Loading...
HomeMy WebLinkAboutREDLINED PLANS 2 - 23-00865 - 4821 Thunderbird Loop - Heaven's Best - RemodelAuthor Name Author Email Author Phone No.: Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : Heaven's Best - Remodel Address : 4821 Thunderbird Loop Suite #101 Application Type : Document Filename : Thunderbird - Popout Girts_11.16.2023.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments S1.0 Free Text Alex Owens : Electrical Open 1 No electrical plans provided. Please provide electrical plans including panel schedule, service size, and available fault current calculation. # 23-00865 Madison County - Commercial Remodel Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 02.12.2024 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) GENERAL STRUCTURAL NOTES (APPLY UNLESS NOTED OTHERWISE ON PLANS/DETAILS) GENERAL REQUIREMENTS: 1.THE STRUCTURAL SYSTEMS AND MEMBERS DEPICTED HEREIN HAVE BEEN DESIGNED PRIMARILY TO SAFEGUARD AGAINST MAJOR STRUCTURAL DAMAGE AND LOSS OF LIFE, NOT TO LIMIT DAMAGE OR MAINTAIN FUNCTION (IBC SECTION 101.3). 2.THESE DRAWINGS, AND THEIR ASSOCIATED STRUCTURAL CALCULATIONS, HAVE BEEN PERFORMED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE STRUCTURAL ENGINEER'S IN THIS OR SIMILAR LOCALITIES. THEY NECESSARILY ASSUME THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKMEN WHO HAVE A WORKING KNOWLEDGE OF THE INTERNATIONAL BUILDING CODE CONVENTIONAL FRAMING REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR FRAMING ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, IT IS UNDERSTOOD THAT THE CONTRACTOR WILL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR ALL MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3.THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION SUCH THAT DESIGN LIVE LOAD PER SQUARE FOOT AS STATED HEREIN IS NOT EXCEEDED. OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF AN OPTION IS USED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES, AND SHALL COORDINATE ALL DETAILS. 4.WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. TYPICAL DETAILS AND NOTES ARE NOT NECESSARILY INDICATED ON THE PLANS, BUT SHALL APPLY NONE-THE-LESS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. DETAILS MAY SHOW ONLY ONE SIDE OF CONNECTION OR MAY OMIT INFORMATION FOR CLARITY. 5.ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ARCHITECT AND STRUCTURAL ENGINEER. 6.ANY INSPECTIONS, SPECIAL (IBC CHAPTER 17) OR OTHERWISE THAT ARE REQUIRED BY THE BUILDING CODES, LOCAL BUILDING DEPARTMENTS, OR BY THESE PLANS SHALL BE DONE BY AN INDEPENDENT INSPECTION COMPANY OR THE BUILDING DEPARTMENT, SITE VISITS BY THE STRUCTURAL ENGINEER DO NOT CONSTITUTE AN OFFICIAL INSPECTION, UNLESS SPECIFICALLY CONTRACTED FOR. 7.SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS IN ADDITION TO ITEMS REQUIRED BY ARCHITECTURAL SPECIFICATIONS, THE CONTRACTOR SHALL REVIEW ALL SHOP DRAWINGS PRIOR TO SUBMITTAL. ITEMS NOT IN ACCORDANCE WITH CONTRACT DRAWINGS SHALL BE FLAGGED UPON HIS REVIEW. VERIFY ALL DIMENSIONS WITH ARCHITECT. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM ORIGINAL CONTRACT DRAWINGS SHALL BE CLOUDED. ANY OF THE AFOREMENTIONED WHICH ARE NOT CLOUDED OR FLAGGED BY SUBMITTING PARTIES, SHALL NOT BE CONSIDERED APPROVED AFTER THE STRUCTURAL ENGINEER'S REVIEW, UNLESS NOTED ACCORDINGLY. ANY ENGINEERING PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW, SHALL BEAR THE SEAL OF A STRUCTURAL ENGINEER REGISTERED IN THE APPROPRIATE STATE. THE SHOP DRAWINGS DO NOT REPLACE THE ORIGINAL CONTRACT DRAWINGS. ITEMS OMITTED OR SHOWN INCORRECTLY AND ARE NOT FLAGGED BY THE STRUCTURAL ENGINEER ARE NOT TO BE CONSIDERED CHANGES TO ORIGINAL DRAWINGS. THE ADEQUACY OF ENGINEERING DESIGNS AND LAYOUT PERFORMED BY THE OTHERS RESTS WITH THE DESIGNING OR SUBMITTING AUTHORITY. REVIEWING IS INTENDED ONLY AS AN AID TO THE CONTRACTOR IN OBTAINING CORRECT SHOP DRAWINGS. RESPONSIBILITY FOR CORRECTNESS SHALL REST WITH THE CONTRACTOR. ALLOW (5) WORKING DAYS FOR THE STRUCTURAL ENGINEER'S REVIEW. ONE COPY OF EACH SUBMITTAL WILL BE RETAINED FOR THE STRUCTURAL ENGINEER'S RECORDS. FOUNDATION NOTES: 1.FOUNDATIONS DESIGNED IN CONFORMANCE WITH RECOMMENDATIONS BY: ENGINEERING TESTING CONSULTANTS, INC. REPORT NO. 3456 DATED JANUARY 1, 2007. 2.SITE PREPARATION AND GRADING REQUIREMENTS OF THE SOIL REPORT AND ANY ADDENDUM'S SHALL BE COMPLETED PRIOR TO CONSTRUCTION OF FOUNDATIONS. ANY TESTS OR INSPECTIONS REQUIRED BY THE SOIL REPORT SHALL BE PERFORMED PRIOR TO PLACEMENT OF FOUNDATION REINFORCING STEEL OR CONCRETE. ALTERATIONS TO SITE PREPARATION OR GRADING SHALL BE REPORTED TO THE GEOTECHNICAL ENGINEER PRIOR TO FOUNDATION CONSTRUCTION. (USE THE NEXT 4 PARAGRAPHS IF THERE IS NO SOIL REPORT) 1.IN LIEU OF A GEOTECHNICAL REPORT: THE FOUNDATION HAS BEEN DESIGNED ACCORDING TO THE RECOMMENDATIONS OF CHAPTER 18 OF THE IBC. 2.THE SOIL DESIGN VALUES LISTED BELOW HAVE BEEN APPROVED BY THE CITY/COUNTY BUILDING DEPARTMENT, CONTINGENT THAT THE SOIL ON THE SITE PREDOMINATELY CONSISTS OF SAND AND/OR GRAVEL. SPECIFIC SOIL CLASSIFICATIONS SHOULD BE ONE OF THE FOLLOWING: SANDY GRAVEL OR GRAVEL(GW OR GP), SAND(SW AND SP), SILTY SAND(SM), CLAYEY SAND(SC), SILTY GRAVEL(GM), OR CLAYEY GRAVEL(GC). THESE SOIL CLASSIFICATIONS CAN BE FOUND IN TABLE 1806.2 OF CHAPTER 18 OF THE IBC. VERIFICATION OF SOIL CLASSIFICATION IS THE RESPONSIBILITY OF THE CONTRACTOR. 3.A ONE-THIRD INCREASE IN BEARING PRESSURES IS ALLOWED WITH SEISMIC OR WIND LOAD COMBINATIONS. LATERAL BEARING AND LATERAL SLIDING RESISTANCE MAY BE COMBINED. 4.ALL FOUNDATIONS SHALL BEAR ON COMPACTED ENGINEERED FILL OR COMPETENT NATIVE SOIL SUBBASE COMPACTED TO 95% DRY DENSITY (STANDARD PROCTOR). GRADE IS DEFINED AS LOWEST ADJACENT GRADE WITHIN 5 FEET OF THE BUILDING FOR PERIMETER FOOTINGS. WHERE EXTERIOR PAVING OR CONCRETE IS DIRECTLY ADJACENT TO BUILDING, GRADE IS DEFINED AS TOP OF EXTERIOR PAVING AT LEAST 5 FEET FROM BUILDING. CONCRETE FOOTING EXCAVATIONS SHALL BE CLEAN AND FREE OF LOOSE DEBRIS OR UN-COMPACTED MATERIAL AT TIME OF CONCRETE PLACEMENT. 5.CONCRETE SLABS ON GRADE SHALL BE SUPPORTED ON A 4 INCH (MIN) LAYER OF FREE-DRAINING GRANULAR MAT (DRAINAGE FILL COURSE). THE MAT SHOULD CONSIST OF A WELL GRADED SAND AND GRAVEL MIXTURE WITH MAXIMUM 3/4-INCH CRUSHED AGGREGATE. THE GRANULAR MAT SHOULD BE COMPACTED TO NO LESS THAN 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D1557. 6.BACKFILL AGAINST RESTRAINED WALLS SHALL NOT BE PLACED UNTIL AFTER THE WALLS ARE SUPPORTED BY THE COMPLETION OF INTERIOR FLOOR SYSTEMS AND CONCRETE OR GROUT STRENGTH HAS REACHED THE 28 DAY STRENGTH LISTED BELOW. THE SOIL DESIGN VALUES FOR THE FOUNDATION ARE: ALLOWABLE BEARING PRESSURE 1500 PSF ALLOWABLE LATERAL BEARING PRESSURE 150 PSF/FT ALLOWABLE LATERAL SLIDING COEFFICIENT 0.25 LATERAL BACKFILL PRESSURE (UNRESTRAINED)30 PSF/FT LATERAL BACKFILL PRESSURE (RESTRAINED)50 PSF/FT FOUNDATION BEARING DEPTH 36" BELOW FINISHED GRADE CONCRETE: 2.ALL NORMAL WEIGHT CONCRETE SHALL BE REGULAR WEIGHT OF 150 POUNDS PER CUBIC FOOT USING HARD-ROCK AGGREGATES. AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. 3.LAP SPLICES FOR BEAMS AND FLOOR SLABS SHALL BE ACCORDING TO CHAPTER 12 OF ACI 318 OR LAP SCHEDULE ON THESE DRAWINGS. STAGGER SPLICES A MINIMUM OF ONE LAP LENGTH. NO TACK WELDING OF REINFORCING BARS ALLOWED WITHOUT PRIOR REVIEW OF PROCEDURE WITH THE STRUCTURAL ENGINEER. LATEST ACI CODE AND DETAILING MANUAL APPLY. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. VERTICAL WALL BARS SHALL BE SPLICED AT OR NEAR FLOOR LINES. 4.ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING STEEL NOT NOTED AS "CLEAR" OR "CLR" ARE TO CENTER OF STEEL. MINIMUM COVER FOR NON-PRESTRESSED CONCRETE REINFORCING SHALL BE AS FOLLOWS: 5.MAXIMUM SLUMP FOR ALL CONCRETE SHALL BE 6". PORTLAND CEMENT SHALL CONFORM TO ASTM C150. TYPE V CEMENT SHALL BE USED FOR CONCRETE IN CONTACT WITH ALKALINE SOIL, AND TYPE II ELSEWHERE. 6.NO MORE THAN 90 MINUTES SHALL ELAPSE BETWEEN CONCRETE BATCHING AND CONCRETE PLACEMENT UNLESS APPROVED BY THE TESTING AGENCY. 7.CONCRETE PLACEMENT AND QUALITY SHALL BE PER RECOMMENDATIONS IN ACI 614, ACI 301 AND ACI 318. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS ON GRADE NEED BE VIBRATED ONLY AROUND AND UNDER FLOOR DUCTS, ETC. CAST CLOSURE POUR, WHERE SHOWN ON PLANS AROUND COLUMNS AFTER COLUMN DEAD LOAD IS APPLIED. REMOVE ALL DEBRIS FROM FORMS BEFORE PLACING CONCRETE. ALL ITEMS TO BE CAST IN CONCRETE SUCH AS REINFORCING, DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY POSITIONED IN THE FORMS BEFORE PLACING THE CONCRETE. 8.ALL CONCRETE SLABS ON GRADE SHALL BE DIVIDED INTO AREAS BY CONTROL JOINTS (KEYED OR SAW CUT) SUCH THAT ONE SLAB AREA DOES NOT EXCEED A MAXIMUM LENGTH OF 24 TIMES THE SLAB THICKNESS IN BOTH DIRECTIONS (EXAMPLE: 4" SLAB = 8'-0" LENGTH). SQUARE LAYOUTS ARE PREFERRED, BUT THE SLAB GEOMETRY MAY DICTATE OTHERWISE. THE RATIO OF THE LONG TO SHORT DISTANCE SHALL NOT EXCEED 1.3. IT IS RECOMMENDED THAT SAW CUTS BE MADE WITHIN 16 HOURS OF CONCRETE BATCHING. KEYED CONTROL JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING POURING, ALL OTHER JOINTS MAY BE SAW CUT. 9.HORIZONTAL PIPES AND ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE AND SLABS ON GRADE EXCEPT WHERE SPECIFICALLY APPROVED OR NOTED BY THE STRUCTURAL ENGINEER. PIPES AND CONDUITS SHALL NOT IMPAIR THE STRENGTH OF THE WORK. 10.FLY ASH MAY BE USED ONLY IF PERMITTED BY ARCHITECTURAL SPECIFICATIONS AND SHALL BE LIMITED TO 18 PERCENT OF CEMENTITIOUS MATERIALS AND SHALL HAVE A REPLACEMENT FACTOR OF 1.2 RELATIVE TO CEMENT REPLACED. NO FLY ASH ADDITIVES SHALL BE USED IN FLATWORK OR ARCHITECTURALLY EXPOSED CONCRETE. 11.COLD/HOT WEATHER CONCRETE CONSTRUCTION: PROTECT CONCRETE FROM DAMAGE OR REDUCED STRENGTH IN COMPLIANCE WITH ACI 305 AND 306. 12.CONCRETE MIXES SHALL BE DESIGNED BY A CERTIFIED LABORATORY AND APPROVED BY THE STRUCTURAL ENGINEER. 13.LIMIT ALKALI-SILICA REACTION (ASR) TO 0.1% EXPANSION AT 28 DAYS IN CONCRETE MIX AT ALL EXTERIOR CONCRETE AND INTERIOR CONCRETE EXPOSED TO MOISTURE. LOCATION:MINIMUM COVER TOLERANCE CAST AGAINST EARTH (FOOTINGS)3"± 3 8" SLABS ON GRADE 112"± 14" EXPOSED TO EARTH OR WEATHER - #5 AND SMALLER 112"± 3 8" EXPOSED TO EARTH OR WEATHER - #6 AND LARGER 2"± 3 8" NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND ROOF SLAB 1"18" STRUCTURAL SLABS AND WALLS 3 4"18" BEAMS AND COLUMNS (PRIMARY) REINFORCEMENT, TIES, STIRRUPS AND SPIRALS 112"3 8" 1. MINIMUM 28 DAY CONCRETE STRENGTH SHALL BE AS FOLLOWS: USE:CONCRETE STRENGTH: MAX W/C RATIO AIR ENTRAINMENT FOOTINGS 3500 PSI 0.50 5.5% ± 1% FOUNDATION WALLS 4500 PSI 0.45 5.5% ± 1% INTERIOR CONCRETE SLABS ON GRADE 3500 PSI 0.45 N/A REINFORCING STEEL: 1.ASTM A615 GRADE 60 (FY = 60 KSI) DEFORMED BARS FOR ALL BARS #4 AND LARGER. ASTM A615 GRADE 40 (FY = 40 KSI) DEFORMED BARS FOR ALL BARS #3 AND SMALLER. GRADE 60 DEFORMED BARS SHALL BE USED FOR CONCRETE WALLS, BEAMS, ELEVATED SLABS AND COLUMN REINFORCING. 2.WELDING OF REINFORCING BARS SHALL BE MADE ONLY TO ASTM A706 GRADE 60 BARS AND ONLY USING E90 SERIES RODS. WELDING OF REINFORCING BARS SHALL BE MADE ONLY AT LOCATIONS SHOWN ON PLANS OR DETAILS. 3.REINFORCING BAR SPACING GIVEN ARE MAXIMUM ON CENTERS. ALL BARS PER CRSI SPECIFICATIONS AND HANDBOOK. DOWEL ALL VERTICAL REINFORCING TO FOUNDATION. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. WOOD: 1.GENERAL: DO NOT NOTCH OR DRILL JOISTS, BEAMS, OR LOAD BEARING STUDS WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER THROUGH THE ARCHITECT. DOUBLE UP JOISTS AND BLOCKING UNDER PARTITIONS. PROVIDE 2" (NOMINAL) SOLID BLOCKING AT SUPPORTS OF ALL JOISTS. UNLESS NOTED OTHERWISE ON PLANS/DETAILS PROVIDE 2x SOLID BLOCKING AT MID-HEIGHT OF BEARING STUD WALLS. ALL NAILING NOT NOTED SHALL BE ACCORDING TO IBC TABLE 2304.10.1. JOIST HANGERS AND OTHER MISC. FRAMING ANCHORS SHALL BE SIMPSON STRONG-TIE COMPANY, INC. OR OTHER MANUFACTURER WITH CURRENT ICC-ES APPROVAL. 2.SAWN LUMBER: FRAMING LUMBER SHALL COMPLY WITH THE LATEST EDITION OF THE GRADING RULES OF THE WESTERN WOOD PRODUCTS ASSOCIATION (WWPA) OR THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB). ALL SAWN LUMBER SHALL BE STAMPED WITH THE GRADE MARK OF AN APPROVED LUMBER GRADING AGENCY. SAWN LUMBER SHALL HAVE THE FOLLOWING MINIMUM GRADE UNLESS NOTED OTHERWISE IN SCHEDULES: USE:MATERIAL: 2x4 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) 2x6 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) JOISTS, TOP PLATES AND ALL OTHER SAWN LUMBER DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) BEAMS AND POSTS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) LOCATION:NOMINAL THICKNESS: SPAN INDEX RATING: EDGE ATTACHMENT: FIELD ATTACHMENT: WALL 7 16" OR 12"24 16 8d AT 6" O.C.8d AT 12" O.C. ROOF 7 16" OR 12"24 16 8d AT 6" O.C.8d AT 12" O.C. ROOF 15 32" OR 12"32 16 8d AT 6" O.C.8d AT 12" O.C. ROOF 19 32" OR 5 8"40 20 10d AT 6" O.C.10d AT 12" O.C. ROOF 23 32" OR 3 4"48 24 10d AT 6" O.C.10d AT 12" O.C. ROOF 7 8"60 32 10d AT 6" O.C.10d AT 12" O.C. FLOOR 3 4" T&G 48 24 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 7 8" T&G 60 32 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. 3.PLYWOOD: ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING CONFORMING TO STANDARD PS 1-95. LAY UP PLYWOOD WITH FACE GRAIN IN PERPENDICULAR TO SUPPORTS (ON ROOFS WHERE PLYWOOD IS LAID UP WITH FACE GRAIN PARALLEL TO SUPPORTS, USE A MINIMUM OF 5-PLY PLYWOOD, STAGGER JOINTS). ALL NAILING, COMMON NAILS. BLOCKING AT PANEL EDGES WHERE INDICATED ON PLANS. ALL PLYWOOD SHALL BE OF THE FOLLOWING NOMINAL THICKNESS, SPAN/INDEX RATING AND SHALL BE NAILED AS FOLLOWS UNLESS NOTED OTHERWISE ON THE PLANS: STEEL: 1.MATERIALS: ROLLED W SHAPES, SHALL CONFORM TO ASTM A992 (FY=50 KSI). ALL OTHER STRUCTURAL STEEL SHAPES, ROLLED SECTIONS, BARS AND PLATES SHALL CONFORM TO ASTM A36 (FY = 36 KSI). ALL PIPE STEEL SHALL BE ASTM A501 (FY = 36 KSI) OR ASTM A53, TYPE E OR S, GRADE B (FY = 35 KSI). ALL TUBULAR STEEL SHALL BE ASTM A500 GRADE C (FY = 50 KSI). 2.ALL BOLTS AND STUDS SHALL BE ASTM A307, UNLESS NOTED OTHERWISE. ALL EXPANSION BOLTS TO HAVE CURRENT ICC REPORT RATING FOR MATERIAL INTO WHICH INSTALLATION TAKES PLACE. HEADED STUDS SHALL CONFORM TO ALL REQUIREMENTS OF THE LATEST EDITION OF THE "RECOMMENDED PRACTICES FOR STUD WELDING" AND THE "STRUCTURAL WELDING CODE" PUBLISHED BY AWS. ALL BOLTS, ANCHOR BOLTS, EXPANSION BOLTS, ETC. SHALL BE INSTALLED WITH STEEL WASHERS AT FACE OF WOOD OR AT SLOTTED HOLES IN STEEL SECTIONS. 3.ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH AISC SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, LATEST EDITION. 4.WELDING SHALL BE BY WELDERS HOLDING VALID CERTIFICATES AND HAVING CURRENT EXPERIENCE IN THE TYPE OF WELD SHOWN ON THE DRAWINGS OR NOTES. ALL WELDING SHALL USE E70 SERIES LOW HYDROGEN RODS UNLESS NOTED OTHERWISE. ALL WELDING PER LATEST AMERICAN WELDING SOCIETY STANDARDS. ALL WELDS ON DRAWINGS ARE SHOWN AS SHOP WELDS. CONTRACTOR MAY SHOP WELD OR FIELD WELD AT HIS DISCRETION. ALL FULL PENETRATION WELDS SHALL BE TESTED AND CERTIFIED BY AN INDEPENDENT TESTING LABORATORY. 5.STEEL TO STEEL BOLTED CONNECTIONS: HIGH STRENGTH BOLTS SHALL BE ASTM A325N AND SHALL BE INSTALLED AS BEARING-TYPE CONNECTIONS WITH THREADS INCLUDED IN SHEAR PLANE (TYPE "N" CONNECTION UNLESS NOTED OTHERWISE). BOLTS MAY BE TIGHTENED USING ANY AISC APPROVED METHOD. 6.DRYPACK SHALL BE 5,000 PSI FIVE STAR NON-SHRINK GROUT OR EQUIVALENT. INSTALL DRYPACK UNDER BEARING PLATES BEFORE FRAMING MEMBER IS INSTALLED. AT COLUMNS, INSTALL DRYPACK UNDER BASE PLATES AFTER COLUMN HAS BEEN PLUMBED BUT PRIOR TO FLOOR OR ROOF INSTALLATION. SHEET INDEX SHEET DESCRIPTION DETAILS S1.0 GENERAL STRUCTURAL NOTES --- S1.1 TYPICAL DETAILS T-SERIES S2.0 FOUNDATION PLAN --- S2.1 MEZZANINE FRAMING PLAN --- S3.0 FOUNDATION DETAILS 100 - SERIES S4.0 FRAMING DETAILS 200 - SERIES S5.0 POP-OUT FRAMING ELEVATIONS 300 - SERIES CAST IN PLACE CENTERLINE CENTERLINE OF BEAM CENTERLINE OF COLUMN CENTERLINE OF WALL CLEAR CONCRETE CONCRETE CONTROL JOINT CONCRETE SAWCUT JOINT CONCRETE MASONRY UNIT CONNECTION CONTINUOUS DEAD LOAD DOWN DRAWING(S) EQUAL EQUIPMENT EXPANSION JOINT EACH WAY FINISHED FLOOR FACE OF STEEL FACE OF WALL GAUGE GALVANIZED GENERAL STRUCTURAL NOTES CENTERLINE OF FOOTING FACE OF MEMBER EXPANSION BOLT EDGE OF SLAB DIAMETER GALV GSN DN. DWG(S) EQ EQUIP EXP. JT (E.J.) E.W. F.F. F.O.S. F.O.W. GA F.O.M. EXP. BOLT E.O.S. Ø OR DIA. C.I.P. C L C.L.B. C.L.C. C.L.W. CLR CONC C.C.J. C.S.J. C.M.U. CONN. CONT D L C.L.F. W/WITH W/O WITHOUT T.O.P. U.N.O. W.W.F. TYP VERT T.O.S. T.O.W. T.O.D. T.O.F. T.O.L. T.O.M. STD T.O.B. T L SLH SLV SIM SQ PSF PSI REINF PREFAB OPP P.C. PLF N.T.S. O.C. O.F.W. TOP OF FOOTING UNLESS NOTED OTHERWISE WELDED WIRE FABRIC TOP OF MASONRY TOP OF PLATE TOP OF STEEL TOP OF WALL TYPICAL VERTICAL STANDARD TOP OF BEAM TOP OF DECK TOP OF LEDGER TOTAL LOAD OUTSIDE FACE OF WALL PRECAST CONCRETE POUNDS PER LINEAR FOOT POUNDS PER SQUARE INCH SHORT LEG VERTICAL SHORT LEG HORIZONTAL REINFORCING SIMILAR SQUARE NOT TO SCALE ON CENTER OPPOSITE PREFABRICATED AGGREGATE BASE COURSE AIR CONDITIONER ABOVE FINISHED FLOOR ALTERNATE ANCHOR BOLT AT (MEASUREMENT) BEAM BOTTOM OF BEAM BOTTOM OF DECK BEARING BELOW FINISHED FLOOR BOTTOM OF FOOTING A.B.C. A/C A.F.F. ALT A.B. @ BM B.O.B. B.O.D. BRG B.F.F B.O.F. ABBREVIATIONS LBS (#) MFR('S) M.C.J. MECH N/A LLV LLH HORIZ K(KIP) L L LONG LEG VERTICAL MANUFACTURER('S) MASONRY CONTROL JOINT NOT APPLICABLE LONG LEG HORIZONTAL POUNDS MECHANICAL HORIZONTAL 1000 POUNDS LIVE LOAD EXISTING(E) MIN MINIMUM MAX MAXIMUM POUNDS PER SQUARE FOOT GLUED-LAMINATED BEAMGLB PFT PREFAB FLOOR TRUSSES PRT PREFAB ROOF TRUSSES I.F.W.INSIDE FACE OF WALL PT PRESSURE TREATED CONCRETE COLUMNC.C. RME ROOF MOUNTED EQUIPMENT GIRDER TRUSSGT SCREWS AT FLOOR SHEATHING SHALL BE #8 SCREWS AND SHALL PENETRATE AT LEAST 112" INTO THE SUPPORTING MEMBER. ALL FLOOR SHEATHING SHALL BE GLUED TO SUPPORTING MEMBERS WITH AN APA AFG-01 QUALIFIED ADHESIVE. PLYWOOD ALTERNATE: AMERICAN PLYWOOD ASSOCIATION PERFORMANCE RATED SHEATHING MAY BE USED AS AN ALTERNATE TO PLYWOOD WITH PRIOR APPROVAL OF OWNER, ARCHITECT AND ROOFER. IT MAY NOT BE USED ON ROOFS WHERE BUILT-UP ROOF SYSTEM IS TO BE GUARANTEED BY ROOFER. RATED SHEATHING SHALL COMPLY WITH CURRENT ICC-ES REPORTS AND SHALL HAVE A SPAN RATING EQUIVALENT TO OR BETTER THAN THE PLYWOOD IT REPLACES. ATTACHMENT AND THICKNESS (WITHIN 132") SHALL BE THE SAME AS THE PLYWOOD IT REPLACES. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 4.NOMINAL 2x AND 3x DECKING. TONGUE AND GROOVE TYPE. MINIMUM Fb = 1,600 PSI, MINIMUM E = 1,300,000 PSI. INSTALL WITH TONGUES UP SLOPE ON PITCHED ROOFS, AND OUTWARD IN THE DIRECTION OF LAYING ON FLAT ROOFS. NAIL EACH PLANK WITH 16d TOENAIL (THRU THE TONGUE) AND 16d FACE NAIL AT EACH SUPPORT. DECK SHALL BE INSTALLED AS SIMPLE SPAN WITH ALL PLANKS BEARING ON TWO SUPPORTS. FOR REFERENCE AND/OR ADDITIONAL INFORMATION SEE AITC 117-2010. 5.GLUED-LAMINATED BEAMS (GLB): GLUED-LAMINATED BEAMS SHALL BE DOUGLAS FIR COMBINATION AT 24F-V4 AT SIMPLE SPAN BEAMS AND 24F-V8 AT MULTI-SPAN AND CANTILEVERED BEAMS WITH THE FOLLOWING MINIMUM PROPERTIES: FB = 2,400 PSI, FV = 190 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,800 KSI. ALL BEAMS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. BEAMS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. CAMBER AS SHOWN ON DRAWINGS. STANDARD CAMBER IS BASED ON A RADIUS OF CURVATURE OF 5000 FEET. 6.GLUED-LAMINATED COLUMNS: GLUED-LAMINATED COLUMNS SHALL BE DOUGLAS FIR COMBINATION 3 WITH THE FOLLOWING MINIMUM PROPERTIES: FBY = 2,100 PSI, FBX = 2000 PSI, FVY = 230 PSI, FVX = 265 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,900 KSI. ALL COLUMNS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. COLUMNS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. 7.LAMINATED VENEER LUMBER (LVL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LVLs SHALL BE: FB = 2,600 PSI, FV = 285 PSI, E = 2,000 KSI. 8.PARALLEL STRAND LUMBER (PSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR PSLs SHALL BE: FB = 2,900 PSI, FV = 290 PSI, E = 2,200 KSI. 9.LAMINATED STRAND LUMBER (LSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LSLs SHALL BE: FB = 2,325 PSI, FV = 310 PSI, E = 1,550 KSI. 10.SILL PLATES RESTING ON CONCRETE OR MASONRY SHALL BE OF TREATED FIR. SHEAR WALLS AND EXTERIOR WALL SILLS AT CONCRETE SLAB SHALL HAVE A MINIMUM OF (2) ANCHOR BOLTS PER PIECE. PROVIDE ANCHOR BOLT AT 9" MAXIMUM, 4" MINIMUM FROM THE END OF EACH PIECE AT SPLICE OR END OF WALL. MAXIMUM ANCHOR BOLT SPACING SHALL BE 72" ON CENTER UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. ALL ANCHOR BOLTS (OTHER THAN BOLTS FOR HOLDOWNS) SHALL EMBED 7" INTO CONCRETE. ANCHOR BOLTS FOR HOLDOWNS SHALL NOT BE CONSIDERED AS PART OF REQUIRED ANCHOR BOLTS ON SHEAR WALLS. ALL EXTERIOR WALLS SHALL BE SECURED WITH MINIMUM ANCHOR BOLTS. INTERIOR WALLS MAY BE SECURED TO CONCRETE WITH EITHER ANCHOR BOLTS OR POWER DRIVEN SHOT PINS UNLESS NOTED OTHERWISE ON PLANS. 11.BOLTING: ALL BOLTS IN WOOD CONNECTIONS SHALL CONFORM TO ASTM A307. BOLTS SHALL BE INSTALLED IN HOLES BORED WITH A BIT 116" LARGER THAN THE Ø (DIAMETER) OF THE BOLT. BOLTS AND NUTS SEATING ON WOOD SHALL HAVE CUT STEEL WASHERS UNDER HEADS AND NUTS. NICK THREADS TO PREVENT LOOSENING. 12.PREFABRICATED WOOD TRUSSES: PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED TO SUPPORT SELF WEIGHT PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS. WHERE UNINHABITABLE ATTIC SPACE CAN BE USED FOR STORAGE, A 20 PSF LIVE LOAD ON THE BOTTOM CHORD SHALL BE INCLUDED IN THE ANALYSIS. BRIDGING SIZE AND SPACING BY TRUSS MANUFACTURER UNLESS NOTED OTHERWISE. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED ENGINEER FOR REVIEW PRIOR TO MANUFACTURE FOR BOTH ROOF AND FLOOR TRUSSES WHEN USED. SHOP DRAWINGS SHALL SHOW ANY SPECIAL DETAILS REQUIRED AT BEARING POINTS. ALL CONNECTORS SHALL HAVE CURRENT ICC-ES APPROVAL. ADDITIONAL TRUSSES SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. PER IBC SECTION 2303.4 AND TPI-1: EACH TRUSS SHALL BE LEGIBLY BRANDED, MARKED OR OTHERWISE HAVE PERMANENTLY AFFIXED THERETO THE IDENTITY OF THE COMPANY MANUFACTURING THE TRUSS, THE DESIGN LOADS, AND THE TRUSS SPACING - WITHIN TWO FEET OF THE CENTER OF THE SPAN ON THE FACE OF THE BOTTOM CHORD. PREFABRICATED WOOD/STEEL WEB JOIST/PURLINS (TJI/TJL SERIES OR EQUAL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST EDITION ICC-ES REPORT. CONNECTIONS AND BEARING MATERIAL TO BE DESIGNED AND FURNISHED BY JOIST FABRICATOR. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED STRUCTURAL ENGINEER FOR REVIEW PRIOR TO MANUFACTURE. ADDITIONAL JOISTS SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. BASIS FOR DESIGN: 1.BUILDING CODE: 2018 EDITION OF THE IBC WITH CITY/COUNTY AMENDMENTS. RISK CATEGORY = II 2.VERTICAL LOAD: PER PRE-ENGINEERED BUILDING MANUFACTURER 3.SEISMIC DESIGN PARAMETERS: PER PRE-ENGINEERED BUILDING MANUFACTURER 4.WIND DESIGN PARAMETERS: PER PRE-ENGINEERED BUILDING MANUFACTURER 7. SEISMIC DESIGN PARAMETERS FOR MEZZANINE: ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE IMPORTANCE FACTOR Ie = 1.00 SITE CLASS D SEISMIC DESIGN CATEGORY D MAPPED SPECTRAL RESPONSE ACCELERATIONS S1 = 0.142, SS = 0.366 DESIGN SPECTRAL RESPONSE ACCELERATIONS SD1 = 0.219, SDS = 0.368 PERCENT LIVE LOAD INCLUDED WITH SEISMIC LOADS 25 VERTICAL SHEAR TRANSFER ELEMENTS: PLYWOOD SHEARWALL(S)R = 6.5, CS = 0.057 5. VERTICAL LOADS FOR MEZZANINE: LOCATION LIVE / SNOW LOAD DEAD LOAD FLOOR 125 PSF 15 PSF 6. DEFLECTION LIMITS FOR MEZZANINE: ELEMENTS LIVE LOAD TOTAL LOAD BEAMS L/360 L/240 PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 11 / 1 3 / 2 3 14 1 3 4 D VID B . P O R T E R L I C E N SED PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 St r u c t u r a l E n g i n e e r i n g fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 co n t a c t @ f r o s t s t r u c t u r a l . c o m S1.0 11/13/23 TH U N D E R B I R D B U I L D I N G TE T O N W E S T C O N S T R U C T I O N GT C DB P IF 2 3 - 4 1 1 GE N E R A L S T R U C T U R A L N O T E S TH O R N T O N , I D A H O . . . . . . . . . . . . . . . . . . . . . . AcÑWBWUhf>USBÑdBSEJÑdfcM>VWV•ÑCBWSJWÑ dfcM>VWÑWBWUhf>USBÑdBSEJÑ>EUBiV>EYÑdSEWBÑ JUZWViBW8ÑJWfM>UWÑJ>oW8ÑSEVÑSMS>BSTBWÑXSiBhÑ UiffWEhÑUSBUiBSh>cE• KEYNOTES: 1.FINISHED GRADE WHERE OCCURS 2.DO NOT EXCAVATE A TRENCH CLOSER THAN A 45 DEGREE ANGLE TO BELOW BOTTOM FOOTING OR FOUNDATION 3.BOTTOM OF CONCRETE FOOTING 4.BOTTOM OF TRENCH NOTE: A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPE OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS 1 1 1 2 3 4 FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T1 TRENCH PARALLEL TO CONTINUOUS STRAP FOOTING TD01 NO SCALE KEYNOTES: 1.CONCRETE FOOTING 2.SLEEVE - PROVIDE 12" MINIMUM CLEARANCE AROUND PIPE OR CONDUIT 3.PIPE OR CONDUIT 4.CONCRETE FILL TO BE PLACED BEFORE FOOTING IS POURED - FORM SAME AS FOOTING AND POUR FULL WIDTH OF PIPE TRENCH 5.STEM WALL NOTE: A.NO PIPE SHALL PASS THRU FOOTING OR UNDER COLUMN FOOTINGS. FOR TRENCHES GREATER THAN 3'-6" BELOW BOTTOM OF FOOTING, SEE PIPE PASSING BELOW WALL FOOTING DETAIL. 1 2 3 4 5 5 4 2 1 3 T2 PIPE PASSING UNDER WALL FOOTING IN SHALLOW TRENCH TD02 NO SCALE 6" M I N 8" M I N 3' - 0 " M A X 8" MIN A SECTIONA KEYNOTES: 1.STEM WALL 2.CONCRETE FOOTING 3.1'-6" MAXIMUM - WHERE TRENCH EXCEEDS 1'-6" NOTIFY STRUCTURAL ENGINEER PRIOR TO PLACEMENT OF FOOTINGS 4.BACKFILL AND RECOMPACT TRENCH PER SOILS REPORT AND SPECIFICATIONS 5.BOTTOM OF TRENCH NOTE: A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPES OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS 1 5 4 3 2 3' - 1 " O R G R E A T E R FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T3 PIPE PASSING BELOW FOOTING IN DEEP TRENCH TD03 NO SCALE KEYNOTES: 1.SLOPED FINISH GRADE 2.MINIMUM FOOTING DEPTH PER G.S.N. - 12" MINIMUM 3.DEEPEN FOOTING AS REQUIRED TO ACCOUNT FOR SLOPED GRADE 4.CONCRETE FOOTING NOTE: A.FOR ADDITIONAL INFORMATION, SEE PLANS AND DETAILS 1 4 3 2 5'-0" T4 TYPICAL DETAIL FOR FOUNDATION EMBEDMENT TD04 NO SCALE KEYNOTES: 1.CONCRETE SLAB ON GRADE 2.CONT KEYED JOINT 3.SAWCUT 18" WIDE x 14" SLAB THICKNESS IN DEPTH - CUT SHALL BE MADE SOON ENOUGH TO PREVENT SHRINKAGE CRACKING, BUT NOT SO SOON AS TO CAUSE SPALLING OF THE CONCRETE WHILE SAWING. WORK MUST BE COMPLETE WITHIN 16 HOURS OF CONCRETE PLACEMENT. NOTE: A.KEYED JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING PLACEMENT UNLESS SPECIFICALLY NOTED ON THE PLANS. B."TOOL WET JOINT", "ZIP STRIP", ETC SHALL MATCH SAWCUT REQUIREMENTS 1 2 3 1 12"6"6"12" X SAWCUT JOINT X KEYED JOINT T5 CONTROL JOINTS IN CONCRETE SLAB ON GRADE TD07 NO SCALE 6 MIN BAR OFFSET BAR CLEARANCE SPLICE DETAIL BEND & HOOK DETAILS COLUMN TIES BEAM STIRRUPS "d" 45° "d" "d" 1 2 4 5 6 10 9 8 7 3 1 5 5 9 10 8 KEYNOTES: 1.LAP - SEE G.S.N. 2.MAXIMUM 15 LAP BUT NOT MORE THAN 6" 3.WIRE TIES 4.1d (1" MINIMUM) 5.RADIUS = 3d FOR BARS NOT OVER #8; 4d FOR #9, #10, AND #1 BARS; 5d FOR #14 AND #18 BARS, 5d FOR ALL GRADE 40 BARS WITH 180 DEGREE HOOK 6.4D (4" MINIMUM) 7.12d (90 DEGREE HOOK) 8.6d (4" MINIMUM) 9.135 DEGREE BEND 10.BEND AROUND 112" PIN FOR #3 BARS. BEND AROUND 2" PIN FOR #4 BARS. BEND AROUND 212" PIN FOR #5 BARS. T6 TYPICAL REINFORCING DETAILS TD10 NO SCALE NOTES: 1.TOP BARS ARE ANY HORIZONTAL BARS PLACED SO THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT. 2.UNLESS NOTED OTHERWISE, LAP SPLICES IN CONCRETE BEAMS, SLABS AND WALLS SHALL BE CLASS "B" TENSION LAP SPLICES. BAR SIZE CLASS B TENSION SPLICE LENGTHS f'c = 3,000 PSI f'c = 4,000 PSI f'c = 5,000 PSI HOIRZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HOIRZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HOIRZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS #3 12"12"12"12"12"12" #4 19"15"17"13"15"12" #5 29"23"26"20"23"18" #6 32"25"28"21"25"19" #7 54"41"47"36"42"32" #8 70"54"61"47"54"42" #9 89"68"77"59"69"53" #10 112"87"97"75"87"67" T7 STEEL REINFORCING LAP SPLICES IN CONCRETE TD14 NO SCALE KEYNOTES: 1.CORNER DOWELS TO MATCH HORIZONTAL REINFORCEMENT 2.CONCRETE WALL WITH REINFORCEMENT 3.LAP SPLICE PER TYPICAL STEEL REINFORCING LAP SPLICES IN CONCRETE DETAIL T8 TYPICAL CONCRETE CORNER TD05 NO SCALE 2 1 3 3 KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.WOOD HEADER 3.KING STUD(S) PER PLAN 4.(2) 16d NAILS AT 2" O.C. 5.16d NAILS AT 12" O.C. 6.TRIMMER STUD(S) PER PLAN 2 6 3 1 5 4 5 T13 TYPICAL HEADER CONNECTION TD25 NO SCALE KEYNOTES: 1.NAILS BETWEEN SPLICE LOCATION PER SCHEDULE - STAGGERED 2.DBL 2x TOP PLATE 3.WOOD STUD WALL, SEE PLAN 4.SPLICE OVER STUD 5.SIMPSON ST6224 OR MSTC40 STRAP AT LOCATIONS WHERE PLATES CAN NOT BE SPLICED NOTE: A.DO NOT SPLICE TOP PLATES WITHIN 6'-0" OF ENDS OF PLYWOOD SHEARWALLS. THIS DETAIL REQUIRED AT ALL EXTERIOR WALLS AND OVER SHEARWALLS - NOT REQUIRED AT INTERIOR NON-SHEARWALLS. (30) 16d (24) 16dLESS THAN 20' OVER 20' 4'-0" 6'-0" LENGTH OF WALL (BETWEEN CORNERS)SPLICE LENGTH NAILS ALONGSPLICE LENGTH MINIMUM SPLICE LENGTH PER SCHEDULE T12 ELEVATION - TYPICAL TOP PLATE SPLICE TD24 NO SCALE 4 5 1 3 2 3 2 T11 ELEVATION-TYPICAL 1-STORY SHEARWALL TD19 NO SCALE KEYNOTES: 1.SHEATHING MATERIAL 2.DOUBLE STUDS AT EACH END OF SHEARWALL, EDGE NAIL ALONG DOUBLE STUDS 3.FULL HEIGHT WOOD STUDS 4.BOTTOM PLATE ATTACHMENT 5.SIMPSON STHD TYPE HOLDOWN 6.MIDHEIGHT BLOCKING AND EDGE NAILING REQUIRED 7.SIMPSON "PHD" TYPE HOLDOWN 8.FINISHED FLOOR 9.CONT 2x PT SOLE PLATE 1 3 6 8 7 4 5 2 9 2 6 34 1 5 2 1 74 2 1 3 4 18 AT BEAM AT MID WALL AT TOP PLATE T14 TYPICAL BEAM POCKET TD26 NO SCALE KEYNOTES: 1.WOOD BEAM 2.(2) 16d NAILS AT 2" O.C. 3.KING STUD EACH SIDE OF BEAM 4.SOLID BUILT-UP POST BELOW BEAM 5.STRAP BROKEN TOP PLATE ON SIDE OR TOP 6.CONT DBL 2x TOP PLATE W/ LAP SPLICE PER TYPICAL DETAIL 7.FULL-HEIGHT KING STUD EACH SIDE OF BEAM 8.HGA10 CLIP EACH SIDE 9.FULL-HEIGHT KING STUD AT END OF BEAM 10.FULL-HEIGHT KING STUD, OPPOSITE SIDE OF THE BEAM 2 1 4 AT CORNER 10 9 2 NOTE: A.MINIMUM STAPLING SPECIFIED HEREIN SHALL BE PROVIDED UNLESS NOTED OTHERWISE ON PLANS, DETAILS OR GENERAL STRUCTURAL NOTES 8d COMMON AT 12" O.C. 16 GA STAPLE AT 12" O.C. ALTERNATE FASTENER SCHEDULE ALTERNATE FASTENERSPECIFIED FASTENER 8d COMMON AT 6" O.C. 8d COMMON AT 4" O.C. 15 GA STAPLE AT 12" O.C. 14 GA STAPLE AT 12" O.C. 13 GA STAPLE AT 12" O.C. 16 GA STAPLE AT 4" O.C. 15 GA STAPLE AT 5" O.C. 14 GA STAPLE AT 6" O.C. 13 GA STAPLE AT 6" O.C. 13 GA STAPLE AT 5" O.C. 14 GA STAPLE AT 4" O.C. 15 GA STAPLE AT 3" O.C. 16 GA STAPLE AT 2.5" O.C. 15 GA STAPLE AT 2" O.C. 14 GA STAPLE AT 3" O.C. 13 GA STAPLE AT 4" O.C. 8d COMMON AT 3" O.C. MATERIAL: 7/16" SHEARWALL OR ROOF SHEATHING NOTES: 1.STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7 16" INCH OUTSIDE DIMENSION. AND INSTALLED WITH CROWN PARALLEL TO THE LONG DIMENSION OF FRAMING MEMBER. 2.FRAMING SHALL BE 3x OR WIDER WHEN NAIL SPACING IS LESS THAN 3 INCHES ON CENTER. 3.ALL STAPLES SHALL HAVE 112" LONG LEGS MINIMUM. 4.STAPLE SIZES AND SPACING PER REPORT NO. ICC-ESR-1539 T9 ALTERNATE SHEATHING STAPLE OPTION TD32 NO SCALE CONNECTION TYPE JOIST OR TRUSS BEARING ON SILL OR GIRDER BRIDGING TO JOIST SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL TOP PLATE TO STUD DOUBLE STUDS, FACE NAIL DOUBLE TOP PLATES CONTINUOUS HEADER TO STUD CEILING JOISTS, LAPS OVER PARTITIONS CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL RAFTER OR TRUSS TO PLATE BUILT-UP CORNER STUDS TOENAIL (4)-8d COMMON (2 1/2" x 0.131") NAILING (3)-8d COMMON (2 1/2" x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES TOENAIL EACH END(2)-3"x 0.131" NAILS (Gun Nail) (2)-3"x 14 GAUGE STAPLES 16d (3 1/2"x 0.135") AT 16" O.C. FACE NAIL 3"x 14 GAUGE STAPLES AT 12" O.C. 3"x 0.131" NAILS (Gun Nail) AT 8" O.C. END NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES SOLE PLATE TO STUD END NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES FACE NAIL 16d (3 1/2"x 0.135") AT 24" O.C. 3"x 14 GAUGE STAPLES AT 8" O.C. 3"x 0.131" NAILS (Gun Nail) AT 8" O.C. FACE NAIL 16d (3 1/2"x 0.135") AT 16" O.C. 3"x 14 GAUGE STAPLES AT 12" O.C. 3"x 0.131" NAILS (Gun Nail) AT 12" O.C. DOUBLE TOP PLATES - FACE NAIL (8)-16d COMMON (3 1/2"x 0.162") (12)-3"x 0.131" NAILS (Gun Nail) (12)-3"x 14 GAUGE STAPLES LAP SPLICE RIM JOIST TO TOP PLATE 8d (2 1/2"x 0.131") AT 6" O.C. 3"x 14 GAUGE STAPLES AT 6" O.C. 3"x 0.131" NAILS (Gun Nail) AT 6" O.C. BLOCKING BETWEEN JOISTS OR RAFTERS TOENAIL (3)-8d COMMON (2 1/2"x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES AND TOP PLATE TOENAIL TOP PLATES, LAPS AND INTERSECTIONS FACE NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES CONTINUOUS HEADER, TWO PIECES 16d COMMON (3 1/2"x 0.162") FACE NAIL AT 16" O.C. ALONG EDGES CEILING JOISTS TO PLATE TOENAIL (3)-8d COMMON (2 1/2"x 0.131") (5)-3"x 0.131" NAILS (Gun Nail) (5)-3"x 14 GAUGE STAPLES FACE NAIL (3)-16d COMMON (3 1/2"x 0.162) (4)-3"x 0.131" NAILS (Gun Nail) (4)-3"x 14 GAUGE STAPLES (3)-16d COMMON (3 1/2"x 0.162) (4)-3"x 0.131" NAILS (Gun Nail) (4)-3"x 14 GAUGE STAPLES FACE NAIL (3)-8d COMMON (2 1/2"x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES TOENAIL TOENAIL 16d COM.(3 1/2"x 0.162") AT 24" O.C. 3"x 14 GAUGE STAPLES AT 16" O.C. 3"x 0.131" NAILS (Gun Nail) AT 16" O.C.FACE NAIL (2)-8d COMMON (2 1/2" x 0.131") USE- SIMPSON A35 AT 48" O.C.-NA- SIMPSON A35 AT EVERY OTHER BLOCK -NA- NOTE: A.MINIMUM NAILING SPECIFIED HEREIN SHALL BE PROVIDED UNLESS NOTED OTHERWISE ON PLANS, DETAILS OR GENERAL STRUCTURAL NOTES B.NAILING NOT NOTED ON THESE PLANS OR DETAILS SHALL BE PER I.B.C. TABLE 2304.10.1 T10 MINIMUM NAILING SCHEDULE - UNLESS NOTED OTHERWISE TD34 NO SCALE PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 11 / 1 3 / 2 3 14 1 3 4 D VID B . P O R T E R L I C E N SED PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 St r u c t u r a l E n g i n e e r i n g fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 co n t a c t @ f r o s t s t r u c t u r a l . c o m S1.1 11/13/23 TH U N D E R B I R D B U I L D I N G TE T O N W E S T C O N S T R U C T I O N GT C DB P IF 2 3 - 4 1 1 TY P I C A L D E T A I L S TH O R N T O N , I D A H O . . . . . . . . . . . . . . . . . . . . . . 1 A B C D E 2 3 4 5 6 7 8 70 ' - 0 " 14 ' - 0 " 21 ' - 0 " 20 ' - 0 " 15 ' - 0 " 190'-0" 17'-6"3'-4"3'-2"20'-4"3'-4"2'-4"20'-4"3'-4"3'-4" 25'-6" 6" 26'-0"24'-0"29'-0"26'-0"29'-4"28'-8"27'-0" 26'-6" 6" 11'-4"3'-4"11'-4" 1'-2" 3'-4"2'-4"14'-0"2'-0"8'-0"14'-0"7'-0"11'-4"11'-4"6'-0"14'-0"9'-4"7'-0"14'-0"2'-4"3'-4"2'-0" 11'-4"12'-4" 5" CONCRETE SLAB ON GRADE OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME FINISH FLOOR = 100'-0" CONCRETE SLAB ON GRADE 1' - 0 " 3'-4" 1'-2" 3'-4" WF16 / W1WF16 / W1 WF 1 6 / W 1 WF 1 6 / W 1 WF16 / W1 WF16 / W1 WF16 / W1 WF16 / W1 WF16 / W1 6" 1'-2" T.O.W. 101'-0" WF 1 0 60 ° TY P 1 3 2 T.O.F. 98'-0" 60 ° TY P T.O.W. 101'-0" T.O.F. 98'-0" F36 F36 F36 F36 2 6" 3 1 1 1 1 1 1 111 1 1 WF 1 0 3 3 WF 1 0 3 3 WF 1 0 3 3 WF 1 0 3 3 WF 1 0 3 3 4 4 F66 F66 F66 F72 F72 F66 F66F66F66F78F78F66 WF16 SC1 F42 SC1 F54 WF20 WF20 WF20 WF 1 6 WF 1 6 WF 1 6 2 2 5 5 5 5 5 55 F48 F36 F36 1'-2"1'-2" 6" 2 2 F36 F36 F36 WF 1 6 / W 1 15 ' - 6 " 27'-8" 24'-0"29'-0"26'-0"29'-4"28'-8"27'-0" 28'-4"28'-8" 15 ' - 6 " 6" 1' - 0 " WF 1 6 / W 1 1' - 0 " 8" 1' - 8 " 8" 2'-91 4" 11'-61 2" 5 6 666 6 6 TYP 101 TYP 101 112 101 102 102 105 103 104 104 106 OPP 103 104 104 104 104 104 104 104 104 104102 102 102 102 102 102 102 102 102 102 105 105 106 TYP 107 108 108 TYP 109 TYP 109 TYP 109 111 111 111 110 107 104 108 112112 112 6 6 SCALE: FOUNDATION PLAN 1/8" = 1'-0" PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 11 / 1 3 / 2 3 14 1 3 4 D VID B . P O R T E R L I C E N SED PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 St r u c t u r a l E n g i n e e r i n g fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 co n t a c t @ f r o s t s t r u c t u r a l . c o m S2.0 11/13/23 TH U N D E R B I R D B U I L D I N G TE T O N W E S T C O N S T R U C T I O N GT C DB P IF 2 3 - 4 1 1 FO U N D A T I O N P L A N TH O R N T O N , I D A H O . . . . . . . . . . . . . . . . . . . . . . POST (P) SCHEDULE NOTES: 1. FOR CONNECTIONS AT EITHER END OF POST, SEE DETAILS. 2. UNO, SEE GENERAL STRUCTURAL NOTES (GSN) FOR LUMBER SPECIES AND GRADE. MARK SIZE SPECIES AND GRADE CONNECTION P1 (2) 2x6 DOUG FIR NO. 2 SEE TYPICAL DETAILS P2 6x6 DOUG FIR NO. 1 SEE PLAN KEYNOTE AND DETAIL SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 5 HEADED ANCHOR ROD EMBED SCHEDULE DIAMETER MINIMUM EMBEDMENT (FROM TOP OF PIER/WALL) 12"12" 5 8"14" 3 4"16" 7 8"18" 1"20" 114"25" FOOTING SCHEDULE NOTES: 1. FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. 2. FOR MINIMUM CLEARANCE (CLR) OF REINFORCING, SEE GENERAL STRUCTURAL NOTES (GSN). MARK LENGTH WIDTH THICK- NESS FOOTING REINFORCING REMARKS F36 36"36"10"(3) #4 EACH WAY, TOP AND BOTTOM --- F42 42"42"10"(5) #4 EACH WAY, BOTTOM --- F48 48"48"12"(4) #4 EACH WAY, TOP AND BOTTOM --- F54 54"54"12"(7) #4 EACH WAY, BOTTOM --- F66 66"66"12"(5) #5 EACH WAY, TOP AND BOTTOM --- F72 72"72"12"(6) #5 EACH WAY, TOP AND BOTTOM --- F78 78"78"12"(6) #5 EACH WAY, TOP AND BOTTOM --- WF10 CONT 10"10"(2) #6 CONT, BOTTOM --- WF16 CONT 16"10"(2) #4 CONT, BOTTOM --- WF20 CONT 20"10"(2) #4 CONT, BOTTOM --- A.VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B.ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C.THE DEPTH OF FOOTING DIMENSION INDICATED IN THE G.S.N. IS A MINIMUM. FOUNDATION CONTRACTOR SHALL COORDINATE WITH THE SOILS REPORT AND OTHER TRADES TO INSURE THAT THESE MINIMUMS ARE SUFFICIENT FOR THE WORK. SEE TYPICAL DETAILS FOR ADDITIONAL REQUIREMENTS. D. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. E. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. F. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. G.W1, W2, ETC. - AS SHOWN ON PLAN INDICATES CONCRETE OR MASONRY WALLS. SEE WALL SCHEDULE FOR ADDITIONAL INFORMATION. H.WF18, WF24, ETC. - AS SHOWN ON PLAN INDICATES A CONTINUOUS WALL FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. I.F36, F48, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. J.P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. K.SC1, SC2, ETC. - AS SHOWN ON PLAN INDICATES A STEEL COLUMN. SEE STEEL COLUMN SCHEDULE FOR ADDITIONAL INFORMATION. COLUMNS START AT THE LEVEL THEY ARE CALLED OUT ON. L.FOR SIDEWALK AND LANDING LOCATIONS, SEE ARCHITECTURAL DRAWINGS. FOUNDATION PLAN NOTES 5 6.7 STEEL COLUMN (SC) SCHEDULE MARK SIZE BASE CONNECTION SC1 HSS4x4x3 16 12"x10"x10" PLATE W/ (4) 3 4"Ø ANCHOR BOLTS W/ 8" MINIMUM EMBEDMENT WALL (W) SCHEDULE MARK THICKNESS AND TYPE VERTICAL REINFORCING HORIZONTAL REINFORCING REMARKS W1 8" CONCRETE #4 AT 18" O.C.#4 AT 18" O.C.--- 1.VERIFY DOOR OPENING W/ METAL BUILDING MANUFACTURER DRAWINGS. 2.(1) #4x20'-0" LONG (10'-0" EACH LEG) HAIRPIN. 3.(1) #6x10'-0" LONG (5'-0" EACH LEG) HAIRPIN. WIDEN GRADE BEAM AT CONCRETE PIER AS NECESSARY TO MAINTAIN 3" CLR AROUND ALL REINFORCING. 4.PROVIDE 14"x36" CONCRETE PIER W/ (16) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER BELOW PORTAL FRAME COLUMN, SIM TO DETAIL 104. 5.EXTEND CONCRETE PIER TO SUPPORT THE MEZZANINE WOOD COLUMN, SEE PLAN FOR DIMENSIONS AND DETAIL 108 FOR ADDITIONAL INFORMATION. 6.STEEL COLUMN, ALIGN WITH PEMB STEEL COLUMN, SEE DETAIL 301. PLAN KEYNOTESX 1 A B C D E 2 3 4 5 6 7 8 B2 B2 B4 B4 B4 B5 B5 B3 B1 OPEN OPEN B4 B4B3 5 5 5 5 5 55 WJ2 WJ 1 WJ2 WJ3 WJ2 WJ2 P1 2 1 P1 P1P1 P1 1 P1 P1 5 TYPICAL FLOOR SHEATHING: 3/4" APA RATED FLOOR SHEATHING W/ 10d COMMON NAILS AT 6" O.C. AT PANEL EDGES / BOUNDARY AND AT 12" O.C. IN THE FIELD. 5 301301 302 P2 4 P1P1 201 202 203 204 205 206 207 208 209 210 211 301 302 555555 5 5 SCALE: MEZZANINE FRAMING PLAN 1/8" = 1'-0" PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 11 / 1 3 / 2 3 14 1 3 4 D VID B . P O R T E R L I C E N SED PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 St r u c t u r a l E n g i n e e r i n g fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 co n t a c t @ f r o s t s t r u c t u r a l . c o m S2.1 11/13/23 TH U N D E R B I R D B U I L D I N G TE T O N W E S T C O N S T R U C T I O N GT C DB P IF 2 3 - 4 1 1 ME Z Z A N I N E F R A M I N G P L A N TH O R N T O N , I D A H O . . . . . . . . . . . . . . . . . . . . . . WOOD JOIST ( ) SCHEDULE MARK JOIST FACE MOUNT HANGER TOP FLANGE HANGER WJ1 2x8 AT 16" O.C.LUS26 LB26 WJ2 117 8" TJI 210 AT 16" O.C.IUS2.06/11.88 ITS2.06/11.88 WJ3 117 8" TJI 560 AT 16" O.C.IUS3.56/11.88 ITS3.56/11.88 WJ BEAM (B) SCHEDULE MARK SIZE B1 (2) 2x6 OR 4x6 OR (2) 13 4x512 LVL B2 (2) 2x8 OR 4x8 OR (2) 13 4x512 LVL B3 (2) 2x10 OR 4x10 OR (2) 13 4x714 LVL B4 (2) 13 4x117 8 LVL B5 63 4x1612 GLB 1.POCKET BEAM INTO WALL PER TYPICAL DETAIL 2.STAIR LANDING FRAMING 3.EXTERIOR WALL FRAMING TO BE 2x6 LSL 1.3E AT 12" 4.ATTACH BEAM TO POST WITH SIMPSON CCQ76SDS2.5 COLUMN CAP 5.STEEL COLUMN, ALIGN WITH PEMB STEEL COLUMN, SEE DETAIL 301 PLAN KEYNOTESX POST (P) SCHEDULE NOTES: 1. FOR CONNECTIONS AT EITHER END OF POST, SEE DETAILS. 2. UNO, SEE GENERAL STRUCTURAL NOTES (GSN) FOR LUMBER SPECIES AND GRADE. MARK SIZE SPECIES AND GRADE CONNECTION P1 (2) 2x6 DOUG FIR NO. 2 SEE TYPICAL DETAILS P2 6x6 DOUG FIR NO. 1 SEE PLAN KEYNOTE AND DETAIL FLOOR FRAMING PLAN NOTES A.VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B.ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C.IF DOUBLE TOP PLATE IS NOTCHED, STEPPED OR BROKEN, PROVIDE A SIMPSON MSTC40 STRAP AT DISCONTINUITY. D.TYPICAL BEARING WALL FRAMING SHALL BE 2x6 STUDS AT 16" O.C. UNO. E.PROVIDE TRIMMER STUDS (TS) AND KING STUDS (KS) AT OPENINGS AS FOLLOWS, U.N.O.: OPENINGS 6'-0" OR LESS, (1) TS & (1) KS, OPENINGS 6'-1" TO 9'-0", (1) TS & (2) KS, 9'-1" TO 12'-0", (2) TS & (3) KS. FOR ATTACHMENT, SEE "TYPICAL HEADER CONNECTION" DETAIL. F. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. G. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. H. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. I.B1, B2, ETC. - AS SHOWN ON PLAN INDICATES A BEAM OR HEADER. SEE BEAM SCHEDULE FOR ADDITIONAL INFORMATION. J.WJ1, WJ2, ETC. - AS SHOWN ON PLAN INDICATES A WOOD JOIST. SEE WOOD JOIST SCHEDULE FOR ADDITIONAL INFORMATION. K.P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. L.FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING CONDITION. 5 6.7 SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 5 KEYNOTES: 1.PRE-ENGINEERED BUILDING BEYOND 2.CONCRETE STEM WALL, SEE PLAN 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE SLAB ON GRADE, SEE PLAN 8.#4 BENT DOWEL AT 18" O.C. 102 PRE-ENGINEERED BUILDING AT CONCRETE FOOTING CS_MB102 NO SCALE 3" CLR 3" CL R 1 5 6 7 8 3 2 3 4 18" 18" KEYNOTES: 1.PRE-ENGINEERED COLUMN, SEE PLAN 2.ANCHOR BOLTS W/ NUT AT BOTTOM 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING AND CONCRETE STEM WALL BEYOND, CONT REINFORCEMENT TROUGH PIER (NOT SHOWN FOR CLARITY) 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE FOOTING, SEE PLAN 8.CONCRETE PIER W/ (6) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 9.CONCRETE SLAB ON GRADE, SEE PLAN 103 PRE-ENGINEERED COLUMN AT CONCRETE FOOTING NO SCALE 3" CLR 3" CL R 7 6 39 3" MIN 1 2 8 5 4 105 PRE-ENGINEERED COLUMN AT CONCRETE FOOTING NO SCALE KEYNOTES: 1.PRE-ENGINEERED COLUMN, SEE PLAN 2.ANCHOR BOLTS W/ NUT AT BOTTOM 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING & CONCRETE STEM WALL BEYOND CONT REINFORCING THROUGH PIER (NOT SHOWN FOR CLARITY) 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE FOOTING, SEE PLAN 8.CONCRETE PIER W/ (6) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 9.CONCRETE SLAB ON GRADE, SEE PLAN 10.HAIRPIN AS OCCURS, SEE PLAN 3" CLR 3" CL R 3" MIN 7 6 310 1 2 8 9 4 5 KEYNOTES: 1.PRE-ENGINEERED BUILDING 2.CONCRETE STEM WALL, SEE PLAN 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE SLAB ON GRADE, SEE PLAN 101 PRE-ENGINEERED BUILDING AT CONCRETE FOOTING NO SCALE 3" CLR 3" CL R 1 5 6 7 3 2 4 KEYNOTES: 1.PRE-ENGINEERED BUILDING BY OTHERS 2.CONCRETE STEM WALL, SEE PLAN 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE SLAB ON GRADE, SEE PLAN 8.CONT 2x PT SOLE PLATE W/ SIMPSON STRONG BOLT 2 (ESR-3037) HILTI ANCHORS KWIK-BOLT TZ (ESR-1917) OR SIMILAR APPROVED PRODUCT, SEE SHEARWALL SCHEDULE FOR SIZE AND SPACING 9.WALL SHEATHING AS OCCURS, SEE PLAN 10.WOOD STUD WALL, SEE PLAN 1 3 2 7 5 10 9 8 4" MI N 3" CLR 3" CL R 6 5 4 107 PRE-ENGINEERED BUILDING AT CONCRETE FOUNDATION NO SCALE KEYNOTES: 1.PRE-ENGINEERED COLUMN, SEE PLAN 2.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3. CONCRETE STEM WALL BEYOND, CONT REINFORCEMENT TROUGH PIER (NOT SHOWN FOR CLARITY) 4.MINIMUM FOOTING DEPTH, SEE GSN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 6.CONCRETE FOOTING, SEE PLAN 7.18"Ø CONCRETE PIER W/ (8) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 8.CONCRETE GRADE BEAM, SEE PLAN 9.HAIRPIN AS OCCURS, SEE PLAN 10.CONCRETE SLAB ON GRADE, SEE PLAN 11.ANCHOR BOLTS W/ NUT AT BOTTOM 12.CENTERLINE OF STEEL COLUMN & FOOTING 104 PRE-ENGINEERED COLUMN AT CONCRETE FOOTING NO SCALE 3" CLR 3" CL R 5 3 10 7 30" MIN LAP 8 9 2 1 12 11 4 6 106 TYPICAL STEEL COLUMN AT FOUNDATION NO SCALE 1 2 3 5 1 KEYNOTES: 1.STEEL COLUMN, SEE PLAN 2.CONCRETE FOOTING, SEE PLAN 3.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 4.CONCRETE CLOSURE POUR, POUR AFTER DEAD LOADS ARE IN PLACE 5.CONCRETE SLAB ON GRADE, SEE PLAN 6.3 4" STEEL BASEPLATE W/ (4) 3 4"Ø ANCHOR BOLTS W/ 7" MIN EMBEDMENT 4 4 PLANA A 3" CLR 3" CL R 11 2" TYP 112" TY P TYP 1/4 6 112" TY P 108 PRE-ENGINEERED COLUMN AND WOOD POST AT CONCRETE FOOTING NO SCALE KEYNOTES: 1.PRE-ENGINEERED COLUMN (BEYOND), SEE PLAN 2.ANCHOR BOLTS W/ NUT AT BOTTOM 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING & CONCRETE STEM WALL BEYOND CONT REINFORCING THROUGH PIER (NOT SHOWN FOR CLARITY) 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE FOOTING, SEE PLAN 8.CONCRETE PIER (SEE PLAN FOR DIMENSIONS) W/ (10) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 9.CONCRETE SLAB ON GRADE, SEE PLAN 10.HAIRPIN AS OCCURS, SEE PLAN 11.WOOD POST, SEE PLAN 12.SIMPSON ABU66Z POST BASE W/ 5 8"Ø TITAN HD SCREW ANCHOR 3" CLR 3" CL R 7 6 310 1 2 8 9 4 5 KEYNOTES: 1.CONCRETE SLAB ON GRADE, SEE PLAN 2.CONCRETE GRADE BEAM, SEE PLAN 109 CONCRETE GRADE BEAM AT CONCRETE SLAB NO SCALE 2 1 3" CLR 3" CL R PER PLAN PE R PL A N KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ ANCHOR BOLTS PER SHEARWALL SCHEDULE 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE FOOTING, SEE PLAN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 6.EDGE NAILING, SEE SHEARWALL SCHEDULE 7.WALL SHEATHING AS OCCURS, SEE PLAN 3" CLR 3" CL R 7 6 5 1 2 4 3 111 WOOD STUD WALL AT FOUNDATION NO SCALE KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ O.145"Ø MIN SHOT PIN AT 16" O.C. 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE FOOTING, SEE PLAN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 3" CLR 3" CL R 5 1 2 4 3 110 WOOD STUD WALL AT FOUNDATION NO SCALE 12 11 4" MI N 112 WOOD STUD WALL AT FOUNDATION NO SCALE 3" CLR 3" CL R 8 10 7 9 6 1 2 5 4 3 KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ SIMPSON STRONG BOLT 2 (ESR-3037) HILTI ANCHORS KWIK-BOLT TZ (ESR-1917) OR SIMILAR APPROVED PRODUCT, SEE SHEARWALL SCHEDULE FOR SIZE AND SPACING 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.MINIMUM FOOTING DEPTH, SEE GSN 8.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 9.EDGE NAILING, SEE SHEARWALL SCHEDULE 10.WALL SHEATHING AS OCCURS, SEE PLAN 4" MI N PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 11 / 1 3 / 2 3 14 1 3 4 D VID B . P O R T E R L I C E N SED PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 St r u c t u r a l E n g i n e e r i n g fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 co n t a c t @ f r o s t s t r u c t u r a l . c o m S3.0 11/13/23 TH U N D E R B I R D B U I L D I N G TE T O N W E S T C O N S T R U C T I O N GT C DB P IF 2 3 - 4 1 1 S3 . 0 F O U N D A T I O N D E T A I L S TH O R N T O N , I D A H O . . . . . . . . . . . . . . . . . . . . . . KEYNOTES: 1.WOOD JOIST W/ (2) 16d NAILS, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.WALL SHEATHING AS OCCURS, SEE PLAN 5.EDGE NAILING, SEE SHEARWALL SCHEDULE 6.CONT RIM BOARD 7.BOUNDARY NAILING, SEE PLAN 8.A35 CLIP BETWEEN EVERYOTHER JOIST 9.FLOOR SHEATHING, SEE PLAN 10.PRE-ENGINEERED BUILDING 1 2 3 5 4 7 6 9 10 8 201 WOOD JOIST AT WOOD STUD WALL NO SCALE KEYNOTES: 1.WOOD JOIST, SEE PLAN 2.WOOD JOIST BLOCKING AT 24" O.C. W/ (2) 16d NAILS 3.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 4.WOOD STUD WALL, SEE PLAN 5.WALL SHEATHING AS OCCURS, SEE PLAN 6.EDGE NAILING, SEE SHEARWALL SCHEDULE 7.CONT RIM BOARD W/ A35 CLIP AT 32" O.C. 8.BOUNDARY NAILING, SEE PLAN 9.FLOOR SHEATHING, SEE PLAN 10.(4) 10d NAILS INTO EACH BLOCK 11.PRE-ENGINEERED BUILDING 202 WOOD JOIST AT WOOD STUD WALL NO SCALE 1 3 4 6 5 8 7 9 2 10 KEYNOTES: 1.WOOD JOIST W/ HANGER, SEE PLAN 2.WOOD BEAM, SEE PLAN 3.BOUNDARY NAILING, SEE PLAN 4.FLOOR SHEATHING, SEE PLAN 1 34 2 206 WOOD JOIST AT WOOD BEAM NO SCALE 11 KEYNOTES: 1.WOOD JOIST W/ (2) 16d NAILS, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.BOUNDARY NAILING, SEE PLAN 5.FLOOR SHEATHING, SEE PLAN 6.CONT RIM BOARD 7.WALL SHEATHING AS OCCURS, SEE PLAN 8.EDGE NAILING, SEE SHEARWALL SCHEDULE 1 2 3 4 6 5 203 WOOD JOIST AT WOOD STUD WALL NO SCALE 8 7 KEYNOTES: 1.WOOD JOIST, SEE PLAN 2.WOOD JOIST BLOCKING AT 24" O.C. W/ (2) 16d NAILS 3.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 4.WOOD STUD WALL, SEE PLAN 5.WALL SHEATHING AS OCCURS, SEE PLAN 6.EDGE NAILING, SEE SHEARWALL SCHEDULE 7.CONT RIM BOARD W/ A35 CLIP AT 32" O.C. 8.BOUNDARY NAILING, SEE PLAN 9.FLOOR SHEATHING, SEE PLAN 10.(4) 10d NAILS INTO EACH BLOCK 204 WOOD JOIST AT WOOD STUD WALL NO SCALE 1 3 4 6 5 8 7 9 2 10 205 WOOD JOIST AT WOOD BEAM NO SCALE KEYNOTES: 1.FLOOR SHEATHING, SEE PLAN 2.BOUNDARY NAILING, SEE PLAN 3.WOOD JOIST W/ HANGER, SEE PLAN 4.WOOD BEAM, SEE PLAN 3 4 21 3 207 WOOD BEAM AT STEEL COLUMN NO SCALE NOTE: A.SEE CORRESPONDING DETAILS FOR ADDITIONAL INFORMATION KEYNOTES: 1.WOOD BEAM, SEE PLAN 2.SIMPSON CCOQ COLUMN CAP 3.STEEL COLUMN, SEE PLAN 11 2 3 1/4 208 WOOD BEAM AT STEEL COLUMN NO SCALE KEYNOTES: 1.WOOD BEAM, SEE PLAN 2.STEEL COLUMN, SEE PLAN 3.SIMPSON ECCOQ COLUMN CAP 3 1/4 2 1 NOTE: A.SEE CORRESPONDING DETAILS FOR ADDITIONAL INFORMATION KEYNOTES: 1.WOOD JOIST, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.WALL SHEATHING AS OCCURS, SEE PLAN 5.EDGE NAILING, SEE SHEARWALL SCHEDULE 6.WOOD JOIST BLOCKING W/ (4) 16d NAILS BETWEEN EACH JOIST TO DBL TOP PLATE 7.FLOOR SHEATHING, SEE PLAN 8.BOUNDARY NAILING, SEE PLAN 209 WOOD JOIST AT WOOD STUD WALL NO SCALE 1 3 2 5 6 4 78 211 WOOD JOIST AT WOOD STUD WALL NO SCALE KEYNOTES: 1.WOOD JOIST W/ HANGER, SEE PLAN 2.CONT 13 4"x117 8" LVL LEDGER W/ (4) SDWS22500DB AT EACH STUD 3.FLOOR SHEATHING, SEE PLAN 4.WALL SHEATHING AS OCCURS, SEE PLAN 5.WOOD STUD WALL, SEE PLAN 6.BOUNDARY NAILING, SEE PLAN 7.SIMPSON H8 TIE AT EACH JOIST 1 3 4 6 5 7 2 210 WOOD JOIST AT WOOD STUD WALL NO SCALE KEYNOTES: 1.WOOD JOIST W/ HANGER, SEE PLAN 2.CONT 13 4"x117 8" LVL LEDGER W/ (4) SDWS22500DB AT EACH STUD 3.FLOOR SHEATHING, SEE PLAN 4.WALL SHEATHING AS OCCURS, SEE PLAN 5.WOOD STUD WALL, SEE PLAN 6.BOUNDARY NAILING, SEE PLAN 7.SIMPSON H8 TIE AT EACH JOIST 8.WOOD JOIST BLOCKING AT 24" O.C. W/ (2) 16d NAILS 9.(4) 10d NAILS INTO EACH BLOCK 1 3 4 6 5 7 2 8 9 PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 11 / 1 3 / 2 3 14 1 3 4 D VID B . P O R T E R L I C E N SED PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 St r u c t u r a l E n g i n e e r i n g fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 co n t a c t @ f r o s t s t r u c t u r a l . c o m S4.0 11/13/23 TH U N D E R B I R D B U I L D I N G TE T O N W E S T C O N S T R U C T I O N GT C DB P IF 2 3 - 4 1 1 FR A M I N G D E T A I L S TH O R N T O N , I D A H O . . . . . . . . . . . . . . . . . . . . . . KEYNOTES: 1.IF FLOOR FRAMING CONFLICTS WITH THE WALL GIRT, THE WALL GIRT MAY BE OMITTED. 301 FRONT POP-OUT FRAMING ELEVATION NO SCALE302SIDE POP-OUT FRAMING ELEVATION NO SCALE HS S 4 x 4 x 5 / 1 6 HS S 4 x 4 x 5 / 1 6 8"x2.5"x12 GA. C-GIRT 8"x2.5"x12 GA. C-GIRT 8"x2.5"x12 GA. C-GIRT 8"x2.5"x12 GA. C-GIRT HS S 4 x 4 x 5 / 1 6 8"x2.5"x12 GA. C-GIRT HS S 4 x 4 x 5 / 1 6 8"x2.5"x12 GA. C-GIRT 8"x2.5"x12 GA. C-GIRT 8"x2.5"x12 GA. C-GIRT 8"x2.5"x12 GA. C-GIRT (3 ) G I R T S E Q U A L L Y S P A C E D (4 ) G I R T S E Q U A L L Y S P A C E D 8"x2.5"x12 GA. C-GIRT 8"x2.5"x12 GA. C-GIRT 1 306 WOOD STUD FRAMING AT LIGHT GAUGE GIRT NO SCALE KEYNOTES: 1.2x8 STUDS AT 16" O.C. 2.CONT 2x8 PLATE W/ #12 SMS SCREW AT 8" O.C. 3.7 16" WALL SHEATHING W/ 8d NAILS AT 6" O.C. AT EDGES (BLOCKED ALL EDGES) AND 12" O.C. IN FIELD 4.HORIZONTAL WALL GIRT, SEE ELEVATION 1 3 4 2 305 LIGHT GAUGE GIRT AT LIGHT GAUGE GIRT NO SCALE KEYNOTES: 1.HORIZONTAL WALL GIRT, SEE ELEVATION 2.14" TIE PLATE W/ (2) 12"Ø THROUGH BOLTS INTO EACH GIRT 304 LIGHT GAUGE GIRT AT HHS COLUMN NO SCALE KEYNOTES: 1.HSS STEEL COLUMN, SEE ELEVATION 2.L5x5x14"x4" W/ (2) 12"Ø THROUGH BOLTS 3.HORIZONTAL WALL GIRT, SEE ELEVATION 303 HSS COLUMN AT PEMB STEEL COLUMN NO SCALE KEYNOTES: 1.PEMB STEEL COLUMN 2.L3x3x14" TIE ANGLE AT 4'-0" O.C. (MAX) AND (1) WITHIN 6" OF TOP AND BOTTOM OF PEMB COLUMN 3.HSS STEEL COLUMN, SEE ELEVATION 1 2 1 2 1 2 1 3/16 3/16 3 TYP 3/16 2 1 3 PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 11 / 1 3 / 2 3 14 1 3 4 D VID B . P O R T E R L I C E N SED PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 St r u c t u r a l E n g i n e e r i n g fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 co n t a c t @ f r o s t s t r u c t u r a l . c o m S5.0 11/13/23 TH U N D E R B I R D B U I L D I N G TE T O N W E S T C O N S T R U C T I O N GT C DB P IF 2 3 - 4 1 1 PO P - O U T F R A M I N G E L E V A T I O N S TH O R N T O N , I D A H O . . . . . . . . . . . . . . . . . . . . . .