I will be following the prescriptive insulation path for climate zone 6 for the home located at
Address
The prescriptive insulation values and u factors are shown below.
Table R402.1.2
Insulation and Fenestration Requirements by Components
Climate Fenestration Skylight Ceiling R- Wood Floor R- Basement Slab R Crawlspace
Frame Value Wall R Value tValue
Zone U-Factor U-Factor Value
Wall R- Value &
Value Depth
6 30 55 49* 22 or 30 15/19* I 10, 4 ft I 15/19*
13+5*
*Notes
13-5, The first value is cavity and the second value is continuous. Therefore "13+5"means R13 cavity plus RS continuous insulation.
15119, The first value is continuous insulation and the second value is cavity insulation
R30 ceiling insulation may be used under certain conditions as per N1102.2.2