Loading...
HomeMy WebLinkAboutDRAWINGS WITH CORRECTIONS - 23-00173 - Beehive Federal Credit UnionN NORTH ARROW ROOM . ROOM NAME ROOM NAME TAG ROOM NUMBER . . SECTION NUMBER BUILDING SECTION TAG PAGE NUMBER SYMBOLS LEGEND BREAK LINE SCALE: . ?" = 1'-0" DETAIL . DETAIL NUMBER DETAIL TITLE TAG PAGE NUMBER SCALE: . ?" = 1'-0" ELEVATION . INT. ELEV. TITLE TAG SCALE: ?" = 1'-0" TITLEMAIN TITLE TAG SCALE: . ?" = 1'-0" SECTION . DETAIL NUMBER PAGE NUMBER DETAIL NUMBER SECTION TITLE TAG PAGE NUMBER FINISHED FLOOR ELEV. 100'-0"ELEVATION TAG 1 REVISION TAG WALL TYPE TAG D-DOOR TYPE TAG W-WINDOW TYPE TAG ?KEYNOTE TAG R-ROOF TYPE TAG ROOM FINISHES TAG SCALE: . ?" = 1'-0" ELEVATION . EXT. ELEV. TITLE TAG DETAIL NUMBER PAGE NUMBER A101 1 DETAIL NUMBER DETAIL TAG PAGE NUMBER N E F S WB N1 E1 S1 W1 B1 F1 ADDITIONAL FINISH NOTES PLAN SOUTH WALL FINISH BASE FINISH PLAN WEST WALL FINISH PLAN NORTH WALL FINISH FLOOR FINISH ADDITIONAL FINISH NOTES PLAN EAST WALL FINISH 300 STOREFRONT TYPE TAG 9.6A-1 WALL'S FIRE RATING - HR UNIQUE WALL TYPE CONFIGURATION STRUCTURAL MATERIAL TYPE - CSI DIVISIONS STRUCTURAL MATERIAL WIDTH VICINITY MAP: REXBURG, IDAHO PROJECT LOCATION HWY 20 HWY 33 2N D E A S T MOODY ROAD DESIGN TEAM OWNER ARCHITECT CIVIL ENGINEERS LANDSCAPE ARCHITECT STRUCTURAL ENGINEERS MECHANICAL ENGINEERS ELECTRICAL ENGINEERS BEEHIVE FEDERAL CREDIT UNION CRAIG GUMMOW - CEO 1087 ERIKSON DRIVE REXBURG, IDAHO 83440 PHONE: (208) 656-1000 NBW ARCHITECTS P.A. 990 JOHN ADAMS PARKWAY IDAHO FALLS, IDAHO 83401 PHONE: (208) 522-8779 FAX: (208) 522-8785 CONNECT ENGINEERING 2295 N YELLOWSTONE HWY, STE #6 IDAHO FALLS, IDAHO 83401 PHONE: (208) 881-0081 BRECKON LAND DESIGN 6661 N. GLENWOOD ST GARDEN CITY, IDAHO 83714 PHONE: (208) 376-5153 FROST STRUCTURAL ENGINEERING 1020 E. LINCOLN RD. IDAHO FALLS, IDAHO 83401 PHONE: (208) 227-8404 ENGINEERED SYSTEMS ASSOCIATES 1355 EAST CENTER ST. POCATELLO, IDAHO 83201 PHONE: (208) 233-0501 FAX: (208) 233-0529 PAYNE ENGINEERING, INC. 1823 EAST CENTER ST. POCATELLO, IDAHO 83201 PHONE: (208) 232-4439 FAX: (208) 232-1435 ABBREVIATIONS # - NUMBER OR POUND & - AND A.F.F. - ABOVE FINISH FLOOR AL - ALUMINUM ALUM. - ALUMINUM B.O. - BOTTOM OF CMU - CONCRETE MASONRY UNIT CONC. - CONCRETE CONT. - CONTINUOUS DEMO. - DEMOLITION OR DEMOLISH DIA. - DIAMETER DN - DOWN EA. - EACH EIFS - EXTERIOR INSULATION & FINISHING SYSTEM ELEC. - ELECTRICAL ELEV. - ELEVATION EQ. - EQUAL EQUIP. - EQUIPMENT EXT. - EXTERIOR F.F. - FINISH FLOOR FRP - FIBERGLASS REINFORCED PLASTIC GA. - GAUGE GYP. - GYPSUM H.M. - HOLLOW METAL HR - HOUR HVAC - HEATING, VENTILATING, & AIR CONDITION I.D. - INSIDE DIAMETER I.M.P. - INSULATED METAL PANEL INSUL. - INSULATION INT. - INTERIOR MAX. - MAXIMUM MECH. - MECHANICAL MFR - MANUFACTURER MIN. - MINIMUM N.I.C. - NOT IN CONTRACT NO. - NUMBER O.C. - ON CENTER O.D. - OUTSIDE DIAMETER PLY - PLYWOOD PLUM. - PLUMBING PVC - POLYVINYL CHLORIDE RCP - REFLECTED CEILING PLAN REQ'D - REQUIRED SIM. - SIMILAR SPM - SINGLE PLY MEMBRANE STOR. - STORAGE STRUCT. - STRUCTURAL T.O. - TOP OF TYP. - TYPICAL U.N.O. - UNLESS NOTED OTHERWISE W/ - WITH W.C. - WATER CLOSET WD - WOOD I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 9 : 1 5 : 3 4 A M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t G1.0 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . GE N E R A L I N F O R M A T I O N APRIL 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 NEW BUILDING FOR: BEEHIVE FCU - NORTH REXBURG CORNER OF 2ND EAST AND MOODY RD. REXBURG, IDAHO 83440 CJR GLN DRAWING INDEX GENERAL G1.0 GENERAL INFORMATION G1.1 CODE ANALYSIS G1.2 ANSI STANDARDS CIVIL C1.00 COVER C2.00 NOTES C3.00 REFERENCE SHEET C4.00 EXISTING CONDITIONS C5.00 GENERAL LAYOUT C6.00 UTILITY LAYOUT C7.00 GRADING C8.00 DETAILS C9.00 DETAILS 2 C10.0 STORMTECH DETAILS C11.0 EROSION CONTROL LANDSCAPE L1.1 LANDSCAPE PLAN L1.5 LANDSCAPE DETAILS L2.1 IRRIGATION PLAN L2.5 IRRIGATION DETAILS L2.6 IRRIGATION DETAILS SITE DESIGN SP1.1 SITE PLAN - HORIZONTAL CONTROL SP2.1 SITE DETAILS SP2.2 SITE DETAILS SP2.3 SITE DETAILS ARCHITECTURAL A1.0 WALL AND ROOF TYPES A1.1 DIMENSION PLAN A1.2 ANNOTATION PLAN A1.3 REFLECTED CEILING PLAN A1.4 SIGNAGE, FLOOR FINISHED, AND DETAILS A1.5 OWNER FURNISHED PLAN A2.1 BUILDING ELEVATIONS A3.1 BUILDING SECTIONS A3.2 BUILDING SECTIONS A3.3 3D SECTIONS A4.1 WALL SECTION A4.2 WALL SECTIONS A4.3 WALL SECTIONS A4.4 ENLARGED SECTIONS AND ELEVATION A5.1 ENLARGED PLANS AND ELEVATIONS A5.2 ENLARGED PLANS, ELEVATIONS, AND SECTIONS A5.3 CASEWORK DETAILS A5.4 FLOOR PLAN DETAILS A6.1 DOOR SCHEDULE & ELEVATIONS A6.2 DOOR AND WINDOW DETAILS A7.1 ROOF PLAN A7.2 ROOF DETAILS PROJECT PERSPECTIVE DRAWING INDEX STRUCTURAL S1.0 GENERAL STRUCTURAL NOTES S1.1 SPECIAL INSPECTIONS S1.2 TYPICAL DETAILS S1.3 TYPICAL DETAILS S2.0 FOUNDATION PLAN S2.1 LOWER ROOF FRAMING PLAN S2.2 UPPER ROOF FRAMING PLAN S3.0 FOUNDATION DETAILS S3.1 FOUNDATION DETAILS S4.0 ROOF FRAMING DETAILS S4.1 ROOF FRAMING DETAILS S4.2 ROOF FRAMING DETAILS S4.3 ROOF FRAMING DETAILS MECHANICAL M1.0 MECHANICAL FOUNDATION PLAN M1.1 MECHANICAL FLOOR PLAN M2.1 MECHANICAL DETAILS M3.1 EQUIPMENT SCHEDULE AND DETAILS PLUMBING P1.0 PLUMBING FOUNDATION PLAN P1.1 PIPING FLOOR PLAN P2.1 PLUMBING DETAILS AND DIAGRAMS ELECTRICAL E0.0 ELECTRICAL SYMBOLS AND DETAILS E0.1 ELECTRICAL SITE PLAN E1.0 LIGHTING PLAN E2.0 POWER/DATA PLAN E3.0 POWER RISER AND SCHEDULE E3.1 ELECTRICAL SCHEDULES AND DETAILS CODE ANALYSIS RELEVANT CODES: BUILDING/STRUCTURAL: 2018 IBC ELECTRICAL: 2017 NEC PLUMBING:2017 IPC MECHANICAL:2018 IMC FIRE:2018 IFC ENERGY:2018 IECC BUILDING OCCUPANCY: B -BUSINESS RISK CATEGORY (1604.5) RISK CATEGORY II CONSTRUCTION TYPE: TYPE V-B, NON-PROTECTED NON FIRE SPRINKLED. CONSEALED SPACES TO HAVE FIRE BLOCKING AND DRAFT STOPPING INSTALLED AS PER SECTION 718. VENTILATION TO PROVIDE AND COMPLY WITH SECTION 1203. ALLOWABLE HEIGHT AND AREA: ALLOWED STORIES -2 AREA -9,000 SQFT HEIGHT -40' ACTUAL STORIES -1 AREA -2,676 SQFT HEIGHT -21'-6" AREA BY OCCUPANCY GROUP: MAIN LEVEL B 2,676 SQFT TOTAL 2,676 SQFT FIRE RESISTANCE HOUR-RATING FOR BUILDING ELEMENTS (TABLE 601): TYPE V-B, ALL ELEMENTS -0-HR OCCUPANT EGRESS WIDTH: EGRESS WIDTH 29 X 0.2 = 5.8" REQ'D OR 36" MIN. -108" PROVIDED (1005.3.2) TRAVEL DISTANCE 200' MAXIMUM -72' ACTUAL COMMON PATH OL ≤30, NS = 100FT MAX. // ACTUAL = 37'-0" // NOTE: 2ND EXIT IS NOT REQ'D, BUT IS PROVIDED DEAD END CORRIDOR NOT APPLICABLE ADA TELLER SERVICE COUNTER:ADA MEMBERS TO RECEIVE BANKING SERVICES IN ADJACENT OFFICES WHERE DESKS MEET HEIGHT REQUIREMENT. BUILDING INFORMATION: HEIGHT OF BUILDING: 21'-6" NUMBER OF STORIES: 1 WATER CLOSET COUNT:(TOILET ROOMS TO UNISEX) OCC.LOAD CODE REQ'D PROVIDED B-MALE 14 1/25 (1st 50)1 1 B-FEMALE 15 1/25 1 1 LAVATORY COUNT: OCC.LOAD CODE REQ'D PROVIDED B-MALE 14 1/40 (1st 80)1 1 B-FEMALE 15 1/40 (1st 80)1 1 DRINKING FOUNTAIN COUNT: OCC.LOAD CODE REQ'D PROVIDED B 29 1/100 1 1 DRINKING FOUNTAIN TO BE ADA ACCESSIBLE WITH SECONDARY WATER BOTTLE FILL STATION. SERVICE SINK COUNT: OCC.LOAD CODE REQ'D PROVIDED B NA NA 1 1 ZONING REQUIREMENTS: LAND USE: CBC REQUIRED PARKING STALLS = 3 PARKING STALL PER 1000 SQ. FT. (2,676 / 1000) = 2.67 * 3 = 9 STALLS // ACTUAL PROVIDED = 25 STALLS REQUIRED ADA STALLS: 1 -25 = 1// ACTUAL PROVIDED = 1 ADA STALL (VAN ACCESSIBLE) 1B MANAGER 103 1B OFFICE 1 104 2B DRIVE-THRU 106 9A BREAK 107 1B TOILET 118 1B TOILET 117 1S I.T. 116 1S MECH. 111 1S JAN./STOR. 112 1B OFFICE 2 113 1B OFFICE 3 115 1B HALLWAY 108 7B MAIN LOBBY 102 17 12 1B VESTIBULE 101 OCCUPANCY LOAD PLAN KEY ACCESSORY 300 GROSS S BUSINESS 150 GROSS B ASSEMBLY 15 NET A A ROOM NAME ROOM # 30 FACTOR GROSS/ OCCUPANCY LOAD TYPE (SF) NET SYM. TOTAL EGRESS LOAD = 29 OCCUPANT LOAD (AREA / LOAD FACTOR) OCCUPANT LOAD TYPE SYMBOL 10 OCCUPANT LOAD SERVED BY EXIT I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 2 0 / 2 0 2 3 7 : 0 8 : 1 3 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h R e x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e hi v e F C U N o r t h R e x b u r g v _ 2 3 . r v t G1.1 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . CO D E A N A L Y S I S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE:3/16" = 1'-0" G1.1 1 CODE ANALYSIS 1 City Plan Review 4/21/23 1 1 1 38 " 52 " M A X . 44 " M A X . 44 " M A X . 38 " M A X . 18 " - 4 8 " SEE "DISPENSER AREAS" ON TOILET GRAB BAR DIMENSIONS 39 " - 4 1 " 1 8 " M I N . 33 " - 3 6 " 42" MIN. 12" MAX. 39" - 41" WALLDISPENSER AREAS 24" MIN. 12" MIN. 33 " - 3 6 " WALL 32 " M A X . 48 " M I N . 9" M I N . 60 " 1 1 " TOE SPACE 6" MIN. MI N . 15 " AD A U N I T S 48 " M A X . LA T C H 48 " M A X . 48 " MIRROR DISPENSERS PAPER TOWEL DISPENSER SOAP DISPENSER ELECTRIC HAND DRYER TOILET SEAT COVER TOILET PAPER DISPENSER TOILET GRAB BARS BABY CHANGING TABLE SIGNAGE TOILET PARTITIONS SINGLE TIER LOCKER FIRE EXTINGUISHER CABINETTOILET GRAB BARS ACCESSORIES MOUNTING HEIGHTS SCALE: 3/8" = 1'-0" MI N . 9" 27 " M I N . 29 " 34 " M A X . 16"-18" 17 " - 1 9 " 17" 17 " M A X . 36 " M A X . 27 " M I N . 38 " - 4 3 " 5" MAX.15" MIN. 8" MIN. 11" MIN. MIN. 30" CLEAR LAVATORY WATER CLOSET URINAL AND SCREENS DRINKING FOUNTAIN 12 " 60 " 44 " M A X " 18 " M I N . MI N . 1 1 / 2 " 48 " M A X . 42" MAX. 24" MIN. 36" MIN. 18" MIN. 60 " M I N . FRONT APPROACH, PULL SIDE 12" MIN.*48 " M I N . FRONT APPROACH, PUSH SIDE *IF BOTH CLOSER AND LATCH ARE PROVIDED 36" MIN. 60 " M I N . HINGE APPROACH, PULL SIDE 42" MIN. 54 " M I N . HINGE APPROACH, PULL SIDE 22" MIN.42 " M I N . * * HINGE APPROACH, PUSH SIDE 12" MIN.* *IF BOTH CLOSER AND LATCH ARE PROVIDED ** 48" MIN. IF BOTH CLOSER AND LATCH ARE PROVIDED 24" MIN.48 " M I N . * LATCH APPROACH, PULL SIDE *54" MIN. IF CLOSER IS PROVIDED 42 " M I N . * LATCH APPROACH, PUSH SIDE 24" MIN. * 48" MIN. IF CLOSER IS PROVIDED 48 " M I N . FRONT APPROACH - SLIDING, FOLDING, OR NO DOOR 42 " M I N . SIDE APPROACH, NO DOOR CLEARANCE WIDTH FOR SLIDING, FOLDING, OR HINGED DOORS 32" MIN. X > 2 4 " 36" MIN. CLEARANCE WIDTH FOR DOORWAYS WITHOUT DOORS 60 " M I N . 60" MIN. 60 " M I N . DOOR WIDTH 48" MIN. DOOR WIDTH 60 " M I N . 48" MIN. DOOR WIDTH DOORS IN A SERIES DOORS SWING OUT DOORS IN A SERIES DOORS SWING IN DOORS IN A SERIES DOORS SWING SAME DIRECTION 90. 00° 48 " M A X 34 " M I N . DOOR HARDWARE MOUNTING HEIGHT LATCH, LOCK, PULL, OR EXIT DEVICE 60" MIN. 56 " M I N . *OTHER FIXTURES NOT ALLOWED WITHIN THIS AREA 59 " F O R F L O O R M O U N T W . C . 56 " F O R W A L L H U N G W . C . 60" MIN. 59" FOR FLOOR MOUNT W.C. 56" FOR WALL HUNG W.C. 60 " M I N . 42" MIN. 4" M A X . 55 " M I N . 52 " M I N . O R 36" MIN. 60 " 42 " M I N . CL E A R 17" - 19" 48" MIN. 30 " M I N . CLEAR FLOOR SPACE 60" MIN. TURNING CIRCLE 60 " 60" 12" 36" 12" 36 " 2 4 " T-SHAPED TURNING AREA 48" MIN. 30 " M I N . PARALLEL CLEAR FLOOR SPACE 48 " M I N . 30" MIN. FORWARD CLEAR FLOOR SPACE PARALLEL APPROACH IN ALCOVE 60" MIN. X > 1 5 " FORWARD APPROACH IN ALCOVE 36" MIN. X > 2 4 " 42" MIN. X 42" MIN. 48 " M I N . 36" MIN. X 36" MIN. 60 " M I N . 180° TURN 180° TURN (EXCEPTION) 24" MAX. 48" MIN. 24" MAX. 32 " M I N . 36 " M I N . CLEAR WIDTH FOR ACCESSIBLE ROUTE I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 3 : 4 6 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t G1.2 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . AN S I S T A N D A R D S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE:3/8" = 1'-0" FIXTURE MOUNTING HEIGHTS SCALE: 3/8" = 1'-0" DOOR CLEARANCES SCALE: 3/8" = 1'-0" W.C. CLEARANCES SCALE: 3/8" = 1'-0" FLOOR CLEARANCES STATE MAP SITE MAP VICINITY MAP REXBURG, ID DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : SLH 2022-006 PDH BE E H I V E F C U - N O R T H R E X B U R G 4/26/23 CO V E R C1.00 SITE LOCATION SURVEY NOTE: This site plan conforms to an actual survey that was performed on the ground by a licensed land surveyor in and for the State of Idaho. It is the owner’s responsibility to construct all structures shown on this site plan in accordance with said survey. APPROVED BY ________________________DATE:____________ City of REXBURG Sheet List Table Sheet Number Sheet Title C1.00 COVER C2.00 NOTES C3.00 REFERENCE SHEET C4.00 EXISTING CONDITIONS C5.00 GENERAL LAYOUT C6.00 UTILITY LAYOUT C7.00 GRADING C8.00 DETAILS C9.00 DETAILS 2 C10.0 STORMTECH DETAILS C11.0 EROSION CONTROL 4/26/2023 Minor Grading Revisions Made From 1st City Review Set See Grading Sheet City Review Set#2 CONTACTS DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : SLH 2022-006 PDH BE E H I V E F C U - N O R T H R E X B U R G 4/26/23 NO T E S C2.00 DEPARTMENT OF ENVIRONMENTAL QUALITY 900 N SKYLINE, SUITE B IDAHO FALLS, IDAHO 83402 (208) 528-2650 INTERMOUNTIAN GAS COMPANY 1527 HOLLIPARK DR IDAHO FALLS IDAHO, IDAHO 83401 (208) 542-6632 ROCKY MOUNTAIN POWER 170 W 2ND N REXBURG, ID 83440 (888) 221-7070 CITY OF REXBURG 35 N 1ST E, REXBURG, ID 83440 (208) 359-3020 APPROVED BY ________________________DATE:____________ City of REXBURG SPARKLIGHT 1525 SHERRY DR. IDAHO FALLS, ID 83403 (208) 523-4567 GENERAL NOTES 1.All materials, workmanship, and construction of site improvements shall meet or exceed the work standards and specifications set forth by the CITY OF REXBURG standard specifications and drawings, and requirements of the Idaho Standards for Public Works Construction, (ISPWC) current edition. 2.All material furnished on or for the project must meet the minimum requirements of the approving agencies or as set forth herein, whichever is more restrictive. 3.The Contractor is cautioned that the location and/or elevation of existing utilities, as shown on these plans, is based on records of the various utility companies and where possible, measurements taken in the field. The Contractor must call the local utility location center at least 48 hours before any excavation to request exact field locations of the utilities. 4.A Pre-Construction Conference shall be held a minimum of three (3) working days prior to start of work. All Contractors, Subcontractors and/or Utility Contractors shall be present. 5.All lot dimensions and easements are to be taken from the Final Plat of the recorded subdivision plat. 6.The Contractor shall maintain all existing drainage and sanitary sewer facilities within the construction area until the drainage improvements are in place and functioning. 7.All Contractors working within the project boundaries are responsible for compliance with all applicable safety laws of any jurisdictional body including but not limited to, barricades, safety devices, control of traffic, excavation, trenching, shoring, and security within and around the construction area. 8.Contractors must furnish proof that all materials installed on this project meet the requirements of Note # 2 above at the request of the agency and/or Engineer. 9.CONNECT ENGINEERING must give approval prior to (a) backfilling trenches for pipe; (b) placing of aggregate base; (c) placing of concrete; (d) placing of asphalt pavement. Work done without such approval shall not relieve the Contractor from the responsibility of performing the work in an acceptable manner. Contract work will not be accepted by the CITY OF REXBURG without the approval of the Project Engineer. 10.Developmental drawings must be submitted to the CITY OF REXBURG Public Works Dept. prior to final approval. 11.Only plan sets marked "Approved for Construction" shall be used by the project contractor(s). Use of any plans on the job without the "Approved of Construction" stamp shall be grounds for the issuance of a stop work order. Contractor must also maintain a set of plans stamped with approval by the Department of Environmental Quality on site. 12.Contractor is responsible for property corner protection. The cost of $30 per corner will be held as retainage until all interior corners are verified to be in place. 13.Each Contractor shall be responsible for acquiring any necessary NPDES permits, filing any NOI's or NOT's, and preparing a Storm Water Pollution Prevention Plan (SWPPP) in accordance with the Environmental Protection Agency. Contact the EPA at 208.378.5776 for the required information. Said permit shall be presented to the Engineer at least forty-eight (48) hours prior to the beginning of construction. 14.The Contractor shall be responsible for keeping roadways free and clear of all construction debris and dirt tracked in from the site. 15.All measures possible shall be taken to ensure erosion control with Best Management Practices. 16.Quantities shown are estimates by the Engineer. The Contractor must verify all quantities. If there is a large discrepancy contact the Engineer. 17.All work must meet standards set forth by the American Disabilities Act (ADA) inside public rights of way. 18.Trench backfill Type 2A compaction "Water Settling" will not be an acceptable method of trench backfill compaction. 19.All water valves, blow-offs and manholes will be placed so as not to conflict with any concrete curb, gutter, valley gutter, and sidewalk improvements. 20.CONNECT ENGINEERING and/or Inspector shall make periodic visits to the project location to ensure that the site improvements meet or exceed standards and design as per the approved construction drawings. 21.To receive final acceptance, Contractor must submit copy of field plans complete with construction notes and As-Built information, corrections, changes, etc. 22.Contractor must have ISPWC manual (current edition) on-site during all phases of construction. Failure to do so may result in non-acceptance of the site by DEQ, Engineer, City etc. 23.A copy of the Quality Control Signature sheet (with all applicable signatures) shall be delivered to CONNECT ENGINEERING prior to the walk-thru. 24.A Right-of-Way Construction Permit from the CITY OF REXBURG Public Works is required for any construction in the road right-of-way not shown on these improvement drawings. 25.Contractors shall provide a one (1) year warranty on all roads from the date of formal acceptance by the CITY OF REXBURG. 26.Lot corners and centerline intersection monuments have been staked as shown on the recorded plat of this subdivision. Should any of these monuments be lost or disturbed during construction Idaho Code 55-1613 requires said monuments will be reestablished by a professional land surveyor at the expense of the agency or person causing the loss or disturbance. 27.All Construction Staking shall be provided by the general contractor. If restaking is required this shall be provided at the Contractors expense. 28.It is the contractors reasonability to know which permits are needed and obtain all construction permits including ROW for bore. 29.Plans are intended to be printed in color for added clarity of design. STREET CONSTRUCTION 1.All construction within public right-of-way shall conform to the current edition of the ISPWC and the CITY OF REXBURG standards. No exceptions to Policy Standards and the ISPWC will be allowed unless specifically and previously approved in writing by the CITY OF REXBURG. 2.No construction shall begin before the Pre-Construction meeting, which the Contractor is required to attend. 3.Sanitary sewer and storm drain manholes, cones and structures shall be set to specified elevation by their respective contractors. All remaining manhole materials, except concrete collars, necessary to construct manhole to finished grade in pavement areas shall be furnished by the Contractor for placement at finished grade. For manholes not within pavement areas, the manhole rings shall be set to finished grade by their respective contractor. Contractor shall contact the CITY OF REXBURG twenty-four (24) hours prior to pouring concrete collars. 4.Contractor shall construct four inches (4") of asphalt pavement thickness at joint locations for all pavement matches. 5.All reinforced concrete pipe shall conform to ASTM C-76 Specifications for the class of pipe indicated, and shall be installed watertight. 6.All work will be inspected by CONNECT ENGINEERING and monitored by the CITY OF REXBURG in accordance with the latest edition of the "REXBURG STANDARD DRAWINGS AND SPECIFICATIONS". 7.Borrow shall be obtained from sources designated or approved in writing by the Engineer. 8.Clearing and grubbing shall consist of removing all natural and artificial objectionable materials. Under no circumstances shall roadways be placed on frozen or objectionable material. 9.The subgrade shall be excavated and bladed to remove all uneven areas and to secure a uniform surface true to grade and line. The subgrade material shall then be scarified to a depth of eight inches (8"), adjusted to within approximately 2% of optimum moisture content and compacted to the minimum density required as stated in ISPWC. 10.All concrete used shall be Class 4 and have a strength of four thousand (4000) PSI in twenty-eight (28) days. The concrete mix shall include Fly Ash for ASR mitigation. The mix design shall be approved by the engineer. All concrete shall be cured by a liquid membrane-forming curing compound method, unless otherwise specified in writing by the Engineer. 11.The plant mix should be a 12-inch SP3 PG 58-28, 1 to 10 million design ESALs superpave hot mix asphalt design. 12.All road stripping and excess topsoil shall be stockpiled out of the right-of-way and stored at Contractor's expense. 13.A traffic control plan based on the latest edition of the Manual on Uniform Traffic Control Devices (MUTCD) shall be approved by the CITY OF REXBURG Public Works Department prior to construction. 14.Parked equipment and stored materials shall be kept as far away from the travelway as feasible. Items left overnight within 30 feet of the travel way shall be marked and/or protected. WATER NOTES 1.The water system shall be constructed to conform with the standards set forth in the "Idaho Regulations for Public Drinking Water Systems" and the current CITY OF REXBURG standard drawings and specifications. 2.The pipe shall be installed in a workmanlike manner by persons properly qualified to perform said work and shall be in conformance with the manufacturer's recommendations as approved by the City Engineer. All work and materials must conform to current requirements of the CITY OF REXBURG. Water distribution mains shall be constructed with clas 50 DI pipe, AWWA C-900, DR 18 PVC or Pressure Class 250 DIP. 3.All water services shall be 1" DR7 (200 psi) PE IPS pipe and have a minimum cover of 5 feet per City of REXBURG Std. Dwgs #600-1 and / or 600-3. Cap lines 15' inside property lines after installation of the water mains. The trenches shall be compacted to 95% of maximum density to prevent further settlement. All mains shall be leak-tested, disinfected, flushed and bacteria tested before connecting to the municipal system. Mueller thermal coil meter pit, or equivalent, required for all water services. 4.Where it is necessary for sewer and water to cross each other and the sewer line is above or less than 18 inches below the water main, the sewer line crossing shall be either: a. Non-Potable pipeline construction with potable water class pie for a minimum of ten (10) feet either side of potable pipeline with a single twenty (20) feet section of potable water class pipe centered on the crossing; or b. Sleeve non-potable or potable pipeline with potable water class pipe ten (10) feet either side of crossing. Use of hydraulic cementitous materials such as concrete, controlled density fill, and concrete slurry encasement is not allowed as a substitute for sleeving. If potable pipeline is below non-potable pipeline, the non-potable pipeline must also be supported through the crossing to prevent settling. 5.All tees, plugs, caps and bends, and at other locations where unbalanced forces exist, shall be secured and anchored by concrete thrust blocks as shown IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION. 6.CONNECT ENGINEERING will provide one (1) set of construction stakes for each of the following items: water main lines, fire hydrants, and service connections. 7.Contractor to field verify all valve box lid elevations to assure that said lid elevations match final street grade. 8.The paving contractor shall be responsible for constructing concrete collars and final adjustments of water valves to grade. 9.Pipes laid on a curve: the maximum joint deflection shall be 5 percent or the manufacturer's recommendation, whichever is less. 10.The developer will test the compaction of the water pipeline bedding in accordance with the ISPWC specifications construction inspection policy. Testing will be done by an outside testing laboratory. The cost of this service shall be paid by the developer. However, if the test fails, the cost of the test and any retesting shall be paid by the water contractor. The contractor shall coordinate with the developer's engineer and testing laboratory to schedule the tests, his backfilling, and pipe laying operation. 11.The developer's engineer shall be present during all testing of the water line. 12.The horizontal separation of the water and sanitary sewer, or storm drain shall be a minimum of ten (10) feet. 13.The water line construction shall conform to the depth of public health and welfare regulations of public drinking. A minimum of 5-foot cover for water lines water systems and disinfection specifications shall be kept. 14.Fire hydrants or temporary blow-offs shall be installed on dead-end water lines. 15.Water lines shall not exceed 8' in depth from finished grade. 16.At all times, when laying pipe is not in progress, open ends of the pipe shall be closed by a watertight plug or other approved means. At the close of the day's work, or whenever workmen are absent from the job, the end of the last laid section shall be plugged, capped, or tightly closed to prevent entry of foreign material. 17.All water main fittings to be mechanical joint; no flanged fittings. 18.A minimum of 18" vertical clearance must exist between potable and non-potable lines. 19.Fire hydrants shall be Clow Medallion or Waterous Pacer. Any other type shall be up to the CITY OF REXBURG to approve or reject. All fire hydrants shall be painted red. 20.Install No. 12AWG copper locating wire with insulation on all water pipe and water service lines. Utilize epoxy splice kits. SEWER NOTES 1.Prior to construction, it shall be the responsibility of the contractor to inform all the utility companies of the construction schedule. 2.All existing utility locations and depths are approximate and shall be verified by the contractor. 3.All elevations are based on the USED DATUM. 4.Manhole rim elevations as shown on the Construction Drawings are approximate. The manhole frames and covers shall be constructed in accordance with the CITY OF REXBURG Standard Drawings. Rim elevations shall be determined by the engineer in the field during construction. 5.Contractor shall repave any existing paved streets disturbed during construction. 6.Retain and protect all irrigation and drainage crossings. The contractor shall coordinate with the owner and the Rexburg Irrigation Company (208-356-5251) for the inspection of the exposed irrigation and/or drainage pipe crossings. If existing pipes are damaged, the affected pipe will be replaced by the contractor. 7.The developer's engineer shall be present during all testing of the sewer construction. 8.Retain and protect existing curb, gutter and sidewalk. if removal is necessary, replacement shall be incidental to project. 9.The following type and class of pipe will be permitted: gravity pipe shall conform to ASTM D-3034, PVC, SDR 35, or other pipe approved in the CITY OF REXBURG Standards. 10.All work shall be constructed to the CITY OF REXBURG Standards. All work shall be approved by the CITY OF REXBURG. 11.Sanitary sewer manhole cones shall be set a maximum of one (1) foot below specified ring elevations by sewer contractor. All remaining manhole materials, other than concrete collars necessary to construct manhole to finished grade, shall be furnished by the sewer contractor for placement at finished grade by street paving contractor. All materials for concrete around manhole rings shall be supplied and constructed to finished grade by street contractor. The owner's engineer shall be contacted 24 hours prior to placing concrete collars. 12.The trench backfill above the pipe zone will be inspected by the owner's engineer in accordance with the latest edition of the Idaho Standards for Public Works Construction Specifications and the CITY OF REXBURG Standards and Specifications. 13.Where PVC is utilized, a rubber ring or approved equivalent is to be installed where the pipe is in contact with manhole base and/or manhole channel in order to ensure a watertight seal. 14.Where it is necessary for sewer and water to cross each other and the sewer line is above or less than 18 inches below the water main, the sewer line crossing shall be either: a. Non-Potable pipeline construction with potable water class pie for a minimum of ten (10) feet either side of potable pipeline with a single twenty (20) feet section of potable water class pipe centered on the crossing; or b. Sleeve non-potable or potable pipeline with potable water class pipe ten (10) feet either side of crossing. Use of hydraulic cementitous materials such as concrete, controlled density fill, and concrete slurry encasement is not allowed as a substitute for sleeving. If potable pipeline is below non-potable pipeline the non-potable pipeline must also be supported through the crossing to prevent settling. 15.Where the sewer main depth will allow, all sewer service lines shall be constructed to a depth of 9.5' at property line. The contractor shall use 4" diameter PVC pipe or approved equivalent for all service lines. All sewer service lines shall be constructed at a minimum grade of 1%. 16.Sewer service lines shall be 4" PVC and constructed to a point 15' inside the front lot line as shown. Except where otherwise located, the sewer service lines shall be constructed as shown on plan. 17.The horizontal separation of the water and sewer mains shall be a minimum of ten (10) feet. 18.Contractor shall notify the CITY OF REXBURG City Engineer and the developer's engineer 48 hours in advance of construction. 19.Water levels shall be maintained below the trench bottom during the pipe laying and joining operation. The dewatering method shall be discussed with the engineer and approved prior to construction. Ditches and storm drain facilities that are silted up due to the contractor's dewatering shall be cleaned and restored to their original state. 20.Contractor shall locate and protect all underground utilities during construction. 21.The developer shall test the compaction of the sewer pipeline bedding in accordance with the the ISPWC specifications, and will be done by an outside testing laboratory. The cost of this service shall be paid by the developer. However, if the test fails, the cost of the test and any retesting shall be paid by the contractor. The contractor shall coordinate with the developer's engineer and the testing laboratory to schedule the tests, backfilling, and pipe laying operation. 22.After all utilities are constructed and just prior to paving, the contractor shall perform an air test on the sewer system. The developer's engineer shall be present to witness the test.The contractor shall contact the engineer 24 hours prior to testing. City of REXBURG requires low pressure air or hydrostatic testing, mandrel, and CCTV inspection of the completed sewer. 23.The contractor shall leave the excavation for the upstream end of all service lines open for field verification of the invert elevation by the engineer's inspector. The contractor shall not backfill the ends of service lines until he has obtained approval from the engineer's inspector or made other arrangements for verification of service line invert elevations. 24.Service and main piping shall be in accordance with ASTM 3034 and shall be SDR 35 or greater plastic pipe or approved equal. 25.Service wyes shall be installed per the CITY OF REXBURG Standards. 26.Backfill compaction of drop manholes shall not be accepted without full time inspection by developer's engineer during compaction work. 27.At all times, when laying pipe is not in progress, open ends of the pipe shall be closed by a watertight plug or other approved means. At the close of the day's work, or whenever workmen are absent from the job, the end of the last laid section shall be plugged, capped, or tightly closed to prevent entry of foreign material. 28.All visible leaks shall be repaired - even if the leakage is below allowable limits. 29.The developer's engineer shall be present during all testing of the sewer line. 30.A minimum of 18" vertical clearance must exist between potable and non-potable lines. ELECTRICAL NOTES 1.All new electrical facilities shall be constructed in accordance with the current Rocky Mountain Power Service Policy. Each utility shall be constructed to its own policy. 2.Electrical sectionalizing cabinets and bases (when required) will be provided by Rocky Mountain Power but shall be installed by the Developer/Contractor. 3.All primary and secondary conduits shall be provided and installed by the Developer/Contractor. All electrical conduits and 36" radius elbows shall be schedule 40 pvc. 4.The minimum power trench depth shall be 54" below finished grade. (Conduit to be installed 48" below finish grade). Including 6" of sand bedding below and above top of conduits. 5.Primary and secondary conduit depths can be reduced to 18" of cover below finished grade with approval by Rocky Mountain Power. Rigid galvanized steel conduit must be provided and installed by the Developer/Contractor in a trench that is less than 48" deep. 6.The Contractor shall retain and protect all existing City power poles and electrical facilities during construction except those facilities shown to be relocated or moved per Rocky Mountain Power contractors map. 7.Coordinate all electrical construction with Rocky Mountain Power. 8.Owner shall bear all costs to relocate or remove existing power poles, light poles, anchor guys, and miscellaneous electrical facilities, except those facilities inside city rights of way. 9.The Owner/Developer shall provide all trenching, conduit and concrete light pole foundations for street illumination along all Public Right of Way as per Rocky Mountain Power current service policy. In addition, Owner/Developer shall purchase street light assembly provided and installed by Rocky Mountain Power. 10.If applicable, see Rocky Mountain Power Electrical site plan for off-site electrical and fiber optic facilities, layout, and installation details. 11.With exception of conduit crossing, contractor shall install curb and gutter prior to power trench and conduit installation or (with Rocky Mountain Power approval) centerline of trench may be staked with cut/fill to bottom of trench at all grade breaks and hubs at 25' intervals and offset stakes at all transformers, switch cabinets, secondary pedestals etc. 12.Contact Rocky Mountain Power prior to construction. STREET SIGNING 1. All road striping and traffic signing shall be designed, constructed, and placed according to the current Manual of Uniform Traffic Control Devices (MUTCD) with the following exceptions: 1.1.All Stop and Yield signs used in any subdivision shall be a minimum 30" X 30", engineer grade sheeting is not allowed. 1.2.All Road Name and Street signs shall have a minimum 4" legend. Both background and legend shall be retro-reflective. Standard colors are white legend and green background except private roads, which will have a blue background. 1.3.Substrate material shall be aluminum; no fiberglass or plastic will be accepted. 1.4.The minimum size for Speed Limit Signs shall be 24"W X 30"L with black legend on white background. 1.5.Posts shall be metal and shall be anchored with a "soil type" anchor. No concrete shall be used as an anchor. Posts shall be 2" X 2" square and must meet break-a-way standards of the State of Idaho. No U-channel shall be used. 1.6.The minimum height of signs shall be 6' from the road surface to the bottom of the sign. 1.7.Maintenance of all street and traffic signs will be the responsibility of the developer until the streets are officially accepted for maintenance by the CITY OF REXBURG. 4/26/2023 REFERENCES NOTE: NOT ALL HATCHES, LINETYPES, REFERENCES, AND SYMBOLS ON THIS SHEET ARE INCLUDED IN THIS PLAN SET. 404-1.5 INSTALL 1.5" WATER SERVICE 504-4 INSTALL 4" SDR 35 SANITARY SEWER SERVICE @ 2% MIN SLOPE 601-12 INSTALL 12" ADS N 12 STORM PIPE @ 0.22% MIN SLOPE 602-1 602-2 INSTALL CATCH BASIN TYPE I PER DETAIL, SHEET C8.00 706-1 INSTALL 6" STANDARD CURB AND GUTTER PER ISPWC SD - 701, SEE SHEET C9.00 706-R1 INSTALL ADA PEDESTRIAN RAMP W/DETECTABLE WARNING DOMES, SEE ARCHITECT DRAWINGS 706-S2 INSTALL INTEGRAL CONCRETE SIDE WALK, SEE ARCHITECT DRAWINGS INSTALL SD CATCH MANHOLE PER DETAIL, SHEET C8.00 SEWER STORM CONCRETE 1102-1 INSTALL STREET LIGHT PER ELECTRICAL PLANS - BY OTHERS TRAFFIC SIGNAL AND STREET LIGHTING 706-S1 INSTALL 4" CONCRETE SIDEWALK PER ISPWC SD - 709, SEE SHEET C9.00 WATER ACRONYMS BTM BOTTOM BW BOTTOM OF WALL CB STORM DRAIN CATCH BASIN EG EDGE OF GRAVEL EOA EDGE OF ASPHALT EOC EDGE OF CONCRETE FF FINISH FLOOR FG FINISH GRADE GB GRADE BREAK HP HIGH POINT INV IN INVERT IN INV OUT INVERT OUT L LEFT LP LOW POINT OFF OFFSET NTS NOT TO SCALE PC POINT OF CURVATURE PI POINT OF INTERSECTION PUD PLANNED UNIT DEVELOPMENT PUE PUBLIC UTILITY EASEMENT PVI POINT OF VERTICAL INTERSECTION R RIGHT SDMH STORM DRAIN MANHOLE SF SQUARE FEET SSMH SANITARY SEWER MANHOLE STA STATION SW SIDEWALK TBC TOP BACK OF CURB TSW TOP OF SIDEWALK TW TOP OF WALL TOC TOP OF CONCRETE TOA TOP OF ASPHALT VG FL VALLEY GUTTER FLOW LINE LEGEND CONCRETE ASPHALT LANDSCAPING BUILDINGS POND HIGH WATER LINE AND GRADE BREAK HIGH WATER LINE CATCH BASIN FIRE HYDRANT STREET LIGHT VALVE SANITARY SEWER MANHOLE CURB & GUTTER BOUNDARY LINE GRADE BREAK SAW CUT STREET RIGHT-OF-WAY (ROW) EASEMENT LINE FENCE LINE SANITARY SEWER LINE WATERLINE SANITARY SEWER SERVICE WATER SERVICE OVERHEAD POWER GAS LINE SURFACE CONTOUR ASPHALT STORM DRAIN MANHOLE STORM DRAIN LINE POWER POLE SANITARY SEWER MANHOLE POWER POLE STORM DRAIN MANHOLE STREET LIGHT FIRE HYDRANT VALVE LOT LINE CENTERLINE OF ROAD CATCH BASIN UNDERGROUND POWER CURB & GUTTER SANITARY SEWER LINE WATERLINE OVERHEAD POWER SURFACE CONTOUR UNDERGROUND POWER FENCE LINE STORM DRAIN LINE SANITARY SEWER SERVICE WATER SERVICE EXISTING PROPOSED CONCRETE GAS LINE COMMUNICATION COMMUNICATIONS STREET RIGHT-OF-WAY (R/W) EASEMENT LINE LOT LINE GRADE BREAK IRRIGATION IRRIGATION PRESSURE IRRIGATION PRESSUR IRR **ISPWC = IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION** DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : SLH 2022-006 PDH BE E H I V E F C U - N O R T H R E X B U R G 4/26/23 RE F E R E N C E S H E E T C3.00 602-3 INSTALL STORMTECH MC-3500 INFILTRATION CHAMBERS PER SHEET C9.00 504-4C INSTALL 4" CLEANOUT PER DETAIL, SHEET C8.00 706-2 INSTALL 6" VERTICAL PAVEMENT CURB WALL, SEE ARCHITECT DRAWINGS 706-T1 INSTALL CURB TRANSITION, SEE ARCHITECT DRAWINGS APPROVED BY ________________________DATE:____________ City of REXBURG 706-J1 INSTALL CONCRETE JOINT PER ISPWC SD - 714 4/26/2023 DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : SLH 2022-006 PDH BE E H I V E F C U - N O R T H R E X B U R G 4/26/23 EX I S T I N G C O N D I T I O N S C4.00 PROTECT EXISTING ASPHALT PROTECT EXISTING CONCRETE APPROACH PROTECT EXISTING UTILITIES PROTECT EXISTING SIDEWALK PROTECT EXISTING SIDEWALK EXISTING SERVICE STUBS (0.74 AC) 32,440 SQ FT N S A L E M R O A D E MOODY ROAD APPROVED BY ________________________DATE:____________ City of REXBURG 4/26/2023 S0 ° 1 1 ' 0 7 " W 18 2 . 