HomeMy WebLinkAboutDESCRIPTION OF REVISIONS - 22-00610 - U-Haul - New Commercial Bldg A Brett Gulash Hillside Architecture, PLLC 409 S 8th Str., Ste 201 Boise, ID 83702 775-722-1682 Project: 718081 U-Haul Moving & Storage of Rexburg 328 N 2nd E Rexburg, ID 83440 Revision 5 Narrative: Delta #: 4 Description: UHI Comments / City Resubmittal Date: 10.13.2022 Architectural Sheet# DESCRIPTION OF REVISION____________________ A1.1 Added additional notation to Knox Box NOTE “CONTRACTOR TO CONFIRM FINAL LOCATION WITH FIRE MARSHALL.” Structural, Mechanical, Electrical, and Plumbing Sheet# DESCRIPTION OF REVISION____________________ No Change Fire Protection Sheet# DESCRIPTION OF REVISION____________________ FP101 Added Remote FDC location to plan west near door 112 Civil Design Changes after Bid Set prior to City Approval 9/29/2022 Sheet C4 General Layout 1. Sidewalk against 2nd East pushed 7’ from curb and gutter per city requirements 2. Note added to remove existing curb cuts and replace with typical high back curb 3. Sidewalk added around Building A connecting all doors to the parking stalls. 4. Sidewalk connecting from Building A to the sidewalk against 2nd East providing Pedestrian access into the site per city request 5. Curb and gutter around rental vehicle parking against 2nd east to account for the lost stall from the added sidewalk. Curb radius changed near West access. 6. Retaining Wall Added south of the new sidewalk connecting building A to 2nd East. 7. Retaining Wall added near the property corner North of Building A Southwest of building A 8. Sidewalk against 3rd East shown and noted to retain and protect. 9. Entrance design adjustments amended to match City standard 10. Building B dimensions changed see Architectural Drawings for details 11. Building B Loading Dock Transitions changed per U-Haul Comments 12. ADA Stall added to the south side of Building B 13. Valley gutters between storage units rerouted to account for grade changes 14. Curb and gutter all changed to rolled curb 15. Retaining pond areas adjusted Sheet C5 Grading 1. Building Finish floor elevations Raised to meet city floodplain requirements 2. Site elevations raised in consequence to building elevation changes. 3. Swales and walls added 4. Truck dock grading changed at U-Haul Request. Sheet C6 Utilities 1. All Water meters joined into one 2” water meter at direction from the city service lines for building A, Building B and Landscape all tee off after meter. Service lines rerouted to meet building tie in points. 2. Underground storm system sizing and locations changed due to grading changes for flood plain considerations. 3. Sewer main size changed to an 8” main. Manhole depths adjusted to account for lower slope allowance. 4. Reroute of existing sewer service connection from Bank property to the south. 5. City fiber J boxes and conduits added to all road frontages. Sheet C7 1. Plan and profiles updated to reflect new grades Sheet C8 1. Pipe size on sewer main updated to 8” 2. Grades changed to reflect updated grading. 3. Manholes adjusted west to stay out from under parking stalls. Sheet C9 1. Foundation reveals and swale cross section details added 2. Rolled curb termination detail added. 10/12/2022 Sheet C3 1. Additional notes to clarify the removal of the existing entrance curb cuts Sheet C4 1. City Lights added at the entrance onto 4th north and 3rd east per city requirements. Use City of Rexburg standard detail sheet 9 for details. Key Note Added. Sheet C5 1. Dimension added detailing the distance from the FDC on Building B and Building A to the nearest Fire Hydrant both are less than 150’ away. Sheet C6 1. Dimension added detailing the distance from the FDC on Building B and Building A to the nearest Fire Hydrant both are less than 150’ away. 2. 4” Service Line adjusted to tie into 8” main bellow dead end manhole 3. City Lights added at the entrance onto 4th north and 3rd east per city requirements. Use City of Rexburg standard detail sheet 9 for details.