Loading...
HomeMy WebLinkAboutAPPROVED DRAWINGS RESPONSE - 23-00173 - Beehive Federal Credit UnionAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : Beehive Federal Credit Union Address : 220 E Moody Rd Record Type : New Commercial Building Document Filename : DRAWINGS - Beehive FCU North Rexburg Bid Set-Reviewed-Corrections-NBW Response.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 23-00173 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments G1.0 Stamp Cody Jones : Building Open 3 Approved - Building Inspector G1.0 Stamp Alex Owens : Electrical Open 3 Approved - Electrical Inspector E0.0 Free Text Alex Owens : Electrical Open 68 All electrical work to comply with 2017 NEC E0.0 Stamp Alex Owens : Electrical Open 68 Approved - Electrical Inspector SP1.1 Stamp Kyle Baldwin : P&Z Open 22 Approved - Planning and Zoning New Commercial Building Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) N NORTH ARROW ROOM . ROOM NAME ROOM NAME TAG ROOM NUMBER . . SECTION NUMBER BUILDING SECTION TAG PAGE NUMBER SYMBOLS LEGEND BREAK LINE SCALE: . ?" = 1'-0" DETAIL . DETAIL NUMBER DETAIL TITLE TAG PAGE NUMBER SCALE: . ?" = 1'-0" ELEVATION . INT. ELEV. TITLE TAG SCALE: ?" = 1'-0" TITLEMAIN TITLE TAG SCALE: . ?" = 1'-0" SECTION . DETAIL NUMBER PAGE NUMBER DETAIL NUMBER SECTION TITLE TAG PAGE NUMBER FINISHED FLOOR ELEV. 100'-0"ELEVATION TAG 1 REVISION TAG WALL TYPE TAG D-DOOR TYPE TAG W-WINDOW TYPE TAG ?KEYNOTE TAG R-ROOF TYPE TAG ROOM FINISHES TAG SCALE: . ?" = 1'-0" ELEVATION . EXT. ELEV. TITLE TAG DETAIL NUMBER PAGE NUMBER A101 1 DETAIL NUMBER DETAIL TAG PAGE NUMBER N E F S WB N1 E1 S1 W1 B1 F1 ADDITIONAL FINISH NOTES PLAN SOUTH WALL FINISH BASE FINISH PLAN WEST WALL FINISH PLAN NORTH WALL FINISH FLOOR FINISH ADDITIONAL FINISH NOTES PLAN EAST WALL FINISH 300 STOREFRONT TYPE TAG 9.6A-1 WALL'S FIRE RATING - HR UNIQUE WALL TYPE CONFIGURATION STRUCTURAL MATERIAL TYPE - CSI DIVISIONS STRUCTURAL MATERIAL WIDTH VICINITY MAP: REXBURG, IDAHO PROJECT LOCATION HWY 20 HWY 33 2N D E A S T MOODY ROAD DESIGN TEAM OWNER ARCHITECT CIVIL ENGINEERS LANDSCAPE ARCHITECT STRUCTURAL ENGINEERS MECHANICAL ENGINEERS ELECTRICAL ENGINEERS BEEHIVE FEDERAL CREDIT UNION CRAIG GUMMOW - CEO 1087 ERIKSON DRIVE REXBURG, IDAHO 83440 PHONE: (208) 656-1000 NBW ARCHITECTS P.A. 990 JOHN ADAMS PARKWAY IDAHO FALLS, IDAHO 83401 PHONE: (208) 522-8779 FAX: (208) 522-8785 CONNECT ENGINEERING 2295 N YELLOWSTONE HWY, STE #6 IDAHO FALLS, IDAHO 83401 PHONE: (208) 881-0081 BRECKON LAND DESIGN 6661 N. GLENWOOD ST GARDEN CITY, IDAHO 83714 PHONE: (208) 376-5153 FROST STRUCTURAL ENGINEERING 1020 E. LINCOLN RD. IDAHO FALLS, IDAHO 83401 PHONE: (208) 227-8404 ENGINEERED SYSTEMS ASSOCIATES 1355 EAST CENTER ST. POCATELLO, IDAHO 83201 PHONE: (208) 233-0501 FAX: (208) 233-0529 PAYNE ENGINEERING, INC. 1823 EAST CENTER ST. POCATELLO, IDAHO 83201 PHONE: (208) 232-4439 FAX: (208) 232-1435 ABBREVIATIONS # - NUMBER OR POUND & - AND A.F.F. - ABOVE FINISH FLOOR AL - ALUMINUM ALUM. - ALUMINUM B.O. - BOTTOM OF CMU - CONCRETE MASONRY UNIT CONC. - CONCRETE CONT. - CONTINUOUS DEMO. - DEMOLITION OR DEMOLISH DIA. - DIAMETER DN - DOWN EA. - EACH EIFS - EXTERIOR INSULATION & FINISHING SYSTEM ELEC. - ELECTRICAL ELEV. - ELEVATION EQ. - EQUAL EQUIP. - EQUIPMENT EXT. - EXTERIOR F.F. - FINISH FLOOR FRP - FIBERGLASS REINFORCED