HomeMy WebLinkAboutFDC RELOCATION - 23-00332 - Madison Jr High - AdditionGENERAL STRUCTURAL NOTES (APPLY UNLESS NOTED OTHERWISE ON PLANS/DETAILS) GENERAL REQUIREMENTS: 1.THE STRUCTURAL SYSTEMS AND MEMBERS DEPICTED HEREIN HAVE BEEN DESIGNED PRIMARILY TO SAFEGUARD AGAINST MAJOR STRUCTURAL DAMAGE AND LOSS OF LIFE, NOT TO LIMIT DAMAGE OR MAINTAIN FUNCTION (IBC SECTION 101.3). 2.THESE DRAWINGS, AND THEIR ASSOCIATED STRUCTURAL CALCULATIONS, HAVE BEEN PERFORMED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE STRUCTURAL ENGINEER'S IN THIS OR SIMILAR LOCALITIES. THEY NECESSARILY ASSUME THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKMEN WHO HAVE A WORKING KNOWLEDGE OF THE INTERNATIONAL BUILDING CODE CONVENTIONAL FRAMING REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR FRAMING ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, IT IS UNDERSTOOD THAT THE CONTRACTOR WILL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR ALL MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3.THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION SUCH THAT DESIGN LIVE LOAD PER SQUARE FOOT AS STATED HEREIN IS NOT EXCEEDED. OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF AN OPTION IS USED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES, AND SHALL COORDINATE ALL DETAILS. 4.WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. TYPICAL DETAILS AND NOTES ARE NOT NECESSARILY INDICATED ON THE PLANS, BUT SHALL APPLY NONE-THE-LESS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. DETAILS MAY SHOW ONLY ONE SIDE OF CONNECTION OR MAY OMIT INFORMATION FOR CLARITY. 5.ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ARCHITECT AND STRUCTURAL ENGINEER. 6.ANY INSPECTIONS, SPECIAL (IBC CHAPTER 17) OR OTHERWISE THAT ARE REQUIRED BY THE BUILDING CODES, LOCAL BUILDING DEPARTMENTS, OR BY THESE PLANS SHALL BE DONE BY AN INDEPENDENT INSPECTION COMPANY OR THE BUILDING DEPARTMENT, SITE VISITS BY THE STRUCTURAL ENGINEER DO NOT CONSTITUTE AN OFFICIAL INSPECTION, UNLESS SPECIFICALLY CONTRACTED FOR. 7.SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS IN ADDITION TO ITEMS REQUIRED BY ARCHITECTURAL SPECIFICATIONS, THE CONTRACTOR SHALL REVIEW ALL SHOP DRAWINGS PRIOR TO SUBMITTAL. ITEMS NOT IN ACCORDANCE WITH CONTRACT DRAWINGS SHALL BE FLAGGED UPON HIS REVIEW. VERIFY ALL DIMENSIONS WITH ARCHITECT. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM ORIGINAL CONTRACT DRAWINGS SHALL BE CLOUDED. ANY OF THE AFOREMENTIONED WHICH ARE NOT CLOUDED OR FLAGGED BY SUBMITTING PARTIES, SHALL NOT BE CONSIDERED APPROVED AFTER THE STRUCTURAL ENGINEER'S REVIEW, UNLESS NOTED ACCORDINGLY. ANY ENGINEERING PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW, SHALL BEAR THE SEAL OF A STRUCTURAL ENGINEER REGISTERED IN THE APPROPRIATE STATE. THE SHOP DRAWINGS DO NOT REPLACE THE ORIGINAL CONTRACT DRAWINGS. ITEMS OMITTED OR SHOWN INCORRECTLY AND ARE NOT FLAGGED BY THE STRUCTURAL ENGINEER ARE NOT TO BE CONSIDERED CHANGES TO ORIGINAL DRAWINGS. THE ADEQUACY OF ENGINEERING DESIGNS AND LAYOUT PERFORMED BY THE OTHERS RESTS WITH THE DESIGNING OR SUBMITTING AUTHORITY. REVIEWING IS INTENDED ONLY AS AN AID TO THE CONTRACTOR IN OBTAINING CORRECT SHOP DRAWINGS. RESPONSIBILITY FOR CORRECTNESS SHALL REST WITH THE CONTRACTOR. ALLOW (5) WORKING DAYS FOR THE STRUCTURAL ENGINEER'S REVIEW. ONE COPY OF EACH SUBMITTAL WILL BE RETAINED FOR THE STRUCTURAL ENGINEER'S RECORDS. BASIS FOR DESIGN: 1.BUILDING CODE: 2018 EDITION OF THE IBC WITH CITY/COUNTY AMENDMENTS. RISK CATEGORY = III 4. SEISMIC DESIGN PARAMETERS: ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE IMPORTANCE FACTOR Ie = 1.25 SITE CLASS D SEISMIC DESIGN CATEGORY D MAPPED SPECTRAL RESPONSE ACCELERATIONS S1 = 0.144, SS = 0.373 DESIGN SPECTRAL RESPONSE ACCELERATIONS SD1 = 0.222, SDS = 0.373 PERCENT SNOW INCLUDED WITH SEISMIC LOADS 20 VERTICAL SHEAR TRANSFER ELEMENTS: PLYWOOD SHEARWALL(S)R = 6.5, CS = 0.072 5. WIND DESIGN PARAMETERS (STRENGTH): ULTIMATE WIND SPEED 115 MPH (3 SECOND GUST) WIND EXPOSURE C IMPORTANCE FACTOR Iw = 1.00 INTERNAL PRESSURE COEFFICIENT -0.18 COMPONENT AND CLADDING PRESSURE 26.3 PSF NET UPLIFT ON ROOF 13.6 PSF 2. VERTICAL LOADS: LOCATION LIVE / SNOW LOAD DEAD LOAD ROOF 40 PSF 20 PSF 3. DEFLECTION LIMITS: ELEMENTS LIVE LOAD TOTAL LOAD BEAMS L/360 L/240 3.A ONE-THIRD INCREASE IN BEARING PRESSURES IS ALLOWED WITH SEISMIC OR WIND LOAD COMBINATIONS. LATERAL BEARING AND LATERAL SLIDING RESISTANCE MAY BE COMBINED. 4.ALL FOUNDATIONS SHALL BEAR ON A MINIMUM OF 2' OF STRUCTURAL FILL COMPACTED TO 95% DRY DENSITY (STANDARD PROCTOR) IN LIFTS NO LARGER THAT 8" THICK. PRIOR TO PLACEMENT OF FILL, THE NATIVE SOIL SHOULD BE COMPACTED IN PLACE TO AT LEAST 95% OF ITS MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D-698 PER GEOTECHNICAL REPORT. GRADE IS DEFINED AS LOWEST ADJACENT GRADE WITHIN 5 FEET OF THE BUILDING FOR PERIMETER FOOTINGS. WHERE EXTERIOR PAVING OR CONCRETE IS DIRECTLY ADJACENT TO BUILDING, GRADE IS DEFINED AS TOP OF EXTERIOR PAVING AT LEAST 5 FEET FROM BUILDING. CONCRETE FOOTING EXCAVATIONS SHALL BE CLEAN AND FREE OF LOOSE DEBRIS OR UN-COMPACTED MATERIAL AT TIME OF CONCRETE PLACEMENT. 5.CONCRETE SLABS ON GRADE SHALL BE SUPPORTED ON A 6 INCH (MIN) LAYER OF FREE-DRAINING GRANULAR MAT (DRAINAGE FILL COURSE). THE MAT SHOULD CONSIST OF A WELL GRADED SAND AND GRAVEL MIXTURE WITH MAXIMUM 3/4-INCH CRUSHED AGGREGATE. THE GRANULAR MAT SHOULD BE COMPACTED TO NO LESS THAN 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D1557. 6.BACKFILL AGAINST RESTRAINED WALLS SHALL NOT BE PLACED UNTIL AFTER THE WALLS ARE SUPPORTED BY THE COMPLETION OF INTERIOR FLOOR SYSTEMS AND CONCRETE OR GROUT STRENGTH HAS REACHED THE 28 DAY STRENGTH LISTED BELOW. THE SOIL DESIGN VALUES FOR THE FOUNDATION ARE: ALLOWABLE BEARING PRESSURE 3000 PSF ALLOWABLE LATERAL BEARING PRESSURE 150 PSF/FT ALLOWABLE LATERAL SLIDING COEFFICIENT 0.25 FOUNDATION BEARING DEPTH 42" BELOW FINISHED GRADE CONCRETE: 2.ALL NORMAL WEIGHT CONCRETE SHALL BE REGULAR WEIGHT OF 150 POUNDS PER CUBIC FOOT USING HARD-ROCK AGGREGATES. AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. 3.LAP SPLICES FOR BEAMS AND FLOOR SLABS SHALL BE ACCORDING TO CHAPTER 12 OF ACI 318 OR LAP SCHEDULE ON THESE DRAWINGS. STAGGER SPLICES A MINIMUM OF ONE LAP LENGTH. NO TACK WELDING OF REINFORCING BARS ALLOWED WITHOUT PRIOR REVIEW OF PROCEDURE WITH THE STRUCTURAL ENGINEER. LATEST ACI CODE AND DETAILING MANUAL APPLY. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. VERTICAL WALL BARS SHALL BE SPLICED AT OR NEAR FLOOR LINES. 4.ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING STEEL NOT NOTED AS "CLEAR" OR "CLR" ARE TO CENTER OF STEEL. MINIMUM COVER FOR NON-PRESTRESSED CONCRETE REINFORCING SHALL BE AS FOLLOWS: 5.MAXIMUM SLUMP FOR ALL CONCRETE SHALL BE 6". PORTLAND CEMENT SHALL CONFORM TO ASTM C150. TYPE V CEMENT SHALL BE USED FOR CONCRETE IN CONTACT WITH ALKALINE SOIL, AND TYPE II ELSEWHERE. 6.NO MORE THAN 90 MINUTES SHALL ELAPSE BETWEEN CONCRETE BATCHING AND CONCRETE PLACEMENT UNLESS APPROVED BY THE TESTING AGENCY. 7.CONCRETE PLACEMENT AND QUALITY SHALL BE PER RECOMMENDATIONS IN ACI 614, ACI 301 AND ACI 318. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS ON GRADE NEED BE VIBRATED ONLY AROUND AND UNDER FLOOR DUCTS, ETC. CAST CLOSURE POUR, WHERE SHOWN ON PLANS AROUND COLUMNS AFTER COLUMN DEAD LOAD IS APPLIED. REMOVE ALL DEBRIS FROM FORMS BEFORE PLACING CONCRETE. ALL ITEMS TO BE CAST IN CONCRETE SUCH AS REINFORCING, DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY POSITIONED IN THE FORMS BEFORE PLACING THE CONCRETE. 8.ALL CONCRETE SLABS ON GRADE SHALL BE DIVIDED INTO AREAS BY CONTROL JOINTS (KEYED OR SAW CUT) SUCH THAT ONE SLAB AREA DOES NOT EXCEED A MAXIMUM LENGTH OF 24 TIMES THE SLAB THICKNESS IN BOTH DIRECTIONS (EXAMPLE: 4" SLAB = 8'-0" LENGTH). SQUARE LAYOUTS ARE PREFERRED, BUT THE SLAB GEOMETRY MAY DICTATE OTHERWISE. THE RATIO OF THE LONG TO SHORT DISTANCE SHALL NOT EXCEED 1.3. IT IS RECOMMENDED THAT SAW CUTS BE MADE WITHIN 16 HOURS OF CONCRETE BATCHING. KEYED CONTROL JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING POURING, ALL OTHER JOINTS MAY BE SAW CUT. 9.HORIZONTAL PIPES AND ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE AND SLABS ON GRADE EXCEPT WHERE SPECIFICALLY APPROVED OR NOTED BY THE STRUCTURAL ENGINEER. PIPES AND CONDUITS SHALL NOT IMPAIR THE STRENGTH OF THE WORK. 10.FLY ASH MAY BE USED ONLY IF PERMITTED BY ARCHITECTURAL SPECIFICATIONS AND SHALL BE LIMITED TO 18 PERCENT OF CEMENTITIOUS MATERIALS AND SHALL HAVE A REPLACEMENT FACTOR OF 1.2 RELATIVE TO CEMENT REPLACED. NO FLY ASH ADDITIVES SHALL BE USED IN FLATWORK OR ARCHITECTURALLY EXPOSED CONCRETE. 11.COLD/HOT WEATHER CONCRETE CONSTRUCTION: PROTECT CONCRETE FROM DAMAGE OR REDUCED STRENGTH IN COMPLIANCE WITH ACI 305 AND 306. 12.CONCRETE MIXES SHALL BE DESIGNED BY A CERTIFIED LABORATORY AND APPROVED BY THE STRUCTURAL ENGINEER. 13.LIMIT ALKALI-SILICA REACTION (ASR) TO 0.1% EXPANSION AT 28 DAYS IN CONCRETE MIX AT ALL EXTERIOR CONCRETE AND INTERIOR CONCRETE EXPOSED TO MOISTURE. LOCATION:MINIMUM COVER TOLERANCE CAST AGAINST EARTH (FOOTINGS)3"± 3 8" SLABS ON GRADE 112"± 14" EXPOSED TO EARTH OR WEATHER - #5 AND SMALLER 112"± 3 8" EXPOSED TO EARTH OR WEATHER - #6 AND LARGER 2"± 3 8" NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND ROOF SLAB 1"18" STRUCTURAL SLABS AND WALLS 3 4"18" BEAMS AND COLUMNS (PRIMARY) REINFORCEMENT, TIES, STIRRUPS AND SPIRALS 112"3 8" 1. MINIMUM 28 DAY CONCRETE STRENGTH SHALL BE AS FOLLOWS: USE:CONCRETE STRENGTH: MAX W/C RATIO AIR ENTRAINMENT FOOTINGS 3500 PSI 0.50 5.5% ± 1% FOUNDATION WALLS 4500 PSI 0.45 5.5% ± 1% INTERIOR CONCRETE SLABS ON GRADE 3500 PSI 0.45 N/A REINFORCING STEEL: 1.ASTM A615 GRADE 60 (FY = 60 KSI) DEFORMED BARS FOR ALL BARS #4 AND LARGER. ASTM A615 GRADE 40 (FY = 40 KSI) DEFORMED BARS FOR ALL BARS #3 AND SMALLER. GRADE 60 DEFORMED BARS SHALL BE USED FOR CONCRETE WALLS, BEAMS, ELEVATED SLABS AND COLUMN REINFORCING. 2.WELDING OF REINFORCING BARS SHALL BE MADE ONLY TO ASTM A706 GRADE 60 BARS AND ONLY USING E90 SERIES RODS. WELDING OF REINFORCING BARS SHALL BE MADE ONLY AT LOCATIONS SHOWN ON PLANS OR DETAILS. 3.REINFORCING BAR SPACING GIVEN ARE MAXIMUM ON CENTERS. ALL BARS PER CRSI SPECIFICATIONS AND HANDBOOK. DOWEL ALL VERTICAL REINFORCING TO FOUNDATION. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. WOOD: 1.GENERAL: DO NOT NOTCH OR DRILL JOISTS, BEAMS, OR LOAD BEARING STUDS WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER THROUGH THE ARCHITECT. DOUBLE UP JOISTS AND BLOCKING UNDER PARTITIONS. PROVIDE 2" (NOMINAL) SOLID BLOCKING AT SUPPORTS OF ALL JOISTS. UNLESS NOTED OTHERWISE ON PLANS/DETAILS PROVIDE 2x SOLID BLOCKING AT MID-HEIGHT OF BEARING STUD WALLS. ALL NAILING NOT NOTED SHALL BE ACCORDING TO IBC TABLE 2304.10.1. JOIST HANGERS AND OTHER MISC. FRAMING ANCHORS SHALL BE SIMPSON STRONG-TIE COMPANY, INC. OR OTHER MANUFACTURER WITH CURRENT ICC-ES APPROVAL. 2.SAWN LUMBER: FRAMING LUMBER SHALL COMPLY WITH THE LATEST EDITION OF THE GRADING RULES OF THE WESTERN WOOD PRODUCTS ASSOCIATION (WWPA) OR THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB). ALL SAWN LUMBER SHALL BE STAMPED WITH THE GRADE MARK OF AN APPROVED LUMBER GRADING AGENCY. SAWN LUMBER SHALL HAVE THE FOLLOWING MINIMUM GRADE UNLESS NOTED OTHERWISE IN SCHEDULES: USE:MATERIAL: 2x4 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) 2x6 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) JOISTS, TOP PLATES AND ALL OTHER SAWN LUMBER DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) BEAMS AND POSTS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) LOCATION:NOMINAL THICKNESS: SPAN INDEX RATING: EDGE ATTACHMENT: FIELD ATTACHMENT: WALL 7 16" OR 12"24 16 8d AT 6" O.C.8d AT 12" O.C. ROOF 7 16" OR 12"24 16 8d AT 6" O.C.8d AT 12" O.C. ROOF 15 32" OR 12"3216 8d AT 6" O.C.8d AT 12" O.C. ROOF 19 32" OR 5 8"40 20 10d AT 6" O.C.10d AT 12" O.C. ROOF 23 32" OR 3 4"48 24 10d AT 6" O.C.10d AT 12" O.C. ROOF 7 8"60 32 10d AT 6" O.C.10d AT 12" O.C. FLOOR 3 4" T&G 48 24 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 7 8" T&G 60 32 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 118" T&G 60 48 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. 3.PLYWOOD: ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING CONFORMING TO STANDARD PS 1-95. LAY UP PLYWOOD WITH FACE GRAIN IN PERPENDICULAR TO SUPPORTS (ON ROOFS WHERE PLYWOOD IS LAID UP WITH FACE GRAIN PARALLEL TO SUPPORTS, USE A MINIMUM OF 5-PLY PLYWOOD, STAGGER JOINTS). ALL NAILING, COMMON NAILS. BLOCKING AT PANEL EDGES WHERE INDICATED ON PLANS. ALL PLYWOOD SHALL BE OF THE FOLLOWING NOMINAL THICKNESS, SPAN/INDEX RATING AND SHALL BE NAILED AS FOLLOWS UNLESS NOTED OTHERWISE ON THE PLANS: DEFERRED SUBMITTAL ITEMS: PREFABRICATED WOOD ROOF TRUSSES BRICK VENEER ANCHORAGE: BRICK VENEER ANCHOR CLIPS, ANCHORS, AND ATTACHMENTS SHALL BE HOT-DIPPED GALVANIZED AND EITHER OF THE FOLLOWING FROM HOHMANN & BARNARD, INC. OR APPROVED EQUAL: 1.DW-10HS W/ S.I.S. (SEISMICLIP INTERLOCKING SYSTEM) SEISMIC VENEER ANCHORS 2.345-BT W/ S.I.S. (SEISMICLIP INTERLOCKING SYSTEM) SEISMIC VENEER ANCHORS INSTALLATION: 3.CLIPS SHALL BE ATTACHED AT 24" O.C. HORIZONTAL AND 16" O.C. VERTICAL (MAX) USING #10 HOT-DIPPED GALVANIZED SCREWS. 4.WHERE WOOD BACKUP IS USED, PROVIDE SHEATHING AND WATERPROOFING AS REQUIRED. 5.PROVIDE CONTINUOUS HOT-DIPPED GALVANIZED WIRE (9-GAUGE OR 3 16"Ø) ATTACHED TO EACH CLIP. SHEET INDEX SHEET DESCRIPTION DETAILS S1.0 GENERAL STRUCTURAL NOTES --- S1.1 TYPICAL DETAILS T-SERIES S1.2 TYPICAL DETAILS T-SERIES S2.0 FOUNDATION PLAN - OVERALL --- S2.1 FOUNDATION PLAN - AREA A --- S2.3 FOUNDATION PLAN - AREA B --- S2.4 ROOF FRAMING PLAN - OVERALL --- S2.5 ROOF FRAMING PLAN - AREA A --- S2.6 ROOF FRAMING PLAN - AREA B --- S3.0 FOUNDATION DETAILS 100 - SERIES S4.0 FRAMING DETAILS 200 - SERIES CAST IN PLACE CENTERLINE CENTERLINE OF BEAM CENTERLINE OF COLUMN CENTERLINE OF WALL CLEAR CONCRETE CONCRETE CONTROL JOINT CONCRETE SAWCUT JOINT CONCRETE MASONRY UNIT CONNECTION CONTINUOUS DEAD LOAD DOWN DRAWING(S) EQUAL EQUIPMENT EXPANSION JOINT EACH WAY FINISHED FLOOR FACE OF STEEL FACE OF WALL GAUGE GALVANIZED GENERAL STRUCTURAL NOTES CENTERLINE OF FOOTING FACE OF MEMBER EXPANSION BOLT EDGE OF SLAB DIAMETER GALV GSN DN. DWG(S) EQ EQUIP EXP. JT (E.J.) E.W. F.F. F.O.S. F.O.W. GA F.O.M. EXP. BOLT E.O.S. Ø OR DIA. C.I.P. C L C.L.B. C.L.C. C.L.W. CLR CONC C.C.J. C.S.J. C.M.U. CONN. CONT D L C.L.F. W/WITH W/O WITHOUT T.O.P. U.N.O. W.W.F. TYP VERT T.O.S. T.O.W. T.O.D. T.O.F. T.O.L. T.O.M. STD T.O.B. T L SLH SLV SIM SQ PSF PSI REINF PREFAB OPP P.C. PLF N.T.S. O.C. O.F.W. TOP OF FOOTING UNLESS NOTED OTHERWISE WELDED WIRE FABRIC TOP OF MASONRY TOP OF PLATE TOP OF STEEL TOP OF WALL TYPICAL VERTICAL STANDARD TOP OF BEAM TOP OF DECK TOP OF LEDGER TOTAL LOAD OUTSIDE FACE OF WALL PRECAST CONCRETE POUNDS PER LINEAR FOOT POUNDS PER SQUARE INCH SHORT LEG VERTICAL SHORT LEG HORIZONTAL REINFORCING SIMILAR SQUARE NOT TO SCALE ON CENTER OPPOSITE PREFABRICATED AGGREGATE BASE COURSE AIR CONDITIONER ABOVE FINISHED FLOOR ALTERNATE ANCHOR BOLT AT (MEASUREMENT) BEAM BOTTOM OF BEAM BOTTOM OF DECK BEARING BELOW FINISHED FLOOR BOTTOM OF FOOTING A.B.C. A/C A.F.F. ALT A.B. @ BM B.O.B. B.O.D. BRG B.F.F B.O.F. ABBREVIATIONS LBS (#) MFR('S) M.C.J. MECH N/A LLV LLH HORIZ K(KIP) L L LONG LEG VERTICAL MANUFACTURER('S) MASONRY CONTROL JOINT NOT APPLICABLE LONG LEG HORIZONTAL POUNDS MECHANICAL HORIZONTAL 1000 POUNDS LIVE LOAD EXISTING(E) MIN MINIMUM MAX MAXIMUM POUNDS PER SQUARE FOOT GLUED-LAMINATED BEAMGLB PFT PREFAB FLOOR TRUSSES PRT PREFAB ROOF TRUSSES I.F.W.INSIDE FACE OF WALL PT PRESSURE TREATED CONCRETE COLUMNC.C. RME ROOF MOUNTED EQUIPMENT GIRDER TRUSSGT SPECIAL INSPECTION ITEMS: 1.THE OWNER OR THE OWNER'S AUTHORIZED AGENT, OTHER THAN THE CONTRACTOR, SHALL EMPLOY ONE OR MORE APPROVED AGENCIES TO PROVIDE SPECIAL INSPECTIONS AND TESTS DURING CONSTRUCTION ON THE TYPES OF WORK SPECIFIED PER IBC SECTION 1705 AND IDENTIFY THE APPROVED AGENCIES TO THE BUILDING OFFICIAL. SPECIAL INSPECTIONS ARE REQUIRED AS FOLLOWS: 2.QUALITY ASSURANCE PROGRAM: A.THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED TO BE CERTAIN IT CONFORMS WITH THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS. B.THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL, AND TO THE STRUCTURAL ENGINEER OF RECORD. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED, TO THE DESIGN AUTHORITY AND THE BUILDING OFFICIAL. ANCHORAGE TO CONCRETE: ADHESIVE ANCHORS: HILTI HIT-HY 200 PER ICC ESR-3187 HILTI HIT-RE 500 V3 PER ICC ESR-3814 SIMPSON AT-XP PER IAPMO ER-263 SIMPSON SET-3G PER ICC ESR-4073 MECHANICAL ANCHORS: HILTI KWIK HUS PER ICC ESR-3027 HILTI KWIK BOLT-TZ EXPANSION ANCHORS PER ICC ESR-1917 SIMPSON TITEN HD PER ICC ESR-2713 SIMPSON STRONG BOLT-2 PER ICC ESR-3037 ADHESIVES: HILTI HIT-HY 200 PER ICC ESR-3187 HILTI HIT-RE 500 V3 PER ICC ESR-3814 SIMPSON AT-XP PER IAPMO ER-263 SIMPSON SET-3G PER ICC ESR-4073 2.SUBSTITUTION REQUESTS FOR ALTERNATE PRODUCTS MUST BE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER OF RECORD PRIOR TO USE. CONTRACTOR SHALL PROVIDE CALCULATIONS DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE PERFORMANCE VALUES OF THE SPECIFIED PRODUCT. SUBSTITUTIONS WILL BE EVALUATED BY THEIR HAVING AN ICC ESR OR IAPMO ER SHOWING COMPLIANCE WITH THE RELEVANT BUILDING CODE FOR SEISMIC USES, LOAD RESISTANCE, INSTALLATION CATEGORY, AND AVAILABILITY OF COMPREHENSIVE INSTALLATION INSTRUCTIONS. ADHESIVE ANCHOR EVALUATION WILL ALSO CONSIDER CREEP, IN-SERVICE TEMPERATURE AND INSTALLATION TEMPERATURE. 