Loading...
HomeMy WebLinkAboutREDLINED ENGINEER PLANS - 22-00474 - Transfer Station - New Scale HouseAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Alex Owens Alex.Owens@rexburg.org 208-372-2330 Don Allen Don.Allen@rexburg.org 208-372-2174 Description : Transfer Station - New Scale House Address : 529 Airport Rd Application Type : Document Filename : Madison County Transfer Station arch drawings 1-31-22.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A1.1 Free text Cody Jones : Building Open 5 Restroom to meet all ADA requirements. A1.1 Free text Cody Jones : Building Open 5 If exterior walls are not insulated office walls will need to meet R values required. A1.1 Free text Cody Jones : Building Open 5 Due to sheeting building to be VB. A1.1 Free text Cody Jones : Building Open 5 Building is located in flood plain. Flood plain certificate and elevation required. S1.0 Free text Cody Jones : Building Open 13 Ben M. stated Connect Eng. will be doing special inspections. E1.0 Free text Alex Owens : Electrical Open 20 Verify wiring method to be used. All electrical work to comply with 2017 NEC. E2.0 Callout Alex Owens : Electrical Open 21 Available fault current calculation needed. E2.0 Callout Alex Owens : Electrical Open 21 Ensure this AIC rating of this breaker is sufficient # 22-00474 New Commercial Building Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 07.25.2022 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) Building is located in flood plain. Flood plain certificate and elevation required. Restroom to meet all ADA requirements. Due to sheeting building to be VB. If exterior walls are not insulated office walls will need to meet R values required. JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . AN Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER: CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com RMSDBPIF21-294 PR O FES S I O N A L ENGINEER STATEOF I D A HOA11 / 1 5 / 2 1 14 1 3 4 D VID B . P O R T ER L I C E NSED STRUCTURAL ENGINEERING GENERAL STRUCTURAL NOTES (APPLY UNLESS NOTED OTHERWISE ON PLANS/DETAILS) GENERAL REQUIREMENTS: 1.THE STRUCTURAL SYSTEMS AND MEMBERS DEPICTED HEREIN HAVE BEEN DESIGNED PRIMARILY TO SAFEGUARD AGAINST MAJOR STRUCTURAL DAMAGE AND LOSS OF LIFE, NOT TO LIMIT DAMAGE OR MAINTAIN FUNCTION (IBC SECTION 101.3). 2.THESE DRAWINGS, AND THEIR ASSOCIATED STRUCTURAL CALCULATIONS, HAVE BEEN PERFORMED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE STRUCTURAL ENGINEER'S IN THIS OR SIMILAR LOCALITIES. THEY NECESSARILY ASSUME THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKMEN WHO HAVE A WORKING KNOWLEDGE OF THE INTERNATIONAL BUILDING CODE CONVENTIONAL FRAMING REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR FRAMING ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, IT IS UNDERSTOOD THAT THE CONTRACTOR WILL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR ALL MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3.THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION SUCH THAT DESIGN LIVE LOAD PER SQUARE FOOT AS STATED HEREIN IS NOT EXCEEDED. OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF AN OPTION IS USED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES, AND SHALL COORDINATE ALL DETAILS. 4.WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. TYPICAL DETAILS AND NOTES ARE NOT NECESSARILY INDICATED ON THE PLANS, BUT SHALL APPLY NONE-THE-LESS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. DETAILS MAY SHOW ONLY ONE SIDE OF CONNECTION OR MAY OMIT INFORMATION FOR CLARITY. 5.ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ARCHITECT AND STRUCTURAL ENGINEER. 6.ANY INSPECTIONS, SPECIAL (IBC CHAPTER 17) OR OTHERWISE THAT ARE REQUIRED BY THE BUILDING CODES, LOCAL BUILDING DEPARTMENTS, OR BY THESE PLANS SHALL BE DONE BY AN INDEPENDENT INSPECTION COMPANY OR THE BUILDING DEPARTMENT, SITE VISITS BY THE STRUCTURAL ENGINEER DO NOT CONSTITUTE AN OFFICIAL INSPECTION, UNLESS SPECIFICALLY CONTRACTED FOR. BASIS FOR DESIGN: 1. BUILDING CODE: 2018 EDITION OF THE IBC WITH CITY/COUNTY AMENDMENTS. RISK CATEGORY = II 4. SEISMIC DESIGN PARAMETERS: ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE IMPORTANCE FACTOR Ie = 1.00 SITE CLASS D SEISMIC DESIGN CATEGORY D MAPPED SPECTRAL RESPONSE ACCELERATIONS S1 = 0.152, SS = 0.470 DESIGN SPECTRAL RESPONSE ACCELERATIONS SD1 = 0.222, SDS = 0.446 PERCENT SNOW INCLUDED WITH SEISMIC LOADS 20 VERTICAL SHEAR TRANSFER ELEMENTS: PLYWOOD SHEARWALL(S)R = 6.5, CS = 0.069 5. WIND DESIGN PARAMETERS (STRENGTH): ULTIMATE WIND SPEED 115 MPH (3 SECOND GUST) WIND EXPOSURE C IMPORTANCE FACTOR Iw = 1.00 INTERNAL PRESSURE COEFFICIENT -0.18 COMPONENT AND CLADDING PRESSURE 27.3 PSF NET UPLIFT ON ROOF 18.0 PSF 2. VERTICAL LOADS: LOCATION LIVE / SNOW LOAD DEAD LOAD ROOF 125 PSF 15 PSF 3. DEFLECTION LIMITS: ELEMENTS LIVE LOAD TOTAL LOAD ROOF TRUSSES/JOISTS L/360 L/240 BEAMS L/360 L/240 FOUNDATION NOTES: 1. IN LIEU OF A GEOTECHNICAL REPORT: THE FOUNDATION HAS BEEN DESIGNED ACCORDING TO THE RECOMMENDATIONS OF CHAPTER 18 OF THE IBC. 2. THE SOIL DESIGN VALUES LISTED BELOW HAVE BEEN APPROVED BY THE CITY/COUNTY BUILDING DEPARTMENT, CONTINGENT THAT THE SOIL ON THE SITE PREDOMINATELY CONSISTS OF SAND AND/OR GRAVEL. SPECIFIC SOIL CLASSIFICATIONS SHOULD BE ONE OF THE FOLLOWING: SANDY GRAVEL OR GRAVEL(GW OR GP), SAND(SW AND SP), SILTY SAND(SM), CLAYEY SAND(SC), SILTY GRAVEL(GM), OR CLAYEY GRAVEL(GC). THESE SOIL CLASSIFICATIONS CAN BE FOUND IN TABLE 1806.2 OF CHAPTER 18 OF THE IBC. VERIFICATION OF SOIL CLASSIFICATION IS THE RESPONSIBILITY OF THE CONTRACTOR. 3.A ONE-THIRD INCREASE IN BEARING PRESSURES IS ALLOWED WITH SEISMIC OR WIND LOAD COMBINATIONS. LATERAL BEARING AND LATERAL SLIDING RESISTANCE MAY BE COMBINED. 4.ALL FOUNDATIONS SHALL BEAR ON COMPACTED ENGINEERED FILL OR COMPETENT NATIVE SOIL SUBBASE COMPACTED TO 95% DRY DENSITY (STANDARD PROCTOR). GRADE IS DEFINED AS LOWEST ADJACENT GRADE WITHIN 5 FEET OF THE BUILDING FOR PERIMETER FOOTINGS. WHERE EXTERIOR PAVING OR CONCRETE IS DIRECTLY ADJACENT TO BUILDING, GRADE IS DEFINED AS TOP OF EXTERIOR PAVING AT LEAST 5 FEET FROM BUILDING. CONCRETE FOOTING EXCAVATIONS SHALL BE CLEAN AND FREE OF LOOSE DEBRIS OR UN-COMPACTED MATERIAL AT TIME OF CONCRETE PLACEMENT. 5. CONCRETE SLABS ON GRADE SHALL BE SUPPORTED ON A 4 INCH (MIN) LAYER OF FREE-DRAINING GRANULAR MAT (DRAINAGE FILL COURSE). THE MAT SHOULD CONSIST OF A WELL GRADED SAND AND GRAVEL MIXTURE WITH MAXIMUM 3/4-INCH CRUSHED AGGREGATE. THE GRANULAR MAT SHOULD BE COMPACTED TO NO LESS THAN 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D1557. 6.BACKFILL AGAINST RESTRAINED WALLS SHALL NOT BE PLACED UNTIL AFTER THE WALLS ARE SUPPORTED BY THE COMPLETION OF INTERIOR FLOOR SYSTEMS AND CONCRETE OR GROUT STRENGTH HAS REACHED THE 28 DAY STRENGTH LISTED BELOW. THE SOIL DESIGN VALUES FOR THE FOUNDATION ARE: ALLOWABLE BEARING PRESSURE 1500 PSF ALLOWABLE LATERAL BEARING PRESSURE 150 PSF/FT ALLOWABLE LATERAL SLIDING COEFFICIENT 0.25 FOUNDATION BEARING DEPTH 36" BELOW FINISHED GRADE CONCRETE: 2. ALL NORMAL WEIGHT CONCRETE SHALL BE REGULAR WEIGHT OF 150 POUNDS PER CUBIC FOOT USING HARD-ROCK AGGREGATES. AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. 3.LAP SPLICES FOR BEAMS AND FLOOR SLABS SHALL BE ACCORDING TO CHAPTER 12 OF ACI 318 OR LAP SCHEDULE ON THESE DRAWINGS. STAGGER SPLICES A MINIMUM OF ONE LAP LENGTH. NO TACK WELDING OF REINFORCING BARS ALLOWED WITHOUT PRIOR REVIEW OF PROCEDURE WITH THE STRUCTURAL ENGINEER. LATEST ACI CODE AND DETAILING MANUAL APPLY. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. VERTICAL WALL BARS SHALL BE SPLICED AT OR NEAR FLOOR LINES. 4.ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING STEEL NOT NOTED AS "CLEAR" OR "CLR" ARE TO CENTER OF STEEL. MINIMUM COVER FOR NON-PRESTRESSED CONCRETE REINFORCING SHALL BE AS FOLLOWS: 5.MAXIMUM SLUMP FOR ALL CONCRETE SHALL BE 6". PORTLAND CEMENT SHALL CONFORM TO ASTM C150. TYPE V CEMENT SHALL BE USED FOR CONCRETE IN CONTACT WITH ALKALINE SOIL, AND TYPE II ELSEWHERE. 6.NO MORE THAN 90 MINUTES SHALL ELAPSE BETWEEN CONCRETE BATCHING AND CONCRETE PLACEMENT UNLESS APPROVED BY THE TESTING AGENCY. 7.CONCRETE PLACEMENT AND QUALITY SHALL BE PER RECOMMENDATIONS IN ACI 614, ACI 301 AND ACI 318. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS ON GRADE NEED BE VIBRATED ONLY AROUND AND UNDER FLOOR DUCTS, ETC. CAST CLOSURE POUR, WHERE SHOWN ON PLANS AROUND COLUMNS AFTER COLUMN DEAD LOAD IS APPLIED. REMOVE ALL DEBRIS FROM FORMS BEFORE PLACING CONCRETE. ALL ITEMS TO BE CAST IN CONCRETE SUCH AS REINFORCING, DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY POSITIONED IN THE FORMS BEFORE PLACING THE CONCRETE. 8.ALL CONCRETE SLABS ON GRADE SHALL BE DIVIDED INTO AREAS BY CONTROL JOINTS (KEYED OR SAW CUT) SUCH THAT ONE SLAB AREA DOES NOT EXCEED A MAXIMUM LENGTH OF 24 TIMES THE SLAB THICKNESS IN BOTH DIRECTIONS (EXAMPLE: 4" SLAB = 8'-0" LENGTH). SQUARE LAYOUTS ARE PREFERRED, BUT THE SLAB GEOMETRY MAY DICTATE OTHERWISE. THE RATIO OF THE LONG TO SHORT DISTANCE SHALL NOT EXCEED 1.3. IT IS RECOMMENDED THAT SAW CUTS BE MADE WITHIN 16 HOURS OF CONCRETE BATCHING. KEYED CONTROL JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING POURING, ALL OTHER JOINTS MAY BE SAW CUT. 9. HORIZONTAL PIPES AND ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE AND SLABS ON GRADE EXCEPT WHERE SPECIFICALLY APPROVED OR NOTED BY THE STRUCTURAL ENGINEER. PIPES AND CONDUITS SHALL NOT IMPAIR THE STRENGTH OF THE WORK. 10. FLY ASH MAY BE USED ONLY IF PERMITTED BY ARCHITECTURAL SPECIFICATIONS AND SHALL BE LIMITED TO 18 PERCENT OF CEMENTITIOUS MATERIALS AND SHALL HAVE A REPLACEMENT FACTOR OF 1.2 RELATIVE TO CEMENT REPLACED. NO FLY ASH ADDITIVES SHALL BE USED IN FLATWORK OR ARCHITECTURALLY EXPOSED CONCRETE. 11.COLD/HOT WEATHER CONCRETE CONSTRUCTION: PROTECT CONCRETE FROM DAMAGE OR REDUCED STRENGTH IN COMPLIANCE WITH ACI 305 AND 306. 12.CONCRETE MIXES SHALL BE DESIGNED BY A CERTIFIED LABORATORY AND APPROVED BY THE STRUCTURAL ENGINEER. 13.LIMIT ALKALI-SILICA REACTION (ASR) TO 0.1% EXPANSION AT 28 DAYS IN CONCRETE MIX AT ALL EXTERIOR CONCRETE AND INTERIOR CONCRETE EXPOSED TO MOISTURE. LOCATION:MINIMUM COVER TOLERANCE CAST AGAINST EARTH (FOOTINGS)3" ± 38" SLABS ON GRADE 1 12"± 14" EXPOSED TO EARTH OR WEATHER - #5 AND SMALLER 1 12"± 38" EXPOSED TO EARTH OR WEATHER - #6 AND LARGER 2" ± 38" NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND ROOF SLAB 1"18" STRUCTURAL SLABS AND WALLS 34"18" BEAMS AND COLUMNS (PRIMARY) REINFORCEMENT, TIES, STIRRUPS AND SPIRALS 112"38" 1. MINIMUM 28 DAY CONCRETE STRENGTH SHALL BE AS FOLLOWS: USE:CONCRETE STRENGTH: MAX W/C RATIO AIR ENTRAINMENT FOOTINGS 3500 PSI 0.50 5.5% ± 1% FOUNDATION WALLS 4500 PSI 0.45 5.5% ± 1% INTERIOR CONCRETE SLABS ON GRADE 3500 PSI 0.45 5.5% ± 1% REINFORCING STEEL: 1. ASTM A615 GRADE 60 (FY = 60 KSI) DEFORMED BARS FOR ALL BARS #4 AND LARGER. ASTM A615 GRADE 40 (FY = 40 KSI) DEFORMED BARS FOR ALL BARS #3 AND SMALLER. GRADE 60 DEFORMED BARS SHALL BE USED FOR CONCRETE WALLS, BEAMS, ELEVATED SLABS AND COLUMN REINFORCING. 2. WELDING OF REINFORCING BARS SHALL BE MADE ONLY TO ASTM A706 GRADE 60 BARS AND ONLY USING E90 SERIES RODS. WELDING OF REINFORCING BARS SHALL BE MADE ONLY AT LOCATIONS SHOWN ON PLANS OR DETAILS. 3.REINFORCING BAR SPACING GIVEN ARE MAXIMUM ON CENTERS. ALL BARS PER CRSI SPECIFICATIONS AND HANDBOOK. DOWEL ALL VERTICAL REINFORCING TO FOUNDATION. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. WOOD: 1.GENERAL: DO NOT NOTCH OR DRILL JOISTS, BEAMS, OR LOAD BEARING STUDS WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER THROUGH THE ARCHITECT. DOUBLE UP JOISTS AND BLOCKING UNDER PARTITIONS. PROVIDE 2" (NOMINAL) SOLID BLOCKING AT SUPPORTS OF ALL JOISTS. UNLESS NOTED OTHERWISE ON PLANS/DETAILS PROVIDE 2x SOLID BLOCKING AT MID-HEIGHT OF BEARING STUD WALLS. ALL NAILING NOT NOTED SHALL BE ACCORDING TO IBC TABLE 2304.10.1. JOIST HANGERS AND OTHER MISC. FRAMING ANCHORS SHALL BE SIMPSON STRONG-TIE COMPANY, INC. OR OTHER MANUFACTURER WITH CURRENT ICC-ES APPROVAL. 2. SAWN LUMBER: FRAMING LUMBER SHALL COMPLY WITH THE LATEST EDITION OF THE GRADING RULES OF THE WESTERN WOOD PRODUCTS ASSOCIATION (WWPA) OR THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB). ALL SAWN LUMBER SHALL BE STAMPED WITH THE GRADE MARK OF AN APPROVED LUMBER GRADING AGENCY. SAWN LUMBER SHALL HAVE THE FOLLOWING MINIMUM GRADE UNLESS NOTED OTHERWISE IN SCHEDULES: USE: MATERIAL: 2x4 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) 2x6 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) JOISTS, TOP PLATES AND ALL OTHER SAWN LUMBER DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) BEAMS AND POSTS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) LOCATION:NOMINAL THICKNESS: SPAN INDEX RATING: EDGE ATTACHMENT: FIELD ATTACHMENT: WALL 716" OR 12"2416 8d AT 6" O.C. 8d AT 12" O.C. ROOF 716" OR 12"2416 8d AT 6" O.C. 8d AT 12" O.C. ROOF 1532" OR 12"3216 8d AT 6" O.C. 8d AT 12" O.C. ROOF 1932" OR 58"4020 10d AT 6" O.C. 10d AT 12" O.C. ROOF 23 32" OR 34"4824 10d AT 6" O.C. 10d AT 12" O.C. ROOF 78"6032 10d AT 6" O.C. 10d AT 12" O.C. FLOOR 3 4" T&G 4824 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 78" T&G 6032 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 118" T&G 6048 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. 3.PLYWOOD: ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING CONFORMING TO STANDARD PS 1-95. LAY UP PLYWOOD WITH FACE GRAIN IN PERPENDICULAR TO SUPPORTS (ON ROOFS WHERE PLYWOOD IS LAID UP WITH FACE GRAIN PARALLEL TO SUPPORTS, USE A MINIMUM OF 5-PLY PLYWOOD, STAGGER JOINTS). ALL NAILING, COMMON NAILS. BLOCKING AT PANEL EDGES WHERE INDICATED ON PLANS. ALL PLYWOOD SHALL BE OF THE FOLLOWING NOMINAL THICKNESS, SPAN/INDEX RATING AND SHALL BE NAILED AS FOLLOWS UNLESS NOTED OTHERWISE ON THE PLANS: SHEET INDEX SHEET DESCRIPTION DETAILS S1.0 GENERAL STRUCTURAL NOTES --- S1.1 TYPICAL DETAILS T-SERIES S2.0 FOUNDATION PLAN --- S2.1 ROOF FRAMING PLAN --- S3.0 DETAILS 100 - 200 SERIES CAST IN PLACE CENTERLINE CENTERLINE OF BEAM CENTERLINE OF COLUMN CENTERLINE OF WALL CLEAR CONCRETE CONCRETE CONTROL JOINT CONCRETE SAWCUT JOINT CONCRETE MASONRY UNIT CONNECTION CONTINUOUS DEAD LOAD DOWN DRAWING(S) EQUAL EQUIPMENT EXPANSION JOINT EACH WAY FINISHED FLOOR FACE OF STEEL FACE OF WALL GAUGE GALVANIZED GENERAL STRUCTURAL NOTES CENTERLINE OF FOOTING FACE OF MEMBER EXPANSION BOLT EDGE OF SLAB DIAMETER GALV GSN DN. DWG(S) EQ EQUIP EXP. JT (E.J.) E.W. F.F. F.O.S. F.O.W. GA F.O.M. EXP. BOLT E.O.S. Ø OR DIA. C.I.P. C L C.L.B. C.L.C. C.L.W. CLR CONC C.C.J. C.S.J. C.M.U. CONN. CONT D L C.L.F. W/ WITH W/O WITHOUT T.O.P. U.N.O. W.W.F. TYP VERT T.O.S. T.O.W. T.O.D. T.O.F. T.O.L. T.O.M. STD T.O.B. T L SLH SLV SIM SQ PSF PSI REINF PREFAB OPP P.C. PLF N.T.S. O.C. O.F.W. TOP OF FOOTING UNLESS NOTED OTHERWISE WELDED WIRE FABRIC TOP OF MASONRY TOP OF PLATE TOP OF STEEL TOP OF WALL TYPICAL VERTICAL STANDARD TOP OF BEAM TOP OF DECK TOP OF LEDGER TOTAL LOAD OUTSIDE FACE OF WALL PRECAST CONCRETE POUNDS PER LINEAR FOOT POUNDS PER SQUARE INCH SHORT LEG VERTICAL SHORT LEG HORIZONTAL REINFORCING SIMILAR SQUARE NOT TO SCALE ON CENTER OPPOSITE PREFABRICATED AGGREGATE BASE COURSE AIR CONDITIONER ABOVE FINISHED FLOOR ALTERNATE ANCHOR BOLT AT (MEASUREMENT) BEAM BOTTOM OF BEAM BOTTOM OF DECK BEARING BELOW FINISHED FLOOR BOTTOM OF FOOTING A.B.C. A/C A.F.F. ALT A.B. @ BM B.O.B. B.O.D. BRG B.F.F B.O.F. ABBREVIATIONS LBS (#) MFR('S) M.C.J. MECH N/A LLV LLH HORIZ K(KIP) L L LONG LEG VERTICAL MANUFACTURER('S) MASONRY CONTROL JOINT NOT APPLICABLE LONG LEG HORIZONTAL POUNDS MECHANICAL HORIZONTAL 1000 POUNDS LIVE LOAD EXISTING(E) MIN MINIMUM MAX MAXIMUM POUNDS PER SQUARE FOOT GLUED-LAMINATED BEAMGLB PFT PREFAB FLOOR TRUSSES PRT PREFAB ROOF TRUSSES I.F.W.INSIDE FACE OF WALL PT PRESSURE TREATED CONCRETE COLUMNC.C. RME ROOF MOUNTED EQUIPMENT SCREWS AT FLOOR SHEATHING SHALL BE #8 SCREWS AND SHALL PENETRATE AT LEAST 112" INTO THE SUPPORTING MEMBER. ALL FLOOR SHEATHING SHALL BE GLUED TO SUPPORTING MEMBERS WITH AN APA AFG-01 QUALIFIED GLUE. PLYWOOD ALTERNATE: AMERICAN PLYWOOD ASSOCIATION PERFORMANCE RATED SHEATHING MAY BE USED AS AN ALTERNATE TO PLYWOOD WITH PRIOR APPROVAL OF OWNER, ARCHITECT AND ROOFER. IT MAY NOT BE USED ON ROOFS WHERE BUILT-UP ROOF SYSTEM IS TO BE GUARANTEED BY ROOFER. RATED SHEATHING SHALL COMPLY WITH CURRENT ICC-ES REPORTS AND SHALL HAVE A SPAN RATING EQUIVALENT TO OR BETTER THAN THE PLYWOOD IT REPLACES. ATTACHMENT AND THICKNESS (WITHIN 132") SHALL BE THE SAME AS THE PLYWOOD IT REPLACES. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 4.NOMINAL 2x AND 3x DECKING. TONGUE AND GROOVE TYPE. MINIMUM Fb = 1,600 PSI, MINIMUM E = 1,300,000 PSI. INSTALL WITH TONGUES UP SLOPE ON PITCHED ROOFS, AND OUTWARD IN THE DIRECTION OF LAYING ON FLAT ROOFS. NAIL EACH PLANK WITH 16d TOENAIL (THRU THE TONGUE) AND 16d FACE NAIL AT EACH SUPPORT. DECK SHALL BE INSTALLED AS SIMPLE SPAN WITH ALL PLANKS BEARING ON TWO SUPPORTS. FOR REFERENCE AND/OR ADDITIONAL INFORMATION SEE AITC 117-2010. 5.GLUED-LAMINATED BEAMS (GLB): GLUED-LAMINATED BEAMS SHALL BE DOUGLAS FIR COMBINATION AT 24F-V4 AT SIMPLE SPAN BEAMS AND 24F-V8 AT MULTI-SPAN AND CANTILEVERED BEAMS WITH THE FOLLOWING MINIMUM PROPERTIES: FB = 2,400 PSI, FV = 190 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,800 KSI. ALL BEAMS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. BEAMS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. CAMBER AS SHOWN ON DRAWINGS. STANDARD CAMBER IS BASED ON A RADIUS OF CURVATURE OF 2000 FEET. 6. GLUED-LAMINATED COLUMNS: GLUED-LAMINATED COLUMNS SHALL BE DOUGLAS FIR COMBINATION 3 WITH THE FOLLOWING MINIMUM PROPERTIES: FBY = 2,100 PSI, FBX = 2000 PSI, FVY = 230 PSI, FVX = 265 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,900 KSI. ALL COLUMNS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. COLUMNS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. 7.LAMINATED VENEER LUMBER (LVL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LVLs SHALL BE: FB = 2,600 PSI, FV = 285 PSI, E = 2,000 KSI. 8.PARALLEL STRAND LUMBER (PSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR PSLs SHALL BE: FB = 2,900 PSI, FV = 290 PSI, E = 2,000 KSI. 9.LAMINATED STRAND LUMBER (LSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LSLs SHALL BE: FB = 2,325 PSI, FV = 310 PSI, E = 1,550 KSI. 10. SILL PLATES RESTING ON CONCRETE OR MASONRY SHALL BE OF TREATED FIR. SHEAR WALLS AND EXTERIOR WALL SILLS AT CONCRETE SLAB SHALL HAVE A MINIMUM OF (2) ANCHOR BOLTS PER PIECE. PROVIDE ANCHOR BOLT AT 9" MAXIMUM, 4" MINIMUM FROM THE END OF EACH PIECE AT SPLICE OR END OF WALL. MAXIMUM ANCHOR BOLT SPACING SHALL BE 72" ON CENTER UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. ALL ANCHOR BOLTS (OTHER THAN BOLTS FOR HOLDOWNS) SHALL EMBED 7" INTO CONCRETE. ANCHOR BOLTS FOR HOLDOWNS SHALL NOT BE CONSIDERED AS PART OF REQUIRED ANCHOR BOLTS ON SHEAR WALLS. ALL EXTERIOR WALLS SHALL BE SECURED WITH MINIMUM ANCHOR BOLTS. INTERIOR WALLS MAY BE SECURED TO CONCRETE WITH EITHER ANCHOR BOLTS OR POWER DRIVEN SHOT PINS UNLESS NOTED OTHERWISE ON PLANS. 11.BOLTING: ALL BOLTS IN WOOD CONNECTIONS SHALL CONFORM TO ASTM A307. BOLTS SHALL BE INSTALLED IN HOLES BORED WITH A BIT 116" LARGER THAN THE Ø (DIAMETER) OF THE BOLT. BOLTS AND NUTS SEATING ON WOOD SHALL HAVE CUT STEEL WASHERS UNDER HEADS AND NUTS. NICK THREADS TO PREVENT LOOSENING. 12.PREFABRICATED WOOD TRUSSES: PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED TO SUPPORT SELF WEIGHT PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS. WHERE UNINHABITABLE ATTIC SPACE CAN BE USED FOR STORAGE, A 20 PSF LIVE LOAD ON THE BOTTOM CHORD SHALL BE INCLUDED IN THE ANALYSIS. BRIDGING SIZE AND SPACING BY TRUSS MANUFACTURER UNLESS NOTED OTHERWISE. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED ENGINEER FOR REVIEW PRIOR TO MANUFACTURE FOR BOTH ROOF AND FLOOR TRUSSES WHEN USED. SHOP DRAWINGS SHALL SHOW ANY SPECIAL DETAILS REQUIRED AT BEARING POINTS. ALL CONNECTORS SHALL HAVE CURRENT ICC-ES APPROVAL. ADDITIONAL TRUSSES SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. PER IBC SECTION 2303.4 AND TPI-1: EACH TRUSS SHALL BE LEGIBLY BRANDED, MARKED OR OTHERWISE HAVE PERMANENTLY AFFIXED THERETO THE IDENTITY OF THE COMPANY MANUFACTURING THE TRUSS, THE DESIGN LOADS, AND THE TRUSS SPACING - WITHIN TWO FEET OF THE CENTER OF THE SPAN ON THE FACE OF THE BOTTOM CHORD. PREFABRICATED WOOD/STEEL WEB JOIST/PURLINS (TJI/TJL SERIES OR EQUAL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST EDITION ICC-ES REPORT. CONNECTIONS AND BEARING MATERIAL TO BE DESIGNED AND FURNISHED BY JOIST FABRICATOR. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED STRUCTURAL ENGINEER FOR REVIEW PRIOR TO MANUFACTURE. ADDITIONAL JOISTS SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. PRE-ENGINEERED BUILDING DESIGN CRITERIA: 1.DESIGN: PRE-ENGINEERED BUILDING MANUFACTURER SHALL BE RESPONSIBLE FOR THE ENTIRE DESIGN OF THE STEEL SUPERSTRUCTURE, ROOF, DECK, FASCIAS, SUPPORT, BRACING, LATERAL ANALYSIS AND ALL RELATED WORK. 2.BUILDING CODE: THE ENTIRE SUPERSTRUCTURE, INCLUDING THE ROOF DECK, SHALL BE DESIGNED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. WIND PRESSURES FOR ENCLOSED, PARTIALLY ENCLOSED AND UNENCLOSED BUILDING AREAS SHALL BE CONSIDERED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. THE PRE-ENGINEERED BUILDING SHALL BE DESIGNED TO SUPPORT SELF WEIGHT PLUS SUPERIMPOSED DEAD, LIVE, WIND OR SEISMIC LOADING, WHICHEVER COMBINATION PRODUCES THE MOST SEVERE CONDITION, IN ACCORDANCE WITH THE LATEST RECOMMENDATIONS OF THE METAL BUILDING MANUFACTURERS ASSOCIATION(MBMA). 3. SHOP DRAWINGS: CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED STRUCTURAL ENGINEER FOR REVIEW PRIOR TO MANUFACTURE. SHOP DRAWINGS SHALL SHOW ALL INFORMATION INCLUDING, BUT NOT LIMITED TO, DIMENSIONS, MEMBER SIZES AND PROPERTIES, FRAMING PLANS, SECTIONS AND ALL PERTINENT DETAILS. 4.PURLINS AND DECK: STEEL PURLIN SPACING AND STEEL DECK SELECTION SHALL BE THE OPTION OF THE PRE-ENGINEERED BUILDING MANUFACTURER. 5.MISCELLANEOUS FRAMING: PRE-ENGINEERED BUILDING MANUFACTURER SHALL SUPPLY ALL THE REQUIRED SUB-FRAMING FOR ROOF OPENINGS, INCLUDING FRAMING TO SUPPORT THE WEIGHT OF MECHANICAL EQUIPMENT. ALL ITEMS INCLUDING ROOF OPENINGS SHALL BE SUPPORTED. Ben M. stated Connect Eng. will be doing special inspections. KEYNOTES: 1. FINISHED GRADE WHERE OCCURS 2. DO NOT EXCAVATE A TRENCH CLOSER THAN A 45° ANGLE TO BELOW BOTTOM FOOTING OR FOUNDATION 3.BOTTOM OF CONCRETE FOOTING 4. BOTTOM OF TRENCH NOTE: A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPE OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T1 TRENCH PARALLEL TO CONTINUOUS STRIP FOOTING TD01 NO SCALE 1 1 4 3 2 1 KEYNOTES: 1.CONCRETE FOOTING 2.SLEEVE - PROVIDE 12" MINIMUM CLEARANCE AROUND PIPE OR CONDUIT 3. PIPE OR CONDUIT 4.CONCRETE FILL TO BE PLACED BEFORE FOOTING IS POURED - FORM SAME AS FOOTING AND POUR FULL WIDTH OF PIPE TRENCH 5.STEM WALL NOTE: A.NO PIPE SHALL PASS THRU FOOTING OR UNDER COLUMN FOOTINGS. FOR TRENCHES GREATER THAN 3'-6" BELOW BOTTOM OF FOOTING, SEE PIPE PASSING BELOW WALL FOOTING DETAIL. T2 PIPE PASSING UNDER WALL FOOTING IN SHALLOW TRENCH TD02 NO SCALE 6" M I N 8" M I N 3' - 0 " M A X 8" MIN A SECTIONA 5 1 2 3 4 5 1 2 3 4 KEYNOTES: 1.STEM WALL 2. CONCRETE FOOTING 3.1'-6" MAXIMUM (WHERE TRENCH EXCEEDS 1'-6" NOTIFY STRUCTURAL ENGINEER PRIOR TO PLACEMENT OF FOOTINGS) 4.BACKFILL AND RECOMPACT TRENCH PER SOILS REPORT AND SPECIFICATIONS 5.BOTTOM OF TRENCH NOTE: A. DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPES OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS 3'- 1 " O R G R E A T E R FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T3 PIPE PASSING BELOW FOOTING IN DEEP TRENCH TD03 NO SCALE 5 3 2 1 44 1 KEYNOTES: 1. SLOPED FINISH GRADE 2. MINIMUM FOOTING DEPTH PER G.S.N. (12" MINIMUM) 3.DEEPEN FOOTING AS REQUIRED TO ACCOUNT FOR SLOPED GRADE 4. CONCRETE FOOTING NOTE: A.FOR ADDITIONAL INFORMATION, SEE PLANS AND DETAILS 5'-0" T4 TYPICAL DETAIL FOR FOUNDATION EMBEDMENT TD04 NO SCALE 1 2 3 4 KEYNOTES: 1.CORNER DOWELS TO MATCH HORIZONTAL REINFORCEMENT 2.CONCRETE WALL WITH REINFORCEMENT 18" MIN LAP SPLICE (TYP) T5 TYPICAL CONCRETE CORNER TD05 NO SCALE 2 1 KEYNOTES: 1.CONCRETE SLAB ON GRADE 2. CONT KEYED JOINT 3.SAWCUT 18" WIDE x 14 SLAB THICKNESS IN DEPTH - CUT SHALL BE MADE SOON ENOUGH TO PREVENT SHRINKAGE CRACKING, BUT NOT SO SOON AS TO CAUSE SPALLING OF THE CONCRETE WHILE SAWING. WORK MUST BE COMPLETE WITHIN 16 HOURS OF CONCRETE PLACEMENT. NOTE: A.KEYED JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING PLACEMENT UNLESS SPECIFICALLY NOTED ON THE PLANS. B."TOOL WET JOINT", "ZIP STRIP", ETC SHALL MATCH SAWCUT REQUIREMENTS 12"6"6"12" SAWCUT JOINT KEYED JOINT T6 CONTROL JOINTS IN CONCRETE SLAB ON GRADE TD07 NO SCALE 1 3 1 2 NOTES: 1. TOP BARS ARE ANY HORIZONTAL BARS PLACED SO THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT. 2. UNLESS NOTED OTHERWISE, LAP SPLICES IN CONCRETE BEAMS, SLABS AND WALLS SHALL BE CLASS "B" TENSION LAP SPLICES. BAR SIZE CLASS B TENSION SPLICE LENGTHS f'c = 3,000 PSI f'c = 4,000 PSI f'c = 5,000 PSI HORIZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HORIZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HORIZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS #3 12" 12" 12" 12" 12" 12" #4 19" 15" 17" 13" 15" 12" #5 29" 23" 26" 20" 23" 18" #6 32" 25" 28"21"25" 19" #7 54" 41" 47" 36" 42" 32" #8 70"54"61" 47"54"42" #9 89" 68"77"59" 69" 53" #10 112" 87" 97" 75" 87" 67" T7 STEEL REINFORCING LAP SPLICES IN CONCRETE TD14 NO SCALE T8 ELEVATION-TYPICAL 1-STORY SHEARWALL TD19 NO SCALE KEYNOTES: 1. SHEATHING MATERIAL 2.DOUBLE STUDS AT EACH END OF SHEARWALL, EDGE NAIL ALONG DOUBLE STUDS 3. FULL HEIGHT WOOD STUDS 4.BOTTOM PLATE ATTACHMENT 5.SIMPSON STHD TYPE HOLDOWN 6. MIDHEIGHT BLOCKING AND EDGE NAILING REQUIRED 7.SIMPSON "PHD" TYPE HOLDOWN 8.FINISHED FLOOR 9.CONT 2x PT SOLE PLATE 1 3 6 8 7 4 5 2 9 KEYNOTES: 1. NAILS BETWEEN SPLICE LOCATION PER SCHEDULE - STAGGERED 2. DBL 2x TOP PLATE 3. WOOD STUD WALL, SEE PLAN 4.SPLICE OVER STUD 5.SIMPSON ST6224 OR MSTC40 STRAP AT LOCATIONS WHERE PLATES CAN NOT BE SPLICED NOTE: A.DO NOT SPLICE TOP PLATES WITHIN 6'-0" OF ENDS OF PLYWOOD SHEARWALLS. THIS DETAIL REQUIRED AT ALL EXTERIOR WALLS AND OVER SHEARWALLS - NOT REQUIRED AT INTERIOR NON-SHEARWALLS. (30) 16d (24) 16dLESS THAN 20' OVER 20' 4'-0" 6'-0" LENGTH OF WALL (BETWEEN CORNERS) SPLICE LENGTH NAILS ALONGSPLICE LENGTH MINIMUM SPLICE LENGTH PER SCHEDULE T9 ELEVATION - TYPICAL TOP PLATE SPLICE TD24 NO SCALE 4 5 1 3 2 3 2 KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2. WOOD HEADER 3. KING STUD(S) PER PLAN 4. (2) 16d NAILS AT 2" O.C. 5.16d NAILS AT 12" O.C. 6.TRIMMER STUD(S) PER PLAN 2 6 3 1 5 4 5 T10 TYPICAL HEADER CONNECTION TD25 NO SCALE NOTE: A.MINIMUM STAPLING SPECIFIED HEREIN SHALL BE PROVIDED UNLESS NOTED OTHERWISE ON PLANS, DETAILS OR GENERAL STRUCTURAL NOTES 8d COMMON AT 12" O.C.16 GA STAPLE AT 12" O.C. ALTERNATE FASTENER SCHEDULE ALTERNATE FASTENERSPECIFIED FASTENER 8d COMMON AT 6" O.C. 8d COMMON AT 4" O.C. 15 GA STAPLE AT 12" O.C. 14 GA STAPLE AT 12" O.C. 13 GA STAPLE AT 12" O.C. 16 GA STAPLE AT 4" O.C. 15 GA STAPLE AT 5" O.C. 14 GA STAPLE AT 6" O.C. 13 GA STAPLE AT 6" O.C. 13 GA STAPLE AT 5" O.C. 14 GA STAPLE AT 4" O.C. 15 GA STAPLE AT 3" O.C. 16 GA STAPLE AT 2.5" O.C. 15 GA STAPLE AT 2" O.C. 14 GA STAPLE AT 3" O.C. 13 GA STAPLE AT 4" O.C. 8d COMMON AT 3" O.C. MATERIAL: 7/16" SHEARWALL OR ROOF SHEATHING NOTES: 1. STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 716" INCH OUTSIDE DIMENSION. AND INSTALLED WITH CROWN PARALLEL TO THE LONG DIMENSION OF FRAMING MEMBER. 2. FRAMING SHALL BE 3x OR WIDER WHEN NAIL SPACING IS LESS THAN 3 INCHES ON CENTER. 3. ALL STAPLES SHALL HAVE 1 12" LONG LEGS MINIMUM. 4. STAPLE SIZES AND SPACING PER REPORT NO. ICC-ESR-1539 T11 ALTERNATE SHEATHING STAPLE OPTION TD32 NO SCALE CONNECTION TYPE JOIST OR TRUSS BEARING ON SILL OR GIRDER BRIDGING TO JOIST SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL TOP PLATE TO STUD DOUBLE STUDS, FACE NAIL DOUBLE TOP PLATES CONTINUOUS HEADER TO STUD CEILING JOISTS, LAPS OVER PARTITIONS CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL RAFTER OR TRUSS TO PLATE BUILT-UP CORNER STUDS TOENAIL (4)-8d COMMON (2 1/2" x 0.131") NAILING (3)-8d COMMON (2 1/2" x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES TOENAIL EACH END(2)-3"x 0.131" NAILS (Gun Nail) (2)-3"x 14 GAUGE STAPLES 16d (3 1/2"x 0.135") AT 16" O.C. FACE NAIL 3"x 14 GAUGE STAPLES AT 12" O.C. 3"x 0.131" NAILS (Gun Nail) AT 8" O.C. END NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES SOLE PLATE TO STUD END NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES FACE NAIL 16d (3 1/2"x 0.135") AT 24" O.C. 3"x 14 GAUGE STAPLES AT 8" O.C. 3"x 0.131" NAILS (Gun Nail) AT 8" O.C. FACE NAIL 16d (3 1/2"x 0.135") AT 16" O.C. 3"x 14 GAUGE STAPLES AT 12" O.C. 3"x 0.131" NAILS (Gun Nail) AT 12" O.C. DOUBLE TOP PLATES - FACE NAIL (8)-16d COMMON (3 1/2"x 0.162") (12)-3"x 0.131" NAILS (Gun Nail) (12)-3"x 14 GAUGE STAPLES LAP SPLICE RIM JOIST TO TOP PLATE 8d (2 1/2"x 0.131") AT 6" O.C. 3"x 14 GAUGE STAPLES AT 6" O.C. 3"x 0.131" NAILS (Gun Nail) AT 6" O.C. BLOCKING BETWEEN JOISTS OR RAFTERS TOENAIL (3)-8d COMMON (2 1/2"x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES AND TOP PLATE TOENAIL TOP PLATES, LAPS AND INTERSECTIONS FACE NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES CONTINUOUS HEADER, TWO PIECES 16d COMMON (3 1/2"x 0.162") FACE NAIL AT 16" O.C. ALONG EDGES CEILING JOISTS TO PLATE TOENAIL (3)-8d COMMON (2 1/2"x 0.131") (5)-3"x 0.131" NAILS (Gun Nail) (5)-3"x 14 GAUGE STAPLES FACE NAIL (3)-16d COMMON (3 1/2"x 0.162) (4)-3"x 0.131" NAILS (Gun Nail) (4)-3"x 14 GAUGE STAPLES (3)-16d COMMON (3 1/2"x 0.162) (4)-3"x 0.131" NAILS (Gun Nail) (4)-3"x 14 GAUGE STAPLES FACE NAIL (3)-8d COMMON (2 1/2"x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES TOENAIL TOENAIL 16d COM.(3 1/2"x 0.162") AT 24" O.C. 3"x 14 GAUGE STAPLES AT 16" O.C. 3"x 0.131" NAILS (Gun Nail) AT 16" O.C.FACE NAIL (2)-8d COMMON (2 1/2" x 0.131") USE- SIMPSON A35 AT 48" O.C.-NA- SIMPSON A35 AT EVERY OTHER BLOCK -NA- NOTE: A.MINIMUM NAILING SPECIFIED HEREIN SHALL BE PROVIDED UNLESS NOTED OTHERWISE ON PLANS, DETAILS OR GENERAL STRUCTURAL NOTES B. NAILING NOT NOTED ON THESE PLANS OR DETAILS SHALL BE PER I.B.C. TABLE 2304.10.1 T12 MINIMUM NAILING SCHEDULE - UNLESS NOTED OTHERWISE TD34 NO SCALE PR O FES S I O N A L ENGINEER STATEOF I D A HOA11 / 1 5 / 2 1 14 1 3 4 D VID B . P O R T ER L I C E NSED STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . AN Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER: CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com RMSDBPIF21-294 10" CONCRETE SLAB ON GRADE W/ #5 AT 12" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME FINISH FLOOR = 96'-7" CONCRETE SLAB ON GRADE T.O.W. 102'-0" 3' - 0 " 14 ' - 0 " 6'- 4 " 14 ' - 0 " 3' - 0 " 50 ' - 0 " 60'-0" 3' - 0 " 14 ' - 0 " 2' - 0 " 14 ' - 0 " 3' - 0 " 8"19'-4"20'-0"19'-4"8" 8"19'-4"20'-0"19'-4"8" WF18 / W1 W1 WF18 / W2 W1 WF18 / W1 W1 WF 1 8 / W 1 W1 WF 1 8 / W 2 WF 1 8 / W 2 WF 1 8 / W 1 W1 W1 W1 W1 WF18 / W2 F42 F78 4" CONCRETE SLAB ON GRADE W/ #3 AT 24" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME FINISH FLOOR = 100'-0" CONCRETE SLAB ON GRADE 10" CONCRETE SLAB ON GRADE W/ #5 AT 12" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME FINISH FLOOR = 96'-7" CONCRETE SLAB ON GRADE 40'-0"10'-0"10'-0" 40'-0"10'-0"10'-0" 40'-0"10'-0"10'-0" 4' - 6 " 11 ' - 0 " 3' - 6 " 12 ' - 0 " 3' - 6 " 11 ' - 0 " 4'- 6 " WF 1 8 / W 1 6' - 4 " 12 ' - 0 " WF 1 8 / W 1 F78 6" CONCRETE SLAB ON GRADE W/ #4 AT 18" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME FINISH FLOOR = 100'-0" CONCRETE SLAB ON GRADE F42 F42 F42 F78 F78 60° TYP 60° TYP F36 T.O.F. 96'-7" T.O.W. 102'-0" T.O.F. 96'-7" 105 101 104 OPP105 104 101 109 106 109 102 102 102 109 109 106 OPP 105 101 104 105101 104 109 107 106 109 109 106 109 102 103 101 102 T.O.W. 100'-0" T.O.F. 96'-7" 2 2 22 1 5 5 5 5 555 5 55 5 3'- 4 " 3 3 F36 103 2' - 0 " F36 103 1 60 ° TY P F36 1 103 F36 60 ° TY P 1 103 F30 F30 F30 F30 19 ' - 0 " 12 ' - 0 " 19 ' - 0 " 6'- 8 " 21 ' - 8 " 21 ' - 8 " 4" 3'-0" TYP 110 SCALE: FOUNDATION PLAN 1/4" = 1'-0" PR O FES S I O N A L ENGINEER STATEOF I D A HOA11 / 1 5 / 2 1 14 1 3 4 D VID B . P O R T ER L I C E NSED STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . AN Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER: CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com RMSDBPIF21-294 FOOTING SCHEDULE NOTES: 1. FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. 2. FOR MINIMUM CLEARANCE (CLR) OF REINFORCING, SEE GENERAL STRUCTURAL NOTES (GSN). MARK LENGTH WIDTH THICKN ESS FOOTING REINFORCING REMARKS F30 30" 30" 10"(3) #4 EACH WAY BOTTOM --- F36 36" 36" 10" (3) #4 EACH WAY TOP AND BOTTOM --- F42 42" 42" 10" (4) #4 EACH WAY TOP AND BOTTOM --- F78 78" 78" 12" (6) #5 EACH WAY TOP AND BOTTOM --- WF18 CONT 18" 10"(2) #4 CONT BOTTOM --- WALL (W) SCHEDULE MARK THICKNESS AND TYPE VERTICAL REINFORCING HORIZONTAL REINFORCING REMARKS W1 8" CONCRETE #4 AT 18" O.C. #4 AT 12" O.C. --- W2 6" CONCRETE #4 AT 18" O.C. #4 AT 18" O.C. --- SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 716" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 58"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 5 A. VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B. ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C. THE DEPTH OF FOOTING DIMENSION INDICATED IN THE G.S.N. IS A MINIMUM. FOUNDATION CONTRACTOR SHALL COORDINATE WITH THE SOILS REPORT AND OTHER TRADES TO INSURE THAT THESE MINIMUMS ARE SUFFICIENT FOR THE WORK. SEE TYPICAL DETAILS FOR ADDITIONAL REQUIREMENTS. D. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. E. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. F. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. G. W1, W2, ETC. - AS SHOWN ON PLAN INDICATES CONCRETE OR MASONRY WALLS. SEE WALL SCHEDULE FOR ADDITIONAL INFORMATION. H. WF18, WF24, ETC. - AS SHOWN ON PLAN INDICATES A CONTINUOUS WALL FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. I. F36, F48, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. J. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. K. VERIFY EXACT SIZE AND LOCATION OF DEPRESSED AND/OR RAISED SLABS WITH ARCHITECTURAL DRAWINGS. L. FOR SIDEWALK AND LANDING LOCATIONS, SEE ARCHITECTURAL DRAWINGS. M. COLUMN FOOTING SIZES ARE PRELIMINARY SIZES TO BE VERIFIED BY STRUCTURAL ENGINEER OF RECORD TO CONSTRUCTION. PRE-ENGINEERED BUILDING MANUFACTURER SHALL SUBMIT DESIGN CALCULATIONS PRIOR TO FABRICATING BUILDING COMPONENTS. CALCULATIONS SHALL SHOW ALL FOOTING LOAD PER METAL BUILDING MANUFACTURER'S ASSOCIATION "RECOMMENDED DESIGN PRACTICES MANUAL". FOUNDATION PLAN NOTES 56.7 1. (1) #4x12"-0" LONG (6"-0" EACH LEG) HAIRPIN 2. (1) #5x14"-0" LONG (7'-0" EACH LEG) HAIRPIN, BEND AS REQUIRED AND RUN PARALLEL TO THE SCALE PIT WALL 3. 18" DIAMETER SUMP PIT PLAN KEYNOTESX 19/32" APA RATED ROOF SHEATHING, BLOCK ALL PANEL EDGES, FASTEN W/ 10d COMMON NAILS AT 6" O.C. AT PANEL EDGES / BOUNDARY AND AT 12" O.C. IN THE FIELD. TYPICAL ROOF SHEATHING: 2 TYP 5 P1 B2 B2 B2 B2B2 WJ1 5 5 5 555 5 5 202 201 201 202 B1 5 B1 5 B1 B1 WJ2 WJ2 P1 P1 P1 1 1 11 19/32" APA RATED ROOF SHEATHING W/ 10d COMMON NAILS AT 6" O.C. AT PANEL EDGES / BOUNDARY AND AT 12" O.C. IN THE FIELD. TYPICAL ROOF SHEATHING: SCALE: ROOF FRAMING PLAN 1/4" = 1'-0" PR O FES S I O N A L ENGINEER STATEOF I D A HOA11 / 1 5 / 2 1 14 1 3 4 D VID B . P O R T ER L I C E NSED STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . AN Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER: CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com RMSDBPIF21-294 WOOD JOIST ( ) SCHEDULE MARK JOIST FACE MOUNT HANGER TOP FLANGE HANGER WJ1 1178" TJI 210 AT 16" O.C. IUS2.06/11.88 ITS2.06/11.88 WJ2 2x8 AT 16" O.C. --- --- WJ SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 716" APA RATEDSHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 58"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 5 ROOF FRAMING PLAN NOTES A. VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B. ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C. IF DOUBLE TOP PLATE IS NOTCHED, STEPPED OR BROKEN, PROVIDE A SIMPSON MSTC40 STRAP AT DISCONTINUITY. D. TYPICAL BEARING WALL FRAMING SHALL BE 2x6 STUDS AT 16" O.C. UNO. E. PROVIDE TRIMMER STUDS (TS) AND KING STUDS (KS) AT OPENINGS AS FOLLOWS, U.N.O.: OPENINGS 6'-0" OR LESS, (1) TS & (1) KS, OPENINGS 6'-1" TO 9'-0", (1) TS & (2) KS, 9'-1" TO 12'-0", (2) TS & (3) KS. FOR ATTACHMENT, SEE "TYPICAL HEADER CONNECTION" DETAIL. F. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. G. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. H. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. I. B1, B2, ETC. - AS SHOWN ON PLAN INDICATES A BEAM OR HEADER. SEE BEAM SCHEDULE FOR ADDITIONAL INFORMATION. J. WJ1, WJ2, ETC. - AS SHOWN ON PLAN INDICATES A JOIST. SEE JOIST SCHEDULE FOR ADDITIONAL INFORMATION. K. P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. L. TIE EACH ROOF JOIST AT BEARING LOCATIONS WITH (1) H2.5A CLIP, UNO. M. FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING CONDITION. N. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. 56.7 BEAM (B) SCHEDULE MARK SIZE B1 (2) 2x6 OR 4x6 OR (2) 134x512 LVL B2 (2) 2x10 OR 4x10 OR (2) 13 4x714 LVL 1. ATTACH BEAM TO POST W/ SIMPSON LCE4Z POST CAP 2. ATTACH JOISTS TOGETHER AT RIDGE, FIT TIGHT TOGETHER AND CONNECT WITH 1932"x714"x24" SHAPED PLYWOOD GUSSET ON BOTH SIDES, ATTACH GUSSET TO EACH JOIST W/ CONSTRUCTION ADHESIVE AND (24) 8d NAILS PLAN KEYNOTESX POST (P) SCHEDULE NOTES: 1. FOR CONNECTIONS AT EITHER END OF POST, SEE DETAILS. 2. UNO, SEE GENERAL STRUCTURAL NOTES (GSN) FOR LUMBER SPECIES AND GRADE. MARK SIZE SPECIES AND GRADE CONNECTION P1 4x4 DOUG FIR NO. 2 SEE TYPICAL DETAILS KEYNOTES: 1.PRE-ENGINEERED BUILDING 2.CONCRETE STEM WALL, SEE PLAN 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE SLAB ON GRADE, SEE PLAN 101 PRE-ENGINEERED BUILDING AT CONCRETE FOOTING NO SCALE 3" CLR 3" CL R 1 5 6 7 3 2 4 KEYNOTES: 1. PRE-ENGINEERED BUILDING BEYOND 2. CONCRETE STEM WALL, SEE PLAN 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7. CONCRETE SLAB ON GRADE, SEE PLAN 8. #4 BENT DOWEL AT 18" O.C. 102 PRE-ENGINEERED BUILDING AT CONCRETE FOOTING CS_MB102 NO SCALE 3" CLR 3" CL R 1 5 6 7 8 3 2 3 4 18" 18" 103 PRE-ENGINEERED COLUMN AT CONCRETE FOOTING NO SCALE KEYNOTES: 1.PRE-ENGINEERED COLUMN, SEE PLAN 2. ANCHOR BOLTS W/ NUT AT BOTTOM 3. SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4. MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING & CONCRETE STEM WALL BEYOND CONT REINFORCING THROUGH PIER (NOT SHOWN FOR CLARITY) 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE FOOTING, SEE PLAN 8.CONCRETE PIER W/ (6) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 9.CONCRETE SLAB ON GRADE, SEE PLAN 10.HAIRPIN AS OCCURS, SEE PLAN 3" CLR 3" CL R 3" MIN 7 6 10 3 1 2 8 9 4 5 KEYNOTES: 1. PRE-ENGINEERED COLUMN, SEE PLAN 2.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3.CONCRETE STEM WALL BEYOND, CONT REINFORCEMENT TROUGH PIER (NOT SHOWN FOR CLARITY) 4.MINIMUM FOOTING DEPTH, SEE GSN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 6.CONCRETE FOOTING, SEE PLAN 7.18"Ø CONCRETE PIER W/ (8) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 8. CONCRETE GRADE BEAM, SEE PLAN 9. HAIRPIN AS OCCURS, SEE PLAN 10.CONCRETE SLAB ON GRADE, SEE PLAN 11.ANCHOR BOLTS W/ NUT AT BOTTOM 104 PRE-ENGINEERED COLUMN AT CONCRETE FOOTING NO SCALE 5 3 10 9 7 8 4 1 11 6 2 3" CLR 3" CL R KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2. CONT 2x PT SOLE PLATE W/ ANCHOR BOLTS PER SHEARWALL SCHEDULE 3.CONCRETE SLAB ON GRADE, SEE PLAN 4. CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.MINIMUM FOOTING DEPTH, SEE GSN 8. WALL SHEATHING AS OCCURS, SEE PLAN 9. EDGE NAILING, SEE SHEARWALL SCHEDULE NOTES: A.WATERPROOF ANY EXTERIOR WOOD FRAMING WITHIN 8" OF GRADE PER ARCH DRAWINGS 106 WOOD STUD WALL AT FOUNDATION NO SCALE 3" CLR 3" CL R 8 7 9 6 1 2 5 4 3 KEYNOTES: 1.WALL BEYOND, SEE PLAN 2.#4 BENT DOWEL AT 18" O.C. 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6. COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.MINIMUM FOOTING DEPTH, SEE GSN 8.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 18" 18" 107 CONCRFETE SLAB AT FOUNDATION NO SCALE 3" CLR 3" CL R 7 6 5 4 3 1 2 109 CONCRETE SLAB AT FOUNDATION NO SCALE 3" CLR 3" CL R 5 4 3 1 2 KEYNOTES: 1. WALL BEYOND, SEE PLAN 2.#4 BENT DOWEL AT 18" O.C. 3. CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 18" 18" KEYNOTES: 1.WOOD JOIST W/ (2) 16d NAILS, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4. WALL SHEATHING AS OCCURS, SEE PLAN 5.EDGE NAILING, SEE SHEARWALL SCHEDULE 6. CONT RIM BOARD 7.BOUNDARY NAILING, SEE PLAN 8.ROOF SHEATHING, SEE PLAN 201 WOOD JOIST AT WOOD STUD WALL NO SCALE 1 2 3 55 4 7 6 8 5 KEYNOTES: 1. WOOD JOIST, SEE PLAN 2. WOOD JOIST BLOCKING AT 24" O.C. W/ (2) 16d NAILS 3. CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 4.WOOD STUD WALL, SEE PLAN 5.WALL SHEATHING AS OCCURS, SEE PLAN 6.EDGE NAILING, SEE SHEARWALL SCHEDULE 7. CONT RIM BOARD 8.BOUNDARY NAILING, SEE PLAN 9. ROOF SHEATHING, SEE PLAN 10.(4) 10d NAILS INTO EACH BLOCK 202 WOOD JOIST AT WOOD STUD WALL NO SCALE 1 3 4 66 5 8 7 9 2 10 6 KEYNOTES: 1. PRE-ENGINEERED COLUMN, SEE PLAN 2. SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3. CONCRETE STEM WALL BEYOND, CONT REINFORCEMENT TROUGH PIER (NOT SHOWN FOR CLARITY) 4. MINIMUM FOOTING DEPTH, SEE GSN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 6.CONCRETE FOOTING, SEE PLAN 7.18"Ø CONCRETE PIER W/ (8) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 8.CONCRETE GRADE BEAM, SEE PLAN 9. ANCHOR BOLTS W/ NUT AT BOTTOM 10. CONCRETE SLAB ON GRADE, SEE PLAN 105 PRE-ENGINEERED COLUMN AT CONCRETE FOOTING NO SCALE 5 3 10 7 8 4 1 9 6 2 3" CLR 3" CL R 3 3 3 KEYNOTES: 1. WOOD POST, SEE PLAN 2. (4) #4 BARS VERTICAL 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.#3 TIES AT AT 8" O.C. 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7. MINIMUM FOOTING DEPTH, SEE GSN 8.8"Ø OR SQR CONCRETE PIER, SEE PLAN 9.SIMPSON PBS44 POST BASE NOTES: A.WATERPROOF ANY EXTERIOR WOOD FRAMING WITHIN 8" OF GRADE PER ARCH DRAWINGS 110 WOOD POST AT FOUNDATION NO SCALE 75 3" CL R 1 3" CLR 2 6 8 4 112" CLR 8" MI N 33 9 8" PR O FES S I O N A L ENGINEER STATEOF I D A HOA11 / 1 5 / 2 1 14 1 3 4 D VID B . P O R T ER L I C E NSED STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . AN Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER: CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com RMSDBPIF21-294 F: \ 2 1 \ 2 1 0 5 7 M a d i s o n C o u n t y T r a n s f e r S t a t i o n \ 2 1 0 5 7 M a d i s o n T r a n s f e r . d w g N o v 1 7 , 2 0 2 1 - 2 : 2 6 p m Engineered Systems Associates Nov 16, 2021 C- PLAN NOTES: 1 A-THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONNECTIONS ON THE JOB SITE. ALL WORK SHALL BE EXECUTED FROM MEASUREMENTS TAKEN AT THE SITE. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE TO INSURE PROPER CODE CLEARANCES FOR ELECTRICAL AND MECHANICAL ACCESS WHEN INSTALLING ANY EQUIPMENT SUPPLIED BY THE MECHANICAL CONTRACTOR. IT IS CRITICAL THAT THIS CONTRACTOR COORDINATE EQUIPMENT LOCATIONS WITH PIPING, DUCTWORK, ELECTRICAL CONDUIT AND BUILDING STRUCTURE TO INSURE CODE COMPLIANCE. B- GENERAL NOTES: SEE SITE PLAN FOR CONTINUATION. RAISE 3/4" CW IN THIS LOCATION WITH BALL VALVE. ROUTE REFRIGERATION LINES AS HIGH AS POSSIBLE. SEE DETAIL F-MP2.0. RUN 3/4" CONDENSATE DRAIN UNDER SLAB TO NEW PIT. SEE TYPICAL WATER HEATER DETAIL A-MP2.0. SEE PIPING IN OUTSIDE WALL DETAIL D-MP2.0. SEE DETAIL H-MP2.0. NO VENTING REQUIRED FOR A BALANCED AIR ENVIRONMENT SAND AND GREASE INTERCEPTOR UNLESS REQUIRED BY LOCAL AHJ. WATER LINE UNDER SLAB TO BE CONTINUOUS SOFT COPPER WITH NO ELBOWS OR JOINTS. TRENCH DRAIN TO BE INSTALLED IN NEW PIT. SEE DETAIL J ON THIS SHEET. SEE ARCHITECTURAL DRAWINGS FOR PIT DETAILS. SOME PIPING ROUTES AS SHOWN ON PLANS FOR CLARITY. FIELD VERIFY BEST POSSIBLE ROUTES. RUN FLUE EXPOSED TO METAL ROOF. SEE DETAIL G-MP2.0. RUN 6"Ø EA DUCT UP TO METAL ROOF WITHIN 2' OF ROOF PEAK. SEE DETAIL ON THIS SHEET. 2 3 ELECTRONIC THERMOSTAT EQUIPMENT SYMBOLFC 1 T INSULATED FLEXIBLE DUCT CEILING DIFFUSER ROUND BRANCH DUCT WITH HAND DAMPER HAND DAMPERHD MECHANICAL LEGEND DESCRIPTIONSYMBOL ROOF MOUNTED UPBLAST EXHAUST GRILLE RETURN AIR OR EXHAUST FAN 4 5 6 7 SCALE: 1/4" = 1'-0" MECHANICAL FLOOR PLAN NORTH 5' MIN750 GALLON PRE-FABBED GREASE INTERCEPTOR WITH INTERNAL FLOW CONTROL AND BALANCED AIR ENVIRONMENT. SEE DETAILS ON SHEET MP2.0. GW GW GW GW GW 1 CO SYMBOL CLEANOUT PLUMBING LEGEND VENT LINE PIPING CONDENSATE DRAIN PIPING HOT WATER RECIRC. PIPING ROOF DRAIN PIPING BALL TYPE ISOLATION VALVE PIPE RISE PIPE DROP VTR COTG VENTV WCO CLEANOUT TO GRADE WALL CLEANOUT VENT THRU ROOF DESCRIPTION GAS PIPINGG SOIL OR WASTE PIPING DOMESTIC COLD WATER PIPING DOMESTIC HOT WATER PIPING CD RDL ROOF OVERFLOW DRAIN PIPINGRDO TD-1 TD-1 1 4" COTG 98' 6" INVERT HB-1 4"4"2" FD-1 WC-1 WH-1 1 1" 4" 4" COTG 4" COTG 4" 4" 2 CU 1 4 FC 23 S S S S S S SLLLLLL INVERT ELEV. 95' 7" INVERT ELEV. 95' 7" 4" COTG 94' 7" INVERT T 5/8" 3/4" 6 EH 1 7 7 8 8 8 4" COTG TRENCH SECTIONS TRENCH NO. * SHALLOW INVERT 'A' DEEP INV. 'B' * TRENCH SECTIONS ARE 80" LONG. DO NOT USE NEUTRAL SECTIONS. 52 ' - 0 " T R E N C H 8610 8.90" 9.50" 86011 9.50" 10.10" 8604 5.30" 5.90" 8605 5.90" 6.50" 8606 6.50" 7.10" 8607 7.10 7.70" 8608 7.70" 8.30" 8609 8.30" 8.90" PLUMBING CONTRACTOR IS RESPONSIBLE FOR CONCRETE ENCASEMENT AND REINFORCING. EXTEND 4" WASTE LINE FROM END OF TRENCH AND CONNECT TO SAND AND GREASE TRAP AS SHOWN ON PLANS. PROVIDE FLOOR CLEAN OUT ON WASTE LINE 'A ' D E P T H 'B ' D E P T H 52'-0" 50'-11" INVERT 4" 1-1/4" 4"4" 6-1/4" TRENCH DRAIN INSTALLATION DETAILS NO SCALEJ 9 9 10 11 1" RC-1EF 1 11 4" VTR10 FD-1 S-1 L-1 1/2" 5/8" T EH 1 FC 13 1" EH 2 CEILING ESCUTCHEON CEILING FLOOR RUN BELOW TRUSSES BALL VALVE (TYP) TYPICAL UNION SUPPLY TO BUILDING DOUBLE CHECK VALVE BACKFLOW PREVENTER WITH BALL VALVES AND STRAINER 3/4" HOSE THREAD FITTING NO SCALE VERTICAL WATER PRESSURE REDUCING STATIONK COMBINATION PRESSURE REDUCING VALVE AND STRAINER. SET DISCHARGE AT 60 PSIG PRESSURE GAGE 0 - 100 PSI RANGE WATER SUPPLY TO BUILDING PRV 12 12 FIXTURE SCHEDULE ADA TANK TYPE WATER CLOSET - KOHLER K-3999 "HIGHLINE" W/ ELONGATED BOWL, K-4670-C WHITE OPEN FRONT SEAT, BOLT CAPS AND 1/2" STOP VALVE. VENTWASTE --- HOT COLDSYM.DESCRIPTION WC-1 4"2"1/2" L-1 1-1/2"1-1/2"1/2"1/2" FD-1 2" 2"------2" FLOOR DRAIN - ZURN Z-415 WITH 5"Ø NICKEL-BRONZE STRAINER AND 2" DEEP SEAL P-TRAP, ZURN 1022 TRAP PRIMER. ADA WALL HUNG LAVATORY - KOHLER K-2032 "GREENWICH" WITH WALL CARRIER, MOEN L4600 LEVER HANDLE FAUCET, K-7715 OPEN GRID STRAINER WITH OFFSET WASTE LINE, 1/2" STOPS AND 1-1/4" P-TRAP. PROVIDE INSULATING JACKET ON HW AND WASTE PIPING. ---HB-1 3/4"--- --- --- --- 4" ---TRENCH DRAIN - ZURN 886-HD 6-3/4" WIDE HEAVY DUTY TRENCH DRAIN SYSTEM WITH 4" END OUTLET, END CAP AND DUCTILE IRON SLOTTED GRATE, LENGTH AS PER FLOOR PLAN. TD-1 SINGLE COMPARTMENT SINK - ELKAY MODEL PSR1918 WITH 18 GA TYPE 304 STAINLESS STEEL CONSTRUCTION, 1-HOLE FAUCET DRILLINGS, ELKAY LK1000CR FAUCET, LK-99 STRAINER, 1-1/2" P-TRAP AND 1/2" BALL TYPE STOP VALVES. 1-1/2"1-1/2"1/2"1/2"S-1 WATER HEATER PIPING DETAIL NO SCALE R 3/4" WATER HEATER ANCHOR COLD WATER LINE HOT WATER LINE DIELECTRIC UNION (TYP) HEAT TRAP FITTING MTHERMOMETER DRAIN VALVE W/ THREADED HOSE CONNECTION PIPE FULL SIZE TO FLOOR DRAIN T&P RELIEF VALVE SIZED TO MATCH WATER HEATER AMTROL ST-5 EXPANSION TANK ELECTRIC WATER HEATER MIXING VALVE FOR TEMPERED WATER A SUCTION REFRIGERANT PIPING LIQUID MITSUBISHI ELECTRIC M-SERIES MODEL MXZ-3C24NA2. SEER 20 REMARKSMCAEATBTUSYM.CHAR. 22.195°FCU 1 24,000 280/60/1 CONDENSING UNIT SCHEDULE 140# WEIGHT 3/8"1/4" REMARKS FAN COIL SCHEDULE FC 1 240 22# SYM.CFM WEIGHT MITSUBISHI M-SERIES MSZ-GL12NA WITH OPTIONAL WALL MOUNTED THERMOSTAT. FAN 30 MCA 1 WATTS CONDENSATE DRAIN 5/8" COOLING & HEATING CAPACITY 12,000 BTU CHAR. 208/60/1 FLOOR DRAIN IN CONCRETE FLOOR 2" WASTE LINE TO WASTE AND VENT NO SCALE SYSTEM 2" DEEP SEAL P-TRAP TO FINISH FLOOR LEVEL STRAINER ADJUST FLOOR DRAIN BODY TILE AND GROUT CONCRETE FLOOR B PEX PIPE FITTING DETAILS NO SCALE POLYMER, COPPER, BRONZE OR BRASS FITTING PEX PIPING AS SHOWN ON PLANS REINFORCED RING THIS TYPE (COLD EXPANSION) OF FITTING REQUIRES THAT THE PEX PIPING, WITH REINFORCING PEX RING PLACED OVER THE END OF THE END OF THE PIPE, IS EXPANDED BEFORE THE FITTING IS INSERTED INTO THE PIPE END. THE EXPANDED PIPE END IS ALLOWED TO RETRACT ONTO THE FITTING TO FORM THE SEAL. THE MEMORY OF THE PIPE ALLOWS IT TO TIGHTEN OVER THE FITTING. AN EXPANDER TOOL IS REQUIRED TO EXPAND THE PIPE AND THE PEX RING TOGETHER. NOTE: STAINLESS STEEL CAMP BANDS ARE ALSO PERMITTED FOR REINFORCING RING. ALL JOINTS (TEES. ELBOWS, COUPLINGS, ETC.) ARE JOINTED SIMILARLY. 12" 6"HEAT SOURCE PEX PIPING MIN. CLEARANCES KEEP TUBING A MINIMUM OF 12" VERTICALLY OR 6" HORIZONTALLY FROM SOURCES OF HIGH HEAT SUCH AS LIGHT FIXTURES, FLUES OR HEATING EQUIPMENT. PEX PIPE HANDLING DETAILS NO SCALE NOTE: USE ONLY CONTINUOUS LENGTH TUBING (NO FITTINGS) WHEN INSTALLING PEX UNDER OR WITHIN A SLAB. PROTECT PEX TUBING WITH NONMETALLIC SLEEVES WHERE IT PENETRATES A SLAB OR FOUNDATION WALL. DO NOT CRUSH OR KINK TUBING DO NOTE DRAG TUBING OVER ROUGH TERRAIN, ROCKS, OR ANY SURFACE THAT CAN CUT, PUNCTURE OR DAMAGE TUBING WALL. 3/8" 4" 1/2" 5" 3/4" 7" 1" 9" TUBING SIZE MIN. RADIUS BENDING TUBING AND FITTINGS SHALL BE STORED UNDERCOVER FOR CLEANLINESS AND TO AVOID EXPOSURE TO SUNLIGHT. CONSULT MANUFACTURER FOR RECOMMENDED LIMITS TO OUTSIDE STORAGE. NATIVE SOIL 6" MIN. BASE CRUSHED & WELL- PACKED AGGREGATE MATERIAL APPROXIMATELY 3/4" SIZE ROCK CA-07CLASS 1A CONCRETE PAD BY GENERAL CONTRACTORS 72" MAX HEIGHT SIDE VIEW SEE MANUFACTURE RECOMMENDED INSTALL DETAILS. CRUSHED AGGREGATE MATERIAL APPROXIMATELY 3/4" SIZE ROCK, CA-7 CLASS 1A FLOW RISERS TO GRADE IF REQUIRED FLOW 2-WAY CLEANOUT TEE (414155BC) 2-WAY CLEANOUT TEE (414155BC) STANDARD 4" MECHANICAL JOINT COUPLING NO SCALE PRE-FABBED TRAFFIC RATED 750 GAL GREASE INTERCEPTOR DETAIL SIDE VIEW OPTIONAL OUTLET MANUFACTURE TRAFFIC RATED COVERS NOTES: 1) GREASE INTERCEPTOR AS SPECIFIED TO BE RATED FOR AND SUPPLIED WITH AN INTERNAL FLOW CONTROL SYSTEM AND A BALANCED AIR ENVIROMENT. NO VENTING REQUIRED UNLESS MANDATED BY AHJ. 2) GREASE INTERCEPTOR AS SPECIFIED TO HAVE A BUILT-IN SAMPLING PORT. NO EXTERNAL SAMPLING PORT REQUIRED UNLESS MANDATED BY AHJ. 3) WIDTH AND LENGTH OF EXCAVATION SHALL BE MIN OF 12" OR GREATER THAN THE TANK DIMENSIONS ON ALL SIDES. 4) DEPTH OF EXCAVATION SHALL BE AT LEAST 6" DEEPER THAN TANK BOTTOM. 5) STABILIZE AND COMPACT SUB GRADE TO 95% PROCTOR 6) FILL TANK WITH WATER TO DISCHARGE LEVEL TO PREVENT MOVEMENT DURING BACKFILLING PROCESS AND TO RESIST BACKFILL LOAD. 7) BEFORE BACKFILLING AND POURING OF SLAB INSTALL RISERS AS REQUIRED AND COVER ASSEMBLY TO SUIT FINISHED FLOOR/GRADE LEVEL. 14" MIN WITH NO RISER F: \ 2 1 \ 2 1 0 5 7 M a d i s o n C o u n t y T r a n s f e r S t a t i o n \ 2 1 0 5 7 M a d i s o n T r a n s f e r . d w g N o v 1 7 , 2 0 2 1 - 2 : 2 6 p m Engineered Systems Associates Nov 16, 2021 C E H 3/4"3/4" --- ---WH-1 GAS WATER HEATER- A.O. SMITH SIGNATURE MODEL 100 40 GALLON HEATER, AMTROL ST-5 EXPANSION TANK, T&P VALVE. WITH DUAL 3.8KW COPPER HEATING ELEMENTS. SEE DETAIL THIS SHEET. WH-1 EH 1 WALL MOUNTED 6824 2 208/60/1 INTEGRAL T-STAT QMARK TYPE CRA2028-IF COMPLETE WITH SURFACE MOUNTING FRAME. ELECTRIC HEATER SCHEDULE SYM.TYPE BTU KW CHAR CONTROL REMARKS EH 2 WALL MOUNTED 3412 1 208/60/1 INTEGRAL T-STAT QMARK TYPE CRA2028-IF COMPLETE WITH SURFACE MOUNTING FRAME. MOCP 25 INSULATION SEAL WALL PENETRATIONS BUILDING WALL WATER TIGHT. "CUSH-A-CLAMP" OR EQUAL. SECURE REFRIGERANT PIPING TO SUPPORTS WITH "HYDRA-ZORB" REFRIGERANT PIPING SUPPORT AT WALL SUCTION LINES SHOWN. LIQUID LINE SIMILAR. OF SUCTION LINE 6" x 4" x 1/4" ANCHORED TO STRUCTURE WITH 1/2" x 5-1/2" EXPANSION BOLTS NO SCALE 1-5/8" P-3300 ASSEMBLY. AGAINST CLAMP EQUAL. WELD "UNISTRUT" OR BOTH SIDES (TYP). SLOPED TOP 26 GA. PRE-FINISHED SHEET METAL CAULK ALL AROUND WEATHERTIGHT COVER. COLOR TO BE SELECTED BY THE ENGINEER. BUTT INSULATION METAL COVER 18 GA. GALV. NOTE: BRICK COLOR (TYP). PAINT ANGLE SUPPORTS TO MATCH BLDG. FACE REFRIGERANT PIPE SUPPORT DETAIL CEILING JOIST ROOF OR PIPING TO SUPPORTS SECURE REFRIGERANT CLAMP ASSEMBLY SUCTION LINE THRU RUN INSULATION OF CLAMP OR EQUAL WITH "UNISTRUT" SUCTION LINES TYPICAL REFRIGERANT PIPE IN MECH. ROOM NO SCALE HANGER RODS OR EQUAL (TYPICAL) "UNISTRUT" CHANNEL 1-5/8" P-1001 INSULATION ON ALL PIPING SUPPORTS OF JOISTS. NO PIPING SUPPORTS ARE TO BE PRIOR TO FIREPROOFING FIREPROOFING HAS BEEN DONE. ARE TO BE INSTALLED ATTACHED AFTER NOTE: 1" CHANNEL (UNISTRUT OR FEE & MASON) WELD TO JOISTS F I PATTERN REMARKSFIRE DAMPERFINISHCONSTR.CFM RANGESIZE THROW GRILLE AND REGISTER SCHEDULE SYM.TYPE RC-1 NAALUM125CAP ROOF INSECT SCREEN & BACK-DRAFT DAMPER TWIN CITY MODEL 634M WITH ALUMNA WHITE EXHAUST FAN SCHEDULE REMARKSR.P.M.WATTS CHAR.CONTROLC.F.M.TYPE S.P.E.SYM. CEILING MOUNTED 120 TWIN CITY T150 WITH BACKDRAFT DAMPER & INSECT SCREEN.25 100 120/60/1 7501 EF SEE ELEC. VENT THRU METAL ROOF DETAIL PANEL METAL ROOF BASE CORROSION RESISTANT AROUND PERIPHERY SEALANT UNDER AND BETWEEN TRUSSES FROM CEILING THRU ROOF GALVANIZED STEEL PIPE FLASHINGS SHALL BE "BUILDEX DEKTITE" OR APPROVED FASTENERS EQUAL AS REQUIRED BY MANUFACTURER. NO SCALE CLAMP STACK TO UNISTRUT NOTE: OF BASE ATTACH UNISTRUT STACK SELF-DRILLING PANEL METAL ROOF TO PIPE SIZE RUBBER CONE CUT ALUMINUM BASE ROOF PLAN OF BASE G HOSE BIBB - ZURN MODEL Z1305 "ECOLOTROL" ENCASED NON-FREEZE, LENGTH TO SUIT WALL THICKNESS. FC 2 240 22#30 1 5/8"12,000 BTU208/60/1 MITSUBISHI M-SERIES MSZ-GL12NA WITH OPTIONAL WALL MOUNTED THERMOSTAT. MMP TEP P.E. JOB #2189 Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 RE X B U R G , MA D I S O N C O U N T Y TR A N S F E R S T A T I O N S C A L E S ID A H O 867 NOV. '21 DUPLEX RECEPTACLE WALL MOUNTED FIXTURE CEILING MOUNTED FIXTURE FLUORESCENT FIXTURE ELECTRICAL SYMBOL SCHEDULE BRANCH CIRCUIT - HOME-RUN TO PANEL BRANCH CIRCUIT - IN FLOOR OR UNDERGROUND MECHANICAL EQUIPMENT OR DETAIL SYMBOL DRAWING NOTE (ON THE SHEET WHERE SHOWN) THERMOSTAT W/ 3/4"CONDUIT W/PULL CORD TO MECH. UNIT FAN MOTOR CONNECTION POINT BRANCH CIRCUIT - CONCEALED * SEE MECHANICAL DRAWINGS FOR CONDUIT DESTINATION AND M.C. V.I.F. A.F.F. B.F.G. NL E.C. ABOVE FINISHED FLOOR BELOW FINISHED GRADE VERIFY IN FIELD NIGHT LIGHT (CONNECT TO UNSWITCHED LEG OF LTG CIRCUIT) MECHANICAL CONTRACTOR ELECTRICAL CONTRACTOR MOTOR CONNECTION POINT T EF TELEPHONE / DATA BOARD (GRND AS PER UTIL. CO) TIME CLOCK SWITCHT 1 1 A-1,3 DOUBLE DUPLEX OUTLET (4-PLEX) JUNCTION BOX BRANCH PANELBOARD J EMERGENCY WALL LIGHT WITH 90MIN. BATTERY PHOTOELECTRIC CELL/SWITCH HVAC SYSTEM SENSOR - SEE MECHANICAL E S WALL BOX DIMMER SWITCH. (SWITCH TO BE COMPAT. W/LOAD SERVED) SINGLE POLE SWITCH (SEE SUBSCRIPTS) RECESSED CAN FIXTURE MAIN/DISTRIBUTION PANELBOARD TRAC LIGHT SYSTEM * * PUSHBUTTON (AS INDICATED ON DRAWINGS) ROUGH-IN BOX MUD RING ORIENTATION. RECPT. SUB- SCRIPTS AC=ABOVE COUNTER GFI=GROUND-FAULT IG=ISOLATED GROUND S=SURGE SUPPRESSION TR=UL TAMPER RESISTANT WP=WEATHERPROOF COVER W/GFCI RECEPT. TV= RECPT. FOR TV, SEE ARCH. ELEVATION DWGS FOR MTG. HEIGHT USB=RECEPTACLE W/USB CHARGER CR=CORD REEL (SEE DETAIL) F=FUSED DISCONNECT (FUSE PER EQUIP. NAMEPLATE) DISCONNECT SWITCH (SIZE AND TYPE AS INDICATED) B=ENCLOSED CIRCUIT BREAKER CEILING MOUNTED DUPLEX RECEPTACLE FLOORBOX - POWER ONLY (2-DUPLEX RECEPTACLES) DUAL-LEVEL SWITCHES; IN-BOARD AND OUT-BOARD LAMPS SHALL BE SWITCHED SEPARATELY. (SUBSCRIPT APPLIES TO BOTH SWITCHES) SWITCH SUB- SCRIPTS 3 = 3-WAY 4 = 4-WAY F = EXHAUST FAN TIMER (INTERMATIC MODEL EI400 SERIES) T = THERMAL OVERLOAD SWITCH W/PILOT LIGHT P = 1-POLE SWITCH WITH PILOT LIGHT. (SEE SPECS) M = SWITCH SUPPLIED W/ EQUIPMENT (INSTALLED BY E.C.) WP = WEATHERPROOF CEILING MOUNTED OCCUPANCY SENSOR BLANK = DUAL TECH., LINE VOLTAGE [WATTSTOPPER #DT-355] L = LARGE AREA, ULTRASONIC LOW VOLTAGE [WATTSTOPPER #WT-2205] H = HALLWAY, ULTRASONIC LOW VOLTAGE [WATTSTOPPER #WT-2255] R = RESTROOM, DUAL TECH., LINE VOLTAGE, 2-POLE [SENSOR SWITCH #CMR-PDT-9-2P], (1) RELAY FOR LTG, (1) RELAY FOR EXHAUST FAN (30 MIN. DELAY) D = INTEGRAL DAYLIGHT SENSOR TO AUTOMATICALLY CONTROL FIXTURES IN DAYLIGHT ZONES H = WALL OCC. SENSOR ON/OFF/DIM W = WALL MOUNTED ON/OFF/DIM OCCUPANCY SENSOR *PROVIDE LOW VOLTAGE SENSORS WITH POWER/RELAY PACK(S) AS REQUIRED FOR OPERATION. [WATTSTOPPER #BZ-50] EXIT SIGN, WALL OR CEILING MOUNT & DIRECTIONAL ARROWS AS INDICATED ON DRAWINGS. CONNECT TO UNSWITCHED LEG OF NEAREST LIGHTING CIRCUIT. EMERG. FIXTURE WITH EMERG. BATTERY PACK, CONNECTED TO UNSWITCHED LEG OF LIGHTING CIRCUIT. G.C.GENERAL CONTRACTOR N.T.S.NOT TO SCALE V=VFD (PROVIDED BY M.C. CONNECTED AND INSTALLED BY E.C.) COMBINATION STARTER & FUSED DISCONNECT SWITCH; 2-SETS OF NO/NC CONTACTS, CONTROL XFMR, FUSE PER EQUIP. NAMEPLATE CROSS LINES SHOW # OF PHASE/NEUTRAL CONDUCTORS IF MORE THAN TWO. EQUIPMENT/ISOLATED GROUNDING CONDUCTORS ARE NOT SHOWN. PROVIDE 'GREEN' EQUIP. GROUNDING CONDUCTOR FOR ALL CIRCUITS AND ADDITIONAL ISOLATED GROUND WHERE INDICATED. F M LED 0-10V: LEVITON RENOIR II #AWSMG-7D* W/MATCHING WALL PLATE OR EQUAL (* COLOR TO MATCH WIRING DEVICES)S SS S F#E NIGHT LIGHT FIXTURE, CONNECTED FIXTURE TO UNSWITCHED LEG OF LIGHTING CIRCUIT.NL SP SWITCH MOUNTED OCCUPANCY SENSOR, LINE VOLTAGE, W/ COVERPLATE, (COLOR TO MATCH WIRING DEVICES) P = PASSIVE INFRARED,1-POLE [WATTSTOPPER # PW-301] P2 = PASSIVE INFRARED,2-POLE [WATTSTOPPER # PW-302] D = DUAL TECHNOLOGY,1-POLE [WATTSTOPPER # DSW-100] D2 = DUAL TECHNOLOGY,2-POLE [WATTSTOPPER # DSW-200] S DATA/COMM. SYMBOL SCHEDULE TELEPHONE OUTLET ( _=# OF CABLES, X=CONDUIT SIZE SEE BELOW) DATA OUTLET ( _=# OF CABLES, X=CONDUIT SIZE SEE BELOW) TELE/DATA OUTLET ( _=# OF CABLES, X=CONDUIT SIZE SEE BELOW) _T-X _D-X _T/_D-X TELEPHONE & DATA OUTLET NOTES: 1. UTILIZE 4 11/16" DEEP BOX WITH REQUIRED MUDRING AND CONDUIT TO IT ROOM, TERMINATE WITH INSULATED THROAT BUSHING. PROVIDE QTY OF CABLES INDICATED FROM OUTLET TO NEAREST TELE/DATA ROOM. SEE DWGS FOR ADDITIONAL INFORMATION. PROVIDE J-HOOKS 3FT ON CENTER ABOVE ACCESSIBLE CEILING FOR SUPPORT OF CABLING. 2. CONDUIT SIZES (X): 2=1/2", 3=3/4" & 4=1", 5=1 14" OR (2) 1" 3. NO LABEL INDICATES: 4 11/16" DEEP BOX WITH 1-GANG MUDRING AND 1" CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING/CABLE TRAY. TERMINATE WITH INSULATED THROATBUSHING (UNO). PROVIDE WITH PULL STRING. DATA OUTLET - ABOVE CEILING ( _=# OF CABLES)_D CEILING MOUNTED SPEAKER AND BACKBOX T.V. OUTLET (C = CEILING MOUNTED) UTILIZE 4 11/16" DEEP BOX WITH 1-GANG MUDRING AND 34" CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING/CABLE TRAY, TERMINATE WITH INSULATED THROAT BUSHING. INSTALL CONNECTOR AND FACEPLATE AND PROVIDE COAXIAL CABLE FROM OUTLET TO NEAREST TV SYSTEM AMPLIFIER. PROVIDE J-HOOKS 3FT ON CENTER ABOVE ACCESSIBLE CEILING FOR SUPPORT OF CABLING. V VOLUME CONTROLLER COMMUNICATIONS CABLING REQUIREMENTS: (SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION) NETWORK CABLING - CAT6 PLENUM RATED, BLUE TELEPHONE CABLING - CAT6 PLENUM RATED, YELLOW TELEVISION CABLING - COAXIAL, RG-6 1. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL LAMP TYPES WITH FIXTURE TYPE BEFORE ORDERING. 2. ELECTRICAL CONTRACTOR SHALL REFER TO THE MECHANICAL DRAWINGS FOR EXACT LOCATION OF ALL MECHANICAL EQUIPMENT AND ELECTRICAL CONNECTIONS. 3. ELECTRICAL CONTRACTOR SHALL PROVIDE MINIMUM WORKING CLEARANCE AS PER NEC BEFORE INSTALLING ANY ELECTRICAL PANELS FOR CABINETS. 4. INSTALL ALL LIGHT FIXTURES IN MECHANICAL ROOM AFTER THE MECHANICAL EQUIPMENT IS IN PLACE, ADJUST AS NECESSARY. PROVIDE CHAIN SUSPENSION KITS AS REQUIRED. 5. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT FIXTURE LOCATIONS, CEILING TYPES, ETC. 6. CONFIRM EXACT LOCATIONS OF ALL TELEPHONE / DATA OUTLETS WITH OWNER PRIOR TO ROUGH - IN. 7. ELECTRICAL CONTRACTOR SHALL MOUNT SWITCHES AT 48" AND MOUNT CONVENIENCE OUTLETS AT 18" OR AS SHOWN ON PLANS TO MEET HANDICAPPED REQUIREMENTS. 