*PD–Product Data SD–Shop Drawings MD–Mix Design OM–O&M’s ASBLT–As Builts WAR–Warranty MU–Mock‐up REP–
Reports/Tests CERT–Certificates CLOSE–Closeouts INST–Installation/Instructions EM–Extra Materials CF – Conformance Forms
Submitted for Approval
Date: November 11, 2022 Subcontractor: Bryan Landon Construction Inc
Reviewer: Structural Edge Engineering
Attention: David Sansotta
Address: 5509 N Glenwood St
Garden City, ID 83714
RE: 01013 ‐ U‐Haul Rexburg, ID
Please review the following and return in accordance with the contract specifications:
Submittal Division Description Status
SD‐01.1 03 Bldg. A ‐ Foundation Rebar Shops ‐ Revised South Wall Detail For Approval
Vanessa Josephson
Vanessa Josephson
This review is only for general conformance with the
design concept of the project and general compliance
with the information given in the Contract Documents.
Corrections or comments made on the shop drawings
and submittals do not relieve the contractor from
compliance with the requirements of the plans and
specifications. Approval of a specific item shall not
include approval of an assembly of which the item is a
component. Contractor is responsible for: dimensions
and quantities to be confirmed and correlated at the
jobsite; information that pertains solely to the fabrication
processes or the means, methods, techniques,
sequences and procedures of construction;
coordination of the work with other drades; and for
performing all work in a safe and satisfactory manner.
Structural Edge Engineering
By: davids 11/14/2022Date:
Approved
Approved as Noted
Rejected
Revise and Resubmit
X
NOTE:
1. REINFORCING STEEL DETAILED IN
ACCORDANCE WITH CRSI & ACI315
STANDARDS.
2. REINFORCING STEEL IS A615,
GRADE 60, UNLESS OTHERWISE
NOTED.
3. REINFORCING STEEL PLACING
DRAWINGS MUST BE USED IN
CONJUNCTION WITH, & DO NOT
SUPERSEDE THE ENGINEERING
DRAWINGS.
4. DIMENSIONS SHOWN, IF ANY, ARE
FOR PLACING REINFORCING STEEL
ONLY. CONCRETE CONSTRUCTION
SUPPLY ASSUMES NO
RESPONSIBILITY FOR THE
DIMENSIONAL ACCURACY, DESIGN,
OR CONSEQUENCES OF DEFECTS
WHEN SUCH DIMENSIONS ARE USED
FOR CONSTRUCTION PURPOSES.
5. ANY ERRORS, INCONSISTENCIES, OR
OMISSIONS BETWEEN THE PLACING
DRAWINGS & ENGINEERING
DRAWINGS SHALL BE BROUGHT TO
CONCRETE CONSTRUCTION SUPPLY'S
ATTENTION PRIOR TO FABRICATION/
CONSTRUCTION.
ISSUED FOR
BRYAN LANDON CONST.
U-HAUL
REINF.
0270
JPS 9/20/2022
APPROVAL
R10