Loading...
HomeMy WebLinkAboutREDLINED PLANS - 23-00435 - Precision Precast - New Commercial BldgAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314 Don Allen Don.Allen@rexburg.org 208-372-2174 Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : Precision Precast - New Commercial Bldg Address : RP05TSB0020040 Application Type : Document Filename : Drawings 7-7-23.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Pg 1 Free Text Cody Jones : Building Open 1 Architectural drawings needed for interior. Plans good for Footing, foundation and shell only. Pg 1 Free Text Alex Owens : Electrical Open 1 No electrical plans provided. Please provide electrical plans that include size of service and available fault current calculation. All electrical work must meet 2017 NEC requirements. Pg 10 Callout Stan Crittenden : Fire Open 10 International fire code section 503.1 requires that the fire access road reach with in 150 ft. of all portions of the building. # 23-00435 Madison County - Commercial Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 07.18.2023 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) Re v . 7/ 7 / 2 0 2 3 4: 0 3 : 4 7 P M CO V E R Au t h o r Pr e c i s i o n P r e c a s t A1 0 1 Precision Precast 60'x175' 1 COVER AcÑW_WUhf>US_Ñd_SbgÑdfcM>VWV•ÑC_WSgWÑ dfcM>VWÑW_WUhf>US_Ñd_SbgÑh=ShÑ>bU_iVWÑg>oW c;ÑgWfM>UWÑSbVÑSMS>_ST_WÑ;Si_hÑUiffWbhÑ US_Ui_Sh>cb•Ñ2__ÑW_WUhf>US_Ñlcf@ÑCighÑ CWWhѽޤÁÑA64ÑfWei>fWCWbhg• 2fU=>hWUhifS_ÑVfSl>b< gÑbWWVWVÑ;cfÑ>bhWf>cf• C_SbgÑ< ccVÑ;cfÑ7 cch>b< 8Ñ;cibVSh>cbÑSbVÑg=W__Ñcb_n • Re v . 7/ 7 / 2 0 2 3 4: 0 3 : 4 8 P M 3d V i e w s Au t h o r Pr e c i s i o n P r e c a s t A1 0 3 1 Alt 3D #2 2 Alt 3D UP Re f . 18' x 18' OHD 60 ' - 0 " 8' - 0" 30' - 0" Office Office Office Break Room Mech Room Conference Room Shop Space 11' - 9" 11 ' - 2 " Re v . 7/ 7 / 2 0 2 3 4: 0 3 : 4 8 P M FL O O R P L A N Au t h o r Pr e c i s i o n P r e c a s t A1 0 2 1/8" = 1'-0"1 100 100 0' -0" 102 2' -0" 128 28' -0" 1 2 3 4 5 6 110 10' -0" 134.33 34' -4 1/8" 7 120 20' -0" 8 Pearl Gray 100 0' -0" 102 2' -0" 128 28' -0" 123456 110 10' -0" 134.33 34' -4 1/8" 7 120 20' -0" 102.1 2' -2" 8 Brite Red Regal White Re v . 7/ 7 / 2 0 2 3 4: 0 3 : 4 9 P M EL E V A T I O N Au t h o r Pr e c i s i o n P r e c a s t A1 0 4 1/16" = 1'-0"2 West 1/16" = 1'-0"1 East 100 0' -0" 102 2' -0" 128 28' -0" 110 10' -0" 134.33 34' -4 1/8" 120 20' -0" 102.1 2' -2" 9 100 0' -0" 102 2' -0" 128 28' -0" 110 10' -0" 134.33 34' -4 1/8" 120 20' -0" 102.1 2' -2" 9 Re v . 7/ 7 / 2 0 2 3 4: 0 3 : 5 0 P M EL E V A T I O N Au t h o r Pr e c i s i o n P r e c a s t A1 0 5 3/32" = 1'-0"1 North 3/32" = 1'-0"2 South UP Re f . 1 2 3 4 5 6 7 60' - 0" 24 ' - 4 " 18' x 18' OHD 16' x 18' OHD 15 0 ' - 0 " 25 ' - 0 " 25 ' - 0 " 25 ' - 0 " 25 ' - 0 " 25 ' - 0 " 25 ' - 0 " 60' - 0" 10 ' - 0 " 9' - 8 " 4' - 0 " 4' - 0"7' - 6" 7' - 6 " 16' - 9" 19 ' - 1 " 11 ' - 2 " 30' - 0" 11 ' - 8 " 10 ' - 0 " 8 9 10 ' - 0 " 4' - 0 " 6' - 0 " 3' - 0 " 3' - 0 " Septic Tank Well Location 25 ' - 0 " Break Room 8' - 0" 5' - 0 " 7' - 0 " 15 ' - 0 " 12' - 2" 4' - 6" Mech. 4' - 7 " 10' - 0" 3' - 0 " UP Re f . 1 2 3 4 5 6 7 8 9 60' - 0" 24 ' - 4 " 18' x 18' OHD 16' x 18' OHD 15 0 ' - 0 " 25 ' - 0 " 25 ' - 0 " 25 ' - 0 " 25 ' - 0 " 25 ' - 0 " 25 ' - 0 " 60' - 0" 10 ' - 0 " 9' - 8 " 4' - 0 " 11' - 6" 4' - 6" 11' - 9" 4' - 0"7' - 6 " 14 ' - 1 1 " 11 ' - 8 " 19 ' - 1 " 11 ' - 2 " 30' - 0" 11 ' - 8 " 10 ' - 0 " 60 ' - 0 " 30 ' - 0 " 7' - 6 " 14 ' - 1 1 " 7' - 0 " 11 ' - 2 " 4' - 7 " 7' - 6" 9' - 0" 4' - 1 1 " 20' - 8" 8' - 0" Stairways will meet requirements of section 1011 and 1019. Handrails and guardrails will meet requirements of section 1014 and 1015. Concealed spaces need to have fire stopping ad blocking. Fire wall will have all penetrations fire sealed. Cross slope of sidewalk and landings not to exceed 2% 2hr Fire Seperation Wall Between Office and Shop -Special Inspections by Connect Engineering -Exit Lighting and Signs will Comply with Section 1008 and 1013 -Doors will meet Section 1010 Business Space B Occupancy 304.1 Business Group Type V-B Construction 24 person Occupancy (30 x 60 x 2)/150=24 Table 1004.5 9,000 S.F. allowed area Table 506.2 (NS, Type V-B) 1 hr fire rated door Storage Space F-2 Occupancy 306.3 Low-Hazard Factory Industrial Type II-B Construction 21 person Occupancy 10,300/500=21 Table 1004.5 23,000 S.F. allowed area Table 506.2 (NS, Type II B) No fire Sprinklers required under 12,000 s.f. 903.2.4 52' - 0" Small Concrete Batch Plant Gravel Storage DN Empty Space For Future Second Floor Ref. _ DW Dr y e r Wa s h e r Re f . 1 2 3 4 5 6 7 8 27 ' - 0 " 9 75' - 0"60' - 0"158' - 10 5/16" 51' - 6" 5 7 ' - 3 " Septic Tank Well Location 27'-3" 50'-0" 175'-0 " 50'-0" 150'-0" 280'-0" 200'-0" 10'-0" 7'-0"PROPOSED WELL LOCATION 100'-0" PROPOSED SEPTIC LOCATION International fire code section 5 03 .1 requires that the fire access road reach with in 15 0 ft. of all portions of the building . Acreage MCNABB CARLEESecondary Owner: Site Address: GIS Acres: Value Total Value: 79,876 Category Mailing Address: REXBURG Primary Owner: 584 E 7800 S 2 RP05TSB0020040 MCNABB MARK GIS Square Feet: 1.834 83440 $25,000 ID Parcel Number: Acreage: Description $25,000Total Value: Legal Description: TEXAS SIDING BUSINESS PARK LOT 4 BLOCK 2 05N39E SEC. 23 Deed Number: TCA Assessment values are approximate, to get accurate values contact the Madison County Assessor's Office (208) 359-6243. Tax amounts are approximate values, to get accurate values contact Madison County Treasurer's Office (208) 359-6264. Year Inspected:2022 Last Year's Taxes: Current Year's Taxes: $251.50 13 Rural Commercial Tract 2.000 $25,0004000 455404 451989 449175 448796 Report generated: 5/30/2023 3:31:07 PMMadison County Parcel Report This map is a user generated static output from an Internet mapping site and is for reference only. Data layers that appear on this map may or may not be accurate, current, or otherwise reliable.