3.INSTALL THE ANCHORS PER THE MANUFACTURER INSTRUCTIONS, AS INCLUDED IN THE ANCHOR PACKAGING. 4.THE CONTRACTOR SHALL ARRANGE AN ANCHOR MANUFACTURER'S REPRESENTATIVE TO PROVIDE ONSITE INSTALLATION TRAINING FOR ALL OF THEIR ANCHORING PRODUCTS SPECIFIED. THE STRUCTURAL ENGINEER OF RECORD MUST RECEIVE DOCUMENTED CONFIRMATION THAT ALL OF THE CONTRACTOR'S PERSONNEL WHO INSTALL ANCHORS ARE TRAINED PRIOR TO THE COMMENCEMENT OF INSTALLING ANCHORS. 5.ANCHOR CAPACITY IS DEPENDANT UPON SPACING BETWEEN ADJACENT ANCHORS AND PROXIMITY OF ANCHORS TO EDGE OF CONCRETE. INSTALL ANCHORS IN ACCORDANCE WITH SPACING AND EDGE CLEARANCES INDICATED ON THE DRAWINGS. POST-INSTALLED ANCHORS: 1.EXCEPT WHERE INDICATED ON THE DRAWINGS, POST-INSTALLED ANCHORS SHALL CONSIST OF THE FOLLOWING ANCHOR TYPES. ALL ANCHORS ARE TO BE INSTALLED PER THE MANUFACTURERS RECOMMENDATIONS. SCREWS AT FLOOR SHEATHING SHALL BE #8 SCREWS AND SHALL PENETRATE AT LEAST 112" INTO THE SUPPORTING MEMBER. ALL FLOOR SHEATHING SHALL BE GLUED TO SUPPORTING MEMBERS WITH AN APA AFG-01 QUALIFIED ADHESIVE. PLYWOOD ALTERNATE: AMERICAN PLYWOOD ASSOCIATION PERFORMANCE RATED SHEATHING MAY BE USED AS AN ALTERNATE TO PLYWOOD WITH PRIOR APPROVAL OF OWNER, ARCHITECT AND ROOFER. IT MAY NOT BE USED ON ROOFS WHERE BUILT-UP ROOF SYSTEM IS TO BE GUARANTEED BY ROOFER. RATED SHEATHING SHALL COMPLY WITH CURRENT ICC-ES REPORTS AND SHALL HAVE A SPAN RATING EQUIVALENT TO OR BETTER THAN THE PLYWOOD IT REPLACES. ATTACHMENT AND THICKNESS (WITHIN 132") SHALL BE THE SAME AS THE PLYWOOD IT REPLACES. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 4.NOMINAL 2x AND 3x DECKING. TONGUE AND GROOVE TYPE. MINIMUM Fb = 1,600 PSI, MINIMUM E = 1,300,000 PSI. INSTALL WITH TONGUES UP SLOPE ON PITCHED ROOFS, AND OUTWARD IN THE DIRECTION OF LAYING ON FLAT ROOFS. NAIL EACH PLANK WITH 16d TOENAIL (THRU THE TONGUE) AND 16d FACE NAIL AT EACH SUPPORT. DECK SHALL BE INSTALLED AS SIMPLE SPAN WITH ALL PLANKS BEARING ON TWO SUPPORTS. FOR REFERENCE AND/OR ADDITIONAL INFORMATION SEE AITC 117-2010. 5.GLUED-LAMINATED BEAMS (GLB): GLUED-LAMINATED BEAMS SHALL BE DOUGLAS FIR COMBINATION AT 24F-V4 AT SIMPLE SPAN BEAMS AND 24F-V8 AT MULTI-SPAN AND CANTILEVERED BEAMS WITH THE FOLLOWING MINIMUM PROPERTIES: FB = 2,400 PSI, FV = 190 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,800 KSI. ALL BEAMS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. BEAMS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. CAMBER AS SHOWN ON DRAWINGS. STANDARD CAMBER IS BASED ON A RADIUS OF CURVATURE OF 5000 FEET. 6.GLUED-LAMINATED COLUMNS: GLUED-LAMINATED COLUMNS SHALL BE DOUGLAS FIR COMBINATION 3 WITH THE FOLLOWING MINIMUM PROPERTIES: FBY = 2,100 PSI, FBX = 2000 PSI, FVY = 230 PSI, FVX = 265 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,900 KSI. ALL COLUMNS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. COLUMNS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. 7.LAMINATED VENEER LUMBER (LVL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LVLs SHALL BE: FB = 2,600 PSI, FV = 285 PSI, E = 2,000 KSI. 8.PARALLEL STRAND LUMBER (PSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR PSLs SHALL BE: FB = 2,900 PSI, FV = 290 PSI, E = 2,200 KSI. 9.LAMINATED STRAND LUMBER (LSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LSLs SHALL BE: FB = 2,325 PSI, FV = 310 PSI, E = 1,550 KSI. 10.SILL PLATES RESTING ON CONCRETE OR MASONRY SHALL BE OF TREATED FIR. SHEAR WALLS AND EXTERIOR WALL SILLS AT CONCRETE SLAB SHALL HAVE A MINIMUM OF (2) ANCHOR BOLTS PER PIECE. PROVIDE ANCHOR BOLT AT 9" MAXIMUM, 4" MINIMUM FROM THE END OF EACH PIECE AT SPLICE OR END OF WALL. MAXIMUM ANCHOR BOLT SPACING SHALL BE 72" ON CENTER UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. ALL ANCHOR BOLTS (OTHER THAN BOLTS FOR HOLDOWNS) SHALL EMBED 7" INTO CONCRETE. ANCHOR BOLTS FOR HOLDOWNS SHALL NOT BE CONSIDERED AS PART OF REQUIRED ANCHOR BOLTS ON SHEAR WALLS. ALL EXTERIOR WALLS SHALL BE SECURED WITH MINIMUM ANCHOR BOLTS. INTERIOR WALLS MAY BE SECURED TO CONCRETE WITH EITHER ANCHOR BOLTS OR POWER DRIVEN SHOT PINS UNLESS NOTED OTHERWISE ON PLANS. 11.BOLTING: ALL BOLTS IN WOOD CONNECTIONS SHALL CONFORM TO ASTM A307. BOLTS SHALL BE INSTALLED IN HOLES BORED WITH A BIT 116" LARGER THAN THE Ø (DIAMETER) OF THE BOLT. BOLTS AND NUTS SEATING ON WOOD SHALL HAVE CUT STEEL WASHERS UNDER HEADS AND NUTS. NICK THREADS TO PREVENT LOOSENING. 12.PREFABRICATED WOOD TRUSSES: PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED TO SUPPORT SELF WEIGHT PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS. WHERE UNINHABITABLE ATTIC SPACE CAN BE USED FOR STORAGE, A 20 PSF LIVE LOAD ON THE BOTTOM CHORD SHALL BE INCLUDED IN THE ANALYSIS. BRIDGING SIZE AND SPACING BY TRUSS MANUFACTURER UNLESS NOTED OTHERWISE. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED ENGINEER FOR REVIEW PRIOR TO MANUFACTURE FOR BOTH ROOF AND FLOOR TRUSSES WHEN USED. SHOP DRAWINGS SHALL SHOW ANY SPECIAL DETAILS REQUIRED AT BEARING POINTS. ALL CONNECTORS SHALL HAVE CURRENT ICC-ES APPROVAL. ADDITIONAL TRUSSES SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. PER IBC SECTION 2303.4 AND TPI-1: EACH TRUSS SHALL BE LEGIBLY BRANDED, MARKED OR OTHERWISE HAVE PERMANENTLY AFFIXED THERETO THE IDENTITY OF THE COMPANY MANUFACTURING THE TRUSS, THE DESIGN LOADS, AND THE TRUSS SPACING - WITHIN TWO FEET OF THE CENTER OF THE SPAN ON THE FACE OF THE BOTTOM CHORD. REBAR DOWELING TO CONCRETE: FOUNDATION NOTES: 1.FOUNDATIONS DESIGNED IN CONFORMANCE WITH RECOMMENDATIONS BY: XCELL ENGINEERING, LLC. REPORT NO. P23292 DATED FEBRUARY 3, 2023. 2.SITE PREPARATION AND GRADING REQUIREMENTS OF THE SOIL REPORT AND ANY ADDENDUM'S SHALL BE COMPLETED PRIOR TO CONSTRUCTION OF FOUNDATIONS. ANY TESTS OR INSPECTIONS REQUIRED BY THE SOIL REPORT SHALL BE PERFORMED PRIOR TO PLACEMENT OF FOUNDATION REINFORCING STEEL OR CONCRETE. ALTERATIONS TO SITE PREPARATION OR GRADING SHALL BE REPORTED TO THE GEOTECHNICAL ENGINEER PRIOR TO FOUNDATION CONSTRUCTION. SOILS (IBC TABLE 1705.6) VERIFICATION AND INSPECTION CONTINUOUS SPECIAL INSPECTION PERIODIC SPECIAL INSPECTION 1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY.-X 2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL.-X 3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS.-X 4. DURING FILL PLACEMENT, VERIFY USE OF PROPER MATERIALS AND PROCEDURES IN ACCORDANCE WITH THE PROVISIONS OF THE APPROVED GEOTECHNICAL REPORT. VERIFY DENSITIES AND LIFT THICKNESS DURING PLACEMENT AND COMPACTION OF COMPACTED FILL. X - 5. PRIOR TO PLACEMENT OF COMPACTED FILL, INSPECT SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY. -X JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-494 PR E L I M I N A R Y NO T F O R CO N S T R U C T I O N 11 6 9 7 PRO F E S S I O N A L ENG I N E E R R E G I S TERE D S T ATE O F I D A H O M A R KEL L B A T E M A N MECHANICAL ENGINEERING ELECTRICAL ENGINEERING STRUCTURAL ENGINEERING 04 / 1 3 / 2 0 2 3 T8 TYPICAL REINFORCING DETAILS TD10 NO SCALE 6 MIN BAR OFFSET BAR CLEARANCE SPLICE DETAIL BEND & HOOK DETAILS COLUMN TIES BEAM STIRRUPS "d" 45° "d" "d" 1 8 8 KEYNOTES: 1.LAP - SEE G.S.N. FOR MASONRY AND TYPICAL DETAIL FOR CONCRETE 2.MAXIMUM 15 LAP BUT NOT MORE THAN 6" 3.WIRE TIES 4.1d (1" MINIMUM) 5.RADIUS = 3d FOR BARS NOT OVER #8; 4d FOR #9, #10, AND #11 BARS; 5d FOR #14 AND #18 BARS, 5d FOR ALL GRADE 40 BARS WITH 180 DEGREE HOOK 6.4D (4" MINIMUM) 7.12d (90 DEGREE HOOK) 8.6d (4" MINIMUM) 9.135 DEGREE BEND 10.BEND AROUND 112" PIN FOR #3 BARS. BEND AROUND 2" PIN FOR #4 BARS. BEND AROUND 212" PIN FOR #5 BARS. 3 1 2 4 6 7 5 55 5 99 10 10 6 8 NOTES: 1.TOP BARS ARE ANY HORIZONTAL BARS PLACED SO THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT. 2.UNLESS NOTED OTHERWISE, LAP SPLICES IN CONCRETE BEAMS, SLABS AND WALLS SHALL BE CLASS "B" TENSION LAP SPLICES. BAR SIZE CLASS B TENSION SPLICE LENGTHS f'c = 3,000 PSI f'c = 4,000 PSI f'c = 5,000 PSI HORIZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HORIZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HORIZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS #3 12"12"12"12"12"12" #4 19"15"17"13"15"12" #5 29"23"26"20"23"18" #6 32"25"28"21"25"19" #7 54"41"47"36"42"32" #8 70"54"61"47"54"42" #9 89"68"77"59"69"53" #10 112"87"97"75"87"67" T10 STEEL REINFORCING LAP SPLICES IN CONCRETE TD14 NO SCALE T11 TYPICAL PIPE THROUGH STEM WALL TD61 NO SCALE NOTE: A.NO PIPE SHALL PASS THROUGH FOOTINGS OR UNDER COLUMN FOOTINGS. FOR ADDITIONAL INFORMATION SEE PLANS AND DETAILS B.MULTIPLE PIPES/CONDUIT SLEEVES ALLOWED PROVIDED SLEEVES ARE SPACED W/ MINIMUM OF 2x SLEEVE DIAMETER BETWEEN SLEEVES C.SLEEVES SHALL NOT OCCUR WITHIN 12" OF POINT LOADS OR HOLDOWN ANCHORS 1' - 0 " MI N 1 7 3 4 5 6 22 KEYNOTES: 1.WALL AS OCCURS, SEE PLAN 2.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3.SLEEVE, 8"Ø MAX, PROVIDE 12" MINIMUM CLEARANCE AROUND PIPE-CONDUIT 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.PIPE OR CONDUIT KEYNOTES: 1.FINISHED GRADE WHERE OCCURS 2.DO NOT EXCAVATE A TRENCH CLOSER THAN A 45° ANGLE TO BELOW BOTTOM FOOTING OR FOUNDATION 3.BOTTOM OF CONCRETE FOOTING 4.BOTTOM OF TRENCH NOTE: A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPE OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T1 TRENCH PARALLEL TO CONTINUOUS STRIP FOOTING TD01 NO SCALE 1 1 4 3 2 1 KEYNOTES: 1.CONCRETE FOOTING 2.SLEEVE - PROVIDE 12" MINIMUM CLEARANCE AROUND PIPE OR CONDUIT 3.PIPE OR CONDUIT 4.CONCRETE FILL TO BE PLACED BEFORE FOOTING IS POURED - FORM SAME AS FOOTING AND POUR FULL WIDTH OF PIPE TRENCH 5.STEM WALL NOTE: A.NO PIPE SHALL PASS THRU FOOTING OR UNDER COLUMN FOOTINGS. FOR TRENCHES GREATER THAN 3'-6" BELOW BOTTOM OF FOOTING, SEE PIPE PASSING BELOW WALL FOOTING DETAIL. T2 PIPE PASSING UNDER WALL FOOTING IN SHALLOW TRENCH TD02 NO SCALE 6" M I N 8" M I N 3' - 0 " M A X 8" MIN A SECTIONA 5 1 2 3 4 5 1 2 3 4 KEYNOTES: 1.STEM WALL 2.CONCRETE FOOTING 3.1'-6" MAXIMUM (WHERE TRENCH EXCEEDS 1'-6" NOTIFY STRUCTURAL ENGINEER PRIOR TO PLACEMENT OF FOOTINGS) 4.BACKFILL AND RECOMPACT TRENCH PER SOILS REPORT AND SPECIFICATIONS 5.BOTTOM OF TRENCH NOTE: A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPES OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS 3' - 1 " O R G R E A T E R FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T3 PIPE PASSING BELOW FOOTING IN DEEP TRENCH TD03 NO SCALE 5 3 2 1 44 1 KEYNOTES: 1.SLOPED FINISH GRADE 2.MINIMUM FOOTING DEPTH PER G.S.N. (12" MINIMUM) 3.DEEPEN FOOTING AS REQUIRED TO ACCOUNT FOR SLOPED GRADE 4.CONCRETE FOOTING NOTE: A.FOR ADDITIONAL INFORMATION, SEE PLANS AND DETAILS 5'-0" T4 TYPICAL DETAIL FOR FOUNDATION EMBEDMENT TD04 NO SCALE 1 2 3 4 KEYNOTES: 1.CORNER DOWELS TO MATCH HORIZONTAL REINFORCEMENT 2.CONCRETE WALL WITH REINFORCEMENT 3.LAP SPLICE PER TYPICAL STEEL REINFORCING LAP SPLICES IN CONCRETE DETAIL T5 TYPICAL CONCRETE CORNER TD05 NO SCALE 2 1 3 3 KEYNOTES: 1.CONCRETE SLAB ON GRADE 2.CONT KEYED JOINT 3.SAWCUT 18" WIDE x 1 4 SLAB THICKNESS IN DEPTH - CUT SHALL BE MADE SOON ENOUGH TO PREVENT SHRINKAGE CRACKING, BUT NOT SO SOON AS TO CAUSE SPALLING OF THE CONCRETE WHILE SAWING. WORK MUST BE COMPLETE WITHIN 16 HOURS OF CONCRETE PLACEMENT. NOTE: A.KEYED JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING PLACEMENT UNLESS SPECIFICALLY NOTED ON THE PLANS. B."TOOL WET JOINT", "ZIP STRIP", ETC SHALL MATCH SAWCUT REQUIREMENTS 12"6"6"12" SAWCUT JOINT KEYED JOINT T7 CONTROL JOINTS IN CONCRETE SLAB ON GRADE TD07 NO SCALE 1 3 1 2 KEYNOTES: 1.MINIMUM LAP PER PLAN (24" MIN) - TYPICAL 2.TOP OF WALL FOOTING 3.REGULAR FOOTING THICKNESS AS SHOWN ON PLAN OR FOOTING SCHEDULE NOTE: A.D = 2'-0" MAX 2D 2D D D D 1D MIN 1D MIN 1D MIN 2D T6 TYPICAL STEP IN CONCRETE FOOTING TD08 NO SCALE 2 3 1 T12 TYPICAL CONCRETE STAIRS ON GRADE TD58 NO SCALE KEYNOTES: 1.CONCRETE STAIRS ON GRADE, SEE PLAN 2.#4 AT 18" O.C. 3.#4 AT 18" O.C. 4.#4 AT NOSE OF STEP 5.COMPACTED SUB-GRADE BELOW STAIRS 4" MIN 2" CLR 3 2 4 1 5 T14 PLAN VIEW - HOLDOWN LOCATIONS/SHEARWALL END POSTS, "HD" TYPE HOLDOWNS USING SCREWS TD16 NO SCALE NOTE: A.ALL CONDITIONS MAY NOT BE SHOWN. FOR CONDITIONS NOT SHOWN, USE THESE DETAILS AS A GUIDE. B.SOME LARGER HOLDOWNS REQUIRE 6x6 POSTS, SEE PLANS AND SCHEDULES. C.WHERE MULTIPLE TRIMMER STUDS OR KING STUDS OCCUR, MAKE ADJUSTMENTS AS REQUIRED. KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.SHEARWALL SHEATHING, SEE PLAN 3.EDGE OF FOUNDATION 4.SIMPSON HD TYPE HOLDOWN WITH SCREWS 5.SHEARWALL END POST (2 STUDS) TYPICAL, EXCEPT AT HDU11, AND HDU14 WHERE 6x6 POST IS REQUIRED 6.25) - SIMPSON SDS 1 4"x6" LONG WOOD SCREWS, STAGGERED 7.SHEARWALL EDGE NAILING 8.TRIMMER STUD TO SUPPORT HEADER 9.BLOCK TO SUPPORT WINDOW SILL 10.BUILT UP WOOD POST (2) SHEARWALLS (1) "HD" HOLDOWN W/SCREWS "HD" HOLDOWN W/SCREWS WINDOW JAMB X "HD" HOLDOWN W/SCREWS DOOR JAMB OR WALL END X HOLDOWN X HD19 2-1/8" 1-5/16"HDU2, HDU4, HDU5 HTT4 HTT5 1-5/16" (2) SHEARWALLS (1) "HD" HOLDOWN W/SCREWS AT EXTERIOR CORNER X (1) SHEARWALL (1) "HD" HOLDOWN W/SCREWS AT EXTERIOR CORNER X AT RE-ENTRANT CORNER X (1) SHEARWALL (1) "HD" HOLDOWN W/SCREWS AT RE-ENTRANT CORNER X 4 WINDOW OPENING DOOR OPENING HDU14 1-9/16" LTT20B LTT19 1-3/8" 1-1/2" HDU8, HDU11 1-3/8" 3 2 7 4 1 3 2 7 7 2 1 981 3 4 4 8 3 1 4 7 2 3 6 3 2 77 32 410 5 5 5 5 5 5 5 3 3 1 2 7 2 7 3 6 1 T13 TYPICAL ANCHORAGE FOR "HD" TYPE HOLDOWN TD56 NO SCALE 1 4" MAX 2" MI N EM B E D M E N T 2 4 3 KEYNOTES: 1.HOLDOWN ANCHOR BOLT 2.TOP OF CONCRETE OR COLD JOINT 3.DBL NUT AND 2"Ø PLATE WASHER 4.ADDITIONAL VERTICAL BAR(S), SEE SCHEDULE 5.TOP REINFORCING BAR (#4 BAR MINIMUM) PER PLAN 5 ANCHOR SCHEDULE ALL-THREAD ANCHOR DIAMETER MINIMUM EMBEDMENT MINIMUM VERTICAL BARS (PROVIDE ADDITIONAL VERTICAL BARS AS REQUIRED) ALTERNATE SIMPSON ANCHOR TYPE (INSTALL PER MANUFACTURER) 12"12"------ 5 8"16"(1) #5 OR (2) #4 SB5/8X24 7 8"18"(2) #5 SSTB34 OR SB7/8X24 1"20"(2) #6 SB1X30 T9 TYPICAL WOOD TRUSS AT NON-BEARING WALL TD74 NO SCALE KEYNOTES: 1.WOOD TRUSS 2.HTC4 CLIP AT WALL ENDS AND AT 48" O.C. (MAX) REMAINDER 3.DBL TOP PLATE AT NON-BEARING WALL NOTE: A.NAILS SHOULD NOT BE DRIVEN COMPLETELY FLUSH AGAINST THE CONNECTOR AT THE TRUSS TO ALLOW VERTICAL TRUSS MOVEMENT, ALLOW 116" GAP BETWEEN NAIL HEAD AND TRUSS CLIP B.ARCH TO PROVIDE FINISH TO ALLOW FOR 3 4" VERTICAL MOVEMENT OF TRUSS 1 2 3 3 4 " G A P M I N PR E L I M I N A R Y NO T F O R CO N S T R U C T I O N 11 6 9 7 PRO F E S S I O N A L ENG I N E E R R E G I S TERE D S T ATE O F I D A H O M A R KEL L B A T E M A N MECHANICAL ENGINEERING ELECTRICAL ENGINEERING STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-494 04 / 1 3 / 2 0 2 3 NOTE: A.MINIMUM STAPLING SPECIFIED HEREIN SHALL BE PROVIDED UNLESS NOTED OTHERWISE ON PLANS, DETAILS OR GENERAL STRUCTURAL NOTES 8d COMMON AT 12" O.C. 16 GA STAPLE AT 12" O.C. ALTERNATE FASTENER SCHEDULE ALTERNATE FASTENERSPECIFIED FASTENER 8d COMMON AT 6" O.C. 8d COMMON AT 4" O.C. 15 GA STAPLE AT 12" O.C. 14 GA STAPLE AT 12" O.C. 13 GA STAPLE AT 12" O.C. 16 GA STAPLE AT 4" O.C. 15 GA STAPLE AT 5" O.C. 14 GA STAPLE AT 6" O.C. 13 GA STAPLE AT 6" O.C. 13 GA STAPLE AT 5" O.C. 14 GA STAPLE AT 4" O.C. 15 GA STAPLE AT 3" O.C. 16 GA STAPLE AT 2.5" O.C. 15 GA STAPLE AT 2" O.C. 14 GA STAPLE AT 3" O.C. 13 GA STAPLE AT 4" O.C. 8d COMMON AT 3" O.C. MATERIAL: 7/16" SHEARWALL OR ROOF SHEATHING NOTES: 1.STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7 16" INCH OUTSIDE DIMENSION. AND INSTALLED WITH CROWN PARALLEL TO THE LONG DIMENSION OF FRAMING MEMBER. 2.FRAMING SHALL BE 3x OR WIDER WHEN NAIL SPACING IS LESS THAN 3 INCHES ON CENTER. 3.ALL STAPLES SHALL HAVE 11 2" LONG LEGS MINIMUM. 4.STAPLE SIZES AND SPACING PER REPORT NO. ICC-ESR-1539 T17 ALTERNATE SHEATHING STAPLE OPTION TD32 NO SCALE CONNECTION TYPE JOIST OR TRUSS BEARING ON SILL OR GIRDER BRIDGING TO JOIST SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL TOP PLATE TO STUD DOUBLE STUDS, FACE NAIL DOUBLE TOP PLATES CONTINUOUS HEADER TO STUD CEILING JOISTS, LAPS OVER PARTITIONS CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL RAFTER OR TRUSS TO PLATE BUILT-UP CORNER STUDS TOENAIL (4)-8d COMMON (2 1/2" x 0.131") NAILING (3)-8d COMMON (2 1/2" x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES TOENAIL EACH END(2)-3"x 0.131" NAILS (Gun Nail) (2)-3"x 14 GAUGE STAPLES 16d (3 1/2"x 0.135") AT 16" O.C. FACE NAIL 3"x 14 GAUGE STAPLES AT 12" O.C. 3"x 0.131" NAILS (Gun Nail) AT 8" O.C. END NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES SOLE PLATE TO STUD END NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES FACE NAIL 16d (3 1/2"x 0.135") AT 24" O.C. 3"x 14 GAUGE STAPLES AT 8" O.C. 3"x 0.131" NAILS (Gun Nail) AT 8" O.C. FACE NAIL 16d (3 1/2"x 0.135") AT 16" O.C. 3"x 14 GAUGE STAPLES AT 12" O.C. 3"x 0.131" NAILS (Gun Nail) AT 12" O.C. DOUBLE TOP PLATES - FACE NAIL (8)-16d COMMON (3 1/2"x 0.162") (12)-3"x 0.131" NAILS (Gun Nail) (12)-3"x 14 GAUGE STAPLES LAP SPLICE RIM JOIST TO TOP PLATE 8d (2 1/2"x 0.131") AT 6" O.C. 3"x 14 GAUGE STAPLES AT 6" O.C. 3"x 0.131" NAILS (Gun Nail) AT 6" O.C. BLOCKING BETWEEN JOISTS OR RAFTERS TOENAIL (3)-8d COMMON (2 1/2"x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES AND TOP PLATE TOENAIL TOP PLATES, LAPS AND INTERSECTIONS FACE NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES CONTINUOUS HEADER, TWO PIECES 16d COMMON (3 1/2"x 0.162") FACE NAIL AT 16" O.C. ALONG EDGES CEILING JOISTS TO PLATE TOENAIL (3)-8d COMMON (2 1/2"x 0.131") (5)-3"x 0.131" NAILS (Gun Nail) (5)-3"x 14 GAUGE STAPLES FACE NAIL (3)-16d COMMON (3 1/2"x 0.162) (4)-3"x 0.131" NAILS (Gun Nail) (4)-3"x 14 GAUGE STAPLES (3)-16d COMMON (3 1/2"x 0.162) (4)-3"x 0.131" NAILS (Gun Nail) (4)-3"x 14 GAUGE STAPLES FACE NAIL (3)-8d COMMON (2 1/2"x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES TOENAIL TOENAIL 16d COM.(3 1/2"x 0.162") AT 24" O.C. 3"x 14 GAUGE STAPLES AT 16" O.C. 3"x 0.131" NAILS (Gun Nail) AT 16" O.C.FACE NAIL (2)-8d COMMON (2 1/2" x 0.131") USE- SIMPSON A35 AT 48" O.C.-NA- SIMPSON A35 AT EVERY OTHER BLOCK -NA- NOTE: A.MINIMUM NAILING SPECIFIED HEREIN SHALL BE PROVIDED UNLESS NOTED OTHERWISE ON PLANS, DETAILS OR GENERAL STRUCTURAL NOTES B.NAILING NOT NOTED ON THESE PLANS OR DETAILS SHALL BE PER I.B.C. TABLE 2304.10.1 T18 MINIMUM NAILING SCHEDULE - UNLESS NOTED OTHERWISE TD34 NO SCALE T16 TYPICAL STRAP AT WOOD BEAM TD68 NO SCALE KEYNOTES: 1.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 2.TRIMMER AND KING STUDS, SEE PLAN 3.WOOD BEAM, SEE PLAN 4.STRAP, SEE PLAN3 4 2 1 1 3 4 2 1 2 3 OPTION 1 OPTION 2 OPTION 3 4 T19 ELEVATION-TYPICAL 1-STORY SHEARWALL TD19 NO SCALE KEYNOTES: 1.SHEATHING MATERIAL 2.DOUBLE STUDS AT EACH END OF SHEARWALL, EDGE NAIL ALONG DOUBLE STUDS 3.FULL HEIGHT WOOD STUDS 4.BOTTOM PLATE ATTACHMENT 5.SIMPSON STHD TYPE HOLDOWN 6.MIDHEIGHT BLOCKING AND EDGE NAILING REQUIRED 7.SIMPSON "HD" TYPE HOLDOWN 8.FINISHED FLOOR 9.CONT 2x PT SOLE PLATE 1 3 6 8 7 4 5 2 9 KEYNOTES: 1.NAILS BETWEEN SPLICE LOCATION PER SCHEDULE - STAGGERED 2.DBL 2x TOP PLATE 3.WOOD STUD WALL, SEE PLAN 4.SPLICE OVER STUD 5.SIMPSON ST6224 OR MSTC40 STRAP AT LOCATIONS WHERE PLATES CAN NOT BE SPLICED NOTE: A.DO NOT SPLICE TOP PLATES WITHIN 6'-0" OF ENDS OF PLYWOOD SHEARWALLS. THIS DETAIL REQUIRED AT ALL EXTERIOR WALLS AND OVER SHEARWALLS - NOT REQUIRED AT INTERIOR NON-SHEARWALLS. (40) 16d (24) 16dLESS THAN 20' OVER 20' 4'-0" 6'-0" LENGTH OF WALL (BETWEEN CORNERS)SPLICE LENGTH NAILS ALONGSPLICE LENGTH MINIMUM SPLICE LENGTH PER SCHEDULE T20 ELEVATION - TYPICAL TOP PLATE SPLICE TD24 NO SCALE 4 5 1 3 2 3 2 KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.WOOD HEADER 3.KING STUD(S) PER PLAN 4.(2) 16d NAILS AT 2" O.C. 5.16d NAILS AT 12" O.C. 6.TRIMMER STUD(S) PER PLAN 2 6 3 1 5 4 5 T15 TYPICAL HEADER CONNECTION TD25 NO SCALET21TYPICAL WALL PENETRATION LESS THAN 10" SQUARE AT SHEARWALL TD78 NO SCALE KEYNOTES: 1.SHEATHING MATERIAL 2.WOOD STUD WALL 3.5" TO 10" SQUARE OPENING, PROVIDE FULL DEPTH BLOCKING ON SIDE, TOP AND BOTTOM W/ EDGE NAILING 4.EDGE NAILING 5.5" OR SMALLER SQUARE OPENING, NO BLOCKING W/ EDGE NAILING REQUIRED 1 2 444 3 5 NOTES: 1.MAXIMUM ACCUMULATED LENGTH OF OPENINGS SHALL NOT EXCEED 10% OF WALL LENGTH. NOTES: 1.ANGLES ARE TO BE HOT DIPPED GALVANIZED. 2.LINTELS CARRY BRICK OR STONE ONLY. WHERE FLOORS, ROOFS, OR CONCENTRATED LOADS OCCUR ABOVE, FURTHER ANALYSIS IS NECESSARY. 3.PROVIDE 1" OF BEARING EACH END FOR EACH FOOT OF SPAN (6" BEARING EACH SIDE OF OPENING MINIMUM). 4.USE THIS SCHEDULE UNLESS NOTED OTHERWISE T22 BRICK VENEER STEEL ANGLE LINTEL TD55 NO SCALE BRICK VENEER STEEL ANGLE LINTEL SCHEDULE OPENING WIDTH ANGLE SIZE UP TO 7'-0"L31 2x312x14 7'-1" TO 9'-0"L5x31 2x14 (LLV) 9'-1" TO 10'-0"L5x312x5 16 (LLV) 10'-1" TO 11'-0"L5x312x3 8 (LLV) 11'-1" TO 12'-0"L6x4x3 8 (LLV) 12'-1" AND OVER SPECIAL ANALYSIS REQUIRED 4" T23 TYPICAL ROOF SNOW SURCHARGE / DRIFT LOAD TD73 NO SCALE KEYNOTES: 1.SURCHARGE OR DRIFT SNOW LOAD AREA, SEE PLAN 2.BALANCED ROOF SNOW LOAD, SEE GSN 3.REQUIRED LOAD INCREASE, SEE PLAN 4.EXTENT OF SURCHARGE OR DRIFT LOAD, SEE PLAN NOTE: A.SURCHARGE AND DRIFT LOADS ARE IN ADDITION TO ROOF BALANCED SNOW LOAD ##PSF ##PSF 3 3 1 2 4 PR E L I M I N A R Y NO T F O R CO N S T R U C T I O N 11 6 9 7 PRO F E S S I O N A L ENG I N E E R R E G I S TERE D S T ATE O F I D A H O M A R KEL L B A T E M A N MECHANICAL ENGINEERING ELECTRICAL ENGINEERING STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-494 04 / 1 3 / 2 0 2 3 EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING 4" CONCRETE SLAB ON GRADE W/ #3 AT 18" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME T.O. SLAB ELEVATION = 100'-0" CONCRETE SLAB ON GRADE 4" CONCRETE SLAB ON GRADE W/ #3 AT 18" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME T.O. SLAB ELEVATION = 98'-0" CONCRETE SLAB ON GRADE WF18 / W1 1 F48 1 1 WF18 / W1 WF 1 8 / W 1 WF24 / W2 WF 1 8 / W 1 2 2 1 WF24 WF24 WF24 / W2 WF 2 4 / W 2 WF18 / W1 WF 2 4 / W 2 WF24 / W2 F36 2 2 1 4 A A A A A A 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 F36 F36 F36 WF 1 8 / W 3 WF 1 8 / W 3 WF 1 8 / W 3 5 55 6. WF 1 6 WF16 WF 1 6 WF16 A A 4" CONCRETE SLAB ON GRADE W/ #3 AT 18" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME T.O. SLAB ELEVATION = 100'-0" CONCRETE SLAB ON GRADE 3 3 F36 F36 F36 2 2 2 2'-0" MIN 2' - 0 " MI N 47 ' - 3 " 95'-4" 1'-41 2"6'-3"1'-5"6'-3"80'-01 2" 6' - 4 3 4" 156'-91 2" 77 ' - 4 3 4" 36 ' - 5 1 4" 6' - 3 " 34 ' - 8 1 2" 50'-5"10'-0"79'-5"6'-31 2"1'-1" T.O.F. 97'-8" 5 T.O.F. 99'-8" 5 T.O.F. 97'-8" T.O.F. 97'-8" T.O.F. 97'-8" 6'-4"3'-3" 34 ' - 5 1 2" 10 ' - 0 " 32 ' - 1 1 1 4" 8'-6"78'-31 2"5'-4"4'-8"33'-4" 10'-10"4'-8"44'-6" 7' - 6 3 4" 11 ' - 4 3 4" 15 ' - 6 " 1' - 8 1 2" 6' - 3 " 2' - 3 1 4" 4 WF24 WF24 WF24WF24 A A WF18 / W1 102 102 102 101 102 101 102 103 103 102 101 101 101 101 105 104 106 SIM 105 107 108 WF 1 8 / W 3 WF 2 4 / W 2 F48 4' - 0 " 4'-0" 26'-8" WF 1 8 / W 3 WF18 / W3 2 SIM 105 109 4" CONCRETE SLAB ON GRADE W/ #3 AT 18" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME T.O. SLAB ELEVATION = 98'-0" CONCRETE SLAB ON GRADE T.O.F. 97'-8" SIM 105 SCALE: FOUNDATION PLAN - OVERALL 1" = 20' PR E L I M I N A R Y NO T F O R CO N S T R U C T I O N 11 6 9 7 PRO F E S S I O N A L ENG I N E E R R E G I S TERE D S T ATE O F I D A H O M A R KEL L B A T E M A N MECHANICAL ENGINEERING ELECTRICAL ENGINEERING STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-494 04 / 1 3 / 2 0 2 3 EXISTING BUILDING EXISTING BUILDING 4" CONCRETE SLAB ON GRADE W/ #3 AT 18" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME T.O. SLAB ELEVATION = 100'-0" CONCRETE SLAB ON GRADE WF24 WF24 WF24 / W2 WF 2 4 / W 2 WF18 / W1 WF 2 4 / W 2 WF24 / W2 F36 2 2 1 4 A A A A A A 5 5 5 5 5 5 5 5 5 5 5 F36 F36 F36 WF 1 8 / W 3 WF 1 8 / W 3 WF 1 8 / W 3 6. WF 1 6 WF16 WF 1 6 WF16 4" CONCRETE SLAB ON GRADE W/ #3 AT 18" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME T.O. SLAB ELEVATION = 100'-0" CONCRETE SLAB ON GRADE 3 3 F36 F36 F36 2 2 2 156'-91 2" 77 ' - 4 3 4" 36 ' - 5 1 4" 6' - 3 " 34 ' - 8 1 2" 50'-5"10'-0"79'-5"6'-31 2"1'-1" T.O.F. 97'-8" 5 T.O.F. 99'-8" 5 T.O.F. 97'-8" T.O.F. 97'-8" T.O.F. 97'-8" 6'-4"3'-3" 34 ' - 5 1 2" 10 ' - 0 " 32 ' - 1 1 1 4" 8'-6"78'-31 2"5'-4"4'-8"33'-4" 10'-10"4'-8"44'-6" 7' - 6 3 4" 11 ' - 4 3 4" 15 ' - 6 " 1' - 8 1 2" 6' - 3 " 2' - 3 1 4" 4 WF24 WF24 WF24WF24 A A WF18 / W1 102 103 103 102 101 101 101 101 105 104 106 SIM 105 107 108 WF 1 8 / W 3 26'-8" WF 1 8 / W 3 WF18 / W3 2 SIM 105 109 4" CONCRETE SLAB ON GRADE W/ #3 AT 18" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME T.O. SLAB ELEVATION = 98'-0" CONCRETE SLAB ON GRADE T.O.F. 97'-8" SIM 105 SCALE: FOUNDATION PLAN - AREA A 1/8" = 1'-0" PR E L I M I N A R Y NO T F O R CO N S T R U C T I O N 11 6 9 7 PRO F E S S I O N A L ENG I N E E R R E G I S T ERE D S T ATE O F I D A H O M A R KEL L B A T E M A N MECHANICAL ENGINEERING ELECTRICAL ENGINEERING STRUCTURAL ENGINEERING WALL (W) SCHEDULE MARK THICKNESS AND TYPE VERTICAL REINFORCING HORIZONTAL REINFORCING REMARKS W1 8" CONCRETE #4 AT 18" O.C.#4 AT 12" O.C.--- W2 10" CONCRETE #4 AT 18" O.C.#4 AT 10" O.C.--- W3 6" CONCRETE #4 AT 18" O.C.#4 AT 18" O.C.--- FOOTING SCHEDULE NOTES: 1. FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. 2. FOR MINIMUM CLEARANCE (CLR) OF REINFORCING, SEE GENERAL STRUCTURAL NOTES (GSN). MARK LENGTH WIDTH THICK- NESS FOOTING REINFORCING REMARKS F36 36"36"10"(4) #4 EACH WAY BOTTOM --- F48 48"24"10" (4) #4 BARS DRILLED AND EPOXIED PERPENDICULAR INTO THE EXISTING FOOTING, W/ (2) #4 BARS PARALLEL W/ THE EXISTING FOOTING 8" MIN EMBED OF EPOXIED BARS INTO EXISTING FOOTING WF16 CONT 16"6"(2) #4 CONT BOTTOM --- WF18 CONT 18"10"(2) #4 CONT BOTTOM --- WF24 CONT 24"10"(3) #4 CONT BOTTOM --- A.VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B.ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C.THE DEPTH OF FOOTING DIMENSION INDICATED IN THE G.S.N. IS A MINIMUM. FOUNDATION CONTRACTOR SHALL COORDINATE WITH THE SOILS REPORT AND OTHER TRADES TO INSURE THAT THESE MINIMUMS ARE SUFFICIENT FOR THE WORK. SEE TYPICAL DETAILS FOR ADDITIONAL REQUIREMENTS. D. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. E. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. F. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. G. , , - AS SHOWN ON PLAN INDICATES A SHEARWALL HOLDOWN. SEE HOLDOWN SCHEDULES AND DETAILS FOR ADDITIONAL INFORMATION. H.W1, W2, ETC. - AS SHOWN ON PLAN INDICATES CONCRETE OR MASONRY WALLS. SEE WALL SCHEDULE FOR ADDITIONAL INFORMATION. I.WF18, WF24, ETC. - AS SHOWN ON PLAN INDICATES A CONTINUOUS WALL FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. J.F36, F48, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. K.P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. L.ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. M.T.O. INTERIOR FOOTING, UNO: 99'-8" FOUNDATION PLAN NOTES 5 6.7 A B SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 4" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 24" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 32" O.C. WOOD:16d STAGGERED AT 4" O.C. 5 6. 1.DRILL AND EPOXY NEW FOOTING TO EXISTING FOOTING W/ 18" LONG #4 DOWELS AT 36" O.C. PROVIDE 6" MIN EMBEDMENT 2.DRILL AND EPOXY HORIZONTAL FOOTINGS AND WALL REINFORCEMENT INTO THE EXISTING FOUNDATIONS W/ 6" MIN EMBEDMENT 3.SLAB STEPS ON GRADE PER ARCH, SEE TYPICAL DETAIL FOR CONSTRUCTION INFORMATION 4.TIE NEW SLAB INTO EXISTING WALL/SLAB W/ #3 BARS AT 48" O.C., PROVIDE 4" MIN EMBEDMENT 5.STEP FOOTING AS REQUIRED, SEE TYPICAL STEP IN CONCRETE FOOTING DETAIL PLAN KEYNOTESX SHEARWALL HOLDOWN SCHEDULE NOTES: 1. SEE TYPICAL DETAILS FOR ANCHOR BOLT EMBEDMENT REQUIREMENTS. 2. POSTS SHOWN ON THE PLANS AR A MINIMUM AS REQUIRED TO SUPPORT THE GRAVITY LOADS OF THE STRUCTURE. ADDITIONAL STUDS OR SOLID POSTS MAY BE REQUIRED DEPENDENT ON HOLDOWN TYPES. MARK HOLDOWN SHEARWALL END POST UNO ON PLAN ALTERNATE HOLDOWN ANCHOR BOLT DIA. HTT4 W/ (18) 0.162 x 2.5" NAILS (2) 2x STUDS SIMPSON STHD14 5 8"A JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-494 04 / 1 3 / 2 0 2 3 EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING 4" CONCRETE SLAB ON GRADE W/ #3 AT 18" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME T.O. SLAB ELEVATION = 98'-0" CONCRETE SLAB ON GRADE WF18 / W1 1 F48 1 1 WF18 / W1 WF 1 8 / W 1 WF24 / W2 WF 1 8 / W 1 2 2 1 5 5 5 5 5 5 55 A A 2'-0" MIN 2' - 0 " MI N 47 ' - 3 " 95'-4" 1'-41 2"6'-3"1'-5"6'-3"80'-01 2" 6' - 4 3 4" 102 102 102 101 102 101 WF 2 4 / W 2 F48 4' - 0 " 4'-0" SCALE: FOUNDATION PLAN - AREA B 1/8" = 1'-0" PR E L I M I N A R Y NO T F O R CO N S T R U C T I O N 11 6 9 7 PRO F E S S I O N A L ENG I N E E R R E G I S T ERE D S T ATE O F I D A H O M A R KEL L B A T E M A N MECHANICAL ENGINEERING ELECTRICAL ENGINEERING STRUCTURAL ENGINEERING WALL (W) SCHEDULE MARK THICKNESS AND TYPE VERTICAL REINFORCING HORIZONTAL REINFORCING REMARKS W1 8" CONCRETE #4 AT 18" O.C.#4 AT 12" O.C.--- W2 10" CONCRETE #4 AT 18" O.C.#4 AT 10" O.C.--- W3 6" CONCRETE #4 AT 18" O.C.#4 AT 18" O.C.--- FOOTING SCHEDULE NOTES: 1. FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. 2. FOR MINIMUM CLEARANCE (CLR) OF REINFORCING, SEE GENERAL STRUCTURAL NOTES (GSN). MARK LENGTH WIDTH THICK- NESS FOOTING REINFORCING REMARKS F36 36"36"10"(4) #4 EACH WAY BOTTOM --- F48 48"24"10" (4) #4 BARS DRILLED AND EPOXIED PERPENDICULAR INTO THE EXISTING FOOTING, W/ (2) #4 BARS PARALLEL W/ THE EXISTING FOOTING 8" MIN EMBED OF EPOXIED BARS INTO EXISTING FOOTING WF16 CONT 16"6"(2) #4 CONT BOTTOM --- WF18 CONT 18"10"(2) #4 CONT BOTTOM --- WF24 CONT 24"10"(3) #4 CONT BOTTOM --- 1.DRILL AND EPOXY NEW FOOTING TO EXISTING FOOTING W/ 18" LONG #4 DOWELS AT 36" O.C. PROVIDE 6" MIN EMBEDMENT 2.DRILL AND EPOXY HORIZONTAL FOOTINGS AND WALL REINFORCEMENT INTO THE EXISTING FOUNDATIONS W/ 6" MIN EMBEDMENT PLAN KEYNOTESX A.VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B.ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C.THE DEPTH OF FOOTING DIMENSION INDICATED IN THE G.S.N. IS A MINIMUM. FOUNDATION CONTRACTOR SHALL COORDINATE WITH THE SOILS REPORT AND OTHER TRADES TO INSURE THAT THESE MINIMUMS ARE SUFFICIENT FOR THE WORK. SEE TYPICAL DETAILS FOR ADDITIONAL REQUIREMENTS. D. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. E. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. F. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. G. , , - AS SHOWN ON PLAN INDICATES A SHEARWALL HOLDOWN. SEE HOLDOWN SCHEDULES AND DETAILS FOR ADDITIONAL INFORMATION. H.W1, W2, ETC. - AS SHOWN ON PLAN INDICATES CONCRETE OR MASONRY WALLS. SEE WALL SCHEDULE FOR ADDITIONAL INFORMATION. I.WF18, WF24, ETC. - AS SHOWN ON PLAN INDICATES A CONTINUOUS WALL FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. J.F36, F48, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. K.P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. L.ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. M.T.O. INTERIOR FOOTING, UNO: 99'-8" FOUNDATION PLAN NOTES 5 6.7 A B SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 4" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 24" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 32" O.C. WOOD:16d STAGGERED AT 4" O.C. 5 6. SHEARWALL HOLDOWN SCHEDULE NOTES: 1. SEE TYPICAL DETAILS FOR ANCHOR BOLT EMBEDMENT REQUIREMENTS. 2. POSTS SHOWN ON THE PLANS AR A MINIMUM AS REQUIRED TO SUPPORT THE GRAVITY LOADS OF THE STRUCTURE. ADDITIONAL STUDS OR SOLID POSTS MAY BE REQUIRED DEPENDENT ON HOLDOWN TYPES. MARK HOLDOWN SHEARWALL END POST UNO ON PLAN ALTERNATE HOLDOWN ANCHOR BOLT DIA. HTT4 W/ (18) 0.162 x 2.5" NAILS (2) 2x STUDS SIMPSON STHD14 5 8"A JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-494 04 / 1 3 / 2 0 2 3 EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING 5 5 5 5 5 1 P1 (3) KS P1 (3) KS P2 P2 (E) PREFAB WOOD TRUSS AT 24" O.C. PREFAB WOOD TRUSS AT 24" O.C. P1 (2) KS P1 (2) KS P1 (2) KS P1 (2) KS P1 (2) KS P1 (2) KS P1 (2) KS P1 (2) KS P2 P2 P1 P1 P2 P2 5 5 5 5 5 5 P1 (2) KS P1 (2) KS P1 P1 P1 P1 5 5 5 P1 P1 P1 P1 (2) KS (2) KS (2) KS (2) KS P1 (3) KS P1 (3) KS P1 (3) KS P1 (3) KS 19/32" APA RATED ROOF SHEATHING W/ 10d COMMON NAILS AT 6" O.C. AT PANEL EDGES / BOUNDARY AND AT 12" O.C. IN THE FIELD. TYPICAL ROOF SHEATHING: 19/32" APA RATED ROOF SHEATHING W/ 10d COMMON NAILS AT 6" O.C. AT PANEL EDGES / BOUNDARY AND AT 12" O.C. IN THE FIELD. TYPICAL ROOF SHEATHING: (3) KS (3) KS (2) KS (2) KS RME 1,500# RME 1,500# RME 1,500# RME 1,500# RME 1,500# RME 1,500# RME 1,500# 5 PREFAB WOOD TRUSS AT 24" O.C. RME 1,500# RME 1,500# 5 GT GT GT GT OPEN PREFAB WOOD TRUSS AT 24" O.C. RME 3,500# 5 55 P1 P1 P1P1 6. D = 1 3 , 0 0 0 # 2 TYP2TYP2TYP 3 TYP B3 B3 B5 B5 B5 B2 B7 B3 B6B4 B4 B4 B4 B4 B4 B2 B4 B6 B6 B1 B2 B6 B3 B3 B3 B6 B3 B5 B5 BX 3 TYP 2 204 204 202 201 203 207 209 209 202 202 202 205 205 206 205 205 208 208 205 205 205 206 206 206206 209 211 210 207 16'-0" 85 PSF 0 PSF 4203 5 204209 4 JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-494 SCALE: ROOF FRAMING PLAN - OVERALL 1" = 20' PR E L I M I N A R Y NO T F O R CO N S T R U C T I O N 11 6 9 7 PRO F E S S I O N A L ENG I N E E R R E G I S TERE D S T ATE O F I D A H O M A R KEL L B A T E M A N MECHANICAL ENGINEERING ELECTRICAL ENGINEERING STRUCTURAL ENGINEERING 04 / 1 3 / 2 0 2 3 EXISTING BUILDING EXISTING BUILDING PREFAB WOOD TRUSS AT 24" O.C. P1 (2) KS P1 (2) KS P1 (2) KS P1 (2) KS P1 (2) KS P1 (2) KS P1 (2) KS P1 (2) KS P2 P2 P1 P1 P2 P2 5 5 5 5 5 5 P1 (2) KS P1 (2) KS P1 P1 P1 P1 5 5 5 P1 P1 P1 P1 19/32" APA RATED ROOF SHEATHING W/ 10d COMMON NAILS AT 6" O.C. AT PANEL EDGES / BOUNDARY AND AT 12" O.C. IN THE FIELD. TYPICAL ROOF SHEATHING: (3) KS (3) KS (2) KS (2) KS RME 1,500# RME 1,500# RME 1,500# RME 1,500# RME 1,500# RME 1,500# RME 1,500# 5 PREFAB WOOD TRUSS AT 24" O.C. RME 1,500# RME 1,500# 5 GT GT GT GT OPEN 6. D = 1 3 , 0 0 0 # 2 TYP2TYP2TYP 3 TYP B3 B6B4 B4 B4 B4 B4 B4 B2 B4 B6 B6 B1 B2 B6 B3 B3 B3 B6 B3 BX 209 209 202 202 202 205 205 206 205 205 208 208 205 205 205 206 206 206206 209 211 210 207 204209 4 JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-494 SCALE: ROOF FRAMING PLAN - AREA A 1/8" = 1'-0" PR E L I M I N A R Y NO T F O R CO N S T R U C T I O N 11 6 9 7 PRO F E S S I O N A L ENG I N E E R R E G I S T ERE D S T ATE O F I D A H O M A R KEL L B A T E M A N SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 4" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 24" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 32" O.C. WOOD:16d STAGGERED AT 4" O.C. 5 6. BEAM (B) SCHEDULE MARK SIZE B1 (2) 2x6 OR 4x6 OR (2) 13 4x512 LVL B2 (2) 2x10 OR 4x10 OR (2) 13 4x714 LVL B3 (2) 13 4x912 LVL OR 518x712 GLB B4 (2) 13 4x117 8 LVL OR 518x1012 GLB B5 (3) 13 4x117 8 LVL OR 518x12 GLB B6 (3) 13 4x14 LVL OR 518x15 GLB B7 518x2212 GLB POST (P) SCHEDULE NOTES: 1. FOR CONNECTIONS AT EITHER END OF POST, SEE DETAILS. 