PLASTIC GA. - GAUGE GYP. - GYPSUM H.M. - HOLLOW METAL HR - HOUR HVAC - HEATING, VENTILATING, & AIR CONDITION I.D. - INSIDE DIAMETER I.M.P. - INSULATED METAL PANEL INSUL. - INSULATION INT. - INTERIOR MAX. - MAXIMUM MECH. - MECHANICAL MFR - MANUFACTURER MIN. - MINIMUM N.I.C. - NOT IN CONTRACT NO. - NUMBER O.C. - ON CENTER O.D. - OUTSIDE DIAMETER PLY - PLYWOOD PLUM. - PLUMBING PVC - POLYVINYL CHLORIDE RCP - REFLECTED CEILING PLAN REQ'D - REQUIRED SIM. - SIMILAR SPM - SINGLE PLY MEMBRANE STOR. - STORAGE STRUCT. - STRUCTURAL T.O. - TOP OF TYP. - TYPICAL U.N.O. - UNLESS NOTED OTHERWISE W/ - WITH W.C. - WATER CLOSET WD - WOOD I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 9 : 1 5 : 3 4 A M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t G1.0 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . GE N E R A L I N F O R M A T I O N APRIL 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 NEW BUILDING FOR: BEEHIVE FCU - NORTH REXBURG CORNER OF 2ND EAST AND MOODY RD. REXBURG, IDAHO 83440 CJR GLN DRAWING INDEX GENERAL G1.0 GENERAL INFORMATION G1.1 CODE ANALYSIS G1.2 ANSI STANDARDS CIVIL C1.00 COVER C2.00 NOTES C3.00 REFERENCE SHEET C4.00 EXISTING CONDITIONS C5.00 GENERAL LAYOUT C6.00 UTILITY LAYOUT C7.00 GRADING C8.00 DETAILS C9.00 DETAILS 2 C10.0 STORMTECH DETAILS C11.0 EROSION CONTROL LANDSCAPE L1.1 LANDSCAPE PLAN L1.5 LANDSCAPE DETAILS L2.1 IRRIGATION PLAN L2.5 IRRIGATION DETAILS L2.6 IRRIGATION DETAILS SITE DESIGN SP1.1 SITE PLAN - HORIZONTAL CONTROL SP2.1 SITE DETAILS SP2.2 SITE DETAILS SP2.3 SITE DETAILS ARCHITECTURAL A1.0 WALL AND ROOF TYPES A1.1 DIMENSION PLAN A1.2 ANNOTATION PLAN A1.3 REFLECTED CEILING PLAN A1.4 SIGNAGE, FLOOR FINISHED, AND DETAILS A1.5 OWNER FURNISHED PLAN A2.1 BUILDING ELEVATIONS A3.1 BUILDING SECTIONS A3.2 BUILDING SECTIONS A3.3 3D SECTIONS A4.1 WALL SECTION A4.2 WALL SECTIONS A4.3 WALL SECTIONS A4.4 ENLARGED SECTIONS AND ELEVATION A5.1 ENLARGED PLANS AND ELEVATIONS A5.2 ENLARGED PLANS, ELEVATIONS, AND SECTIONS A5.3 CASEWORK DETAILS A5.4 FLOOR PLAN DETAILS A6.1 DOOR SCHEDULE & ELEVATIONS A6.2 DOOR AND WINDOW DETAILS A7.1 ROOF PLAN A7.2 ROOF DETAILS PROJECT PERSPECTIVE DRAWING INDEX STRUCTURAL S1.0 GENERAL STRUCTURAL NOTES S1.1 SPECIAL INSPECTIONS S1.2 TYPICAL DETAILS S1.3 TYPICAL DETAILS S2.0 FOUNDATION PLAN S2.1 LOWER ROOF FRAMING PLAN S2.2 UPPER ROOF FRAMING PLAN S3.0 FOUNDATION DETAILS S3.1 FOUNDATION DETAILS S4.0 ROOF FRAMING DETAILS S4.1 ROOF FRAMING DETAILS S4.2 ROOF FRAMING DETAILS S4.3 ROOF FRAMING DETAILS MECHANICAL M1.0 MECHANICAL FOUNDATION PLAN M1.1 MECHANICAL FLOOR PLAN M2.1 MECHANICAL DETAILS M3.1 EQUIPMENT SCHEDULE AND DETAILS PLUMBING P1.0 PLUMBING FOUNDATION PLAN P1.1 PIPING FLOOR PLAN P2.1 PLUMBING DETAILS AND DIAGRAMS ELECTRICAL E0.0 ELECTRICAL SYMBOLS AND DETAILS E0.1 ELECTRICAL SITE PLAN E1.0 LIGHTING PLAN E2.0 POWER/DATA PLAN E3.0 POWER RISER AND SCHEDULE E3.1 ELECTRICAL SCHEDULES AND DETAILS 20 ' - 0 " 25 ' - 0 " 20 ' - 0 " 46'-6"66'-6"25'-0"20'-0" (TYP.) 9'-5" 8' - 7 " 26'-0"26'-0" 67 ' - 5 " 20 ' - 0 " 86'-6" 158'-0" 10 ' - 0 " 10 ' - 1 0 " 10'-0" 10'-7" 6' - 0 " 5' - 0 " 8' - 1 0 " 10'-0" 35 ' - 6 " 36 ' - 0 " 5' - 0 " 22 ' - 0 " 65 ' - 7 1 / 2 " 12 ' - 4 " 10 ' - 0 " (T Y P . ) R 7 . 5 ' R7.5 ' 6' - 0 " 6'-0" 6' - 6 " 15'-6" 9'-0"2'-0"9'-0"2'-0"9'-0"3'-6"10'-0" 32 ' - 2 " 1' - 1 1 " 1' - 1 1 " 4'-0" (TYP.) 19'-6" 15 ' - 8 " 12'-10"8'-1 1/2" 5'-0" 6'-6"11'-0" (VAN) 5'-0" 13'-9" 24 " 30 " 30 " 10'-0"4'-0"10'-0" 10'-0" R 1 0 . 0 ' SI T E P L A N - H O R I Z O N T A L C O N T R O L DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : GLN 22021 APRIL 2023 CJR 04 - 0 6 - 2 0 2 3 NSCALE: SITE PLAN 1" = 10'-0"SP1.1 1 City Plan Review 4/21/23 J FURN. FURN. CR CR CR J J CR J CR J J 6 4 3 1 2 ABDE 5 C AABBCC 1D-3 IP CAM 1 1D-3 IP CAM 1 1D-3 IP CAM 1 2 6D-5 1D-3 IP CAM 1 1D-3 IP CAM 1 1D-3 IP CAM 1 MANAGER 103 BREAK 107 OFFICE 1 104 MECH. 111 JAN./STOR. 112 DRIVE-THRU 106OFFICE 2 113 MAIN LOBBY 102 OFFICE 3 115 I.T. 116 TOILET 117 TOILET 118 VESTIBULE 101 1D-3 122" 1D-3 122" 1 1 IP CAMIP CAM 1D-3 IP CAM 1D-3 IP CAM 1 1 1D-3 122" IP CAM 1D-3 IP CAM 1 1D-3 IP CAM 1 1D-3 IP CAM 1 1D-3 IP CAM 1 1 2D-3 IP CAM 1 1D-3 IP CAM 2 2 3 3 2 3 2 3 2 3 2 1D-3 IP CAM 1 1D-3 IP CAM 1 1D-3 156"1 IP CAM 1 13053 STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP OFESSIONALENGIN EE R 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com Engineering Inc. Consulting Engineers PROJECT #: PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : SAM TEP 03/24/23 3/ 2 3 / 2 0 2 3 1 1 : 3 0 : 1 4 A M \ \ P A Y N E F I L E S E R V E R \ M a i n F i l e S t or a g e \ 2 0 2 3 \ B e e h i v e F C U R e x b u r g - 2 3 2 2 \ 1 0 _ W o r k i n g D r aw i n g s \ B e e h i v e F C U R e x b u r g _ S A M _ P a y n e . r v t E0.0 19035 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . EL E C T R I C A L S Y M B O L S & D E T A I L S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 2322 CIRCUITING & GENERAL SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION KEYED NOTE REFERENCE1 BRANCH CIRCUIT HOME-RUN TO PANEL INDICATED A-1,3,5 3/4"C.-6#12,1#12G QTY & SIZE OF EQUIPMENT GROUND CONDUCTOR QTY & SIZE OF NEUTRAL AND PHASE CONDUCTOR(S) SIZE OF CONDUIT A-1,3,5 3/4"C.-6#12,1#12G PANEL AND CIRCUIT DESIGNATIONS EQUIPMENT GROUNDING CONDUCTOR TICK MARKS NEUTRAL CONDUCTOR(S) PHASE AND/OR SWITCH-LEG CONDUCTOR(S) BRANCH CIRCUIT/FEEDER CONCEALED IN CEILING OR WALL BRANCH CIRCUIT/FEEDER CONCEALED UNDERGROUND OR FLOOR NEW EQUIPMENT, DEVICES, ETC. EXISTING EQUIPMENT, DEVICES, ETC. DEMOLITION EQUIPMENT, DEVICES, ETC. DETAIL # / SHEET REFERENCE1 / ES101 *25,000A CALCULATED AVAILABLE FAULT CURRENT AT EQUIPMENT(SEE POWER RISER) LIGHTING SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION PARKING AREA POLE LIGHT, SINGLE OR DOUBLE HEAD AS INDICATED ON DRAWINGS. REFER TO LIGHT POLE DETAIL FOR POLE INFORMATION. 2X4 FLUORESCENT OR LED FIXTURE 2X2 FLUORESCENT OR LED FIXTURE SURFACE MOUNTED FLUORESCENT OR LED FIXTURE STRIP FLUORESCENT OR LED FIXTURE WALL MOUNTED FLUORESCENT OR LED FIXTURE EXTERIOR WALL MOUNTED FIXTURE ROUND RECESSED FIXTURE SURFACE OR PENDANT FIXTURE LIGHT FIXTURE SUBSCRIPTS NL NIGHT-LIGHT(CONNECT TO UNSWITCHED LEG OF CIRCUIT) EXIT SIGN, WALL OR CEILING MOUNTING AS REQUIRED (SINGLE OR DOUBLE FACE) DIRECTIONAL CHEVRONS AS INDICATED; CONNECT TO UNSWITCHED LEG OF LIGHTING CIRCUIT THAT IS IN THE SAME AREA AS THE EXIT SIGNS. SHADED FIXTURE INDICATES AN EMERGENCY FIXTURE. PROVIDE WITH EMERG. BATTERY PACK OR CONNECT TO EMERGENCY POWER SYSTEM (WHERE APPLICABLE). CONNECT BATTERY PACK TO UNSWITCHED LEG OF LIGHTING CIRCUIT THAT SERVES THE SAME AREA AS THE EMERGENCY FIXTURE. PROVIDE WITH TEST LIGHT AND SWITCH. CEILING MOUNTED OCCUPANCY SENSOR, REFER TO OCCUPANCY SENSOR/SWITCH SCHEDULE FOR SENSOR TYPE AND ADDITIONAL INFORMATION. SWITCH MOUNTED OCCUPANCY SENSOR OR LOW VOLTAGE SWITCHPOD, REFER TO OCCUPANCY SENSOR/SWITCH SCHEDULE FOR TYPE AND ADDITIONAL INFORMATION. SINGLE-POLE SWITCH DUAL-LEVEL SWITCH, PROVIDE CONTROL OF FIXTURES TO ALLOW OCCUPANT TO REDUCE LIGHT LEVEL TO 50%. (SUBSCRIPT APPLIES TO BOTH SWITCHES) SWITCH SUBSCRIPTS 3 3-WAY SWITCH 4 4-WAY SWITCH D DIMMER SWITCH (COMPATIBLE W/ LOAD & LTG TYPES) K KEYED SWITCH F TIMER SWITCH (INTERMATIC MODEL EI400 SERIES) P PILOT LIGHTED SWITCH F1 LIGHT FIXTURE TYPE DESIGNATION S ### WALL OR CEILING MOUNTED EMERGENCY LIGHTING UNIT W/BATTERY PACK CONNECT TO UNSWITCHED LEG OF LIGHTING CIRCUIT THAT IS IN THE SAME AREA AS THE EMERGENCY LIGHT. LV LOW-VOLTAGE SWITCH (PER DWG'S) T THERMAL-OVERLOAD SWITCH M SWITCH SUPPLIED WITH EQUIPMENT, INSTALLED BY E.C. WP WEATHERPROOF 2P DOUBLE POLE, SINGLE THROW SWITCH GENERAL LIGHTING NOTES: A. SYMBOLS SHOWN ABOVE MAY NOT REPRESENT ALL LIGHT FIXTURES USED ON PROJECT, REFER TO LIGHT FIXTURE SCHEDULE FOR ACTUAL FIXTURE INFORMATION INCLUDING FIXTURE TYPE, LAMPING, MOUNTING AND ETC. B. JUNCTION BOXES FOR LIGHTING CIRCUITING ARE NOT SHOWN FOR CLARITY. THE E.C. IS RESPONSIBLE FOR PROVIDING AND INSTALLING ALL JUNCTION BOXES REQUIRED FOR CIRCUITING OF ALL LIGHT FIXTURES THAT ARE NOT LISTED FOR "THROUGH-BRANCH CIRCUIT WIRING". C. IN GENERAL ALL SWITCH-LEG CONDUCTORS MAY NOT BE SHOWN ON DRAWINGS; E.C. SHALL PROVIDE AND INSTALL CONDUCTORS AS REQUIRED TO ACHIEVE CONTROL SCHEMES INDICATED AND DESCRIBED ON DRAWINGS. INCLUDING ALL 0 - 10V DIMMING CONTROLS BETWEEN SWITCH AND FIXTURES. D. ALL BATTERY EXIT SIGNS AND EMERGENCY LIGHTING TO BE CONNECTED TO THE UNSWITCHED LEG OF THE LIGHTING CIRCUIT IN THE AREA. ### F M POWER SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION ELECTRICAL SWITCHBOARD EQUIPMENT, (SEE POWER RISER AND PANEL SCHEDULES FOR ADDITIONAL INFORMATION) 'MSB' 'T##'DRY-TYPE TRANSFORMER, (SEE POWER RISER FOR ADDITIONAL INFORMATION) 'LA' ELECTRICAL PANELBOARD, (SEE POWER RISER AND PANEL SCHEDULES FOR ADDITIONAL INFORMATION) DISCONNECT SWITCH, SIZE/POLES/TYPE AS INDICATED TYPES: 1=NEMA 1, 3R=NEMA 3R, 4X=NEMA 4X30A/3P/3R FUSED DISCONNECT SWITCH, SIZE/POLES/TYPE AS INDICATED TYPES: 1=NEMA 1, 3R=NEMA 3R, 4X=NEMA 4X30A/3P/3R (30A FUSES) COMBINATION STARTER & FUSED DISCONNECT SWITCH, SIZE/POLES/TYPE AS INDICATED. TYPES: 1=NEMA 1, 3R=NEMA 3R, 4X=NEMA 4X J JUNCTION BOX CR = CORD REEL; SEE DRAWINGS FOR INFORMATION CD = CORD DROP; SEE DRAWINGS FOR INFORMATION EQUIPMENT CONNECTION; COORDINATE CONNECTION WITH EQUIPMENT PRIOR TO ROUGH-IN MOTOR CONNECTION POWER AND/OR DATA SERVICE POLE FLOORBOX WITH POWER ONLY (SEE FLOORBOX SCHEDULE FOR ADDITIONAL INFORMATION) PUSHBUTTON STATION FLOORBOX WITH POWER AND DATA(SEE FLOORBOX SCHEDULE FOR ADDITIONAL INFORMATION) FB# FB# SPECIAL RECEPTACLE (COORDINATE NEMA TYPE WITH EQUIP.) (REFER TO PANEL SCHEDULES FOR AMPS) CEILING MOUNTED DUPLEX RECEPTACLE (COORDINATE PLACEMENT WITH CEILING EQUIPMENT PRIOR TO ROUGH-IN) DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT GFCI-TYPE DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT DOUBLE-DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT GFCI-TYPE DOUBLE-DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT. RECEPTACLE AND EQUIPMENT SUBSCRIPTS AC ABOVE COUNTER WP WEATHERPROOF (UL LISTED WEATHER-RESISTANT) 42"MOUNTING HEIGHT AFF OR AFG IG ISOLATED GROUND S SURGE-PROTECTION TYPE REF REFRIGERATOR W WASHING MACHINE D DRYER (30A-240V RATED RECPT.) M MICROWAVE HVAC THERMOSTAT OR SENSOR; PROVIDE & INSTALL BACKBOX,3/4" CONDUIT AND CONDUCTORS TO ASSOCIATED HVAC UNIT. COORDINATE EXACT LOCATION & SIZE AND NUMBER OF CONDUCTORS WITH M.C. T SOR 30A/3P/3R SIZE 1 (30A FUSES) SMALL EXHAUST FAN CONNECTION TV 120V RECEPT. FOR TV; VERIFY HEIGHT WITH ARCH. DRAWINGS & ELEVATIONS USB 120V RECPT. WITH USB CHARGING PORTS EWC ELECTRIC WATER COOLER; (SEE DETAIL. RECPT. SHALL BE ACCESSIBLE, DO NOT MOUNT BEHIND HOUSING.) DISP GARBAGE DISP. (UNDER SINK) DW DISHWASHER (COORDINATE W/ MILLWORK, INSTALL PER NEC 422.16(B)(2)). M/R MICROWAVE/RANGE HOOD (COORDINATE W/ MILLWORK) R ELECTRIC RANGE (50A-240V RATED RECPT.) GENERAL SPECIAL SYSTEM NOTES: A. ALL DEVICES SHOWN AT OR NEAR MILLWORK/CASEWORK SHALL BE COORDINATED WITH THE ARCHITECTURAL ELEVATION DRAWINGS AND MILLWORK INSTALLER TO INSURE PROPER MOUNTING HEIGHTS. CONTRACTOR SHALL ADJUST DEVICES AS NECESSARY IN ORDER TO POSITION DEVICES SUCH THAT THEY WILL NOT FALL BEHIND MILLWORK, CABINETS OR BE DIRECTLY ABOVE SINKS OR MIDWAY BETWEEN TILEWORK/WALL OR WAINSCOATING, ETC. B. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL A GFCI TYPE RECEPTACLE FOR ALL RECPTACLES SHOWN IN TOILET RMS, BATHROOMS, KITCHENS/SERVING AREAS, ROOFTOP, OUTDOORS OR WITHIN 6FT OF ANY SINK, BASIN, TUB OR FLOOR SINK AND ALL OTHER AREAS DEFINED BY THE NEC. SPECIAL SYSTEMS SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION DATA OUTLET; _= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW)_D-X TELEPHONE OUTLET; _= # OF TELEPHONE CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW) _T-X TELEPHONE/DATA OUTLET; _= # OF TELEPHONE/DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW) _T/_D-X CEILING MOUNTED DATA OUTLET; _= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW) _D-X A. COMMUNICATIONS CABLES SHALL HAVE BENDS NO GREATER THAN 90 DEG. B. CONDUITS FOR COMMUNICATIONS CABLING SHALL HAVE A MAXIMUM BEND RADIUS NOT MORE THAN 10X THE DIAMETER OF THE CONDUIT. C. ALL COMMUNICATIONS CONDUITS SHALL BE TERMINATED WITH AN INSULATED NON-METALLIC BUSHING AT BOTH ENDS. D. COMMUNICATIONS CONDUITS SHALL HAVE NO MORE THAN (2) 90'S WITHOUT A PULLBOX. PULL BOXES SHALL BE LOCATED IN ACCESSIBLE LOCATIONS AND SHALL BE SIZED AT LEASED 12X THE LARGEST CONDUIT DIAMETER IN LENGTH AND MIN, 4" DEEP AND 8" WIDE. E. IT SHALL BE THE RESPONSIBILITY OF THE E.C. TO INSURE THAT THE PATHWAY FOR THE DATA CABLING DOES NOT CREATE CABLE LENGTHS TO EXCEEDS THE LENGTH OF 295FT FROM OUTLET TO PATCH PANEL, THIS INCLUDES SERVICE LOOPS AND PATCH CORDS. F. WHERE CABLE TRAY IS UTILIZED IN THE PROJECT. COMMUNICATION CONDUITS ENDING AT THE CABLE TRAY SHALL EXTEND 1" OVER THE SIDE INTO THE TRAY. GENERAL SPECIAL SYSTEM NOTES: RECESSED WALL MOUNTED AV/TV ENCLOSURE, (SEE NOTE 2 BELOW) HUBBELL ENCLOSURE# NSAV62M W/ COVER# NSAV6C, (1) POWERKIT HBL#NSOKPS, (1) DATA PLATE W. TERMINATIONS. MOUNT 5'-0" AFF; FIELD COORDINATE WITH TV LOCATION. E.C. SHALL INSTALL 1 1/4"C FROM DATA COMPARTMENT TO NEAREST ACCESSIBLE CEILING SPACE. INSTALL DATA CABLING AND TERMINATIONS AS INDICATED ON DRAWINGS. LARGE CAPACITY 2-GANG AV BOX, (SEE NOTE 2 BELOW) HUBBELL# HBL260 WITH 2-GANG MUDRING; PROVIDE 2-GANG DECORA COVER PLATE W/ (1) DATA INSERT (LEVITON P/N: 4164*-*) (1) BRUSH PASSTHROUGH INSERT (LEVITON P/N: 41075-DB*). INSTALL 1 1/2" CONDUIT FROM BOX TO ABOVE ACCESSIBLE CEILING. INSTALL DATA CABLING AND TERMINATIONS AS INDICATED ON DRAWINGS. TV AV _D-X _D-X SPECIAL SYSTEMS NOTES: 1. UTILIZE 4 11/16" DEEP BOX WITH REQUIRED MUDRING AND CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING OR DATA RACK, TERMINATE WITH INSULATED THROAT BUSHING. PROVIDE QTY OF CABLES INDICATED FROM OUTLET TO NEAREST TELE/DATA ROOM. SEE DWGS FOR ADDITIONAL INFORMATION. UTILIZE J-HOOKS 3FT ON CENTER FOR SUPPORT OF CABLING WHERE CABLE TRAY IS NOT INSTALLED/SPECIFIED. 2. CONDUIT SIZE ('X' FROM ABOVE); 2=1/2", 3=3/4", 4=1", 5=1-1/4", 6=1-1/2" 3. BLANK (NO LABEL) = 4-11/16" DEEP BOX WITH REQUIRED MUDRING AND 1" CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING OR TO DATA RACK, TERMINATE WITH INSULATED THROAT BUSHING, PROVIDE PULL STRING. (UNLESS OTHERWISE NOTED) WALL PATHWAY SYSTEM; STI FIRESTOP EZ-PATH SERIES INSTALL THROUGH WALL ABOVE ACCESSIBLE CEILING, FIELD VERIFY EXACT LOCATION TO AVOID CONFLICT WITH OTHER TRADES AND UTILITIES. PROVIDE ALL REQUIRE MOUNTING HARDWARE AND ETC. FOR COMPLETE INSTALLATION. EPF2 = FIRE RATED, EZ-PATH SERIES 22 EPF3 = FIRE RATED, EZ-PATH SERIES 33 EPF4 = FIRE RATED, EZ-PATH SERIES 44 EP3 = NON-FIRE RATED, EZ-PATH 33NEZ SERIES ### FB# _D-X MULTI-SERVICE FLOORBOX; SEE FLOORBOX SCHEDULE FOR ADDITIONAL INFORMATION. _= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW) P 1PH 2/C 3/C 3P 3PH 3W 4W AC ADA AFF AFG AIC AL A or AMP ANN AP ATS AV AWG BFG C CATV CB CCTV CKT C CP CT CU DS EA E.C. EM EMT ENT EPO EQUIP EX FA FACP FLA FMC GND G.C. GEN GFI GFP HD HID HOA HP HPS HV HZ IG IMC J-BOX ABBREVIATIONS SINGLE POLE SINGLE-PHASE TWO-CONDUCTOR THREE-CONDUCTOR THREE POLE THREE-PHASE THREE-WIRE FOUR-WIRE ABOVE COUNTER AMERICANS WITH DISABILITIES ACT ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMPERE INTERRUPTING CAPACITY ALUMINUM AMPERE ANNUNCIATOR ACCESS POINT (WIRELESS DATA) AUTOMATIC TRANSFER SWITCH AUDIO VISUAL AMERICAN WIRE GAGE BELOW FINISHED GRADE CEILING MOUNTED CABLE TELEVISION CIRCUIT BREAKER CLOSED CIRCUIT TELEVISION CIRCUIT CONDUIT CONTROL PANEL CURRENT TRANSFORMER COPPER DISCONNECT SWITCH EACH ELECTRICAL CONTRACTOR EMERGENCY ELECTRICAL METALLIC TUBING ELECTRICAL NONMETALLIC TUBING EMERGENCY POWER OFF EQUIPMENT EXISTING FIRE ALARM FIRE ALARM CONTROL PANEL FULL LOAD AMPS FLEXIBLE METAL CONDUIT GROUND GENERAL CONTRACTOR GENERATOR GROUND FAULT CIRCUIT INTERRUPTER GROUND FAULT PROTECTION HEAVY DUTY HIGH INTENSITY DISCHARGE HAND-OFF-AUTOMATIC HORSE POWER HIGH PRESSURE SODIUM HIGH VOLTAGE HERTZ ISOLATED GROUND INTERMEDIATE METAL CONDUIT JUNCTION BOX V KVA kW kWh LED LFMC LFNC LTG LV MAX M.C. MCA MCB MCC MDP MH MIN MLO MOCP NA NC NEC NEMA NFPA NIC NL NO NTS OC OH DR OL PB P PNL PT PTZ QTY RCP RMC RNC SCA SCBA SF SPD SPEC SWBD SWGR TL TP TTB TV TYP UG UPS V VA V.I.F. VFD W/ W/O WP XFMR KILOVOLT KILOVOLT AMPERE KILOWATT KILOWATT HOUR LIGHT EMITTING DIODE LIQUID TIGHT FLEXIBLE METAL CONDUIT LIQUID TIGHT FLEXIBLE NONMETALLIC CONDUIT LIGHTING LOW VOLTAGE MAXIMUM MECH. CONTRACTOR MINIMUM CIRCUIT AMPS MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MAIN DISTRIBUTION PANEL MANHOLE MINIMUM MAIN LUGS ONLY MAXIMUM OVERCURRENT PROTECTION NOT APPLICABLE NORMALLY CLOSED NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NATIONAL FIRE PROTECTION ASSOCIATION NOT IN CONTRACT NIGHT LIGHT NORMALLY OPEN NOT TO SCALE ON CENTER OVERHEAD DOOR OVERLOAD PUSHBUTTON PHASE PANEL POTENTIAL TRANSFORMER PAN/TILT/ZOOM QUANTITY REFLECTED CEILING PLAN RIGID METAL CONDUIT RIGID NONMETALLIC CONDUIT SHORT CIRCUIT AMPS STANDARD COLOR BY ARCHITECT SQUARE FOOT (FEET) SURGE PROTECTION DEVICE SPECIFICATION SWITCHBOARD SWITCHGEAR TWIST LOCK TWISTED PAIR TELEPHONE TERMINAL BOARD TELEVISION TYPICAL UNDERGROUND UNINTERRUPTIBLE POWER SUPPLY VOLTS VOLT AMPERE VERIFY IN FIELD VARIABLE FREQUENCY DRIVE WITH WITHOUT WEATHERPROOF TRANSFORMER • ELECTRICAL CONTRACTOR SHALL REFER TO THE MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL MECHANICAL EQUIPMENT AND ELECTRICAL CONNECTIONS. • ELECTRICAL CONTRACTOR SHALL PROVIDE MINIMUM WORKING CLEARANCE AS PER NEC BEFORE INSTALLING ANY ELECTRICAL PANELS OR CABINETS. SEE ELECTRICAL EQUIPMENT CLEARANCE DETAIL. • INSTALL ALL LIGHT FIXTURES IN MECHANICAL ROOM AFTER THE MECHANICAL EQUIPMENT IS IN PLACE. ADJUST AS NECESSARY. PROVIDE CHAIN SUSPENSION KITS AS REQUIRED. • REFER TO ARCHITECTURAL REFLECTED CEILING PLAN(S) FOR EXACT FIXTURE LOCATIONS, CEILING TYPES, ETC. • ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONCRETE PADS AS REQUIRED FOR ALL ELECTRICAL EQUIPMENT. • CONFIRM EXACT LOCATIONS OF ALL TELEPHONE/DATA OUTLETS WITH OWNER PRIOR TO ROUGH-IN. • LOCATE SWITCHES, OUTLETS, ETC., SHOWN AT ROOM ENTRY DOORWAYS, AS CLOSE TO DOOR FRAME AS POSSIBLE, SO AS NOT RO INTERFERE WITH ROOM CABINETS, ETC. PROJECT GENERAL NOTES: • SUPPORT ALL LIGHT FIXTURES INDEPENDENT OF CEILING. • ELECTRICAL CONTRACTOR SHALL OBTAIN ALL APPLICABLE PERMITS FOR WORK AND PAY ASSOCIATED FEES. • MAINTAIN 24" MIN. CLEARANCE FROM ALL COMMUNICATIONS CABLING AND ELECTRONIC BALLASTS. • UNLESS SPECIFICALLY INDICATED OTHERWISE, ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ANY SPECIAL SYSTEMS SUPPLIER/CONTRACTOR; DENTAL, MEDICAL, KITCHEN, SPECIALIZED EQUIPMENT, ETC. FOR THE EXACT ROUGH-IN REQUIREMENTS FOR THEIR EQUIPMENT. ALSO UNLESS INDICATED OTHERWISE, THE ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR FINAL ELECTRICAL CONNECTIONS TO ALL SPECIAL EQUIPMENT. • ALL CONDUIT/RACEWAY/CABLES TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. IF ANY SURFACE WORK IS NECESSARY, IT SHALL BE APPROVED BY THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION. • ELECTRICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND THOROUGHLY INVESTIGATE THE EXISTING CONDITIONS, AS THEY RELATE TO THE SCOPE OF WORK DESCRIBED. MAKE NECESSARY PROVISIONS IN THE BASE BID TO ADEQUATELY ACCOMMODATE THESE CONDITIONS. TYPICAL DEVICE MOUNTING HEIGHTS: GENERAL COORDINATION NOTE: GENERAL DETAIL NOTES: FINISH FLOOR 1' - 6'' THERMOSTAT OR SENSORVERIFY WITH M.C. PRIOR TO LIGHT SW. (OR AS NOTED) * 4' - 0'' * 3' - 6'' (OR AS NOTED) RECEPTACLE @ MILLWORK BACKSPLASH CA B . D I M E N S I O N S PE R A R C H . D E T A I L 6" CABINET *E.C. SHALL COORDINATE ALL DEVICE MOUNTING HGTS. AND EXACT LOCATION WITH ARCHITECTURAL INTERIOR ELEVATIONS REPORT CONFLICTS