Loading...
HomeMy WebLinkAboutINFRASTRUCTURE - 23-00368 - Summerfield Phases 11-13 - PlatVICINITY MAP SUMMERFIELD SUBDIVISION DIVISION NO.11112113 1 EAST OF THE BO�SE MERIDIAN CITY REXBURG, MADISON COUNTY, IDAHO INDEX SHEET SHEET INDEX SHEET NO. SHEET DESCRIPTION 1 INDEX SHEET 2 UTILITY MASTER P LAN 3 2400 WEST/370 SOUTH ROAD CONSTRUCTION 4 2355 WEST/460 SOUTH ROAD CONSTRUCTION 5 2325 2275 2100 WEST ROAD CONSTRUCTION 6 GRADING/ DRAINAGE PLAN OWNER/DEVELOPER KARTCHNER LAND MANAGEMENT INC. ATTN: CODY PUZEY 208-529-2116 CIVIL ENGINEER ALLIANCE CONSULTING ENGINEERS, INC. 150 EAST 200 NORTH SUITE P LOGAN, UTAH 84321 435-755-5121 THE FOLLOWING PLANS DETAIL THE CONSTRUCTION FOR ALL OF DIVISION 11-13 OF SUMMERFIELD. WHILE THE PLANS OUTLINE THE CONSTRUCTION OF THESE DIVISIONS TOGETHER THEY WILL BE CONSTRUCTED IN PHASES AS OUTLINED BELOW. CONTRACTOR TO INSTALL ADDITIONAL FIRE HYDRANTS AND TEMP TURN-AROUNDS (IF NECESSARY) WITH THE END OF EACH PHASE. DIVISION 11: Install MH2-MH7 (in 370 South), MH18 (in 2275 West) and sewer main (in 2100 West) with all laterals. Install all water main and laterals in 2100 West, 2275 West, and 370 South inside Div 11 boundary. Install all storm within Div 11 boundary (CB1 -CB8, SMH1 and all main lines). Curb and asphalt all roads within Div 11. DIVISION 12: Install all sewer in 2325 boundary. Install all storm within Div roads withing Div 12 boundary. West. Install all water within Div 12 12 boundary. Curb and asphalt all DIVISION 13: Finish remainder of project. GENERAL NOTES (APPLICABLE TO ALL CIVIL SHEETS): 1. ALL CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, AWWA STANDARDS, CITY OF REXBURG STANDARDS, ISPWC 2020, STATE OF IDAHO AND ANY OTHER APPLICABLE STANDARDS ISSUED BY THE CONTROLLING AGENCY. 2. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS BEFORE CONSTRUCTION. ANY DISCREPANCIES BETWEEN CONSTRUCTION DOCUMENTS AND FIELD CONDITIONS SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE OWNER. 3. CONTRACTOR SHALL REPAIR AND/OR REPLACE ANY AREAS AND/OR MATERIALS DAMAGED DURING CONSTRUCTION. 4. CONTRACTOR SHALL MAINTAIN ALL ADJACENT PROPERTY (PUBLIC & PRIVATE) FROM ALL CONSTRUCTION DEBRIS. 5. CONTRACTOR SHALL PROVIDE SMOOTH TRANSITION FROM ALL NEW CONSTRUCTION TO EXISTING CONDITIONS. 6. CONTRACTOR SHALL PROVIDE ALL NECESSARY AUTOMOBILE AND PEDESTRIAN TRAFFIC CONTROL DEVICES REQUIRED BY LOCAL, STATE, AND FEDERAL CODES AND ORDINANCES. 7. CONTRACTOR SHALL REPLACE SURVEY MONUMENTS DAMAGED DURING CONSTRUCTION. SURVEY MONUMENTS TO BE REPLACED BY A REGISTERED, LICENSED LAND SURVEYOR. 8. DIMENSIONS SHOWN ARE TO THE CENTER OF THE PIPELINE UNLESS OTHERWISE NOTED. 9. DISTANCES SHOWN ALONG PIPELINES ARE HORIZONTAL DISTANCES AND NOT ACTUAL PIPE LENGTHS. MORE PIPE MAY BE REQUIRED TO COMPLETE CONSTRUCTION THAN IS DIMENSIONED IN THE PLANS. 10. THRUST BLOCKS SHALL BE PLACED ON WATERLINES AT ALL DIRECTION CHANGES, FITTINGS, BENDS, ELBOWS, FIRE HYDRANTS AND GATES VALVES AS SHOWN IN THE PROJECT PLANS. 11. ALL CONCRETE REQUIRED ON THIS PROJECT SHALL BE 4000 PSF (28 DAY) CONCRETE. 12. CONTRACTOR IS RESPONSIBLE FOR PROVIDING WATER NECESSARY FOR DUST ABATEMENTK, COMPACTION, ETC. 13. THE CONTRACTOR SHALL BE RESONSIBLE FOR SECURING SOURCES FOR GRANULAR MATERIALS, WATER, WASTE SITES, AND ANY OTHER MATERIALS SOURCES AS REQUIRED FOR PROJECT COMPLETION. 14. ANY WORK DONE WITHIN A PUBLIC RIGHT-OF-WAY SHALL BE COORDINATED WITH THE APPROPRIATE TRANSPORTATION AGENCY AND SHALL MEET THE REQUIREMENTS OF THAT AGENCY AND THE REQUIREMENTS OF ANY RIGHT-OF-WAY OR SPECIAL USE PERMITS. 15. THE CONTRACTOR SHALL COORDINATE ALL LIVE TAPS AND ANY OTHER WORK OR MANIPULATION OF THE EXISTING WATER SYSTEM WITH THE ENGINEER AND THE WATER SYSTEM OWNER/CITY. 16. ON SLOPING AREAS THE CONTRACTOR SHALL TAKE PRECAUTIONS TO MITIGATE ANY POSSIBLE EROSION PROBLEMS IN THE TRENCHES DUE TO STORM WATER THAT MIGHT OCCUR DURING OR AFTER CONSTRUCTION AS DIRECTED OR APPROVED BY ENGINEER. 17. THE CONTRACTOR SHALL INSTALL AND MAINTAIN ALL EROSION CONTROL MEASURES AS DETAILED IN THE PROJECT PLANS UNTILL FINAL ACCEPTANCE OF THIS PROJECT. 18. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONS NECESSARY TO INSURE THAT NO STORM WATER/SEDIMENT AND/OR CONSTRUCTION DEBRIS ARE RELEASED FROM THE SITE. ANY RELEASES SHALL BE CLEANED AND MITIGATED AT THE CONTRACTOR'S EXPENSE. 19. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACCESS AND RELATED TRAFFIC CONTROL WITH THE COUNTY, CITY, AND STATE ROADWAY DEPARTMENTS. THE ENGINEER SHALL REVIEW ALL TRAFFIC CONTROL PLANS. 20. ALL GATE VALVES SHALL BE LOCATED NEAR TO TEES OR CROSSES AND THEIR ASSOCIATED REDUCERS AS SHOWN ON THE PROJECT PLANS. 21. CONTRACTOR SHALL PROVIDE ALL NECESSARY FITTINGS, HARDWARE, LABOR, ETC. TO CONSTRUCT VERTICAL AND HORIZONTAL BENDS IN PIPE AS NEEDED TO MEET THE REQUIRED GRADES, ALIGNMENTS AND COVER REQUIREMENTS. 22. ALL AIR RELEASE VALVES SHALL BE INSTALLED AT THE CREST OF THE VERTICAL CURVATURE OF THE WATER LINE. CONTRACTOR SHALL RECORD ACTUAL LOCATION OF VALVES ON FIELD RECORD DRAWINGS. 23. THE CONTRACTOR SHALL COORDINATE WITH THE CITY OF REXBURG AND WITH THE ENGINEER FOR ALL UTILITY INSPECTIONS PRIOR TO BACKFILLING. 