2 5 ' S89° 43' 56"W 178.00' N89° 43' 56"E 178.00' N0 ° 1 1 ' 0 7 " E 18 2 . 2 5 ' 100-1 404-1.5 504-4 601-12 602-1 602-2 706-1 706-S1 SEE SHEET 3 FOR MORE INFORMATION 706-R1 1102-1 SEE SHEET 3 FOR MORE INFORMATION RETAIN AND PROTECT 1.5'' WATER SERVICE 4'' SEWER SERVICE 12'' STORM MAIN STORM MAIN MANHOLE STORM MAIN CATCH BASIN 6'' VERTICAL CURB PEDESTRIAN RAMP 4"' CONCRETE SIDEWALK STREET LIGHT 602-3 STORM INFILTRATION CHAMBERS 504-4C 4'' SEWER SERVICE CLEANOUT 706-T1 CURB TERMINUS 706-J1 CONCRETE JOINT DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : SLH 2022-006 PDH BE E H I V E F C U - N O R T H R E X B U R G 4/26/23 GE N E R A L L A Y O U T C5.00 TRASH PAD & CURB - SEE ARCHITECT DRAWINGS PROPOSED BUILDING PAVE TO EXISTING APPROACH 706-S2 706-S2 N S A L E M R O A D E MOODY ROAD ENTRY SIGN - SEE ARCHITECT DRAWINGS 706-R2 706-1 706-1 706-1 706-1 1102-1 1102-1 1102-1 1102-1 706-R1 10 . 0 0 ' TY P . 20 . 0 0 ' TY P . 25 . 0 0 ' 20 . 0 0 ' 25.00' 5.00' 6. 0 0 ' 53 . 7 7 ' 46.00' 51.61' 25.00' 25.00' 10 . 3 3 ' 12 . 3 3 ' 7.33' 6.50'2.75' 13.75' 11.00'5.00' 68.71' 39 . 3 8 ' 57.28' 84 . 7 7 ' 10.00' PARKING NOTE: PARKING REQUIRED: 9 STALLS (3 / 1000 SQ FT) PARKING PLANNED: 25 STALLS (1 ADA) SITE INFO: TOTAL AREA: 0.74 ACRES (32,440 SQ FT) ZONE: COMMUNITY BUSINESS CENTER (CBC) BUILDING INFO: GROSS FLOOR AREA: 2,676.5 SQ FT BUILDING TYPE: VB BENCHMARK: PP PK NAIL EASTING: 758781.7710 NORTHING: 797683.7030 ELEVATION: 4877.781 706-S2 706-S2 POTENTIAL SNOW STORAGE TRANSFORMER PAD - SEE ARCHITECT DRAWINGS NOTE THIS LAYOUT IS FOR GENERAL PURPOSES ONLY, SEE ARCHITECTURAL SITE PLAN FOR HORIZONTAL CONTROL. 706-2 1' LANDSCAPE CURB AROUND BUILDING EXTERIOR 706-S1 LANDSCAPE CURB - SEE ARCHITECT DRAWINGS LANDSCAPE CURB SEE LANDSCAPE PLAN FOR DETAILS PAVE TO EXISTING APPROACH APPROVED BY ________________________DATE:____________ City of REXBURG BASIS OF BEARING: SEE ARCHITECTURAL PLANS FOR DETAILS 706-J1 706-J1 706-J1 706-J1 706-J1 706-J1 FIELD VERIFY END CONDITIONS 4/26/2023 100-1 404-1.5 504-4 601-12 602-1 602-2 706-1 706-S1 SEE SHEET 3 FOR MORE INFORMATION 706-R1 1102-1 SEE SHEET 3 FOR MORE INFORMATION RETAIN AND PROTECT 1.5'' WATER SERVICE 4'' SEWER SERVICE 12'' STORM MAIN STORM MAIN MANHOLE STORM MAIN CATCH BASIN 6'' VERTICAL CURB PEDESTRIAN RAMP 4"' CONCRETE SIDEWALK STREET LIGHT 602-3 STORM INFILTRATION CHAMBERS 504-4C 4'' SEWER SERVICE CLEANOUT 706-T1 CURB TERMINUS 706-J1 CONCRETE JOINT S0 ° 1 1 ' 0 7 " W 18 2 . 2 5 ' S89° 43' 56"W 178.00' N89° 43' 56"E 178.00' N0 ° 1 1 ' 0 7 " E 18 2 . 2 5 ' Install 78' of 12" ADS N 12 Storm Pipe @ 0.22% Install 78' of 12" ADS N 12 Storm Pipe @ 0.72% 602-1 Install 10' of 12" ADS N 12 Storm Pipe @ 0.22% 602-1 Rim:4878.57 N INV IN:4874.16 S INV IN:4874.66 E INV OUT:4872.10 602-2 GRATE:4878.20 E INV IN:4874.28 S INV OUT:4874.18 602-2 GRATE:4877.53 W INV OUT:4874.45 602-1 GRATE:4876.65 E INV IN:4872.95 SE INV IN:4874.05 N INV OUT:4870.35 Install 75' of 12" ADS N 12 Storm Pipe @ 0.23% 602-2 GRATE:4876.78 SW INV OUT:4873.78 602-2 GRATE:4877.27 NE INV IN:4873.61 N INV IN:4873.61 W INV OUT:4873.51 602-2 GRATE:4877.09 NW INV OUT:4874.09 S0 ° 1 1 ' 0 7 " W 18 2 . 2 5 ' S89° 43' 56"W 178.00' N89° 43' 56"E 178.00' N0 ° 1 1 ' 0 7 " E 18 2 . 2 5 ' DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : SLH 2022-006 PDH BE E H I V E F C U - N O R T H R E X B U R G 4/26/23 UT I L I T Y L A Y O U T C6.00 504-4 404-1.5 TIE IN TO EXISTING SEWER SERVICE FIELD VERIFY EXACT LOCATION TIE INTO EXISTING WATER SERVICE FIELD VERIFY EXACT LOCATION 504-4C 706-S1 RETAIN AND PROTECT EXISTING UTILITIES1102-1 1102-1 1102-1 1102-1 INTERIOR METER AND LANDSCAPE POINT OF CONNECTION. SEE MECHANICAL AND LANDSCAPE PLANS FOR DETAILS. 18' OF 6" PIPE FROM ROOF DRAIN N S A L E M R O A D E MOODY ROAD 504-4C 504-4C 504-4C EX. CATCH BASIN 48' OF 6" PIPE FROM ROOF DRAIN 228' OF 4" SEWER SERVICE 223' OF 1.5" WATER SERVICE 79' ROOF DRAIN, 6" AT 1% MIN. SLOPE APPROVED BY ________________________DATE:____________ City of REXBURG INSTALL WITH SLOTTED LID TIE MANHOLE TO EXISTING STUB, FIELD VERIFY EXACT LOCATION ROOF DRAIN DOWNSPOUTS INV: 4874.46' OR ABOVE COORDINATE WITH ARCH. PLANS ROOF DRAIN DOWNSPOUTS INV: 4874.85' OR ABOVE COORDINATE WITH ARCH. PLANS 602-3 602-3 INSTALL WITH STANDARD LID STORM INFO: TOTAL REQ'D STORAGE: 2,845.5 CU FT TOTAL PLAN STORAGE: 2,954 CU FT RATIONAL METHOD: Q = CIA C = RUNOFF COEFFICIENT i = INTENSITY A = AREA AREA 1: REQ'D STORAGE: 2,031.5 CU FT C = 0.734 i = 1.33 IN/HR A = 24,970 SQ FT PLAN STORAGE: 2,110 CU FT 211 CU FT x 10 MC3500 CHAMBERS AREA 2: REQ'D STORAGE: 814 CU FT C = 0.734 i = 1.33 IN/HR A = 10,005 SQ FT PLAN STORAGE: 844 CU FT 211 CU FT x 4 MC3500 CHAMBERS INFILTRATION RATE: 14.2 IN/HR (FROM GEOTECHNICAL REPORT) TOTAL DEPTH: 45 IN CHAMBER HEIGHT TOTAL INFILTRATION TIME: 3.2 HR --- BOTH AREAS **INSTALL STORMTECH CHAMBERS PER DETAIL, SHEET C10.00 WITH 12" OF ROCK ABOVE AND 9" BELOW CHAMBERS. STORM AREA 1 STORM AREA 2 STORM WATER APPROX. CONTRIBUTING AREAS NTS ROOF DRAIN DOWNSPOUT INV: 4875.51' OR ABOVE COORDINATE WITH ARCH. PLANS 4/26/2023 S0 ° 1 1 ' 0 7 " W 18 2 . 2 5 ' S89° 43' 56"W 178.00' N89° 43' 56"E 178.00' N0 ° 1 1 ' 0 7 " E 18 2 . 2 5 ' -2 . 4 7 % -2 . 6 9 % -2 . 1 9 % -2 . 0 1 % -3 . 4 1 % -2 . 3 8 % - 2 . 0 3 % -2.48 % -2.23% -2.56% -2.84% -3.11% -2.68% -2.48% -2. 3 7 % -3 . 3 7 % -2 . 1 8 % -2 . 1 1 % -2. 4 3 % -2 . 1 3 % -0.76% -0.41% -0 . 4 1 % -0.53% -0.52% -1.90% -1.45% -3 . 1 5 % -2.23% -2. 2 5 % -1. 9 6 % 487 8 487 8 48 7 8 4 8 7 8 4877 4877 4878 4879 4879 48 7 9 48 7 9 48 7 8 4878 487 8 -0 . 4 0 % - 2 . 0 0 % -2 . 0 0 % -0.58% -0.59% -2.59% -2.93%-2.79% 48 7 9 -2. 0 2 % -4.75% -17.73% -7.72% - 1 1 . 6 2 % -2.00% - 1 . 9 2 % -0 . 9 8 % 487 7 -3.70% 4878.26 TBC-PI 4878.03 TBC-PI 4878.15 TBC-PI 4877.93 TBC-PI 4878.15 TBC 4878.00 TBC 4877.30 TBC-PC 4877.57 TBC-PC 4878.87 TBC-HP 4878.70 TBC-LP 4878.86 TBC-HP 4877.77 TBC-LP 4879.34 TBC-PI 4879.36 TBC END 4879.32 TBC END 4879.45 TSW4879.69 TSW 4879.69 TSW 4879.42 TSW 4879.44 TSW 4879.46 TSW 4879.38 TSW 4879.42 TSW 4879.67 TSW 4879.67 TSW 4879.75 TSW 4879.75 TSW 4879.75 TSW 4878.77 TOA 4878.77 TSW 4878.77 TSW 4879.22 TSW 4879.28 TSW 4879.32 TSW 4879.40 TSW 4879.51 TSW 4878.77 TSW 4879.26 TSW 4879.35 TSW 4878.77 TOA 4878.76 TOA 4878.85 TOA 4878.77 TOA 4878.72 TOA 4878.78 TOA 4878.82 TOA 4878.90 TOA 4878.99 TOA 4879.75 FF 4878.74 EXIST 4878.49 EXIST 4877.90 EXIST 4876.78 EXIST 4876.73 EXIST 4877.67 TBC END 4877.69 TBC END 4877.54 TBC END 4877.29 TBC END 4877.93 TBC 4877.95 TBC-PI 4877.27 TBC-LP 4879.75 TSW 4879.75 TSW 4879.75 TSW 4879.68 TSW 4879.75 TSW4879.73 TSW 4879.67 TSW 4879.57 TSW 4876.37 EXIST 4877.33 EXIST 4878.38 TBC-HP 4877.49 TBC END 4879.75 TBC 4878.03 TSW 4878.06 TSW 4877.83 TSW 4878.01 TSW 4879.01 ISLAND TOP 4878.52 ISLAND TOP 4878.63 TOC 4878.51 TOC 4878.28 TOC 4878.40 TOC 4878.13 TOC 4878.02 TOC 4878.51 TOC 4878.63 TOC 4878.40 TOC 4878.13 TOC 4878.28 TOC 4878.02 TOC 4877.15 TBC-LP 4877.32 TBC-PI 4877.16 EXIST 4876.61 EXIST 4879.48 TBC-PC 4878.46 TSW-MATCH 4878.46 TSW-MATCH 4877.82 TBC 4879.13 ISLAND TOP 4878.40 ISLAND TOP 4878.78 ISLAND TOP 4878.13 ISLAND TOP 4879.58 TSW 4879.08 TOA 4878.85 TOA 4878.75 TOA 4878.90 TOA 4879.07 TOA 4879.07 TOA 4878.90 TOA 4879.50 TSW 4879.50 TSW 4879.40 TSW 4879.57 TSW 4879.40 TSW4879.57 TSW 4879.58 FG 4879.59 FG 4879.58 FG 4879.58 FG 4879.58 FG 4879.58 FG 100-1 404-1.5 504-4 601-12 602-1 602-2 706-1 706-S1 SEE SHEET 3 FOR MORE INFORMATION 706-R1 1102-1 SEE SHEET 3 FOR MORE INFORMATION RETAIN AND PROTECT 1.5'' WATER SERVICE 4'' SEWER SERVICE 12'' STORM MAIN STORM MAIN MANHOLE STORM MAIN CATCH BASIN 6'' VERTICAL CURB PEDESTRIAN RAMP 4"' CONCRETE SIDEWALK STREET LIGHT 602-3 STORM INFILTRATION CHAMBERS 504-4C 4'' SEWER SERVICE CLEANOUT 706-T1 CURB TERMINUS 706-J1 CONCRETE JOINT S0 ° 1 1 ' 0 7 " W 18 2 . 2 5 ' S89° 43' 56"W 178.00' N89° 43' 56"E 178.00' N0 ° 1 1 ' 0 7 " E 18 2 . 2 5 ' DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : SLH 2022-006 PDH BE E H I V E F C U - N O R T H R E X B U R G 4/26/23 GR A D I N G C7.00 N S A L E M R O A D E MOODY ROAD STORM AREA 1 STORM AREA 2 STORM WATER APPROX. CONTRIBUTING AREAS- SEE C6.00 NTS 706-1 706-1 706-1 706-1 706-R2 706-R1 WEEP HOLE - SEE ARCH. PLANS ENSURE FINISH GRADE SLOPES AWAY FROM BUILDING APPROX. ADJACENT TBC, EXISTING 706-T1 706-T1 706-T1 706-T1 ENSURE LANDSCAPE CURB WALL IS INSTALLED WITH SUFFICIENT BURY DEPTH EACH SIDE APPROVED BY ________________________DATE:____________ City of REXBURG ENSURE FINISH GRADE SLOPES AWAY FROM BUILDING ELEVATIONS UPDATED4-26-23 4/26/2023 *See Landscape Plans for all Landscape Final Grades Throughout Minor Grade Adjustments SANITARY SEWER MANUFACTURUER MANUFACTURUER XXXX XX / XX DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : SLH 2022-006 PDH BE E H I V E F C U - N O R T H R E X B U R G 4/26/23 DE T A I L S C8.00 30" 17" 3. 1- 3 4" X 1- 3 4" X 1 4" STEEL ANGLE SEE NOTES BELOW. 1- 1 2" 3 4 " T Y P . SET 13 TRANSVERSE BARS AT 45 DEGREES. 29- 3 4" 15- 1 4" 3 4" 16- 3 4" 2.1. CATCH BASIN GRATE TYPE I ISPWC SD-609 NTS NOTES A.FOUR-SIDED FRAME IS REQUIRED. B.CONTRACTOR HAS THE OPTION OF WELDING THE BACK STEEL ANGLE BAR INTO PLACE AFTER SLIP FORMS FOR BOX HAVE BEEN REMOVED. ENSURE GRATE FRAME IS SQUARE BEFORE DOING A FULL PENETRATION WELD TO ATTACH BACK STEEL ANGLE BAR. LEGEND 1.1- 1 2" X 3 4" STEEL BARS (TYP.) 2.1 4" FILLET WELD ALL BARS 4 PLACES (TYP.) 3.WELD (4) 1 2" X 3 STUDS. STANDARD CONCRETE CATCH MANHOLE ISPWC SD-611 NTS 6" ( M I N . ) 21 " ( M A X . ) 4" (MIN.) 12"24" DIA. 36" (MAX.)24" (MIN.) 12" 2' (MIN.) 48" 16" (MAX.)6" (MIN.) 4" T Y P E 1 BE D D I N G 10. 9.8. 1. 2. 3. 4. 5. 6. 6.11. 12. EX T E N D P I P E ( 1 " T O 6 " M A X . ) IN S I D E M A N H O L E PIPE FROM INLETS AND/OR TEE IN MAIN LINE. 7. 11. LEGEND 1.CONCRETE COLLAR IN PAVED STREET SECTIONS PER DETAIL, THIS SHEET. 2.GRADE RINGS GROUTED WATERTIGHT IN PLACE, NOT TO EXCEED 21" FROM FINISHED SURFACE TO TOP OF CONE. 3.PRECAST MONOLITHIC ECCENTRIC CONE SECTION. (REBAR NOT SHOWN). 4.RAMNEK OR APPROVED GASKETS AT ALL JOINTS. 5.PROPERLY ALIGN ALL INTERIOR JOINTS. 6.PRECAST CONCRETE MANHOLE BARREL SECTION (REBAR NOT SHOWN). 7.PRECAST GASKETED HUB RING OR RUBBER GASKETED COLLAR. 8.SURFACING TO MATCH FLUSH WITH EXISTING SURFACING (AS SHOWN). 9.FRAME TO GE GROUTED TO GRADE RINGS. 10.FRAME AND COVER PER DETAIL, THIS SHEET 11.MANHOLE STEPS. SEE NOTE G. 12.SEE SD-501 FOR CAST IN PLACE MANHOLE BASE. SEE SD-501A FOR PREFABRICATED BASE. NOTES A.OPTIONAL PREFABRICATED MANHOLE BASE WITH APPROVED PIPE CONNECTIONS MAY BE USED WITH ENGINEERS APPROVAL, SEE SD-501A. B.PLACE VERTICAL WALL ON UPSTREAM SIDE OF MANHOLE, ROTATED 45 DEGREES. C.FOR INLET PIPE DIAMETER, D, GREATER THAN 24" SEE SD-613 OR SD-614. D.MANHOLE FRAME AND COVER: D.A.REFER TO DRAWING NO. SD-617. D.B.FRAME AND COVER SHALL BE FLUSH WITH SLOPE OF PAVEMENT. D.C."STORM DRAIN" ON COVER. E.WHERE PVC PIPE IS UTILIZED, INSTALL A RUBBER RING OR GASKET COLLAR WHERE THE PIPE IS IN CONTACT WITH MANHOLE BASE AND/OR MANHOLE CHANNEL, IN ORDER TO INSURE A WATERTIGHT SEAL. F.EITHER BASE ON SD-501 OR SD-501A MAY BE USED WITH EITHER MANHOLE DESIGN. G.VERIFY WITH ENGINEER REGARDING LOCAL PREFERENCE ON INSTALLATION OF MANHOLE STEPS PRIOR TO ORDERING ON INSTALLATION OF MANHOLE STEPS PRIOR TO ORDERING MATERIALS OR INSTALLATION. 1. 2. 3. 4. SANITARY SEWER 1'- 0" 6" 5. 6.7. 8.9. 8" 2'- 0" OR 2'- 6" NOTES A.TOP OF COLLAR TO BE FLUSH WITH MANHOLE COVER. MANHOLE COLLAR SD-508 LEGEND 1.#4 REBAR HOOPS (2 EACH) SEE SECTION A-A). 2.#4 REBAR AT 20" SPACING. 3.SCORES. 4.RIM. 5.FRAME AND COVER PER SD-507 AND SD-507A. 6.SEE "DETAIL A" FOR REBAR IN COLLAR. 7.FINISHED GRADE. 8.SEE OTHER STANDARD DRAWINGS OF MANHOLES FOR MAXIMUM HEIGHT. 9.GROUT BETWEEN RING AND COVER AND GRADE RINGS. 10.FRIBILLATED POLYPROPYLENE FIBER (ADDED PER MANUFACTURER'S RECOMMENDATIONS) MAY BE USED IN LIEU OF #4 REBAR IN CONCRETE COLLARS. 1 8" - 1 4" 6" 2" ( M I N ) 7. 10. PLAN COVER FRAME COVER 1" HOLES (4 EACH AT 90 DEGREES) MINIMUM LETTERING HEIGHT OF 1", MOLDED INTO TOP OF COVER. 1 2" GUSSETS (6 EACH @60 DEGREES) 23 7 8"1" 7 8" PLATEN BOTTOM COVER 25 1 2" 24" 1" 6" 22 1 2" 30" 5" NOTES A.MANHOLE FRAMES AND COVERS TO HAVE A TOLERANCE OF 1 4" OR LESS. B.COVERS NOT TO BE WARPED. REPLACE ALL THAT RATTLE OR VIBRATE WHEN TRAVELED UPON. MACHINE ALL MATCHING SURFACES. C.MINIMUM WEIGHT OF FRAME AND COVER = 265 LBS. STANDARD MANHOLE COVER AND FRAME SD-507 ASPHALT PARKING LOT SECTION 4" DEPTH CRUSHED 3 4" MINUS AGGREGATE LEVELING COURSE COMPACTED TO 95% ASTM D698 12" DEPTH UNCRUSHED AGGREGATE SUBBASE COURSE COMPACTED TO 95% ASTM D698 SUBGRADE EARTH COMPACTED TO 95% ASTM D698 3" DEPTH ASPHALT PLANT MIX - PAVE IN TWO LIFTS CONCRETE DRIVE THRU SECTION 6" DEPTH CRUSHED 3 4" MINUS AGGREGATE LEVELING COURSE COMPACTED TO 95% ASTM D698 12" DEPTH UNCRUSHED AGGREGATE SUBBASE COURSE COMPACTED TO 95% ASTM D698 SUBGRADE EARTH COMPACTED TO 95% ASTM D698 5" DEPTH RIGID CONCRETE INLET CATCH BASIN TYPE I ISPWC SD - 601 NTS 4" SEWER CLEANOUT ISPWC SD - 506A NTS APPROVED BY ________________________DATE:____________ City of REXBURG 6 x 6 WELDED WIRE FABRIC PLACED AT MID-DEPTH 4/26/2023 DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : SLH 2022-006 PDH BE E H I V E F C U - N O R T H R E X B U R G 4/26/23 DE T A I L S 2 C9.00 6" VERTICAL CURB ISPWC SD - 701 NTS CONCRETE SIDEWALK ISPWC SD - 709 NTS APPROVED BY ________________________DATE:____________ City of REXBURG 4/26/2023 DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : SLH 2022-006 PDH BE E H I V E F C U - N O R T H R E X B U R G 4/26/23 ST O R M T E C H D E T A I L S C10.0 4/26/2023 S0 ° 1 1 ' 0 7 " W 18 2 . 2 5 ' S89° 43' 56"W 178.00' N89° 43' 56"E 178.00' N0 ° 1 1 ' 0 7 " E 18 2 . 2 5 ' POTENTIAL POLLUTANTS CHEMICAL MSDS #LOCATION TO BE FILLED OUT BY CONTRACTOR TO BE FILLED OUT BY CONTRACTOR OFFSITE OPERATONS START DATE END DATE TO BE FILLED OUT BY CONTRACTOR AREA TO BE DISTURBED STABILIZE CONSTRUCTION ENTRANCE/EXIT COMBINATION STAGING AREA & VEHICLE EQUIPMENT CLEANING, FUELING AND MAIN. MATERIALS STORAGE AREA & STOCKPILE MANAGEMENT SILT FENCE OR STRAW WATTLE STORM WATER DRAINAGE SEQUENCE OF MAJOR ACTIVITIES ACTIVITY START DATE END DATE POTENTIAL POLLUTANTS CHEMICAL MSDS #LOCATION TO BE FILLED OUT BY CONTRACTOR TO BE FILLED OUT BY CONTRACTOR OFFSITE OPERATONS START DATE END DATE TO BE FILLED OUT BY CONTRACTOR BEST MANAGEMENT PRACTICES NOTES 1. This plan should be revised and updated to address changes in site conditions, new or revised government regulations, and additional on-site storm water pollution. Additional erosion control measures may be required. 2. All revisions to this plan must be documented on the SWPPP Revision Documentation Form. 3. Current versions of the SWPPP, the NOI, and the NOC will be kept on site for the duration of the project. These items will be available for the use of all operators and site personal involved with erosion and sediment controls, and be available to EPA visiting the site. A notice will be posted near the construction entrance during construction, containing the SWPPP, the NOI and the NOC. 4. Fugitive dust blowing from the site shall be controlled by spraying water and dust control polymers as needed on dry areas of the site. 5. The contractor will be responsible for supervision and inspection of all erosion and sedimentation controls and for ensuring the SWPPP is implemented. 6. Prior to beginning earth-moving activities, including clearing and grubbing, all clearing limits, easements, setbacks, sensitive areas and their buffers will be clearly marked to prevent environmental damage both on and off the site. 7. If sediment is accidentally transported on to the street it will be removed from the street surface on a daily basis. 8. All off-site construction shall be stabilized at the end of the working day. 9. All waste material will be collected and stored in a securely lidded dumpster. The dumpster will meet all local and state solid water management regulations. 10. Portable sanitary units will be provided for use by all workers for the entire project. Sanitary waste will be collected regularly for the portable units by an approved sanitary waste management contractor. 11. All exposed soils will be stabilized with vegetation or covered no more than 14 days after the construction activity in that portion of the site has temporarily or permanently ceased. 12. Existing and new vegetation will be maintained to the maximum extent practicable to prevent the contamination of storm water with sediment. 13. The contractor shall be responsible for adjusting the erosion control measure; due to grade changes during the development of the project. 14. Maintain on the site or have readily available sufficient oil and grease absorbing materials to contain and clean up fuel or chemical spills and leaks. 15. Adequate energy dissipation, erosion control, and soil stabilization measures will be provided for all point source discharges of storm water, including run-on discharges and outlets for onsite discharges. 16. Temporary and permanent swells and small detention ponds will be used as necessary to reduce the velocity of runoff and enhance particle settling. 17. Consistent with the general permit requirements, all potential pollutants other than sediment will be handled and disposed of in a manner that does not affect contamination of stormwater. 18. Materials used during construction with the potential to impact storm water, will be stored, managed, used, and disposed of in a manner that minimizes the potential for releases to the environment and especially in the storm water. 19. If a spill of pollutants threatens storm water at the site, the spill response procedures must be implemented in a timley manner to prevent the release of pollutants. 20. All temporary and permanent erosion and sediment control BMPs will be maintained and repaired as needed to assure continued performance of their intended use. 21. All temporary erosion control and sediment control BMPs will be removed within 30 days after final site stabilization is achieved or after the temporary BMPs are no longer needed. 22. Regardless of recommended maintenance schedule, all control measures and inspections shall be performed within 24 hours following any storm of 0.5 inches or greater. An inspection report shall be kept at all times and should be retained for at least three (3) years from the date the site is stabilized. 23. All contractors providing services on the project which may cause storm water pollution will be given a copy of the SWPPP and appropriate training regarding stormwater pollution prevention. LEGEND Concrete Washout SEDIMENTATION AREA CONCRETE WASHOUT INLET PROTECTION INLET PROTECTION INLET PROTECTION MATERIAL STORAGE AREA COMBINATION STAGING AREA & VEHICLE FUEL & CLEANING STABILIZE CONSTRUCTION ENTRANCE/EXIST AREA TO BE DISTURBED SILT FENCE OR STRAW WATTLE Concrete Washout CONCRETE WASHOUT AREA SEDIMENTATION AREA THIS IS NOT A FULL SWPPP. CONTRACTOR IS RESPONSIBLE FOR A COMPLETE SWPPP NOTE: 1.AFTER ASPHALT PAVING HAS TAKEN PLACE STORM WATER DEVELOPED WILL BE DIRECTED TO RETENTION BASINS AND PIPING PER THE APPROVED SITE PLAN AND PERCOLATE IN DESIGNATED AREAS 2.INLET PROTECTION TO BE PLACED ON ALL STORM DRAIN INLETS AFTER INSTALLATION THROUGH THE DURATION OF THE PROJECT. CONTRACTOR RESPONSIBLE TO REMOVE AFTER CITY ACCEPTANCE. INLET PROTECTION INLET PROTECTION OUTHOUSE SWPPP SIGN SWPPP PROJECT: CONTRACTOR: PLAN LOCATION: ONSITE CONTACT: SWPPP PROJECT: CONTRACTOR: PLAN LOCATION: CONTACT: DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : SLH 2022-006 PDH BE E H I V E F C U - N O R T H R E X B U R G 4/26/23 ER O S I O N C O N T R O L C11.0 4/26/2023 1 L1.5 2 L1.5 3 L1.5 4 L1.5 4 L1.5 5 L1.5 TYP. TYP. TYP. TYP. TYP. TYP. 3 L1.5 DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . N E W B U I L D I N G F O R : BE E H I V E F C U - N O R T H R E X B U R G 22021 BLD #23014 MARCH 2023 JB CP RE X B U R G , I D A H O 8 3 4 4 0 ww w . b r e c k o n l a n d d e s i g n . c o m Fa x : 2 0 8 - 3 7 6 - 6 5 2 8 Ph o n e : 20 8 - 3 7 6 - 5 1 5 3 66 6 1 N o r t h G l e n w o o d S t r e e t Ga r d e n C i t y , I d a h o 8 3 7 1 4 CA L L 2 B U S I N E S S D A Y S IN A D V A N C E B E F O R E YO U D I G , G R A D E , O R EX C A V A T E F O R T H E MA R K I N G O F UN D E R G R O U N D ME M B E R U T I L I T I E S Ca l l b e f o r e y o u d i g . Kn o w w h a t ' s b e l o w . R  I69: ÑKFÑJBFG: Ñ ÄÑ>EÑ;>IJKѤŽ–• DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . N E W B U I L D I N G F O R : BE E H I V E F C U - N O R T H R E X B U R G 22021 BLD #23014 MARCH 2023 JB CP RE X B U R G , I D A H O 8 3 4 4 0 ww w . b r e c k o n l a n d d e s i g n . c o m Fa x : 2 0 8 - 3 7 6 - 6 5 2 8 Ph o n e : 20 8 - 3 7 6 - 5 1 5 3 66 6 1 N o r t h G l e n w o o d S t r e e t Ga r d e n C i t y , I d a h o 8 3 7 1 4 CA L L 2 B U S I N E S S D A Y S IN A D V A N C E B E F O R E YO U D I G , G R A D E , O R EX C A V A T E F O R T H E MA R K I N G O F UN D E R G R O U N D ME M B E R U T I L I T I E S Ca l l b e f o r e y o u d i g . Kn o w w h a t ' s b e l o w . 5 127(6 3(5(11,$/ *5281'&29(5 3/$17,1* 6(&7,21 3/$1 9,(:  6+58% 3/$17,1* '(&,'8286 75(( 3/$17,1* (;758'(' &21&5(7( ('*,1* %28/'(5 ,167$//$7,21 POC 2" 3"3" 112" 3" 3"3" 8" 3 L2.6 TYP. 17 L2.5 TYP. 2 L2.6 TYP. 8 L2.5 TYP. 15 L2.5 TYP. 16 L2.5 TYP. 5 L2.57 L2.5 3 L2.5 TYP. 10 L2.5 TYP. 4 L2.5 TYP. CSS D FS E E E E E E E D C SS FS POC 8" DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . N E W B U I L D I N G F O R : BE E H I V E F C U - N O R T H R E X B U R G 22021 BLD #23014 MARCH 2023 JB CP RE X B U R G , I D A H O 8 3 4 4 0 ww w . b r e c k o n l a n d d e s i g n . c o m Fa x : 2 0 8 - 3 7 6 - 6 5 2 8 Ph o n e : 20 8 - 3 7 6 - 5 1 5 3 66 6 1 N o r t h G l e n w o o d S t r e e t Ga r d e n C i t y , I d a h o 8 3 7 1 4 CA L L 2 B U S I N E S S D A Y S IN A D V A N C E B E F O R E YO U D I G , G R A D E , O R EX C A V A T E F O R T H E MA R K I N G O F UN D E R G R O U N D ME M B E R U T I L I T I E S Ca l l b e f o r e y o u d i g . Kn o w w h a t ' s b e l o w . R IRRIGATION NOTES SYSTEM OPERATIONAL NOTES DRIP IRRIGATION NOTES DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . N E W B U I L D I N G F O R : BE E H I V E F C U - N O R T H R E X B U R G 22021 BLD #23014 MARCH 2023 JB CP RE X B U R G , I D A H O 8 3 4 4 0 ww w . b r e c k o n l a n d d e s i g n . c o m Fa x : 2 0 8 - 3 7 6 - 6 5 2 8 Ph o n e : 20 8 - 3 7 6 - 5 1 5 3 66 6 1 N o r t h G l e n w o o d S t r e e t Ga r d e n C i t y , I d a h o 8 3 7 1 4 CA L L 2 B U S I N E S S D A Y S IN A D V A N C E B E F O R E YO U D I G , G R A D E , O R EX C A V A T E F O R T H E MA R K I N G O F UN D E R G R O U N D ME M B E R U T I L I T I E S Ca l l b e f o r e y o u d i g . Kn o w w h a t ' s b e l o w . 5 0$18$/ /,1( )/86+,1* 9$/9( 3/80%(' 72 78%,1* 127( 7(&+/,1( 67$57 &211(&7,21 7(&+/,1( 68%*5$'( ,167$//$7,21 75(1&+ 6(&7,21 48,&. &283/(5 9$/9( (&2 ,1',&$725 635$< +($' 32383 635,1./(5 62/$5 6<1& ,167$/$7,21 ,62/$7,21 9$/9( $8720$7,& ,55,*$7,21 &21752//(5 127(  127( 7(&+/,1( /$<287 127( '5,3/,1( /$<287 $7 75((6 )/2: 6(1625 127(  )/2: 6(1625 $1' 0$67(5 9$/9( /$<287 127(  127( 0$18$/ '5$,1 9$/9( 52725 32383 635,1./(5 0$67(5 9$/9( 127(  DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . N E W B U I L D I N G F O R : BE E H I V E F C U - N O R T H R E X B U R G 22021 BLD #23014 MARCH 2023 JB CP RE X B U R G , I D A H O 8 3 4 4 0 ww w . b r e c k o n l a n d d e s i g n . c o m Fa x : 2 0 8 - 3 7 6 - 6 5 2 8 Ph o n e : 20 8 - 3 7 6 - 5 1 5 3 66 6 1 N o r t h G l e n w o o d S t r e e t Ga r d e n C i t y , I d a h o 8 3 7 1 4 CA L L 2 B U S I N E S S D A Y S IN A D V A N C E B E F O R E YO U D I G , G R A D E , O R EX C A V A T E F O R T H E MA R K I N G O F UN D E R G R O U N D ME M B E R U T I L I T I E S Ca l l b e f o r e y o u d i g . Kn o w w h a t ' s b e l o w . 5 5(027( &21752/ 9$/9( :,7+  ),/7(5 127(  5(027( &21752/ 9$/9( 127(  +$5'6&$3( &5266,1* 75(1&+ 6(&7,21 127(  20 ' - 0 " 25 ' - 0 " 20 ' - 0 " 46'-6"66'-6"25'-0"20'-0" (TYP.) 9'-5" 8' - 7 " 26'-0"26'-0" 67 ' - 5 " 20 ' - 0 " 86'-6" 158'-0" 10 ' - 0 " 10 ' - 1 0 " 10'-0" 10'-7" 6' - 0 " 5' - 0 " 8' - 1 0 " 10'-0" 35 ' - 6 " 36 ' - 0 " 5' - 0 " 22 ' - 0 " 65 ' - 7 1 / 2 " 12 ' - 4 " 10 ' - 0 " (T Y P . ) R 7 . 5 ' R7.5 ' 6' - 0 " 6'-0" 6' - 6 " 15'-6" 9'-0"2'-0"9'-0"2'-0"9'-0"3'-6"10'-0" 32 ' - 2 " 1' - 1 1 " 1' - 1 1 " 4'-0" (TYP.) 19'-6" 15 ' - 8 " 12'-10"8'-1 1/2" 5'-0" 6'-6"11'-0" (VAN) 5'-0" 13'-9" 24 " 30 " 30 " 10'-0"4'-0"10'-0" 10'-0" R 1 0 . 0 ' SI T E P L A N - H O R I Z O N T A L C O N T R O L DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : GLN 22021 APRIL 2023 CJR 04 - 0 6 - 2 0 2 3 NSCALE: SITE PLAN 1" = 10'-0"SP1.1 1 City Plan Review 4/21/23 DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : GLN 22021 APRIL 2023 CJR 04 - 0 6 - 2 0 2 3 SP2.1 SI T E D E T A I L S DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : GLN 22021 APRIL 2023 CJR 04 - 0 6 - 2 0 2 3 SP2.2 SI T E D E T A I L S CJR SCALE:1/2" = 1'-0"SCALE:3/16" = 1'-0" SCALE: SCALE:1/2" = 1'-0" SCALE:N.T.S.SCALE:N.T.S.SCALE:N.T.S. NOTE 2 LANDING NOTE 2 CONCRETE CURBNOTE 1 5 % M A X . D N 5% M A X . DN SCALE:SCALE: SCALE:N.T.S. SCALE:1 1/2" = 1'-0" SCALE: DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : GLN 22021 APRIL 2023 CJR 04 - 0 6 - 2 0 2 3 SP2.3 SI T E D E T A I L S 1 City Plan Review 4/21/23 6.4A 6.6B4.4A 6.6C 6.6D 6.6E 6.6F 6.6G 6 3/4"4 3/4" BRICK VENEER 3/4" AIR SPACE 7/16" WOOD SHEATHING U.N.O. IN DETAILS 3 5/8" 1 1/4" 4 7/8" 5/8" GYPSUM BOARD 2X4 WOOD STUDS 5/8" GYPSUM BOARD 2X6 WOOD STUDS 5/8" GYPSUM BOARD 2X6 WOOD STUDS BRICK VENEER AIR SPACE 3 5/8" 1 1/8" 6 5/8" 11 3/8" AIR BARRIER R-21 INSULATION VAPOR BARRIER 5/8" GYPSUM BOARD 2X6 WOOD STUDS MANUFACTURED STONE VENEER AIR SPACE AIR BARRIER R-21 INSULATION VAPOR BARRIER 3 5/8" 1 1/8" 6 5/8" 11 3/8" 2X6 WOOD STUDS MANUFACTURED STONE VENEER AIR SPACE AIR BARRIER R-21 INSULATION VAPOR BARRIER 1'-3 5/8" 3 5/8" 15/16" 6 1/2" 15/16" 3 5/8" INTERIOREXTERIOR 2X6 WOOD STUDS BRICK VENEER AIR SPACE AIR BARRIER R-21 INSULATION VAPOR BARRIER INTERIOREXTERIOR 3 5/8" 15/16" 6 1/2" 15/16" 3 5/8" 1'-3 5/8" 2X6 WOOD STUDS BRICK VENEER AIR SPACE AIR BARRIER R-21 INSULATION VAPOR BARRIER INTERIOREXTERIOR MANUFACTURED STONE VENEER 3 5/8" 15/16" 6 1/2" 15/16" 3 5/8" 1'-3 5/8" 7/16" WOOD SHEATHING 5.6A BRICK VENEER AIR SPACE 3 5/8" 6 3/8" 10" 6" CMU MANUFACTURED STONE VENEER AIR SPACE 6" CMU 5.6B 6.6B 7 1/4" 5/8" GYPSUM BOARD 2X6 WOOD STUDS 7/16" SHEATHING - SEE STRUCTURALTILE OVER 5/8" BACKER BOARD - WHERE OCCURS TILE OVER 5/8" BACKER BOARD - WHERE OCCURS 3 5/8" 6 3/8" 10" 7/16" WOOD SHEATHING 7/16" WOOD SHEATHING 7/16" WOOD SHEATHING 7/16" WOOD SHEATHING R-21 INSULATION R-21 INSULATIONR-15 INSULATION R01 5/8" GYPSUM BOARD VAPOR BARRIER FILLED WITH BATT INSULATION - R-49 MIN. OPEN WEB BARREL WOOD TRUSS 5/8" SHEATHING STANDING SEAM METAL ROOF - RADIUS ROOFING UNDERLAYMENT R02 5/8" GYPSUM BOARD VAPOR BARRIER FILLED WITH INSULATION - R-49 MIN. ROOF JOIST 5/8" SHEATHING STANDING SEAM METAL ROOF ROOFING UNDERLAYMENT R03 PRE-FINISHED METAL SOFFIT WOOD TRUSS 1/2" COVER BOARD SINGLE PLY MEMBRANE 5/8" WOOD SHEATHING 1/2" WOOD SHEATHING R04 1/2" GYPSUM BOARD VAPOR BARRIER FILLED WITH IGNITION BARRIER SPRAY FOAM INSULATION - R-49 MIN. 9 1/2" TJI ROOF JOIST 5/8" SHEATHING STANDING SEAM METAL ROOF ROOFING UNDERLAYMENT I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 3 : 5 2 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A1.0 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . WA L L A N D R O O F T Y P E S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE:1 1/2" = 1'-0" WALL TYPES SCALE: 1 1/2" = 1'-0" ROOF TYPE WALL TYPES MAY NOT BE CONSISTENT ACROSS THE FULL LENGTH OR HEIGHT OF EACH WALL. SEE WALL TAGS, ELEVATIONS, AND WALL SECTIONS FOR EACH WALL TO DETERMINE FINAL HORIZONTAL AND VERTICAL SUBSTRATE TRANSITIONS AND WALL FINISHES. SHEATHING THICKNESS CALLED FOR BY STRUCTURAL DRAWINGS SHALL GOVERN. VERIFY WALL SIDE INSTALLATION WITH SHEET S2.1 AND S2.2. 66 44 33 11 22 A A B B DE E 55 C AA AA BB BB CC CC 3.5 4.8 1.5 9'-0" 1'-0" 1'-0" 9'-0" 1'-0" 1'-0" 9'-0" 1'-10" 1'-8" BREAK 107 OFFICE 1 104 MECH. 111 JAN./STOR. 112 MANAGER 103 HALLWAY 108 DRIVE-THRU 106OFFICE 2 113 3'-11" 14'-0" 12'-2" 7'-4" 13'-4" 11'-5 1/4" 11'-0" 11'-10" 14 ' - 1 3 / 4 " 4 ' - 1 0 " 1 0 ' - 8 " 1 1 ' - 0 " 1 2 ' - 1 " 6 ' - 7 " 11'-10"11'-0"11'-5 1/4"13'-4"5'-5 1/4"8'-0"8'-8"11'-4 3/4" 12 ' - 1 " 1 1 ' - 0 " 1 0 ' - 8 " 4 ' - 1 0 " 1 4 ' - 1 3 / 4 " 34'-3 1/4"46'-10" 6.6B 6.6B 6.6B 5 1/4" 14'-10 3/4"3'-4" 1'-4 1/2" 15'-10"11'-7 1/2" 5 1 / 4 " 2' - 6 3 / 4 " 2 ' - 4 " 3 ' - 0 " 9 ' - 1 " 1 0 ' - 0 " 3 ' - 4 1 / 4 " 3 ' - 0 " 8 ' - 0 " 3 ' -0 " 8 ' - 4 3 / 4 " 7 1 / 4 " 9' - 8 3 / 4 " 1 4 ' - 4 " 1 4 ' - 4 " 1 4 ' - 4 " 8 3 / 4 " 10 ' - 7 " 5.6A OFFICE 3 115 I.T. 116 TOILET 117 TOILET 118 8" 8 " 1 3 ' - 0 " 8 " 8 " 1 3 ' - 0 " 8 " 8 " 8"8"10'-6"8"8"9'-8"8"8"10'-4" MAIN LOBBY 102 FA C E O F S T U D 52 ' - 8 3 / 4 " 52 ' - 8 3 / 4 " FACE OF STUD 2'-0"2'-0" 1' - 4 " 7 ' - 1 0 " 4 ' - 1 1 3 / 4 " 7 ' - 1 0 " 1 ' - 4 " 2'-0"2'-0" 10'-3" 34'-3 1/4"46'-10" 6.6B 6.4A 6.4A 6.4A 6.4A 6.4A 6.6B 6.6B 6.6B 6.6B 6.6B 6.6B 6.6C 6.6D 6.6C 5.6A 5.6A 9' - 5 " 5 ' - 2 1 / 4 " 2 ' - 2 3 / 4 " 1 1 ' - 1 1 " 1' - 5 " 9' - 1 0 " 1' - 5 " 6.6F 10 ' - 2 " 3' - 7 " 6 ' - 7 " FACE OF STUD FA C E O F S T U D FA C E O F S T U D FA C E O F S T U D FACE OF STUD 6.6C 6.6C4' - 0 " FACE OF STUD 9'-0" 13'-4 1/2"5'-5 1/4" 1'-4"6'-8" 8'-4 1/4"2'-1"9'-7 1/2" FA C E O F S T U D 6'-11" SEE SP1.1 FOR MECHANICAL ENCLOSURE 5.6B 5.6B 5.6B 4.4A 4.4A 6.6G 6.6G 4.4A 4.4A 4.4A 6.6D 6.6D 6.6E 6.6F 6.6E 4.4A 4.4A 6.6D 4.4A 6.6D 6.6C 6.6D 6.6D 6.6C 6.6D 6.6D6.6C6.6D 6.6B 6.6B 6.6B 6.6B 6.6F 6.6F 6.6G 4.4A 6.6D 6.6D 6.6D 4.4A 4.4A 4.4A 4.4A TYP. AT ALL DRIVE-THRU COLUMNS 32 ' - 2 " 1' - 4 " 2'-0 1/2"3'-0 1/2" D.1 C.1 B.1 6'-11"6'-11" 3'-9 1/2"7'-1 21/64" 1. CONTRACTOR SHALL RESOLVE ALL DIMENSIONAL DISCREPANCIES DURING LAYOUT WITH ARCHITECT, PRIOR TO BEGINNING CONSTRUCTION. 2. COORDINATE BLOCKING PRIOR TO WALL FINISHES, INCLUDING OWNER FURNISHED ITEMS. PROVIDE BLOCKING FOR ALL WALL MOUNTED CASEWORK, GRAB BARS, HARDWARE EQUIPMENT, ETC. 3. CAULK ALL INTERIOR JOINTS AND CORNERS. 4. WALL TYPES MAY NOT BE CONSISTENT ACROSS THE FULL LENGTH OR HEIGHT OF EACH WALL. SEE WALL TAGS, ELEVATIONS, AND WALL SECTIONS FOR EACH WALL TO DETERMINE FINAL HORIZONTAL AND VERTICAL SUBSTRATE TRANSITIONS AND WALL FINISHES. 5. VERIFY ALL BANK EQUIPMENT LOCATIONS WITH SUPPLIER. GENERAL NOTES I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 3 : 5 5 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A1.1 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . DI M E N S I O N P L A N MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE: N 1/4" = 1'-0" DIMENSION PLAN BREAK 107 OFFICE 1 104 MECH. 111 JAN./STOR. 112 COIN SORT. MANAGER 103 HALLWAY 108 AA A3.1 AA A3.1 66 4 3 11 2 A A B B DE E 5 DRIVE-THRU 106OFFICE 2 113 DD A3.2 DD A3.2 14 A4.3 14 A4.3 A5.2 3 13 A4.3 13 A4.3 CC A3.1 CC A3.1 EE A3.2 EE A3.2 A5.4 A A5.4 B A5.4 J A5.4 N A5.4 L A5.4 K C A5.4 H ROUGH IN FOR FUTURE UNITS A5.1 1 W1 W1 W1W3 F1B1 W1 W1 W1W3 F1B1 W1 W1 W1W1 F5B2 W1 W1 W1W1 F6B2 W1 W1 W1W1 F6B2 W1 W1 W3W6 F1B1 W1 W1 W1W1 F1B2 A5.4 D BB A3.1 BB A3.1 SP2.2 B AA AA BB BB CC CC 3.5 4.8 1.5 SIM SP2.2 C SIM 112 111 17 A4.4 17 A4.4 W1 W1 W1W1 F3/5B1 104 103 113 OFFICE 3 115 WALL MOUNTED TV PORTABLE CHECK WRITING STAND WAITING AREA I.T. 116 TOILET 117 TOILET 118 TV WALL MOUNTED TV 101B 115 118 117 118118 117 108 101A W2 W2 W2W2 F2B3 W2 W2 W2W2 F2B3 W1 W1 W1W1 F6B2 W1 W1 W1W1 F5 F1B1 W1 W1 W3W6 F1B1 W1 B1 W7 W7 W7 W7 DOOR 101A OPERATOR BUTTONS DOOR 101B OPERATOR BUTTONS 107 MAIN LOBBY 102 A5.1 J H A5.1 2 A5.4 M A5.1 3 A5.2 1 A5.4 G A5.4 C A5.4 E SEE SP1.1 FOR MECHANICAL ENCLOSURE 301302 303 304 305 306 306 303 307 308 307 307 309 310 311312 313 9 A4.2 314 VESTIBULE 101 W3 W3 W7W7 F3 GAS METER LOCATION A5.2 2 W5 F1 106 A4.4 14 A4.4 15 16 A4.4 A5.4 C ROUGH IN FOR FUTURE UNIT TOWER SECURITY CAMERA FUTURE UNIT 1'-3" K SP2.1 SP2.1 G SP2.1 H SP2.1 J 116 D.1 C.1 B.1 F1 F1 NIGHT DEPOSIT BOX LOCATE BETWEEN STUDS VERIFY OPENING WITH OWNERS EQUIPMENT SUPPLIER OVERHEAD PNEUMATIC TUBES BY DIEBOLD DUTCH DOOR FOR OVERFLOW TELLER WALL FINISH W1 TEXTURED/PAINTED GYP. BOARD W2 CERAMIC TILE W3 STOREFRONT SYSTEM W4 (NOT USED) W5 FRP W6 BRICK VENEER W7 3'-0" STONE WAINSCOT WITH STONE SILL AND BRICK VENEER ABOVE FLOOR FINISH F1 CARPET TILE F2 CERAMIC TILE F3 ENTRY CARPET TILE F4 (NOT USED) F5 VINYL COMP. FLOOR TILE F6 CONCRETE - SEALED AND PAINTED BASE FINISH B1 6" MILLED RUBBER BASE B2 4" COVED RUBBER BASE B3 SCHLUTER PROFILE FINISH SCHEDULE KEY SEE FLOOR FINISH ILLUSTRATION ON /1 A1.4 REFER TO ELEVATIONS FOR ADDITIONAL STOREFRONT THAT MAY NOT BE CALLED OUT ON THE MAIN FLOOR PLAN. AA A3.1 4 BE 2 3/4"8 1/2"9'-11 1/2"6 3/4"9'-11 1/2"6 3/4"9'-11 1/2"1'-9 3/4"FA C E O F S T U D 303B 303B 303B A5.4 F A5.4 P A5.4 Q CAMERA AT SOFFIT AT HIGH ROOF I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 3 : 5 9 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A1.2 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . AN N O T A T I O N P L A N MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE: N 1/4" = 1'-0" ANNOTATION PLAN SCALE: 1/4" = 1'-0" A1.2 2 DIMENSION PLAN 66 4 3 11 2 A A B B DE E 5 C MECH. 111 JAN./STOR. 112 HALLWAY 108 BREAK 107 DRIVE-THRU 106 OFFICE 1 104 MANAGER 103 AA AA BB BB CC CC 3.5 4.8 1.5 R A7.2 SEE DETAIL ON /BA1.3 8'-7"C1 8'-7"C1 8'-7"C1 8'-0"C2 8'-0"C2 9'-0"C2 C3 VARY 8'-6"C1 TOILET 118 TOILET 117 I.T. 116 MAIN LOBBY 102 C3 VARY SEE DETAIL /BA1.3 C4 VARY C5 VARY C5 VA R Y C5 V A R Y C5 V A R Y C5 VARY C5 VARY C5 V A R Y C5 VARY C5 V A R Y C5 VARY A1.3 2 1'-6"7'-1 1/2"6"7'-1 1/2"6"7'-1 1/2"6"7'-1 1/2" 1'-6" 1'-6"7'-1 1/2"6"7'-1 1/2"6"7'-1 1/2"6"7'-1 1/2" C4 VARY C4 VARY C3 VARYC3VARYC3VARY C3 VARY C3 VARYC3 VARY C4 VARY 1' - 6 " 2 0 ' - 0 1 / 2 " 1 ' - 6 " 1 ' - 6 " 7 ' - 4 3 / 4 " 1 ' - 6 " A A1.3 A A1.3 9'-0"C2 C4 VARY A A1.3 CAMERA CAMERA FUTURE CAMERA 360 DEGREE CAMERA 360 DEGREE CAMERA SPEAKER AND VOLUME CONTROL CAMERA CAMERA CAMERA CAMERA CAMERAS 360 DEGREE CAMERA FUTURE CAMERA CAMERA CAMERA SPEAKER AND VOLUME CONTROL SPEAKER AND VOLUME CONTROL SPEAKER AND VOLUME CONTROL TWO SPEAKERS - HIGH ON THE WALL ABOVE OFFICES D.1 C.1 B.1 A1.3 1 SEE FOR LOWER CEILING PLAN SEE FOR LOWER CEILING PLAN 24x24 SREVICE ACCESS PANEL TO PNEUMATIC UNIT BLOWERS ABOVE SOFFIT -FIELD VERIFY LOCATION WITH DIEBOLD EQUIPMENT INSTALLERS CURVED WOOD BARREL TRUSS 5/8" GYP BOARD -- ATTACH TO BOTTOM CHORD 7/8" FURRING HAT CHANNEL 16" O.C. 1/2" PLYWOOD 1" 6" SEE STRUCTURAL FOR SPACING 2X4 BLOCKING BETWEEN TRUSSES TO SUPPORT ENDS OF CHANNEL (AS NEEDED). SHADOW JOINT PARALLEL TO TRUSS PERP. TO TRUSS PERP. EDGE DETAIL CURVED WOOD BARREL TRUSS 5/8" GYP BOARD -- ATTACH TO BOTTOM CHORD 7/8" FURRING HAT CHANNEL 16" O.C. 1/2" PLYWOOD 1" SHADOW JOINT 1/2" ZINTRA ACOUSTICAL PANEL FULLY ADHERED, BUTTED JOINTS AS REQ'D TO CONCEAL JOINTS 1" 1/2" ZINTRA ACOUSTICAL PANEL FULLY ADHERED, BUTTED JOINTS AS REQ'D TO CONCEAL JOINTS WALL OR STOREFRONT 1'-6" TO INSIDE FACEOF1" CEILING FINISH C1 2 X 4 LAY-IN ACOUSTICAL PANELS C2 GYPSUM BOARD OVER WOOD STUDS C3 ZINTRA ACOUSTICAL PANEL OVER CURVED PLYWOOD C4 GPYSUM BOARD DIRECT APPLICATION (PAINT) C5 PREFINISHED METAL SOFFIT C6 12 x 12 GLUE-UP ACOUSTICAL TILES CEILING SCHEDULE KEY C R O S S R U N N E R MAIN RUNNER 4 5 ° M A X . 1/2" CONDUIT COMPRESSION BRACE - FULL HEIGHT - TYP. VERTICAL WIRES AT 4'-0" O.C. 4 5 ° M A X . SPLAY WIRE AT 12'-0" O.C. IN EACH PLAN OF EACH RUNNER 2" MIN. SEISMIC CLIP 7/8" X 7/8" WALL MOLDING 3/4" CLEAR AT UNATTACHED END LATERAL FORCED BRACING REQUIRED FOR CEILING AREAS OVER 1,000 S.F. CEILING AREAS UNDER 1,000 S.F. ARE NOT. RIDGED BRACES MAY BE USED INSTEAD OF DIAGONAL SPLAY WIRES. A SEISMIC SEPARATION JOINT IS REQUIRED FOR CEILING AREAS GREATER THAN 2,500 S.F. MAIN OR CROSS RUNNER 8" MAX. 12 GA. WIRE OR APPROVED WALL SUPPORT PERIMETER SPACER AT UNATTACHED WALLS LATERAL FORCE BRACE DETAIL WALL MOLDING DETAIL 1 2 '-0 " T Y P . 6 '-0 " M A X .. 12'-0" TYP. 6'-0" MAX.. SUSPENSION SYSTEM LAYOUT NOT TO SCALE CEILING SUSPENSION SYSTEM FIRST LINE OF BRACING CEILING GRID SHALL BE ATTACHED TO WALL MOLDING AT TWO ADJACENT WALLS LATERAL FORCE BRACE DETAIL WALL MOLDING WALL MOLDING SUSPENDED CEILING TO BE INSTALLED TO MANUFACTURERS SPECIFICATIONS. (SPEC SECTION 09 5123.3.2.A) 4 3 E 5 OFFICE 2 113 OFFICE 3 115 10'-0"C6 10'-0"C6 FUTURE CAMERA FUTURE CAMERA SPEAKER AND VOLUME CONTROL SPEAKER AND VOLUME CONTROL SPEAKER AND VOLUME CONTROL 1'-0" 1' - 1 1 / 4 " PRE-FINISHED METAL SOFFIT 2X WOOD FRAMING FASTENED TO BOTTOM CORD FOR WOOD TRUSS 2X4 WOOD FRAMING 1/2" WOOD SHEATHING PRE-FINISHED METAL FASCIA PRE-FINISHED METAL SOFFIT 66 D C C5 VARY C5 VARY C5 VARY 360 DEGREE CAMERA HEIGHT STRIP CAMERA I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 2 0 / 2 0 2 3 7 : 0 7 : 3 3 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h R e x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e hi v e F C U N o r t h R e x b u r g v _ 2 3 . r v t A1.3 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE F L E C T E D C E I L I N G P L A N MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE: N 1/4" = 1'-0" REFLECTED CEILING PLAN SCALE: 1 1/2" = 1'-0" A1.3 B DETAIL SCALE: 1 1/2" = 1'-0" CEILING GRID BRACING SCALE: 1/4" = 1'-0" A1.3 2 REFLECTED CEILING PLAN SCALE:1" = 1'-0" A1.3 A DETAIL SCALE: 1/4" = 1'-0" A1.3 1 REFLECTED CEILING PLAN 1 City Plan Review 4/21/23 1 CERAMIC TILES FLOOR FINISH KEY OFFICE MANAGER DRIVE-THRU BREAK UNI-SEX UNI-SEX JANITORIAL OFFICE OFFICE MECHANICAL A A1.4 A A1.4 B A1.4 C A1.4 C A1.4 G A1.4 G A1.4 E A1.4 E A1.4 G A1.4 TYP. G A1.4 TYP. E A1.4 E A1.4 G A1.4 D A1.4 D A1.4 H A1.4 H A1.4 H A1.4 WI T H F U L L T I L E 4' - 0 " M I N . - E N D LUXURY VINYL PLANKS ENTRY CARPET TILES CARPET TILES HERRINGBONE LVP PAINTED CONCRETE A A1.4 J A1.4 G A1.4 G A1.4 G A1.4 F A1.4 G A1.4 J A1.4 J A1.4 G A1.4 4' - 0 " 3" T O 8 " 4" 6" OR 7" 3/ 4 " 6" TO 7" 3" ROOM A 6" 8" ROOM3/ 4 " B 3 1 / 2 " BRAILLE BRAILLE LUXURY VINYL PLANK CONCRETE SLAB ON GRADE SCHLUTER VINPRO-S FLOOR EDGE CARPET TILE CARPET TILES CONCRETE SLAB ON GRADE SCHLUTER VINPRO-U FLOOR EDGE CARPET TILES CONCRETE SLAB ON GRADE SCHLUTER VINPRO-S FLOOR EDGE STONE THRESHOLD TILE OVER THIN SET LUXURY VINYL PLANK CONCRETE SLAB ON GRADE 1/ 2 " - M I N . 2X WOOD FRAMING WITH DRYWALL 4" COVED RUBBER BASE CARPET TILES (BOTH SIDES) CONCRETE SLAB ON GRADE ALUMINUM STOREFRONT SYSTEM SCHLUTER VINPRO-S FLOOR EDGE (NO BASE) 6 1 / 2 " LUXURY VINYL PLANK CONCRETE SLAB ON GRADE 2X WOOD FRAMING 4 1/2" COVED STAINLESS STEEL BASE 3/4" FINISH PANEL CARPET TILES CONCRETE SLAB ON GRADE 1/ 2 " - M I N . 2X WOOD FRAMING WITH DRYWALL 4" COVED RUBBER BASE PAINTED CARPET TILES CONCRETE SLAB ON GRADE 1/ 2 " - M I N . 2X WOOD FRAMING WITH DRYWALL 4" COVED RUBBER BASE CARPET TILES CONCRETE SLAB ON GRADE 1/ 2 " - M I N . 2X WOOD FRAMING WITH DRYWALL 6" MILLED RUBBER BASE FLOOR & BASE FINISH SCHEDULE CARPET TILE: J&J INVISION TWILL WEAVE 2879 PERCALE 24x24 (CARPET TO BE PLACED MONOLITHICALLY PATTERENED) ENTRANCE MATTING: MOHAWK FIRST STEP II 859 WALNUT 24x24 LUXURY VINYL PLANK: KARNDEAN KOROK SELECT LOBBY - HERRINGBONE SM-RKP8209 SALVAGED BARNWOOD BREAKROOM - PLANK RKP8209 SALVAGED BARNWOOD FLOOR TILE: DAL TILE MUSEO ARTISTIC GREY MU31 GROUT: LATICRETE NATURAL GRAY 24 CONCRETE SLAB: SHERWIN WILLIAMS "PRIMER GREY" BASE: TARKETT 6" MILLED MW-XX-F6 REVEAL, 167 FUDGE 4" COVED 167 FUDGE STAINLESS STEEL 4" COVED I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 4 : 0 9 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A1.4 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . SI G N A G E , F L O O R F I N I S H E D , A N D D E T A I L S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE: 1/4" = 1'-0" A1.4 1 ANNOTATION PLAN SIGNAGE SCHEDULE SIGN MESSAGE ROOM # ROOM LOCATION SIZE AND TYPE COMMENTS BREAK 107 BREAK 6" X 3" TYPE A DRIVE-THRU 106 DRIVE-THRU 6" X 3" TYPE A JANITORIAL 112 JAN./STOR. 6" X 3" TYPE A MANAGER 103 MANAGER 6" X 3" TYPE A MECHANICAL 111 MECH. 6" X 3" TYPE A OFFICE 104 OFFICE 1 6" X 3" TYPE A OFFICE 113 OFFICE 2 6" X 3" TYPE A OFFICE 115 OFFICE 3 6" X 3" TYPE A UNI-SEX 117 TOILET 6" X 8" TYPE B UNI-SEX 118 TOILET 6" X 8" TYPE B SCALE: 1/4" = 1'-0" A1.4 2 SIGN LOCATION SCALE: 3" = 1'-0" A1.4 3 SIGN TYPE SCALE: 3" = 1'-0" A1.4 A SECTION SCALE: 3" = 1'-0" A1.4 B SECTION SCALE: 3" = 1'-0" A1.4 C SECTION SCALE: 3" = 1'-0" A1.4 D SECTION SCALE: 3" = 1'-0" A1.4 E SECTION TEXT SCALE: 3" = 1'-0" A1.4 F SECTION SCALE: 3" = 1'-0" A1.4 J SECTION SCALE: 3" = 1'-0" A1.4 H SECTION SCALE: 3" = 1'-0" A1.4 G SECTION BREAK 107 OFFICE 1 104 MECH. 111 JAN./STOR. 112 MANAGER 103 HALLWAY 108 DRIVE-THRU 106 OFFICE 2 113 OFFICE 3 115 I.T. 116 TOILET 117 TOILET 118 MAIN LOBBY 102 FA C E O F S T U D SEE SD1.1 FOR MECHANICAL ENCLOSURE TYP. AT ALL DRIVE-THRU COLUMNS COIN OP DUTCH DOOR - STOREFRONT OR WOOD - OVERFLOW TELLER ATM CCTV TELLER CCTV TELLER CCTV TELLER (FUTURECCTV TELLER (FUTURE FUTURE FURNITURE FURNITURE COPIER DRIVE-THRU WINDOW & DRAWER PNEUMATIC TUBES CASH RECYCLER SAFE 3'-0 1/2"2'-0 1/2" NIGHT DEPOSIT REFRIGERATOR MICROWAVE CASH RECYCLER SOUND SYSTEM SECURITY SYSTEM FURNITURE FURNITURE FURNITURE FURNITURE OCCUPIED/VACANT LANE LIGHTING (CANOPY ABOVE) VESTIBULE 101 2' - 0 1 / 4 " 3'-3" FUTURE PNEUMATIC TUBES I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 4 : 1 1 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A1.5 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . OW N E R F U R N I S H E D P L A N MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE: N 1/4" = 1'-0" OWNER FURNISHED PLAN GENERAL NOTE: SOAP, TISSUE PAPER AND PAPER TOWEL DISPENSERS ARE OWNER PROVIDED (NOT IN CONTRACT) MAIN F.P. 100'-0" 643125 T.O. SILL 103'-0" T.O. FOOTING 97'-0" 301 300 723 719 719 720 412 414 406 721 720 721 720 721 719 723 503 301 300 412 406 414 721 720 1123 27'-9 1/2" 1 8 '-0 " 1 " / 1 '-0 " 27'-2 1/2" P A5.4 305 MAIN F.P. 100'-0" ABDE T.O. SILL 103'-0" T.O. FOOTING 97'-0" C B.O. SOFFIT 109'-2" AABBCC 412 406 719 719 720 720 721 721 721 721 406 1120 523 721 503 503 301 300 17'-0" 523523 720 721 414 503 720 503 720 720 721 716 4' - 0 " 1' - 6 3 / 4 " 1 ' - 6 " 303A 303 301302304 306 1028 723 723 523 CONNECT DOWNSPOUT TO UNDERGROUND DRAINAGE SYSTEM SEE DETAIL J/SP2.3 AND CIVIL SHEET C6.00. SNOW RAILS - SEE SPECS MAIN F.P. 100'-0" A B E T.O. SILL 103'-0" T.O. FOOTING 97'-0" B.O. SOFFIT 109'-2" AA BB CC 1120 523 721 721 406 720 721 716 720 716 414 412 720 503 716 721 719 1123 301 300 412 414 406 503 723 720 719 720 720 720 721 721 716 303B303B303B SEE /2 A1.2 F A5.4 P A5.4 314 306 D.1 CONNECT DOWNSPOUT TO UNDERGROUND DRAINAGE SYSTEM SEE DETAIL J/SP2.3 AND CIVIL SHEET C6.00. SNOW RAILS - SEE SPECS MAIN F.P. 100'-0" 6 4 12 T.O. SILL 103'-0" T.O. FOOTING 97'-0" 3.54.8 1.5 301 300 412 414 406 721 720 719 723 719 720 721 523 1120 PROVIDE ROUGH-IN FOR FUTURE UNIT 721 721 721 2 7 '-9 1 /2 " 19'-5 35/64" 2 5 '-7 5 1 /6 4 " 1" / 1'-0" 300 412 721 719 720 F A5.4 307 307 307308 523 723 723 I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 4 : 1 7 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A2.1 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . BU I L D I N G E L E V A T I O N S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE: 3/16" = 1'-0"A2.1 3 WEST ELEVATION SCALE: 3/16" = 1'-0"A2.1 1 SOUTH ELEVATION SCALE: 3/16" = 1'-0"A2.1 2 NORTH ELEVATION SCALE: 3/16" = 1'-0"A2.1 4 EAST ELEVATION KEYNOTE LEGEND NO. KEYNOTE 300 REINFORCED CONCRETE FOOTING - SEE STRUCTURAL 301 REINFORCED CONCRETE FOUNDATION WALL - SEE STRUCTURAL 406 BRICK VENEER 412 4" MANUFACTURED STONE VENEER 414 MANUFACTURED STONE SILL 503 STEEL TUBE - PAINTED WHERE EXPOSED - SEE STRUCTURAL 523 STEEL PIPE BOLLARD FILLED WITH CONCRETE 716 PRE-FINISHED METAL SOFFIT 719 PRE-FINISHED METAL GUTTER 720 STANDING SEAM METAL ROOF 721 PRE-FINISHED METAL FASCIA 723 DOWNSPOUT 1028 DOOR OPERATOR BUTTON 1120 ATM UNIT 1123 SIGNAGE BY OWNER - COORDINATE WITH CONTRACTOR GENERAL NOTES: 1. ALL NON-PRE-FINISHED FOOR PENETRATIONS AND VENTS SHALL BE PAINTED TO MATCH ROOF COLOR. 2. CMU/BRICK SEALER TO BE APPLIED ALL LOCATIONS. 3. APPLY DAMPPROOFING TO BUILDING FOUNDATION WALLS. MAIN F.P. 100'-0" 6 4 3 25 DD A3.2 T.O. SILL 103'-0" T.O. FOOTING 97'-0" A4.1 1 A4.1 5 A4.1 2 A4.1 3 EE A3.2 MAIN LOBBY 102 JAN./STOR. 112 MECH. 111 9 A4.2 T.O. TOP CHORD R 55'-0" 1" / 1'-0" T . O . T O P C H O R D R 5 5 ' - 0 " 2 7 '-9 5 /8 " 17'-5" MAIN F.P. 100'-0" 6 4 3 125 DD A3.2 T.O. SILL 103'-0" T.O. FOOTING 97'-0" EE A3.2 A4.2 7 A4.1 4 A4.2 10 2 5 '-7 6 5 /1 2 8 " 2 7 '-9 1 /2 " MANAGER 103 OFFICE 1 104 DRIVE-THRU 106 BREAK 107 T.O. TOP CHORD R 55'-0"T . O . T O P C H O R D R 5 5 ' - 0 " 19'-5 1/4" 1" / 1'-0" MAIN F.P. 100'-0" T.O. SILL 103'-0" T.O. FOOTING 97'-0" B.O. SOFFIT 109'-2" 3.54.8 1.5 A7.2 H A7.2 H 9 A4.2 1/2" / 1'-0"1/2" / 1'-0" I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 4 : 2 0 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A3.1 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . BU I L D I N G S E C T I O N S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE: 1/4" = 1'-0" A3.1 AA BUILDING SECTION SCALE: 1/4" = 1'-0" A3.1 CC BUILDING SECTION SCALE: 1/4" = 1'-0" A3.1 BB BUILDING SECTION MAIN F.P. 100'-0" AA A3.1 ABE T.O. SILL 103'-0" T.O. FOOTING 97'-0" CC A3.1 B.O. SOFFIT 109'-2" 9' - 8 " BB A3.1 AABBCC A7.2 J A4.3 11 A4.2 8 A4.3 12 17 A4.4 MAIN LOBBY 102 OFFICE 3 115 OFFICE 1 104 T.O. CONCRETE - 99'-6" A1.3 A A1.3 A 6' - 1 0 " LIGHTS CENTERED OVER PATRON OPENINGS IN CASEWORK MAIN F.P. 100'-0" AA A3.1 A B D E T.O. SILL 103'-0" T.O. FOOTING 97'-0" CC A3.1 C B.O. SOFFIT 109'-2" BB A3.1 AA BB CC A4.2 6 17 A4.4 DRIVE-THRU 106 OFFICE 2 113 MAIN LOBBY 102 A1.3 A A1.3 A A7.2 H I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 4 : 2 3 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A3.2 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . BU I L D I N G S E C T I O N S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE: 1/4" = 1'-0" A3.2 DD BUILDING SECTION SCALE: 1/4" = 1'-0" A3.2 EE BUILDING SECTION I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 1 7 : 5 2 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A3.3 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . 3D S E C T I O N S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE: 3D SECTIONS SCALE: 3D SECTIONS SCALE: 3D SECTIONS MAIN F.P. 100'-0" 6 T.O. SILL 103'-0" T.O. FOOTING 97'-0" 6.6D 300 414 624 412 503 A7.2 E R01 603 705 303 906 906 MAIN LOBBY 102 716 719 720 603 615 709 A6.2 S 503 309 604 601 807 632 EXT. EXT. A1.4 D 709 300 503 ? 701 MAIN F.P. 100'-0" T.O. SILL 103'-0" T.O. FOOTING 97'-0" 412 414 6.6D 6.6C A7.2 D 300 303 626 720 MECH. 111 705 301 406 603 906 603 719 721 716 632 601 710 906 3203 309 EXT. EXT. A1.4 D R04 701 MAIN F.P. 100'-0" 2 T.O. FOOTING 97'-0" R01 A7.2 C 9'-0"C2 R02 6.6B JAN./STOR. 112 MECH. 111 303 709 709 906 720 716 603 720 721 906 709 632 800 309 603 906 626 603 615 906 303 MAIN F.P. 100'-0" 4 601 503 A7.2 B A7.2 A MAIN LOBBY 102 709 906 721 716 720 603R01 R01 906 906 709 603 720 906 622 622 906 622 624 603 303 632 309 Y A6.2 Y A6.2 9 A4.2 9 A4.2 615 615 502 503 MAIN F.P. 100'-0" 6 T.O. SILL 103'-0" T.O. FOOTING 97'-0" 6.6D MANAGER 103 A6.2 S 300 705 303 412 414 801 906 709 603 8'-7"C1 R01 720 603 721 719 632 601 709 503 309 604 601 716 A1.4 D 615 807 EXT. EXT. A7.2 E SIM 503 701 I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 2 0 / 2 0 2 3 7 : 0 6 : 3 6 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h R e x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e hi v e F C U N o r t h R e x b u r g v _ 2 3 . r v t A4.1 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . WA L L S E C T I O N MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE:3/4" = 1'-0" A4.1 1 WALL SECTION SCALE: 3/4" = 1'-0" A4.1 5 WALL SECTION SCALE: 3/4" = 1'-0" A4.1 3 WALL SECTION SCALE: 3/4" = 1'-0" A4.1 2 WALL SECTION KEYNOTE LEGEND NO. KEYNOTE 300 REINFORCED CONCRETE FOOTING - SEE STRUCTURAL 301 REINFORCED CONCRETE FOUNDATION WALL - SEE STRUCTURAL 303 REINFORCED CONCRETE SLAB - SEE STRUCTURAL 309 4" AGGREGATE BASE 406 BRICK VENEER 412 4" MANUFACTURED STONE VENEER 414 MANUFACTURED STONE SILL 502 STEEL BEAM - PAINTED WHERE EXPOSED- SEE STRUCTURAL 503 STEEL TUBE - PAINTED WHERE EXPOSED - SEE STRUCTURAL 601 2X WOOD FRAMING 603 WOOD SHEATHING 604 SOLID SURFACE SILL 615 BARREL TRUSS - SEE STRUCTURAL 622 FINISHED WOOD TRIM 624 2X6 FRAMING 626 9 1/2" TJI 632 LSL RIM BOARD 701 BITUMINOUS DAMPPROOFING TYP. 705 2" RIGID INSULATION CONTINUOUS AT FOUNDATION WALL. 709 BATT INSULATION FULL THICKNESS 710 R-13 MIN, SPRAYED ON THERMAL INSULATION SYSTEM 716 PRE-FINISHED METAL SOFFIT 719 PRE-FINISHED METAL GUTTER 720 STANDING SEAM METAL ROOF 721 PRE-FINISHED METAL FASCIA 800 DOOR & FRAME 801 ALUMINUM WINDOW SYSTEM 807 ROLL SUN SHADE 906 5/8" GYPSUM BOARD 3203 4" THICK CONCRETE SIDEWALK U.N.0. WITH SAWCUT CONTROL JOINTS SEE DETAIL SCALE: 3/4" = 1'-0" A4.1 4 WALL SECTION 1 City Plan Review 4/21/23 1 1 1 MAIN F.P. 100'-0" 4 A7.2 F 6.6B R01 R01 601 720 720 615 631 615 8'-7"C1 8'-7"C1 300 906 OFFICE 1 104 DRIVE-THRU 106 303 603 906 709 716 632 721 309 MAIN F.P. 100'-0" 1 T.O. FOOTING 97'-0" 626 6.6D 705 300 301 303 412 8'-6"C1 716 721 632 719 720 710 601 603 709 906 EXT. EXT. A7.2 D SIM R04 906 701 MAIN F.P. 100'-0" A T.O. FOOTING 97'-0" 6.6B 303 R01 8'-7"C1 705 300 412 414 406 709 406 720 DRIVE-THRU 106 A6.2 U A7.2 G EXT. EXT. 301 309 1'-0" 6" 906 603 6.6D A6.2 C 3200 3201 624 633 624 601 603 601 601632 721 716 507 507 807 OP E N E L E C T R I C A L C H A S E OWNER FURNISHED WINDOW 716 701 MAIN F.P. 100'-0" A T.O. SILL 103'-0" T.O. FOOTING 97'-0" A7.2 G R01 303 6.6C 8'-7"C1 OFFICE 1 104 412 414 705 709 801 406 709 709 601 716 603 A6.2 S EXT. EXT. 3200 3201 309 603 906 507 633 603 624 507 721 720 601 807 A7.2 L SIM 301 300 604 906 12" 701 MAIN F.P. 100'-0" 10'-0"C6 MAIN LOBBY 102 OFFICE 3 115 801 303 622 906 A6.2 Y 633 309 111'-8" - T.O. WALL I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 2 0 / 2 0 2 3 7 : 0 5 : 1 0 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h R e x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e hi v e F C U N o r t h R e x b u r g v _ 2 3 . r v t A4.2 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . WA L L S E C T I O N S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE:3/4" = 1'-0" A4.2 7 WALL SECTION SCALE: 3/4" = 1'-0" A4.2 10 WALL SECTION SCALE: 3/4" = 1'-0" A4.2 6 WALL SECTION KEYNOTE LEGEND NO. KEYNOTE 300 REINFORCED CONCRETE FOOTING - SEE STRUCTURAL 301 REINFORCED CONCRETE FOUNDATION WALL - SEE STRUCTURAL 303 REINFORCED CONCRETE SLAB - SEE STRUCTURAL 309 4" AGGREGATE BASE 406 BRICK VENEER 412 4" MANUFACTURED STONE VENEER 414 MANUFACTURED STONE SILL 507 STEEL ANGLE - PAINTED WHERE EXPOSED - SEE STRUCTURAL 601 2X WOOD FRAMING 603 WOOD SHEATHING 604 SOLID SURFACE SILL 615 BARREL TRUSS - SEE STRUCTURAL 622 FINISHED WOOD TRIM 624 2X6 FRAMING 626 9 1/2" TJI 631 WOOD BEAM - SEE STRUCTURAL 632 LSL RIM BOARD 633 WOOD HEADER - SEE STRUCTURAL 701 BITUMINOUS DAMPPROOFING TYP. 705 2" RIGID INSULATION CONTINUOUS AT FOUNDATION WALL. 709 BATT INSULATION FULL THICKNESS 710 R-13 MIN, SPRAYED ON THERMAL INSULATION SYSTEM 716 PRE-FINISHED METAL SOFFIT 719 PRE-FINISHED METAL GUTTER 720 STANDING SEAM METAL ROOF 721 PRE-FINISHED METAL FASCIA 801 ALUMINUM WINDOW SYSTEM 807 ROLL SUN SHADE 906 5/8" GYPSUM BOARD 3200 CONCRETE CURB AND GUTTER WITH AGGREGATE BASE 3201 CONCRETE DRIVEWAY WITH AGGREGATE BASE SCALE: 3/4" = 1'-0" A4.2 8 WALL SECTION SCALE: 3/4" = 1'-0" A4.2 9 WALL SECTION 1 City Plan Review 4/21/23 1 1 1 E T.O. FOOTING 97'-0" A7.2 L A7.2 N A7.2 M 17 A4.4 OFFICE 3 115 10'-0"C6 6.6F 6.6G R01 R01 303 406 709 406 716 601 721 720 906 601 906 906 601 801 720 709 603 615 EXT. EXT. 705 301 309 603 412 414 502 603 720 716 701 MAIN F.P. 100'-0" B A7.2 K A7.2 S 8'-7"C1 6.6B 6.6C OFFICE 1 104 MAIN LOBBY 102 303 801 906 906 603 615 720 720 906 709 603 309 624 709 906 721 631 631 615 716 MAIN F.P. 100'-0" 6 T.O. FOOTING 97'-0" 13 A4.3A7.2 Q 8'-4 1/2" R02 R01A7.2 E VESTIBULE 101 EXT. EXT. MAIN LOBBY 102 309 303 800 801 800 801 721 716 603 A7.2 Q 720 603 721 716 709 709 716 721 632 719 615 603 720 SEE D/SP2.1 FOR FROST WALL DETAIL A6.2 X 300 705 301 503 503 503503 906 701 MAIN F.P. 100'-0" D T.O. SILL 103'-0" T.O. FOOTING 97'-0" C A7.2 T R 2 0 ' - 0 " 16'-9 1/2" VESTIBULE 101 R02 412 412 414 414 406 406 632 303 412 412 414 414 406 406 632 721 720 716716 721 720 309 701 701 I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 2 0 / 2 0 2 3 7 : 0 3 : 4 0 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h R e x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e hi v e F C U N o r t h R e x b u r g v _ 2 3 . r v t A4.3 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . WA L L S E C T I O N S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE:3/4" = 1'-0" A4.3 11 WALL SECTION SCALE: 3/4" = 1'-0" A4.3 12 WALL SECTION KEYNOTE LEGEND NO. KEYNOTE 300 REINFORCED CONCRETE FOOTING - SEE STRUCTURAL 301 REINFORCED CONCRETE FOUNDATION WALL - SEE STRUCTURAL 303 REINFORCED CONCRETE SLAB - SEE STRUCTURAL 309 4" AGGREGATE BASE 406 BRICK VENEER 412 4" MANUFACTURED STONE VENEER 414 MANUFACTURED STONE SILL 502 STEEL BEAM - PAINTED WHERE EXPOSED- SEE STRUCTURAL 503 STEEL TUBE - PAINTED WHERE EXPOSED - SEE STRUCTURAL 601 2X WOOD FRAMING 603 WOOD SHEATHING 615 BARREL TRUSS - SEE STRUCTURAL 624 2X6 FRAMING 631 WOOD BEAM - SEE STRUCTURAL 632 LSL RIM BOARD 701 BITUMINOUS DAMPPROOFING TYP. 705 2" RIGID INSULATION CONTINUOUS AT FOUNDATION WALL. 709 BATT INSULATION FULL THICKNESS 716 PRE-FINISHED METAL SOFFIT 719 PRE-FINISHED METAL GUTTER 720 STANDING SEAM METAL ROOF 721 PRE-FINISHED METAL FASCIA 800 DOOR & FRAME 801 ALUMINUM WINDOW SYSTEM 906 5/8" GYPSUM BOARD SCALE: 1/2" = 1'-0" A4.3 14 WALL SECTION SCALE: 1/2" = 1'-0" A4.3 13 WALL SECTION 1 City Plan Review 4/21/23 1 1 1 1 MAIN F.P. 100'-0" 4 35 T.O. SILL 103'-0" T.O. FOOTING 97'-0" 6.6B 6.6D6.6D 10'-0"C6 10'-0"C6 R01 A6.2 S A6.2 S A7.2 P 301 309 412 414 801 716 721 632 720 716 721 632 720 A7.2 P Sim OFFICE 3 115 EXT. EXT. EXT. EXT. OFFICE 2 113 303 604 624 709 8' - 2 " 705 303 705 309 301 412 414 603 709 906 624 604 503 807807 300300300 624 624 701 701 LOUVERS - TYP. SECURITY CAMERA - TYP. LIGHT SWITCHES AND THERMOSTAT 1'-9"12'-8 1/4" 10 ' - 2 " PRINTER - N.I.C. SMALL CASEWORK ON BACK WALL 7'-11 1/2" V E R I F Y W I T H M A N U F A C T U R E R HE I G H T M A Y V A R Y MAIN F.P. 100'-0" 6.4A HE I G H T M A Y V A R Y - V E R I F Y W I T H M A N U F A C T U R E R I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 2 0 / 2 0 2 3 6 : 5 8 : 1 7 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h R e x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e hi v e F C U N o r t h R e x b u r g v _ 2 3 . r v t A4.4 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . EN L A R G E D S E C T I O N S A N D E L E V A T I O N MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN KEYNOTE LEGEND NO. KEYNOTE 300 REINFORCED CONCRETE FOOTING - SEE STRUCTURAL 301 REINFORCED CONCRETE FOUNDATION WALL - SEE STRUCTURAL 303 REINFORCED CONCRETE SLAB - SEE STRUCTURAL 309 4" AGGREGATE BASE 412 4" MANUFACTURED STONE VENEER 414 MANUFACTURED STONE SILL 503 STEEL TUBE - PAINTED WHERE EXPOSED - SEE STRUCTURAL 603 WOOD SHEATHING 604 SOLID SURFACE SILL 624 2X6 FRAMING 632 LSL RIM BOARD 701 BITUMINOUS DAMPPROOFING TYP. 705 2" RIGID INSULATION CONTINUOUS AT FOUNDATION WALL. 709 BATT INSULATION FULL THICKNESS 716 PRE-FINISHED METAL SOFFIT 720 STANDING SEAM METAL ROOF 721 PRE-FINISHED METAL FASCIA 801 ALUMINUM WINDOW SYSTEM 807 ROLL SUN SHADE 906 5/8" GYPSUM BOARD SCALE:1/2" = 1'-0" A4.4 17 SECTION SCALE: 1/4" = 1'-0"A4.4 14 ELEVATION SCALE: 1/4" = 1'-0"A4.4 15 ELEVATION SCALE: 3/4" = 1'-0" A4.4 16 SECTION 1 City Plan Review 4/21/23 11 2' - 0 " 6 " 3 ' - 0 " 6 " 2 ' - 0 " 11 12 P A5.1 N A5.1 N A5.1 A WT-1 AT-1 5' - 6 " 6 " 2 ' - 0 " P A5.1 N A5.1 N A5.1 11 12 F E GB D A C WT-1 AT-1 P A5.1 N A5.1 2' - 0 " 6 " 3 ' - 0 " 6 " 2 ' - 0 " N A5.1 11 12 E F G K A5.1 WT-1 AT-1 12 AT-1 2' - 0 " 6 " 3 ' - 0 " 6 " 2 ' - 0 " P A5.1 N A5.1 N A5.1 11 12 21 L A5.1 L A5.1 K A5.1 WT-1 AT-1 12 AT-1 4" 3 ' - 4 " 55" K A5.2 1'-6" 6 5 14 9 3 UNDERCOUNTER CPU BRACKET PL-2 PL-2 PL-1 14 19 23 M A5.2 20 9 5 6 3 25 5 6 3 8 30" 19" 3" END PANEL TOWER SECURITY CAMERA R A5.2 PL-1 PL-2 PL-2 PL-2 PL-2 14 19 24 23 9 PL-1 S A5.2 18"28" L A5.2 K A5.2 UNDERCOUNTER CPU BRACKET 14 5 6 3 3 3 1 PL-1 PL-2 PL-2 24 A5.1 A B C D 1'-4" 2' - 5 1 / 4 " 5 ' - 2 " 3 ' - 6 " 5 ' - 2 " 2 ' - 8 1 / 2 " 1'-4" A5.1 C B A D A5.1F E 1' - 2 1 / 2 " 1 ' - 1 " 1 ' - 2 1 / 2 " 2' - 0 " 2' - 0 " A5.1 E 1'-4"6'-8" 40 " 28" 30" 30" L A5.2 22 5 6 333 9 F/E PL-2 PL-2 PL-1 5' - 0 " M A5.1 L A5.1 N A5.1 L A5.1 1'-2" 11 WT-1 5' - 0 " 3'-1 1/4" M A5.1 N A5.1 3' - 0 " EQ EQ 11 J L L A5.1 H H WT-1 WALL-HUNG LAVATORY (PIPES WRAPPED) MIRROR* PAPER TOWEL DISPENSER* SOAP DISPENSER* WATER CLOSET TOILET PAPER AND/OR SANITARY NAPKIN DISPENSER GRAB BARS SIGNAGE DRINKING FOUNTAIN SINGLE BASIN SINK SEMI-RECESSED F.E. CABINET MOP SINK AND FAUCET MOP RACK FIXTURE & ACCESSORIES KEY **SEE ANSI MOUNTING HEIGHTS FOR FIXTURE AND ACCESSORIES ON SHEET G2.0** A B C D E F G H J K L M N *OWNER FURNISHED, CONTRACTOR INSTALLED 1. ALL DISPENSERS ARE OWNER FURNISHED - CONTRACTOR INSTALLED. 2. CABINET FINISH AND COUNTER TOPS SHALL BE PLASTIC LAMINATE - U.N.O.. SEE SCHEDULE BELOW. 3. PROVIDE SCHLUTER TILE TRIM AROUND ALL EXPOSED TILE EDGES, INTERIOR AND EXTERIOR TILED CORNERS, AND TILED WALL TO FLOOR CONDITIONS. 4. CONTRACTOR SHALL PROVIDE ACCESSORY TRIM PIECES FOR SCHLUTER TRIM. 5. GROMMET HOLE LOCATIONS, IN COUNTERTOPS, TO BE FIELD VERIFIED WITH OWNER PRIOR TO DRILLING. GENERAL NOTES INTERIOR KEYNOTES CABINET FILLER - ON UPPER CABINETS PROVIDE BOTTOM AND TOP FOR FILLER 12" DEEP UPPER CABINET 24" DEEP BASE CABINET 24" DEEP MICROWAVE CABINET PLASTIC LAMINATE COUNTERTOP PLASTIC LAMINATE BACKSPLASH QUARTZ COUNTERTOP (QZ-1) 20" DEEP CABINET (ELEC. CHASE BEHIND) BASE - SEE FINISH TAG SHEET A1.4 BASE - SEE CASEWORK SECTIONS 12" x 24" WALL TILE (WT-1) 2" x 2" MATT ACCENT TILE - 2 BANDS (AT-1) APPLIANCES - N.I.C. OFFICE EQUIPMENT - N.I.C. GROMMET - VERIFY LOCATION WITH OWNER GATE WITH BOMMER 3029-5 HINGES, SEE E/A5.3 3/4" PLASTIC LAMINATE ACCENT PANEL (PL-2) FRP (FP-1) WINDOW SYSTEM PAINTED METAL COUNTER TOP BRACKET DOOR AND HOLLOW METAL FRAME STOREFRONT SYSTEM PNEUMATIC TUBE SYSTEM BY OWNER - VERIFY ROUGH IN RECOMMENDATIONS FUTURE PNEUMATIC TUBE SYSTEM BY OWNER - VERIFY ROUGH IN RECOMMENDATIONS REMOVABLE 3/4" PANEL(S), MOUNT WITH Z-CLIPS ON 2x HORIZ. FRAMING SIM TO DETAIL M/A5.2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 SCHLUTER DILEX-EHK COVED PROFILE WALL TILE AND THIN SET BACKER BOARD FOR TILE TILE ON THIN SET ON CONCRETE SLAB SCHLUTER DILEX-EHK COVED PROFILE WALL TILE AND THIN SET BACKER BOARD FOR TILE WALL TILE AND THIN SET SCHLUTER DILEX-AHKA COVED PROFILE WALL TILE AND THIN SET BACKER BOARD FOR TILE RESILIENT FLOOR ON CONCRETE SLAB SCHLUTER SCHIENE PROFILE WALL TILE AND THIN SET BACKER BOARD FOR TILE H.M. FRAME WHERE OCCURS A5.1 Q A5.1R A5.1 S T U A5.1 W V X A5.1 R G A5.3 8" 0 " 9 6 1 / 2 " 2 1 / 2 " 10 7 " 25" 3 1/2" 23" 3 1/2" 27 1/2" 3 1/2" 23" 3 1/2" 27 1/2" 3 1/2" 23" 3 1/2" 25" 195" 20 " 32" 4 1/2" 186" 4 1/2" 15"97"22"39"15" 61 1 / 2 " 3' - 4 " 61 1 / 2 " 14 5" 3 ' - 7 " 3'-0" 18 N M 9 FP-1 A5.1 BB Y AA Z 90 1 / 2 " 2 5 " 74 3 / 8 " 1 0 " 2 5 " 16 5/8"15 1/8"23 3/8" 25"10"20" *40"30 1/2"25" 12'-6 1/2" 11 5 1 / 2 " 9' - 1 3 / 8 " 15 1 / 8 " 2 5 " 55" 3' - 4 1 / 8 " 9' - 1 3 / 8 " A6.2 R A6.2 R 58 7 / 8 " 1' - 6 3 / 8 " (PL-1) 19 14 *VERIFY ROUGH-IN DIMENSIONS WITH OWNER PRIOR TO MILLWORK CONSTRUCTION 25 ROUNDED CORNER A A5.3 B A5.3 17 7 10 R 39'-8" R 476" R 39'-8"R 39'-8" 4' - 1 0 " 5" 2'-0 1/2" 2 1/2" 2'-0" 2 1/2" 2'-4 1/2" 2 1/2" 2'-0" 2 1/2" 2'-4 1/2" 2 1/2" 2'-0" 2 1/2" 2'-0 1/2" 4 1 / 2 " 46 3 / 8 " 5 3 / 4 " 8 1 / 8 " 1' - 0 3 / 8 " 1' - 6 3 / 8 " 2' - 2 1 / 4 " 3' - 0 1 / 4 " QZ-1 PL-2 PL-1PL-4 PL-4 1010 7 C A5.3 E A5.3 17 4' - 1 0 " 5' - 6 " 5'-6 1/2" 3'-0" 2 1/2" 1' - 6 " R 4'-5" 2 7 / 8 " QZ-1 PL-2 7 QZ-1 PL-1 PL-1 PL-4 PL-2 G A5.3 7 10 11" 3' - 4 " 5' - 6 " 1'-7" C A5.3 PL-4 PL-1 A A5.3 B A5.3 14 10 7 2'-3" 2'-0" 2'-9 1/2" 2'-0" 2'-9 1/2" 2'-0" 2'-3" 193" 1'-8"1'-8" 1'-8" 1'-6" 1'-8" 1'-7" 1'-10" 3' - 4 " 4' - 1 0 " 21" PL-1 (TYP.) 7 PL-1 (TYP.) PL-4 (TYP.)7 7 16164' - 4 " C A5.3 E A5.3 10 7 8" 1 ' - 6 " 3 ' - 4 " 5' - 6 " 11" 5'-1 1/2" 3'-0" 2 1/2" 1'-9" 3'-3" 1 16 7 PL-4 QZ-1 QZ-1 PL-1 PL-1 PL-1 14 77 10 2' - 1 0 " 4'-11 3/4"2'-6"8'-9 1/4" PL-116PL-1 QZ-1 7 16 PL-2 QZ-1 C A5.3 E A5.3 7 10 7 39" 21" 1 2 1/2" 36" 61 1/2" 11" 8" 1 8 " 4 0 " 66 " QZ-1 QZ-1 PL-4 16PL-1 PL-1 PL-1 G A5.3 8" 1 ' - 6 " 3 ' - 4 " 5' - 6 " 11"1'-7" 10 7 10 2'-10" PL-1 PL-4 SCHLUTER RONDEC PROFILE WALL TILE AND THIN SET BACKER BOARD FOR TILE3'-0" 4' - 0 " 18 M 9 21 H MILLWORK FINISH SCHEDULE P-LAM: WILSON ART, #7949K-18 "ASIAN NIGHT" P-LAM: PIONITE, #AT440, "CONNECTED CUBES" P-LAM: PIONITE, BLACK SE101 SUEDE P-LAM: FORMICA, "BRUSHED ARGENT M5311" QUARTZ: CAMBRIA, "IRONSBRIDGE" SOLID SURFACE: CORIAN, "DEEP MINK" COVED STAINLESS STEEL BASE FINISHED END PANEL FINISHED BOTTOM PANEL WALL TILE: DAL TILE, MUSEO, "EXHIBITION WHITE, MU30" ACCENT TILE: DAL TILE, MUSEO, "ARTISTIC GREY, MU31" FRP PANEL: CRANE, SMOOTH, "WHITE" PL-1: PL-2: PL-3: PL-4: QZ-1: SS-1: ST-1: F/E: F/B: WT-1 AT-1 FP-1 I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 4 : 4 6 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A5.1 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . EN L A R G E D P L A N S A N D E L E V A T I O N S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE: 1/4" = 1'-0"A5.1 A ELEVATION SCALE: 1/4" = 1'-0"A5.1 B ELEVATION SCALE: 1/4" = 1'-0"A5.1 C ELEVATION SCALE: 1/4" = 1'-0"A5.1 D ELEVATION SCALE: 1/4" = 1'-0"A5.1 Y ELEVATION SCALE: 1/4" = 1'-0"A5.1 BB ELEVATION SCALE: 1/4" = 1'-0"A5.1 AA ELEVATION SCALE: 3/8" = 1'-0" A5.1 1 ENLARGED PLAN SCALE: 1/4" = 1'-0"A5.1 Z ELEVATION SCALE: 1/4" = 1'-0"A5.1 E ELEVATION SCALE: 1/4" = 1'-0"A5.1 F ELEVATION SCALE: 3" = 1'-0" A5.1 P DETAIL SCALE: 3" = 1'-0" A5.1 N DETAIL SCALE: 3" = 1'-0" A5.1 M DETAIL SCALE: 3" = 1'-0" A5.1 L DETAIL SCALE: 3/8" = 1'-0" A5.1 2 ENLARGED PLAN SCALE: 1/4" = 1'-0"A5.1 H ELEVATION SCALE: 3/8" = 1'-0" A5.1 3 ENLARGED PLAN SCALE: 1/4" = 1'-0"A5.1 Q ELEVATION SCALE: 1/4" = 1'-0"A5.1 R ELEVATION SCALE: 1/4" = 1'-0"A5.1 S ELEVATION SCALE: 1/4" = 1'-0"A5.1 T ELEVATION SCALE: 1/4" = 1'-0"A5.1 U ELEVATION SCALE: 1/4" = 1'-0"A5.1 V ELEVATION SCALE: 1/4" = 1'-0"A5.1 W ELEVATION SCALE: 1/4" = 1'-0"A5.1 X ELEVATION SCALE: 3" = 1'-0" A5.1 K DETAIL SCALE: 1/4" = 1'-0"A5.1 J ELEVATION FP-1 6'-10" 1' - 1 0 " A5.2 A 1"2 1/2"6'-3" 2 1/2" 1" A5.2B 1" 1 1 " 1 0 " A5.2 C 1' - 9 " 1" 46 1/2" 9 1 / 4 " D A5.2 GROMMET 3' - 6 " N A5.2 6'-10" 1"6'-8"1" 75" 2' - 1 1 / 2 " R 144" 5" PL-2 QZ-1 PL-1 PL-3 1'-9" 1'-10" 3' - 6 " 10 PL-3 QZ-1 PL-1 1'-10" 3' - 6 " 1'-9" PL-3 QZ-1 PL-1 10 4" 2 9 1 / 2 " 1 4 " 5 4 1 / 2 " 10 2 " 22 3/4" DRAWERS AND HARDWARE PULLS - SPACED EQUALLY (PL-1 FACE) PLASTIC LAMINATE BASE (PL-1) CABINET PULLS CABINET DOOR (PL-1) 3/4" ADJUSTABLE SHELF CEILING PLANE MICROWAVE N.I.C. VENTILATION FOR MICROWAVE - TYP. BOTH SIDES 3/4" SIDES AND BACK PANELS (PL-1) 4" 2 9 1 / 2 " 4 " 2 2 1 / 2 " 4 2 " 33 1 / 2 " 2 6 1 / 2 " 4 2 " 6" DRAWERS AND HARDWARE PULLS PLASTIC LAMINATE BASE (PL-1) CABINET PULLS CABINET DOOR (PL-1) 3/4" ADJUSTABLE SHELF - TYP. CEILING PLANE 10 2 " CABINET PULLS CABINET DOOR (PL-1) 3/4" ADJUSTABLE SHELF 24" PLASTIC LAMINATE COUNTER TOP WITH 4" BACK SPLASH (PL-2) 3/4" SIDE PANEL (PL-1) VENTILATION FOR MICROWAVE - TYP. BOTH SIDES 12" 22 3/4" 78 " 2 4 " 10 2 " 22 3/4" CABINET PULLS CABINET DOOR (PL-1) 3/4" ADJUSTABLE SHELF - TYP. CEILING PLANE REFRIGERATE - N.I.C. 4" COVED RUBBER BASE 4" 3 ' - 0 " 4 " 3' - 4 " DRAWERS AND HARDWARE PULLS - TYP. (PL-1 FACE) PLASTIC LAMINATE BASE (PL-1) 2'-0" PLASTIC LAMINATE COUNTERTOP WITH 4" BACK SPLASH (PL-2) 4" 3 ' - 0 " 4 " 3' - 4 " PLASTIC LAMINATE BASE (PL-1) 2'-0" PLASTIC LAMINATE COUNTERTOP WITH 4" BACK SPLASH (PL-2) 6" DRAWERS AND HARDWARE PULLS CABINET PULLS CABINET DOOR (PL-1) 3/4" ADJUSTABLE SHELF 2' - 1 1 1 / 2 " 3 " 1 1 / 2 " 2" 3' - 6 " 10" 10" 1"1" 4 1/2" COVED STAINLESS STEEL BASE (ST-1) (3 SIDES OF SUPPORT LEGS) 3/4" REMOVABLE PANEL (PL-1) 3/4" SHAPED ACCENT PANEL (PL-2) - SEE ELEVATION A/5.2 PLASTIC LAMINATE REVEAL PANEL (PL-3) QUARTZ COUNTERTOP (QZ-1) 1'-10" 1' - 6 " 10 " 2' - 0 3 / 4 " 3/ 4 " ALUMINUM Z-CLIPS MONARCH "MF375" - SEE DETAIL T/A5.2 (3 EACH TOP & BTM) PAINT EXPOSED FRAMING BLACK 3" END PANEL (PL-1) SEE R/A5.2 9 1/4" 2" 1" 7 1/4" 1" 6.6B 103'-10" T.O. FRAMING QUARTZ TOP (QZ-1) 16"60" A5.2 E A5.2F1' - 2 1 / 2 " 3" 1' - 2 1 / 2 " 2' - 8 " R 2'-0" R 6" 3' - 4 " 5'-0" P A5.2 R 1 0 8 " 10 PL-3 QZ-1 PL-4 PL-1PL-2 3' - 4 " 2'-8" Q A5.2 QZ-1PL-3 QZ-1 PL-1 2' - 1 0 " WALL-HUNG LAVATORY (PIPES WRAPPED) MIRROR* PAPER TOWEL DISPENSER* SOAP DISPENSER* WATER CLOSET TOILET PAPER AND/OR SANITARY NAPKIN DISPENSER GRAB BARS SIGNAGE DRINKING FOUNTAIN SINGLE BASIN SINK SEMI-RECESSED F.E. CABINET MOP SINK AND FAUCET MOP RACK FIXTURE & ACCESSORIES KEY **SEE ANSI MOUNTING HEIGHTS FOR FIXTURE AND ACCESSORIES ON SHEET G2.0** A B C D E F G H J K L M N *OWNER FURNISHED, CONTRACTOR INSTALLED 1. ALL DISPENSERS ARE OWNER FURNISHED - CONTRACTOR INSTALLED. 2. CABINET FINISH AND COUNTER TOPS SHALL BE PLASTIC LAMINATE - U.N.O.. SEE SCHEDULE BELOW. 3. PROVIDE SCHLUTER TILE TRIM AROUND ALL EXPOSED TILE EDGES, INTERIOR AND EXTERIOR TILED CORNERS, AND TILED WALL TO FLOOR CONDITIONS. 4. CONTRACTOR SHALL PROVIDE ACCESSORY TRIM PIECES FOR SCHLUTER TRIM. 5. GROMMET HOLE LOCATIONS, IN COUNTERTOPS, TO BE FIELD VERIFIED WITH OWNER PRIOR TO DRILLING. GENERAL NOTES INTERIOR KEYNOTES CABINET FILLER - ON UPPER CABINETS PROVIDE BOTTOM AND TOP FOR FILLER 12" DEEP UPPER CABINET 24" DEEP BASE CABINET 24" DEEP MICROWAVE CABINET PLASTIC LAMINATE COUNTERTOP PLASTIC LAMINATE BACKSPLASH QUARTZ COUNTERTOP (QZ-1) 20" DEEP CABINET (ELEC. CHASE BEHIND) BASE - SEE FINISH TAG SHEET A1.4 BASE - SEE CASEWORK SECTIONS 12" x 24" WALL TILE (WT-1) 2" x 2" MATT ACCENT TILE - 2 BANDS (AT-1) APPLIANCES - N.I.C. OFFICE EQUIPMENT - N.I.C. GROMMET - VERIFY LOCATION WITH OWNER GATE WITH BOMMER 3029-5 HINGES, SEE E/A5.3 3/4" PLASTIC LAMINATE ACCENT PANEL (PL-2) FRP (FP-1) WINDOW SYSTEM PAINTED METAL COUNTER TOP BRACKET DOOR AND HOLLOW METAL FRAME STOREFRONT SYSTEM PNEUMATIC TUBE SYSTEM BY OWNER - VERIFY ROUGH IN RECOMMENDATIONS FUTURE PNEUMATIC TUBE SYSTEM BY OWNER - VERIFY ROUGH IN RECOMMENDATIONS REMOVABLE 3/4" PANEL(S), MOUNT WITH Z-CLIPS ON 2x HORIZ. FRAMING SIM TO DETAIL M/A5.2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 4 1 / 2 " 2 ' - 2 1 / 2 " 7 1 / 2 " 1 1 / 2 " 2" 3' - 6 " 1" 1" 1'-0 1/2" 3" 1'-0 1/2" 1" 4 1/2" STAINLESS STEEL BASE (ST-1) TYPICAL 3/4" PANEL (PL-1) 3/4" SHAPED ACCENT PANEL (PL-2) PLASTIC LAMINATE REVEAL PANEL (PL-3) QUARTZ COUNTERTOP (QZ-1) 2'-6" 6" DRAWERS AND HARDWARE PULLS (PL-1 FACE) 1" 3" END PANEL (PL-1) SEE R/A5.2 2' - 1 0 " 4 1 / 2 " 1 1 / 2 " 2" 3' - 6 " 4 1/2" COVED STAINLESS STEEL BASE (ST-1) (TYP.) 3/4" PANEL (PL-1) 3/4" SHAPED ACCENT PANEL (PL-2) (BEYOND) PLASTIC LAMINATE REVEAL PANEL (PL-3) 5'-0" 3/4" SHAPED ACCENT PANEL (PL-2) (BEYOND) 3"3" 13 1/2" 10 " R 1'-8" PLASTIC LAMINATE WRAPPED COUNTER SUPPORTS (PL-4) QUARTZ COUNTERTOP (QZ-1) 1"1" 1" 4'-10" 1" 1'-5"1" 3/4" PANEL 3/4" PANEL (PL-1) 3/4" FINISHED PANEL (PL-1) TYPICAL 3 SIDES WOOD FRAMING 2' - 0 " 3" MILLWORK FINISH SCHEDULE P-LAM: WILSON ART, #7949K-18 "ASIAN NIGHT" P-LAM: PIONITE, #AT440, "CONNECTED CUBES" P-LAM: PIONITE, BLACK SE101 SUEDE P-LAM: FORMICA, "BRUSHED ARGENT M5311" QUARTZ: CAMBRIA, "IRONSBRIDGE" SOLID SURFACE: CORIAN, "DEEP MINK" COVED STAINLESS STEEL BASE FINISHED END PANEL FINISHED BOTTOM PANEL WALL TILE: DAL TILE, MUSEO, "EXHIBITION WHITE, MU30" ACCENT TILE: DAL TILE, MUSEO, "ARTISTIC GREY, MU31" FRP PANEL: CRANE, SMOOTH, "WHITE" PL-1: PL-2: PL-3: PL-4: QZ-1: SS-1: ST-1: F/E: F/B: WT-1 AT-1 FP-1 36 1/2"26"30"28"28" 28" 28" 30" 26" 35" 33 1 / 2 " 2 6 1 / 2 " 4 2 " 2' - 0 " 13 C K D 1 1222 4 1 3 3 3 5 6 9 G A5.2 H A5.2 J A5.2 (PL-2) (PL-2) (PL-1) (PL-1) (F/B) (F/E) 4" 3 ' - 0 " 3' - 4 " PLASTIC LAMINATE BASE (PL-1) 2'-0" PLASTIC LAMINATE COUNTERTOP (PL-2) 6" DRAWERS AND HARDWARE PULLS CABINET PULLS CABINET DOOR (PL-1) 3/4" ADJUSTABLE SHELF 20"4" OP E N E L E C T R I C A L C H A S E 2'-0" PLASTIC LAMINATE COUNTERTOP (PL-2) 2x4 FRAMING FROM CABINET TO WALL 3/4" REMOVABLE PANEL (PL-1) (54" LONG = (2) EQUAL PANELS) 2' - 9 3 / 4 " 3/ 4 " ALUMINUM Z-CLIPS MONARCH "MF375" - SEE T/A5.2 (2 EACH TOP & BTM OF EACH PANEL) 20"4" 4" 14 " DOOR BEYOND CABINET END PANEL (PL-1) OP E N E L E C T R I C A L C H A S E 12 " PLASTIC LAMINET BASE (PL-1) 2x6 FRAMING FROM CABINET TO WALL 2x CONTINUOUS FRAMING (VARIES) 3/4" REMOVABLE PANEL (HEIGHT & WIDTH VARIES) ALUMINUM Z-CLIP MONARCH "MF375" (# OF CLIPS VARIES)CH A S E S I D E I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 4 : 4 8 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A5.2 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . EN L A R G E D P L A N S , E L E V A T I O N S , A N D S E C T I O N S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE: 3/8" = 1'-0" A5.2 1 ENLARGED PLAN SCALE: 1/4" = 1'-0"A5.2 A ELEVATION SCALE: 1/4" = 1'-0"A5.2 B ELEVATION SCALE: 1/4" = 1'-0"A5.2 C ELEVATION SCALE: 1" = 1'-0" A5.2 G SECTION SCALE: 1" = 1'-0" A5.2 H SECTION SCALE: 1" = 1'-0" A5.2 J SECTION SCALE: 1" = 1'-0" A5.2 K SECTION SCALE: 1" = 1'-0" A5.2 L SECTION SCALE: 1" = 1'-0" A5.2 N SECTION SCALE: 1 1/2" = 1'-0" A5.2 D SECTION SCALE: 3/8" = 1'-0" A5.2 2 ENLARGED PLAN SCALE: 1/4" = 1'-0"A5.2 E ELEVATION SCALE: 1/4" = 1'-0"A5.2 F ELEVATION SCALE: 1" = 1'-0" A5.2 P SECTION SCALE: 1" = 1'-0" A5.2 Q SECTION SCALE: 1" = 1'-0" A5.2 R SECTION ALL CABINET PANELS, SHELVES, DRAWERS, AND DOORS SHALL BE 3/4" THICK PLASTIC LAMINATE COVERED SCALE: 3/8" = 1'-0" A5.2 3 ELEVATION SCALE: 1" = 1'-0" A5.2 M SECTION SCALE: 1" = 1'-0" A5.2 S SECTION SCALE: 3" = 1'-0" A5.2 T Z-CLIP DETAIL ALL CABINET PANELS, SHELVES, DRAWERS, AND DOORS SHALL BE 3/4" THICK PLASTIC LAMINATE COVERED 3' - 4 " 4 1/2" ALUMASTEEL LAMINATE BASE (PL-4) 3/4" FINISH PANEL (PL-1) 5' - 6 " 1 1 / 2 " 2" 11" 2" 6" 3 " 5" 5" 2'-9 1/2" 5' - 3 7 / 8 " PLASTIC LAMINATE WRAPPED COUNTER SUPPORTS (PL-4) QUARTZ COUNTERTOP (QZ-1) R 3'-4" PLASTIC LAMINATE WRAPPED DIVIDER (PL-4) PLASTIC LAMINATE WRAPPED WALL CAP (PL-4) 1 1 / 2 " R 1 0 " PLASTIC LAMINATE WRAPPED DIVIDER (PL-4) 4 1/2" STAINLESS STEEL BASE (ST-1) 4' - 1 0 " 4 1/2" ALUMASTEEL LAMINATE BASE (PL-4) 3/4" FINISH PANEL (PL-1) 5' - 6 " 1 1 / 2 " 2" 11" 2" 4" 8" 5' - 3 7 / 8 " PLASTIC LAMINATE WRAPPED COUNTER SUPPORTS (PL-4) QUARTZ COUNTERTOP (QZ-1) R 3'-4" PLASTIC LAMINATE WRAPPED WALL CAP (PL-4) (ALL SIDES) 3/4" SHAPED ACCENT PANEL (PL-2) 1 1 / 2 " 3' - 4 " 1'-11" 1 1/4"1" 5" 4 1/2" STAINLESS STEEL BASE (ST-1) 58 " 3/4" FINISH PANELS (PL-1) 4 1/2" 1 1 / 2 " 40 " 2 1/2" 2'-1" 1 1 / 2 " 1"1"QUARTZ COUNTERTOP (QZ-1) 4 1/2" ALUMASTEEL LAMINATE BASE (PL-4) 6" DRAWERS, HARDWARE, AND PULLS CABINET PULLS CABINET DOOR (PL-1) 3/4" ADJUSTABLE SHELF 4 1 / 2 " 4 1/2" STAINLESS STEEL BASE (ST-1) 6" 2 ' - 4 " 4 1/2" COVED STAINLESS STEEL BASE (BEYOND) 3/4" FINISH PANEL (PL-1) QUARTZ COUNTERTOP (QZ-1) 2 1/4" 1 1 / 2 " 4 1/2" 3/4" SHAPED ACCENT PANEL (PL-2)NOT USED2' - 1 0 " LOCKING DRAWERS, HARDWARE, AND PULLS QUARTZ COUNTERTOP (QZ-1) 2'-6" LOCKING DRAWERS, HARDWARE, AND PULLS 4 1 / 2 " 4 1/2" ALUMASTEEL LAMINATE BASE (PL-4) (TYPICAL 3 SIDES) FINISHED FACE (TYP. 3 SIDES) (PL-1)NOT USEDMILLWORK FINISH SCHEDULE P-LAM: WILSON ART, #7949K-18 "ASIAN NIGHT" P-LAM: PIONITE, #AT440, "CONNECTED CUBES" P-LAM: PIONITE, BLACK SE101 SUEDE P-LAM: FORMICA, "BRUSHED ARGENT M5311" QUARTZ: CAMBRIA, "IRONSBRIDGE" SOLID SURFACE: CORIAN, "DEEP MINK" COVED STAINLESS STEEL BASE FINISHED END PANEL FINISHED BOTTOM PANEL WALL TILE: DAL TILE, MUSEO, "EXHIBITION WHITE, MU30" ACCENT TILE: DAL TILE, MUSEO, "ARTISTIC GREY, MU31" FRP PANEL: CRANE, SMOOTH, "WHITE" PL-1: PL-2: PL-3: PL-4: QZ-1: SS-1: ST-1: F/E: F/B: WT-1 AT-1 FP-1 I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 4 : 4 9 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A5.3 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . CA S E W O R K D E T A I L S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE: 1" = 1'-0" A5.3 A SECTION SCALE: 1" = 1'-0" A5.3 B SECTION SCALE: 1" = 1'-0" A5.3 C SECTION SCALE: 1" = 1'-0" A5.3 E SECTION SCALE: 1" = 1'-0" A5.3 F SECTION SCALE: 1" = 1'-0" A5.3 G SECTION SCALE: 1" = 1'-0" A5.3 D SECTION ALL CABINET PANELS, SHELVES, DRAWERS, AND DOORS SHALL BE 3/4" THICK PLASTIC LAMINATE COVERED 6 A 7 1 / 4 " 5 1/4"406 412 503 510 1' - 4 " 1'-8" 601 906 604 603 724 6 B 7 1 / 4 " 406 801 603 503 412 1'-4" 1' - 4 " 604 601 E 5 1' - 4 " 8 1/2" 406 603 603 1'-4" 8" 8 " 801 801 504 624 709 3 E 406 1'-4" 801 624 624 624 906 603 406 709 4 1 / 8 " 3/ 4 " 510 3 1' - 4 " 2'-0" 4 1/2" 406 412 603 406 4" 2 1 / 2 " 4 1 / 8 " 1 1 7 / 8 " 4 3 / 4 " 1/ 2 " 5 1 / 2 " 1/ 2 " 4 3 / 4 " 4 3/8" 1/2" 1'-2 1/4" 1/2" 4 3/8"624 709 4 B 7" 8"8" 406 603 906 624 801 709 624 504 4 412 603 406 624709 603 906 709 906 624 6 E 3 3/4" 8"x8" ALUMINUM COLUMN COVER TO MATCH STOREFRONT MATERIAL 503 503 4 1/4"3 3/4" 414 604 5 1 / 4 " 3 " 601 414 5 2'-0" 1' - 4 " 412 406 4 1/2" 406 603 4" 624 4 3 / 4 " 1/ 2 " 5 1 / 2 " 1/ 2 " 4 3 / 4 " 4 3/8"1/2"1'-2 1/4"1/2"4 3/8" 801 709 624 B 5 624 906 906 603 906 906 800 800 709 624 504 4 E 1'-1"4'-7"1'-1"8 1/2" DETAIL ABOVE CEILING LEVEL OF OFFICES. DETAIL FROM ELEVATION 110'-8" TO 114'-8" 624 906 624 906 709504 6 C 406 603 801 414 604 414 414 603 709 406 4 B 906 906 906 906 603 906 800 800 624 709 709 504 4 E 801 624 801709 ALUMINUM BREAK METAL - MATCH WINDOW FRAME 906 603 1 3/4" 3" 3 5 / 8 " 504 4 801 906 603 714 624 I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 4 : 5 3 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A5.4 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . FL O O R P L A N D E T A I L S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE: 1" = 1'-0" A5.4 A DETAIL SCALE: 1" = 1'-0" A5.4 B DETAIL SCALE: 1" = 1'-0" A5.4 J DETAIL SCALE: 1" = 1'-0" A5.4 K DETAIL SCALE: 1" = 1'-0" A5.4 L DETAIL SCALE: 1" = 1'-0" A5.4 F DETAIL SCALE: 1" = 1'-0" A5.4 H DETAIL KEYNOTE LEGEND NO. KEYNOTE 406 BRICK VENEER 412 4" MANUFACTURED STONE VENEER 414 MANUFACTURED STONE SILL 503 STEEL TUBE - PAINTED WHERE EXPOSED - SEE STRUCTURAL 504 STEEL COLUMN - PAINTED WHERE EXPOSED - SEE STRUCTURAL 510 STEEL PIPE COLUMN - PAINTED WHERE EXPOSED - SEE STRUCTURAL 601 2X WOOD FRAMING 603 WOOD SHEATHING 604 SOLID SURFACE SILL 624 2X6 FRAMING 709 BATT INSULATION FULL THICKNESS 714 PRE-FINISHED CONT. METAL FLASHING 724 BACKER ROD AND SEALANT 800 DOOR & FRAME 801 ALUMINUM WINDOW SYSTEM 906 5/8" GYPSUM BOARD SCALE: 1" = 1'-0" A5.4 D DETAIL SCALE: 1" = 1'-0" A5.4 N DETAIL SCALE: 1" = 1'-0" A5.4 M DETAIL SCALE: 1/2" = 1'-0" A5.4 G DETAIL SCALE: 1" = 1'-0" A5.4 C DETAIL SCALE: 1" = 1'-0" A5.4 E DETAIL SCALE: 1" = 1'-0" A5.4 P DETAIL SCALE: 1" = 1'-0" A5.4 Q DETAIL 22'-6" 3' - 0 " 4 ' - 7 " 87 " EQ EQ EQ 11'-4" 11'-2" EQ EQ EQ A A A A A A A A A A A A S A6.2 J A6.2 D A6.2 M A6.2 V A6.2 J A6.2 K A6.2 9' - 1 1 1 / 8 " 2 ' - 3 7 / 8 " 4 ' - 1 0 5 / 8 " 11 ' - 1 5 / 8 " 17 ' - 1 1 / 2 " INTERIOR SHADE LOCATION R 30'-6" A 5"5" 5" 6 1 / 2 " SE E S C H E D U L E SCHEDULE SEE B 5"5" 2' - 7 " 5 " SE E S C H E D U L E SCHEDULE SEE C SE E S C H E D U L E SCHEDULE SEE A T B T OR B T D 5"5" 5" SE E S C H E D U L E SCHEDULE SEE B T 6" SHELF WITH SUPPORTS 3' - 6 " 3' - 6 " 2' - 7 " G A6.2 Q A6.2 6 1 / 2 " 40 " 52 " 84 " 98 " 118" EQ EQ EQ 36" B T B T B T B B B T B B B T B B B B 127" G A6.2 Q A6.2 6 1 / 2 " 84 " 52 " 40 " 98 " EQ EQ EQ 3'-0" B T B T B T B T B B B T B B B B BB 137" 36 " 6 7 " EQ EQ EQ A A A S A6.2 A A6.2 J A6.2 A A6.2 36 " 5 5 " 13 0 " A A A J A6.2 S A6.2 72 1/16" 87 " 84 " 123" 25 1/2"72"25 1/2" REMOVABLE MULLION BEHIND DOORS ON DOOR 101A A T B T OR A T B T OR 6 1 / 2 " R 1 8 ' - 6 1 / 2 " A B OR P A6.2 10 7 3 / 4 " F A6.2 11 6 3 / 8 " 36 " 5 5 " 13 0 " EQEQEQ 156" A A A A A A A A A S A6.2 A A6.2 J A6.2 M A6.2 87 "10'-11" 29 1/2"72"29 1/2" AA A X A6.2 A A6.2 J A6.2 36 " R 20'-8 5/8" GLAZING TYPE KEY A 1" TINTED INSULATED GLAZING 1/4" CLEAR FLOAT GLAZING TEMPERED GLAZING GLASS-FACED SPANDREL PANEL - GLASS TO MATCH ADJACENT GLASS TINT B T C 36" 48 " 3 6 " A W A6.2 E A6.2 N A6.2 24" 36 " 5 5 " A A W A6.2 J A6.2 EE A6.2 84 " C 98 " H A6.2 R A6.2 52 " 84 " 98 " 113" B B B T B B B T B B B B 3'-0" 40 " EQ EQ EQ Z A6.2 6 1 / 2 " 40 " 52 " 84 " 96 " 12 0 " 121" EQ EQ 3'-0" B T B T B T B B T B B BB B BB AA A6.2 JJ A6.2 SS A6.2 3' - 4 " 3 ' - 0 " 10'-0" DRIVE-THRU WINDOW AND ACCESSORIES BY OWNER U A6.2 C A6.2 L A6.2 FF A6.2 PP A6.2 3'-0" 7' - 0 " 6 1 / 2 " 40 " 52 " 84 " 96 " 12 0 " 125" EQ EQ 3'-0" B T B T B B T B B T B B B B B B SS A6.2 TT A6.2 AA A6.2 119 1/2" 19 " A A T A6.2 B A6.2 K A6.2 EQ EQ NN A6.2 315 7' - 0 " 2" 2"3'-0"2" BB A6.2 KK A6.2 CC A6.2 LL A6.2 DD A6.2 MM A6.2 I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 4 : 5 8 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A6.1 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . DO O R S C H E D U L E & E L E V A T I O N S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN DOOR SCHEDULE DO O R N U M B E R DO O R H A N D I N G LOCATION SIZE SI N G L E O R P A I R DO O R T Y P E FR A M E T Y P E MATERIAL FI R E R A T I N G REMARKS FROM TO WI D T H HE I G H T DO O R FR A M E RO O M # NA M E RO O M # NA M E 101A RHR/LHR EXT. EXT. 101 VESTIBULE 6'-0" 7'-0" P A 303 ALUM ALUM REMOVABLE MULLION 101B RHR/LHR 101 VESTIBULE 102 MAIN LOBBY 6'-0" 7'-0" P A 303 ALUM ALUM 103 LH 102 MAIN LOBBY 103 MANAGER 3'-0" 7'-0" S A 309 ALUM ALUM 104 RH 102 MAIN LOBBY 104 OFFICE 1 3'-0" 7'-0" S A 310 ALUM ALUM 106 RH 102 MAIN LOBBY 106 DRIVE-THRU 3'-0" 7'-0" S D 311 ALUM ALUM DUTCH DOOR w/SHELF 107 RH 108 HALLWAY 107 BREAK 3'-0" 7'-0" S B 315 WOOD HM 108 RHR EXT. EXT. 108 HALLWAY 3'-0" 7'-0" S A 314 ALUM ALUM 111 RH 112 JAN./STOR. 111 MECH. 3'-0" 7'-0" S C 315 WOOD HM 112 LHR 102 MAIN LOBBY 112 JAN./STOR. 3'-0" 7'-0" S C 315 WOOD HM 113 LH 102 MAIN LOBBY 113 OFFICE 2 3'-0" 7'-0" S A 312 ALUM ALUM 115 RH 102 MAIN LOBBY 115 OFFICE 3 3'-0" 7'-0" S A 313 ALUM ALUM 117 RH 108 HALLWAY 117 TOILET 3'-0" 7'-0" S C 315 WOOD HM 118 LH 108 HALLWAY 118 TOILET 3'-0" 7'-0" S C 315 WOOD HM 305 SCALE: 1/4" = 1'-0" DOOR TYPE 310309 301 302 303 304303A 307 306 311 312 308 314 313 303B SCALE: 1/4" = 1'-0" FRAME TYPES AND WINDOW STOREFRONTS 6 4" 5/8" GYP. BOARD WOOD BLOCKING STEEL BEAM - SEE STRUCTURAL BACKER ROD AND SEALANT - BOTH SIDES 4 1/2" ALUMINUM WINDOW FRAME SOFFIT FRAMING PRE- FINISHED METAL SOFFIT AND J-CHANNEL SUN SHADE 3 1 / 4 " EXTERIOR SIDE STEEL COLUMN - SEE STRUCTURAL BACKER ROD AND SEALANT - BOTH SIDES 4 1/2" ALUMINUM WINDOW FRAME WOOD SHEATHING MASONRY VENEER 2" 3 1/4" 8 1/8" 3" 2 " MASONRY VENEER MASONRY SILL 1/2" WOOD SHEATHING 4 1/2" ALUMINUM WINDOW FRAME BACKER ROD AND SEALANT - BOTH SIDES SOLID SURFACE SILL 1" 2X6 WOOD STUDS - INSULATED STEEL BEAM - SEE STRUCTURAL E 6 ALUMINUM BREAK METAL TO MATCH STOREFRONT BACKER ROD AND SEALANT - BOTH SIDES WOOD BLOCKING - AS REQUIRED 4 1/2" ALUMINUM WINDOW FRAME BACKER ROD AND SEALANT - BOTH SIDES 8" 8" COLUMN - SEE STRUCTURAL 1 3/4" ROOF SHEATHING STANDING METAL SEAM ROOF PRE-FINISHED METAL FLASHING 2X6 WOOD STUDS - INSULATED 4 1/2" ALUMINUM WINDOW FRAME 5/8" GYP. BOARD BACKER ROD AND SEALANT - BOTH SIDES 1/2" WOOD SHEATHING1" 5/8" GYP. BOARD4 9/16" 4 EQ EQ STEEL BEAM - SEE STRUCTURAL 5/8" GYP. BOARD ON TRUSS BOTTOM CHORD 4 1/2" ALUMINUM WINDOW FRAME WOOD BLOCKING BACKER ROD AND SEALANT - BOTH SIDES SOFFIT FRAMING AND PRE-FINISHED METAL SOFFIT AND J- CHANNEL 4 1/2" ALUMINUM WINDOW FRAME BACKER ROD AND SEALANT - BOTH SIDES 2X6 WOOD STUDS - INSULATED ALUMINUM BREAK METAL - MATCH WINDOW FRAME 5/8" GYP. BOARD 1/2" WOOD SHEATHING 3/ 4 " 1 3/4" 4 1/2" ALUMINUM WINDOW FRAME 3 1/2" FA C E O F S T U D A6.2 Y METAL FILLER BETWEEN SEAMS ROOF SHEATHING STANDING METAL SEAM ROOF PRE-FINISHED METAL FLASHING 2X6 WOOD STUDS - INSULATED 4 1/2" ALUMINUM WINDOW FRAME 5/8" GYP. BOARD BACKER ROD AND SEALANT - BOTH SIDES (2) 1/2" WOOD SHEATHING E BACKER ROD AND SEALANT - BOTH SIDES ROOF JOIST - SEE STRUCTURAL WOOD BLOCKING 5/8" GYP. BOARD 4 1/2" ALUMINUM WINDOW FRAME SOFFIT FRAMING AND PRE-FINISHED METAL SOFFIT AND J- CHANNEL 1 3/16" SUN SHADE 5/8" GYP. BOARD 5/8" GYP. BOARD 2X6 WOOD STUDS - INSULATED BACKER ROD AND SEALANT - BOTH SIDES 4 1/2" ALUMINUM FRAME 2X6 WOOD STUDS - INSULATED HEADER - SEE STRUCTURAL BACKER ROD AND SEALANT - BOTH SIDES 4 1/2" ALUMINUM FRAME 5/8" GYP. BOARD EQ EQ MASONRY VENEER 1/2" WOOD SHEATHING 2X6 WOOD STUDS - INSULATED 4 1/2" ALUMINUM WINDOW FRAME BACKER ROD AND SEALANT - BOTH SIDES PRE-FINISHED METAL SOFFIT AND J-CHANNEL FILL CAVITY WITH INSULATION 4 1/2" ALUMINUM WINDOW FRAME BACKER ROD AND SEALANT - BOTH SIDES ROOF JOISTS MASONRY VENEER 1/2" SHEATHING 5/8" GYP. BOARD 2X6 WOOD STUDS - INSULATED 4 1/2" ALUMINUM WINDOW FRAME BACKER ROD AND SEALANT - BOTH SIDES 3" MASONRY VENEER 1/2" WOOD SHEATHING HEADER - SEE STRUCTURAL 2X6 WOOD STUDS - INSULATED PAINTED STEEL ANGLE - SEE STRUCTURAL 4 1/2" ALUMINUM WINDOW FRAME BACKER ROD AND SEALANT - BOTH SIDES MAX. 3"SUN SHADE MASONRY VENEER 1/2" WOOD SHEATHING HEADER - SEE STRUCTURAL DRIVE-THRU WINDOW AND TRIM BY OWNER 2X6 WOOD STUDS - INSULATED STEEL ANGLE - SEE STRUCTURAL 5/8" GYP. BOARD ROLLED SHADE MASONRY VENEER 1/2" WOOD SHEATHING 5/8" GYP. BOARD DRIVE-THRU WINDOW AND TRIM BY OWNER 2X6 WOOD STUDS - INSULATED SOLID SURFACE 1" MASONRY VENEER 1/2" WOOD SHEATHING 5/8" GYP. BOARD DRIVE-THRU WINDOW AND TRIM BY OWNER 2X6 WOOD STUDS - INSULATED 5/8" GYP. BOARD WOOD FRAMING FOR SOFFIT AND CEILINGS WOOD BEAM - SEE STRUCTURAL BACKER ROD AND SEALANT - BOTH SIDES 4 1/2" ALUMINUM WINDOW FRAME ALUMINUM BREAK METAL TO MATCH FRAME 5/8" GYP. BOARD 1/2" WOOD SHEATHING SUN SHADE DRIVE-THRU ROOM 106 2X6 WOOD STUDS - INSULATED HEADER - SEE STRUCTURAL BACKER ROD AND SEALANT - BOTH SIDES 4 1/2" ALUMINUM FRAME 5/8" GYP. BOARD 4 1/2" 2 1/4" DRIVE-THRU ROOM 106 5/8" GYP. BOARD 5/8" GYP. BOARD 2X6 WOOD STUDS - INSULATED BACKER ROD AND SEALANT - BOTH SIDES 4 1/2" ALUMINUM FRAME WOOD HEADER - SEE STRUCTURAL CAULK AROUND FRAME - BOTH SIDES 8 1/4" H.M. FRAME - INSULATED DOOR PANEL 2X6 WOOD STUDS - INSULATED 1/2 SHEATHING - SEE STRUCTURAL 5/8" GYP. BOARD2X WOOD FRAMING WOOD HEADER - SEE STRUCTURAL BACKER ROD AND SEALANT - BOTH SIDES 4 3/4" ALUMINUM FRAME 6" 2 " 1" 1/2" 5/8" GYP. BOARD R 1/2" 2X6 WOOD STUD - INSULATED BACKER ROD AND SEALANT - BOTH SIDES 4 1/2" ALUMINUM FRAME 5/8" GYP. BOARD 4 7 / 8 " 2X6 WOOD STUD - INSULATED BACKER ROD AND SEALANT - BOTH SIDES 4 1/2" ALUMINUM FRAME 5/8" GYP. BOARD 2X6 WOOD STUD - INSULATED BACKER ROD AND SEALANT - BOTH SIDES 4 1/2" ALUMINUM FRAME 5/8" GYP. BOARD CAULK AROUND FRAME - BOTH SIDES 8 1/4" H.M. FRAME - INSULATED DOOR PANEL 2X6 WOOD STUDS - INSULATED 1/2 SHEATHING - SEE STRUCTURAL 5/8" GYP. BOARD WOOD HEADER - SEE STRUCTURAL CAULK AROUND FRAME - BOTH SIDES 7 3/4" H.M. FRAME - INSULATED DOOR PANEL 2X6 WOOD STUDS - INSULATED 5/8" GYP. BOARD CAULK AROUND FRAME - BOTH SIDES 7 3/4" H.M. FRAME - INSULATED DOOR PANEL 2X6 WOOD STUDS - INSULATED 1/2 SHEATHING - SEE STRUCTURAL 5/8" GYP. BOARD TILE WHERE OCCURS - PROVIDE 5/8" BACKER BOARD WOOD HEADER - SEE STRUCTURAL CAULK AROUND FRAME - BOTH SIDES 5 3/4" H.M. FRAME - INSULATED DOOR PANEL 2X6 WOOD STUDS - INSULATED 5/8" GYP. BOARD CAULK AROUND FRAME - BOTH SIDES 5 3/4" H.M. FRAME - INSULATED DOOR PANEL 2X6 WOOD STUDS - INSULATED 5/8" GYP. BOARD TILE WHERE OCCURS - PROVIDE 5/8" BACKER BOARD WIDTH VARIES 1" 3/ 4 " 1 1 / 4 " 3" 3/4"3/4" PAINTED WOOD 2" 3 1/4" 8 1/8" 3" 2 " MASONRY VENEER MASONRY SILL 1/2" SHEATHING 4 1/2" ALUMINUM WINDOW FRAME BACKER ROD AND SEALANT - BOTH SIDES SOLID SURFACE SILL 1" 2X6 WOOD STUDS - INSULATED ROOF SHEATHING STANDING METAL SEAM ROOF PRE-FINISHED METAL FLASHING 2X8 WOOD STUDS 4 1/2" ALUMINUM WINDOW FRAME BACKER ROD AND SEALANT - BOTH SIDES WOOD SHEATHING 1" VAPOR BARRIER AIR BARRIER WRAP INTO OPENING MASONRY VENEER 1/2" SHEATHING 5/8" GYP. BOARD 2X6 WOOD STUDS - INSULATED 4 1/2" ALUMINUM WINDOW FRAME BACKER ROD AND SEALANT - BOTH SIDES PRE-FINISHED METAL FLASHING DRIVE-THRU ROOM 106 5/8" GYP. BOARD 5/8" GYP. BOARD 2X6 WOOD STUDS - INSULATED BACKER ROD AND SEALANT - BOTH SIDES 4 1/2" ALUMINUM FRAME SOLID SURFACE SILL MASONRY VENEER 1/2" WOOD SHEATHING HEADER - SEE STRUCTURAL 2X6 WOOD STUDS - INSULATED PAINTED STEEL ANGLE - SEE STRUCTURAL 4 1/2" ALUMINUM DOOR FRAME BACKER ROD AND SEALANT - BOTH SIDES MASONRY VENEER 1/2" SHEATHING 5/8" GYP. BOARD 2X6 WOOD STUDS - INSULATED 4 1/2" ALUMINUM DOOR FRAME BACKER ROD AND SEALANT - BOTH SIDES 3" I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 5 : 0 1 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A6.2 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . DO O R A N D W I N D O W D E T A I L S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE: 1 1/2" = 1'-0" A6.2 A HEADER SCALE: 1 1/2" = 1'-0" A6.2 J JAMB SCALE: 1 1/2" = 1'-0" A6.2 S SILL SCALE: 1 1/2" = 1'-0" A6.2 M JAMB SCALE: 1 1/2" = 1'-0" A6.2 V SILL SCALE: 1 1/2" = 1'-0" A6.2 B HEADER SCALE: 1 1/2" = 1'-0" A6.2 K JAMB SCALE: 1 1/2" = 1'-0" A6.2 T SILL SCALE: 1 1/2" = 1'-0" A6.2 D HEADER SCALE: 1 1/2" = 1'-0" A6.2 Q JAMB SCALE: 1 1/2" = 1'-0" A6.2 G HEADER SCALE: 1 1/2" = 1'-0" A6.2 P JAMB SCALE: 1 1/2" = 1'-0" A6.2 F HEADER SCALE: 1 1/2" = 1'-0" A6.2 N JAMB SCALE: 1 1/2" = 1'-0" A6.2 E HEADER SCALE: 1 1/2" = 1'-0" A6.2 C HEADER SCALE: 1 1/2" = 1'-0" A6.2 U SILL SCALE: 1 1/2" = 1'-0" A6.2 L JAMB SCALE: 1 1/2" = 1'-0" A6.2 EE HEADER SCALE: 1 1/2" = 1'-0" A6.2 H HEADER SCALE: 1 1/2" = 1'-0" A6.2 R JAMB SCALE: 1 1/2" = 1'-0" A6.2 BB HEADER SCALE: 1 1/2" = 1'-0" A6.2 AA HEADER SCALE: 1 1/2" = 1'-0" A6.2 JJ JAMB SCALE: 1 1/2" = 1'-0" A6.2 SS JAMB SCALE: 1 1/2" = 1'-0" A6.2 TT JAMB SCALE: 1 1/2" = 1'-0" A6.2 KK JAMB SCALE: 1 1/2" = 1'-0" A6.2 CC HEADER SCALE: 1 1/2" = 1'-0" A6.2 LL JAMB SCALE: 1 1/2" = 1'-0" A6.2 DD HEADER SCALE: 1 1/2" = 1'-0" A6.2 MM JAMB SCALE: 3" = 1'-0" A6.2 Y DETAIL SCALE: 1 1/2" = 1'-0" A6.2 W SILL SCALE: 1 1/2" = 1'-0" A6.2 X SILL SCALE: 1 1/2" = 1'-0" A6.2 NN JAMB SCALE: 1 1/2" = 1'-0" A6.2 Z JAMB SCALE: 1 1/2" = 1'-0" A6.2 FF HEADER SCALE: 1 1/2" = 1'-0" A6.2 PP JAMB 6 4 3 1 2 AB D E 5 C SL O P E = 1" / 1 ' - 0 " CU R V E D R O O F SL O P E V A R I E S CU R V E D R O O F SL O P E V A R I E S CU R V E D R O O F SL O P E V A R I E S CU R V E D R O O F SL O P E V A R I E S CU R V E D R O O F SL O P E V A R I E S CU R V E D R O O F SL O P E V A R I E S SL O P E = 1" / 1 ' - 0 " AABBCC 3.5 4.8 1.5 A A7.2 H A7.2 B A7.2 C A7.2 D A7.2 E A7.2 F A7.2 719 719 719 J A7.2 SIM L A7.2 M A7.2 R A7.2 3/8" / 1'-0" 7/ 8 " / 1 ' - 0 " 2'-1 3/8" 3' - 2 " 5/8" / 1'-0" 3' - 2 " 1' - 6 " 1 ' - 6 " 5'-0" 5/8" / 1'-0" Q A7.2 T A7.2 T A7.2 P A7.2 Sim P A7.2 Sim R03 R01 R01 R01 R01 LOWER ROOF N A7.2 LOWER ROOF LOWER ROOF G A7.2 LOWER ROOF K A7.2 S A7.2 LOWER ROOF R01 R02 R02 R02 ROOF CRICKETS ROOF CRICKETS 719 719 H A7.2 R03 E A7.2 K A7.2 K A7.2 D A7.2 R A7.2 ROOF DRAINS - SEE PLUMBING CURVED ROOF SLOPE VARIES CURVED ROOF SLOPE VARIES 1/2" / 1'-0" 5 / 8 " / 1 '- 0 " 1/4" / 1'-0" 3 /8 " / 1 '-0 " 3 / 8 " / 1 '- 0 " 5/8" / 1'-0" 3/8" / 1'-0" 5 / 8 " / 1 ' - 0 " 5/8" / 1'-0" 1 /2 " / 1 '-0 " 3/8" / 1'-0" NOTE: VALLEYS SHALL HAVE A NET MINIMUM SLOPE OF 1/4" PER 12" 1 / 4 " / 1'- 0 " SNOW RAILS - SEE SPECIFICATIONS INSTALL PER MANUFACTURERS DIRECTIONS SNOW RAILS - SEE SPECIFICATIONS INSTALL PER MANUFACTURERS DIRECTIONS I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 5 : 0 4 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A7.1 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RO O F P L A N MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE: N 1/4" = 1'-0" ROOF PLAN KEYNOTE LEGEND NO. KEYNOTE 719 PRE-FINISHED METAL GUTTER 4 STANDING SEAM METAL ROOF PRE-FINISHED METAL FASCIA ROOF SHEATHING 2X WOOD FRAMING PRE-FINISHED METAL SOFFIT 2X WOOD BLOCKING - FASTENED TO STEEL BEAM STEEL BEAM AND WOOD TRUSS PLATE- SEE STRUCTURAL STOREFRONT SYSTEM BARREL TRUSS - 55'-0" RADIUS T.O. TOP CORD - FILLED WITH INSULATION R01 PRE-FINISHED METAL DRIP EDGE R-13 INSULATION 1'-8" 1' - 2 " 4 A6.2 Y STANDING SEAM METAL ROOF ROOF SHEATHING 2X WOOD FRAMING 2X6 WOOD FRAMING - FASTENED TO STEEL BEAM STEEL BEAM AND WOOD TRUSS PLATE- SEE STRUCTURAL STOREFRONT SYSTEM BARREL TRUSS - 55'-0" RADIUS T.O. TOP CORD - FILLED WITH INSULATION INSULATION 1/ 2 " 4 " 4 " 8" 1 1/2" 6 3/4" 1/2" 1/2" 9" 1/2" 1/2" 11" PRE-FINISHED METAL FLASHING WOOD TRIM SHEATHING 5/8" GYP. BOARD 1/2" / 1'-0" 1' - 6 " 1 ' - 7 " PRE-FINISHED METAL DRIP EDGE AND HOLD DOWN CLIP PRE-FINISHED METAL FASCIA 2X8 WOOD FRAMING SHEATHING - TYP. PRE-FINISHED METAL FASCIA PRE-FINISHED METAL SOFFIT WOOD TRUSSES - SEE STRUCTURAL ROOF SHEATHING COVER BOARD TAPERED INSULATION SINGLE PLY MEMBRANE ROOFING SPM TO GO UP AND OVER PARAPET SHEATHING - TYP. 2X4 WOOD FRAMING 2 R01 R02 1'-2" BARREL TRUSS - 55'-0" RADIUS T.O. TOP CORD - FILL ED WITH INSULATION STANDING SEAM METAL ROOF ROOF SHEATHING R-13 INSULATION 2X WOOD FRAMING PRE-FINISHED METAL DRIP EDGE WOOD TRUSS PLATE- SEE STRUCTURAL PRE-FINISHED METAL FASCIA PRE-FINISHED METAL SOFFIT STANDING SEAM METAL ROOF ROOF SHEATHING PRE-FINISHED FLASHING ROOF JOIST AND BEAM - SEE STRUCTURAL - FILLED WITH INSULATION 5/8" GYP. BOARD WALL SHEATHING LSL RIM BOARD 1'-6" 1'-6" 1" / 1'-0" R02 ROOF JOIST AND BEAM - SEE STRUCTURAL - FILLED WITH INSULATION ROOF SHEATHING STANDING SEAM METAL ROOF PRE-FINISHED METAL DRIP EDGE PRE-FINISHED METAL GUTTER PRE-FINISHED METAL FASCIA LSL RIM BOARD 1'-2" PRE-FINISHED METAL SOFFIT 2X WOOD FRAMING MASONRY VENEER - BRICK OR CONCRETE 6 BARREL TRUSS - 55'-0" RADIUS T.O. TOP CORD - FILLED WITH INSULATION 1'-9 1/2" WOOD TRUSS PLATE - SEE STRUCTURAL R-13 INSULATION STANDING SEAM METAL ROOF ROOF SHEATHING PRE-FINISHED METAL DRIP EDGE PRE-FINISHED METAL GUTTER PRE-FINISHED METAL FASCIA LSL RIM BOARD 2X WOOD FRAMING 1 '- 2 " PRE-FINISHED METAL SOFFIT STEEL BEAM - SEE STRUCTURAL 4 R01 R01 1'-6" 1' - 2 " STANDING SEAM METAL ROOF ROOF SHEATHING BARREL TRUSS - 55'-0" RADIUS T.O. TOP CORD - FILLED WITH INSULATION PRE-FINISHED METAL DRIP EDGE PRE-FINISHED METAL FASCIA LSL RIM BOARD 2X WOOD FRAMING R-13 INSULATION PRE-FINISHED METAL SOFFIT PRE-FINISHED METAL FLASHING WALL SHEATHING - TYP. STANDING SEAM METAL ROOF ROOF SHEATHING BARREL TRUSS - 55'-0" RADIUS T.O. TOP CORD - FILLED WITH INSULATION 1' - 7 " 1 ' - 6 " PRE-FINISHED METAL DRIP EDGE AND HOLD DOWN CLIP 2X8 WOOD FRAMING PRE-FINISHED METAL FASCIA SPM TO GO UP AND OVER PARAPET SINGLE PLY MEMBRANE ROOFING SHEATHING - TYP. PRE-FINISHED METAL FASCIA 2X4 WOOD FRAMING COVER BOARD ROOF SHEATHING WOOD TRUSSES - SEE STRUCTURAL SHEATHING - TYP. PRE-FINISHED METAL SOFFIT WOOD TRUSSES - SEE STRUCTURAL A PRE-FINISHED METAL SOFFIT SHEATHING - SEE STRUCTURAL WOOD TRUSS AND BLOCKING - SEE STRUCTURAL R-21 INSULATION ROOF SHEATHING - SEE STRUCTURAL COVER BOARD FOR ROOFING MEMBRANE SINGLE PLY MEMBRANE ROOFING TERMINATION BAR AND SEALANT STEEL ANGLE - SEE STRUCTURAL SPM FLASHING - HEAT WELD TO MEMBRANE MASONRY VENEER WALL SHEATHING - TYP. B R01 1' - 2 " 1'-6" STANDING SEAM METAL ROOF PRE-FINISHED CURVED METAL RAKE TRIM ROOF SHEATHING - SEE STRUCTURAL PRE-FINISHED METAL FASCIA (2) LAYERS OF 3/4" SHAPED SHEATHING BARREL TRUSS - 55'-0" RADIUS T.O. TOP CORD - FILLED WITH INSULATION PRE-FINISHED METAL SOFFIT 2X WOOD BLOCKING MASONRY VENEER 1'-6" 1' - 2 " STANDING SEAM METAL ROOF ROOF SHEATHING - SEE STRUCTURAL PRE-FINISHED CURVED METAL RAKE TRIM 2X6 WOOD OUTLOOKER - SEE STRUCTURAL (2) LAYERS OF 3/4" SHAPED SHEATHING PRE-FINISHED METAL FASCIA 2X WOOD FRAMING PRE-FINISHED METAL SOFFIT MASONRY VENEER E 1'-8" PRE-FINISHED CURVED METAL RAKE TRIM ROOF SHEATHING - SEE STRUCTURAL STANDING SEAM METAL ROOF (2) LAYERS OF 3/4" SHAPED SHEATHING PRE-FINISHED METAL FASCIA BARREL TRUSS - 55'-0" RADIUS T.O. TOP CORD - FILLED WITH INSULATION PRE-FINISHED METAL SOFFIT 2X WOOD BLOCKING 1' - 2 " 1'-6 1/2" E 8" 4 1/2" 1' - 5 " 5/8" GYP. BOARD 2X6 WOOD FRAMING 1/2" WOOD SHEATHING STANDING SEAM METAL ROOF FLASHING 1/2" WOOD SHEATHING 5/8" GYP. BOARD WOOD FRAMING SCRIBED TO THE CURVE 2X WOOD FRAMING 1/2" WOOD SHEATHING 5/8" GYP. BOARD STEEL BEAM - SEE STRUCTURAL WOOD FRAMING SCRIBED TO THE CURVE 2 1/8" 3 3/8" 5 1 ' - 2 " 2'-1" PRE-FINISHED METAL DRIP EDGE PRE-FINISHED METAL FASCIA LSL RIM BOARD ROOF SHEATHING STANDING SEAM METAL ROOF SHAPED 2X WOOD OUTLOOKER - 5 1/2" MIN. DEPTH - FILLED WITH INSULATION 2X WOOD FRAMING PRE-FINISHED METAL SOFFIT 3'-9 1/2" STANDING SEAM METAL ROOF PRE-FINISHED CURVED METAL RAKE TRIM STEEL FASCIA BEAM - 20'-0" RADIUS T.O. BEAM - SEE STRUCTURAL (2) LAYERS 3/4" SHAPED SHEATHING PRE-FINISHED METAL FASCIA PRE-FINISHED METAL SOFFIT ROOF JOIST AND WOOD BLOCKING - FILLED INSULATION A 1' - 2 " STANDING SEAM METAL ROOF ROOF SHEATHING - SEE STRUCTURAL PRE-FINISHED METAL RAKE TRIM 2X6 WOOD OUTLOOKER - SEE STRUCTURAL LSL RIM BOARD PRE-FINISHED METAL FASCIA 2X WOOD FRAMING PRE-FINISHED METAL SOFFIT MASONRY VENEER 1'-6" 1'-11 1/4" B ROOF SHEATHING - SEE STRUCTURAL TERMINATION BAR AND SEALANT PRE-FINISHED METAL FLASHING MASONRY VENEER BARREL TRUSS - 55'-0" RADIUS T.O. TOP CORD - FILLED WITH INSULATION SHAPED 4X LEDGER - SEE STRUCTURAL STANDING SEAM METAL ROOF D PRE-FINISHED METAL DRIP EDGE PRE-FINISHED METAL FASCIA LSL RIM BOARD ROOF JOISTS - SEE STRUCTURAL PRE-FINISHED METAL SOFFIT MASONRY VENEER ROOF SHEATHING - SEE STRUCTURAL STANDING SEAM METAL ROOF 2X8 WOOD LEDGER ATTACHED TO STEEL BEAM - SEE STRUCTURAL 2X WOOD FRAMING R-13 INSULATION I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 5 : 0 7 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A7.2 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RO O F D E T A I L S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE: 1" = 1'-0" A7.2 A DETAIL SCALE: 1" = 1'-0" A7.2 B DETAIL SCALE: 1" = 1'-0" A7.2 H DETAIL SCALE: 1" = 1'-0" A7.2 C DETAIL SCALE: 1" = 1'-0" A7.2 D DETAIL SCALE: 1" = 1'-0" A7.2 E DETAIL SCALE: 1" = 1'-0" A7.2 F DETAIL SCALE: 1" = 1'-0" A7.2 J DETAIL SCALE: 1" = 1'-0" A7.2 G DETAIL SCALE: 1" = 1'-0" A7.2 K DETAIL SCALE: 1" = 1'-0" A7.2 L DETAIL SCALE: 1" = 1'-0" A7.2 M DETAIL SCALE: 1" = 1'-0" A7.2 N DETAIL SCALE: 1" = 1'-0" A7.2 P DETAIL SCALE: 1" = 1'-0" A7.2 Q DETAIL SCALE: 1" = 1'-0" A7.2 R DETAIL SCALE: 1" = 1'-0" A7.2 S DETAIL SCALE: 1" = 1'-0" A7.2 T DETAIL CAST IN PLACE CENTERLINE CENTERLINE OF BEAM CENTERLINE OF COLUMN CENTERLINE OF WALL CLEAR CONCRETE CONCRETE CONTROL JOINT CONCRETE SAWCUT JOINT CONCRETE MASONRY UNIT CONNECTION CONTINUOUS DEAD LOAD DOWN DRAWING(S) EQUAL EQUIPMENT EXPANSION JOINT EACH WAY FINISHED FLOOR FACE OF STEEL FACE OF WALL GAUGE GALVANIZED GENERAL STRUCTURAL NOTES CENTERLINE OF FOOTING FACE OF MEMBER EXPANSION BOLT EDGE OF SLAB DIAMETER GALV. GSN DN. DWG(S) EQ. EQUIP. EXP. JT (E.J.) E.W. F.F. F.O.S. F.O.W. GA. F.O.M. EXP. BOLT E.O.S. o OR DIA. C.I.P. C.L. C.L.B. C.L.C. C.L.W. CLR CONC C.C.J. C.S.J. C.M.U. CONN. CONT. D.L. C.L.F. W/ WITH W/O WITHOUT T.O.P. U.N.O. W.W.F. TYP. VERT T.O.S. T.O.W. T.O.D. T.O.F. T.O.L. T.O.M. STD T.O.B. T.L. SLH SLV SIM. SQ. PSF PSI REINF. PREFAB OPP. P.C. PLF N.T.S. O.C. O.F.W. TOP OF FOOTING UNLESS NOTED OTHERWISE WELDED WIRE FABRIC TOP OF MASONRY TOP OF PLATE TOP OF STEEL TOP OF WALL TYPICAL VERTICAL STANDARD TOP OF BEAM TOP OF DECK TOP OF LEDGER TOTAL LOAD OUTSIDE FACE OF WALL PRECAST CONCRETE POUNDS PER LINEAR FOOT POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH SHORT LEG VERTICAL SHORT LEG HORIZONTAL REINFORCING SIMILAR SQUARE NOT TO SCALE ON CENTER OPPOSITE PREFABRICATED AGGREGATE BASE COURSE AIR CONDITIONER ABOVE FINISHED FLOOR ALTERNATE ANCHOR BOLT AT (MEASUREMENT) BEAM BOTTOM OF BEAM BOTTOM OF DECK BEARING BELOW FINISHED FLOOR BOTTOM OF FOOTING A.B.C. A/C A.F.F. ALT. A.B. @ BM B.O.B. B.O.D. BRG B.F.F B.O.F. ABBREVIATIONS LBS (#) MFR('S) M.C.J. MECH'L. N/A LLV LLH HORIZ. K(KIP) GLB (GLULAM) I.F.W. L.L. LONG LEG VERTICAL MANUFACTURER('S) MASONRY CONTROL JOINT NOT APPLICABLE LONG LEG HORIZONTAL GLUED-LAMINATED BEAM INSIDE FACE OF WALL POUNDS MECHANICAL HORIZONTAL 1000 POUNDS LIVE LOAD EXISTING(E) MIN. MINIMUM MAX. MAXIMUM SYMBOLS LEGEND WALLS WITH SOLID LINES DESIGNATE STRUCTURAL (BEARING) WALLS. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. WALLS WITH HATCH DESIGNATE MASONRY WALLS. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. 5 6 7 , , - AS SHOWN ON PLAN INDICATES A SHEARWALL HOLDOWN. SEE HOLDOWN SCHEDULES AND DETAILS FOR ADDITIONAL INFORMATION. A B INDICATES HVAC EQUIPMENT ON ROOF OR IN ATTIC SPACE. SEE TYPICAL DETAILS FOR FRAMING INFORMATION. - AS SHOWN ON PLAN INDICATES A HELICAL PIER. XXXX CS16, CMSTC16, ECT. - AS SHOWN AT WALL OPENINGS INDICATE STRAPPING, PROVIDE STRAPPING PER "TYPICAL STRAP AT OPENING" DETAIL. D=xxx# INDICATES DRAG LOAD (ASD) THAT TRUSS MANUFACTURER IS TO DESIGN TRUSS FOR IN BOTH TENSION AND COMPRESSION. STEP INDICATES STEPPED OR DEPRESSED SLAB. C=X" INDICATES CAMBER IN BEAM. INDICATES RIDGID CONNECTION. (NOT ALL SYMBOLS NECESSARILY APPLY TO THIS PROJECT) P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. SC1, SC2, ETC. - AS SHOWN ON PLAN INDICATES A STEEL COLUMN. SEE STEEL COLUMN SCHEDULE FOR ADDITIONAL INFORMATION. COLUMNS START AT THE LEVEL THEY ARE CALLED OUT ON. PX SCX RME XXX# N O TF O R C O N S T R U C T I O N P U R P O S E S PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : DBP 4/ 5 / 2 0 2 3 9 : 2 5 : 3 0 A M A u t o d e s k D o c s : / / 2 3 - 0 3 8 _ B e e h i v e F ed e r a l C r e d i t U n i o n R e x b u r g / I F 2 3 - 0 3 8 _ B e e h i v e F e d e r a l C r e d i t U n i o n R e x b u r g . r v t S1.0 23-038 BE E H I V E F C U -N O R T H R E X B U R G GE N E R A L S T R U C T U R A L N O T E S 02/23/2023 AV SHEET INDEX SHEET DESCRIPTION DETAILS S1.0 GENERAL STRUCTURAL NOTES --- S1.1 SPECIAL INSPECTIONS --- S1.2 TYPICAL DETAILS T - SERIES S1.3 TYPICAL DETAILS T - SERIES S2.0 FOUNDATION PLAN --- S2.1 LOWER ROOF FRAMING PLAN --- S2.2 UPPER ROOF FRAMING PLAN --- S3.0 FOUNDATION DETAILS 100 - SERIES S3.1 FOUNDATION DETAILS 100 - SERIES S4.0 ROOF FRAMING DETAILS 200 - SERIES S4.1 ROOF FRAMING DETAILS 200 - SERIES S4.2 ROOF FRAMING DETAILS 200 - SERIES S4.3 ROOF FRAMING DETAILS 200 - SERIES LOCATION LIVE / SNOW LOAD DEAD LOAD ELEMENTS LIVE LOAD TOTAL LOAD LOCATION:MINIMUM COVER TOLERANCE USE:CONCRETE STRENGTH: MAX W/C RATIO AIR ENTRAINMENT USE:MATERIAL: GENERAL REQUIREMENTS: BASIS FOR DESIGN: FOUNDATION NOTES:CONCRETE:WOOD:DEFERRED SUBMITTAL ITEMS: 1.THE STRUCTURAL SYSTEMS AND MEMBERS DEPICTED HEREIN HAVE BEEN DESIGNED PRIMARILY TO SAFEGUARD AGAINST MAJOR STRUCTURAL DAMAGE AND LOSS OF LIFE, NOT TO LIMIT DAMAGE OR MAINTAIN FUNCTION (IBC SECTION 101.3). 2.THESE DRAWINGS, AND THEIR ASSOCIATED STRUCTURAL CALCULATIONS, HAVE BEEN PERFORMED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE STRUCTURAL ENGINEER'S IN THIS OR SIMILAR LOCALITIES. THEY NECESSARILY ASSUME THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKMEN WHO HAVE A WORKING KNOWLEDGE OF THE INTERNATIONAL BUILDING CODE CONVENTIONAL FRAMING REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR FRAMING ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, IT IS UNDERSTOOD THAT THE CONTRACTOR WILL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR ALL MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3.THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION SUCH THAT DESIGN LIVE LOAD PER SQUARE FOOT AS STATED HEREIN IS NOT EXCEEDED. OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF AN OPTION IS USED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES, AND SHALL COORDINATE ALL DETAILS. 4.WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. TYPICAL DETAILS AND NOTES ARE NOT NECESSARILY INDICATED ON THE PLANS, BUT SHALL APPLY NONE-THE-LESS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. DETAILS MAY SHOW ONLY ONE SIDE OF CONNECTION OR MAY OMIT INFORMATION FOR CLARITY. 5.ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ARCHITECT AND STRUCTURAL ENGINEER. 6.ANY INSPECTIONS, SPECIAL (IBC CHAPTER 17) OR OTHERWISE THAT ARE REQUIRED BY THE BUILDING CODES, LOCAL BUILDING DEPARTMENTS, OR BY THESE PLANS SHALL BE DONE BY AN INDEPENDENT INSPECTION COMPANY OR THE BUILDING DEPARTMENT, SITE VISITS BY THE STRUCTURAL ENGINEER DO NOT CONSTITUTE AN OFFICIAL INSPECTION, UNLESS SPECIFICALLY CONTRACTED FOR. 1.BUILDING CODE: 2018 EDITION OF THE IBC WITH CITY/COUNTY AMENDMENTS. RISK CATEGORY = II 4. SEISMIC DESIGN PARAMETERS: ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE IMPORTANCE FACTOR Ie = 1.00 SEISMIC DESIGN CATEGORY D MAPPED SPECTRAL RESPONSE ACCELERATIONS S1 = 0.143, SS = 0.367 DESIGN SPECTRAL RESPONSE ACCELERATIONS PERCENT SNOW INCLUDED WITH SEISMIC LOADS 20 VERTICAL SHEAR TRANSFER ELEMENTS: AT BUILDING: PLYWOOD SHEARWALL(S) AT DRIVE-THRU: STEEL ORDINARY CANTILEVERED COLUMNS R = 6.5, CS = 0.057 5. WIND DESIGN PARAMETERS (STRENGTH): ULTIMATE WIND SPEED 115 MPH (3 SECOND GUST) WIND EXPOSURE C IMPORTANCE FACTOR Iw = 1.00 INTERNAL PRESSURE COEFFICIENT -0.18 COMPONENT AND CLADDING PRESSURE 27.2 PSF NET UPLIFT ON ROOF 26.5 PSF 2. VERTICAL LOADS: ROOF ROOF = 35 PSF GROUND = 50 PSF 20 PSF 3. DEFLECTION LIMITS: ROOF TRUSSES/JOISTS L/360 L/240 BEAMS L/360 L/240 3.A ONE-THIRD INCREASE IN BEARING PRESSURES IS ALLOWED WITH SEISMIC OR WIND LOAD COMBINATIONS. LATERAL BEARING AND LATERAL SLIDING RESISTANCE MAY BE COMBINED. 4.ALL FOUNDATIONS SHALL BEAR ON COMPACTED ENGINEERED FILL OR COMPETENT NATIVE SOIL SUBBASE COMPACTED TO 95% DRY DENSITY (STANDARD PROCTOR). GRADE IS DEFINED AS LOWEST ADJACENT GRADE WITHIN 5 FEET OF THE BUILDING FOR PERIMETER FOOTINGS. WHERE EXTERIOR PAVING OR CONCRETE IS DIRECTLY ADJACENT TO BUILDING, GRADE IS DEFINED AS TOP OF EXTERIOR PAVING AT LEAST 5 FEET FROM BUILDING. CONCRETE FOOTING EXCAVATIONS SHALL BE CLEAN AND FREE OF LOOSE DEBRIS OR UN-COMPACTED MATERIAL AT TIME OF CONCRETE PLACEMENT. 5.CONCRETE SLABS ON GRADE SHALL BE SUPPORTED ON A 4 INCH (MIN) LAYER OF FREE-DRAINING GRANULAR MAT (DRAINAGE FILL COURSE). THE MAT SHOULD CONSIST OF A WELL GRADED SAND AND GRAVEL MIXTURE WITH MAXIMUM 3/4-INCH CRUSHED AGGREGATE. THE GRANULAR MAT SHOULD BE COMPACTED TO NO LESS THAN 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D1557. 6.BACKFILL AGAINST RESTRAINED WALLS SHALL NOT BE PLACED UNTIL AFTER THE WALLS ARE SUPPORTED BY THE COMPLETION OF INTERIOR FLOOR SYSTEMS AND CONCRETE OR GROUT STRENGTH HAS REACHED THE 28 DAY STRENGTH LISTED BELOW. THE SOIL DESIGN VALUES FOR THE FOUNDATION ARE: ALLOWABLE BEARING PRESSURE 2500 PSF ALLOWABLE LATERAL BEARING PRESSURE 100 PSF/FT ALLOWABLE LATERAL SLIDING COEFFICIENT 0.25 FOUNDATION BEARING DEPTH 36" BELOW FINISHED GRADE 2.ALL NORMAL WEIGHT CONCRETE SHALL BE REGULAR WEIGHT OF 150 POUNDS PER CUBIC FOOT USING HARD ROCK AGGREGATES. AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. . 3.LAP SPLICES FOR BEAMS AND FLOOR SLABS SLABS SHALL BE ACCORDING TO CHAPTER 12 OF ACI 318 OR LAP SCHEDULE ON THESE DRAWINGS. STAGGER SPLICES A MINIMUM OF ONE LAP LENGTH. NO TACK WELDING OF REINFORCING BARS ALLOWED WITHOUT PRIOR REVIEW OF PROCEDURE WITH THE STRUCTURAL ENGINEER. LATEST ACI CODE AND DETAILING MANUAL APPLY. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. VERTICAL WALL BARS SHALL BE SPLICED AT OR NEAR FLOOR LINES. 4.ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING STEEL NOT NOTED AS "CLEAR" OR "CLR" ARE TO CENTER OF STEEL. MINIMUM COVER FOR NON-PRESTRESSED CONCRETE REINFORCING SHALL BE AS FOLLOWS: 5.MAXIMUM SLUMP FOR ALL CONCRETE SHALL BE 6". PORTLAND CEMENT SHALL CONFORM TO ASTM C150. TYPE V CEMENT SHALL BE USED FOR CONCRETE IN CONTACT WITH ALKALINE SOIL, AND TYPE II ELSEWHERE. 6.NO MORE THAN 90 MINUTES SHALL ELAPSE BETWEEN CONCRETE BATCHING AND CONCRETE PLACEMENT UNLESS APPROVED BY THE TESTING AGENCY. 7.CONCRETE PLACEMENT AND QUALITY SHALL BE PER RECOMMENDATIONS IN ACI 614, ACI 301 AND ACI 318. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS ON GRADE NEED BE VIBRATED ONLY AROUND AND UNDER FLOOR DUCTS, ETC. CAST CLOSURE POUR, WHERE SHOWN ON PLANS AROUND COLUMNS AFTER COLUMN DEAD LOAD IS APPLIED. REMOVE ALL DEBRIS FROM FORMS BEFORE PLACING CONCRETE. ALL ITEMS TO BE CAST IN CONCRETE SUCH AS REINFORCING, DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY POSITIONED IN THE FORMS BEFORE PLACING THE CONCRETE. 8.ALL CONCRETE SLABS ON GRADE SHALL BE DIVIDED INTO AREAS BY CONTROL JOINTS (KEYED OR SAW CUT) SUCH THAT ONE SLAB AREA DOES NOT EXCEED A MAXIMUM LENGTH OF 24 TIMES THE SLAB THICKNESS IN BOTH DIRECTIONS (EXAMPLE: 4" SLAB = 8'-0" LENGTH). SQUARE LAYOUTS ARE PREFERRED, BUT THE SLAB GEOMETRY MAY DICTATE OTHERWISE. THE RATIO OF THE LONG TO SHORT DISTANCE SHALL NOT EXCEED 1.3. IT IS RECOMMENDED THAT SAW CUTS BE MADE WITHIN 16 HOURS OF CONCRETE BATCHING. KEYED CONTROL JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING POURING, ALL OTHER JOINTS MAY BE SAW CUT. 9.HORIZONTAL PIPES AND ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE AND SLABS ON GRADE EXCEPT WHERE SPECIFICALLY APPROVED OR NOTED BY THE STRUCTURAL ENGINEER. PIPES AND CONDUITS SHALL NOT IMPAIR THE STRENGTH OF THE WORK. 10. FLY ASH MAY BE USED ONLY IF PERMITTED BY ARCHITECTURAL SPECIFICATIONS AND SHALL BE LIMITED TO 18 PERCENT OF CEMENTITIOUS MATERIALS AND SHALL HAVE A REPLACEMENT FACTOR OF 1.2 RELATIVE TO CEMENT REPLACED. NO FLY ASH ADDITIVES SHALL BE USED IN FLATWORK OR ARCHITECTURALLY EXPOSED CONCRETE. 11.COLD/HOT WEATHER CONCRETE CONSTRUCTION: PROTECT CONCRETE FROM DAMAGE OR REDUCED STRENGTH IN COMPLIANCE WITH ACI 305 AND 306. 12.CONCRETE MIXES SHALL BE DESIGNED BY A CERTIFIED LABORATORY AND APPROVED BY THE STRUCTURAL ENGINEER. 13.LIMIT ALKALI-SILICA REACTION (ASR) TO 0.1% EXPANSION AT 28 DAYS IN CONCRETE MIX AT ALL EXTERIOR CONCRETE AND INTERIOR CONCRETE EXPOSED TO MOISTURE. CAST AGAINST EARTH (FOOTINGS)3"± 3/8" SLABS ON GRADE 1 1/2" EXPOSED TO EARTH OR WEATHER - #5 AND SMALLER EXPOSED TO EARTH OR WEATHER - #6 AND LARGER 2" NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND ROOF SLAB 1" STRUCTURAL SLABS AND WALLS BEAMS AND COLUMNS (PRIMARY) REINFORCEMENT, TIES, STIRRUPS AND SPIRALS 1. MINIMUM 28 DAY CONCRETE STRENGTH SHALL BE AS FOLLOWS: FOOTINGS 3500 PSI 0.50 5.5% ± 1% FOUNDATION WALLS 4500 PSI 0.45 5.5% ± 1% INTERIOR CONCRETE SLABS ON GRADE 3500 PSI 0.45 N/A 1.GENERAL: DO NOT NOTCH OR DRILL JOISTS, BEAMS, OR LOAD BEARING STUDS WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER THROUGH THE ARCHITECT. DOUBLE UP JOISTS AND BLOCKING UNDER PARTITIONS. PROVIDE 2" (NOMINAL) SOLID BLOCKING AT SUPPORTS OF ALL JOISTS. UNLESS NOTED OTHERWISE ON PLANS/DETAILS PROVIDE 2x SOLID BLOCKING AT MID-HEIGHT OF BEARING STUD WALLS. ALL NAILING NOT NOTED SHALL BE ACCORDING TO IBC TABLE 2304.10.1. JOIST HANGERS AND OTHER MISC. FRAMING ANCHORS SHALL BE SIMPSON STRONG-TIE COMPANY, INC. OR OTHER MANUFACTURER WITH CURRENT ICC-ES APPROVAL. 2.SAWN LUMBER: FRAMING LUMBER SHALL COMPLY WITH THE LATEST EDITION OF THE GRADING RULES OF THE WESTERN WOOD PRODUCTS ASSOCIATION (WWPA) OR THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB). ALL SAWN LUMBER SHALL BE STAMPED WITH THE GRADE MARK OF AN APPROVED LUMBER GRADING AGENCY. SAWN LUMBER SHALL HAVE THE FOLLOWING MINIMUM GRADE UNLESS NOTED OTHERWISE IN SCHEDULES: 2x4 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) 2x6 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) JOISTS, TOP PLATES AND ALL OTHER SAWN LUMBER DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) BEAMS AND POSTS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) LOCATION:NOMINAL THICKNESS: SPAN INDEX RATING: EDGE ATTACHMENT: FIELD ATTACHMENT: WALL 8d AT 6" O.C. 8d AT 12" O.C. ROOF 8d AT 6" O.C. 8d AT 12" O.C. ROOF 8d AT 6" O.C. 8d AT 12" O.C. ROOF 10d AT 6" O.C.10d AT 12" O.C. ROOF 10d AT 6" O.C. 10d AT 12" O.C. ROOF 10d AT 6" O.C. 10d AT 12" O.C. FLOOR 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. 3. PLYWOOD: ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING CONFORMING TO STANDARD PS 1-95. LAY UP PLYWOOD WITH FACE GRAIN IN PERPENDICULAR TO SUPPORTS (ON ROOFS WHERE PLYWOOD IS LAID UP WITH FACE GRAIN PARALLEL TO SUPPORTS, USE A MINIMUM OF 5-PLY PLYWOOD, STAGGER JOINTS). ALL NAILING, COMMON NAILS. BLOCKING AT PANEL EDGES WHERE INDICATED ON PLANS. ALL PLYWOOD SHALL BE OF THE FOLLOWING NOMINAL THICKNESS, SPAN/INDEX RATING AND SHALL BE NAILED AS FOLLOWS UNLESS NOTED OTHERWISE ON THE PLANS: SCREWS AT FLOOR SHEATHING SHALL BE #8 SCREWS AND SHALL PENETRATE AT LEAST 1 1/2" INTO THE SUPPORTING MEMBER. ALL FLOOR SHEATHING SHALL BE GLUED TO SUPPORTING MEMBERS WITH AN APA AFG-01 QUALIFIED ADHESIVE. PLYWOOD ALTERNATE: AMERICAN PLYWOOD ASSOCIATION PERFORMANCE RATED SHEATHING MAY BE USED AS AN ALTERNATE TO PLYWOOD WITH PRIOR APPROVAL OF OWNER, ARCHITECT AND ROOFER. IT MAY NOT BEUSED ON ROOFS WHERE BUILT UP ROOF SYSTEM IS TO BE GUARANTEED BY ROOFER. RATED SHEATHING SHALL COMPLY WITH CURRENT ICC-ES REPORTS AND SHALL HAVE A SPAN RATING EQUIVALENT TO OR BETTER THAN THE PLYWOOD IT REPLACES. ATTACHMENT AND THICKNESS (WITHIN 1/32") SHALL BE THE SAME AS THE PLYWOOD IT REPLACES. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 4.NOMINAL 2x AND 3x DECKING. TONGUE AND GROOVE TYPE. MINIMUM Fb = 1,600 PSI, MINIMUM E = 1,300,000 PSI. INSTALL WITH TONGUES UP SLOPE ON PITCHED ROOFS, AND OUTWARD IN THE DIRECTION OF LAYING ON FLAT ROOFS. NAIL EACH PLANK WITH 16d TOENAIL (THRU THE TONGUE) AND 16d FACE NAIL AT EACH SUPPORT. DECK SHALL BE INSTALLED AS SIMPLE SPAN WITH ALL PLANKS BEARING ON TWO SUPPORTS. FOR REFERENCE AND/OR ADDITIONAL INFORMATION SEE AITC 117-2010. 5.GLUED-LAMINATED BEAMS (GLB): GLUED-LAMINATED BEAMS SHALL BE DOUGLAS FIR COMBINATION AT 24F-V4 AT SIMPLE SPAN BEAMS AND 24F-V8 AT MULTI-SPAN AND CANTILEVERED BEAMS WITH THE FOLLOWING MINIMUM PROPERTIES: FB = 2,400 PSI, FV = 190 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,800 KSI. ALL BEAMS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. BEAMS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. CAMBER AS SHOWN ON DRAWINGS. STANDARD CAMBER IS BASED ON A RADIUS OF CURVATURE OF 2000 FEET. 6.GLUED-LAMINATED COLUMNS: GLUED-LAMINATED COLUMNS SHALL BE DOUGLAS FIR COMBINATION 3 WITH THE FOLLOWING MINIMUM PROPERTIES: FBY = 2,100 PSI, FBX = 2000 PSI, FVY = 230 PSI, FVX = 265 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,900 KSI. ALL COLUMNS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. COLUMNS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. 7.LAMINATED VENEER LUMBER (LVL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LVLs SHALL BE: FB = 2,600 PSI, FV = 285 PSI, E = 2,000 KSI. 8.PARALLEL STRAND LUMBER (PSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR PSLs SHALL BE: FB = 2,900 PSI, FV = 290 PSI, E = 2,000 KSI. 9.LAMINATED STRAND LUMBER (LSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LSLs SHALL BE: FB = 2,325 PSI, FV = 310 PSI, E = 1,550 KSI. 10.SILL PLATES RESTING ON CONCRETE OR MASONRY SHALL BE OF TREATED FIR. SHEAR WALLS AND EXTERIOR WALL SILLS AT CONCRETE SLAB SHALL HAVE A MINIMUM OF (2) ANCHOR BOLTS PER PIECE. PROVIDE ANCHOR BOLT AT 9" MAXIMUM, 4" MINIMUM FROM THE END OF EACH PIECE AT SPLICE OR END OF WALL. MAXIMUM ANCHOR BOLT SPACING SHALL BE 72" ON CENTER UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. ALL ANCHOR BOLTS (OTHER THAN BOLTS FOR HOLDOWNS) SHALL EMBED 7" INTO CONCRETE. ANCHOR BOLTS FOR HOLDOWNS SHALL NOT BE CONSIDERED AS PART OF REQUIRED ANCHOR BOLTS ON SHEAR WALLS. ALL EXTERIOR WALLS SHALL BE SECURED WITH MINIMUM ANCHOR BOLTS. INTERIOR WALLS MAY BE SECURED TO CONCRETE WITH EITHER ANCHOR BOLTS OR POWER DRIVEN SHOT PINS UNLESS NOTED OTHERWISE ON PLANS. 11.BOLTING: ALL BOLTS IN WOOD CONNECTIONS SHALL CONFORM TO ASTM A307. BOLTS SHALL BE INSTALLED IN HOLES BORED WITH A BIT 1/16" LARGER THAN THE Ø (DIAMETER) OF THE BOLT. BOLTS AND NUTS SEATING ON WOOD SHALL HAVE CUT STEEL WASHERS UNDER HEADS AND NUTS. NICK THREADS TO PREVENT LOOSENING. 12. OPEN-WEB WOOD ROOF TRUSSES SD1 = 0.221, SDS = 0.369 GENERAL STRUCTURAL NOTES (APPLY UNLESS NOTED OTHERWISE ON PLANS/DETAILS) ± 1/4" 1 1/2" ± 3/8" ± 3/8" 1/8" 3/4"1/8" 1 1/2" 3/8" PREFABRICATED WOOD TRUSSES: PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED TO SUPPORT SELF WEIGHT PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS. WHERE UNINHABITABLE ATTIC SPACE CAN BE USED FOR STORAGE, A 20 PSF LIVE LOAD ON THE BOTTOM CHORD SHALL BE INCLUDED IN THE ANALYSIS. BRIDGING SIZE AND SPACING BY TRUSS MANUFACTURER UNLESS NOTED OTHERWISE. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED ENGINEER FOR REVIEW PRIOR TO MANUFACTURE FOR BOTH ROOF AND FLOOR TRUSSES WHEN USED. SHOP DRAWINGS SHALL SHOW ANY SPECIAL DETAILS REQUIRED AT BEARING POINTS. ALL CONNECTORS SHALL HAVE CURRENT ICC-ES APPROVAL. ADDITIONAL TRUSSES SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. PER IBC SECTION 2303.4 AND TPI-1: EACH TRUSS SHALL BE LEGIBLY BRANDED, MARKED OR OTHERWISE HAVE PERMANENTLY AFFIXED THERETO THE IDENTITY OF THE COMPANY MANUFACTURING THE TRUSS, THE DESIGN LOADS, AND THE TRUSS SPACING - WITHIN TWO FEET OF THE CENTER OF THE SPAN ON THE FACE OF THE BOTTOM CHORD. PREFABRICATED WOOD/STEEL WEB JOIST/PURLINS (TJI/TJL SERIES OR EQUAL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST EDITION ICC-ES REPORT. CONNECTIONS AND BEARING MATERIAL TO BE DESIGNED AND FURNISHED BY JOIST FABRICATOR. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED STRUCTURAL ENGINEER FOR REVIEW PRIOR TO MANUFACTURE. ADDITIONAL JOISTS SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. 7/16" OR 1/2" 7/16" OR 1/2" 15/32" OR 1/2" 19/32" OR 5/8" 23/32" OR 3/4" 7/8" 3/4" T&G 7/8" T&G 1 1/8" T&G 24/16 24/16 32/16 40/20 48/24 60/32 48/24 60/32 60/48 1. 2.SITE PREPARATION AND GRADING REQUIREMENTS OF THE SOIL REPORT AND ANY ADDENDUM'S SHALL BE COMPLETED PRIOR TO CONSTRUCTION OF FOUNDATIONS. ANY TESTS OR INSPECTIONS REQUIRED BY THE SOIL REPORT SHALL BE PERFORMED PRIOR TO PLACEMENT OF FOUNDATION REINFORCING STEEL OR CONCRETE. ALTERATIONS TO SITE PREPARATION OR GRADING SHALL BE REPORTED TO THE GEOTECHNICAL ENGINEER PRIOR TO FOUNDATION CONSTRUCTION. FOUNDATIONS DESIGNED IN CONFORMANCE WITH RECOMMENDATIONS BY: XCELL ENGINEERING, LLC. REPORT NO. P22296 DATED DECEMBER 14, 2022. REINFORCING STEEL: 1.ASTM A615 GRADE 60 (FY = 60 KSI) DEFORMED BARS FOR ALL BARS #4 AND LARGER. ASTM A615 GRADE 40 (FY = 40 KSI) DEFORMED BARS FOR ALL BARS #3 AND SMALLER. GRADE 60 DEFORMED BARS SHALL BE USED FOR CONCRETE WALLS, BEAMS, AND ELEVATED SLAB REINFORCING. 2.WELDING OF REINFORCING BARS SHALL BE MADE ONLY TO ASTM A706 GRADE 60 BARS AND ONLY USING E90 SERIES RODS. WELDING OF REINFORCING BARS SHALL BE MADE ONLY AT LOCATIONS SHOWN ON PLANS OR DETAILS. 3.REINFORCING BAR SPACING GIVEN ARE MAXIMUM ON CENTERS. ALL BARS PER CRSI SPECIFICATIONS AND HANDBOOK. DOWEL ALL VERTICAL REINFORCING TO FOUNDATION. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. STEEL: 1. MATERIALS: ROLLED W SHAPES, SHALL CONFORM TO ASTM A992 (FY=50 KSI). ALL OTHER STRUCTURAL STEEL SHAPES, ROLLED SECTIONS, BARS AND PLATES SHALL CONFORM TO ASTM A36 (FY = 36 KSI). ALL PIPE STEEL SHALL BE ASTM A501 (FY = 36 KSI) OR ASTM A53, TYPE E OR S, GRADE B (FY = 35 KSI). ALL TUBULAR STEEL SHALL BE ASTM A500 (FY = 46 KSI). 2.ALL BOLTS AND STUDS SHALL BE ASTM A307, UNLESS NOTED OTHERWISE. ALL EXPANSION BOLTS TO HAVE CURRENT ICC REPORT RATING FOR MATERIAL INTO WHICH INSTALLATION TAKES PLACE. HEADED STUDS SHALL CONFORM TO ALL REQUIREMENTS OF THE LATEST EDITION OF THE "RECOMMENDED PRACTICES FOR STUD WELDING" AND THE "STRUCTURAL WELDING CODE" PUBLISHED BY AWS. ALL BOLTS, ANCHOR BOLTS, EXPANSION BOLTS, ETC. SHALL BE INSTALLED WITH STEEL WASHERS AT FACE OF WOOD OR AT SLOTTED HOLES IN STEEL SECTIONS. 3. ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH AISC SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, LATEST EDITION. 4.WELDING SHALL BE BY WELDERS HOLDING VALID CERTIFICATES AND HAVING CURRENT EXPERIENCE IN THE TYPE OF WELD SHOWN ON THE DRAWINGS OR NOTES. ALL WELDING SHALL USE E70 SERIES LOW HYDROGEN RODS UNLESS NOTED OTHERWISE. ALL WELDING PER LATEST AMERICAN WELDING SOCIETY STANDARDS. ALL WELDS ON DRAWINGS ARE SHOWN AS SHOP WELDS. CONTRACTOR MAY SHOP WELD OR FIELD WELD AT HIS DISCRETION. ALL FULL PENETRATION WELDS SHALL BE TESTED AND CERTIFIED BY AN INDEPENDENT TESTING LABORATORY. 5.STEEL TO STEEL BOLTED CONNECTIONS: HIGH STRENGTH BOLTS SHALL BE ASTM A325N AND SHALL BE INSTALLED AS BEARING-TYPE CONNECTIONS WITH THREADS INCLUDED IN SHEAR PLANE (TYPE "N" CONNECTION UNLESS NOTED OTHERWISE). BOLTS MAY BE TIGHTENED USING ANY AISC APPROVED METHOD. 6. DRYPACK SHALL BE 5,000 PSI FIVE STAR NON-SHRINK GROUT OR EQUIVALENT. INSTALL DRYPACK UNDER BEARING PLATES BEFORE FRAMING MEMBER IS INSTALLED. AT COLUMNS, INSTALL DRYPACK UNDER BASE PLATES AFTER COLUMN HAS BEEN PLUMBED BUT PRIOR TO FLOOR OR ROOF INSTALLATION. 7.SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS IN ADDITION TO ITEMS REQUIRED BY ARCHITECTURAL SPECIFICATIONS, THE CONTRACTOR SHALL REVIEW ALL SHOP DRAWINGS PRIOR TO SUBMITTAL. ITEMS NOT IN ACCORDANCE WITH CONTRACT DRAWINGS SHALL BE FLAGGED UPON HIS REVIEW. VERIFY ALL DIMENSIONS WITH ARCHITECT. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM ORIGINAL CONTRACT DRAWINGS SHALL BE CLOUDED. ANY OF THE AFOREMENTIONED WHICH ARE NOT CLOUDED OR FLAGGED BY SUBMITTING PARTIES, SHALL NOT BE CONSIDERED APPROVED AFTER THE STRUCTURAL ENGINEER'S REVIEW, UNLESS NOTED ACCORDINGLY. ANY ENGINEERING PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW, SHALL BEAR THE SEAL OF A STRUCTURAL ENGINEER REGISTERED IN THE APPROPRIATE STATE. THE SHOP DRAWINGS DO NOT REPLACE THE ORIGINAL CONTRACT DRAWINGS. ITEMS OMITTED OR SHOWN INCORRECTLY AND ARE NOT FLAGGED BY THE STRUCTURAL ENGINEER ARE NOT TO BE CONSIDERED CHANGES TO ORIGINAL DRAWINGS. THE ADEQUACY OF ENGINEERING DESIGNS AND LAYOUT PERFORMED BY THE OTHERS RESTS WITH THE DESIGNING OR SUBMITTING AUTHORITY. REVIEWING IS INTENDED ONLY AS AN AID TO THE CONTRACTOR IN OBTAINING CORRECT SHOP DRAWINGS. RESPONSIBILITY FOR CORRECTNESS SHALL REST WITH THE CONTRACTOR. ALLOW (5) WORKING DAYS FOR THE STRUCTURAL ENGINEER'S REVIEW. ONE COPY OF EACH SUBMITTAL WILL BE RETAINED FOR THE STRUCTURAL ENGINEER'S RECORDS. BRICK VENEER ANCHORAGE: BRICK VENEER ANCHOR CLIPS, ANCHORS, AND ATTACHEMENTS SHALL BE HOT-DIPPED GALVANIZED AND EITHER OF THE FOLLOWING FROM HOHMANN & BARNARD, INC. OR APPROVED EQUAL: 1.DW-10HS W/ S.I.S. (SEISMICLIP INTERLOCKING SYSTEM) SEISMIC VENEER ANCHORS 2.345-BT W/ S.I.S. (SEISMICLIP INTERLOCKING SYSTEM) SEISMIC VENEER ANCHORS INSTALLATION: 3.CLIPS SHALL BE ATTACHED AT 24" O.C. HORIZONTAL AND 16" O.C. VERTICAL (MAX) USING #10 HOT-DIPPED GALVANIZED SCREWS. 4. WHERE WOOD BACKUP IS USED, PROVIDE SHEATHING AND WATERPROOFING AS REQUIRED. 5.PROVIDE CONTINUOUS HOT-DIPPED GALVANIZED WIRE (9-GAUGE OR 3/16"Ø) ATTACHED TO EACH CLIP. R = 1.25, CS = 0.295 fax: 208.227.8405 1020 E. Lincoln Road Structural Engineering Idaho Falls, ID 83401 phone: 208.227.8404 info@frost-structural.com FROST S tampe d Engine e re d roof tru sse s approv e d b y B u ilding D e sign P rofe ssional ne e de d whe n re ce iv e d. N O TF O R C O N S T R U C T I O N P U R P O S E S PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : DBP 4/ 5 / 2 0 2 3 9 : 2 5 : 3 0 A M A u t o d e s k D o c s : / / 2 3 - 0 3 8 _ B e e h i v e F ed e r a l C r e d i t U n i o n R e x b u r g / I F 2 3 - 0 3 8 _ B e e h i v e F e d e r a l C r e d i t U n i o n R e x b u r g . r v t S1.1 23-038 BE E H I V E F C U -N O R T H R E X B U R G SP E C I A L I N S P E C T I O N S 02/23/2023 AV VERIFICATION AND INSPECTION OF STRUCTURAL STEEL VERIFICATION AND INSPECTION OB S E R V E PE R F O R M 1. INSPECTION TASKS PRIOR TO WELDING (TABLE N5.4-1) A. WELDER QUALIFICTION RECORDS AND CONTINUITY RECORDS X B. WELDING PROCEDURE SPECIFICATIONS (WPS) AVAILABLE X C. MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE X D. MATERIAL IDENTIFICATION (TYPE/GRADE)X E. WELDER IDENTIFICATIONS SYSTEM (THE FABRICATOR OR ERECTOR, AS APPLICABLE, SHALL MAINTAIN A SYSTEM BY WHICH A WELDER WHO HAS WELDED A JOINT OR MEMBER CAN BE IDENTIFIED. (STAMPS, IF USED, SHALL BE THE LOW STRESS TYPE) X F. FIT-UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY), JOINT PREPARATION, DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL), CLEANLINESS (CONDITION OF STEEL SURFACES), TACKING (TACK WELD QUALITY AND LOCATION) , BACKING TYPE AND FIT (IF APPLICABLE) X G. FIT-UP OF CJP GROOVE WELDS OF HSS T-, Y- AND K-JOINTS WITHOUT BACKING (INCLUDING JOINT GEOMETRY), JOINT PREPARATIONS, DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL), CLEANLINESS (CONDITION OF STEEL SURFACES), TACKING (TACK WELD QUALITY AND LOCATION X H. CONFIGURATION AND FINISH OF ACCESS HOLES X I. FIT-UP OF FILLET WELDS, DIMENSIONS (ALIGNMENT, GAPS AT ROOT), CLEANLINESS (CONDITION OF STEEL SURFACES) TACKING (TACK WELD QUALITY AND LOCATION) X J. CHECK WELDING EQUIPMENT - - 2. INSPECTION TASKS DURING WELDING (TABLE N5.4-2) A. CONTROL AND HANDLING OF WELDING CONSUMABLES, PACKAGING, EXPOSURE CONTROL X B. NO WELDING OVER CRACKED TACK WELDS X C. ENVIRONMENTAL CONDITIONS, WIND SPEED WITHIN LIMITS, PRECIPITATION AND TEMPERATURE X D. WELDING PROCEDURE SPECIFICATIONS (WPS) FOLLOWED, SETTINGHS ON WELDING EQUIPMENT, TRAVEL SPEED, SELECTED WELDING MATERIALS, SHIELDING GAS TYPE/FLOW RATE, PREHEAT APPLIED, INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.), PROPER POSITION (F, V, H, OH) X E. WELDING TECHNIQUES, INTERPASS AND FINAL CLEANING, EACH PASS WITHIN PROFILE LIMITATIONS, EACH PASS MEETS QUALITY REQUIREMENTS X F. PLACEMENT AND INSTALLATION OF STEEL HEADED STUD ANCHORS X 3. INSPECTION TASKS AFTER WELDING (TABLE N5.4-3) A. WELDS CLEANED X B. SIZE LENGTH AND LOCATION OF WELDS X C. WELDS MEET VISUAL ACCEPTANCE CRITERIA, CRACK PROHIBITION, WELD/BASE-METAL FUSION, CRATER CROSS SECTION, WELD PROFILES, WELD SIZE, UNDERCUT, POROSITY X D. ARC STRIKES X E. K-AREA (WHEN WELDING OF DOUBLER PLATES, CONTINUITY PLATES OR STIFFENERS HAS BEEN, ERFORMED IN THE K-AREA, VISUALLY INSPECT THE WEB K-AREA FOR CRACKS WITHIN 3 IN. (75 MM) OF THE WELD). X F. WELD ACCESS HOLES IN ROLLED HEAVY SHAPES AND BUILT-UP HEAVY SHAPES (AFTER ROLLED HEAVY SHAPES AND BUILT-UP HEAVY SHAPES ARE WELDED, VISUALLY INSPECT THE WELD ACCESS HOLE FOR CRACKS) X G. BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED) X H. REPAIR ACTIVITIES X I. DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER X J. NO PROHIBITED WLEDS HAVE BEEN ADDED WITHOUT THE APPROVAL OF THE EOR X 4. INSPECTION TASKS PRIOR TO BOLTING (TABLE N5.6-1) A. MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENER MATERIALS X B. FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS X C. CORRECT FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE, BOLT LENGTH IF THREADS ARE TO BE EXCLUDED FROM SHEAR PLANE)X D. CORRECT BOLTING PROCEDURE SELECTED FOR JOINT DETAIL X E. CONNECTION ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACE CONDITION AND HOLE PREPARATION, IF SPECIFIED, MEET APPLICABLE REQUIREMENTS X F. PRE-INSTALLED VERIFICATION TESTING BY INSTALLATION PERSONNEL OBSERVED AND DOCUMENTED FOR FASTENER ASSEMBLIES AND METHODS USED X G. PROTECTED STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS AND OTHER FASTENER COMPONENTS X 5. INSPECTION TASKS DURING BOLTING (TABLE N5.6-2) A. FASTENER ASSEMBLIES PLACED IN ALL HOLES AND WASHERS AND NUTS ARE POSITIONED AS REQUIRED X B JOINT BROUGHT TO TH SNUG-TIGHT CONDITION PRIOR TO THE PRETENSIONING OPERATION X C FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROM ROTATING X D FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC SPECIFICATION, PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID POINT TOWARDS THE FREE EDGES X 6. INSPECTION TASKS AFTER BOLTING (TABLE N5.6-3) A. DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS X 7. INSPECTOR SHALL BE ON PREMISES FOR INSPECTION DURING THE PLACEMENT OF ANCHOR RODS AND OTHER EMBEDMENTS SUPPORTING STRUCTURAL STEEL. THE INSPECTOR SHALL INSPECT THE FABRICATED STEEL OR ERECTED STEEL FRAME, AS APPLICABLE, TO VERIFY COMPLIANCE WITH THE DETAILS SHOWN ON THE CONSTRUCTION DOCUMENTS (SECTION N5.7) X 1. THE OWNER OR THE OWNER'S AUTHORIZED AGENT, OTHER THAN THE CONTRACTOR, SHALL EMPLOY ONE OR MORE APPROVED AGENCIES TO PROVIDE SPECIAL INSPECTIONS AND TESTS DURING CONSTRUCTION ON THE TYPES OF WORK SPECIFIED PER IBC SECTION 1705 AND IDENTIFY THE APPROVED AGENCIES TO THE BUILDING OFFICIAL. SPECIAL INSPECTIONS ARE REQUIRED AS FOLLOWS: SPECIAL INSPECTION ITEMS: SPECIAL INSPECTION AND TESTS OF SOILS (IBC TABLE 1705.6) TYPE CO N T I N U O U S PE R I O D I C 1.VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY.X 2.VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL.X 3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS. X 4. DURING FILL PLACEMENT, VERIFY USE OF PROPER MATERIALS AND PROCEDURES IN ACCORDANCE WITH THE PROVISIONS OF THE APPROVED GEOTECHNICAL REPORT. VERIFY DENSITIES AND LIFT THICKNESS DURING PLACEMENT AND COMPACTION OF COMPACTED FILL. X 5.PRIOR TO PLACEMENT OF COMPACTED FILL, INSPECT SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY.X 2. QUALITY ASSURANCE PROGRAM: A. THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED TO BE CERTAIN IT CONFORMS WITH THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS. B. THE SPECIAL INSPRECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL, AND TO THE STRUCTURAL ENGINEER OF RECORD. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, ID UNCORRECTED, TO THE DESIGN AUTHORITY AND THE BUILDING OFFICIAL. S pe cial Inspe ctor ne e ds to b e ide ntifie d as pe r S e ction17 04 .2 .1 FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. SECTION FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. WINDOW OPENING DOOR OPENING BAR SIZE CLASS B TENSION SPLICE LENGTHS f'c = 3,000 PSI f'c = 4,000 PSI f'c = 5,000 PSI #3 #4 #5 #6 #7 #8 #9 #10 NOTES: A A HOLDOWN X TRENCH PARALLEL TO CONTINUOUS STRIP FOOTING PIPE PASSING UNDER WALL FOOTING IN SHALLOW TRENCH PIPE PASSING BELOW FOOTING IN DEEP TRENCH TYPICAL DETAIL FOR FOUNDATION EMBEDMENT TYPICAL CONCRETE CORNER TYPICAL CONCRETE CORNER SAWCUT JOINT KEYED JOINT CONTROL JOINTS IN CONCRETE SLAB ON GRADE TYPICAL PIPE THROUGH STEM WALLTYPICAL REINFORCING DETAILS STEEL REINFORCING LAP SPLICES IN CONCRETE STRAP AT OPENING IN SHEARWALL ELEVATION-TYPICAL 1-STORY SHEARWALL PLAN VIEW - HOLDOWN LOCATIONS/SHEARWALL END POSTS, "HD" TYPE HOLDOWNS USING SCREWS TYPICAL BEAM POCKET T1 TD01 NO SCALE T2 TD02 NO SCALE T3 TD03 NO SCALE T4 TD04 NO SCALE T6 TD05 NO SCALE T7 TD06 NO SCALE T8 TD07 NO SCALE T5 TD61 NO SCALET9TD10NO SCALE T10 TD14 NO SCALE T11 TD17 NO SCALE T12 TD19 NO SCALE T13 TD16 NO SCALE T14 TD26 NO SCALE KEYNOTES: NOTE: KEYNOTES: NOTE: KEYNOTES: NOTE: KEYNOTES: NOTE: KEYNOTES: KEYNOTES: KEYNOTES: NOTE: NOTE: KEYNOTES: KEYNOTES: KEYNOTES: KEYNOTES: NOTE: KEYNOTES: KEYNOTES: HORIZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HORIZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HORIZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS 12" 12" 12" 12" 12" 12" 19" 15" 17" 13" 15" 12" 29" 23" 26" 20" 23" 18" 32" 25" 28" 21" 25" 19" 54" 41" 47" 36" 42" 32" 70" 54" 61" 47" 54" 42" 89" 68" 77" 59" 69" 53" 112" 87" 97" 75" 87" 67" 1' - 0 " MI N 24" MIN BEYOND OPENING (TYP) 24" MIN BEYOND OPENING (TYP) 1.FINISHED GRADE WHERE OCCURS 2. DO NOT EXCAVATE A TRENCH CLOSER THAN A 45° ANGLE TO BELOW BOTTOM FOOTING OR FOUNDATION 3.BOTTOM OF CONCRETE FOOTING 4. BOTTOM OF TRENCH A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPE OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS 1.CONCRETE FOOTING 2.SLEEVE - PROVIDE 1/2" MINIMUM CLEARANCE AROUND PIPE OR CONDUIT 3.PIPE OR CONDUIT 4. CONCRETE FILL TO BE PLACED BEFORE FOOTING IS POURED - FORM SAME AS FOOTING AND POUR FULL WIDTH OF PIPE TRENCH 5.STEM WALL A.NO PIPE SHALL PASS THRU FOOTING OR UNDER COLUMN FOOTINGS. FOR TRENCHES GREATER THAN 3'-6" BELOW BOTTOM OF FOOTING, SEE PIPE PASSING BELOW WALL FOOTING DETAIL. 1. STEM WALL 2. CONCRETE FOOTING 3.1'-6" MAXIMUM (WHERE TRENCH EXCEEDS 1'-6" NOTIFY STRUCTURAL ENGINEER PRIOR TO PLACEMENT OF FOOTINGS) 4.BACKFILL AND RECOMPACT TRENCH PER SOILS REPORT AND SPECIFICATIONS 5.BOTTOM OF TRENCH A. DO NOT UNDERCUT EXISTING FOOTINGS B. NO PIPES OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS 1. SLOPED FINISH GRADE 2.MINIMUM FOOTING DEPTH PER G.S.N. (12" MINIMUM) 3.DEEPEN FOOTING AS REQUIRED TO ACCOUNT FOR SLOPED GRADE 4.CONCRETE FOOTING A. FOR ADDITIONAL INFORMATION, SEE PLANS AND DETAILS 1.CORNER DOWELS TO MATCH HORIZONTAL REINFORCEMENT 2.CONCRETE WALL WITH REINFORCEMENT 3. LAP SPLICE PER TYPICAL STEEL REINFORCING LAP SPLICES IN CONCRETE DETAIL 1. CORNER DOWELS TO MATCH HORIZONTAL REINFORCEMENT 2.CONCRETE WALL WITH REINFORCEMENT 3.LAP SPLICE PER TYPICAL STEEL REINFORCING LAP SPLICES IN CONCRETE DETAIL 1. CONCRETE SLAB ON GRADE 2.CONT KEYED JOINT 3.SAWCUT 1/8" WIDE x 1/4 SLAB THICKNESS IN DEPTH - CUT SHALL BE MADE SOON ENOUGH TO PREVENT SHRINKAGE CRACKING, BUT NOT SO SOON AS TO CAUSE SPALLING OF THE CONCRETE WHILE SAWING. WORK MUST BE COMPLETE WITHIN 16 HOURS OF CONCRETE PLACEMENT. A.KEYED JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING PLACEMENT UNLESS SPECIFICALLY NOTED ON THE PLANS.B."TOOL WET JOINT", "ZIP STRIP", ETC SHALL MATCH SAWCUT REQUIREMENTS A. NO PIPE SHALL PASS THROUGH FOOTINGS OR UNDER COLUMN FOOTINGS. FOR ADDITIONAL INFORMATION SEE PLANS AND DETAILS B.MULTIPLE PIPES/CONDUIT SLEEVES ALLOWED PROVIDED SLEEVES ARE SPACED W/ MINIMUM OF 2x SLEEVE DIAMETER BETWEEN SLEEVESC. SLEEVES SHALL NOT OCCUR WITHIN 12" OF POINT LOADS OR HOLDOWN ANCHORS 1. WALL AS OCCURS, SEE PLAN 2. SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3.SLEEVE, 8"∅ MAX, PROVIDE 1/2" MINIMUM CLEARANCE AROUND PIPE-CONDUIT 4.CONCRETE WALL, SEE PLAN 5. CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.PIPE OR CONDUIT 1. LAP - SEE G.S.N. FOR MASONRY AND TYPICAL DETAIL FOR CONCRETE 2.MAXIMUM 1/5 LAP BUT NOT MORE THAN 6" 3. WIRE TIES 4.1d (1" MINIMUM) 5.RADIUS = 3d FOR BARS NOT OVER #8; 4d FOR #9, #10, AND #11 BARS; 5d FOR #14 AND #18 BARS, 5d FOR ALL GRADE 40 BARS WITH 180 DEGREE HOOK 6.4D (4" MINIMUM) 7. 12d (90 DEGREE HOOK) 8.6d (4" MINIMUM) 9.135 DEGREE BEND 10.BEND AROUND 1 1/2" PIN FOR #3 BARS. BEND AROUND 2" PIN FOR #4 BARS. BEND AROUND 21/2" PIN FOR #5 BARS. 1. TOP BARS ARE ANY HORIZONTAL BARS PLACED SO THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT. 2. UNLESS NOTED OTHERWISE, LAP SPLICES IN CONCRETE BEAMS, SLABS AND WALLS SHALL BE CLASS "B" TENSION LAP SPLICES. 1. SHEATHING MATERIAL 2. SHEARWALL END POST (DBL STUD AT HOLDOWN U.N.O.) 3.EDGE NAILING AT ALL SHEATHING PANEL EDGES - STAGGER NAILS AT DOUBLE STUD END POSTS 4.FULL HEIGHT WOOD STUDS 5.ANCHOR BOLTS TO FOUNDATION OR NAILS TO LOWER FRAMING PER SHEARWALL SCHEDULE 6.SIMPSON STRAP TYPE HOLDOWN, WHERE OCCURS 7.SOLID BLOCKING AND EDGE NAILING REQUIRED AT PLYWOOD SHEET EDGES 8.CONT 2x PT SOLE PLATE 9.FIELD NAILING AWAY FROM PANEL EDGES 10.WOOD HEADER 11. TRIMMER STUD UNDER HEADER AND SILL, PROVIDE ADDITIONAL TRIMMER STUDS WHERE INDICATED ON PLANS 12.FULL HEIGHT KING STUD, PROVIDE ADDITIONAL KING STUDS WHERE INDICATED ON PLANS 13.2x BLOCKING FOR STRAP NAILING 14. STRAP, PER PLAN, ABOVE AND BELOW OPENING AS SHOWN 1.SHEATHING MATERIAL 2.DOUBLE STUDS AT EACH END OF SHEARWALL, EDGE NAIL ALONG DOUBLE STUDS 3.FULL HEIGHT WOOD STUDS 4. BOTTOM PLATE ATTACHMENT 5.SIMPSON STHD TYPE HOLDOWN 6.MIDHEIGHT BLOCKING AND EDGE NAILING REQUIRED 7. SIMPSON "PHD" TYPE HOLDOWN 8. FINISHED FLOOR 9.CONT 2x PT SOLE PLATE A.ALL CONDITIONS MAY NOT BE SHOWN. FOR CONDITIONS NOT SHOWN, USE THESE DETAILS AS A GUIDE. B.SOME LARGER HOLDOWNS REQUIRE 6x6 POSTS, SEE PLANS AND SCHEDULES. C. WHERE MULTIPLE TRIMMER STUDS OR KING STUDS OCCUR, MAKE ADJUSTMENTS AS REQUIRED. 1.WOOD STUD WALL, SEE PLAN 2. SHEARWALL SHEATHING, SEE PLAN 3. EDGE OF FOUNDATION 4.SIMPSON HD TYPE HOLDOWN WITH SCREWS 5.SHEARWALL END POST (2 STUDS) TYPICAL, EXCEPT AT HDU11, AND HDU14 WHERE 6x6 POST IS REQUIRED 6.25) - SIMPSON SDS 1/4"x6" LONG WOOD SCREWS, STAGGERED 7.SHEARWALL EDGE NAILING 8. TRIMMER STUD TO SUPPORT HEADER 9.BLOCK TO SUPPORT WINDOW SILL 10.BUILT UP WOOD POST 1.WOOD BEAM 2.(2) 16d NAILS AT 2" O.C. 3. KING STUD EACH SIDE OF BEAM 4.SOLID BUILT-UP POST BELOW BEAM 5.STRAP BROKEN TOP PLATE ON SIDE OR TOP 6.CONT DBL 2x TOP PLATE W/ LAP SPLICE PER TYPICAL DETAIL 7.FULL-HEIGHT KING STUD EACH SIDE OF BEAM 8.HGA10 CLIP EACH SIDE 9.FULL-HEIGHT KING STUD AT END OF BEAM 10. FULL-HEIGHT KING STUD, OPPOSITE SIDE OF THE BEAM 1 1 4 3 2 1 6" M I N 8" M I N 3' - 0 " M A X 8" MIN 5 1 2 3 4 5 1 2 3 4 3' - 1 " O R G R E A T E R 5 3 2 1 44 1 5'-0" 1 2 3 4 2 1 3 3 (TYP) (T Y P ) 2 1 1 3 3 12"6" 6"12" 1 3 1 2 1 7 3 4 5 6 22 6 MIN BAR OFFSET BAR CLEARANCE SPLICE DETAIL BEND & HOOK DETAILS COLUMN TIES BEAM STIRRUPS "d" 45° "d" "d" 1 8 8 3 1 2 4 6 7 5 55 5 99 10 10 6 8 FINISHED FLOOR 1 2 14 4 3 12 13 2 3 6 8 9 1111 3 10 77 5 OPEN 1 3 6 8 7 4 5 2 9 (2) SHEARWALLS (1) "HD" HOLDOWN W/SCREWS "HD" HOLDOWN W/SCREWS WINDOW JAMB X "HD" HOLDOWN W/SCREWS DOOR JAMB OR WALL END X HD19 2-1/8" 1-5/16"HDU2, HDU4, HDU5 HTT4 HTT5 1-5/16" (2) SHEARWALLS (1) "HD" HOLDOWN W/SCREWS AT EXTERIOR CORNER X (1) SHEARWALL (1) "HD" HOLDOWN W/SCREWS AT EXTERIOR CORNER X AT RE-ENTRANT CORNER X (1) SHEARWALL (1) "HD" HOLDOWN W/SCREWS AT RE-ENTRANT CORNER X 4 HDU14 1-9/16" LTT20B LTT19 1-3/8" 1-1/2" HDU8, HDU11 1-3/8" 3 2 7 4 1 3 2 7 7 2 1 981 3 4 4 8 3 1 4 7 2 3 6 3 2 77 32 410 5 5 5 5 5 5 5 3 3 1 2 7 2 7 3 6 1 2 6 34 1 5 2 1 74 2 1 3 4 18 AT BEAM AT MID WALL AT TOP PLATE 2 1 4 AT CORNER 10 9 2 N O TF O R C O N S T R U C T I O N P U R P O S E S PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : DBP 4/ 5 / 2 0 2 3 9 : 2 5 : 3 0 A M A u t o d e s k D o c s : / / 2 3 - 0 3 8 _ B e e h i v e F ed e r a l C r e d i t U n i o n R e x b u r g / I F 2 3 - 0 3 8 _ B e e h i v e F e d e r a l C r e d i t U n i o n R e x b u r g . r v t S1.2 23-038 BE E H I V E F C U -N O R T H R E X B U R G TY P I C A L D E T A I L S 02/23/2023 AV SECTION OPTION 1 OPTION 2 OPTION 3 FLANGE WIDTH: WEB STIFFENER THICKNESS: NOTES: 11 7/8" OR LESS 14" OR GREATER 11 7/8" OR LESS 14" OR GREATER NOTES: KEYNOTES: KEYNOTES: KEYNOTES: KEYNOTES: KEYNOTES: KEYNOTES: NOTE: ALL-THREAD ANCHOR DIAMETER MINIMUM EMBEDMENT MINIMUM VERTICAL BARS (PROVIDE ADDITIONAL VERTICAL BARS AS REQUIRED) ALTERNATE SIMPSON ANCHOR TYPE (INSTALL PER MANUFACTURER) ANCHOR SCHEDULE BRICK VENEER STEEL ANGLE LINTEL SCHEDULE ELEVATION - TYPICAL TOP PLATE SPLICE TYPICAL HEADER CONNECTION MINIMUM NAILING SCHEDULE - UNLESS NOTED OTHERWISE TYPICAL ANCHORAGE FOR "HD" TYPE HOLDOWN TYPICAL WALL PENETRATION LESS THAN 10" SQUARE AT SHEARWALL TYPICAL BUILT-UP BEAM DETAIL 2-PLY BEAM 3-PLY BEAM TYPICAL ROOF SNOW SURCHARGE / DRIFT LOAD TYPICAL STRAP AT WOOD BEAM LOCATIONS REQUIRING ADDITIONAL SLAB REINFORCEMENT (PLAN VIEW) TYPICAL WEB STIFFENER REQUIREMENTS ELEVATION ELEVATION ELEVATION ELEVATION ELEVATION PLAN - STEEL COLUMN AT WOOD STUD WALL BRICK VENEER STEEL ANGLE LINTEL STRAPPING W/ BLOCKING ACROSS DIAPHRAM TYPICAL WOOD TRUSS AT NON-BEARING WALL T15 TD24 NO SCALE T16 TD25 NO SCALE T17 TD34 NO SCALE T18 TD56 NO SCALE T19 TD78 NO SCALE T20 TD80 NO SCALE T21 TD73 NO SCALE T23 TD68 NO SCALE T22 TD82 NO SCALE T24 TD76 NO SCALE T25 TD39 NO SCALE T26 TD55 NO SCALE T27 NO SCALE T28 TD74 NO SCALE LENGTH OF WALL (BETWEEN CORNERS) SPLICE LENGTH NAILS ALONGSPLICE LENGTH MINIMUM CONNECTION TYPENAILING LAP SPLICE KEYNOTES: NOTE: KEYNOTES: NOTE: KEYNOTES: KEYNOTES: NOTE: KEYNOTES: WEB STIFFENER THICKNESS SCHEDULE: KEYNOTES: 1/2"12" --- --- 5/8"16" (1) #5 OR (2) #4 SB5/8X24 7/8"18" (2) #5 SSTB34 OR SB7/8X24 1" 20" (2) #6 SB1X30 OPENING WIDTH ANGLE SIZE UP TO 7'-0"L31/2x31/2x1/4 7'-1" TO 9'-0"L5x31/2x1/4 (LLV) 9'-1" TO 10'-0"L5x3 1/2x5/16 (LLV) 10'-1" TO 11'-0"L5x31/2x3/8 (LLV) 11'-1" TO 12'-0"L6x4x3/8 (LLV) 12'-1" AND OVER SPECIAL ANALYSIS REQUIRED SPLICE LENGTH PER SCHEDULE 4" MAX 2" MI N EM B E D M E N T 4" 3_ 4 " G A P M I N 1.NAILS BETWEEN SPLICE LOCATION PER SCHEDULE - STAGGERED 2.DBL 2x TOP PLATE 3.WOOD STUD WALL, SEE PLAN 4. SPLICE OVER STUD 5.SIMPSON ST6224 OR MSTC40 STRAP AT LOCATIONS WHERE PLATES CAN NOT BE SPLICED A.DO NOT SPLICE TOP PLATES WITHIN 6'-0" OF ENDS OF PLYWOOD SHEARWALLS. THIS DETAIL REQUIRED AT ALL EXTERIOR WALLS AND OVER SHEARWALLS - NOT REQUIRED AT INTERIOR NON-SHEARWALLS. 1.WOOD STUD WALL, SEE PLAN 2. WOOD HEADER 3.KING STUD(S) PER PLAN 4.(2) 16d NAILS AT 2" O.C. 5. 16d NAILS AT 12" O.C. 6.TRIMMER STUD(S) PER PLAN A.MINIMUM NAILING SPECIFIED HEREIN SHALL BE PROVIDED UNLESS NOTED OTHERWISE ON PLANS, DETAILS OR GENERAL STRUCTURAL NOTES B.NAILING NOT NOTED ON THESE PLANS OR DETAILS SHALL BE PER I.B.C. TABLE 2304.10.1 1.HOLDOWN ANCHOR BOLT 2.TOP OF CONCRETE OR COLD JOINT 3.DBL NUT AND 2"∅ PLATE WASHER 4.ADDITIONAL VERTICAL BAR(S), SEE SCHEDULE 5.TOP REINFORCING BAR (#4 BAR MINIMUM) PER PLAN 1.SURCHARGE OR DRIFT SNOW LOAD AREA, SEE PLAN 2.BALANCED ROOF SNOW LOAD, SEE GSN 3.REQUIRED LOAD INCREASE, SEE PLAN 4. EXTENT OF SURCHARGE OR DRIFT LOAD, SEE PLAN A. SURCHARGE AND DRIFT LOADS ARE IN ADDITION TO ROOF BALANCED SNOW LOAD ##PSF ##PSF 1.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 2.TRIMMER AND KING STUDS, SEE PLAN 3. WOOD BEAM, SEE PLAN 4.STRAP, SEE PLAN 13/4"5/8" 21/16"3/4" 25/16"7/8" 31/2"2x4 DF NO.2 OR BETTER (ORIENTED VERTICAL) 1.STEEL COLUMN, SEE PLAN 2.2x NAILER W/5/8" THREADED STUD AT 12" O.C. 3. EDGE NAILING, SEE SHEARWALL SCHEDULE 4.WALL SHEATHING AS OCCURS, SEE PLAN 1. ANGLES ARE TO BE HOT DIPPED GALVANIZED. 2. LINTELS CARRY BRICK OR STONE ONLY. WHERE FLOORS, ROOFS, OR CONCENTRATED LOADS OCCUR ABOVE, FURTHER ANALYSIS IS NECESSARY. 3. PROVIDE 1" OF BEARING EACH END FOR EACH FOOT OF SPAN (6" BEARING EACH SIDE OF OPENING MINIMUM). 4. USE THIS SCHEDULE UNLESS NOTED OTHERWISE (30) 16d (24) 16dLESS THAN 20' OVER 20' 4'-0" 6'-0" 4 5 1 3 2 3 2 2 6 3 1 5 4 5 JOIST OR TRUSS BEARING ON SILL OR GIRDER BRIDGING TO JOIST SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL TOP PLATE TO STUD DOUBLE STUDS, FACE NAIL DOUBLE TOP PLATES CONTINUOUS HEADER TO STUD CEILING JOISTS, LAPS OVER PARTITIONS CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL RAFTER OR TRUSS TO PLATE BUILT-UP CORNER STUDS TOENAIL (4)-8d COMMON (2 1/2" x 0.131") (3)-8d COMMON (2 1/2" x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES TOENAIL EACH END(2)-3"x 0.131" NAILS (Gun Nail) (2)-3"x 14 GAUGE STAPLES 16d (3 1/2"x 0.135") AT 16" O.C. FACE NAIL 3"x 14 GAUGE STAPLES AT 12" O.C. 3"x 0.131" NAILS (Gun Nail) AT 8" O.C. END NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES SOLE PLATE TO STUD END NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES FACE NAIL 16d (3 1/2"x 0.135") AT 24" O.C. 3"x 14 GAUGE STAPLES AT 8" O.C. 3"x 0.131" NAILS (Gun Nail) AT 8" O.C. FACE NAIL 16d (3 1/2"x 0.135") AT 16" O.C. 3"x 14 GAUGE STAPLES AT 12" O.C. 3"x 0.131" NAILS (Gun Nail) AT 12" O.C. DOUBLE TOP PLATES - FACE NAIL (8)-16d COMMON (3 1/2"x 0.162") (12)-3"x 0.131" NAILS (Gun Nail) (12)-3"x 14 GAUGE STAPLES RIM JOIST TO TOP PLATE 8d (2 1/2"x 0.131") AT 6" O.C. 3"x 14 GAUGE STAPLES AT 6" O.C. 3"x 0.131" NAILS (Gun Nail) AT 6" O.C. BLOCKING BETWEEN JOISTS OR RAFTERS TOENAIL (3)-8d COMMON (2 1/2"x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES AND TOP PLATE TOENAIL TOP PLATES, LAPS AND INTERSECTIONS FACE NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES CONTINUOUS HEADER, TWO PIECES 16d COMMON (3 1/2"x 0.162")FACE NAIL AT 16" O.C. ALONG EDGES CEILING JOISTS TO PLATE TOENAIL (3)-8d COMMON (2 1/2"x 0.131") (5)-3"x 0.131" NAILS (Gun Nail) (5)-3"x 14 GAUGE STAPLES FACE NAIL (3)-16d COMMON (3 1/2"x 0.162) (4)-3"x 0.131" NAILS (Gun Nail) (4)-3"x 14 GAUGE STAPLES (3)-16d COMMON (3 1/2"x 0.162) (4)-3"x 0.131" NAILS (Gun Nail) (4)-3"x 14 GAUGE STAPLES FACE NAIL (3)-8d COMMON (2 1/2"x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES TOENAIL TOENAIL 16d COM.(3 1/2"x 0.162") AT 24" O.C. 3"x 14 GAUGE STAPLES AT 16" O.C. 3"x 0.131" NAILS (Gun Nail) AT 16" O.C. FACE NAIL (2)-8d COMMON (2 1/2" x 0.131") USE- SIMPSON A35 AT 48" O.C.-NA- SIMPSON A35 AT EVERY OTHER BLOCK -NA- 1 2 4 3 5 1. SHEATHING MATERIAL 2. WOOD STUD WALL 3.5" TO 10" SQUARE OPENING, PROVIDE FULL DEPTH BLOCKING ON SIDE, TOP AND BOTTOM W/ EDGE NAILING 4.EDGE NAILING 5.5" OR SMALLER SQUARE OPENING, NO BLOCKING W/ EDGE NAILING REQUIRED 1 2 444 3 5 1. MAXIMUM ACCUMULATED LENGTH OF OPENINGS SHALL NOT EXCEED 10% OF WALL LENGTH. 1.(2) 10d NAILS AT 8" O.C., EACH SIDE, STAGGERED 2. (3) 10d NAILS AT 8" O.C., EACH SIDE, STAGGERED 3.(2)1/4"∅ x 3 1/2" SDS AT 12" O.C., EACH SIDE, STAGGERED 4.(3)1/4"∅ x 3 1/2" SDS AT 12" O.C., EACH SIDE, STAGGERED 2 1 3 4 3 3 1 2 4 3 4 2 1 1 3 4 2 1 2 3 4 1. CONTROL OR CONSTRUCTION JOINT 2. DEPRESSED CONCRETE SLAB 3. (2) #4x4'-0" BARS AT EACH CORNER OF DEPRESSED SLAB WHERE CONTROL/CONSTRUCTION JOINTS DO NOT EXTEND FROM CORNER4.(2) #4x4'-0" BARS WHERE CONTROL/CONSTRUCTION JOINTS DO NOT CONTINUE BEYOND INTERSECTION 5. EXTERIOR WALL CORNER 6.INTERIOR SLAB ON GRADE, SEE PLAN 7.(2) #4x4'-0" AT EXTERIOR WALL CORNER WHERE CONTROL/CONSTRUCTION JOINTS DO NOT INTERSECT CORNER 1 2 3 11 4 7 6 5 1.WOOD I-JOIST, SEE PLAN 2.BEARING LOCATION, SEE PLAN 3. FLOOR / ROOF SHEATHING W/ ATTACHMENT, SEE PLAN 4.CONT RIM BOARD W/ ATTACHMENT, SEE CORRESPONDING DETAILS 5.WEB STIFFENERS AS REQUIRED, SEE PLAN / CORRESPONDING DETAILS. WHEN WEB STIFFENERS ARE REQUIRED, PLACE ON EACH SIDE OF WEB UNO 6.21/2" MIN WEB STIFFENER WIDTH 7.GAP BETWEEN TOP OF WEB STIFFENER AND BOTTOM OF TOP FLANGE OF WOOD JOIST MIN GAP =1/8" MAX GAP = 2" 8.WEB STIFFENER TO FIT TIGHT AGAINST FLANGE OF WOOD I-JOIST 9. I-JOIST FLANGE WIDTH 10.WEB STIFFENER THICKNESS PER SCHEDULE 11.(3) ROWS CLINCHED FASTENERS. FOR FLANGE WIDTHS 1 3/4" - 25/16", USE 8d (0.113"x21/2") FASTENERS AND FOR 31/2" FLANGE WIDTHS, USE 16d (0.135"x31/2") FASTENERS 12.1" SPACE FOR FLANGE WIDTHS 1 3/4" - 25/16" AND 1 1/2" SPACE FOR 3 1/2" FLANGE WIDTH 13. BEVELED WEB STIFFENERS AS REQUIRED, SEE PLAN / COORESPONDING DETAILS. WHEN WEB STIFFENERS ARE REQUIRED, PLACE ON EACH SIDE OF WEB UNO 14.CONT SHAPED BEARING PLATE. SEE COORESPONDING DETAILS 15.I-JOIST HANGER, SEE PLAN 16. WEB STIFFENERS REQUIRED WHERE HANGER SIDES DO NOT EXTEND TO LATERALLY SUPPORT 3/8" MIN OF TOP FLANGE OF I-JOIST OR AS SPECIFIED, SEE PLAN / CORRESPONDING DETAILS. WHEN WEB STIFFENERS ARE REQUIRED, PLACE ON EACH SIDE OF WEB 17. CONCENTRATED LOAD IN CLR SPAN OF JOIST, SEE PLANS AND DETAILS FOR ADDITIONAL INFORMATION 2 1 3 6 5 7 8 4 7 5 7 5 8 1 9 1010 8 11 12 12 1 2 3 12 3 5 8 7 6 5 8 14 2 3 1 8 7 16 15 6 7 1 3 17 5 8 7 433 21 2 1. WOOD TRUSS/JOIST, SEE PLAN 2.BLOCKING BETWEEN EACH TRUSS TOP CHORD 3. STRAP W/ NAILING, SEE PLAN 2 3 1 1. WOOD TRUSS 2. HTC4 CLIP AT WALL ENDS AND AT 48" O.C. (MAX) REMAINDER 3.DBL TOP PLATE AT NON-BEARING WALL A.NAILS SHOULD NOT BE DRIVEN COMPLETELY FLUSH AGAINST THE CONNECTOR AT THE TRUSS TO ALLOW VERTICAL TRUSS MOVEMENT, ALLOW 1/16" GAP BETWEEN NAIL HEAD AND TRUSS CLIP B.ARCH TO PROVIDE FINISH TO ALLOW FOR 3/4" VERTICAL MOVEMENT OF TRUSS 1 2 3 N O TF O R C O N S T R U C T I O N P U R P O S E S PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : DBP 4/ 5 / 2 0 2 3 9 : 2 5 : 3 0 A M A u t o d e s k D o c s : / / 2 3 - 0 3 8 _ B e e h i v e F ed e r a l C r e d i t U n i o n R e x b u r g / I F 2 3 - 0 3 8 _ B e e h i v e F e d e r a l C r e d i t U n i o n R e x b u r g . r v t S1.3 23-038 BE E H I V E F C U -N O R T H R E X B U R G TY P I C A L D E T A I L S 02/23/2023 AV CONCRETE SLAB ON GRADE CONCRETE SLAB ON GRADE W/ EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME FINISH FLOOR = 100'-0" 4"#3 AT 18" O.C. 6 4 3 1 2 ABDE 5 C AABBCC 3.5 4.8 1.5 D.1 C.1 B.1 SC3 SC3 SC3 SC3 SC3SC3 SC3 SC3 SC3 SC2 SC4 SC2 F36 F72 F72 F36 F72 F72 F72 F72F72F72 F72 F72 F72 SC2 F36 SC2 F36 SC1SC1 SC1 SC1 SC2 F36 SC2 F36 SC2 SC2 SC21'-2" F48 F36 46'-10" 5"14'-0"12'-2"7'-4"13'-4" 5 1/4" 52 ' - 8 3 / 4 " 11 ' - 5 " 8 " 8 " 1 0 ' - 4 " 10 ' - 4 " 4" 1' - 0 " 3 ' - 1 0 " 1 4 ' - 1 3 / 4 " 7 1 / 4 " 2'-0" 2'-0" 8 1/2" 1' - 4 " 20 ' - 8 " 1' - 4 " 2'-0" 2'-8 1/2" 8" 14'-0"12'-2" 2'-5 1/4" 3'-4" 1'-6 3/4" 13'-4" 5 1/4" 11'-0"11'-0"11'-10" 46'-10" 3'-0 1/2" 14 ' - 4 " 14 ' - 4 " 14 ' - 4 " 9' - 8 3 / 4 " 4'-4" 7'-8" 7' - 0 " 4 ' - 0 " WF24A WF24A WF18 WF18 WF24A WF24A WF18 WF24 WF18 WF18 WF24A WF 2 4 A WF 1 8 WF 2 4 A WF 1 8 WF 1 8 WF 2 4 WF 1 8 WF 2 4 WF 2 4 F72 / W2 / W2 / W1 / W1 / W1 / W2 / W1 /W1 /W1 /W1 /W1 /W1 /W1 /W1WF24 55 5 6. 6.6. 6. 5 5 5 6. 6. 5 5 5 5 6. 6. 5 5 101 S3.0 ________________________102 S3.0 ________________________ 102 S3.0 ________________________ 101 S3.0 ________________________ 101 S3.0 ________________________ 101 S3.0 ________________________ 105 S3.0 ________________________ 106 S3.0 ________________________ 104 S3.0 ________________________ 106 S3.0 ________________________ 104 S3.0 ________________________ 104 S3.0 ________________________ 104 S3.0 ________________________ 103 S3.0 ________________________ 101 S3.0 ________________________ 104 S3.0 ________________________ 106 S3.0 ________________________ 102 S3.0 ________________________ A A A A A B 110 S3.0 ________________________ 2' - 3 " 107 S3.0 ________________________ TYP B AA 6. 6.6. 6.6. B B 111 S3.0 ________________________ 110 S3.0 ________________________ S3.0 109 TYP S3.0 109 TYP S3.1 114 S3.0 108 S3.1 113 T.O.F. = 97'-0" A 1 TYP 8 1 / 2 " 6 ' - 3 1 / 2 " 3 ' - 3 1 / 2 " 103 S3.0 ________________________ 4" S3.1 112 T.O.F.=99'-4" T.O.F.=99'-4" T.O.F.=99'-4" 7 1 / 4 " 12 ' - 1 " 11 ' - 0 " 10 ' - 8 " 4 ' - 1 0 " 1 4 ' - 1 3 / 4 " 5 1 / 4 " 3' - 6 3 / 4 " 8 1 / 2 " 2 3/4" PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : DBP 4/ 2 0 / 2 0 2 3 4 : 2 4 : 4 0 P M A u t o d e s k D o c s : / / 2 3 - 0 3 8 _ B e e h i v e Fe d e r a l C r e d i t U n i o n R e x b u r g / I F 2 3 - 0 3 8 _ B e e h i v e F e d e r al C r e d i t U n i o n R e x b u r g . r v t S2.0 23-038 BE E H I V E F C U -N O R T H R E X B U R G FO U N D A T I O N P L A N 02/23/2023 AV NORTH WALL (W) SCHEDULE TYPE MATERIAL THICKNESS VERTICAL REINFORCING HORIZONTAL REINFORCING REMARKS W1 CONCRETE 10" #4 AT 16" O.C. #4 AT 10" O.C. MIN ONE HORIZONTAL BAR IN TOP 6" WALL W2 CONCRETE 16" #4 AT 18" O.C. EACH FACE #4 AT 12" O.C. EA FACE MIN ONE HORIZONTAL BAR IN TOP 6" WALL FOOTING SCHEDULE MARK LENGTH WIDTH THICKNESS REINFORCING REMARKS F36 36" 36" 10" (4) #4 EACH WAY TOP & BOTTOM --- F48 48" 48" 10" (4) #5 EACH WAY TOP & BOTTOM --- F72 72" 72" 12" (8) #5 EACH WAY TOP & BOTTOM --- WF18 CONT 18" 10" (2) #4 CONT BOTTOM --- WF24 CONT 24" 10" (2) #4 CONT BOTTOM --- WF24A CONT 24" 10" (3) #4 CONT TOP & BOTTOM --- KEYNOTES 1 CONCRETE BOLLARDS PER ARCH FOUNDATION PLAN NOTES A. VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B. ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C. THE DEPTH OF FOOTING DIMENSION INDICATED IN THE G.S.N. IS A MINIMUM. FOUNDATION CONTRACTOR SHALL COORDINATE WITH THE SOILS REPORT AND OTHER TRADES TO INSURE THAT THESE MINIMUMS ARE SUFFICIENT FOR THE WORK. SEE TYPICAL DETAILS FOR ADDITIONAL REQUIREMENTS. D. W1, W2, ETC. - AS SHOWN ON PLAN INDICATES CONCRETE OR MASONRY WALLS. SEE WALL SCHEDULE FOR ADDITIONAL INFORMATION. E. WF18, WF24, ETC. - AS SHOWN ON PLAN INDICATES A CONTINUOUS WALL FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. F. F36, F48, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. . G. . , , - AS SHOWN ON PLAN INDICATES A SHEARWALL HOLDOWN. SEE HOLDOWN SCHEDULES AND DETAILS FOR ADDITIONAL INFORMATION. H. P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. I. SC1, SC2, ETC. - AS SHOWN ON PLAN INDICATES A STEEL COLUMN. SEE STEEL COLUMN SCHEDULE FOR ADDITIONAL INFORMATION. COLUMNS START AT THE LEVEL THEY ARE CALLED OUT ON. J. PROVIDE CONTINUOUS BEARING FOR ALL POSTS AND BUILT-UP STUDS TO THE FOUNDATION PER TYPICAL "SOLID BLOCKING BETWEEN FLOORS" DETAIL. K. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. L. VERIFY EXACT SIZE AND LOCATION OF DEPRESSED AND/OR RAISED SLABS WITH ARCHITECTURAL DRAWINGS. M. FOR SIDEWALK AND LANDING LOCATIONS, SEE ARCHITECTURAL DRAWINGS. N. TYPICAL TOP OF CONCRETE WALL=100'-0" O. TYPICAL TOP OF EXTERIOR FOOTING=97'-0" P. TYPICAL TOP OF INTERIOR FOOTING=99'-8", UNO HOLDOWN SCHEDULE MARK HOLDOWN SHEARWALL END POST UNO ON PLAN ALTERNATE HOLDOWN ANCHOR BOLT DIA. A SIMPSON HTT4 W/ (18) 0.162x2.5" NAILS (2) 2x STUDS N/A 5/8" B SIMPSON HDU8 (2) 2x STUDS N/A 7/8" SCALE: 1/4" = 1'-0" FOUNDATION PLAN 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. NOTES: SHEARWALL TYPE SCHEDULE MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 5 7/16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 6. 7/16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 4" O.C. 8d COMMON AT 12" O.C. CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 24" O.C. CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 32" O.C. WOOD: 16d STAGGERED AT 4" O.C. STEEL COLUMN (SC) SCHEDULE MARK SIZE BASE CONNECTION SC1 HSS4x4x1/4 PER DETAIL, SEE PLAN SC2 HSS5x5x1/4 3/4"x11"x11" PLATE W/ (4) 3/4" DIA ANCHOR BOLTS W/ 8" MIN EMBEDMENT, U.N.O. SC3 HSS6x6x1/4 PER DETAIL, SEE PLAN SC4 HSS6x6x5/8 3/4"x12"x12" PLATE W/ (4) 3/4" DIA ANCHOR BOLTS W/ 8" MIN EMBEDMENT, U.N.O. 1 CITY COMMENTS 04/20/2023 A B 1 Ap r i l 2 0 , 2 0 2 3 6 4 3 1 2 ABDE 5 C AABBCC 3.5 4.8 1.5 D.1 C.1 B.1 W8 x 1 3 W8 x 1 3 W8 x 1 3 WO O D R O O F T R U S S E S A T 2 4 " O . C . WO O D R O O F T R U S S E S A T 2 4 " O . C . WO O D R O O F T R U S S E S A T 2 4 " O . C . HSS14X4X3/16 CURVED HSS14X4X3/16 CURVED HSS6x3x3/16 CURVED WOOD TRUSS AT 24" O.C. 14" RED-L BARREL OPEN-WEB B1 B1 B1 B4 B2 B1 B3 B1 B4 B4 HSS8X6X1/4HSS6X2X1/4 FLAT HSS6X2X1/4 FLAT HS S 6 X 2 X 1 / 4 FL A T B7 B7 HSS3X3X3/16 FLAT W1 0 X 2 2 CU R V E D B2 B8 TYPICAL ROOF SHEATHING APA RATED ROOF SHEATHING W/ NAILS AT O.C. AT PANEL EDGES AND BOUNDARY AND AT O.C. IN THE FIELD. 19/32"8d 6" 12" B6 B1 B6 B1 B5B5 B1 B6 B1 B6 WJ 3 WJ 3 WJ 3 B1 1 1 40 PSF 0 PSF 8'-0" 30 PSF 0 PSF 6'-0" 30 PSF 0 PSF 6' - 6 " HS S 1 2 X 6 X 3 / 1 6 HS S 1 2 X 6 X 3 / 1 6 HS S 1 2 X 6 X 3 / 1 6 HS S 1 2 X 6 X 3 / 1 6 HSS14X4X3/16 CURVED TYP HSS14X4X3/16 CURVED TYP B1 55 5 6. 6.5 5 5 5 5 6. 6. 5 5 5 5 6. 6. 5 5 6. 2 2 B5 WJ1 2 2 WJ1 2 2 WJ 3 2 2 1 WJ 3 WJ2 WJ2 WJ2 WJ2 WJ2 232 S4.2 ________________________232 S4.2 ________________________ 233 S4.2 ________________________234 S4.2 ________________________233 S4.2 ________________________ 231 S4.2 ________________________ 234 S4.2 ________________________ 229 S4.2 ________________________ WJ3 B6 228 S4.2 ________________________ 222 S4.1 ________________________ SIM 220 S4.1 ________________________ 2 2 227 S4.1 ________________________ 221 S4.1 ________________________ B1 2 2 222 S4.1 ________________________ 220 S4.1 ________________________ B1 3 206 S4.0 ________________________ 3 205 S4.0 ________________________ 212 S4.0 ________________________ 205 S4.0 ________________________ B1 207 S4.0 ________________________ 3 211 S4.0 ________________________ 206 S4.0 ________________________ 240 S4.3 ________________________ 226 S4.1 ________________________ 215 S4.0 ________________________210 S4.0 ________________________ 214 S4.0 ________________________209 S4.0 ________________________ 226 S4.1 ________________________ 213 S4.0 ________________________ 235 S4.2 ________________________ 201 S4.0 ________________________ 217 S4.1 ________________________ 202 S4.0 ________________________ 236 S4.2 ________________________ 239 S4.3 ________________________238 S4.3 ________________________ 240 S4.3 ________________________ 236 S4.2 ________________________ 4 237 S4.2 ________________________236 S4.2 ________________________ 236 S4.2 ________________________236 S4.2 ________________________ B6 WJ3 230 S4.2 ________________________ P2 P1 P2 5 5 6. P1 6 6.6. 6 6. B1 CS16 7 5 6 B1 CS16 B3 8 CS16 B3 8 CS16 8 B1 CS16 B3 8 CS16 8 211 S4.0 ________________________ 9 9 8 B1 3 10 RA D I U S = 2 9 ' - 6 " T . O . S . N O TF O R C O N S T R U C T I O N P U R P O S E S PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : DBP 4/ 5 / 2 0 2 3 9 : 2 5 : 3 4 A M A u t o d e s k D o c s : / / 2 3 - 0 3 8 _ B e e h i v e F ed e r a l C r e d i t U n i o n R e x b u r g / I F 2 3 - 0 3 8 _ B e e h i v e F e d e r a l C r e d i t U n i o n R e x b u r g . r v t S2.1 23-038 BE E H I V E F C U -N O R T H R E X B U R G LO W E R R O O F F R A M I N G P L A N 02/23/2023 AV 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. NOTES: SHEARWALL TYPE SCHEDULE MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 5 7/16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 6. 7/16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 4" O.C. 8d COMMON AT 12" O.C. CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 24" O.C. CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 32" O.C. WOOD: 16d STAGGERED AT 4" O.C. BEAM (B) SCHEDULE MARK SIZE B1 (2) 2x6 OR 4x6 OR (2) 1 3/4x 5 1/2 LVL B2 (2) 2x8 OR 4x8 OR (2) 1 3/4x5 1/2 LVL B3 (2) 1 3/4x9 1/2 LVL OR 3 1/2x9 1/2 LVL B4 5 1/8x12 GLB B5 (1) 1 3/4x9 1/2 LVL B6 2x6 B7 5 1/8x6 GLB B8 5 1/8x12 GLB KEYNOTES 1 STRUCTURAL FASCIA, UNBROKEN FROM CORNER FOR 8'-0" MIN 2 INVERTED SIMPSON HUC26-2 HANGER 3 OPENING FOR MECHANICAL DUCT, COORDINATE W/ ARCH AND MECHANICAL. 4 ADD WOOD NAILER TO STEEL COLUMN PER "PLAN-STEEL COLUMN AT WOOD STUD WALL" TYPICAL DETAIL. 5 2x6 BLOCKING BETWEEN EACH JOIST W/ CS16x15'-0" STRAP AS SHOWN, SEE TYPICAL DETAIL 6 IN ADDITION TO BALANCED ROOF SNOW LOAD, TRUSS MANUFACTURER TO DESIGN TRUSSES FOR DRIFTING SNOW LOAD FOR LENGTH AND MAGNITUDE SHOWN, SEE TYPICAL DETAIL 7 DISCONTINUE NAILER AND THREADED STUDS AT OVERHANG 8 OPENING FOR MECHANICAL DUCT, COORDINATE W/ ARCH AND MECHANICAL. STRAP ABOVE AND BELOW MECHANICAL OPENING W/ CS16 SIM TO DETAIL T11 9 POCKET BEAM INTO WALL PER TYPICAL DETAIL 10 BRACE NON-BEARING WALL PER "TYPICAL WOOD TRUSS AT NON-BEARING WALL" DETAIL SCALE: 1/4" = 1'-0" LOWER ROOF FRAMING PLAN WOOD JOIST (WJ) SCHEDULE MARK WOOD JOIST JOIST SPACING (O.C.) FACE MOUNT HANGER TOP FLANGE HANGER WJ1 9 1/2" TJI 110 2'-0" LSSR1.81Z WJ2 14" TJI 110 2'-0" WJ3 2x6 2'-0" LUS26 LB26 NORTH ROOF FRAMING PLAN NOTES A. VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B. ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C. IF DOUBLE TOP PLATE IS NOTCHED, STEPPED OR BROKEN, PROVIDE A SIMPSON MSTC40 STRAP AT DISCONTINUITY. D. TYPICAL BEARING WALL FRAMING SHALL BE 2x6 STUDS AT 16" O.C. UNO. E. PROVIDE TRIMMER STUDS (TS) AND KING STUDS (KS) AT OPENINGS AS FOLLOWS, U.N.O.: OPENINGS 6'-0" OR LESS, (1) TS & (1) KS, OPENINGS 6'-1" TO 9'-0", (1) TS & (2) KS, 9'-1" TO 12-0", (2) TS & (3) KS. FOR ATTACHMENT, SEE "TYPICAL HEADER CONNECTION" DETAIL. F. B1, B2, ETC. - AS SHOWN ON PLAN INDICATES A BEAM OR HEADER. SEE BEAM SCHEDULE FOR ADDITIONAL INFORMATION. G. WJ1, WJ2, ETC. - AS SHOWN ON PLAN INDICATES A WOOD JOIST. SEE WOOD JOIST SCHEDULE FOR ADDITIONAL INFORMATION. H. P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. I. AT DRIVE THRU, TIE EACH ROOF TRUSS AT BEARING LOCATIONS WITH (1) H2.5A OR (1) H1 CLIP, AND EACH GIRDER TRUSS WITH (2) H2.5A CLIPS, UNO. J. AT MAIN BUILDING, TIE EACH ROOF TRUSS AT LOCATIONS WITH BEARING/UPLIFT CLIP BY TRUSS MANUFACTURER. USE 0.148"x3" NAILS. K. "D=" INDICATES DRAG LOAD (ASD) THAT TRUSS MANUFACTURER IS TO DESIGN TRUSS FOR IN BOTH TENSION AND COMPRESSION. L. TIE EACH ROOF JOIST AT BEARING LOCATIONS WITH (1) H2.5A CLIP, UNO. M. PROVIDE CONTINUOUS BEARING FOR ALL POSTS AND BUILT-UP STUDS TO THE FOUNDATION PER TYPICAL "SOLID BLOCKING BETWEEN FLOORS" DETAIL. N. FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING CONDITION. O. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. POST (P) SCHEDULE MARK SIZE SPECIES AND GRADE CONNECTION P1 (2) 2x6 DOUG FIR NO. 2 SEE TYPICAL DETAIL P2 4x6 DOUG FIR NO. 2 SEE TYPICAL DETAIL 6 4 3 1 2 ABDE 5 C AABBCC 3.5 4.8 1.5 D.1 C.1 B.1 14" RED-L BARREL OPEN-WEB WOOD TRUSSES AT 24" O.C. 14" RED-L BARREL OPEN-WEB WOOD TRUSSES AT 24" O.C. HSS8X6X1/4 HSS6X6X1/4 TYPICAL ROOF SHEATHING APA RATED ROOF SHEATHING W/ NAILS AT O.C. AT PANEL EDGES AND BOUNDARY AND AT O.C. IN THE FIELD. 19/32"8d 6" 12" 5 5 5 B1 B6 W18X46 (LOW) (HIGH) 5 B1 B1 B1 5 5 B6 B1 1 1 2 2 11 B1 B6 2 1 1 D= 3 6 0 0 # D= 2 2 0 0 # 3 WJ 3 4 5 203 S4.0 ________________________ 202 S4.0 ________________________ 225 S4.1 ________________________ 217 S4.1 ________________________ 201 S4.0 ________________________ 217 S4.1 ________________________217 S4.1 ________________________ 204 S4.0 ________________________ 6 223 S4.1 ________________________ 6 4 210 S4.0 ________________________ 218 S4.1 ________________________ 208 S4.0 ________________________ 216 S4.0 ________________________ SC1 216 S4.0 ________________________ SC1 212 S4.0 ________________________ 6 WJ 3 202 S4.0 ________________________ 211 S4.0 ________________________ 224 S4.1 ________________________ 30 P S F 0 P S F 4 219 S4.1 ________________________ 7 8 8 5 5 6. 5 5 5 9 10 N O TF O R C O N S T R U C T I O N P U R P O S E S PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : DBP 4/ 5 / 2 0 2 3 9 : 2 5 : 3 5 A M A u t o d e s k D o c s : / / 2 3 - 0 3 8 _ B e e h i v e F ed e r a l C r e d i t U n i o n R e x b u r g / I F 2 3 - 0 3 8 _ B e e h i v e F e d e r a l C r e d i t U n i o n R e x b u r g . r v t S2.2 23-038 BE E H I V E F C U -N O R T H R E X B U R G UP P E R R O O F F R A M I N G P L A N 02/23/2023 AV BEAM (B) SCHEDULE MARK SIZE B1 (2) 2x6 OR 4x6 OR (2) 1 3/4x 5 1/2 LVL B2 (2) 2x8 OR 4x8 OR (2) 1 3/4x5 1/2 LVL B3 (2) 1 3/4x9 1/2 LVL OR 3 1/2x9 1/2 LVL B4 5 1/8x12 GLB B5 (1) 1 3/4x9 1/2 LVL B6 2x6 B7 5 1/8x6 GLB B8 5 1/8x12 GLB KEYNOTES 1 INVERTED SIMPSON HUC26-2 HANGER 2 STRUCTURAL FASCIA, UNBROKEN FROM CORNER FOR 8'-0" MIN 3 4x BLOCKING BETWEEN EACH TRUSS W/ CONT CMSTC16 STRAP, SEE TYPICAL DETAIL. 4 ADD WOOD NAILER TO STEEL COLUMN PER "PLAN-STEEL COLUMN AT WOOD STUD WALL" TYPICAL DETAIL. 5 ALIGN DRAG TRUSS W/ COLUMN ON E4 6 OPENING FOR MECHANICAL DUCT, COORDINATE W/ ARCH AND MECHANICAL. 7 IN ADDITION TO BALANCED ROOF SNOW LOAD, TRUSS MANUFACTURER TO DESIGN TRUSSES FOR DRIFTING SNOW LOAD FOR LENGTH AND MAGNITUDE SHOWN, SEE TYPICAL DETAIL 8 DISCONTINUE NAILER AND THREADED STUDS AT OVERHANG 9 OPENING FOR MECHANICAL DUCT MUST NOT EXCEDED 10% OF SHEARWALL LENGTH, SEE TYPICAL DETAIL 10 BRACE NON-BEARING WALL PER "TYPICAL WOOD TRUSS AT NON-BEARING WALL" DETAIL ROOF FRAMING PLAN NOTES A. VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B. ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C. IF DOUBLE TOP PLATE IS NOTCHED, STEPPED OR BROKEN, PROVIDE A SIMPSON MSTC40 STRAP AT DISCONTINUITY. D. TYPICAL BEARING WALL FRAMING SHALL BE 2x6 STUDS AT 16" O.C. UNO. E. PROVIDE TRIMMER STUDS (TS) AND KING STUDS (KS) AT OPENINGS AS FOLLOWS, U.N.O.: OPENINGS 6'-0" OR LESS, (1) TS & (1) KS, OPENINGS 6'-1" TO 9'-0", (1) TS & (2) KS, 9'-1" TO 12-0", (2) TS & (3) KS. FOR ATTACHMENT, SEE "TYPICAL HEADER CONNECTION" DETAIL. F. B1, B2, ETC. - AS SHOWN ON PLAN INDICATES A BEAM OR HEADER. SEE BEAM SCHEDULE FOR ADDITIONAL INFORMATION. G. WJ1, WJ2, ETC. - AS SHOWN ON PLAN INDICATES A WOOD JOIST. SEE WOOD JOIST SCHEDULE FOR ADDITIONAL INFORMATION. H. P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. I. AT DRIVE THRU, TIE EACH ROOF TRUSS AT BEARING LOCATIONS WITH (1) H2.5A OR (1) H1 CLIP, AND EACH GIRDER TRUSS WITH (2) H2.5A CLIPS, UNO. J. AT MAIN BUILDING, TIE EACH ROOF TRUSS AT LOCATIONS WITH BEARING/UPLIFT CLIP BY TRUSS MANUFACTURER. USE 0.148"x3" NAILS. K. "D=" INDICATES DRAG LOAD (ASD) THAT TRUSS MANUFACTURER IS TO DESIGN TRUSS FOR IN BOTH TENSION AND COMPRESSION. L. TIE EACH ROOF JOIST AT BEARING LOCATIONS WITH (1) H2.5A CLIP, UNO. M. PROVIDE CONTINUOUS BEARING FOR ALL POSTS AND BUILT-UP STUDS TO THE FOUNDATION PER TYPICAL "SOLID BLOCKING BETWEEN FLOORS" DETAIL. N. FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING CONDITION. O. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. NOTES: SHEARWALL TYPE SCHEDULE MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 5 7/16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 6. 7/16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 4" O.C. 8d COMMON AT 12" O.C. CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 24" O.C. CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 32" O.C. WOOD: 16d STAGGERED AT 4" O.C. SCALE: 1/4" = 1'-0" UPPER ROOF FRAMING PLAN WOOD JOIST (WJ) SCHEDULE MARK WOOD JOIST JOIST SPACING (O.C.) FACE MOUNT HANGER TOP FLANGE HANGER WJ1 9 1/2" TJI 110 2'-0" LSSR1.81Z WJ2 14" TJI 110 2'-0" WJ3 2x6 2'-0" LUS26 LB26 NORTH STEEL COLUMN (SC) SCHEDULE MARK SIZE BASE CONNECTION SC1 HSS4x4x1/4 PER DETAIL, SEE PLAN SC2 HSS5x5x1/4 3/4"x11"x11" PLATE W/ (4) 3/4" DIA ANCHOR BOLTS W/ 8" MIN EMBEDMENT, U.N.O. SC3 HSS6x6x1/4 PER DETAIL, SEE PLAN SC4 HSS6x6x5/8 3/4"x12"x12" PLATE W/ (4) 3/4" DIA ANCHOR BOLTS W/ 8" MIN EMBEDMENT, U.N.O. KEYNOTES: NOTES: 3" CLR 3" CL R 8 10 7 9 6 5 4 1 2 3 8" MI N 1. WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ ANCHOR BOLTS PER SHEARWALL SCHEDULE 3. CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5. CONCRETE FOOTING, SEE PLAN 6. COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.MINIMUM FOOTING DEPTH, SEE GSN 8.FINISH GRADE PER ARCH 9. EDGE NAILING, SEE SHEARWALL SCHEDULE 10. WALL SHEATHING AS OCCURS, SEE PLAN 11.MASONRY VENEER PER ARCH A.ALL WOOD WITHIN 8" OF FINISH GRADE SHALL BE PRESERVATIVE TREATED LUMBER (INCLUDING SHEATHING) AND BE WATERPROOFED PER ARCHITECTURAL REQUIREMENTS, SEE ARCH DRAWINGS 11 KEYNOTES: NOTES: 3" CLR 3" CL R 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ ANCHOR BOLTS PER SHEARWALL SCHEDULE 3.CONCRETE SLAB ON GRADE, SEE PLAN 4. CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7. MINIMUM FOOTING DEPTH, SEE GSN 8. FINISH GRADE PER ARCH 9.EDGE NAILING, SEE SHEARWALL SCHEDULE 10.WALL SHEATHING AS OCCURS, SEE PLAN 11.MASONRY VENEER PER ARCH 12. BRICK VENEER PER ARCH, ATTACH PER GSN 13. WALL SHEATHING ON INTERIOR SIDE WALL WHERE OCCURS PER ARCH 8 10 7 9 6 1 2 5 4 3 12 11 9 13 A.ALL WOOD WITHIN 8" OF FINISH GRADE SHALL BE PRESERVATIVE TREATED LUMBER (INCLUDING SHEATHING) AND BE WATERPROOFED PER ARCHITECTURAL REQUIREMENTS, SEE ARCH DRAWINGS 8" MI N KEYNOTES: NOTES: 3" CLR 3" CL R 8 7 6 8 5 4 3 1 2 1.WALL BEYOND, SEE PLAN 2. #4 BENT DOWEL AT 18" O.C. 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7. MINIMUM FOOTING DEPTH, SEE GSN 8.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 18" 18" A. ALL WOOD WITHIN 8" OF FINISH GRADE SHALL BE PRESERVATIVE TREATED LUMBER (INCLUDING SHEATHING) AND BE WATERPROOFED PER ARCHITECTURAL REQUIREMENTS, SEE ARCH DRAWINGS PLANA A KEYNOTES: 1. STEEL COLUMN, SEE PLAN 2. STEEL BASE PLATE W/ LEVELING NUTS, SEE COLUMN SCHEDULE 3. ±1 1/2" NON-SHRINK GROUT 4.CONCRETE CLOSURE POUR. POUR AFTER DEAD LOADS ARE IN PLACE 5. CONCRETE SLAB ON GRADE, SEE PLAN 6. CONCRETE FOOTING, SEE PLAN 7. COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 1/4 3" CLR 3" CL R 11_2" TY P 11_2" TY P 11_ 2" TYP 1 6 7 3 5 1 2 2 2 1 4 4 KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ ANCHOR BOLTS PER SHEARWALL SCHEDULE 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE FOOTING, SEE PLAN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 6.EDGE NAILING, SEE SHEARWALL SCHEDULE 7.WALL SHEATHING AS OCCURS, SEE PLAN 8.#4 BENT DOWEL AT 18" O.C. 7 6 5 1 2 4 3 3" CLR 3" CL R 31_2"MI N 12" 12" 8 KEYNOTES: 3" CLR 3" CL R 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ O.145"∅ MIN SHOT PIN AT 32" O.C. 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE FOOTING, SEE PLAN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 5 1 2 4 3 PLAN PLAN B B A A KEYNOTES: 1/4 1. STEEL COLUMN, SEE PLAN 2. 1"x12"x12" STEEL BASE PLATE W/ (4) 7/8" DIA HEAVY HEX BOLTS W/ LEVELING NUTS W/ 10" MIN EMBEDMENT 3. ±1 1/2" NON-SHRINK GROUT 4.20" SQR CONCRETE PIER W/ (12) #5 HOOKED DOWELS 5. FLATWORK PER ARCH/CIVIL 6. CONCRETE FOOTING, SEE PLAN 7. COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 8. BRICK VENEER PER ARCH 9. 15" SQR CONCRETE PIER W/ (8) VERTICAL DOWELS 10.(3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 1/4 1/4 3" CLR 3" CL R 3' - 0 " M A X 1' - 0 " 11_ 2" CLR 2' - 0 " M I N 1 1_2" CL R 1 1_2" CL R 11_2" TY P 11_2" TY P 11_ 2" TYP 2 1_ 2" TYP 1 6 7 3 5 2 4 1 9 5 8 4 10 10 9 1 2 GRID GRID KEYNOTES: 1/4 1 2 1. STEEL COLUMN, SEE PLAN 2. 1/2"x8 1/2"x8 1/2" THICK STEEL BASE PLATE OVER ±1 1/2" NON-SHRINK GROUT W/ (3) 3/4" DIA ANCHOR BOLTS W/ LEVELING NUTS W/ 8" MIN EMBEDMENT 3. CONCRETE WALL, SEE PLAN 4.(2) #4 BENT BAR W/ STANDARD HOOK AT BASE EACH SIDE OF COLUMN. EXTEND TO BOTTOM OF FOOTING 71_4" 5" 3" TYP 11_ 2" TYP 3 1_ 4"1_4" 4 3 11_ 2" TYP KEYNOTES: 11_2" TY P 2" TY P 11_ 2" TYP 81_2" 1/4 1 3 2 1. STEEL COLUMN, SEE PLAN 2.1/2"x6"x11" THICK STEEL BASE PLATE OVER ±1 1/2" NON-SHRINK GROUT W/ (4) 3/4" DIA ANCHOR BOLTS W/ LEVELING NUTS W/ 8" MIN EMBEDMENT 3.CONCRETE WALL, SEE PLAN PLANA A KEYNOTES: 1/4 3" CLR 3" CL R 11_2" T Y P 11_2" T Y P 11_ 2" TYP 11_ 2" TYP 1. STEEL COLUMN, SEE PLAN 2. 1/2"x6"x11" THICK STEEL BASE PLATE W/ (4) 3/4" DIA ANCHOR BOLTS W/ LEVELING NUTS W/ 8" MIN EMBEDMENT 3. MASONRY VENEER PER ARCH, ATTACH PER GSN 4. ±1 1/2" NON-SHRINK GROUT 5.CONCRETE WALL, SEE PLAN 6.(2) #4 BENT BAR W/ STANDARD HOOK AT BASE EACH SIDE OF COLUMN. EXTEND TO BOTTOM OF FOOTING 7. CONCRETE FOOTING, SEE PLAN 8.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 9.MINIMUM FOOTING DEPTH, SEE PLAN 10. FINISH GRADE PER ARCH 11. CONCRETE SLAB ON GRADE, SEE PLAN 12.BRICK VENEER PER ARCH, ATTACH PER GSN 10 9 8 7 5 11 12 3 1 2 3 6 1 2 4 6 8" MI N PLANA A KEYNOTES: 10"6" 8" 8" 1/4 3" CLR 3" CL R 11_2" T Y P 11_2" T Y P 11_ 2" TYP 11_ 2" TYP 1.STEEL COLUMN, SEE PLAN 2.1/2"x6"x11" THICK STEEL BASE PLATE OVER ±1 1/2" NON-SHRINK GROUT W/ (4) 3/4" DIA ANCHOR BOLTS W/ LEVELING NUTS W/ 8" MIN EMBEDMENT 3.MASONRY VENEER PER ARCH, ATTACH PER GSN 4.CONCRETE PEDESTAL 5.CONCRETE WALL, SEE PLAN 6. (2) #4 BENT BAR W/ STANDARD HOOK AT BASE EACH SIDE OF COLUMN. EXTEND TO BOTTOM OF FOOTING AS SHOWN 7.CONCRETE FOOTING, SEE PLAN 8.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 9. MINIMUM FOOTING DEPTH, SEE PLAN 10.FINISH GRADE PER ARCH 11.CONCRETE SLAB ON GRADE, SEE PLAN 12. BRICK VENEER PER ARCH, ATTACH PER GSN 10 9 8 7 5 11 12 3 1 2 6 1 2 4 6 5 8" MI N N O TF O R C O N S T R U C T I O N P U R P O S E S PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : DBP 4/ 5 / 2 0 2 3 9 : 2 5 : 3 5 A M A u t o d e s k D o c s : / / 2 3 - 0 3 8 _ B e e h i v e F ed e r a l C r e d i t U n i o n R e x b u r g / I F 2 3 - 0 3 8 _ B e e h i v e F e d e r a l C r e d i t U n i o n R e x b u r g . r v t S3.0 23-038 BE E H I V E F C U -N O R T H R E X B U R G FO U N D A T I O N D E T A I L S 02/23/2023 AV SCALE: NTS101WOOD STUD WALL AT FOUNDATION SCALE: NTS102WOOD STUD WALL AT FOUNDATION SCALE: NTS103CONCRETE SLAB AT FOUNDATION SCALE: NTS106STEEL COLUMN AT FOUNDATION SCALE: NTS104WOOD STUD WALL AT FOUNDATION SCALE: NTS105WOOD STUD WALL AT FOUNDATION SCALE: NTS107STEEL COLUMN AT FOUNDATION SCALE: NTS108STEEL COLUMN AT FOUNDATION SCALE: NTS109STEEL COLUMN AT FOUNDATION SCALE: NTS110STEEL COLUMN AT FOUNDATION SCALE: NTS111STEEL COLUMN AT FOUNDATION GRID GRID KEYNOTES: 1/4 1.STEEL COLUMN, SEE PLAN 2. 1/2"x6"x11" STEEL BASE PLATE OVER ±1 1/2" NON-SHRINK GROUT W/ (4) 3/4" DIA ANCHOR BOLTS W/ LEVELING NUTS W/ 8" MIN EMBEDMENT 3.CONCRETE WALL, SEE PLAN 31_2" 11_2" T Y P 11_ 2" TYP 5"81_ 2" 21_2" 51_2" 31_ 2" 41_2" 3 1 2 11_2" T Y P GRID GR I D KEYNOTES: 1/4 1 2 1. STEEL COLUMN, SEE PLAN 2. 1/2"x8 1/2"x8 1/2" THICK STEEL BASE PLATE OVER ±1 1/2" NON-SHRINK GROUT W/ (4) 3/4" DIA ANCHOR BOLTS W/ LEVELING NUTS W/ 8" MIN EMBEDMENT 3. CONCRETE WALL, SEE PLAN 4.(2) #4 BENT BAR W/ STANDARD HOOK AT BASE EACH SIDE OF COLUMN. EXTEND TO BOTTOM OF FOOTING 10" 6" 51_ 4" 71_4" 3" T Y P 11_2" T Y P 3 1_4" 1_ 4" 4 3 23_ 4" GRID GRID KEYNOTES: 8"9" 6" 5" 1' - 1 " 31_4" 11_2" TY P 11_2" TY P 11_ 2" TYP3" TYP 1/4 1. STEEL COLUMN, SEE PLAN 2.1/2"x6"x11" THICK STEEL BASE PLATE OVER ±1 1/2" NON-SHRINK GROUT W/ (4) 3/4" DIA ANCHOR BOLTS W/ LEVELING NUTS W/ 8" MIN EMBEDMENT 3. CONCRETE SLAB ON GRADE, SEE PLAN 4.(2) #4 BENT BAR W/ STANDARD HOOK AT BASE EACH SIDE OF COLUMN. EXTEND TO BOTTOM OF FOOTING AS SHOWN 5.CONCRETE WALL, SEE PLAN 1 4 5 5 2 4" 13_4" N O TF O R C O N S T R U C T I O N P U R P O S E S PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : DBP 4/ 5 / 2 0 2 3 9 : 2 5 : 3 5 A M A u t o d e s k D o c s : / / 2 3 - 0 3 8 _ B e e h i v e F ed e r a l C r e d i t U n i o n R e x b u r g / I F 2 3 - 0 3 8 _ B e e h i v e F e d e r a l C r e d i t U n i o n R e x b u r g . r v t S3.1 23-038 BE E H I V E F C U -N O R T H R E X B U R G FO U N D A T I O N D E T A I L S 02/23/2023 AV SCALE: NTS113STEEL COLUMN AT FOUNDATION SCALE: NTS114STEEL COLUMN AT FOUNDATION SCALE: NTS112STEEL COLUMN AT FOUNDATION KEYNOTES: NOTES: 3 4 5 1. WOOD TRUSS W/ CLIP, SEE PLAN 2.STEEL BEAM, SEE PLAN 3.CONT BEVELED 4x NAILER W/ 5/8" DIA THREADED STUDS W/ WASHER AT 32" O.C. (COUNTER SINK AS REQUIRED) 4.ROOF SHEATHING, SEE PLAN 5.BOUNDARY NAILING, SEE PLAN 6.2x BLOCKING W/ A35 CLIP BETWEEN EACH TRUSS 7.WINDOW SYSTEM, SEE ARCH 8. CONT 4x NAILER W/ 5/8" DIA THREADED STUDS W/ WASHER AT 32" O.C. (COUNTER SINK AS REQUIRED). DISCONTINUE NAILER AND THREADED STUDS AT OVERHANG 10. SOFFIT PER ARCH A.COORDINATE ROOF VENTILATION B.FASCIA PER ARCHITECTURAL DETAILS 1 6 2 8 7 3_4" 10 KEYNOTES: NOTES: 3 5 4 7 8 6 910 1. WOOD TRUSS, SEE PLAN 2.BRICK VENEER PER ARCH, ATTACH PER GSN 3.WOOD JOIST W/ CLIP AND HANGER, SEE PLAN 4.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 5.WOOD STUD WALL, SEE PLAN 6. WALL SHEATHING AS OCCURS, SEE PLAN 7.EDGE NAILING, SEE SHEARWALL SCHEDULE 8. 2x BLOCKING W/ A35 CLIP BETWEEN EACH JOIST 9. ROOF SHEATHING, SEE PLAN 10.BOUNDARY NAILING, SEE PLAN 11.SOFFIT PER ARCH A. COORDINATE ROOF VENTILATION B.FASCIA PER ARCHITECTURAL DETAILS 1 2'-0" MAX 2 11 KEYNOTES: 1.WOOD TRUSS, SEE PLAN 2. 2x4x8'-0" LONG AT 6'-0" O.C. W/ (2) 16d NAILS AT EACH TRUSS 3.BOUNDARY NAILING, SEE PLAN 4.ROOF SHEATHING, SEE PLAN 1 43 2'-0" MAX 2 3 KEYNOTES: NOTES: 1.WOOD TRUSS, SEE PLAN 2. BRICK VENEER PER ARCH, ATTACH PER GSN 3. CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 4. ROOF SHEATHING, SEE PLAN 5.BOUNDARY NAILING, SEE PLAN 6.WALL SHEATHING AS OCCURS, SEE PLAN 7. EDGE NAILING, SEE SHEARWALL SCHEDULE 8.WOOD STUD WALL, SEE PLAN 9. SOFFIT PER ARCH 1 45 7 6 8 2 3 A. COORDINATE ROOF VENTILATION B.FASCIA PER ARCHITECTURAL DETAILS 9 5 KEYNOTES: NOTES: 1 2 3 5 4 7 8 6 9 10 1.WOOD JOIST W/ CLIP, SEE PLAN 2. CONT SHAPED BLOCK W/ 16d NAILS AT 6" O.C. 3.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 4. WOOD STUD WALL, SEE PLAN 5.WALL SHEATHING AS OCCURS, SEE PLAN 6.EDGE NAILING, SEE SHEARWALL SCHEDULE 7.(4) 16d NAILS IN BOTTOM FLANGE OF EACH JOIST 8.JOIST BLOCKING W/ (4) 16d NAILS BETWEEN EACH JOIST 9.ROOF SHEATHING, SEE PLAN 10.BOUNDARY NAILING, SEE PLAN 11. WEB STIFFENER PER TYPICAL DETAIL 12.BRICK VENEER PER ARCH, ATTACH PER GSN 13.SOFFIT PER ARCH A.COORDINATE ROOF VENTILATION B.FASCIA PER ARCHITECTURAL DETAILS 3_4" 12 11 13 KEYNOTES: NOTES: 1 2 3 5 4 7 8 6 910 1. WOOD JOIST, SEE PLAN 2.WOOD BEAM, SEE PLAN 3.WOOD JOIST W/ CLIP AND HANGER, SEE PLAN 4.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 5. WOOD STUD WALL, SEE PLAN 6.WALL SHEATHING AS OCCURS, SEE PLAN 7.EDGE NAILING, SEE SHEARWALL SCHEDULE 8.2x BLOCKING W/ A35 CLIP BETWEEN EACH JOIST 9.ROOF SHEATHING, SEE PLAN 10.BOUNDARY NAILING, SEE PLAN 11. BRICK VENEER PER ARCH, ATTACH PER GSN 12. HORIZONTAL STRAP AS OCCURS, SEE PLAN 13.SOFFIT PER ARCH A. COORDINATE ROOF VENTILATION B.FASCIA PER ARCHITECTURAL DETAILS 2'-0" MAX 12 11 13 10 KEYNOTES: 1.WOOD JOIST, SEE PLAN 2. CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3. WOOD STUD WALL, SEE PLAN 4.WALL SHEATHING AS OCCURS, SEE PLAN 5. EDGE NAILING, SEE SHEARWALL SCHEDULE 6.ALIGN CONT JOIST W/ STUD WALL W/ 16d NAILS AT 4" O.C. 7.ROOF SHEATHING, SEE PLAN 8. BOUNDARY NAILING, SEE PLAN 9.WOOD JOIST BLOCKING AT 24" O.C. W/ (2) 16d NAILS 1 3 2 5 6 4 78 9 KEYNOTES: NOTES: 1.WOOD TRUSS W/ CLIP, SEE PLAN 2. STEEL BEAM, SEE PLAN 3.CONT BEVELED 4X NAILER W/ 5/8" DIA THREADED STUDS W/ WASHER AT 32" O.C. (COUNTER SINK AS REQUIRED) 4.ROOF SHEATHING, SEE PLAN 5. BOUNDARY NAILING, SEE PLAN 6.2x BLOCKING W/ A35 CLIP BETWEEN EACH TRUSS 7.2x BLOCKING BETWEEN EACH TRUSS W/ 16d NAILS AT 6" O.C. 8. WINDOW SYSTEM, SEE ARCH 9.CONT 4X NAILER W/ 5/8" DIA THREADED STUDS W/ WASHER AT 32" O.C. (COUNTER SINK AS REQUIRED) 10.SOFFIT PER ARCH A. COORDINATE ROOF VENTILATION B.FASCIA PER ARCHITECTURAL DETAILS 1 2 3456 8 9 12 3 4 5 7 31_2" 31_2" 10 KEYNOTES: NOTES: 1.WOOD TRUSS W/ CLIP, SEE PLAN 2. WOOD STUD WALL, SEE PLAN 3.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 4.CONT BEVELED 4x W/ (1) 1/4" DIA x6" LONG SDS SCREW AT 24" O.C. 5.ROOF SHEATHING, SEE PLAN 6.BOUNDARY NAILING, SEE PLAN 7. 2x BLOCKING BETWEEN EACH TRUSS W/ 16d NAILS AT 6" O.C. 8.WALL SHEATHING AS OCCURS, SEE PLAN 9. EDGE NAILING, SEE SHEARWALL SCHEDULE A. COORDINATE ROOF VENTILATION B.FASCIA PER ARCHITECTURAL DETAILS 31_2" 1 1 2 9 3 4 5 6 7 8 KEYNOTES: NOTES: 1.WOOD TRUSS W/ CLIP, SEE PLAN 2. WOOD STUD WALL, SEE PLAN 3. CONT 2x DBL TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 4.CONT BEVELED 2x6 W/ (1) 1/4" DIA x 2 1/2" LONG SDS SCREW AT 24" O.C. 5. ROOF SHEATHING, SEE PLAN 6.BOUNDARY NAILING, SEE PLAN 7.2x BLOCKING W/ A35 CLIP BETWEEN EACH TRUSS 8.2x BLOCKING BETWEEN EACH TRUSS W/ 16d NAILS AT 6" O.C. 9.WALL SHEATHING AS OCCURS, SEE PLAN 10.EDGE NAILING, SEE SHEARWALL SCHEDULE 11.CONT 2x BOTTOM PLATE W/ ATTACHMENT, SEE SHEARWALL SCHEDULE 12. NO SHEATHING SPLICE TO OCCUR IN THIS AREA (2'-0" ABOVE OR BELOW LOWER WALL TOP PLATE) 13.SOFFIT PER ARCH A.COORDINATE ROOF VENTILATION B. FASCIA PER ARCHITECTURAL DETAILS 1 3 4567 2 9 1 3 5 6 8 11_2" 11_2" 10 10 11 412 10 13 9 2 KEYNOTES: 1.WOOD TRUSS W/ CLIP, SEE PLAN 2. WOOD STUD WALL, SEE PLAN 3. CONT 2x DBL TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 4.CONT BEVELED 4x W/ (1) 1/4" DIA x 6" LONG SDS SCREW AT 24" O.C. 5.ROOF SHEATHING, SEE PLAN 6.2x BLOCKING W/ A35 CLIP BETWEEN EACH TRUSS 7.BOUNDARY NAILING, SEE PLAN 8.WALL SHEATHING AS OCCURS, SEE PLAN 9. EDGE NAILING, SEE SHEARWALL SCHEDULE 10. WOOD JOIST W/ HANGER, SEE PLAN 11.WEB STIFFENER PER TYPICAL DETAIL 12.1 3/4"x11 7/8" LVL LEDGER W/ (3) SDWS22600DB SCREWS AT 16" O.C. 13.SOFFIT PER ARCH 1 3 4 5 7 6 2 8 10 5 31_2" 9 12 4" 4" 11 7 13 KEYNOTES: NOTES: 1. WOOD TRUSS W/ CLIP, SEE PLAN 2.WOOD STUD WALL, SEE PLAN 3.CONT 2x DBL TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 4.CONT BEVELED 4x W/ (1) 1/4"∅x6" LONG SDS SCREW AT 24" O.C. 5.ROOF SHEATHING, SEE PLAN 6. 2x BLOCKING W/ A35 CLIP BETWEEN EACH TRUSS 7.BOUNDARY NAILING, SEE PLAN 8. WALL SHEATHING AS OCCURS, SEE PLAN 9.EDGE NAILING, SEE SHEARWALL SCHEDULE 10.WOOD JOIST W/ HANGER, SEE PLAN 11.WEB STIFFENER PER TYPICAL DETAIL 12. 2x6 BLOCKING W/ (3) 16d NAILS BETWEEN EACH JOIST 13. CONT 2x BOTTOM PLATE W/ ATTACHMENT, SEE SHEARWALL SCHEDULE14.WOOD BEAM, SEE PLAN 15. SOFFIT PER ARCH 1 3 4 5 7 6 2 8 10 5 31_2" 9 14 11 7 13 12 15 A.COORDINATE ROOF VENTILATION B.FASCIA PER ARCHITECTURAL DETAILS PLANA A KEYNOTES: 3/16 TYP 3/16 3/16 (3) SIDES TYP 3/16 3/16 1. STEEL COLUMN, SEE PLAN 2. STEEL BEAM, SEE PLAN 3.3/16" x 4" x 0'-5" STEEL PLATE AT EACH SIDE OF COLUMN 4.L2x2x3/16x0'-4" STEEL ANGLE TOP AND BOTTOM 1 2 1 2 1_ 2" GAP 3 44 3 3 4 SECTIONA A KEYNOTES: 1/4 1/4 1/4 1/4 TYP TYP 1/4 1/4 1/4 1/4 1 WEST FACE 1.STEEL COLUMN, SEE PLAN 2. WOOD BEAM, SEE PLAN. SHAVE WEST FACE AT STEEL PLATE 3.3/8" x 6" x 1'-0" STEEL PLATE 4.1/2" x 3" x 0'-6" STEEL PLATE 5. 1/4" x 4" x 0'-11" STEEL PLATE W/ (2) 1/4" DIA x 2 1/2" LONG SDS SCREWS EACH FACE. ALIGN WEST PLATE W/ COLUMN FACE6.1 1/2" LONG SLOTTED HOLE 1 24 3 2 2" 4" 11_ 2" 5 6 2 4 5 3 SECTIONA A KEYNOTES: 1/4 1/4 1/4 1/4TYP 1/4 1/4 1/4 1/4 1WEST FACE 1.STEEL COLUMN, SEE PLAN 2. WOOD BEAM, SEE PLAN. SHAVE WEST FACE AT STEEL PLATE 3.3/8" x 6" x 1'-0" STEEL PLATE, WEST TO ALIGN W/ COLUMN FACE 4.1/2" x 3" x 0'-6" STEEL PLATE 5.1/4" x 4" x 0'-11" STEEL PLATE W/ (2) 1/4" DIA x 2 1/2" LONG SDS SCREWS EACH FACE. ALIGN WEST PLATE W/ COLUMN FACE6.1 1/2" LONG SLOTTED HOLE 1 24 3 5 6 2 4 5 3 2" 4" 11_ 2" 1" KEYNOTES: NOTES: 3/16 3/16 3/16 3/16 1.STEEL COLUMN, SEE PLAN 2. STEEL BEAM, SEE PLAN 3.1/4" THICK STEEL WEB STIFFENER, EACH SIDE OF BEAM 3 2 2 1 A.SEE CORRESPONDING DETAILS FOR ADDITIONAL INFORMATION N O TF O R C O N S T R U C T I O N P U R P O S E S PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : DBP 4/ 5 / 2 0 2 3 9 : 2 5 : 3 5 A M A u t o d e s k D o c s : / / 2 3 - 0 3 8 _ B e e h i v e F ed e r a l C r e d i t U n i o n R e x b u r g / I F 2 3 - 0 3 8 _ B e e h i v e F e d e r a l C r e d i t U n i o n R e x b u r g . r v t S4.0 23-038 BE E H I V E F C U -N O R T H R E X B U R G RO O F F R A M I N G D E T A I L S 02/23/2023 AV SCALE: NTS201WOOD TRUSS AT STEEL BEAM SCALE: NTS202WOOD TRUSS AT WOOD STUD WALL SCALE: NTS203WOOD TRUSS AT WINDOW SYSTEM SCALE: NTS204WOOD TRUSS AT WOOD STUD WALL SCALE: NTS205WOOD JOIST AT WOOD STUD WALL SCALE: NTS206WOOD JOIST AT WOOD STUD WALL SCALE: NTS207WOOD JOIST AT WOOD STUD WALL SCALE: NTS208WOOD TRUSS AT STEEL BEAM SCALE: NTS209WOOD TRUSS AT WOOD STUD WALL SCALE: NTS210WOOD TRUSS AT WOOD STUD WALL SCALE: NTS211WOOD TRUSS AND WOOD JOIST AT WOOD STUD WALL SCALE: NTS212WOOD TRUSS AND WOOD JOIST AT WOOD BEAM SCALE: NTS213STEEL BEAM AT STEEL COLUMN SCALE: NTS214WOOD BEAMS AT STEEL COLUMN SCALE: NTS215WOOD BEAM AT STEEL COLUMN SCALE: NTS216STEEL BEAM AT STEEL COLUMN KEYNOTES: 3/16 3/16 3/16 1. STEEL COLUMN, SEE PLAN 2.STEEL BEAM, SEE PLAN 3.1/2" x 6" x 0'-6" STEEL CAP PLATE 2 1 3 KEYNOTES: 3/16 3/16 3/16 3/16 2 3/16 2 5/16 5/16 1. STEEL COLUMN W/ 1" DIA HOLES AT ROD, SEE PLAN 2. STEEL BEAM, SEE PLAN 3.SIMPSON HDU2 W/ 5/8" DIA ROD EXTENDED INTO STEEL BEAM'S WEB 6" MIN 4. 3/8" x 3 1/2" x 0'-9" STEEL PLATE W/ (3) 3/4" DIA A325 BOLTS 5. WOOD STUD WALL, SEE PLAN 6. CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 7.2x NAILER, SEE PLAN KEYNOTES 8.1/2" x 6" x 0'-6" STEEL CAP PLATE 2 1 2'-6" MAX 8 2 4 6" 11_2" 3" 3" 1" 1 2"11_ 2"6 5 7 3 4 5__16 " KEYNOTES: NOTES: 1.WOOD BEAM, SEE PLAN 2. WINDOW SYSTEM, SEE ARCH 3.CONT BEVELED 4x W/ (1) 1/4" DIA x 6" LONG SDS SCREW AT 24" O.C. 4.ROOF SHEATHING, SEE PLAN 5.BOUNDARY NAILING, SEE PLAN 6. 2x BLOCKING W/ A35 CLIP BETWEEN EACH JOIST 7. WOOD JOIST W/ CLIP AND HANGER, SEE PLAN 8.SOFFIT PER ARCH 1 7 2 1 3 6 5 4 8 3_4" A.COORDINATE ROOF VENTILATION B. FASCIA PER ARCHITECTURAL DETAILS KEYNOTES: NOTES: 1. STEEL BEAM, SEE PLAN 2.WOOD STUD WALL, SEE PLAN 3.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 4. WALL SHEATHING AS OCCURS, SEE PLAN 5.EDGE NAILING, SEE SHEARWALL SCHEDULE 6.BRICK VENEER PER ARCH, ATTACH PER GSN 7.WOOD JOIST W/ CLIP AND HANGER, SEE PLAN 8.ROOF SHEATHING, SEE PLAN 9. BOUNDARY NAILING, SEE PLAN 10. 2x BLOCKING W/ A35 CLIP BETWEEN EACH JOIST 11. CONT DBL 2x NAILER W/ 5/8" DIA THREADED STUDS W/ WASHER AT 32" O.C. (COUNTER SINK AS REQUIRED) 12.L6" x 4" x 5/16" (LLV) STEEL GALVANIZED ANGLE W/ (2) 1/4" DIA x 4 1/2" LONG STAINLESS SDS SCREWS AT EACH STUD, CURVE AS REQUIRED 13. SOFFIT PER ARCH 14. WALL SHEATHING ON INTERIOR SIDE WALL WHERE OCCURS PER ARCH A. COORDINATE ROOF VENTILATION B.FASCIA PER ARCHITECTURAL DETAILS 1 7 2 3 5 10 4 89 2'-0" MAX 6 13 11_2" 3" 2 12 6 4 11 13 9 14 5 SECTIONA A KEYNOTES: 1/4 1/41/4 1/4 1/4 1/4 1. STEEL COLUMN, SEE PLAN 2.STEEL BEAM, SEE PLAN 3. 3/8" x 3 1/2" x 0'-6" STEEL PLATE W/ (2) 3/4" DIA A325 BOLTS 4. WOOD BEAM, SEE PLAN 5.3/8" x 6" x 0'-6" STEEL PLATE 6.1/2" x 3" x 0'-6" STEEL PLATE 7.1/4" x 4" x 0'-5" STEEL PLATE W/ 1/4" DIA x 2 1/2" LONG SDS SCREW EACH FACE 8.1 1/2" LONG SLOTTED HOLE 1 46 5 7 8 2" 11_ 2" 1 3 2 11_2" 3" 11_ 2" 2" 4 KEYNOTES: NOTES: 1. WOOD TRUSS, SEE PLAN 2.BRICK VENEER PER ARCH, ATTACH PER GSN 3.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 4.ROOF SHEATHING, SEE PLAN 5.BOUNDARY NAILING, SEE PLAN 6. WALL SHEATHING AS OCCURS, SEE PLAN 7.EDGE NAILING, SEE SHEARWALL SCHEDULE 8. WOOD STUD WALL, SEE PLAN 9.SOFFIT PER ARCH 1 45 2'-0" MAX 7 6 8 2 3 A.COORDINATE ROOF VENTILATION B.FASCIA PER ARCHITECTURAL DETAILS 9 5 KEYNOTES: 1.STEEL COLUMN, SEE PLAN 2. 1/4" x 5 1/2" x 0'-11" STEEL CAP PLATE W/ (2) 1/4" DIA x 3" LONG SDS SCREWS 3. CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL. MATCH CURVATURE OF TRUSS. 4. WOOD STUD WALL, SEE PLAN 5.2x NAILER, SEE PLAN KEYNOTES 6.WOOD JOIST, SEE PLAN 7.ROOF SHEATHING, SEE PLAN 8. BOUNDARY NAILING, SEE PLAN 9.SIMPSON A35 CLIPS 7 1 1_ 2 " 6 8 3 9 9 6 8 2 1 4 5 5 SECTION PLAN A A B B KEYNOTES: NOTES: 1/4 TYP 1/4 3/16 3/16 3/16 1/4 1/4 1/4 1/4 3 1/4 3 1. STEEL COLUMN, SEE PLAN 2.STEEL BEAM, SEE PLAN 3.ROOF SHEATHING, SEE PLAN 4. 3/8" x 4" x 0'-9" STEEL PLATE W/ (3) 3/4" DIA A325 BOLTS 5. CONT BEVELED 4x W/ 5/8" DIA THREADED STUDS W/ WASHER AT 32" O.C. (COUNTER SINK AS REQUIRED) 6. WOOD TRUSS, SEE PLAN 7.WOOD DRAG TRUSS W/ 3 1/2" x 3 1/2" x AREA REQUIRED SHEAR BLOCK PER TRUSS MANUFACTURER 8.3/8" x 8" x AREA REQUIRED STEEL PLATE AT EACH SIDE OF TRUSS W/ (2) 1/4" DIA x 2 1/2" LONG SDS SCREWS. STAGGER SCREWS ON FAR SIDE AS SHOWN. COORDINATE DIMENSIONS AND SCREWS LOCATIONS W/ TRUSS MANUFACTURER 9.1/2" x 7" x 0'-10" STEEL PLATE 10.MC6x16.3 x AREA REQUIRED W/ (4) 1/4" DIA x 2 1/2" LONG SDS SCREWS. COORDINATE DIMENSIONS AND SCREWS LOCATIONS W/ TRUSS MANUFACTURER 11.1/2" x 6" x 0'-6" STEEL CAP PLATE 12. CONT SOLID BLOCKING W/ 5/8" DIA THRU BOLTS 13.L4x4x3/8 x LONGEST LENGTH POSSIBLE TO FIT BETWEEN TRUSS WEBS A.COORDINATE ROOF VENTILATION B. FASCIA PER ARCHITECTURAL DETAILS 7 2 53 1 2 7 2 5 3 31_2" 31_2" 9 104 8 11 FIELD MEASURE FIELD MEASURE 2 2 1 4 11 7 6 3 11_ 2" 2 1_ 2" 6" 11_2" 3" 3" 1" GAP C.L. COL TO F.O. TRUSS 6 1_ 2" 6 73 5 12 13 10 9 10 31_ 2" 1 9 5 7 SECTION DETAIL OF PLATE A A KEYNOTES: 3/16 1/4 3/16 3/16 1.STEEL COLUMN, SEE PLAN 2. SIMPSON HDU5 W/ 5/8" DIA ROD 3.3/8" x 3 1/2" x 0'-9" STEEL PLATE W/ (3) 3/4" DIA A325 BOLTS 4.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 5.2x NAILER, SEE PLAN KEYNOTES 6.CONT STRAP W/ NAILING, SEE PLAN KEYNOTES 7.NAIL IN EVERY HOLE IN STRAP 8. 4x BLOCKING BETWEEN EACH TRUSS 9.WOOD TRUSS, SEE PLAN 10.ROOF SHEATHING, SEE PLAN 11. BOUNDARY NAILING, SEE PLAN 12. 1/4" x 7" x 0'-7" STEEL CAP PLATE 13.1/4" x 3" x 1'-0" STEEL PLATE AT EACH FACE W/ (4) 1/4" DIA x 2 1/2" LONG SDS SCREWS STAGGERED 14.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL. MATCH CURVATURE OF TRUSS. 1 12 4 3 5 2 4 5__16 " 7 11 9 106 8 6 13 13 13 11_ 2"3" 3" 3" 11_ 2" 1" 1" 1014 12 1 3 5 5 6 6 13 13 KEYNOTES: 1.WOOD TRUSS, SEE PLAN 2. 4x12 LEDGER W/ (2) 1/4" DIA x 8" LONG SDS SCREWS AT 16" O.C. 3. ROOF SHEATHING, SEE PLAN 4.WALL SHEATHING AS OCCURS, SEE PLAN 5.WOOD STUD WALL, SEE PLAN 6. BOUNDARY NAILING, SEE PLAN 7.EDGE NAILING, SEE SHEARWALL SCHEDULE 8. BRICK VENEER PER ARCH, ATTACH PER GSN 9. WOOD BEAM, SEE PLAN 10.CONT STRAP W/ NAILING, SEE PLAN KEYNOTES 1 3 4 6 5 7 7 4 10 9 8 2 7 KEYNOTES: NOTES: 3/16 2 3/16 2 3/16 1.STEEL BEAM, SEE PLAN 2. STEEL COLUMN, SEE PLAN 3.WOOD STUD WALL, SEE PLAN 4.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 5.WALL SHEATHING AS OCCURS, SEE PLAN 6. EDGE NAILING, SEE SHEARWALL SCHEDULE 7. CONT 2x BLOCKING W/ A35 CLIP AT 16" O.C. 8.ROOF SHEATHING, SEE PLAN 9. BOUNDARY NAILING, SEE PLAN 10.#10 SELF TAPPING SCREWS AT 4" O.C. 11.BRICK VENEER PER ARCH, ATTACH PER GSN 12.SOFFIT PER ARCH A.COORDINATE ROOF VENTILATION B. FASCIA PER ARCHITECTURAL DETAILS 1 1 3 4 6 7 5 8 9 2'-0" MAX 11 12 11 12 2 10 N O TF O R C O N S T R U C T I O N P U R P O S E S PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : DBP 4/ 5 / 2 0 2 3 9 : 2 5 : 3 6 A M A u t o d e s k D o c s : / / 2 3 - 0 3 8 _ B e e h i v e F ed e r a l C r e d i t U n i o n R e x b u r g / I F 2 3 - 0 3 8 _ B e e h i v e F e d e r a l C r e d i t U n i o n R e x b u r g . r v t S4.1 23-038 BE E H I V E F C U -N O R T H R E X B U R G RO O F F R A M I N G D E T A I L S 02/23/2023 AV SCALE: NTS217STEEL BEAM AT STEEL COLUMN SCALE: NTS218STEEL COLUMN AT WOOD WALL SCALE: NTS220WOOD JOIST AT WOOD BEAM SCALE: NTS221WOOD JOIST AT STEEL BEAM SCALE: NTS222STEEL BEAM AT STEEL COLUMN SCALE: NTS224WOOD TRUSS AT WOOD STUD WALL SCALE: NTS225WOOD JOIST AT STEEL BEAM SCALE: NTS219STEEL BEAM AT STEEL COLUMN SCALE: NTS223STEEL BEAM AT STEEL COLUMN SCALE: NTS226WOOD WALL AT WOOD BEAM SCALE: NTS227STEEL COLUMN AT WOOD STUD WALL KEYNOTES: 1/4 1/4 1/4 1/4 3/16 1/4 1/4 1. STEEL COLUMN, SEE PLAN 2.WOOD BEAM, SEE PLAN 3.WOOD STUD WALL, SEE PLAN 4. 2x NAILER, SEE PLAN KEYNOTES 5.3/8" x 6" x 0'-6" STEEL PLATE 6.1/2" x 3" x 0'-6" STEEL PLATE 7.1/4" x 4" x 0'-5" STEEL PLATE W/ (1) 1/4" DIA x 2 1/2" LONG SDS SCREW EACH FACE 8.1 1/2" LONG SLOTTED HOLE 9.SIMPSON DTT2Z-SDS2.5 W/ 1/2" DIA ANCHOR ROD 1 2 6 5 7 8 2" 11_ 2" 3 9 4 PLAN A A KEYNOTES: 3/16 3/16 3/16 3/16 1/4 1.STEEL COLUMN, SEE PLAN 2. STEEL BEAM, SEE PLAN 3.L2x2x3/16 x 0'-3" (LLV) STEEL ANGLE 4.1/4"x2"x0'-3" STEEL PLATE 1 3 4 2 2 1 4 4 2 SECTION PLAN B A A B KEYNOTES: 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 1. STEEL COLUMN, SEE PLAN 2. STEEL BEAM, SEE PLAN 3.1/4" x 2" x 2" x 0'-3" STEEL PLATE 4. 1/4" x 2" x 0'-3" STEEL PLATE 5.L2x2x3/16x0'-4" TOP AND BOTTOM 6.3/16" x 6" x 0'-10" STEEL PLATE 7.3/16" x 1 1/2" x 0'-10" STEEL PLATE 8. FASCIA PER ARCH 1 1 2 1_ 2" GAP 6 55 7 8 5 1_ 2" GAP 2 5 1' - 0 " 1 1 " 8 2 2 6 7 2 4 1 4 2 3 1_ 2" GAP SEE ARCH 8 2 5 5 KEYNOTES: 1. STEEL BEAM, SEE PLAN 2.ROOF JOIST, SEE PLAN 3.ROOF SHEATHING, SEE PLAN 4. 2x4 SHAPED BLOCKING BETWEEN EACH JOIST 5. BOUNDARY NAILING, SEE PLAN 6. WINDOW SYSTEM, SEE ARCH 1 6 3 5 2" 4 2 KEYNOTES: 1.STEEL BEAM, SEE PLAN 2. ROOF JOIST, SEE PLAN 3.WOOD STUD WALL, SEE PLAN 4.2x6 W/ SIMPSON TB1475S SCREWS AT 12" O.C. 5.WALL SHEATHING AS OCCURS, SEE PLAN 6. WALL SHEATHING ON INTERIOR SIDE WALL WHERE OCCURS PER ARCH 7.ROOF SHEATHING, SEE PLAN 8. CONT BEVELED 2x8 LEDGER W/ SIMPSON TB1475S SCREWS AT 12" O.C. 9. CONT BEVELED 2x W/ 16d NAILS AT 6" O.C. 10. BOUNDARY NAILING, SEE PLAN 11.BRICK VENEER PER ARCH, ATTACH PER GSN 12.SHAPED 2x W/ SIMPSON TB1475S SCREWS AT 24" O.C. 13.SOFFIT PER ARCH 14.EDGE NAILING, SEE SHEARWALL SCHEDULE 10 1 7 2 12 8 9 4 1111 6 5 3 13 10 14 KEYNOTES: 3/16 3/16 3/16 3/16 1.STEEL COLUMN, SEE PLAN 2. STEEL BEAM, SEE PLAN 3.1/2" x 6" x 0'-6" STEEL CAP PLATE 4.2x NAILER, SEE PLAN KEYNOTES 5. BOUNDARY NAILING, SEE PLAN 6.CONT 1x BLOCKING 7.#10 SELF TAPPING SCREWS AT 4" O.C. 2 1 3 2 4 3 576 KEYNOTES: 1.STEEL BEAM, SEE PLAN 2.ROOF JOIST W/ HANGER, SEE PLAN 3. ROOF SHEATHING, SEE PLAN 4.CONT 2x8 W/ (1) SIMPSON TB1475S SCREWS AT 12" O.C. 5.BOUNDARY NAILING, SEE PLAN 6.WEB STIFFENER PER TYPICAL DETAIL 7.2x BLOCKING W/ (3) 16d NAILS BETWEEN EACH JOIST 8.WINDOW SYSTEM, SEE ARCH 3 8 1 6 2 5 7 5 44 SECTIONA A KEYNOTES: 1/4 1/4 1/4 1/4TYP 1/4 1/4 1WEST FACE 1.STEEL COLUMN, SEE PLAN 2. WOOD BEAM, SEE PLAN 3.3/8" x 6" x 1'-0" STEEL PLATE 4.1/2" x 3" x 0'-6" STEEL PLATE 5.1/4" x 4" x 0'-11" STEEL PLATE W/ (2) 1/4" DIA x 2 1/2" LONG SDS SCREWS EACH FACE6. 1 1/2" LONG SLOTTED HOLE 1 24 3 5 6 2 4 5 3 2" 4" 11_ 2" 5 PER AISC 1 1/2" TYP BE A M GA G E SECTION A A KEYNOTES: NOTES: 3/16 3/16 3/16 1. STEEL BEAM, SEE PLAN 2.1/4" THICK STEEL WEB STIFFENER, EACH SIDE OF BEAM 3. 3/4" THICK STEEL CAP PLATE W/ (4) 3/4" DIA THRU BOLTS 4.STEEL COLUMN, SEE PLAN 5.WOOD TRUSS W/ HANGER BY TRUSS MANUFACTURE 6.CONT 4x W/ 5/8" DIA THREADED STUDS W/ WASHER AT 32" O.C. (COUNTER SINK AS REQUIRED) 7.2x4 W/ (3) 16d NAILS 8. A34 CLIP W/ #10 SCREWS TO STEEL 9. ROOF SHEATHING 10.BOUNDARY NAILING, SEE PLAN 9 A.SEE CORRESPONDING DETAILS FOR ADDITIONAL INFORMATION B. AT CONTRACTOR'S OPTION BEAM MAY BE WELDED TO CAP PLATE W/ 3/16" FILLETS EACH SIDE 5 7 7 1 2 3 4 6 8 8 1010 6 9 1 5 5 7 8 2 4 PER AISC 1 1/2" TYP BE A M GA G E SECTION A A KEYNOTES: NOTES: 3/16 3/16 3/16 1.STEEL BEAM, SEE PLAN 2. 1/4" THICK STEEL WEB STIFFENER, EACH SIDE OF BEAM 3. 3/4" THICK STEEL CAP PLATE W/ (4) 3/4" DIA THRU BOLTS 4. STEEL COLUMN, SEE PLAN 5.WOOD TRUSS W/ CLIP, SEE PLAN 6.CONT 4x W/ 5/8" DIA THREADED STUDS W/ WASHER AT 32" O.C. (COUNTER SINK AS REQUIRED) 7.2x4 W/ (3) 16d NAILS 8. A34 CLIP W/ #10 SCREWS TO STEEL 9.2x4 FRAMING SISTERED TO TRUSS TOP AND BOTTOM CHORD W/ (2) 16d NAILS AT 24" O.C. 10. 2x8 FRAMING SISTERED TO 2x4 FRAMING W/ (3) 16d NAILS AT 24" O.C. 11.CONT 2x8 W/ (2) 16d NAILS AT 24" O.C. 12.ROOF SHEATHING, SEE PLAN 13. BOUNDARY NAILING, SEE PLAN 14.TYPE 5 WALL SHEATHING AS OCCURS, SEE SHEARWALL SCHEDULE 15. EDGE NAILING, SEE SHEARWALL SCHEDULE 16. 2x BLOCKING W/ A35 CLIP BETWEEN EACH TRUSS 17. CONT 2x4 PLATE W/ (1) #10 x 3 1/2 WOOD SCREW AT 24" O.C. 11 14 12 9 10 A. SEE CORRESPONDING DETAILS FOR ADDITIONAL INFORMATION B.AT CONTRACTOR'S OPTION BEAM MAY BE WELDED TO CAP PLATE W/ 3/16" FILLETS EACH SIDE 5 15 15 13 15 7 7 1 2 3 4 6 8 8 14 1312 16 4 8 1 2 6 5 7 17 17 N O TF O R C O N S T R U C T I O N P U R P O S E S PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : DBP 4/ 5 / 2 0 2 3 9 : 2 5 : 3 6 A M A u t o d e s k D o c s : / / 2 3 - 0 3 8 _ B e e h i v e F ed e r a l C r e d i t U n i o n R e x b u r g / I F 2 3 - 0 3 8 _ B e e h i v e F e d e r a l C r e d i t U n i o n R e x b u r g . r v t S4.2 23-038 BE E H I V E F C U -N O R T H R E X B U R G RO O F F R A M I N G D E T A I L S 02/23/2023 AV SCALE: NTS228STEEL COLUMN AT WOOD STUD WALL SCALE: NTS229STEEL BEAM AT STEEL COLUMN SCALE: NTS230STEEL BEAM AT STEEL COLUMN SCALE: NTS231WOOD JOIST AT STEEL BEAM SCALE: NTS232WOOD JOIST AT STEEL BEAM SCALE: NTS233STEEL BEAM AT STEEL COLUMN SCALE: NTS234WOOD JOIST AT WINDOW SYSTEM SCALE: NTS235WOOD BEAM AT STEEL COLUMN SCALE: NTS236WOOD TRUSS AT STEEL BEAM SCALE: NTS237WOOD TRUSS AT STEEL BEAM SECTION A A KEYNOTES: 1.WOOD TRUSS W/ INTEGRAL OVERHANG FRAMING W/ CLIP, SEE PLAN 2. STEEL BEAM, SEE PLAN 3.CONT 4x W/ 5/8" DIA THREADED STUDS W/ WASHER AT 32" O.C. (COUNTERSINK AS REQUIRED) 4.TYPE 5 WALL SHEATHING AS OCCURS, SEE SHEARWALL SCHEDULE 5.ROOF SHEATHING, SEE PLAN 6.2x BLOCKING W/ A35 CLIP BETWEEN EACH TRUSS 7.BOUNDARY NAILING, SEE PLAN 8. 2x4 FRAMING SISTERED TO TRUSS TOP AND BOTTOM CHORD W/ (2) 16d NAILS AT 24" O.C. 9. 2x8 FRAMING SISTERED TO 2x4 FRAMING W/ (3) 16d NAILS AT 24" O.C. 10. CONT 2x8 W/ (2) 16d NAILS AT 24" O.C. 11.CONT 2x4 PLATE W/ (1) #10 x 3 1/2 WOOD SCREWS AT 24" O.C. 12.EDGE NAILING, SEE SHEARWALL SCHEDULE 10 4 8 9 12 12 12 4 75 6 2 3 7 11 10 1 11 9 1' - 0 " MA X 7 1 8 5 KEYNOTES: 1. WOOD TRUSS W/ HANGER BY TRUSS MANUFACTURE 2. STEEL BEAM, SEE PLAN 3. CONT 4x W/ 5/8" DIA THREADED STUDS W/ WASHER AT 32' O.C. (COUNTERSINK AS REQUIRED) 4.ROOF SHEATHING, SEE PLAN 5.BOUNDARY NAILING, SEE PLAN 55 3 4 2 1 1 KEYNOTES: 1.WOOD TRUSS W/ CLIP, SEE PLAN 2. WOOD STUD WALL, SEE PLAN 3.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 4.WALL SHEATHING AS OCCURS, SEE PLAN 5.ROOF SHEATHING, SEE PLAN 6. EDGE NAILING, SEE SHEARWALL SCHEDULE 7.FULL-HEIGHT TRUSS BLOCKING BETWEEN EACH TRUSS W/ A35 CLIP 8.A35 CLIP AT 24" O.C. 9. BOUNDARY NAILING, SEE PLAN 10.CONT 2x BOTTOM PLATE W/ ATTACHMENT, SEE SHEARWALL SCHEDULE11. L6x4x5/16 (LLV) STEEL GALVANIZED ANGLE W/ (2) 1/4" DIA x 4 1/2" LONG STAINLESS SDS SCREWS AT EACH STUD 12. BRICK VENEER PER ARCH, ATTACH PER GSN 13. HORIZONTAL STRAP AS OCCURS, SEE PLAN 8 511_2" 3" 6 1242 6 11 12 4 2 1 7 3 13 9 10 N O TF O R C O N S T R U C T I O N P U R P O S E S PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : DBP 4/ 5 / 2 0 2 3 9 : 2 5 : 3 6 A M A u t o d e s k D o c s : / / 2 3 - 0 3 8 _ B e e h i v e F ed e r a l C r e d i t U n i o n R e x b u r g / I F 2 3 - 0 3 8 _ B e e h i v e F e d e r a l C r e d i t U n i o n R e x b u r g . r v t S4.3 23-038 BE E H I V E F C U -N O R T H R E X B U R G RO O F F R A M I N G D E T A I L S 02/23/2023 AV SCALE: NTS238WOOD TRUSS AT STEEL BEAM SCALE: NTS239WOOD TRUSS AT STEEL BEAM SCALE: NTS240WOOD TRUSS AT WOOD STUD WALL M MECHANICAL LEGEND S L SUPPLY AIR REFRIGERANT LIQUID LINE REFRIGERANT SUCTION LINE ELECTRONIC THERMOSTAT EQUIPMENT SYMBOL PLAN NOTE ABOVE FINISHED FLOOR OUTSIDE AIR RETURN AIR FC 1 T AFF 1 SA OA RA INSULATED FLEXIBLE DUCT (SUPPLY AIR) CEILING DIFFUSER ROUND BRANCH DUCT WITH HAND DAMPER RECTANGULAR SUPPLY AND RETURN AIR DUCT TAKE-OFF TURNING VANES DUCT TRANSITION HAND DAMPER HD DESCRIPTIONSYMBOL SYMBOL DESCRIPTION FURNACE SIDEWALL REGISTER (RETURN AIR) LOW SIDEWALL GRILLECONDENSING UNIT PIPE DROP PIPE RISE MOTORIZED DAMPER EXHAUST FAN CEILING MOUNTED ELECTRIC WALL HEATER RETURN AIR GRILLE RISE 20" DIA. RETURN DUCT UP THRU FLOOR AND CONNECT TO RETURN AIR PLENUM ABOVE. TYPICAL SHEET METAL BOOT UP TO FLOOR GRILLE. REFER TO DETAIL K/M2.1 FOR TYIPCAL INSTALLATION. REFER TO DETAIL K/M2.1 FOR TYPICAL UNDERFLOOR DUCT INSTALLATION REFER TO DETAIL K/M2.1 FOR TYPICAL UNDERFLOOR DUCT INSTALLATION TYPICAL SHEET METAL BOOT UP TO FLOOR GRILLE. REFER TO DETAIL K/M2.1 FOR TYIPCAL INSTALLATION. 10"ø 20 " ø 20 " ø 10"ø 10"ø 10"ø 10 " ø 10 " ø 10"ø 14 " ø A A B BC CD D E E 66 55 44 33 22 11 10"ø 10"ø Engineered Systems Associates PHONE: 1355 EAST CENTER POCATELLO, IDAHO 83201 ESA JOB NUMBER: FAX:(208) 233-0529 (208) 233-0501 EMAIL:esa@engsystems.com 23005 G D AH S P-18184 T A D I A V D S DT E O L. I H NA F S R E PROF N E SGI E ERT AISONL E NEO I R E EN 3/14/2023 PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 3/ 2 4 / 2 0 2 3 1 0 : 3 0 : 0 4 A M 2 3 0 0 5 B E E H I V E F C U ( M & P ) _ d e t a c h ed . r v t M1.0 19035 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . ME C H A N I C A L F O U N D A T I O N P L A N February 2023 A N E W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 M JENSEN D HANSEN SCALE:1/4" = 1'-0" MECHANICAL FOUNDATION PLAN CD-1 300 CD-2 300 CD-2 300 CD-2 300 CD-3 100 CD-3 150 CD-3 150 EH 1 FG-1FG-1 FG-1 FG - 1 FG - 1 FG-1 T TYPICAL FLOOR GRILLE WITH BOOT THRU FLOOR. REFER TO DETAIL K/M2.1 FOR TYPICAL INSTALLATION. HD HD HD HD HDHD HD T RG-1 RG-1 (2) RG-1 RG-3 (4) RG-1RG-1 RG-2 SR-1 400 SR-1 300 SR-1 300 DROP 12x3 (UNLINED) DUCT DOWN IN WALL TO GRILLE LOCATED 6" ABOVE FLOOR. (TYPICAL OF 8.) REFER TO DETAIL A/M3.1 FOR TYPICAL INSTALLATION. MOUNT CENTER OF REGISTER AT 10'-2" ABOVE FLOOR. (TYP. OF ALL SIDEWALL REGISTERS. SR-1 200 SR-1 200 CD-4 150 EF 3 IN TOE SPACE EXTEND (2) 12x3 DUCTS INTO TOE SPACE EF 1 EF 2 RISE 8" Dia. DUCT UP THRU ROOF WITH ROOF CAP. (TYPICAL OF ALL EXHAUST FANS.) EF 4 OL-1 INSTALL 14" HIGH RETURN AIR PLENUM BELOW FURNACES. CUT FULL SIZE OPENING FOR FURNACES AND RETURN AIR AND OUTSIDE AIR DUCT. REFER TO DETAIL B/M2.1. F 1 F 2 CU 1 CU 2 RISE (2) 3" Dia. VENTS UP FROM EACH FURNACE AND EXTEND THRU ROOF WITH CONCENTRIC VENT KIT. REFER TO DETAIL F/M2.1 FOR TYPICAL VENT INSTALLATION. PROVIDE 1" THICK NEOPRENE PADS UNDER CONDENSING UNITS AT EACH CORNER COVER EXPOSED REFRIGERANT LINES WITH PRE-FINISHED SHEET METAL COVER. REFER TO DETAIL B/M3.1. 1 1 3 4 2 2 5 5 FG-1 5 5 6 6 7 6 6 6 CD-4 150 10 " x 1 2 " 12 " x 8 " 10 " x 1 6 " 16"x8" 16"x8" 16"x8" 10 " x 1 8 " 12 " x 1 8 " 12 " x 8 " 18 " x 1 0 " 18"x12"18"x14"18"x14" 18"x14"18"x10" 18"x10"24"x12" 24"x12" 24 " x 1 2 " 8" ø 8"ø 12"x6" 10"ø 10"ø 6"ø 6"ø 18"x12" SR-1 200 12 " x 1 0 " 12"x8" CC CCA A B BC CD D E E 66 5 4 3 2 11 3.5 1.5 4.8 12"x6" 16 " x 8 " 8"ø F-2 F-1 HD HD HD HD HD HD HD HD FC 1A8 VESTIBULE 101 MANAGER 103 MAIN LOBBY 102 OFFICE 3 115 OFFICE 2 113 MAIN LOBBY 102 OFFICE 1 104 DRIVE-THRU 106 BREAK 107 HALLWAY 108 TOILET 118 TOILET 117 I.T. 116 JAN./STOR. 112 MECH. 111 FC 1B Engineered Systems Associates PHONE: 1355 EAST CENTER POCATELLO, IDAHO 83201 ESA JOB NUMBER: FAX:(208) 233-0529 (208) 233-0501 EMAIL:esa@engsystems.com 23005 G D AH S P-18184 T A D I A V D S DT E O L. I H NA F S R E PROF N E SGI E ERT AISONL E NEO I R E EN 3/14/2023 PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 3/ 2 4 / 2 0 2 3 1 0 : 3 0 : 0 5 A M 2 3 0 0 5 B E E H I V E F C U ( M & P ) _ d e t a c h ed . r v t M1.1 19035 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . ME C H A N I C A L F L O O R P L A N February 2023 A N E W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 M JENSEN D SUDWEEKS SCALE:1/4" = 1'-0" MECHANICAL FLOOR PLAN PLAN NOTES: 1 PROVIDE AND INSTALL GAS FIRED FURNACE AS SPECIFIED. MOUNT FURNACE ON TOP OF 14" HIGH RETURN AIR PLENUM. (REFER TO DETAIL B/M2.1.) MOUNT DX COOLING COIL ON TOP OF FURNACE AND RISE DUCTWORK UP TO ABOVE CEILINGS. EACH FURNACE TO BE COMPLETE WITH (2) 3" Dia. VENTS UP THRU ROOF. EXTEND VENTS THRU ROOF WITH CONCETRIC TYPE FITTING. (REFER TO DETAIL F/M2.1.) CONNECT 3/4" GAS LINE TO EACH FURNACE WITH SHUT-OFF VALVE AND FLEXIBLE HOSE. (REFER TO DETAIL E/P2.1.) COORDINATE FURNACE LOCATIONS WITH DUCTWORK RISING UP THRU FLOOR. PROVIDE SHEET METAL DIVIDER IN PLENUM BASE TO SEPARATE EACH FURNACE SYSTEM. PROVIDE AND INSTALL CONDENSING UNITS SPECIFIED. MOUNT UNITS IN MECHANICAL COMPOUND WITH 1" THICK NEOPRENE PADS UNDER EACH CORNER. RUN REFRIGERANT LINE AT GRADE LEVE AND COVER WITH SHEET METAL COVER. REFER TO DETAILS B/M3.1 AND C/M3.1 FOR TYPICAL REFRIGERANT PIPING INSTALLATION AND CONNECTION. PROVIDE AND INSTALL OUTSIDE AIR LOUVER AS SPECIFIED. MOUNT AS HIGH AS POSSIBLE AND EXTEND FULL SIZED SLEEVE THRU WALL AND ABOVE RETURN AIR PLENUM. CONNECT (2) 10x6 OUTSIDE AIR DUCTS TO BOTTOM OF 18x12 LOUVER SLEEVE. DROP EACH 10x6 DUCT DOWN AND CONNECT TO RETURN AIR PLENUM OF RESPECTIVE FURNACE SYSTEM. PROVIDE MOTORIZED DAMPER, MANUAL BALANCING DAMPER AND DUCT ACCESS DOOR IN EACH DUCT. BALANCE MANUAL DAMPER TO CFM AS INDICATED ON FURNACE SCHEDULE. REFER TO DETAIL D/M2.1 FOR TYPICAL DAMPER INSTALLATION. PROVIDE AND INSTALL CEILING MOUNTED EXHAUST FAN AS SPECIFIED. RUN 8" Dia. DUCT UP THRU ROOF WITH ROOF CAP. ALL ROOF CAPS ARE TO BE LOCATED IN LOWER ROOF SECTION. REFER TO DETAIL J/M2.1 FOR TYPICAL INSTALLATION. MOUNT RETURN AIR GRILLE AT 6" ABOVE FLOOR AND RISE 12x3 UNLINED RETURN DUCT UP IN WALL CAVITY. REFER TO DETEAIL A/M3.1 FOR TYPICAL INSTALLATION. MOUNT RETURN AIR GRILLE AS SPECIFIED IN TOE SPACE OF MILLWORK. LEAVE OPEN TO BOTTOM OF MILLWORK. DROP 12x3 RETURN DUCTS DOWN IN WALL AS SHOWN AND ALSO EXTEND INTO SPACE BELOW MILLWORK. MOUNT INDOOR FAN COIL UNIT ON WALL AT 8'-0" ABOVE FLOOR. RUN REFRIGERANT LINES THRU BUILDING AS SHOWN. PIPING TO EXIT BUILDING AT GRADE LEVEL TO CROSS MECHANICAL ENCLOSURE. 3 4 5 6 7 8 L NO SCALE A I R F L O W AIR BRANCH DUCT (TYPICAL) USE DAMPER WHEN INDICATED ON FLOOR PLAN NOTE: L=1/4 W (4" MINIMUM) MAIN AIR DUCT 45° W ANGLES ON ALL 4 SIDES. WELDED CONSTRUCTION W/ STAND BELOW FURNACE. 1-1/2"x3/16" ANGLE IRON EQUIPMENT FURNISHED. SIZE FRAME TO MATCH FURNACE INLET. PLENUM TO MATCH TOP PANEL OF CUT OPENING IN 8x8 ACCESS DOOR 14" HIGH RETURN AIR PLENUM AN AIRTIGHT SEAL (TYPICAL). EDGES OF PLENUM TO PROVIDE AROUND FURNACE AND AT ALL PROVIDE SILICONE SEALANT FURNACE. ANGLE STAND BELOW ANGLE SUPPORTS AND INSIDE EXCEPT AT THICK DUCT LINER ON METAL PLENUM WITH 1" 20 GAUGE GALV. IRON CONSTRUCTION. OF PLENUM WITH WELDED FRAME ON ALL 4 SIDES 1-1/2"x3/16" ANGLE IRON NO SCALE REINFORCING MENDED GAGE 24 26 DRIVE RECOM- SLIP NO SCALE 19 - 30 13 - 18 UP THRU 12 LONGEST INCHES SIDE, DIMENSION NONE REQUIRED26 NONE REQUIRED 1"x1"x1/8" @ 60 IN24 24 (ALL FOUR SIDES) OF GAGE METAL SHEET BETWEEN INTERMEDIATE REINFORCING JOINTS &/OR TRANSVERSE ANGLE SIZE SPACING LONGITUDINAL AND MAXIMUM 2"2" 26 MAX. 12" OC 24 24- S SLIP RECOM- MENDED GAGE HEMMED 1" TRANSVERSE REINFORCING (1) MINIMUM AT JOINTS (1) TRANSVERSE REINFORCING SIZE IS DETERMINED BY DIMENSION OF SIDE TO WHICH ANGLE IS APPLIED. GRIP NAILS SHALL BE INSTALLED BY GRIPNAIL AIR HAMMER OR BY AUTOMATIC FASTENER EQUIP. METAL FASTENERS - OMARK INSULPINS, DURO DYNE FASTENERS OR GRIPNAILS. STRAPS TO BE TIGHT AGAINST DUCTWORK HANG DUCTS UP TO 30" WIDTH WITH 1" x 18 GAGE STRAPS AT 10'-0" MAXIMUM SPACING. SELF-TAPPING CADMIUM PLATED HEX HEAD SHEET METAL SCREW NO POP RIVETS ALLOWED HANGER STRAPS SHEET METAL DUCT NOT MORE THAN 2" FROM EDGE OF LINER ALL ENDS OF LINER TO BE COATED WITH ADHESIVE. SEE SPECIFICATIONS. 1" THICK DUCT LINER TOP AND BOTTOM SECTION OF LINER SHALL OVERLAP THE SIDES ENDS OF LINER SHALL BE BUTTED FIRMLY TOGETHER LINER TO BE ADHERED TO DUCT W/100% ADHESIVE SEE SPECIFICATIONS. NO SCALE DUCT SUPPORT 1" ACOUSTICAL DUCT LINER ON INTERIOR OF DUCT. 24" MAX TO FIRST SUPPORT RIGID SPIN- IN FITTING HAND DAMPER HANDLE ROUND RIGID DUCT. WING NUT RECTANGULAR SUPPLY DUCT GLUE FLEX DUCT TO FITTING, CLAMP DOWN WITH STRAP AND SCREW SOLID TO RIGID FITTING ATTACH TO RIGID DUCT WITH DRAW BAND OPPOSED BLADE DAMPER WHERE SPECIFIED LAY-IN DIFFUSER LAY-IN CEILING ROUND TO SQUARE TRANSITION GLUE FLEX DUCT TO ADAPTER & CLAMP DOWN WITH STRAP. ROUND FLEXIBLE SUPPLY DUCT TO CEILING DIFFUSER 8'-0" MAX. LENGTH 24" MAX TO FIRST SUPPORT DUCT SUPPORT EXTERNAL DUCT INSULATION ON ALL ROUND RIGID DUCT- WORK AND FITTINGS. NO SCALE 6" 6" 4" MIN. PEA GRAVEL OR SAND. FILL MATERIAL SHOULD BE HAND TAMPED, RODDED OR LIGHTLY COMPACTED DURING INSTALLATION. CARE SHOULD BE TAKEN DURING THIS PROCEDURE NOT TO DEFORM OR OTHERWISE DAMAGE THE DUCT. TAKE-OFF MAY BE MADE TOP TANGENT OR BOTTOM TANGENT TAPE ALL AROUND JOINT AS PER SPECIFICATIONS.GALVANIZED SHEET METAL SLEEVE INSIDE OF DUCT COMPACTED EARTH UNDERFLOOR AIR DUCT 90° TEE FITTING 4" MIN. 3-1/2" MIN. CONCRETE FLOORCONCRETE AROUND ENTIRE BOOT 1-1/2" BOOT FLANGE TAPE ALL AROUND JOINT, TO BE AS PER SPECIFICATIONS AIR DUCT ANCHOR BOOT FLANGE TO BOOT W/ SHEET METAL SCREWS 20 GA. GALVANIZED SHEET METAL BOOT RETURN AIR 1/2" BOOTLINER BOOT 1/2" BOOTLINER BY MECH. CONT. 2" INSULATION BY GEN. CONT.4" MIN. NO SCALE APPROX. 6" SCREW SLEEVE SECURELY TO 2x4 BRACING. SCREW HEAD TO BE INSTALLED INSIDE OF SLEEVE (TYPICAL OF 4) ROOF FLASHING ACCUMULATION 18" MINIMUM ABOVE AVERAGE SNOW INTAKE EXHAUST CLAMP SHEET METAL STRAP 20 GA GALVANIZED SLEEVE. ALLOW PIPING TO MOVE 20 GA GALVANIZED FREELY THRU SLEEVE INTAKEEXHAUST NO SCALE TO MAIN RA DUCT MANUAL OUTSIDE AIR DAMPER. BALANCE OUTSIDE AIR AS INDICATED ON LARGE SCALE FLOOR PLANS OR SCHEDULE. MOTORIZED OUTSIDE AIR DAMPER. OA FROM LOUVER 6x6 DUCT ACCESS DOOR L NO SCALE A I R F L O W MAIN AIR DUCT NOTE: L=1/4 W (4" MINIMUM) SIDEWALL GRILLE W 45° NO SCALE 2' - 0" MAXIM U M FOOT OF SUPPORT SPACING. MAX. SAG 1/2" PER BAND CLAMP 1"x18 GAGE SECURE TO STRUCTURE. ROOF (SEE ARCH. DWGS) AND SEAL WATERTIGHT FLASH INTO SHINGLES ROOF CAP (SLOPED ROOF) 6" Dia. EXHAUST DUCT DAMPER BACK-DRAFT CEILING GRILLE CEILING EXHAUST FAN FAN ASSEMBLY CABINET INSULATED NO SCALE DAMPER BACK-DRAFT MANUAL BALANCING DAMPER RECTANGULAR DUCT CONNECTION DETAILA RETURN AIR PLENUM DETAILB DUCT CONSTRUCTION AND HANGER DETAILC CEILING DIFFUSER DETAIL WITH FLEXIBLE DUCTG UNDERFLOOR DUCT & BOOT CONNECTION DETAIL NOTE K CONCENTRIC VENT TERMINATION DETAILF TYPICAL OUTSIDE AIR DUCT DETAILD SIDEWALL GRILLE CONNECTION DETAILE FLEXIBLE DUCT SUPPORT DETAILH CEILING MOUNTED EXHAUST FAN DETAILJ CUT OPENING IN TOP OR BOTTOM OF PANEL FOR RETURN / OUTSIDE AIR DUCT AS REQUIRED. Engineered Systems Associates PHONE: 1355 EAST CENTER POCATELLO, IDAHO 83201 ESA JOB NUMBER: FAX:(208) 233-0529 (208) 233-0501 EMAIL:esa@engsystems.com 23005 G D AH S P-18184 T A D I A V D S DT E O L. I H NA F S R E PROF N E SGI E ERT AISONL E NEO I R E EN 3/14/2023 PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 3/ 2 4 / 2 0 2 3 1 0 : 3 0 : 0 5 A M 2 3 0 0 5 B E E H I V E F C U ( M & P ) _ d e t a c h ed . r v t M2.1 19035 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . ME C H A N I C A L D E T A I L S February 2023 A N E W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 M JENSEN D SUDWEEKS FAN COIL SPLIT SYSTEM A/C UNIT SCHEDULE PROVIDE MITERED CONNECTION. CEILING FLOOR 6" 12" x 3" UNLINED DUCT IN WALL CAVITY MAIN RETURN DUCT ABOVE CEILING WITH 1" ACOUSTICAL LINER. TYPICAL RETURN AIR GRILLE RETURN AIR GRILLE DETAILA REFRIG. PIPING SUPPORT AT WALLB REFRIGERANT PIPING DIAGRAMC MIN-SPLIT SYTEM REFRIGERANT PIPING DIAGRAMD NO SCALE NOTE: INSULATION BRICK COLOR (TYP) PAINT ANGLE SUPPORTS TO MATCH BLDG. FACE SEAL WALL PENETRATIONS BUILDING WALL WATER TIGHT. SUCTION LINES SHOWN. LIQUID LINE SIMILAR. SUCTION LINE AGAINST CLAMP ASSEMBLY. BUTT INSULATION OF OR EQUAL. 1-5/8" P-3300 "UNISTRUT" 6" x 4" x 1/4" ANCHORED TO STRUCTURE WITH 1/2" x 5-1/2" NO SCALE SIDES (TYPICAL). OR EQUAL. WELD BOTH EXPANSION BOLTS BY THE ENGINEER 26 GA. PRE-FINISHED SHEET METAL COVER. COLOR TO BE SELECTED "CUSH-A-CLAMP" WITH "HYDRA-ZORB", PIPING TO SUPPORTS SECURE REFRIGERANT METAL COVER 18 GA. GALV. WEATHERTIGHT CAULK ALL AROUND 3/4" CD TO FLOOR DRAIN FILTER DRYER NO SCALE SIGHT GLASS WALL ANCHOR EXPANSION VALVE L UNIT CONDENSING AT RISE AND 8'-0" MAXIMUM SPACING PIPE SUPPORT AT DROP S S L PIPE SUPPORT FURNACE COIL SECTION CORNER OF UNIT PADS AT EACH ISOLATION PADS NO SCALE CONDENSING UNIT SCHEDULE ELECTRIC HEATER SCHEDULE EXHAUST FAN SCHEDULE FURNACE SCHEDULE GRILLE AND REGISTER SCHEDULE WEIGHT 200#240/60/148,0001 CU 95°F 28.9 CHAR.SYM. BTU EAT MCA REMARKS 240#240/60/160,0002 CU 95°F 34.6 EH 1 SYM.TYPE SEMI-RESSED WALL MOUNTED 6824 MBH 2.0 KW 208/240V - 1 PH CHAR CONTROL INTEGRAL REMARKS S.P.E. 1 EF SYM.TYPE CEILING MOUNTED C.F.M. 200 CONTROLCHAR.WATTS 127.25" 120/60/1 R.P.M. 740 WITH LIGHTS REMARKS 2 EF CEILING MOUNTED 200 127.25" 120/60/1 740 WITH LIGHTS 0.A. CFM UP-FLOW1 F SYM.TYPE 1600 400 DESIGN CFM REMARKSCHAR.H.P. 1.75" SP E 120/06/1 A.G.A. 88,000 INPUT 85,000 OUTPUT VENTLAT 65°F 110°F EAT 1/2" SUP (2) 3" Dia. NAT. GAS TYPE UP-FLOW2 F 1900 300 1.75" 120/60/1 110,000 106,000 65°F' 109°F 1/2" (2) 3" Dia.NAT. THROW CD-1 SYM. 9 x 9 SIZE BRANCHCONSTR. 50-200 CFM STEEL FINISH WHITE 8" Dia. DUCT NO F.D. NO O.B.REMARKS CD-2 12 x 12 150-400 STEEL WHITE 10" Dia. NO NO CD-3 9 x 9 50-200 STEEL WHITE 8" Dia. NO NO RG-1 12 x 6 50-150 STEEL WHITE 12 x 3 NO NO RG-2 12 x 12 200-400 STEEL WHITE 12 x 8 NO NO FG-1 24 x 6 200-350 ALUM ANODIZED 24 x 6 NO NO SR-1 12 x 8 300 STEEL WHITE 12 x 8 NO NO CD-4 STEEL WHITE NO NO OL-1 18 x 12 600 ALUM ANODIZED 18 x 10 NO NO 3 EF CEILING MOUNTED 200 127.25" 120/60/1 740 WALL SWITCH 4 EF CEILING MOUNTED 100 87.25" 120/60/1 640 WALL SWITCH RG-3 2 x 10 100-120 STEEL WHITE --- NO NO PRICE MODEL SMD IN 24x24 LAY-IN MODULE PRICE MODEL SMD IN 24x24 LAY-IN MODULE PRICE MODEL SMD WITH BEVELED FRAME PRICE MODEL SMD WITH BEVELED FRAME PRICE MODEL 520L. MOUNT AT 11'-0" ABOVE FLOOR PRICE MODEL 535. MOUNT AT 6" ABOVE FLOOR PRICE MODEL 535 TOE SPACE GRILLE PRICE MODEL LBPH-25C WITH HEAVY-DUTY FLANGED BORDER AND 24x6 BOOT AMERICAN WARMING LE-31 WITH DRAINABLE BLADES AND BIRD SCREEN LENNOX EL195UH090P48C WITH FULLY CASED, MATCHING DX COOLING COIL. LENNOX EL195UH110P60D WITH FULLY CASED, MATCHING DX COOLING COIL. TWIN CITY MODEL T200 WITH BACK-DRAFT DAMPER AND 8" Dia. DUCT UP TO ROOF CAP. TWIN CITY MODEL T200 WITH BACK-DRAFT DAMPER AND 8" Dia. DUCT UP TO ROOF CAP. TWIN CITY MODEL T200 WITH BACK-DRAFT DAMPER AND 8" Dia. DUCT UP TO ROOF CAP. TWIN CITY MODEL T100 WITH BACK-DRAFT DAMPER AND 4" Dia. DUCT UP TO ROOF CAP. QMARK MODEL AWH4404 WITH AWH-S-1 WALL MOUNTING FRAME LENNOX ACX-048 WITH LOW AMBIENT 'HARD-START' KIT. LENNOX ACX-060 WITH LOW AMBIENT 'HARD-START' KIT. 9 x 9 50-200 8" Dia. FLOOR BOLT TO CONC. PAD CONCRETE ENCLOSURE BASE 14" PUMP-UP PAD WALL WIRING IN WALL CONDUIT AND 1A FC FC 1B NOTE: 1'-0" MIN. CLEARANCE AROUND UNIT. DO NOT LOCATE CONDENSING UNIT BELOW DRIP EDGE OF ROOF. ADJUST LOCATION OF UNIT ACCORDINGLY. WALL MOUNT DIGITAL CONTROLLER PRE-CHARGE LINE SETS ARE AVAILABLE IN LENGTHS OF 16, 20, 32 AND 49 FEET. LENGTHS ARE TO BE KEPT AS SHORT AS POSSIBLE. COILING OF LINES THAT ARE TOO LONG WILL NOT BE ACCEPTABLE AND WILL BE REPLACED AT CONTRACTOR'S EXPENSE. FC 1A 300-400 1 208/60/1MITSUBISHI MODEL PKA-A18HA718,000 REFRIG. LINES LIQUID SUCTION FC 1B 18,000 15.3 CHARSEERBTUSYM.MCABTUCFMSYM. OUTDOOR UNITINDOOR UNIT 208/60/1 CHAR MITSUBISHI PUYA18NHA7 WITH LOW AMBIENT 'HARD-START' KIT MANUFACTURER 1/4" 1/2"20 MCA 8' - 0 " A B O V E F L O O R RUN REFRIGERANT LINES AT CEILING. SEE FLOOR PLAN CONNECT DRAIN LINE TO LAVATORY WITH DISHWASHER TYPE FITTING. Engineered Systems Associates PHONE: 1355 EAST CENTER POCATELLO, IDAHO 83201 ESA JOB NUMBER: FAX:(208) 233-0529 (208) 233-0501 EMAIL:esa@engsystems.com 23005 G D AH S P-18184 T A D I A V D S DT E O L. I H NA F S R E PROF N E SGI E ERT AISONL E NEO I R E EN 3/14/2023 PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 3/ 2 4 / 2 0 2 3 1 0 : 3 0 : 0 5 A M 2 3 0 0 5 B E E H I V E F C U ( M & P ) _ d e t a c h ed . r v t M3.1 19035 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . EQ U I P M E N T S C H E D U L E S & D E T A I L S February 2023 A N E W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 M JENSEN D SUDWEEKS ROOF DRAIN DETAIL LOCATE ROOF DRAINS IN ROOF SUMP DRAIN OVERFLOW UNDERDECK NO SCALE OVERFLOW LINE RDL CLAMP SEE ARCHITECTURAL DRAWINGS ROOF DRAIN 3'-0" 36" SQUARE LEAD FLASHING UNDER SINGLE PLY ROOF MEMBRANE DECK ROOF DAM 2" HIGH WATER G RDL RDO PLUMBING LEGEND CD WC-1 L-1 FD-1 JS-1 DF-1 WH-1 TP-1 RO-1 RD-1 WF-1 RP-1 HB-1 S-1 FIXTURE SCHEDULE COLDDESCRIPTIONSYM.HOT WASTE VENT --- 1/2" 4" 2" 1-1/2"1-1/2"1/2"1/2" --- --- 2" 2" 2"2"1/2"1/2" 1-1/2"1-1/2"1/2"--- ------3/4"3/4" ------1/2"--- ---3"------ ---3"------ 3"--- --- --- STAINLESS STEEL SINGLE DRINKING FOUNTAIN - ELKAY MODEL STAINLESS STEEL DRINKING FOUNTAIN WITH PUSH-BUTTON CONTROL, STAINLESS STEEL WALL MOUNTING PLATE AND RECESSED COOLER. MOUNT AT ADA HEIGHT. 2" FLOOR DRAIN WITH PRIMER - ZURN Z-415B WITH 5" Dia. NICKEL-BRONZE STRAINER AND 2" DEEP SEAL P-TRAP WITH ZURN 1022 TRAP PRIMER MOUNTED UNDER NEAREST LAVATORY FLOOR MOUNTED SERVICE SINK - KOHLER K-6710 "WHITBY" W/ K-8940 WIRE RIM GUARD, K-8928 FAUCET ASSEMBLY AND K-9142 STRAINER WITH DEEP SEAL P-TRAP. ADA WALL MOUNTED LAVATORY - KOHLER MODEL K-2032 "GREENWICH" (SIZE 20x18) WITH ELKAY LK656 METERED FAUCET, K-7129A OPEN GRID STRAINER, 1/2" BALL STOPS AND 1-1/2" P-TRAP. INSULATE HOT WATER SUPPLY AND TRAP WITH JACKET. 3" ROOF DRAIN - JAY R. SMITH MODEL 1010 WITH DOME STRAINER, UNDER DECK CLAMP AND 3" LINE CONNECTION. 3" OVERFLOW DRAIN - JAY R. SMITH MODEL 1080 WITH DOME STRAINER, 2" HIGH WATER DAM, UNDER DECK CLAMP AND 3" LINE CONNECTION. TRAP PRIMER ZURN Z-1022XL IN-LINE PRIMER. MOUNT BELOW LAVATORY AND RUN 1/2" COLD WATER LINES BELOW FLOOR TO CORRESPONDING FLOOR DRAIN. REFER TO DETAIL D/P2.1. ADA TANK TYPE VALVE WATER CLOSET - KOHLER K-3516 "NORTHLINE" WITH ELONGATED BOWL, K-4670C WHITE OPEN FRONT SEAT AND BOLT CAPS. WALL FLANGE - JAY R SMITH MODEL 1770 WITH ROUGH-BRASS FINISH AND 3" LINE CONNECTION. MOUNT HIGH IN PARAPET. ELECTRIC WATER HEATER - A.O. SMITH MODEL EJCS-40 ELECTRIC WATER HEATER WITH 4500 WATT UPPER & LOWER ELEMENTS. (240V. NON-SIMULTANEOUS) AMTROL ST-5 EXPANSION TANK, T&P VALVE AND SYMMONS 5-200 (3/4") MIXING VALVE. ---------3/4"HOT WATER RECIRC PUMP - B&G SERICES LR-20BF 'LITTLE RED' WITH 4 GPM FLOW AT 8' HEAD AND 3/4" LINE CONNECTIONS. MOUNT NEAR WATER HEATER. REFER TO DETAIL F/P2.1 FOR TYPICAL PIPE CONNECTIONS --- 3/4" --- --- EXTERIOR HOSE BIBB - ZURN Z-1310 "ECOLOTROL" WITH VACUUM BREAKER AND REMOVABLE TEE HANDLE. LENGTH TO SUIT WALL THICKNESS. 1-1/2"1-1/2"1/2"1/2"SINGLE COMPARTMENT SINK - ELKAY MODEL LR-1918 WITH ELKAY LK100OCR FAUCET, LK-35 DUO-STRAINER, 1/2" BALL STOPS AND 1-1/2" P-TRAP. CONDENSATE DRAIN LINE DOMESTIC COLD WATER PIPING DOMESTIC HOT WATER PIPING ROOF DRAIN LEADER PIPING PRESSURE REDUCING VALVE EQUIPMENT SYMBOL PLAN NOTE FC 1 1 GAS PIPING VENT LINE PIPING SOIL OR WASTE PIPING DESCRIPTION CLEANOUT TO GRADE WALL CLEANOUT CLEANOUT VENT THRU ROOF VENTV VTR COTG WCO CO SYMBOL SYMBOL GATE VALVE BALL VALVE DESCRIPTION ROOF DRAIN OVERFLOW PIPING FURNACE CONDENSING UNIT PIPE DROP PIPE RISE REFER TO SITE PLAN FOR CONTINUATION. RISE 20" DIA. RETURN DUCT UP THRU FLOOR AND CONNECT TO RETURN AIR PLENUM ABOVE. COORDINATE WITH PIPING. 1" COLD WATER SERVICE LINE TO BUILDING. REFER TO SITE PLAN FOR CONT. RISE 1" COLD WATER LINE UP AND CONNECT TO PRV STATION ABOVE. REFER TO DETAIL J/P2.1 FOR TYPICAL PIPING CONNECTIONS. REFER TO WASTE AND VENT RISER DIAGRAM A/P2.1 FOR COMPLETE PIPE SIZING AND CONNECTIONS. INVERT. ELEV 97'-0" 2" V 2" V S-1 L-1 DF-1 TP-1 FD-1 FD-1WC-1 WC-1 2" V FD-1 JS-12" V 4" COTG 2" V 2" W 2" W 2" W 4" W 4" W 4" W 2" W 2" W 1/2" HOT AND COLD WATER LINES (PEX) BELOW FLOOR WITH 3/4" THICK RUBBER PIPE INSULATION. RISE 1/2" HOT AND COLD WATER LINES UP IN PLUMBING CHASE ABOVE. REFER TO SHEET P1.1 FOR CONTINAUTION. GAS SERVICE LINE BY LOCAL GAS COMPANY. 4" W 4" W 2" W 2" W A A B BC CD D E E 66 55 44 33 22 11 RISE GAS LINE UP TO METER. SEE SHEET P1.1 FD-1 1/2" COLD WATER LINE FROM TRAP PRIMER TO FLOOR DRAIN. REFER TO DETAIL D/P2.1 FOR TYPICAL INSTALLATION. TP-1 L-1 1/2" COLD WATER LINE FROM TRAP PRIMER TO FLOOR DRAIN. REFER TO DETAIL D/P2.1 FOR TYPICAL INSTALLATION. Engineered Systems Associates PHONE: 1355 EAST CENTER POCATELLO, IDAHO 83201 ESA JOB NUMBER: FAX:(208) 233-0529 (208) 233-0501 EMAIL:esa@engsystems.com 23005 G D AH S P-18184 T A D I A V D S DT E O L. I H NA F S R E PROF N E SGI E ERT AISONL E NEO I R E EN 3/14/2023 PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 4/ 2 0 / 2 0 2 3 8 : 2 5 : 0 6 A M 2 3 0 0 5 B E E H I V E F C U ( M & P ) _ d e t a c h e d. r v t P1.0 19035 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . PL U M B I N G F O U N D A T I O N P L A N February 2023 A N E W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 M JENSEN D SUDWEEKS SCALE:1/4" = 1'-0" PLUMBING FOUNDATION PLAN 1 ADDENDUM #4 4/21/23 1 S-1 DF-1 L-1 WC-1 WC-1 L-1 FD-1 WF-1 OF-1 RD-1 DROP 3" ROOF DRAIN LINE DOWN COLUMN TO BELOW GRADE AND EXTEND OUT TO STORM SEWER. REFER TO SITE PLAN FOR CONTINUATION. REFER TO ELECTRICAL DRAWINGS FOR HEAT TRACE IN DRAIN LINE. FD-1 FD-1 JS-1 2" VTR FD-1 4" VTR 2" VTR RISE 1" COLD WATER SERVICE LINE UP AND CONNECT TO PRV STATION. REFER TO DETAIL J/P2.1 F 1 F 2 COTG GAS METER BY LOCAL GAS COMPANY. SIZE FOR 210,000 BTU WITH 0.5 psi DISCHARGE PRESSURE. CONTRACTOR TO PROVIDE ROOF COVER AS REQUIRED BY GAS COMPANY. WH-1 CU 1 CU 2 CONNECT 3/4" GAS LINE TO EACH FURNACE. REFER TO DETAIL E/P2.1 FOR TYPICAL CONNECTION. 1" CW 3/4" HW 3/4" HW 2" V 2" VSEE SHEET M1.2 SEE SHEET M1.2 1/2" CW 1" CW 3/4" CW 3/4" HW 2" W 1 1/2" W & CO 1" CW 1/2" HW 3/4" CW 1 1/2" W 1 1/2" W 1/2" HW 1/2" CW PROVIDE 1/2" CW LINE WITH SHUT-OFF VAVLE FOR FUTURE ICE MAKER CONNECTION. LOCATE PIPING AT FLOOR OF CABINET. RP-1 HB-1 AA BB BB CC CCA A B BC CD D E E 66 5 4 3 2 11 3.5 1.5 4.8 TP-1 TP-1 DROP 3/4" CD LINE DOWN IN WALL. CONNECT TO P-TRAP OF LAVATORY WITH 'DISHWASHER' TYPE CONNECTION. FC 1A 3/4" FC 1B DRIVE-THRU 106 OFFICE 1 104 MANAGER 103 MAIN LOBBY 102 OFFICE 3 115 OFFICE 2 113 MAIN LOBBY 102 HALLWAY 108 BREAK 107 JAN./STOR. 112 TOILET 118 TOILET 117I.T. 116 MECH. 111 VESTIBULE 101 Engineered Systems Associates PHONE: 1355 EAST CENTER POCATELLO, IDAHO 83201 ESA JOB NUMBER: FAX:(208) 233-0529 (208) 233-0501 EMAIL:esa@engsystems.com 23005 G D AH S P-18184 T A D I A V D S DT E O L. I H NA F S R E PROF N E SGI E ERT AISONL E NEO I R E EN 3/14/2023 PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 3/ 2 4 / 2 0 2 3 1 0 : 3 0 : 0 8 A M 2 3 0 0 5 B E E H I V E F C U ( M & P ) _ d e t a c h ed . r v t P1.1 19035 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . PI P I N G F L O O R P L A N February 2023 A N E W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 M JENSEN D SUDWEEKS SCALE:1/4" = 1'-0" PIPING FLOOR PLAN 1/2" HOT & COLD WATER LINES (PEX) BELOW FLOOR WITH RUBBER PIPE INSULATION. S-1 L-1 L-1 WC-1WC-1 3/4" 1/2" 1" 3/4" 3/4" WH-1 PRV STATION. REFER TO DETAIL J/P2.1. SEE DETAIL F/P2.1 1" SERVICE LINE TO BUILDING. REFER TO SITE PLAN FOR CONT. JS-1 1/2" S-1 2" W 4" W DF-1 L-1 L-1FD-1 WC-1 FD-1 FD-1 2" W 2" W 2" V CO 4" W 4" W 1-1/2" V 2" V 4" VTR 2" V 2" W CO JS-1 CO 2" V 2" VTR WC-1 CO FD-1 2" V 2" VTR 4" W 4" W DF-1 1" 1/2" 1" 1/2" 1/2" CO CO COTG 2" V 2" V 2" V 1-1/2" V 1-1/2" V 2" W 2" W 3/4" HB-1 3/4" VENT THRU METAL ROOF DETAIL ROOF PLAN OF BASE CWATER PIPING DIAGRAMBWASTE AND VENT RISER DIAGRAMA TRAP PRIMER DETAILD GAS LINE CONNECTION DETAILE WATER HEATER PIPING DIAGRAMF DX COIL CONDENSATE DRAIN DETAILG CONDENSATE DRAIN PIPING DETAILKWATER PRESSURE REDUCING STATION DETAILJCLEAN OUT DETAILS FLOOR CLEANOUT (FCO)CLEANOUT TO GRADE (COTG) WALL CLEANOUT (WCO) H PANEL METAL ROOF BASE CORROSION RESISTANT AROUND PERIPHERY SEALANT UNDER AND BETWEEN TRUSSES FROM CEILING THRU ROOF GALVANIZED STEEL PIPE FLASHINGS SHALL BE "BUILDEX DEKTITE" OR APPROVED FASTENERS EQUAL AS REQUIRED BY MANUFACTURER. NO SCALE CLAMP STACK TO UNISTRUT NOTE: OF BASE ATTACH UNISTRUT STACK SELF-DRILLING PANEL METAL ROOF TO PIPE SIZE RUBBER CONE CUT ALUMINUM BASE NO SCALENO SCALE NO SCALE MOUNT IN ACCESSIBLE LOCATION CONCRETE FILL WATERPROOF MEMBRANE WHERE REQUIRED HORIZONTAL RUN IN PIPE 12" MIN. TO SLAB STRUCTURAL BREAKING PORTS AIR GAP VACUUM FIXTURE NEAREST FLOW TO FLOOR DRAIN OUTLET TO P-TRAP CEMENT BED FLOORING IF APPLICABLE 1/2" PEX TRAP PRIMER BALL TYPE SHUT-OFF VALVE 6" V E R T I C A L 18" MAX. DRIP LEG SAME SIZE AS DROP NO SCALE GROUND JOINT MANUAL MAIN SHUT-OFF VALVE CASING EQUIPMENT FLEXIBLE GAS CONNECTOR. UNION 3/4" MAIN. SEE DROP FROM PLAN FOR SIZE NO SCALE NO SCALE 3/4" MIN. SIZE 3" ' M I N . 1/ 2 " NOTE: MANUFACTURED 'EZTRAP' IS ACCEPTABLE. DX COOLING COIL VACUUM BREAKER OPEN TO ATMOSPHERE HOSE CLAMP TYPICAL 3/4" I.D. CLEAR FLEXIBLE HOSE RUN TO DRAIN SLOPE AT 1/4"/FT. NO SCALE SCHEDULE 40 PVC EXHAUST PIPING SCHEDULE 40 PVC INTAKE VENT PIPINGFULLY CASED COOLING COIL CONNECTIONS DX COOLING COIL COOLING COIL COND. DRAIN NOTE: 3/4"FURNACE CONDENSATE DRAIN FURNACE DO NOT RUN CONDENSATE DRAIN WILL ALLOW ACCESS TO FURNACE COMPONENTS AND FILTERS. PIPING IN FRONT OF FURNACE. THISRUN TO NEAREST FLOOR DRAIN 3/4" 1/2" VACUUM BREAKER TO ATMOSPHERE GAS LINE SHUTOFF VALVE DIRT LEG UNION FLEXIBLE HOSE CONNECTION TRAP - SEE DETAIL G/M2.1 NO SCALENO SCALE WASTE LINE FLOOR LINE FINISH GRADE 1'-0" 1/8 C.I. BEND FLOOR LINE WALL BRASS CLEANOUT PLUG WITH COUNTER SUNK HEAD 16" SQUARE CONC PAD TROWEL SMOOTH CLEANOUT AND ACCESS COVER. TOP OF COVER TO BE FLUSH WITH TOP OF FLOOR. BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. CLEANOUT SHOULD NOT BE LOCATED IN CARPETED AREA. 1/8 BEND IF CLEANOUT OCCURS AT END OF LINE. CAST IRON WASTE LINE. LENGTH TO SUIT. CHROME WALL COVER AND SCREW MAY EXTEND AS A WASTE OR VENT PLUGGED TEE WITH CLEANOUT BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. 1/8 CAST IRON BEND 1/8 CAST IRON BEND R 3/4" WATER HEATER ANCHOR RECIRC. PUMP AQUASTAT COLD WATER LINE HOT WATER LINE DIELECTRIC UNION (TYP) HEAT TRAP FITTING MTHERMOMETER DRAIN VALVE W/ THREADED HOSE CONNECTION PIPE FULL SIZE TO FLOOR DRAIN T&P RELIEF VALVE SIZED TO MATCH WATER HEATER AMTROL ST-5 EXPANSION TANK ELECTRIC WATER HEATER MIXING VALVE FOR TEMPERED WATER BALL VALVE (TYPICAL) HOT WATER RECIRC SYMMONS 7-200 (TYPICAL) BALL VALVE TO FIXTURES DIRT LEG TYP. UNION 3/4" DRAIN VALVE 5'-0" CONTRACTOR BY PLUMBING CONTRACTOR BY SITE UTILITIES CAP GRADE EXT WALL 36" COMBINATION PRESSURE REDUCING VALVE AND STRAINER. SET DISCHARGE AT 60 PSIG TRERICE 3-1/2" NO. 800, RANGE 0-TO-100 PSI RISE TO CEILING SPACE REDUCED PRESSURE BACKFLOW PREVENTER DRAIN VALVE CW LINE OUT FOR SPRINKLER SYSTEM WATER SUPPLY TO BUILDING DOUBLE CHECK VALVE BACKFLOW PREVENTER WITH BALL VALVES AND STRAINER 1'-0" MINIMUM CLEARANCE ABOVE FLOOR RISE VENTS THRU ROOF WITH CONCENTRIC KIT. SEE DETAIL F/M2.1 CO Engineered Systems Associates PHONE: 1355 EAST CENTER POCATELLO, IDAHO 83201 ESA JOB NUMBER: FAX:(208) 233-0529 (208) 233-0501 EMAIL:esa@engsystems.com 23005 G D AH S P-18184 T A D I A V D S DT E O L. I H NA F S R E PROF N E SGI E ERT AISONL E NEO I R E EN 3/14/2023 PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 3/ 2 4 / 2 0 2 3 1 0 : 3 0 : 0 8 A M 2 3 0 0 5 B E E H I V E F C U ( M & P ) _ d e t a c h ed . r v t P2.1 19035 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . PI P I N G D E T A I L S & D I A G R A M S February 2023 A N E W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 M JENSEN D HANSEN J FURN. FURN. CR CR CR J J CR J CR J J 6 4 3 1 2 ABDE 5 C AABBCC 1D-3 IP CAM 1 1D-3 IP CAM 1 1D-3 IP CAM 1 2 6D-5 1D-3 IP CAM 1 1D-3 IP CAM 1 1D-3 IP CAM 1 MANAGER 103 BREAK 107 OFFICE 1 104 MECH. 111 JAN./STOR. 112 DRIVE-THRU 106OFFICE 2 113 MAIN LOBBY 102 OFFICE 3 115 I.T. 116 TOILET 117 TOILET 118 VESTIBULE 101 1D-3 122" 1D-3 122" 1 1 IP CAMIP CAM 1D-3 IP CAM 1D-3 IP CAM 1 1 1D-3 122" IP CAM 1D-3 IP CAM 1 1D-3 IP CAM 1 1D-3 IP CAM 1 1D-3 IP CAM 1 1 2D-3 IP CAM 1 1D-3 IP CAM 2 2 3 3 2 3 2 3 2 3 2 1D-3 IP CAM 1 1D-3 IP CAM 1 1D-3 156"1 IP CAM 1 13053 STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP OFESSIONALENGIN EE R 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com Engineering Inc. Consulting Engineers PROJECT #: PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : SAM TEP 03/24/23 3/ 2 3 / 2 0 2 3 1 1 : 3 0 : 1 4 A M \ \ P A Y N E F I L E S E R V E R \ M a i n F i l e S t or a g e \ 2 0 2 3 \ B e e h i v e F C U R e x b u r g - 2 3 2 2 \ 1 0 _ W o r k i n g D r aw i n g s \ B e e h i v e F C U R e x b u r g _ S A M _ P a y n e . r v t E0.0 19035 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . EL E C T R I C A L S Y M B O L S & D E T A I L S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 2322 CIRCUITING & GENERAL SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION KEYED NOTE REFERENCE1 BRANCH CIRCUIT HOME-RUN TO PANEL INDICATED A-1,3,5 3/4"C.-6#12,1#12G QTY & SIZE OF EQUIPMENT GROUND CONDUCTOR QTY & SIZE OF NEUTRAL AND PHASE CONDUCTOR(S) SIZE OF CONDUIT A-1,3,5 3/4"C.-6#12,1#12G PANEL AND CIRCUIT DESIGNATIONS EQUIPMENT GROUNDING CONDUCTOR TICK MARKS NEUTRAL CONDUCTOR(S) PHASE AND/OR SWITCH-LEG CONDUCTOR(S) BRANCH CIRCUIT/FEEDER CONCEALED IN CEILING OR WALL BRANCH CIRCUIT/FEEDER CONCEALED UNDERGROUND OR FLOOR NEW EQUIPMENT, DEVICES, ETC. EXISTING EQUIPMENT, DEVICES, ETC. DEMOLITION EQUIPMENT, DEVICES, ETC. DETAIL # / SHEET REFERENCE1 / ES101 *25,000A CALCULATED AVAILABLE FAULT CURRENT AT EQUIPMENT(SEE POWER RISER) LIGHTING SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION PARKING AREA POLE LIGHT, SINGLE OR DOUBLE HEAD AS INDICATED ON DRAWINGS. REFER TO LIGHT POLE DETAIL FOR POLE INFORMATION. 2X4 FLUORESCENT OR LED FIXTURE 2X2 FLUORESCENT OR LED FIXTURE SURFACE MOUNTED FLUORESCENT OR LED FIXTURE STRIP FLUORESCENT OR LED FIXTURE WALL MOUNTED FLUORESCENT OR LED FIXTURE EXTERIOR WALL MOUNTED FIXTURE ROUND RECESSED FIXTURE SURFACE OR PENDANT FIXTURE LIGHT FIXTURE SUBSCRIPTS NL NIGHT-LIGHT(CONNECT TO UNSWITCHED LEG OF CIRCUIT) EXIT SIGN, WALL OR CEILING MOUNTING AS REQUIRED (SINGLE OR DOUBLE FACE) DIRECTIONAL CHEVRONS AS INDICATED; CONNECT TO UNSWITCHED LEG OF LIGHTING CIRCUIT THAT IS IN THE SAME AREA AS THE EXIT SIGNS. SHADED FIXTURE INDICATES AN EMERGENCY FIXTURE. PROVIDE WITH EMERG. BATTERY PACK OR CONNECT TO EMERGENCY POWER SYSTEM (WHERE APPLICABLE). CONNECT BATTERY PACK TO UNSWITCHED LEG OF LIGHTING CIRCUIT THAT SERVES THE SAME AREA AS THE EMERGENCY FIXTURE. PROVIDE WITH TEST LIGHT AND SWITCH. CEILING MOUNTED OCCUPANCY SENSOR, REFER TO OCCUPANCY SENSOR/SWITCH SCHEDULE FOR SENSOR TYPE AND ADDITIONAL INFORMATION. SWITCH MOUNTED OCCUPANCY SENSOR OR LOW VOLTAGE SWITCHPOD, REFER TO OCCUPANCY SENSOR/SWITCH SCHEDULE FOR TYPE AND ADDITIONAL INFORMATION. SINGLE-POLE SWITCH DUAL-LEVEL SWITCH, PROVIDE CONTROL OF FIXTURES TO ALLOW OCCUPANT TO REDUCE LIGHT LEVEL TO 50%. (SUBSCRIPT APPLIES TO BOTH SWITCHES) SWITCH SUBSCRIPTS 3 3-WAY SWITCH 4 4-WAY SWITCH D DIMMER SWITCH (COMPATIBLE W/ LOAD & LTG TYPES) K KEYED SWITCH F TIMER SWITCH (INTERMATIC MODEL EI400 SERIES) P PILOT LIGHTED SWITCH F1 LIGHT FIXTURE TYPE DESIGNATION S ### WALL OR CEILING MOUNTED EMERGENCY LIGHTING UNIT W/BATTERY PACK CONNECT TO UNSWITCHED LEG OF LIGHTING CIRCUIT THAT IS IN THE SAME AREA AS THE EMERGENCY LIGHT. LV LOW-VOLTAGE SWITCH (PER DWG'S) T THERMAL-OVERLOAD SWITCH M SWITCH SUPPLIED WITH EQUIPMENT, INSTALLED BY E.C. WP WEATHERPROOF 2P DOUBLE POLE, SINGLE THROW SWITCH GENERAL LIGHTING NOTES: A. SYMBOLS SHOWN ABOVE MAY NOT REPRESENT ALL LIGHT FIXTURES USED ON PROJECT, REFER TO LIGHT FIXTURE SCHEDULE FOR ACTUAL FIXTURE INFORMATION INCLUDING FIXTURE TYPE, LAMPING, MOUNTING AND ETC. B. JUNCTION BOXES FOR LIGHTING CIRCUITING ARE NOT SHOWN FOR CLARITY. THE E.C. IS RESPONSIBLE FOR PROVIDING AND INSTALLING ALL JUNCTION BOXES REQUIRED FOR CIRCUITING OF ALL LIGHT FIXTURES THAT ARE NOT LISTED FOR "THROUGH-BRANCH CIRCUIT WIRING". C. IN GENERAL ALL SWITCH-LEG CONDUCTORS MAY NOT BE SHOWN ON DRAWINGS; E.C. SHALL PROVIDE AND INSTALL CONDUCTORS AS REQUIRED TO ACHIEVE CONTROL SCHEMES INDICATED AND DESCRIBED ON DRAWINGS. INCLUDING ALL 0 - 10V DIMMING CONTROLS BETWEEN SWITCH AND FIXTURES. D. ALL BATTERY EXIT SIGNS AND EMERGENCY LIGHTING TO BE CONNECTED TO THE UNSWITCHED LEG OF THE LIGHTING CIRCUIT IN THE AREA. ### F M POWER SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION ELECTRICAL SWITCHBOARD EQUIPMENT, (SEE POWER RISER AND PANEL SCHEDULES FOR ADDITIONAL INFORMATION) 'MSB' 'T##'DRY-TYPE TRANSFORMER, (SEE POWER RISER FOR ADDITIONAL INFORMATION) 'LA' ELECTRICAL PANELBOARD, (SEE POWER RISER AND PANEL SCHEDULES FOR ADDITIONAL INFORMATION) DISCONNECT SWITCH, SIZE/POLES/TYPE AS INDICATED TYPES: 1=NEMA 1, 3R=NEMA 3R, 4X=NEMA 4X30A/3P/3R FUSED DISCONNECT SWITCH, SIZE/POLES/TYPE AS INDICATED TYPES: 1=NEMA 1, 3R=NEMA 3R, 4X=NEMA 4X30A/3P/3R (30A FUSES) COMBINATION STARTER & FUSED DISCONNECT SWITCH, SIZE/POLES/TYPE AS INDICATED. TYPES: 1=NEMA 1, 3R=NEMA 3R, 4X=NEMA 4X J JUNCTION BOX CR = CORD REEL; SEE DRAWINGS FOR INFORMATION CD = CORD DROP; SEE DRAWINGS FOR INFORMATION EQUIPMENT CONNECTION; COORDINATE CONNECTION WITH EQUIPMENT PRIOR TO ROUGH-IN MOTOR CONNECTION POWER AND/OR DATA SERVICE POLE FLOORBOX WITH POWER ONLY (SEE FLOORBOX SCHEDULE FOR ADDITIONAL INFORMATION) PUSHBUTTON STATION FLOORBOX WITH POWER AND DATA(SEE FLOORBOX SCHEDULE FOR ADDITIONAL INFORMATION) FB# FB# SPECIAL RECEPTACLE (COORDINATE NEMA TYPE WITH EQUIP.) (REFER TO PANEL SCHEDULES FOR AMPS) CEILING MOUNTED DUPLEX RECEPTACLE (COORDINATE PLACEMENT WITH CEILING EQUIPMENT PRIOR TO ROUGH-IN) DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT GFCI-TYPE DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT DOUBLE-DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT GFCI-TYPE DOUBLE-DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT. RECEPTACLE AND EQUIPMENT SUBSCRIPTS AC ABOVE COUNTER WP WEATHERPROOF (UL LISTED WEATHER-RESISTANT) 42"MOUNTING HEIGHT AFF OR AFG IG ISOLATED GROUND S SURGE-PROTECTION TYPE REF REFRIGERATOR W WASHING MACHINE D DRYER (30A-240V RATED RECPT.) M MICROWAVE HVAC THERMOSTAT OR SENSOR; PROVIDE & INSTALL BACKBOX,3/4" CONDUIT AND CONDUCTORS TO ASSOCIATED HVAC UNIT. COORDINATE EXACT LOCATION & SIZE AND NUMBER OF CONDUCTORS WITH M.C. T SOR 30A/3P/3R SIZE 1 (30A FUSES) SMALL EXHAUST FAN CONNECTION TV 120V RECEPT. FOR TV; VERIFY HEIGHT WITH ARCH. DRAWINGS & ELEVATIONS USB 120V RECPT. WITH USB CHARGING PORTS EWC ELECTRIC WATER COOLER; (SEE DETAIL. RECPT. SHALL BE ACCESSIBLE, DO NOT MOUNT BEHIND HOUSING.) DISP GARBAGE DISP. (UNDER SINK) DW DISHWASHER (COORDINATE W/ MILLWORK, INSTALL PER NEC 422.16(B)(2)). M/R MICROWAVE/RANGE HOOD (COORDINATE W/ MILLWORK) R ELECTRIC RANGE (50A-240V RATED RECPT.) GENERAL SPECIAL SYSTEM NOTES: A. ALL DEVICES SHOWN AT OR NEAR MILLWORK/CASEWORK SHALL BE COORDINATED WITH THE ARCHITECTURAL ELEVATION DRAWINGS AND MILLWORK INSTALLER TO INSURE PROPER MOUNTING HEIGHTS. CONTRACTOR SHALL ADJUST DEVICES AS NECESSARY IN ORDER TO POSITION DEVICES SUCH THAT THEY WILL NOT FALL BEHIND MILLWORK, CABINETS OR BE DIRECTLY ABOVE SINKS OR MIDWAY BETWEEN TILEWORK/WALL OR WAINSCOATING, ETC. B. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL A GFCI TYPE RECEPTACLE FOR ALL RECPTACLES SHOWN IN TOILET RMS, BATHROOMS, KITCHENS/SERVING AREAS, ROOFTOP, OUTDOORS OR WITHIN 6FT OF ANY SINK, BASIN, TUB OR FLOOR SINK AND ALL OTHER AREAS DEFINED BY THE NEC. SPECIAL SYSTEMS SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION DATA OUTLET; _= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW)_D-X TELEPHONE OUTLET; _= # OF TELEPHONE CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW) _T-X TELEPHONE/DATA OUTLET; _= # OF TELEPHONE/DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW) _T/_D-X CEILING MOUNTED DATA OUTLET; _= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW) _D-X A. COMMUNICATIONS CABLES SHALL HAVE BENDS NO GREATER THAN 90 DEG. B. CONDUITS FOR COMMUNICATIONS CABLING SHALL HAVE A MAXIMUM BEND RADIUS NOT MORE THAN 10X THE DIAMETER OF THE CONDUIT. C. ALL COMMUNICATIONS CONDUITS SHALL BE TERMINATED WITH AN INSULATED NON-METALLIC BUSHING AT BOTH ENDS. D. COMMUNICATIONS CONDUITS SHALL HAVE NO MORE THAN (2) 90'S WITHOUT A PULLBOX. PULL BOXES SHALL BE LOCATED IN ACCESSIBLE LOCATIONS AND SHALL BE SIZED AT LEASED 12X THE LARGEST CONDUIT DIAMETER IN LENGTH AND MIN, 4" DEEP AND 8" WIDE. E. IT SHALL BE THE RESPONSIBILITY OF THE E.C. TO INSURE THAT THE PATHWAY FOR THE DATA CABLING DOES NOT CREATE CABLE LENGTHS TO EXCEEDS THE LENGTH OF 295FT FROM OUTLET TO PATCH PANEL, THIS INCLUDES SERVICE LOOPS AND PATCH CORDS. F. WHERE CABLE TRAY IS UTILIZED IN THE PROJECT. COMMUNICATION CONDUITS ENDING AT THE CABLE TRAY SHALL EXTEND 1" OVER THE SIDE INTO THE TRAY. GENERAL SPECIAL SYSTEM NOTES: RECESSED WALL MOUNTED AV/TV ENCLOSURE, (SEE NOTE 2 BELOW) HUBBELL ENCLOSURE# NSAV62M W/ COVER# NSAV6C, (1) POWERKIT HBL#NSOKPS, (1) DATA PLATE W. TERMINATIONS. MOUNT 5'-0" AFF; FIELD COORDINATE WITH TV LOCATION. E.C. SHALL INSTALL 1 1/4"C FROM DATA COMPARTMENT TO NEAREST ACCESSIBLE CEILING SPACE. INSTALL DATA CABLING AND TERMINATIONS AS INDICATED ON DRAWINGS. LARGE CAPACITY 2-GANG AV BOX, (SEE NOTE 2 BELOW) HUBBELL# HBL260 WITH 2-GANG MUDRING; PROVIDE 2-GANG DECORA COVER PLATE W/ (1) DATA INSERT (LEVITON P/N: 4164*-*) (1) BRUSH PASSTHROUGH INSERT (LEVITON P/N: 41075-DB*). INSTALL 1 1/2" CONDUIT FROM BOX TO ABOVE ACCESSIBLE CEILING. INSTALL DATA CABLING AND TERMINATIONS AS INDICATED ON DRAWINGS. TV AV _D-X _D-X SPECIAL SYSTEMS NOTES: 1. UTILIZE 4 11/16" DEEP BOX WITH REQUIRED MUDRING AND CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING OR DATA RACK, TERMINATE WITH INSULATED THROAT BUSHING. PROVIDE QTY OF CABLES INDICATED FROM OUTLET TO NEAREST TELE/DATA ROOM. SEE DWGS FOR ADDITIONAL INFORMATION. UTILIZE J-HOOKS 3FT ON CENTER FOR SUPPORT OF CABLING WHERE CABLE TRAY IS NOT INSTALLED/SPECIFIED. 2. CONDUIT SIZE ('X' FROM ABOVE); 2=1/2", 3=3/4", 4=1", 5=1-1/4", 6=1-1/2" 3. BLANK (NO LABEL) = 4-11/16" DEEP BOX WITH REQUIRED MUDRING AND 1" CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING OR TO DATA RACK, TERMINATE WITH INSULATED THROAT BUSHING, PROVIDE PULL STRING. (UNLESS OTHERWISE NOTED) WALL PATHWAY SYSTEM; STI FIRESTOP EZ-PATH SERIES INSTALL THROUGH WALL ABOVE ACCESSIBLE CEILING, FIELD VERIFY EXACT LOCATION TO AVOID CONFLICT WITH OTHER TRADES AND UTILITIES. PROVIDE ALL REQUIRE MOUNTING HARDWARE AND ETC. FOR COMPLETE INSTALLATION. EPF2 = FIRE RATED, EZ-PATH SERIES 22 EPF3 = FIRE RATED, EZ-PATH SERIES 33 EPF4 = FIRE RATED, EZ-PATH SERIES 44 EP3 = NON-FIRE RATED, EZ-PATH 33NEZ SERIES ### FB# _D-X MULTI-SERVICE FLOORBOX; SEE FLOORBOX SCHEDULE FOR ADDITIONAL INFORMATION. _= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW) P 1PH 2/C 3/C 3P 3PH 3W 4W AC ADA AFF AFG AIC AL A or AMP ANN AP ATS AV AWG BFG C CATV CB CCTV CKT C CP CT CU DS EA E.C. EM EMT ENT EPO EQUIP EX FA FACP FLA FMC GND G.C. GEN GFI GFP HD HID HOA HP HPS HV HZ IG IMC J-BOX ABBREVIATIONS SINGLE POLE SINGLE-PHASE TWO-CONDUCTOR THREE-CONDUCTOR THREE POLE THREE-PHASE THREE-WIRE FOUR-WIRE ABOVE COUNTER AMERICANS WITH DISABILITIES ACT ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMPERE INTERRUPTING CAPACITY ALUMINUM AMPERE ANNUNCIATOR ACCESS POINT (WIRELESS DATA) AUTOMATIC TRANSFER SWITCH AUDIO VISUAL AMERICAN WIRE GAGE BELOW FINISHED GRADE CEILING MOUNTED CABLE TELEVISION CIRCUIT BREAKER CLOSED CIRCUIT TELEVISION CIRCUIT CONDUIT CONTROL PANEL CURRENT TRANSFORMER COPPER DISCONNECT SWITCH EACH ELECTRICAL CONTRACTOR EMERGENCY ELECTRICAL METALLIC TUBING ELECTRICAL NONMETALLIC TUBING EMERGENCY POWER OFF EQUIPMENT EXISTING FIRE ALARM FIRE ALARM CONTROL PANEL FULL LOAD AMPS FLEXIBLE METAL CONDUIT GROUND GENERAL CONTRACTOR GENERATOR GROUND FAULT CIRCUIT INTERRUPTER GROUND FAULT PROTECTION HEAVY DUTY HIGH INTENSITY DISCHARGE HAND-OFF-AUTOMATIC HORSE POWER HIGH PRESSURE SODIUM HIGH VOLTAGE HERTZ ISOLATED GROUND INTERMEDIATE METAL CONDUIT JUNCTION BOX V KVA kW kWh LED LFMC LFNC LTG LV MAX M.C. MCA MCB MCC MDP MH MIN MLO MOCP NA NC NEC NEMA NFPA NIC NL NO NTS OC OH DR OL PB P PNL PT PTZ QTY RCP RMC RNC SCA SCBA SF SPD SPEC SWBD SWGR TL TP TTB TV TYP UG UPS V VA V.I.F. VFD W/ W/O WP XFMR KILOVOLT KILOVOLT AMPERE KILOWATT KILOWATT HOUR LIGHT EMITTING DIODE LIQUID TIGHT FLEXIBLE METAL CONDUIT LIQUID TIGHT FLEXIBLE NONMETALLIC CONDUIT LIGHTING LOW VOLTAGE MAXIMUM MECH. CONTRACTOR MINIMUM CIRCUIT AMPS MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MAIN DISTRIBUTION PANEL MANHOLE MINIMUM MAIN LUGS ONLY MAXIMUM OVERCURRENT PROTECTION NOT APPLICABLE NORMALLY CLOSED NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NATIONAL FIRE PROTECTION ASSOCIATION NOT IN CONTRACT NIGHT LIGHT NORMALLY OPEN NOT TO SCALE ON CENTER OVERHEAD DOOR OVERLOAD PUSHBUTTON PHASE PANEL POTENTIAL TRANSFORMER PAN/TILT/ZOOM QUANTITY REFLECTED CEILING PLAN RIGID METAL CONDUIT RIGID NONMETALLIC CONDUIT SHORT CIRCUIT AMPS STANDARD COLOR BY ARCHITECT SQUARE FOOT (FEET) SURGE PROTECTION DEVICE SPECIFICATION SWITCHBOARD SWITCHGEAR TWIST LOCK TWISTED PAIR TELEPHONE TERMINAL BOARD TELEVISION TYPICAL UNDERGROUND UNINTERRUPTIBLE POWER SUPPLY VOLTS VOLT AMPERE VERIFY IN FIELD VARIABLE FREQUENCY DRIVE WITH WITHOUT WEATHERPROOF TRANSFORMER • ELECTRICAL CONTRACTOR SHALL REFER TO THE MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL MECHANICAL EQUIPMENT AND ELECTRICAL CONNECTIONS. • ELECTRICAL CONTRACTOR SHALL PROVIDE MINIMUM WORKING CLEARANCE AS PER NEC BEFORE INSTALLING ANY ELECTRICAL PANELS OR CABINETS. SEE ELECTRICAL EQUIPMENT CLEARANCE DETAIL. • INSTALL ALL LIGHT FIXTURES IN MECHANICAL ROOM AFTER THE MECHANICAL EQUIPMENT IS IN PLACE. ADJUST AS NECESSARY. PROVIDE CHAIN SUSPENSION KITS AS REQUIRED. • REFER TO ARCHITECTURAL REFLECTED CEILING PLAN(S) FOR EXACT FIXTURE LOCATIONS, CEILING TYPES, ETC. • ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONCRETE PADS AS REQUIRED FOR ALL ELECTRICAL EQUIPMENT. • CONFIRM EXACT LOCATIONS OF ALL TELEPHONE/DATA OUTLETS WITH OWNER PRIOR TO ROUGH-IN. • LOCATE SWITCHES, OUTLETS, ETC., SHOWN AT ROOM ENTRY DOORWAYS, AS CLOSE TO DOOR FRAME AS POSSIBLE, SO AS NOT RO INTERFERE WITH ROOM CABINETS, ETC. PROJECT GENERAL NOTES: • SUPPORT ALL LIGHT FIXTURES INDEPENDENT OF CEILING. • ELECTRICAL CONTRACTOR SHALL OBTAIN ALL APPLICABLE PERMITS FOR WORK AND PAY ASSOCIATED FEES. • MAINTAIN 24" MIN. CLEARANCE FROM ALL COMMUNICATIONS CABLING AND ELECTRONIC BALLASTS. • UNLESS SPECIFICALLY INDICATED OTHERWISE, ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ANY SPECIAL SYSTEMS SUPPLIER/CONTRACTOR; DENTAL, MEDICAL, KITCHEN, SPECIALIZED EQUIPMENT, ETC. FOR THE EXACT ROUGH-IN REQUIREMENTS FOR THEIR EQUIPMENT. ALSO UNLESS INDICATED OTHERWISE, THE ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR FINAL ELECTRICAL CONNECTIONS TO ALL SPECIAL EQUIPMENT. • ALL CONDUIT/RACEWAY/CABLES TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. IF ANY SURFACE WORK IS NECESSARY, IT SHALL BE APPROVED BY THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION. • ELECTRICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND THOROUGHLY INVESTIGATE THE EXISTING CONDITIONS, AS THEY RELATE TO THE SCOPE OF WORK DESCRIBED. MAKE NECESSARY PROVISIONS IN THE BASE BID TO ADEQUATELY ACCOMMODATE THESE CONDITIONS. TYPICAL DEVICE MOUNTING HEIGHTS: GENERAL COORDINATION NOTE: GENERAL DETAIL NOTES: FINISH FLOOR 1' - 6'' THERMOSTAT OR SENSORVERIFY WITH M.C. PRIOR TO LIGHT SW. (OR AS NOTED) * 4' - 0'' * 3' - 6'' (OR AS NOTED) RECEPTACLE @ MILLWORK BACKSPLASH CA B . D I M E N S I O N S PE R A R C H . D E T A I L 6" CABINET *E.C. SHALL COORDINATE ALL DEVICE MOUNTING HGTS. AND EXACT LOCATION WITH ARCHITECTURAL INTERIOR ELEVATIONS REPORT CONFLICTS TO ARCHITECT **PRIOR TO ROUGH-IN** ROUGH-IN. TYPICAL FOR ALL DEVICES MOUNTED ABOVE COUNTER (ie C.O.'S, DATA, PHONE etc.) A. B. C. D. ALL MOUNTING HEIGHTS TYPICAL UNLESS NOTED OTHERWISE. COORDINATE OUTLET HEIGHTS WITH ARCHITECTS MILLWORK DWGS. TO INSURE THAT OUTLETS WILL NOT FALL BEHIND CABINETS, BACKSPLASHES, OR INTERFERE WITH WAINSCOTING, ETC. ALL SWITCHES AND THERMOSTATS TO BE MOUNTED AS CLOSE TO DOOR JAMS AS POSSIBLE. COORDINATE ALL DEVICES WITH ARCHITECTURAL PLANS AND DETAILS. COORDINATE LIGHT SWITCH & OUTLET HEIGHTS WITH ARCHITECTURAL WAINSCOTING AND OR TILE WORK SO AS NOT TO FALL MIDWAY IN THESE FINISHES. FIRE 6' - 8'' FIRE ALARM NOTIFICATION DEVICE FIRE MANUAL PULL STATION HANDLE SHALL BE BETWEEN 42" & 48" AFF CABINET RECEPT. TELE/DATA OUTLET TV OUTLET SECURITY & ACCESS CONTROL SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION PROVIDE ROUGH-IN FOR CARD REAADER WITH A 3/4" CONDUIT & PULL CORD FROM WIRING CHASE IN DOOR FRAME TO ABOVE NEAREST ACCESSIBLE CEILING SPACE. E.C. SHALL COORDINATE WITH ACCESS CONTROL CONTRACTOR. CR PROVIDE AND INSTALL A 3/4" CONDUIT & PULL CORD FROM WIRING CHASE IN DOOR FRAME TO ABOVE NEAREST ACCESSIBLE CEILING SPACE. E.C. SHALL ARRANGE A PRE- INSTALLATION MEETING WITH G.C. AND DOOR HARDWARE SUPPLIER TO COORDINATE EXACT PALCEMENT PRIOR TO ROUGH-IN. • PRIOR TO ROUGH IN E.C. SHALL HAVE A COORDINATION MEETING WITH SECURITY CONTRACTOR FOR REQUIRED ROUGH-IN FOR ALL SECURITY/ACCESS CONTROL EQUIPMENT. GENERAL SECURITY & ACCESS CONTROL NOTES: IDAHO POWER CO. ROCKY MOUNTAIN POWER CO. WWW.IDAHOPOWER.COM WWW.ROCKYMOUNTAINPOWER.NET CONTACT: CONTACT: SHELLEY MARTIN (208) 388-5872 DAN KUHL (503) 308-0233 OR DAN KUHL (503) 308-0233 dan.kuhl@evergreen-efficiency.com dan.kuhl@evergreen-efficiency.com UTILITY LIGHTING REBATES & INCENTIVES: IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PREPARE ALL REQUIRED APPLICATIONS AND INFORMATION REQUIRED TO PROVIDE THE OWNER WITH THE MAXIMUM AMOUNT OF REBATE DOLLARS FROM THE LOCAL UTILITY COMPANY. THE ELECTRICAL CONTRACTOR SHALL SUBMIT VERIFICATION OF THE UTILITY COMPANY PRE-APPLICATION APPROVAL PRIOR TO ORDERING ANY MATERIALS. VISIT THE FOLLOWING UTILITY CO. WEBSITES FOR INFORMATION: SCALE: 1/8" = 1'-0"1 SECURITY/ACCESS CONTROL & SOUND SYSTEM ROUGH-IN PLAN 1 E.C. SHALL PROVIDE REQUIRED ROUGH-IN AND CABLING FOR IP CAMERAS; PRIOR TO ROUGH-IN E.C. SHALL COORDINATE EXACT LOCATIONS WITH OWNER; SEE GENERAL NOTES FOR OWNER CONTACT INFORMATION. ALL IP CAMERA CABLING SHALL TERMINATE IN DEDICATED PATCH PANEL(S) IN DATA RACK. 2 E.C. SHALL PROVIDE REQUIRED ROUGH-IN INCLUDING BOX AND CONDUIT TO SECURITY SYSTEM HEAD-END EQUIPMENT AS DIRECTED BY SECURITY CONTRACTOR. E.C. SHALL COORDINATE SECURITY ROUGH-IN REQUIREMENTS WITH SECURITY CONTRACTOR PRIOR TO WORK; SEE GENERAL NOTES. 3 PROVIDE AND INSTALL A 120V CIRCUIT IN J-BOX ABOVE ACCESSIBLE CEILING. LABEL "ACCESS CONTROL POWER SUPPLY" FOR USE BY ACCESS CONTROL CONTRACTOR. UTILIZE NEAREST 120V RECEPTACLE CIRCUIT IN AREA. SOUND SYSTEM SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION VOLUME CONTROLLER E.C SHALL PROVIDE ROUGH-IN; BOX, MUDRING AND 1/2" C. WITH PULL STRING TO ACCESSIBLE CEILING OR SPEAKER; COORDINATE WITH SOUND SYSTEM CONTRACTOR. ZACH McCLEERY W/ ACS 208-571-7007. KEY NOTES:# 16'8'0" J J J J J J J 'METER EQUIP.' 1 2 FE1 FE1 FE1 FE1 WP WP WP WP WP FE2 3 3 3 3 WP WP WP 4 4 4 3 5 FLAG POLE 6 6 7 8 WP 4 6 6A-13 A-15 A-11 A-1 1"C.-3#10+1#10G TO I.T. ROOM A-4 1"C.-2#10+1#10G 9 10 9 A-12 9 9 A-2 3/4"C.-2#10+1#10G TTB A-13 (1) 1"C.,W/ PULL STRING FROM DATA RACK IN IT RM TO POLE LIGHT FOR SECURITY CAMERA. STUB INTO POLE BASE 11 11 1213 PRIVATE DRIVE N. 2 N D E . E. MOODY ROAD A-12 A-12 A-12 A-11 A-2 A-1 A-2 A-2 A-1 'A' A-2 A-1 14 4' - 0 M I N . 6" 25 ' - 0 ± UNDISTURBED OR COMPACTED EARTH POLE BASE WITH 4 #5 RE-BARS AND #3 TIES @ 12" O.C. 3000 PSI MIN. CONDUIT (PVC) 24" MIN. DEPTH. REFER TO PLAN. ANCHOR BOLTS TO SUIT POLE FINISHED GRADE POLE BASE COVER 4" SQUARE STRAIGHT STEEL POLE. POLE COLOR TO MATCH POLE LIGHT POLE LIGHT- SEE SCHEDULE 24" DIA. GFI, WP RECEPTACLE HAND HOLE FLAG POLE LIGHT - FE2 MOUNTED TO POLE INDICATE ON SITE PLAN - FIELD AIM AT FLAG AT NIGHT &CONNECT TO SEPERATE RELAY OF LCP FROM SITE LIGHTING RIGHT ANGLE ARM BRACKET 12 ' -0± TOP EDGE OF POLE BASE SHALL BE CHAMFERED 13053 STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP OFESSIONALENGIN EE R 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com Engineering Inc. Consulting Engineers PROJECT #: PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : SAM TEP 03/24/23 3/ 2 3 / 2 0 2 3 1 1 : 3 0 : 1 6 A M \ \ P A Y N E F I L E S E R V E R \ M a i n F i l e S t or a g e \ 2 0 2 3 \ B e e h i v e F C U R e x b u r g - 2 3 2 2 \ 1 0 _ W o r k i n g D r aw i n g s \ B e e h i v e F C U R e x b u r g _ S A M _ P a y n e . r v t E0.1 19035 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . EL E C T R I C A L S I T E P L A N MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 2322 SCALE: 3/32" = 1'-0"1 ELECTRICAL SITE PLAN NORTH 16'8'0"SCALE: NONEAPOLE LIGHT DETAIL KEY NOTES:# 1 NEW UTILITY COMPANY TRANSFORMER, PAD AND VAULT. PAD AND VAULT PROVIDED AND INSTALLED BY E.C PER RMP REQUIREMENTS. SEE GENERAL NOTES AND POWER RISER FOR ADDITIONAL INFORMATION. 2 METERING EQUPMENT MOUNTED ON BUILDING. SEE POWER RISER FOR ADDITIONAL INFORMATION. 3 RECEPTACLE MOUNTED TO MONUMENT/POLE LIGHT TO BE CONTROLLED BY WALL SWITCH LOCATED IN BUILDING. FIELD VERIFY SWITCH LOCATION WITH OWNER PRIOR TO ROUGH-IN. 4 RECEPTACLE MOUNTED FLUSH IN EXTERIOR SOFFIT FOR CHRISTMAS LIGHTING; FIELD COORDINATE EXACT LOCATION WITH OWNER. CONTROL VIA SWITCH LOCATED PER OWNER. LABEL SWITCH ACCORDINGLY. 5 JUNCTION BOX FOR POWER AND DATA CONNECTION TO MONUMENT SIGN; COORDINATE EXACT LOCATION WITH SIGN INSTALLER. PROVIDE (2) 1" CONDUITS (1) FOR POWER ELECTRICAL PANEL AND (1) FOR DATA TO TTB. 6 E.C. SHALL PROVIDE AND INSTALL HEAT TAPE IN ALL GUTTERS AND DOWNSPOUTS; INSTALL PER MANUFACTURERS RECOMMENDATIONS. ALL INDIVIDUAL HEAT-TRACE CIRCUIT/CABLE RUNS SHALL NOT EXCEED 150FT IN LENGTH. REFER TO ARCHITECTURAL DRAWINGS AND ELEVATIONS FOR ADDITIONAL GUTTER AND DOWNSPOUT LENGTHS AND LOCATIONS. FIELD MEASURE ALL HEAT-TRACE LENGTHS PRIOR TO ORDERING AND CABLE, ETC. ROUTE ALL CIRCUITS THROUGH HEAT-TRACE CONTACTOR. PROVIDE ALL COMPONENTS FOR A COMPLETE INSTALLATION INCLUDING BUT NOT LIMITED TO; CLIPS, END SEALS, AND ETC. PER MANUFACTURER'S INSTALLATION INSTRUCTION. UTILIZE RAYCHEM ICESTOP GM-1XT SERIES SELF-REGULATING HEATING CABLE. 7 PROVIDE HEAT TRACING OF ROOF AND OVERFLOW DRAINS. COIL HEAT TAPE AROUND ROOF AND OVERFLOW DRAINS AND EXTEND INTO DRAIN. WHERE DRAIN PIPES EXTEND INTO UNCONDITIONED SPACE, HEAT TRACE SHALL EXTEND DOWN PIPE TO CLEAN-OUT LOCATED AT FINISHED GRADE. EXACT TAPE LENGTH TO BE DETERMINED IN FIELD. UTILIZE RAYCHEM 120V, GM-1XT CABLE. PROVIDE ALL COMPONENTS FOR A COMPETE INSTALLATION INCLUDING BUT NOT LIMITED TO: POWER CONNECTOR, JUNCTION BOX, CABLE END SEALS, CABLE SUPPORT CLIPS, ETC. COORDINATE ALL ROOF PENETRATIONS WITH ROOF CONTRACTOR TO PROVIDE PROPER FLASHING AND SEALING OF PENETRATIONS. UTILIZE GFEPD TYPE CIRCUIT BREAKERS FOR ALL HEAT TRACE CIRCUITS. 8 PROVIDE (1) 2" CONDUIT STUBBED TO LANDSCAPE AREA FOR IRRAGATION CONTROLS; COORDINATE WITH LANDSCAPE CONTRACTOR PRIOR TO INSTALLATION FOR STUB LOCATION. 9 CIRCUIT VIA 16-RELAY LIGHTING CONTROL PANEL (LCP) WITH ASTRONOMICAL TIME CLOCK, LEVITON ZMAX # R24BD-L16 OR EQUAL, LOCATE ADJACENT TO PANEL. PROGRAM PER OWNERS DIRECTION. PROVIDE UN-SWITCH LEG FROM LINE SIDE OF LIGHTING CONTROL RELAYS FOR CONNECTION TO NIGHT-LIGHT/EMERGENCY FIXTURES WHERE REQUIRED. 10 PROVIDE A SEPARATE SWITCH-LEG FROM A DEDICATED RELAY OF THE LIGHTING CONTROL PANEL (LCP) FOR SEPARATE CONTROL OF FLAG POLE LIGHT. FLAG POLE LIGHT AND SITE LIGHTING SHALL BE SEPARATELY CONTROLLED. 11 PROVIDE AND INSTALL IN-GRADE, FIBERGLASS J-BOX WITH LID LABELED "ELECTRICAL" NEXT TO POLE BASE OR NEAREST LANDSCAPE AREA TO LIMIT THE NUMBER OF CONDUITS INTO POLE BASE TO TWO(2). INSTALL LID FLUSH WITH FINISHED GRADE AND PROVIDE CRUSHED GRAVEL IN BOTTOM FOR DRAINAGE. J-BOX SHALL BE INSTALLED IN LANDSCAPE AREAS ONLY, NOT SUBJECT TO VEHICLE TRAFFIC. 12 NEW UNDERGROUND PRIMARY CONDUIT PROVIDED AND INSTALLED BY E.C. CONDUCTORS BY ROCKY MOUNTAIN POWER (RMP) COORDINATE CONDUIT REQUIREMENTS AND STUB LOCATION WITH RMP PRIOR TO INSTALLATION; SEE GENERAL NOTES AND POWER RISER DIAGRAM FOR ADDITIONAL INFORMATION. 13 (1) 4" CONDUIT FOR TELECOMMUNICATIONS SERVICE TO BUILDING AND (1) 2" CONDUIT FOR CABLE TV SERVICE TO BUILDING. STUB CONDUITS TO LOCATIONS AS SPECIFIED BY LOCAL TELEPHONE AND CABLE TV PROVIDERS, PROVIDE WITH PULL-STRING. COORDINATE WITH LOCAL UTILITIES AS INDICATED IN GENERAL NOTES 14 NEW UNDERGROUND SECONDARY; SEE POWER RISER FOR ADDITIONAL INFORMATION. A. THESE PLANS HAVE BEEN PREPARED WITHOUT UTILITY COMPANY COMMENTS. THE E.C. SHALL VERIFY THE EXACT REQUIREMENTS FOR THE ELECTRIC AND TELEPHONE SERVICES WITH THE UTILITY COMPANY REPRESENTATIVES AND PROVIDE ALL WORK AND PAY ALL COSTS FOR A COMPLETE AND OPERATING SYSTEM, AS DIRECTED BY THE GOVERNING UTILITIES. GENERAL NOTES: #2 71 -95- F TL- 15 UNENCA SE D SAFE FILE NO . 1 73 -10 6 R EV. 1 WDD WDD SPD SCD2 WD D S CD6 WD 1 WD 1 SCD6 WDD WDD W1R W1R LC WAC SCD6 6 4 3 1 2 ABDE 5 C AABBCCF8E F7E F8 FE5 FE5 FE5FE5 FE5 FE5NLFE5 FE5 NLFE5 F4F4 F4F4 F2 F2E F2 F2 F2 F1 F1 F1F1 F1 'LCP' F6 F6 F5 FE4E 8' -0" FX1 FX2 FX1 10' -0" FE3 6' -0" FE3 6' -0" A-19 A-17 A-3 1 F9F9F9 F10 F10 MANAGER 103 HALLWAY 108 MAIN LOBBY 102 I.T. 116 TOILET 117 TOILET 118 VESTIBULE 101 A-21 FE4 8' -0" SW-'a' SW-'b' SW-'a' SW-'b' SW-'b' BREAK 107 OFFICE 1 104 MECH. 111 JAN./STOR. 112 DRIVE-THRU 106 OFFICE 2 113 OFFICE 3 115 F1 FE4 9' -6" FE4 9' -6" NL NL 2 (TYP)F3 F3 F3 F3F3E 'A' A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES: KEY NOTES:# 1 CIRCUIT VIA 16-RELAY LIGHTING CONTROL PANEL (LCP) WITH ASTRONOMICAL TIME CLOCK, LEVITON ZMAX # R24BD-L16 OR EQUAL, LOCATE ADJACENT TO PANEL. PROGRAM PER OWNERS DIRECTION. PROVIDE UN-SWITCH LEG FROM LINE SIDE OF LIGHTING CONTROL RELAYS FOR CONNECTION TO NIGHT-LIGHT/EMERGENCY FIXTURES WHERE REQUIRED. 2 PROVIDE (2) SWITCH-LEGS FROM SEPARATE RELAY'S OF LIGHTING CONTROL PANEL TO CONTROL THE NIGHT-LIGHTS(NL) SEPARATELY FROM THE OTHER EXTERIOR LIGHTING. ALSO PROVIDE AN ADDITIONAL UN-SWITCHED LEG FOR POWER TO EMERGENCY BATTERY PACKS/FIXTURES. 13053 STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP OFESSIONALENGIN EE R 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com Engineering Inc. Consulting Engineers PROJECT #: PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : SAM TEP 03/24/23 3/ 2 3 / 2 0 2 3 1 1 : 3 0 : 1 8 A M \ \ P A Y N E F I L E S E R V E R \ M a i n F i l e S t or a g e \ 2 0 2 3 \ B e e h i v e F C U R e x b u r g - 2 3 2 2 \ 1 0 _ W o r k i n g D r aw i n g s \ B e e h i v e F C U R e x b u r g _ S A M _ P a y n e . r v t E1.0 19035 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . LI G H T I N G P L A N MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 2322 SCALE: 1/4" = 1'-0"1 LIGHTING PLAN NORTH 8'4'0" #2 71 -95- F TL- 15 UNENCA SE D SAFE FILE NO . 1 73 -10 6 R EV. 1 FB2 FB2 FB2 FB2 J J J J J MM T MM T MM T MM T MM T MM T MM T MM T TV EP 3 EP 3 EP 3 M M F F F F F F FURN. FURN. TV TV EP 3 J JJ T F- 1 T F-2 J 6 4 3 1 2 ABDE 5 C AABBCC 42" 42" AC M/42" ACAC AC WP 1 222 3 4 5 6 7 8 8 9 10 1111 1111 AC AC 3D-5 3D-4 1D-5 72" 3D-5 3D-4 3D-4 3D-4 2D-3 3D-4 3D-4 AC3D-4 AC 12 1D-3 13 4D-44D-4 2D-34D-4 3D-5 3D-5 3D-4 3D-4 1D-3 'METER EQUIP.' EH-1 F-2 F-1 CU-1 CU-2 WH-1 EF-3 EF-2 EF-1 EF-4 A-23,25 A-26,28 A-30 A-33,35 A-22A-40,41 A-37 A-39 A-51 A-53 A-49A-47 EWC A-36,38 1D-5 72" 1D-5 72" 2D-3 AC A-32 REF/42" A-14,16 A-18,20 A-34 1"C.-2#10+1#10G MANAGER 103 BREAK 107 OFFICE 1 104 MECH. 111 JAN./STOR. 112 HALLWAY 108 DRIVE-THRU 106 OFFICE 2 113 MAIN LOBBY 102 OFFICE 3 115 I.T. 116 TOILET 117 TOILET 118 VESTIBULE 101 14 TO PNL 'A' 4"C.-TO BLDG A-5 15 16 17 A-7 15 16 16 A-43 2D-3 DATA RACK TTB AC AC A-42,44 A-45 A-57,59 3/4"C.-2#10+1#10G 18 18 7 12 AC AC 3D-4 AC AC 'A' 3D-4 3D-4 19 19 19 19 19 A-24 A-27 FC-1b FC-1a RP-1 WP POWER FOR LANDSCAPE SPRINKLER CONTROLLER COORDINATE EXACT LOCATION WITH LANDSCAPE CONTRACTOR. A-29 20 A-23 A-31 A-29 14 A-27 A-29,31 13053 STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP OFESSIONALENGIN EE R 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com Engineering Inc. Consulting Engineers PROJECT #: PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : SAM TEP 03/24/23 3/ 2 3 / 2 0 2 3 1 1 : 3 0 : 2 0 A M \ \ P A Y N E F I L E S E R V E R \ M a i n F i l e S t or a g e \ 2 0 2 3 \ B e e h i v e F C U R e x b u r g - 2 3 2 2 \ 1 0 _ W o r k i n g D r aw i n g s \ B e e h i v e F C U R e x b u r g _ S A M _ P a y n e . r v t E2.0 19035 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . PO W E R / D A T A P L A N MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 2322 SCALE: 1/4" = 1'-0"1 POWER & SYSTEMS PLAN 8'4'0" NORTH KEY NOTES:# 1 CONNECTION TO "24-HR ATM" SIGN; CONNECT TO NEAREST 120V UN-SWITCHED POWER. SIGN PROVIDED BY BANK EQUIPMENT SUPPLIER, INSTALLED BY E.C. COORDINATE EXACT MOUNTING LOCATION WITH ARCHITECTURAL ELEVATION DRAWINGS. 2 CONNECTION TO "OPEN/CLOSED" SIGN; SIGN PROVIDED BY BANK EQUIPMENT SUPPLIER, INSTALLED BY E.C. SIGN SHALL BE CONTROLLED BY 2-POSITION SWITCH LOCATED IN DRIVE-THRU AREA. COORDINATE SWITCH WITH DIEBOLD. COORDINATE EXACT MOUNTING LOCATION WITH ARCHITECTURAL ELEVATION DRAWINGS. 3 (3) 2-POSITION SWITCHES FOR "OPEN/CLOSE" SIGNS; FIELD LOCATE SWITCHES PER OWNER DIRECTION. LABEL SWITCHES AS REQUIRED. 4 POWER CONNECTION TO DRIVE-THRU ATM MACHINE; COORDINATE CONDUIT STUB-UP LOCATION WITH BANK EQUIPMENT SUPPLIE AND SHOP DRAWINGS PRIOR TO ROUGH-IN. 5 PROVIDE AND INSTALL (1)4" PVC CONDUIT FROM DRIVE-THRU ATM TO BUILDING FOR ROUTING OF LOW-VOLTAGE CABLING; FIELD VERIFY STUB-UP LOCATION AT EQUIPMENT AND WITH-IN BUILDING WITH BANK EQUIPMENT SUPPLIER AND SHOP DRAWINGS PRIOR TO ROUGH-IN. 6 JUNCTION BOX FOR POWER CONNECTION TO DRIVE-UP DEPOSIT PROVIDED BY BANK EQUIPMENT SUPPLIER; INSTALLED AND CONNECTED BY E.C. COORDINATE WITH BANK EQUIPMENT SUPPLIER SHOP DRAWINGS PRIOR TO ROUGH-IN. 7 PROVIDE AND INSTALL (1) 1 1/2" CONDUIT FOR CUSTOMER VACUUM TUBE UNIT FROM TELLER AREA IN BUILDING; FIELD VERIFY STUB-UP LOCATIONS WITH BANK EQUIPMENT SUPPLIER AND SHOP DRAWINGS PRIOR TO ROUGH-IN. E.C. SHALL PROVIDE ANDI INSTALL (2) BELDEN 8241 CABLES FROM CCTV MONITOR AT CUSTOMER UNIT TO CCTV MATRIX SWITCHER AT TELLER AREA THEN FROM CCTV MATRIX SWITCHER TO OPERATOR VIDEO UNIT. 8 POWER FOR FUTURE VACUUM TUBE SYSTEM BLOWERS LOCATED IN CANOPY; FIELD VERIFY CONNECTION LOCATION AND REQUIREMENTS WITH BANK EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN. 9 PROVIDE (4) 1" CONDUIT CHASES FROM ABOVE ACCESSIBLE CEILING IN TELLER AREA TO ACCESSIBLE SPACE IN DRIVE-THRU CANOPY. COORDINATE CHASE LOCATIONS WITH DIEBOLD. 10 PROVIDE 4-GANG SWITCH BANK WITH (2) SINGLE-POLE SWITCHES FOR ON/OFF SWITCHING OF CCTV AT CUSTOMER DRIVE-THRU UNITS AND (2) BLANK FOR FUTURE DRIVE-THRU UNITS. PROVIDE CONDUIT(S) FROM SWITCH BANK TO CUSTOMER VACUUM TUBE UNIT CONDUIT STUB-UP LOCATION FOR ROUTING OF CABLING BY BANK EQUIPMENT SUPPLIER. COORDINATE PLACEMENT OF SWITCHES AND CONDUIT REQUIREMENTS WITH BANK EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN. 11 CONNECTION TO VACUUM TUBE SYSTEM BLOWERS LOCATED IN CANOPY; FIELD VERIFY CONNECTION LOCATION AND REQUIREMENTS WITH BANK EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN. 12 JUNCTION BOX FOR ALARM CONNECTION TO BANK EQUIPMENT PROVIDED BY BANK EQUIPMENT SUPPLIER; INSTALLED BY E.C. PROVIDE 3/4" CONDUIT TO BUILDING ALARM SYSTEM. COORDINATE WITH BANK EQUIPMENT SUPPLIER SHOP DRAWINGS PRIOR TO ROUGH-IN. 13 PROVIDE AND INSTALL (4) 2" CONDUIT SLEEVES FROM ACCESSIBLE CEILING SPACE OF DRIVE-THRU TO DATA RACK FOR ROUTING OF DATA AND SECURITY CABLING. FIELD VERIFY EXACT ROUTING, PROVIDE PULLSTING IN EACH SLEEVE. 14 DUPLEX RECEPTACLES FOR DRIVE-UP BANK EQUIPMENT, E.C. SHALL FIELD VERIFY EXACT ROUGH-IN LOCATIONS, MOUNTING HEIGHTS, ETC. WITH DRIVE-UP BANK EQUIPMENT SUPPLIER SHOP DRAWINGS PRIOR TO ROUGH-IN. REFER TO BANK EQUIPMENT ROUGH-IN NOTE. 15 CIRCUIT VIA 16-RELAY LIGHTING CONTROL PANEL (LCP) WITH ASTRONOMICAL TIME CLOCK, LEVITON ZMAX # R24BD-L16 OR EQUAL, LOCATE ADJACENT TO PANEL. PROGRAM PER OWNERS DIRECTION. PROVIDE UN-SWITCH LEG FROM LINE SIDE OF LIGHTING CONTROL RELAYS FOR CONNECTION TO NIGHT-LIGHT/EMERGENCY FIXTURES WHERE REQUIRED. 16 JUNCTION BOX FOR BUILDING MOUNTED SIGNAGE; FIELD VERIFY/COORDINATE EXACT LOCATION AND CONNECTION REQUIREMENTS WITH SIGN INSTALLER PRIOR TO ROUGH-IN. 17 PROVIDE AND INSTALL 18" WIDE BASKET TRAY ABOVE RACKS FOR ROUTING OF LOW VOLTAGE CABLING; PROVIDE ALL REQUIRED MOUNTING AND INSTALLATION HARDWARE FOR COMPLETE INSTALLATION. 18 PROVIDE POWER TO AUTOMATIC ADA DOOR; PROVIDE ALLREQUIRED ROUGH-IN AND CONNECTIONS FOR PUSH BUTTONS AND DOOR OPERATORS; FIELD VERIFY CONNECTIONS AND ROUGH-IN WITH DOOR INSTALLER. 19 THIS DEVICE SHALL BE BLACK IN COLOR WITH STAINLESS STEEL COVERPLATE. 20 DUPLEX RECEPTACLE FOR DRIVE-THRU TRANSACTION DRAWER/HEATER; EXACT PLACEMENT OF RECEPTACLES SHALL BE COORDINATED WITH BANK EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN. A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES:ELECTRICAL FLOORBOX SCHEDULE TYPE DESCRIPTION MFGR. FLOORBOX p/n COVERPLATE p/n POWER DEVICES DATA DEVICES NOTES FB2 2-GANG, MULTI-SERVICE CONCRETE FLOORBOX, W/RECTANGULAR COVER, 3" MIN. POUR HUBBELL-WIRING CFB2G30CR 24GCCVRXXX (1) DUPLEX RECPT. (3) RJ45 PROVIDE REQUIRED SUB-PLATES BANK EQUIPMENT ROUGH-IN: A. ELEC. CONTRACTOR SHALL CONDUCT A PRE-ROUGHIN MEETING WITH G.C. AND BANK EQUIPMENT INSTALLER PRIOR TO ANY ELECTIRCAL ROUGH-IN (ABOVE OR BELOW GRADE) BEING INSTALLED TO COORDINATE THE SPECIFIC ROUGH-IN REQUIREMENTS, LOCATIONS, ETC. OF ALL BANK EQUIPMENT; INCLUDING BUT NOT LIMITED TO: ATM'S, VACUUM TUBE SYSTEMS, CASH MACHINES, ETC. ALL CONDUIT STUB-UP LOCATIONS, DEVICE LOCATIONS, ETC. SHALL BE COORDINATED FOR THE DRIVE-THRU ISLANDS, BANK TELLER AREAS, ETC. M (2) 2"C. EA. W/ 3#3/0 + 1#3GND GROUNDING ELECTRODE SYSTEM SEE DETAIL THIS SHEET UNDERGROUND SECONDARY CONDUIT AND TENCHING BY E.C. CONDUCTORS PROVIDED AND INSTALLED BY ROCKY MOUNTAIN POWER CO. UNDERGROUND PRIMARY TRENCHING AND CONDUIT BY E.C. CONDUCTORS BY ROCKY MOUNTAIN POWER CO. UTILITY XFMR PROVIDED & INSTALLED BY RMP FIBERGLASS PAD BOX PROVIDED BY RMP AND INSTALLED BY E.C. SELF-CONTAINED METER BASE 320A 240V, 1P, 3W PER RMP CO. REQUIREMENTS PANEL 'A' *18,491A PAD BOX PROVIDED BY RMP AND INSTALLED BY E.C. (5/E3.1) FAULT CURRENT CALULATIONS WERE BASED ON INFINITE BUS, WITH AN ESTIMATED 75 KVA TRANSFORMER WITH A 1.69%Z. *18,491A BLDG. STEEL WATER MAIN GROUND BAR AT MAIN TTB GRND RODS MIN OF (2) 10FT APART STAND-OFF GROUND BAR LOCATED IN ELEC. RM NEXT TO SERVICE EQUIP. GROUND BAR SHALL BE ERICO #B543A010 OR EQUAL. PROVIDE AND INSTALL ALL REQ'D LUGS & TERMINALS. MOUNT VERT. TO CONSERVE AS MUCH WALL SPACE AS POSSIBLE. MAIN SERVICE EQUIPMENT G N NEUTRAL TO GND BOND AT THIS POINT ONLY #1/0 Cu #6 C u CONCRETE ENCASED ELECTRODE 3/ 4 " C . , 1 # 6 C u #1 / 0 C u #1 / 0 C u #4 C u WATER MAIN #1 / 0 C u 1 1 13053 STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP OFESSIONALENGIN EE R 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com Engineering Inc. Consulting Engineers PROJECT #: PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : SAM TEP 03/24/23 4/ 2 0 / 2 0 2 3 2 : 3 1 : 4 3 P M \ \ P A Y N E F I L E S E R V E R \ M a i n F i l e S t o ra g e \ 2 0 2 3 \ B e e h i v e F C U R e x b u r g - 2 3 2 2 \ 1 0 _ W o r k i n g D r a wi n g s \ B e e h i v e F C U R e x b u r g _ S A M _ P a y n e . r v t E3.0 19035 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . PO W E R R I S E R & S C H E D U L E S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 2322 SCALE: NONE1POWER RISER DIAGRAM SCALE: NONE2BLDG GROUNDING ELECTRODE SYSTEM DETAIL LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION MOUNTING VOLTS LAMPS MFGR.CATALOG # APPROVED MFGR'S NOTES EXTERIOR FE1 AREA POLE LIGHT, SINGLE-HEAD, TYPE 4 DIST. W/ HOUSESIDE SHIELD POLE (SEE DETAIL) MULTI-TAP LED-7754LM-4000K LITHONIA HEAD: RSX2 LED-P1-40K-R4-MVOLT-SPA-HS-DDBXD; POLE: SSS-25-4C-DM19AS-DDBXD COOPER FE2 LED FLOODLIGHT, FULL VISOR, MEDIUM SPOT (RIGHT ANGLE ARM MOUNT TO POLE) POLE LIGHT 120-277 LED-7370LM-4000K LITHONIA DSXF2 LED-P1-40K-MSP-MVOLT-IS-DMG-FV-DDBXD COOPER FE3 ARCHITECTURAL SCONCE LIGHT WALL 120-277 LED-1200LM-4000K COOPER 303-W2-LEDB2-4000-UNV-T2-DIM10-SCBA-EDGE LITHONIA 3 FE4 EXTERIOR LED WALL PACK WALL 120-277 LED-3200LM-4000K LITHONIA WDGE2LED-P3-40K-80CRI-VW-MVOLT-DDBXD COOPER 3 FE4E EXTERIOR LED WALL PACK, EMERG. BATTERY PACK WALL 120-277 LED-3200LM-4000K LITHONIA WDGE2LED-P3-40K-80CRI-VW-MVOLT-E10WH-DDBXD COOPER 3 FE5 6" ROUND RECESSED LED CAN, 0-10V DIMMING RECESSED 120-277 LED-2000LM-4000K COOPER LD6A20-DE010-ERM6A-20-840-6LM1H LITHONIA INTERIOR F1 4FT LED STRIP SURFACE 120-277 LED-4000LM-4000K COOPER 4SLSTP2040DD-120V LITHONIA F2 6" ROUND RECESSED LED CAN, 0-10V DIMMING RECESSED 120-277 LED-1000LM-4000K COOPER LD6A10-DE010-ERM6A-10-840-6LM1H LITHONIA F2E 6" ROUND RECESSED LED CAN, 0-10V DIMMING, W/ EM BATTERY PACK RECESSED 120-277 LED-1000LM-4000K COOPER LD6A10-DE010-EM14-ERM6A-10-840-6LM1H LITHONIA F3 2X2 LAY-IN GRID TROFFER RECESSED 120-277 LED-3500LM-4000K COOPER DRI-WS-4-L40-UNV-22-T1-HCD-W6 NO EQUALS F3E 2X2 LAY-IN GRID TROFFER, W/ EMERG. BATTERY PACK RECESSED 120-277 LED-3500LM-4000K COOPER DRI-WS-4-L40-UNV-22-T1-HCD-EL14W-W6 NO EQUALS F4 2X4 LAY-IN GRID TROFFER RECESSED 120-277 LED-4000LM-4000K COOPER DRI-WS-2-L40-UNV-24-T1-HCD-W6 NO EQUALS 1 F5 4FT LED LINEAR DIRECT/INDIRECT PENDANT, 0-10V DIMMING, WIRELESS CONTROL W/ INTEGRAL SENSOR SUSPENDED 120-277 LED-1500LM/FT 4000K COOPER DSI-WS-60L-840-1-120-STD-SWPD1-DC-SCBA-AC120-ST-4FT NO EQUALS 3,4,6 F6 8FT LED LINEAR DIRECT/INDIRECT PENDANT, 0-10V DIMMING SUSPENDED 120-277 LED-1500LM/FT 4000K COOPER DSI-WS-60L-840-1-120-STD-SWPD1-DC-SCBA-AC120-ST-8FT NO EQUALS 3,4,6 F7E 16FT LED LINEAR DIRECT/INDIRECT PENDANT, 0-10V DIMMING, WIRELESS CONTROL W/ INTEGRAL SENSOR, EMERG. BATTERY PACK SUSPENDED 120-277 LED-1500LM/FT 4000K COOPER DSI-WS-60L-840-1-120-STD-SWPD1-EL14W/EPC-DC-SCBA-AC120-ST-16FT NO EQUALS 3,4,6 F8 24FT LED LINEAR DIRECT/INDIRECT PENDANT, 0-10V DIMMING, WIRELESS CONTROL W/ INTEGRAL SENSOR SUSPENDED 120-277 LED-1500LM/FT 4000K COOPER DSI-WS-60L-840-1-120-STD-SWPD1-DC-SCBA-AC120-ST-24FT NO EQUALS 3,4,6 F8E 24FT LED LINEAR DIRECT/INDIRECT PENDANT, 0-10V DIMMING, WIRELESS CONTROL W/ INTEGRAL SENSOR, EMERG. BATTERY PACK SUSPENDED 120-277 LED-1500LM/FT 4000K COOPER DSI-WS-60L-840-1-120-STD-SWPD1-EL14W/EPC-DC-SCBA-AC120-ST-24FT NO EQUALS 3,4,6 F9 ARCHITECTURAL MONO-POINT PENDANT SUSPENDED 120 LED LAMP SONNEMAN SON130709 NO EQUALS F10 BATHROOM VANITY LIGHT WALL ABOVE MIRROR 120-277 (2) LED LAMP LIGHTOLOGY SVY665690 NO EQUALS LIFE SAFETY FX1 EDGE LITE EXIT SIGN W/90 MIN. BATTERY, GREEN LED, SINGLE FACE/DOUBL FACE WALL OR CEILING 120-277 WITH FIXTURE MULE LTG PVT-U-B-G-S/R-SCBA LITHONIA 3 FX2 WALL MOUNTED EXTERIOR EMERGENCY EGRESS LIGHT, W/HEATER WALL ABOVE DOOR 120-277 WITH FIXTURE COOPER AEL2-46-SCBA LITHONIA 3 1. REFER TO DRAWINGS FOR FIXTURES REQUIRED TO HAVE 0-10V OR STEP-LEVEL DIMMING CONTROL. PROVIDE FIXTURE(S) WITH LED DRIVER(S) AND REQUIRED DIMMING/SWITCH-LEG CONDUCTORS BETWEEN SWITCH(ES) AND FIXTURE(S) TO PROVIDE CONTROL AS INDICATED ON DRAWINGS. 2. FIXTURE TO BE CONTINUOUS ROW MOUNTED, LENGTH AS INDICATED ON DRAWINGS. PROVIDE REQUIRED ACCESSORIES/CONNECTORS FOR CONTINUOUS ROW MOUNTING. 3. SCBA - STANDARD COLOR BY ARCHITECT/OWNER (COORDINATE COLOR WITH ARCHITECT/OWNER PRIOR TO ORDERING.) 4. FIELD ADJUST PENDANT LENGTH AS REQUIRED, VERIFY LENGTH WITH COUNTER AS DIRECTED BY ARCHITECT. 5. REFER TO ARCHITECTURAL ELEVATION DRAWINGS FOR PLACEMENT AND MOUNTING HEIGHT OF FIXTURES. 6. REFER TO THE GENERAL LIGHTING CONTROL NOTES FOR COMMISSIONING OF WIRELESS CONTROLLED FIXTURES. LIGHT FIXTURE SCHEDULE NOTES: 1. PROVIDE ADDITIONAL POWER PACKS; SENSOR SWITCH PP20 AS NEED FOR QTY OF OCCUPANCY SENSORS/SWITCHES. 2. DEVICE COLOR SHALL MATCH WIRING DEVICES; REFER TO SPECIFICATIONS. 3. REFER TO MANUFACTURER DOCUMENTATION FOR QTY AND SIZE OF CONDUCTORS BETWEEN LOW VOLTAGE SWITCH, SENSOR(S) AND POWER/RELAY PACKS. 4. PROVIDE SECONDARY RELAY PACK; SENSOR SWITCH SP20 AS NEEDED TO PROVIDE DUAL-LEVEL SWITCHING OF FIXTURES. 5. PROVIDE 0-10V DIMMING CONDUCTORS (GREY & VIOLET) BETWEEN SWITCH AND LIGHT FIXTURES FOR DIMMING CONTROL. 6. CUSTOM WALLSTATION ENGRAVINGS IS REQUIRED FOR WALLSTATION AND SHALL BE SPECIFIED/COORDINATED WITH OWNER AFTER PROGRAMMING OF SYSTEM. OCC. SENSOR/LTG CONTROLS SCHEDULE NOTES: • E.C. SHALL BE REPSONSIBLE FOR THE PROGRAMMING/COMMISSIONING OF THE LIGHTING CONTROL SYSTEMS (WIRED AND WIRELESS SYSTEMS) TO FUNCTION AS INDICATED OR AS DIRECTED BY OWNER AND SHALL INCLUDE ALL REQUIRED COST IN THE BASE BID. THE DAYLIGHTING SET-POINTS SHALL BE COORDINATED WITH THE OWNER FOR EACH AREA PRIOR TO FINAL PROGRAMMING OF THE DAYLIGHTING SENSOR(S). ALL PROGRAMMING/COMMISSIONING SHALL BE DONE BY A FACTORY CERTIFIED OR TRAINED PERSON. • LIGHTING IN SPACES WITH WIRELESS CONTROLS SHALL BE FIELD TUNED TO FOOTCANDLE LEVELS THAT ARE SATISFACTORY TO THE OWNER DURING PROGRAMMING AND COMMISSIONING OF THE LIGHTING SYSTEMS. GENERAL LIGHTING CONTROL NOTES: LIGHTING OCCUPANCY SENSOR AND CONTROL SCHEDULE TYPE MFGR. CATALOG #DESCRIPTION NOTES APPROVED EQUALS CEILING SENSORS CD2 SENSOR SWITCH CM PDT 9 R DUAL-TECHNOLOGY, SMALL MOTION 360 DEGREE COVERAGE, LOW VOLTAGE, W/ISOLATED RELAY 1 COOPER CD6 SENSOR SWITCH CMR PDT 9 DUAL-TECHNOLOGY, LINE VOLTAGE, SMALL MOTION 800W MAX LOAD COOPER WALL SENSORS WD1 SENSOR SWITCH WSX PDT-**- DUAL-TECHNOLOGY, 1-POLE, NEUTRAL REQUIRED 2 COOPER WDD SENSOR SWITCH WSX-PDT-D DUAL-TECHNOLOGY, 0-10V DIMMING 2,5 COOPER WALL SWITCHPODS SPD SENSOR SWITCH sPODM-**-D LOW VOLTAGE PUSH-BUTTON SWITCHPOD, 1-POLE W/DIMMING 2,3,4,5 COOPER WIRELESS CONTROLS W1R COOPER W1L-RL-G WAVELINX 1-BUTTON LARGE WALL STATION W/ RAISE/LOWER 2 LITHONIA WAC COOPER WAC- POE & WPOE-120 WAVELINX WIRELESS AREA CONTROLLER, PROVIDE 120V PoE INJECTOR S = SHUNT-TRIP BREAKER G = GFCI BREAKER R = RED HANDLED, LOCK-OUT TYPE A = ARC-FAULT BREAKER GP = GFEPD BREAKER LCP = CRKT TO BE ROUTED THROUGH LTG CONTROL PANEL BRK NOTES: Elec. Heating 4500 VA 100.00% 4500 VA Power 9482 VA 100.00% 9482 VA Receptacle 19100 VA 76.18% 14550 VA TOTAL EST. DEMAND AMPS:262 A Other 2000 VA 100.00% 2000 VA TOTAL CONN. AMPS.:279 A Motor 9453 VA 105.13% 9938 VA TOTAL EST. DEMAND:62976 VA Lighting 2712 VA 100.00% 2712 VA TOTAL CONN. LOAD:67034 VA HVAC 20280 VA 100.00% 20280 VA LOAD CLASSIFICATION CONNECTED... DEMAND FACTOR EST. DEMAND PANEL TOTALS PANEL SUMMARY TOTAL AMPS:274 A 285 A TOTAL LOAD:32.9 kVA 34.1 kVA 71 ---- -- -- 4152 0 -- -- -- --72 69 CU - 2 40 A 2 4152 0 2 20 A -- SURGE PROTECTION DEVICE 70 67 ---- -- -- 3468 2520 -- -- -- --68 65 CU - 1 40 A 2 3468 2520 2 30 A FC-1a/1b 66 63 F - 2 30 A 1 1920 0 1 20 A -- SPARE 64 61 F - 1 30 A 1 1920 0 1 20 A -- SPARE 62 59 ---- -- -- 2250 0 1 20 A -- SPARE 60 57 WATER HEATER 30 A 2 2250 0 1 20 A -- SPARE 58 55 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 56 53 Drive-Thru Blwr 20 A 1 1392 0 1 20 A -- SPARE 54 51 Drive-Thru Blwr 20 A 1 1392 0 1 20 A -- SPARE 52 49 Drive-Thru Blwr (FUTURE) 20 A 1 1392 0 1 20 A -- SPARE 50 47 Drive-Thru Blwr (FUTURE) 20 A 1 1392 1000 -- -- -- --48 45 Receptacle - Cash Recycler 20 A 1 180 1000 2 20 A ELECTRIC WALL HEATER 46 43 Receptacle 20 A 1 360 540 1 20 A Receptacle 44 41 Receptacle 20 A 1 1025 1080 1 20 A Receptacle 42 39 Coin Machine 20 A 1 540 900 1 20 A Receptacle 40 37 ADA Doors 20 A 1 1000 900 1 20 A Receptacle 38 35 Receptacle 20 A 1 900 900 1 20 A Receptacle 36 33 Receptacle 20 A 1 478 1200 1 30 A Drive-Thru ATM 34 31 Receptacle-Drive-thru Window 20 A 1 900 2000 1 20 A Open/Closed Signage 32 29 Receptacle -Drive-thru Window 20 A 1 1080 500 1 20 A Night Deposit Box 30 27 Receptacle -Drive-thru Window 20 A 1 900 540 1 20 A Receptacle 28 25 Receptacle - Copy Mach. 20 A 1 540 720 1 20 A Receptacle 26 23 Receptacle - Trans. Drawer 20 A 1 180 1220 1 20 A Receptacle 24 21 Lighting 20 A 1 271 1140 1 20 A Receptacle 22 19 Lighting 20 A 1 801 360 1 20 A TTB 20 17 Lighting 20 A 1 1043 360 1 20 A TTB 18 15 HEAT TRACE GP/LCP 20 A 1 500 1080 1 20 A Receptacle 16 13 HEAT TRACE GP/LCP 20 A 1 1000 900 1 20 A Receptacle 14 11 HEAT TRACE GP/LCP 20 A 1 1000 720 1 20 A Receptacle - Soffit 12 9 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 10 7 Bldg - Signage LCP 20 A 1 1000 0 1 20 A -- SPARE 8 5 Bldg - Signage LCP 20 A 1 500 0 1 20 A -- SPARE 6 3 Lighting - Bldg Exterior LCP 20 A 1 523 500 1 20 A Signage 4 1 Lighting - Site LCP 20 A 1 352 900 1 20 A Receptale - Site 2 CKT CIRCUIT DESCRIPTION NOTE AMPS P A B P AMPS NOTE CIRCUIT DESCRIPTION CKT PROVIDE PANEL WITH INTEGRAL OR EXTERNAL SURGE PROTECTION DEVICE NOTES: MFGR/MODEL:SQ. D/NQ SERIES DIMENSIONS:20"W x 5.8"D x *"H FEED:BOTTOM ENCLOSURE:NEMA 1 BUSSING:SEE SPEC'S MBR AMPS:400 A MOUNTING:SURFACE WIRES:3 PANEL AMPS:400 A FED FROM: PHASES:1 PANEL TYPE:MBR BEEHIVE FCU - NORTH REXBURG PANEL LOCATION: VOLTAGE:120/240 Single A.I.C. RATING:22k PROJECT NAME: PANEL: A PAYNE ENGINEERING 1 City Comments 04/20/23 6" 3/4" C., 1#6 B.C. GRND. CONNECT TO BLDG. GROUND SYSTEM FINISH FLOOR TYPICAL CONDUITS OUT TO VOICE/ DATA OUTLETS. SEE PLAN FOR SIZE, ETC. (TYPICAL TOP & OR BOTTOM OF BOARD) 4'X8'X3/4" PLYWOOD PRIME & PAINT W/TWO COATS GREY ENAMEL (INSTALL ON WALLS AS INDICATED ON PLANS) ANCHOR SECURELY TO WALL W/ CONST. ADHESIVE. DOUBLE-DUPLEX OUTLET(S) PER PLANS 120V CIRCUIT PER PLANS PULL CORD UNISTRUT ANCHOR INCOMING UTILITY SERVICE CONDUIT(S) WITH INSULATED BUSHING. SEE SITE PLAN FOR SIZE, QUANTITY, ETC. GROUND BAR (SQ. D #PK27GTA) TELEPHONE, DATA, TV EQUIPMENT (TYP) INSTALL INSULATED BUSHING ON ALL CONDUIT ENDS. (TYP) UNISTRUT ANCHOR TEE BAR GRID POWER SUPPLY CONDUIT FOR CEILING OR WALL "J" BOX. SUPPORT WIRE BY ELECTRICAL CONTRACTOR INDEPENDENT OF CEILING SYSTEM. (TYPICAL) ACOUSTIC CEILING TILE SUPPORT CLIPS ALL SIDES ENTRANCE CONDUIT(S) 4" SQUARE BOX RAISED RING TO SUIT WALL RECEPTACLE - 20AMP RATED - SEE SPECIFICATIONS. NORMAL POWER COLOR - (SEE SPEC'S) COVER PLATE - STYLE & COLOR TO BE AS PER SPECIFICATIONS. CIRCUIT NUMBER TO BE WRITTEN ON BACK OF COVER W/FELT-TIP MARKER GREEN INSULATED GROUND CONDUCTOR PLAN VIEW ELEVATION VIEW PE R N E C 3 8 4 - 4 . WA L L PER NEC 110-26. 36" 30" WA L L 6' - 6 " A . F . F . 66 " 36" OR C E I L I N G 6' A . F . F . FINISH FLOOR PANEL OR ELECTIRCAL EQUIPMENT 13053 STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP OFESSIONALENGIN EE R 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com Engineering Inc. Consulting Engineers PROJECT #: PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : SAM TEP 03/24/23 3/ 2 3 / 2 0 2 3 1 1 : 3 0 : 2 2 A M \ \ P A Y N E F I L E S E R V E R \ M a i n F i l e S t or a g e \ 2 0 2 3 \ B e e h i v e F C U R e x b u r g - 2 3 2 2 \ 1 0 _ W o r k i n g D r aw i n g s \ B e e h i v e F C U R e x b u r g _ S A M _ P a y n e . r v t E3.1 19035 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . EL E C T R I C A L S C H E D U L E S & D E T A I L S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 2322 SCALE: NONE1TELEPHONE TERMINAL BOARD (TTB) DETAIL SCALE: NONE3RECESSED LIGHT FIXTURE DETAIL SCALE: NONE4RECEPTACLE MOUNTING DETAIL SCALE: NONE2ELECTRICAL EQUIP. CLEARANCE DETAIL MECHANICAL - EXHAUST FAN SCHEDULE ID # VOLTS PH. WATTS PANEL CIRCUIT FEEDER CONTROL NOTES EF 1 120 V 1 127 W A 19 3/4" C., 2#12+1#12GND W/LIGHTS 1 EF 2 120 V 1 127 W A 19 3/4" C., 2#12+1#12GND W/LIGHTS 1 EF 3 120 V 1 127 W A 33 3/4" C., 2#12+1#12GND TIMER SWITCH EF 4 120 V 1 87 W A 41 3/4" C., 2#12+1#12GND TIMER SWITCH 1. CIRCUIT AND CONTROL FAN WITH LIGHTING IN ROOM. 2. E.C. SHALL PROVIDE LOCAL DISCONNECT SWITCH FOR EQUIPMENT; SIZE AND TYPE AS INDICATED IN SCHEDULE. IF FUSED DISCONNECT IS SPECIFIED FOR EQUIPMENT, FUSE PER EQUIPMENT NAMEPLATE RATING. 3. E.C. SHALL PROVIDE LOCAL DISCONNECT RATED, THERMAL-OVERLOAD SWITCH FOR EQUIPMENT; SWITCH RATING SHALL NOT BE LESS THEN CIRCUIT BREAKER SUPPLYING EQUIPMENT. 4. EQUIPMENT IS FACTORY SUPPLYED WITH DISCONNECT AND CONVIENENCE OUTLET; E.C. SHALL PROVIDE ALL NECESSARY CONNECTIONS. 5. INDOOR UNIT IS POWERED FROM OUTDOOR UNIT; COORDINATE EXACT NUMBER OF CONDUCTORS BETWEEN UNITS WITH M.C. PRIOR TO ROUGH-IN. 6. PROVIDE 1/2" CONDUIT AND CONDUCTORS BETWEEN FURNACE AND CORRESPONDING OUTDOOR CONDENSING UNIT. COORDINATE SIZE AND NUMBER OF CONDUCTORS WITH M.C. PRIOR TO ROUGH-IN. PROVIDE CONNECTION BETWEEN FURNACE AND ASSOCIATED OUTSIDE AIR MOTORIZED DAMPER, COORDINATE WITH M.C. MECHANICAL SCHEDULE NOTES: MECHANICAL -ELECTRIC HEATER SCHEDULE ID # VOLTS PH. WATTS PANEL CIRCUIT FEEDER NOTES EH 1 240 V 1 2 kW A 46,48 3/4" C., 2#12+1#12GND MECHANICAL - CONDENSING UNIT SCHEDULE ID # VOLTS PH. MCA PANEL CIRCUIT FEEDER DISCONNECT SIZE DISCONNECT TYPE NOTES CU 1 240 V 1 29 A A 65,67 3/4' C., 2#8 + 1#10 GND 60 A FUSED/3R 2,6 CU 2 240 V 1 35 A A 69,71 3/4' C., 2#8 + 1#10 GND 60 A FUSED/3R 2,6 MECHANICAL - FURNACE SCHEDULE ID # VOLTS PH. HP PANEL CIRCUIT FEEDER NOTES F 1 120 V 1 1 A 61 3/4"C.,2#10+1#10G 3,6 F 2 120 V 1 1 A 63 3/4"C.,2#10+1#10G 3,6 MECHANICAL - SPLIT A/C UNIT SCHEDULE EQUIP. ID VOLTS PH. MCA CIRCUIT FEEDER DISCONNECT NOTES INDOOR UNIT FC-1a 240 V 1 1 A A-66,68 PER MFGR 0 A/N/A 5 OUTDOOR UNIT FC-1b 240 V 1 20 A A-66,68 3/4" C., 2#10+1#10GND 30 A/FUSED/3R 2,5 SCALE: NONE5RMP PAD BOX DETAIL