Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LOAD SHORT FORM - 23-00924 - 1110 Castle Pines Rd - New SFR
Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Dec-14 07:04:21 Rig ht-Su ite® U niv er sal 20 19 19 .0.15 RSU1 1362 Page 1 ...en\Documents\Wrightsoft HVAC\1660 Himalayan.rup Calc = MJ8 Front Door faces: N McrRaeJob:Load Short Form December 13, 2023Date:Entire House Dependable Heating & A...By: Copper Creek Homes Project Information Copper Creek HomesFor: Design Information InfiltrationClgHtg SimplifiedMethod90-7Outside db (°F) Semi-tightConstruction quality7570Inside db (°F) 0Fireplaces1577Design TD (°F) H-Daily range 5050Inside humidity (%) -2962Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make AMERISTAR Make AMERISTAR Trade AMERISTAR Trade AMERISTAR Model A951X060BU4S***Cond M4AC3030B1 AHRI ref 203926723 Coil TG32936D175B1605AP AHRI ref 201759593 Efficiency 96 AFUE Efficiency 10.0 EER, 13 SEER Heating input Btuh60000 Sensible cooling Btuh17500 Heating output Btuh45600 Latent cooling Btuh7500 Temperature rise °F44 Total cooling Btuh25000 Actual air flow cfm1110 Actual air flow cfm1110 Air flow factor cfm/Btuh0.045 Air flow factor cfm/Btuh0.088 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) family 736 3808 474 172 42 mech 156 0 0 0 0 bath 78 268 0 12 0 bed2 156 1141 330 52 29 bed3 221 1364 330 62 29 m bed 200 2208 1485 100 131 bath1 40 256 57 12 5 bed4 168 2142 944 97 83 m bath 126 945 620 43 55 bed5 120 1063 733 48 65 living 130 2252 948 102 84 great/kitchen 640 6406 5422 290 479 pantry 60 0 0 0 0 utiity 60 1546 755 70 67 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Dec-14 07:04:21 Rig ht-Su ite® U niv er sal 20 19 19 .0.15 RSU1 1362 Page 2 ...en\Documents\Wrightsoft HVAC\1660 Himalayan.rup Calc = MJ8 Front Door faces: N mud 60 0 0 0 0 bed1 143 1139 470 52 42 Entire House d 3094 24539 12566 1110 1110 Other equip loads 6826 1294 Equip. @ 0.95 RSM 13112 Latent cooling 0 TOTALS 3094 31365 13112 1110 1110 2023-Dec-14 07:04:21 Rig ht-Su ite® U niv er sal 20 19 19 .0.15 RSU1 1362 Page 1 ...en\Documents\Wrightsoft HVAC\1660 Himalayan.rup Calc = MJ8 Front Door faces: N McrRaeJob:Building Analysis December 13, 2023Date:Entire House Dependable Heating & A...By: Copper Creek Homes Project Information Copper Creek HomesFor: Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1577Design TD (°F)ft4744Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-29.461.7Moisture difference (gr/lb)CoolingHeating Infiltration:90-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) Semi-tightConstruction quality61-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Doors Ceilings Floors Infiltration Ventilation % of loadBtuhBtuh/ft²Component 28.589523.2Walls 19.4609423.1Glazing 3.9122530.0Doors 7.924701.5Ceilings 8.125451.61.6Floors 10.432531.9Infiltration 00Ducts 00Piping 00Humidification 21.86826Ventilation0Adjustments 100.031365Total Cooling Walls Glazing Doors Ceilings OtherInfiltration Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 6.48840.3Walls 49.7688326.1Glazing 2.12967.3Doors 9.713510.8Ceilings 0.3470.0Floors 2.33250.2Infiltration 00Ducts 9.31294Ventilation 20.12780Internal gains 00Blower 0Adjustments 100.013860Total Latent Cooling Load = 0 Btuh Overall U-va lue = 0.0 44 Btuh/ft²-°F Data entries checked. 2023-Dec-14 07:04:21 Rig ht-Su ite® U niv er sal 20 19 19 .0.15 RSU1 1362 Page 1 ...en\Documents\Wrightsoft HVAC\1660 Himalayan.rup Calc = MJ8 Front Door faces: N McrRaeJob:Component Constructions December 13, 2023Date:Entire House Dependable Heating & A...By: Copper Creek Homes Project Information Copper Creek HomesFor: Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1577Design TD (°F)ft4744Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-29.461.7Moisture difference (gr/lb)CoolingHeating Infiltration:90-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) Semi-tightConstruction quality61-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 15B19-0wc-8: Bg wall, heavy dry or light damp soil, 2"x4" wood int frm, concrete wall, r-19 cav ins, 8" thk, 1/2" gypsum board int fnsh 005692.7419.00.040208ne 0013193.0019.00.040440se 007393.0819.00.040240sw 0013193.0019.00.040440nw 0039472.9719.00.0401328all 51G: R22 Continuous 1960.6111093.4722.00.045320ne 200.611123.4722.00.04532e 1980.6111203.4722.00.045323se 200.611123.4722.00.04532s 1980.6111233.4722.00.045324sw 2520.6114283.4722.00.045412nw 8840.6150043.4722.00.0451444all Partitions (none) Windows Double Pane with low E .30: Double Pane with low E .30; NFRC rated (SHGC=0.30); 6.67 ft head ht 72322.673923.100.30032ne 45928.737023.100.30016se 36222.637023.100.30016nw 154324.1147823.100.30064all Double pane with low E: double pane .30 U Value; NFRC rated (SHGC=0.30); 6.67 ft head ht 9022.69223.100.3004ne 389428.7313723.100.300136se 135622.6138623.100.30060nw 534026.7461523.100.300200all Doors 11D0: Door, wd sc type 2967.25122530.000.39041nw Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-31 roof ins, r-50 ceil ins, 1/2" gypsum board int fnsh 13510.8424701.5450.00.0201604 Floors 2023-Dec-14 07:04:21 Rig ht-Su ite® U niv er sal 20 19 19 .0.15 RSU1 1362 Page 2 ...en\Documents\Wrightsoft HVAC\1660 Himalayan.rup Calc = MJ8 Front Door faces: N 19A-30cscp: Flr floor, frm flr, 6" thkns, carpet flr fnsh, r-30 cav ins, tight crwl ovr 470.422502.2030.00.034114 21A-32c: Bg floor, heavy dry or light damp soil, 8' depth, carpet flr fnsh 022951.5400.0201490 0 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Dec-14 07:04:21 Rig ht-Su ite® U niv er sal 20 19 19 .0.15 RSU1 1362 Page 1 ...en\Documents\Wrightsoft HVAC\1660 Himalayan.rup Calc = MJ8 Front Door faces: N McrRaeJob:Project Summary December 13, 2023Date:Entire House Dependable Heating & A...By: Copper Creek Homes Project Information Copper Creek HomesFor: Notes: Design Information Idaho Falls Rgnl, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-7 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F77 Design TD °F15Daily range H Relative humidity %50Moisture difference gr/lb-29 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh24539 Structure Btuh12566 Ducts Btuh0 Ducts Btuh0Central vent (96 cfm)6826 Btuh Central vent (96 cfm)Btuh1294 Outside air Outside airHumidificationBtuh0Blower Btuh0 Piping Btuh0Equipment load Btuh31365 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh13112 Method Latent Cooling Equipment Load SizingSimplified Construction quality Semi-tight0Fireplaces Structure Btuh796 Ducts Btuh0Central vent (96 cfm)Btuh-1609 CoolingHeating Outside air30943094Area (ft²)Equipment latent load Btuh0 1443614436Volume (ft³)Air changes/hour 0.100.19 Equipment Total Load (Sen+Lat)Btuh13112 Equiv. AVF (cfm)2446 Req. total capacity at 0.70 SHR ton1.6 Heating Equipment Summary Cooling Equipment Summary Make AMERISTAR Make AMERISTARTradeAMERISTARTradeAMERISTAR Model A951X060BU4S***Cond M4AC3030B1AHRI ref 203926723 Coil TG32936D175B1605AP AHRI ref 201759593Efficiency96 AFUE Efficiency 10.0 EER, 13 SEER Heating input Btuh60000 Sensible cooling Btuh17500Heating output Btuh45600 Latent cooling Btuh7500 Temperature rise °F44 Total cooling Btuh25000Actual air flow cfm1110 Actual air flow cfm1110 Air flow factor cfm/Btuh0.045 Air flow factor cfm/Btuh0.088Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Dec-14 07:04:21Right-Su ite® U niv er sal 20 19 19 .0.15 RSU1 1362 Page 1...en\Documents\Wrightsoft HVAC\1660 Himalayan.rup Calc = MJ8 Front Door faces: N McrRaeJob:Right-J® W or ksheet December 13, 2023Date:Entire House Dependable Heating & A/CBy:Copper Creek Homes 1 Room name Entire House family 2 Exposed wall 361.2 ft 80.0 ft 3 Room height 8.5 dft 8.0 heat/coolft 4 Room dimensions ft736.0x1.0 5 Room area 3094.0 f t²736.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nene 2.742.74 0.000.00 240 208 569 0 32 32 99 0 .GG Double Pane with low 0.300Double Pane with low 0.300 nene 23.1023.10 22.6022.60 32 0 739 723 0 0 0 0 .WW 51G51G 0.0450.045 nene 3.473.47 0.610.61 324 320 1109 196 0 0 0 0 .GG Double pane with low 0.300Double pane with low 0.300 nene 23.1023.10 22.6022.60 4 0 92 90 0 0 0 0 1 1 WW 51G51G 0.0450.045 ee 3.473.47 0.610.61 32 32 112 20 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 sese 3.003.00 0.000.00 456 440 1319 0 272 256 753 0 GG Double Pane with low 0.300Double Pane with low 0.300 sese 23.1023.10 28.6728.67 16 0 370 459 16 0 370 459 WW 51G51G 0.0450.045 sese 3.473.47 0.610.61 459 323 1120 198 0 0 0 0 GG Double pane with low 0.300Double pane with low 0.300 sese 23.1023.10 28.6728.67 136 0 3137 3894 0 0 0 0 WW 51G51G 0.0450.045 ss 3.473.47 0.610.61 32 32 112 20 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 swsw 3.083.08 0.000.00 240 240 739 0 160 160 493 0 WW 51G51G 0.0450.045 swsw 3.473.47 0.610.61 324 324 1123 198 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nwnw 3.003.00 0.000.00 456 440 1319 0 176 176 542 0 GG Double Pane with low 0.300Double Pane with low 0.300 nwnw 23.1023.10 22.6022.60 16 0 370 362 0 0 0 0 WW 51G51G 0.0450.045 nwnw 3.473.47 0.610.61 513 412 1428 252 0 0 0 0 GG Double pane with low 0.300Double pane with low 0.300 nwnw 23.1023.10 22.6022.60 60 0 1386 1356 0 0 0 0 DD 11D011D0 0.3900.390 nwnw 30.0330.03 7.257.25 41 41 1225 296 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.541.54 0.840.84 1604 1604 2470 1351 0 0 0 0 FF 19A-30cscp19A-30cscp 0.0340.034 --2.202.20 0.420.42 114 114 250 47 0 0 0 0 FF 21A-32c21A-32c 0.0200.020 --1.541.54 0.000.00 1490 1490 2295 0 736 736 1133 0 6 c) AED excursion 0 15 Envelope loss/gain 21286 9461 3389 474 12 a)Infiltration 3253 325 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 6 1380 0 0 Appliances/other 1400 0 Subtotal (lines 6 to 13)24539 12566 3389 474 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 419 0 14 Subtotal 24539 12566 3808 474 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 24539 12566 3808 474 Air required (cfm)Air required (cfm)1110 1110 172 42 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Dec-14 07:04:21Right-Su ite® U niv er sal 20 19 19 .0.15 RSU1 1362 Page 2...en\Documents\Wrightsoft HVAC\1660 Himalayan.rup Calc = MJ8 Front Door faces: N McrRaeJob:Right-J® W or ksheet December 13, 2023Date:Entire House Dependable Heating & A/CBy:Copper Creek Homes 1 Room name mech bath 2 Exposed wall 22.0 ft 6.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft13.0x12.0 ft13.0x6.0 5 Room area 156.0 f t²78.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nene 2.742.74 0.000.00 0 0 0 0 0 0 0 0 .GG Double Pane with low 0.300Double Pane with low 0.300 nene 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 .WW 51G51G 0.0450.045 nene 3.473.47 0.610.61 0 0 0 0 0 0 0 0 .GG Double pane with low 0.300Double pane with low 0.300 nene 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 1 1 WW 51G51G 0.0450.045 ee 3.473.47 0.610.61 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 sese 3.003.00 0.000.00 0 0 0 0 48 48 148 0 GG Double Pane with low 0.300Double Pane with low 0.300 sese 23.1023.10 28.6728.67 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 sese 3.473.47 0.610.61 0 0 0 0 0 0 0 0 GG Double pane with low 0.300Double pane with low 0.300 sese 23.1023.10 28.6728.67 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 ss 3.473.47 0.610.61 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 swsw 3.083.08 0.000.00 80 80 246 0 0 0 0 0 WW 51G51G 0.0450.045 swsw 3.473.47 0.610.61 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nwnw 3.003.00 0.000.00 96 96 296 0 0 0 0 0 GG Double Pane with low 0.300Double Pane with low 0.300 nwnw 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 nwnw 3.473.47 0.610.61 0 0 0 0 0 0 0 0 GG Double pane with low 0.300Double pane with low 0.300 nwnw 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nwnw 30.0330.03 7.257.25 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.541.54 0.840.84 0 0 0 0 0 0 0 0 FF 19A-30cscp19A-30cscp 0.0340.034 --2.202.20 0.420.42 0 0 0 0 0 0 0 0 FF 21A-32c21A-32c 0.0200.020 --1.541.54 0.000.00 156 156 240 0 78 78 120 0 6 c) AED excursion 0 0 Envelope loss/gain 782 0 268 0 12 a)Infiltration 0 0 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)782 0 268 0 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -782 0 0 0 14 Subtotal 0 0 268 0 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 268 0 Air required (cfm)Air required (cfm)0 0 12 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Dec-14 07:04:21Right-Su ite® U niv er sal 20 19 19 .0.15 RSU1 1362 Page 3...en\Documents\Wrightsoft HVAC\1660 Himalayan.rup Calc = MJ8 Front Door faces: N McrRaeJob:Right-J® W or ksheet December 13, 2023Date:Entire House Dependable Heating & A/CBy:Copper Creek Homes 1 Room name bed2 bed3 2 Exposed wall 25.0 ft 30.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft13.0x12.0 ft13.0x17.0 5 Room area 156.0 f t²221.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nene 2.742.74 0.000.00 104 88 235 0 104 88 235 0 .GG Double Pane with low 0.300Double Pane with low 0.300 nene 23.1023.10 22.6022.60 16 0 370 362 16 0 370 362 .WW 51G51G 0.0450.045 nene 3.473.47 0.610.61 0 0 0 0 0 0 0 0 .GG Double pane with low 0.300Double pane with low 0.300 nene 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 1 1 WW 51G51G 0.0450.045 ee 3.473.47 0.610.61 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 sese 3.003.00 0.000.00 0 0 0 0 136 136 419 0 GG Double Pane with low 0.300Double Pane with low 0.300 sese 23.1023.10 28.6728.67 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 sese 3.473.47 0.610.61 0 0 0 0 0 0 0 0 GG Double pane with low 0.300Double pane with low 0.300 sese 23.1023.10 28.6728.67 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 ss 3.473.47 0.610.61 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 swsw 3.083.08 0.000.00 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 swsw 3.473.47 0.610.61 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nwnw 3.003.00 0.000.00 96 96 296 0 0 0 0 0 GG Double Pane with low 0.300Double Pane with low 0.300 nwnw 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 nwnw 3.473.47 0.610.61 0 0 0 0 0 0 0 0 GG Double pane with low 0.300Double pane with low 0.300 nwnw 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nwnw 30.0330.03 7.257.25 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.541.54 0.840.84 0 0 0 0 0 0 0 0 FF 19A-30cscp19A-30cscp 0.0340.034 --2.202.20 0.420.42 0 0 0 0 0 0 0 0 FF 21A-32c21A-32c 0.0200.020 --1.541.54 0.000.00 156 156 240 0 221 221 340 0 6 c) AED excursion -32 -32 Envelope loss/gain 1141 330 1364 330 12 a)Infiltration 0 0 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1141 330 1364 330 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1141 330 1364 330 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1141 330 1364 330 Air required (cfm)Air required (cfm)52 29 62 29 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Dec-14 07:04:21Right-Su ite® U niv er sal 20 19 19 .0.15 RSU1 1362 Page 4...en\Documents\Wrightsoft HVAC\1660 Himalayan.rup Calc = MJ8 Front Door faces: N McrRaeJob:Right-J® W or ksheet December 13, 2023Date:Entire House Dependable Heating & A/CBy:Copper Creek Homes 1 Room name m bed bath1 2 Exposed wall 28.2 ft 4.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft200.0x1.0 ft4.0x10.0 5 Room area 200.0 f t²40.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nene 2.742.74 0.000.00 0 0 0 0 0 0 0 0 .GG Double Pane with low 0.300Double Pane with low 0.300 nene 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 .WW 51G51G 0.0450.045 nene 3.473.47 0.610.61 126 126 437 77 36 36 125 22 .GG Double pane with low 0.300Double pane with low 0.300 nene 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 1 1 WW 51G51G 0.0450.045 ee 3.473.47 0.610.61 32 32 112 20 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 sese 3.003.00 0.000.00 0 0 0 0 0 0 0 0 GG Double Pane with low 0.300Double Pane with low 0.300 sese 23.1023.10 28.6728.67 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 sese 3.473.47 0.610.61 63 38 132 23 0 0 0 0 GG Double pane with low 0.300Double pane with low 0.300 sese 23.1023.10 28.6728.67 25 0 578 717 0 0 0 0 WW 51G51G 0.0450.045 ss 3.473.47 0.610.61 32 32 112 20 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 swsw 3.083.08 0.000.00 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 swsw 3.473.47 0.610.61 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nwnw 3.003.00 0.000.00 0 0 0 0 0 0 0 0 GG Double Pane with low 0.300Double Pane with low 0.300 nwnw 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 nwnw 3.473.47 0.610.61 0 0 0 0 0 0 0 0 GG Double pane with low 0.300Double pane with low 0.300 nwnw 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nwnw 30.0330.03 7.257.25 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.541.54 0.840.84 200 200 308 168 40 40 62 34 FF 19A-30cscp19A-30cscp 0.0340.034 --2.202.20 0.420.42 18 18 40 7 0 0 0 0 FF 21A-32c21A-32c 0.0200.020 --1.541.54 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -57 -6 Envelope loss/gain 1718 976 186 50 12 a)Infiltration 490 49 69 7 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 2 460 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2208 1485 256 57 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 2208 1485 256 57 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2208 1485 256 57 Air required (cfm)Air required (cfm)100 131 12 5 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Dec-14 07:04:21Right-Su ite® U niv er sal 20 19 19 .0.15 RSU1 1362 Page 5...en\Documents\Wrightsoft HVAC\1660 Himalayan.rup Calc = MJ8 Front Door faces: N McrRaeJob:Right-J® W or ksheet December 13, 2023Date:Entire House Dependable Heating & A/CBy:Copper Creek Homes 1 Room name bed4 m bath 2 Exposed wall 28.0 ft 9.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft14.0x12.0 ft14.0x9.0 5 Room area 168.0 f t²126.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nene 2.742.74 0.000.00 0 0 0 0 0 0 0 0 .GG Double Pane with low 0.300Double Pane with low 0.300 nene 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 .WW 51G51G 0.0450.045 nene 3.473.47 0.610.61 126 122 423 75 0 0 0 0 .GG Double pane with low 0.300Double pane with low 0.300 nene 23.1023.10 22.6022.60 4 0 92 90 0 0 0 0 1 1 WW 51G51G 0.0450.045 ee 3.473.47 0.610.61 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 sese 3.003.00 0.000.00 0 0 0 0 0 0 0 0 GG Double Pane with low 0.300Double Pane with low 0.300 sese 23.1023.10 28.6728.67 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 sese 3.473.47 0.610.61 0 0 0 0 81 65 225 40 GG Double pane with low 0.300Double pane with low 0.300 sese 23.1023.10 28.6728.67 0 0 0 0 16 0 370 459 WW 51G51G 0.0450.045 ss 3.473.47 0.610.61 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 swsw 3.083.08 0.000.00 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 swsw 3.473.47 0.610.61 18 18 62 11 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nwnw 3.003.00 0.000.00 0 0 0 0 0 0 0 0 GG Double Pane with low 0.300Double Pane with low 0.300 nwnw 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 nwnw 3.473.47 0.610.61 108 88 305 54 0 0 0 0 GG Double pane with low 0.300Double pane with low 0.300 nwnw 23.1023.10 22.6022.60 20 0 462 452 0 0 0 0 DD 11D011D0 0.3900.390 nwnw 30.0330.03 7.257.25 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.541.54 0.840.84 168 168 259 141 126 126 194 106 FF 19A-30cscp19A-30cscp 0.0340.034 --2.202.20 0.420.42 24 24 53 10 0 0 0 0 FF 21A-32c21A-32c 0.0200.020 --1.541.54 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 62 -1 Envelope loss/gain 1656 896 789 604 12 a)Infiltration 486 49 156 16 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2142 944 945 620 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 2142 944 945 620 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2142 944 945 620 Air required (cfm)Air required (cfm)97 83 43 55 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Dec-14 07:04:21Right-Su ite® U niv er sal 20 19 19 .0.15 RSU1 1362 Page 6...en\Documents\Wrightsoft HVAC\1660 Himalayan.rup Calc = MJ8 Front Door faces: N McrRaeJob:Right-J® W or ksheet December 13, 2023Date:Entire House Dependable Heating & A/CBy:Copper Creek Homes 1 Room name bed5 living 2 Exposed wall 10.0 ft 23.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft12.0x10.0 ft10.0x13.0 5 Room area 120.0 f t²130.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nene 2.742.74 0.000.00 0 0 0 0 0 0 0 0 .GG Double Pane with low 0.300Double Pane with low 0.300 nene 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 .WW 51G51G 0.0450.045 nene 3.473.47 0.610.61 0 0 0 0 0 0 0 0 .GG Double pane with low 0.300Double pane with low 0.300 nene 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 1 1 WW 51G51G 0.0450.045 ee 3.473.47 0.610.61 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 sese 3.003.00 0.000.00 0 0 0 0 0 0 0 0 GG Double Pane with low 0.300Double Pane with low 0.300 sese 23.1023.10 28.6728.67 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 sese 3.473.47 0.610.61 0 0 0 0 0 0 0 0 GG Double pane with low 0.300Double pane with low 0.300 sese 23.1023.10 28.6728.67 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 ss 3.473.47 0.610.61 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 swsw 3.083.08 0.000.00 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 swsw 3.473.47 0.610.61 0 0 0 0 90 90 312 55 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nwnw 3.003.00 0.000.00 0 0 0 0 0 0 0 0 GG Double Pane with low 0.300Double Pane with low 0.300 nwnw 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 nwnw 3.473.47 0.610.61 90 70 243 43 117 77 265 47 GG Double pane with low 0.300Double pane with low 0.300 nwnw 23.1023.10 22.6022.60 20 0 462 452 20 0 462 452 DD 11D011D0 0.3900.390 nwnw 30.0330.03 7.257.25 0 0 0 0 20 20 613 148 CC 16B-50ad16B-50ad 0.0200.020 --1.541.54 0.840.84 120 120 185 101 130 130 200 109 FF 19A-30cscp19A-30cscp 0.0340.034 --2.202.20 0.420.42 0 0 0 0 0 0 0 0 FF 21A-32c21A-32c 0.0200.020 --1.541.54 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 120 96 Envelope loss/gain 889 715 1852 908 12 a)Infiltration 174 17 400 40 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1063 733 2252 948 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1063 733 2252 948 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1063 733 2252 948 Air required (cfm)Air required (cfm)48 65 102 84 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Dec-14 07:04:21Right-Su ite® U niv er sal 20 19 19 .0.15 RSU1 1362 Page 7...en\Documents\Wrightsoft HVAC\1660 Himalayan.rup Calc = MJ8 Front Door faces: N McrRaeJob:Right-J® W or ksheet December 13, 2023Date:Entire House Dependable Heating & A/CBy:Copper Creek Homes 1 Room name great/kitchen pantry 2 Exposed wall 53.0 ft 16.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft640.0x1.0 ft10.0x6.0 5 Room area 640.0 f t²60.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nene 2.742.74 0.000.00 0 0 0 0 0 0 0 0 .GG Double Pane with low 0.300Double Pane with low 0.300 nene 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 .WW 51G51G 0.0450.045 nene 3.473.47 0.610.61 0 0 0 0 0 0 0 0 .GG Double pane with low 0.300Double pane with low 0.300 nene 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 1 1 WW 51G51G 0.0450.045 ee 3.473.47 0.610.61 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 sese 3.003.00 0.000.00 0 0 0 0 0 0 0 0 GG Double Pane with low 0.300Double Pane with low 0.300 sese 23.1023.10 28.6728.67 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 sese 3.473.47 0.610.61 315 220 763 135 0 0 0 0 GG Double pane with low 0.300Double pane with low 0.300 sese 23.1023.10 28.6728.67 95 0 2190 2718 0 0 0 0 WW 51G51G 0.0450.045 ss 3.473.47 0.610.61 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 swsw 3.083.08 0.000.00 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 swsw 3.473.47 0.610.61 126 126 437 77 90 90 312 55 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nwnw 3.003.00 0.000.00 0 0 0 0 0 0 0 0 GG Double Pane with low 0.300Double Pane with low 0.300 nwnw 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 nwnw 3.473.47 0.610.61 36 36 125 22 54 54 187 33 GG Double pane with low 0.300Double pane with low 0.300 nwnw 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nwnw 30.0330.03 7.257.25 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.541.54 0.840.84 640 640 986 539 60 60 92 51 FF 19A-30cscp19A-30cscp 0.0340.034 --2.202.20 0.420.42 0 0 0 0 24 24 53 10 FF 21A-32c21A-32c 0.0200.020 --1.541.54 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -172 -17 Envelope loss/gain 4500 3319 644 131 12 a)Infiltration 921 92 278 28 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 4 920 0 0 Appliances/other 900 0 Subtotal (lines 6 to 13)5421 5231 922 159 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 985 192 -922 -159 14 Subtotal 6406 5422 0 0 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 6406 5422 0 0 Air required (cfm)Air required (cfm)290 479 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Dec-14 07:04:21Right-Su ite® U niv er sal 20 19 19 .0.15 RSU1 1362 Page 8...en\Documents\Wrightsoft HVAC\1660 Himalayan.rup Calc = MJ8 Front Door faces: N McrRaeJob:Right-J® W or ksheet December 13, 2023Date:Entire House Dependable Heating & A/CBy:Copper Creek Homes 1 Room name utiity mud 2 Exposed wall 6.0 ft 10.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft10.0x6.0 ft10.0x6.0 5 Room area 60.0 f t²60.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nene 2.742.74 0.000.00 0 0 0 0 0 0 0 0 .GG Double Pane with low 0.300Double Pane with low 0.300 nene 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 .WW 51G51G 0.0450.045 nene 3.473.47 0.610.61 0 0 0 0 36 36 125 22 .GG Double pane with low 0.300Double pane with low 0.300 nene 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 1 1 WW 51G51G 0.0450.045 ee 3.473.47 0.610.61 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 sese 3.003.00 0.000.00 0 0 0 0 0 0 0 0 GG Double Pane with low 0.300Double Pane with low 0.300 sese 23.1023.10 28.6728.67 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 sese 3.473.47 0.610.61 0 0 0 0 0 0 0 0 GG Double pane with low 0.300Double pane with low 0.300 sese 23.1023.10 28.6728.67 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 ss 3.473.47 0.610.61 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 swsw 3.083.08 0.000.00 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 swsw 3.473.47 0.610.61 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nwnw 3.003.00 0.000.00 0 0 0 0 0 0 0 0 GG Double Pane with low 0.300Double Pane with low 0.300 nwnw 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 WW 51G51G 0.0450.045 nwnw 3.473.47 0.610.61 54 54 187 33 54 34 116 21 GG Double pane with low 0.300Double pane with low 0.300 nwnw 23.1023.10 22.6022.60 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nwnw 30.0330.03 7.257.25 0 0 0 0 20 20 613 148 CC 16B-50ad16B-50ad 0.0200.020 --1.541.54 0.840.84 60 60 92 51 60 60 92 51 FF 19A-30cscp19A-30cscp 0.0340.034 --2.202.20 0.420.42 24 24 53 10 24 24 53 10 FF 21A-32c21A-32c 0.0200.020 --1.541.54 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -59 -26 Envelope loss/gain 332 35 999 225 12 a)Infiltration 104 10 174 17 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13)436 545 1173 242 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 1109 210 -1173 -242 14 Subtotal 1546 755 0 0 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1546 755 0 0 Air required (cfm)Air required (cfm)70 67 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Dec-14 07:04:21Right-Su ite® U niv er sal 20 19 19 .0.15 RSU1 1362 Page 9...en\Documents\Wrightsoft HVAC\1660 Himalayan.rup Calc = MJ8 Front Door faces: N McrRaeJob:Right-J® W or ksheet December 13, 2023Date:Entire House Dependable Heating & A/CBy:Copper Creek Homes 1 Room name bed1 2 Exposed wall 11.0 ft 3 Room height 8.0 heat/coolft 4 Room dimensions ft13.0x11.0 5 Room area 143.