HomeMy WebLinkAboutLOAD SHORT FORM - 22-00647 - 736 Hillside Drive - New SFRCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Mar-20 14:30:27 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 1 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Load Short Form 02/23/2023Date:Entire House Brian J BennettBy: The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net Project Information Tallman ConstructionFor: Ammon, Id 83406 Phone: 208-403-5858 Email: Scott@tallmanconstruction.com Design Information InfiltrationClgHtg SimplifiedMethod89-2Outside db (°F) TightConstruction quality7570Inside db (°F) 0Fireplaces1472Design TD (°F) H-Daily range 5030Inside humidity (%) -2834Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Coleman, Unitary Products Group Make Coleman, Unitary Products Group Trade COLEMAN BY JOHNSON CONTROLS Trade COLEMAN Model CP9C060B12MP13 Cond TF4B2421 AHRI ref 204829753 Coil C(A,C,D,E)30D44+CP9C080B12MP12+TDR AHRI ref 8713065 Efficiency 97.5 AFUE Efficiency 13.2 EER, 17 SEER Heating input Btuh60000 Sensible cooling Btuh21600 Heating output Btuh58000 Latent cooling Btuh2400 Temperature rise °F50 Total cooling Btuh24000 Actual air flow cfm1255 Actual air flow cfm1255 Air flow factor cfm/Btuh0.032 Air flow factor cfm/Btuh0.069 Static pressure in H2O0.65 Static pressure in H2O0.65 Space thermostat Load sensible heat ratio 0.95 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Bed 4 240 2054 829 66 57 Bath 3 T 56 1148 331 37 23 cls 4 19 0 0 0 0 Bath 3 42 0 0 0 0 Bed 6 237 1516 1364 49 94 Linen 6 0 0 0 0 Family Room 1031 7215 3419 234 237 Bed 5 262 1211 1138 39 79 Mechanical/ST 452 2954 380 96 26 Master T 30 901 232 29 16 Master Bath 136 1205 725 39 50 Master Cls 89 1125 346 36 24 Laundry 108 483 514 16 36 Master Bed 252 2470 1079 80 75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Mar-20 14:30:27 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 2 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S Mud 104 1907 577 62 40 Office 75 120 0 4 0 Kit/Live/Dine 1028 9035 4190 292 290 Pantry 84 0 0 0 0 Bath 2 84 917 512 30 35 Bed 2 203 2789 1512 90 105 Bed 3 155 1723 983 56 68 Entire House 4691 38773 18131 1255 1255 Other equip loads 0 0 Equip. @ 0.94 RSM 17116 Latent cooling 1003 TOTALS 4691 38773 18119 1255 1255 2023-Mar-20 14:30:27 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 1 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Building Analysis 02/23/2023Date:Entire House Brian J BennettBy: The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net Project Information Tallman ConstructionFor: Ammon, Id 83406 Phone: 208-403-5858 Email: Scott@tallmanconstruction.com Design Conditions Location:CoolingHeatingIndoor:7570Indoor temperature (°F)Idaho Falls Fanning Field, ID, US 1472Design TD (°F)ft4744Elevation: 5030Relative humidity (%)°N44Latitude: Outdoor:-28.034.3Moisture difference (gr/lb)CoolingHeating Infiltration:89-2Dry bulb (°F) SimplifiedMethod)H(34-Daily range (°F) TightConstruction quality61-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Doors Ceilings Floors Infiltration % of loadBtuhBtuh/ft²Component 35.6138003.7Walls 32.61265021.8Glazing 4.8186428.2Doors 8.834001.4Ceilings 9.637391.61.6Floors 8.633211.1Infiltration 00Ducts 00Piping 00Humidification 00Ventilation0Adjustments 100.038773Total Cooling Walls Glazing Doors Ceilings Other Internal Gains % of loadBtuhBtuh/ft²Component 10.919760.5Walls 55.41004117.3Glazing 2.74857.4Doors 11.019890.8Ceilings 000Floors 1.83300.1Infiltration 00Ducts 00Ventilation 18.33310Internal gains 00Blower 0Adjustments 100.018131Total Latent Cooling Load = 1003 Btuh Overall U-value = 0.054 Btuh/ft²-°F ERROR: negative wall area in Bed 4 - check windows. 2023-Mar-20 14:30:27 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 1 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Component Constructions 02/23/2023Date:Entire House Brian J BennettBy: The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net Project Information Tallman ConstructionFor: Ammon, Id 83406 Phone: 208-403-5858 Email: Scott@tallmanconstruction.com Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temperature (°F)Idaho Falls Fanning Field, ID, US 1472Design TD (°F)ft4744Elevation: 5030Relative humidity (%)°N44Latitude: Outdoor:-28.034.3Moisture difference (gr/lb)CoolingHeating Infiltration:89-2Dry bulb (°F) SimplifiedMethod)H(34-Daily range (°F) TightConstruction quality61-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 15B19-0wc-8: Bg wall, heavy dry or light damp soil, 2"x4" wood int frm, concrete wall, r-19 cav ins, 8" thk 50.0115103.0019.00.040504e 110.0215633.1319.00.040500s 90.0214402.9919.00.040482w 260.0236032.7719.00.0401303all R-22 Frame Wall: Frm wall, brk 4" ext, 1/2" wood shth, r-22 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 6650.8034774.2022.00.058828n 5030.8026294.2022.00.058626e 2930.8015314.2022.00.058365s 4810.8025134.2022.00.058598w 90.80474.2022.00.05811nw 19510.80101964.2022.00.0582428all Partitions (none) Windows 4A5-2ov: 2 glazing, clr low-e outr, argon gas, insulated vinyl frm mat, clr innr, 1/2" gap, 1/4" thk; NFRC rated (SHGC=0.31); 6.67 ft head ht 104110.2221521.700.300102n 81610.2173821.700.30080n 147010.2312821.700.300144n 120033.378221.700.30036e 103133.367221.700.30031e 202818.3241121.700.300111s 120033.378221.700.30036w 110233.371821.700.30033w 988717.31244621.700.300573all 4A5-2ov: 2 glazing, clr low-e outr, argon gas, insulated vinyl frm mat, clr innr, 1/2" gap, 1/4" thk; 6.67 ft head ht 15425.620434.000.4706nw Doors 11D0: Door, wd sc type 1767.3567828.200.39024s 1547.3559328.200.39021w 1547.3559328.200.39021nw 4857.35186428.200.39066all Ceilings 2023-Mar-20 14:30:27 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 2 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 19890.8534001.4550.00.0202348 Floors 21A-28t: Bg floor, heavy dry or light damp soil, 6.5' depth 00.0222348 0037391.59 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Mar-20 14:30:27 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 1 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Project Summary 02/23/2023Date:Entire House Brian J BennettBy: The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net Project Information Tallman ConstructionFor:Ammon, Id 83406 Phone: 208-403-5858Email: Scott@tallmanconstruction.com ResCheck OnlyNotes: Design Information Idaho Falls Fanning Field, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-2 Outside db °F89Inside db °F70 Inside db °F75 Design TD °F72 Design TD °F14Daily range H Relative humidity %50Moisture difference gr/lb-28 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh38773 Structure Btuh18131 Ducts Btuh0 Ducts Btuh0Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none) (none)Humidification Btuh0Blower Btuh0 Piping Btuh0Equipment load Btuh38773 Use manufacturer's data n Rate/swing multiplier 0.94InfiltrationEquipment sensible load Btuh17116 Method Latent Cooling Equipment Load SizingSimplified Construction quality Tight0Fireplaces Structure Btuh1003 Ducts Btuh0Central vent (0 cfm) Btuh0 CoolingHeating (none)46914691Area (ft²) Equipment latent load Btuh1003 2978429784Volume (ft³)Air changes/hour 0.050.10 Equipment Total Load (Sen+Lat)Btuh18119 Equiv. AVF (cfm) 2550 Req. total capacity at 0.90 SHR ton1.6 Heating Equipment Summary Cooling Equipment Summary Make Coleman, Unitary Products Group Make Coleman, Unitary Products GroupTrade COLEMAN BY JOHNSON CONTROLS Trade COLEMAN Model CP9C060B12MP13 Cond TF4B2421AHRI ref 204829753 Coil C(A,C,D,E)30D44+CP9C080B12MP12+TDR AHRI ref 8713065Efficiency 97.5 AFUE Efficiency 13.2 EER, 17 SEER Heating input Btuh60000 Sensible cooling Btuh21600Heating output Btuh58000 Latent cooling Btuh2400 Temperature rise °F50 Total cooling Btuh24000Actual air flow cfm1255 Actual air flow cfm1255 Air flow factor cfm/Btuh0.032 Air flow factor cfm/Btuh0.069Static pressure in H2O0.65 Static pressure in H2O0.65 Space thermostat Load sensible heat ratio 0.95 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Mar-20 14:30:27Right-Suite® Universal 2022 22.0.04 RSU01476 Page 1...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Right-J® Worksheet 02/23/2023Date:Entire House Brian J BennettBy:The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net 1 Room name Entire House Bed 4 2 Exposed wall 486.2 ft 30.5 ft 3 Room height 9.0 ft 9.0 heat/coolft 4 Room dimensions ft239.8x1.0 5 Room area 4691.0 ft²239.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nn 5.005.00 0.000.00 0 -182 -909 0 0 -32 -160 0 .GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 102 0 2215 1041 32 0 695 327 .GG 4A5-2ovd4A5-2ovd 0.3000.300 nn 21.7221.72 10.2110.21 80 0 1738 816 0 0 0 0 .WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nn 4.204.20 0.800.80 972 828 3477 665 126 126 529 101 11 GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 144 0 3128 1470 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ee 3.003.00 0.010.01 540 504 1510 5 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 36 0 782 1200 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ee 4.204.20 0.800.80 657 626 2629 503 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 31 0 672 1031 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ss 3.133.13 0.020.02 500 500 1563 11 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ss 4.204.20 0.800.80 500 365 1531 293 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ss 21.7221.72 18.2718.27 111 0 2411 2028 0 0 0 0 DD 11D011D0 0.3900.390 ss 28.2428.24 7.357.35 24 24 678 176 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ww 2.992.99 0.020.02 518 482 1440 9 149 149 465 3 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 36 0 782 1200 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ww 4.204.20 0.800.80 653 598 2513 481 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 33 0 718 1102 0 0 0 0 DD 11D011D0 0.3900.390 ww 28.2428.24 7.357.35 21 21 593 154 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nwnw 4.204.20 0.800.80 38 11 47 9 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 nwnw 34.0334.03 25.5925.59 6 0 204 154 0 0 0 0 DD 11D011D0 0.3900.390 nwnw 28.2428.24 7.357.35 21 21 593 154 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.451.45 0.850.85 2348 2348 3400 1989 240 240 347 203 FF 21A-28t21A-28t 0.0220.022 --1.591.59 0.000.00 2348 2348 3739 0 0 0 0 0 6 c) AED excursion 0 -62 Envelope loss/gain 35452 14491 1876 572 12 a) Infiltration 3321 330 158 16 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 7 1610 1 230 Appliances/other 1700 0 Subtotal (lines 6 to 13)38773 18131 2034 818 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 20 11 14 Subtotal 38773 18131 2054 829 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 38773 18131 2054 829 Air required (cfm)Air required (cfm)1255 1255 66 57 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Mar-20 14:30:27Right-Suite® Universal 2022 22.0.04 RSU01476 Page 2...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Right-J® Worksheet 02/23/2023Date:Entire House Brian J BennettBy:The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net 1 Room name Bath 3 T cls 4 2 Exposed wall 15.5 ft 0ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft56.0x1.0 ft7.5x2.5 5 Room area 56.0 ft²18.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nn 5.005.00 0.000.00 0 -16 -80 0 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 16 0 348 163 0 0 0 0 .GG 4A5-2ovd4A5-2ovd 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 .WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nn 4.204.20 0.800.80 81 81 340 65 0 0 0 0 11 GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ee 3.003.00 0.010.01 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ee 4.204.20 0.800.80 59 59 246 47 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ss 3.133.13 0.020.02 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ss 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ss 21.7221.72 18.2718.27 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ww 2.992.99 0.020.02 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ww 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nwnw 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 nwnw 34.0334.03 25.5925.59 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nwnw 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.451.45 0.850.85 56 56 81 47 19 19 27 16 FF 21A-28t21A-28t 0.0220.022 --1.591.59 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -24 -1 Envelope loss/gain 934 299 27 15 12 a) Infiltration 155 15 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1089 314 27 15 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 58 17 -27 -15 14 Subtotal 1148 331 0 0 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1148 331 0 0 Air required (cfm)Air required (cfm)37 23 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Mar-20 14:30:27Right-Suite® Universal 2022 22.0.04 RSU01476 Page 3...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Right-J® Worksheet 02/23/2023Date:Entire House Brian J BennettBy:The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net 1 Room name Bath 3 Bed 6 2 Exposed wall 2.5 ft 28.5 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft6.5x6.5 ft236.8x1.0 5 Room area 42.3 ft²236.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nn 5.005.00 0.000.00 0 0 0 0 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 .GG 4A5-2ovd4A5-2ovd 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 .WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nn 4.204.20 0.800.80 0 0 0 0 0 0 0 0 11 GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ee 3.003.00 0.010.01 23 23 70 1 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ee 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ss 3.133.13 0.020.02 0 0 0 0 135 135 422 3 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ss 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ss 21.7221.72 18.2718.27 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ww 2.992.99 0.020.02 0 0 0 0 122 102 280 0 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 20 0 434 667 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ww 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nwnw 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 nwnw 34.0334.03 25.5925.59 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nwnw 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.451.45 0.850.85 42 42 61 36 237 237 343 201 FF 21A-28t21A-28t 0.0220.022 --1.591.59 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -3 259 Envelope loss/gain 132 34 1480 1129 12 a) Infiltration 3 0 32 3 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13)134 34 1512 1362 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -134 -34 4 2 14 Subtotal 0 0 1516 1364 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 1516 1364 Air required (cfm)Air required (cfm)0 0 49 94 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Mar-20 14:30:27Right-Suite® Universal 2022 22.0.04 RSU01476 Page 4...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Right-J® Worksheet 02/23/2023Date:Entire House Brian J BennettBy:The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net 1 Room name Linen Family Room 2 Exposed wall 0ft 71.5 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft3.0x2.0 ft1030.5x1.0 5 Room area 6.0 ft²1030.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nn 5.005.00 0.000.00 0 0 0 0 0 -134 -669 0 .GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 54 0 1173 551 .GG 4A5-2ovd4A5-2ovd 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 80 0 1738 816 .WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nn 4.204.20 0.800.80 0 0 0 0 293 293 1228 235 11 GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ee 3.003.00 0.010.01 0 0 0 0 270 254 765 3 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 16 0 348 533 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ee 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ss 3.133.13 0.020.02 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ss 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ss 21.7221.72 18.2718.27 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ww 2.992.99 0.020.02 0 0 0 0 0 -16 -80 0 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 16 0 348 533 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ww 4.204.20 0.800.80 0 0 0 0 81 81 340 65 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nwnw 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 nwnw 34.0334.03 25.5925.59 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nwnw 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.451.45 0.850.85 6 6 9 5 1031 1031 1492 873 FF 21A-28t21A-28t 0.0220.022 --1.591.59 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 0 -257 Envelope loss/gain 9 5 6682 3352 12 a) Infiltration 0 0 448 45 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)9 5 7130 3397 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -9 -5 86 22 14 Subtotal 0 0 7215 3419 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 7215 3419 Air required (cfm)Air required (cfm)0 0 234 237 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Mar-20 14:30:27Right-Suite® Universal 2022 22.0.04 RSU01476 Page 5...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Right-J® Worksheet 02/23/2023Date:Entire House Brian J BennettBy:The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net 1 Room name Bed 5 Mechanical/ST 2 Exposed wall 17.0 ft 78.5 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft261.5x1.0 ft451.8x1.0 5 Room area 261.5 ft²451.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nn 5.005.00 0.000.00 0 0 0 0 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 .GG 4A5-2ovd4A5-2ovd 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 .WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nn 4.204.20 0.800.80 0 0 0 0 0 0 0 0 11 GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ee 3.003.00 0.010.01 153 133 379 0 95 95 296 2 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 20 0 434 667 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ee 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ss 3.133.13 0.020.02 0 0 0 0 365 365 1141 8 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ss 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ss 21.7221.72 18.2718.27 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ww 2.992.99 0.020.02 0 0 0 0 248 248 774 6 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ww 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nwnw 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 nwnw 34.0334.03 25.5925.59 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nwnw 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.451.45 0.850.85 262 262 379 221 452 452 654 383 FF 21A-28t21A-28t 0.0220.022 --1.591.59 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 18 -29 Envelope loss/gain 1192 906 2865 370 12 a) Infiltration 19 2 87 9 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1211 1138 2952 379 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 2 1 14 Subtotal 1211 1138 2954 380 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1211 1138 2954 380 Air required (cfm)Air required (cfm)39 79 96 26 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Mar-20 14:30:27Right-Suite® Universal 2022 22.0.04 RSU01476 Page 6...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Right-J® Worksheet 02/23/2023Date:Entire House Brian J BennettBy:The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net 1 Room name Master T Master Bath 2 Exposed wall 12.0 ft 16.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft3.5x8.5 ft16.0x8.5 5 Room area 29.8 ft²136.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nn 5.005.00 0.000.00 0 0 0 0 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 .GG 4A5-2ovd4A5-2ovd 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 .WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nn 4.204.20 0.800.80 77 61 254 49 0 0 0 0 11 GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 16 0 348 163 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ee 3.003.00 0.010.01 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ee 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ss 3.133.13 0.020.02 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ss 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ss 21.7221.72 18.2718.27 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ww 2.992.99 0.020.02 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ww 4.204.20 0.800.80 32 32 132 25 144 131 551 105 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 13 0 278 427 DD 11D011D0 0.3900.390 ww 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nwnw 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 nwnw 34.0334.03 25.5925.59 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nwnw 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.451.45 0.850.85 0 0 0 0 0 0 0 0 FF 21A-28t21A-28t 0.0220.022 --1.591.59 0.000.00 30 30 47 0 136 136 217 0 6 c) AED excursion -18 177 Envelope loss/gain 781 220 1046 709 12 a) Infiltration 120 12 160 16 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)901 232 1205 725 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 901 232 1205 725 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 901 232 1205 725 Air required (cfm)Air required (cfm)29 16 39 50 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Mar-20 14:30:27Right-Suite® Universal 2022 22.0.04 RSU01476 Page 7...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Right-J® Worksheet 02/23/2023Date:Entire House Brian J BennettBy:The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net 1 Room name Master Cls Laundry 2 Exposed wall 19.0 ft 6.5 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft10.5x8.5 ft13.5x8.0 5 Room area 89.3 ft²108.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nn 5.005.00 0.000.00 0 0 0 0 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 .GG 4A5-2ovd4A5-2ovd 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 .WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nn 4.204.20 0.800.80 0 0 0 0 0 0 0 0 11 GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ee 3.003.00 0.010.01 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ee 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ss 3.133.13 0.020.02 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ss 4.204.20 0.800.80 77 77 321 61 59 59 246 47 GG 4A5-2ov4A5-2ov 0.3000.300 ss 21.7221.72 18.2718.27 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ww 2.992.99 0.020.02 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ww 4.204.20 0.800.80 95 90 379 72 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 4 0 93 142 0 0 0 0 DD 11D011D0 0.3900.390 ww 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nwnw 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 nwnw 34.0334.03 25.5925.59 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nwnw 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.451.45 0.850.85 0 0 0 0 0 0 0 0 FF 21A-28t21A-28t 0.0220.022 --1.591.59 0.000.00 89 89 142 0 108 108 172 0 6 c) AED excursion 51 -39 Envelope loss/gain 935 327 418 8 12 a) Infiltration 190 19 65 6 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13)1125 346 483 514 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1125 346 483 514 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1125 346 483 514 Air required (cfm)Air required (cfm)36 24 16 36 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Mar-20 14:30:27Right-Suite® Universal 2022 22.0.04 RSU01476 Page 8...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Right-J® Worksheet 02/23/2023Date:Entire House Brian J BennettBy:The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net 1 Room name Master Bed Mud 2 Exposed wall 23.5 ft 21.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft251.8x1.0 ft13.0x8.0 5 Room area 251.8 ft²104.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nn 5.005.00 0.000.00 0 0 0 0 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 .GG 4A5-2ovd4A5-2ovd 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 .WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nn 4.204.20 0.800.80 131 77 321 61 0 0 0 0 11 GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 54 0 1173 551 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ee 3.003.00 0.010.01 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ee 4.204.20 0.800.80 81 81 340 65 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ss 3.133.13 0.020.02 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ss 4.204.20 0.800.80 0 0 0 0 72 59 246 47 GG 4A5-2ov4A5-2ov 0.3000.300 ss 21.7221.72 18.2718.27 0 0 0 0 13 0 290 244 DD 11D011D0 0.3900.390 ss 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ww 2.992.99 0.020.02 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ww 4.204.20 0.800.80 0 0 0 0 117 96 403 77 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 28.2428.24 7.357.35 0 0 0 0 21 21 593 154 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nwnw 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 nwnw 34.0334.03 25.5925.59 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nwnw 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.451.45 0.850.85 0 0 0 0 0 0 0 0 FF 21A-28t21A-28t 0.0220.022 --1.591.59 0.000.00 252 252 401 0 104 104 166 0 6 c) AED excursion -82 34 Envelope loss/gain 2235 596 1698 556 12 a) Infiltration 235 23 210 21 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2470 1079 1907 577 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 2470 1079 1907 577 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2470 1079 1907 577 Air required (cfm)Air required (cfm)80 75 62 40 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Mar-20 14:30:27Right-Suite® Universal 2022 22.0.04 RSU01476 Page 9...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Right-J® Worksheet 02/23/2023Date:Entire House Brian J BennettBy:The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net 1 Room name Office Kit/Live/Dine 2 Exposed wall 0ft 73.7 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft75.3x1.0 ft1027.5x1.0 5 Room area 75.3 ft²1027.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nn 5.005.00 0.000.00 0 0 0 0 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 .GG 4A5-2ovd4A5-2ovd 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 .WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nn 4.204.20 0.800.80 0 0 0 0 266 192 804 154 11 GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 74 0 1607 755 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ee 3.003.00 0.010.01 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ee 4.204.20 0.800.80 0 0 0 0 248 232 972 186 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 16 0 348 533 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ss 3.133.13 0.020.02 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ss 4.204.20 0.800.80 0 0 0 0 59 13 55 11 GG 4A5-2ov4A5-2ov 0.3000.300 ss 21.7221.72 18.2718.27 0 0 0 0 21 0 463 390 DD 11D011D0 0.3900.390 ss 28.2428.24 7.357.35 0 0 0 0 24 24 678 176 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ww 2.992.99 0.020.02 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ww 4.204.20 0.800.80 0 0 0 0 54 38 160 31 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 16 0 348 533 DD 11D011D0 0.3900.390 ww 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nwnw 4.204.20 0.800.80 0 0 0 0 38 11 47 9 GG 4A5-2ov4A5-2ov 0.4700.470 nwnw 34.0334.03 25.5925.59 0 0 0 0 6 0 204 154 DD 11D011D0 0.3900.390 nwnw 28.2428.24 7.357.35 0 0 0 0 21 21 593 154 CC 16B-50ad16B-50ad 0.0200.020 --1.451.45 0.850.85 0 0 0 0 5 5 7 4 FF 21A-28t21A-28t 0.0220.022 --1.591.59 0.000.00 75 75 120 0 1028 1028 1637 0 6 c) AED excursion 0 -307 Envelope loss/gain 120 0 7922 2782 12 a) Infiltration 0 0 737 73 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 1200 Subtotal (lines 6 to 13)120 0 8658 4056 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 377 135 14 Subtotal 120 0 9035 4190 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 120 0 9035 4190 Air required (cfm)Air required (cfm)4 0 292 290 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Mar-20 14:30:27Right-Suite® Universal 2022 22.0.04 RSU01476 Page 10...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Right-J® Worksheet 02/23/2023Date:Entire House Brian J BennettBy:The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net 1 Room name Pantry Bath 2 2 Exposed wall 8.0 ft 8.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft8.0x10.5 ft8.0x10.5 5 Room area 84.0 ft²84.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nn 5.005.00 0.000.00 0 0 0 0 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 .GG 4A5-2ovd4A5-2ovd 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 .WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nn 4.204.20 0.800.80 0 0 0 0 0 0 0 0 11 GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ee 3.003.00 0.010.01 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ee 4.204.20 0.800.80 72 68 284 54 72 61 258 49 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 4 0 93 142 11 0 232 356 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ss 3.133.13 0.020.02 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ss 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ss 21.7221.72 18.2718.27 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ww 2.992.99 0.020.02 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ww 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nwnw 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 nwnw 34.0334.03 25.5925.59 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nwnw 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.451.45 0.850.85 0 0 0 0 0 0 0 0 FF 21A-28t21A-28t 0.0220.022 --1.591.59 0.000.00 84 84 134 0 84 84 134 0 6 c) AED excursion 6 23 Envelope loss/gain 511 203 623 428 12 a) Infiltration 80 8 80 8 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)591 211 703 435 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -591 -211 214 76 14 Subtotal 0 0 917 512 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 917 512 Air required (cfm)Air required (cfm)0 0 30 35 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Mar-20 14:30:27Right-Suite® Universal 2022 22.0.04 RSU01476 Page 11...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Right-J® Worksheet 02/23/2023Date:Entire House Brian J BennettBy:The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net 1 Room name Bed 2 Bed 3 2 Exposed wall 34.0 ft 20.5 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft14.0x14.5 ft13.5x11.5 5 Room area 203.0 ft²155.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-815B19-0wc-8 0.0690.069 nn 5.005.00 0.000.00 0 0 0 0 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 .GG 4A5-2ovd4A5-2ovd 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 .WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nn 4.204.20 0.800.80 0 0 0 0 0 0 0 0 11 GG 4A5-2ov4A5-2ov 0.3000.300 nn 21.7221.72 10.2110.21 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ee 3.003.00 0.010.01 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ee 4.204.20 0.800.80 126 126 529 101 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ee 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ss 3.133.13 0.020.02 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ss 4.204.20 0.800.80 131 83 346 66 104 75 316 60 GG 4A5-2ov4A5-2ov 0.3000.300 ss 21.7221.72 18.2718.27 48 0 1043 877 28 0 615 518 DD 11D011D0 0.3900.390 ss 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW 15B19-0wc-815B19-0wc-8 0.0690.069 ww 2.992.99 0.020.02 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 ww 4.204.20 0.800.80 50 50 208 40 81 81 340 65 GG 4A5-2ov4A5-2ov 0.3000.300 ww 21.7221.72 33.3333.33 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 WW R-22 Frame WallR-22 Frame Wall 0.0580.058 nwnw 4.204.20 0.800.80 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 nwnw 34.0334.03 25.5925.59 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nwnw 28.2428.24 7.357.35 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.451.45 0.850.85 0 0 0 0 0 0 0 0 FF 21A-28t21A-28t 0.0220.022 --1.591.59 0.000.00 203 203 323 0 155 155 247 0 6 c) AED excursion 164 90 Envelope loss/gain 2449 1248 1518 733 12 a) Infiltration 340 34 205 20 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 1 230 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13)2789 1512 1723 983 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 2789 1512 1723 983 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2789 1512 1723 983 Air required (cfm)Air required (cfm)90 105 56 68 Job #: 02/23/2023 Barber 01 Performed by Brian J Bennett for: Tallman Construction Ammon, Id 83406 Phone: 208-403-5858 Scott@tallmanconstruction.com The Energy Auditor 1810 Curlew Drive Ammon, Id 83406 Phone: 208-721-2524 Brian@theenergyauditor.net Scale: 1 : 95 Page 1 Right-Suite® Universal 2022 22.0.04 RSU01476 2023-Mar-20 14:32:43 ...ion\Barber\Barber Manual J&D.rup N Main Floor Master T Master Bath Master Cl s Laundry Master Bed Mud Office Kit/Live/Dine Pantry Bath 2 Bed 2 Bed 3 35 cfm 73 cfm 73 cfm 73 cfm 73 cfm 36 cfm 68 cfm 52 cfm 52 cfm 50 cfm 36 cfm 80 cfm 4 cfm 29 cfm 62 cfm Job #: 02/23/2023 Barber 01 Performed by Brian J Bennett for: Tallman Construction Ammon, Id 83406 Phone: 208-403-5858 Scott@tallmanconstruction.com The Energy Auditor 1810 Curlew Drive Ammon, Id 83406 Phone: 208-721-2524 Brian@theenergyauditor.net Scale: 1 : 95 Page 2 Right-Suite® Universal 2022 22.0.04 RSU01476 2023-Mar-20 14:32:44 ...ion\Barber\Barber Manual J&D.rup N Basement Bed 4 Bath 3 T cls 4 Bath 3 Bed 6 Linen Family Room Bed 5 Mechanical/ST 96 cfm 9'-0" 1255 cfm 79 cfm 79 cfm 79 cfm 94 cfm 66 cfm 37 cfm 79 cfm 6 " 6 " 6 x 8 6 " 6 " 6 " 6 " 14 x 8 6 " 8 " 6 " 6 " 22 x 8 6 "6 " 6 " 6 " 6 " 6 " 6 " 6 " 6 "6 " 6 " 16 x 810 x 8 8 x 8 6 " 6 x 8 6 " 6 " 6 x 8 10 x 8 6 x 86 x 8 2023-Mar-20 14:30:30 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 1 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Equipment Summary 02/23/2023Date:Entire House Brian J BennettBy: The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net Project Information Tallman ConstructionFor: Ammon, Id 83406 Phone: 208-403-5858 Email: Scott@tallmanconstruction.com Base System: Cooling: Coleman, Unitary Products Group COLEMAN TF4B 2421Coil Model: C(A,C,D,E)30D44+CP9C080B12MP12+TDR Total cooling capacity = 24000 Btuh, 13.2 EER, 17 SEER, Sound Level = 0.0 Heating: Coleman, Unitary Products Group COLEMAN BY JOHNSON CONTROLS CP9C 060B12MP13 Input = 60000 Btuh, Output = 58000 Btuh, 97.5 AFUE Water Heating: Gas conventional40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Features: Investment 1: Cooling: Coil Model: Total cooling capacity = 0 Btuh, 0 SEER, Sound Level = 0.0 Heating:Input = 0 Btuh, Output = 0 Btuh, 80 AFUE Water Heating: Gas conventional 40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Features: 2023-Mar-20 14:30:30 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 2 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Equipment Summary 02/23/2023Date:Entire House Brian J BennettBy: The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net Project Information Tallman ConstructionFor: Ammon, Id 83406 Phone: 208-403-5858 Email: Scott@tallmanconstruction.com Investment 2: Cooling:Coil Model: Total cooling capacity = 0 Btuh, 0 SEER, Sound Level = 0.0 Heating: Input = 0 Btuh, Output = 0 Btuh, 80 AFUE Water Heating: Gas conventional40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Features: Investment 3: Cooling: Coil Model: Total cooling capacity = 0 Btuh, 0 SEER, Sound Level = 0.0 Heating:Input = 0 Btuh, Output = 0 Btuh, 80 AFUE Water Heating: Gas conventional 40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Features: 2023-Mar-20 14:30:30 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 1 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Manual S Compliance Report 02/23/2023Date:Entire House Brian J BennettBy: The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net Project Information Tallman ConstructionFor: Ammon, Id 83406 Phone: 208-403-5858 Email: Scott@tallmanconstruction.com Cooling Equipment Design Conditions °F75.0Entering coil DB:Btuh18131Sensible gain:°F89.4Outdoor design DB: °F61.8Entering coil WB:Btuh1003Latent gain:°F60.8Outdoor design WB: Btuh19134Total gain:°F75.0Indoor design DB: cfm1255Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: TF4B2421+C(A,C,D,E)30D44+CP9C080B12MP12+TDRModel:Coleman, Unitary PrManufacturer: cfm1255Actual airflow: % of load119Btuh21600Sensible capacity: % of load239Btuh2400Latent capacity: %90SHR:% of load125Btuh24000Total capacity: Heating Equipment Design Conditions °F70.0Entering coil DB:Btuh38773Heat loss:°F-2.4Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Gas furnaceEquipment type: CP9C060B12MP13Model:Coleman, Unitary PrManufacturer: cfm1255Actual airflow: °F50Temp. rise:% of load150Btuh58000Output capacity: Meets all requirements of ACCA Manual S. 2023-Mar-20 14:30:30 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 1 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Duct System Summary 02/23/2023Date:Entire House Brian J BennettBy: The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net Project Information Tallman ConstructionFor: Ammon, Id 83406 Phone: 208-403-5858 Email: Scott@tallmanconstruction.com CoolingHeating External static pressure in H2O0.65in H2O0.65 Pressure losses in H2O0.47in H2O0.47 Available static pressure in H2O0.18in H2O0.18 Supply / return available pressure 0.090 / 0.090 in H2O in H2O0.090 / 0.090 Lowest friction rate in/100ft0.053in/100ft0.053 Actual air flow cfm1255cfm1255 Total effective length (TEL) ft337 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st4B280.050.0ShMt0x06.00.0553530512cBath 2 st1230.026.5ShMt0x06.00.07023371148hBath 3 T st4A275.058.5ShMt0x06.00.0545245756cBed 2 st4B270.066.5ShMt0x06.00.0535245756cBed 2-A st4270.044.0ShMt0x06.00.0576856983cBed 3 st2225.042.0ShMt0x06.00.06757662054hBed 4 st1B185.046.0ShMt0x06.00.07879391138cBed 5 st2175.028.0ShMt0x06.00.08994491364cBed 6 st1225.026.0ShMt0x06.00.07279781140cFamily Room st1A230.040.0ShMt0x06.00.06779781140cFamily Room-A st1A220.058.0ShMt0x06.00.06579781140cFamily Room-B st4275.027.0ShMt0x06.00.06073732259hKit/Live/Dine st4A265.058.0ShMt0x06.00.05673732259hKit/Live/Dine-A st4260.038.5ShMt0x06.00.06073732259hKit/Live/Dine-B st4280.023.5ShMt0x06.00.05973732259hKit/Live/Dine-C st5A275.014.0ShMt0x06.00.0623616514cLaundry st5A265.034.5ShMt0x06.00.0605039725cMaster Bath st5270.033.5ShMt0x06.00.05975802470hMaster Bed st5B270.024.5ShMt0x06.00.06124361125hMaster Cls st5C275.045.5ShMt0x06.00.0561629901hMaster T st1215.039.0ShMt0x06.00.07126962954hMechanical/ST st5260.018.0ShMt0x06.00.06540621907hMud st5275.08.0ShMt0x06.00.06404120hOffice 2023-Mar-20 14:30:30 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 2 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st5A Peak AVF 120 126 0.056 377 7.1 6x8 ShtMetl st5 st4 Peak AVF 468 498 0.053 560 12.0 16x8 ShtMetl st3 st4A Peak AVF 193 213 0.053 478 8.8 8x8 ShtMetl st4 st4B Peak AVF 75 88 0.053 263 6.3 6x8 ShtMetl st4A st5C Peak AVF 29 16 0.056 87 4.1 6x8 ShtMetl st5B st5B Peak AVF 66 40 0.056 197 5.6 6x8 ShtMetl st5A st5 Peak AVF 266 240 0.056 478 9.4 10x8 ShtMetl st3 st1A Peak AVF 195 237 0.065 426 8.8 10x8 ShtMetl st1 st1 Peak AVF 405 365 0.065 521 10.7 14x8 ShtMetl st2 Peak AVF 116 152 0.067 435 8.0 0x0 ShtMetl st1B Peak AVF 39 79 0.078 236 5.6 6x8 ShtMetl st1A st3 Peak AVF 734 739 0.053 604 13.9 22x8 ShtMetl Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb1 0x 12550 1255 0 0 0 0x80 ShMt 2023-Mar-20 14:30:30 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 1 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Static Pressure and Friction Rate 02/23/2023Date:Entire House Brian J BennettBy: The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net Project Information Tallman ConstructionFor: Ammon, Id 83406 Phone: 208-403-5858 Email: Scott@tallmanconstruction.com Available Static Pressure CoolingHeating (in H2O)(in H2O) 0.650.65External static pressure Pressure losses 0.190.19Coil 00Heat exchanger 0.030.03Supply diffusers 0.030.03Return grilles 0.160.16Filter 00Humidifier 0.060.06Balancing damper 00Other device 0.180.18Available static pressure Total Effective Length ReturnSupply (ft)(ft) 030Measured length of run-out 037Measured length of trunk 0270Equivalent length of fittings 0337Total length 337Total effective length Friction Rate CoolingHeating (in/100ft)(in/100ft) < 0.060.053< 0.060.053Supply Ducts < 0.060.053< 0.060.053Return Ducts Fitting Equivalent Length Details 4AD=60, 2J0=50, 12R=5, 12R=5, 9K=65, 1F2=85: TotalEL=270Supply TotalEL=0Return 2023-Mar-20 14:30:30 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 1 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 02/23/2023 Barber 01Job:Duct system multi orientation report 02/23/2023Date:Entire House Brian J BennettBy: The Energy Auditor 1810 Curlew Drive, Ammon, Id 83406 Phone: 208-721-2524 Email: Brian@theenergyauditor.net Project Information Tallman ConstructionFor: Ammon, Id 83406 Phone: 208-403-5858 Email: Scott@tallmanconstruction.com Group 1: ( N) Group 2: (NE, SW) Group 3: ( E, SE) Group 4: ( S) Group 5: ( W) Group 6: (NW) Duct Name (SE)(E)(NE)(N) Duct SizeReg SizeReg CFMDuct SizeReg SizeReg CFMDuct SizeReg SizeReg CFMDuct SizeReg SizeReg CFM Supply Branches Bath 2 612x430 h612x430 h612x430 h612x435 c Bath 3 T 612x439 c612x441 c612x437 h612x437 h Bed 2 612x445 h612x447 c612x449 c612x452 c Bed 2-A 612x445 h612x447 c612x449 c612x452 c Bed 3 612x456 h612x460 c612x463 c612x468 c Bed 4 612x485 c612x490 c612x477 c612x466 h Bed 5 612x450 c612x439 h612x443 c612x479 c Bed 6 612x449 c612x449 h612x460 c612x494 c Family Room 712x4113 c712x4115 c612x4104 c612x479 c Family Room-A 712x4113 c712x4115 c612x4104 c612x479 c Family Room-B 712x4113 c712x4115 c612x4104 c612x479 c Kit/Live/Dine 612x473 h612x473 h612x473 h612x473 h Kit/Live/Dine-A 612x473 h612x473 h612x473 h612x473 h Kit/Live/Dine-B 612x473 h612x473 h612x473 h612x473 h Kit/Live/Dine-C 612x473 h612x473 h612x473 h612x473 h Laundry 612x425 c612x423 c612x426 c612x436 c Master Bath 612x439 h612x439 h612x439 h612x450 c Master Bed 712x4129 c712x4138 c712x4113 c612x480 h Master Cls 612x436 h612x436 h612x436 h612x436 h Master T 612x434 c612x437 c612x429 c612x429 h Mechanical/ST 612x496 h612x496 h612x496 h612x496 h Mud 612x462 h612x462 h612x462 h612x462 h Office 612x44 h612x44 h612x44 h612x44 h Supply Trunks st5A 6x8120 h6x8120 h6x8120 h6x8126 c st4 16x8468 h16x8468 h16x8468 h16x8498 c st4A 8x8193 h8x8193 h8x8193 h8x8213 c st4B 6x875 h6x875 h6x875 h6x888 c st5C 6x829 h st5B 6x834 c6x837 c6x829 c6x866 h st5 10x8266 h10x8266 h10x8266 h10x8266 h st1A 6x8162 c6x8142 c6x8147 c10x8237 c st1 14x8445 c14x8429 c14x8407 c14x8405 h st2 7135 c7128 c7137 c8152 c st1B 6x850 c6x839 h6x843 c6x879 c st3 22x8734 h22x8734 h22x8734 h22x8739 c Return Branches rb1 0x832x181255 c0x832x181255 c0x832x181255 c0x832x181255 c Friction Rates Heating FR 0.0530.0530.0530.053 2023-Mar-20 14:30:30 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 2 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S Cooling FR 0.0530.0530.0530.053 st2A 649 c649 h660 c 2023-Mar-20 14:30:30 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 3 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S Project Information Tallman ConstructionFor: Ammon, Id 83406 Phone: 208-403-5858 Email: Scott@tallmanconstruction.com Duct Name (NW)(W)(SW)(S) Duct SizeReg SizeReg CFMDuct SizeReg SizeReg CFMDuct SizeReg SizeReg CFMDuct SizeReg SizeReg CFM Supply Branches Bath 2 612x430 h612x430 h612x430 h612x440 c Bath 3 T 612x437 h612x437 h612x437 h612x437 h Bed 2 612x465 c612x467 c612x450 c612x445 h Bed 2-A 612x465 c612x467 c612x450 c612x445 h Bed 3 612x482 c612x484 c612x464 c612x456 h Bed 4 612x468 c612x482 c612x479 c612x476 c Bed 5 612x458 c612x443 c612x463 c612x484 c Bed 6 612x457 c612x449 h612x449 h612x469 c Family Room 612x489 c612x499 c612x499 c612x4100 c Family Room-A 612x489 c612x499 c612x499 c612x4100 c Family Room-B 612x489 c612x499 c612x499 c612x4100 c Kit/Live/Dine 612x473 h612x473 h612x473 h612x473 h Kit/Live/Dine-A 612x473 h612x473 h612x473 h612x473 h Kit/Live/Dine-B 612x473 h612x473 h612x473 h612x473 h Kit/Live/Dine-C 612x473 h612x473 h612x473 h612x473 h Laundry 612x429 c612x425 c612x427 c612x432 c Master Bath 612x439 h612x439 h612x439 h612x439 h Master Bed 612x497 c712x4123 c712x4117 c712x4109 c Master Cls 612x436 h612x436 h612x436 h612x436 h Master T 612x429 h612x432 c612x430 c612x429 h Mechanical/ST 612x496 h612x496 h612x496 h612x496 h Mud 612x462 h612x462 h612x462 h612x462 h Office 612x44 h612x44 h612x44 h612x44 h Supply Trunks st5A 6x8120 h6x8120 h6x8120 h6x8120 h st4 16x8515 c16x8503 c16x8475 c16x8468 h st4A 10x8225 c8x8218 c8x8199 c8x8193 h st4B 6x890 c6x884 c6x879 c6x875 h st5C st5B 6x829 h6x832 c6x830 c6x829 h st5 10x8266 h10x8266 h10x8266 h10x8266 h st1A 10x8237 c10x8241 c6x8162 c8x8184 c st1 14x8405 h14x8405 h14x8414 c14x8441 c st2 7125 c7116 h7123 c8145 c st1B 6x858 c6x843 c6x863 c6x884 c st3 22x8753 c22x8748 c22x8734 h22x8734 h Return Branches rb1 0x832x181255 c0x832x181255 c0x832x181255 c0x832x181255 c Friction Rates Heating FR 0.0530.0530.0530.053 Cooling FR 0.0530.0530.0530.053 st2A 657 c649 h649 h669 c 2023-Mar-20 14:30:30 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 4 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S Project Information Tallman ConstructionFor: Ammon, Id 83406 Phone: 208-403-5858 Email: Scott@tallmanconstruction.com Duct Name SmalestLargest Duct SizeReg SizeReg CFMDuct SizeReg SizeReg CFM Supply Branches Bath 2 612x430 h612x440 c Bath 3 T 612x437 h612x441 c Bed 2 612x445 h612x467 c Bed 2-A 612x445 h612x467 c Bed 3 612x456 h612x484 c Bed 4 612x466 h612x490 c Bed 5 612x439 h612x484 c Bed 6 612x449 h612x494 c Family Room 612x479 c712x4115 c Family Room-A 612x479 c712x4115 c Family Room-B 612x479 c712x4115 c Kit/Live/Dine 612x473 h612x473 h Kit/Live/Dine-A 612x473 h612x473 h Kit/Live/Dine-B 612x473 h612x473 h Kit/Live/Dine-C 612x473 h612x473 h Laundry 612x423 c612x436 c Master Bath 612x439 h612x450 c Master Bed 612x480 h712x4138 c Master Cls 612x436 h612x436 h Master T 612x429 h612x437 c Mechanical/ST 612x496 h612x496 h Mud 612x462 h612x462 h Office 612x44 h612x44 h Supply Trunks st5A 6x8120 h6x8126 c st4 16x8468 h16x8515 c st4A 8x8193 h10x8225 c st4B 6x875 h6x890 c st5C 0x00 h6x829 h st5B 6x829 c6x866 h st5 10x8266 h10x8266 h st1A 6x8142 c10x8241 c st1 14x8405 h14x8445 c st2 7116 h8152 c st1B 6x839 h6x884 c st3 22x8734 h22x8753 c Return Branches rb1 0x832x181255 c0x832x181255 c Friction Rates Heating FR 0.0530.053 Cooling FR 0.0530.053 st2A 00 h669 c 2023-Mar-20 14:30:30 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 5 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S Background Color Legend Yellow background Duct Size - duct size is smaller than the largest duct size in the row Reg Size - register size is smaller than the largest register size in the row Reg CFM - register design cfm is larger than 150 CFM Friction Rate - friction rate is outside ACCA Manual-D recommended range (0.06 - 0.18) Pink background column header Largest coolling load orientation 2023-Mar-20 14:30:32 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 1 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S ENERGY STAR Single-Family New Homes National HVAC Design Report, Version 3 / 3.1(Rev. 11) HVAC Designer Responsibilities: • Complete one National HVAC Design Report for each system design for a house plan, created for either the specific plan configuration (i.e., elevation, option, orientation, & county) of the home to be certified or for a plan that is intended to be built with different configurations (i.e., different elevations, options, and/or orientations). Visit www.energystar.gov/newhomeshvacdesign and see Footnote 2 for more information. • Obtain efficiency features (e.g., window performance, insulation levels, and infiltration rate) from the builder or Rater. ³ • Provide the completed National HVAC Design Report to the builder or credentialed HVAC contractor and to the Rater. 1. Design Overview 1.1 Designer name: Brian J Bennett 02/23/2023Date:The Energy AuditorDesigner company: 1.2 Select which party you are providing these design services to: Credentialed HVAC contractororBuilder 1.3 Name of company you are providing these design services to (if different than Item 1.1): Tallman Construction 1.4 Area that system serves: Whole-house OtherLower-levelUpper-level 1.5 Is cooling system for a temporary occupant load? NoYes 1.6 House plan: Check box to indicate whether the system design is site-specific or part of a group: Site-specific design. Option(s) & elevation(s) modeled: Configuration modeled:total groups for this house plan.0out of0Group design. Group #: Designer 2. Dwelling Unit Mechanical Ventilation System Design (“Vent System”) & Inlets in Return Duct Verified Airflow: 2.1 Ventilation airflow design rate & run-time meet the requirements of ASHRAE 62.2-2010, 2013 or 2016 -CFM02.2 Ventilation airflow rate required by 62.2 for a continuous system: -minutes0Cycle time:minutes0Run-time per cycle:CFM2.3 Design for this system: Vent. airflow rate: System Type & Controls: -BalancedExhaustSupply2.4 Specified system type: -(e.g., Master bath, utility room)2.5 Specified control location: 2.6 Specified controls allow the system to operate automatically, without occupant intervention. 2.7 Specified controls include a readily-accessible ventilation override and a label has also been specified if its function is not obvious (e.g., a label is required for a toggle wall switch, but not for a switch that’s on the ventilation equipment). 2.8 For any outdoor air inlet designed to connect to a ducted return of the HVAC system, specified controls automatically restrict airflow using a motorized damper during ventilation off-cycle and occupant override. Sound:2.9 The fan of the specified system is rated ≤ 3 sones if intermittent and ≤ 1 sone if continuous, or exempted Efficiency: 2.10 If Vent System controller operates the HVAC fan, then HVAC fan operation is intermittent and either the fan type in Item 4.7 is ECM / ICM or the controls will reduce the run-time by accounting for HVAC system heating or cooling hours. 2.11 If bathroom fans are specified as part of the system, t hen they are ENERGY STAR certified Air Inlet Location:(Complete this section if system has a specified air inlet location; otherwise check “N/A”) N/A 2.12 Inlet pulls ventilation air directly from outdoors and not from attic, crawlspace, garage, or adjacent dwelling unit 2.13 Inlet is ≥ 2 ft. above grade or roof deck; ≥ 10 ft. of stretched-string distance from known contamination sources (e.g., stack, vent, exhaust, vehicles) not exiting the roof, and ≥ 3 ft. from known sources exiting the roof 3. Room-by-Room Heating & Cooling Loads 3.1 Room-by-room loads calculated using: Unabridged ACCA Manual J v8 2013 ASHRAE Fundamentals Other per AHJ - 3.2 Indoor design temperatures used in loads are 70°F for heating and 75°F for cooling 3.3 Outdoor design temperatures used in loads: (See Footnote 13 and energystar.gov/hvacdesigntemps) - °F-2Heating season:°F89Cooling season:Bonneville, IDCounty & State, or US Territory, selected: 3.4 Number of occupants used in loads: 7 - 3.5 Conditioned floor area used in loads: 4691 -Sq. Ft. 3.6 Window area used in loads: 579 -Sq. Ft. 3.7 Predominant window SHGC used in loads: 0.31 - 3.8 Infiltration rate used in loads: 0.05Summer:-0.10Winter: 3.9 Mechanical ventilation rate used in loads: 0 -CFM Loads At Design Conditions (kBtuh) NEN -NWWSWSSEE -22.723.421.317.122.926.525.219.43.10 Sensible heat gain (By orientation) -1.03.11 Latent heat gain (Not by orientation)Cooling -23.724.422.318.123.927.526.220.43.12 Total heat gain (By orientation) Variation is ≤ 6 kBtuhkBtuh9.43.13 Maximum – minimum total heat gain (Item 3.12) across orientations = Heating 3.14 Total heat loss (Not by orientation) 38.8 - 2023-Mar-20 14:30:32 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 2 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S ENERGY STAR Single-Family New Homes National HVAC Design Report, Version 3 / 3.1(Rev. 11) Designer 4. Heating & Cooling Equipment Selection Verified 4.1 Equipment selected per ACCA Manual S (see Footnote 25 & 26). Air Conditioner / Heat Pump (Complete if air conditioner or heat pump will be installed; otherwise check “N/A”)N/A 4.2 Equipment type:-Cooling & heating heat pumpCooling-only air conditioner or 4.3 Condenser manufacturer & model: Coleman, Unitary Products Group TF4B2421 - 4.4 Evaporator / fan coil manufacturer & model: Coleman, Unitary Products Group C(A,C,D,E)30D44+CP9C080B12MP12+TDR - 4.5 AHRI reference #: 8713065 - 4.6 AHRI listed efficiency: EER / SEER Air-source heat pump: Ground-source heat pump: -COPHSPF17/13.2 4.7 Evaporator fan type: PSC -Other:ECM / ICM 4.8 Compressor type: Single-speed -Variable-speedTwo-speed 4.9 Latent capacity at design conditions, from OEM expanded performance data: -kBtuh0 4.10 Sensible capacity at design conditions, from OEM expanded performance data: -kBtuh0 4.11 Total capacity at design conditions, from OEM expanded performance data: -kBtuh0 4.12 Air-source heat pump capacity: kBtuh0At 17°F:-N/AkBtuh0At 47°F: 4.13 Cooling sizing % = Total capacity (Item 4.11) divided by maximum total heat gain (Item 3.12): -%0 4.14 Complete this Item if Condition B Climate will be used to select sizing limit in Item 4.15. Otherwise, check “N/A”: -N/A -%96=4.14.1 Load sensible heat ratio = Max. sensible heat gain (Item 3.10) / Max. total heat gain (Item 3.12) -4.1=4.14.2 HDD / CDD ratio (Visit energystar.gov/hvacdesigntemps to determine this value for the design location) 4.15 Check box of applicable cooling sizing limit from chart below:- Equipment Type (Per Item 4.2) & Compressor Type (Per Item 4.8) Climate Condition (Per Item 4.14)Single-Speed Variable-SpeedTwo-Speed For Cooling-Only Equipment or For Cooling Mode of Heat Pump in Recommended: 90 – 115% Recommended: 90 – 120% Recommended: 90 – 130% Condition A Climate Allowed: 90 – 160%Allowed: 90 – 140%Allowed: 90 – 130% For Cooling Mode of Heat Pump in 90% - 100%, plus 15 kBtuh 90% - 100%, plus 15 kBtuh 90% - 100%, plus 15 kBtuhCondition B Climate 4.16 Cooling sizing % (4.13) is within cooling sizing limit (4.15) Furnace (Complete if furnace will be installed; otherwise check “N/A”)N/A 4.17 Furnace manufacturer & model: Coleman, Unitary Products Group CP9C060B12MP13 - 4.18 Listed efficiency:-AFUE97.5 4.19 Total capacity:-kBtuh58 4.20 Heating sizing % = Total capacity (Item 4.19) divided by total heat loss (Item 3.14): -%150 4.21 Check box of applicable heating sizing limit from chart below:- When Used for Heating Only When Paired With Cooling Recommended: 100 – 140% Allowed: 100 – 400%100 - 140% 4.22 Heating sizing % (4.20) is within heating sizing limit (4.21) 5. Duct Design (Complete if heating or cooling equipment will be installed with ducts; otherwise check “N/A”)N/A 5.1 Duct system designed for the equipment selected in Section 4, per ACCA Manual D 5.2 Design HVAC fan airflow:-CFM1255Heating modeCFM1255Cooling mode 5.3 Design HVAC fan speed setting (e.g., low, medium, high): Heating mode MediumMediumCooling mode - 5.4 Design total external static pressure (corresponding to the mode with the higher airflow in Item 5.2): -IWC0.65 5.5 Room-by-room design airflows documented below (which must sum to the mode with the higher airflow in Item 5.2) - Room Name Design AirflowRoom NameDesign AirflowRoom NameDesign Airflow (CFM)(CFM)(CFM) 1 2312 36Laundry35Bath 2 2 2413 0Linen0Bath 3 3 2514 50Master Bath23Bath 3 T 4 2615 75Master Bed105Bed 2 5 2716 24Master Cls68Bed 3 6 2817 16Master T57Bed 4 7 2918 26Mechanical/ST79Bed 5 8 3019 40Mud94Bed 6 9 3120 0Office0cls 4 10 3221 0Pantry237Family Room 11 1255Total for all rooms22290Kit/Live/Dine ANSI / RESNET / ACCA 310 HVAC Design Report (1,2) 2023-Mar-20 14:30:34 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 1 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 1. Design Basis & Architectural Scope 1.1 Design description (optional): 1.2 Design company: The Energy Auditor 02/23/2023Date:Brian J BennettDesigner name: 1.3 Software name and version used to complete design: Right-Suite® Universal 2022 22.0.04 RSU01476 N/A For a Dwelling,Townhouse, or Dwe lling / Sleeping Unit Within (i.e. duplex): 1.4 Architectural plan name or address of property: 1.5 Architectural options used in the design(3): 1.6 Other architectural options that the design can be used with:(4) For a Dwelling / Sleeping Unit Not Within a Dwelling or Townhouse (e.g. condo, apartment): 1.7 Unique ID for bldg. that the dwelling / sleeping unit is in:(5) 1.8 Architectural plan used in design (e.g. dwelling unit model): 1.9 Other architectural plans that the design can be used with:(6) 1.10 Architectural options used in the design:(3) 1.11 Other architectural options that the design can be used with:(4) 1.12 Dwelling / sleeping unit location used in design:(7) 2. Dwelling-Unit Mechanical Ventilation System Design Ventilation System Type & Control Location:System 1 System 2System 2 2.1 Unique name or ID for each system:(8) 2.2 Vent. equipment manufacturer & model #:(9) 2.3 Specified system type:(10)Balanced w/o Recovery 2.4 Specified control location:(11 ) 2.5 Ventilation zone name(s) served by system:(12)Entire House Ventilation Zone Served by Ventilation System:Zone 1 Zone 3Zone 2 2.6 Ventilation zone name:(12)Entire House 2.7 Design basis:(13)Other 2.8 Floor area (sq. ft.) and # bedrooms in vent. zone: 04691 2.9 Ventilation design airflow rate (CFM ):(14) 2.10 Vent. runtime per cycle & cycle time (mins): 0 of every 0 2.11 Time-averaged mechanical vent. rate (CFM ):(15) 3. Heat Gain & Heat Loss Loads 3.1 Design basis for the loads:(16)ACCA Manual J 8th Edition 3.2 Load methodology:(17)Room-by-Room 3.3 Indoor design temperatures used in loads (°F):70Heating Season: 75Cooling Season: 3.4 Outdoor design temperatures used in loads (°F):(18)-2Heating Season: 89Cooling Season: 3.5 Outdoor design temperature location & data source:(19)Bonneville, ID ASHRAE 2009Data Source: Zone-Specific Inputs & Loads at Desi gn Conditions Zone 2Zone 1 Zone 3 3.6 Name of heated or cooled zone:(20)Entire House 3.7 Occupants & total occup. internal gains (Btuh):(21)16107 3.8 Total non-occupant internal gains (Btuh): 1700 3.9 Conditioned floor area (sq. ft.):(22)4691 3.10 Window area (sq. ft.):(23)579 3.11 Predominant window SHGC:(24)0.3 3.12 Predominant insulation nominal R-value:(24,25)Wall:50.0Ceiling:22.0Wall: Ceiling:Wall:Ceiling: 3.13 Infiltration rate (Qualitative or ACH50):(26)Tight 3.14 Time-averaged mechanical vent. rate (CFM ):0 3.15 Heat gain (kBtuh):(27)TotalLatentSensibleTotalLatentSensibleTotalLatentSensible 20.41.019.4N 26.21.025.2NE 27.51.026.5E 23.91.022.9SE 18.11.017.1S 22.31.021.3SW 24.41.023.4W 23.71.022.7NW 3.16 Maximum – minimum total heat gain (kBtuh):(28)9.4 3.17 Total heat loss (kBtuh): 38.8 ANSI / RESNET / ACCA 310 HVAC Design Report (1,2) 2023-Mar-20 14:30:34 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 2 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 4. Heating & Cooling Equi pment Selection 1 32 Air Conditioners, Heat Pumps, & Other Cooling Equipment (If none of these will be installed, check “N/A”)N/A 4.1 Unique name or ID for each system: Entire House 4.2 Zone that system serves (See Item 3.6): Entire House 4.3 Equipment type:(29)AC 4.4 Evaporator / fan coil mfr. & model #:(30)COLU C(A,C,D,E)30D44 4.5 Condenser mfr. & model #:(30)COLU TF4B2421 N/A N/AN/A 4.6 AHRI ref. #, or check box for alt. OEM doc.:(31)OEM8713065 OEMOEM 4.7 If AC / HP, rated cooling efficiency:(32)N/A17 SEER N/AN/A 4.8 If HP, rated heating efficiency:(33)N/AN/AN/A 4.9 If HP, ratio of max. to min. rated capacity:N/A N/AN/A 4.10 If AC / HP, blower fan motor & speed type:(34)N/ASingleECM/ICM N/AN/A 4.11 If AC / HP, compressor speed type:(35)N/AVariable N/AN/A 4.12 If AC / HP, meter device type:(36)N/AN/AN/A 4.13 If TXV or EEV, OEM subcooling target (°F):(37)N/A0.0 N/AN/A 4.14 Filter performance metric and rating:(38)N/A N/AN/A Furnaces, Boilers, & Other Heating Equipment (If none of these will be installed, check “N/A”)N/A 4.15 Unique name or ID for each system: Entire House 4.16 Zone that system serves (See Item 3.6): Entire House 4.17 Equipment type:(39)Furnace 4.18 Equipment manufacturer & model #: COLU CP9C060B12MP13 4.19 AHRI ref. #, or check box for alt. OEM doc.:(31)OEM204829753 OEMOEM 4.20 If furnace or boiler, rated heating efficiency:N/A97.5 AFUE N/AN/A 4.21 If furnace, blower fan motor & speed type:(34)N/ASingleECM/ICM N/AN/A 4.22 If furnace or boiler, heating capacity type:(40)N/ASingle Stage N/AN/A 4.23 If furnace or boiler, venting type:(41)N/A N/AN/A 4.24 Filter performance metric and rating:(38)N/A N/AN/A 5. Duct Design (Complete if duct system will be installed; otherwise check “N/A”)N/A 5.1 Unique name or ID for each system: Entire House 5.2 Zone that system serves (See Item 3.6): Entire House Design Values for Cooling and Heating Mode HeatingCooling HeatingCoolingHeatingCooling 5.3 Design blower fan airflow (CFM ):(42)12551255 5.4 Design blower fan speed setting:(43)MediumMedium 5.5 Design external static pressure (IWC):(44)0.65 5.6 Room-by-room design airflows (CFM ): Room Name AirflowRoom NameAirflowRoom NameAirflow Total Design Airflow: 1255 [All rooms][All rooms][All rooms] 1. 35Bath 2 2. 0Bath 3 3. 23Bath 3 T 4. 105Bed 2 5. 68Bed 3 6. 57Bed 4 7. 79Bed 5 8. 94Bed 6 9. 0cls 4 10. 237Family Room 11. 290Kit/Live/Dine 12. 36Laundry 13. 0Linen 14. 50Master Bath 15. 75Master Bed 16. 24Master Cls 17. 16Master T 18. 26Mechanical/ST 19. 40Mud 20. 0Office ANSI / RESNET / ACCA 310 HVAC Design Report (1,2) 2023-Mar-20 14:30:34 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 3 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 5.6 Room-by-room design airflows (Continued):Airflow Room NameRoom Name AirflowRoom NameAirflow 21. 0Pantry 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. Footnotes 1. The purpose of this report is to document the design information required by ANSI / RESNET / ACCA 310 – a standard for grading the installation of HVAC systems - for a dwelling, townhouse, or dwelling / sleeping unit.The HVAC designer should complete one reportper dwelling, townhouse, or dwelling / sleeping unit that encompasses all HVAC systems(e.g., for a dwelling with two zones, the HVAC system for each zone should be documented in the same report). 2. Note that this report will be reviewed by users of the st andard (e.g., a rater) to ensure that the design meets the tolerances defined in Section 4.3 of ANSI / RESNET / ACCA 310. The HVAC systems will not be eligible to earn recognition for proper installation unless alltolerances are met. 3. If the HVAC design documented in this report incorporated one or more options (e.g., media room option), then list those options. 4. If this same HVAC design could be used with other options (e.g., bonus room, balcony with sliding glass door), then list those option(s). 5. For example, the name of the development or the building’s address. 6. If this same HVAC design could be used with other plans (e.g., other dwelling unit models) in the building, then list those plan(s). 7. Because the loads are dependent on the dwelling / sleeping unit’s location in the building, indicate whether the design is for the TopFloor, a Mid-Level-Floor, or the Bottom-Floor of the building; and either a Corner Unit or Middle Unit that is between two other units. 8. For example, the unique ID might be “Powder Bath Fan” or “Whole-House ERV”. 9. The ventilation equipment manufacturer and model number are required to be reported for dwelling / sleeping units not within a dwelling or townhouse;and are optional for dwellings, townhouses, and sleeping / dwelling units within(i.e., duplex). 10. Ventilation system types are: Supply - a supply-only system, Exhaust - an exhaust-only system, Balanced w/o Recov. - a balanced system wit hout energy or heat recovery, ERV - an energy recovery ventilator, HRV - a heat recovery ventilator, Vent.Dehumidifier - a ventilation system with integrated dehumidifier, or Other - any other system type. 11. For example, common ventilation control locations include a bathroom or utility room. 12. For example, the ventilation zone name may be “Whole Dwelling”, “Upper Level”, “Lower Level”, or “Basement”. 13. Design basis options are: 62.2-2010 - ASHRAE 62.2-2010, 62.2-2013 - ASHRAE 62.2-2013, 62.2-2016 - ASHRAE 62.2-2016, 62.2-2019 - ASHRAE 62.2 - 2019, or Other - any other ventilation standard. 14. Enter the airflow rate of the ventilation system when operating (e.g., a 50 CFM cycled bath fan has a ventilation airflow rate of 50 CFM). 15. The following formula shall be used to determine the time-averaged ventilation airflow rate: Time Averaged Vent Rate = Vent Rate * Runtime Per Cycle / Cycle Time Where : • Time Averaged Vent Rate = The time - averaged ventilation airflow rate. • Vent Rate = The design’s ventilation airflow rate reported in Item 2.9. • Runtime Per Cycle = The runtime per cycle reported in Item 2.10. • Cycle Time = The cycle time reported in Item 2.10. 16. Design basis options for the heat gain and heat loss loads are: ACCA Manual J v8 2013 - ACCA Manual J v8, 2013 edition; ACCA Manual J v8 2016 - ACCA Manual J v8, 2016 edition; 2017 ASHRAE Fund. - 2017 ASHRAE Fundamentals; or Per AHJ - a design basis prescribed by the Authority Having Jurisdiction. 17. Load methodology options are: Room-by-Room or Single Block. Note that for dwellings, townhouses, and dwelling / sleeping units within(i.e., duplex), the room - by - room load methodology must be used.See Fn. 2 for details. 18. Note that the outdoor design temperatures must meet the limits defined in ANSI / RESNET / ACCA 310 Appendix A for the county or U.S.Territory where the project will be constructed.See Fn. 2 for details. 19. The location shall include the city or weather station and the state. The data source options are: ACCA - ACCA Manual J, ASHRAE - ASHRAE Handbook of Fundamentals, or AHJ - design conditions prescribed by the Authority Having Jurisdiction. 20. For example, the heated or cooled zone name may be “Upper Level”, “Master Suite”, or “Basement”. ANSI / RESNET / ACCA 310 HVAC Design Report (1,2) 2023-Mar-20 14:30:34 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 4 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S 21. To determine the number of occupants, calculate the number of bedrooms in the zone and add one. ANSI / RESNET / ACCA 310 defines a “bedroom” for one - and two - family dwellings and townhouses as a room or space 70 square feet of floor area or greater, with egress window or skylight, and doorway to the main body of the dwelling unit, that can be used for sleeping.For all other Dwelling Units, a room or space that can be used for sleeping.For all dwelling or sleeping units, the number of bedrooms shall not be less than one.ANSI / RESNET / ACCA 310 defines an “egress window” as an operable window that provides for a means of escapeand access for rescue in the event of an emergencyand with the following attributes : • Has a sill height of not more than 44 inches above the floor;and, • Has a minimum net clear opening of 5.7 sq.ft., opening height of 24 in., and opening width of 20 in.;and, • Is operational from the inside of the room without the use of keys, tools or special knowledge. The number of occupants must fall within the tolerance specified in ANSI / RESNET / ACCA 310. See Fn. 2 for details. 22. The difference between the Conditioned Floor Area (CFA) used in the design and the actual dwelling, townhouse, or dwelling / sleeping unit must fall within the tolerance specified in ANSI / RESNET / ACCA 310. See Fn. 2 for details.Be advised, the CFA will be evaluated using the definition in ANSI / RESNET / ACCA 310, which defines this value, in part, as the floor area of the Conditioned Space Volume within a building or dwelling unit, not including the floor area of attics, crawlspaces, and basements below air sealed and insulated floors. 23. The difference between the window area used in the design and the actual dwelling, townhouse, or dwelling / sleeping unit must fall within the tolerance specified in ANSI / RESNET / ACCA 310. See Fn. 2 for details.Be advised, the window area will be evaluated by calculating it using the on - site inspection protocol provided in Normative Appendix B of ANSI / RESNET / ICC 301, which instructs the user to measure the widthand height of the rough opening for the windowand round to the nearest inch, and then to use these measurements to calculate window area, rounding to the nearest tenth of a square foot.See https ://codes.iccsafe.org/content/chapter/16191/ for the complete protocol. 24. “Predominant” is defined as the SHGC or R-value used in the greatest amount of window, wall, or ceiling area in the zone. 25. If both cavity and continuous insulation are used, report the sum of the nominal R-value of the cavity and continuous insulation. 26. The infiltration rate shall be reported using a qualitative input (i.e., Tight, Semi-Tight, Average, Semi-Leaky, Leaky) or in units of ACH50. 27. Provide loads for the orientation(s) that the design is intended to be used in (e.g., N, S, E, W), where orientation is defined as the direction that the front door of the dwelling is facing.For example, if a site - specific design has been completed for a single project, only the loads for the single orientation of that project need to be provided. 28. If the heat gain has been provided for multiple orientations, then the difference between the max. and min. total heat gain across the orientations specified must be reported and fall within the tolerance specified in ANSI / RESNET / ACCA 310. See Fn. 2 for details. 29. Equipment type options are: AC - Air Conditioner, HP - Heat Pump, MNAC - Mini-Split Air Conditioner, MNHP - Mini-Split Heat Pump, MTAC - Multi - Split Air Conditioner, MTHP - Multi - Split Heat Pump, and Other - any other cooling equipment type. 30. For single-package systems or systems wit hout a condenser (e.g., evaporative cooler), provide manufacturer and model number in Item 4.4 and select “N / A” for Item 4.5. 31. If an AHRI Reference Number is not available, OEM-provided documentation shall be collected with the rated efficiency of the equipment.If the equipment contains multiple components, the rated efficiency shall reflect the specific combination of indoorand outdoor components, along with confirmation from the OEM that the two components are designed to be used together. 32. For example, if the metric for the rated efficiency of the equipment is SEER, then its SEER rating shall be reported; if the metric is EER, then its EER rating shall be reported; if both SEERand EEER, then both rated values shall be reported. 33. For example, if the metric for the rated efficiency of the equipment is HSPF, then its HSPF rating shall be reported; if the metric is COP, then its COP rating shall be reported; if both HSPFand COP, then both rated values shall be reported. 34. Blower fan motor type options are: PSC - Permanent Split Capacitor, ECM - Electronically Commutated Motor, or Other - any other motor type.For blower fan speed type, while equipment typically has multiple speed settings to select from during installation, this parameter is related to the number of operational speeds that the blower fan is capable of : Single - a system that operates at no more than one speed setting each for heating modeand cooling mode, Two - a system that can operate at no more than two speeds each for heating modeand cooling mode, Variable - a system that can operate at more than two speeds. 35. The compressor speed type is related to the number of operational speeds that the compressor is capable of: Single - a system that operates at no more than one speed setting each for heating modeand cooling mode, Two - a system that can operate at no more than two speeds each for heating modeand cooling mode, Variable - a system that can operate at more than two speeds. 36. Meter device type options are: Piston/Cap - piston / capillary tube, TXV - thermal expansion valve, or EEV - electronic expansion valve. 37. If the meter device type is TXV or EEV, then provide then the OEM-specified subcooling target at the service valve. 38. For example, MERV or FPR. 39. Equipment type options are: Furnace, Boiler, or Other - any other heating equipment type. 40. Heating capacity type options are: Single-Stage, Two-Stage, or Modulating. 41. Vent. type options are: Natural Draft - natural draft system, Mech. Draft - mechanical draft system, or Direct Vent - direct-vent appliance. 42. Provide design airflow in cubic feet per minute of air with a density of 0.075 pounds per cubic feet. Airflow at this air density is often referred to as Standard CFM(SCFM) and represents air at 68 °F, 50 % relative humidity, and at a barometric pressure of 29.92" Hg. 43. This is the OEM setting that corresponds with the design blower fan airflow. Common examples include low, medium-low, medium, medium - high, and high, but also may be defined in terms of dip - switch settings or other classifications ENERGY STAR Single-Family New Homes, All Versions (Rev. 11) 2023-Mar-20 14:30:36 Right-Suite® Universal 2022 22.0.04 RSU01476 Page 1 ...llman Construction\Barber\Barber Manual J&D.rup Calc = MJ8 Front Door faces: S ENERGY STAR Multifamily New Construction, All Versions (Rev. 02) National HVAC Design Supplement to Std. 310 for Dwellings & Units 1. Design Basis 1.1 Design description (optional): 1.2 Designer company: The Energy Auditor 02/23/2023Date:Brian J BennettDesigner name: 2. Dwelling Unit Mechanical Ventilation System Design (“Vent System”) Inlets in Return Duct N/AVerified Airflow: 2.1 Ventilation airflow design rate & run-time for each Vent System meets ASHRAE 62.2-2010 or later edition. 2.2 Access point is specified for Rater to measure ventilation airflow rate and inspect any motorized / shutoff dampers. System Controls: 2.3 Specified controls for each Vent System allow it to operate automatically, without occupant intervention. 2.4 Specified controls for each Vent System include a readily-accessible override & a label has also been specified if its function is not obvious (e.g., a label is required for a toggle wall switch, but not for a switch that’s on the vent. equip.). 2.5 For any outdoor air inlet designed to connect to a ducted return of the HVAC system, specified controls automatically restrict airflow using a motorized damper during ventilation off-cycle and occupant override. Sound:2.6 Specified fan of each Vent System is rated ≤ 3 sones if intermittent and ≤ 1 sone if continuous, or exempted. Efficiency:(Com plete if Vent System controller operates HVAC fan or Vent System uses bath fans; otherwise, check “N/A”) 2.7 If Vent System controller operates the HVAC fan, then HVAC fan operation is intermittent and either fan type in HVAC design report is ECM or controls will reduce the run-time by accounting for HVAC system heating or cooling hours. 2.8 If bathroom fans are specified as part of any Vent System, then they are ENERGY STAR certified. 2.9 MFNC Only: If central exhaust fans are specified as part of the Vent System, then if ≤ 1 HP, they are direct - drive, ECM, with variable speed controllers; and if > 1 HP, they are specified with NEMA PremiumTM Motors or equivalent. Air Inlet Location:(Com plete this section if system has a specified air inlet location; otherwise check “N/A”) 2.10 Inlet(s) pull ventilation air directly from outdoors and not from attic, crawlspace, garage, or adjacent dwelling unit. 2.11 Inlet(s) are ≥ 2 ft. above grade or roof deck; ≥ 10 ft. of stretched-string distance from known contamination sources (e.g., stack, vent, exhaust, vehicles) not exiting the roof, and ≥ 3 ft. from known sources exiting the roof. 2.12 Inlet(s) are provided with rodent / insect screen with ≤ 0.5 inch mesh. 3. Dwelling Unit Local Mechanical Exhaust Design 3.1 System(s) are designed that mechanically exhaust air from each dwelling unit kitchen and bathroom directly to the outdoors or to ventilation risers and meet the requirements in Table 1. Kitchens:Runtime:Multiple UnitsSingle UnitDwelling Units Served by Fan:IntermittenContinuous Bathrooms:Runtime:Multiple UnitsSingle UnitDwelling Units Served by Fan:IntermittenContinuous 4. Heating Equi pment, Cooling Equi pment, & Equi pment Controls Selection 4.1 MFNC Only: If using Prescriptive Path, equipment serving dwelling units meet the efficiency levels specified in Exhibit X of the National Rater Field Checklist, have programmable thermostatic controls, & do not use electric resistance heating. 4.2 MFNC Only: Thermostatic controls for systems serving a dwelling unit are within the unit and not located on exterior walls. If more than one system provides heating or cooling to the same space, controls prevent simultaneous operation. Air Conditioners & Heat Pumps If none will be installed, check N/A 21 3 4.3 Unique name or ID for each system: Entire House 4.4 Maximum sensible and total heat gain load of zone served (kBtuh): 18.117.1 4.5 Sensible, latent, & total cooling capacity at design conditions (kBtuh):0.00.00.0 4.6 If HP, heating capacity at 17°F and at 47°F (kBtuh):N/A N/AN/A 4.7 Compressor speed type: Variable 4.8 Cooling sizing % & a pplicable sizing limit key from Table 2: C10.0 4.9 If C2 chosen in Item 4.8, load sensible heat ratio & HDD / CDD ratio:N/AN/A N/A 4.10 Affirm that cooling sizing % is within cooling sizing limit (4.8): Furnaces 321If none will be installed, check N/A 4.11 Unique name or ID for each system: Entire House 4.12 Total heat loss load of zone served (kBtuh): 38.8 4.13 Total heating capacity (kBtuh):58 4.14 Heating sizing % & a pplicable sizing limit key from Table 3: H2149.6 4.15 Affirm that heating sizing % is within heating sizing limit (4.14): 5. Duct Design 5.1 All duct requirements in Table 4 have been included in the design, where applicable.