSE OF CONSTRUCTING THE PROJECT DESCrIBED IN THIS SET OF DoCUMENTS AND SHALL NOT BE MODIFIED, REPRODUCED 0R USED FOR ANY OTHER PURPOSE, project or location WITHOUT THE WRITTEN APPROVAL OF studio i, LLC. SHEET TITLE: SHEET #: PERMIT REVIEW SET RDD RDD CONST. PLAN BODIFi - REXBURG REMODEL 7.18.23 SI 23-013 A1.2 ISSUE DATE: si PROJ. #: DRAWN BY: CHECKED BY: OWNER: REVISIONS: PROJECT NAME: LOCATION: CONSULTANTS: si 23-013 - Bodify - Rexburg.plnFILE NAME: 730 W 7TH S REXBURG, IDAHO 83440 Brian Ball inspiring spacesinspiring spacesinspiring spacesinspiring spaces thoughtful placesthoughtful placesthoughtful placesthoughtful places 3745 w 14000 n3745 w 14000 n3745 w 14000 n3745 w 14000 n feltfeltfeltfelt, id 834, id 834, id 834, id 83424242424 phone: 208.339.5375phone: 208.339.5375phone: 208.339.5375phone: 208.339.5375 website: www.studioi.orgwebsite: www.studioi.orgwebsite: www.studioi.orgwebsite: www.studioi.org architecture architecture architecture architecture + construction construction construction construction keynotes Demo 1. remove exist. wall to extent shown - PATCH AND REPAIR TO MATCH ADJACENT SURFACES 2. REMOVE EXIST. RECEPTION DESK 3. REMOVE EXIST. DOOR AND FRAME - SALVAGE FOR REINSTALLATION construction WIS NEW WALK IN SHOWER ENCLOSURE AS SELECTED BY OWNER SI NEW ADA SHOWER INSERT AS SELECTED BY OWNER IW1 2X4 STUDS W/ 5/8" GYP. BD. EA. SIDE (OR 3 5/8" METAL STUDS) IW2 2X4 STUDS W/ TILE EA. SIDE (OR 3 5/8" METAL STUDS) DC DISPLAY CASE AS SELECTED BY OWNER GP GLASS PARTITION AS SELECTED BY OWNER PS STEEL PARTITION SUPPORT/COLUMN RD NEW RECEPTION DESK - FINAL DESIGN BY OWNER ID INTERIOR DOOR - MATCH EXIST. oWNER OPTION TO RESUSE EXIST. DOORS d1 6'-8" 3'-0" d1 6'-8" 3'-0" d1 6'-8" 3'-0" d1 6'-8" 3'-0" d1 6'-8" 3'-0" D-24 6' - 8 " 3' - 0 " 7'-0" 7'-0" 7'-0" 7'-1 1/2" 7'-0" 1'-5" 5'-1" fv 7'-9 1/2" 35'-1 1/2"1'-5" 3 1 / 2 " 1 3 ' - 0 " F V 3 1 / 2 " 8 ' - 8 " 3 1 / 2 " 8 ' - 6 " 3 1 / 2 " 8 ' - 5 1 / 4 " 5 1 / 2 " 9' - 2 1 / 2 " 3 1 / 2 " 4'-9" 4'-9" 4'-9" 4'-9" 4'-9" 4'-2" 4' - 9 " 4 ' - 9 " 3 ' - 0 " 7'-10" 3'-2" 3' - 2 " 3'-2" 3' - 2 " 4' - 8 " f v 4' - 8 " f v 4' - 8 " f v 4' - 8 " f v 3'-0" 7' - 0 " 1 9 ' - 0 " 22'-0" R 16'-0" IW1 RD si wis wis si wis wis GP PS DC DC DC DC DC IW1 GP PS IW1 IW1 IW1 IW1 IW1 IW1 IW1 IW1 IW1 GP GP RD IW2 IW2 typ. typ. typ. typ. EXIST. WORKOUT AREA KIDS WORLD EXPANSION CONSUL. OFF OFF OFF CONSUL. RECPT Open area SCALE: 3/16" = 1'-0" 2 FIRST FLOOR CONST. PLAN 0 4' 8' 12' Glass to be tempered P lu mbin g fix tu re c ou n t to c omply w ith oc c u pan t load an d Idah o plu mbin g c ode. S tan dard roll in ty pe sh ow er min imu m dimen sion s are 6 0 "x 3 0 ". S h ow er A D A req u iremen ts to be in c omplian c e w ith IC C A 1 1 7 .1 . N o elec tric al plan s prov ided. P lease prov ide elec tric al plan s for rev iew . A ll elec tric al w ork to c omply w ith 2 0 1 7 N E C . W ill plu mbin g fix tu res (sh ow er) c ou n t remain th e same?