Loading...
HomeMy WebLinkAboutCONCRETE FIELD TEST 2 - 23-00604 - U-Haul - Mini StoragePRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1AD1A109-260B-4057-8AFD-2983A0723C20 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File Name: 22247C03152024MJV Compressive Strength of Concrete Test Specimens Date: 03/15/2024 Project Number: 22-247 Project Name: U-Haul Moving and Storage Client: Bateman-Hall Time on Project: 2 hours Start Time: 08:00 AM Contractor: Bryant Greene Construction Inc. Supplier: KNIFE RIVER Mix Number: C401G426 Concrete Member: Site Elements Required 28 day Strength (psi): 3,500.0 Admixtures: AE200, POLY980, AC534 Entrained Air Spec. (%): 6 +- 1.5 Slump Spec. (inches): 8 Max Results Testing: Set #:Cumulative Test Load Amount: Ticket #: Time Tested: Test Location:Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Slump (in): 1 6.0 22420654 09:00 AM NW side curb on N 3rd E street behind the main Uhaul building. 29 35.580 142.9 63 5 2 Field Technician Information Truck: THOR Total Trip Mileage: 22.00 Tested By: Matthew Valinotti Signature: Items observed are in general conformance with approved project documents and jurisdictional requirements. PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1AD1A109-260B-4057-8AFD-2983A0723C20 2 Items observed are NOT in general conformance with approved project documents and jurisdictional requirements. (Explanation to be given in Observations and/or Remarks.) Observations and/or Remarks: Arrived on job site at 8:45AM. Spoke with Bryant Greene Construction Inc. team to find out best location to store cylinders. Concrete truck arrived at 9:00AM, performed test with Matt H. and Kyle from KNIFE RIVER. Test went according to plan with no errors. Test were reported to contractor. After reporting results, cylinders were made, and were placed in secured cooler for consolidation in proper location. After placing cooler, took photos of location of cylinders and of job site. Cleaned equipment after and left job site. Reviewed By: E. Vail Signature: Inspection Images: Testing: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1AD1A109-260B-4057-8AFD-2983A0723C20 3 Ticket Image: