Loading...
HomeMy WebLinkAboutPLANS - 23-00681 - 3766 Wagon Trail Rd- RV pad - Plumbing65123 B C 4 A D 651234 B C A D STAMP JOB N0.: CHECKED BY: SHEET NO. DRAWN BY: DATE: C A L L E N G I N E E R I N G , P A St r u c t u r a l E n g i n e e r s 29 3 9 N o r t h C o l e R d , S u i t e 1 0 2 B o i s e , I D 8 3 7 0 4 MO Y L E -BO Y D SP O R T S C O U R T & G A R A G E GE N E R A L S T R U C T U R A L N O T E S S1.0 23113 AMC SMC 07-07-2023 37 6 6 W a g o n T r a i l R d R e x b u r g , I d a h o GENERAL STRUCTURAL NOTES (GSN): AB ANCHOR BOLT ADJ ADJACENT AFF ABOVE FINISHED FLOOR ARCH ARCHITECTURAL BLKG BLOCKING BM BEAM BRG BEARING BTWN BETWEEN CL CENTER LINE CJ CONTROL JOINT CLG CEILING CLR CLEARANCE CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONN CONNECTION CONT CONTINUOUS COORD COORDINATE DBL DOUBLE DET DETAIL DRWG DRAWING EF EACH FACE ELEV ELEVATION EW EACH WAY EXT EXTERIOR FF FINISHED FLOOR FIN FINISHED FLR FLOOR FND FOUNDATION FO FACE OF FOC FACE OF CONCRETE FOS FACE OF STUD FRMG FRAMING FTG FOOTING GA GAGE GLB GLULAM BEAM GYP GYPSUM GSN GENERAL STRUCTURAL NOTES HCA HEADED CONCRETE ANCHOR HT HEIGHT HD HOLDOWN HSB HIGH STRENGTH BOLT INT INTERIOR LL LIVE LOAD LLV LONG LEG VERTICAL LOC LOCATION LSL LAMINATED STRAND LUMBER LVL LAMINATED VENEER LUMBER MECH MECHANICAL MEZZ MEZZANINE MIP METAL INSULATED PANEL NTS NOT TO SCALE OC ON CENTER OPNG OPENING OSB ORIENTED STRAND BOARD PL PLATE PAF POWDER ACTUATED FASTENER PLF POUNDS PER LINEAR FOOT PSI POUNDS PER SQUARE INCH PSF POUNDS PER SQUARE FOOT PSB PARALLEL STRAND BOARD PT PRESSURE TREATED REINF REINFORCEMENT REQD REQUIRED SCHED SCHEDULE SHT SHEET SIM SIMILAR STD STANDARD STL STEEL TO TOP OF TOB TOP OF BEAM TOF TOP OF FOOTING TOJ TOP OF JOIST TOM TOP OF MASONRY TOS TOP OF STEEL TYP TYPICAL UNO UNLESS NOTED OTHERWISE WWF WELDED WIRE FABRIC WTS WELDED-THREADED STUD ABBREVIATIONS IBC TABLE 2304.10.1 ABBREVIATED FASTENING SCHEDULE DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER SPACING AND LOCATION Blocking between ceiling joists, rafters or trusses to top plate or other framing below 3 -3"x0.131" nails Each end, toenail Blocking between rafters or trusses not at the wall top plate, to rafter or truss 2 -3"x0.131" nails Each end, toenail 3 -3"x0.131" nails End nail Ceiling joists to top plate 3 -3"x0.131" nails Each joist, toenail Rafter or roof truss to top plate 4 -3"x0.131" nails Toenail Stud to stud (not at braced wall panels)3"x0.131" nails 16" o.c. face nail Stud to stud and abutting studs at intersecting wall corners (at braced wall panels)3"x0.131" nails 12" o.c. face nail Sill to Trim Stud 3 -3"x0.131" nails Endnail Top plate to top plate 3"x0.131" nails 12" o.c. face nail Top plate to top plate, at end joints 12 -3"x0.131" nails Each side of end joint, face nail (minimum 48" lap splice length each side of end joint) Bottom plate to joist, rim joist, band joist or blocking (not at braced wall panels)3"x0.131" nails 12" o.c. face nail Bottom plate to joist, rim joist, band joist or blocking at braced wall panels 4 -3"x0.131" nails 16" o.c. face nail Stud to top or bottom plate 3 -3"x0.131" nails End nail 4 -3"x0.131" nails Toenail Top or bottom plate to stud 3 -3"x0.131" nails End nail Top plates, laps at corners and intersections 3 -3"x0.131" nails Face nail Joist to sill, top plate, or girder 3 -3"x0.131" nails Toenail Rim joist, band