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area Load number (Bt uh/f t²-°F)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-0wc-8 0.069 ne 2.74 0.00 0 0 0 0 .G Double Pane with low 0.300 ne 23.10 22.60 0 0 0 0 .W 51G 0.045 ne 3.47 0.61 0 0 0 0 .G Double pane with low 0.300 ne 23.10 22.60 0 0 0 0 1 1 W 51G 0.045 e 3.47 0.61 0 0 0 0 W 15B19-0wc-8 0.069 se 3.00 0.00 0 0 0 0 G Double Pane with low 0.300 se 23.10 28.67 0 0 0 0 W 51G 0.045 se 3.47 0.61 0 0 0 0 G Double pane with low 0.300 se 23.10 28.67 0 0 0 0 W 51G 0.045 s 3.47 0.61 0 0 0 0 W 15B19-0wc-8 0.069 sw 3.08 0.00 0 0 0 0 W 51G 0.045 sw 3.47 0.61 0 0 0 0 W 15B19-0wc-8 0.069 nw 3.00 0.00 88 72 186 0 G Double Pane with low 0.300 nw 23.10 22.60 16 0 370 362 W 51G 0.045 nw 3.47 0.61 0 0 0 0 G Double pane with low 0.300 nw 23.10 22.60 0 0 0 0 D 11D0 0.390 nw 30.03 7.25 0 0 0 0 C 16B-50ad 0.020 -1.54 0.84 0 0 0 0 F 19A-30cscp 0.034 -2.20 0.42 0 0 0 0 F 21A-32c 0.020 -1.54 0.00 143 143 220 0 6 c) AED excursion 108 Envelope loss/gain 776 470 12 a)Infiltration 0 0 b)Room ventilation 0 0 13 Internal gains:Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13)776 470 Less external load 0 0 Less transfer 0 0 Redistribution 363 0 14 Subtotal 1139 470 15 Duct loads -0%0%0 0 Total room load 1139 470 Air required (cfm)52 42 Job #: McrRae Performed by Dependable Heating & A/C for: Copper Creek Homes Copper Creek Homes Scale: 1 : 95 Page 1 Ri g h t-Su i te® Uni versal 2019 19.0.15 RSU11362 2023-Dec-14 07:04:45 ...ightsoft HVAC\1660 Himalayan.rup N Level 2 m bed bath1 bed4 m bath bed5 living great/kitchen pantryutiitymud 70 cfm 65 cfm 120 cfm 14 x 6 14 x 6 14 x 6 14 x 6 14 x 6 120 cfm 14 x 6 120 cfm 120 cfm 102 cfm 131 cfm 12 cfm 55 cfm 97 cfm Job #: McrRae Performed by Dependable Heating & A/C for: Copper Creek Homes Copper Creek Homes Scale: 1 : 95 Page 2 Ri g h t-Su i te® Uni versal 2019 19.0.15 RSU11362 2023-Dec-14 07:04:45 ...ightsoft HVAC\1660 Himalayan.rup N Level 1 family mech bath bed1bed2 bed3 6 " 57 cfm 52 cfm 57 cfm 14 x 6 57 cfm 14 x 6 14 x 6 14 x 6 14 x 6 1110 cfm 6 " 6 " 6 " 6 "6 " 6 " 6 "6 "6 " 24 x 8 6 " 20 x 10 12 cfm 6 " 62 cfm 52 cfm 6 " 6 " 6 " 6 " 6 " 6 "12 x 8 14 x 8 fresh air Bold/italic values have been manually overridden 2023-Dec-14 07:04:23 Rig ht-Su ite® U niv er sal 20 19 19 .0.15 RSU1 1362 Page 1 ...en\Documents\Wrightsoft HVAC\1660 Himalayan.rup Calc = MJ8 Front Door faces: N McrRaeJob:Duct System Summary December 13, 2023Date:Entire House Dependable Heating & A...By: Copper Creek Homes Project Information Copper Creek HomesFor: CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0.34in H2O0.34 Available static pressure in H2O0.36in H2O0.36 Supply / return available pressure 0.297 / 0.063 in H2O in H2O0.297 / 0.063 Lowest friction rate in/100ft0.085in/100ft0.085 Actual air flow cfm1110cfm1110 Total effective length (TEL)ft426 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st2270.029.0ShMt0x06.00.099012268hbath-A st2320.031.0ShMt0x06.00.085512256hbath1-A st2270.07.0ShMt0x06.00.10742521139hbed1 st2255.025.0ShMt0x06.00.10629521141hbed2-A st2255.039.0ShMt0x06.00.10129621364hbed3-A st2245.020.0ShMt0x06.00.11283972142hbed4-A st2260.08.0ShMt0x06.00.1116548733cbed5 st3290.032.0ShMt0x06.00.09214571269hfamily st3265.051.0ShMt0x06.00.09414571269hfamily-A st3280.041.0ShMt0x06.00.09214571269hfamily-B st3290.039.0ShMt0x06.00.090120721356cgreat/kitchen st3190.056.0ShMt0x06.00.121120721356cgreat/kitchen-A st3290.030.0ShMt0x06.00.093120721356cgreat/kitchen-B st3275.048.0ShMt0x06.00.092120721356cgreat/kitchen-C 95.04.1ShMt0x06.00.299841022252hliving-A st2270.022.0ShMt0x06.00.1025543620cm bath-A st2245.045.0ShMt0x06.00.1021311001485cm bed-A st3255.046.0ShMt0x06.00.09967701546hutiity 2023-Dec-14 07:04:23 Rig ht-Su ite® U niv er sal 20 19 19 .0.15 RSU1 1362 Page 2 ...en\Documents\Wrightsoft HVAC\1660 Himalayan.rup Calc = MJ8 Front Door faces: N Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st3 Peak AVF 532 588 0.090 755 11.5 14x8 ShtMetl st1 st1 Peak AVF 1008 1026 0.085 770 14.4 24x8 ShtMetl st2 Peak AVF 476 439 0.085 714 10.8 12x8 ShtMetl st1 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb1 0x 11100 1110 75.0 0.085 799 14.8 x10 20 ShMt