HomeMy WebLinkAboutDURASTAR UNIT - 20-00414 - 425 Harvard Ave - Blake Willis - Duplex Bldg 4PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR REFERENCE SUBMITTED BY PRODUCT FEATURES • Variable speed inverter compressor • Quiet operation • Low ambient heating down to -13 OF • Low ambient cooling down to 5 OF • Included base pan heater • Auto restart • Anti -corrosive coil coating • Port adaptors included 18,000 BTU/H MULTI -ZONE HEAT PUMP SYSTEM SUBMITTAL COVER SHEET DATE Multi -Zone Outdoor Unit (ODU): DPA2U18M1B Now CAPACITIES DUCTLESS MIXED DUCTED Cooling (BTU/hr) Rated' 18000 18000 18000 at 5 IF3 16100 16320 16540 Minimum 4950 4400 3850 Maximum 23000 22700 22400 Heating (BTU/hr) Patedz 19000 19000 19000 at 5 IF 11280 12290 13300 Minimum 4900 4975 5050 Maximum 23000 23700 24400 [Nominal IDU Capacity' (Min/Max) 12000/24000 Specifications are subject to change without notice. 0 2022 Ferguson Enterprises LLC www.durastar.com SYSTEM DATA Refrigerant Type P-410A Refrigerant Charge (oz.) 65.26 Design Pressure (PSIG) 550/340 Outdoor Coil Coating Golden Fin Coating EFFICIENCY DATA DUCTLESS MIXED DUCTED SEEP2 21.00 20.00 19.00 EEP2 12.50 12.25 12.00 HSPF2 10.20 10.00 9.80 SEEP 21.50 20.25 19.00 EEP 12.50 12.25 12.00 HSPF 10.60 10.70 10.80 COP at 47 IF 3.70 3.70 3.80 COP at 5 °F 1.85 1.94 2.03 u� LISTED V Form No. V1.0_10.22 18,000 BTU/H MULTI -ZONE HEAT PUMP SYSTEM SPECIFICATIONS - DRA2U18M1B LINE SET REQUIREMENTS Connection Type Flare Liquid 2 x 01/4" (06.35mm) Gas 2 x 03/8" (09.52mm) Refrigeration Adaptors Included 2 x 3/8"--1/2" Minimum Indoor Units Connected 2 Pre -Charge Length 49' Maximum Length (combined IDUs) 131' Maximum Length (per IDU) 82' Minimum Length (per IDU) 10, Max. Height Differential between IDU and ODU 49' Additional Refrigerant for 01/4" Liquid Pipe (oz./ft) 0.161 ELECTRICAL DATA DUCTLESS DUCTED Voltage/Phase/Frequency 208-230V, 1 Phase, 60 Hz Voltage Range 187-253V Recommended Breaker (Amps) 25 Minimum Circuit Ampacity (Amps) 18 Communication Wire Size 14*4 AWG Stranded Rated Current - Cooling (Amps)' 6.4 6.7 Rated Current - Heating (Amps)' 6.7 6.5 Measured at 95 OF. ' Measured at 47 OF. ' Sensible Capacity: Indoor 80 OF DB, 67 °F WB // Outdoor 5 OF DB, 4 °F WB 4 Maximum Capacity: Indoor 70 OF DB, 67 OF WB // Outdoor 5 OF DB, 4 OF WB 5 If the total indoor unit load exceeds the nominal capacity of the outdoor unit, the practical output capacity of each indoor unit will be correspondingly reduced. This situation is very evident during heating mode. OUTDOOR UNIT DATA Unit Dimensions Width 351/16" Depth 13 7/16" Height 261/2" Carton Dimensions Width 40 9/16" Depth 171/4" Height 291/2" Net Weight 100.3 Ibs. Gross Weight 108.7lbs. Cooling Operating Temperature 5 °F- 122 °F Heating Operating Temperature -13 °F - 75 °F Airflow (CFM) 1765 Sound Pressure (dB(A)) 58.5 Fan Speed (r/min) Low 500 High 750 Fan Motor Current Type DC COMPRESSOR Type DC Inverter Twin Cylinder Rotary Oil Type VG74 Oil Charge (oz.) 15.2 (450 ml) Specifications are subject to change without notice. © 2022 Ferguson Enterprises LLC www.durastar.com Form No. V1.0_10.22 26 1 /2" (673 m m) 13 7/16"1 18,000 BTU/H MULTI -ZONE HEAT PUMP SYSTEM ODU DIMENSIONS - DRA2U18M1 B Clearances QJ 0 a E E 0 Dimensions �39" (990mm) 351/16"(890mm) 0 O O (610 on ri9hrnr,) i" (354mm) NOTE Illustrations in this document are for explanatory purposes. The actual shape of your mini -split equipment may vary slightly. Specifications are subject to change without notice. O 2022 Ferguson Enterprises LLC www.durostar.com 3 Form No. V1.0_10.22