Loading...
HomeMy WebLinkAboutINFRASTRUCTURE Rev 2 7.18.23 - 23-00085 - Founders Square Phase 3 - Plat-Reviewed-ApprovedAuthor Name Author Email Author Phone No.: Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314 Joel Gray Joel.Gray@rexburg.org 208-372-2331 Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Todd Smith Todd.Smith@rexburg.org 208-372-2181 Katie Saurey Katie.Saurey@rexburg.org 208-372-2167 Description : Founder's Square Phase 3Address : Sunrise DriveRecord Type : PlatDocument Filename : INFRASTRUCTURE Rev 2 7.18.23 - 23-00085 - Founders Square Phase 3 - Plat.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 23-00085 Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments 1 Stamp Todd Smith : Broadband Open 1 Approved - Broadband Inspector 13 Stamp Todd Smith : Broadband Open 13 Approved - Broadband Inspector 1 Stamp Stan Crittenden : Fire Open 1 Approved - Fire Dept 1 Stamp Katie Saurey : P&Z Open 1 Plan Received 3 Stamp Kyle Baldwin : P&Z Open 3 Approved - Planning and Zoning 1 Stamp Joel Gray : PW Open 1 Approved - Public Works Plat Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) Project Name and Address EXBURGR Plot Scale Date Description Sheet Firm Name and Address C I T Y O F America's Family Community CITY OF R EXBURG, I D A HO E S TA BLISH E D I 8 8 3 CITY OF REXBURG BROADBAND DETAILS BROADBAND NOTES BROADBAND 4/4/2022 1 = 2 Scale AS NOTED 14 GENERAL NOTES: 1.DISTRIBUTION FIBER SHALL BE LOCATED WITHIN THE COMMUNICATION TRENCH AS SHOWN IN THE CITY OF REXBURG'S ENGINNERING STANDARDS.a. UNLESS OTHERWISE DETERMINED, FIBER CONDUIT MUST BE LAID ON BOTH SIDES OF THE STREET.DISTRIBUTION FIBER SHALL BE DIRECT BURY 4-WAY 18MM/14MM TRACEABLE DURA-LINE FUTUREPATH (OR EQUIVALENT).2. ALL DISTRIBUTION FIBER CONDUIT SHALL HAVE A LOCATE WIRE GROUNDED AT EACH HANDHOLE.3. MINIMUM DEPTH OF COVER OVER CONDUIT SHALL BE 36", UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 4. DISTRIBUTION BOXES AND/OR HANDHOLES SHALL BE PLACED:a.SINGLE FAMILY RESIDENCES: A 14" X 19" X 12" CARSON HDPE (OR EQUIVALENT) HANDHOLE SHALL BE PLACED IN BETWEEN SINGLE FAMILYRESIDENCES ON THE LOT LINE WITH THE INTENT TO SERVE TWO SINGLE FAMILY HOMES FROM EACH PULL BOX. b.SUBDIVISIONS: FOR MULTI-HOME DEVELOPMENTS, A 24" X 36" X 24" DURALITE ()OR EQUIVALENT) HANDHOLE SHALL BE PLACED AT THE CORNEROF THE EASEMENT.c.MULTIFAMILY RESIDENCES: i.DUPLEXES & FOURPLEXES: 24" X 36" X 24" DURALITE T22 (OR EQUIVALENT) HANDHOLE SHALL BE PLACED IN BETWEEN BUILDINGS WITH THEINTENT TO SERVE ALL THE RESIDENCES FROM THE HANDHOLE. FOR FOURPLEXES AND APARTMENTS THE BUILDER IS ENCOURAGED TO PLAN OUTTHE PATH OF THE DROP(S) AND INCLUDE A 2" PVC STUB-OUT FROM THE BUILDING TO A POINT THAT IS PAST SIDEWALKS, PATIOS, DRIVEWAYS,AND OTHER HARD SURFACES SO THE DROP CAN BE INSTALLED WITHOUT BORING OR CUTTING CONCRETE.ii.TOWN HOMES & 4 OR MORE APARTMENT BUILDINGS: A 24” X 36” X 24” T22 DURALITE (OR EQUIVALENT) HANDHOLE SHALL BE PLACED AT THECORNER OF THE LOT WHERE PRACTICAL. 5. A 10' X 10' EASEMENT SHALL BE GRANTED TO THE CITY FOR ADDITIONAL FIBER INFRASTRUCTURE IF NEEDED. (HANDHOLES MAY BE WITHIN THIS AREA)6. FIBER CONDUIT SHALL BE STUBBED-OUT TO THE EDGES OF DEVELOPING PROPERTY TO ALLOW FOR FUTURE FIBER OPTIC SERVICE TO ADJACENTPROPERTY AND TO PROVIDE PATHWAYS TO THE OVERALL SYSTEM.a. ALL EMPTY CONDUITS SHOULD BE PLUGGED AS CONSTRUCTION TAKES PLACE. b. INDIVIDUAL HOUSE/BUSINESS FIBER SERVICE LINES SHALL BE LABELED AND STUBBED-OUT TO LOTS ADJACENT TO NEW STREETS TO ELIMINATETHE NEED FOR FUTURE EXCAVATION WORK IN NEW STREETS.6. DEVELOPERS SHALL BE RESPONSIBLE FOR INSTALLATION AND PURCHASE OF CONDUIT, DISTRIBUTION BOXES AND HANDHOLES FOR DIRECT BURY 4-WAY DURALINE 18MM/14MM TRACEABLE FUTUREPATH (OR EQUIVALENT FOR THE PROPOSED NEW DEVELOPMENT.7. ACCEPTANCE OF THE FIBER CONDUIT ARE BASED IN THE FOLLOWING CRITERIA:a. BEDDING AND BACKFILLING OF TRENCHES SHALL BE CONSTRUCTED IN ACCORDANCE WITH CURRENT CITY STANDARDS OR OTHERWISE SPECIFIEDBY THE CITY ENGINEER.b. PERFORM ALL TESTING IN THE PRESENCE OF THE CITY ENGINEER OR HIS ASSIGNED AGENT. PLACEHOLDER FOR TESTING AND INSPECTION CHECKLIST ITEMS. c. A SIGNED "LETTER OF ACCEPTANCE" FROM THE CITY WILL BE REQUIRED PRIOR TO FINAL SURFACE RECONSTRUCTION. (I.E. :PAVING, LANDSCAPING, ETC.).8. THE DEVELOPER WILL CONSTRUCT, THE CITY WILL OWN, AND THE CITY'S THIRD-PARTY NETWORK ADMINISTER WILL OPERATE AND MAINTAIN, THEFACILITIES WITHIN THE EASEMENTS OR RIGHTS-OF-WAY. GRADE TYPICAL 14" X 19" X 12" CARSON HDPE, OR 24" X 36" X 24" T22 DURALITE HANDHOLE, OR EQUIVALENT GROUND ROD - ALL SPLICINGLOCATIONS - GROUND FOSC AND TRACE 4" GRAVEL FILL AT HANDHOLE BASE 4-WAY 18MM/14MM TRACEABLEDURA-LINE FUTUREPATH OR EQUIVALENTFOR STANDARD CONDUIT STUB INTOHANDHOLE WITH LARGE RADIUS BENDS TYPICAL HANDHOLE INSTALL NOT TO SCALE HANDHOLE ASSEMBLYSIZES (BOX AND COVER) DESCRIPTION SIZE (LxWxH) CARSON HDPE 14"X19"X14" DURALIGHTT22 24"x36"x24" TYPICAL LID DETAILS NOT TO SCALE TYPICAL HANDHOLE INSTALLATION NOT TO SCALE W H 6"4" W HANDHOLE LID EVENWITH GROUND LEVEL GROUND LEVEL INSTALL 38" CRUSHED ROCK OREQUAL. EXTEND ROCK A MIN.OF 6" BEYOND WALLS XXX FIBER HH - 3 & HH - 4 XXX FIBER XX X F I B E R XX X F I B E R HH - 1 & HH - 2 3/8"STAINLESSHEX BOLT "XXX" FIBERNAME PLATE 38" OR 12" STAINLESS HEX BOLT *HANDHOLES SHALL BE NEW BASIS PRODUCTS OR EQUAL ALTERNATE AS APPROVED BY CITY ENGINEER Project Name and Address EXBURGR Plot Scale Date Description Sheet Firm Name and Address C I T Y O F America's Family Community CITY OF R EXBURG, I D A HO E S TA BLISH E D I 8 8 3 CITY OF REXBURG BROADBAND DETAILS BOX AND COVER DETAILS BROADBAND BOX 4/4/2022 1 = 2 Scale AS NOTED 15 JOINT UTILITY 4-WAY... CONDUIT OR AS SPECIFIED FIELD BEND CONDUIT FOR HANDHOLEENTRY TRENCH PATHWAY TO HANDHOLE LOCATION JOINT TRENCHSHELF 4 WAYCONDUIT OR AS SPECIFIED FIELD BENDCONDUIT FOR HANDHOLE ENTRY NOTE:INSTALLATION CONTRACTOR TO FOLLOWMANUFACTURE'S SPECIFICATIONS FOR CONDUIT AND HANDHOLE INSTALLATION. SEE MANUFACTURERS SPECIFICATIONS FOR MINIMUM CONDUIT BENDING RADIUS. Project Name and Address EXBURGR Plot Scale Date Description Sheet Firm Name and Address C I T Y O F America's Family Community CITY OF R EXBURG, I D A HO E S TA BLISH E D I 8 8 3 CITY OF REXBURG BROADBAND DETAILS ENTRY AND TRENCH DETAILS DETAILS 4/4/2022 1 = 2 Scale AS NOTED 16