24. THE CONTRACTOR SHALL COORDINATE ALL INSPECTIONS WITH THE ENGINEER. AT A MINIMUM, THE ENGINEER SHALL BE NOTIFIED TO INSPECT: 1)SEWER PRIOR TO BACKFILLING, 2)WATER PRIOR TO BACKFILLING, 3)STORM SEWER PRIOR TO BACKFILLING, 4)CURB & GUTTER AND FORMS PRIOR TO POURING, 5)ROADWAY GRADES PRIOR TO PAVING, 6)ASPHALT DURING PAVING. 25. ALL WATER SYSTEM COMPONENTS SHALL BE INSTALLED, PRESSURE TESTED, AND CHLORINATED PRIOR TO COMPLETING ANY ROADWAY CONSTRUCTION PER AWWA STANDARD 651. 26. CHLORINATION SHALL BE DONE BY CONTRACTOR AT THE CONTRACTORS EXPENSE. CONTRACTOR TO DISPOSE OF CHLORINATED SOLUTION ACCORDING TO AWWA STANDARD C651. 27. ALL SEWER SYSTEM COMPONENTS SHALL BE INSTALLED AND VIDEO INSPECTIONS DONE AND APPROVED PRIOR TO ASPHALTING. IF NECESSARY, THE CONTRACTOR SHALL PAY FOR THIS EXPENSE AS IT IS CONSIDERED INCIDENTAL TO SEWER CONSTRUCTION. DIG LINE 1-800-342-1585 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKER OF THE UNDERGROUND MEMBER UTILITIES. IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION I.S.P.W.C. 2020 CONSTRUCTION ON THIS PROJECT SHALL CONFORM TO THE I.S.P.W.C. STANDARDS AND CITY OF REXBURG STANDARDS \ONAL £Nc \ T 1 9 4 3-2� \MA C K E z 0 W CC N z o I � Q W J U U W 0 ry n r i i ti q �w CL w n � N I oLi � LC) 0 0 N Z Ln ro LnQo� W J O SHEET 1 OF 6 SHEETS SUMMERFIELD SUBDIVISION ICI VISION NO.1 � 1 � 13 EEG E N D > EXISTING WATER LINE -SIZE E 8 DI WATER yY- AS SHOWN NOTES: e-w EXISTING WATER LATERAL NEW ASPHALT UTILITY MASTERPLAN I � � PROPERTY BOUNDARY All sewer laterals to be installed at 5' below E 8 PVC SEWER EXISTING PVC SANITARY IF 8 DI WATER PROPOSED DI CLASS 50 EXISTING ASPHALT native ground 1 0' Into property. SEWER LINE AS NOTED WATER LINE AS NOTED PROPOSED 1" SERVICE PER e-s EXISTING SEWER LATERAL w •',,>.1;;:.:4;;•�.:' �;: :`.'.s::::y`1' r�: All hydrants t0 be Wate ro u s brand. ISPWC SD-401 PROPOSED CONCRETE PROPOSED PVC SDR35 SANITARY ...:..,a•: ��' j'' '' "'` 8 PVC SEWER} SEWER LINE AS NOTED 15 E ADS SD-- EXISTING STORM LINE/CB . >,,::;::::•,::,..�s;;:.::;�,•;:::f:�y..:•:- EXISTING CONCRETE S\ONAL FN PROPOSED 4 PVC SDR 35 SEWER 15 ADS SDWN NEW STORM LINE/CB 1°; r •' ''y" 0 30 60 120 LATERAL (S=2.0% min) EXISTING STREET LIGHT G EXISTING GAS NEW STREET LIGHT -PER SCALE: 1 "= 60' (24X36 PLAN SET) - EXISTING ELECTRICAL '* CITY STANDARDS 929 4 3-2�3 q qTf OF SOP P� CANAL MA C K E- e� Fy C►i w 25 24 YS 22 21 20 19 18 17 16 15 14 13 12 11 7,610 sf 6,596 sf 6,596 sf 6,596 sf 6,596 sf 6,596 sf 6,596 sf 7,695 s.f. 7,695 s.f. 7,695 s.f. 7,695 s.f. 7,695 s.f. 7,695 s.f. 7,704 s.f. 9,610 s.f. 10,414 s.f. S 8 7 8 5 4 S 2 1 0 o 11,098 s.f. D IV 13 D IV 1 11,713 s.f. 11,851 s.f. 11,852 s.f. 11,852 s.f. 11,852 s.f. 11,852 s.f. 11,852 s.f. 11,719 s.f. w S W S W S W S W S W S W S W S W S W S W 5 W S W S W S W S W ,. S W N z o --------- ------ ----- s w I I : s w s w s w s w s w s w s w s w � 8 DI TER D1 WAT R 8 DI W ERI D WATER DI WATER `8 DI WATER 8 DI WATER 8 DI W T _ Q : 8 DI WATER 8 PVC SEWE 8 PVC SEW 8 P WE 8 PVC SE E H2 8 PVC SEWE 8 PVC SEWE 8 PVC SEW 8 PVC S _ --- ADS SD 15 ADS SD 1 S SD I 370 SO TH STREET MH3 8Q SEWER- 15- PVC SEWE 8 p� WATER ---- ° �r{Jy,Sn(,[� j�j+'j+'�' m MH4 $ VC SE E� 8 DI VAN SO T TDf�VATER 8 DI WATER 8 DI WATER 8 DI WATER w 8 DI W TER 8 DI WATER r7, AD vc o12 ADS Spp 8 PVC S E 8 PVC SEWE 8 PVC S WE 8 PVC SEWE 8 PVC S E 8 PVC SEWE MH6 MH7 _us w s w s w s w s w 12 ADS sr� H 5 W 1$SW---=--- Q1110 3 14 6,736 s.f. S w ,7,623 s.f. 622 s.f. 6,735 s.f. ,+.•,.s7,623 s.f. o 10 S w E" 00 oo 00 S W s W S W S W W s w s w co 0 12,576 s.f. s "' w C- ly Q w 11 w n2 Q 1 1,849 s.f. 18 13 �I WATE 18 1� 8 15 1Y 0 10,926 s.f. 10,243 s.f. 10,0311 s.f. 10,038 s.f. 10,0581 s.f. 12,809 s.f. °° W 12 W� 7,910 s.f. 7,910 s.f. Q 7 064 s.f. = I ¢� 13,372 s.f. 11 7,910 s.f. _ = 7 023 s.f. e-s s 3 s s 3 S S oW oO 12,918 s.f. �w e-W W W W W wEi g DIV 11 N 0 j Uw _ �wO :. w ¢ � 11,953 s.f. o w • � E" 44;U 11 >C) •` 1S a 15 8 16 7,075 s.f. a S ;' M o� w 7,910 s.f. 7,910 s.f. 7,910 s.f. 7,075 s.f. � Q W W w •... a-s s s s s S 3 e-w w s w w s w W lop q �-+ co r' SUMMERFIELD DIVISION 9 / (�� E W I o Uj w 14 14 7 p I A e-S q z 7,910 s.f. U 7,910 s.f. 7 910 s.f. > 17 e_s /e- > a = e-s e-W w �W o a 7,075 s.f. rn 3 3 cn 3 v) 3 � 3 3 =r e-s cn s- s s s e-s a-w I I I I I I I I I I I e-W 0 W W w W e-w - GAS -GAS SAS r - N N N - GASLd q or F p•• ^� • 15 6,9 15 s.f. 6,9688 s.f. vwi s ATER WAT R TE - D 3 6,900 s.f. s s s �' e-S U ER W R ER • c e-W W W W a 18 I rn A S S DS SL' �..' �: ° a e- ..: w w 14151 s.f. ' e-W v ... 16 Qoo 16 5 p -... -...- -...- -...- . ..•.� 6,780 s.f. > 6,780 s.f. 6,780 s.f. � QI W ,~HE" e-s s S s w �, co La 3 I ¢ H e-w w w w W : e-s U +; w U) `. W w E, I e-w • w w w w * 0 Uj -10 6,780 s.f. w a� s--�� 6,780 s.f. 6,780 s.f. a I I e-s s s 18 0 e-w W"' 1 W 0 s 6,069 s.f. w I 18 18 a � w e-S e-s 6,780 s.f. s S 6,780 s.f. 6,780 s.f. s , ' I w �O e-w w w w w s 6,069 s.f. Ei 19 a °° 19 Y °° w F cK 6,780 s.f. 6,780 s.f. 3 W e-w e-S S S 3 21 % r-: IR -- a-s z. e-w w w w > �+ 6,069 s.f. -W 4 d� w p w w W S I ao w ¢ ¢ W w ' ��'_ w e-s �0 S � s 7,712 s.f. 7 71O s � 0 s.f. 771s.f. e-s e-w ' w°� W ' W 4 p e-w w co 6,069 s.f. o I } w o a w L - 12 D ; SD Ld 460 SOUTH ST ET 0 0 8 DI WATER 8 DI WATE 8 DI WAT R 8 DI TER 8 DI WATER I R R 68' �8 a-s : 8 PVC SEWE 8 PVC S E 8 PVC S E 11 SIDEWALK ADS SD 1 ADS SD M H 10 6,069 s.f. e-w �_ s A (( 7' 19.5' 19.5' 30" s w s w s w s w s w s w I � 5 2% ROLLED CURB 14 2% p; 8 8 10 11 12 13 7,444 s.f. w N 6,069 s.f. a-s a-s //\//\/ /\\ 12" GRANULAR BORROW 9,069 s.f. 6,435 s.f. 6,435 s.f. 6,435 s.f. 6,435 s.f. 6,435 s.f. s s e-w .t-Wco 00 w 2-1/2" ASPHALT PLANTMIX PAVEMENT 4» 3-1/2 OF AGGREGATE BASE 15 85 �, '. I USE 12" GRANULAR BORROW 12" 6,526 s.f. 6,065 s.f. s s e-s GEOTEXTILE FABRIC BELOW W W e-w I AND UP SIDES 2.5" I: SUMMERFIELD DIVISION 6 68' TYPICAL ROAD CROSS-SECTION ao o cn 3 (1)3 U) 3 U) 3 3 U) 3 I cn 3 cn 3 ! 30„ P/(A w 00 I I I I I I I I I s a� a) aD m a) �� a� ai a� m e-s ( . y 17 _-) CL U Ld O rY v' 00 O A 0 o z O J 0 r SHEET 2 OF 6 SHEETS MH1 LEGEND 4850 Tee w/ n (3) valves MH9—exist STA: 0-7.00 8.97 R Rim: 4848.964840 IE—in: 4835.90 IE—out: 4835.75 DATUM ELE 4835.00 LO Q0 0+00 1 +00 2+00 3+00 4+00 5+00 460 SOUTH STREET SUMMERFIELD SUBDIVISION DIVISION NO.11112113 L l'6-V8-V = A1­11 lAd 9-V79+9 = `d1S Ind 2355 WEST1460 SOUTH ROAD CONSTRUCTION 0 30 60 120 SCALE: 1 "= 60' (24X36 PLAN SET) SCALE: 1 "= 10'_VERTICAL c6 w 0 —N to ro (0�'t q- LO P2 0 0 :2NIiE w I b\ cD rl I - o in V) m � E CL Lm I tiL'058t = AN-11 Ind ZL'OL+Z = d1S Ind L8'6-V8-V = A3_13 lAd 8L'25+0 = ViS lAd o� 0 'L L O C' 6 I.. 00 J Ln r M Q_ O N , rn��a +00�t V) UJ U U) L A'Fi�Q� 9'8_178-17 8-V'6t8-V ZZ'6�8t Z�'6t8� Z9'6-V8-V _V'8t8-17 Z8'6-V8-V Z'8_178_17 Z0'OS8-17 9'8_178-17 zz'OSB-17 6'8-V8-V Z-17'099-17 I,'6-V8-V Z9'OS8_17 6'8t8-V 59'058-17 L'8_178_17 9-17'099-17 8'8_178-17 Sz'OS8t 8'8_178-17 50'058-17 6'8-V8-V -V8'6-V8-V -'8-178-17 9t'6-V8t S 8�817 Ld 00 Wo \ m � 3 > OJCpr,r, N p O N N 0 j 0,6000000 4 =0 I �w o —w U) (D 0 NOTES: All sewer laterals to be installed at 5' below native ground 10' into property. o All hydrants to be Waterous brand. + 0 0 + Ln 0 0 h w P, co W o 0 Lf) +cr) r')N 0 0 N 0 0 0 0 0 E 8 PVC SEWER e-s 8 PVC SEWER 4 PSEW S WV E 8 DI WATER 9VN y. e-w �- 8 DI WATER — PROPERTY BOUNDARY EXISTING PVC SANITARY SEWER LINE AS NOTED EXISTING SEWER LATERAL PROPOSED PVC SDR35 SANITARY SEWER LINE AS NOTED PROPOSED 4" PRESSURE SEWER PROPOSED 4" PVC SDR 35 SEWER LATERAL (S=2.0% min) EXISTING WATER LINE —SIZE AS SHOWN EXISTING WATER LATERAL PROPOSED DI CLASS 50 WATER LINE AS NOTED PROPOSED 1" SERVICE PER ISPWC SD-401 EXISTING STORM LINE/CB NEW STORM LINE/CB EXISTING STREET LIGHT NEW STREET LIGHT —PER CITY STANDARDS NEW ASPHALT EXISTING ASPHALT •"''''3''''' PROPOSED CONCRETE •:r ?:t::5: •.,.* :'? ...,..� ;::y,.;: ;? EXISTING CONCRETE w 15 E ADS SDW 15 ADS SD -o \ONAL E c 929 4 3-2� , \vq qTF OF SOP P� MACKE y CL W H V)C� n N L0 ry O �LLi 0 o o .