LIFE SAFETY PLANS - 23-00435 - Precision Precast - New Commercial Bldg
PR E L I M I N A R Y NO T FO R CO N S T R U C T I O N ID DA T E DE S C R I P T I O N STRUCTURAL MECHANICAL / PLUMBING ELECTRICAL G-101 CIVIL 30 5 1s t ST R E E T , ID A H O FA L L S ,ID 83 4 0 1 PH : 20 8 . 7 5 7 . 7 5 0 0 23085 PR E C I S I O N PR E - C A S T En t e r ad d r e s s he r e <D e f a u l t > Or i g i n a l do c u m e n t is on fi l e wi t h th e da t e an d ar c h i t e c t si g n a t u r e Or i g i n a l do c u m e n t s si g n e d by : 9/ 1 2 / 2 0 2 3 Da t e or i g i n a l do c u m e n t s si g n e d : TH E S E PL A N S , DR A W I N G S , AN D DE S I G N S AR E TH E EX C L U S I V E PR O P E R T Y OF RE S I N AR C H I T E C T U R E , LL C AN D SH A L L NO T BE RE P R O D U C E D IN AN Y FO R M WI T H O U T WR I T T E N CO N S E N T . AL L RI G H T S RE S E R V E D © 20 2 3 RE S I N AR C H I T E C T U R E , LL C . TH E S E PL A N S , DR A W I N G S , AN D DE S I G N S AR E TH E EX C L U S I V E PR O P E R T Y OF RE S I N AR C H I T E C T U R E , LL C AN D SH A L L NO T BE RE P R O D U C E D IN AN Y FO R M WI T H O U T WR I T T E N CO N S E N T . AL L RI G H T S RE S E R V E D © 20 2 3 RE S I N AR C H I T E C T U R E , LL C . FIRST FLOOR LIFE SAFETY PR E L I M I N A R Y FO R RE V I E W NO T FO R CO N S T R U C T I O N MECH. RM 102 46 SF 300 1 4' FE os 45 SPACE NAME / FUNCTIONAL USE ROOM NUMBER AREA OF ROOM / SPACE OCCUPANT LOAD FACTOR CALCULATED OCCUPANCY TRANSITION POINT FOR COMMON PATH OF EGRESS or TRAVEL DISTANCE EGRESS PATH PORTABLE FIRE EXTINGUISHER AND CABINET 45 MINUTE FIRE RATED DOOR ASSEMBLY 60 MIN. FIRE BARRIER WALL ASSEMBLY 60 MIN. FIRE BARRIER CEILING/FLOOR ASSEMBLY EXIT SIGN OR DIRECTIONAL EXIT SIGN PER PLANS LIFE SAFETY PLAN LEGEND ZONE TAG SWITCH W/ OCCUPANCY SENSOR MINIMUM CLEAR SPACE/ADA ACCESSIBLILITY CLEARANCE LIFE SAFETY GENERAL NOTES A.SEE "G" SERIES SHEETS FOR ACCESSIBILITY COMPLIANCE DETAILS PERTAINING TO DOOR SWING CLEARANCES, DRINKING FOUNTAIN AND SINK CLEAR SPACE REQUIREMENTS, ACCESSIBLE SIGNAGE, FLOOR TRANSITION DETAILS, ACCESSIBLE MOUNTING HEIGHTS, TOILET, SHOWER AND TUB REQUIREMENTS. B.FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING. (IFC 7032.2.1, IBC 703.6) LOCATED IN ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING OR ATTIC SPACES; REPEATED AT INTERVALS NOT EXCEEDING 30 FETT MEASURED HORIZONTALLY ALLONG THE WALL OR PARTITION; AND ICLUDE LETTERING NOT LESS THAN 0.5 INCH IN HEIGHT STATING "FIRE WALL, FIRE BARRIER AND/OR SMOKE BARRIER-PROTECT ALL OPENINGS" C.BUILDING WILL BE REQUIRED TO MEET APPROPRIATE EMERGENCY RESPONDER RADIO COVERAGE AS OUTLINED IN IFC 1103.2. TESTING SHALL BE REQUIRED TO DETERMINE THE LEVEL OF RADIO COVERAGE. BUILDINGS THAT DO NOT MEET THE MINIMUM REQUIREMENTS FOR EMERGENCY RESPONDER RADIO COVERAGE WILL BE REQUIRED TO INSTALL AN APPROVED RADIO AMPLIFIER SYSTEM. EMERGENCY EYE WASH STATION 1 2 3 4 5 6 7UP 1 2 3 4 5 6 7 UP 11 22 33 44 55 66 77 88 9 9 81' 81' 4'-0" 4' - 0 " Area 2 1,800 SF 300 6 Area 1 11,733 SF 300 40 Code Analysis Summary Building Codes:2018 International Building Code 2018 International Mechanical Code Authority Having Jurisdiction:2018 International Energy Conservation Code Madison County 2018 International Plumbing Code 2017 National Electrical Code (NEC) Property Address and Parcel Number add physical address add parcel number Building Occupancy Classification and Use Designation Use (Chapter 3)Factory Group F-2 F-2 Business Group B B Check Chapter 4 for applicability and insert here if applicable Types of Construction (Chapter 6)V-B No Sprinkler System General Building Heights and Areas Proposed Actual Allowed by IBC Allowable Building Height in Feet Above Grade Plane (Table 504.3): F-2/B 34'-4"40 Allowable Number of Stories Above Grade Plane (Table 504.4): F-2/B 2 2 Allowable Area Factor (Table 506.2): F-2 13,657 13,000 Allowable Increase for Frontage (506.3)22,660 Allowable Area Factor (Table 506.2): B 1,838 9,000 Allowable Increase for Frontage (506.3)15,688 Required Separation of Occupancies (Hours) (Table 508.4)Proposed Required Mixed Use Occupancies B / F-2 No Sprinkler System 1 1 Fire-Resistance Rating Requirements for Building Elements (Hours) (Table 601) Construction Type V-B Primary Structural Frame:0 Hour Bearing Walls, Exterior:0 Hour Bearing Walls, Interior:0 Hour Nonbearing Walls:0 Hour Floor Construction and associated secondary structural members:0 Hour Roof Construction and associated secondary structural members:0 Hour Fire-Resistance Rating Req. for Ext. Walls Based on Fire Separation Distance (Table 602) Exterior Walls:X >/= 30 0 Hour Fire-Resistance Rated Construction Fire Walls (Section 706)None Required Fire Barriers (Section 707, Table 508.4)B / F-2 1h Fire Partitions (Section 708, 420.2, 1018.1)None Required None Required Smoke Barriers (Section 709)Smoke Barriers are required because partitions are 1 hr rated Shaft Enclosures (Section 713) Shaft enclosures constructed as Fire Barriers to match other required barriers 1h Opening Protectives (Section 716) Protectives for Fire Barriers 1h Fire Protection Systems Automatic Sprinkler Systems:none required Portable Fire Extinguishers(906):75' Max Every 75' Fire Alarm and Detection System (907.2):none required Smoke Alarms (907.2)none required Occupant Load (Table 1004.1.1)Use Area/Occ.Area Total Occ. Use 1 “F-2”Factory-2 1st Floor Warehouse 500 13,657 28 Total “Warehouse” Occupancy:28 Use 2 “B”Offices 1st Floor Business 150 1,838 13 2nd Floor Business 150 1,838 13 Total “Business” Occupancy:26 Egress Capacity Required Provided Stairways (.3/Story per occupant)Section 1005.3.1 36" Minimum 1*48” Other Egress (.2”/occupant):Section 1005.3.2 32" Minimum 1 @ 36" Number of Exits Required 1 1 Exit Access Travel Distance (Table 1017.2)Factory F-2 300' Max.80' Exit Access Travel Distance (Table 1006.3.3.(2))Business B 75' Max.74' Minimum Number of Required Plumbing Fixtures (Table 2902.1) Factory Group F-2 1 per #Required Provided W.C.'s 100 0.28 Lavatories 100 0.28 Drinking Fountains 400 0.07 Service Sink Yes Business Group B 1 per #Required Provided W.C.'s 25 1.04 Lavatories 40 0.65 Drinking Fountains 100 0.26 Service Sink Yes Combined 1 per #Required Provided W.C.'s 1.32 3 Lavatories 0.93 3 Drinking Fountains 0.33 0 Service Sink 1.00 1 UP UP 30' - 6" 10 ' - 6" 21 ' - 7" 15 ' - 5 1/ 2 " 12 ' - 5 1/ 2 " 30 ' - 0" 30 ' - 0" 60 ' - 0" 17' - 5"13' - 1" 15 ' - 9" 11 ' - 6" 4' - 10 " 8' - 5 1/ 2 " 6' - 10 1/ 2 " 12 ' - 7" 7' - 6"4' - 10" 0' - 8" 0' - 6" 8' - 0" 9' - 3 1/2" 8' - 0"14' - 6"8' - 0" 10 ' - 1" 19' - 8" 4' - 7" 49' 5'-0" MIN 60 60 60 60 60 Code Analysis SummaryBuilding Codes:2018 International Building Code2018 International Mechanical CodeAuthority Having Jurisdiction:2018 International Energy Conservation CodeMadison County 2018 International Plumbing Code2017 National Electrical Code (NEC)Property Address and Parcel Numberadd physical addressadd parcel numberBuilding Occupancy Classification and Use DesignationUse (Chapter 3)Factory Group F-2 F-2Business Group B BCheck Chapter 4 for applicability and insert here if applicableTypes of Construction (Chapter 6)V-B No Sprinkler SystemGeneral Building Heights and Areas Proposed Actual Allowed by IBCAllowable Building Height in Feet Above Grade Plane (Table 504.3): F-2/B 34'-4"40Allowable Number of Stories Above Grade Plane (Table 504.4): F-2/B 2 2Allowable Area Factor (Table 506.2): F-2 13,657 13,000Allowable Increase for Frontage (506.3)22,660Allowable Area Factor (Table 506.2): B 1,838 9,000Allowable Increase for Frontage (506.3)15,688Required Separation of Occupancies (Hours) (Table 508.4)Proposed RequiredMixed Use Occupancies B / F-2 No Sprinkler System 1 1Fire-Resistance Rating Requirements for Building Elements (Hours) (Table 601)Construction Type V-BPrimary Structural Frame:0 HourBearing Walls, Exterior:0 HourBearing Walls, Interior:0 HourNonbearing Walls:0 HourFloor Construction and associated secondary structural members:0 HourRoof Construction and associated secondary structural members:0 HourFire-Resistance Rating Req. for Ext. Walls Based on Fire Separation Distance (Table 602)Exterior Walls:X >/= 30 0 HourFire-Resistance Rated ConstructionFire Walls (Section 706)None Required Fire Barriers (Section 707, Table 508.4)B / F-2 1h Fire Partitions (Section 708, 420.2, 1018.1)None Required None Required Smoke Barriers (Section 709)Smoke Barriers are required because partitions are 1 hr rated Shaft Enclosures (Section 713) Shaft enclosures constructed as Fire Barriers to match other required barriers 1h Opening Protectives (Section 716) Protectives for Fire Barriers 1h Fire Protection Systems Automatic Sprinkler Systems:none required Portable Fire Extinguishers(906):75' Max Every 75' Fire Alarm and Detection System (907.2):none required Smoke Alarms (907.2)none required Occupant Load (Table 1004.1.1)Use Area/Occ.Area Total Occ. Use 1 “F-2”Factory-2 1st Floor Warehouse 500 13,657 28 Total “Warehouse” Occupancy:28 Use 2 “B”Offices 1st Floor Business 150 1,838 13 2nd Floor Business 150 1,838 13 Total “Business” Occupancy:26 Egress Capacity Required Provided Stairways (.3/Story per occupant)Section 1005.3.1 36" Minimum 1*48” Other Egress (.2”/occupant):Section 1005.3.2 32" Minimum 1 @ 36" Number of Exits Required 1 1 Exit Access Travel Distance (Table 1017.2)Factory F-2 300' Max.80' Exit Access Travel Distance (Table 1006.3.3.(2))Business B 75' Max.74' Minimum Number of Required Plumbing Fixtures (Table 2902.1) Factory Group F-2 1 per #Required Provided W.C.'s 100 0.28 Lavatories 100 0.28 Drinking Fountains 400 0.07 Service Sink Yes Business Group B 1 per #Required Provided W.C.'s 25 1.04 Lavatories 40 0.65 Drinking Fountains 100 0.26 Service Sink Yes Combined 1 per #Required Provided W.C.'s 1.32 3 Lavatories 0.93 3 Drinking Fountains 0.33 0 Service Sink 1.00 1 SCALE: 1/16" = 1'-0"1 WAREHOUSE LIFE SAFETY PLAN SCALE: 1/8" = 1'-0"2 FIRST FLOOR LIFE SAFETY PLAN 9.12.23 ID DA T E DE S C R I P T I O N STRUCTURAL MECHANICAL / PLUMBING ELECTRICAL G-102 CIVIL 30 5 1s t ST R E E T , ID A H O FA L L S ,ID 83 4 0 1 PH : 20 8 . 7 5 7 . 7 5 0 0 23085 PR E C I S I O N PR E - C A S T En t e r ad d r e s s he r e <D e f a u l t > Or i g i n a l do c u m e n t is on fi l e wi t h th e da t e an d ar c h i t e c t si g n a t u r e Or i g i n a l do c u m e n t s si g n e d by : 9/ 1 2 / 2 0 2 3 Da t e or i g i n a l do c u m e n t s si g n e d : TH E S E PL A N S , DR A W I N G S , AN D DE S I G N S AR E TH E EX C L U S I V E PR O P E R T Y OF RE S I N AR C H I T E C T U R E , LL C AN D SH A L L NO T BE RE P R O D U C E D IN AN Y FO R M WI T H O U T WR I T T E N CO N S E N T . AL L RI G H T S RE S E R V E D © 20 2 3 RE S I N AR C H I T E C T U R E , LL C . TH E S E PL A N S , DR A W I N G S , AN D DE S I G N S AR E TH E EX C L U S I V E PR O P E R T Y OF RE S I N AR C H I T E C T U R E , LL C AN D SH A L L NO T BE RE P R O D U C E D IN AN Y FO R M WI T H O U T WR I T T E N CO N S E N T . AL L RI G H T S RE S E R V E D © 20 2 3 RE S I N AR C H I T E C T U R E , LL C . SECOND FLOOR LIFE SAFETY PR E L I M I N A R Y FO R RE V I E W NO T FO R CO N S T R U C T I O N MECH. RM 102 46 SF 300 1 4' FE os 45 SPACE NAME / FUNCTIONAL USE ROOM NUMBER AREA OF ROOM / SPACE OCCUPANT LOAD FACTOR CALCULATED OCCUPANCY TRANSITION POINT FOR COMMON PATH OF EGRESS or TRAVEL DISTANCE EGRESS PATH PORTABLE FIRE EXTINGUISHER AND CABINET 45 MINUTE FIRE RATED DOOR ASSEMBLY 60 MIN. FIRE BARRIER WALL ASSEMBLY 60 MIN. FIRE BARRIER CEILING/FLOOR ASSEMBLY EXIT SIGN OR DIRECTIONAL EXIT SIGN PER PLANS LIFE SAFETY PLAN LEGEND ZONE TAG SWITCH W/ OCCUPANCY SENSOR MINIMUM CLEAR SPACE/ADA ACCESSIBLILITY CLEARANCE LIFE SAFETY GENERAL NOTES A.SEE "G" SERIES SHEETS FOR ACCESSIBILITY COMPLIANCE DETAILS PERTAINING TO DOOR SWING CLEARANCES, DRINKING FOUNTAIN AND SINK CLEAR SPACE REQUIREMENTS, ACCESSIBLE SIGNAGE, FLOOR TRANSITION DETAILS, ACCESSIBLE MOUNTING HEIGHTS, TOILET, SHOWER AND TUB REQUIREMENTS. B.FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING. (IFC 7032.2.1, IBC 703.6) LOCATED IN ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING OR ATTIC SPACES; REPEATED AT INTERVALS NOT EXCEEDING 30 FETT MEASURED HORIZONTALLY ALLONG THE WALL OR PARTITION; AND ICLUDE LETTERING NOT LESS THAN 0.5 INCH IN HEIGHT STATING "FIRE WALL, FIRE BARRIER AND/OR SMOKE BARRIER-PROTECT ALL OPENINGS" C.BUILDING WILL BE REQUIRED TO MEET APPROPRIATE EMERGENCY RESPONDER RADIO COVERAGE AS OUTLINED IN IFC 1103.2. TESTING SHALL BE REQUIRED TO DETERMINE THE LEVEL OF RADIO COVERAGE. BUILDINGS THAT DO NOT MEET THE MINIMUM REQUIREMENTS FOR EMERGENCY RESPONDER RADIO COVERAGE WILL BE REQUIRED TO INSTALL AN APPROVED RADIO AMPLIFIER SYSTEM. EMERGENCY EYE WASH STATION OCCUPANCY & OCCUPANT LOAD SCHEDULE STORY 100 Doors and Windows, ZONE NUMBER 1 2 ZONE NAME Area Area MEASURED AREA 11,733.33 1,800.00 13,533.33 ft² SPACE FUNCTION OCCUPANT LOAD 300 300 OCCUPANTS 1 1 2 Code Analysis Summary Building Codes:2018 International Building Code 2018 International Mechanical Code Authority Having Jurisdiction:2018 International Energy Conservation Code Madison County 2018 International Plumbing Code 2017 National Electrical Code (NEC) Property Address and Parcel Number add physical address add parcel number Building Occupancy Classification and Use Designation Use (Chapter 3)Factory Group F-2 F-2 Business Group B B Check Chapter 4 for applicability and insert here if applicable Types of Construction (Chapter 6)V-B No Sprinkler System General Building Heights and Areas Proposed Actual Allowed by IBC Allowable Building Height in Feet Above Grade Plane (Table 504.3): F-2/B 34'-4"40 Allowable Number of Stories Above Grade Plane (Table 504.4): F-2/B 2 2 Allowable Area Factor (Table 506.2): F-2 13,657 13,000 Allowable Increase for Frontage (506.3)22,660 Allowable Area Factor (Table 506.2): B 1,838 9,000 Allowable Increase for Frontage (506.3)15,688 Required Separation of Occupancies (Hours) (Table 508.4)Proposed Required Mixed Use Occupancies B / F-2 No Sprinkler System 1 1 Fire-Resistance Rating Requirements for Building Elements (Hours) (Table 601) Construction Type V-B Primary Structural Frame:0 Hour Bearing Walls, Exterior:0 Hour Bearing Walls, Interior:0 Hour Nonbearing Walls:0 Hour Floor Construction and associated secondary structural members:0 Hour Roof Construction and associated secondary structural members:0 Hour Fire-Resistance Rating Req. for Ext. Walls Based on Fire Separation Distance (Table 602) Exterior Walls:X >/= 30 0 Hour Fire-Resistance Rated Construction Fire Walls (Section 706)None Required Fire Barriers (Section 707, Table 508.4)B / F-2 1h Fire Partitions (Section 708, 420.2, 