HomeMy WebLinkAboutTS4-A-O DATASHEET - 23-00416 - 1212 Barney Dairy Rd - Solar PanelsFlex MLPE
Flex MLPE
The TS4-A-O (Optimization) is the advanced add-on optimization solution that brings smart module
functionality to standard PV modules for higher reliability. Improve energy efficiency by upgrading
underperforming PV systems or adding smart features to new installations.
Complies with 2017 and 2020 NEC rapid shutdown requirements.
The TS4-A-O add-on supports PV modules up to 700W.
TS4-A-O
Module-level PV Optimizer
Module-level optimization
for increased energy yield
and greater design flexibility
Manual or automatic module-level
shutdown. Complies with NEC 2017
and 2020.
Module-level monitoring for
energy production tracking
and system management
Included Features
.
Easy Installation
Snap to standard module frame
or remove brackets for rack mounting
Smart Commissioning
Configure and commission with your
Android or iOS mobile device
12/9/21 PSD-00015-00
Tigo Energy, Inc. | www.tigoenergy.com | sales@tigoenergy.com
TS4-A-O SPECIFICATIONS
ORDERING INFORMATION
For sales info:
sales@tigoenergy.com
For product info:
Visit tigoenergy.com/products
For technical info:
Visit support.tigoenergy.com
For additional info and product selection
assistance, use Tigo’s online design tool at
tigoenergy.com/design
Standard Description
461-00252-32 1500V UL / 1000V IEC, 0.12/1.2m cable, MC4
Options Description
461-00252-62 1500V UL / 1000V IEC, 0.62/1.2m, MC4
461-00261-62 1500V UL / IEC, 0.62/1.2m, EVO2
461-00261-32 1500V UL / IEC, 0.12/1.2m cable, EVO2
Environmental
Operating Temperature Range -40°C to +70°C (-40°F to +158°F)
Outdoor Rating IP68, NEMA 3R
Maximum Elevation 2000m
Mechanical
Dimensions W=138.4mm, L= 139.7mm, H= 22.9mm
Weight 520g
Electrical
Max Input Voltage
(VOC @ Lowest Temperature)80V
Input Voltage Range 16 - 80V*
Maximum Current 15A
Maximum Power 700W
Cable Length (in/out)0.12/1.2m (standard), 0.62/1.2m (optional)
Connectors MC4 (standard), EVO2 (optional)
Communication Type Wireless
Recommended Fuse Rating 30A
120±10
1200±10
W 30
L
8
H
*Clips can be removed for rack mounting
**
TAP required for module-level shutdown and CCA required for monitoring with TS4-A-O.
*Maximum output voltage of the TS4 is dependent on the PV module voltage. Refer to
PV modules nameplate.
Module Frame
Thickness Range
GLASS
1.2mm - 3mm min. 30mm
min. 22mm
ALUMINUM
FRAME
Module frame specifications
for mounting TS4-A