HomeMy WebLinkAboutAPPROVED PLAN 3B - 23-00261 - 1203 Castle Pines Rd - PavilionAuthor Name Author Email Author Phone No.:
Larry Beesley Larry.Beesley@rexburg.org 208-372-2176
Description : 1203 Castle Pines Rd - Pavilion
Address : 1203 Castle Pines Rd
Record Type : Residential Accessory Structure
Document Filename : SHEET 3B.pdf
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report
Approved
# 23-00261
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
LANDSCAPE 1 (2)Stamp Larry Beesley : Building Open 1 Approved - Building Inspector
LANDSCAPE 1 (2)Free Text Larry Beesley : Building Open 1 Design Requirements: Minimum Roof Live Load 35# per sq. ft.,
Minimum Wind 85 MPH, Seismic Zone D1
LANDSCAPE 1 (2)Free Text Larry Beesley : Building Open 1 The Metal roofing must comply with IRC R905.10- R905.10.5
LANDSCAPE 1 (2)Free Text Larry Beesley : Building Open 1 The Glulam Beam must be and exterior Beam
Residential Accessory Structure
Approval of plans does not constitute approval of variance from code
Powered by TCPDF (www.tcpdf.org)
4" CONCRETE SLAB
ON 8" MIN ABC
SIMPSON POST
BASE APB88R TO
BE IMBEDDED INTO
CONCRETE (TYP)
12" CONCRETE PILE
TO BE POURED
WITH SLAB
12" THICK FOOTING
WITH 2 #5 REBAR
FOR CHIMNEY TO
BE POURED WITH
SLAB
Design Requirements:
Minimum Roof Live Load
35# per sq. ft., Minimum
Wind 85 MPH, Seismic
Zone D1
T h e G lulam B eam must
b e and ex terior B eam
T h e Metal roofing must comply
w ith IRC R9 0 5.10 - R9 0 5.10 .5