Loading...
HomeMy WebLinkAboutREVISED SOUTH WALL - 22-00610 - U-Haul - New Commercial Bldg AP.O. BOX 1464  IDAHO FALLS, IDAHO 83403 1405 FOOTE DRIVE  IDAHO FALLS, IDAHO 8402 PHONE (208) 523-2681  FAX (208) 524-4435 *PD–Product Data SD–Shop Drawings MD–Mix Design OM–O&M’s ASBLT–As Builts WAR–Warranty MU–Mock‐up REP– Reports/Tests CERT–Certificates CLOSE–Closeouts INST–Installation/Instructions EM–Extra Materials CF – Conformance Forms    Submitted for Approval    Date: November 11, 2022   Subcontractor: Bryan Landon Construction Inc   Reviewer: Structural Edge Engineering  Attention: David Sansotta  Address: 5509 N Glenwood St   Garden City, ID 83714    RE:  01013 ‐  U‐Haul Rexburg, ID    Please review the following and return in accordance with the contract specifications:  Submittal Division Description Status  SD‐01.1  03  Bldg. A ‐ Foundation Rebar Shops ‐ Revised South Wall Detail  For Approval      Vanessa Josephson   Vanessa Josephson                 This review is only for general conformance with the design concept of the project and general compliance with the information given in the Contract Documents. Corrections or comments made on the shop drawings and submittals do not relieve the contractor from compliance with the requirements of the plans and specifications. Approval of a specific item shall not include approval of an assembly of which the item is a component. Contractor is responsible for: dimensions and quantities to be confirmed and correlated at the jobsite; information that pertains solely to the fabrication processes or the means, methods, techniques, sequences and procedures of construction; coordination of the work with other drades; and for performing all work in a safe and satisfactory manner. Structural Edge Engineering By: davids 11/14/2022Date: Approved Approved as Noted Rejected Revise and Resubmit X NOTE: 1. REINFORCING STEEL DETAILED IN ACCORDANCE WITH CRSI & ACI315 STANDARDS. 2. REINFORCING STEEL IS A615, GRADE 60, UNLESS OTHERWISE NOTED. 3. REINFORCING STEEL PLACING DRAWINGS MUST BE USED IN CONJUNCTION WITH, & DO NOT SUPERSEDE THE ENGINEERING DRAWINGS. 4. DIMENSIONS SHOWN, IF ANY, ARE FOR PLACING REINFORCING STEEL ONLY. CONCRETE CONSTRUCTION SUPPLY ASSUMES NO RESPONSIBILITY FOR THE DIMENSIONAL ACCURACY, DESIGN, OR CONSEQUENCES OF DEFECTS WHEN SUCH DIMENSIONS ARE USED FOR CONSTRUCTION PURPOSES. 5. ANY ERRORS, INCONSISTENCIES, OR OMISSIONS BETWEEN THE PLACING DRAWINGS & ENGINEERING DRAWINGS SHALL BE BROUGHT TO CONCRETE CONSTRUCTION SUPPLY'S ATTENTION PRIOR TO FABRICATION/ CONSTRUCTION. ISSUED FOR BRYAN LANDON CONST. U-HAUL REINF. 0270 JPS 9/20/2022 APPROVAL R10 X