HomeMy WebLinkAboutAPPROVED DRAWINGS - 23-00173 - Beehive Federal Credit UnionAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Don Allen Don.Allen@rexburg.org 208-372-2174 Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : Beehive Federal Credit Union Address : 220 E Moody Rd Record Type : New Commercial Building Document Filename : DRAWINGS - Beehive FCU North Rexburg Bid Set.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 23-00173 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments G1.0 Free Text Cody Jones : Building Open 1 Exit signs and Exit lighting to comply with 1008 and 1013. G1.0 Stamp Cody Jones : Building Open 1 Corrections Required G1.1 Free Text Cody Jones : Building Open 2 To be van accessible. G1.1 Free Text Cody Jones : Building Open 2 Concealed spaces need to have fire blocking and draft stopping installed as per Section 718. G1.1 Free Text Cody Jones : Building Open 2 Not fewer then two drinking fountains shall be provided. One for people who use wheelchair and one for standing person. Section 1109.5.1. G1.1 Free Text Cody Jones : Building Open 2 Ventilation to provided and comply with Section 1203. L1.1 Free Text Cody Jones : Building Open 15 Grade to slope 6" in first 10'. SP1.1 Free Text Cody Jones : Building Open 20 Cross slope of sidewalks and landings at doors not to exceed 2%. A1.3 Free Text Cody Jones : Building Open 27 Suspended ceiling to be installed to manufactures specifications. New Commercial Building Approval of plans does not constitute approval of variance from code Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments S1.0 Free Text Cody Jones : Building Open 46 Stamped Engineered roof trusses approved by Building Design Professional needed when received. S1.1 Free Text Cody Jones : Building Open 47 Special Inspector needs to be identified as per Section1704.2.1 S2.0 Free Text Cody Jones : Building Open 50 Damp proofing and water proofing to comply with IBC Section 1804.4. S2.0 Free Text Cody Jones : Building Open 50 City Ordinance requires one horizontal bar in top 6" of wall. G1.0 Stamp Alex Owens : Electrical Open 1 Corrections Required G1.0 Free Text Alex Owens : Electrical Open 1 Requirements on pg 70 are above and beyond 2017 NEC. Please verify with engineer requirements on plan are what he wants installed. E3.0 Callout Alex Owens : Electrical Open 70 2017 NEC requires minimum #4 GEC. Please verify 1/0 is desired. E3.0 Callout Alex Owens : Electrical Open 70 2017 NEC requires minimum #6 GEC for ground rods. Please verify #4 is desired. G1.0 Stamp Don Allen : Mechanical Open 1 Approved - Plumbing Inspector G1.0 Stamp Don Allen : Mechanical Open 1 Approved - Mechanical Inspector Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) N NORTH ARROW ROOM . ROOM NAME ROOM NAME TAG ROOM NUMBER . . SECTION NUMBER BUILDING SECTION TAG PAGE NUMBER SYMBOLS LEGEND BREAK LINE SCALE: . ?" = 1'-0" DETAIL . DETAIL NUMBER DETAIL TITLE TAG PAGE NUMBER SCALE: . ?" = 1'-0" ELEVATION . INT. ELEV. TITLE TAG SCALE: ?" = 1'-0" TITLEMAIN TITLE TAG SCALE: . ?" = 1'-0" SECTION . DETAIL NUMBER PAGE NUMBER DETAIL NUMBER SECTION TITLE TAG PAGE NUMBER FINISHED FLOOR ELEV. 100'-0"ELEVATION TAG 1 REVISION TAG WALL TYPE TAG D-DOOR TYPE TAG W-WINDOW TYPE TAG ?KEYNOTE TAG R-ROOF TYPE TAG ROOM FINISHES TAG SCALE: . ?" = 1'-0" ELEVATION . EXT. ELEV. TITLE TAG DETAIL NUMBER PAGE NUMBER A101 1 DETAIL NUMBER DETAIL TAG PAGE NUMBER N E F S WB N1 E1 S1 W1 B1 F1 ADDITIONAL FINISH NOTES PLAN SOUTH WALL FINISH BASE FINISH PLAN WEST WALL FINISH PLAN NORTH WALL FINISH FLOOR FINISH ADDITIONAL FINISH NOTES PLAN EAST WALL FINISH 300 STOREFRONT TYPE TAG 9.6A-1 WALL'S FIRE RATING - HR UNIQUE WALL TYPE CONFIGURATION STRUCTURAL MATERIAL TYPE - CSI DIVISIONS STRUCTURAL MATERIAL WIDTH VICINITY MAP: REXBURG, IDAHO PROJECT LOCATION HWY 20 HWY 33 2N D E A S T MOODY ROAD DESIGN TEAM OWNER ARCHITECT CIVIL ENGINEERS LANDSCAPE ARCHITECT STRUCTURAL ENGINEERS MECHANICAL ENGINEERS ELECTRICAL ENGINEERS BEEHIVE FEDERAL CREDIT UNION CRAIG GUMMOW - CEO 1087 ERIKSON DRIVE REXBURG, IDAHO 83440 PHONE: (208) 656-1000 NBW ARCHITECTS P.A. 990 JOHN ADAMS PARKWAY IDAHO FALLS, IDAHO 83401 PHONE: (208) 522-8779 FAX: (208) 522-8785 CONNECT ENGINEERING 2295 N YELLOWSTONE HWY, STE #6 IDAHO FALLS, IDAHO 83401 PHONE: (208) 881-0081 BRECKON LAND DESIGN 6661 N. GLENWOOD ST GARDEN CITY, IDAHO 83714 PHONE: (208) 376-5153 FROST STRUCTURAL ENGINEERING 1020 E. LINCOLN RD. IDAHO FALLS, IDAHO 83401 PHONE: (208) 227-8404 ENGINEERED SYSTEMS ASSOCIATES 1355 EAST CENTER ST. POCATELLO, IDAHO 83201 PHONE: (208) 233-0501 FAX: (208) 233-0529 PAYNE ENGINEERING, INC. 1823 EAST CENTER ST. POCATELLO, IDAHO 83201 PHONE: (208) 232-4439 FAX: (208) 232-1435 ABBREVIATIONS # - NUMBER OR POUND & - AND A.F.F. - ABOVE FINISH FLOOR AL - ALUMINUM ALUM. - ALUMINUM B.O. - BOTTOM OF CMU - CONCRETE MASONRY UNIT CONC. - CONCRETE CONT. - CONTINUOUS DEMO. - DEMOLITION OR DEMOLISH DIA. - DIAMETER DN - DOWN EA. - EACH EIFS - EXTERIOR INSULATION & FINISHING SYSTEM ELEC. - ELECTRICAL ELEV. - ELEVATION EQ. - EQUAL EQUIP. - EQUIPMENT EXT. - EXTERIOR F.F. - FINISH FLOOR FRP - FIBERGLASS REINFORCED PLASTIC GA. - GAUGE GYP. - GYPSUM H.M. - HOLLOW METAL HR - HOUR HVAC - HEATING, VENTILATING, & AIR CONDITION I.D. - INSIDE DIAMETER I.M.P. - INSULATED METAL PANEL INSUL. - INSULATION INT. - INTERIOR MAX. - MAXIMUM MECH. - MECHANICAL MFR - MANUFACTURER MIN. - MINIMUM N.I.C. - NOT IN CONTRACT NO. - NUMBER O.C. - ON CENTER O.D. - OUTSIDE DIAMETER PLY - PLYWOOD PLUM. - PLUMBING PVC - POLYVINYL CHLORIDE RCP - REFLECTED CEILING PLAN REQ'D - REQUIRED SIM. - SIMILAR SPM - SINGLE PLY MEMBRANE STOR. - STORAGE STRUCT. - STRUCTURAL T.O. - TOP OF TYP. - TYPICAL U.N.O. - UNLESS NOTED OTHERWISE W/ - WITH W.C. - WATER CLOSET WD - WOOD I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 9 : 1 5 : 3 4 A M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t G1.0 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . GE N E R A L I N F O R M A T I O N APRIL 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 NEW BUILDING FOR: BEEHIVE FCU - NORTH REXBURG CORNER OF 2ND EAST AND MOODY RD. REXBURG, IDAHO 83440 CJR GLN DRAWING INDEX GENERAL G1.0 GENERAL INFORMATION G1.1 CODE ANALYSIS G1.2 ANSI STANDARDS CIVIL C1.00 COVER C2.00 NOTES C3.00 REFERENCE SHEET C4.00 EXISTING CONDITIONS C5.00 GENERAL LAYOUT C6.00 UTILITY LAYOUT C7.00 GRADING C8.00 DETAILS C9.00 DETAILS 2 C10.0 STORMTECH DETAILS C11.0 EROSION CONTROL LANDSCAPE L1.1 LANDSCAPE PLAN L1.5 LANDSCAPE DETAILS L2.1 IRRIGATION PLAN L2.5 IRRIGATION DETAILS L2.6 IRRIGATION DETAILS SITE DESIGN SP1.1 SITE PLAN - HORIZONTAL CONTROL SP2.1 SITE DETAILS SP2.2 SITE DETAILS SP2.3 SITE DETAILS ARCHITECTURAL A1.0 WALL AND ROOF TYPES A1.1 DIMENSION PLAN A1.2 ANNOTATION PLAN A1.3 REFLECTED CEILING PLAN A1.4 SIGNAGE, FLOOR FINISHED, AND DETAILS A1.5 OWNER FURNISHED PLAN A2.1 BUILDING ELEVATIONS A3.1 BUILDING SECTIONS A3.2 BUILDING SECTIONS A3.3 3D SECTIONS A4.1 WALL SECTION A4.2 WALL SECTIONS A4.3 WALL SECTIONS A4.4 ENLARGED SECTIONS AND ELEVATION A5.1 ENLARGED PLANS AND ELEVATIONS A5.2 ENLARGED PLANS, ELEVATIONS, AND SECTIONS A5.3 CASEWORK DETAILS A5.4 FLOOR PLAN DETAILS A6.1 DOOR SCHEDULE & ELEVATIONS A6.2 DOOR AND WINDOW DETAILS A7.1 ROOF PLAN A7.2 ROOF DETAILS PROJECT PERSPECTIVE DRAWING INDEX STRUCTURAL S1.0 GENERAL STRUCTURAL NOTES S1.1 SPECIAL INSPECTIONS S1.2 TYPICAL DETAILS S1.3 TYPICAL DETAILS S2.0 FOUNDATION PLAN S2.1 LOWER ROOF FRAMING PLAN S2.2 UPPER ROOF FRAMING PLAN S3.0 FOUNDATION DETAILS S3.1 FOUNDATION DETAILS S4.0 ROOF FRAMING DETAILS S4.1 ROOF FRAMING DETAILS S4.2 ROOF FRAMING DETAILS S4.3 ROOF FRAMING DETAILS MECHANICAL M1.0 MECHANICAL FOUNDATION PLAN M1.1 MECHANICAL FLOOR PLAN M2.1 MECHANICAL DETAILS M3.1 EQUIPMENT SCHEDULE AND DETAILS PLUMBING P1.0 PLUMBING FOUNDATION PLAN P1.1 PIPING FLOOR PLAN P2.1 PLUMBING DETAILS AND DIAGRAMS ELECTRICAL E0.0 ELECTRICAL SYMBOLS AND DETAILS E0.1 ELECTRICAL SITE PLAN E1.0 LIGHTING PLAN E2.0 POWER/DATA PLAN E3.0 POWER RISER AND SCHEDULE E3.1 ELECTRICAL SCHEDULES AND DETAILS Exit signs and Exit lighting to comply with 1008 and 1013. R e q u ire me nts on pg 7 0 are ab ov e and b e yond 2 017 N EC . P le ase v e rify with e ngine e r re q u ire me nts on plan are what he wants installe d. CODE ANALYSIS RELEVANT CODES: BUILDING/STRUCTURAL: 2018 IBC ELECTRICAL: 2017 NEC PLUMBING:2017 IPC MECHANICAL:2018 IMC FIRE:2018 IFC ENERGY:2018 IECC BUILDING OCCUPANCY: B -BUSINESS RISK CATEGORY (1604.5) RISK CATEGORY II CONSTRUCTION TYPE: TYPE V-B, NON-PROTECTED NON FIRE SPRINKLED ALLOWABLE HEIGHT AND AREA: ALLOWED STORIES -2 AREA -9,000 SQFT HEIGHT -40' ACTUAL STORIES -1 AREA -2,676 SQFT HEIGHT -21'-6" AREA BY OCCUPANCY GROUP: MAIN LEVEL B 2,676 SQFT TOTAL 2,676 SQFT FIRE RESISTANCE HOUR-RATING FOR BUILDING ELEMENTS (TABLE 601): TYPE V-B, ALL ELEMENTS -0-HR OCCUPANT EGRESS WIDTH: EGRESS WIDTH 29 X 0.2 = 5.8" REQ'D OR 36" MIN. -108" PROVIDED (1005.3.2) TRAVEL DISTANCE 200' MAXIMUM -72' ACTUAL COMMON PATH OL ≤30, NS = 100FT MAX. // ACTUAL = 37'-0" // NOTE: 2ND EXIT IS NOT REQ'D, BUT IS PROVIDED DEAD END CORRIDOR NOT APPLICABLE ADA TELLER SERVICE COUNTER:ADA MEMBERS TO RECEIVE BANKING SERVICES IN ADJACENT OFFICES WHERE DESKS MEET HEIGHT REQUIREMENT. BUILDING INFORMATION: HEIGHT OF BUILDING: 21'-6" NUMBER OF STORIES: 1 WATER CLOSET COUNT:(TOILET ROOMS TO UNISEX) OCC.LOAD CODE REQ'D PROVIDED B-MALE 14 1/25 (1st 50)1 1 B-FEMALE 15 1/25 1 1 LAVATORY COUNT: OCC.LOAD CODE REQ'D PROVIDED B-MALE 14 1/40 (1st 80)1 1 B-FEMALE 15 1/40 (1st 80)1 1 DRINKING FOUNTAIN COUNT: OCC.LOAD CODE REQ'D PROVIDED B 29 1/100 1 1 SERVICE SINK COUNT: OCC.LOAD CODE REQ'D PROVIDED B NA NA 1 1 ZONING REQUIREMENTS: LAND USE: CBC REQUIRED PARKING STALLS = 3 PARKING STALL PER 1000 SQ. FT. (2,676 / 1000) = 2.67 * 3 = 9 STALLS // ACTUAL PROVIDED = 25 STALLS REQUIRED ADA STALLS: 1 -25 = 1// ACTUAL PROVIDED = 1 ADA STALL 1B MANAGER 103 1B OFFICE 1 104 2B DRIVE-THRU 106 9A BREAK 107 1B TOILET 118 1B TOILET 117 1S I.T. 116 1S MECH. 111 1S JAN./STOR. 112 1B OFFICE 2 113 1B OFFICE 3 115 1B HALLWAY 108 7B MAIN LOBBY 102 17 12 1B VESTIBULE 101 OCCUPANCY LOAD PLAN KEY ACCESSORY 300 GROSS S BUSINESS 150 GROSS B ASSEMBLY 15 NET A A ROOM NAME ROOM # 30 FACTOR GROSS/ OCCUPANCY LOAD TYPE (SF) NET SYM. TOTAL EGRESS LOAD = 29 OCCUPANT LOAD (AREA / LOAD FACTOR) OCCUPANT LOAD TYPE SYMBOL 10 OCCUPANT LOAD SERVED BY EXIT I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 3 : 4 4 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t G1.1 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . CO D E A N A L Y S I S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE:3/16" = 1'-0" G1.1 1 CODE ANALYSIS T o b e v an acce ssib le . V e ntilation to prov ide d and comply with S e ction 12 03. C once ale d space s ne e d to hav e fire b lock ing and draft stopping installe d as pe r S e ction 7 18. N ot fe we r the n two drink ing fou ntains shall b e prov ide d. O ne for pe ople who u se whe e lchair and one for standing pe rson. S e ction 1109 .5 .1. 1 L1.5 2 L1.5 3 L1.5 4 L1.5 4 L1.5 5 L1.5 TYP. TYP. TYP. TYP. TYP. TYP. 3 L1.5 DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . N E W B U I L D I N G F O R : BE E H I V E F C U - N O R T H R E X B U R G 22021 BLD #23014 MARCH 2023 JB CP RE X B U R G , I D A H O 8 3 4 4 0 ww w . b r e c k o n l a n d d e s i g n . c o m Fa x : 2 0 8 - 3 7 6 - 6 5 2 8 Ph o n e : 20 8 - 3 7 6 - 5 1 5 3 66 6 1 N o r t h G l e n w o o d S t r e e t Ga r d e n C i t y , I d a h o 8 3 7 1 4 CA L L 2 B U S I N E S S D A Y S IN A D V A N C E B E F O R E YO U D I G , G R A D E , O R EX C A V A T E F O R T H E MA R K I N G O F UN D E R G R O U N D ME M B E R U T I L I T I E S Ca l l b e f o r e y o u d i g . Kn o w w h a t ' s b e l o w . R  I69: ÑKFÑJBFG: Ñ ÄÑ>EÑ;>IJKѤŽ–• 20 ' - 0 " 25 ' - 0 " 20 ' - 0 " 46'-6"66'-6"25'-0"20'-0" (TYP.) 9'-5" 8' - 7 " 26'-0"26'-0" 67 ' - 5 " 20 ' - 0 " 86'-6" 158'-0" 10 ' - 0 " 10 ' - 1 0 " 10'-0" 10'-7" 6' - 0 " 5' - 0 " 8' - 1 0 " 10'-0" 35 ' - 6 " 36 ' - 0 " 5' - 0 " 22 ' - 0 " 65 ' - 7 1 / 2 " 12 ' - 4 " 10 ' - 0 " (T Y P . ) R 7 . 5 ' R7.5 ' 6' - 0 " 6'-0" 6' - 6 " 15'-6" 9'-0"2'-0"9'-0"2'-0"9'-0"3'-6"10'-0" 32 ' - 2 " 1' - 1 1 " 1' - 1 1 " 4'-0" (TYP.) 19'-6" 15 ' - 8 " 12'-10"8'-1 1/2" 5'-0" 6'-6"11'-0"5'-0" 13'-9" 24 " 30 " 30 " 10'-0"4'-0"10'-0" 10'-0" R 1 0 . 0 ' SI T E P L A N - H O R I Z O N T A L C O N T R O L DRAWING NO.: CHECKED BY: DRAWN BY: DATE: PROJECT NO.: REVISIONS PR O J E C T : SH E E T T I T L E : BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : GLN 22021 APRIL 2023 CJR 04 - 0 6 - 2 0 2 3 NSCALE: SITE PLAN 1" = 10'-0"SP1.1 4 IFJJÑJBFGW ÑF;ÑJ>VW OSB@ JÑSEVÑ BSEV>EYJÑSKÑVFFIJÑEFKÑKFÑW P8W W Vѽ Ó • 66 4 3 11 2 A A B B DE E 5 C MECH. 111 JAN./STOR. 112 HALLWAY 108 BREAK 107 DRIVE-THRU 106 OFFICE 1 104 MANAGER 103 AA AA BB BB CC CC 3.5 4.8 1.5 R A7.2 SEE DETAIL ON /BA1.3 8'-7"C1 8'-7"C1 8'-7"C1 8'-0"C2 8'-0"C2 9'-0"C2 C3 VARY 8'-6"C1 TOILET 118 TOILET 117 I.T. 116 MAIN LOBBY 102 C3 VARY SEE DETAIL /BA1.3 C4 VARY C5 VARY C5 VA R Y C5 V A R Y C5 V A R Y C5 VARY C5 VARY C5 V A R Y C5 VARY C5 V A R Y C5 VARY A1.3 2 1'-6"7'-1 1/2"6"7'-1 1/2"6"7'-1 1/2"6"7'-1 1/2" 1'-6" 1'-6"7'-1 1/2"6"7'-1 1/2"6"7'-1 1/2"6"7'-1 1/2" C4 VARY C4 VARY C3 VARYC3VARYC3VARY C3 VARY C3 VARYC3 VARY C4 VARY 1' - 6 " 2 0 ' - 0 1 / 2 " 1 ' - 6 " 1 ' - 6 " 7 ' - 4 3 / 4 " 1 ' - 6 " A A1.3 A A1.3 9'-0"C2 C4 VARY A A1.3 CAMERA CAMERA FUTURE CAMERA 360 DEGREE CAMERA 360 DEGREE CAMERA SPEAKER AND VOLUME CONTROL CAMERA CAMERA CAMERA CAMERA CAMERAS 360 DEGREE CAMERA FUTURE CAMERA CAMERA CAMERA SPEAKER AND VOLUME CONTROL SPEAKER AND VOLUME CONTROL SPEAKER AND VOLUME CONTROL TWO SPEAKERS - HIGH ON THE WALL ABOVE OFFICES D.1 C.1 B.1 A1.3 1 SEE FOR LOWER CEILING PLAN SEE FOR LOWER CEILING PLAN 24x24 SREVICE ACCESS PANEL TO PNEUMATIC UNIT BLOWERS ABOVE SOFFIT -FIELD VERIFY LOCATION WITH DIEBOLD EQUIPMENT INSTALLERS CURVED WOOD BARREL TRUSS 5/8" GYP BOARD -- ATTACH TO BOTTOM CHORD 7/8" FURRING HAT CHANNEL 16" O.C. 1/2" PLYWOOD 1" 6" SEE STRUCTURAL FOR SPACING 2X4 BLOCKING BETWEEN TRUSSES TO SUPPORT ENDS OF CHANNEL (AS NEEDED). SHADOW JOINT PARALLEL TO TRUSS PERP. TO TRUSS PERP. EDGE DETAIL CURVED WOOD BARREL TRUSS 5/8" GYP BOARD -- ATTACH TO BOTTOM CHORD 7/8" FURRING HAT CHANNEL 16" O.C. 1/2" PLYWOOD 1" SHADOW JOINT 1/2" ZINTRA ACOUSTICAL PANEL FULLY ADHERED, BUTTED JOINTS AS REQ'D TO CONCEAL JOINTS 1" 1/2" ZINTRA ACOUSTICAL PANEL FULLY ADHERED, BUTTED JOINTS AS REQ'D TO CONCEAL JOINTS WALL OR STOREFRONT 1'-6" TO INSIDE FACEOF1" CEILING FINISH C1 2 X 4 LAY-IN ACOUSTICAL PANELS C2 GYPSUM BOARD OVER WOOD STUDS C3 ZINTRA ACOUSTICAL PANEL OVER CURVED PLYWOOD C4 GPYSUM BOARD DIRECT APPLICATION (PAINT) C5 PREFINISHED METAL SOFFIT C6 12 x 12 GLUE-UP ACOUSTICAL TILES CEILING SCHEDULE KEY C R O S S R U N N E R MAIN RUNNER 4 5 ° M A X . 1/2" CONDUIT COMPRESSION BRACE - FULL HEIGHT - TYP. VERTICAL WIRES AT 4'-0" O.C. 4 5 ° M A X . SPLAY WIRE AT 12'-0" O.C. IN EACH PLAN OF EACH RUNNER 2" MIN. SEISMIC CLIP 7/8" X 7/8" WALL MOLDING 3/4" CLEAR AT UNATTACHED END LATERAL FORCED BRACING REQUIRED FOR CEILING AREAS OVER 1,000 S.F. CEILING AREAS UNDER 1,000 S.F. ARE NOT. RIDGED BRACES MAY BE USED INSTEAD OF DIAGONAL SPLAY WIRES. A SEISMIC SEPARATION JOINT IS REQUIRED FOR CEILING AREAS GREATER THAN 2,500 S.F. MAIN OR CROSS RUNNER 8" MAX. 12 GA. WIRE OR APPROVED WALL SUPPORT PERIMETER SPACER AT UNATTACHED WALLS LATERAL FORCE BRACE DETAIL WALL MOLDING DETAIL 1 2 '-0 " T Y P . 6 '-0 " M A X .. 12'-0" TYP. 6'-0" MAX.. SUSPENSION SYSTEM LAYOUT NOT TO SCALE CEILING SUSPENSION SYSTEM FIRST LINE OF BRACING CEILING GRID SHALL BE ATTACHED TO WALL MOLDING AT TWO ADJACENT WALLS LATERAL FORCE BRACE DETAIL WALL MOLDING WALL MOLDING 4 3 E 5 OFFICE 2 113 OFFICE 3 115 10'-0"C6 10'-0"C6 FUTURE CAMERA FUTURE CAMERA SPEAKER AND VOLUME CONTROL SPEAKER AND VOLUME CONTROL SPEAKER AND VOLUME CONTROL 1'-0" 1' - 1 1 / 4 " PRE-FINISHED METAL SOFFIT 2X WOOD FRAMING FASTENED TO BOTTOM CORD FOR WOOD TRUSS 2X4 WOOD FRAMING 1/2" WOOD SHEATHING PRE-FINISHED METAL FASCIA PRE-FINISHED METAL SOFFIT 66 D C C5 VARY C5 VARY C5 VARY 360 DEGREE CAMERA HEIGHT STRIP CAMERA I D A H O FA L L S , O H A D I L E AR - 9 8 5 8 9 6 T A F F T E O F IN L GE S O S H L ADI T NO O R E NCIE S A D C I E T H C PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : 04 / 0 6 / 2 0 2 3 4/ 6 / 2 0 2 3 1 : 3 4 : 0 5 P M N : \ P r o j e c t s \ O t h e r \ B e e h i v e N o r t h Re x b u r g B r a n c h - N e w B l d g - 2 2 0 2 1 \ C A D \ D r a w i n g s \ B e e h iv e F C U N o r t h R e x b u r g v _ 2 3 . r v t A1.3 22021 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE F L E C T E D C E I L I N G P L A N MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 CJR GLN SCALE: N 1/4" = 1'-0" REFLECTED CEILING PLAN SCALE: 1 1/2" = 1'-0" A1.3 B DETAIL SCALE: 1 1/2" = 1'-0" CEILING GRID BRACING SCALE: 1/4" = 1'-0" A1.3 2 REFLECTED CEILING PLAN SCALE:1" = 1'-0" A1.3 A DETAIL SCALE: 1/4" = 1'-0" A1.3 1 REFLECTED CEILING PLAN S u spe nde d ce iling to b e installe d to manu factu re s spe cifications. CAST IN PLACE CENTERLINE CENTERLINE OF BEAM CENTERLINE OF COLUMN CENTERLINE OF WALL CLEAR CONCRETE CONCRETE CONTROL JOINT CONCRETE SAWCUT JOINT CONCRETE MASONRY UNIT CONNECTION CONTINUOUS DEAD LOAD DOWN DRAWING(S) EQUAL EQUIPMENT EXPANSION JOINT EACH WAY FINISHED FLOOR FACE OF STEEL FACE OF WALL GAUGE GALVANIZED GENERAL STRUCTURAL NOTES CENTERLINE OF FOOTING FACE OF MEMBER EXPANSION BOLT EDGE OF SLAB DIAMETER GALV. GSN DN. DWG(S) EQ. EQUIP. EXP. JT (E.J.) E.W. F.F. F.O.S. F.O.W. GA. F.O.M. EXP. BOLT E.O.S. o OR DIA. C.I.P. C.L. C.L.B. C.L.C. C.L.W. CLR CONC C.C.J. C.S.J. C.M.U. CONN. CONT. D.L. C.L.F. W/ WITH W/O WITHOUT T.O.P. U.N.O. W.W.F. TYP. VERT T.O.S. T.O.W. T.O.D. T.O.F. T.O.L. T.O.M. STD T.O.B. T.L. SLH SLV SIM. SQ. PSF PSI REINF. PREFAB OPP. P.C. PLF N.T.S. O.C. O.F.W. TOP OF FOOTING UNLESS NOTED OTHERWISE WELDED WIRE FABRIC TOP OF MASONRY TOP OF PLATE TOP OF STEEL TOP OF WALL TYPICAL VERTICAL STANDARD TOP OF BEAM TOP OF DECK TOP OF LEDGER TOTAL LOAD OUTSIDE FACE OF WALL PRECAST CONCRETE POUNDS PER LINEAR FOOT POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH SHORT LEG VERTICAL SHORT LEG HORIZONTAL REINFORCING SIMILAR SQUARE NOT TO SCALE ON CENTER OPPOSITE PREFABRICATED AGGREGATE BASE COURSE AIR CONDITIONER ABOVE FINISHED FLOOR ALTERNATE ANCHOR BOLT AT (MEASUREMENT) BEAM BOTTOM OF BEAM BOTTOM OF DECK BEARING BELOW FINISHED FLOOR BOTTOM OF FOOTING A.B.C. A/C A.F.F. ALT. A.B. @ BM B.O.B. B.O.D. BRG B.F.F B.O.F. ABBREVIATIONS LBS (#) MFR('S) M.C.J. MECH'L. N/A LLV LLH HORIZ. K(KIP) GLB (GLULAM) I.F.W. L.L. LONG LEG VERTICAL MANUFACTURER('S) MASONRY CONTROL JOINT NOT APPLICABLE LONG LEG HORIZONTAL GLUED-LAMINATED BEAM INSIDE FACE OF WALL POUNDS MECHANICAL HORIZONTAL 1000 POUNDS LIVE LOAD EXISTING(E) MIN. MINIMUM MAX. MAXIMUM SYMBOLS LEGEND WALLS WITH SOLID LINES DESIGNATE STRUCTURAL (BEARING) WALLS. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. WALLS WITH HATCH DESIGNATE MASONRY WALLS. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. 5 6 7 , , - AS SHOWN ON PLAN INDICATES A SHEARWALL HOLDOWN. SEE HOLDOWN SCHEDULES AND DETAILS FOR ADDITIONAL INFORMATION. A B INDICATES HVAC EQUIPMENT ON ROOF OR IN ATTIC SPACE. SEE TYPICAL DETAILS FOR FRAMING INFORMATION. - AS SHOWN ON PLAN INDICATES A HELICAL PIER. XXXX CS16, CMSTC16, ECT. - AS SHOWN AT WALL OPENINGS INDICATE STRAPPING, PROVIDE STRAPPING PER "TYPICAL STRAP AT OPENING" DETAIL. D=xxx# INDICATES DRAG LOAD (ASD) THAT TRUSS MANUFACTURER IS TO DESIGN TRUSS FOR IN BOTH TENSION AND COMPRESSION. STEP INDICATES STEPPED OR DEPRESSED SLAB. C=X" INDICATES CAMBER IN BEAM. INDICATES RIDGID CONNECTION. (NOT ALL SYMBOLS NECESSARILY APPLY TO THIS PROJECT) P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. SC1, SC2, ETC. - AS SHOWN ON PLAN INDICATES A STEEL COLUMN. SEE STEEL COLUMN SCHEDULE FOR ADDITIONAL INFORMATION. COLUMNS START AT THE LEVEL THEY ARE CALLED OUT ON. PX SCX RME XXX# N O TF O R C O N S T R U C T I O N P U R P O S E S PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : DBP 4/ 5 / 2 0 2 3 9 : 2 5 : 3 0 A M A u t o d e s k D o c s : / / 2 3 - 0 3 8 _ B e e h i v e F ed e r a l C r e d i t U n i o n R e x b u r g / I F 2 3 - 0 3 8 _ B e e h i v e F e d e r a l C r e d i t U n i o n R e x b u r g . r v t S1.0 23-038 BE E H I V E F C U -N O R T H R E X B U R G GE N E R A L S T R U C T U R A L N O T E S 02/23/2023 AV SHEET INDEX SHEET DESCRIPTION DETAILS S1.0 GENERAL STRUCTURAL NOTES --- S1.1 SPECIAL INSPECTIONS --- S1.2 TYPICAL DETAILS T - SERIES S1.3 TYPICAL DETAILS T - SERIES S2.0 FOUNDATION PLAN --- S2.1 LOWER ROOF FRAMING PLAN --- S2.2 UPPER ROOF FRAMING PLAN --- S3.0 FOUNDATION DETAILS 100 - SERIES S3.1 FOUNDATION DETAILS 100 - SERIES S4.0 ROOF FRAMING DETAILS 200 - SERIES S4.1 ROOF FRAMING DETAILS 200 - SERIES S4.2 ROOF FRAMING DETAILS 200 - SERIES S4.3 ROOF FRAMING DETAILS 200 - SERIES LOCATION LIVE / SNOW LOAD DEAD LOAD ELEMENTS LIVE LOAD TOTAL LOAD LOCATION:MINIMUM COVER TOLERANCE USE:CONCRETE STRENGTH: MAX W/C RATIO AIR ENTRAINMENT USE:MATERIAL: GENERAL REQUIREMENTS: BASIS FOR DESIGN: FOUNDATION NOTES:CONCRETE:WOOD:DEFERRED SUBMITTAL ITEMS: 1.THE STRUCTURAL SYSTEMS AND MEMBERS DEPICTED HEREIN HAVE BEEN DESIGNED PRIMARILY TO SAFEGUARD AGAINST MAJOR STRUCTURAL DAMAGE AND LOSS OF LIFE, NOT TO LIMIT DAMAGE OR MAINTAIN FUNCTION (IBC SECTION 101.3). 2.THESE DRAWINGS, AND THEIR ASSOCIATED STRUCTURAL CALCULATIONS, HAVE BEEN PERFORMED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE STRUCTURAL ENGINEER'S IN THIS OR SIMILAR LOCALITIES. THEY NECESSARILY ASSUME THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKMEN WHO HAVE A WORKING KNOWLEDGE OF THE INTERNATIONAL BUILDING CODE CONVENTIONAL FRAMING REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR FRAMING ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, IT IS UNDERSTOOD THAT THE CONTRACTOR WILL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR ALL MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3.THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION SUCH THAT DESIGN LIVE LOAD PER SQUARE FOOT AS STATED HEREIN IS NOT EXCEEDED. OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF AN OPTION IS USED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES, AND SHALL COORDINATE ALL DETAILS. 4.WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. TYPICAL DETAILS AND NOTES ARE NOT NECESSARILY INDICATED ON THE PLANS, BUT SHALL APPLY NONE-THE-LESS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. DETAILS MAY SHOW ONLY ONE SIDE OF CONNECTION OR MAY OMIT INFORMATION FOR CLARITY. 5.ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ARCHITECT AND STRUCTURAL ENGINEER. 6.ANY INSPECTIONS, SPECIAL (IBC CHAPTER 17) OR OTHERWISE THAT ARE REQUIRED BY THE BUILDING CODES, LOCAL BUILDING DEPARTMENTS, OR BY THESE PLANS SHALL BE DONE BY AN INDEPENDENT INSPECTION COMPANY OR THE BUILDING DEPARTMENT, SITE VISITS BY THE STRUCTURAL ENGINEER DO NOT CONSTITUTE AN OFFICIAL INSPECTION, UNLESS SPECIFICALLY CONTRACTED FOR. 1.BUILDING CODE: 2018 EDITION OF THE IBC WITH CITY/COUNTY AMENDMENTS. RISK CATEGORY = II 4. SEISMIC DESIGN PARAMETERS: ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE IMPORTANCE FACTOR Ie = 1.00 SEISMIC DESIGN CATEGORY D MAPPED SPECTRAL RESPONSE ACCELERATIONS S1 = 0.143, SS = 0.367 DESIGN SPECTRAL RESPONSE ACCELERATIONS PERCENT SNOW INCLUDED WITH SEISMIC LOADS 20 VERTICAL SHEAR TRANSFER ELEMENTS: AT BUILDING: PLYWOOD SHEARWALL(S) AT DRIVE-THRU: STEEL ORDINARY CANTILEVERED COLUMNS R = 6.5, CS = 0.057 5. WIND DESIGN PARAMETERS (STRENGTH): ULTIMATE WIND SPEED 115 MPH (3 SECOND GUST) WIND EXPOSURE C IMPORTANCE FACTOR Iw = 1.00 INTERNAL PRESSURE COEFFICIENT -0.18 COMPONENT AND CLADDING PRESSURE 27.2 PSF NET UPLIFT ON ROOF 26.5 PSF 2. VERTICAL LOADS: ROOF ROOF = 35 PSF GROUND = 50 PSF 20 PSF 3. DEFLECTION LIMITS: ROOF TRUSSES/JOISTS L/360 L/240 BEAMS L/360 L/240 3.A ONE-THIRD INCREASE IN BEARING PRESSURES IS ALLOWED WITH SEISMIC OR WIND LOAD COMBINATIONS. LATERAL BEARING AND LATERAL SLIDING RESISTANCE MAY BE COMBINED. 4.ALL FOUNDATIONS SHALL BEAR ON COMPACTED ENGINEERED FILL OR COMPETENT NATIVE SOIL SUBBASE COMPACTED TO 95% DRY DENSITY (STANDARD PROCTOR). GRADE IS DEFINED AS LOWEST ADJACENT GRADE WITHIN 5 FEET OF THE BUILDING FOR PERIMETER FOOTINGS. WHERE EXTERIOR PAVING OR CONCRETE IS DIRECTLY ADJACENT TO BUILDING, GRADE IS DEFINED AS TOP OF EXTERIOR PAVING AT LEAST 5 FEET FROM BUILDING. CONCRETE FOOTING EXCAVATIONS SHALL BE CLEAN AND FREE OF LOOSE DEBRIS OR UN-COMPACTED MATERIAL AT TIME OF CONCRETE PLACEMENT. 5.CONCRETE SLABS ON GRADE SHALL BE SUPPORTED ON A 4 INCH (MIN) LAYER OF FREE-DRAINING GRANULAR MAT (DRAINAGE FILL COURSE). THE MAT SHOULD CONSIST OF A WELL GRADED SAND AND GRAVEL MIXTURE WITH MAXIMUM 3/4-INCH CRUSHED AGGREGATE. THE GRANULAR MAT SHOULD BE COMPACTED TO NO LESS THAN 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D1557. 6.BACKFILL AGAINST RESTRAINED WALLS SHALL NOT BE PLACED UNTIL AFTER THE WALLS ARE SUPPORTED BY THE COMPLETION OF INTERIOR FLOOR SYSTEMS AND CONCRETE OR GROUT STRENGTH HAS REACHED THE 28 DAY STRENGTH LISTED BELOW. THE SOIL DESIGN VALUES FOR THE FOUNDATION ARE: ALLOWABLE BEARING PRESSURE 2500 PSF ALLOWABLE LATERAL BEARING PRESSURE 100 PSF/FT ALLOWABLE LATERAL SLIDING COEFFICIENT 0.25 FOUNDATION BEARING DEPTH 36" BELOW FINISHED GRADE 2.ALL NORMAL WEIGHT CONCRETE SHALL BE REGULAR WEIGHT OF 150 POUNDS PER CUBIC FOOT USING HARD ROCK AGGREGATES. AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. . 3.LAP SPLICES FOR BEAMS AND FLOOR SLABS SLABS SHALL BE ACCORDING TO CHAPTER 12 OF ACI 318 OR LAP SCHEDULE ON THESE DRAWINGS. STAGGER SPLICES A MINIMUM OF ONE LAP LENGTH. NO TACK WELDING OF REINFORCING BARS ALLOWED WITHOUT PRIOR REVIEW OF PROCEDURE WITH THE STRUCTURAL ENGINEER. LATEST ACI CODE AND DETAILING MANUAL APPLY. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. VERTICAL WALL BARS SHALL BE SPLICED AT OR NEAR FLOOR LINES. 4.ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING STEEL NOT NOTED AS "CLEAR" OR "CLR" ARE TO CENTER OF STEEL. MINIMUM COVER FOR NON-PRESTRESSED CONCRETE REINFORCING SHALL BE AS FOLLOWS: 5.MAXIMUM SLUMP FOR ALL CONCRETE SHALL BE 6". PORTLAND CEMENT SHALL CONFORM TO ASTM C150. TYPE V CEMENT SHALL BE USED FOR CONCRETE IN CONTACT WITH ALKALINE SOIL, AND TYPE II ELSEWHERE. 6.NO MORE THAN 90 MINUTES SHALL ELAPSE BETWEEN CONCRETE BATCHING AND CONCRETE PLACEMENT UNLESS APPROVED BY THE TESTING AGENCY. 7.CONCRETE PLACEMENT AND QUALITY SHALL BE PER RECOMMENDATIONS IN ACI 614, ACI 301 AND ACI 318. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS ON GRADE NEED BE VIBRATED ONLY AROUND AND UNDER FLOOR DUCTS, ETC. CAST CLOSURE POUR, WHERE SHOWN ON PLANS AROUND COLUMNS AFTER COLUMN DEAD LOAD IS APPLIED. REMOVE ALL DEBRIS FROM FORMS BEFORE PLACING CONCRETE. ALL ITEMS TO BE CAST IN CONCRETE SUCH AS REINFORCING, DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY POSITIONED IN THE FORMS BEFORE PLACING THE CONCRETE. 8.ALL CONCRETE SLABS ON GRADE SHALL BE DIVIDED INTO AREAS BY CONTROL JOINTS (KEYED OR SAW CUT) SUCH THAT ONE SLAB AREA DOES NOT EXCEED A MAXIMUM LENGTH OF 24 TIMES THE SLAB THICKNESS IN BOTH DIRECTIONS (EXAMPLE: 4" SLAB = 8'-0" LENGTH). SQUARE LAYOUTS ARE PREFERRED, BUT THE SLAB GEOMETRY MAY DICTATE OTHERWISE. THE RATIO OF THE LONG TO SHORT DISTANCE SHALL NOT EXCEED 1.3. IT IS RECOMMENDED THAT SAW CUTS BE MADE WITHIN 16 HOURS OF CONCRETE BATCHING. KEYED CONTROL JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING POURING, ALL OTHER JOINTS MAY BE SAW CUT. 9.HORIZONTAL PIPES AND ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE AND SLABS ON GRADE EXCEPT WHERE SPECIFICALLY APPROVED OR NOTED BY THE STRUCTURAL ENGINEER. PIPES AND CONDUITS SHALL NOT IMPAIR THE STRENGTH OF THE WORK. 10. FLY ASH MAY BE USED ONLY IF PERMITTED BY ARCHITECTURAL SPECIFICATIONS AND SHALL BE LIMITED TO 18 PERCENT OF CEMENTITIOUS MATERIALS AND SHALL HAVE A REPLACEMENT FACTOR OF 1.2 RELATIVE TO CEMENT REPLACED. NO FLY ASH ADDITIVES SHALL BE USED IN FLATWORK OR ARCHITECTURALLY EXPOSED CONCRETE. 11.COLD/HOT WEATHER CONCRETE CONSTRUCTION: PROTECT CONCRETE FROM DAMAGE OR REDUCED STRENGTH IN COMPLIANCE WITH ACI 305 AND 306. 12.CONCRETE MIXES SHALL BE DESIGNED BY A CERTIFIED LABORATORY AND APPROVED BY THE STRUCTURAL ENGINEER. 13.LIMIT ALKALI-SILICA REACTION (ASR) TO 0.1% EXPANSION AT 28 DAYS IN CONCRETE MIX AT ALL EXTERIOR CONCRETE AND INTERIOR CONCRETE EXPOSED TO MOISTURE. CAST AGAINST EARTH (FOOTINGS)3"± 3/8" SLABS ON GRADE 1 1/2" EXPOSED TO EARTH OR WEATHER - #5 AND SMALLER EXPOSED TO EARTH OR WEATHER - #6 AND LARGER 2" NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND ROOF SLAB 1" STRUCTURAL SLABS AND WALLS BEAMS AND COLUMNS (PRIMARY) REINFORCEMENT, TIES, STIRRUPS AND SPIRALS 1. MINIMUM 28 DAY CONCRETE STRENGTH SHALL BE AS FOLLOWS: FOOTINGS 3500 PSI 0.50 5.5% ± 1% FOUNDATION WALLS 4500 PSI 0.45 5.5% ± 1% INTERIOR CONCRETE SLABS ON GRADE 3500 PSI 0.45 N/A 1.GENERAL: DO NOT NOTCH OR DRILL JOISTS, BEAMS, OR LOAD BEARING STUDS WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER THROUGH THE ARCHITECT. DOUBLE UP JOISTS AND BLOCKING UNDER PARTITIONS. PROVIDE 2" (NOMINAL) SOLID BLOCKING AT SUPPORTS OF ALL JOISTS. UNLESS NOTED OTHERWISE ON PLANS/DETAILS PROVIDE 2x SOLID BLOCKING AT MID-HEIGHT OF BEARING STUD WALLS. ALL NAILING NOT NOTED SHALL BE ACCORDING TO IBC TABLE 2304.10.1. JOIST HANGERS AND OTHER MISC. FRAMING ANCHORS SHALL BE SIMPSON STRONG-TIE COMPANY, INC. OR OTHER MANUFACTURER WITH CURRENT ICC-ES APPROVAL. 2.SAWN LUMBER: FRAMING LUMBER SHALL COMPLY WITH THE LATEST EDITION OF THE GRADING RULES OF THE WESTERN WOOD PRODUCTS ASSOCIATION (WWPA) OR THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB). ALL SAWN LUMBER SHALL BE STAMPED WITH THE GRADE MARK OF AN APPROVED LUMBER GRADING AGENCY. SAWN LUMBER SHALL HAVE THE FOLLOWING MINIMUM GRADE UNLESS NOTED OTHERWISE IN SCHEDULES: 2x4 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) 2x6 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) JOISTS, TOP PLATES AND ALL OTHER SAWN LUMBER DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) BEAMS AND POSTS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) LOCATION:NOMINAL THICKNESS: SPAN INDEX RATING: EDGE ATTACHMENT: FIELD ATTACHMENT: WALL 8d AT 6" O.C. 8d AT 12" O.C. ROOF 8d AT 6" O.C. 8d AT 12" O.C. ROOF 8d AT 6" O.C. 8d AT 12" O.C. ROOF 10d AT 6" O.C.10d AT 12" O.C. ROOF 10d AT 6" O.C. 10d AT 12" O.C. ROOF 10d AT 6" O.C. 10d AT 12" O.C. FLOOR 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. 3. PLYWOOD: ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING CONFORMING TO STANDARD PS 1-95. LAY UP PLYWOOD WITH FACE GRAIN IN PERPENDICULAR TO SUPPORTS (ON ROOFS WHERE PLYWOOD IS LAID UP WITH FACE GRAIN PARALLEL TO SUPPORTS, USE A MINIMUM OF 5-PLY PLYWOOD, STAGGER JOINTS). ALL NAILING, COMMON NAILS. BLOCKING AT PANEL EDGES WHERE INDICATED ON PLANS. ALL PLYWOOD SHALL BE OF THE FOLLOWING NOMINAL THICKNESS, SPAN/INDEX RATING AND SHALL BE NAILED AS FOLLOWS UNLESS NOTED OTHERWISE ON THE PLANS: SCREWS AT FLOOR SHEATHING SHALL BE #8 SCREWS AND SHALL PENETRATE AT LEAST 1 1/2" INTO THE SUPPORTING MEMBER. ALL FLOOR SHEATHING SHALL BE GLUED TO SUPPORTING MEMBERS WITH AN APA AFG-01 QUALIFIED ADHESIVE. PLYWOOD ALTERNATE: AMERICAN PLYWOOD ASSOCIATION PERFORMANCE RATED SHEATHING MAY BE USED AS AN ALTERNATE TO PLYWOOD WITH PRIOR APPROVAL OF OWNER, ARCHITECT AND ROOFER. IT MAY NOT BEUSED ON ROOFS WHERE BUILT UP ROOF SYSTEM IS TO BE GUARANTEED BY ROOFER. RATED SHEATHING SHALL COMPLY WITH CURRENT ICC-ES REPORTS AND SHALL HAVE A SPAN RATING EQUIVALENT TO OR BETTER THAN THE PLYWOOD IT REPLACES. ATTACHMENT AND THICKNESS (WITHIN 1/32") SHALL BE THE SAME AS THE PLYWOOD IT REPLACES. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 4.NOMINAL 2x AND 3x DECKING. TONGUE AND GROOVE TYPE. MINIMUM Fb = 1,600 PSI, MINIMUM E = 1,300,000 PSI. INSTALL WITH TONGUES UP SLOPE ON PITCHED ROOFS, AND OUTWARD IN THE DIRECTION OF LAYING ON FLAT ROOFS. NAIL EACH PLANK WITH 16d TOENAIL (THRU THE TONGUE) AND 16d FACE NAIL AT EACH SUPPORT. DECK SHALL BE INSTALLED AS SIMPLE SPAN WITH ALL PLANKS BEARING ON TWO SUPPORTS. FOR REFERENCE AND/OR ADDITIONAL INFORMATION SEE AITC 117-2010. 5.GLUED-LAMINATED BEAMS (GLB): GLUED-LAMINATED BEAMS SHALL BE DOUGLAS FIR COMBINATION AT 24F-V4 AT SIMPLE SPAN BEAMS AND 24F-V8 AT MULTI-SPAN AND CANTILEVERED BEAMS WITH THE FOLLOWING MINIMUM PROPERTIES: FB = 2,400 PSI, FV = 190 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,800 KSI. ALL BEAMS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. BEAMS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. CAMBER AS SHOWN ON DRAWINGS. STANDARD CAMBER IS BASED ON A RADIUS OF CURVATURE OF 2000 FEET. 6.GLUED-LAMINATED COLUMNS: GLUED-LAMINATED COLUMNS SHALL BE DOUGLAS FIR COMBINATION 3 WITH THE FOLLOWING MINIMUM PROPERTIES: FBY = 2,100 PSI, FBX = 2000 PSI, FVY = 230 PSI, FVX = 265 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,900 KSI. ALL COLUMNS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. COLUMNS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. 7.LAMINATED VENEER LUMBER (LVL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LVLs SHALL BE: FB = 2,600 PSI, FV = 285 PSI, E = 2,000 KSI. 8.PARALLEL STRAND LUMBER (PSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR PSLs SHALL BE: FB = 2,900 PSI, FV = 290 PSI, E = 2,000 KSI. 9.LAMINATED STRAND LUMBER (LSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LSLs SHALL BE: FB = 2,325 PSI, FV = 310 PSI, E = 1,550 KSI. 10.SILL PLATES RESTING ON CONCRETE OR MASONRY SHALL BE OF TREATED FIR. SHEAR WALLS AND EXTERIOR WALL SILLS AT CONCRETE SLAB SHALL HAVE A MINIMUM OF (2) ANCHOR BOLTS PER PIECE. PROVIDE ANCHOR BOLT AT 9" MAXIMUM, 4" MINIMUM FROM THE END OF EACH PIECE AT SPLICE OR END OF WALL. MAXIMUM ANCHOR BOLT SPACING SHALL BE 72" ON CENTER UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. ALL ANCHOR BOLTS (OTHER THAN BOLTS FOR HOLDOWNS) SHALL EMBED 7" INTO CONCRETE. ANCHOR BOLTS FOR HOLDOWNS SHALL NOT BE CONSIDERED AS PART OF REQUIRED ANCHOR BOLTS ON SHEAR WALLS. ALL EXTERIOR WALLS SHALL BE SECURED WITH MINIMUM ANCHOR BOLTS. INTERIOR WALLS MAY BE SECURED TO CONCRETE WITH EITHER ANCHOR BOLTS OR POWER DRIVEN SHOT PINS UNLESS NOTED OTHERWISE ON PLANS. 11.BOLTING: ALL BOLTS IN WOOD CONNECTIONS SHALL CONFORM TO ASTM A307. BOLTS SHALL BE INSTALLED IN HOLES BORED WITH A BIT 1/16" LARGER THAN THE Ø (DIAMETER) OF THE BOLT. BOLTS AND NUTS SEATING ON WOOD SHALL HAVE CUT STEEL WASHERS UNDER HEADS AND NUTS. NICK THREADS TO PREVENT LOOSENING. 12. OPEN-WEB WOOD ROOF TRUSSES SD1 = 0.221, SDS = 0.369 GENERAL STRUCTURAL NOTES (APPLY UNLESS NOTED OTHERWISE ON PLANS/DETAILS) ± 1/4" 1 1/2" ± 3/8" ± 3/8" 1/8" 3/4"1/8" 1 1/2" 3/8" PREFABRICATED WOOD TRUSSES: PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED TO SUPPORT SELF WEIGHT PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS. WHERE UNINHABITABLE ATTIC SPACE CAN BE USED FOR STORAGE, A 20 PSF LIVE LOAD ON THE BOTTOM CHORD SHALL BE INCLUDED IN THE ANALYSIS. BRIDGING SIZE AND SPACING BY TRUSS MANUFACTURER UNLESS NOTED OTHERWISE. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED ENGINEER FOR REVIEW PRIOR TO MANUFACTURE FOR BOTH ROOF AND FLOOR TRUSSES WHEN USED. SHOP DRAWINGS SHALL SHOW ANY SPECIAL DETAILS REQUIRED AT BEARING POINTS. ALL CONNECTORS SHALL HAVE CURRENT ICC-ES APPROVAL. ADDITIONAL TRUSSES SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. PER IBC SECTION 2303.4 AND TPI-1: EACH TRUSS SHALL BE LEGIBLY BRANDED, MARKED OR OTHERWISE HAVE PERMANENTLY AFFIXED THERETO THE IDENTITY OF THE COMPANY MANUFACTURING THE TRUSS, THE DESIGN LOADS, AND THE TRUSS SPACING - WITHIN TWO FEET OF THE CENTER OF THE SPAN ON THE FACE OF THE BOTTOM CHORD. PREFABRICATED WOOD/STEEL WEB JOIST/PURLINS (TJI/TJL SERIES OR EQUAL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST EDITION ICC-ES REPORT. CONNECTIONS AND BEARING MATERIAL TO BE DESIGNED AND FURNISHED BY JOIST FABRICATOR. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED STRUCTURAL ENGINEER FOR REVIEW PRIOR TO MANUFACTURE. ADDITIONAL JOISTS SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. 7/16" OR 1/2" 7/16" OR 1/2" 15/32" OR 1/2" 19/32" OR 5/8" 23/32" OR 3/4" 7/8" 3/4" T&G 7/8" T&G 1 1/8" T&G 24/16 24/16 32/16 40/20 48/24 60/32 48/24 60/32 60/48 1. 2.SITE PREPARATION AND GRADING REQUIREMENTS OF THE SOIL REPORT AND ANY ADDENDUM'S SHALL BE COMPLETED PRIOR TO CONSTRUCTION OF FOUNDATIONS. ANY TESTS OR INSPECTIONS REQUIRED BY THE SOIL REPORT SHALL BE PERFORMED PRIOR TO PLACEMENT OF FOUNDATION REINFORCING STEEL OR CONCRETE. ALTERATIONS TO SITE PREPARATION OR GRADING SHALL BE REPORTED TO THE GEOTECHNICAL ENGINEER PRIOR TO FOUNDATION CONSTRUCTION. FOUNDATIONS DESIGNED IN CONFORMANCE WITH RECOMMENDATIONS BY: XCELL ENGINEERING, LLC. REPORT NO. P22296 DATED DECEMBER 14, 2022. REINFORCING STEEL: 1.ASTM A615 GRADE 60 (FY = 60 KSI) DEFORMED BARS FOR ALL BARS #4 AND LARGER. ASTM A615 GRADE 40 (FY = 40 KSI) DEFORMED BARS FOR ALL BARS #3 AND SMALLER. GRADE 60 DEFORMED BARS SHALL BE USED FOR CONCRETE WALLS, BEAMS, AND ELEVATED SLAB REINFORCING. 2.WELDING OF REINFORCING BARS SHALL BE MADE ONLY TO ASTM A706 GRADE 60 BARS AND ONLY USING E90 SERIES RODS. WELDING OF REINFORCING BARS SHALL BE MADE ONLY AT LOCATIONS SHOWN ON PLANS OR DETAILS. 3.REINFORCING BAR SPACING GIVEN ARE MAXIMUM ON CENTERS. ALL BARS PER CRSI SPECIFICATIONS AND HANDBOOK. DOWEL ALL VERTICAL REINFORCING TO FOUNDATION. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. STEEL: 1. MATERIALS: ROLLED W SHAPES, SHALL CONFORM TO ASTM A992 (FY=50 KSI). ALL OTHER STRUCTURAL STEEL SHAPES, ROLLED SECTIONS, BARS AND PLATES SHALL CONFORM TO ASTM A36 (FY = 36 KSI). ALL PIPE STEEL SHALL BE ASTM A501 (FY = 36 KSI) OR ASTM A53, TYPE E OR S, GRADE B (FY = 35 KSI). ALL TUBULAR STEEL SHALL BE ASTM A500 (FY = 46 KSI). 2.ALL BOLTS AND STUDS SHALL BE ASTM A307, UNLESS NOTED OTHERWISE. ALL EXPANSION BOLTS TO HAVE CURRENT ICC REPORT RATING FOR MATERIAL INTO WHICH INSTALLATION TAKES PLACE. HEADED STUDS SHALL CONFORM TO ALL REQUIREMENTS OF THE LATEST EDITION OF THE "RECOMMENDED PRACTICES FOR STUD WELDING" AND THE "STRUCTURAL WELDING CODE" PUBLISHED BY AWS. ALL BOLTS, ANCHOR BOLTS, EXPANSION BOLTS, ETC. SHALL BE INSTALLED WITH STEEL WASHERS AT FACE OF WOOD OR AT SLOTTED HOLES IN STEEL SECTIONS. 3. ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH AISC SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, LATEST EDITION. 4.WELDING SHALL BE BY WELDERS HOLDING VALID CERTIFICATES AND HAVING CURRENT EXPERIENCE IN THE TYPE OF WELD SHOWN ON THE DRAWINGS OR NOTES. ALL WELDING SHALL USE E70 SERIES LOW HYDROGEN RODS UNLESS NOTED OTHERWISE. ALL WELDING PER LATEST AMERICAN WELDING SOCIETY STANDARDS. ALL WELDS ON DRAWINGS ARE SHOWN AS SHOP WELDS. CONTRACTOR MAY SHOP WELD OR FIELD WELD AT HIS DISCRETION. ALL FULL PENETRATION WELDS SHALL BE TESTED AND CERTIFIED BY AN INDEPENDENT TESTING LABORATORY. 5.STEEL TO STEEL BOLTED CONNECTIONS: HIGH STRENGTH BOLTS SHALL BE ASTM A325N AND SHALL BE INSTALLED AS BEARING-TYPE CONNECTIONS WITH THREADS INCLUDED IN SHEAR PLANE (TYPE "N" CONNECTION UNLESS NOTED OTHERWISE). BOLTS MAY BE TIGHTENED USING ANY AISC APPROVED METHOD. 6. DRYPACK SHALL BE 5,000 PSI FIVE STAR NON-SHRINK GROUT OR EQUIVALENT. INSTALL DRYPACK UNDER BEARING PLATES BEFORE FRAMING MEMBER IS INSTALLED. AT COLUMNS, INSTALL DRYPACK UNDER BASE PLATES AFTER COLUMN HAS BEEN PLUMBED BUT PRIOR TO FLOOR OR ROOF INSTALLATION. 7.SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS IN ADDITION TO ITEMS REQUIRED BY ARCHITECTURAL SPECIFICATIONS, THE CONTRACTOR SHALL REVIEW ALL SHOP DRAWINGS PRIOR TO SUBMITTAL. ITEMS NOT IN ACCORDANCE WITH CONTRACT DRAWINGS SHALL BE FLAGGED UPON HIS REVIEW. VERIFY ALL DIMENSIONS WITH ARCHITECT. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM ORIGINAL CONTRACT DRAWINGS SHALL BE CLOUDED. ANY OF THE AFOREMENTIONED WHICH ARE NOT CLOUDED OR FLAGGED BY SUBMITTING PARTIES, SHALL NOT BE CONSIDERED APPROVED AFTER THE STRUCTURAL ENGINEER'S REVIEW, UNLESS NOTED ACCORDINGLY. ANY ENGINEERING PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW, SHALL BEAR THE SEAL OF A STRUCTURAL ENGINEER REGISTERED IN THE APPROPRIATE STATE. THE SHOP DRAWINGS DO NOT REPLACE THE ORIGINAL CONTRACT DRAWINGS. ITEMS OMITTED OR SHOWN INCORRECTLY AND ARE NOT FLAGGED BY THE STRUCTURAL ENGINEER ARE NOT TO BE CONSIDERED CHANGES TO ORIGINAL DRAWINGS. THE ADEQUACY OF ENGINEERING DESIGNS AND LAYOUT PERFORMED BY THE OTHERS RESTS WITH THE DESIGNING OR SUBMITTING AUTHORITY. REVIEWING IS INTENDED ONLY AS AN AID TO THE CONTRACTOR IN OBTAINING CORRECT SHOP DRAWINGS. RESPONSIBILITY FOR CORRECTNESS SHALL REST WITH THE CONTRACTOR. ALLOW (5) WORKING DAYS FOR THE STRUCTURAL ENGINEER'S REVIEW. ONE COPY OF EACH SUBMITTAL WILL BE RETAINED FOR THE STRUCTURAL ENGINEER'S RECORDS. BRICK VENEER ANCHORAGE: BRICK VENEER ANCHOR CLIPS, ANCHORS, AND ATTACHEMENTS SHALL BE HOT-DIPPED GALVANIZED AND EITHER OF THE FOLLOWING FROM HOHMANN & BARNARD, INC. OR APPROVED EQUAL: 1.DW-10HS W/ S.I.S. (SEISMICLIP INTERLOCKING SYSTEM) SEISMIC VENEER ANCHORS 2.345-BT W/ S.I.S. (SEISMICLIP INTERLOCKING SYSTEM) SEISMIC VENEER ANCHORS INSTALLATION: 3.CLIPS SHALL BE ATTACHED AT 24" O.C. HORIZONTAL AND 16" O.C. VERTICAL (MAX) USING #10 HOT-DIPPED GALVANIZED SCREWS. 4. WHERE WOOD BACKUP IS USED, PROVIDE SHEATHING AND WATERPROOFING AS REQUIRED. 5.PROVIDE CONTINUOUS HOT-DIPPED GALVANIZED WIRE (9-GAUGE OR 3/16"Ø) ATTACHED TO EACH CLIP. R = 1.25, CS = 0.295 fax: 208.227.8405 1020 E. Lincoln Road Structural Engineering Idaho Falls, ID 83401 phone: 208.227.8404 info@frost-structural.com FROST S tampe d Engine e re d roof tru sse s approv e d b y B u ilding D e sign P rofe ssional ne e de d whe n re ce iv e d. N O TF O R C O N S T R U C T I O N P U R P O S E S PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : DBP 4/ 5 / 2 0 2 3 9 : 2 5 : 3 0 A M A u t o d e s k D o c s : / / 2 3 - 0 3 8 _ B e e h i v e F ed e r a l C r e d i t U n i o n R e x b u r g / I F 2 3 - 0 3 8 _ B e e h i v e F e d e r a l C r e d i t U n i o n R e x b u r g . r v t S1.1 23-038 BE E H I V E F C U -N O R T H R E X B U R G SP E C I A L I N S P E C T I O N S 02/23/2023 AV VERIFICATION AND INSPECTION OF STRUCTURAL STEEL VERIFICATION AND INSPECTION OB S E R V E PE R F O R M 1. INSPECTION TASKS PRIOR TO WELDING (TABLE N5.4-1) A. WELDER QUALIFICTION RECORDS AND CONTINUITY RECORDS X B. WELDING PROCEDURE SPECIFICATIONS (WPS) AVAILABLE X C. MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE X D. MATERIAL IDENTIFICATION (TYPE/GRADE)X E. WELDER IDENTIFICATIONS SYSTEM (THE FABRICATOR OR ERECTOR, AS APPLICABLE, SHALL MAINTAIN A SYSTEM BY WHICH A WELDER WHO HAS WELDED A JOINT OR MEMBER CAN BE IDENTIFIED. (STAMPS, IF USED, SHALL BE THE LOW STRESS TYPE) X F. FIT-UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY), JOINT PREPARATION, DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL), CLEANLINESS (CONDITION OF STEEL SURFACES), TACKING (TACK WELD QUALITY AND LOCATION) , BACKING TYPE AND FIT (IF APPLICABLE) X G. FIT-UP OF CJP GROOVE WELDS OF HSS T-, Y- AND K-JOINTS WITHOUT BACKING (INCLUDING JOINT GEOMETRY), JOINT PREPARATIONS, DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL), CLEANLINESS (CONDITION OF STEEL SURFACES), TACKING (TACK WELD QUALITY AND LOCATION X H. CONFIGURATION AND FINISH OF ACCESS HOLES X I. FIT-UP OF FILLET WELDS, DIMENSIONS (ALIGNMENT, GAPS AT ROOT), CLEANLINESS (CONDITION OF STEEL SURFACES) TACKING (TACK WELD QUALITY AND LOCATION) X J. CHECK WELDING EQUIPMENT - - 2. INSPECTION TASKS DURING WELDING (TABLE N5.4-2) A. CONTROL AND HANDLING OF WELDING CONSUMABLES, PACKAGING, EXPOSURE CONTROL X B. NO WELDING OVER CRACKED TACK WELDS X C. ENVIRONMENTAL CONDITIONS, WIND SPEED WITHIN LIMITS, PRECIPITATION AND TEMPERATURE X D. WELDING PROCEDURE SPECIFICATIONS (WPS) FOLLOWED, SETTINGHS ON WELDING EQUIPMENT, TRAVEL SPEED, SELECTED WELDING MATERIALS, SHIELDING GAS TYPE/FLOW RATE, PREHEAT APPLIED, INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.), PROPER POSITION (F, V, H, OH) X E. WELDING TECHNIQUES, INTERPASS AND FINAL CLEANING, EACH PASS WITHIN PROFILE LIMITATIONS, EACH PASS MEETS QUALITY REQUIREMENTS X F. PLACEMENT AND INSTALLATION OF STEEL HEADED STUD ANCHORS X 3. INSPECTION TASKS AFTER WELDING (TABLE N5.4-3) A. WELDS CLEANED X B. SIZE LENGTH AND LOCATION OF WELDS X C. WELDS MEET VISUAL ACCEPTANCE CRITERIA, CRACK PROHIBITION, WELD/BASE-METAL FUSION, CRATER CROSS SECTION, WELD PROFILES, WELD SIZE, UNDERCUT, POROSITY X D. ARC STRIKES X E. K-AREA (WHEN WELDING OF DOUBLER PLATES, CONTINUITY PLATES OR STIFFENERS HAS BEEN, ERFORMED IN THE K-AREA, VISUALLY INSPECT THE WEB K-AREA FOR CRACKS WITHIN 3 IN. (75 MM) OF THE WELD). X F. WELD ACCESS HOLES IN ROLLED HEAVY SHAPES AND BUILT-UP HEAVY SHAPES (AFTER ROLLED HEAVY SHAPES AND BUILT-UP HEAVY SHAPES ARE WELDED, VISUALLY INSPECT THE WELD ACCESS HOLE FOR CRACKS) X G. BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED) X H. REPAIR ACTIVITIES X I. DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER X J. NO PROHIBITED WLEDS HAVE BEEN ADDED WITHOUT THE APPROVAL OF THE EOR X 4. INSPECTION TASKS PRIOR TO BOLTING (TABLE N5.6-1) A. MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENER MATERIALS X B. FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS X C. CORRECT FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE, BOLT LENGTH IF THREADS ARE TO BE EXCLUDED FROM SHEAR PLANE)X D. CORRECT BOLTING PROCEDURE SELECTED FOR JOINT DETAIL X E. CONNECTION ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACE CONDITION AND HOLE PREPARATION, IF SPECIFIED, MEET APPLICABLE REQUIREMENTS X F. PRE-INSTALLED VERIFICATION TESTING BY INSTALLATION PERSONNEL OBSERVED AND DOCUMENTED FOR FASTENER ASSEMBLIES AND METHODS USED X G. PROTECTED STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS AND OTHER FASTENER COMPONENTS X 5. INSPECTION TASKS DURING BOLTING (TABLE N5.6-2) A. FASTENER ASSEMBLIES PLACED IN ALL HOLES AND WASHERS AND NUTS ARE POSITIONED AS REQUIRED X B JOINT BROUGHT TO TH SNUG-TIGHT CONDITION PRIOR TO THE PRETENSIONING OPERATION X C FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROM ROTATING X D FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC SPECIFICATION, PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID POINT TOWARDS THE FREE EDGES X 6. INSPECTION TASKS AFTER BOLTING (TABLE N5.6-3) A. DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS X 7. INSPECTOR SHALL BE ON PREMISES FOR INSPECTION DURING THE PLACEMENT OF ANCHOR RODS AND OTHER EMBEDMENTS SUPPORTING STRUCTURAL STEEL. THE INSPECTOR SHALL INSPECT THE FABRICATED STEEL OR ERECTED STEEL FRAME, AS APPLICABLE, TO VERIFY COMPLIANCE WITH THE DETAILS SHOWN ON THE CONSTRUCTION DOCUMENTS (SECTION N5.7) X 1. THE OWNER OR THE OWNER'S AUTHORIZED AGENT, OTHER THAN THE CONTRACTOR, SHALL EMPLOY ONE OR MORE APPROVED AGENCIES TO PROVIDE SPECIAL INSPECTIONS AND TESTS DURING CONSTRUCTION ON THE TYPES OF WORK SPECIFIED PER IBC SECTION 1705 AND IDENTIFY THE APPROVED AGENCIES TO THE BUILDING OFFICIAL. SPECIAL INSPECTIONS ARE REQUIRED AS FOLLOWS: SPECIAL INSPECTION ITEMS: SPECIAL INSPECTION AND TESTS OF SOILS (IBC TABLE 1705.6) TYPE CO N T I N U O U S PE R I O D I C 1.VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY.X 2.VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL.X 3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS. X 4. DURING FILL PLACEMENT, VERIFY USE OF PROPER MATERIALS AND PROCEDURES IN ACCORDANCE WITH THE PROVISIONS OF THE APPROVED GEOTECHNICAL REPORT. VERIFY DENSITIES AND LIFT THICKNESS DURING PLACEMENT AND COMPACTION OF COMPACTED FILL. X 5.PRIOR TO PLACEMENT OF COMPACTED FILL, INSPECT SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY.X 2. QUALITY ASSURANCE PROGRAM: A. THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED TO BE CERTAIN IT CONFORMS WITH THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS. B. THE SPECIAL INSPRECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL, AND TO THE STRUCTURAL ENGINEER OF RECORD. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, ID UNCORRECTED, TO THE DESIGN AUTHORITY AND THE BUILDING OFFICIAL. S pe cial Inspe ctor ne e ds to b e ide ntifie d as pe r S e ction17 04 .2 .1 CONCRETE SLAB ON GRADE CONCRETE SLAB ON GRADE W/ EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME FINISH FLOOR = 100'-0" 4"#3 AT 18" O.C. 6 4 3 1 2 ABDE 5 C AABBCC 3.5 4.8 1.5 D.1 C.1 B.1 SC3 SC3 SC3 SC3 SC3SC3 SC3 SC3 SC3 SC2 SC4 SC2 F36 F72 F72 F36 F72 F72 F72 F72F72F72 F72 F72 F72 SC2 F36 SC2 F36 SC1SC1 SC1 SC1 SC2 F36 SC2 F36 SC2 SC2 SC21'-2" F48 F36 46'-10" 5"14'-0"12'-2"7'-4"13'-4" 5 1/4" 52 ' - 8 3 / 4 " 11 ' - 5 " 8 " 8 " 1 0 ' - 4 " 10 ' - 4 " 4" 1' - 0 " 3 ' - 1 0 " 1 4 ' - 1 3 / 4 " 7 1 / 4 " 2'-0" 2'-0" 8 1/2" 1' - 4 " 20 ' - 8 " 1' - 4 " 2'-0" 2'-8 1/2" 8" 14'-0"12'-2" 2'-5 1/4" 3'-4" 1'-6 3/4" 13'-4" 5 1/4" 11'-0"11'-0"11'-10" 46'-10" 3'-0 1/2" 14 ' - 4 " 14 ' - 4 " 14 ' - 4 " 9' - 8 3 / 4 " 4'-4" 7'-8" 7' - 0 " 4 ' - 0 " WF24A WF24A WF18 WF18 WF24A WF24A WF18 WF24 WF18 WF18 WF24A WF 2 4 A WF 1 8 WF 2 4 A WF 1 8 WF 1 8 WF 2 4 WF 1 8 WF 2 4 WF 2 4 F72 / W2 / W2 / W1 / W1 / W1 / W2 / W1 /W1 /W1 /W1 /W1 /W1 /W1 /W1WF24 55 5 6. 6.6. 6. 5 5 5 6. 6. 5 5 5 5 6. 6. 5 5 101 S3.0 ________________________102 S3.0 ________________________ 102 S3.0 ________________________ 101 S3.0 ________________________ 101 S3.0 ________________________ 101 S3.0 ________________________ 105 S3.0 ________________________ 106 S3.0 ________________________ 104 S3.0 ________________________ 106 S3.0 ________________________ 104 S3.0 ________________________ 104 S3.0 ________________________ 104 S3.0 ________________________ 103 S3.0 ________________________ 101 S3.0 ________________________ 104 S3.0 ________________________ 106 S3.0 ________________________ 102 S3.0 ________________________ A A A A A B 110 S3.0 ________________________ 2' - 3 " 107 S3.0 ________________________ TYP B AA 6. 6.6. 6.6. B B 111 S3.0 ________________________ 110 S3.0 ________________________ S3.0 109 TYP S3.0 109 TYP S3.1 114 S3.0 108 S3.1 113 T.O.F. = 97'-0" A 1 TYP 8 1 / 2 " 6 ' - 3 1 / 2 " 3 ' - 3 1 / 2 " 103 S3.0 ________________________ 4" S3.1 112 T.O.F.=99'-4" T.O.F.=99'-4" T.O.F.=99'-4" 7 1 / 4 " 12 ' - 1 " 11 ' - 0 " 10 ' - 8 " 4 ' - 1 0 " 1 4 ' - 1 3 / 4 " 5 1 / 4 " 3' - 6 3 / 4 " 8 1 / 2 " 2 3/4" N O TF O R C O N S T R U C T I O N P U R P O S E S PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : CO R N E R O F 2 N D E A S T A N D M O O D Y R D . RE X B U R G , I D A H O 8 3 4 4 0 NE W B U I L D I N G F O R : DBP 4/ 5 / 2 0 2 3 9 : 2 5 : 3 1 A M A u t o d e s k D o c s : / / 2 3 - 0 3 8 _ B e e h i v e F ed e r a l C r e d i t U n i o n R e x b u r g / I F 2 3 - 0 3 8 _ B e e h i v e F e d e r a l C r e d i t U n i o n R e x b u r g . r v t S2.0 23-038 BE E H I V E F C U -N O R T H R E X B U R G FO U N D A T I O N P L A N 02/23/2023 AV NORTH WALL (W) SCHEDULE TYPE MATERIAL THICKNESS VERTICAL REINFORCING HORIZONTAL REINFORCING REMARKS W1 CONCRETE 10" #4 AT 16" O.C. #4 AT 10" O.C. --- W2 CONCRETE 16" #4 AT 18" O.C. EACH FACE #4 AT 12" O.C. EA FACE --- FOOTING SCHEDULE MARK LENGTH WIDTH THICKNESS REINFORCING REMARKS F36 36" 36" 10" (4) #4 EACH WAY TOP & BOTTOM --- F48 48" 48" 10" (4) #5 EACH WAY TOP & BOTTOM --- F72 72" 72" 12" (8) #5 EACH WAY TOP & BOTTOM --- WF18 CONT 18" 10" (2) #4 CONT BOTTOM --- WF24 CONT 24" 10" (2) #4 CONT BOTTOM --- WF24A CONT 24" 10" (3) #4 CONT TOP & BOTTOM --- KEYNOTES 1 CONCRETE BOLLARDS PER ARCH FOUNDATION PLAN NOTES A. VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B. ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C. THE DEPTH OF FOOTING DIMENSION INDICATED IN THE G.S.N. IS A MINIMUM. FOUNDATION CONTRACTOR SHALL COORDINATE WITH THE SOILS REPORT AND OTHER TRADES TO INSURE THAT THESE MINIMUMS ARE SUFFICIENT FOR THE WORK. SEE TYPICAL DETAILS FOR ADDITIONAL REQUIREMENTS. D. W1, W2, ETC. - AS SHOWN ON PLAN INDICATES CONCRETE OR MASONRY WALLS. SEE WALL SCHEDULE FOR ADDITIONAL INFORMATION. E. WF18, WF24, ETC. - AS SHOWN ON PLAN INDICATES A CONTINUOUS WALL FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. F. F36, F48, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. . G. . , , - AS SHOWN ON PLAN INDICATES A SHEARWALL HOLDOWN. SEE HOLDOWN SCHEDULES AND DETAILS FOR ADDITIONAL INFORMATION. H. P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. I. SC1, SC2, ETC. - AS SHOWN ON PLAN INDICATES A STEEL COLUMN. SEE STEEL COLUMN SCHEDULE FOR ADDITIONAL INFORMATION. COLUMNS START AT THE LEVEL THEY ARE CALLED OUT ON. J. PROVIDE CONTINUOUS BEARING FOR ALL POSTS AND BUILT-UP STUDS TO THE FOUNDATION PER TYPICAL "SOLID BLOCKING BETWEEN FLOORS" DETAIL. K. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. L. VERIFY EXACT SIZE AND LOCATION OF DEPRESSED AND/OR RAISED SLABS WITH ARCHITECTURAL DRAWINGS. M. FOR SIDEWALK AND LANDING LOCATIONS, SEE ARCHITECTURAL DRAWINGS. N. TYPICAL TOP OF CONCRETE WALL=100'-0" O. TYPICAL TOP OF EXTERIOR FOOTING=97'-0" P. TYPICAL TOP OF INTERIOR FOOTING=99'-8", UNO HOLDOWN SCHEDULE MARK HOLDOWN SHEARWALL END POST UNO ON PLAN ALTERNATE HOLDOWN ANCHOR BOLT DIA. A SIMPSON HTT4 W/ (18) 0.162x2.5" NAILS (2) 2x STUDS N/A 5/8" B SIMPSON HDU8 (2) 2x STUDS N/A 7/8" SCALE: 1/4" = 1'-0" FOUNDATION PLAN 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. NOTES: SHEARWALL TYPE SCHEDULE MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 5 7/16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 6. 7/16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 4" O.C. 8d COMMON AT 12" O.C. CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 24" O.C. CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 32" O.C. WOOD: 16d STAGGERED AT 4" O.C. STEEL COLUMN (SC) SCHEDULE MARK SIZE BASE CONNECTION SC1 HSS4x4x1/4 PER DETAIL, SEE PLAN SC2 HSS5x5x1/4 3/4"x11"x11" PLATE W/ (4) 3/4" DIA ANCHOR BOLTS W/ 8" MIN EMBEDMENT, U.N.O. SC3 HSS6x6x1/4 PER DETAIL, SEE PLAN SC4 HSS6x6x5/8 3/4"x12"x12" PLATE W/ (4) 3/4" DIA ANCHOR BOLTS W/ 8" MIN EMBEDMENT, U.N.O. A B D amp proofing and wate r proofing to comply with IB C S e ction 1804 .4 . C ity O rdinance re q u ire s one horiz ontal b ar in top 6 " of wall. M (2) 2"C. EA. W/ 3#3/0 + 1#3GND GROUNDING ELECTRODE SYSTEM SEE DETAIL THIS SHEET UNDERGROUND SECONDARY CONDUIT AND TENCHING BY E.C. CONDUCTORS PROVIDED AND INSTALLED BY ROCKY MOUNTAIN POWER CO. UNDERGROUND PRIMARY TRENCHING AND CONDUIT BY E.C. CONDUCTORS BY ROCKY MOUNTAIN POWER CO. UTILITY XFMR PROVIDED & INSTALLED BY RMP FIBERGLASS PAD BOX PROVIDED BY RMP AND INSTALLED BY E.C. SELF-CONTAINED METER BASE 320A 240V, 1P, 3W PER RMP CO. REQUIREMENTS PANEL 'A' *18,491A PAD BOX PROVIDED BY RMP AND INSTALLED BY E.C. (5/E3.1) FAULT CURRENT CALULATIONS WERE BASED ON INFINITE BUS, WITH AN ESTIMATED 75 KVA TRANSFORMER WITH A 1.69%Z. *18,491A BLDG. STEEL WATER MAIN GROUND BAR AT MAIN TTB GRND RODS MIN OF (2) 10FT APART STAND-OFF GROUND BAR LOCATED IN ELEC. RM NEXT TO SERVICE EQUIP. GROUND BAR SHALL BE ERICO #B543A010 OR EQUAL. PROVIDE AND INSTALL ALL REQ'D LUGS & TERMINALS. MOUNT VERT. TO CONSERVE AS MUCH WALL SPACE AS POSSIBLE. MAIN SERVICE EQUIPMENT G N NEUTRAL TO GND BOND AT THIS POINT ONLY #1/0 Cu #4 C u CONCRETE ENCASED ELECTRODE 3/ 4 " C . , 1 # 6 C u #1 / 0 C u #1 / 0 C u #1 / 0 C u WATER MAIN #1 / 0 C u 13053 STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP OFESSIONALENGIN EE R 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com Engineering Inc. Consulting Engineers PROJECT #: PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : SAM TEP 03/24/23 3/ 2 3 / 2 0 2 3 1 1 : 3 0 : 2 0 A M \ \ P A Y N E F I L E S E R V E R \ M a i n F i l e S t or a g e \ 2 0 2 3 \ B e e h i v e F C U R e x b u r g - 2 3 2 2 \ 1 0 _ W o r k i n g D r aw i n g s \ B e e h i v e F C U R e x b u r g _ S A M _ P a y n e . r v t E3.0 19035 BE E H I V E F C U - N O R T H R E X B U R G CO R N E R O F 2 N D E A S T A N D M O O D Y R D . PO W E R R I S E R & S C H E D U L E S MARCH 2023 NE W B U I L D I N G F O R : RE X B U R G , I D A H O 8 3 4 4 0 2322 SCALE: NONE1POWER RISER DIAGRAM SCALE: NONE2BLDG GROUNDING ELECTRODE SYSTEM DETAIL LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION MOUNTING VOLTS LAMPS MFGR.CATALOG # APPROVED MFGR'S NOTES EXTERIOR FE1 AREA POLE LIGHT, SINGLE-HEAD, TYPE 4 DIST. W/ HOUSESIDE SHIELD POLE (SEE DETAIL) MULTI-TAP LED-7754LM-4000K LITHONIA HEAD: RSX2 LED-P1-40K-R4-MVOLT-SPA-HS-DDBXD; POLE: SSS-25-4C-DM19AS-DDBXD COOPER FE2 LED FLOODLIGHT, FULL VISOR, MEDIUM SPOT (RIGHT ANGLE ARM MOUNT TO POLE) POLE LIGHT 120-277 LED-7370LM-4000K LITHONIA DSXF2 LED-P1-40K-MSP-MVOLT-IS-DMG-FV-DDBXD COOPER FE3 ARCHITECTURAL SCONCE LIGHT WALL 120-277 LED-1200LM-4000K COOPER 303-W2-LEDB2-4000-UNV-T2-DIM10-SCBA-EDGE LITHONIA 3 FE4 EXTERIOR LED WALL PACK WALL 120-277 LED-3200LM-4000K LITHONIA WDGE2LED-P3-40K-80CRI-VW-MVOLT-DDBXD COOPER 3 FE4E EXTERIOR LED WALL PACK, EMERG. BATTERY PACK WALL 120-277 LED-3200LM-4000K LITHONIA WDGE2LED-P3-40K-80CRI-VW-MVOLT-E10WH-DDBXD COOPER 3 FE5 6" ROUND RECESSED LED CAN, 0-10V DIMMING RECESSED 120-277 LED-2000LM-4000K COOPER LD6A20-DE010-ERM6A-20-840-6LM1H LITHONIA INTERIOR F1 4FT LED STRIP SURFACE 120-277 LED-4000LM-4000K COOPER 4SLSTP2040DD-120V LITHONIA F2 6" ROUND RECESSED LED CAN, 0-10V DIMMING RECESSED 120-277 LED-1000LM-4000K COOPER LD6A10-DE010-ERM6A-10-840-6LM1H LITHONIA F2E 6" ROUND RECESSED LED CAN, 0-10V DIMMING, W/ EM BATTERY PACK RECESSED 120-277 