HomeMy WebLinkAboutREVISED PLANS - 22-00385 - Tri-Steel - Commercial ShopRe
v
.
7/
1
2
/
2
0
2
2
1:
3
5
:
5
8
P
M
CO
V
E
R
Au
t
h
o
r
TR
I
S
T
E
E
L
RE
A
L
E
S
T
A
T
E
A1
0
1
TRISTEEL
REAL ESTATE, LLC
UP
12'x12' OHD
X-BRACE
X-BRACE
DE
S
I
G
N
E
D
F
O
R
5
-TO
N
CR
A
N
E
30
'
x
1
6
'
O
H
D
30
'
x
1
6
'
S
H
E
E
T
E
D
F
O
30
'
x
1
6
'
O
H
D
12' - 0"
15
'
-
0
"
30
'
-
0
"
15' - 0"
13
'
-
6
"
12' - 0"
10
0
'
-
0
"
-Special Inspections by
Connect Engineering
-Exit Lighting and Signs
will Comply with Section
1008 and 1013
-Doors will meet Section 1010
and will have panic hardware
Shop Space
F-1 Occupancy 306 Factory-Machinery/Metals
Type II-B Construction
24 person Occupancy 12,000/500=24 Table 1004.5
15,500 S.F. allowed area Table 506.2 (NS, Type II B)
No fire Sprinklers required under 12,000 s.f. 903.2.4
1 Male Water Closet & 1 Female Water Closet/100 location TBD 2902.1
Business Space
B Occupancy 304.1 Business Group
Type V-B Construction
33 person Occupancy (50 x 50 x 2)/150=33 Table 1004.5
9,000 S.F. allowed area Table 506.2 (NS, Type V-B)
2 Male Water Closets & 2 Female Water Closets
-1ea per 25. location TBD section 2902.1
Office
120' - 0"
2 hr fire partition wall
50' - 0"
50
'
-
0
"
90 min fire door
11
'
-
0
"
Office
OfficeStorage
DN
A1031
A104
A103
A104
1
2
2
A
B
C
D
4
32
1
H
8
6
5 7
F
G
E
2nd floor Future
Office Space
UP
12'x12' OHD
X-BRACE
X-BRACE
DE
S
I
G
N
E
D
F
O
R
5
-TO
N
CR
A
N
E
30
'
x
1
6
'
O
H
D
30
'
x
1
6
'
S
H
E
E
T
E
D
F
O
30
'
x
1
6
'
O
H
D
12' - 0"
15
'
-
0
"
30
'
-
0
"
15' - 0"
13
'
-
6
"
12' - 0"
10
0
'
-
0
"
-Special Inspections by
Connect Engineering
-Exit Lighting and Signs
will Comply with Section
1008 and 1013
-Doors will meet Section 1010
and will have panic hardware
Shop Space
F-1 Occupancy 306 Factory-Machinery/Metals
Type II-B Construction
24 person Occupancy 12,000/500=24 Table 1004.5
15,500 S.F. allowed area Table 506.2 (NS, Type II B)
No fire Sprinklers required under 12,000 s.f. 903.2.4
1 Male Water Closet & 1 Female Water Closet/100 location TBD 2902.1
Business Space
B Occupancy 304.1 Business Group
Type V-B Construction
33 person Occupancy (50 x 50 x 2)/150=33 Table 1004.5
9,000 S.F. allowed area Table 506.2 (NS, Type V-B)
2 Male Water Closets & 2 Female Water Closets
-1ea per 25. location TBD section 2902.1
Office
120' - 0"
2 hr fire partition wall
50' - 0"
50
'
-
0
"
90 min fire door
11
'
-
0
"
Office
OfficeStorage
Re
v
.
7/
1
2
/
2
0
2
2
1:
3
5
:
5
9
P
M
FL
O
O
R
P
L
A
N
Au
t
h
o
r
TR
I
S
T
E
E
L
RE
A
L
E
S
T
A
T
E
A1
0
2
1/16" = 1'-0"1 100
100
0' -0"
126
26' -0"
102
2' -0"
A B C D HF
120
20' -0"
CHARCOAL
POLAR WHITE
WHITE
BRONZE
112
12' -0"
100
0' -0"
126
26' -0"
102
2' -0"
ABCDH
29' - 6"
1 " / 1 '-0 "
120
20' -0"
G E
112
12' -0"
Re
v
.
7/
1
2
/
2
0
2
2
1:
3
5
:
5
9
P
M
EL
E
V
A
T
I
O
N
Au
t
h
o
r
TR
I
S
T
E
E
L
RE
A
L
E
S
T
A
T
E
A1
0
3
3/32" = 1'-0"2 North
3/32" = 1'-0"1 South
100
0' -0"
126
26' -0"
102
2' -0"
4 3 2 18657
120
20' -0"
112
12' -0"
100
0' -0"
126
26' -0"
102
2' -0"
4321 8657
120
20' -0"
112
12' -0"
Re
v
.
7/
1
2
/
2
0
2
2
1:
3
6
:
0
0
P
M
EL
E
V
A
T
I
O
N
Au
t
h
o
r
TR
I
S
T
E
E
L
RE
A
L
E
S
T
A
T
E
A1
0
4
1/16" = 1'-0"1 East
1/16" = 1'-0"2 West
UP
12'x12' OHD
X-BRACE
X-BRACE
30
'
x
1
6
'
O
H
D
30
'
x
1
6
'
S
H
E
E
T
E
D
F
O
30
'
x
1
6
'
O
H
D
6'-6"x7'-0" FO
3'-6"x7'-0" WD
(2) 1'-6"x7' LITES
16
'
-
0
"
12' - 0"
15
'
-
0
"
30
'
-
0
"
15' - 0"
13
'
-
6
"
11
'
-
6
"
12' - 0"7' - 4"
10
0
'
-
0
"
Entrance
95
'
-
8
"
72
'
-
4
"
628' - 4"
120' - 0"
50' - 0"
50
'
-
0
"
East Side Drive
5000 S
47
'
-
4
"
North
Driveway area
26
8
'
-
0
"
1258' - 4"
460' - 0"