joist, or blocking to top plate, sill or other framing below 3"x0.131" nails 6" o.c., toenail Built-up girders and beams, 2" lumber layers 3"x0.131" nails 24" o.c. face nail at top and bottom staggered on opposite sides Joist to band joist or rim joist 4 -3"x0.131" nails End nail Bridging or blocking to joist, rafter or truss 2 -3"x0.131" nails Each end, toenail Note: Nailing shall be according to this table unless noted otherwise. DESIGN CRITERIA: 1. Building code used for design 2018 International Building Code 2. Risk Category II 3. Design Dead Loads: Roof dead load 17 psf 4. Roof Live Loads:20 psf 5. Roof Snow Loads: Ground Snow Load Pg = 50 psf Snow Importance Factor Is = 1.0 Snow Exposure Coefficient Ce = 1.0 Thermal Exposure Coefficient Ct = 1.0 Roof Snow Load Pf = 35 psf Drift Surcharge Loads Drift loads have been included in truss loading diagrams 6. Seismic Loads: Seismic Importance Factor Ie = 1.0 Soil Site Class D Mapped Spectral Acceleration SS = 0.349 S1 = 0.138 5% Damped Design Spectral SDS = 0.354 SD1 = 0.214 Response Acceleration Seismic Design Category D Seismic Main Force Resisting System Light-frame (wood) walls sheathed with wood structural panels rated for shear resistance Response Modification Coefficient R = 6.5 Over-strength Factor Ωo = 3.0 Deflection Amplification Factor Cd = 4.0 Seismic Response Coefficient Cs = 0.054 (LRFD -Strength Design) Cs asd = 0.038 (ASD -Allowable Stress Design) Effective Seismic Weight W =Dead load of the structure plus 20% of the uniform design snow load Design Base Shear V = 0.054 x W (LRFD -Strength Design) VASD = 0.038 x W (ASD -Allowable Stress Design) Analysis Procedure Equivalent lateral force 7. Wind Loads: Design Wind speed (3-second gust)Vult = 105 mph per ASCE/SEI 7-16 Exposure Classification C Internal Pressure Coefficient GCpi = ± 0.18 Topographic Factor Kzt = 1.0 FOUNDATIONS: 1. Allowable Foundation Soil Bearing Pressure 1500 psf (default value) 2. Allowable Soil Bearing Increase 1/3 increase for short-term loading (wind & seismic loads) 3. Frost Depth 36”minimum from lowest point of finished adjacent grade to bottom of footing 4. Footings to bear on undisturbed native soil or engineered fill compacted to 95% density (ASTMD1557) 5. Where excavations occur under footings, after the building footings have been cast, said excavations shall be filled with flowable fill. CONCRETE: 1. Concrete mix design shall be established in accordance with Chapter 19 of ACI 318-14. 2. Minimum cement content 500 lbs/yd3 for 3500 psi concrete 564 lbs/yd3 for 4000 psi concrete 3. Maximum water/cement ratio 0.50 4. Entrained air 5% (±11/2%) for all concrete exposed to freezing 5. Maximum slump 4" 6. 28-day compressive strength f'c = 3500 psi at footings and stem walls f'c = 4000 psi at interior slabs 7. Minimum concrete cover over reinforcement for cast-in-place concrete: Concrete cast against and permanently exposed to earth……………3" Concrete exposed to earth or weather: #5 and smaller bars……………………………………………1 1/2" * Concrete not exposed to weather or in contact with ground: #11 and smaller bars……………………………………………3/4" * * Above noted cover dimensions are code minimums. Where possible, use 2”cover unless noted otherwise. 8. Reinforcing Steel a. ASTM 615 grade 60 (Fy = 60 ksi) b. Provide minimum rebar lap of 40 bar diameters. c. Provide corner bars at all wall and footing corners and intersections. d. All reinforcing steel shall be in place and properly positioned prior to placing concrete. 