Loading...
HomeMy WebLinkAboutHIGH STRENGTH BOLTING REPORT 2 - 23-00865 - 4821 Thunderbird Loop - Heaven's Best - RemodelInspection Details Date Contractor Inspector Weather Permit Number 04/01/2024 Teton West Steel Kirby, Shane Cloudy Not Provided Project Specifications: Snug Tight only Full Tension/Slip Critical Full Tension/Slip Critical: Turn­of­the­Nut method Calibrated Wrench method Direct Tension Indicators ­ Load­Indicating Washers Direct Tension Indicators ­Twist­Off­Bolts (”Lejune” bolts) Bolt Type: ASTM A­325 ASTM A­490 Other Bolt Type Other: Bolt size Diameter Length Varies Varies Washer Specifications: Hardened washers Plate washers None required General Conditions Faying surfaces flush and in full contact Faying surfaces free from paint, oil, etc. Visually monitored turn­of­the­nut method Verified Installation equipment and bolts using Skidmore­ Wilhelm tension measuring device Visually Inspected twist­off bolts Washers at slotted holes under turned element Verified a minimum of 2 bolts per connection or 10% of all bolts Reference Drawing Sheet and Detail, and Approved RFI:VP Building drawings #1, #20 and #24 Location(s):Roof framing. Grid lines as to E and 1 to 8 Notes:Results of today’s bolting inspection were reported to Me. Brad Anderson with Teton Wst Steel Work inspected was: in compliance in compliance, except as noted in comments section reinspection/retesting required Note: The recording of false, fictitious, or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. ✔ ✔ ✔ ✔ ✔ ✔ High Strength Bolting Report ­00Report #: Final 04/01/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: Teton West of Idaho, LLC PO Box 176 Rigby, ID 83442 Project: E240543n Venture Builders, 3205 W 5000 S, Rexburg, ID, NDE 3205 W 5000 S Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 1 of 2Page 1 of 1Page 1 of 2 High Strength Bolting Report ­00Report #: Final 04/01/2024Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: Teton West of Idaho, LLC PO Box 176 Rigby, ID 83442 Project: E240543n Venture Builders, 3205 W 5000 S, Rexburg, ID, NDE 3205 W 5000 S Rexburg, ID 83440 These test results are only based upon the actual items observed, sampled, inspected or tested as part of the Services. Unless noted otherwise, test results comply with the acceptance criteria in the most recent client­ approved project plans and specifications. We use the simple acceptance/rejection decision rule; accordingly, measurement uncertainty is not applied in this determination unless required by project plans and specifications or specified by contract. This report shall not be reproduced, except in full, without prior written approval from Atlas. The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Page 2 of 2Page 1 of 1Page 2 of 2 Reviewed and Approved by: Herb Elliott 04/01/2024