HomeMy WebLinkAboutREDLINED PLANS - 23-00884 - 65 Aries St - Duplex ConversionAuthor Name Author Email Author Phone No.:
Larry Beesley Larry.Beesley@rexburg.org 208-372-2176
Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164
Description : 65 Aries St - Duplex Conversion
Address : 65 Aries St Units 1 & 2
Application Type :
Document Filename : 20231127_101841.jpg Array
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report
Revisions Required
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
Pg 1 Free Text Larry Beesley : Building Open 1 All ceilings must have a 2 hour fire separation, add another
layer of 5/8" type x drywall
Pg 1 Free Text Larry Beesley : Building Open 1 All separation walls must have 5/8" type X drywall on both
sides for a 1hour rating on each side.
Pg 1 Free Text Larry Beesley : Building Open 1 2A10BC fire extinguisher
Pg 1 Free Text Larry Beesley : Building Open 1 SMOKE DETECTOR REQUIRED
Pg 1 Free Text Larry Beesley : Building Open 1 SD
Pg 1 Free Text Larry Beesley : Building Open 1 SD
Pg 1 Free Text Larry Beesley : Building Open 1 SD CM
Pg 1 Free Text Larry Beesley : Building Open 1 All of your recessed lights will have to be changed to Fire rated
canned lights or regular ceiling lights with fire rated boxes.
Pg 1 Free Text Larry Beesley : Building Open 1 Footing and foundation will both need inspections for the
rebar and size.
Pg 1 Free Text Kyle Baldwin : P&Z Open 1 Please submit Site plan for parking requirement verification
Is this a basement conversion? garage conversion?
# 23-00884
Duplex Conversion
Please digitally re-submit all pages of the plan set in response to requested revisions
for our next review cycle, with noted items resolved.
I entered some redlines and notes of things that will need to be done. Electrical and plumbing also have requirements on this conversion. They went over most of the items
when we did the walk through with you this past summer. If you have any questions you can call any of us. The building part is good to go, Planning and Zoning just has to
approve your parking.
Report Date: 11.29.2023
Approval of plans does not constitute approval of variance from code
Page 1 of 1
Powered by TCPDF (www.tcpdf.org)
2A10BC fire
extinguisher
All o f y o ur rec essed lights w ill ha v e to b e
c ha nged to F ire ra ted c a nned lights o r
regula r c eiling lights w ith fire ra ted b o xes.
All c eilings m ust ha v e a 2 ho ur
fire sep a ra tio n, a d d a no ther la y er
o f 5 /8 " ty p e x d ry w a ll
S D
S D
F o o ting a nd fo und a tio n w ill
b o th need insp ec tio ns fo r
the reb a r a nd siz e.
S D CM
P lea se sub m it S ite p la n fo r
p a rk ing req uirem ent v erific a tio n
Is this a b a sem ent c o nv ersio n?
ga ra ge c o nv ersio n?
S M O K E D E T E CT O R R E Q U IR E D
All sep a ra tio n w a lls m ust ha v e
5 /8 " ty p e X d ry w a ll o n b o th sid es
fo r a 1ho ur ra ting o n ea c h sid e.