TO ARCHITECT **PRIOR TO ROUGH-IN** ROUGH-IN. TYPICAL FOR ALL DEVICES MOUNTED ABOVE COUNTER (ie C.O.'S, DATA, PHONE etc.) A. B. C. D. ALL MOUNTING HEIGHTS TYPICAL UNLESS NOTED OTHERWISE. COORDINATE OUTLET HEIGHTS WITH ARCHITECTS MILLWORK DWGS. TO INSURE THAT OUTLETS WILL NOT FALL BEHIND CABINETS, BACKSPLASHES, OR INTERFERE WITH WAINSCOTING, ETC. ALL SWITCHES AND THERMOSTATS TO BE MOUNTED AS CLOSE TO DOOR JAMS AS POSSIBLE. COORDINATE ALL DEVICES WITH ARCHITECTURAL PLANS AND DETAILS. COORDINATE LIGHT SWITCH & OUTLET HEIGHTS WITH ARCHITECTURAL WAINSCOTING AND OR TILE WORK SO AS NOT TO FALL MIDWAY IN THESE FINISHES. FIRE 6' - 8'' FIRE ALARM NOTIFICATION DEVICE FIRE MANUAL PULL STATION HANDLE SHALL BE BETWEEN 42" & 48" AFF CABINET RECEPT. TELE/DATA OUTLET TV OUTLET SECURITY & ACCESS CONTROL SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION PROVIDE ROUGH-IN FOR CARD REAADER WITH A 3/4" CONDUIT & PULL CORD FROM WIRING CHASE IN DOOR FRAME TO ABOVE NEAREST ACCESSIBLE CEILING SPACE. E.C. SHALL COORDINATE WITH ACCESS CONTROL CONTRACTOR. CR PROVIDE AND INSTALL A 3/4" CONDUIT & PULL CORD FROM WIRING CHASE IN DOOR FRAME TO ABOVE NEAREST ACCESSIBLE CEILING SPACE. E.C. SHALL ARRANGE A PRE- INSTALLATION MEETING WITH G.C. AND DOOR HARDWARE SUPPLIER TO COORDINATE EXACT PALCEMENT PRIOR TO ROUGH-IN. • PRIOR TO ROUGH IN E.C. SHALL HAVE A COORDINATION MEETING WITH SECURITY CONTRACTOR FOR REQUIRED ROUGH-IN FOR ALL SECURITY/ACCESS CONTROL EQUIPMENT. GENERAL SECURITY & ACCESS CONTROL NOTES: IDAHO POWER CO. ROCKY MOUNTAIN POWER CO. WWW.IDAHOPOWER.COM WWW.ROCKYMOUNTAINPOWER.NET CONTACT: CONTACT: SHELLEY MARTIN (208) 388-5872 DAN KUHL (503) 308-0233 OR DAN KUHL (503) 308-0233 dan.kuhl@evergreen-efficiency.com dan.kuhl@evergreen-efficiency.com UTILITY LIGHTING REBATES & INCENTIVES: IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PREPARE ALL REQUIRED APPLICATIONS AND INFORMATION REQUIRED TO PROVIDE THE OWNER WITH THE MAXIMUM AMOUNT OF REBATE DOLLARS FROM THE LOCAL UTILITY COMPANY. THE ELECTRICAL CONTRACTOR SHALL SUBMIT VERIFICATION OF THE UTILITY COMPANY PRE-APPLICATION APPROVAL PRIOR TO ORDERING ANY MATERIALS. VISIT THE FOLLOWING UTILITY CO. WEBSITES FOR INFORMATION: SCALE: 1/8" = 1'-0"1 SECURITY/ACCESS CONTROL & SOUND SYSTEM ROUGH-IN PLAN 1 E.C. SHALL PROVIDE REQUIRED ROUGH-IN AND CABLING FOR IP CAMERAS; PRIOR TO ROUGH-IN E.C. SHALL COORDINATE EXACT LOCATIONS WITH OWNER; SEE GENERAL NOTES FOR OWNER CONTACT INFORMATION. ALL IP CAMERA CABLING SHALL TERMINATE IN DEDICATED PATCH PANEL(S) IN DATA RACK. 2 E.C. SHALL PROVIDE REQUIRED ROUGH-IN INCLUDING BOX AND CONDUIT TO SECURITY SYSTEM HEAD-END EQUIPMENT AS DIRECTED BY SECURITY CONTRACTOR. E.C. SHALL COORDINATE SECURITY ROUGH-IN REQUIREMENTS WITH SECURITY CONTRACTOR PRIOR TO WORK; SEE GENERAL NOTES. 3 PROVIDE AND INSTALL A 120V CIRCUIT IN J-BOX ABOVE ACCESSIBLE CEILING. LABEL "ACCESS CONTROL POWER SUPPLY" FOR USE BY ACCESS CONTROL CONTRACTOR. UTILIZE NEAREST 120V RECEPTACLE CIRCUIT IN AREA. SOUND SYSTEM SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION VOLUME CONTROLLER E.C SHALL PROVIDE ROUGH-IN; BOX, MUDRING AND 1/2" C. WITH PULL STRING TO ACCESSIBLE CEILING OR SPEAKER; COORDINATE WITH SOUND SYSTEM CONTRACTOR. ZACH McCLEERY W/ ACS 208-571-7007. KEY NOTES:# 16'8'0" All electrical work to comply with 2017 NEC