HomeMy WebLinkAboutFS PLANS - 23-00332 - Madison Jr High - AdditionS201 S202 S203 S204 S205 090 003 070 087 084 027 063 077 061 060 S102 S103S104 S101 020 356 004 391 395 454 8 6 24 0 8 16 24 8 6 24 0 8 16 24 This system as shown on company print no dated for at contract no is designed to discharge at a rate of a maximum area of when supplied with water at a rate of Occupancy classification: Commodity classification: Maximum storage height: Storage arrangement: Number of heads flowing: System Type: Maximum velocity: Flow from In-Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: Calculation results for Design Area gpm/ft² (L/min/m²) of floor area over - Surplus Pressure at Source: Pressure Required at Source: Pressure Available at Source: at at the base of the riser. Hose stream allowance of is included in the above. 2 COMMONS PHOENIX FIRE 9/10/2023 MADISON JR HIGH ADDITION 134 Madison Ave, Rexburg, ID 83440 23-210 0.1 1620 ft²199.5 gpm 56.1 psi LIGHT 5 Wet 16.54 ft/s 0 gpm 199.5 gpm 0 gpm 0 gpm 0 gpm 199.5 gpm 100 gpm 299.5 gpm 56.1 psi 59.6 psi 3.5 psi Design Area Density: Calculations using Method Occupancy Classification: Design Area System Additional Outside Hose: Design Area Size: Notes: 2 Wet COMMONS Demand Hazen-Williams LIGHT 0.1 100 QR MODIFIER PER NFPA 13 19.3.3.2.3.1 This system as shown on company print no dated for at contract no is designed to discharge at a rate of a maximum area of when supplied with water at a rate of Occupancy classification: Commodity classification: Maximum storage height: Storage arrangement: Number of heads flowing: System Type: Maximum velocity: Flow from In-Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: Calculation results for Design Area gpm/ft² (L/min/m²) of floor area over - Surplus Pressure at Source: Pressure Required at Source: Pressure Available at Source: at at the base of the riser. Hose stream allowance of is included in the above. 1 CLASSROOM 107 PHOENIX FIRE 9/10/2023 MADISON JR HIGH ADDITION 134 Madison Ave, Rexburg, ID 83440 23-210 0.1 1296 ft²150.6 gpm 53.8 psi LIGHT 4 Wet 14.35 ft/s 0 gpm 150.6 gpm 0 gpm 0 gpm 0 gpm 150.6 gpm 100 gpm 250.6 gpm 53.8 psi 59.7 psi 6 psi Design Area Density: Calculations using Method Occupancy Classification: Design Area System Additional Outside Hose: Design Area Size: Notes: 1 Wet CLASSROOM 107 Demand Hazen-Williams LIGHT 0.1 100 ROOM CALC 19.3.3.3.5.1(C) Annular space required. 18.4.1* Clearance shall be provided around all piping extending through walls, floors, platforms, and foundations, including drains, fire department connections, and other auxiliary piping. IDAHO STATE FIRE MARSHAL'S OFFICE FIRE SPRINKLER PLAN REVIEW ACCEPTED 09/27/2023WITH COMMEN T S IDAHO STATE FIRE MARSHAL'S OFFICE FIRE SPRINKLER PLAN REVIEW ACCEPTED 09/27/2023WITH COMMEN T S