8. LOCATE SWITCHES, OUTLETS, ETC., SHOWN AT ROOM ENTRY DOORWAYS, AS CLOSE TO DOOR FRAME AS POSSIBLE, SO AS NOT TO INTERFERE WITH ROOM CABINETS, ETC. 9. SUPPORT ALL LIGHT FIXTURES INDEPENDENT OF CEILING. 10. ELECTRICAL CONTRACTOR SHALL OBTAIN ALL APPLICABLE PERMITS FOR THIS WORK AND PAY ASSOCIATED FEES. 11. MAINTAIN 24" MIN. CLEARANCE FROM ALL COMMUNICATIONS CABLES AND ELECTRONIC BALLASTS. 12. ALL BATTERY EXIT AND EMERGENCY LIGHTING TO BE CONNECTED TO THE UNSWITCHED LEG OF THE LIGHTING CIRCUIT IN THE AREA AS PER CODE. 13. UNLESS SPECIFICALLY INDICATED OTHERWISE, THE ELECTRICAL CONTRACTOR TO COORDINATE WITH ANY SPECIAL SYSTEMS SUPPLIER /CONTR., EX. DENTAL, MEDICAL, KITCHEN,EQUIPMENT ETC. THE EXACT ROUGH-IN REQUIREMENTS FOR THERE EQUIPMENT. ALSO UNLESS INDICATED OTHERWISE, THE ELECTRICAL CONTR. TO BE RESPONSIBLE FOR FINAL CONNECTIONS TO ALL SPECIAL EQUIPMENT. 14. ALL CONDUIT /RACEWAY /CABLES, TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. IF ANY SURFACE WORK IS NECESSARY, IT SHALL BE APPROVED BY THE ARCHITECT /ENGINEER PRIOR TO DOING ANY WORK. 15. E.C. SHALL VISIT THE SITE PRIOR TO BID AND THOROUGHLY INVESTIGATE THE EXISTING CONDITIONS, AS THEY RELATE TO THE SCOPE OF WORK DESCRIBED. MAKE NECESSARY PROVISIONS IN THE BASE BID TO ADEQUATELY ACCOMMODATE THESE CONDITIONS. 16. JUNCTION BOXES FOR LIGHTING CIRCUITING ARE NOT SHOWN FOR CLARITY. THE E.C. IS RESPONSIBLE FOR PROVIDING AND INSTALLING ALL JUNCTION BOXES REQUIRED FOR CIRCUITING OF ALL LIGHT FIXTURES THAT ARE NOT LISTED FOR "THROUGH-BRANCH CIRCUIT WIRING". PROJECT GENERAL NOTES: TO BE MOUNTED AS CLOSE TO TYPICAL DEVICE MOUNTING HEIGHTS DIAGRAM NO SCALE FINISHED FLOOR ARCHITECTURAL PLANS AND DETAILS. DOOR JAMBS AS POSSIBLE. COORDINATE ALL DEVICES WITH 18" - 24" T.V. OUTLET ALL MOUNTING HEIGHTS TYPICAL UNLESS NOTED OTHERWISE. ALL SWITCHES AND THERMOSTATS NOTES: THERMOSTAT OR MECHANICAL SWITCH LIGHT SWITCH CONVENIENCE OUTLET TELEPHONE / DATA OUTLET S T T (OR AS NOTED) 5' - 0'' 4' - 0'' 3' - 6'' 50 60 70 80 S A. COORDINATE OUTLET HEIGHTS WITH ARCHITECTS MILLWORK DWGS. TO INSURE THAT OUTLETS WILL NOT FALL BEHIND CABINETS, BACKSPLASHES, OR INTERFERE WITH WAINSCOTING, ETC. (OR AS NOTED) @ MILLWORK XX" * B. D. *COORDINATE LIGHT SWITCH & OUTLET HEIGHTS WITH ARCHITECTURAL WAINS- COTING AND OR TILE WORK SO AS NOT TO FALL MIDWAY IN THESE FINISHES. * MOUNT VERTICAL OR HORIZONTAL TO MATCH EXISTING DEVICES (TYP) VERIFY WITH MECH. MUD RING ORIENTATION. PE R N E C 3 8 4 - 4 . WA L L PLAN VIEW ELECTRICAL EQUIP. CLEARANCE DETAIL NO SCALE PER NEC 110-26. 36" ELEVATION VIEW 30" WA L L 6' - 6 " A . F . F . 66 " FINISHFLOOR 36" PANEL OR ELECTRICAL EQUIPMENT OR C E I L I N G 6' A . F . F . RECEPTACLE MOUNTING DETAIL NO SCALE TO SUIT WALL RAISED RING CONDUIT(S) ENTRANCE 4'' SQUARE BOX BACK OF COVER W/FELT-TIP MARKER TO BE AS PER SPECIFICATIONS. COVER PLATES - STYLE & COLOR CIRCUIT NUMBER TO BE WRITTEN ON NORMAL POWER COLOR - (SEE SPECS) RECEPTACLE - 20 AMP RATED - SEE SPECIFICATIONS. GROUND CONDUCTORGREEN INSULATED W 50A 208V 1Ø WELDER OUTLET IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PREPARE ALL REQUIRED APPLICATIONS AND INFORMATION REQUIRED TO PROVIDE THE OWNER WITH THE MAXIMUM AMOUNT OF REBATE DOLLARS FROM THE LOCAL UTILITY COMPANY. THE ELECTRICAL CONTRACTOR SHALL SUBMIT VERIFICATION OF THE UTILITY COMPANY PRE-APPLICATION APPROVAL PRIOR TO ORDERING ANY MATERIALS. SPECIAL NOTE FOR UTILITY COMPANY LIGHTING REBATES & INCENTIVES: BOTTOM HALF OF RECEPTACLE SHALL BE SWITCHED MULTI SERVICE A/V FLOOR BOX, LEGRANDE 10 GANG, WITH (4) DUPLEX RECEPTACLES, AND ALL ACCESSORIES, FRAMES, PLATES ETC FOR ALL A/V AND DATA CABLES AS DIRECTED BY OWNER. EC SHALL COORDINATE ALL REQUIREMENTS WITH OWNER PRIOR TO ROUGH-IN 14" ATOMIC CLOCK, LACROSSE #W73143 A/V OUTLET HUBBELL NSAV62M WITH POWER COMPARTMENT ON BOTTOM. W/SURGE RECPT. INSTALL (2)1" COND. FROM LV COMPARTMENT TO ABOVE ACCESSIBLE CEILING FRO EACH OUTLET SHOWN EC SHALL ALSO PROVIDE AND INSTALL (1)50FT. RAPID RUN, CL2-RATED, PC RUNNER CABLE AND (2)INTEGRATED A/V WALL PLATES. WITH RCA/VGA/GA/SOUND INSTALL (1)PLATE IN A/V BOX. INSTALL THE SECOND PLATE AS DIRECTED BY OWNER IN FIELD, IN ONE OF THE J-BOXES SHOWN ON THE DRAWINGS. E1.0 EL E C T R I C A L N O T E S A N D D E T A I L S LIGHTING 1000500 120/240V 1Ø 3W SQ D NQ (NEMA 3R) - "A" 20 1 1500 1500 120 200 RECEPTACLES 20"x39"x5 3/4" SEE RISER 11000 91 87 10500 SEE RISER DETERMINED TO BE FEED TOP DIMENSIONS LOAD FEED BOTTOM WATTS CONDUIT SIZE S.C. INT CAP/BKR.AMPS WATTS FEEDER CONDUCTOR SIZE: TOTAL LOAD/PHASE REMARKS: 35 37 41 39 25 27 29 33 31 19 17 23 21 LOAD NAME 7 11 15 13 9 NO. 3 5 WATTS 1 LOCATION MAKE/MODEL CLASS CIR LOAD LLAMPEABAMPE LOAD/POLE MAIN LUGS ONLY MAIN BRKR. AMPS MAIN SW. BRK PO AMPS PO BRK 40 42 36 38 AMPS. 26 34 32 30 28 22 24 18 20 LOAD NAME 8 16 14 10 12 4 6 2 NO. CIR SURFACE FLUSH SUPPLY WITH INTEGRAL SPD. OH DOORS WATER HEATER120 1000 1000 1000 1000 1000 1000 1000 1000 500 500 500 500 500 500 1500 1500 1500 1500 1500 1000 1000 10002500 SPARE SPARE EH-1 PREPARED SPACE 20 2 --- 1000 1000 EH-1 20 2 --- 1000 1000 CU-1 25 2 --- 1500 1500 SPARE SPARE EH-2 -- - 500 2 20 500 SPARE 1000 1000 1500 1500 1500 Verify wiring method to be used. All electrical work to comply with 2017 NEC. S W F F1 1 F3 F3 F3 3 F5 F4 F5 F5 F5F4 F4F4 F4 F4 SCALE 1 106 T.R. 103CLOS 102WORK 101 HALL 105 WORK 104 SCALE 2 107 F1 F1 F1 F1 F1 S S 1 F2 A-5 A-1 5 5 5 S A-5 2 MAIN SERVICE METER AND DISCONNECT. FIELD VERIFY EXACT LOCATION. M "A" M GFI GFI M M GFI GFI AC GFI AC GFI SCALE 1 106 T.R. 103 CLOS 102 WORK 101 HALL 105 WORK 104 SCALE 2 107 A-7 A-9 A-8,10 4 4 A-18 A-11 A-2,4,6 A-13 A-14 A-28 A-16 A-12 AC GFI AC GFI 1 CU T 1 FC 2 FC 1 EH 1 EH 2 EH T WP GFI MMP TEP P.E. JOB #2189 Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 RE X B U R G , MA D I S O N C O U N T Y TR A N S F E R S T A T I O N S C A L E S ID A H O 867 NOV. '21 E2.0 EL E C T R I C A L F L O O R P L A N S KEY NOTES 1 OVERRIDE SWITCH FOR SCALE ROOM. CONTROL LIGHTING WITH TIME CLOCK AND OVERRIDE SWITCH. PROGRAM TIME CLOCK PER OWNER. CONTROL PHOTO CELL ON, TIME CLOCK OFF. ORIENT PHOTO-CELL TO NORTH SKY. 2" CONDUIT WITH SWEEP 90°'S FOR SCALE CONTROLS. E.C. SHALL FIELD DETERMINE DESTINATION AND EXACT LOCATION WITH SCALE SUPPLIER PRIOR TO ROUGH-IN. SUPPLY THIS FIXTURE WITH SIRE GUARD. 2 3 SCALE: MAIN PLAN - LIGHTING 1/8" = 1' - 0"16'8'0"SCALE: MAIN PLAN - POWER 1/8" = 1' - 0"16'8'0" NO SCALE POWER RISER DIAGRAM M LEVEL MAIN PANEL "A" GROUND PER NEC METER PER POWER CO. 200A 120/240V 1Ø MAIN BREAKER IN NEMA 3R 3"C., 3-#250AL + GROUND SPECIAL NOTE: IN GENERAL SWITCH LEG CONDUCTORS ARE NOT SHOWN. E.C. SHALL PROVIDE AND INSTALL CONDUCTORS AS REQUIRED TO ACHIEVE DESCRIBED CONTROL SCHEMES, INCLUDING ALL 0-10V. CONTROL WIRING. CATALOG # LIGHT FIXTURE SCHEDULE DESCRIPTIONTYPE 4 FT LED SURFACE WRAP CEILING 120 INCLUDED VOLTMOUNT LAMPS MFGR. LITHONIA BLWP4 40L ADP GZ10 LP840 - NOTES* FLOOD LED WALL MOUNTED WALL PER ARCH -LITHONIA CSXW LED 30C 700 40K T4M MVOLT CBA NOTE 4 EGRESS LIGHT LED EXIT WITH WALL PER ARCH -LITHONIA LHQM LED GHO ELASDQWP LO309 NOTE 2 FLOOD LED LOW BAY AC CABLE TO BTM -LITHONIA JEBL 18000LM GL MVOLT 40K 80CRI - FIXTURE NOTES: OPERATE WITH THE INDICATED SWITCHING. 3. "N.L." DENOTES A FIXTURE CONNECTED TO THE UN SWITCHED LEG OF THE LIGHTING CIRCUIT FOR USE AS A NIGHT LIGHT. 2. ALL BATTERY FIXTURES ARE TO BE CONNECTED TO THE UNSWITCHED LEG OF LIGHTING CIRCUIT FEEDING THE AREA. TO THE UNSWITCHED LEG OF THE LIGHTING CIRCUIT. WIRE SUCH THAT UNDER NORMAL POWER CONDITIONS THE FIXTURE WILL 1. THE SUFFIX "EM" DENOTES A FIXTURE SUPPLIED WITH AN EMERGENCY BATTERY DRIVER. CONNECT BATTERY DRIVER 4. COLOR SHALL BE SELECTED BY ARCHITECT. INCLUDED INCLUDED INCLUDED - LED BATTERY EGRESS LIGHT WALL PER ARCH -LITHONIA ELM6L UVOLT LTP HO NOTE 2INCLUDED CORD OF STRUCT.DWHXD ENCLOSURE 4 5 MECHANICAL EQUIPMENT SCHEDULE CIRCUITMCASYMBOL FC 1 COIL DESCRIPTION FAN H.P.VOLTS 12081- Ø 30 - WATTS FEEDER 1/2"C., 2-#12 + GROUND NOTES 1., 2. REMARKS FC 2 COIL FAN 12081-30- CU 1 UNIT CONDENSING 22.1 208 1 - -A-27 MOCP - - 25 EH 1 HEATER ELECTRIC - 208 1 - 2000 A-19- EH 2 HEATER ELECTRIC - 208 1 - 1000 A-24- NOTES 1., 2. NOTE 3. 1/2"C., 2-#12 + GROUND 1/2"C., 2-#10 + GROUND 1/2"C., 2-#12 + GROUND 1/2"C., 2-#12 + GROUND A-23 SCHEDULE NOTES: 1. POWER INDOOR UNIT FROM OUTDOOR UNIT. 2. INSTALL A 1/2" CONDUIT FROM FAN COIL TO COND. UNIT FOR CONTROL. 3. PROVIDE AND INSTALL A LOCAL DISCONNECT. Ensure this AIC rating of this breaker is sufficient Available fault current calculation needed.