Compressive Strength of Concrete Test Specimens
Date:
03/15/2024
Project Number:
22-247
Project Name:
U-Haul Moving and Storage
Client:
Bateman-Hall
Time on Project:
2 hours
Start Time:
08:00 AM
Contractor:
Bryant Greene Construction Inc.
Supplier:
KNIFE RIVER
Mix Number:
C401G426
Concrete Member:
Site Elements
Required 28 day Strength (psi):
3,500.0
Admixtures:
AE200, POLY980, AC534
Entrained Air Spec. (%):
6 +- 1.5
Slump Spec. (inches):
8 Max
Results
Testing:
Set #:Cumulative
Test
Load
Amount:
Ticket
#:
Time
Tested:
Test Location:Ambient
Temp.
(°F):
Weight
of
Concrete
(lbs):
Unit
Weight
(PCF):
Concrete
Temp.
(°F):
Entrained
Air
(%):
Slump
(in):
1 6.0 22420654 09:00
AM
NW side curb on N 3rd E street
behind the main Uhaul building.
29 35.580 142.9 63 5 2
Field Technician Information
Truck:
THOR
Total Trip Mileage:
22.00
Tested By:
Matthew Valinotti
Signature:
Items observed are in general conformance with approved project documents and jurisdictional requirements.
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
1AD1A109-260B-4057-8AFD-2983A0723C20 2
Items observed are NOT in general conformance with approved project documents and jurisdictional requirements.
(Explanation to be given in Observations and/or Remarks.)
Observations and/or Remarks:
Arrived on job site at 8:45AM. Spoke with Bryant Greene Construction Inc. team to find out best location to store
cylinders. Concrete truck arrived at 9:00AM, performed test with Matt H. and Kyle from KNIFE RIVER. Test went
according to plan with no errors. Test were reported to contractor. After reporting results, cylinders were made,
and were placed in secured cooler for consolidation in proper location. After placing cooler, took photos of
location of cylinders and of job site. Cleaned equipment after and left job site.
Reviewed By:
E. Vail
Signature:
Inspection Images:
Testing:
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
1AD1A109-260B-4057-8AFD-2983A0723C20 3
Ticket Image: