HomeMy WebLinkAboutCONCRETE FIELD TESTS - 22-00610 - U-Haul - New Commercial Bldg A & B (2)File name: 22247SB06292023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 984FA1A4-8740-4289-9935-8F696982C955 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 7.2 Project Name: U-Haul Moving and Storage Test Location: Building A slab approx. A-17 Client: Bateman-Hall Admixtures: MS-AC-534, MP-322 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-172FI U Date: 6/1/2023 Cylinder Log #: 227 Field Test Results: Set #: 1 Entrained Air (%): 1.5 Concrete Temperature (°F): 68 Ambient Temperature (°F): 45 Unit Weight (PCF): 137.3 Tested By: B. Choffin Date: 6/1/2023 Picked Up By: Jense Christensen Date: 6/2/2023 Time: 11:00 AM Max, Min Temperature 81,59 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/8/2023 12.57 52335 4163 4,000.00 Type 6 File name: 22247SB06292023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 984FA1A4-8740-4289-9935-8F696982C955 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 6/29/2023 4.000 12.57 62,525.0 4974 4,000.0 Type 1 C 28 6/29/2023 4.000 12.57 65,880.0 5241 4,000.0 Type 1 D 28 6/29/2023 4.000 12.57 62,385.0 4963 4,000.0 Type 3 Second Break Average: 5059 Date: 07/01/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB06292023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 6BADBDE5-2377-4C9D-BC80-386104ABC2EA 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 30 Project Name: U-Haul Moving and Storage Test Location: Building A Gridline C:31 Client: Bateman-Hall Admixtures: MS AC 534, MP 322, MA AE 90 Contractor: Bryan Landon Supplier: Walters Ready Mix, Inc. Mix Number: 142-3500 Date: 6/1/2023 Cylinder Log #: 228 Field Test Results: Set #: 2 Entrained Air (%): 5.0 Concrete Temperature (°F): 68 Ambient Temperature (°F): 46 Unit Weight (PCF): 143.4 Tested By: Michael Hammar Date: 6/1/2023 Picked Up By: Jense Christensen Date: 6/2/2023 Time: 11:00 AM Max, Min Temperature 81,59 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 3 6/4/2023 12.57 45380 3610 3,500.00 Type 1 B 7 6/8/2023 12.57 56145 4467 3,500.00 Type 3 File name: 22247SB06292023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 6BADBDE5-2377-4C9D-BC80-386104ABC2EA 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: C 28 6/29/2023 4.000 12.57 65,325.0 5197 3,500.0 Type 3 D 28 6/29/2023 4.000 12.57 65,055.0 5175 3,500.0 Type 3 E 28 6/29/2023 4.000 12.57 65,390.0 5202 3,500.0 Type 1 Second Break Average: 5191 Date: 07/05/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB07072023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. E6944D6B-549B-41AF-83B3-D06304636D23 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10 Project Name: U-Haul Moving and Storage Test Location: Approx. 300 South of Northwest corner of Building B. Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Contractor: Bryan Landon Construction Supplier: Walters Ready Mix, Inc. Mix Number: W172FI 35 Date: 6/9/2023 Cylinder Log #: 244 Field Test Results: Set #: 1 Entrained Air (%): 1.5 Concrete Temperature (°F): 70 Ambient Temperature (°F): 48 Unit Weight (PCF): 145.1 Tested By: B. Choffin Date: 6/9/2023 Picked Up By: Jense Christensen Date: 6/10/2023 Time: 1:00 PM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/16/2023 12.57 50615 4027 4,000.00 Type 6 File name: 22247SB07072023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. E6944D6B-549B-41AF-83B3-D06304636D23 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 7/7/2023 4.000 12.57 60,865.0 4842 4,000.0 Type 2 C 28 7/7/2023 4.000 12.57 62,830.0 4998 4,000.0 Type 4 D 28 7/7/2023 4.000 12.57 64,175.0 5105 4,000.0 Type 3 Second Break Average: 4982 Date: 07/07/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB07122023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1EA35FD2-8B84-4AD8-AF13-29364520E82E 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10 Project Name: U-Haul Moving and Storage Test Location: Valley gutter, 5 ft. south of building 1. Client: Bateman-Hall Admixtures: AE200, POLY980 Contractor: Bryan Landon Construction Supplier: Knife River Mix Number: C401G456 Date: 6/14/2023 Cylinder Log #: 276 Field Test Results: Set #: 1 Entrained Air (%): 6.0 Concrete Temperature (°F): 70 Ambient Temperature (°F): 65 Unit Weight (PCF): 141.1 Tested By: Michael Hammar Date: 6/14/2023 Picked Up By: Jense Christensen Date: 6/15/2023 Time: 1:38 PM Max, Min Temperature 80,60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/21/2023 12.57 44360 3529 3,500.00 Type 6 File name: 22247SB07122023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1EA35FD2-8B84-4AD8-AF13-29364520E82E 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 7/12/2023 4.000 12.57 57,760.0 4595 3,500.0 Type 1 C 28 7/12/2023 4.000 12.57 57,250.0 4554 3,500.0 Type 1 D 28 7/12/2023 4.000 12.57 59,245.0 4713 3,500.0 Type 1 Second Break Average: 4621 Date: 07/12/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB07142023JPC5 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. EE1F418C-5461-4C58-8E7B-E9745E1BE492 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 150 Project Name: U-Haul Moving and Storage Test Location: Building B slab Client: Bateman-Hall Admixtures: MS AC 534, Delvo, MP 322 Contractor: Bryan Landon Construction Supplier: Walters Ready Mix, Inc. Mix Number: 1421 4000 Date: 6/16/2023 Cylinder Log #: 267 Field Test Results: Set #: 5 Entrained Air (%): 1.9 Concrete Temperature (°F): 65 Ambient Temperature (°F): 45 Unit Weight (PCF): 145.8 Tested By: B. Choffin Date: 6/16/2023 Picked Up By: Jense Christensen Date: 6/17/2023 Time: 1:00 PM Max, Min Temperature 80,62 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/23/2023 12.57 56620 4504 4,000.00 Type 3 File name: 22247SB07142023JPC5 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. EE1F418C-5461-4C58-8E7B-E9745E1BE492 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 7/14/2023 4.000 12.57 68,635.0 5460 4,000.0 Type 1 C 28 7/14/2023 4.000 12.57 66,815.0 5315 4,000.0 Type 1 D 28 7/14/2023 4.000 12.57 67,405.0 5362 4,000.0 Type 1 Second Break Average: 5379 Date: 07/14/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB07142023JPC4 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 91662058-6FAC-45D6-8AFD-1B97304B4AA8 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 110 Project Name: U-Haul Moving and Storage Test Location: Building B slab Client: Bateman-Hall Admixtures: MS AC 534, Delvo, MP 322 Contractor: Bryan Landon Construction Supplier: Walters Ready Mix, Inc. Mix Number: 1421 4000 Date: 6/16/2023 Cylinder Log #: 266 Field Test Results: Set #: 4 Entrained Air (%): 1.9 Concrete Temperature (°F): 67 Ambient Temperature (°F): 43 Unit Weight (PCF): 144 Tested By: B. Choffin Date: 6/16/2023 Picked Up By: Jense Christensen Date: 6/17/2023 Time: 1:00 PM Max, Min Temperature 80,62 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/23/2023 12.57 58600 4662 4,000.00 Type 6 File name: 22247SB07142023JPC4 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 91662058-6FAC-45D6-8AFD-1B97304B4AA8 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 7/14/2023 4.000 12.57 69,785.0 5552 4,000.0 Type 1 C 28 7/14/2023 4.000 12.57 68,420.0 5443 4,000.0 Type 3 D 28 7/14/2023 4.000 12.57 68,125.0 5420 4,000.0 Type 1 Second Break Average: 5472 Date: 07/14/2023 Reviewed By: Luke Hammar Signature: File Name 22247C07212023CH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A089E9C4-866A-44CD-A7AD-CC093A9AF3EE 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Ticket #: 06655 Project Name: U-Haul Moving and Storage Test Location: Exterior lab south west corner of building B Concrete Member: Exterior Slab Client: Bateman-Hall Admixtures: DELVO, ML ASR 30, MP 322, MA AE 90 Required 28 day Strength (psi): 4,000.0 Contractor Bryan Landon Supplier: Walters Ready Mix Mix Number: 400-4500 Date: 07/21/2023 Start Time 07:30 AM Time on Project 4 hours 30 minutes Tested By: Caleb Hammar Testing: Set #:Cumulative Test Load Amount: Ticket Image: Ticket #: Time Tested: Test Location: Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Entrained Air Spec. (%): Slump (in): Slump Spec. (in): 2 11.0 06655 09:15 AM Exterior lab south west corner of building B 74 34.860 140.0 78 6.1 6 +- 1.5 5 1/2 8 Max Observations/Remarks: I arrived on site and began observations on the exterior slab for the south east corner of building B. The first truck arrived at the same time that I was performing a test for a different pour and by the time I finished the different pour, the first truck had already finished pouring. I received a sample from the second truck after approximately 5 yards had been expelled from the truck. The truck stopped pouring and waited for the results of the test. With the sample, I performed a concrete field test and made test specimens. I observed that the results File Name 22247C07212023CH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A089E9C4-866A-44CD-A7AD-CC093A9AF3EE 2 of the test were within general conformance to project specifications, and I reported my results to the contractor. I remained on site for the duration of the pour, then left the job-site. Signature:Reviewed By: Luke Hammar Signature: Date: 07/21/2023 Inspection Images File Name 22247C07252023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 3B97E102-5FA5-458F-B2D5-FF45ADFF1D23 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Ticket #: 22413593 Project Name: U-Haul Moving and Storage Test Location: Curb along the east entrance on N Third East Concrete Member: Site Elements Client: Bateman-Hall Admixtures: AE200, POLY980, DELVO Required 28 day Strength (psi): 3,500.0 Contractor Bryant Greene Construction Inc. Supplier: Knife River Mix Number: C401G456 Date: 07/25/2023 Start Time 01:00 PM Time on Project 2.5 hours Tested By: Bryce Choffin Testing: Set #:Cumulative Test Load Amount: Ticket Image: Ticket #: Time Tested: Test Location: Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Entrained Air Spec. (%): Slump (in): Slump Spec. (in): 1 10.0 2241359302:20 PM Curb along the east entrance on N Third East 85 35.500 142.6 78 5 6 +- 1.5 2 3/4 8 Max Observations/Remarks: I arrived on site around 1:50 PM. After finding an area to setup my equipment, I proceeded to inspect the forms where todays pour is and found it to be within project specifications. The first truck arrived around 2:10-2:15 PM. I grabbed my sample after a yard or two was poured out, and began performing my tests. The results were satisfactory. File Name 22247C07252023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 3B97E102-5FA5-458F-B2D5-FF45ADFF1D23 2 I observed the contractor place the material. Signature:Reviewed By: Luke Hammar Signature: Date: 07/25/2023 Inspection Images File Name 22247C07262023MH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. ED417C21-9B51-4759-98E0-D9E4739A65D9 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Ticket #: 22413639 Project Name: U-Haul Moving and Storage Test Location: Site elements, southeast corner of Building B Concrete Member: Site Elements Client: Bateman-Hall Admixtures: AE200, POLY980, DELVO Required 28 day Strength (psi): 3,500.0 Contractor Bryant Greene Construction Inc. Supplier: Knife River Mix Number: C401G426 Date: 07/26/2023 Start Time 07:30 AM Time on Project 2 hours 30 minutes Tested By: Michael Hammar Testing: Set #:Cumulative Test Load Amount: Ticket Image: Ticket #: Time Tested: Test Location: Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Entrained Air Spec. (%): Slump (in): Slump Spec. (in): 1 10.0 2241363908:30 AM Site elements, southeast corner of Building B 65 35.320 141.8 71 5.5 6 +- 1.5 1 1/2 8 Max Observations/Remarks: I arrived on site at approximately 7:55 AM and began preparing my equipment for testing. The truck arrived at approximately 8:25 AM and immediately began preparing to place material. Once a sufficient amount of material had been placed, I collected a sample for testing. The tests I performed for this sample were in general conformance of project specifications and the results were reported to the contractor. File Name 22247C07262023MH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. ED417C21-9B51-4759-98E0-D9E4739A65D9 2 I then cleaned my equipment and entered my vehicle to begin this report. Signature:Reviewed By: Luke Hammar Signature: Date: 07/26/2023 Inspection Images File Name 22247C07262023MH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. ED417C21-9B51-4759-98E0-D9E4739A65D9 3 File name: 22247FB07282023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 8E6978EF-AF72-48EB-B715-3E4DF0AB9860 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11 Project Name: U-Haul Moving and Storage Test Location: Exterior lab south west corner of building B Client: Bateman-Hall Admixtures: DELVO, ML ASR 30, MP 322, MA AE 90 Ticket Number: 6655 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: 400-4500 Date: 7/21/2023 Cylinder Log #: 407 Field Test Results: Set #: 2 Entrained Air (%): 6.1 Concrete Temperature (°F): 78 Ambient Temperature (°F): 74 Unit Weight (PCF): 140 Tested By: Caleb Hammar Time Tested: 04:48 PM Picked Up By: B.Ferguson Date: 7/22/2023 Time: 8:55 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 7/28/2023 4.000 12.57 60,260.0 4794 4,000.0 Type 2 Date: 07/31/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB07282023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 7C026760-4EE5-4A59-89B4-0D822A097EAE 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 5 Project Name: U-Haul Moving and Storage Test Location: Curb north of building B Client: Bateman-Hall Admixtures: AE200, POLY980, DELVO Ticket Number: 102075 Contractor: Bryant Greene Construction Supplier: Knife River Mix Number: C401G426 Date: 7/21/2023 Cylinder Log #: 405 Field Test Results: Set #: 1 Entrained Air (%): 6.3 Concrete Temperature (°F): 73 Ambient Temperature (°F): 74 Unit Weight (PCF): 140.8 Tested By: Caleb Hammar Time Tested: 04:43 PM Picked Up By: B.Ferguson Date: 7/22/2023 Time: 8:46 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 7/28/2023 4.000 12.57 53,595.0 4264 4,000.0 Type 2 Date: 07/31/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 613A4840-717B-4326-B4B4-33AEB4A01447 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB08022023LGS Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Project Name: U-Haul Moving and Storage Test Location: Site elements, southeast corner of Building B Client: Bateman-Hall Admixtures: AE200, POLY980 Ticket Number: 22413639 Contractor: Bryant Greene Construction Inc. Supplier: Knife River Mix Number: C401G426 Date: 7/26/2023 Cylinder Log #: 420 Set #: 1 Entrained Air (%): 5.5 Concrete Temperature (°F): 71 Ambient Temperature (°F): 65 Unit Weight (PCF): 141.8 Tested By: Michael Hammar Time Tested: 08:52 AM Field Test Results: Pick Up Date: 7/27/2023 Picked Up By: E. Vail Time: 1:00 PM Max, Min Temperature: 80, 60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/2/2023 4.000 12.57 47,685.0 3794 3,500.0 Type 2 Date: 08/02/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 4C670F70-A4A4-4970-9677-C71EEC900FE0 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 2224708012023LGS Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Project Name: U-Haul Moving and Storage Test Location: Curb along the east entrance on N Third East Client: Bateman-Hall Admixtures: AE200, POLY980, DELVO Ticket Number: 22413593 Contractor: Bryant Greene Construction Inc. Supplier: Knife River Mix Number: C401G456 Date: 7/25/2023 Cylinder Log #: 416 Set #: 1 Entrained Air (%): 5.0 Concrete Temperature (°F): 78 Ambient Temperature (°F): 85 Unit Weight (PCF): 142.6 Tested By: Bryce Choffin Time Tested: 08:11 AM Field Test Results: Date: 7/26/2023 Picked Up By: B. Choffin Time: 8:19 AM Max, Min Temperature 80, 60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/1/2023 4.000 12.57 57,950.0 4610 3,500.0 Type 2 Date: 08/02/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. D0314F04-D661-4971-9283-2CB77AA95887 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB08032023BC Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10 Project Name: U-Haul Moving and Storage Test Location: Site Elements, southwest side of building B Client: Bateman-Hall Admixtures: AE200, POLY980, DELVO Ticket Number: 22413731 Contractor: Bryant Greene Construction Inc. Supplier: Knife River Mix Number: C401G426 Date: 7/27/2023 Cylinder Log #: 424 Set #: 1 Entrained Air (%): 5.0 Concrete Temperature (°F): 72 Ambient Temperature (°F): 64 Unit Weight (PCF): 143.1 Tested By: Michael Hammar Time Tested: 12:41 PM Field Test Results: Pick Up Date: 7/28/2023 Picked Up By: Michael Hammar Time: 2:47 PM Max, Min Temperature: 80, 60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/3/2023 4.000 12.57 56,360.0 4484 3,500.0 Type 6 Date: 08/03/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 2005B7CA-635D-4484-88F0-792CDF74E8E5 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File Name: 22247C08112023EV Compressive Strength of Concrete Test Specimens Project Number: 22-247 Project Name: U-Haul Moving and Storage Client: Bateman-Hall Contractor: Bryan Landon Construction Date: 08/11/2023 Start Time: 06:45 AM Supplier: Walters Ready Mix Mix Number: 142I 4000 Concrete Member: Interior Slab Required 28 day Strength (psi): 4,000.0 Admixtures: Super P Entrained Air Spec. (%): N/A Slump Spec. (inches): 6 Max Testing Results Testing: Set #:Cumulative Test Load Amount: Ticket Image: Ticket #: Time Tested: Test Location: Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Entrained Air Spec. (%): Slump (in): Slump Spec. (in): 1 121.0 7267 08:00 AM East half of Building A, 2nd floor. 61 34.760 139.6 72 1.7 N/A 6 6 Max Field Technician Information Date: 08/11/2023 Total Trip Mileage: 22.00 Items observed are in general conformance with approved project documents and jurisdictional requirements. Items observed are NOT in general conformance with approved project documents and jurisdictional requirements. (Explanation to be given in Observations and/ or Remarks.) Tested By: Eric Vail Signature: Observations and/or Remarks: I arrived on site and checked in with Mike Massey (Bateman-Hall) and Ryan Murdock (Bryan Landon Construction) and was able to test the last truck of the day. PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 2005B7CA-635D-4484-88F0-792CDF74E8E5 2 After a yard was displaced, I was able to obtain a sample for testing. I tested for air, slump, and temp. Those results were within spec and reported back to the appropriate parties. After making strength cylinders I cleaned up my gear and observed the remainder of the pour. Reviewed By: Luke Hammar Date: 08/11/2023 Signature: Inspection Images: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 7706B1FB-428E-4B15-B01A-675968CBD665 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File Name: 22247C08172023LS Compressive Strength of Concrete Test Specimens Project Number: 22-247 Project Name: U-Haul Moving and Storage Client: Bateman-Hall Contractor: BL Construction Date: 08/17/2023 Time on Project: 3 hours Start Time: 03:45 AM Supplier: Walter’s Ready Mix Mix Number: 1421 4000 Concrete Member: Interior Slab Required 28 day Strength (psi): 4000.0 Admixtures: MS WC 534, DELVO, MP 322, SUPER PLASTISIZER Entrained Air Spec. (%): N/A Slump Spec. (inches): 6 Max Testing Results Testing: Set #:Cumulative Test Load Amount: Ticket Image: Ticket #: Time Tested: Test Location: Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Entrained Air Spec. (%): Slump (in): Slump Spec. (in): 1 10.0 07417 04:30 AM Interior floor, 2nd level 55 36.400 146.2 75 1.9 N/A 7.5 inches 6 Max 2 50.0 07421 05:15 AM 2nd floor interior slab 55 35.980 144.5 73 2.2 N/A 8 inches 6 Max 3 100.0 07427 06:00 AM 2nd floor interior sub flooring 53 36.360 146.0 71 1.8 N/A 7.75 inches 6 Max Field Technician Information Date: 08/17/2023 Total Trip Mileage: Tested By: Leland Stiener Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 7706B1FB-428E-4B15-B01A-675968CBD665 2 20.00 Items observed are in general conformance with approved project documents and jurisdictional requirements. Items observed are NOT in general conformance with approved project documents and jurisdictional requirements. (Explanation to be given in Observations and/ or Remarks.) Observations and/or Remarks: I arrived on site at around 3:45am and began setting up for concrete testing. The first trucked arrived at around 4:30am and I began testing. I tested three times, at 10 yards, 50 yards, and 100 yards. As I completed my tests I was able to report my results to the contractor and supplier. I made strength specimens for each truck that I tested. Upon completion of my last test I cleaned my equipment and wrote this report. Reviewed By: Luke Hammar Date: 08/17/2023 Signature: Inspection Images: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 0DAB1752-2A44-4C7E-A978-5FBAC8A38735 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB08182023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 121.0 Project Name: U-Haul Moving and Storage Test Location: East half of Building A, 2nd floor. Client: Bateman-Hall Admixtures: Super P Ticket Number: 7267 Contractor: Bryan Landon Construction Supplier: Walters Ready Mix Mix Number: 142I 4000 Date: 8/11/2023 Cylinder Log #: 452 Set #: 1 Entrained Air (%): 1.7 Concrete Temperature (°F): 72 Ambient Temperature (°F): 61 Unit Weight (PCF): 139.6 Tested By: Eric Vail Time Tested: 01:35 PM Field Test Results: Pick Up Date: 8/11/2023 Picked Up By: Jense Christensen Time: 9:00 AM Max, Min Temperature: 80,60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/18/2023 4.000 12.57 59,265.0 4715 4,000.0 Type 2 Date: 08/18/2023 Reviewed By: E. Vail Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. BFBA0F0B-4573-401C-9371-1CB698C353B2 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB08182023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Project Name: U-Haul Moving and Storage Test Location: Exterior lab south west corner of building B Client: Bateman-Hall Admixtures: DELVO, ML ASR 30, MP 322, MA AE 90 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: 400-4500 Date: 7/21/2023 Cylinder Log #: 407 Set #: 2 Entrained Air (%): 6.1 Concrete Temperature (°F): 78 Ambient Temperature (°F): 74 Unit Weight (PCF): 140.0 Tested By: Caleb Hammar Date: 7/21/2023 Field Test Results: Picked Up By: B.Ferguson Pick Up Date: 7/22/2023 Pick Up Time: 8:55 AM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 7/28/2023 12.57 60260 4794 4,000.00 Type 2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. BFBA0F0B-4573-401C-9371-1CB698C353B2 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 8/18/2023 4.000 12.57 71,695.0 5704 4,000.0 Type 1 C 28 8/18/2023 4.000 12.57 73,950.0 5883 4,000.0 Type 6 D 28 8/18/2023 4.000 12.57 75,645.0 6018 4,000.0 Type 1 Second Break Average: 5868 Date: 08/18/2023 Reviewed By: E. Vail Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 10758E1C-B064-4DAE-BE4A-F547CB059112 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB08182023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 5.0 Project Name: U-Haul Moving and Storage Test Location: Curb north of building B Client: Bateman-Hall Admixtures: AE200, POLY980, DELVO Contractor: Bryant Greene Construction Supplier: Knife River Mix Number: C401G426 Date: 7/21/2023 Cylinder Log #: 405 Set #: 1 Entrained Air (%): 6.3 Concrete Temperature (°F): 73 Ambient Temperature (°F): 74 Unit Weight (PCF): 140.8 Tested By: Caleb Hammar Date: 7/21/2023 Field Test Results: Picked Up By: B.Ferguson Pick Up Date: 7/22/2023 Pick Up Time: 8:46 AM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 7/28/2023 12.57 53595 4264 4,000.00 Type 2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 10758E1C-B064-4DAE-BE4A-F547CB059112 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 8/18/2023 4.000 12.57 64,695.0 5147 4,000.0 Type 3 C 28 8/18/2023 4.000 12.57 65,135.0 5182 4,000.0 Type 6 D 28 8/18/2023 4.000 12.57 63,925.0 5086 4,000.0 Type 6 Second Break Average: 5138 Date: 08/18/2023 Reviewed By: E. Vail Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 294143FC-18AD-4B2F-AFEC-E3E11EB21D41 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB08222023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Project Name: U-Haul Moving and Storage Test Location: Curb along the east entrance on N Third East Client: Bateman-Hall Admixtures: AE200, POLY980, DELVO Contractor: Bryant Greene Construction Inc. Supplier: Knife River Mix Number: C401G456 Date: 7/25/2023 Cylinder Log #: 416 Set #: 1 Entrained Air (%): 5.0 Concrete Temperature (°F): 78 Ambient Temperature (°F): 85 Unit Weight (PCF): 142.6 Tested By: Bryce Choffin Date: 7/25/2023 Field Test Results: Picked Up By: B. Choffin Pick Up Date: 7/26/2023 Pick Up Time: 8:19 AM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/1/2023 12.57 57950 4610 3,500.00 Type 2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 294143FC-18AD-4B2F-AFEC-E3E11EB21D41 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 8/22/2023 4.000 12.57 65175.0 5185 3500.0 Type 1 C 28 8/22/2023 4.000 12.57 66120.0 5260 3500.0 Type 1 D 28 8/22/2023 4.000 12.57 68705.0 5466 3500.0 Type 1 Second Break Average: 5304 Date: 08/23/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 66244CC8-DAD7-45F6-B3C9-9F76BD375116 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB08232023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Project Name: U-Haul Moving and Storage Test Location: Site elements, southeast corner of Building B Client: Bateman-Hall Admixtures: AE200, POLY980 Contractor: Bryant Greene Construction Inc. Supplier: Knife River Mix Number: C401G426 Date: 7/26/2023 Cylinder Log #: 420 Set #: 1 Entrained Air (%): 5.5 Concrete Temperature (°F): 71 Ambient Temperature (°F): 65 Unit Weight (PCF): 141.8 Tested By: Michael Hammar Date: 7/26/2023 Field Test Results: Picked Up By: E. Vail Pick Up Date: 7/27/2023 Pick Up Time: 1:00 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/2/2023 12.57 47685 3794 3,500.00 Type 2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 66244CC8-DAD7-45F6-B3C9-9F76BD375116 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 8/23/2023 4.000 12.57 62560.0 4977 3500.0 Type 1 C 28 8/23/2023 4.000 12.57 63515.0 5053 3500.0 Type 3 D 28 8/23/2023 4.000 12.57 65330.0 5197 3500.0 Type 3 Second Break Average: 5076 Date: 08/23/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. DBC9D8EF-ACE3-46C9-866D-02E20C287043 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File Name: 22247C08252023LS Compressive Strength of Concrete Test Specimens Date: 08/25/2023 Project Number: 22-247 Project Name: U-Haul Moving and Storage Client: Bateman-Hall Time on Project: 3 hours Start Time: 04:00 AM Contractor: Bryan Landon Construction Supplier: Walter’s Ready Mix, Inc Mix Number: 142I 4000 Concrete Member: Interior Slab Required 28 day Strength (psi): 4000.0 Admixtures: MS AC 534, DELVO, MP 322, SUPERPLASTISIZER Entrained Air Spec. (%): N/A Slump Spec. (inches): 6 Max Results Testing: Set #:Cumulative Test Load Amount: Ticket #: Time Tested: Test Location:Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Slump (in): 1 10.0 07698 04:30 AM Interior subfloor 2nd story 53 36.060 144.8 70 2.5 8 2 50.0 07702 05:15 AM 2nd level interior subfloor 53 36.640 147.1 73 2.1 7 1/2 3 110.0 07708 06:15 AM 2 level interior subfloor 50 36.710 147.4 69 1.7 8 1/4 Field Technician Information Truck: THOR Total Trip Mileage: 20.00 Tested By: Leland Steiner Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. DBC9D8EF-ACE3-46C9-866D-02E20C287043 2 Items observed are in general conformance with approved project documents and jurisdictional requirements. Items observed are NOT in general conformance with approved project documents and jurisdictional requirements. (Explanation to be given in Observations and/or Remarks.) Observations and/or Remarks: I arrived on site around 4:00 AM and began my inspections. I then began setting up my equipment for my field tests. Throughout the pour, I tested the concrete 3 different times, 50 yards apart. After each test I reported my results to the contractor and made strength specimens. Upon completion I cleaned my gear and observed the duration of the concrete placement. Reviewed By: Luke Hammar Signature: Inspection Images: Testing: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. DBC9D8EF-ACE3-46C9-866D-02E20C287043 3 Ticket Image: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. DBC9D8EF-ACE3-46C9-866D-02E20C287043 4 Ticket Image: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. DBC9D8EF-ACE3-46C9-866D-02E20C287043 5 Ticket Image: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1D3F0C75-F8FF-4F23-AA31-BD2F4350466F 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB08242023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Project Name: U-Haul Moving and Storage Test Location: Site Elements, southwest side of building B Client: Bateman-Hall Admixtures: AE200, POLY980, DELVO Contractor: Bryant Greene Construction Inc. Supplier: Knife River Mix Number: C401G426 Date: 7/27/2023 Cylinder Log #: 424 Set #: 1 Entrained Air (%): 5.0 Concrete Temperature (°F): 72 Ambient Temperature (°F): 64 Unit Weight (PCF): 143.1 Tested By: Michael Hammar Date: 7/27/2023 Field Test Results: Picked Up By: Michael Hammar Pick Up Date: 7/28/2023 Pick Up Time: 2:47 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/3/2023 12.57 56360 4484 3,500.00 Type 6 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1D3F0C75-F8FF-4F23-AA31-BD2F4350466F 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 8/24/2023 4.000 12.57 72635.0 5778 3500.0 Type 1 C 28 8/24/2023 4.000 12.57 75045.0 5970 3500.0 Type 1 D 28 8/24/2023 4.000 12.57 72950.0 5804 3500.0 Type 1 Second Break Average: 5851 Date: 08/28/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 3EAD8823-2DC4-4578-A121-9C5B53F4D3AA 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB08242023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Project Name: U-Haul Moving and Storage Test Location: Interior floor, 2nd level Client: Bateman-Hall Admixtures: MS WC 534, DELVO, MP 322, SUPER PLASTISIZER Ticket Number: 7417 Contractor: BL Construction Supplier: Walters Ready Mix Mix Number: 1421 4000 Date: 8/17/2023 Cylinder Log #: 469 Set #: 1 Entrained Air (%): 1.9 Concrete Temperature (°F): 75 Ambient Temperature (°F): 55 Unit Weight (PCF): 146.2 Tested By: Leland Stiener Time Tested: 08:50 AM Field Test Results: Pick Up Date: 8/18/2023 Picked Up By: Matthew Hammar Time: 10:10 AM Max, Min Temperature: 80, 60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/24/2023 4.000 12.57 58710.0 4671 4000.0 Type 1 Date: 08/28/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F7DE7675-585F-408C-8D7A-115F2C57041B 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB08242023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 100.0 Project Name: U-Haul Moving and Storage Test Location: 2nd floor interior sub flooring Client: Bateman-Hall Admixtures: MS WC 534, DELVO, MP 322, SUPER PLASTISIZER Ticket Number: 7427 Contractor: BL Construction Supplier: Walters Ready Mix Mix Number: 1421 4000 Date: 8/17/2023 Cylinder Log #: 471 Set #: 3 Entrained Air (%): 1.8 Concrete Temperature (°F): 71 Ambient Temperature (°F): 53 Unit Weight (PCF): 146.0 Tested By: Leland Stiener Time Tested: 08:45 AM Field Test Results: Pick Up Date: 8/18/2023 Picked Up By: Matthew Hammar Time: 10:40 AM Max, Min Temperature: 80, 60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/24/2023 4.000 12.57 59705.0 4750 4000.0 Type 3 Date: 08/28/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. BC630ABC-512D-4FEB-A3A1-2AC0369CA4FF 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB08242023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 50.0 Project Name: U-Haul Moving and Storage Test Location: 2nd floor interior slab Client: Bateman-Hall Admixtures: MS WC 534, DELVO, MP 322, SUPER PLASTISIZER Ticket Number: 7421 Contractor: BL Construction Supplier: Walters Ready Mix Mix Number: 1421 4000 Date: 8/17/2023 Cylinder Log #: 470 Set #: 2 Entrained Air (%): 2.2 Concrete Temperature (°F): 73 Ambient Temperature (°F): 55 Unit Weight (PCF): 144.5 Tested By: Leland Stiener Time Tested: 08:42 AM Field Test Results: Pick Up Date: 8/18/2023 Picked Up By: Matthew Hammar Time: 10:29 AM Max, Min Temperature: 80, 60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/24/2023 4.000 12.57 57330.0 4561 4000.0 Type 6 Date: 08/28/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 6FF3DC7E-E9A4-40B9-B2F5-D76C60FBAC9C 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB0912023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 110.0 Project Name: U-Haul Moving and Storage Test Location: 2 level interior subfloor Client: Bateman-Hall Admixtures: MS AC 534, DELVO, MP 322, SUPERPLASTISIZER Ticket Number: 7708 Contractor: Bryan Landon Construction Supplier: Walters Ready Mix, Inc Mix Number: 142I 4000 Date: 8/25/2023 Cylinder Log #: 501 Set #: 3 Entrained Air (%): 1.7 Concrete Temperature (°F): 69 Ambient Temperature (°F): 50 Unit Weight (PCF): 147.4 Tested By: Leland Steiner Time Tested: 08:13 AM Field Test Results: Pick Up Date: 8/26/2023 Picked Up By: L. Steiner Time: 1:53 PM Max, Min Temperature: 80,60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/1/2023 4.000 12.57 64890.0 5162 4000.0 Type 1 Date: 09/01/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 900CB26B-0CEB-4122-9899-AB8D69A37368 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB0912023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 50.0 Project Name: U-Haul Moving and Storage Test Location: 2nd level interior subfloor Client: Bateman-Hall Admixtures: MS AC 534, DELVO, MP 322, SUPERPLASTISIZER Ticket Number: 7702 Contractor: Bryan Landon Construction Supplier: Walters Ready Mix, Inc Mix Number: 142I 4000 Date: 8/25/2023 Cylinder Log #: 500 Set #: 2 Entrained Air (%): 2.1 Concrete Temperature (°F): 73 Ambient Temperature (°F): 53 Unit Weight (PCF): 147.1 Tested By: Leland Steiner Time Tested: 08:09 AM Field Test Results: Pick Up Date: 8/26/2023 Picked Up By: L. Steiner Time: 1:30 PM Max, Min Temperature: 80,60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/1/2023 4.000 12.57 58845.0 4681 4000.0 Type 3 Date: 09/01/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. D923B3A7-F3D9-4B7A-BC1F-75E955B79968 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB0912023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Project Name: U-Haul Moving and Storage Test Location: Interior subfloor 2nd story Client: Bateman-Hall Admixtures: MS AC 534, DELVO, MP 322, SUPERPLASTISIZER Ticket Number: 7698 Contractor: Bryan Landon Construction Supplier: Walters Ready Mix, Inc Mix Number: 142I 4000 Date: 8/25/2023 Cylinder Log #: 499 Set #: 1 Entrained Air (%): 2.5 Concrete Temperature (°F): 70 Ambient Temperature (°F): 53 Unit Weight (PCF): 144.8 Tested By: Leland Steiner Time Tested: 08:03 AM Field Test Results: Pick Up Date: 8/26/2023 Picked Up By: L. Steiner Time: 1:20 PM Max, Min Temperature: 76,60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/1/2023 4.000 12.57 58270.0 4636 4000.0 Type 2 Date: 09/01/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. EF2B11CA-2D47-49F3-8D42-874A97563ABC 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File Name: 23247C09112023BF Compressive Strength of Concrete Test Specimens Date: 09/11/2023 Project Number: 22-247 Project Name: U-Haul Moving and Storage Client: Bateman-Hall Time on Project: 4.5 Start Time: 04:15 AM Contractor: Bryan Landon Construction Supplier: Walters Mix Number: 1421 4000 Concrete Member: Interior Slab Required 28 day Strength (psi): 4,000.0 Admixtures: N/A Entrained Air Spec. (%): N/A Slump Spec. (inches): 6 Max Results Testing: Set #:Cumulative Test Load Amount: Ticket #: Time Tested: Test Location:Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Slump (in): 1 10.0 08102 05:00 AM Second floor interior slab 65 36.660 147.2 72 1.5 8 2 60.0 08107 05:30 AM Second floor interior slab 65 36.560 146.8 70 2 8 3 110.0 08113 06:00 AM Second floor interior slab 68 36.240 145.5 71 2 8 Field Technician Information Truck: GROOT Total Trip Mileage: 22.00 Tested By: Bryton Ferguson Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. EF2B11CA-2D47-49F3-8D42-874A97563ABC 2 Items observed are in general conformance with approved project documents and jurisdictional requirements. Items observed are NOT in general conformance with approved project documents and jurisdictional requirements. (Explanation to be given in Observations and/or Remarks.) Observations and/or Remarks: Arrived on site, spoke with Ryan Murdock (Bryan Landon Construction) regarding where would be best for me to set up my equipment, they pumped 120 yards with a pump truck to the second floor slab. My tests were within general acceptance of the job specific specifications. Informed Ryan of results. Reviewed By: E. Vail Signature: Inspection Images: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. EF2B11CA-2D47-49F3-8D42-874A97563ABC 3 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. EF2B11CA-2D47-49F3-8D42-874A97563ABC 4 Testing: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. EF2B11CA-2D47-49F3-8D42-874A97563ABC 5 Ticket Image: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. EF2B11CA-2D47-49F3-8D42-874A97563ABC 6 Ticket Image: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. EF2B11CA-2D47-49F3-8D42-874A97563ABC 7 Ticket Image: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 5BA361B7-4104-4DE8-BA79-F8871C312801 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB09082023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 121.0 Project Name: U-Haul Moving and Storage Test Location: East half of Building A, 2nd floor. Client: Bateman-Hall Admixtures: Super P Contractor: Bryan Landon Construction Supplier: Walters Ready Mix Mix Number: 142I 4000 Date: 8/11/2023 Cylinder Log #: 452 Set #: 1 Entrained Air (%): 1.7 Concrete Temperature (°F): 72 Ambient Temperature (°F): 61 Unit Weight (PCF): 139.6 Tested By: Eric Vail Date: 8/11/2023 Field Test Results: Picked Up By: Jense Christensen Pick Up Date: 8/11/2023 Pick Up Time: 9:00 AM Max, Min Temperature: 80,60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/18/2023 12.57 59265 4715 4,000.00 Type 2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 5BA361B7-4104-4DE8-BA79-F8871C312801 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 9/8/2023 4.000 12.57 71,830.0 5714 4,000.0 Type 3 C 28 9/8/2023 4.000 12.57 74,230.0 5905 4,000.0 Type 3 D 28 9/8/2023 4.000 12.57 73,755.0 5868 4,000.0 Type 3 Second Break Average: 5829 Date: 09/11/2023 Reviewed By: E. Vail Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 832590EE-7763-4424-B87B-F384FEA0060C 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File Name: 22247C09132023BF Compressive Strength of Concrete Test Specimens Date: 09/13/2023 Project Number: 22-247 Project Name: U-Haul Moving and Storage Client: Bateman-Hall Time on Project: 4 Hours Start Time: 06:46 AM Contractor: Bryan Landon Construction Supplier: Walters Mix Number: 1421 4000 Concrete Member: Interior Slab Required 28 day Strength (psi): 4000.0 Admixtures: N/A Entrained Air Spec. (%): N/A Slump Spec. (inches): 6 Max Results Testing: Set #:Cumulative Test Load Amount: Ticket #: Time Tested: Test Location:Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Slump (in): 1 10.0 08180 04:10 AM Gridlines 27-E page S2 of plans 68 36.280 145.7 70 1.25 7.75 2 70.0 08186 05:15 AM Gridlines 24-D page S2 of plans 68 36.340 145.9 70 1.5 8 3 110.0 08190 05:40 AM Gridlines 26-B page S2 of plans 70 36.500 146.6 70 2 8 Field Technician Information Truck: GROOT Total Trip Mileage: 22.00 Tested By: Bryton Ferguson Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 832590EE-7763-4424-B87B-F384FEA0060C 2 Items observed are in general conformance with approved project documents and jurisdictional requirements. Items observed are NOT in general conformance with approved project documents and jurisdictional requirements. (Explanation to be given in Observations and/or Remarks.) Observations and/or Remarks: I arrived on site and located where the concrete placement was to take place. I set up my equipment and pulled my first sample. I performed a concrete field test and reported my results to conractor. I then made stregth specimens. I repeated this process two more time every 50 yards of concrete placed. All results were reported to the contractor. Upon completion of my final field test for the day I cleaned my equipment and observed the remainder of the pour. Reviewed By: Luke Hammar Signature: Inspection Images: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 832590EE-7763-4424-B87B-F384FEA0060C 3 Testing: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 832590EE-7763-4424-B87B-F384FEA0060C 4 Ticket Image: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 832590EE-7763-4424-B87B-F384FEA0060C 5 Ticket Image: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 832590EE-7763-4424-B87B-F384FEA0060C 6 Ticket Image: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F0794576-A01B-4624-BAE3-C09753602299 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22w47SB09142023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 100.0 Project Name: U-Haul Moving and Storage Test Location: 2nd floor interior sub flooring Client: Bateman-Hall Admixtures: MS WC 534, DELVO, MP 322, SUPER PLASTISIZER Contractor: BL Construction Supplier: Walters Ready Mix Mix Number: 1421 4000 Date: 8/17/2023 Cylinder Log #: 471 Set #: 3 Entrained Air (%): 1.8 Concrete Temperature (°F): 71 Ambient Temperature (°F): 53 Unit Weight (PCF): 146.0 Tested By: Leland Stiener Date: 8/17/2023 Field Test Results: Picked Up By: Matthew Hammar Pick Up Date: 8/18/2023 Pick Up Time: 10:40 AM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/24/2023 12.57 59705 4750 4,000.00 Type 3 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F0794576-A01B-4624-BAE3-C09753602299 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 9/14/2023 4.000 12.57 75570.0 6012 4000.0 Type 6 C 28 9/14/2023 4.000 12.57 74885.0 5957 4000.0 Type 2 D 28 9/14/2023 4.000 12.57 77136.0 6137 4000.0 Type 1 Second Break Average: 6035 Date: 09/18/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 9A4D5FE1-F58F-456B-82AC-8ECC6161C41E 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB09142023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Project Name: U-Haul Moving and Storage Test Location: Interior floor, 2nd level Client: Bateman-Hall Admixtures: MS WC 534, DELVO, MP 322, SUPER PLASTISIZER Contractor: BL Construction Supplier: Walters Ready Mix Mix Number: 1421 4000 Date: 8/17/2023 Cylinder Log #: 469 Set #: 1 Entrained Air (%): 1.9 Concrete Temperature (°F): 75 Ambient Temperature (°F): 55 Unit Weight (PCF): 146.2 Tested By: Leland Stiener Date: 8/17/2023 Field Test Results: Picked Up By: Matthew Hammar Pick Up Date: 8/18/2023 Pick Up Time: 10:10 AM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/24/2023 12.57 58710 4671 4,000.00 Type 1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 9A4D5FE1-F58F-456B-82AC-8ECC6161C41E 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 9/14/2023 4.000 12.57 75430.0 6001 4000.0 Type 1 C 28 9/14/2023 4.000 12.57 72180.0 5742 4000.0 Type 6 D 28 9/14/2023 4.000 12.57 72300.0 5752 4000.0 Type 6 Second Break Average: 5832 Date: 09/18/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 5B47D9E2-2F58-4161-A979-7EB472455835 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB09142023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 50.0 Project Name: U-Haul Moving and Storage Test Location: 2nd floor interior slab Client: Bateman-Hall Admixtures: MS WC 534, DELVO, MP 322, SUPER PLASTISIZER Contractor: BL Construction Supplier: Walters Ready Mix Mix Number: 1421 4000 Date: 8/17/2023 Cylinder Log #: 470 Set #: 2 Entrained Air (%): 2.2 Concrete Temperature (°F): 73 Ambient Temperature (°F): 55 Unit Weight (PCF): 144.5 Tested By: Leland Stiener Date: 8/17/2023 Field Test Results: Picked Up By: Matthew Hammar Pick Up Date: 8/18/2023 Pick Up Time: 10:29 AM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/24/2023 12.57 57330 4561 4,000.00 Type 6 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 5B47D9E2-2F58-4161-A979-7EB472455835 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 9/14/2023 4.000 12.57 70175.0 5583 4000.0 Type 1 C 28 9/14/2023 4.000 12.57 68570.0 5455 4000.0 Type 6 D 28 9/14/2023 4.000 12.57 72035.0 5731 4000.0 Type 3 Second Break Average: 5590 Date: 09/18/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. DF3D68A6-7FD9-4B29-8DE2-728ABD60E9CE 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File Name: 22247C09202023EV Compressive Strength of Concrete Test Specimens Date: 09/20/2023 Project Number: 22-247 Project Name: U-Haul Moving and Storage Client: Bateman-Hall Time on Project: 3 hours Start Time: 09:00 AM Contractor: Bryant Greene Construction Supplier: Knife River Mix Number: C401G456 Concrete Member: Site Elements Required 28 day Strength (psi): 3,500.0 Admixtures: Air entrainment Entrained Air Spec. (%): 6 +- 1.5 Slump Spec. (inches): 8 Max Results Testing: Set #:Cumulative Test Load Amount: Ticket #: Time Tested: Test Location:Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Slump (in): 1 9.0 22416626 11:00 AM NW most sidewalk. NW corner of location. 63 34.260 137.6 65 6 7 1/4 Field Technician Information Truck: DEADPOOL Total Trip Mileage: 30.00 Tested By: Eric Vail Signature: Items observed are in general conformance with approved project documents and jurisdictional requirements. Items observed are NOT in general conformance with approved project documents and jurisdictional requirements. PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. DF3D68A6-7FD9-4B29-8DE2-728ABD60E9CE 2 (Explanation to be given in Observations and/or Remarks.) Observations and/or Remarks: I arrived on site and spoke with Mike Massey of Bateman Hall who told me what they planned on pouring today. He mentioned that concrete was about an hour late so I had time to look over the forms and rebar. The rebar appeared to be in accordance with the specs and the forms were free of debris and appeared to be structurally sound. Eventually the concrete showed up and I was able to test for air, slump, and temp. They were within spec and I reported that back to the appropriate parties. After making strength cylinders I cleaned up my gear and left. Reviewed By: E. Vail Signature: Inspection Images: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. DF3D68A6-7FD9-4B29-8DE2-728ABD60E9CE 3 Testing: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. DF3D68A6-7FD9-4B29-8DE2-728ABD60E9CE 4 Ticket Image: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. CDD64F8F-838B-4CB8-9D42-7837C86B482F 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB09192023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 60 Project Name: U-Haul Moving and Storage Test Location: Second floor interior slab Client: Bateman-Hall Admixtures: N/A Ticket Number: 8107 Contractor: Bryan Landon Construction Supplier: Walters Mix Number: 1421 4000 Date: 9/11/2023 Cylinder Log #: 543 Set #: 2 Entrained Air (%): 2.0 Concrete Temperature (°F): 70 Ambient Temperature (°F): 69 Unit Weight (PCF): 146.8 Tested By: Bryton Ferguson Time Tested: 02:42 PM Field Test Results: Pick Up Date: 9/12/2023 Picked Up By: Matthew Hammar Time: 2:19 PM Max, Min Temperature: 80, 60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/18/2023 4.000 12.57 64,645.0 5143 4,000.0 Type 3 Date: 09/22/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. DED0B59B-4F43-4CF3-AE7B-E02D53065A29 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB09192023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 110 Project Name: U-Haul Moving and Storage Test Location: Second floor interior slab Client: Bateman-Hall Admixtures: N/A Ticket Number: 8113 Contractor: Bryan Landon Construction Supplier: Walters Mix Number: 1421 4000 Date: 9/11/2023 Cylinder Log #: 544 Set #: 3 Entrained Air (%): 2.0 Concrete Temperature (°F): 71 Ambient Temperature (°F): 69 Unit Weight (PCF): 145.5 Tested By: Bryton Ferguson Time Tested: 02:39 PM Field Test Results: Pick Up Date: 9/12/2023 Picked Up By: Matthew Hammar Time: 2:29 PM Max, Min Temperature: 80, 60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/18/2023 4.000 12.57 64,440.0 5126 4,000.0 Type 3 Date: 09/22/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 50E5F95A-EBDC-489B-B6FB-26DB102F17FD 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB09192023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10 Project Name: U-Haul Moving and Storage Test Location: Second floor interior slab Client: Bateman-Hall Admixtures: N/A Ticket Number: 8102 Contractor: Bryan Landon Construction Supplier: Walters Mix Number: 1421 4000 Date: 9/11/2023 Cylinder Log #: 542 Set #: 1 Entrained Air (%): 1.5 Concrete Temperature (°F): 72 Ambient Temperature (°F): 69 Unit Weight (PCF): 147.2 Tested By: Bryton Ferguson Time Tested: 02:35 PM Field Test Results: Pick Up Date: 9/12/2023 Picked Up By: Matthew Hammar Time: 2:08 PM Max, Min Temperature: 80, 60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/18/2023 4.000 12.57 63,845.0 5079 4,000.0 Type 6 Date: 09/22/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 8E587498-6A67-48E3-8DC0-6EA1CDEFBA03 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB09202023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Project Name: U-Haul Moving and Storage Test Location: Gridlines 27-E page S2 of plans Client: Bateman-Hall Admixtures: MS AC 534, DELVO, MP 322, SUPERPLASTISIZER Ticket Number: 8180 Contractor: Bryan Landon Construction Supplier: Walters Mix Number: 1421 4000 Date: 9/13/2023 Cylinder Log #: 554 Set #: 1 Entrained Air (%): 1.2 Concrete Temperature (°F): 70 Ambient Temperature (°F): 68 Unit Weight (PCF): 145.7 Tested By: Bryton Ferguson Time Tested: 08:29 AM Field Test Results: Pick Up Date: 9/14/2023 Picked Up By: Matthew Hammar Time: 1:01 PM Max, Min Temperature: 80, 60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/20/2023 4.000 12.57 49275.0 3920 3500.0 Type 6 Date: 09/22/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 75511E1F-9EDA-4454-AA56-94DCBF0B6A52 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB09202023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 70.0 Project Name: U-Haul Moving and Storage Test Location: Gridlines 24-D page S2 of plans Client: Bateman-Hall Admixtures: MS AC 534, DELVO, MP 322, SUPERPLASTISIZER Ticket Number: 8186 Contractor: Bryan Landon Construction Supplier: Walters Mix Number: 1421 4000 Date: 9/13/2023 Cylinder Log #: 555 Set #: 2 Entrained Air (%): 1.5 Concrete Temperature (°F): 70 Ambient Temperature (°F): 68 Unit Weight (PCF): 145.9 Tested By: Bryton Ferguson Time Tested: 08:24 AM Field Test Results: Pick Up Date: 9/14/2023 Picked Up By: Matthew Hammar Time: 1:30 PM Max, Min Temperature: 80, 60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/20/2023 4.000 12.57 54845.0 4363 3500.0 Type 1 Date: 09/22/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 86B14DB9-E53D-4EE5-8B4D-35E6A80B47C0 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB09202023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 110.0 Project Name: U-Haul Moving and Storage Test Location: Gridlines 26-B page S2 of plans Client: Bateman-Hall Admixtures: MS AC 534, DELVO, MP 322, SUPERPLASTISIZER Ticket Number: 8190 Contractor: Bryan Landon Construction Supplier: Walters Mix Number: 1421 4000 Date: 9/13/2023 Cylinder Log #: 556 Set #: 3 Entrained Air (%): 2.0 Concrete Temperature (°F): 70 Ambient Temperature (°F): 70 Unit Weight (PCF): 146.6 Tested By: Bryton Ferguson Time Tested: 08:20 AM Field Test Results: Pick Up Date: 9/14/2023 Picked Up By: Matthew Hammar Time: 1:38 PM Max, Min Temperature: 80, 60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/20/2023 4.000 12.57 53765.0 4277 3500.0 Type 2 Date: 09/22/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 7BD14591-7F44-4B9B-B528-FB35C1D58A45 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB09222023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Project Name: U-Haul Moving and Storage Test Location: Interior subfloor 2nd story Client: Bateman-Hall Admixtures: MS AC 534, DELVO, MP 322, SUPERPLASTISIZER Contractor: Bryan Landon Construction Supplier: Walters Ready Mix, Inc Mix Number: 142I 4000 Date: 8/25/2023 Cylinder Log #: 499 Set #: 1 Entrained Air (%): 2.5 Concrete Temperature (°F): 70 Ambient Temperature (°F): 53 Unit Weight (PCF): 144.8 Tested By: Leland Steiner Date: 8/25/2023 Field Test Results: Picked Up By: L. Steiner Pick Up Date: 8/26/2023 Pick Up Time: 1:20 PM Max, Min Temperature: 76,60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/1/2023 12.57 58270 4636 4000 Type 2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 7BD14591-7F44-4B9B-B528-FB35C1D58A45 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 9/22/2023 4.000 12.57 71300.0 5672 4000.0 Type 1 C 28 9/22/2023 4.000 12.57 72810.0 5792 4000.0 Type 3 D 28 9/22/2023 4.000 12.57 74910.0 5959 4000.0 Type 1 Second Break Average: 5808 Date: 09/25/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 576FBCAB-7D07-48AD-B6B8-DCF6253433FB 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB09222023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 50.0 Project Name: U-Haul Moving and Storage Test Location: 2nd level interior subfloor Client: Bateman-Hall Admixtures: MS AC 534, DELVO, MP 322, SUPERPLASTISIZER Contractor: Bryan Landon Construction Supplier: Walters Ready Mix, Inc Mix Number: 142I 4000 Date: 8/25/2023 Cylinder Log #: 500 Set #: 2 Entrained Air (%): 2.1 Concrete Temperature (°F): 73 Ambient Temperature (°F): 53 Unit Weight (PCF): 147.1 Tested By: Leland Steiner Date: 8/25/2023 Field Test Results: Picked Up By: L. Steiner Pick Up Date: 8/26/2023 Pick Up Time: 1:30 PM Max, Min Temperature: 80,60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/1/2023 12.57 58845 4681 4000 Type 3 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 576FBCAB-7D07-48AD-B6B8-DCF6253433FB 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 9/22/2023 4.000 12.57 75215.0 5984 4000.0 Type 1 C 28 9/22/2023 4.000 12.57 71745.0 5708 4000.0 Type 6 D 28 9/22/2023 4.000 12.57 74740.0 5946 4000.0 Type 3 Second Break Average: 5879 Date: 09/25/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 516CF514-DEA0-4870-9E61-4B0EC99E0183 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB09222023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 110.0 Project Name: U-Haul Moving and Storage Test Location: 2 level interior subfloor Client: Bateman-Hall Admixtures: MS AC 534, DELVO, MP 322, SUPERPLASTISIZER Contractor: Bryan Landon Construction Supplier: Walters Ready Mix, Inc Mix Number: 142I 4000 Date: 8/25/2023 Cylinder Log #: 501 Set #: 3 Entrained Air (%): 1.7 Concrete Temperature (°F): 69 Ambient Temperature (°F): 50 Unit Weight (PCF): 147.4 Tested By: Leland Steiner Date: 8/25/2023 Field Test Results: Picked Up By: L. Steiner Pick Up Date: 8/26/2023 Pick Up Time: 1:53 PM Max, Min Temperature: 80,60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/1/2023 12.57 64890 5162 4000 Type 1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 516CF514-DEA0-4870-9E61-4B0EC99E0183 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 9/22/2023 4.000 12.57 74755.0 5947 4000.0 Type 1 C 28 9/22/2023 4.000 12.57 73700.0 5863 4000.0 Type 6 D 28 9/22/2023 4.000 12.57 73660.0 5860 4000.0 Type 3 Second Break Average: 5890 Date: 09/25/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 993C7787-2DC6-429F-B2CD-97AFED24FB82 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File Name: 22247C09252023BF Compressive Strength of Concrete Test Specimens Date: 09/25/2023 Project Number: 22-247 Project Name: U-Haul Moving and Storage Client: Bateman-Hall Time on Project: 3 hours. Start Time: 10:15 AM Contractor: Bryant Greene Construction Supplier: Knife River Mix Number: C416426 Concrete Member: Site Elements Required 28 day Strength (psi): 3500.0 Admixtures: No Entrained Air Spec. (%): 6 +- 1.5 Slump Spec. (inches): 8 Max Results Testing: Set #:Cumulative Test Load Amount: Ticket #: Time Tested: Test Location:Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Slump (in): 1 10.0 22416739 11:40 AM Curb west side of project next to road 60 34.900 140.2 70 6 2.25 Field Technician Information Truck: STARLORD Total Trip Mileage: 22.00 Tested By: Bryton Ferguson Signature: Items observed are in general conformance with approved project documents and jurisdictional requirements. Items observed are NOT in general conformance with approved project documents and jurisdictional requirements. PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 993C7787-2DC6-429F-B2CD-97AFED24FB82 2 (Explanation to be given in Observations and/or Remarks.) Observations and/or Remarks: I arrived ont site and located where the concrete placement was to take place. I set up my gear and waited for concrete to arrive. When the concrete truck arrived I was able to obtain a sample and perform a concrete field test. I reported my results to the contractor and made strength specimens. I then cleaned my equipment and observed the duration of the pour. Reviewed By: Luke Hammar Signature: Inspection Images: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 993C7787-2DC6-429F-B2CD-97AFED24FB82 3 Testing: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 993C7787-2DC6-429F-B2CD-97AFED24FB82 4 Ticket Image: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A31A0C1D-6476-401E-9BCF-E80C2828B499 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File Name: 22247C09262023BF Compressive Strength of Concrete Test Specimens Date: 09/26/2023 Project Number: 22-247 Project Name: U-Haul Moving and Storage Client: Bateman-Hall Time on Project: 6.5 hours Start Time: 09:31 AM Contractor: Bryan Landon Construction Supplier: Walter's Ready Mix Mix Number: 1421 4000 Concrete Member: Interior Slab Required 28 day Strength (psi): 4000.0 Admixtures: MS AC 534, Delvo, MP 322 Entrained Air Spec. (%): N/A Slump Spec. (inches): 6 Max Results Testing: Set #:Cumulative Test Load Amount: Ticket #: Time Tested: Test Location:Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Slump (in): 1 10.0 08493 05:10 AM 3rd floor west side 45 36.600 147.0 65 1.25 6 2 60.0 08498 05:40 AM 3rd floor west side 45 36.200 145.4 61 1.5 6 3 110.0 08503 06:20 AM 3rd floor west side 45 36.500 146.6 60 1.5 5.75 Field Technician Information Truck: STARLORD Total Trip Mileage: 22.00 Tested By: Bryton Ferguson Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A31A0C1D-6476-401E-9BCF-E80C2828B499 2 Items observed are in general conformance with approved project documents and jurisdictional requirements. Items observed are NOT in general conformance with approved project documents and jurisdictional requirements. (Explanation to be given in Observations and/or Remarks.) Observations and/or Remarks: I arrived on site and located where the pour was to take place. I set up my gear and awaited for the concrete to arrive. Upon arrival I sampled from the first truck and performed a concrete field test. I reported my results to the contractor and made strength specimens. I repeated this process 2 more time every 50 yards of concrete placed. Upon completion I cleaned my gear and observed the duration of the pour. Reviewed By: Luke Hammar Signature: Inspection Images: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A31A0C1D-6476-401E-9BCF-E80C2828B499 3 Testing: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A31A0C1D-6476-401E-9BCF-E80C2828B499 4 Ticket Image: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A31A0C1D-6476-401E-9BCF-E80C2828B499 5 Ticket Image: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A31A0C1D-6476-401E-9BCF-E80C2828B499 6 Ticket Image: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 66ce3319-ae45-4619-8ac5-519e21a6134d 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File Name: 22247C09262023BF 2 Compressive Strength of Concrete Test Specimens Date: 09/26/2023 Project Number: 22-247 Project Name: U-Haul Moving and Storage Client: Bateman-Hall Time on Project: 2 hours Start Time: 09:30 AM Contractor: Bryant Green Construction Supplier: Knife River Mix Number: C401G456 Concrete Member: Site Elements Required 28 day Strength (psi): 3500.0 Admixtures: AE200, POLY980 Entrained Air Spec. (%): 6 +- 1.5 Slump Spec. (inches): 8 Max Results Testing: Set #:Cumulative Test Load Amount: Ticket #: Time Tested: Test Location:Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Slump (in): 4 10.0 22416805 10:15 AM Curb along south side of project 50 35.600 143.0 60 4.5 2 1/2 Field Technician Information Truck: STARLORD Total Trip Mileage: 0.00 Tested By: Bryton Ferguson Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 66ce3319-ae45-4619-8ac5-519e21a6134d 2 Items observed are in general conformance with approved project documents and jurisdictional requirements. Items observed are NOT in general conformance with approved project documents and jurisdictional requirements. (Explanation to be given in Observations and/or Remarks.) Observations and/or Remarks: I arrived on site for another pour earlier in the morning. Once that pour was completed I located where the curb pour was to take place and I set up my gear. I tested the first truck that arrived on site and I reported my results to the contractor. I then made strength specimens and cleaned my gear. I observed the duration of the concrete placement. Reviewed By: Luke Hammar Signature: Inspection Images: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 66ce3319-ae45-4619-8ac5-519e21a6134d 3 Testing: Ticket Image: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 8532ED54-B699-4388-82E6-0130DFDBDF34 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB10022023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10 Project Name: U-Haul Moving and Storage Test Location: Curb west side of project next to road Client: Bateman-Hall Admixtures: N/A Ticket Number: 22416739 Contractor: Bryant Greene Construction Supplier: Knife River Mix Number: C416426 Date: 9/25/2023 Cylinder Log #: 596 Set #: 1 Entrained Air (%): 6.0 Concrete Temperature (°F): 70 Ambient Temperature (°F): 60 Unit Weight (PCF): 140.2 Tested By: Bryton Ferguson Time Tested: 04:37 PM Field Test Results: Pick Up Date: 9/26/2023 Picked Up By: Matthew Hammar Time: 4:55 PM Max, Min Temperature: 80,60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 10/2/2023 4.000 12.57 47,955.0 3815 3,500.0 Type 6 Date: 10/04/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. E730BB20-A1F5-416F-BCA9-AE0287698740 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB10032023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10 Project Name: U-Haul Moving and Storage Test Location: 1421 4000 Client: Bateman-Hall Admixtures: MS AC 534, Delvo, MP 322 Ticket Number: 8493 Contractor: Bryan Landon Construction Supplier: Walter's Ready Mix Mix Number: 1421 4000 Date: 9/26/2023 Cylinder Log #: 610 Set #: 1 Entrained Air (%): 1.2 Concrete Temperature (°F): 65 Ambient Temperature (°F): 45 Unit Weight (PCF): 147 Tested By: Bryton Ferguson Time Tested: 08:40 AM Field Test Results: Pick Up Date: 9/27/2023 Picked Up By: Matthew Hammar Time: 3:56 PM Max, Min Temperature: 80, 60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 10/3/2023 4.000 12.57 54,405.0 4328 4,000.0 Type 1 Date: 10/04/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F7A91FD5-46E5-4E30-B640-E7E785A19DDF 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB10032023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 110.0 Project Name: U-Haul Moving and Storage Test Location: 1421 4000 Client: Bateman-Hall Admixtures: MS AC 534, Delvo, MP 322 Ticket Number: 8503 Contractor: Bryan Landon Construction Supplier: Walter's Ready Mix Mix Number: 1421 4000 Date: 9/26/2023 Cylinder Log #: 612 Set #: 3 Entrained Air (%): 1.5 Concrete Temperature (°F): 60 Ambient Temperature (°F): 45 Unit Weight (PCF): 146.6 Tested By: Bryton Ferguson Time Tested: 08:57 AM Field Test Results: Pick Up Date: 9/27/2023 Picked Up By: Matthew Hammar Time: 4:34 PM Max, Min Temperature: 80, 60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 10/3/2023 4.000 12.57 55720.0 4433 4000.0 Type 3 Date: 10/05/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. B8999DA5-B2BB-46DC-A354-5639CB2E50E4 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB10032023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Project Name: U-Haul Moving and Storage Test Location: C401G456 Client: Bateman-Hall Admixtures: AE200, POLY980 Ticket Number: 22416805 Contractor: Bryant Green Construction Supplier: Knife River Mix Number: C401G456 Date: 9/26/2023 Cylinder Log #: 613 Set #: 4 Entrained Air (%): 4.5 Concrete Temperature (°F): 60 Ambient Temperature (°F): 50 Unit Weight (PCF): 143.0 Tested By: Bryton Ferguson Time Tested: 08:54 AM Field Test Results: Pick Up Date: 9/27/2023 Picked Up By: Matthew Hammar Time: 4:41 PM Max, Min Temperature: 80, 60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 10/3/2023 4.000 12.57 58450.0 4650 3500.0 Type 2 Date: 10/05/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. D4E826E3-E37A-4DC3-A88A-DA1A653EEAF6 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247FB10032023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 60.0 Project Name: U-Haul Moving and Storage Test Location: 1421 4000 Client: Bateman-Hall Admixtures: MS AC 534, Delvo, MP 322 Ticket Number: 8498 Contractor: Bryan Landon Construction Supplier: Walter's Ready Mix Mix Number: 1421 4000 Date: 9/26/2023 Cylinder Log #: 611 Set #: 2 Entrained Air (%): 1.5 Concrete Temperature (°F): 61 Ambient Temperature (°F): 45 Unit Weight (PCF): 145.4 Tested By: Bryton Ferguson Time Tested: 08:43 AM Field Test Results: Pick Up Date: 9/27/2023 Picked Up By: Matthew Hammar Time: 4:13 PM Max, Min Temperature: 80, 60 Compressive Strength Data Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 10/3/2023 4.000 12.57 54915.0 4369 4000.0 Type 6 Date: 10/05/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. B126E603-E9ED-4548-B702-6DA9367579E7 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB10112023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 110 Project Name: U-Haul Moving and Storage Test Location: Gridlines 26-B page S2 of plans Client: Bateman-Hall Admixtures: MS AC 534, DELVO, MP 322, SUPERPLASTISIZER Contractor: Bryan Landon Construction Supplier: Walters Mix Number: 1421 4000 Date: 9/13/2023 Cylinder Log #: 556 Set #: 3 Entrained Air (%): 2.0 Concrete Temperature (°F): 70 Ambient Temperature (°F): 70 Unit Weight (PCF): 146.6 Tested By: Bryton Ferguson Date: 9/13/2023 Field Test Results: Picked Up By: Matthew Hammar Pick Up Date: 9/14/2023 Pick Up Time: 1:38 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/20/2023 12.57 53765 4277 3500 Type 2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. B126E603-E9ED-4548-B702-6DA9367579E7 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/11/2023 4.000 12.57 64,415.0 5125 3,500.0 Type 3 C 28 10/11/2023 4.000 12.57 66,455.0 5287 3,500.0 Type 1 D 28 10/11/2023 4.000 12.57 68,240.0 5429 3,500.0 Type 1 Second Break Average: 5280 Date: 10/13/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 54E76831-B014-488D-9695-EF4526F98ED6 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB10112023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 70 Project Name: U-Haul Moving and Storage Test Location: Gridlines 24-D page S2 of plans Client: Bateman-Hall Admixtures: MS AC 534, DELVO, MP 322, SUPERPLASTISIZER Contractor: Bryan Landon Construction Supplier: Walters Mix Number: 1421 4000 Date: 9/13/2023 Cylinder Log #: 555 Set #: 2 Entrained Air (%): 1.5 Concrete Temperature (°F): 70 Ambient Temperature (°F): 68 Unit Weight (PCF): 145.9 Tested By: Bryton Ferguson Date: 9/13/2023 Field Test Results: Picked Up By: Matthew Hammar Pick Up Date: 9/14/2023 Pick Up Time: 1:30 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/20/2023 12.57 54845 4363 3500 Type 1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 54E76831-B014-488D-9695-EF4526F98ED6 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/11/2023 4.000 12.57 70,830.0 5635 3,500.0 Type 1 C 28 10/11/2023 4.000 12.57 71,270.0 5670 3,500.0 Type 3 D 28 10/11/2023 4.000 12.57 69,770.0 5551 3,500.0 Type 1 Second Break Average: 5619 Date: 10/13/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 25E37C65-AC6D-4B3B-8FF3-9D215A2D95BD 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB10112023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Project Name: U-Haul Moving and Storage Test Location: Gridlines 27-E page S2 of plans Client: Bateman-Hall Admixtures: MS AC 534, DELVO, MP 322, SUPERPLASTISIZER Contractor: Bryan Landon Construction Supplier: Walters Mix Number: 1421 4000 Date: 9/13/2023 Cylinder Log #: 554 Set #: 1 Entrained Air (%): 1.2 Concrete Temperature (°F): 70 Ambient Temperature (°F): 68 Unit Weight (PCF): 145.7 Tested By: Bryton Ferguson Date: 9/13/2023 Field Test Results: Picked Up By: Matthew Hammar Pick Up Date: 9/14/2023 Pick Up Time: 1:01 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/20/2023 12.57 49275 3920 3500 Type 6 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 25E37C65-AC6D-4B3B-8FF3-9D215A2D95BD 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/11/2023 4.000 12.57 62,730.0 4990 3,500.0 Type 3 C 28 10/11/2023 4.000 12.57 68,030.0 5412 3,500.0 Type 1 D 28 10/11/2023 4.000 12.57 65,485.0 5210 3,500.0 Type 3 Second Break Average: 5204 Date: 10/13/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. D854923C-3ABF-480E-B47D-AF0ED8B784F1 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB10092023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 60 Project Name: U-Haul Moving and Storage Test Location: Second floor interior slab Client: Bateman-Hall Admixtures: N/A Contractor: Bryan Landon Construction Supplier: Walters Mix Number: 1421 4000 Date: 9/11/2023 Cylinder Log #: 543 Set #: 2 Entrained Air (%): 2.0 Concrete Temperature (°F): 70 Ambient Temperature (°F): 69 Unit Weight (PCF): 146.8 Tested By: Bryton Ferguson Date: 9/11/2023 Field Test Results: Picked Up By: Matthew Hammar Pick Up Date: 9/12/2023 Pick Up Time: 2:19 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/18/2023 12.57 64645 5143 4,000.00 Type 3 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. D854923C-3ABF-480E-B47D-AF0ED8B784F1 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/9/2023 4.000 12.57 79,755.0 6345 4,000.0 Type 1 C 28 10/9/2023 4.000 12.57 76,415.0 6079 4,000.0 Type 1 D 28 10/9/2023 4.000 12.57 78,375.0 6235 4,000.0 Type 3 Second Break Average: 6220 Date: 10/13/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 5067D2E1-DADB-4F09-A91A-AD0C89310E9D 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB10092023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10 Project Name: U-Haul Moving and Storage Test Location: Second floor interior slab Client: Bateman-Hall Admixtures: N/A Contractor: Bryan Landon Construction Supplier: Walters Mix Number: 1421 4000 Date: 9/11/2023 Cylinder Log #: 542 Set #: 1 Entrained Air (%): 1.5 Concrete Temperature (°F): 72 Ambient Temperature (°F): 69 Unit Weight (PCF): 147.2 Tested By: Bryton Ferguson Date: 9/11/2023 Field Test Results: Picked Up By: Matthew Hammar Pick Up Date: 9/12/2023 Pick Up Time: 2:08 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/18/2023 12.57 63845 5079 4,000.00 Type 6 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 5067D2E1-DADB-4F09-A91A-AD0C89310E9D 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/9/2023 4.000 12.57 77,360.0 6154 4,000.0 Type 3 C 28 10/9/2023 4.000 12.57 72,400.0 5760 4,000.0 Type 1 D 28 10/9/2023 4.000 12.57 73,455.0 5844 4,000.0 Type 2 Second Break Average: 5919 Date: 10/13/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. E321AF90-664C-4377-BDBA-87D36FBBF54B 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB10092023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 110 Project Name: U-Haul Moving and Storage Test Location: Second floor interior slab Client: Bateman-Hall Admixtures: N/A Contractor: Bryan Landon Construction Supplier: Walters Mix Number: 1421 4000 Date: 9/11/2023 Cylinder Log #: 544 Set #: 3 Entrained Air (%): 2.0 Concrete Temperature (°F): 71 Ambient Temperature (°F): 69 Unit Weight (PCF): 145.5 Tested By: Bryton Ferguson Date: 9/11/2023 Field Test Results: Picked Up By: Matthew Hammar Pick Up Date: 9/12/2023 Pick Up Time: 2:29 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/18/2023 12.57 64440 5126 4,000.00 Type 3 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. E321AF90-664C-4377-BDBA-87D36FBBF54B 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/9/2023 4.000 12.57 76,370.0 6076 4,000.0 Type 3 C 28 10/9/2023 4.000 12.57 76,325.0 6072 4,000.0 Type 1 D 28 10/9/2023 4.000 12.57 75,720.0 6024 4,000.0 Type 1 Second Break Average: 6057 Date: 10/13/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. EB8E6276-0330-4F5F-A8B6-69CCAF4F482C 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB10162023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Project Name: U-Haul Moving and Storage Test Location: West side sidewalk Client: Bateman-Hall Admixtures: AE200, POLY980 Contractor: BRYANT GREENE CONSTRUCTION INC. Supplier: KNIFE RIVER Mix Number: C401G456 Date: 9/18/2023 Cylinder Log #: 575 Set #: 1 Entrained Air (%): 7.0 Concrete Temperature (°F): 68 Ambient Temperature (°F): 62 Unit Weight (PCF): 137.3 Tested By: Matthew Hammar Date: 9/18/2023 Field Test Results: Picked Up By: Matthew Hammar Pick Up Date: 9/19/2023 Pick Up Time: 1:16 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/25/2023 12.57 38140 3034 4000 Type 6 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. EB8E6276-0330-4F5F-A8B6-69CCAF4F482C 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/16/2023 4.000 12.57 49,770.0 3959 4,000.0 Type 3 C 28 10/16/2023 4.000 12.57 50,580.0 4024 4,000.0 Type 1 D 28 10/16/2023 4.000 12.57 50,785.0 4040 4,000.0 Type 2 E 28 10/16/2023 4.000 12.57 51,205.0 4074 4,000.0 Type 3 Second Break Average: 4024 Date: 10/18/2023 Reviewed By: E. Vail Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A13D6BCB-0A23-4805-8FD0-A5728972DE8D 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB10232023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10 Project Name: U-Haul Moving and Storage Test Location: Curb west side of project next to road Client: Bateman-Hall Admixtures: N/A Contractor: Bryant Greene Construction Supplier: Knife River Mix Number: C416426 Date: 9/25/2023 Cylinder Log #: 596 Set #: 1 Entrained Air (%): 6.0 Concrete Temperature (°F): 70 Ambient Temperature (°F): 60 Unit Weight (PCF): 140.2 Tested By: Bryton Ferguson Date: 9/25/2023 Field Test Results: Picked Up By: Matthew Hammar Pick Up Date: 9/26/2023 Pick Up Time: 4:55 PM Max, Min Temperature: 80,60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 10/2/2023 12.57 47955 3815 3500 Type 6 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A13D6BCB-0A23-4805-8FD0-A5728972DE8D 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/23/2023 4.000 12.57 58,560.0 4659 3,500.0 Type 1 C 28 10/23/2023 4.000 12.57 61,675.0 4907 3,500.0 Type 1 D 28 10/23/2023 4.000 12.57 57,940.0 4609 3,500.0 Type 2 Second Break Average: 4725 Date: 10/24/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 57956AAA-192D-47F2-97E3-E51C706C7745 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB10242023EV Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Project Name: U-Haul Moving and Storage Test Location: C401G456 Client: Bateman-Hall Admixtures: AE200, POLY980 Contractor: Bryant Green Construction Supplier: Knife River Mix Number: C401G456 Date: 9/26/2023 Cylinder Log #: 613 Set #: 4 Entrained Air (%): 4.5 Concrete Temperature (°F): 60 Ambient Temperature (°F): 50 Unit Weight (PCF): 143.0 Tested By: Bryton Ferguson Date: 9/26/2023 Field Test Results: Picked Up By: Matthew Hammar Pick Up Date: 9/27/2023 Pick Up Time: 4:41 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 10/3/2023 12.57 58450 4650 3500 Type 2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 57956AAA-192D-47F2-97E3-E51C706C7745 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/24/2023 4.000 12.57 73,960.0 5884 3,500.0 Type 2 C 28 10/24/2023 4.000 12.57 74,875.0 5957 3,500.0 Type 1 D 28 10/24/2023 4.000 12.57 74,700.0 5943 3,500.0 Type 1 Second Break Average: 5928 Date: 10/27/2023 Reviewed By: E. Vail Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 0D76AE86-5A98-45CD-BFC2-F1F8C6187671 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB10242023EV3 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Project Name: U-Haul Moving and Storage Test Location: 1421 4000 Client: Bateman-Hall Admixtures: MS AC 534, Delvo, MP 322 Contractor: Bryan Landon Construction Supplier: Walter's Ready Mix Mix Number: 1421 4000 Date: 9/26/2023 Cylinder Log #: 610 Set #: 1 Entrained Air (%): 1.2 Concrete Temperature (°F): 65 Ambient Temperature (°F): 45 Unit Weight (PCF): 147.0 Tested By: Bryton Ferguson Date: 9/26/2023 Field Test Results: Picked Up By: Matthew Hammar Pick Up Date: 9/27/2023 Pick Up Time: 3:56 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 10/3/2023 12.57 54405 4328 4000 Type 1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 0D76AE86-5A98-45CD-BFC2-F1F8C6187671 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/24/2023 4.000 12.57 72,845.0 5795 4,000.0 Type 2 C 28 10/24/2023 4.000 12.57 69,120.0 5499 4,000.0 Type 1 D 28 10/24/2023 4.000 12.57 71,425.0 5682 4,000.0 Type 2 Second Break Average: 5658 Date: 10/27/2023 Reviewed By: E. Vail Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 083D0950-9430-469A-8D8D-D213A9037173 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB10242023EV4 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 60.0 Project Name: U-Haul Moving and Storage Test Location: 1421 4000 Client: Bateman-Hall Admixtures: MS AC 534, Delvo, MP 322 Contractor: Bryan Landon Construction Supplier: Walter's Ready Mix Mix Number: 1421 4000 Date: 9/26/2023 Cylinder Log #: 611 Set #: 2 Entrained Air (%): 1.5 Concrete Temperature (°F): 61 Ambient Temperature (°F): 45 Unit Weight (PCF): 145.4 Tested By: Bryton Ferguson Date: 9/26/2023 Field Test Results: Picked Up By: Matthew Hammar Pick Up Date: 9/27/2023 Pick Up Time: 4:13 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 10/3/2023 12.57 54915 4369 4000 Type 6 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 083D0950-9430-469A-8D8D-D213A9037173 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/24/2023 4.000 12.57 74,460.0 5924 4,000.0 Type 6 C 28 10/24/2023 4.000 12.57 70,770.0 5630 4,000.0 Type 1 D 28 10/24/2023 4.000 12.57 69,930.0 5563 4,000.0 Type 2 Second Break Average: 5704 Date: 10/27/2023 Reviewed By: E. Vail Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 141B8CFC-ADC5-4514-9497-5A1BA153BDAA 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 22247SB12042023MDH Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 9.0 Project Name: U-Haul Moving and Storage Test Location: North facing exterior slab on the middle garage entrance of U-Haul Client: Bateman-Hall Admixtures: AC534 Contractor: BRYANT GREENE CONSTRUCTION Supplier: KNIFE RIVER Mix Number: C401G456 Date: 11/3/2023 Cylinder Log #: 694 Set #: 1 Entrained Air (%): 5.5 Concrete Temperature (°F): 68 Ambient Temperature (°F): 43 Unit Weight (PCF): 139.0 Tested By: Matthew Hammar Date: 11/3/2023 Field Test Results: Picked Up By: C Hammar Pick Up Date: 11/4/2023 Pick Up Time: 5:00 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 11/10/2023 12.57 34990 2784 4,000.00 Type 3 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 141B8CFC-ADC5-4514-9497-5A1BA153BDAA 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 12/1/2023 4.000 12.57 48,135.0 3829 4,000.0 Type 2 C 28 12/1/2023 4.000 12.57 49,960.0 3975 4,000.0 Type 3 Second Break Average: 3902 Date: 12/04/2023 Reviewed By: Luke Hammar Signature: