HomeMy WebLinkAboutENGINEER LETTER - 23-00396 - Starbucks - New Commercial Bldg - Shell Only651 W. Galena Park Blvd / Draper, UT 84020 / T (801) 990-1775 / www.vectorse.com
Project Number: U1477.009.221
September 12th, 2023
The Richardson Design Partnership, LLC
Attn: Jason Van Noord
510 S. 600 E.,
Salt Lake City, UT 84102
REFERENCE: Starbucks - Rexburg, ID
Gridline B/4 HD19 Alternate
Dear Jason:
Per your request, we have reviewed the calculations and drawings for the above referenced project. Please be advised
as follows:
- It has been requested to change from a single HD19 holdown, to multiple holdowns utilizing 1” diameter
rods at gridline B/4.
- It is our understanding that this corner has a rebar cage with at least (4) #4 verts around this corner
- It is permissible to use (2) HDU11 holdowns at this location in lieu of the single HD19 holdown. Install per
manufacturer specifications. Both holdowns are to be connected into the same 6x8 post. The 1” anchor bolts
are to extend a minimum of 18” down into the concrete wall, to lap adequately with the vertical reinforcement.
- Refer to the attached sketch and supporting calculations.
The recommendations above are provided based upon our review of calculations and drawings generated from
information the client provided. A representative from Vector has not visited the construction site. No observation
was made of the structural integrity, materials used or quality of work of any portion of the structure.
We hope this meets your needs. If you have any further questions regarding this matter, please call this office at your
convenience.
Sincerely,
VECTOR STRUCTURAL ENGINEERING, LLC
_______________________________________
Wells L. Holmes, S.E.
Principal
WLH/rti
09/12/2023
09/12/2023
(2)
PLAN VIEW