� N z Lo ro con O W J O SHEET 4 OF 6 SHEETS NOTES: All sewer laterals to be installed at 5' below native ground 10' into property. All hydrants to be Waterous brand. 3 0 ~v I SZ' 158- = n3­13 Ind I ZO'9L+8 = 'd1S Ind E o LZ LZ'058ti = n3­13 Ind LZ'81+9 = `d1S Ind t9'098V = AA­11 Ind -VS'L-V+S = `d1S Ind 6Z'098ti = n1­13 Ind 88'9L+ti = d1S Ind 3 0 z � I 80' L58V = n3-13 Ind 3 o > ti-V' 19+Z = d1S Ind 0 L0 00 rr 0 0 N cq � r, � co + 00 0 r �-% •• n :2V)Ww 0 TF V) U Ll- LO 0 CO N O �0) L0�� Lc)o 0000000000 1:2_c (o �w o + -w n - cn 0 I I U) U n 00 -0 J V a' o � a •n l l' lS8t Z'6-V8t I•I,92 0' 6-V8t �6'OS8� tiL'OS8t �S'OS8� O'6�8t Z2'058ti Z9'OSB-17 S'6-V8t S�'OS8� Z�'OS8� ZS'OSB� S'6�8t ZL'058-V Z6'058V 20' L S8ti 0'6-V8-V 28'OSB-17 �9'OS8� ��'058ti l'6t8� �Z'OSB� O'6�8t 20'OS8-V 0 o 6'8�8-V o+ 00 wo N� A O 0 + 00 0 O O 0 + LO SX s W S.f. S W S.f. s W S.f. s W �I WATER O 0 O 0 N O 0 + S S.f. W - 8459 � t. s - W- 1f 14,151 1� 6,069 s W 21 6,069 s W 21 6,069 s -w 6,069 s W 23 6,069 S W 24 6,069 S W 25 6,065 S W 3 � e SUMMERFIELD SUBDIVISION DIVISION NO.11112113 23251227512100 WEST ROAD CONSTRUCTION 61 0 30 60 120 SCALE: 1 "= 60' (24X36 PLAN SET) SCALE: 1 "= 10'-VERTICAL 7+00 8+00 2275 WEST STREET Finish grade 8" Tee w/ //'--(3) valves 0 � r U L o + 0000 0 cfl 00 U II II N o Ex FH + � w r Q o, Finish 5;a m grade o_ a - Original ground III 0.40% - - - - Tie t 0 existing stub 5' min 8" DI waterline ,. MF 141 LF 8" PVC 3 =0.4% ST Rir IE- IE STA: 7+45.27 4.81 L existing manhole Rim: 4851.41 I E-i n: 4841.98 IE-out: 4841.78 r7 (0 N r O rN 00 oo pp as O rn O O O' O O O ci O 00 00 00 co 00 00 00 00 00 00 00 00 00 8+00 2100 WEST STREET 1,852 s.1 1� 13,372 s.f. 8" Tee w/ (3) valves 6 4'dia a: 8+88.19 8.84 L n: 4851.96 -in: 4842.74 -out: 4842.54 LEGEND PROPERTY BOUNDARY E s PVC SEWER EXISTING PVC SANITARY SEWER LINE AS NOTED e-s EXISTING SEWER LATERAL PROPOSED PVC SDR35 SANITARY s PVC SEWER SEWER LINE AS NOTED 4 PSEW PROPOSED 4" PRESSURE SEWER PROPOSED 4" PVC SDR 35 SEWER S LATERAL (S=2.0% min) WV EXISTING WATER LINE -SIZE E 8 DI WATER s� AS SHOWN e-W EXISTING WATER LATERAL PROPOSED DI CLASS 50 �- 8 DI WATER WATER LINE AS NOTED PROPOSED 1" SERVICE PER W ISPWC SD-401 15 E ADS SDW EXISTING STORM LINE/CB 15 ADS SD -o NEW STORM LINE/CB # EXISTING STREET LIGHT NEW STREET LIGHT -PER CITY STANDARDS NEW ASPHALT EXISTING ASPHALT PROPOSED CONCRETE EXISTING CONCRETE •:r ?:t::5: •.,.* ...f..� ;::y,.;: ;? :'? v/..�•,.i�ti!,;�i`i;c WERE, �1 8- N-400 10929 3-29 O�9TF OF \MA C K z 0 W N z o N Q I �Q W LU Q J Q U � co �� �-I P + O �o o C� O� � 0 �Pq q o W C\2 C\2 E cn Ld � W co r�j c J W I- V) rN � N 00 Lo I O L0 O O O .� N z Lf-) 0 J O SHEET 5 OF 6 SHEETS