9. Flowable fill shall be Controlled Low Strength Material (CLSM) per ACI 229R. Required strength shall be 100 to 600 psi. POST-INSTALLED ANCHORS: 1. Adhesive Anchors a. In concrete, adhesive shall be Simpson Strong-Tie SET-3G or approved equivalent. b. Follow manufacturer’s instructions for the installation of adhesive post-installed anchors. 2. Screw Anchors a. In concrete screw anchors shall be Simpson Strong-Tie Titen HD. b. Follow manufacturer’s instructions for the installation of screw anchors. LUMBER: 1. Material: a. Sawn lumber 2x4 Douglas Fir Larch Construction grade b. Sawn lumber 2x6 or larger Doug Fir Larch No. 2 or higher grade 2. Preservative-treated wood: a. Preservative-treated wood shall be Douglas Fir Larch. b. Preservative-treated wood shall be treated with SBX/DOT or Zinc Borate. Fasteners, including nuts and washers, into preservative-treated wood shall be of hot dipped zinc-coated galvanized steel in accordance with ASTM A153 (ASTM A 653, type G185 or better). See IBC 2304.10.5. c. Wood framing members that rest on exterior foundation walls and are less than 8" from exposed earth shall be preservative-treated wood (per IBC 2304.12.1.2). 3. Sheathing: a. Wood Roof Sheathing • Thickness:7/16” • APA Span Rating:24/16 (minimum) • Panel edge nailing:6”oc • Field nailing:12”oc • Orient roof sheathing with 8’-0”length perpendicular to supporting members. • Use of ‘H’clips to provide correct panel spacing is acceptable but not required. • Nail roof sheathing to blocking at 6”oc • Minimum sheathing panel dimension shall be 24”unless all panel edges of the undersized sheets are supported by and fastened to framing members or blocking. • Block all panel edges at roof sheathing where indicated on plans. • Nail wood roof sheathing to supporting members with 0.131”Ø x 2 1/2”nails b.Wood Wall Sheathing • Thickness: 7/16” • APA Span Rating:24/16 (minimum) • Orient wall sheathing with 8’-0”length perpendicular to supporting members. • Use of ‘H’clips to provide correct panel spacing is acceptable but not required. • Block all panel edges of wall sheathing • Panel edge nailing:6”oc • Field nailing:12”oc • Minimum sheathing panel dimension shall be 24”unless all panel edges of the undersized sheets are supported by and fastened to framing members or blocking. • Nail wood wall sheathing to supporting members with 0.131”Ø x 2 1/2”nails c.Gypsum Sheathing at ceiling of garage area • Thickness:5/8” • Fasteners:6d cooler (0.092”x 1 7/8”long, 1/4" head) • Edge nailing:7”oc • Field nailing:12”oc d.Do not install edge nailing beneath straps prior to installing straps over sheathing. 4.Fasteners: a. Nailing to follow IBC table 2304.10.1 on sheet S1.0unless noted otherwise. b. All framing nails are to be 0.131”Ø x 3”unless noted otherwise. c. Nails shall meet requirements in ASTM F1667. • Provide ICC ES Report. • ICC ES report number and country of origin shall be labeled on nail containers. • Provide nails with head identification. d.Where nailed connections of 2x material are not shown, provide (2) nails or (3) toe-nails minimum at each connection. e.For connections of "Simpson" hardware or equivalent, nail per manufacturer's requirements. 5.Pre-Manufactured Trusses: a. Truss manufacturer shall provide proof of approved third-party inspection as required by IBC. b. Truss fabricator shall contact Call Engineering for a teleconferenced pre-designed meeting prior to submitting truss shop drawings. c. Provide shop drawings including the following in addition to the requirements of IBC 2303.4: • Truss placement plan • Locations for truss-to-truss connections d.Truss loading, individual truss drawings and calculations to be stamped by Professional Engineer registered in the State of Idaho. e.Truss plates shall extend 2" minimum onto each member involved in a joint. f.Design trusses for uniform and unbalanced snow loads according to ASCE7-16 section 7.6 g.Design trusses for 10 psf uniform top chord dead load and 7 psf uniform bottom dead load. h.Design trusses for wind loads per ASCE7-16, components & cladding. Dead load for use with wind load cases is 9 psf. i.Design trusses for a 380 lb point load occurring at any location along the bottom chord non-concurrent with snow load. j.Truss design to allow for a 1/4" wood screw to be installed at any location in the truss bottom chord. k.Maximum truss panel lengths to be 10-feet at top chord & bottom chord. l.Each chord member shall cross at least (2) panel joints before being spliced. m.Provide 2x T-brace per detail 6/S4.0 at each web member where web bracing is indicated on truss manufacturers' drawings. Alternate braced details including continuous lateral bracing and associated restraints may be submitted for approval by structural engineer. n.Truss design to be submitted to Building Department as a deferral submittal if required. o.Truss repairs shall be stamped by a Professional Engineer and submitted to Call Engineering for review prior to repairing any truss. 6."H-clips" at roof sheathing are not required but may be used at contractor's option for proper sheathing installation. MISCELLANEOUS 1. Submit all required shop drawings and receive their satisfactory review from the Structural Engineer prior to fabrication. 2. Provide temporary erection bracing and shoring as required for stability of structure during all phases of construction. 3. Additional requirements to meet OSHA or other construction criteria which may exceed requirements indicated in construction documents are the responsibility of the contractor. 4. Verify all dimensions and existing conditions prior to starting work and notify Structural Engineer immediately of any discrepancies. 5. Details are typical and apply at similar conditions throughout. 6. In the case of disagreement between General Structural Notes and sheet notes or details, the more stringent requirement shall apply. GENERAL STRUCTURAL NOTES CONT'D: MR K D A T E D E S C R I P T I O N H D U 4 H D U 4 H D U 4 H D U 4 H D U 4 H D U 4HDU4HDU4H D U 4 H D U 4 H D U 4 H D U 4 H D U 4 SLAB CAST OVER STEM WALL WHERE INDICATED BY: SEE 2/S3.0 TYP 1 GIRDER TRUSS T-2. SEE TRUSS PROFILES AND LOADING DIAGRAMS 4 T-1 TRUSSES @ 16" OC. SEE TRUSS PROFILES AND LOADING DIAGRAMS 5 2x8 @ 16" OC6 MONOSLOPE T-3 TRUSSES @ 16" OC. SEE TRUSS PROFILES AND LOADING DIAGRAMS 7 BASKETBALL HOOP. ATTACH DIRECTLY TO STUD WALL w/ (3) SIMPSON SDS 1/4x3" SCREWS EACH BRACKET 8 HIP JACK TRUSS9 JACK TRUSSES @ 24" OC10 STEP-DOWN TRUSSES @ 24" OC11 TRUSSES @ 24" OC. DESIGN ALL TRUSSES AT UPPER ROOF FOR 17 PSF DEAD LOAD AND 35 PSF SNOW