Loading...
HomeMy WebLinkAboutCONCRETE FIELD TEST - 23-00604 - U-Haul - Mini StoragePRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 40DA2A69-3723-498B-8429-73D041906857 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File Name: 22247C03182024MJV Compressive Strength of Concrete Test Specimens Date: 03/18/2024 Project Number: 22-247 Project Name: U-Haul Moving and Storage Client: Bateman-Hall Time on Project: 2 hours Start Time: 11:30 AM Contractor: Bryant Greene Construction Inc. Supplier: KNIFE RIVER Mix Number: C401G456 Concrete Member: Site Elements Required 28 day Strength (psi): 3,500.0 Admixtures: AE200, POLY980, AC534 Entrained Air Spec. (%): 6 +- 1.5 Slump Spec. (inches): 8 Max Results Testing: Set #:Cumulative Test Load Amount: Ticket #: Time Tested: Test Location:Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Slump (in): 1 6.0 22420704 12:00 PM NW side of N 3rd E sidewalk 49 33.520 134.6 66 7.9 6 Field Technician Information Truck: THOR Total Trip Mileage: 22.00 Tested By: Matthew Valinotti Signature: Items observed are in general conformance with approved project documents and jurisdictional requirements. PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 40DA2A69-3723-498B-8429-73D041906857 2 Items observed are NOT in general conformance with approved project documents and jurisdictional requirements. (Explanation to be given in Observations and/or Remarks.) Observations and/or Remarks: Arrived on job site at 12:00PM and spoke with the team from Bryant Greene Construction Inc. I received the ticket from concrete truck and got information for specs for concrete. Kyle from KNIFE RIVER also joined to check specs and results of tests. All tests met proper specs. Cylinders were made and placed in secure container and secure area away from disturbances. Equipment was then cleaned and left job site. Reviewed By: E. Vail Signature: Inspection Images: Testing: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 40DA2A69-3723-498B-8429-73D041906857 3 Ticket Image: