HomeMy WebLinkAboutUPDATED PLANS - 23-00937 - Madison Health Surgery Center - RemodelAuthor Name Author Email Author Phone No.: Don Allen Don.Allen@rexburg.org 208-372-2174 Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : Madison Health Surgery Center - Mechanical Address : 381 E 4th N #200 Application Type : Document Filename : Madisonhealth Surgery Center HVAC Remodel Drawings.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments M1.0 Free Text Alex Owens : Electrical Open 1 Please provide specs of new equipment and duct detectors. All electrical work must comply with 2017 NEC. # 23-00937 Commercial - Remodel Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 12.29.2023 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) Please see the RTU and Duct Detector Product Data in this pdf 1/4"=1'-0" PARTIAL HVAC DEMO PLAN SCALE: EXISTING RTU-2 TO TO BE REMOVED AND REPLACED WITH NEW HALL CLEAN UTIL. / STERILE O.R.#1 O.R.#2 BREAK ROOM HALL HALL VEST. VEST. DSSG. T.R. RECOVERY ROOM PREP. SOILED HOLDING RECIEVING STOR. PATIENT EXIT OFFICE CONSULT PREP T.R.REC'P BUSINESS OFFICE WAITING STOR. W.LKR ROOM T.R. FIRE RISER T.R. M.LKR ROOM PREP HALL MECH. CUST. MED GAS ANTH. ROOM SOILED EXISTING RTU-1 TO TO BE REMOVED AND REPLACED WITH NEW EXISTING RETURN AIR EXISTING RETURN AIR EXISTING RETURN AIR EX I S T I N G R E T U R N A I R EX I S T I N G R E T U R N A I R EX I S T I N G R E T U R N A I R EXISTING SUPPLY AIR EXISTING SUPPLY AIR EXISTING SUPPLY AIR EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EXISTING SUPPLY AIR EXISTING SUPPLY AIR EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EXISTING SUPPLY AIR EXISTING SUPPLY AIR DEMO EXISTING DUCT WORK AS INDICATED. CAP AND SEAL PENETRATION AT EXISTING TO REMAIN (TYP.) EX I S T I N G R E T U R N A I R DEMO EXISTING DUCT WORK AS INDICATED. CAP AND SEAL PENETRATION AT EXISTING TO REMAIN (TYP.) DEMO DEMO DEMOEXISTING SUPPLY AIR CA P / S E A L EX I S T I N G EX EF EX EF150 CFM 200 CFM MECHANICAL LEGEND SYMBOL DUCTWORK DESCRIPTION DUCTWORK BREAK DUCTWORK OR PIPING RISE CONCENTRIC SQUARE TO ROUND TRANSITION MOTORIZED DAMPERM MANUAL VOLUME DAMPER SPIN-IN FITTING W/ AIR EXTRACTOR AND HAND DAMPERair flow HIGH EFFICIENCY FITTING W/ HAND DAMPERair flow SWITCH THERMOSTATT COMBINATION SMOKE/FIRE DAMPER FIRE DAMPER SUPPLY DIFFUSER RETURN GRILLE EXHAUST GRILLE FLEXIBLE DUCTWORK GENERAL NOTES: 1.VERIFY ALL PROJECT SITE DIMENSIONS AND CONDITIONS PRIOR TO COMMENCEMENT OF WORK. 2.ALL APPLICABLE BUILDING CODES SHALL BE FOLLOWED FOR PERFORMANCE OF THIS WORK. 3.INSTALLATION OF ALL DUCTWORK SHALL FOLLOW APPLICABLE SMACNA STANDARDS 4.FLEX DUCT LENGTH SHALL NOT EXCEED 6 FT. 5.DUCT DIMENSIONS SHOWN ON THE DRAWINGS INDICATE INSIDE FREE AREA. DUCT LINER SHALL BE ADDED TO OVERALL DIMENSION OF THE DUCT. 6.SPECIAL CONDITIONS APPLY TO ALL DUCTWORK AND PIPING PASSING THROUGH FIRE RATED WALLS. SEE APPLICABLE FIRE CODE FOR FIRE STOPPING REQUIREMENTS. 7.ALL REQUIRED MECHANICAL AND ELECTRICAL EQUIPMENT AND DEVICE ACCESSES SHALL BE MAINTAINED TO THE APPLICABLE CODES FOR ALL MECHANICAL ITEMS SHOWN. 8.REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS AND MOUNTING HEIGHTS OF THERMOSTATS. 9.MECHANICAL OPERATION AND MAINTENANCE MANUALS SHALL BE PROVIDED IN A THREE RING BINDER CONTAINING SUBMITTALS, INSTRUCTIONS, AND WARRANTY (3) REQUIRED. 10.ALL MECHANICAL SYSTEMS SHALL BE TESTED, ADJUSTED, AND BALANCED BY A CERTIFIED PROFESSIONAL TESTING AGENCY (NEBB). 11.VERIFY THAT ALL ROOFTOP EQUIPMENT THAT REQUIRE SERVICING IS NO CLOSER THAN TEN FEET TO ROOF EDGE. A SAFETY RAILING IS REQUIRED FOR ALL EQUIPMENT LESS THAN THIS DISTANCE. SEE INTERNATIONAL MECHANICAL CODE FOR EXACT REQUIREMENTS. PARTIAL HVAC DEMO PLAN SCALE: As Shown ENGINEER: RON RICE DWG. BY: S.R. DATE: 1/24/2023 JOB No.: 2245 M1.0 RE X B U R G , I D A H O RE X B U R G S U R G I C A L C E N T E R Ga t e C i t y E N G I N E E R I N G S E R V I C E S 1 2 2 S O U T H M A I N , P O C A T E L L O , I D 8 3 2 0 4 2 0 8 . 2 2 1 . 9 5 0 6 REVISIONS REV DATE DESCRIPTION Existing Door Not currently drawn - according to Keslin Entrance and Exit for workers Material IN/OUT Dust barriers Dust barriers Dust barriers Dust barriers Wa s t e CBWSJWÑGfFM>VWÑJGWUJÑFXÑÑEWlÑ WHi>GCWEhÑSEVÑViUhÑVWhWUhFfJ•Ñ2BBÑ WBWUhf>USBÑlFf@ÑCiJhÑUFCGBnÑl>hZÑ ½Ž¤ÁÑA64• 1/4"=1'-0" PARTIAL HVAC FLOOR PLAN SCALE: HALL CLEAN UTIL. / STERILE O.R.#1 O.R.#2 BREAK ROOM HALL HALL VEST. VEST. DSSG. T.R. RECOVERY ROOM PREP. SOILED HOLDING RECIEVING STOR. PATIENT EXIT OFFICE CONSULT PREP T.R.REC'P BUSINESS OFFICE WAITING STOR. W.LKR ROOM T.R. FIRE RISER T.R. M.LKR ROOM PREP HALL MECH. CUST. MED GAS ANTH. ROOM SOILED EXISTING RETURN AIR EXISTING RETURN AIR EXISTING RETURN AIR EX I S T I N G R E T U R N A I R EX I S T I N G R E T U R N A I R EX I S T I N G R E T U R N A I R EXISTING SUPPLY AIR EXISTING SUPPLY AIR EXISTING SUPPLY AIR EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EXISTING SUPPLY AIR EXISTING SUPPLY AIR EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EXISTING SUPPLY AIR EXISTING SUPPLY AIR EX I S T I N G R E T U R N A I R 1 RTU 2 RTU 10 RTU 8" Ø 8" Ø 8" Ø 8" Ø EXISTING SUPPLY AIR CONNECT NEW SUPPLY DUCT TO EXISTING SUPPLY DUCT CA P / S E A L EX I S T I N G RG-1 RG-1 CD-1 240 CD-1 240 CD-1 240 CD-1 240 CD-EX 100 CD-EX 250 10 X 10 S.A. 20 X 12 R.A. 12 " Ø 12 X 1 2 S . A . T RTU-10 12 " Ø 14 X 12 S.A. 10 X 1 0 S . A . EX EF EX EF NEW RTU-10 LOCATION TO BE A FIELD VERIFIED AND POSITIONED TO MEET MANUFACTURES REQUIRED CLEARANCES 150 CFM 200 CFM DUCT PENETRATIONS THROUGH SIDE WALL AT EXISTING LOCATIONS IN PARAPET. FIELD VERIFY DIMENSIONS / CONFIGURATION BEFORE ORDERING THYBAR FILTER CURBS. PARTIAL HVAC FLOOR PLAN SCALE: As Shown ENGINEER: RON RICE DWG. BY: S.R. DATE: 1/24/2023 JOB No.: 2245 M2.0 RE X B U R G , I D A H O RE X B U R G S U R G I C A L C E N T E R Ga t e C i t y E N G I N E E R I N G S E R V I C E S 1 2 2 S O U T H M A I N , P O C A T E L L O , I D 8 3 2 0 4 2 0 8 . 2 2 1 . 9 5 0 6 REVISIONS REV DATE DESCRIPTION DUCT CONSTRUCTION & HANGER DETAIL DIMENSION OF LONGEST SIDE, INCHES SHEET METAL GAGE (ALL FOUR SIDES) MINIMUM REINFORCING ANGLE SIZE AND MAX LONGITUDINAL SPACING BETWEEN TRANSVERSE JOINTS AND/OR INTERMEDIATE REINFORCING TRANSVERSE REINFORCING, (I) AT JOINTS UP THRU 12 26 NONE REQ'D 26 26 13 - 18 24 NONE REQ'D 24 24 19 - 30 24 1"x1"x1/8" @ 60"-24 DRIVE SLIP HEMMED S SLIP RECOM- MANDED GAGE RECOM- MANDED GAGE (1) TRANSVERSE REINFORCING SIZE IS DETERMINED BY DIMENSION OF SIDE TO WHICH ANGLE IS APPLIED. METAL FASTENERS - OMARK INSULPING DURO DYNE FASTENERS OR GRIPNAILS. GRIP NAILS SHALL BE INSTALLED BY GRIPNAIL HAMMER GUN OR BY AUTOMATIC FASTENER EQUIPMENT. SELF-TAPPING CADMIUM PLATED HEX HEAD SHEET METAL SCREW HANG DUCTS UP TO 30" WIDTH WITH 1" X 18 GAGE STRAPS @ 10'-0" MAX SPACING STRAPS TO BE TIGHT AGAINST DUCTWORK NO POP RIVETS ALLOWED SHEET METAL DUCT PROVIDE SHEET METAL NOSING OR SLEEVE OVER ANY EXPOSED LINER WHICH FACES THE OPPOSITE DIRECTION AS THE AIRFLOW TOP & BOTTOM SECTION OF LINER SHALL OVERLAP THE SIDES SPACING PER SMACNA (TYP.) DUCT LINER NO MORE THAN 2" FROM EDGE OF LINER ALL ENDS OF LINER TO BE COATED W/ ADHESIVE AND SHALL BE BUTTED FIRMLY TOGETHER NO SCALE VOLUME DAMPER CUT OPENING ACCURATELY FOR SPIN IN (FLARED) FITTING. VOLUME DAMPER. PROVIDE CONCEALED CEILING DAMPER REGULATOR BRANCH DUCT TAKE-OFF DETAIL NO SCALE ALL JOINTS SHALL HAVE A 2" FACING OVERLAYED WITH CIRCUMFERENTIAL JOINTS SEALED WITH 3" WIDE VAPOR BARRIER PRESSURE SENSITIVE FOIL OR VINYL TAPE COMPATIBLE WITH THE FACING. DUCT WRAP 2" THICK, 1.0 lbs. DENSITY DUCT WRAP 2" THICK, 1.0 lbs. DENSITY ROUND DUCT RECTANGULAR DUCT STAPLE LONGITUDINAL JOINTS WITH OUTWARD CLINCHING STAPLES APPROX. 6" ON CENTER AND THEN TAPE THE JOINT WITH 3" WIDE VAPOR BARRIER TAPE. ADHERE INSULATION TO DUCT WITH BONDING ADHESIVE (BENJAMIN FOSTER 85-15 OR I-C-201). FOLDED CORNER DUCT INSULATION DETAIL NO SCALE HANGER STRAPS Ø50" MAX. HANGER STRAP 3 8" BOLT SELF TAPPING CADIUM PLATED HEX HEAD SHEET METAL SCREW. STRAPS TO BE TIGHT AGAINST DUCT ROUND DUCT & STRAP HANGER DETAIL NO SCALE 6" V E R T I C A L GAS LINE CONNECTION DETAIL NO SCALE EQUIPMENT FLEXIBLE GAS CONNECTOR 18" MAX DROP FROM MAIN. SEE PLAN FOR SIZE DRIP LEG SAME AS DROP GROUND JOINT UNION CAPPED PRESSURE TEE GAS PRESSURE REGULATOR 2LB. TO 1/2 OZ. MANUAL SHUT-OFF VALVE SEISMIC PIPING RESTRAINT DETAILS LONGITUDINAL PIPE BRACE TRANSVERSE PIPE BRACING ADD PIPE SLEEVE THAT HAS AN INSIDE DIA. 1/4" LARGER THAN OUTSIDE OF BOLT BOLT TO ANGLE HANGER ROD CLIP OR EQUAL 1 2 MAX DIAGONAL ANGLE PIPE CLAMP HEAVY TYPE OR EQUAL ROD HANGER & VERICAL ANGLE LONGITUDINAL BRACE THREADED BOLT WASHER TO COVER WELD WELDED BEAM ATTACHMENT OR EQUAL PIPE CLAMP HEAVY TYPE OR EQUAL 3/16 TYP. NOTE: SEE STRUCTURAL NOTES FOR DEFERRED SUBMITTAL FOR SEISMIC BRACING. NOTE: CONNECT TO STRUCTURAL SUPPORTING MEMBER TO BE SAME FOR VERTICAL DIAGONAL & LONGITUDINAL ANGLES, NO SCALEROOF TOP UNIT-MOUNTING DETAIL UNIT BASE RAIL 2 X 4 FACTORY WOOD NAILER UNIT HOLD DOWN CLIP (BY MECH, CONTRACTOR) COUNTER FLASHING (BY MECH. CONTRACTOR) CANT STRIP (BY MECH. CONTRACTOR) ROOFING MATERIAL (SEE ARCH DRAWINGS) ROOF INSULATION (VERIFY LOCATION W/ARCH. PLANS) ROOF DECK (SEE ARCH DRAWINGS) RIGID INSULATION (BY MECH. CONTRACTOR) SEE SCHEDULE FOR CONN. TYPE & NO. REQUIRED. ROOF STRUCTURE (SEE STRUCTURAL PLANS ROOF TOP UNIT DUCT FLANGE CONNECTION AT ROOF TOP CURB FLEXIBLE CONN. TO ROOF TOP CURB TRANSITION TO UNIT OPENING FACTORY CURB W/MOUNTING FRAME 1 1/2" RIGID INSULATION FOR SOUND PROOFING (BY MECH. CONTRACTOR) BLOCKING BETWEEN ROOF STRUCTUERE: WOOD - 4X4 BLOCKING W/4X4 HANGER ON EACH END. METAL - 4X4X1/4 ANGLE BLOCKING WELDED TO JOIST TOP CHORDS CONCRETE - NO BLOCKING REQUIRED. SEE DETAIL A DIM. BASED ON ROOFTOP MANUFACTURE FASTEN TO UNIT CURB W/ (2) #12 SCREWS FASTEN TO UNIT BASE RAIL W/ (2) #12 SCREWS UNIT HOLD DOWN CLIP. 14 GAUGE GALV. STEEL ALL DIMENSIONS ARE I.D. (TYP OF 4) NO SCALE & MODEL HVAC ROOFTOP SCHEDULE MANUF. NUMBER NOTESDESCRIPTIONMARKAFUE O.A.TOTAL CFMOUTPUTCOOLING HEATING MOCPVOLTAGEESPHPCFMTONS NOM.SUPPLY FAN MIN. ROOFTOP LENNOX LGT072H4E 6 2400 .8 1.5 30/45 113,000 66,700 240 81%RTU GAS / ELECTRIC INPUT HEATING 150,000 MCA/ FUEL NG ROOFTOPRTU 2 GAS / ELECTRIC 1 CONV. OUTLET, DELTA T-STAT TO MATCH EXISTING ROOFTOP LENNOX LTG036H4E 3 1200 .8 2 19/25 81,000 33,200 200 81%RTU GAS / ELECTRIC 108,000NG10208/3/60 208/3/60 DIFFUSER, GRILLE, & REGISTER SCHEDULE SYMBOL DESCRIPTION NECK NOTESMATERIALPATTERNINSTALLATIONSIZE CD-1 CEILING DIFFUSER STEEL 3 WAY GRILLE SIZE RG-1 STEEL FIXED BLADERETURN GRILLE EER 17 / 12.2 17.8 / 13.3 IEER/ DISCONNECT, HAIL GUARDS, THYBAR FILTER ROOF CURB, DISCONNECT, HAIL GUARDS, THYBAR FILTER ROOF CURB LENNOX LGT072H4E 6 2400 .8 1.5 30/45 113,000 66,700 240 81%150,000NG208/3/60 17 / 12.2 DISCONNECT, HAIL GUARDS, THYBAR FILTER ROOF CURB, CONV. OUTLET, SMOKE DETECTOR CONV. OUTLET, SMOKE DETECTOR STEEL12 X 128" Ø LAY - IN CEILING 14 X 1412" Ø LAY - IN CEILING * FILTRATION BY DYNAMIC AIR QUALITY SOLUTIONS TYPICAL ( DYNAMIC V8 ) * HVAC SCHEDULES AND DETAILS SCALE: As Shown ENGINEER: RON RICE DWG. BY: S.R. DATE: 1/24/2023 JOB No.: 2245 M3.0 RE X B U R G , I D A H O RE X B U R G S U R G I C A L C E N T E R Ga t e C i t y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‹%XLOGLQJ,QIRUPDWLRQ0RGHOLQJ %,0 &OLFNKHUH $XWR&$'‹7HPSODWHV&OLFNKHUH General Notes: Per the HVAC Rooftop Schedule for each of these units, it is required that each unit comes with the following: -Disconnect -Hail Guards - Thybar Filter Roof Curb -Convenience outlet (this will be mounted on each RTU and connected to power by the electrician) -Smoke detector Rooftop Units - Product Data 3URMHFW6XEPLWWDO 3URMHFW1DPH5H[EXUJ0HGLFDO&HQWHU 3DJH 4XRWHRI 7DJ7RQV 0RGHO/*7+(/*7+(<7&21)(  81,729(59,(: 9ROWDJH ,((5 ((5 0&$02&3 DPS *URVV&RROLQJ 7WO6HQV 0%+ 1HW&RROLQJ 7WO6HQV 0%+ 6XSSO\ $LU)ORZ FIP (63763 LQ:& ($7 '%:% ƒ) /$7 '%:% ƒ) 93K +]   &22/,1* &RROLQJ3HUIRUPDQFH 7HPSHUDWXUHV '%:%ƒ) *URVV&RROLQJ 7WO6HQV 0%+$PELHQW  1HW&RROLQJ 7WO6HQV 0%+(QWHULQJ  &RLO0RLVWXUH5HPRYDO OEKU /HDYLQJ² &RLO  6\VWHP0RLVWXUH5HPRYDO OEKU /HDYLQJ² 8QLW  $5,3HUIRUPDQFH &RPSUHVVRUV 5HIULJHUDQW &RQGHQVDWH'UDLQ $5,&RROLQJ 0%+&RROLQJ6WDJHV 7\SH 5$4W\ $5,3RZHU :&RPSUHVVRU4W\&KDUJH /%62=6L]H LQ &RPSUHVVRU5/$DPS 3LSH7KUHDG QSW +($7,1* +HDWLQJ3HUIRUPDQFH 7HPSHUDWXUHV '%:%ƒ) 6SHFLILFDWLRQV 2XWSXW +LJK/RZ ,QSXW +LJK/RZ +HDW5LVH 0%+ 0%+ ƒ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ƒ)WRƒ)ZLWKRXWDQ\DGGLWLRQDOFRQWUROV 3UHFKDUJHG5HIULJHUDWLRQ6\VWHP 7LPHG2II&RQWURO ,QWHUQDO3UHVVXUH5HOLHI9DOYH 7KHUPRVWDW&RQWURO²6WDJHVRI&RROLQJ +HDWLQJ6\VWHP 5HGXQGDQW$XWRPDWLF*DV9DOYHZLWK0DQXDO6KXWRII (OHFWURQLF)ODPH6HQVRU 'LUHFW6SDUN,JQLWLRQ ,QVKRW%XUQHUV $*$&*$&HUWLILHG ,IFRQILJXUHGIRUURRPVHQVRUFRQWURODGGLWLRQDOVWDJLQJPD\EHSRVVLEOH5HIHUWRSHUIRUPDQFHWDEOHVZLWKLQWKH(+% &RQWURO6\VWHP )DQDQG/LPLW&RQWUROV 2YHUORDG3URWHFWLRQ 0LFURSURFHVVRU&RQWUROV²/HQQR[‹&25(&RQWURO6\VWHP $XWRUHVHWKLJK ORZSUHVVXUHVZLWFKZLWKVWULNHORFNRXWIHDWXUHLQ/HQQR[‹&25(&RQWURO6\VWHP %XLOWLQ%$&QHW,3 0673 5HWXUQ$LU6HQVRU)DFWRU\,QVWDOOHG 2XWGRRU$LU6HQVRU)DFWRU\,QVWDOOHG )DFWRU\,QVWDOOHG'LVFKDUJH$LU6HQVRU &RPSOLDQFH &RPSRQHQWVDUH%RQGHGIRU*URXQGLQJ )DFWRU\7HVW2SHUDWHG The drawings do not specify providing new T-stats for the existing units. Engineer/owner to specify if the outlets are to be replaced with these new ones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‹&25(&RQWURO6\VWHPRI\HDUV 3URMHFW6XEPLWWDO 3URMHFW1DPH5H[EXUJ0HGLFDO&HQWHU 3DJH 4XRWHRI &RUQHU:HLJKWV OE &HQWHURI*UDYLW\ LQ $$%%&&''(()) %DVH 0D[%DVH 0D[%DVH 0D[%DVH 0D[%DVH 0D[%DVH 0D[  3URMHFW6XEPLWWDO 3URMHFW1DPH5H[EXUJ0HGLFDO&HQWHU 3DJH 4XRWHRI Due to the existing space on the roof, these clearances may not all be met - especially area C. I've attached snip from the as-built drawings below 3URMHFW6XEPLWWDO 3URMHFW1DPH5H[EXUJ0HGLFDO&HQWHU 3DJH 4XRWHRI 3URMHFW6XEPLWWDO 3URMHFW1DPH5H[EXUJ0HGLFDO&HQWHU 3DJH 4XRWHRI 3URMHFW6XEPLWWDO 3URMHFW1DPH5H[EXUJ0HGLFDO&HQWHU 3DJH 4XRWHRI 3URMHFW6XEPLWWDO 3URMHFW1DPH5H[EXUJ0HGLFDO&HQWHU 3DJH 4XRWHRI 7DJ7RQ 0RGHO/*7+(/*7+(<7&21)6  81,729(59,(: 9ROWDJH 6((5 ((5 0&$02&3 DPS *URVV&RROLQJ 7WO6HQV 0%+ 1HW&RROLQJ 7WO6HQV 0%+ 6XSSO\ $LU)ORZ FIP (63763 LQ:& ($7 '%:% ƒ) /$7 '%:% ƒ) 93K +]   &22/,1* &RROLQJ3HUIRUPDQFH 7HPSHUDWXUHV '%:%ƒ) *URVV&RROLQJ 7WO6HQV 0%+$PELHQW  1HW&RROLQJ 7WO6HQV 0%+(QWHULQJ  &RLO0RLVWXUH5HPRYDO OEKU /HDYLQJ² &RLO  6\VWHP0RLVWXUH5HPRYDO OEKU /HDYLQJ² 8QLW  $5,3HUIRUPDQFH &RPSUHVVRUV 5HIULJHUDQW &RQGHQVDWH'UDLQ $5,&RROLQJ 0%+&RROLQJ6WDJHV 7\SH 5$4W\ $5,3RZHU :&RPSUHVVRU4W\&KDUJH /%62=6L]H LQ &RPSUHVVRU5/$DPS 3LSH7KUHDG QSW +($7,1* +HDWLQJ3HUIRUPDQFH 7HPSHUDWXUHV '%:%ƒ) 6SHFLILFDWLRQV 2XWSXW +LJK/RZ ,QSXW +LJK/RZ +HDW5LVH 0%+ 0%+ ƒ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atural Gas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ƒ)WRƒ)ZLWKRXWDQ\DGGLWLRQDOFRQWUROV 3UHFKDUJHG5HIULJHUDWLRQ6\VWHP 7LPHG2II&RQWURO ,QWHUQDO3UHVVXUH5HOLHI9DOYH 7KHUPRVWDW&RQWURO²6WDJHVRI&RROLQJ +HDWLQJ6\VWHP 5HGXQGDQW$XWRPDWLF*DV9DOYHZLWK0DQXDO6KXWRII (OHFWURQLF)ODPH6HQVRU 'LUHFW6SDUN,JQLWLRQ ,QVKRW%XUQHUV $*$&*$&HUWLILHG ,IFRQILJXUHGIRUURRPVHQVRUFRQWURODGGLWLRQDOVWDJLQJPD\EHSRVVLEOH5HIHUWRSHUIRUPDQFHWDEOHVZLWKLQWKH(+% &RQWURO6\VWHP )DQDQG/LPLW&RQWUROV 2YHUORDG3URWHFWLRQ 0LFURSURFHVVRU&RQWUROV²/HQQR[‹&25(&RQWURO6\VWHP $XWRUHVHWKLJK ORZSUHVVXUHVZLWFKZLWKVWULNHORFNRXWIHDWXUHLQ/HQQR[‹&25(&RQWURO6\VWHP %XLOWLQ%$&QHW,3 0673 5HWXUQ$LU6HQVRU)DFWRU\,QVWDOOHG 2XWGRRU$LU6HQVRU)DFWRU\,QVWDOOHG )DFWRU\,QVWDOOHG'LVFKDUJH$LU6HQVRU &RPSOLDQFH &RPSRQHQWVDUH%RQGHGIRU*URXQGLQJ )DFWRU\7HVW2SHUDWHG $OOPRGHOVDUH$6+5$(HQHUJ\HIILFLHQF\FRPSOLDQWDQGPHHWRUH[FHHGUHTXLUHPHQWVRI6HFWLRQ HVAC Rooftop Schedule calls for this t-stat to be a Delta t-stat to match the existing. Please advise if proposed t-stat is acceptable or if it should be switched to match the existing. Smoke detector required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‹&25(&RQWURO6\VWHPRI\HDUV 3URMHFW6XEPLWWDO 3URMHFW1DPH5H[EXUJ0HGLFDO&HQWHU 3DJH 4XRWHRI &RUQHU:HLJKWV OE &HQWHURI*UDYLW\ LQ $$%%&&''(()) %DVH 0D[%DVH 0D[%DVH 0D[%DVH 0D[%DVH 0D[%DVH 0D[  3URMHFW6XEPLWWDO 3URMHFW1DPH5H[EXUJ0HGLFDO&HQWHU 3DJH 4XRWHRI 3URMHFW6XEPLWWDO 3URMHFW1DPH5H[EXUJ0HGLFDO&HQWHU 3DJH 4XRWHRI Per HVAC Rooftop Schedule - the t-stat for this RTU is to be Delta to match existing. 3URMHFW6XEPLWWDO 3URMHFW1DPH5H[EXUJ0HGLFDO&HQWHU 3DJH 4XRWHRI 3URMHFW6XEPLWWDO 3URMHFW1DPH5H[EXUJ0HGLFDO&HQWHU 3DJH 4XRWHRI Page 1 INSTALLATION INSTRUCTIONS FOR SMOKE DETECTOR KITS USED WITH KC/KG/KH024-090 & LG/LC/LH/LD 036-074 UNITS 506218-02 7/2022 Supersedes 4/2022 2022 D4P120 & D4S SMOKE DETECTOR KITS PACKAGED UNITS KITS AND ACCESSORIES Shipping and Packing List 21Z11; 603408-11 Single-sensor kit contains the following: 1 - Smoke detector sensor 1 - Smoke detector power board 1 - Supply bracket 1 - Supply brace 1 - Return bracket (used on KC, KG & KH units only) 1 - Return brace (used on KC, KG & KH units only) 1 - Power harness 1 - Supply or return air harness 1 - Jumper harness 1 - Metal sampling tube 1 - Plastic exhaust tube 1 - Magnet 1 - Sensor manufacturer's instructions #10 - 16 X 3/4” sheet metal screws #8 - 32 X 1” thread-forming screws 21Z12; 603408-12 Dual-sensor kit contains the following: 2 - Smoke detector sensors 1 - Smoke detector power board 1 - Supply bracket 1 - Supply brace 1 - Return bracket (used on KC, KG & KH units only) 1 - Return brace (used on KC, KG & KH units only) 1 - Power harness 1 - Supply and return air harness 2 - Metal sampling tubes 2 - Plastic exhaust tubes 2 - Magnets 1 - Sensor manufacturer's instructions #10 - 16 X 3/4” sheet metal screws #8 - 32 X 1” thread-forming screws Application LG, LC, LH, and LD Units -- Smoke detector will send a 24Vac signal to the unit controller when smoke is sensed. Unit controller default mode will de-energize unit. KC, KG and KH Units -- Smoke detector will interrupt the 24Vac signal to the unit control circuit when smoke is sensed. Unit will be de-energized. Identify Harnesses Three harnesses are provided in the single sensor kit and two harnesses are provided in the dual sensor kit. Use wire labels, length of harnesses and number and size of connectors to determine appropriate harnesses used in each application. Refer to figure 1 for 53W78 single sensor kits and figure 2 for 54W79 dual sensor kits. Installation Turn the electrical power to unit OFF at disconnect switch. WARNING Improper installation, adjustment, alteration, ser­ vice or maintenance can cause property damage, personal injury or loss of life. Installation and ser­ vice must be performed by a licensed professional installer, service agency or the gas supplier. WARNING To prevent serious injury or death: 1.Lock-out/tag-out before performing maintenance. 2.If system power is required (e.g., smoke detector maintenance), disable power to blower, remove fan belt where applicable, and ensure all controllers and thermostats are set to the “OFF” position before performing maintenance. 3.Always keep hands, hair, clothing, jewelry, tools, etc., away from moving parts. CAUTION As with any mechanical equipment, contact with sharp sheet metal edges can result in personal in­ jury. Take care while handling this equipment and wear gloves and protective clothing. Duct Detectors Page 2 SUPPLY OR RETURN AIR HARNESS - APPROX. 10 FT. IN LENGTH Use this harness in unit return air only AND KG/KC/KH supply air only applications. Discard in LG/LC/LH/LD applications; harness is provided in unit. FIGURE 1 HARNESS IDENTIFICATION (not to scale) 53W78 SINGLE SENSOR KITS (SUPPLY AIR ONLY OR RETURN AIR ONLY APPLICATIONS) POWER HARNESS - 2 FT. IN LENGTH Used in KG/KC/KH applications. Discard in LG/LC/LH/LD applications. JUMPER HARNESS - 4” IN LENGTH Used in LG/LC/LH/LD supply air only applications. Discard harness in other applications. P250-1 P250-2 P250-3 P250-4 P251-1 P251-2 P251-3 P251-4 J261-1 J261-2 J261-3 J261-4 P250-1 P250-2 P250-3 P250-4 J255-1 J255-2 J255-3 J255-4 J255-5 J255-6 95 TB1-C 96 6-PIN 4-PIN 4-PIN 6-PIN 4-PIN J261-5 J261-6 604651 604650 604374 FIGURE 2 POWER HARNESS - 2 FT. IN LENGTH Used in all KG/KC/KH unit applications. Discard in all LG/LC/LH/LD unit applications. P251-1 P251-2 P251-3 P251-4 P250-1 P250-2 P250-3 P250-4 SUPPLY AND RETURN AIR HARNESS - 4 CONNECTORS Used in all dual sensor applications. P252-1 P252-2 P252-3 P252-4 P253-1 P253-2 P253-3 P253-4 BUNDLED TOGETHER J255-1 J255-2 J255-3 J255-4 J255-5 J255-6 95 TB1-C 96 6-PIN 6-PIN4-PIN 4-PIN 4-PIN P252-5 P252-6 HARNESS IDENTIFICATION (not to scale) 53W79 DUAL SENSOR KITS (COMBINATION SUPPLY AIR AND RETURN AIR APPLICATIONS) 604651 603526 Page 3 Installation - continued Smoke detector sensor and power board installation Use manufacturer's instructions provided with smoke detector to install sensor(s) and power board. Refer to figure 3 for location of power board, supply air sensor and return air sensor on units with an economizer. For location of return air sensor on units without an economizer, refer to figure 4 for KC, KG and KH units, and figure 5 for LG, LC, LH, and LD units. Sampling tube installation 1 - Slide metal sampling tube onto the back side of the sensor as shown in figure 6. When sensor is installed in return air applications, slide plastic exhaust tube onto back side of the sensor as shown in figure 6. NOTE - Plastic exhaust tube is NOT used in supply air applications and should be discarded. 2 - Orient sampling tube so that holes point toward the air stream. FIGURE 3 SMOKE DETECTOR COMPONENT LOCATIONS (Units with an Economizer) 0.250 POWER BOARD LOCATION KC, KG and KH Units POWER BOARD LOCATION LG, LC, LH and LD Units RETURN AIR SAMPLING SENSOR (Sampling holes pointing downward) SUPPLY AIR BRACKET SUPPLY AIR BRACE SUPPLY AIR SENSOR (Sampling holes pointing into air stream) SUPPLY AIR SENSOR DETAIL SUPPLY AIR SAMPLING SENSOR (See detail to the right) FIGURE 4 RETURN AIR BRACKET INSTALLATION (KC, KG and KH Units without an Economizer) FRONT OF UNIT BRACKET SIDE MULLION Align 3 holes on bracket with 3 dimples on outside of mullion. BRACKETFRONT MULLION BRACE RETURN AIR FLANGE FRONT MULLION Page 4 FIGURE 5 SMOKE DETECTOR COMPONENT LOCATIONS (LG/LC/LH/LD Units Without an Economizer) RETURN AIR SAMPLING SENSOR (Sampling holes pointing downward) SUPPLY AIR BRACKET SUPPLY AIR BRACE SUPPLY AIR SENSOR (Sampling holes pointed into air stream) FACTORY-INSTALLED RETURN AIR BRACKET SMOKE DETECTOR SENSOR WITH SAMPLING TUBE AND EXHAUST TUBE FIGURE 6 PLASTIC EXHAUST TUBE (Used in return air applications only) SENSOR HEAD MAGNET TEST LOCATION METAL SAMPLING TUBE (Point sampling holes toward air stream) Page 5 FIGURE 7 KC, KG & KH CONTROLS AREA DISCONNECT PINK WIRES LABELED 95 AND 96 Wiring - KG/KC/KH Units 1 - Locate and disconnect pink wires labeled 95 and 96 in the control area above compressor. See figure 7. 2 - Connect wires labeled 95, 96 and TB1-C from the kit harness to wires labeled 95, 96 and TB1-C in unit. 3 - Route harness wires to the top of the unit. Secure to existing bundle of wires and route to control area above compressor. See figure 8. Make sure wires are secured away from other components. 4 - Make jack/plug connections as shown in figure 9 when installing return air smoke detector only, figure 10 when installing supply air smoke detector only, and figure 11 when installing both supply and return air smoke detectors. Refer to respective wiring diagrams in figure 12, 13 and 14. NOTE - In single-sensor applications, the wiring harness is sized for return air applications. There will be excess wiring in supply air applications. Gather excess wire and secure away from other components.FIGURE 8 WIRE ROUTING KG, KC & KH UNITS FILTER ACCESS PANEL ROUTE THROUGH PLASTIC CONDUIT OVER FILTER FRAME ROUTE THROUGH FOAM INSULATION TUBE BE­ TWEEN BLOWER AND COMPRESSOR SECTIONS Connect J255 and P250 harnesses to power board P255 and J250. On dual sensor applications, also connect P252 harness to power board J252. Connect P251 harness to RA sensor J251 OR SA sensor J253. On dual sensor applications, connect RA P251 harness to RA sensor J251 AND P253 harness to J253 SA sensor. Note - Harness routing also applies to LGH/ LCH units in supply air only applications. Refer to “Wiring - LGH/LCH Units” section. Page 6 KC, KG or KH Unit Application with Single Return Air Smoke Detector (Note: Verify that power board DIP switch is set to 1) A171 RETURN AIR SENSOR J251 J255 P255 J250P250 J252 SMOKE DETECTOR POWER BOARD 4 PIN 4 PIN 4 PIN 4 PIN 6 PIN 6 PIN 95 96 TB1-C Power Harness FIGURE 9 6 PIN 1 2 3 4 5 6 1 2 3 4 5 6 P251 Supply or Return Air Harness Kit 53W78 three harnesses provided; discard jumper (shortest) harness. Power Sensor 2 Sensor 1Kit Harnesses KC, KG or KH Unit Application with Single Supply Air Smoke Detector (Note: Verify that power board DIP switch is set to 1) J255 P255 J250 SMOKE DETECTOR POWER BOARD 4 PIN 4 PIN 6 PIN 95 96 TB1-C Power Harness FIGURE 10 6 PIN 1 2 3 4 5 6 1 2 3 4 5 6 Kit 53W78 three harnesses provided; discard jumper harness. A172 SUPPLY AIR SENSOR J253 Power J252 6 PIN Sensor 2 Sensor 1 Kit Harnesses P250 4 PIN 4 PIN P251 Supply or Return Air Harness P252 KC, KG or KH Unit Application with Return Air and Supply Air Smoke Detector (Note: Verify that power board DIP switch is set to 2) J255 P255 SMOKE DETECTOR POWER BOARD 4 PIN 4 PIN 6 PIN 6 PIN 95 96 TB1-C Power Harness FIGURE 11 6 PIN 1 2 3 4 5 6 1 2 3 4 5 6 P253 Kit 53W79 two harnesses provided. A172 SUPPLY AIR SENSOR J253 A171 RETURN AIR SENSOR J251 J250P250 4 PIN 4 PIN 4 PIN 4 PIN P251 Supply and Return Air Harness J252 6 PIN Sensor 2 Sensor 1 Power Kit Harnesses Page 7 FIGURE 12 KG/KC/KH SMOKE DETECTOR WIRING - RETURN AIR ONLY (refer to unit “B” section wiring diagram) POWER HARNESS POWER SENSOR 1 SENSOR 2 SUPPLY OR RETURN AIR ONLY HARNESS KIT HARNESS 96 95 95 96 TB1-C Note - Discard jumper harness. FIGURE 13 KG/KC/KH SMOKE DETECTOR WIRING - SUPPLY AIR ONLY (refer to unit “B” section wiring diagram) POWER HARNESS POWER SENSOR 1 SENSOR 2 SUPPLY OR RETURN AIR ONLY HARNESS KIT HARNESS 96 95 95 96 TB1-C Note - Discard jumper harness. Page 8 FIGURE 14 KG/KC/KH SMOKE DETECTOR WIRING - SUPPLY AND RETURN AIR (refer to unit “B” section wiring diagram) POWER HARNESS POWER SENSOR 1 SENSOR 2 SUPPLY AND RETURN AIR HARNESS (BUNDLED TOGETHER) KIT HARNESS 96 95 95 96 TB1-C Note - Discard jumper harness. Page 9 Wiring - LGH & LCH Units Make jack/plug connections as shown in figure 15 when installing return air smoke detector only, figure 16 when installing supply air smoke detector only and figure 17 when installing both supply and return air smoke detectors. Refer to wiring diagrams in figure 18, 19 and 20. The kit jumper harness is used in single supply air applications only. Route harness as shown in figure 8. Discard harnesses in other applications. P250P251 LCH, or LGH Unit Application with Single Return Air Smoke Detector (Note: Verify that power board DIP switch is set to 1) A171 RETURN AIR SENSOR J251 J255 P255 J250 J252 SMOKE DETECTOR POWER BOARD 4 PIN 4 PIN 4 PIN 4 PIN 6 PIN 6 PIN FIGURE 15 6 PIN Kit 53W78 three harnesses provided; not used in this application.Power Sensor 2 Sensor 1 J255 and P250 provided in control area. P251 provided in return air area. P250 LCH, or LGH Unit Application with Single Supply Air Smoke Detector (Note: Verify that power board DIP switch is set to 1) A172 SUPPLY AIR SENSOR J253 J255 P255 J250 J252 SMOKE DETECTOR POWER BOARD 4 PIN 4 PIN 4 PIN 6 PIN 6 PIN FIGURE 16 6 PIN 4 PIN J261 Kit 53W78 three harnesses provided; use only the jumper harness. Power Sensor 2 Sensor 1 J255 and P252 provided in control area. Jumper Harness P253 4 PIN P252 4 PIN P253 provided in supply air area. P250 P253 LCH or LGH Unit Application with Return Air and Supply Air Smoke Detectors (Note: Change power board DIP switch setting to 2) A171 RETURN AIR SENSOR J251 J255 P255 J250 J252 4 PIN 4 PIN 4 PIN 4 PIN 6 PIN 6 PIN FIGURE 17 6 PIN P251 P252 A172 SUPPLY AIR SENSOR J253 4 PIN 4 PIN 6 PIN SMOKE DETECTOR POWER BOARD Power Sensor 2 Sensor 1 IMPORTANT - Connect 6-pin J255 to connect­ or on harness labeled “power” only; failure to do so could damage smoke detector. Kit 53W78 two harnesses provided; not used in this application. J255, P250 & P252 provided in control area. P251 provided in return air area. P253 provided in supply air area. Page 10 FIGURE 18 LGH/LCH SMOKE DETECTOR WIRING - RETURN AIR ONLY (refer to unit “C” section wiring diagram - rotated 90 degrees) POWER SENSOR 1 SENSOR 2 Note - Discard kit harnesses. UNIT HARNESSES (UNIT HARNESS P252/P253 NOT USED) FIGURE 19 LGH/LCH SMOKE DETECTOR WIRING - SUPPLY AIR ONLY (refer to unit “C” section wiring diagram - rotated 90 degrees) POWER SENSOR 1 SENSOR 2 Note - Discard power and return air harness. UNIT HARNESSES JUMPER HARNESS Page 11 FIGURE 20 LGH/LCH SMOKE DETECTOR WIRING - SUPPLY AND RETURN AIR (refer to unit “C” section wiring diagram - rotated 90 degrees) POWER SENSOR 1 SENSOR 2 Note - Discard kit harnesses. UNIT HARNESSES Page 12 Wiring - LGM, LCM, LGT, LCT, LHT, LDT Make jack/plug connections as shown in figure 21 when installing return air smoke detector only, figure 22 when installing supply air smoke detector only and figure 23 when installing both supply and return air smoke detectors. Refer to wiring diagrams in figure 24. The kit jumper harness is used in single supply air applications only. Route harness as shown in figure 8. Discard harnesses in other applications. P250P251 LGM, LCM, LGT, LCT, LHT, LDT Unit Application with Single Return Air Smoke Detector (Note: Verify that power board DIP switch is set to 1) A171 RETURN AIR SENSOR J251 P255 P255 J250 J252 SMOKE DETECTOR POWER BOARD 4 PIN 4 PIN 4 PIN 4 PIN 6 PIN 6 PIN FIGURE 21 6 PIN Kit 53W78 three harnesses provided; not used in this application.Power Sensor 2 Sensor 1 P255 and P250 provided in control area. P251 provided in return air area. P250 LGM, LCM, LGT, LCT, LHT, LDT Unit Application with Single Supply Air Smoke Detector (Note: Verify that power board DIP switch is set to 1) A172 SUPPLY AIR SENSOR J253 P255 P255 J250 J252 SMOKE DETECTOR POWER BOARD 4 PIN 4 PIN 4 PIN 6 PIN 6 PIN FIGURE 22 6 PIN 4 PIN J261 Kit 53W78 three harnesses provided; use only the jumper harness. Power Sensor 2 Sensor 1 J255 and P252 provided in control area. Jumper Harness P253 4 PIN P252 4 PIN P253 provided in supply air area. P250 P253 LGM, LCM, LGT, LCT, LHT, LDT Unit Application with Return Air and Supply Air Smoke Detectors (Note: Change power board DIP switch setting to 2) A171 RETURN AIR SENSOR J251 P255 P255 J250 J252 4 PIN 4 PIN 4 PIN 4 PIN 6 PIN 6 PIN FIGURE 23 6 PIN P251 P252 A172 SUPPLY AIR SENSOR J253 4 PIN 4 PIN 6 PIN SMOKE DETECTOR POWER BOARD Power Sensor 2 Sensor 1 IMPORTANT - Connect 6-pin J255 to connect­ or on harness labeled “power” only; failure to do so could damage smoke detector. Kit 53W78 two harnesses provided; not used in this application. P255, P250 & P252 provided in control area. P251 provided in return air area. P253 provided in supply air area. Page 13 WH T BL U WH T PN K GR Y Y R R B Y Y 15 Y B 16 17 1 2 1 2 1 1 9102456378 1023 981 456 7 02 03 04 05 06 07 08 09 10 01 AA BB CC EEDD FF Voltage: All Voltages Model: LC, LG, LH, LD Series RTU Supersedes:N/A Form No: Thermostat Rev:0 4 P2 5 5 P 2 5 5 361 2 1 P251 J251 1 J250 P250 2 3 4 2 3 4 1 P253 J253 2 3 4 1 J252 P252 2 3 4 3 1 8 7 2 1234 231231 B A 13 A5 5 . J 2 9 7 62 2 A5 5 . J 2 9 7 67 23 9876 RE D RE D 1 RE D RE D 234 5 678910 YE L YEL YEL YEL YEL RED RED BLK BLK 10 GR Y RE D RE D 12 J2 6 1 YEL YEL YEL YEL RED RED BLK BLK RE D −BL K GR Y RE D −BL K GR Y YEL YEL YEL YEL PNK PNK GRY GRY 4 YE L YE L PN K GR Y 12 RED A55 MAIN CTRL GN D CTRL SMOKE DETECT A173 SE N S O R 1 SE N S O R 2 FIRE ALARM CONTACT SUPPLIED BY OTHERS A5 5 . J 2 9 9 DI−1R 538078− 01 Re v 0 538078−01 HEATI NG SECTI ONA COOLI NG SECTI ONB WI RI NG DI AGRAM FLOW SECTI ONB3 COOLI NG SECTI ONC ACCS SECTI OND ACCS GN D P299 J299 P387 J387 FR E E TO M 4 T H E R M O S T A T I N P U T ALL OTHER THERMOSTAT SIGNALS REMAIN CONNECTED AS SHOWN ON THE TOP TO PROVIDE THREE COMPRESSOR STAGES. REQUIRES 3 HEAT, 3 COOL THERMOSTAT AND K27 RELAY GN D W1 Y1 OC P GL O DO −1 Y2R TE M P FR E E AI −2 C RGN D S2 7 GN D 24 V A C S1 4 9 R C AI −1 GN D HU M G DI −1 RR DI −4 C FR E E C DI −2 R DI −3 TO PROVIDE SUPERMARKET REHEAT SCHEME USE S86 DEHUMIDISTAT AND K55 C 54 J297 P297 J298 P298 A5 5 . J 2 9 8 A5 5 . J 2 9 8 A5 5 . J 2 9 8 S5 2 W2 1,5 2 3 4 5 6 77 7 RCG Y1 CY1 Y2 R C IAQ+ IAQ+CR RIAQ+IAQ−C SUPERMARKET REHEAT 3 STAGE COOLING/ 3 STAGE HEATING DENOTES OPTIONAL COMPONENTS AND WIRING CLASS II FIELD WIRING 5 8 9 FIGURE 24 LGM, LCM, LGT, LCT, LHT, LDT SMOKE DETECTOR WIRING - SUPPLY AND RETURN AIR (refer to unit “C” section wiring diagram - rotated 90 degrees) Page 14 Test Magnet(s) A test magnet is provided in a bag assembly with each sensor. Remove the magnet from the bag assembly and place it on a metal surface near the sensor. The magnet is used during test procedures. Maintenance and Test Procedure Instructions The sensor manufacturer's instructions, which are provided with each sensor, outline information on maintenance and test procedures. Place these instructions in the literature pouch for future reference. P250 LG/LC/LH/LD Unit Application with Single Supply Air Smoke Detector (Note: Verify that power board DIP switch is set to 1) A172 SUPPLY AIR SENSOR J253 J255 P255 J250 J252 SMOKE DETECTOR POWER BOARD 4 PIN 4 PIN4 PIN 6 PIN 6 PIN FIGURE 25 6 PIN 4 PIN J261 Kit 53W78 three harnesses provided; use only the jumper harness. Power Sensor 2 Sensor 1 J255 and P252 provided in control area. Jumper Harness P253 4 PIN P252 4 PIN P253 provided in supply air area. J253 4 PIN P253 4 PIN J253 4 PIN4 PIN J261 P253 4 PIN P252 4 PIN P253 provided in supply air area. J253 4 PIN P253 4 PIN A172 SUPPLY AIR SENSOR SMOKE DETECTOR POWER BOARD