HomeMy WebLinkAboutDAILY FIELD REPORT - 23-00435 - Precision Precast - New Commercial BldgPRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
1fbaea54224c7895-1701285118768 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
File Name:
23243EDFR09252023JPC
Daily Field Report
Date:
09/25/2023
Project Number:
23-243E
Project Name:
Precision Precast
Client:
Steel Vision Construction
Start Time:
02:00 PM
Contractor:
Steel Vision
Time on Project:
3
Current Weather Conditions:
Sunny/Clear
Wind:
Calm
Ambient Temperature (°F):
65
Results
Inspection Type(s):
Structural Steel and Bolting
Location(s):
Building Steel Framing
Observations/ Remarks:
Arrived on-site and began my observations of the structural steel bolted connections. I observed that the fame
surfaces were in contact with each other, and that the bolts had brought been brought into the snug tightened
position and then tensioned using the turn of the nut. I observe that the base plate bolts have been tightened as
well. I notified the contractor of my observations prior leaving.
Inspector Information
Truck:
ODIN
Mileage From Lab to Project (One Way)
6
Total Mileage
12.00
Inspector's Name:
Jacob Christensen
Inspector's Signature:
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
1fbaea54224c7895-1701285118768 2
Items observed are in general conformance with approved project documents and jurisdictional requirements.
Items observed are NOT in general conformance with approved project documents and jurisdictional requirements.
(Explanation given in Observations and/or Remarks.)
Reviewer's Name:
Jacob Christensen
Reviewer's Signature:
Inspection Images:
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
1fbaea54224c7895-1701285118768 3