LOAD w/ DRIFTING & UNBALANCED SNOW LOAD PER ASCE7-16 REQUIREMENTS 12 A. REVIEW CRACK CONTROL WITH CONCRETE SUBCONTRACTOR B. SEE SHEET S3.0 FOR HEADER SCHEDULE & TYPICAL WALL FRAMING & HOLDOWN DETAILS C. HOLDOWNS SHOWN ARE LOCATED AT JAMBS OF WALL OPENINGS, WALL CORNERS OR AT END OF WALL PIERS UNLESS NOTED OTHERWISE D. NOTES KEYNOTES GABLE END TRUSS13 2-PLY GIRDER TRUSS14 MUD SILL ANCHOR. SEE 3/S3.02 DBL STUD @ GIRDER TRUSS3 IF TRUSSES DO NOT ALIGN w/ STUDS IN WALL BELOW PROVIDE TRIPLE TOP PLATE @ TOP OF WALL 15 INDICATES JAMB w/ (1) TRIM STUD FULL HT TO BOTTOM OF HEADER & (1) KING STUD FULL HEIGHT TO TOP OF WALL. PROVIDE (1) TRIM & (2) KING STUDS TYP @ JAMBS UNLESS OTHERWISE NOTED 1 T 1 K 9' - 6 " 12 ' - 6 " 18 ' - 0 " 7' - 0" 13' - 0"29' - 6"17' - 6" 6' - 8 " 13 ' - 9 " ± 40 ' - 0 " 60' - 0" 2' - 0 " 12 ' - 0 " 4' - 0 " 4' - 0 " 3' - 0 " 5' - 6 " 2' - 0" 3' - 0" 2' - 0" 2' - 0 " 3' - 0 " 13' - 6"3' - 0"13' - 0" 1'-4"x9" FTG, TYP 4" CONC SLAB ON GRADE. ADD CONTROL JOINTS PER CONCRETE INSTALLER'S RECOMMENDATIONS 2' - 0 " 3' - 0 " 1 1 2 2'-0"x9" FTG 2'-0"x9" FTG 2 1 S3.0 _____ 1 S3.0 _____ 1 S3.0 _____ 4 S3.0 _____ 3 S3.0 _____ 2 S3.0 _____ 1 S3.0 _____5 S3.0 _____ TYP 8' - 0 " 21' - 6"6' - 6"32' - 0" 3' - 6" 5' - 6 " 3' - 6 " 6' - 3 " 6' - 3 " H1 H1 H1 H2 H1 H1 H3 7' - 0 " H4 H1 3' - 6 " 4 5 6 7 8 8 RI D G E 2x8 STUDS @ 24" OC, TYP 2x8 STUDS @ 16" OC 2x8 STUDS @ 16" OC 3 1 T 3 K 1 T 1 K 1 T 1 K 0 T 1 K 0 T 1 K 1 T 1 K 2 T 2 K 2 T 2 K 1 T 3 K 0 T 1 K 0 T 1 K 4 S4.0 _____ 12 S4.0 _____ 9 S4.0 _____ 3 15 15 1 T 1 K 1 S4.0 _____ SIM 9 S4.0 _____ 7 S4.0 _____ 6' - 0"6' - 0" 5' - 0 " 5' - 0 " 6' - 0"24' - 0"24' - 0"6' - 0" 5' - 0 " 15 ' - 0 " 1' - 6 " 1' - 6" 1' - 0" 1' - 6 " RIDGE H2 H2 H2 H2 H2H3 H3 H2 H2 14 9 9 10 11 12 13 H2 5' - 0 " 1 S4.0 _____ 1 S4.0 _____ 2 S4.0 _____ 3 S4.0 _____ 8 S4.0 _____ 2 S4.0 _____ 11 S4.0 _____ 1 S4.0 _____ 12 4 12 4 TRUSS T1 PROFILE LOADING 23 PLF DL 122 PLF SNOW 23 PLF DL 195 PLF SNOW 12 4 12 4 GIRDER TRUSS T2 PROFILE LOADING 77 PLF DL 470 PLF SNOW 23 PLF DL 195 PLF SNOW 12 4 TRUSS T3 PROFILE LOADING 23 PLF DL 74 PLF SNOW 23 PLF DL 161 PLF SNOW NOTE: TRUSS PROFILES ARE FOR GENERAL REFERENCE ONLY. 65123 B C 4 A D 651234 B C A D STAMP JOB N0.: CHECKED BY: SHEET NO. DRAWN BY: DATE: C A L L E N G I N E E R I N G , P A St r u c t u r a l E n g i n e e r s 29 3 9 N o r t h C o l e R d , S u i t e 1 0 2 B o i s e , I D 8 3 7 0 4 MO Y L E -BO Y D SP O R T S C O U R T & G A R A G E FO U N D A T I O N & F R A M I N G P L A N S S2.0 23113 AMC SMC 07-07-2023 37 6 6 W a g o n T r a i l R d R e x b u r g , I d a h o SCALE:1/8" = 1'-0" FOUNDATION PLAN SCALE:1/8" = 1'-0" LOWER ROOF FRAMING PLAN SCALE:1/8" = 1'-0" ROOF FRAMING PLAN SCALE:1/8" = 1'-0" LOW ROOF TRUSS PROFILES & LOADING DIAGRAMS MR K D A T E D E S C R I P T I O N A A A A TYPICAL EXTERIOR FOUNDATION1 SLAB CASTOVER AT DOORS2 JAMB TO STEM WALL AT OH DOOR3 FTG & STEM WALL TO EXIST.4 HOLDOWN5 PER PLAN EQ EQ 3' - 0 " 9" M I N 3' - 0 " M I N FR O S T D E P T H PER PLAN 2' - 4 " 30" LAP 11 11 9" M I N 8 " SCALE: 3/4" = 1'-0"SCALE: 3/4" = 1'-0" 8" 3" C L R 3" C L R PER PLAN EQ EQ 3' - 0 " 9" M I N 3' - 0 " M I N FR O S T D E P T H SCALE: 3/4" = 1'-0" 8" 3" C L R SCALE: 3/4" = 1'-0" 6" 6" SCALE: 3/4" = 1'-0" 1. 2x8 @ 24" OC (16" OC @ SIM) 2. WALL SHEATHING PER GSN 3. CONCRETE SLAB ON GRADE 4. 8" CONCRETE STEM WALL 5. FOUNDATION INSULATION 6. #5 HORIZ TOP & BOT 7. #5xL @ 48" OC 8. CONC FOOTING w/ (2) #5 9. 5/8"x10" ANCHOR BOLTS @ 48" OC 2 1 3 4 5 6 7 8 3 4 5 6 7 1 2 3 7 9 6 10 1. DOOR OPENING 2. EXTERIOR CONCRETE/ASPHALT AS OCCURS 3. CONCRETE SLAB ON GRADE. THICKEN TO TOP OF STEM WALL AT CASTOVER 4. 8" CONCRETE STEM WALL 5. FOUNDATION INSULATION 6. #5 HORIZ TOP & BOT 7. #5xL @ 48" OC 8. CONCRETE FOOTING w/ (2) #5 9. VERTS IN ADJACENT STEM WALL 10. REINF IN TOP OF ADJACENT STEM WALL. DO NOT EXTEND INTO SLAB CASTOVER 11. PROVIDE (2) LAYERS OF BUILDING PAPER BTWN STEM WALL & SLAB 8 9 1. JAMB AT OVERHEAD DOOR 2. WALL SHEATHING PER GSN 3. CONCRETE SLAB ON GRADE 4. 8" CONCRETE STEM WALL 5. FOUNDATION INSULATION 6. #5 HORIZ TOP & BOT 7. #5xL @ 48" OC 8. CONC FOOTING w/ (2) #5 9. SIMPSON MASAP MUDSILL ANCHOR @ JAMB. ONE LEG UP INSTALLATION 10. (3) KING STUDS 11. (1) TRIM STUD 12. (2) ROWS SIMPSON SDS 1/4x4.5" SCREWS @ 8" OC EA SIDE OF JAMB. STAGGER 2 1 3 4 5 9 7 8 6 10 11 9 1. EXIST STEM WALL & FTG 2. (3) #5x12" DOWELS TO EXIST. STEM WALL. EPOXY EMBED 3" 3. STEM WALL & FTG PER 1/S3.0 4. (2) #5x12" DOWELS @ MID DEPTH OF EXISTING FTG. EPOXY EMBED 5" 1 3 2 34 1. (2) FULL HEIGHT STUDS MIN @ HOLDOWN 2. SIMPSON HDU4 HOLDOWN 3. 5/8"x18" THREADED ROD w/ DBL NUT @ BOT. 5" PROJECTION 4. 8" STEM WALL. REINFORCE PER DETAIL 1/S3.0 5. ADD #5xL @ HOLDOWN NOTES: A. NAIL SHEATHING @ 6" OC TO EACH STUD @ HOLDOWN B. HOLDOWN ANCHOR BOLTS ARE IN ADDITION TO TYP ANCHOR BOLTS C. COORDINATE HOLDOWN LOCATIONS WITH DOOR/WINDOW JAMB STUDS. STUD CONFIGURATION VARIES. SEE FRAMING PLANS & DETAILS FOR JAMB STUD CALLOUTS D. CENTER ANCHOR BOLT IN STEM WALL 2 1 3 4 5 12 12 SECTION A-A ELEVATION SECTION A-A HEADER CONSTRUCTIONA SHEATHING PANEL AT TOPDSHEATHING PANEL AT BLOCKINGC SHEATHING PANEL AT SILL PLATEE SPACING FASTENER PANEL SP A C I N G FA S T E N E R P A N E L SP A C I N G FA S T E N E R P A N E L SPACING FASTENER PANEL SP A C I N G FA S T E N E R P A N E L SPACING FASTENER PANEL DOUBLE TOP PLATE (TRIPLE TOP PLATE WHERE INDICATED) SHEATHING PANEL JOINT SHEATHING PANEL JOINT BLOCKING AT HORIZONTAL JOINT SHEATHING PANEL JOINT 1/ 2 " 1. HEADER MEMBERS. SEE SCHEDULE. 2. 2x8 FLAT TOP & BOT. NAIL TO HEADER MEMBERS @ 6" OC 3. EXTERIOR WALL SHEATHING 4. GYP BOARD 5. INSULATION INFILL 2 2 SCALE: 3" = 1'-0"SCALE: 3" = 1'-0"SCALE: 3" = 1'-0" SCALE: 1 1/2" = 1'-0" HEADER TO JAMBBSCALE: 1 1/2" = 1'-0" 4-PLY HEADER 4 1/8" GAP BETWEEN SHEATHING & TOP OF CONC STEM WALL 3 1 5 2 2 3-PLY HEADER 43 1 5 1. (3) NAILS TO 2x8 FLAT 2. (3) NAILS TO EA HEADER MEMBER 3. ATTACH JAMB STUDS w/ (2) ROWS OF NAILS @ 6" OC. SEE 3/S3.0 FOR JAMB STUD ATTACHMENT AT RV DOOR 4. NAIL @ 12" OC TO EACH PLY OF HEADER 3 1 2 1 NOTE: ATTACH SILL PLATE TO TRIM STUD w/ (3) NAILS 4 65123 B C 4 A D 651234 B C A D STAMP JOB N0.: CHECKED BY: SHEET NO. DRAWN BY: DATE: C A L L E N G I N E E R I N G , P A St r u c t u r a l E n g i n e e r s 29 3 9 N o r t h C o l e R d , S u i t e 1 0 2 B o i s e , I D 8 3 7 0 4 MO Y L E -BO Y D SP O R T S C O U R T & G A R A G E FO U N D A T I O N & T Y P W A L L D E T A I L S S3.0 23113 AMC SMC 07-07-2023 37 6 6 W a g o n T r a i l R d R e x b u r g , I d a h o NAIL HEADER TOGETHER w/ (2) ROWS OF NAILS @ 12" OC. EA PLY. NAIL EA PLY TO KING STUD w/ (3) NAILS. STAGGER. 1. PROVIDE 2x8 FLAT TOP & BOTTOM OF HEADER. ATTACH TO KING STUD w/ (4) NAILS. WHERE HEADER OCCURS DIRECTLY BELOW WALL DOUBLE TOP PLATE, DELETE 2x8 FLAT @ TOP OF HEADER & ATTACH DIRECTLY TO DOUBLE TOP PLATE 2. ATTACH HEADER TO TRIM STUD w/ SIMPSON LSTA18 STRAP UNO 3. NOTES: HEADER SCHEDULE MARK SIZE NOTES H1 (3) 2x6 1, 2 H2 (3) 2x10 1, 2, 3 H3 (4) 2x10 1, 2, 3 H4 (4) 2x12 1, 2, 3 MR K D A T E D E S C R I P T I O N 2 6 8 3 4 1 7 7 5 1 3 2 4 5 4 5 2 WALL PERPENDICULAR TO TRUSSES WALL PARALLEL TO TRUSSES 6 " 3 " A A 3/4" GAP 3/4" GAP 2 6 8 3 4 1 7 7 5 1 3 2 4 5 4 5 2 WALL PERPENDICULAR TO TRUSSES WALL PARALLEL TO TRUSSES SCALE: 3/4" = 1'-0"SCALE: 3/4" = 1'-0" SCALE: 3/4" = 1'-0" SCALE: 3/4" = 1'-0" SCALE: 3/4" = 1'-0"SCALE: 3/4" = 1'-0"SCALE: 3/4" = 1'-0" SCALE: 3/4" = 1'-0" SCALE: 3/4" = 1'-0"SCALE: 3/4" = 1'-0"SCALE: 3/4" = 1'-0"SCALE: 3/4" = 1'-0" 2 6 8 3 4 1 7 7 5 1 3 2 4 5 4 5 2 WALL PERPENDICULAR TO TRUSSES WALL PARALLEL TO TRUSSES 2 6 8 3 4 1 7 7 5 1 3 2 4 5 4 5 2 WALL PERPENDICULAR TO TRUSSES WALL PARALLEL TO TRUSSES 6 " 3 " A A 3/4" GAP 3/4" GAP STEPPED HIP2 RIDGE3 TRUSS WEB 'T'-BRACE6 TYPICAL EAVE AT WOOD WALL1 NEW FRAMING TO EXISTING WALL7NON-STRUCT WALLS TO TRUSSES5 END WALL8 MONO TRUSS TO BEAM4 EAVE AT LOW ROOF9 HIP RIDGE10 FRAMING AT HEADER11 BEAM TO STUD WALL12 2 6 8 3 4 1 7 7 5 1 3 2 4 5 4 5 2 3" 2 " 3" 3" 1 1 / 2 " 1 1 / 2 " 1'-0" MAX 20'-0" T.O. PLATE 1'-6" 10 3 / 4 " T.O. BEAM 1'-6" 10 3 / 4 " 3" 3" 10'-0" T.O. PLATE SEE ARCH 10 3 / 4 " 2 " 10'-0" T.O.BEAM 20'-0" T.O. PLATE WALL PERPENDICULAR TO TRUSSES WALL PARALLEL TO TRUSSES 1. GIRDER TRUSS 2. ROOF SHEATHING PER GSN 3. JACK TRUSS AT 24" OC 4. TRUSS TO TRUSS CONN BY TRUSS MANUFACTURER 5. SIMPSON H3 AT EACH TRUSS 6. 2x4 FLAT 7. SIMPSON LTS20. SEE NOTE BELOW 8. ROOF TRUSS PER PLAN NOTE: NAIL STRAP TO JACK TRUSS TOP CHORD AND WRAP AROUND GIRDER TOP CHORD AS SHOWN. SPACING PER TRUSS MANUFACTURER'S SHOP DRAWINGS. USE 0.148"Øx1 1/2" NAILS TO TRUSS TOP CHORD 1. ROOF TRUSS PER PLAN 2. ROOF SHEATHING PER GSN 3. (2) NAILS TO EACH TRUSS AT EDGE OF PANEL 1 2 3 2 1. ROOF SHEATHING PER GSN 2. TRUSS WEB w/BRACE INDICATED ON TRUSS SHOP DRAWINGS 3. ROOF TRUSS 4. NAIL AT 12" OC 5. 2x T-BRACE. SEE NOTE BELOW NOTE: USE 2x4 T-BRACE FOR WEB MEMBER TO 6'. USE 2x6 T-BRACE FOR WEB MEMBERS 6' TO 10'. 1. 2x8 @ 24" OC W OOD STUD WALL 2. SPLICE EACH TOP PLATE w/ STANDARD LAP SPLICE PER NAILING SCHEDULE 3. WALL SHEATHING PER GSN 4. WOOD ROOF GABLE TRUSS w/ ENERGY HEEL 5. ROOF SHEATHING PER GSN 6. 2x FULL DEPTH BLKG w/SHAPED TOP. CLIP CORNERS FOR VENTILATION AS SHOWN IN INSET. DIMENSION SHOWN IS MEASURED ON LOW FACE FROM SHAPED TOP 7. NAIL AT 6" OC 8. FASCIA BOARD 9. (3) TOE-NAILS EACH BLKG TO TOP PLATE 10. SIMPSON H10A AT EACH TRUSS. USE H10A-2 AT DBL TRUSS 11. (3) NAILS 2x NAILER TO TOP PLATE 12. 2x NAILER BTWN TRUSSES 13. GYPSUM CEILING 14. GYPSUM SCREW AT 7" OC 6 1. EXIST STUD WALL 2. GIRDER TRUSS w/ 2x8 TOP CHORD 3. 2x10 w/ (3) ROWS SIMPSON SDS 1/4x3.5" SCREW @ EA STUD 4. SIMPSON LU28 TYP 5. 2x8 @ 16" OC NOTE: AT EXISTING STUD WALL, REMOVE EXIST EXT FINISH DOWN TO WOOD SHEATHING 1 2 3 4 5 NOTES: A. WALLS w/ INTERSECTING WALLS LESS THAN 10'-0" APART DO NOT REQUIRE THIS ATTACHMENT B. AS AN ALTERNATIVE TO HTC4, USE SIMPSON SDPW14500 DEFLECTOR SCREW @ 42" OC 1. 2x4 BLKG AT CLIP 2. SIMPSON HTC4 AT 10'-0" OC MAX ALONG WALL 3. ROOF TRUSS PER PLAN 4. INTERIOR NON-BEARING WALL w/DBL TOP PLATE 1 2 33 4 2 3 3 4 1 2 3 4 6 7 8 14 11 7 12 16 14 20 18 7 19 20 21 4 NOTES: A. IF 'T' BRACE ABUTS 4x4 BLOCKING, ATTACH 'T' BRACE TO SIDE OF 4x4 w/ (2) SIMPSON SDS 1/4x3" SCREWS & ATTACH 'T' BRACE TO WALL PLATE w/ SIMPSON A34. B. ATTACH 2x4 RUNNER TO 4x4 BLKG w/ (6) EVENLY SPACED NAILS. ATTACH TO EACH 2x4 w/ (3) NAILS. 15 17 3 13 9 10 1. 2x8 @ 24" OC W OOD STUD WALL 2. SPLICE EA TOP PLATE w/STD LAP SPLICE PER NAILING SCHEDULE 3. WALL SHEATHING PER GSN 4. GABLE END TRUSS w/VERTS AT 16" OC 5. TYPICAL ROOF TRUSS 6. ROOF SHEATHING PER GSN 7. NAIL AT 6" OC 8. FASCIA BOARD 9. 2x SOFFIT FRAMING AT 24" OC 10. (2) #9x1 1/2" SCREWS AT EACH SOFFIT 2x 11. 2x4 'T' BRACE AT EACH GABLE TRUSS VERT OVER 4' TALL 12. NAIL 'T' BRACE TO WALL TOP PLATE w/(3) TOE-NAILS. (2) NEAR SIDE (1) FAR SIDE 13. NAIL GABLE TOP CHORD TO EACH 'T' BRACE w/(2) NAILS 14. NAIL EACH GABLE END TRUSS VERT TO 'T' BRACE AT 12" OC 15. 2x4 x 16' LONG FLAT RUNNER AT 4'-0" OC ±. SHIFT TO AVOID TRUSS WEBS IF NECESSARY. ATTACH TO BLKG PER NOTE B 16. 4x4 BLKG AT FIRST TRUSS BAY. ALIGN w/2x4 FLAT RUNNER 17. 2x4 BLKG AT 2x4 RUNNER AT TYPICAL TRUSS BAY 18. SIMPSON A34 ONE FACE 4x4 BLKG TO TOP PLATE 19. 2x6 NAILER. NAIL TO TOP PLATE AT 8" OC STAGGERED 20. GYPSUM CEILING. ATTACH TO 2x4 & 4x4 BLKG w/SCREWS AT 7" OC 21. GYPSUM SCREW AT 7" OC 5 10 2 9 13 7 5 4 6 8 13 97 6 14 12 11 1. 4x8 BEAM 2. SIMPSON H2.5T 3. (3) TOENAILS PER BLOCK 4. WOOD TRUSS 5. ROOF SHEATHING 3 5 1 2 4 1. 2x8 @ 24" OC W OOD STUD WALL 2. TRIPLE TOP PLATE. SPLICE EACH TOP PLATE w/ STANDARD LAP SPLICE PER NAILING SCHEDULE 3. WALL SHEATHING PER GSN 4. WOOD ROOF GABLE TRUSS w/ ENERGY HEEL 5. ROOF SHEATHING PER GSN 6. 2x FULL DEPTH BLKG w/SHAPED TOP. CLIP CORNERS FOR VENTILATION AS SHOWN IN INSET. DIMENSION SHOWN IS MEASURED ON LOW FACE FROM SHAPED TOP 7. NAIL AT 6" OC 8. FASCIA BOARD 9. (3) TOE-NAILS EACH BLKG TO TOP PLATE 10. SIMPSON H10A AT EACH TRUSS. USE H10A-2 AT DBL TRUSS 11. (3) NAILS 2x NAILER TO TOP PLATE 12. 2x NAILER BTWN TRUSSES 13. GYPSUM CEILING 14. GYPSUM SCREW AT 7" OC 6 10 2 9 13 7 5 4 6 8 13 97 6 14 12 11 1. STEPPED ROOF TRUSS 2. 2x4 FLAT @ 24" OC. SEE 2/S5.0 3. SEE 2/S5.0 FOR CONNECTION 4. ROOF SHEATHING 5. (2) NAILS SHEATHING TO EA TRUSS 6. 2x4 FLAT CONTINUOUS ALONG HIP-LINE 7. NAIL @ 6" OC 8. (2) NAILS 2x4 FLAT TO EA TRUSS 85 3 3 1 24 4 6 7 1. DBL GIRDER TRUSS 2. ROOF TRUSS 3. ROOF SHEATHING 4. SHAPED BLKG 5. HEADER PER PLAN 6. JAMB PER PLAN 7. SIMPSON H10A-2 @ GIRDER TRUSS 8. SIMPSON H10A @ ROOF TRUSS 9. SIMPSON LSTA24 @ HEADER TO TRIM STUD 5 3 8 9 271 4 6 NOTES: A. INSTALL ALL SIMPSON HARDWARE OVER WALL SHEATHING B. WALL SHEATHING NOT SHOWN FOR CLARITY 1. ROOF SHEATHING 2. TRUSS @ 16" OC 3. SIMPSON H10A TYP 4. SIMPSON LSTA18 5. 4x8 BEAM 6. HEADER PER PLAN 5 1 3 4 2 6 NOTES: A. INSTALL ALL SIMPSON HARDWARE OVER WALL SHEATHING B. WALL SHEATHING NOT SHOWN FOR CLARITY 4 (10'-0" @ SIM) 12 4 12 4 12 4 12 4 SECTION A-A SCALE: 1 1/2" = 1'-0" BETWEEN TRUSSES BLOCKING INSET INSET BETWEEN DRAG MEMBERS 12 4 12 4 BETWEEN TRUSSES BLOCKING INSET 12 4 65123 B C 4 A D 651234 B C A D STAMP JOB N0.: CHECKED BY: SHEET NO. DRAWN BY: DATE: C A L L E N G I N E E R I N G , P A St r u c t u r a l E n g i n e e r s 29 3 9 N o r t h C o l e R d , S u i t e 1 0 2 B o i s e , I D 8 3 7 0 4 MO Y L E -BO Y D SP O R T S C O U R T & G A R A G E FR A M I N G D E T A I L S S4.0 23113 AMC SMC 07-07-2023 37 6 6 W a g o n T r a i l R d R e x b u r g , I d a h o MR K D A T E D E S C R I P T I O N