Loading...
HomeMy WebLinkAboutINVERTER - 23-00416 - 1212 Barney Dairy Rd - Solar Panels North America: 15K-2P-N Datasheet Limitless 15K-LV Input Data (PV) Max. Allowed PV Power (STC) 19,500W Nominal Voltage Range 175 - 425V Startup Voltage 125V Max. Input Voltage 500V Max. Input Current per MPPT 26A (self-limiting) No. of MPP Trackers 3 No. of PV Strings per MPPT 2 Output Data (AC) Nominal AC Voltage (L-L) 120/240V, 120/208V, 220V Grid Frequency 50 / 60Hz Real Power, max continuous 15,000W Max. Output Current 62.5A Real Power, max continuous (batteries only, no PV) 12,000W (50A @ 240V) Peak Apparent Power (10s, off-grid) Peak Apparent Power (100ms, off-grid) 24,000VA 30,000VA Max Output Fault Current (5s) Max Output Fault Current (100ms) 94A with PV, 75A (batteries only, no PV) 120A Max. Grid Passthrough Current 200A Power Factor Output Range +/- 0.8 adjustable Backup Transfer Time 5ms CEC Efficiency 96.5% Max Efficiency 97.5% Design (DC to AC) Transformerless DC Stackable Up to 12 in parallel Battery Input Data (DC) Battery Technologies Lithium / Lead Acid Nominal DC Voltage 48V Operating Voltage Range 43 - 63V Capacity 50 — 9900Ah Max. Battery Charge / Discharge Current 275A Charging Controller 3-Stage with Equalization Grid to Battery Charging Efficiency 96.0% External Temperature Sensor Included Current Shunt for Accurate % SOC Integrated Automatic Generator Start Integrated Communication to Lithium CANBus & RS485 General Data Dimensions (H x W x D) 807 x 494 x 306 mm / 31.8 x 19.4 x 12 in Weight 61.2 Kg / 135 lb. Enclosure IP65 / NEMA 3R Ambient Temperature -25~60°C, > 45°C Derating Noise < 30 dB Idle consumption - No Load 60W Wi-Fi & LAN Communication Included Standard Warranty 10 Years Protection and Certifications Electronics Certified Safety by SGS Labs to NEC & UL Specs - NEC 690.4B & NEC 705.4/6 Yes Grid Sell Back — UL1741-2010/2018, IEEE1547a 2003/2014, FCC 15 Class B, UL1741SB, CA Rule 21, HECO Rule 14H Yes PV DC Disconnect Switch — NEC 240.15 Integrated Ground Fault Detection — NEC 690.5 Integrated PV Rapid Shutdown Control — NEC 690.12 Integrated PV Arc Fault Detection — NEC 690.11 Integrated PV Input Lightning Protection Integrated PV String Input Reverse Polarity Protection Integrated AC Output Breaker - 200A Integrated 200A x 2 Battery Breaker / Disconnect Integrated Surge Protection DC Type II / AC Type II 2023 Sol-Ark | Portable Solar LLC Support: (972) 575-8875 Ext. 2, support@sol-ark.com Sales: (972) 575-8875 Ext. 1, sales@sol-ark.com