Loading...
HomeMy WebLinkAboutREDLINED DRAWINGS - 22-00385 - Tri-Steel - Commercial ShopAuthor Name Author Email Author Phone No.: Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : Tri-Steel - Commercial Shop Address : RP05N39E146621 Application Type : Document Filename : Drawings 6-1-22.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Pg 6 Free text Cody Jones : Building Open 6 Cross slope of sidewalks and landings at doors not to exceed 2% slope. One parking stall to be designated as ADA parking and will need to be van accessible. 1106.5 Panic hardware required on egress doors due to occupant load of building being over 50. Stairs risers 4"-7". Stair treads 11" min. Landings to be in compliance. Handrails on both sides of stairs and meet requirements of section1011. Pg 6 Free text Cody Jones : Building Open 6 fire rated door Pg 6 Free text Cody Jones : Building Open 6 Second level floor plan. Pg 6 Free text Cody Jones : Building Open 6 Fire wall will need to meet one of the exceptions in 706 or have four feet of protection on each side of fire wall. Pg 7 Callout Stan Crittenden : Fire Open 7 All fire department access roads need to be able to drivable year round and with stand a 75,000 lb weight limit. # 22-00385 Madison County - Commercial Report Date: 06.07.2022 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) Re v . 6/ 2 / 2 0 2 2 7: 1 0 : 5 8 A M CO V E R Au t h o r TR I S T E E L RE A L E S T A T E A1 0 1 TRISTEEL REAL ESTATE, LLC UP 12'x12' OHD X-BRACE X-BRACE DE S I G N E D F O R 5 -TO N CR A N E 30 ' x 1 6 ' O H D 30 ' x 1 6 ' S H E E T E D F O 30 ' x 1 6 ' O H D 16 ' - 0 " 12' - 0" 15 ' - 0 " 30 ' - 0 " 15' - 0" 13 ' - 6 " 11 ' - 6 " 11' - 2" 12' - 0" 10 0 ' - 0 " -Special Inspections by Connect Engineering -Exit Lighting and Signs will Comply with Section 1008 and 1013 -Doors will meet Section 1010 Shop Space F-1 Occupancy 306 Factory-Machinery/Metals Type II-B Construction 24 person Occupancy 12,000/500=24 Table 1004.5 15,500 S.F. allowed area Table 506.2 (NS, Type II B) No fire Sprinklers required under 12,000 s.f. 903.2.4 1 Male Water Closet & 1 Female Water Closet/100 location TBD 2902.1 Business Space B Occupancy 304.1 Business Group Type V-B Construction 33 person Occupancy (50 x 50 x 2)/150=33 Table 1004.5 9,000 S.F. allowed area Table 506.2 (NS, Type V-B) 2 Male Water Closets & 2 Female Water Closets -1ea per 25. location TBD section 2902.1 Office 120' - 0" 2 hr fire partition wall 50' - 0" 50 ' - 0 " Re v . 6/ 2 / 2 0 2 2 7: 1 0 : 5 8 A M FL O O R P L A N Au t h o r TR I S T E E L RE A L E S T A T E A1 0 2 1/16" = 1'-0"1 100 100 0' -0" 126 26' -0" 102 2' -0" A B C D HF 120 20' -0" CHARCOAL POLAR WHITE WHITE BRONZE 112 12' -0" 100 0' -0" 126 26' -0" 102 2' -0" ABCDH 29' - 6" 1" / 1'-0" 120 20' -0" G E 112 12' -0" Re v . 6/ 2 / 2 0 2 2 7: 1 0 : 5 9 A M EL E V A T I O N Au t h o r TR I S T E E L RE A L E S T A T E A1 0 3 3/32" = 1'-0"2 North 3/32" = 1'-0"1 South 100 0' -0" 126 26' -0" 102 2' -0" 4 3 2 18657 120 20' -0" 112 12' -0" 100 0' -0" 126 26' -0" 102 2' -0" 4321 8657 120 20' -0" 112 12' -0" Re v . 6/ 2 / 2 0 2 2 7: 1 0 : 5 9 A M EL E V A T I O N Au t h o r TR I S T E E L RE A L E S T A T E A1 0 4 1/16" = 1'-0"1 East 1/16" = 1'-0"2 West UP 12'x12' OHD X-BRACE X-BRACE 30 ' x 1 6 ' O H D 30 ' x 1 6 ' S H E E T E D F O 30 ' x 1 6 ' O H D 6'-6"x7'-0" FO3'-6"x7'-0" WD(2) 1'-6"x7' LITES 16 ' - 0 " 12' - 0" 15 ' - 0 " 30 ' - 0 " 15' - 0" 13 ' - 6 " 11 ' - 6 " 11' - 2" 12' - 0"7' - 4" 480' - 0" 10 0 ' - 0 " Entrance 80 ' - 0 " 460' - 0" 64 ' - 0 " 646' - 0" 120' - 0" 50' - 0" 50 ' - 0 " East Side Drive 5000 S 39 ' - 0 " North Driveway area UP 12'x12' OHD X-BRACE X-BRACE DE S I G N E D F O R 5 -TO N CR A N E 30 ' x 1 6 ' O H D 30 ' x 1 6 ' S H E E T E D F O 30 ' x 1 6 ' O H D 16 ' - 0 " 12' - 0" 15 ' - 0 " 30 ' - 0 " 15' - 0" 13 ' - 6 " 11 ' - 6 " 11' - 2" 12' - 0" 10 0 ' - 0 " -Special Inspections by Connect Engineering -Exit Lighting and Signs will Comply with Section 1008 and 1013 -Doors will meet Section 1010 Shop Space F-1 Occupancy 306 Factory-Machinery/Metals Type II-B Construction 24 person Occupancy 12,000/500=24 Table 1004.5 15,500 S.F. allowed area Table 506.2 (NS, Type II B) No fire Sprinklers required under 12,000 s.f. 903.2.4 1 Male Water Closet & 1 Female Water Closet/100 location TBD 2902.1 Business Space B Occupancy 304.1 Business Group Type V-B Construction 33 person Occupancy (50 x 50 x 2)/150=33 Table 1004.5 9,000 S.F. allowed area Table 506.2 (NS, Type V-B) 2 Male Water Closets & 2 Female Water Closets -1ea per 25. location TBD section 2902.1 Office 120' - 0" 2 hr fire partition wall 50' - 0" 50 ' - 0 " Cross=slope=of=sidewalks=and=landings=at=doors=not=to= exceed=OB=slope.= lne=parking=stall=to=be=designated=as=AaA=parking=and=will= need=to=be=van=accessible.=NNMS.R= manic=hardware=required=on=egress=doors=due=to=occupant= load=of=building=being=over=RM.= ptairs=risers=4"-T".=ptair=treads=NN"=min.=iandings=to=be=in= compliance.= eandrails=on=both=sides=of=stairs=and=meet=requirements=of= sectionNMNN.= fire=rated=door= pecond=level=floor=plan.= cire=wall=will=need=to=meet=one=of=the=exceptions=in=TMS=or= have=four=feet=of=protection=on=each=side=of=fire=wall.= A1031 A104 A103 A104 1 2 2 A B C D 4 32 1 H 8 6 5 7 F G E Entrance 24' Minimum drive isle around building Drainfield Area East Side Drive North All fire department access roads need to be able to drivable year round and with stand a 75,000 lb weight limit.