LED-1000LM-4000K COOPER LD6A10-DE010-EM14-ERM6A-10-840-6LM1H LITHONIA F3 2X2 LAY-IN GRID TROFFER RECESSED 120-277 LED-3500LM-4000K COOPER DRI-WS-4-L40-UNV-22-T1-HCD-W6 NO EQUALS F3E 2X2 LAY-IN GRID TROFFER, W/ EMERG. BATTERY PACK RECESSED 120-277 LED-3500LM-4000K COOPER DRI-WS-4-L40-UNV-22-T1-HCD-EL14W-W6 NO EQUALS F4 2X4 LAY-IN GRID TROFFER RECESSED 120-277 LED-4000LM-4000K COOPER DRI-WS-2-L40-UNV-24-T1-HCD-W6 NO EQUALS 1 F5 4FT LED LINEAR DIRECT/INDIRECT PENDANT, 0-10V DIMMING, WIRELESS CONTROL W/ INTEGRAL SENSOR SUSPENDED 120-277 LED-1500LM/FT 4000K COOPER DSI-WS-60L-840-1-120-STD-SWPD1-DC-SCBA-AC120-ST-4FT NO EQUALS 3,4,6 F6 8FT LED LINEAR DIRECT/INDIRECT PENDANT, 0-10V DIMMING SUSPENDED 120-277 LED-1500LM/FT 4000K COOPER DSI-WS-60L-840-1-120-STD-SWPD1-DC-SCBA-AC120-ST-8FT NO EQUALS 3,4,6 F7E 16FT LED LINEAR DIRECT/INDIRECT PENDANT, 0-10V DIMMING, WIRELESS CONTROL W/ INTEGRAL SENSOR, EMERG. BATTERY PACK SUSPENDED 120-277 LED-1500LM/FT 4000K COOPER DSI-WS-60L-840-1-120-STD-SWPD1-EL14W/EPC-DC-SCBA-AC120-ST-16FT NO EQUALS 3,4,6 F8 24FT LED LINEAR DIRECT/INDIRECT PENDANT, 0-10V DIMMING, WIRELESS CONTROL W/ INTEGRAL SENSOR SUSPENDED 120-277 LED-1500LM/FT 4000K COOPER DSI-WS-60L-840-1-120-STD-SWPD1-DC-SCBA-AC120-ST-24FT NO EQUALS 3,4,6 F8E 24FT LED LINEAR DIRECT/INDIRECT PENDANT, 0-10V DIMMING, WIRELESS CONTROL W/ INTEGRAL SENSOR, EMERG. BATTERY PACK SUSPENDED 120-277 LED-1500LM/FT 4000K COOPER DSI-WS-60L-840-1-120-STD-SWPD1-EL14W/EPC-DC-SCBA-AC120-ST-24FT NO EQUALS 3,4,6 F9 ARCHITECTURAL MONO-POINT PENDANT SUSPENDED 120 LED LAMP SONNEMAN SON130709 NO EQUALS F10 BATHROOM VANITY LIGHT WALL ABOVE MIRROR 120-277 (2) LED LAMP LIGHTOLOGY SVY665690 NO EQUALS LIFE SAFETY FX1 EDGE LITE EXIT SIGN W/90 MIN. BATTERY, GREEN LED, SINGLE FACE/DOUBL FACE WALL OR CEILING 120-277 WITH FIXTURE MULE LTG PVT-U-B-G-S/R-SCBA LITHONIA 3 FX2 WALL MOUNTED EXTERIOR EMERGENCY EGRESS LIGHT, W/HEATER WALL ABOVE DOOR 120-277 WITH FIXTURE COOPER AEL2-46-SCBA LITHONIA 3 1. REFER TO DRAWINGS FOR FIXTURES REQUIRED TO HAVE 0-10V OR STEP-LEVEL DIMMING CONTROL. PROVIDE FIXTURE(S) WITH LED DRIVER(S) AND REQUIRED DIMMING/SWITCH-LEG CONDUCTORS BETWEEN SWITCH(ES) AND FIXTURE(S) TO PROVIDE CONTROL AS INDICATED ON DRAWINGS. 2. FIXTURE TO BE CONTINUOUS ROW MOUNTED, LENGTH AS INDICATED ON DRAWINGS. PROVIDE REQUIRED ACCESSORIES/CONNECTORS FOR CONTINUOUS ROW MOUNTING. 3. SCBA - STANDARD COLOR BY ARCHITECT/OWNER (COORDINATE COLOR WITH ARCHITECT/OWNER PRIOR TO ORDERING.) 4. FIELD ADJUST PENDANT LENGTH AS REQUIRED, VERIFY LENGTH WITH COUNTER AS DIRECTED BY ARCHITECT. 5. REFER TO ARCHITECTURAL ELEVATION DRAWINGS FOR PLACEMENT AND MOUNTING HEIGHT OF FIXTURES. 6. REFER TO THE GENERAL LIGHTING CONTROL NOTES FOR COMMISSIONING OF WIRELESS CONTROLLED FIXTURES. LIGHT FIXTURE SCHEDULE NOTES: 1. PROVIDE ADDITIONAL POWER PACKS; SENSOR SWITCH PP20 AS NEED FOR QTY OF OCCUPANCY SENSORS/SWITCHES. 2. DEVICE COLOR SHALL MATCH WIRING DEVICES; REFER TO SPECIFICATIONS. 3. REFER TO MANUFACTURER DOCUMENTATION FOR QTY AND SIZE OF CONDUCTORS BETWEEN LOW VOLTAGE SWITCH, SENSOR(S) AND POWER/RELAY PACKS. 4. PROVIDE SECONDARY RELAY PACK; SENSOR SWITCH SP20 AS NEEDED TO PROVIDE DUAL-LEVEL SWITCHING OF FIXTURES. 5. PROVIDE 0-10V DIMMING CONDUCTORS (GREY & VIOLET) BETWEEN SWITCH AND LIGHT FIXTURES FOR DIMMING CONTROL. 6. CUSTOM WALLSTATION ENGRAVINGS IS REQUIRED FOR WALLSTATION AND SHALL BE SPECIFIED/COORDINATED WITH OWNER AFTER PROGRAMMING OF SYSTEM. OCC. SENSOR/LTG CONTROLS SCHEDULE NOTES: • E.C. SHALL BE REPSONSIBLE FOR THE PROGRAMMING/COMMISSIONING OF THE LIGHTING CONTROL SYSTEMS (WIRED AND WIRELESS SYSTEMS) TO FUNCTION AS INDICATED OR AS DIRECTED BY OWNER AND SHALL INCLUDE ALL REQUIRED COST IN THE BASE BID. THE DAYLIGHTING SET-POINTS SHALL BE COORDINATED WITH THE OWNER FOR EACH AREA PRIOR TO FINAL PROGRAMMING OF THE DAYLIGHTING SENSOR(S). ALL PROGRAMMING/COMMISSIONING SHALL BE DONE BY A FACTORY CERTIFIED OR TRAINED PERSON. • LIGHTING IN SPACES WITH WIRELESS CONTROLS SHALL BE FIELD TUNED TO FOOTCANDLE LEVELS THAT ARE SATISFACTORY TO THE OWNER DURING PROGRAMMING AND COMMISSIONING OF THE LIGHTING SYSTEMS. GENERAL LIGHTING CONTROL NOTES: LIGHTING OCCUPANCY SENSOR AND CONTROL SCHEDULE TYPE MFGR. CATALOG #DESCRIPTION NOTES APPROVED EQUALS CEILING SENSORS CD2 SENSOR SWITCH CM PDT 9 R DUAL-TECHNOLOGY, SMALL MOTION 360 DEGREE COVERAGE, LOW VOLTAGE, W/ISOLATED RELAY 1 COOPER CD6 SENSOR SWITCH CMR PDT 9 DUAL-TECHNOLOGY, LINE VOLTAGE, SMALL MOTION 800W MAX LOAD COOPER WALL SENSORS WD1 SENSOR SWITCH WSX PDT-**- DUAL-TECHNOLOGY, 1-POLE, NEUTRAL REQUIRED 2 COOPER WDD SENSOR SWITCH WSX-PDT-D DUAL-TECHNOLOGY, 0-10V DIMMING 2,5 COOPER WALL SWITCHPODS SPD SENSOR SWITCH sPODM-**-D LOW VOLTAGE PUSH-BUTTON SWITCHPOD, 1-POLE W/DIMMING 2,3,4,5 COOPER WIRELESS CONTROLS W1R COOPER W1L-RL-G WAVELINX 1-BUTTON LARGE WALL STATION W/ RAISE/LOWER 2 LITHONIA WAC COOPER WAC- POE & WPOE-120 WAVELINX WIRELESS AREA CONTROLLER, PROVIDE 120V PoE INJECTOR S = SHUNT-TRIP BREAKER G = GFCI BREAKER R = RED HANDLED, LOCK-OUT TYPE A = ARC-FAULT BREAKER GP = GFEPD BREAKER LCP = CRKT TO BE ROUTED THROUGH LTG CONTROL PANEL BRK NOTES: Elec. Heating 4500 VA 100.00% 4500 VA Power 9482 VA 100.00% 9482 VA Receptacle 19100 VA 76.18% 14550 VA TOTAL EST. DEMAND AMPS:262 A Other 2000 VA 100.00% 2000 VA TOTAL CONN. AMPS.:279 A Motor 9453 VA 105.13% 9938 VA TOTAL EST. DEMAND:62976 VA Lighting 2712 VA 100.00% 2712 VA TOTAL CONN. LOAD:67034 VA HVAC 20280 VA 100.00% 20280 VA LOAD CLASSIFICATION CONNECTED... DEMAND FACTOR EST. DEMAND PANEL TOTALS PANEL SUMMARY TOTAL AMPS:274 A 285 A TOTAL LOAD:32.9 kVA 34.1 kVA 71 ---- -- -- 4152 0 -- -- -- --72 69 CU - 2 40 A 2 4152 0 2 20 A -- SURGE PROTECTION DEVICE 70 67 ---- -- -- 3468 2520 -- -- -- --68 65 CU - 1 40 A 2 3468 2520 2 30 A FC-1a/1b 66 63 F - 2 30 A 1 1920 0 1 20 A -- SPARE 64 61 F - 1 30 A 1 1920 0 1 20 A -- SPARE 62 59 ---- -- -- 2250 0 1 20 A -- SPARE 60 57 WATER HEATER 30 A 2 2250 0 1 20 A -- SPARE 58 55 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 56 53 Drive-Thru Blwr 20 A 1 1392 0 1 20 A -- SPARE 54 51 Drive-Thru Blwr 20 A 1 1392 0 1 20 A -- SPARE 52 49 Drive-Thru Blwr (FUTURE) 20 A 1 1392 0 1 20 A -- SPARE 50 47 Drive-Thru Blwr (FUTURE) 20 A 1 1392 1000 -- -- -- --48 45 Receptacle - Cash Recycler 20 A 1 180 1000 2 20 A ELECTRIC WALL HEATER 46 43 Receptacle 20 A 1 360 540 1 20 A Receptacle 44 41 Receptacle 20 A 1 1025 1080 1 20 A Receptacle 42 39 Coin Machine 20 A 1 540 900 1 20 A Receptacle 40 37 ADA Doors 20 A 1 1000 900 1 20 A Receptacle 38 35 Receptacle 20 A 1 900 900 1 20 A Receptacle 36 33 Receptacle 20 A 1 478 1200 1 30 A Drive-Thru ATM 34 31 Receptacle-Drive-thru Window 20 A 1 900 2000 1 20 A Open/Closed Signage 32 29 Receptacle -Drive-thru Window 20 A 1 1080 500 1 20 A Night Deposit Box 30 27 Receptacle -Drive-thru Window 20 A 1 900 540 1 20 A Receptacle 28 25 Receptacle - Copy Mach. 20 A 1 540 720 1 20 A Receptacle 26 23 Receptacle - Trans. Drawer 20 A 1 180 1220 1 20 A Receptacle 24 21 Lighting 20 A 1 271 1140 1 20 A Receptacle 22 19 Lighting 20 A 1 801 360 1 20 A TTB 20 17 Lighting 20 A 1 1043 360 1 20 A TTB 18 15 HEAT TRACE GP/LCP 20 A 1 500 1080 1 20 A Receptacle 16 13 HEAT TRACE GP/LCP 20 A 1 1000 900 1 20 A Receptacle 14 11 HEAT TRACE GP/LCP 20 A 1 1000 720 1 20 A Receptacle - Soffit 12 9 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 10 7 Bldg - Signage LCP 20 A 1 1000 0 1 20 A -- SPARE 8 5 Bldg - Signage LCP 20 A 1 500 0 1 20 A -- SPARE 6 3 Lighting - Bldg Exterior LCP 20 A 1 523 500 1 20 A Signage 4 1 Lighting - Site LCP 20 A 1 352 900 1 20 A Receptale - Site 2 CKT CIRCUIT DESCRIPTION NOTE AMPS P A B P AMPS NOTE CIRCUIT DESCRIPTION CKT PROVIDE PANEL WITH INTEGRAL OR EXTERNAL SURGE PROTECTION DEVICE NOTES: MFGR/MODEL:SQ. D/NQ SERIES DIMENSIONS:20"W x 5.8"D x *"H FEED:BOTTOM ENCLOSURE:NEMA 1 BUSSING:SEE SPEC'S MBR AMPS:400 A MOUNTING:SURFACE WIRES:3 PANEL AMPS:400 A FED FROM: PHASES:1 PANEL TYPE:MBR BEEHIVE FCU - NORTH REXBURG PANEL LOCATION: VOLTAGE:120/240 Single A.I.C. RATING:22k PROJECT NAME: PANEL: A PAYNE ENGINEERING 2 017 N EC re q u ire s minimu m # 6 G EC for grou nd rods. P le ase v e rify # 4 is de sire d. 2 017 N EC re q u ire s minimu m # 4 G EC . P le ase v e rify 1/0 is de sire d.