2. UNO, SEE GENERAL STRUCTURAL NOTES (GSN) FOR LUMBER SPECIES AND GRADE. MARK SIZE SPECIES AND GRADE CONNECTION P1 (2) 2x6 DOUG FIR NO. 2 SEE TYPICAL DETAILS P2 (3) 2x6 DOUG FIR NO. 2 SEE TYPICAL DETAILS 1.ALIGN ADDITIONAL DRAG TRUSS W/ SHEARWALL BELOW, ATTACH TO SHEARWALL W/ HGA10KT CLIPS AT 3'-0" O.C. 2.PROVIDE 4x6 BLOCKING W/ HUS46TF HANGER EACH END BELOW PERIMETER OF RME AND ROOF PENETRATIONS. TRUSS MANUFACTURER SHALL DESIGN TRUSSES FOR THE ADDITIONAL RME WEIGHT SHOWN (ASD) 3.ROOF DRAINS, SEE ARCH FOR SIZE AND LOCATION 4.REFER TO ARCH DRAWINGS FOR REQUIRED LAYERS OF GYP BOARD FOR FIREWALL FRAMING. PLAN KEYNOTESX ROOF FRAMING PLAN NOTES A.VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B.ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C.IF DOUBLE TOP PLATE IS NOTCHED, STEPPED OR BROKEN, PROVIDE A SIMPSON MSTC40 STRAP AT DISCONTINUITY. D.TYPICAL BEARING WALL FRAMING SHALL BE 112"x512" LSL STUDS AT 16" O.C. UNO. E.PROVIDE TRIMMER STUDS (TS) AND KING STUDS (KS) AT OPENINGS AS FOLLOWS, U.N.O.: OPENINGS 6'-6" OR LESS, (1) TS & (1) KS, OPENINGS 6'-7" TO 10'-6", (2) TS & (2) KS. FOR ATTACHMENT, SEE "TYPICAL HEADER CONNECTION" DETAIL. F. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. G. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. H. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. I.B1, B2, ETC. - AS SHOWN ON PLAN INDICATES A BEAM OR HEADER. SEE BEAM SCHEDULE FOR ADDITIONAL INFORMATION. J.WJ1, WJ2, ETC. - AS SHOWN ON PLAN INDICATES A JOIST. SEE JOIST SCHEDULE FOR ADDITIONAL INFORMATION. K.P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. L.FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING CONDITION. M.ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. 5 6.7 04 / 1 3 / 2 0 2 3 EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING 5 5 5 5 5 1 P1 (3) KS P1 (3) KS P2 P2 (E) PREFAB WOOD TRUSS AT 24" O.C. (2) KS (2) KS (2) KS (2) KS P1 (3) KS P1 (3) KS P1 (3) KS P1 (3) KS 19/32" APA RATED ROOF SHEATHING W/ 10d COMMON NAILS AT 6" O.C. AT PANEL EDGES / BOUNDARY AND AT 12" O.C. IN THE FIELD. TYPICAL ROOF SHEATHING: PREFAB WOOD TRUSS AT 24" O.C. RME 3,500# 5 55 P1 P1 P1P1 B3 B3 B5 B5 B5 B2 B7 B5 B5 3 TYP 2 204 204 202 201 203 207 16'-0" 85 PSF 0 PSF4203 5 JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-494 SCALE: ROOF FRAMING PLAN - AREA B 1/8" = 1'-0" PR E L I M I N A R Y NO T F O R CO N S T R U C T I O N 11 6 9 7 PRO F E S S I O N A L ENG I N E E R R E G I S T ERE D S T ATE O F I D A H O M A R KEL L B A T E M A N SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 4" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 24" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 32" O.C. WOOD:16d STAGGERED AT 4" O.C. 5 6. BEAM (B) SCHEDULE MARK SIZE B1 (2) 2x6 OR 4x6 OR (2) 13 4x512 LVL B2 (2) 2x10 OR 4x10 OR (2) 13 4x714 LVL B3 (2) 13 4x912 LVL OR 518x712 GLB B4 (2) 13 4x117 8 LVL OR 518x1012 GLB B5 (3) 13 4x117 8 LVL OR 518x12 GLB B6 (3) 13 4x14 LVL OR 518x15 GLB B7 518x2212 GLB 1.STRAP BEAM TO TOP PLATE W/ MSTC40 STRAP PER "TYPICAL STRAP AT WOOD BEAM" OPTION 3, INSTALL STRAP PRIOR TO SETTING TRUSSES 2.PROVIDE 4x6 BLOCKING W/ HUS46TF HANGER EACH END BELOW PERIMETER OF RME AND ROOF PENETRATIONS. TRUSS MANUFACTURER SHALL DESIGN TRUSSES FOR THE ADDITIONAL RME WEIGHT SHOWN (ASD) 3.ROOF DRAINS, SEE ARCH FOR SIZE AND LOCATION 4.IN ADDITION TO REGULAR ROOF SNOW LOAD, TRUSS MANUFACTURER TO DESIGN TRUSSES FOR DRIFTING SNOW LOAD FOR LENGTH AND MAGNITUDE SHOWN, SEE TYPICAL DETAIL. 5.PROVIDE TRUSSES AT 16" O.C. FOR FIRST 8' FROM WALL PLAN KEYNOTESX POST (P) SCHEDULE NOTES: 1. FOR CONNECTIONS AT EITHER END OF POST, SEE DETAILS. 2. UNO, SEE GENERAL STRUCTURAL NOTES (GSN) FOR LUMBER SPECIES AND GRADE. MARK SIZE SPECIES AND GRADE CONNECTION P1 (2) 2x6 DOUG FIR NO. 2 SEE TYPICAL DETAILS P2 (3) 2x6 DOUG FIR NO. 2 SEE TYPICAL DETAILS ROOF FRAMING PLAN NOTES A.VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B.ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C.IF DOUBLE TOP PLATE IS NOTCHED, STEPPED OR BROKEN, PROVIDE A SIMPSON MSTC40 STRAP AT DISCONTINUITY. D.TYPICAL BEARING WALL FRAMING SHALL BE 112"x512" LSL STUDS AT 16" O.C. UNO. E.PROVIDE TRIMMER STUDS (TS) AND KING STUDS (KS) AT OPENINGS AS FOLLOWS, U.N.O.: OPENINGS 4'-0" OR LESS, (1) TS & (1) KS, OPENINGS 4'-1" TO 8'-6", (2) TS & (2) KS. FOR ATTACHMENT, SEE "TYPICAL HEADER CONNECTION" DETAIL. F. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. G. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. H. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. I.B1, B2, ETC. - AS SHOWN ON PLAN INDICATES A BEAM OR HEADER. SEE BEAM SCHEDULE FOR ADDITIONAL INFORMATION. J.WJ1, WJ2, ETC. - AS SHOWN ON PLAN INDICATES A JOIST. SEE JOIST SCHEDULE FOR ADDITIONAL INFORMATION. K.P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. L.FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING CONDITION. M.ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. 5 6.7 04 / 1 3 / 2 0 2 3 101 WOOD STUD WALL AT FOUNDATION CW_S125 NO SCALE KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ ANCHOR BOLTS PER SHEARWALL SCHEDULE 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.MINIMUM FOOTING DEPTH, SEE GSN 8.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 9.EDGE NAILING, SEE SHEARWALL SCHEDULE 10.WALL SHEATHING AS OCCURS, SEE PLAN 11.BRICK VENEER PER ARCH, ATTACH PER GSN NOTES: A.ALL WOOD WITHIN 8" OF FINISH GRADE SHALL BE PRESERVATIVE TREATED LUMBER (INCLUDING SHEATHING) AND BE WATERPROOFED PRE ARCHITECTURAL REQUIREMENTS, SEE ARCH DRAWINGS3" CLR 3" CL R 8 10 7 9 6 1 2 5 4 3 11 102 WOOD STUD WALL AT FOUNDATION NO SCALE 3" CLR 3" CL R 7 1 2 5 4 3 KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x4 PT SOLE PLATE W/ ANCHOR BOLTS PER SHEARWALL SCHEDULE 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.EXISTING FOUNDATION SYSTEM 8.EPOXY DOWELS, SEE PLAN 9.WALL SHEATHING AS OCCURS, SEE PLAN 10.EDGE NAILING, SEE SHEARWALL SCHEDULE 11.PROVIDE 2"x4" BLOCK-OUT AT TOP OF STEM WALL 12.VERTICAL WALL EPOXY DOWELS, SEE PLAN 12 10 9 6" MIN 11 6 6" MI N 8 FOOTING WIDTH SEE PLAN 103 WOOD STUD WALL AT FOUNDATION NO SCALE KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ O.145"Ø MIN SHOT PIN AT 32" O.C. 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE FOOTING, SEE PLAN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN NOTES: A.CONTINUOUS FOOTING CAN BE POURED MONOLITHICALLY W/ SLAB AT CONTRACTORS OPTION 1 2 3" CLR 3" CL R 5 4 3 104 WOOD STUD WALL AT FOUNDATION NO SCALE KEYNOTES: 1.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 2.CONCRETE FOOTING, SEE PLAN 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONT 2x PT SOLE PLATE W/ TITEN-HD ANCHORS. MATCH DIAMETER AND SPACING W/ SHEARWALL SCHEDULE 5.WOOD STUD WALL, SEE PLAN 6.WALL SHEATHING AS OCCURS, SEE PLAN 7.EDGE NAILING, SEE SHEARWALL SCHEDULE 8.#4 BENT DOWEL AT 36" O.C. 312" MI N 10" 10"6 7 5 4 8 NOTES: A.CONTINUOUS FOOTING CAN BE POURED MONOLITHICALLY W/ SLAB AT CONTRACTORS OPTION 3" CLR 3" CL R 1 2 3 107 CONCRETE SLAB AT FOUNDATION CW_S104 NO SCALE 3" CLR 3" CL R 8 7 6 8 5 4 3 1 2 KEYNOTES: 1.WALL BEYOND, SEE PLAN 2.#4 BENT DOWEL AT 18" O.C. 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.MINIMUM FOOTING DEPTH, SEE GSN 8.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 18" 18" 105 WOOD STUD WALL AT FOUNDATION NO SCALE 3" CLR 3" CL R 8 7 3 1 2 5 4 3 KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ ANCHOR BOLTS PER SHEARWALL SCHEDULE 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.EDGE NAILING, SEE SHEARWALL SCHEDULE 8.WALL SHEATHING AS OCCURS, SEE PLAN NOTES: A.AT SIM, NO SHEARWALL SHEATHING 6 106 MASONRY WALL AT FOUNDATION NO SCALE 3" CLR 3" CL R 2 1 4 3 5 6" MI N KEYNOTES: 1.8" MASONRY WALL W/ #4 VERT AT 48" O.C. AND #4 HORIZ AT 48" O.C. AND AT TOP OF WALL 2.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE FOOTING, SEE PLAN 5.DOWEL TO MATCH VERTICAL MASONRY WALL REINFORCING SIZE AND SPACING, EPOXY DOWEL AT FOOTING 24 " M I N L A P SEE PLAN 8" MI N 2' - 0 " M A X 108 CONCRETE SLAB AT FOUNDATION NO SCALE 3" CLR 3" CL R 3 1 4 3 KEYNOTES: 1.CONCRETE FOOTING, SEE PLAN 2.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 2 VA R I E S , 2' - 0 " M A X 109 WOOD STUD WALL AT FOUNDATION NO SCALE 3" CLR 3" CL R 1 2 5 4 3 KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ ANCHOR BOLTS PER SHEARWALL SCHEDULE 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 6 VA R I E S , 2' - 0 " M A X 3 2' - 0 " PR E L I M I N A R Y NO T F O R CO N S T R U C T I O N 11 6 9 7 PRO F E S S I O N A L ENG I N E E R R E G I S TERE D S T ATE O F I D A H O M A R KEL L B A T E M A N MECHANICAL ENGINEERING ELECTRICAL ENGINEERING STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-494 04 / 1 3 / 2 0 2 3 205 WOOD TRUSS AT WOOD BEAM NO SCALE KEYNOTES: 1.ROOF SHEATHING, SEE PLAN 2.BOUNDARY NAILING, SEE PLAN 3.WOOD TRUSS W/ HANGER, SEE PLAN 4.WOOD BEAM, SEE PLAN 5.2x BLOCKING BETWEEN EA TRUSS 221 4 33 5 201 WOOD TRUSS AT WOOD STUD WALL NO SCALE KEYNOTES: 1.WOOD TRUSS, SEE PLAN 2.2x4x8'-0" LONG AT 48" O.C. W/ (2) 16d NAILS AT EACH TRUSS 3.2x BLOCKING W/ (2) 16d NAILS EACH END 4.WOOD STUD WALL, SEE PLAN 5.WALL SHEATHING AS OCCURS, SEE PLAN 6.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 7.EDGE NAILING, SEE SHEARWALL SCHEDULE 8.2x6 BLOCKING W/ (5) 16d NAILS AT EACH WALL STUD 9.2x6 BLOCKING AT 48" O.C., ALIGN W/ 2x6 BLOCK AT RIGHT. 10.BOUNDARY NAILING, SEE PLAN 11.ROOF SHEATHING, SEE PLAN 12.(4) 10d NAILS AT EACH BLOCK 13.CS16 (30" LONG) STRAP AT 48" O.C. W/ (22) 8d NAILS ATTACHING BLOCKS TOGETHER 14.BRICK VENEER PER ARCH, ATTACH PER GSN 1 2 3 4 5 89 11 10 12 6 7 7 7 1 2' - 0 " MA X 12 13 202 WOOD TRUSS AT WOOD STUD WALL NO SCALE KEYNOTES: 1.WOOD TRUSS W/ CLIP, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.WALL SHEATHING AS OCCURS, SEE PLAN 5.EDGE NAILING, SEE SHEARWALL SCHEDULE 6.ROOF SHEATHING, SEE PLAN 7.2x BLOCKING BETWEEN EACH TRUSS 8.BOUNDARY NAILING, SEE PLAN 9.2x6 PARAPET INTEGRAL W/ TRUSS BY TRUSS MANUFACTURE 10.BRICK VENEER PER ARCH, ATTACH PER GSN 11.2x BLOCKING AT ALL SHEATHING PANEL EDGES 1 2 3 4 9 6 8 2 5 7 5 KEYNOTES: 1.EXISTING STRUCTURE AS OCCURS 2.7 16" WALL SHEATHING 3.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 4.EDGE NAILING, SEE PLAN 5.A35 CLIP AT 24" O.C. 6.WOOD TRUSS, SEE PLAN 7.BOUNDARY NAILING, SEE PLAN 8.ROOF SHEATHING, SEE PLAN 9.2x4x8'-0" LONG AT 4'-0" O.C. W/ (2) 16d NAILS AT EACH TRUSS 10.ATTACH END TRUSS TO EXISTING BRICK VENEER W/ 14"Ø x 314" LONG TITEN TURBO SCREWS AT 48" O.C. 203 WOOD TRUSS AT WOOD STUD WALL NO SCALE 6 87 7 1 5 4 3 2 9 204 WOOD TRUSS AT WOOD STUD WALL NO SCALE KEYNOTES: 1.WOOD TRUSS W/ CLIP, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.WALL SHEATHING AS OCCURS, SEE PLAN 5.EDGE NAILING, SEE SHEARWALL SCHEDULE 6.ROOF SHEATHING, SEE PLAN 7.FULL-HEIGHT TRUSS BLOCKING BETWEEN EACH TRUSS W/ A35 CLIP 8.BOUNDARY NAILING, SEE PLAN 9.EXISTING STRUCTURE AS OCCURS 1 2 3 4 9 6 8 7 5 206 WOOD TRUSS AT WOOD STUD WALL NO SCALE KEYNOTES: 1.WOOD TRUSS W/ (2) 16d NAILS, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.2x BLOCKING BETWEEN EACH TRUSS 5.ROOF SHEATHING, SEE PLAN 6.BOUNDARY NAILING, SEE PLAN 1 2 3 6 5 4 1 207 WOOD TRUSS AT WOOD BEAM NO SCALE KEYNOTES: 1.ROOF SHEATHING, SEE PLAN 2.BOUNDARY NAILING, SEE PLAN 3.EXISTING STRUCTURE AS OCCURS 4.FULL-HEIGHT 2x BLOCK BETWEEN EACH TRUSS 5.WOOD BEAM, SEE PLAN 6.WOOD TRUSS W/ CLIP, SEE PLAN 1 56 2 3 4 10 14 5 10 208 WOOD TRUSS AT WOOD STUD WALL NO SCALE 2 13 9 3 3 5 4 KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.EDGE NAILING, SEE SHEARWALL SCHEDULE 4.2x8 BLOCKING BETWEEN EACH JOIST 5.WOOD TRUSS, SEE PLAN 6.2x6 BLOCK AT EACH STUD W/ (4) 8d NAILS 7.(4) 16d NAILS 8.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 9.WALL SHEATHING AS OCCURS, SEE PLAN 10.BOUNDARY NAILING, SEE PLAN 11.ROOF SHEATHING, SEE PLAN 12.CONT 2x BOTTOM PLATE W/ 16d NAILS AT 4" O.C. 13.2x6 WALL STUDS AT 16" O.C. 14.2x6 KICKER BRACE AT 32" O.C. W/ (5) 16d NAILS EACH END 15.IF KICKER BRACE EXCEEDS 6'-0" PROVIDE PERPENDICULAR STUD BRACE W/ (2) 16d NAILS AT EACH KICKER 16.2x BLOCK AT EACH KICKER W/ (4) 8d NAILS 17.BRICK VENEER PER ARCH, ATTACH PER GSN 18.2x BLOCKING AT ALL SHEATHING PANEL EDGES 6 11 3' - 6 " MA X 10 7 12 8 3 33 15 1 14 16 1 1 KEYNOTES: 1.EXISTING STRUCTURE AS OCCURS 2.WOOD TRUSS, SEE PLAN 3.2x4 x 8'-0" LONG AT 6'-0" O.C. W/ (2) 16d NAILS AT EACH TRUSS 4.ATTACH END TRUSS TO EXISTING BRICK VENEER W/ 14"Ø x 314" LONG TITEN TURBO SCREWS AT 48" O.C. 5.BOUNDARY NAILING, SEE PLAN 6.ROOF SHEATHING, SEE PLAN 209 WOOD TRUSS AT WOOD STUD WALL NO SCALE 2 65 5 1 3 4 17 210 WOOD TRUSS AT MASONRY WALL NO SCALE KEYNOTES: 1.WOOD TRUSS, SEE PLAN 2.CONT 2x PT PLATE W/ 5 8"Ø ANCHOR BOLT AT 24" O.C. W/ 5" MIN EMBEDMENT 3.MASONRY WALL, SEE PLAN 4.BOUNDARY NAILING, SEE PLAN 5.ROOF SHEATHING, SEE PLAN 6.WOOD TRUSS W/ HGA10 CLIP AT 36" O.C. 7.2x4 x 6'-0" LONG AT 48" O.C. W/ (2) 16d NAILS AT EACH TRUSS 8.2x TRUSS BLOCK AT 48" O.C. 9.SIMPSON HTC4 CLIP AT EACH TRUSS BLOCK 1 2 6 1 5 4 3 7 KEYNOTES: 1.WOOD TRUSS, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.WALL SHEATHING AS OCCURS, SEE PLAN 5.EDGE NAILING, SEE SHEARWALL SCHEDULE 6.WOOD TRUSS ALIGNED W/ SHEARWALL W/ CLIPS PER PLAN 7.BOUNDARY NAILING, SEE PLAN 8.ROOF SHEATHING, SEE PLAN 9.2x4 x 8'-0" LONG AT 6'-0" O.C. W/ (2) 16d NAILS AT EACH TRUSS 2 3 4 6 1 8 7 5 211 WOOD TRUSS AT WOOD STUD WALL NO SCALE 9 8 9 55 33 11 18 NOTE: A.PLACE A MOISTURE BARRIER BETWEEN ANY NON-PRESSURE TREATED LUMBER THAT IS IN CONTACT W/ (E) BRICK VENEER NOTE: A.PLACE A MOISTURE BARRIER BETWEEN ANY NON-PRESSURE TREATED LUMBER THAT IS IN CONTACT W/ (E) BRICK VENEER NOTE: A.PLACE A MOISTURE BARRIER BETWEEN ANY NON-PRESSURE TREATED LUMBER THAT IS IN CONTACT W/ (E) BRICK VENEER NOTE: A.PLACE A MOISTURE BARRIER BETWEEN ANY NON-PRESSURE TREATED LUMBER THAT IS IN CONTACT W/ (E) BRICK VENEER 2 212 WOOD TRUSS AT WOOD STUD WALL NO SCALE KEYNOTES: 1.WOOD TRUSS W/ CLIP, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.WALL SHEATHING AS OCCURS, SEE PLAN 5.EDGE NAILING, SEE SHEARWALL SCHEDULE 6.ROOF SHEATHING, SEE PLAN 7.FULL-HEIGHT TRUSS BLOCKING BETWEEN EACH TRUSS W/ A35 CLIP 8.BOUNDARY NAILING, SEE PLAN 9.EXISTING STRUCTURE AS OCCURS 10.GYP BOARD PER ARCH 1 2 3 4 9 6 8 7 5 NOTE: A.PLACE A MOISTURE BARRIER BETWEEN ANY NON-PRESSURE TREATED LUMBER THAT IS IN CONTACT W/ (E) BRICK VENEER 10 PR E L I M I N A R Y NO T F O R CO N S T R U C T I O N 11 6 9 7 PRO F E S S I O N A L ENG I N E E R R E G I S TERE D S T ATE O F I D A H O M A R KEL L B A T E M A N MECHANICAL ENGINEERING ELECTRICAL ENGINEERING STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-494 04 / 1 3 / 2 0 2 3 F: \ 2 2 \ 2 2 2 0 3 M a d i s o n J H S A d d i t i o n \ 2 2 2 0 3 P 1 . 0 1 . d w g A p r 1 9 , 2 0 2 3 - 3 : 4 7 p m Engineered Systems Associates Apr 19, 2023 PLAN NOTES: SEE SITE PLAN FOR CONTINUATION. REMOVE AND DISPOSE OF EXISTING OVERFLOW ROOF DRAIN LINE AND WALL FLANGE AS INDICATED ON PLANS. ROUTE NEW 3" ROOF OVERFLOW DRAIN AS INDICATED ON PLANS TO NEW WALL FLANGE. FIELD VERIFY EXISTING CONDITIONS. RE-USE EXISTING HEAT TRACE AS MUCH AS POSSIBLE. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. SEE FIRE NOTE BELOW. EXISTING ROOF DRAIN AND OVERFLOW DRAIN ABOVE TO REMAIN. PROTECT DURING CONSTRUCTION. SEE ROOF DRAIN PLAN ON THIS SHEET FOR CONTINUATION. ROUTE ROOF DRAIN LINES AS HIGH AS POSSIBLE IN ROOF TRUSS SPACE. COORDINATE WITH OTHER TRADES FOR BEST POSSIBLE ROUTES. ROOF DRAIN LINES TO BE INSULATED. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. SEE PIPE SUPPORT AND ROOF DRAIN DETAILS ON SHEET P2.01. 1 Nor t hSTORM, WASTE & VENT PLUMBING FLOOR PLAN - CLASSROOM SCALE: 1/8" = 1'-0" KEY MAP SCALE: NO SCALE EXISTING 6" SANITARY LOCATION CLASSROOM LOCATION 4" COTG 1 FD-1 L-1 S-1 Nor t h INV. ELEV AT 1/8" SLOPE: 97' 8" BALL TYPE ISOLATION VALVE PIPE RISE PIPE DROP SYMBOL CO WCO COTG VTR V VENT VENT THRU ROOF CLEANOUT WALL CLEANOUT CLEANOUT TO GRADE DESCRIPTION PLUMBING LEGEND SOIL OR WASTE PIPING VENT LINE PIPING DOMESTIC HOT WATER PIPING HARD COLD WATER PIPING DOMESTIC HW RECIRC. PIPING CD CONDENSATE DRAIN LINE G NATURAL GAS PIPING DOMESTIC 140°F HW PIPING140°F A-THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONNECTIONS ON THE JOB SITE. ALL WORK SHALL BE EXECUTED FROM MEASUREMENTS TAKEN AT THE SITE. GENERAL NOTES: G NATURAL GAS REGULATOR GW GREASE WASTE A- FIRE NOTES: B-THE CONTRACTOR SHALL INSTALL INTUMESCENT FIRE BLOCKS ON PLASTIC PENETRATIONS THRU FIRE RATED WALLS, FLOORS, OR CEILINGS. REFER TO SPECIFICATIONS FOR APPROVED MANUFACTURES. A-THE CONTRACTOR SHALL FIRE CAULK ALL DUCT OR PIPE PENETRATIONS THRU FIRE RATED WALLS, FLOORS, OR CEILINGS. L-1 L-1 L-1 4" VTR WCO WC O WH-1 EW-1 JS-1 S- 1 S-1 S-1 S-1 S-1 WC-1WC-1 WC-2 WC-2U-1 U-2 FD-1FD-1 L-1 L-1 WC-1 WC-1 FD-1 FD-1 RP-1 RDO RDO RDO RDO 33 3" WF-1 2 3" 33 2 2 3 WCO (HIGH) 4"4"4"2" 2" 2" 2" 2" 4" 4" 2"2" 2" 2" 2"3" 2" 3" 2" 4" 4" 4" 2"3" 3" 2" 2" 4" 2"2"3"3970 SQ. FT. ROOF AREA. 3970 x 0.0104 x 1.5 = 61.9 GPM 62 GPM = 4" PIPE @ 1/8" SLOPE RD L RDL RDL RDL RDL RDL RDL RDL RDL RDL RDL RDL RDL RDL RD L RD O 3970 SQ. FT. ROOF AREA. 3970 x 0.0104 x 1.5 = 61.9 GPM 62 GPM = 4" PIPE @ 1/8" SLOPE 3970 SQ. FT. ROOF AREA. 3970 x 0.0104 x 1.5 = 61.9 GPM 62 GPM = 4" PIPE @ 1/8" SLOPE 4 4 Nor t hROOF DRAIN PLAN SCALE: 1/8" = 1'-0" RD-1 RD-1 (ABOVE) RD-1 (ABOVE) 1 6" COTG 4" (HIGH)4" (HIGH) 4" (HIGH) 4" (HIGH)4" (HIGH) (ABOVE) 5 5 5 5 5 5 4" (HIGH) 5 6" (HIGH) 5 4" (HIGH) 5 RDO RDO RDO RDO RDO RDO RDO RDO RDO RDO RDO RDO RDO RD O RD O 5 RD O 5 2" ROOF ACCESS DF-1 2" 4" 6" RDL DN 6" (HIGH) INV. ELEV 97' 8" 6" CONNECT TO EXISTING CONNECT TO EXISTING 3" F: \ 2 2 \ 2 2 2 0 3 M a d i s o n J H S A d d i t i o n \ 2 2 2 0 3 P 1 . 0 2 . d w g A p r 1 9 , 2 0 2 3 - 3 : 4 7 p m Engineered Systems Associates Apr 19, 2023 PLAN NOTES: Nor t hWATER & GAS PLUMBING FLOOR PLAN - CLASSROOM SCALE: 1/8" = 1'-0" KEY MAP SCALE: NO SCALE CLASSROOM LOCATION EXISTING 4" DOMESTIC WATER RISER LOCATION Nor t h REMOVE THE EXISTING 1-1/4” AND 3” GAS PIPES AND PRESSURE REGULATOR ON THE EXISTING EXTERIOR WALL. RELOCATED REGULATOR TO 1-1/4” GAS PIPE ON THE ROOF. PROVIDE 3” GAS PIPE FROM REGULATOR THROUGH NEW ROOF AND CONNECT TO EXISTING 3”. REMOVE EXISTING GAS PIPE UNDERGROUND BELOW THE ADDITION. IF THE LINE IS ACTIVE, CAP BELOW GROUND 3 FEET BEYOND BUILDING FOUNDATION. CONNECT 1” GAS PIPE TO EXISTING 3” ON ROOF (REFER TO KEY MAP). CONFIRM EXISTING CONDITIONS PRIOR TO BID. PROVIDE SHUT-OFF VALVE TO 1” AT CONNECTION. INSTALL GAS PIPING ABOVE ROOF ON PYRAMID TYPE PIPE SUPPORTS AT EVERY 6’-0” (REFER TO DETAIL SHEETS). COORDINATE SHUTDOWN WITH OWNER. INSTALL TRAP PRIMER MANIFOLD IN WALL WITH ACCESS DOOR (REFER TO DETAIL SHEETS). WATER HAMMER ARRESTOR (REFER TO SPECIFICATIONS). ADDITION SHALL HAVE FIRE SPRINKLER COVERAGE TO MEET NFPA 13 CODE REQUIREMENTS. FIRE SPRINKLER DESIGN SHALL BE BASED ON HYDRAULIC CALCULATIONS AND RECENT HYDRANT FLOW TESTS. CONNECT TO EXISTING FIRE SPRINKLER SYSTEM AT NEAREST LOCATION IF ALLOWED BY CODE AS NOT EXCEED THE TOTAL ALLOWABLE AREA. UNCONDITIONED SPACE INCLUDING THE VESTIBULE SHALL HAVE DRY HEADS. REFER TO DETAIL SHEETS FOR MORE INFORMATION. CONNECT DOMESTIC WATER TO EXISTING 4” IN EXISTING MECHANICAL ROOM (REFER TO KEY MAP). REFER TO DETAIL SHEETS FOR PIPE SUPPORTS. CONNECT GAS PIPING TO ROOFTOP UNITS WITH SHUT-OFF VALVE, DRIP LEG AND FLEXIBLE HOSE (REFER TO DETAIL SHEET). REFER TO SHEET P1.03 FOR CONTINUATION. 1 2 3 4 5 6 2" 6 6 5 55555 5 5 5 5 5 5 5 55 5 5 5 55 HB-1 WC-1WC-1 L-1 WC-2 WC-2 L-1 WC-1 WC-1 G G G G G G G G G G G G G G G L-1 L-1 S-1S-1 S-1 3 U-2 RT 1 RT 2 RT 3 RT 4 RT 5 RT 7 RT 8 RT 9 RT 6 FD-1FD-1 FD-1 FD-1 WH-1 RP-1 FD-1 S-1 EW-1 JS-1 1 5 EXISTING FIRE RISER LOCATION TP-1 7 777777777 4 1" 1/2" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 1" 2" 2" 2" 3/4" 3/4" 3/4" 1" 1" 1-1/4" 3/4" 1-1/2" 1- 1 / 4 " 1-1/2"U-1 3/4" GAS LOAD CALC. 1"MAIN GAS PIPE SIZE 10 PSIDISCHARGE PRESSURE 500'DEVELOPED LENGTH 1,585,000 BTUTOTAL DESIGN LOAD 320,000 x 1 = 320,000 BTU/HRT-10 120,000 x 9 = 1,080,000 BTU/HRT-1 THRU RT-9 1,400,000 BTU/HTOTAL BTU LOAD G G G G G G G EXISTING GAS METER LOCATION 2 1" 10 PSI TO 0.5" W.C. REGULATOR 1" 2" 2"1-1/2"1-1/2"1-1/2"1-1/2"1-1/4"1" 3/4" 2 2 8 8 ROOF ACCESS (ABOVE)(ABOVE)(ABOVE)(ABOVE)(ABOVE)(ABOVE)(ABOVE)(ABOVE)(ABOVE) 2 2 2 L-1 L-1 S-1 S-1 SHUT OFF VALVE EXISTING 3" IN CEILING SPACE EXISTING 1-1/4" EXISTING 1-1/4" DN EXISTING 3" UP ON ROOF G 1"1"1"1"1" 1" 3/4" EW-2 EW-2 EW-2 F: \ 2 2 \ 2 2 2 0 3 M a d i s o n J H S A d d i t i o n \ 2 2 2 0 3 P 1 . 0 3 . d w g A p r 1 9 , 2 0 2 3 - 3 : 4 8 p m Engineered Systems Associates Apr 19, 2023 PLAN NOTES: Nor t hPLUMBING FLOOR PLAN - COMMONS SCALE: 1/8" = 1'-0" KEY MAP SCALE: NO SCALE Nor t h CONNECT GAS PIPING TO ROOFTOP UNIT WITH SHUT-OFF VALVE, PRESSURE REGULATOR, DRIP LEG AND FLEXIBLE HOSE (REFER TO DETAIL ON SHEET 2.02). ADDITION SHALL HAVE FIRE SPRINKLER COVERAGE TO MEET NFPA 13 CODE REQUIREMENTS. FIRE SPRINKLER DESIGN SHALL BE BASED ON HYDRAULIC CALCULATIONS AND RECENT HYDRANT FLOW TESTS. CONNECT TO EXISTING FIRE SPRINKLER SYSTEM AT NEAREST LOCATION IF ALLOWED BY CODE AS NOT EXCEED THE TOTAL ALLOWABLE AREA. UNCONDITIONED SPACE INCLUDING THE VESTIBULE SHALL HAVE DRY HEADS. REFER TO DETAIL SHEETS FOR MORE INFORMATION. EXTEND GAS PIPE TO CLASSROOM ADDITOIN. SEE SHEET P1.02 FOR CONTINUATION. INSTALL GAS PIPING ABOVE ROOF ON PYRAMID TYPE PIPE SUPPORTS AT EVERY 6’-0” (REFER TO DETAIL SHEETS). PROVIDE OFFSETS FOR OBSTRUCTIONS INCLUDING PARAPETS. CONNECT DOMESTIC WATER TO EXISTING 4” IN EXISTING MECHANICAL ROOM. REFER TO DETAIL SHEETS ON SHEET P2.01 FOR PIPE SUPPORTS. EXTEND WATER PIPE TO CLASSROOM ADDITION. SEE SHEET P1.02 FOR CONTINUATION. ROUTE WATER LINE IN CEILING SPACE. COORDINATE WITH THE GENERAL CONTRACTOR AND OWNER FOR THE REQUIRED WORK. REPAIR ANY DAMAGED TILES. SEE PIPE SUPPORT DETAIL ON SHEET P2.01. RELOCATE EXISTING AUTO SPRINKLER FIRE DEPARTMENT CONNECTION. EXTEND TO EXISTING PIPE IN MECHANICAL ROOM. COORDINATE WITH THE GENERAL CONTRACTOR FOR THE REQUIRED PATCHING AFTER WORK IS COMPLETED. REMOVE THE EXISTING FIRE RISER, FIRE DEPARTMENT CONNECTION, DRAIN, AND ALL COMPONENTS INSIDE THE FIRE RISER CLOSET. REPLACE THE FIRE RISER WITH A 4” PIPE. REPAIR OPENINGS IN WALL. PROVIDE A REPLACEMENT FIRE RISER WET-PIPE ALARM VALVE ON 4” FIRE RISER IN MECHANICAL ROOM ABOVE THE 3” CONNECTION. PROVIDE VALVES WITH TAMPER SWITCHES, FIRE DEPARTMENT CONNECTION, DRAIN, FLOW SWITCH, AND ALL OTHER COMPONENTS AS REQUIRED BY NFPA 13. CONNECT TO THE EXISTING FIRE SPRINKLER AND ALARM SYSTEM. COORDINATE WITH THE GENERAL CONTRACTOR FOR THE REQUIRED PATCHING AFTER THE WORK IS COMPLETED. ROUTE ROOF DRAIN LINES AS HIGH AS POSSIBLE IN ROOF TRUSS SPACE. COORDINATE WITH OTHER TRADES FOR BEST POSSIBLE ROUTES. ROOF DRAIN LINES TO BE INSULATED. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. SEE PIPE SUPPORT AND ROOF DRAIN DETAILS ON SHEET P2.01. TIE 4" ROOF DRAIN LINE TO NEARBY EXISTING 6" DROP. FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION. 1 RT 10 1 EXISTING 6" SANITARY LOCATION COMMONS LOCATION FIRE FIRE 2 2 2 2 EXISTING ELECTRIC ALARM GONG 3 6 2" 4 4 5 5 6 PRV EXISTING FIRE DEPT CONNECTION & DRAIN 7 FIRE 7 8 EXISTING DRAIN 7 6 G G G G G 2"3 3 8 EXISTING 6" RDL DN RD L RDL RDL RDL RDL RDL RDL RDL 2160 SQ. FT. ROOF AREA. 2160 x 0.0104 x 1.5 = 33.7 GPM 34 GPM = 3" PIPE @ 1/8" SLOPE 2200 SQ. FT. ROOF AREA. 2200 x 0.0104 x 1.5 = 34.3 GPM 35 GPM = 3" PIPE @ 1/8" SLOPE RD L 4" (HIGH)3" (HIGH) 3" (HIGH)3" (HIGH) WF-2 (HIGH) RD O RD O RD O RD O RD-2RD-2 (ABOVE)(ABOVE) (ABOVE) 3" (HIGH)3" (HIGH) RDO RDO RDO RDO RDO 4" (HIGH) 9 9 9 9 9 9 9 9 G 2 RD L EXISTING 8" RDL 10 10 ---1/2"2"2"2" FLOOR DRAIN WITH PRIMER - ZURN Z-415B WITH 5"Ø NICKEL-BRONZE STRAINER AND 2" DEEP SEAL P-TRAP.PROVIDE WITH TRAP PRIMER CONNECTION. REFER TO DETAIL ON THIS SHEET FOR TYPICAL INSTALLATION AND 1/2" COLD WATER LINE CONNECTION. FD-1 COLD FIXTURE SCHEDULE DESCRIPTIONSYM.HOT WASTE VENT 1"---4"2"WC-1 ---4"2"WC-2 ADA FLUSH VALVE WATER CLOSET - KOHLER K-4368 "HIGHCLIFF" WITH ELONGATED BOWL, K-4670C WHITE OPEN FRONT SEAT, SLOAN REGAL BATTERY FLUSH VALVE AND CHINA BOLT CAPS. FLUSH VALVE WATER CLOSET - KOHLER K-4350 "WELCOMME" WITH ELONGATED BOWL, K-4670C WHITE OPEN FRONT SEAT, SLOAN REGAL BATTERY FLUSH VALVE AND CHINA BOLT CAPS. 1" ADA WALL MOUNTED URINAL - KOHLER K-4989-T "FRESHMAN" WITH WALL CARRIER & SLOAN REGAL 186 SFSM-0.5 BATTERY FLUSH VALVE. MOUNT AT ADA LEVEL. 2"---3/4"2"U-1 WALL MOUNTED URINAL - KOHLER K-4989-T "FRESHMAN" WITH WALL CARRIER & SLOAN REGAL 186 SFSM-0.5 BATTERY FLUSH VALVE. 2"---3/4"2"U-2 JS-1 2"2"1/2" BI-LEVEL ADA DRINKING FOUNTAIN - ELKAY MODEL LZSTL8WSLK WITH BOTTLE FILLER STATION & FILTER FRONT PUSH BAR OPERATORS, 1/2" STOP, 1-1/2" P-TRAP AND FLEX-GUARD SAFETY BUBBLER VALVE. ---DF-1 1-1/2"1/2"1-1/2" L-1 1-1/2"1-1/2"1/2"1/2"ADA WALL HUNG LAVATORY - KOHLER K-2031-0 "GREENWICH" WITH WALL CARRIER, MOEN L4601 LEVER FAUCET, K-7715 OPEN GRID STRAINER WITH OFFSET WASTE LINE, 1/2" STOPS AND 1-1/4" P-TRAP. PROVIDE AND INSTALL INSULATING JACKET ON HW AND WASTE PIPING. 1-1/2"1-1/2"1/2"1/2"S-1 F: \ 2 2 \ 2 2 2 0 3 M a d i s o n J H S A d d i t i o n \ 2 2 2 0 3 P 2 . 0 1 . d w g A p r 1 9 , 2 0 2 3 - 3 : 4 9 p m Engineered Systems Associates Apr 19, 2023 CONCRETE FILL SLAB STRUCTURAL FLOOR DRAIN OUTLET TO P-TRAP CEMENT BED FLOORING IF APPLICABLE 1/2" PEX M POWER BOX WITH 24 HOUR TIME CLOCK 120V - 1Ø POWER BALL TYPE SHUT-OFF VALVE TYPICAL UNION SOLENOID VALVE CAP ALL UNUSED PORTS RECESS MOUNTED TRAP PRIMER MANIFOLD BOX COMPLETE WITH COVER. MOUNT WHERE SHOWN ON PLANS. VACUUM BREAKER 3/4" COLD WATER LINE 1/2" 'PEX' PIPING TO ADDITIONAL FLOOR DRAIN AS REQUIRED. 3/4" CW LINE OVER RIDE SWITCH NO SCALE TRAP PRIMER DETAIL WATERPROOF MEMBRANE WHERE REQUIRED SERVICE SINK INSTALLATION DETAIL NO SCALE 2" VENT WALL 2" DRAIN LINE P-TRAP FLOOR WALL CLEAN OUT WHERE CALLED OUT SEAL ALL AROUND WITH SILICONE CAULKING GROUT SINK IN PLACE AND SET LEVEL FLOOR MOUNTED SERVICE SINK CLEAN OUT DETAILS NO SCALE CLEANOUT TO GRADE (COTG) WASTE LINE FINISH GRADE 1'-0" WALL CLEANOUT (WCO) 1/8 BEND FLOOR LINE WALL BRASS CLEANOUT PLUG WITH COUNTER SUNK HEAD 16" SQUARE CONC PAD TROWEL SMOOTH 1/8 BEND IF CLEANOUT OCCURS AT END OF LINE. WASTE LINE. LENGTH TO SUIT. CHROME WALL COVER AND SCREW MAY EXTEND AS A WASTE OR VENT PLUGGED TEE WITH CLEANOUT BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. 1/8 BEND G GAS COCK DIRT LEG TYPICAL UNION R PIPE FULL SIZE TO FLOOR G GAS PIPING EARTHQUAKE RESTRAINT EARTHQUAKE RESTRAINT HOT WATER LINE GAS FIRED WATER HEATER PIPING DIAGRAM NO SCALE DRAIN VALVE W/ THREADED HOSE CONNECTION GAS FIRED SEALED COMBUSTION WATER HEATER T & P RELIEF VALVE SIZED TO MATCH WATER HEATER POWER VENT FAN TYP. BALL VALVE 3/4" TYP. CHECK VALVE AMTROL ST-5 EXPANSION ANCHORED TO WALL RECIRCULATING PUMP HOT WATER RECIRC OPERATING THERMOSTAT AQUASTAT COLD WATER LINE EMERGENCY EYEWASH DETAIL NO SCALE EMERGENCY EYEWASH STATION - HAWS 7260BT WITH PUSH-OPEN BALL VALVE, EYEWASH BOWL ,1/2" SUPPLY LINE, WATTS SERIES LFMMV MIXING VALVE, AND 1-1/2" WASTE LINE WITH P-TRAP. REFER TO DETAIL ON THIS SHEET. EW-1 1-1/2"1-1/2"1/2"1/2" HB-1 ------3/4"---EXTERIOR HOSE BIBB - ZURN Z-1310 "ECOLOTROL" WITH REMOVABLE KEY, VACUUM BREAKER AND AUTOMATIC DRAIN. LENGTH TO SUIT WALL THICKNESS. WALL FLANGE - JAY R SMITH MODEL 1770 SIZE 6" WITH ROUGH BRONZE FINISH AND 6" DRAIN LINE CONNECTION. ---WF-1 6"------ FLOOR MOUNTED SERVICE SINK - KOHLER K-6710 "WHITBY" W/ K-8940 WIRE RIM GUARD, K-8928 FAUCET ASSEMBLY AND K-9142 STRAINER WITH DEEP SEAL P-TRAP, HOSE AND HOSE CLAMP. 1/2" EXTERIOR HOSE BIBB DETAIL NO SCALE FLOOR VALVE HOUSING REMOVABLE KEY GRADE GROUT AROUND BIBB IN WALL EXTERIOR WALL 3/4" HOSE CONNECTION WITH ANTI-SIPHON VACUUM BREAKER ADJUSTABLE CLAMP SECURE PIPE TO WALL STUD AT RISE WITH PIPE CLAMP 3/4" COLD WATER LINE DOWN IN WALL 12" MIN. 24" MAX. EYE WASH FOUNTAIN PUSH HANDLE OPERATOR FLOOR 33" MIN. 45" MAX. 1-1/2" DRAIN 1/2" COLD WATERMOUNTING BRACKET FASTENED TO WALL MOUNTING BRACKET FASTENED TO WALL FRONT VIEW SIDE VIEW ADJACENT SERVICE SINK WATTS SERIES LFMMV MIXING VALVE IN WALL WITH ACCESS BOX. SINGLE COMPARTMENT SINK - ELKAY LR-1719 STAINLESS STEEL SINK WITH LK-99 STRAINER, 3-HOLE DRILLING, MOEN 8248 TWO LEVER PADDLE FAUCET, 1/2" STOPS AND 1-1/2" P-TRAP. PIPE SUPPORT DETAIL CEILING JOIST ROOF OR PIPING TO SUPPORTS SECURE CLAMP ASSEMBLYTHRU RUN INSULATION OF CLAMP OR EQUAL WITH "UNISTRUT" PIPING. SEE TYPICAL PIPING NO SCALE HANGER RODS OR EQUAL (TYPICAL) "UNISTRUT" CHANNEL 1-5/8" P-1001 INSULATION ON ALL PIPING SUPPORTS OF JOISTS. NO PIPING SUPPORTS ARE TO BE PRIOR TO FIREPROOFING FIREPROOFING HAS BEEN DONE. ARE TO BE INSTALLED ATTACHED AFTER NOTE: 1" CHANNEL (UNISTRUT OR FEE & MASON) WELD TO JOISTS SPECIFICATIONS TP-1 TRAP PRIMER - ZURN Z-1022XL IN-LINE PRIMER. MOUNT RECESSED IN WALL BELOW SINK WHERE SHOWN ON PLANS. RUN 1/2" COLD WATER LINE BELOW FLOOR TO CORRESPONDING FLOOR DRAIN. REFER TO DETAIL ON THIS SHEET FOR TYPICAL INSTALLATION. ------1/2"--- ROOF DRAIN DETAIL NO SCALE COMBINATION ROOF AND OVERFLOW DRAIN SYSTEM - ZURN LIGHT COMMERCIAL RD1230 SYSTEM WITH 4" ROOF DRAIN AND OVERFLOW DRAIN LINE CONNECTIONS. ---4"------RD-1 ROOF DECK CAST IRON BODY UNDERDECK CLAMP CAST IRON DOME OVERFLOW DRAINMAIN ROOF DRAIN ROOF INSULATION 2" HIGH WATER DAMCAST IRON CLAMP DEVICE WITH INTEGRAL GRAVEL GUARD 36" SQUARE FLASHING UNDER SINGLE PLY ROOF MEMBRANE CAST IRON DOME OVERFLOW DRAINROOF DRAIN RP-1 HOT WATER RECIRC. PUMP - B&G SERIES LR-20BF 'LITTLE RED' WITH 4 GPM FLOW AT 8' HEAD AND 3/4" LINE CONNECTIONS. MOUNT NEAR WATER HEATER. REFER TO DETAIL FOR TYPICAL PIPE CONNECTION. (120V/1P, 1.1 AMPS) ---3/4"------ COUNTER AS DETAILED BY ARCHITECT. PUSH HANDLE OPERATOR FLOOR 1/2" COLD WATER 1/2" SWIVELSINK AND FAUCET AS SPECIFIED ON PLANS NOTE: ANSI STANDARD SPECIFIED EYEWASH NOZZLE HEIGHTS TO BE 33" MIN. TO 45" MAX. ABOVE FLOOR. CENTERLINE OF EYEWASH HEADS MUST BE 6"MIN. AWAY FROM WALL. EW-1 EMERGENCY EYE WASH NO SCALE 1-1/2"1-1/2"1/2"---EW-2 EMERGENCY EYEWASH - HAWS MODEL 7260B WALL MOUNTED EYE WASH WITH 11"Ø PLASTIC RECEPTOR, PROVIDE 1/2" WASTE LINE WITH P-TRAP AND VENT. REFER TO DETAIL ON THIS SHEET FOR TYPICAL INSTALLATION. M MIXING VALVE FOR TEMPERED WATER 3/4"3/4"------WH-1 ELECTRIC WATER HEATER - A.O. SMITH MODEL ECL-50 WITH 50 GALLON CAPACITY, (2) 4.5 KW NON- SIMULTANEOUS ELEMENTS (208/60/1), 3/4" SUPPLIES AND T&P RELIEF VALVE, THERMAL EXPANSION TANK, HEAT TRAP NIPPLES. WALL FLANGE - JAY R SMITH MODEL 1770 SIZE 4" WITH ROUGH BRONZE FINISH AND 4" DRAIN LINE CONNECTION. ---WF-2 4"------ COMBINATION ROOF AND OVERFLOW DRAIN SYSTEM - ZURN LIGHT COMMERCIAL RD1230 SYSTEM WITH 3" ROOF DRAIN AND OVERFLOW DRAIN LINE CONNECTIONS. ---3"------RD-2 F: \ 2 2 \ 2 2 2 0 3 M a d i s o n J H S A d d i t i o n \ 2 2 2 0 3 P 2 . 0 2 . d w g A p r 1 9 , 2 0 2 3 - 3 : 4 9 p m Engineered Systems Associates Apr 19, 2023 ROOF TOP UNIT GAS CONNECTION DETAIL NO SCALE 4" MIN. 4" O R 6 " 10-3/8" POLYETHYLENE BASE GALVANIZED STRUT CLIP POLYETHYLENE BASE GALVANIZED STRUT CLIP 24" MIN. R R 8" 5- 5 / 8 " PIPING ON ROOF SUPPORT DETAILS NO SCALE POLYETHYLENE BASE GALVANIZED STRUT CLIP PIPE CLAMPTYP. PIPE CLAMP TYP. PIPE CLAMP TYP. PIPE GALVANIZED STRUT CLIP SPRINKLER HEAD COORDINATION DETAILS DRY PENDANT HEAD DETAIL SPRINKLER PIPING 3" MIN. CLEAR HVAC GRILLE OR REGISTER CEILING SPRINKLER HEAD 6"' MIN. SPRINKLER PIPING 3" MIN. CLEAR CEILING LIGHT FIXTURE PENDANT SPRINKLER HEAD WHITE ESCHUTCHEON WITH WHITE EXTENSION PENDANT SPRINKLER HEAD WHITE ESCHUTCHEON WITH WHITE EXTENSION RECESSED WHITE ESCUTCHEON AT SUSPENDED CEILINGS SPRINKLER PIPING UPRIGHT SPRINKLER WHERE STRUCTURE IS EXPOSED OR IN ABOVE CEILING INSTALLATIONS. WHITE CANOPY ESCUTCHEON CONCEALED HEADS WITH CAP SPRINKLER PIPING ROOF SYSTEM "X " CEILING DISTANCE 'X' BETWEEN COLD BARRIER AND THE SEAL FOR THE DRY PENDENT HEAD SHALL NOT BE LESS THAN 12" LOCATION OF DRY SPRINKLER PLUG AND SEAL TO BE IN WARM SPACE COLD BARRIER FREEZING APPLICATIONS (TEMPERATURES LESS THAN 32°F) DRY PENDENT BARREL COUPLING PIPE WET PIPE SYSTEM IN WARM SPACE CEILING LOCATION OF DRY SPRINKLER PLUG AND SEAL TO BE IN WARM SPACE COUPLING WET PIPE SYSTEM IN WARM SPACE COLD BARRIER DR Y P E N D E N T B A R R E L PROVIDE AND INSTALL DRY PENDENT HEADS IN ALL PLACES WITH FREEZING POTENTIAL AND WHERE OUTSIDE BUILDING INSULATION ENVELOPE. STEEL ROOF DECK 3/8" ALL-THREAD ROD BRANCHLINE PIPE STEEL STRUCTURE RETAINING STRAP STEEL STRUCTURE BEAM CLAMP WITH SET SCREW STEEL ROOF DECK BEAM CLAMP WITH SET SCREW RETAINING STRAP 3/8" ALL-THREAD ROD BRANCHLINE PIPE PIPE HANGER DETAILS NO SCALE NO SCALE NO SCALE 6" V E R T I C A L EQUIPMENT ROOF GROUND JOINT UNION CAPPED PRESSURE TEE GAS PRESSURE REGULATOR 10# TO 1/2# (IF APPLICABLE) PROVIDE ESCHUCEON PLATE AROUND PIPING FLEXIBLE GAS CONNECTOR. 18" MAX. DRIP LEG SAME SIZE AS PIPE MANUAL MAIN SHUT-OFF VALVE 'PYRAMID' TYPE SUPPORTS 6" V E R T I C A L GAS LINE CONNECTION DETAIL NO SCALE 3/4" DROP FROM MAIN. SEE PLAN FOR SIZE MANUAL MAIN SHUT-OFF VALVEGROUND JOINT UNION EQUIPMENT CASING FLEXIBLE GAS CONNECTOR. 