1018.1)None Required None Required Smoke Barriers (Section 709)Smoke Barriers are required because partitions are 1 hr rated Shaft Enclosures (Section 713) Shaft enclosures constructed as Fire Barriers to match other required barriers 1h Opening Protectives (Section 716) Protectives for Fire Barriers 1h Fire Protection Systems Automatic Sprinkler Systems:none required Portable Fire Extinguishers(906):75' Max Every 75' Fire Alarm and Detection System (907.2):none required Smoke Alarms (907.2)none required Occupant Load (Table 1004.1.1)Use Area/Occ.Area Total Occ. Use 1 “F-2”Factory-2 1st Floor Warehouse 500 13,657 28 Total “Warehouse” Occupancy:28 Use 2 “B”Offices 1st Floor Business 150 1,838 13 2nd Floor Business 150 1,838 13 Total “Business” Occupancy:26 Egress Capacity Required Provided Stairways (.3/Story per occupant)Section 1005.3.1 36" Minimum 1*48” Other Egress (.2”/occupant):Section 1005.3.2 32" Minimum 1 @ 36" Number of Exits Required 1 1 Exit Access Travel Distance (Table 1017.2)Factory F-2 300' Max.80' Exit Access Travel Distance (Table 1006.3.3.(2))Business B 75' Max.74' Minimum Number of Required Plumbing Fixtures (Table 2902.1) Factory Group F-2 1 per #Required Provided W.C.'s 100 0.28 Lavatories 100 0.28 Drinking Fountains 400 0.07 Service Sink Yes Business Group B 1 per #Required Provided W.C.'s 25 1.04 Lavatories 40 0.65 Drinking Fountains 100 0.26 Service Sink Yes Combined 1 per #Required Provided W.C.'s 1.32 3 Lavatories 0.93 3 Drinking Fountains 0.33 0 Service Sink 1.00 1 DN DN Future Lounge Future Office 3 Future Office 4 Future Kitchen Future Bathroom 30' - 6" 13' - 2" 16 ' - 3" 30 ' - 1" 13 ' - 8" 60 ' - 0" 26 ' - 10 " 6' - 0" 7' - 10 " 19 ' - 4" 30' - 0" Future Storage 12' - 4" 13 ' - 1" 12 ' - 9" 11 ' - 9" 15 ' - 9" 4' - 0" 4' - 0" 6' - 2" 12 ' - 1" 8' - 0" 71' 60 SCALE: 1/8" = 1'-0"1 SECOND FLOOR LIFE SAFETY PLAN 9.12.23 PR E L I M I N A R Y NO T FO R CO N S T R U C T I O N ID DA T E DE S C R I P T I O N STRUCTURAL MECHANICAL / PLUMBING ELECTRICAL CIVIL G-401 30 5 1s t ST R E E T , ID A H O FA L L S ,ID 83 4 0 1 PH : 20 8 . 7 5 7 . 7 5 0 0 23085 PR E C I S I O N PR E - C A S T En t e r ad d r e s s he r e <D e f a u l t > Or i g i n a l do c u m e n t is on fi l e wi t h th e da t e an d ar c h i t e c t si g n a t u r e Or i g i n a l do c u m e n t s si g n e d by : 9/ 1 2 / 2 0 2 3 Da t e or i g i n a l do c u m e n t s si g n e d : TH E S E PL A N S , DR A W I N G S , AN D DE S I G N S AR E TH E EX C L U S I V E PR O P E R T Y OF RE S I N AR C H I T E C T U R E , LL C AN D SH A L L NO T BE RE P R O D U C E D IN AN Y FO R M WI T H O U T WR I T T E N CO N S E N T . AL L RI G H T S RE S E R V E D © 20 2 3 RE S I N AR C H I T E C T U R E , LL C . TH E S E PL A N S , DR A W I N G S , AN D DE S I G N S AR E TH E EX C L U S I V E PR O P E R T Y OF RE S I N AR C H I T E C T U R E , LL C AN D SH A L L NO T BE RE P R O D U C E D IN AN Y FO R M WI T H O U T WR I T T E N CO N S E N T . AL L RI G H T S RE S E R V E D © 20 2 3 RE S I N AR C H I T E C T U R E , LL C . TYPICAL DETAILS/ ACCESSIBILITY COMPLIANCE PR E L I M I N A R Y FO R RE V I E W NO T FO R CO N S T R U C T I O N TREAD1'-11" (TREAD+12") 11"MIN TYP. TREAD 1'-0" MIN. 2' - 9 " 34 " - 3 8 " 7" MA X . 1 1/ 2 " MI N . RETURN ENDS INTO WALL WITH RADIUS. TYPICAL 1/4" RADIUS, TYPICAL HANDRAIL BRACKETS SPACED AT 5'-0" O.C. MAX, 12" MAX. FROM EACH END HANDRAIL; REFER TO PLAN AND SECTIONS FOR TYPE AND LENGTH RETURN HANDRAIL TO WALL WITH 1/4" MAX GAP. RETURN HANDRAIL TO WALL WITH 1/4" MAX GAP. RETURN HANDRAIL TO WALL WITH 1/4" MAX GAP. DOORSTOP WHERE OCCURS WOOD BLOCKING - OR BRIDGING, 2 x 10 CONTINUOUS AT CASEWORK SEE SPECIFICATIONS FRAMING AS SPECIFIED GYP. BD. PER PLANSGYP. BD. PER PLANS NOTE: 1. PROVIDE CONTINUOUS BLOCKING AT ALL UPPER CABINETS. SEE PLANS AND ELEVATIONS FOR CABINET LOCATIONS. ALSO PROVIDE BLOCKING AT ALL GRAB BARS, WALL MOUNTED SINKS, AND ALL OTHER WALL MOUNTED EQUIPMENT. 2. PROVIDE FIRE RATED BLOCKING AT ALL RATED CONSTRUCTION LOCATIONS 1 1/2" 2X10 BLOCKING FLANGE FASTENERS PER MANUFACTURERS INSTALLATION INSTRUCTIONS CONCEALED MOUNTING PLATE 1 1/2" DIAMETER GRAB BAR GYPSUM BOARD WALL FINISH WHERE OCCURS SEPARATE LOCATIONS OF ELECTRICAL PENETRATIONS BY ONE STUD MIN. WOOD STUD FRAMING ACOUSTICAL BATT INSULATION (1) LAYER GYPSUM BOARD - EACH SIDE ACOUSTICAL SEALANT - TYP. ITEM BY DIV. 26 - ELECTRICAL BOX. TYP. WALL TYPE AS NOTED ON PLANS F.E. AND SEMI-RECESSED CABINET - SIZE OPENING PER MANUFACTURER'S INSTRUCTIONS SEALANT - EACH SIDE G.B. BOX BEHIND CABINET (WHERE REQUIRED FOR 1 HR F.R.R. ASSEMBLY BLOCKING AS REQUIRED FOR INSTALLATION WOOD / METAL FRAMING PER PLANS PROTECTED RAILS MAY BE OMITTED WHEN FIXTURE IS LOCATED COMPLETELY IN ALCOVE. SIMILAR DIMENSIONAL CLEARNACES APPLY. SEE FLOOR PLAN. 6" MA X 3' - 0 " 1'-6" MIN 5" MAX 15" MIN 39 " OF SP O U T 27 " MI N 16" MIN TO OF FOUNTAIN 16" MIN TO OF FOUNTAIN 36 " MA X OF SP O U T SPOUT PUSH BUTTON STANDARD HEIGHT FOUNTAIN ACCESSIBLE FOUNTAIN 34 " MA X 27 " MI N 8" MIN 9" MI N 11" MIN KNEE CLEARANCE 6 1/ 2 " MA X 6" MAX TOE CLEARANCE 25" MAX KNEE & TOE CLEARANCE KNEE SPACE CLEAR 2009/2017 1/2" NOTES: SEE ENLARGED FLOOR PLANS FOR ADDITIONAL CLEARANCES. 17 " MA X 44 " MA X 13 MIN 15" MIN. 40 " MA X 2' - 1 0 " 2' - 3 " MI N 40 " MA X 11"11" FAUCET OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST INSUL. DRAIN & HOT WATER SUPPLY PIPES FRAMED GLASS MIRROR PAPER TOWEL DISPENSERLIQUID SOAP DISPENSER TYP. LIQUID SOAP & PAPER TOWEL DISP. FLOOR LEVEL MIRROR SANITARY NAPKIN DISPENSER PAPER TOWEL DISPENSER TOILET SEAT COVER DISPENSER SOAP DISPENSER (VERT. & HORIZ.) INFANT CHANGING TABLE 24 " MI N40 " MA X 24 " MI N 2' - 9 1/ 2 " OPERABLE PART OF ACCESSORY SHALL BE WITHIN AREA SHOWN SHADED U.O.N FLOOR LEVEL FLOOR LEVEL DISPENCER OPT 2 18 " MI N . 39 " - 4 1 " 42" MIN. 12" MAX. 16"-18" 17 " - 1 9 " 33 " - 3 6 " 39"-41" 54" MIN. 33 " - 3 6 " 36" MIN. 6" MAX 42" MIN 36" GRAB BAR 42" GRAB BAR 18" GRAB BAR SEE TYP. TOILET PAPER DISPENSERS DETAIL NOTE: 1)TYP. AT ALL ADA ACCESSIBLE TOLIETS 2)PROVIDE AND INSTALL SOLID BACKING AT ALL WALL MOUNTED FIXTURES 3)PROVIDE FLUSH CONTROL ON THE OPEN SIDE OF WATER CLOSET ANSI 2017 24" MIN 42" MAX 24" MIN 36" MAX 18 " MI N 48 ' MI N 12" MIN1 1/2" MIN NOTE: 1)THE AREAS INDICATED ARE TO BE THE LOCATIONS OF THE OUTLET OF THE DISPENSERS 2)DISPENSER SHALL NOT BE OF A TYPE THAT CONTROL DELIVERY, OR DO NOT ALLOW CONTINUOUS PAPER FLOW 3) PROVIDE AND INSTALL SOLID BACKING AT ALL WALL MOUNTED FIXTURES ANSI 2009/2017 SCALE: 1" = 1'-0"A4 STAIR AND HANDRAIL DETAIL SCALE: 1 1/2"= 1'-0"B1 SOLID BLOCKING DETAIL SCALE: 3" = 1'-0"B2 GRAB BAR DETAIL SCALE: 3" = 1'-0"A1 STAGGERED OUTLET DETAIL SCALE: 1 1/2"= 1'-0"A2 RECESSED CABINET SCALE: 3/4" = 1'-0"B3 DRINKING FOUNTAIN SCALE: 3/4" = 1'-0"A3 ACCESSIBLE KNEE CLEARANCE SCALE: 1/2" = 1'-0"B4 1/2" GENERAL DETAILS SCALE: 1/2" = 1'-0"C4 TYP. ADA BATHROOM @ LAV SCALE: 1/2" = 1'-0"C3 TYP. ADA BATHROOM FIXTURES SCALE: 1/2" = 1'-0"C1 TYP. ADA TOILET SCALE: 1/2" = 1'-0"C2 TYP. TOILET PAPER DISPENSER 9.12.23 PR E L I M I N A R Y NO T FO R CO N S T R U C T I O N ID DA T E DE S C R I P T I O N STRUCTURAL MECHANICAL / PLUMBING ELECTRICAL CIVIL G-402 30 5 1s t ST R E E T , ID A H O FA L L S ,ID 83 4 0 1 PH : 20 8 . 7 5 7 . 7 5 0 0 23085 PR E C I S I O N PR E - C A S T En t e r ad d r e s s he r e <D e f a u l t > Or i g i n a l do c u m e n t is on fi l e wi t h th e da t e an d ar c h i t e c t si g n a t u r e Or i g i n a l do c u m e n t s si g n e d by : 9/ 1 2 / 2 0 2 3 Da t e or i g i n a l do c u m e n t s si g n e d : TH E S E PL A N S , DR A W I N G S , AN D DE S I G N S AR E TH E EX C L U S I V E PR O P E R T Y OF RE S I N AR C H I T E C T U R E , LL C AN D SH A L L NO T BE RE P R O D U C E D IN AN Y FO R M WI T H O U T WR I T T E N CO N S E N T . AL L RI G H T S RE S E R V E D © 20 2 3 RE S I N AR C H I T E C T U R E , LL C . TH E S E PL A N S , DR A W I N G S , AN D DE S I G N S AR E TH E EX C L U S I V E PR O P E R T Y OF RE S I N AR C H I T E C T U R E , LL C AN D SH A L L NO T BE RE P R O D U C E D IN AN Y FO R M WI T H O U T WR I T T E N CO N S E N T . AL L RI G H T S RE S E R V E D © 20 2 3 RE S I N AR C H I T E C T U R E , LL C . ACCESSIBILITY COMPLIANCE PR E L I M I N A R Y FO R RE V I E W NO T FO R CO N S T R U C T I O N 4' - 6 " 4' - 0 " 6' - 6 " 2' - 3 " MA X 5' - 9 " FEC OR FHV CABINET FE ELECTRICAL PANEL BOARD (NON- PROTRUDING) ELECTRICAL PANEL BOARD (PROTRUDIN G) FLOOR LEVEL EXIT EXIT 3" 9" OR GR E A T E R AL I G N W/ TO P OF AD J A C E N T FR A M E MO U N T ON ST R I K E SI D E WH E N DI M . AB O V E DO O R HE A D IS <1 2 " 1' - 0 " EQ EQ WALL MOUNTED EXIT SIGN AT EXIT DOOR LO C A T E 3" AB O V E DO O R FR A M E WH E N DI M . AB O V E DO O R HE A D IS 12 " OR GR E A T E R FLOOR LEVEL 1' - 6 " 4' - 0 " MA X @ T. 0 . FI X T U R E 1'-3" MIN. @ B.O. FIXTURE TY P . RE A C H RA N G E 3' - 9 " T-STAT OR FIRE ALARM CARD READER, KEYPAD, CARD READER / KEYPAD COMBO, LOCAL ALARM, OR ARMING STATION PUSH PLATE MANUAL FIRE ALARM PULL STATION LIGHT SWITCH DUPLEX OUTLET WALL MTD. TELEPH ONE JACK FLOOR LEVEL CARPET PILE HEIGHT GENERAL 1:2 BEVEL (a) 1:2 BEVEL (b) 1/2" MAX 1/4" MAX1/4" MAX 1/2" MAX 1/4" MAX 1/4"-1/2" MAX NOTES: 1. SIDE CLEARANCE IS ALSO REQUIRED IF THE PLANE OF THE DOOR IS RECESSED MORE THAN 8" FROM WALL PLANE, OR MORE THAN 8" FROM ANY OBSTRUCTION WITHIN 18" HORIZONTALLY OF THE LATCH SIDE. 60" MIN. CLEAR LEVEL FLOOR IN DIRECTION OF DOOR SWING 48" MIN. CLEAR LEVEL FLOOR ON SIDE OPPOSITE DOOR SWING 22 " HI N G E AP P R O A C H PU L L SI D E 12 " PU S H SI D E CL E A R A N C E 18 " PU L L SI D E CL E A R A N C E 36 " HI N G E AP P R O A C H PU L L SI D E A A NOTESNOTES: 1. DOORS ARE TO BE PROVIDED (NOT SHOWN FOR CLARITY) 2. INSTALL INSULATION ON EXPOSED PIPES UNDER SINK PER PLUMBING SPECS 3. RUN FLOORING AND BASE INTO WHEELCHAIR SPACE 4. NO SHARP OR ABRASIVE SURFACES UNDER SINKS & COUNTER SECTION 1 1/2"=1'-0" 30" CLR MIN 1'- 6 " 29 " CL R AT AP R O N 27 " CL R AT SI N K 34 " MA X PLYWOOD TOE KICK W/ BASE REMOVABLE BOTTOM SHELF; FILL ENTIRE VOID TOE KICK W/ BASE RECESS FOR BASE, TYP REMOVABLE SHELF (BRAILLE) (BRAILLE) TACTILE EXIT ROUTE TACTILE EXIT NOTE: 1. SIGN SHALL BE OF ENGRAVED LAMINATED ACRYLIC 2. CHARACTERS AND SPACING PER ICC A117.1 - 2009 703.7 A. B. #2 BRAILLE REPEAT ALL TEXT IN BRAILLE COMPLIANT W/ ICC A117.1 - 2009 703.4 2" 3" 4" TYP (BRAILLE) TACTILE EXIT ROUTE C. NOTE: 1. SIGN SHALL BE OF ENGRAVED LAMINATED ACRYLIC 2. CHARACTERS AND SPACING PER ICC A117.1 - 2009 703.7 4" 4" TYP 60 " MA X 48 " MI N SCALE: 1/2" = 1'-0"A3 TYP. WALL MOUNTED FIXTURES SCALE: 1/2" = 1'-0"A1 EXIT SIGN @ DOORWAY SCALE: 1/2" = 1'-0"B3 TYP. MOUNTING HEIGHTS SCALE: 3" = 1'-0"B2 VERTICAL LEVEL CHANGE SCALE: 1/2" = 1'-0"A2 DOOR CLEARANCES SCALE: 1/2" = 1'-0"C2 ACCB. CAB W/ REMOVABLE SHELF SCALE: 6" = 1'-0"B1 EXIT ROUTE SIGN SCALE: 6" = 1'-0"C1 EXIT STAIR ROUTE SIGN 9.12.23 ID DA T E DE S C R I P T I O N STRUCTURAL MECHANICAL / PLUMBING ELECTRICAL CIVIL G-403 30 5 1s t ST R E E T , ID A H O FA L L S ,ID 83 4 0 1 PH : 20 8 . 7 5 7 . 7 5 0 0 23085 PR E C I S I O N PR E - C A S T En t e r ad d r e s s he r e <D e f a u l t > Or i g i n a l do c u m e n t is on fi l e wi t h th e da t e an d ar c h i t e c t si g n a t u r e Or i g i n a l do c u m e n t s si g n e d by : 9/ 1 2 / 2 0 2 3 Da t e or i g i n a l do c u m e n t s si g n e d : TH E S E PL A N S , DR A W I N G S , AN D DE S I G N S AR E TH E EX C L U S I V E PR O P E R T Y OF RE S I N AR C H I T E C T U R E , LL C AN D SH A L L NO T BE RE P R O D U C E D IN AN Y FO R M WI T H O U T WR I T T E N CO N S E N T . AL L RI G H T S RE S E R V E D © 20 2 3 RE S I N AR C H I T E C T U R E , LL C . TH E S E PL A N S , DR A W I N G S , AN D DE S I G N S AR E TH E EX C L U S I V E PR O P E R T Y OF RE S I N AR C H I T E C T U R E , LL C AN D SH A L L NO T BE RE P R O D U C E D IN AN Y FO R M WI T H O U T WR I T T E N CO N S E N T . AL L RI G H T S RE S E R V E D © 20 2 3 RE S I N AR C H I T E C T U R E , LL C . ACCESSIBILITY COMPLIANCE PR E L I M I N A R Y FO R RE V I E W NO T FO R CO N S T R U C T I O N SYMBOL SIZE SHALL BE 4" SQUARE MIN AT ACCESSIBLE ENTRANCES ALL GENDER MEN'S OR BOY'SWOMEN'S OR GIRL'S 58 - 6 0 " A. F . F . TY P NOTE: 1. SIGN SHALL BE OF ENGRAVED LAMINATED ACRYLIC AND CHARACTER SPACING PER ICC A117.1 - 2009 703.7 WITH SUBSURFACE COLOR AS SELECTED BY ARCHITECT 2. BACKGROUND COLOR OF SIGN TO CONTRAST WITH DOOR COLOR 3. MOUNT SIGN WITH 1" OF CENTRE OF DOOR LEAF 12" DIA 1'-0" 1 ' - 0 " 1'-0" DIA 1'-0 " CONTRASTING COLORS: TRIANGLE OVER BACKGROUND CIRCLE CONTRASTING COLORS: TRIANGLE OVER BACKGROUND CIRCLE PARKING ONLY VAN ACCESSIBLE MINIMUM FINE $250 A.B.+60" (WALL MOUNTED) +80" (POST MOUNTED) NOTE: ALL LETTERING AND SYMBOLS SHALL BE WHITE ON BLUE BACKGROUND. SIGN SHALL BE >/= 70 SQ. IN. IN AREA PARKING ONLY MINIMUM FINE $250 MA Y BE SE P A R A T E PL A C A R D S MO U N T E D TO SI N G L E PO S T MA Y BE SE P A R A T E PL A C A R D S MO U N T E D TO SI N G L E PO S T MA Y BE SE P A R A T E PL A C A R D S MO U N T E D TO SI N G L E PO S T UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE TOWED VEHICLES MAY BE RECLAIMED AT _____________________ OR BY TELEPHONING ________ NOTE: ALL LETTERING 1" HIGH. FILL IN APPROPRIATE INFORMATION AS PERMANENT PART OF THE SIGN 22 " 17" WOMEN MEN UNISEX +58-60" A.F.F. TO C OF SIGN (BRAILLE) L NOTE: 1. SIGN SHALL BE OF ENGRAVED LAMINATED ACRYLIC 2. CHARACTERS AND SPACING PER ICC A117.1 - 2009 703.7 3. MOUNT SIGN AT LATCH SIDE OF DOOR CENTERED IN 18" SPACE 4. CHARACTERS SHOWN IN PARENTHESES SHALL BE UPDATED WITH ACTUAL DESIGNATIONS (RESTROOM) 40 " MI N . 8"6" FI E L D 7" MIN CHARACTERS READING CONSISTENT W/ ROOM NAME ON FLOOR PLANS. POSSIBLE VARIANTS SHOWN ABOVE. REPEAT ALL TEXT IN BRAILLE COMPLIANT WITH ICC A117.1 - 2009 703.4 INTERNATIONAL SYMBOL OF ACCESSIBILITY SYMBOL PER ICC A117.1 - 2009 703.6 CORRESPONDING TO NAME OF ROOM EASED EDGE WITH ROUND CORNERS, TYP (VAN STALL) (TYPICAL AUTO STALL) NO PARKING 1:48 MAX 1: 4 8 MA X 144" MIN (ALT 96" WITH 96" AISLE ACCESS) 60" MIN 108" MIN 21 6 " MI N 36" MAX INTERNATIONAL SIGN OF ACCESSIBILITY 36"x36" WHITE ON BLUE BACKGROUND WHITE LETTERING 12" HIGH. WHITE. BLUE BORDER AND STRIPES BLUE BORDER AND STRIPES WHEELSTOP WHERE OCCURS IDENTIFICATION SIGN WHERE OCCURS. SEE SITE PLANS AND DTL HATCHED LINES SHALL BE PAINTED WITH A COLOR THAT CONTRASTS WITH THE PARKING SURFACE, PREFERABLY BLUE OR WHITE SCALE: 1' = 1'-0"A1 INT'L SIGN OF ACCESSIBILITY SCALE: 1 1/2"= 1'-0"C2 ACCESSIBLE SIGN - DOOR SCALE: 1 1/2"= 1'-0"A2 ACCESSIBILE PARKING SIGN SCALE: 1 1/2"= 1'-0"C1 UNAUTHORIZED VEHICLE SIGN SCALE: 3" = 1'-0"B2 ACCESSIBLE SIGN - WALL SCALE: 1/8" = 1'-0"B1 1/8" GENERAL DETAILS 9.12.23