HomeMy WebLinkAboutCODE SHEET & FLOOR PLANS - 23-00865 - 4821 Thunderbird Loop - Heaven's Best - RemodelREVISIONS SUBMITTAL REVIEW PROCESS CODE INFORMATION GENERAL BUILDING NOTESGENERAL NOTES: APPUCABLE CODES z BUILDING DESCRIPTION1. 1. 5 (REXBURG, IDAHO)CLIMATE ZONE: SEE STRUCTURAL DRAWINGS FOR SEISMIC DESIGN CATEGORY, RISK CATEGORY, WIND LOAD, EXPOSURES, ETC.2. PROVIDEDBUILDING CRITERIA CODE REFERENCECODE REQUIREMENT 3.IBC SECTION 304, 311OCCUPANCY GROUP / USE1. BUILDING SQUARE FOOTAGE TYPE OF CONSTRUCTION TYPE28 TABLE 5032.BUILDING FOOTPRINT: 13,300 SF 4.ALL EXPOSED CONCRETE SHALL HAVE A RUBBED SMOOTH SAND PLASTER FINISH MAX. BUILDING AREA PER STORY = 13,300 SF IBC SECTION 506.2, 506.3, 5083.ALLOWABLE AREA ALLOWABLE AREA - 23,000 S.F. PER FLOOR (GROUP BORS2)(SEE CALC.) 5. BUILDNG HEGHT MAX. BULDING HEIGHT = 36 IBC TABLE 503 & SECTION 504.24.SECOND FLOOR STORAGE 1,005 SF STORAGE BAYS 3,795 SF 6.IBC TABLE 503 & SECTION 504.25.NUMBER OF STORIES 2 STORY PROMDED (SECOND STORY - OFFICES AND STORAGE) TENANT #1 6.NUMBER OF OCCUPANTS,28 OCCUPANT LOAD (SEE OCCUPANCY CALCS.) IBC TABLE 1004.1.1CONTRACTOR TO PROVIDE WOOD BACKING FOR ALL ITEMS ATTACHED TO WALLS.7.COMMUNITYstsUSE TOTAL SQUARE FOOTAGE 8,155 SF7.ACCESSIBUTY SEE IBC CHAPTER 11 FOR REQUREMENTS ALL DOOR LOCATIONS COMPLIANT IBC CHAPTER 11"PROVIDE” SHALL REPRESENT THE REQUIRMENT TO SUPPLY AND INSTALL THE ITEM INDICATED.8. 8.FIRE SPRINKIFRS NOT REQURFD AREA SEPARATION WAIL PROWOED IBC SECTION 903 9.AREA SEPARATION IBC TABLE 508.49. MXED USE B, S2), NON-SEPARATED USES (GROUP A3 WORST CASE) 3 HOUR WAL (EXCESS Of REQUIRED) OCCUPANCY CALCS.MEANS OF EGRESS 10. MIXED USE OCCUPANCY, NON-SEPARATED USES (SEE IBC SECTION 508)IBC SECTION 100811.OCCUPANCY GROUP LOAD FACTOR AREA OCCUPANTS USE SPECIAL INSPECTION REQUIREMENTS LESS THAN 1/2DWGONA____ _ LESS W 1/2 OF MW, DWCONAL OF AREA SERVED 1,150 SF 8 OFFICE12. SEE SHEET A3.8 FOR WALL TYPES DETAILS. 1,200 SF 8 OFFICE 13. VERIFY EXACT ROUGH OPENING DIMENSIONS FOR ALL BUILT IN ITEMS 10 STORAGE4,800 SF 1.SEE STRUCTURAL DRAWINGS FOR DESIGN LOADS AND SPECIAL INSPECTION REQUIREMENTS.1,105 SF 2 STORAGE COORDINATE DUCT INSTALLATION W/ ELECTRICAL AND PLUMBING INSTALLATION14.STRUCTURAL ELEMENT FIRE RESISTANCE (F R.) RATING TESTED DESIGN # CODE REFERENCE2.SEE MECHANICAL DRAWINGS FOR SPECIAL INSPECTION REQUIREMENTS TOTAL OCCUPANTS 28 OCCUPANTS 3.SEE ELECTRICAL DRAWINGS FOR SPECIAL INSPECTION REQUIREMENTS15.LUIBC TABLE 601, TABLE 6024.SPECIAL INSPECTION IS REQUIRED FOR FIREPROOFING, FIRE PENETRATION AND JOINTS, SMOKE CONTROL IBC TABLE 601, TABLE 602 IBC TABLE 601, TABLE 60216. 17. ALL GYPSUM BOARD EDGES TO BE SQUARE EDGE. 18. MINIMUM PLUMBING REQUIREMENTS CODE REFERENCECODE REQUIREMENT PROVIDED 19. I. ISECTION 2902 & TABLE 2902.1 » 20.SECIION2902 & TABLE 2902.1 SECTION 2902 & TABLE 2902.1 AREA INCREASE FOR FRONTAGE O— 1. SEE PLANS ON SHEETS A0.1 - A0.5 FOR EXITING AND FIRE WALLS U) 1” GAP SEPARATING STUDSA JX X 8— — I-0" MN1UL U395 3-HOUR HANDRAIL PER CODE ABREVIATIONS SYMBOLS T" £MH TTP. FLOOR JOIST CENTER LINE DESIGNATION r BFEAK LINE DESIGNATION INTERIOR ELEYATION KETE1 4 8AGRID LINE l’-O"1.1/2”1.1/2”EDGES SHALL HAVE A HIDDEN LINE MINIMUM RADIUS OF 0.01”MHWINDOU / STOREFRONT REFERENCE NOSING: FOOTING LINE (3) 2" X 12“ PARALLAM STRINGERS < BUILDING SECTION C 1/2" TTPE "X" GTP.J () CONCRETE SLAB < 21 1 6—=--===PLTUOODUALL SECTION LU GYPSUM BOARD IYXXUSCATEDFTPINSULATION (LOOSE OR BATT) DETAIL SECTION UALL IN PLAN DETAIL FEFEFENCE (VERIFY THAT HANDRAIL IS PER CODE)CONCFETEO o m CONCFETE BLOCK I. 7//7/BRICK 101 III III IIII9 RIGID INSULATION CENSEDUNNDOU CONST/DENO NOTE DESIGNATION v32 2 |||"EARTH C) OrUALL TYPE DESINATIONW1 838888GPANLLAR FILL Or UTA OFFICE 101 ROOM NAME AND NUMBER A0.1 M5508E 2PROVDED 2 PROVDED 1 PROVDED ALL WINDOW COVERINGS. SECURITY SYSTEM/ELECT. KEY CARD ACCESS AND FF&E TO BE PROVIDED AND INSTALLED BY OWNER. APPLIANCES TO BE PROVIDED BY OWNER AND INSTALLED BY THE G.C ID IN ALL NEW CONSTRUCTION AND MODIFICATIONS TO ANY EXISTING CONSTRUCTION OF SYSTEMS RELATED TO ANY CONSTRUCTION MUST CONFORM TO THE APPROPRIATE CONSTRUCTION, ENERGY, MECHANICAL, ELECTRICAL, STRUCTURAL, CIVIL OR ANY OTHER BUILDING RELATED STATE OR LOCAL CODES THAT ARE ADOPTED AND ENFORCEABLE. FEB 2024 IDAHO MXED USE OCCUPANCY, NON-SEPARATED USES (SEE OCCUPANCY CALCS.) PRMARY USE / WORST CASE: OCCUPANCY GROUP A3 / PRACTICE FD GUARDRAIL TO BE MINIMUM HEIGHT OF 36" AND HAVE NO NET OPENINGS EXCEEDING 4" ON VERTICAL BALUSTERS SEE ARCH. FOR BRACKET (FASTEN TO WALL AS PER MFGR’S RECOMMENDATION) (2) ROWS OF 2X4 STUDS • 16 0.c. STAGGERED 8” HANGER IF REQ. SEE STRUCTURAL 1ST LEVEL SQUARE FOOTAGE 2ND LEVEL SQUARE FOOTAGE 1/150 1/150 1/500 1/500 5,950 SF 2,205 SF 3/4" MIN TO 1 1/4" MAX. IBC SECTION 1005.3 IBC TABLE 1006.3.2 IBC SECTION 1015.2.1 1,150 SF 1,200 SF C a MAIN FLOOR OFFICE SECOND FLOOR OFFICE or o (2) LAYERS 5/8” TYPE C, BOTH SIDES GROUP B (MAIN LEVEL) GROUP B (SECOND LEVEL) GROUP S2 (MAIN LEVEL) GROUP S2 (SECOND LEVEL) THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED BUILDING PERMITS, SCHEDULING INSPECTIONS AND PROVIDING MATERIALS AND WORKMANSHIP IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE INTERNATIONAL BUILDING CODE AND APPLICABLE REGULATIONS ENFORCED BY LOCAL AND STATE AGENCIES. SPRAYED CELLULOSE FIBER, COMPLETELY FILL CAMTY. MIN. DRY DENSITY TO BE 4.3 LBS/C.F. EXTEND SHAFT WALLS, STAIR WALLS, AND CORRIDOR WALLS TO BOTTOM OF DECK. FIRE TAPE ONLY ABOVE FINISHED AREAS co LU CO INCL INFO INS INT JT LAM LAV MAX MECH MFR MTL MIN MIR MISC NO OC OPP PEN PL PT PSF PSI PVC PWD QTY RA RE REINF REP REQ RM SA SCH SEC SHT SHTG SIM SPEC SQ SS STD STL STRUC SYM SV TEN T&G TEMP THK THRU TYP UL UNFIN UON VAR VERT VIF VIN W/ W/O WC WD 2. 3. I C o 0 PROVIDE FIRE SAFING AND SEALANTS PER MFR'S INSTRUCTIONS AT PENETRATION OF ALL WALLS REQUIRING FIRE RESISTANCE AS INDICATED. FIRE RESISTANCE OF FIRE SAFING AND SEALANTS SHALL MEET THAT OF THE WALL IN WHICH PENETRATION OCCURS. THE ARCHITECT & OWNER ASSUME NO RESPONSIBILITY FOR ANY UNFORSEEN EXISTING CONDITIONS, ANY CONTRACTOR'S WORK, WORKMEN, SUBCONTRACTORS OR ANY PERSON CONNECTED WITH ANY CONSTRUCTION ON THIS WORK. ANY AND ALL QUESTIONS REGARDING THESE DRAWINGS SHALL BE DIRECTED TO THE ARCHITECT OR OWNER'S REPRESENTATIVE. BLOCKING BETWEEN STRINGERS A NEW SINGLE-STORY MANUFACTURED STEEL BUILDING WITH RETAIL AND OFFICE SPACE FOR VENTURE BUILDERS, TENANT 1 () Z CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS ON SITE AND REPORT ANY DISCREPANCIES AND/OR UNFORSEEN ADVERSE CONDITIONS REQUIRING DRAWINGS AND/OR CONSTRUCTION MODIFICATION IN WRITING TO THE ARCHITECT'S AND CONSTRUCTION MANAGER'S OFFICE. ALL ITEMS THAT PENETRATE FIRE RATED CEILINGS (LIGHTS & ETC.) SHALL BE TENTED WITH 5/8” TYPE C GYPSUM BOARD. ? o UOOD (ROUGH CONTNUOUS MEMBER) C t MAINTAIN FIRE PROTECTION SYSTEM DURING CONSTRUCTION AND TAKE ALL PRECAUTIONS TO PROTECT WORKMEN AND STRUCTURES. PER IBC SECTION 107.3.4.2 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND BEEN FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING. APPLICABLE CODES: 2018 IBC, 2015 IMC, 2017 NEC, 2018 UPC, 2015 IFC, 2015 IFGC, 2018 IECC, 2009 ICC/ANSI A117.1. 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES, ORDINANCES RULES, REGULATIONS, ORDERS AND OTHER LEGAL REQUIREMENTS OF ADMINISTRATIVE AUTHORITIES HAVING JURISDICTION. 3 STORES ALLOWED + 1 STORY FOR INCREASE FOR FIRE SPRINKLERS CO Q a FIRE RATED THROUGH PENETRATIONS MUST BE TREATED ACCORDING TO EACH MANUFACTURER’S SPECIFICATION FOR TYPE AND SIZE OF MATERIAL AND THE ANNULAR SPACE REQUIREMENTS OF EACH PENETRATION. GENERAL CONTRACTOR AND FRAMING SUB-CONTRACTOR TO ADJUST FLOOR AND ROOF FRAMING MEMBERS TO ALLOW FOR PLUMBING FIXTURE TRAPS, ROOF HATCHES, ETC. PER IBC SECTION 107.3.4.1 HARRIS ARCHITECTURE, THE REGISTERED DESIGN PROFESSIONAL IN CHARGE SHALL BE RESPONSIBLE FOR REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS PREPARED BY OTHERS, INCLUDING PHASED AND DEFERRED SUBMITTAL ITEMS, FOR COMPATIBILITY WITH THE DESIGN OF THE BUILDING. 1.5"x1.5 STEEL TUBE (SEE FINISH SCHEDULE / FLOOR PLANS FOR FINISH) (2) LAYERS 4‘-0" WIDE, 5/8 GWB APPLIED VERTICALLY, FIRST LAYER ATTACHED MTH 6 CEMENT COATED NAILS SPACED AT 10° O.C. & SECOND LAYER ATTACHED WTH 8d NAILS SPACED 7" O.C. VERTICAL JOINTS BETWEEN LAYERS TO BE STAGGERED. FIRE SPRINKLER STANDPIPES, VALVE GAUGES, ETC. MUST NOT ENCROACH INTO REQUIRED STAIRWAY WIDTH / RADIUS. LU S O LU I. DETAIL No. Al ■ SHEET UHERE DRAIN 55‘-0 ALLOWED+ 20 FEET FOR FIRE SPRINKLERS (N/A) = 75-0* 2" X 4" REDWOOD OR TREATED PLATE BLOCKING BETWEEN STRINGERS WOOD BLOCKING (INTERRUPTED MEMBER) 1 2 & O 13,300 SF • (SEE OCCUPANCY CALC.) 2 L. O LI Q. LL IT C C. co Q LU C Z. D I FIN FLR FOS FRP FRTW FT GA GALV GC GL LAM GWB, GYP BD GYP H HDWR HM HOR HR HT, HGT HVAC 1 - SECTION No. Al • SHEET UHERE DRAUN SIRUCTURAL FRANE_ BEARING WNIS - EXTERIOR BEARING WAIS - NTERIOR NON-BEARING WALLS - EXTERIOR NON-BEARING WALLS - NTERIOR VERTICAL SHAFTS AB A/C AC ACT ADD ADJ AFF AHJ ALUM ALT APPROV APPROX ARCH AUTO BD BETW BLDG BOT CAB CB CLG CLR CTR CMU COL CONC CONST CONT CONTR COORD CORR CT DBL DEMO DIA DIM DN DR DTL DWG EA ELEV, EL ELEC EQ EQUIP EXIST, EX EXT EWC FA FEC FFEC 1 - SECTION No. Al ■ SHEET UHERE DRAIN ANCHOR BOLT AIR CONDITIONING ACOUSTIC(AL) ACOUSTICAL CEILING TILE ADDENDUM ADJACENT ABOVE FINISHED FLOOR AUTHORITY HAVING JURISDICTION ALUMINUM ALTERNATE, ALTERNATIVE APPROVE(D), APPROVAL APPROXIMATE(LY) ARCHITECT(URAL) AUTOMATIC BOARD BETWEEN BUILDING BOTTOM CABINET CERAMIC BASE CEILING CLEAR(ANCE) CENTER CONCRETE MASONRY UNIT COLUMN CONCRETE CONSTRUCTION CONTINUE, CONTINUOUS CONTRACT(OR) COORDINATE, COORDINATOR CORRIDOR CERAMIC TILE DOUBLE DEMOLISH, DEMOLITION DIAMETER DIMENSION DOWN DOOR DETAIL DRAWING EACH ELEVATION ELECTRICAL EQUAL EQUIPMENT EXISTING EXTERNAL ELECTRIC WATER COOLER FRESH AIR FIRE EXTINGUISHER CABINET FIXTURES/ FURNISHINGS/ EQUIPMENT CONTRACTOR FINISHED FLOOR FACE OF STUD FIBER REINFORCED PANEL FIRE RETARDANT TREATED WOOD FOOT, FEET GAUGE GALVANIZED GENERAL CONTRACTOR GLU LAMINATED BEAM GYPSUM WALL BOARD GYPSUM HIGH HARDWARE HOLLOW METAL HORIZONTAL HOUR HEIGHT HEATING/ VENTILATION/ AIR CONDITIONING INTERIOR DESIGNER INCH(ES) O—i Q. DOOR DESIGNATION t - DOOR No. NUMBER OF EXITS TRMVL DISTANCE DEAD END CORRIDOR CORRIDOR MOTH SIZE OF DOORS EGRESS MDTH PER OCCUPANT COMMON PATH OF TRAVEL TwO EXIT SEPARATION — 2 LU — LU > o Q. Q. 3 CODE REFERENCE IBC TABLE 1006.3.1 IBC TABLE 1017 J IBC SECTION 1020.4 IBC TABLE 1020.2 REXBURG, IDAHO_____________________ PARTIAL SECOND FLOOR OFFICE AND STORAGE 1 . DETAIL No. Al = SHEET UHEFE DRAIN IBC TABLE 601, 602, SECTION 403.3.1 IBC TABLE 601, TABLE 602 1. 2. 3. 4. 5. 6. 7. 8. O s § e T O Q d L E u. o s U Q. O Q. Q. u T __ 5. 6. 7. 8. — 2 < 2 LU § LU Z < 81 g co LU © □ CODE REQUIREMENT 2 REQUIRED _ _ 200 FEET WX. (SPRINKLERED: 250FEET) 20 FEET MAX (SPRINKIERED: 50 FEET) 44 INCH MN._____________ 32 INCH CLEAR WIDTH MN.____ .2x28= 5.6 INCHES75 FEET MAX. 5 8 O Z Q 2 () ANDRAIL DETAIL sAII MS ■ LU E 2 2 2 iL C) d C S C DRAWN BY LCN f 2 2 8 d2 o 2 i LI C 0 2LL § PROVIDED ■ . ■ ■ ■ MORE THAN 2 EXITS (PER LEVEL)PROVDED LESS THAN 200 FEET LESS THAN 20 FEET ________ 44 INCHES PROVDED _______ ALL D00RS COMPLIANT 72 ICC PROMDED LESS THAN 75 FEET =28/2=14EAW/F=2REQ‘D - 28/2 = 14 EA. M/F= 1M/1F REO’D = 28/100 = _ NON-RATED____________ NON-RATED NON-RATED NON-RATED NON-RATED 1 HOUR RATED (LESS THAN 4-SIORY)NON-RATED NON-RATED ___ NON-RATED Z o me E < 2 e O I Z DESIN OCCUPANCY - 28 OCX. BUSMESS USE / STORAGE WATER CLOSETS UVORATORIES DRINKING FOUNTAINS C. d Q. Q. O ( O Z I O u () LU I GTYPSTAIR DETAIL CORRIDOR WALLS FLOOR STRUCTURE 9. ROOF SIRUCTURE IBC SECIION 713.4_______ IBC TABLE 1020.1 IBC TABLE 601, TABLE 602IBC TABLE 601, TABLE 602 INCLUDE(D),(ING) INFORMATION INSULATE, INSULATION INTERIOR JOINT LAMINATE LAVATORY MAXIMUM MECHANICAL MANUFACTURER METAL MINIMUM MIRROR(ED) MISCELLANEOUS NUMBER ON CENTER OPPOSITE PENETRATION(S) PLASTIC LAMINATE PAINT(ED) POUNDS PER SQ FT POUNDS PER SQ IN POLMINYL CHLORIDE PLYWOOD QUANTITY RETURN AIR REFERENCE, REFER TO REINFORCE(D), (ING), (MENT) REPRESENTATIVE REQUIRE(D),(MENT) ROOM SUPPLY AIR SCHEDULE SECTION SHEET SHEATHING SIMILAR SPECIFICATION(S) SQUARE STAINLESS STEEL STANDARD STEEL STRUCTURAL SYMMETRIC(AL) SHEET VINYL TENANT TONGUE AND GROOVE TEMPERATURE THICK(NESS) THROUGH TYPICAL UNDERWRITERS LABORATORY UNFINISHED UNLESS OTHERWISE NOTED VARIABLE, VARIES VERTICAL VERIFY IN FIELD VINYL WITH WITHOUT WATER CLOSET WOOD 8 uj Q. 2 ( TL. O 3 I 4,.2 ? Z. LL () 2 O O 7 E Q. s or □ F o E s X Q o s C LI § Z O O LL ( D Q O Q LL O D O 2 & Q uu 00 § e 5 C t O 2 1. 2. 3. 4. 3HR AREA SEPARATION WALL "WxTTT-------------------- Z 2 LL Q ui O & LL 0 u. O 2 Z LI 2 n.