18" MAX. DRIP LEG SAME SIZE AS DROP F: \ 2 2 \ 2 2 2 0 3 M a d i s o n J H S A d d i t i o n \ 2 2 2 0 3 M 1 . 0 1 . d w g A p r 1 9 , 2 0 2 3 - 3 : 4 5 p m Engineered Systems Associates Apr 19, 2023 PLAN NOTES: A-THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONNECTIONS ON THE JOB SITE. ALL WORK SHALL BE EXECUTED FROM MEASUREMENTS TAKEN AT THE SITE. ALL DUCTWORK AND PIPING WHICH PASSES THRU FIRE RATED WALLS TO BE FIRE STOPPED WITH APPROVED FOAM OR SEALANT. REFER TO SPECIFICATIONS FOR APPROVED MANUFACTURES. B- GENERAL NOTES: INSTALL ROOFTOP EQUIPMENT AS SCHEDULED ON SHEET M2.01. MOUNT UNIT ON ROOF CURB AND DROP DUCTWORK DOWN THRU ROOF. SEE DETAILS ON SHEET M2.01. COORDINATE WITH STRUCTURAL FOR EXACT ROOF TOP UNIT LOCATION. KEEP UNITS MIN 6' AWAY FROM OTHER ROOF TOP UNITS. EXISTING OUTSIDE AIR LOUVER TO BE REMOVED AND DISPOSED. EXTEND AND MODIFY DUCTWORK AS REQUIRED FOR NEW PENTHOUSE. FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION. SEE SHEET M2.01 FOR PENTHOUSE INSTALL DETAILS. INSTALL NEW DUCTED PLENUM 22" WIDE, 50" HIGH, & 26" DEEP BEHIND RETURN AIR GRILLE. DROP 20x12" RETURN AIR DUCT AND CONNECT TO PLENUM. 1 ELECTRONIC THERMOSTAT EQUIPMENT SYMBOLFC 1 T INSULATED FLEXIBLE DUCT CEILING DIFFUSER ROUND BRANCH DUCT WITH HAND DAMPER HAND DAMPER HD MECHANICAL LEGEND DESCRIPTIONSYMBOL EXHAUST GRILLE RETURN AIR OR SMOKE DETECTOR Nor t hMECHANICAL FLOOR PLAN - CLASSROOMS SCALE: 1/8" = 1'-0" KEY MAP SCALE: NO SCALE CLASSROOM LOCATION Nor t h T T T T T D-1 300 D-1 300 D-1 300 D-1 300 12 x 1 2 " S A HDHD HDHD 10"Ø SA10"Ø SA 10"Ø SA D-1 D-1D-1 D-1 300 300 300300 10" Ø SA HD HD HD HD 20 x 1 2 " S A 10"Ø SA 10"Ø SA 10"Ø SA D-1 D-1D-1 D-1 300 300 300300 10" Ø SA HD HD HD HD 20 x 1 2 " S A 10"Ø SA 10"Ø SA 10"Ø SA D-1 D-1 D-1 D-1 300300 300 300 10" Ø SA HDHD HDHD 20 x 1 2 " S A 12 x 1 2 " S A 10"Ø SA 10"Ø SA 10"Ø SA D-1 D-1 D-1 D-1 300300 300 300 10" Ø SA HDHD HDHD 20 x 1 2 " S A 10"Ø SA 10"Ø SA 10"Ø SA HD HD HD HD 10"Ø SA 10"Ø SA 20 x 1 2 " S A HD HD HD HD 10"Ø SA 10"Ø SA 10"Ø SA10"Ø SA D-1 D-1D-1 D-1 300 300 300300 10" Ø SA HD HD HD HD 20 x 1 2 " S A 10"Ø SA 10"Ø SA 10"Ø SA D-1 300 D-1 300 D-1 300 D-1 300 D-1 300 D-1 300 D-1 300 D-1 300 20 x 1 2 " R A 20 x 1 2 " R A 20x12" RA 20 x 1 2 " R A 20 x 1 2 " S A 20 x 1 2 " S A 12 x 1 2 " S A 12 x 1 2 " S A T T 20 x 1 2 " R A T EG-1 240 D-2 190 EF 1 EG-2 70 EG-2 70 20x12" RA D-2 190 8"Ø EA UP RC-1 EF 2 EG-1 240 8"Ø SA 8"Ø SA HD D-1 350 RT 1 RT 2 RT 3 RT 4 RT 5 RT 6 RT 7 RT 8 RT 9 10"Ø EA10"Ø EA 6" Ø E A 6" Ø E A 8x8" EA 8"Ø EA UP RC-1 EF 2 8"Ø EA UP RC-1 EF 2 8"Ø EA UP RC-1 EF 2 20 x 1 2 " S A D-1 270 20x12" RA 10"Ø SA 20x12" RA 10"Ø SA T 20x12" RA 10"Ø SA 10"Ø SA 10"Ø SA 1 1 1 1 1 1 1 1 1 12x12" EA D-1 200 8"Ø SA 20x12"DN20x12"DN 20x12"DN 20x12"DN 20x12"DN RG-2 RG-1RG-1RG-1 RG-1 RG-1 RG-1 RG-1 RG-1 20x12"DN 20x12"DN20x12"DN HD HD 10"Ø SA 2 242x42" OA UP PH-1 PH-2 2 2 3 FIRE DAMPERFD EXIST 40x26" OA ROOF ACCESS RT-1 RT-3 RT-5 RT-7 2 PH-2 20x20" OA UP 20x20" OA UP 20x20" OA 20x20" OA 12 x 1 2 " S A 12 x 1 2 " S A 12 x 1 2 " S A 12 x 1 2 " S A 3 RT-2 RT-4 RT-6 RT-9 3 3 3 3 333 2 F: \ 2 2 \ 2 2 2 0 3 M a d i s o n J H S A d d i t i o n \ 2 2 2 0 3 M 1 . 0 2 . d w g A p r 1 9 , 2 0 2 3 - 3 : 4 6 p m Engineered Systems Associates Apr 19, 2023 PLAN NOTES: Nor t hMECHANICAL FLOOR PLAN - COMMONS SCALE: 1/8" = 1'-0" KEY MAP SCALE: NO SCALE Nor t h INSTALL ROOF TOP EQUIPMENT AS SCHEDULED ON SHEET M2.01. MOUNT ON ROOF CURB AND DROP DUCTWORK DOWN THRU ROOF. SEE DETAILS ON SHEET M2.01. COORDINATE WITH STRUCTURAL FOR EXACT ROOF TOP UNIT LOCATION. INSTALL TOP OF DUCT 6" BELOW BOTTOM OF ROOF TRUSS. ROUTE RETURN DUCTWORK IN ROOF TRUSS SPACE. APPROXIMATE LOCATIONS OF ROOF TRUSS. SEE STRUCTURAL PLANS FOR EXACT SIZE & LOCATIONS. EXISTING 6" FLUE & CORRESPONDING WALL CAP TO BE REMOVED AND RE-LOCATED. EXTEND TYPE-B FLUE AS REQUIRED. CORE DRILL OUTSIDE WALL FOR NEW LOCATION. MINIMUM 96" FROM FLOOR TO BOTTOM OF OPENING. COORDINATE WITH THE GENERAL CONTRACTOR FOR THE REQUIRED PATCHING AFTER THE WORK IS COMPLETE. EXISTING 7" COMBUSTION VENT TO BE REMOVED AND RE-LOCATED. CORE DRILL OUTSIDE WALL FOR NEW LOCATION. MINIMUM 96" FROM FLOOR TO BOTTOM OF OPENING. COORDINATE WITH THE GENERAL CONTRACTOR FOR THE REQUIRED PATCHING AFTER THE WORK IS COMPLETE. EXISTING PVC VENTS TO BE REMOVED. COORDINATE WITH THE GENERAL CONTRACTOR FOR THE REQUIRED PATCHING. REMOVE EXISTING SOFFIT GRILLE AND DISPOSED OF. RUN NEW DUCTWORK UP TO NEW PENTHOUSE ON EXISTING ROOF. COORDINATE WITH THE GENERAL CONTRACTOR FOR THE REQUIRED PATCHING AND TO MODIFY EXISTING ROOF MEMBRANE TO MAINTAIN ROOFING WARRANTY. DROP RETURN DUCTWORK AT 45° ANGLE DOWN TO 6 INCHES FROM LAY-IN CEILING TO BOTTOM OF DUCT. DROP RETURN DUCTWORK IN LOCATION SHOWN ON PLANS FOR LOW RETURN GRILLE. COORDINATE WITH THE GENERAL CONTRACTOR FOR THE REQUIRED FURR-OUT. 1 2 3 2 RT 10 4 44 COMMONS LOCATION 2 5 6 5 5 6 6 7 7 7 42x42" OA UPPH-1 EXIST 84x18" OA 8 8 1 NO SCALE CEILING MOUNTED EXHAUST FAN DETAIL EXHAUST DUCT (SEE PLAN FOR SIZE) CEILING GRILLE CEILING EXHAUST FAN FAN ASSEMBLY CABINET INSULATED ROOF INSTALL UNDER ROOF MEMBRANE AND SEAL WATERTIGHT BACK-DRAFT DAMPER ROOF CAP (FLAT ROOF) ROOF CURB WHERE REQUIRED BY ROOF MANUFACTURER D-3 580 HDHD HDHD HD HD HD HD 22x22" SA22x22" SA D-3 580 D-3 580 D-3 580 D-3 500 D-3 500 D-3 500 D-3 500 D-3 500 12"Ø SA 22 (ABOVE) 4 44 RT-10T 18 x 4 0 " R A 14x50" RA UP 14x50" SA UP 32x16" RA DN 9 9 3 10 10 RG-3 (LOW) 32x16" RA DN 10 RG-3 (LOW) HD HD 918 x 4 0 " R A 22x22" RA D-3 580 12"Ø SA12"Ø SA12"Ø SA12"Ø SA 12"Ø SA 12"Ø SA 12"Ø SA 12"Ø SA 12"Ø SA F: \ 2 2 \ 2 2 2 0 3 M a d i s o n J H S A d d i t i o n \ 2 2 2 0 3 M 2 . 0 1 . d w g A p r 1 9 , 2 0 2 3 - 3 : 4 6 p m Engineered Systems Associates Apr 19, 2023 ROOF TOP EXHAUST FAN DETAIL NO SCALE POWER EXHAUSTER BIRD SCREEN SECURE & CAULK TO CURB ROOFING BACKDRAFT DAMPER EXHAUST DUCT UP FROM BELOW, SIZE AS SHOWN ON PLANS FACTORY CURB TO MATCH ROOF SLOPE MAX. 1" 84" 60" 48" 36" 30" SIDE 10'-0" SPACING MAXIMUMHORIZONTAL SUPPORT ANGLE NONE REQUIRED 1-1/2"x1-1/2"x1/8" 2"x2"x1/8" 2"x2"x1/8" 2"x2"x1/8"3/8" ROUND ROD 5/16" ROUND ROD 1/4" ROUND ROD 1/4" ROUND ROD 1"x18 GAGE STRAP HANGER 8'-0" 8'-0" 8'-0" 8'-0" HANGER SIZES FOR RECTANGULAR DUCT DUCT STRAP HANGER DETAIL NO SCALE SUPPORT ANGLE (SEE SCHEDULE) HANGER ROD (SEE SCHED.) BOTTOM ANGLES OF ROOF JOIST NO POP RIVETS ALLOWED SELF TAPPING CADMIUM PLATED HEX HEAD SHEET METAL SCREW. STRAPS TO BE TIGHT AGAINST DUCT. HANGER STRAPS REINFORCING DUCT CONSTRUCTION AND HANGER DETAIL MENDED GAGE 24 26 DRIVE RECOM- SLIP NO SCALE 19 - 30 13 - 18 UP THRU 12 LONGEST INCHES SIDE, DIMENSION NONE REQUIRED26 NONE REQUIRED 1"x1"x1/8" @ 60 IN24 24 (ALL FOUR SIDES) OF GAGE METAL SHEET BETWEEN INTERMEDIATE REINFORCING JOINTS &/OR TRANSVERSE ANGLE SIZE SPACING LONGITUDINAL AND MAXIMUM 2"2" 26 MAX. 12" OC 24 24- S SLIP RECOM- MENDED GAGE HEMMED 1" TRANSVERSE REINFORCING (1) MINIMUM AT JOINTS (1) TRANSVERSE REINFORCING SIZE IS DETERMINED BY DIMENSION OF SIDE TO WHICH ANGLE IS APPLIED. GRIP NAILS SHALL BE INSTALLED BY GRIPNAIL AIR HAMMER OR BY AUTOMATIC FASTENER EQUIP. METAL FASTENERS - OMARK INSULPINS, DURO DYNE FASTENERS OR GRIPNAILS. STRAPS TO BE TIGHT AGAINST DUCTWORK HANG DUCTS UP TO 30" WIDTH WITH 1" x 18 GAGE STRAPS AT 10'-0" MAXIMUM SPACING. SELF-TAPPING CADMIUM PLATED HEX HEAD SHEET METAL SCREW NO POP RIVETS ALLOWED HANGER STRAPS SHEET METAL DUCT NOT MORE THAN 2" FROM EDGE OF LINER ALL ENDS OF LINER TO BE COATED WITH ADHESIVE. SEE SPECIFICATIONS. 1" THICK DUCT LINER TOP AND BOTTOM SECTION OF LINER SHALL OVERLAP THE SIDES ENDS OF LINER SHALL BE BUTTED FIRMLY TOGETHER LINER TO BE ADHERED TO DUCT W/100% ADHESIVE SEE SPECIFICATIONS. ROOFTOP HVAC UNIT DETAIL NO SCALE RELIEF AIR HOOD WHEN SPECIFIED ROOF SUPPLY AIR DUCTWORK RETURN AIR DUCTWORK. TURNING VANES CONDENSING SECTION ROOF STRUCTURE. REFER TO ARCHITECTURAL DRAWINGS FOR TYPE. PROVIDE HAIL GUARDS ON ALL UNITS. CONVERTIBLE PANELS FOR HORIZONTAL DUCTWORK. TYPICAL PACKAGED ROOF MOUNTED EQUIPMENT PROVIDE TRANSITIONS AS REQUIRED FOR CONNECTION FLEXIBLE DUCT CONNECTION OUTSIDE AIR INTAKE / ECONOMIZER HOOD PRE-FAB ROOF CURB. SHIM TO SIT LEVEL ON ROOF CEILING DIFFUSER DETAIL WITH FLEXIBLE DUCT NO SCALE HAND DAMPER HANDLE ROUND RIGID DUCT. WING NUT LAY-IN DIFFUSER LAY-IN CEILING DUCT SUPPORT 1" ACOUSTICAL DUCT LINER ON INTERIOR OF DUCT. 24" MAX TO FIRST SUPPORT RIGID SPIN- IN FITTING DUCT SUPPORT RECTANGULAR SUPPLY DUCT EXTERNAL DUCT INSULATION ON ALL ROUND RIGID DUCT- WORK AND FITTINGS. 24" MAX TO FIRST SUPPORT ROUND FLEXIBLE SUPPLY DUCT TO CEILING DIFFUSER 8'-0" MAX. LENGTH GLUE FLEX DUCT TO ADAPTER & CLAMP DOWN WITH STRAP. ROUND TO SQUARE TRANSITION OPPOSED BLADE DAMPER WHERE SPECIFIED ATTACH TO RIGID DUCT WITH DRAW BAND GLUE FLEX DUCT TO FITTING, CLAMP DOWN WITH STRAP AND SCREW SOLID TO RIGID FITTING FLEX DUCT SUPPORT DETAIL NO SCALE 2' - 0 " M A X I M U M FOOT OF SUPPORT SPACING. MAX. SAG 1/2" PER BAND CLAMP 1"x18 GAGE SECURE TO STRUCTURE. UNIT ROOFTOP ROOF CURB STRIP NAILING ROOF DECK JOISTS COUNTER FLASHING VERAL (TORCHED) PREPARED SURFACE SINGLE PLY ROOFING ASPHALT ROOFING MATERIAL SINGLE PLY CANT STRIP NEOPRENE WASHERS FASTENER WITH INSULATION RIGID ROOF DECK JOISTS OF HOW TRUSSES ARE RUNNING AS POSSIBLE REGARDLESS UNIT OVER AS MANY TRUSSES WEIGHT OF THE MECHANICAL MANNER AS TO SPREAD THE OVER ROOF JOISTS IN SUCH A POSITION ROOF CURB NOTE: NO SCALE TYPICAL ROOFTOP MOUNTING DETAIL PATTERN REMARKSMAX NC RATINGFINISHCONSTR.DAMPER BALANCINGCFM RANGESIZE THROW GRILLE AND REGISTER SCHEDULE SYM.TYPE STEELDIFFUSERD-1 24x24 250-350 20NOCFMWHITE STEELRETURN GRILLERG-1 20x48 1200 20NOWHITE PRICE MODEL 91SN/A STEELRG-2 24x24 820 20NOWHITEN/ARETURN GRILLE PRICE MODEL 535 IN 24x24" LAY-IN CEILING ALUMROOF CAPRC-1 120-200 N/AN/A8"Ø TWIN CITY MODEL 611CM WITH BIRDSCREENWHITE BRANCH 10"Ø DUCT PRICE MODEL SMD IN 24x24" LAY-IN CEILING 20x12" 8"Ø N/A STEELDIFFUSERD-2 12x12 190 30YESCFMWHITE10"Ø PRICE MODEL SMD IN BEVELED FRAME 12x12" EXHAUST FAN SCHEDULE REMARKSR.P.M.H.P.CHAR.CONTROLC.F.M.TYPE S.P.E.SYM.WEIGHT CEILING MOUNTED 195 TWIN CITY T2000.25 127 WATT 120/60/1 7402 EF N/A TIMER SWITCH WEIGHTSYM.EAT COOLING ROOFTOP HEATING & AIR CONDITIONING UNIT SCHEDULE MCOPH.P. BLOWER CHAR HEATING BTU OUTBTU IN LAT MBHEAT LAT REMARKSCFMGAS CONNSPE RT 1 MCA 900 LB 75°F301208/60/3 120,000 96,000 65°F 116°F 36,000 55°F12001/2".6"TRANE MODEL YHC036-E3 WITH INLET HOOD. MOUNT ON 14" HIGH PRE-FAB CURB.21.4 1 1 PROVIDE FACTORY MOUNTED 120 VOLT 1 PHASE, POWERED CONVENIENCE OUTLET AND BUILT-IN DISCONNECT ON EACH ROOF TOP UNIT. RT 5 THRU STEELEXHAUST GRILLEEG-1 150-350 YESN/A10x10 PRICE MODEL 535WHITE10"Ø N/A STEELEXHAUST GRILLEEG-2 70 YESN/A6x6 PRICE MODEL 535 WHITE 6"Ø N/A 2 PROVIDE WITH FACTORY HAIL GUARDS, 2" MERV 13 FILTER, & CO2 SENSOR WITH ROOF TOP UNIT. 2 RT 10 2015 LB 75°F1003208/60/3 320,000 284,000 65°F 110°F 194,000 55°F54003/4"1"TRANE MODEL GCC180A3EMD. MOUNT ON 14" HIGH PRE-FAB CURB. PROVIDE AND INSTALL WITH ECONOMIZER, BAROMETRIC RELIEF, AND SMOKE DETECTOR. 79 EF 1 ROOF MOUNTED TWIN CITY DCRU MODEL 110BE DIRECT DRIVE CENTRIFUGAL ALUMINUM WITH ROOF CURB. 620 0.5 0.5 120/60/1 1160 PROGRAMABLE160 LB DAYTIME TIMER RT 6 900 LB 75°F1208/60/3 120,000 65°F 116°F 36,000 55°F12001/2".6"TRANE MODEL YHC036-E3 WITH ECONOMIZER. MOUNT ON 14" HIGH PRE-FAB CURB. RT 7 900 LB 75°F1208/60/3 120,000 65°F 116°F 36,000 55°F12001/2".6"TRANE MODEL YHC036-E3 WITH INLET HOOD. MOUNT ON 14" HIGH PRE-FAB CURB. RT 9 THRU STEELRG-3 30x30 2700 25NOWHITEN/ARETURN GRILLE PRICE MODEL 9332x16" 3021.4 3021.4 STEELPH-1 48x48x38.5 14,000 N/ANOWHITEN/APENTHOUSE TWIN CITY MODEL TIL (MAX FPM: 600)OPENING PENTHOUSE DETAIL NO SCALE ROOF ROOFING STORM-PROOF LOUVER BLADES BIRDSCREEN LOUVERED PENTHOUSE WITH BIRDSCREEN AND WEATHER SHIELD. FACTORY CURB TO MATCH ROOF SLOPE TRANSITION DUCT AS REQUIRED TO CONNECT TO THROAT OPENING THROAT 42x42 INTAKE STEELPH-2 26x26x17.5 3,000 N/ANOWHITEN/APENTHOUSE TWIN CITY MODEL TIL (MAX FPM: 600)OPENING THROAT 20x20 INTAKE 3 INSTALL CONTROL MODULE INSIDE BUILDING AND NOT WITHIN THE ROOFTOP UNIT. 3OA 400 2200 400 400 96,000 96,000 STEELDIFFUSERD-3 24x24 500-600 20NOCFMWHITE12"Ø PRICE MODEL SMD IN 24x24" LAY-IN CEILING MMP TEP P.E. JOB #22133 Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 RE X B U R G , MA D I S O N S C H O O L D I S T R I C T # 3 2 1 ID A H O 890 APRIL '23 JU N I O R H I G H S C H O O L A D D I T I O N TO BE MOUNTED AS CLOSE TO TYPICAL DEVICE MOUNTING HEIGHTS DIAGRAM NO SCALE FINISHED FLOOR ARCHITECTURAL PLANS AND DETAILS. DOOR JAMBS AS POSSIBLE. COORDINATE ALL DEVICES WITH 1' - 6'' T.V. OUTLET ALL MOUNTING HEIGHTS TYPICAL UNLESS NOTED OTHERWISE. ALL SWITCHES AND THERMOSTATS NOTES: THERMOSTAT OR MECHANICAL SWITCH LIGHT SWITCH CONVENIENCE OUTLET TELEPHONE / DATA OUTLET T T (OR AS NOTED) 5' - 0'' 4' - 0'' 3' - 6'' A. COORDINATE OUTLET HEIGHTS WITH ARCHITECTS MILLWORK DWGS. TO INSURE THAT OUTLETS WILL NOT FALL BEHIND CABINETS, BACKSPLASHES, OR INTERFERE WITH WAINSCOTING, ETC. (OR AS NOTED) @ MILLWORK XX" B. D. COORDINATE LIGHT SWITCH & OUTLET HEIGHTS WITH ARCHITECTURAL WAINS- COTING AND OR TILE WORK SO AS NOT TO FALL MIDWAY IN THESE FINISHES. MOUNT VERTICAL OR HORIZONTAL TO MATCH EXISTING DEVICES (TYP) VERIFY WITH MECH. MUD RING ORIENTATION. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PREPARE ALL REQUIRED APPLICATIONS AND INFORMATION REQUIRED TO PROVIDE THE OWNER WITH THE MAXIMUM AMOUNT OF REBATE DOLLARS FROM THE LOCAL UTILITY COMPANY. THE ELECTRICAL CONTRACTOR SHALL SUBMIT VERIFICATION OF THE UTILITY COMPANY PRE-APPLICATION APPROVAL PRIOR TO ORDERING ANY MATERIALS. SPECIAL NOTE FOR UTILITY COMPANY LIGHTING REBATES & INCENTIVES: A.ELECTRICAL CONTRACTOR SHALL COORDINATE ALL LAMP TYPES WITH FIXTURE TYPE BEFORE ORDERING. B.ELECTRICAL CONTRACTOR SHALL REFER TO THE MECHANICAL DRAWINGS FOR EXACT LOCATION OF ALL MECHANICAL EQUIPMENT AND ELECTRICAL CONNECTIONS. C.ELECTRICAL CONTRACTOR SHALL PROVIDE MINIMUM WORKING CLEARANCE AS PER NEC BEFORE INSTALLING ANY ELECTRICAL PANELS FOR CABINETS. D.INSTALL ALL LIGHT FIXTURES IN MECHANICAL ROOM AFTER THE MECHANICAL EQUIPMENT IS IN PLACE, ADJUST AS NECESSARY. PROVIDE CHAIN SUSPENSION KITS AS REQUIRED. E.REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT FIXTURE LOCATIONS, CEILING TYPES, ETC. F.ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONCRETE PADS AS REQUIRED ON ALL ELECTRICAL EQUIPMENT. G.CONFIRM EXACT LOCATIONS OF ALL TELEPHONE / DATA OUTLETS WITH OWNER PRIOR TO ROUGH - IN. H.ELECTRICAL CONTRACTOR SHALL MOUNT SWITCHES AT 48" AND MOUNT CONVENIENCE OUTLETS AT 18" OR AS SHOWN ON PLANS TO MEET HANDICAPPED REQUIREMENTS. I.LOCATE SWITCHES, OUTLETS, ETC., SHOWN AT ROOM ENTRY DOORWAYS, AS CLOSE TO DOOR FRAME AS POSSIBLE, SO AS NOT TO INTERFERE WITH ROOM CABINETS, ETC. J.SUPPORT ALL LIGHT FIXTURES INDEPENDENT OF CEILING. K.ELECTRICAL CONTRACTOR SHALL OBTAIN ALL APPLICABLE PERMITS FOR THIS WORK AND PAY ASSOCIATED FEES. L.MAINTAIN 24" MIN. CLEARANCE FROM ALL COMMUNICATIONS CABLES AND ELECTRONIC BALLASTS. M.ALL BATTERY EXIT AND EMERGENCY LIGHTING TO BE CONNECTED TO THE UNSWITCHED LEG OF THE LIGHTING CIRCUIT IN THE AREA AS PER CODE. N.UNLESS SPECIFICALLY INDICATED OTHERWISE, THE ELECTRICAL CONTRACTOR TO COORDINATE WITH ANY SPECIAL SYSTEMS SUPPLIER /CONTR., EX. DENTAL, MEDICAL, KITCHEN,EQUIPMENT ETC. THE EXACT ROUGH-IN REQUIREMENTS FOR THERE EQUIPMENT. ALSO UNLESS INDICATED OTHERWISE, THE ELECTRICAL CONTR. TO BE RESPONSIBLE FOR FINAL CONNECTIONS TO ALL SPECIAL EQUIPMENT. O.ALL CONDUIT /RACEWAY /CABLES, TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. IF ANY SURFACE WORK IS NECESSARY, IT SHALL BE APPROVED BY THE ARCHITECT /ENGINEER PRIOR TO DOING ANY WORK. P.E.C. SHALL VISIT THE SITE PRIOR TO BID AND THOROUGHLY INVESTIGATE THE EXISTING CONDITIONS, AS THEY RELATE TO THE SCOPE OF WORK DESCRIBED. MAKE NECESSARY PROVISIONS IN THE BASE BID TO ADEQUATELY ACCOMMODATE THESE CONDITIONS. Q.JUNCTION BOXES FOR LIGHTING CIRCUITING ARE NOT SHOWN FOR CLARITY. THE E.C. IS RESPONSIBLE FOR PROVIDING AND INSTALLING ALL JUNCTION BOXES REQUIRED FOR CIRCUITING OF ALL LIGHT FIXTURES THAT ARE NOT LISTED FOR "THROUGH-BRANCH CIRCUIT WIRING". GENERAL NOTES:(ALL SHEETS) UL LISTED TAMPER RESISTANT DUPLEX RECEPTACLE WALL MOUNTED FIXTURE CEILING MOUNTED FIXTURE LIGHTING FIXTURE ELECTRICAL SYMBOL SCHEDULE BRANCH CIRCUIT - HOME-RUN TO PANEL BRANCH CIRCUIT - IN FLOOR OR UNDERGROUND MECHANICAL EQUIPMENT OR DETAIL SYMBOL DRAWING NOTE (ON THE SHEET WHERE SHOWN) FAN MOTOR CONNECTION POINT BRANCH CIRCUIT - CONCEALED * SEE MECHANICAL DRAWINGS FOR CONDUIT DESTINATION AND M.C. V.I.F. A.F.F. B.F.G. NL E.C. ABOVE FINISHED FLOOR BELOW FINISHED GRADE VERIFY IN FIELD NIGHT LIGHT (CONNECT TO UNSWITCHED LEG OF LTG CIRCUIT) MECHANICAL CONTRACTOR ELECTRICAL CONTRACTOR MOTOR CONNECTION POINT T EF TELEPHONE / DATA BOARD (GRND AS PER UTIL. CO) TIME CLOCK SWITCHT 1 1 A-1,3 UL LISTED TAMPER RESISTANT DOUBLE DUPLEX OUTLET (4-PLEX) JUNCTION BOX BRANCH PANELBOARD J EMERGENCY WALL LIGHT WITH 90MIN. BATTERY PHOTOELECTRIC CELL/SWITCHE WALL BOX DIMMER SWITCH. (SWITCH TO BE COMPAT. W/LOAD SERVED) SINGLE POLE SWITCH (SEE SUBSCRIPTS) RECESSED CAN FIXTURE MAIN/DISTRIBUTION PANELBOARD TRAC LIGHT SYSTEM PUSHBUTTON (AS INDICATED ON DRAWINGS) ROUGH-IN BOX MUD RING ORIENTATION. RECPT. SUB- SCRIPTS AC=ABOVE COUNTER GFI=GROUND-FAULT IG=ISOLATED GROUND S=SURGE SUPPRESSION TR=UL TAMPER RESISTANT WP=WEATHERPROOF COVER W/GFCI RECEPT. TV= RECPT. FOR TV, SEE ARCH. ELEVATION DWGS FOR MTG. HEIGHT USB=RECEPTACLE W/USB CHARGER CR=CORD REEL (SEE DETAIL) F=FUSED DISCONNECT (FUSE PER EQUIP. NAMEPLATE) DISCONNECT SWITCH (SIZE AND TYPE AS INDICATED) B=ENCLOSED CIRCUIT BREAKER CEILING MOUNTED DUPLEX RECEPTACLE FLOORBOX - POWER ONLY (2-DUPLEX RECEPTACLES) DUAL-LEVEL SWITCHES; IN-BOARD AND OUT-BOARD LAMPS SHALL BE SWITCHED SEPARATELY. (SUBSCRIPT APPLIES TO BOTH SWITCHES) SWITCH SUB- SCRIPTS 3 = 3-WAY 4 = 4-WAY F = EXHAUST FAN TIMER (INTERMATIC MODEL EI400 SERIES) T = THERMAL OVERLOAD SWITCH W/PILOT LIGHT P = 1-POLE SWITCH WITH PILOT LIGHT. (SEE SPECS) M = SWITCH SUPPLIED W/ EQUIPMENT (INSTALLED BY E.C.) WP = WEATHERPROOF EXIT SIGN, WALL OR CEILING MOUNT & DIRECTIONAL ARROWS AS INDICATED ON DRAWINGS. CONNECT TO UNSWITCHED LEG OF NEAREST LIGHTING CIRCUIT. EMERG. FIXTURE WITH EMERG. BATTERY PACK, CONNECTED TO UNSWITCHED LEG OF LIGHTING CIRCUIT. G.C.GENERAL CONTRACTOR N.T.S.NOT TO SCALE V=VFD (PROVIDED BY M.C. CONNECTED AND INSTALLED BY E.C.) COMBINATION STARTER & FUSED DISCONNECT SWITCH; 2-SETS OF NO/NC CONTACTS, CONTROL XFMR, FUSE PER EQUIP. NAMEPLATE CROSS LINES SHOW # OF PHASE/NEUTRAL CONDUCTORS IF MORE THAN TWO. EQUIPMENT/ISOLATED GROUNDING CONDUCTORS ARE NOT SHOWN. PROVIDE 'GREEN' EQUIP. GROUNDING CONDUCTOR FOR ALL CIRCUITS AND ADDITIONAL ISOLATED GROUND WHERE INDICATED. F M LED 0-10V: LEVITON RENOIR II #AWSMG-7D* W/MATCHING WALL PLATE (* COLOR TO MATCH WIRING DEVICES) F#EM NIGHT LIGHT FIXTURE, CONNECTED FIXTURE TO UNSWITCHED LEG OF LIGHTING CIRCUIT.NL DATA/COMM. SYMBOL SCHEDULE TELEPHONE OUTLET ( _=# OF CABLES, X=CONDUIT SIZE SEE BELOW) DATA OUTLET ( _=# OF CABLES, X=CONDUIT SIZE SEE BELOW) TELE/DATA OUTLET ( _=# OF CABLES, X=CONDUIT SIZE SEE BELOW) _T-X _D-X _T/_D-X TELEPHONE & DATA OUTLET NOTES: 1.UTILIZE 4 11/16" DEEP BOX WITH REQUIRED MUDRING AND CONDUIT TO COMMUNICATIONS BOARD, TERMINATE WITH INSULATED THROAT BUSHING. PROVIDE QTY OF CABLES INDICATED FROM OUTLET TO NEAREST TELE/DATA ROOM. SEE DWGS FOR ADDITIONAL INFORMATION. PROVIDE J-HOOKS 3FT ON CENTER ABOVE ACCESSIBLE CEILING FOR SUPPORT OF CABLING. 2.CONDUIT SIZES (X): 2=1/2", 3=3/4" , 4=1", 5=(2) 1" 3.NO LABEL INDICATES: 4 11/16" DEEP BOX WITH 1-GANG MUDRING AND 1" CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING OR CABLE TRAY. TERMINATE WITH INSULATED THROAT BUSHING (UNO). PROVIDE WITH PULL STRING. 4.INSTALL CABLES TO NEAREST IT ROOM. DATA OUTLET - ABOVE CEILING ( _=# OF CABLES)_D LARGE CAPACITY BOX (C = CEILING MOUNTED) LARGE CAPACITY 2 GANG J-BOX (HUBBELL HBL260) WITH 1 GANG MUDRING AND VANCO 1 GANG CABLE EXIT BRUSH WALL PLATE (VAN 12081). INSTALL A 1 1/2" CONDUIT TO ABOVE ACCESSIBLE CEILING OR TO A CEILING MOUNTED BOX IN HARD CEILING APPLICATION. INSTALL AS DIRECTED BY OWNER. COMMUNICATIONS CABLING REQUIREMENTS: (SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION) NETWORK CABLING - CAT6 PLENUM RATED, BLUE TELEPHONE CABLING - CAT6 PLENUM RATED, YELLOW OBTAIN COLOR SELECTED BY OWNER PRIOR TO ORDERING. S HVAC THERMOSTAT OR SENSOR; E.C. SHALL PROVIDE ROUGH-IN INCLUDING BACK-BOX, MUD-RING AND 3/4" CONDUIT & PULL STRING TO ASSOCIATED HVAC UNIT. COORDINATE EXACT LOCATIONS WITH MECH. DWGS.* E1.0 EL E C T R I C A L N O T E S A N D S C H E D U L E S LED SURFACE WRAP INCLUDED LITHONIA BLWP4 4000LM LP840 MIN1 EZ1 MVOLTCEILING120/277 ADP FIXTURE NOTES: LIGHT FIXTURE SCHEDULE RECESSED CAN LIGHT LED (NO LENS) RECESSED 120/277 LED LITHONIA LDN6-40-15-L06-AR-LSS-MVOLT-EZ10 LED STRIP INCLUDED LITHONIA CLX-L48-4000LM-SEF-RDL-MVOLT-GZ10120/277CEILING -40K-80CRI-CBA WALL MOUNTED LED VARIABLE LENGTHS WALL PER ARCH 120/277 LED PRIMUS ALX2 RLR LED-H-40K-UNV-SM- (SEB,SEK,SBEK)-#-LENGTH AS INDICATED 1 CONNECT ALL EXIT AND EMERGENCY LIGHTS TO UNSWITCHED LEG OF LIGHTING CIRCUIT IN AREA. 2 THE SUFFIX "EM" DENOTES A FIXTURE TO BE SUPPLIED WITH AN EMERGENCY BATTERY DRIVER. CONNECT FIXTURES TO OPERATE WITH SURROUNDING FIXTURES UNDER NORMAL OPERATING CONDITIONS. EC SHALL VERIFY FIXTURE COMPATIBILITY PRIOR TO ORDERING. 3 THIS FIXTURE WILL NOT COVER A J-BOX. EC SHALL WHIP FEED FOR A CLEAN INSTALLATION. EC SHALL ALSO PROVIDE ARCHITECTURAL ENDCAPS WHERE FIXTURE DOES NOT END IN A WALL AND WILL FUNCTION AS A NIGHT LIGHT. 4 EC SHALL PROVIDE AND INSTALL ALL REQUIRED SWITCHLEGS, 0-10V DIMMING CABLE, OR NLIGHT CAT 5E CABLE TO ACHIEVE SPECIFIED LIGHTING CONTROL. INSTALL ALL CABLE IN CONDUIT. 1 2 3 4 PROVIDE WITH ARCH ENDCAPS WHERE NECESSARY. 2x2 LED LAY-IN GRID RECESSED INCLUDED LITHONIA CPANL 2X2 24/33/44LM 40K-M4120/ 277ADJUSTABLE LUMENS LED WALL MOUNTED FLOOD LIGHT INCLUDED LITHONIA OLX1LED 20W40K DDBWALL PER ARCH 120/277 WALL OR CEILING BATTERY POWERED EXIT SIGN INCLUDED120 LITHONIA LHQM LED G HO SDWITH REMOTE EXTERIOR HEAD ELA QWP LO309 SD 1 #2 MULTI SERVICE FLOOR BOX: HUBBELL 10GANG WITH BOX, COVER AND DEVICES. PROVIDE WITH (5) DUPLEX RECEPTACLES AND (2) 1 1/2" CONDUITS TO ABOVE ACCESSIBLE CEILING MULTI SERVICE FLOOR BOX: HUBBELL 6GANG WITH BOX, COVER AND DEVICES. PROVIDE WITH (2) DUPLEX RECEPTACLES AND (2) 1" CONDUITS TO ABOVE ACCESSIBLE CEILING SPEAKER/CLOCK AND CALL STATION. PROVIDE ROUGH-IN PER TYPICAL CLASSROOM DETAIL SHEET E2.2 5 PROVIDE FIXTURE LENGTH AS SHOWN ON DRAWINGS. 5 ROUGH-IN FOR OWNER FURNISHED PA SYSTEM. 4 SQ. BOX WITH SINGLE GANG MUD RING WITH 3/4" CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING OR CABLE TRAY. COORDINATE WITH OWNER PRIOR TO ROUGH-IN. SAME AS F1 EXCEPT SUSPENDED LEVEL WITH BOTTOM OF TRUSS. 2x4 LED LAY-IN GRID RECESSED INCLUDED LITHONIA CPANL 2X440/50/60LM 40K-M2120/ 277ADJUSTABLE LUMENS SUSPENDED SAME AS F1 EXCEPT RECESSED IN SUSPENDED HARD LID RECESSED 2000 SQ D NQOD 120/208V 3Ø 4W LIGHTING - 1000 20 1 1500 "N1" 20"x39"x5 3/4" 20 2000 1 500 CLASS RECEPTACLES 225 15000 125 SEE RISER 125 15000 125 15000 SEE RISER DETERMINED TO BE B MAIN BRKR. AMPS LOAD/POLE MAIN LUGS ONLY 19 FEEDER CONDUCTOR SIZE: TOTAL LOAD/PHASE REMARKS: AMPS WATTS 41 29 37 39 35 33 31 27 25 21 23 CLASS LOCATION MAKE/MODEL LOAD NAME AAMPWATTSNO. 9 17 15 11 13 7 5 1 3 E BRKCIRLOAD MAIN SW. OP L 20 S.C. INT CAP/BKR. 40 CONDUIT SIZE 42 30 38 36 34 32 28 26 24 22 AMPS. NO.WATTSECAMP 10 18 16 14 12 8 6 2 4 FEED BOTTOM FEED TOP DIMENSIONS BRK AMPS LOP LOAD CIR SURFACE FLUSH LOAD NAME SUPPLY WITH INTEGRAL SPD. 1500 1500 SPARE CORR LIGHTING CLASS RECEPTACLES SPARE RT/7 20 2 -- 30 3 -- -- - - - RT/8 30 3 -- -- - - 1500 500 2000 500 500 2000 2000 2000 2000 2000 303 2000 RT/1 --2000 --2000 - - 303 2000 RT/3 --2000 --2000 - - 303 2000 RT/5 --2000 --2000 - - 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 1000 2000 1000 3000 2500 3000 4000 4000 4000 4000 4000 4000 1500 SQ D NQOD 120/208V 3Ø 4W LIGHTING - 1500 20 1 2000 "N2" 20"x39"x5 3/4" 20 500 1 500 CLASS RECEPTACLES 225 13000 108 SEE RISER 104 12500 100 12000 SEE RISER DETERMINED TO BE B MAIN BRKR. AMPS LOAD/POLE MAIN LUGS ONLY 19 FEEDER CONDUCTOR SIZE: TOTAL LOAD/PHASE REMARKS: AMPS WATTS 41 29 37 39 35 33 31 27 25 21 23 CLASS LOCATION MAKE/MODEL LOAD NAME AAMPWATTSNO. 9 17 15 11 13 7 5 1 3 E BRKCIRLOAD MAIN SW. OP L 20 S.C. INT CAP/BKR. 40 CONDUIT SIZE 42 30 38 36 34 32 28 26 24 22 AMPS. NO.WATTSECAMP 10 18 16 14 12 8 6 2 4 FEED BOTTOM FEED TOP DIMENSIONS BRK AMPS LOP LOAD CIR SURFACE FLUSH LOAD NAME SUPPLY WITH INTEGRAL SPD. (1) GFCI BREAKER. 1000 SPARE CLASS RECEPTACLES RT/6 30 3 -- -- - - RT/9 30 3 -- -- - - 500 2000 500 500 2000 2000 2000 2000 2000 SPARE 303 2000 RT/2 --2000 --2000 - - 303 2000 RT/4 --2000 --2000 - - 500 500 500 500 500 500 500 500 1000 1000 500 500 1000 1000 1000 500 1500 1000 1500 500 500 500 4000 4000 4000 4000 4000 4000 LIGHTING 500 500 500 500 500 500 500 RECEPTACLES SPARE ELECT. WATER COOLER (1) ROOF RECEPTACLES EF/1 WALL MOUNTED EGRESS LIGHT INCLUDED LITHONIA ELM6L-LTPWALL +8 FT.120/277 1 EXISTING ELECTRICAL ROOM EXISTING SWITCHGEAR (SQ.-D). PROVIDE AND INSTALL (2) 200A 3P BREAKERS IN EXISTING SWITCHBOARD FOR NEW PANELS-"N1" AND "N2". EXISTING IT ROOM FA NAC PANELS FACP "N2" "N1" PROVIDE AND INSTALL (2) 3"C., 4-#250AL + GROUND TO NEW BREAKERS IN MAIN PANEL. FIELD VERIFY BEST ROUTING. CORE DRILL ALL REQUIRED WALL PENETRATIONS. SEAL WALL AROUND CONDUIT. EXISTING PANEL-"K" EXISTING PANEL-"K1" 1 2 NEW COMMONS ADDITION MMP TEP P.E. JOB #22133 Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 RE X B U R G , MA D I S O N S C H O O L D I S T R I C T # 3 2 1 ID A H O 890 APRIL '23 JU N I O R H I G H S C H O O L A D D I T I O N E1.1 OV E R A L L P L A N E L E C T R I C A L SCALE: OVERALL FLOOR PLAN - ELECTRICAL 1" = 20' - 0"20'0"40'10' N KEY NOTES 1 PROVIDE AND INSTALL (3) 20A 1P TANDEM BREAKERS IN EXISTING PANEL-"K" (SQ-D). PROVIDE NEW PANEL INDEX TO REFLECT CURRENT LOAD. PROVIDE AND INSTALL (1) 100A 3P AND (1) 20A 3P IN EXISTING PANEL-"K1" (SQ-D). PROVIDE NEW PANEL INDEX TO REFLECT CURRENT LOAD. 2 CLASS 103 CLASS 104 CLASS 105 CLASS 106 CLASS 107 CLASS 120 CLASS 118 CLASS 110 CORR 102 CORR 101 CORR 114 CORR 109 CUST 113 STOR 119 TR 117 TR 115 TR 112 TR 111 VEST 108 S S S S S S D F8 F8 SS S S S S S F8 S 3 9 3 9 3 9 3 9 SEE TYPICAL CLASSROOM DETAIL "B", SHEET E2.2 LIGHTING CIRCUIT: N2-1 SEE TYPICAL CLASSROOM DETAIL "B", SHEET E2.2 LIGHTING CIRCUIT: N2-1 SEE TYPICAL CLASSROOM DETAIL "B", SHEET E2.2 LIGHTING CIRCUIT: N2-3 SEE TYPICAL CLASSROOM DETAIL "A", SHEET E2.2 LIGHTING CIRCUIT: N1-1 SEE TYPICAL CLASSROOM DETAIL "A", SHEET E2.2 LIGHTING CIRCUIT: N1-1 SEE TYPICAL CLASSROOM DETAIL "A", SHEET E2.2 LIGHTING CIRCUIT: N1-3 SEE TYPICAL CLASSROOM DETAIL "A", SHEET E2.2 LIGHTING CIRCUIT: N1-3 SEE TYPICAL CLASSROOM DETAIL "A", SHEET E2.2 LIGHTING CIRCUIT: N1-3 F7EM F7EM F7EM F7EM F5 F7 (TYP)F7 (TYP) F7 (TYP) F7EM 5 F9 (TYP) F9 F9 F8 F8 F8 F8 F8 F8 F10 F10 F7 CIRCUIT: N1-19 CIRCUIT: N1-19 CIRCUIT: N1-19 N1-5 F11 F11 MMP TEP P.E. JOB #22133 Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 RE X B U R G , MA D I S O N S C H O O L D I S T R I C T # 3 2 1 ID A H O 890 APRIL '23 JU N I O R H I G H S C H O O L A D D I T I O N E2.0 CL A S S R O O M L I G H T I N G P L A N SCALE: CLASSROOM ADDITION - LIGHTING 1/8" = 1' - 0"16'8'0" N LIGHTING KEY NOTES 1 CONNECT ALL DIMMING POWER PACKS, SENSORS AND WALL DEVICES WITH CAT 5e CABLE COLOR TO MATCH STRUCTURE. PROVIDE ALL 0-10V WIRING AND POWER CIRCUIT FROM EACH FIXTURE TO POWER PACK IN 1/2" CONDUIT. CONNECT TO EXISTING EXTERIOR LIGHTING CIRCUIT AND CONTROLS. CONNECT OCC. SENSORS IN THIS ROOM IN PARALLEL SUCH THAT ANY SENSOR WILL ACTIVATE ALL LIGHTING IN ROOM. NOTE NOT USED. CONTROL VESTIBULE LIGHTS WITH DAYLIGHT SENSOR. PROVIDE ALL REQUIRED POWER POWER PACKS, SENSOR, 0-10V WIRING, ETC. FIXTURES TO RAMP UP AND DOWN BASED ON AMBIENT LIGHT. E.C. SHALL PROVIDE STRUCTURE NECESSARY TO RIGIDLY MOUNT RECESSED CAN IN CANOPY. COORDINATE WITH ARCH. DETAILS AND G.C. SEE DETAIL "B" SHEET E2.3 FOR WIRING INFORMATION IN THIS ROOM. SEE DETAIL "C" SHEET E2.3 FOR WIRING INFORMATION IN THIS ROOM. SEE DETAIL "D" SHEET E2.3 FOR WIRING INFORMATION IN THIS ROOM. SEE DETAIL "A" SHEET E2.3 FOR WIRING INFORMATION IN THIS ROOM. NOTE NOT USED. CONTROL DOWN LIGHTS WITH CORRIDOR FIXTURES. SEE DETAIL "A" SHEET E2.2 FOR WIRING INFORMATION IN THIS ROOM. SEE DETAIL "B" SHEET E2.2 FOR WIRING INFORMATION IN THIS ROOM. CONNECT TO SPARE 20A 1P BREAKERS IN EXISTING PANEL-"K" 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SD 2 2 5 S PPD F4 F4 PPD 1 S S S S S F3 F6 F3 F6 F5 COMMONS 139 VEST 140 15 1 F7 (TYP) F7EM (TYP) F7EM F7EM MMP TEP P.E. JOB #22133 Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 RE X B U R G , MA D I S O N S C H O O L D I S T R I C T # 3 2 1 ID A H O 890 APRIL '23 JU N I O R H I G H S C H O O L A D D I T I O N E2.1 CO M M O N S L I G H T I N G P L A N SCALE: COMMONS ADDITION - LIGHTING 1/8" = 1' - 0"16'8'0" N LIGHTING KEY NOTES 1 CONNECT ALL DIMMING POWER PACKS, SENSORS AND WALL DEVICES WITH CAT 5e CABLE COLOR TO MATCH STRUCTURE. PROVIDE ALL 0-10V WIRING AND POWER CIRCUIT FROM EACH FIXTURE TO POWER PACK IN 1/2" CONDUIT. CONNECT TO EXISTING EXTERIOR LIGHTING CIRCUIT AND CONTROLS. CONNECT OCC. SENSORS IN THIS ROOM IN PARALLEL SUCH THAT ANY SENSOR WILL ACTIVATE ALL LIGHTING IN ROOM. NOTE NOT USED. CONTROL VESTIBULE LIGHTS WITH DAYLIGHT SENSOR. PROVIDE ALL REQUIRED POWER POWER PACKS, SENSOR, 0-10V WIRING, ETC. FIXTURES TO RAMP UP AND DOWN BASED ON AMBIENT LIGHT. E.C. SHALL PROVIDE STRUCTURE NECESSARY TO RIGIDLY MOUNT RECESSED CAN IN CANOPY. COORDINATE WITH ARCH. DETAILS AND G.C. SEE DETAIL "B" SHEET E2.3 FOR WIRING INFORMATION IN THIS ROOM. SEE DETAIL "C" SHEET E2.3 FOR WIRING INFORMATION IN THIS ROOM. SEE DETAIL "D" SHEET E2.3 FOR WIRING INFORMATION IN THIS ROOM. SEE DETAIL "A" SHEET E2.3 FOR WIRING INFORMATION IN THIS ROOM. NOTE NOT USED. CONTROL DOWN LIGHTS WITH CORRIDOR FIXTURES. SEE DETAIL "A" SHEET E2.2 FOR WIRING INFORMATION IN THIS ROOM. SEE DETAIL "B" SHEET E2.2 FOR WIRING INFORMATION IN THIS ROOM. CONNECT TO SPARE 20A 1P BREAKERS IN EXISTING PANEL-"K" 2 3 4 5 6 7 8 9 10 11 12 13 14 15 MMP TEP P.E. JOB #22133 Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 RE X B U R G , MA D I S O N S C H O O L D I S T R I C T # 3 2 1 ID A H O 890 APRIL '23 JU N I O R H I G H S C H O O L A D D I T I O N E2.2 TY P I C A L C L A S S R O O M E L E C T R I C A L J J J 4 1 1 5 2 3 J 6 J J 3 4 1 J6 2 5 KEY NOTES 1 LARGE CAPACITY 2-GANG J-BOX (HUBBELL #HBL260) WITH 2-GANG MUD RING AND VANCO 2-GANG CABLE. EXIT BRUSH WALL PLATE (VAN #12082) INSTALL A 1 1/2" CONDUIT TO ABOVE ACCESSIBLE CEILING FOR USE BY OWNER. MOUNT DEVICE IN ARCH. MILLWORK. E.C. SHALL COORDINATE WITH MILLWORK DETAILS PRIOR TO ROUGH-IN. PROVIDE AND INSTALL A DEDICATED 4-PLEX RECEPTACLE AT 52" AFF FOR LAP TOP CHARGING STATION. COORDINATE INSTALLATION WITH MILLWORK SHOP DRAWINGS. PROVIDE AND INSTALL A DUPLEX RECEPTACLE AND A 4" SQ. L-BOX WITH SINGLE GANG MUD RING, BRUSH COVER PLATE AND A 3/4" CONDUIT WITH PULL CORD TO ABOVE CEILING AREA, TO BE ACCESSIBLE FROM TOP SHELF OF WARDROBE CLOSET. COORDINATE WITH ARCH. MILLWORK. COORDINATE INSTALLATION WITH PROJECTOR MOUNTING HARDWARE. PROVIDE AND INSTALL 120V. ABOVE CEILING FOR FUTURE USE. 4 SQ. BOX WITH SINGLE GANG MUD RING FOR OWNER FURNISHED CALL SWITCH. 4 SQ. BOX WITH HORIZONTAL SINGLE GANG MUD RING FOR SPEAKER/CLOCK. 2 3 4 5 6 NO SCALE TYPICAL CLASSROOM "A" - ELECTRICAL (REFER TO LIGHTING DRAWINGS) NO SCALE TYPICAL CLASSROOM "B" - ELECTRICAL (REFER TO LIGHTING DRAWINGS) 7 8 3 S S PPD OCCUPANCY SENSOR(S) PER LTG DRAWINGS ENTRY SWITCH(ES) nPODM-DX-X SEE PLAN FOR CIRCUIT PROVIDE 24" SLACK CABLE BETWEEN ALL CONNECTIONS FOR CEILING TILE ACCESS CAT-5e CABLE TYPICAL TYPICAL 0-10V WIRING AND ON/OFF SWITCH LEG IN 1/2" CONDUIT F1 (TYP) 3 S PPD SEE PLAN FOR CIRCUIT S F1 (TYP) PROVIDE 24" SLACK CABLE BETWEEN ALL CONNECTIONS FOR CEILING TILE ACCESS CAT-5e CABLE TYPICAL ENTRY SWITCH(ES) nPODM-DX-X OCCUPANCY SENSOR(S) PER LTG DRAWINGS TYPICAL 0-10V WIRING AND ON/OFF SWITCH LEG IN 1/2" CONDUIT 2 3 1 4 2 3 1 4 CAT 5e CABLE O-10V. WIRING LINE VOLTAGE WIRING CAT 5e CABLE O-10V. WIRING LINE VOLTAGE WIRING L L L L L L L L L L L L ELEVATION - 1 ELEVATION - 2 ELEVATION - 3 ELEVATION - 4 ELEVATION - 1 ELEVATION - 2 ELEVATION - 3 ELEVATION - 4 1 1/2" C.1 1/2" C. 18" 1 DATA POWER DATA POWER 1 1 1/2" C. 18" 48" 3/4" C. 1/2" C. SPEAKER/ CLOCK 8 77'-6" E.C. SHALL COORDINATE EXACT PROJECTOR PLACEMENTS WITH OWNER PRIOR TO ROUGH-IN 44" LIGHT CONTROL 3/4" C. E.C. SHALL PROVIDE AND INSTALL (4) 8 OUTLET, 24" LONG PLUG STRIP AT EACH CHARGING CABINET. MOUNT ON FRONT OF SHELF AS DIRECTED BY OWNER AND ARCHITECT. PLUG STRIP SUCH AS TRIPPLITE #PS240810 LIGHT CONTROL 3/4" C. E.C. SHALL PROVIDE AND INSTALL (4) 8 OUTLET, 24" LONG PLUG STRIP AT EACH CHARGING CABINET. MOUNT ON FRONT OF SHELF AS DIRECTED BY OWNER AND ARCHITECT. PLUG STRIP SUCH AS TRIPPLITE #PS240810 44" 1 1/2" C. 18" 48" 3/4" C. 1/2" C. SPEAKER/ CLOCK 8 77'-6" E.C. SHALL COORDINATE EXACT PROJECTOR PLACEMENTS WITH OWNER PRIOR TO ROUGH-IN 1 1/2" C. 18" 1 DATA POWER MMP TEP P.E. JOB #22133 Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 RE X B U R G , MA D I S O N S C H O O L D I S T R I C T # 3 2 1 ID A H O 890 APRIL '23 JU N I O R H I G H S C H O O L A D D I T I O N E2.3 TY P I C A L L I G H T I N G D E T A I L S LIGHTING CONTROL SCHEDULE ON/OFF/DIM PUSHBUTTON SENSOR SWITCH nPODM-DX-CBA PS 1 ON/OFF/DIM/DUAL TECH OCC SENSOR SENSOR SWITCH nWSXPDTLV-DX-CBA2 DUAL TECHNOLOGY OCCUPANCY SENSOR SENSOR SWITCH nCMPDT9ADCS INFRARED OCCUPANCY SENSOR SENSOR SWITCH nCM10SH 4UTP CAT 5e PATCH CORD SENSOR SWITCH PS150 SUPPLY & INSTALL AS REQ'D.POWER SUPPLY SENSOR SWITCH nPP16-D PP RELAY POWER PACK, 0-10V DIMMING PATCH CORDS SHALL BE RATED FOR THE SPACE INSTALLED (PLENUM) 3 S L S D DAYLIGHT SENSOR SENSOR SWITCH nCM ADC LARGE AREA INFRA RED SENSOR SENSOR SWITCH nCM62P ON/OFF PUSHBUTTON SENSOR SWITCH nPODM-CBA (USE BETWEEN ALL LIGHTING NETWORK DEVICES & nLIGHT FIXTURES) 1, 2, 3 NOTES: 1.ALL LIGHTING CONTROL CABLE SHALL BE WHITE IN COLOR. 2.ALL CABLE NOT INSTALLED CONCEALED ABOVE ACCESSIBLE CEILING, SHALL BE INSTALLED IN 3/4" CONDUIT. 3.PROVIDE A MIMIMUM OF 2' SLACK BETWEEN ALL DEVICE AND FIXTURE CONNECTION POINTS. 4SQ. BOX W/ SINGLE GANG MUD RING W/ 3/4" C., TO ABOVE ACCESSIBLE CEILING OR NEXT DEVICE SEE DETAILS THIS SHEET SENSOR SWITCH nPP16 PPD RELAY POWER PACK S LINE-VOLTAGE, DUAL-TECH OCC. SENSOR SENSOR SWITCH CMR PDT 9 S LINE-VOLTAGE, DUAL-TECH OCC. SENSOR SENSOR SWITCH CMR PDT 9 ADC W/ PHOTOCELL & 0-10V DIMMING P S RESTROOM ,LINE VOLTAG, DUAL-TECH SENSOR SWITCH CMR PDT 9 2P 2-POLE OCC. SENSOR. R (1) RELAY FOR LTG, (1) RELAY FOR EXHAUST FAN CONTROL SET TO 30 MIN. DELAY. SEE DETAILS THIS SHEET 4 TWO CHANNEL ON/OFF/DIM PUSHBUTTON SENSOR SWITCH nPODM-2P-DX-CBA 5 FOUR CHANNEL ON/OFF/DIM PUSHBUTTON SENSOR SWITCH nPODM-4P-DX-CBA SPECIAL LIGHTING CONTROL NOTES: E.C. SHALL PROVIDE AND INSTALL CAT5e PLENUM RATED PATCH CORDS FROM CONTROL DEVICE TO CONTROL DEVICE PER MANUFACTURER'S RECOMMENDATIONS. PROVIDE 2FT. SLACK CABLE BETWEEN ALL CAT 5E CONNECTIONS TO DEVICES. PROGRAM DEVICE OPERATION TO OWNER'S SATISFACTION. 1. 2. 3. GENERAL NOTES: THIS DIAGRAM IS SCHEMATIC IN NATURE; REFER TO LIGHTING DRAWINGS FOR EXACT QTY AND LOCATION OF OCC. SENSORS, DAY-LIGHT SENSORS, WALL SWITCHES AND LIGHT FIXTURES NO SCALE TYP. ROOM CONTROL DIAGRAMS - ON/OFF/DIM CONTROL 3 ENTRY SWITCH(ES) nPODM-DX-X PROVIDE 24" SLACK CABLE BETWEEN ALL CONNECTIONS FOR CEILING TILE ACCESS S TYPICAL FIXTURE OCCUPANCY SENSOR(S) PER LTG DRAWINGS ORIENT LIGHTS AS SHOWN ON DRAWINGS CAT-5e CABLE TYPICAL 3 PPD TYPICAL 0-10V WIRING & ON/OFF SWITCH LEG PPD - nLIGHT RELAY POWER PACK W/ 0-10V DIMMING (SEE LIGHTING CONTROL SCHEDULE) NO SCALE TYP. CORRIDOR/COMMON AREA CONTROL DIAGRAMS GENERAL NOTES: THIS DIAGRAM IS SCHEMATIC IN NATURE; REFER TO LIGHTING DRAWINGS FOR EXACT QTY AND LOCATION OF OCC. SENSORS, DAY-LIGHT SENSORS, WALL SWITCHES AND LIGHT FIXTURES S TYPICAL LUMINAIRE OCCUPANCY SENSOR(S) PER DRAWINGS EMERG. FIXTURE(S) AS PER DWGS, CONNECTED TO UNSWITCHED LEG OF LIGHTING CIRCUIT FIXTURE TO OPERATE WITH OTHER FIXTURES ON NORMAL CONDITIONS.. S (REFER TO LIGHTING DRAWINGS) PP PP - nLIGHT RELAY POWER PACK W/ 0-10V DIMMING (SEE LIGHTING CONTROL SCHEDULE) TO ADDITIONAL nLIGHT DEVICES IN CONTROL ZONE AS APPLICABLE. TO ADDITIONAL FIXTURES IN CONTROL ZONE TO ADDITIONAL FIXTURES IN CONTROL ZONE TYPICAL ON/OFF SWITCH LEG IN 1/2" CONDUIT NO SCALE TYPICAL POWER PACK DETAIL nPP16D CAT-5e N H N 0-10 V LED DRIVER BLU BLK/ORN WHT GRN GRY VIO BLU PPD 2 PPD2 NO SCALE TYP. OFFICE CONTROL DIAGRAM (REFER TO LIGHTING DRAWINGS) TYPICAL 0-10V WIRING AND ON/OFF SWITCH LEG IN 1/2" CODNUIT ON/OFF/DIM DUAL TECH. OCC. SENSOR (REFER TO LIGHTING DRAWINGS) LINE VOLTAGE CIRCUIT SEE PLAN SENSOR SWITCH nEPP5 D KO5 AMP RELAY DIMMING POWER PACKPPD2 TYPICAL CAT5e CABLE A B C D N TO NEXT FIXTURE IN THE EVENT THAT FIXTURES IN DAYLIGHT ZONES ARE CONTROLLED BY (2) DIFFERENT RELAY POWER PACKS, PROVIDE A 2 POLE SINGLE THROW "DAYLIGHT ZONE" SWITCH AND ROUTE SWITCH LEGS FOR EACH RELAY CAT 5e CABLE (WHITE) O-10V. WIRING LINE VOLTAGE WIRING CAT 5e CABLE (WHITE) O-10V. WIRING LINE VOLTAGE WIRING SEE PLAN FOR CIRCUIT CAT 5e CABLE (WHITE) O-10V. WIRING LINE VOLTAGE WIRING S WALL OCC. SENSOR (ON/OFF)SENSOR SWITCH WSXPDT-CBAW S 2-POLE WALL OCC. SENSOR (ON/OFF)SENSOR SWITCH WSXPDT2P-CBAW2 EMERG. FIXTURE(S) AS PER DWGS, CONNECTED TO UNSWITCHED LEG OF LIGHTING CIRCUIT FIXTURE TO OPERATE WITH OTHER FIXTURES ON NORMAL CONDITIONS. 0-10 V LED DRIVER LIGHTING COMMISSIONING NOTE: E.C. SHALL PROVIDE FACTORY CERTIFIED COMMISSIONING OF ALL LIGHTING CONTROL SYSTEMS. E.C. SHALL PROVIDE FACTORY CERTIFIED ON-SITE TRAINING FOR ALL LIGHTING CONTROL SYSTEMS. TRAINING MUST BE VIDEO RECORDED AND TURNED OVER TO OWNER FOR FUTURE REFERENCE. E.C. SHALL FIELD ADJUST LUMEN VALUES OF ALL F2, F11 AND F14 FIXTURES TO SATISFACTION OF OWNER AND ENGINEER. 4.THESE PRODUCTS CONSTITUTE THE BASIS OF DESIGN. EQUAL SOLUTIONS BY COOPER AND WATTSTOPPER ARE ACCEPTABLE. CLASS 103 CLASS 104 CLASS 105 CLASS 106 CLASS 107 CLASS 120 CLASS 118 CLASS 110 CORR 102 CORR 101 CORR 114 CORR 109 CUST 113 STOR 119 TR 117 TR 115 TR 112 TR 111 VEST 108 SEE TYPICAL CLASSROOM DETAIL "A", SHEET E2.2 POWER CIRCUITS: N1-2,4,6 SEE TYPICAL CLASSROOM DETAIL "A", SHEET E2.2 POWER CIRCUITS: N1-8,10,12 SEE TYPICAL CLASSROOM DETAIL "A", SHEET E2.2 POWER CIRCUITS: N1-14,16,18 SEE TYPICAL CLASSROOM DETAIL "A", SHEET E2.2 POWER CIRCUITS: N1-20,22,24 SEE TYPICAL CLASSROOM DETAIL "A", SHEET E2.2 POWER CIRCUITS: N1-21,23,25 SEE TYPICAL CLASSROOM DETAIL "B", SHEET E2.2 POWER CIRCUITS: N2-8,10,12,14,16 SEE TYPICAL CLASSROOM DETAIL "B", SHEET E2.2 POWER CIRCUITS: N2-11,13,15,17,19 SEE TYPICAL CLASSROOM DETAIL "B", SHEET E2.2 POWER CIRCUITS: N2-21,23,25,27,29 "N1" "N2" N2-20 N2-2,4,6 MMP TEP P.E. JOB #22133 Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 RE X B U R G , MA D I S O N S C H O O L D I S T R I C T # 3 2 1 ID A H O 890 APRIL '23 JU N I O R H I G H S C H O O L A D D I T I O N E3.0 CL A S S R O O M P O W E R P L A N SCALE: CLASSROOM ADDITION - POWER 1/8" = 1' - 0"16'8'0" N POWER KEY NOTES 1 CONNECT TO 20A 1P BREAKERS IN EXISTING PANEL-'K". COMMONS 139 VEST 140 1 MMP TEP P.E. JOB #22133 Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 RE X B U R G , MA D I S O N S C H O O L D I S T R I C T # 3 2 1 ID A H O 890 APRIL '23 JU N I O R H I G H S C H O O L A D D I T I O N E3.1 CO M M O N S P O W E R P L A N SCALE: COMMONS ADDITION - POWER 1/8" = 1' - 0"16'8'0" N POWER KEY NOTES 1 CONNECT TO 20A 1P BREAKERS IN EXISTING PANEL-'K". CLASS 103 CLASS 104 CLASS 105 CLASS 106 CLASS 107 CLASS 120 CLASS 118 CLASS 110 CORR 102 CORR 101 CORR 114 CORR 109 CUST 113 STOR 119 TR 117 TR 115 TR 112 TR 111 VEST 108 T T T T T T T T T F F 1 RT 2 RT 3 RT 4 RT 5 RT 6 RT 7 RT 8 RT 9 RT 2 EF 1 EF F 2 EFF 2 EF F 2 EF F F T 1 N2-22 MMP TEP P.E. JOB #22133 Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 RE X B U R G , MA D I S O N S C H O O L D I S T R I C T # 3 2 1 ID A H O 890 APRIL '23 JU N I O R H I G H S C H O O L A D D I T I O N E4.0 CL A S S R O O M M E C H . C O N N E C T I O N S P L A N SCALE: CLASSROOM ADDITION - MECH. CONNECTIONS 1/8" = 1' - 0"16'8'0" N KEY NOTES 1 24/7 PROGRAMMABLE TIME CLOCK. PROGRAM AS DIRECTED BY OWNER. COMMONS 139 VEST 140 10 RT MMP TEP P.E. JOB #22133 Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 RE X B U R G , MA D I S O N S C H O O L D I S T R I C T # 3 2 1 ID A H O 890 APRIL '23 JU N I O R H I G H S C H O O L A D D I T I O N E4.1 CO M M O N S M E C H . C O N N E C T I O N S P L A N SCALE: COMMONS ADDITION - MECH. CONNECTIONS 1/8" = 1' - 0"16'8'0" N MECHANICAL EQUIPMENT SCHEDULE CIRCUITMCASYMBOL EH 1 HEATER DESCRIPTION ELECTRIC H.P.VOLTS -208 1 - Ø 2.0 N1-27 K.W.FEEDER 1/2"C., 2-#12 + GROUND REMARKS SCHEDULE NOTES: EH 2 HEATER ELECTRIC -208 1 -4.0 NOTE 5. EF 1 FAN EXHAUST -120 3 .5 -N2-24 NOTE 1. EF 2 FAN EXHAUST -120 1 -127 NOTE 2.NOTE 2. (WATT) MOCP - - - - RT 1 UNIT ROOF TOP 21.4 208 3 1 -N1-26 NOTES 1., 3.30 RT 2 UNIT ROOF TOP 208 3 1 -N2-32 RT 3 UNIT ROOF TOP 208 3 1 -N1-32 RT 4 UNIT ROOF TOP 208 3 1 -N2-38 RT 5 UNIT ROOF TOP 208 3 1 -N1-38 RT 6 UNIT ROOF TOP 208 3 1 -N2-31 RT 7 UNIT ROOF TOP 208 3 1 -N1-31 RT 8 UNIT ROOF TOP 208 3 1 -N1-37 RT 9 UNIT ROOF TOP 208 3 1 -N2-37 RT 10 UNIT ROOF TOP 79 208 3 3 -NOTE 4.1 1/4"C., 3-#2CU + GRND100 21.4 30 21.4 30 21.4 30 21.4 30 21.4 30 21.4 30 21.4 30 21.4 30 1/2"C., 3-#12 + GROUND 1/2"C., 2-#12 + GROUND 1/2"C., 2-#12 + GROUND 1/2"C., 3-#10 + GROUND 1/2"C., 3-#10 + GROUND 1/2"C., 3-#10 + GROUND 1/2"C., 3-#10 + GROUND 1/2"C., 3-#10 + GROUND 1/2"C., 3-#10 + GROUND 1/2"C., 3-#10 + GROUND 1/2"C., 3-#10 + GROUND 1/2"C., 3-#10 + GROUND NOTES 1., 3. NOTES 1., 3. NOTES 1., 3. NOTES 1., 3. NOTES 1., 3. NOTES 1., 3. NOTES 1., 3. NOTES 1., 3. NOTES 1., 3. 1.PROVIDE AND INSTALL LOCAL DISCONNECT 2.CONNECT TO LIGHTING CIRCUIT. CONTROL WITH FAN TIMER SWITCH. 3.PROVIDE AND INSTALL A 1/2" CONDUIT TO RESPECTIVE STAT. 4.CONNECT TO 100A 3P BREAKER IN EXISTING PANEL-"K1". CLASS 103 CLASS 104 CLASS 105 CLASS 106 CLASS 107 CLASS 120 CLASS 118 CLASS 110 CORR 102 CORR 101 CORR 114 CORR 109 CUST 113 STOR 119 TR 117 TR 115 TR 112 TR 111 VEST 108 MMP TEP P.E. JOB #22133 Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 RE X B U R G , MA D I S O N S C H O O L D I S T R I C T # 3 2 1 ID A H O 890 APRIL '23 JU N I O R H I G H S C H O O L A D D I T I O N E5.0 CL A S S R O O M F I R E A L A R M P L A N SCALE: CLASSROOM ADDITION - FIRE ALARM 1/8" = 1' - 0"16'8'0" N COMMONS 139 VEST 140 10 RT 1 MMP TEP P.E. JOB #22133 Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 RE X B U R G , MA D I S O N S C H O O L D I S T R I C T # 3 2 1 ID A H O 890 APRIL '23 JU N I O R H I G H S C H O O L A D D I T I O N E5.1 CO M M O N S F I R E A L A R M P L A N SCALE: COMMONS ADDITION - FIRE ALARM 1/8" = 1' - 0"16'8'0" N FIRE ALARM RISER DIAGRAM NO SCALE CONTROL PANEL FIRE ALARM (FACP) 4 #14 FS TO TELEPHONE BOARD 2 #14 D 2 #14 R ANN TS }CABINET H 2 #14 WP CONTROL 2" C., SYNC.} TYPICAL NOTIFICATION APPLIANCE CIRCUIT TYPICAL STROBE CIRCUIT TYPICAL INITIATING DEVICE CIRCUIT FIRE SPRINK SYSTEM FLOW /TAMPER SW. CKT. REMOTE ANNUNCIATOR CIRCUIT MECH. EQUIPMEMT FAN SHUT DOWN DOOR HOLDER CIRCUIT (2) CAT 6 CABLES CONDUIT (TYP) SPECIAL NOTE: MEET THE SPECIFIED DESIGN CRITERIA. DETERMINED BY THE ELECTRICAL AND FIRE ALARM CONTR'S. TO FIRE ALARM SYSTEM CONDUIT AND OR CABLE ROUTING SHALL BE* *SUBMIT SHOP DRAWINGS AND REQUIRED CALCULATIONS TO THE AUTHORITY HAVING JURISDICTION. OBTAIN A WRITTEN LETTER OF ACCEPTANCE OF THE PROPOSED SYSTEM. INCLUDE WITH SHOP DRAWINGS SUBMITTAL TO ENGINEER. LOCATED AT A COMMON HEIGHT. ALL CLASS "B" INITIATING CIRCUITS WITH ADDRESSABLE DEVICES HORN / STROBES IN A COMMON ROOM OR LINE OF SIGHT SHALL BE LOCATE AS CLOSE TO 80" AS POSSIBLE, NOT EXCEEDING 96". ALL 80". IF THIS CONFLICTS WITH OTHER TRADES OR ROOM FURNISHINGS, BETWEEN 80" TO 96" ABOVE FINISH FLOOR. THE PREFERRED HEIGHT IS NFPA ALLOWS HORN / STROBES TO BE MOUNTED AT A HEIGHT RANGE DUCT DETECTOR, ETC.. FALSE ALARM WILL OCCUR. HAS A POWER HELD CONTACTS. (FLOW , TAMPER, HOOD SYSTEM, DO NOT CONNECT THE FIRE ALARM SYSTEM TO ANY DEVICE WHICH TO MEET ADA REQUIREMENTS. MOUNT PULL STATIONS AT 46-48" A.F.F. TO THE OPERATING HANDLE QUANTITIES PER FIRE ALARM SYSTEM SUPPLIER, AND AS PER NFPA ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL CONDUCTOR NEED EOLR. (END OF LINE RESISTORS). DOWN UPON FIRE ALARM AS PER LIFE SAFETY CODES. ALL AIR HANDLING EQUIPMENT 2000 CFM OR MORE MUST BE SHUT NOT EXCEED 120 DEVICES ON ANY ONE ADDRESSABLE DEVICE RUN. DO NOT EXCEED 2500 FEET ON ANY ADDRESSABLE DEVICE RUN. DO DO NOT INSTALL ANY SMOKE OR HEAT DETECTOR WITHIN 3 FEET OF ACCORDING TO ROOM SIZE, ETC. PROVIDE THE REQUIRED CANDELA RATING OF ALL HORN / STROBES FROM ENDS OF CORRIDORS AND A MAXIMUM OF 100' SPACING. HORNS / STROBES TO BE SYNCHRONIZED TO PROVIDE A 3-3-3 LOCATION AND LAYOUT ONLY. SHOP DRAWINGS. FIRE ALARM PLAN IS SHOWN FOR GENERAL ALL WIRING AND CONDUIT ROUTING TO BE AS DESCRIBED ON SUPPLIED THE FIRE ALARM SYSTEM TO BE IN COMPLIANCE WITH ALL APPLICABLE LOCAL, STATE AND ADA REQUIREMENTS. IN CORRIDORS, HORN / STROBES MUST BE LOCATED WITHIN 15' 14. TEMPORAL PATTERN. 12. 13. 11. 10. AND NEC REQUIREMENTS. ANY AIR DIFFUSER. 7. 9. 8. 6. 5. 4. 3. 2. DO NOT INSTALL MORE THAN (10) HORN / STROBES ON ANY SINGLE FIRE ALARM SYSTEM NOTES: CLASS "B" SIGNAL CIRCUIT. DO NOT EXCEED 400 FT. OF NO. 14 WIRE IN THE TOTAL LOOP. 1. EOL EOL EOL EOL A. Provide all the equipment, materials and labor necessary to expand the existing fire alarm system. The system addition shall be connected directly to the existing main fire alarm panel. The installation shall be as recommended by the manufacturer and accepted by the local authority having jurisdiction. When the system is complete, a factory representative shall test the system, make adjustments and place the system in operating order. Existing system is Simplex. Field verify prior to bidding. B. Within twenty days after the contract award and prior to the purchase of any equipment, the fire alarm system contractor shall submit for approval six (6) copies of the following: 1. A list of materials that are to be used on the project, including manufacturer, model number and technical information. 2. Preliminary circuit diagrams showing interconnection of all modules, detectors, horns, panels and wiring counts. Diagrams are to be 11"x17" done in a good workmanlike manner. 3. Technical manuals for all of the equipment that is to be used on the project. 4. Submit shop drawings and required calculations to the local authority having jurisdiction. Obtain a written Letter of Acceptance of the proposed system. Include with shop drawings submittal to engineer. C. Contractor shall provide and install all required power supplies, electronics and connections to modify existing system to accept new addition. Complete system shall maintain UL listing. FIRE ALARM SYSTEM EXPANSION NOTES: EXISTING SIMPLEX FIRE ALARM SYMBOL SCHEDULE WALL MOUNTED HORN/STROBE (## = CANDELA RATING) WALL MOUNTED STROBE ONLY (## = CANDELA RATING) CEILING MOUNTED HORN/STROBE (## - STROBE CANDELA RATING) CEILING MOUNTED STROBE ONLY (## - STROBE CANDELA RATING) WALL MOUNTED HORN ONLY MANUAL PULL STATION PHOTOELECTRIC SMOKE DETECTOR ADDRESSABLE MONITORING MODULE TAMPER SWITCH (VERIFY EXACT NUMBER W/ FIRE SPRINKLER CONTR.) FLOW SWITCH (VERIFY EXACT NUMBER W/ FIRE SPRINKLER CONTR.) ## ## ## ## MAGNETIC DOOR HOLD-OPEN F SD FIRE/SMOKE DAMPER WALL MOUNTED FIRE ALARM BELL, MOUNT @ 10'-0" FIRE ALARM RELAY MODULE HEAT DETECTORH DETECTOR SUB- SCRIPTS D = DUCT DETECTOR ID = IN-DUCT DETECTOR M = MULTI-STATION DETECTOR (120V W/ BATTERY BACKUP) GENTEX# S1209F OR EQUAL. FIRE ALARM VOICE EVACUATION PANEL, PROVIDE CONNECTION TO FACP AS REQUIRED. MOUNT TOP @ 6'-0". FIRE ALARM ANNUCIATOR PANEL (VERIFY LOCATION WITH LOCAL AHJ PRIOR TO ROUGH-IN) PANEL SHALL BE FLUSH MOUNTED TOP @ 5'-0". FIRE ALARM CONTROL PANEL (PROVIDE (2) DEDICATED PHONE LINES) MOUNT TOP @ 6'-0". FIRE ALARM LED INDICATOR LIGHT T = REMOTE TEST STATION FOR DUCT DETECTOR CEILING MOUNTED HORN ONLY MM TS FS RM FACP VEP ANN NOTIFICATION APPLIANCE EXTENDER PANEL(S), PROVIDE NUMBER OF PANELS AS REQUIRED TO MEET CURRENT NFPA 72 VOLTAGE DROP CALCULATIONS. MOUNT TOP @ 6'-0".NAC KEY NOTES 1 PROVIDE AND INSTALL A DUCT DETECTOR AND RELAY MODULE. CONNECT TO SHUT DOWN UNIT UPON DETECTION. CLASS 103 CLASS 104 CLASS 105 CLASS 106 CLASS 107 CLASS 120 CLASS 118 CLASS 110 CORR 102 CORR 101 CORR 114 CORR 109 CUST 113 STOR 119 TR 117 TR 115 TR 112 TR 111 VEST 108 3 2 1 1 1 1 1 1 1 1 MMP TEP P.E. JOB #22133 Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 RE X B U R G , MA D I S O N S C H O O L D I S T R I C T # 3 2 1 ID A H O 890 APRIL '23 JU N I O R H I G H S C H O O L A D D I T I O N E6.0 CL A S S R O O M C A B L E T R A Y P L A N SCALE: CLASSROOM ADDITION - CABLE TRAY 1/8" = 1' - 0"16'8'0" N ENLARGED VIEW CABLE TRAY MOUNTING DETAIL (WIDTH AS SPECIFIED) A SECTION A-A CABLE TRAY CUTTING TOOL 3. ALL TURNS IN ANY DIRECTION OR PLANE SHALL BE RADIUSED. NO SHARP E.C. SHALL PROVIDE AND INSTALL ALL REQUIRED MOUNTING HARDWARE & INSTALLATION PRACTICES PER MANUFACTURER. E.C. SHALL MAINTAIN 12" MIN. ABOVE CABLE TRAY. (TYPICAL) LOCATE 5FT. ON CENTER. ANCHOR TO STRUCTURE 3/8" ALL-THREAD ROD ELECT. CONTR. SHALL PROVIDE AND INSTALL A COMPLETE STEEL WIRE MESH CABLE TRAY SYSTEM FOR ROUTING DATA AND/OR COMMUNICATIONS CABLE. SUSPEND AND SUPPORT FROM BLDG. STRUCTURE, USING 3/8" ALLTHREAD. SUPPORT AS RECOMMENDED BY MANUFACTURER. TRAY DIMENSIONS SHALL BE 12"W x 2"D. UTILIZE RADIUSED ELBOWS AND TEES. SHARP 90'S, ARE NOT ACCEPTABLE. NOTE THAT THIS TRAY SYSTEM HAS BEEN SELECTED TO FACILITATE EASE OF ROUTING UP/OVER/AROUND EXISTING OR NEW DUCTWORK, PIPING, AND OTHER EQUIPMENT. THIS INSTALLATION WILL REQUIRE FIELD MODIFICATION TO MEET SPECIFIED CLEARANCES. PROVISIONS FOR THIS TYPE OF ENVIRONMENT SHALL BE INCLUDED IN THE BASE BID. ACCEPTABLE MANUFACTURERS: EZ TRAY BY CABOLOFIL CORNERS ARE PERMISSIBLE. AND FLEX TRAY BY GS METALS. CABLE TRAY SYSTEM: STEEL HANGER CABLE TRAY B B ON THIS DWG. AND IN THE SPECIFICATIONS. ALONG WITH ALL MISC. 2. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION INCLUDING STRUCTURAL, HVAC, PIPING, FIRE SPRINK. ETC. MAKE NECESSARY 1. E.C. SHALL PROVIDE AND INSTALL ALL COMPONENTS AS DESCRIBED ADJUSTMENTS TO ACCOMMODATE THESE TRADES. COMPONENTS REQUIRED FOR A COMPLETE TRAY SYSTEM. CABLE TRAY NOTES A SECTION B-B ANGLED BLADES OFF-SET BLADES OFF-SET BOLT CUTTER 12" DATA 6" INTERCOM TRAY MANAGEMENT DETAIL NO SCALE CABLE TRAY INSTALLATION SHALL CONFORM TO NEC 392 6" KEY NOTES 1 PROVIDE AND INSTALL A 2" CONDUIT FROM CABLE TRAY TO ABOVE ACCESSIBLE CEILING SHOWN FOR DATA CABLING. INSTALL INSULATED BUSHINGS 2 3 BOTH ENDS. PROVIDE AND INSTALL (2) 4" SLEEVES THROUGH WALL. INSTALLATION AND CAULKING TO MAINTAIN FIRE RATING. (4) 4" CONDUIT THROUGH WALL TO IT ROOM.