HomeMy WebLinkAboutFS PLANS - 23-00332 - Madison Jr High - AdditionS201 S202 S203
S204 S205
090
003
070
087 084
027
063
077
061
060
S102
S103S104
S101
020
356
004
391 395
454
8 6 24 0 8 16 24
8 6 24 0 8 16 24
This system as shown on company print no dated
for at
contract no is designed to discharge at a rate of
a maximum area of when supplied with water at a rate of
Occupancy classification:
Commodity classification:
Maximum storage height:
Storage arrangement:
Number of heads flowing:
System Type:
Maximum velocity:
Flow from In-Rack sprinklers:
Flow from Overhead sprinklers:
Flow from Inside Hoses:
Flow from Outside Hoses:
Other fixed flows:
Total flow in system piping:
Additional flow at/beyond source:
Total of all flows:
Calculation results for Design Area
gpm/ft² (L/min/m²) of floor area over
-
Surplus Pressure at Source:
Pressure Required at Source:
Pressure Available at Source:
at at the base of the riser.
Hose stream allowance of is included in the above.
2 COMMONS
PHOENIX FIRE 9/10/2023
MADISON JR HIGH ADDITION 134 Madison Ave, Rexburg, ID 83440
23-210 0.1
1620 ft²199.5 gpm 56.1 psi
LIGHT 5
Wet
16.54 ft/s
0 gpm
199.5 gpm
0 gpm
0 gpm
0 gpm
199.5 gpm
100 gpm
299.5 gpm
56.1 psi
59.6 psi
3.5 psi
Design Area Density:
Calculations using Method
Occupancy Classification:
Design Area System
Additional Outside Hose:
Design Area Size:
Notes:
2 Wet
COMMONS
Demand Hazen-Williams
LIGHT
0.1
100
QR MODIFIER PER NFPA 13 19.3.3.2.3.1
This system as shown on company print no dated
for at
contract no is designed to discharge at a rate of
a maximum area of when supplied with water at a rate of
Occupancy classification:
Commodity classification:
Maximum storage height:
Storage arrangement:
Number of heads flowing:
System Type:
Maximum velocity:
Flow from In-Rack sprinklers:
Flow from Overhead sprinklers:
Flow from Inside Hoses:
Flow from Outside Hoses:
Other fixed flows:
Total flow in system piping:
Additional flow at/beyond source:
Total of all flows:
Calculation results for Design Area
gpm/ft² (L/min/m²) of floor area over
-
Surplus Pressure at Source:
Pressure Required at Source:
Pressure Available at Source:
at at the base of the riser.
Hose stream allowance of is included in the above.
1 CLASSROOM 107
PHOENIX FIRE 9/10/2023
MADISON JR HIGH ADDITION 134 Madison Ave, Rexburg, ID 83440
23-210 0.1
1296 ft²150.6 gpm 53.8 psi
LIGHT 4
Wet
14.35 ft/s
0 gpm
150.6 gpm
0 gpm
0 gpm
0 gpm
150.6 gpm
100 gpm
250.6 gpm
53.8 psi
59.7 psi
6 psi
Design Area Density:
Calculations using Method
Occupancy Classification:
Design Area System
Additional Outside Hose:
Design Area Size:
Notes:
1 Wet
CLASSROOM 107
Demand Hazen-Williams
LIGHT
0.1
100
ROOM CALC 19.3.3.3.5.1(C)
Annular space required. 18.4.1*
Clearance shall be provided around all piping extending
through walls, floors, platforms, and foundations,
including drains, fire department connections, and other
auxiliary piping.
IDAHO STATE FIRE MARSHAL'S OFFICE
FIRE SPRINKLER PLAN REVIEW
ACCEPTED
09/27/2023WITH COMMEN
T
S
IDAHO STATE FIRE MARSHAL'S OFFICE
FIRE SPRINKLER PLAN REVIEW
ACCEPTED
09/27/2023WITH COMMEN
T
S