Loading...
HomeMy WebLinkAboutREVISED DRAWINGS 8-5 - 22-00385 - Tri-Steel - Commercial ShopAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : Tri-Steel - Commercial Shop Address : 4977 Eastside Dr Application Type : Document Filename : REVISED PLANS - 22-00385 - Tri-Steel - Commercial Shop.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Pg 2 Free text Cody Jones : Building Open 2 Fire wall will need to extend 4' on each side. Door may need to be fire rated if within that distance. # 22-00385 Madison County - Commercial Report Date: 07.14.2022 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) Re v . 7/ 1 2 / 2 0 2 2 1: 3 5 : 5 8 P M CO V E R Au t h o r TR I S T E E L RE A L E S T A T E A1 0 1 TRISTEEL REAL ESTATE, LLC UP 12'x12' OHD X-BRACE X-BRACE DE S I G N E D F O R 5 -TO N CR A N E 30 ' x 1 6 ' O H D 30 ' x 1 6 ' S H E E T E D F O 30 ' x 1 6 ' O H D 12' - 0" 15 ' - 0 " 30 ' - 0 " 15' - 0" 13 ' - 6 " 12' - 0" 10 0 ' - 0 " -Special Inspections by Connect Engineering -Exit Lighting and Signs will Comply with Section 1008 and 1013 -Doors will meet Section 1010 and will have panic hardware Shop Space F-1 Occupancy 306 Factory-Machinery/Metals Type II-B Construction 24 person Occupancy 12,000/500=24 Table 1004.5 15,500 S.F. allowed area Table 506.2 (NS, Type II B) No fire Sprinklers required under 12,000 s.f. 903.2.4 1 Male Water Closet & 1 Female Water Closet/100 location TBD 2902.1 Business Space B Occupancy 304.1 Business Group Type V-B Construction 33 person Occupancy (50 x 50 x 2)/150=33 Table 1004.5 9,000 S.F. allowed area Table 506.2 (NS, Type V-B) 2 Male Water Closets & 2 Female Water Closets -1ea per 25. location TBD section 2902.1 Office 120' - 0" 2 hr fire partition wall 50' - 0" 50 ' - 0 " 90 min fire door 11 ' - 0 " Office OfficeStorage 2 hr fire partition wall extends 4' past intersection 4' - 2 " DN A1031 A104 A103 A104 1 2 2 A B C D 4 32 1 H 8 6 5 7 F G E 2nd floor Future Office Space 100 0' -0" 126 26' -0" 102 2' -0" A B C D HF 120 20' -0" CHARCOAL POLAR WHITE WHITE BRONZE 112 12' -0" 100 0' -0" 126 26' -0" 102 2' -0" ABCDH 29' - 6" 1 " / 1 '-0 " 120 20' -0" G E 112 12' -0" Re v . 7/ 1 2 / 2 0 2 2 1: 3 5 : 5 9 P M EL E V A T I O N Au t h o r TR I S T E E L RE A L E S T A T E A1 0 3 3/32" = 1'-0"2 North 3/32" = 1'-0"1 South 100 0' -0" 126 26' -0" 102 2' -0" 4 3 2 18657 120 20' -0" 112 12' -0" 100 0' -0" 126 26' -0" 102 2' -0" 4321 8657 120 20' -0" 112 12' -0" Re v . 7/ 1 2 / 2 0 2 2 1: 3 6 : 0 0 P M EL E V A T I O N Au t h o r TR I S T E E L RE A L E S T A T E A1 0 4 1/16" = 1'-0"1 East 1/16" = 1'-0"2 West UP 12'x12' OHD X-BRACE X-BRACE 30 ' x 1 6 ' O H D 30 ' x 1 6 ' S H E E T E D F O 30 ' x 1 6 ' O H D 6'-6"x7'-0" FO 3'-6"x7'-0" WD (2) 1'-6"x7' LITES 16 ' - 0 " 12' - 0" 15 ' - 0 " 30 ' - 0 " 15' - 0" 13 ' - 6 " 11 ' - 6 " 12' - 0"7' - 4" 10 0 ' - 0 " Entrance 95 ' - 8 " 72 ' - 4 " 628' - 4" 120' - 0" 50' - 0" 50 ' - 0 " East Side Drive 5000 S 47 ' - 4 " North Driveway area 26 8 ' - 0 " 1258' - 4" 460' - 0"