Loading...
HomeMy WebLinkAboutREVISED DRAWINGS - 22-00588 - Cedar Point Trucking - New Commercial BldgJOBNO LOCATION CUSTOMER BUILDER PROJECT BUILDERS PO# VP BUILDINGS VARCO PRUDEN DATE DRAWN / CHECK PAGE VPC VERSION: FILENAME VP Buildings 3200 Players Club Circle Memphis TN 38125 Codes and Loads Standard Erection Details Special Drawings Covering Secondary Structural Primary Structural Anchor Rod Plan Cover Sheet PAGESDRAWING TITLE DRAWING INDEX DESCRIPTIONDATETYPE DRAWING RELEASE HISTORY DESIGN CATEGORY D, E OR F. SEE CODES AND LOADS SECTION BELOW FOR DETAILS. PRE-TENSION A325 BOLTS IF LOCATED IN HIGH SEISMIC AREAS. FOR IBC BASED CODES; HIGH SEISMIC IS "SNUG-TIGHT" EXCEPT AS FOLLOWS; IN CANADA, ALL A325 AND A490 BOLTS SHALL BE "PRE-TENSIONED", EXCEPT FOR SECONDARY MEMBERS AND FLANGE BRACES. PRE-TENSION A325 BOLTS IF BUILDING SUPPORTS MACHINERY THAT CREATES VIBRATION, IMPACT, OR STRESS IT IS THE RESPONSIBILITY OF THE ERECTOR TO ENSURE PROPER BOLT TIGHTNESS IN ACCORDANCE WITH APPLICABLE REGULATIONS. SEE RCSC SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH STRENGTH BOLTS FOR MORE INFORMATION. SEE ERECTION GUIDE FOR BOLT TIGHTENING INSTRUCTIONS. THE FOLLOWING CRITERIA MAY BE USED TO DETERMINE THE BOLT TIGHTNESS (I.E.-SNUG TIGHT OR PRE-TENSION) UNLESS REQUIRED OTHERWISE BY LOCAL JURISDICTION OR CONTRACT. ALL A490 BOLTS SHALL BE "PRE-TENSIONED". A325 BOLTS IN PRIMARY FRAMING AND BRACING CONNECTIONS MAY BE PRE-TENSION A325 BOLTS IF BUILDING SUPPORTS A CRANE GREATER THAN 5 TON CAPACITY. REVERSALS ON CONNECTIONS. PRE-TENSION ANY CONNECTION WITH DESIGNATION A325-SC. SLIP CRITICAL (SC) CONNECTIONS MUST BE FREE OF PAINT, OIL OR OTHER MATERIALS THAT REDUCE FRICTION AT CONTACT SURFACES. GALVANIZED OR LIGHTLY RUSTED SURFACES ARE ACCEPTABLE. SECONDARY MEMBERS AND FLANGE BRACE CONNECTIONS ARE ALWAYS "SNUG TIGHT", UNLESS INDICATED OTHERWISE IN ERECTION DRAWING DETAILS. HOT ROLLED ANGLES A529, A572, A588, A992 GRADE 50 3 PLATE WELDED SECTIONS COLD FORMED LIGHT GAGE SHAPES BRACE RODS HOT ROLLED MILL SHAPES CLADDING A653, A792 A36, A529, A572, A588, A992 A572, A510 A653, A1011 A529, A572, A1011, A1018 GRADE 55 GRADE 60 GRADE 50 GRADE 36 OR 50 GRADE 50 OR GRADE 80 ASTM DESIGNATION GENERAL NOTES MATERIALS HIGH STRENGTH BOLT TIGHTENING REQUIREMENTS HOLLOW STRUCTURAL SECTION (HSS)A500 GRADE BR a division of BlueScope Buildings North America, Inc. VP BUILDINGS VARCO PRUDEN a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. Planograph Details Notes D INSPECTION AND TESTING THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. SPECIAL INSPECTIONS AND TESTING REQUIRED BY AUTHORITY HAVING JURISDICTION (AHJ) DURING CONSTRUCTION AND/OR STEEL FABRICATION IS THE RESPONSIBILITY OF THE OWNER OR OWNERS AUTHORIZED AGENT. WHEN REQUIRED, THE OWNER SHALL EMPLOY A QUALITY ASSURANCE AGENCY (QAA) APPROVED BY THE AHJ. THE BUILDER IS RESPONSIBLE TO COORDINATE BETWEEN THE QAA FIRM AND BBNA FABRICATION FACILITIES. THE TYPE AND EXTENT OF SPECIAL INSPECTIONS AND NDT WELD TESTING MUST BE SPECIFICALLY STIPULATED IN CONTRACT DOCUMENTS OR BBNA WILL ASSUME SPECIAL INSPECTIONS AND/OR NDT TESTING ARE WAIVED AS PERMITTED BY THE BUILDING CODE BASED ON BBNA FACILITIES IAS AC472 ACCREDITATION. COVER SHEET Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 1 CedarpointFinalR5.vpc1 2022.1b GPH 8:44:227/5/2022 Anchor Rod Drawings Rev0 07/11/2022 FOR CONSTRUCTION 07/11/2022Permit Drawings Rev0 PERMIT SET- For Building Dept. Approval 1 2 3 4-5 6-18 19-32 33-55 56-60 07/12/2022 Codes and Loads WHEN MULTIPLE BUILDINGS ARE INVOLVED, SPECIFIC LOAD FACTORS FOR DIFFERING OCCUPANCIES, BUILDING DIMENSIONS, HEIGHTS, FRAMING SYSTEMS, ROOF SLOPES, ETC., MAY RESULT IN DIFFERENT LOAD APPLICATION FACTORS THAN INDICATED BELOW. SEE CALCULATIONS FOR FURTHER DETAILS. WIND LOADS ARE APPLIED TO OVERALL BUILDING ENVELOPE. COMMON WALLS BETWEEN CONNECTED SHAPES ARE NOT SUBJECT TO EXTERNAL WIND LOADS. City: Rexburg County: Madison State: Idaho Country: United States Building Code Building Code: 2018 International Building Code Structural: 16AISC - ASD Rainfall: I: 4.00 inches per hour Building Risk/Occupancy Category: II (Standard Occupancy Structure)Cold Form: 16AISI - ASD f'c: 3000.00 psi Concrete Dead and Collateral Loads Collateral Gravity:3.00 psf Collateral Uplift: 0.00 psf Wind Load Wind Speed: Vult: 115.00 (Vasd: 89.08) mph The 'Envelope Procedure' is Used Primaries Wind Exposure: C - Kz: 0.897 Parts Wind Exposure Factor: 0.897 Wind Enclosure: Enclosed Topographic Factor: Kzt: 1.0000 Ground Elevation Factor: Ke: 0.8387 NOT Windborne Debris Region Base Elevation: 0/0/0 Site Elevation: 4860.0 ft Primary Zone Strip Width: 2a: 15/7/3 Parts / Portions Zone Strip Width: Walls, a: 7/9/10 Roof(s), 0.6h: N/A Velocity Pressure: qz: 21.65, (C&C) 21.65 psf Material Dead Weight Roof Covering + Second. Dead Load: Varies Frame Weight (assumed for seismic):2.50 psf Snow Load Ground Snow Load: pg: 50.00 psf Flat Roof Snow: pf: 31.50 psf Design Snow (Sloped): ps: 31.50 psf Rain Surcharge: 0.00 Specified Minimum Roof Snow: 35.00 psf Exposure Factor: 1 Fully Exposed - Ce: 0.90 Snow Importance: Is: 1.000 Thermal Factor: Heated - Ct: 1.00 Ground / Roof Conversion: 0.70 Unobstructed, Slippery Roof Live Load Roof Live Load: 20.00 psf Reducible Seismic Load Lateral Force Resisting Systems using Equivalent Force Procedure Mapped MCE Acceleration: Ss: 37.00 %g Mapped MCE Acceleration: S1: 14.20 %g Site Class: Stiff soil (D) - Default Seismic Importance: Ie: 1.000 Design Acceleration Parameter: Sds: 0.3710 Design Acceleration Parameter: Sd1: 0.2192 Seismic Design Category: D Seismic Snow Load: 6.30 psf % Snow Used in Seismic: 20.00 Diaphragm Condition: Rigid Fundamental Period Height Used: 22/9/0 Transverse Direction Parameters Ordinary Steel Moment Frames Redundancy Factor: Rho: 1.30 Fundamental Period: Ta: 0.3410 R-Factor: 3.50 Overstrength Factor: Omega: 3.00 Deflection Amplification Factor: Cd: 3.00 Base Shear: V: 0.1060 x W Longitudinal Direction Parameters Ordinary Steel Moment Frames Redundancy Factor: Rho: 1.30 Fundamental Period: Ta: 0.3410 R-Factor: 3.50 Overstrength Factor: Omega: 3.00 Deflection Amplification Factor: Cd: 3.00 Base Shear: V: 0.1060 x W JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\02 CedarpointFinalR5.vpc1_CODES AND LOADS PERMIT SET.dwg 7/8/2022 14:58:27SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. CODES AND LOADS 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 2NTS PERMIT SET- For Building Dept. Approval Y X 15x50'-6"x19'-6"(HS) Roof: A Y X 156 x100x26(HS) Roof: A 07/12/2022 07/12/2022 BUILDER/CONTRACTOR RESPONSIBILITIES VP Buildings follows the guidelines as outlined in the AISC and MBMA Codes of Standard Practice. PANELS Oil canning is an inherent characteristic of cold formed steel panels. It is the result of several factors that include induced stresses in the raw material delivered to VP, fabrication methods, installation procedures, and post installation thermal forces. Thru fastened panels will exhibit some dimpling when installed, especially when insulation is installed between panels and secondary supports. Dimpling can be minimized by careful installation, taking care not to over drive fasteners. springing back into place. All panels experience this action to some degree, especially with concealed clip Standing Seam panels. Roof rumble noise may be minimized by providing a layer of blanket insulation between the panels and any hard support surface such as steel secondary members, substrates such as plywood, steel decking, or rigid board insulation. A minimum of 3 inch thick blanket is recommended over steel secondary members, or 2 inch over substrates. Oil canning, dimpling, and roof rumble do not affect the structural integrity or weather tightness of the panels and is not grounds for rejection of panels. RAIN WATER RUNOFF Drainage systems must be designed by the project professional to comply with code requirements. VP is not responsible for drainage designs, overflow scuppers, down piping, etc. The project professional and contractor are responsible to ensure that primary drains and overflow devices such as scuppers and auxiliary drains are provided as required for the required rain intensity at Roof rumble is a phenomenon that is caused by wind gusts lifting up on the roof panels and then the building perimeter and at valley conditions to prevent ponding. However, it is imperative that installed Standing Seam panels be secured to the secondary The Standing Seam joint detail is designed with an interlocking feature for ease of installation. structural members and properly seamed prior to departure from the job site each day. SKYLIGHTS Local building departments may require added fall restraint due to conditions that may affect the skylight structural integrity. It is the responsibility of the builder to determine and provide any added fall restraint under the skylight as may be required by your building department. STEEL SHOP COAT The purpose of VP's shop coat is to provide protection for the steel members during transportation, during temporary job site storage and during erection. Standard shop formulation is not designed to perform as a finish coat when exposed to environmental conditions. Members shall be kept free of the ground and properly drained during job site storage. It is the Builder's responsibility to ensure that if a finish coat is being applied over VP shop coat that the painting contractor verifies compatibility between his finish coat and VP's shop coat. VP Buildings standard product specifications, design, fabrication, quality criteria shall govern all work unless stipulated otherwise in the contract documents. In case of discrepancies between VP Buildings structural plans and plans for other trades, VP Buildings structural plans shall govern. It is the responsibility of the Builder to obtain approvals and permits from all governing agencies and jurisdictions as required. Approval of VP Buildings drawings constitutes the builders acceptance of VP interpretation of the contract purchase order. Unless specific design criteria concerning interface design and details are furnished as part of the contract, VP Buildings design assumptions shall govern. CONSTRUCTION & ERECTION RESPONSIBILITY The Builder is responsible for construction in strict accordance with VP Buildings "FOR CONSTRUCTION" drawings and all applicable product installation guides. VP is not responsible for work done from any other VP drawings that are not marked "FOR CONSTRUCTION", nor any drawings prepared by others. As erected field assemblies of members shall be as specified in MBMA Code of Standard Practice (in Canada - CSA S16), which require L/500 tolerance of installed members. Occasional field work including shimming, cutting, coping, and drilling for final fit-up are considered part of erection. Specified field work and field welding conditions indicated on these drawings shall also be included in the erectors scope of work. See Erection Guide for shimming procedure. For building with top riding bridge cranes see Crane Data drawing for column plumb tolerance. The building erector shall be properly licensed and experienced in erecting metal building systems. The Builder is responsible for having knowledge of, and shall comply with, all OSHA requirements and all other governing site safety criteria. The builder is responsible for designing, supplying, locating and installing temporary supports and bracing during erection of the building. VP bracing is designed for code required loads after building completion and shall not be considered as adequate erection bracing. See Erection Guide. EXISTING STRUCTURES BRACING Tension brace rods work in pairs to balance forces caused by initial tensioning. Care must be taken while tightening brace rods so as not to cause accidental or misalignment of components. All rods must be installed loose and then tightened. Rods should not exhibit excessive sag. For long or heavy rods, or angles it may be necessary to support the rods at mid-bay by suspending them from secondary members. Bracing for seismic or wind loading of objects or equipment that are not a part of the VP structure must be designed by a qualified professional to deliver lateral loads to primary frames and rod bracing struts. Equipment bracing and suspension connections must not impose torsion or minor axis loads, or cause local distortion in any VP components. VP accepts no responsibility for design or installation of bracing systems not furnished by VP. FIELD WELDING All field welding shall be done at the direction of a design professional, and done in accordance with governing requirements (AWS in USA, CWB in Canada) by welders qualified to perform the welding as directed by the applicable welding procedure specification (WPS). A WPS shall be prepared by the contractor for each welding variation specified. The contractor is responsible for any special welding inspection as required by local jurisdiction. Filler metal shall be 70 ksi (480 MPa) tensile strength. For welds in high seismic force resisting system (Seismic Cat D, E or F), minimum Charpy V-Notch toughness shall meet AISC-341 criteria (20 ft-lbs min @ 0Deg F). Interpass temperatures shall not exceed 550Deg F (300Deg C). DELIVERIES It is the responsibility of the builder to have adequate equipment available at the job site to unload trucks in a safe and timely manner. The Builder will be responsible for all retention charges from carriers as a result of job site unloading delays. Claims for damage or shorts MUST be noted on the Bill-of-Lading or delivery receipt and filed against the carrier by the consignee as per VP's Terms of Sales (F.O.B. Plant) under the Uniform Commercial Code. It is critical that damages or shorts be noted on the Bill-of-Lading or you have little recourse with the carrier. Immediately upon delivery of material, material quantities are verified by the Builder against quantities billed on the shipping document. Neither the Manufacturer nor the carrier is responsible for material shortages against quantities billed on the shipping document if such shortages are not noted on the shipping documents upon delivery of material and acknowledged by the carriers agent. For materials concealed in bundles, boxes, or crates, shortages must be reported immediately upon unpacking. Should products get wet, bundled and crated materials must be unpacked and unbundled immediately to provide drainage of trapped moisture. See Erection Guide for proper job site storage procedure. SEALANTS Sealants shall be applied in strict accordance with VP details or weather tightness will be compromised. Sealant must be applied in temperatures and weather conditions consistent with labeling. INDEPENDENT MEZZANINES Independent mezzanines must be designed by a professional engineer. The engineer must ensure that proper isolation from the VP building has been provided to avoid structural damage due to differential movements, or inadvertently apply loads to the VP structure. VP accepts no responsibility for the design of the independent mezzanine. FIRE CODE COMPLIANCE It is the responsibility of the project design professional and builder to comply with local fire code regulations including consideration of, but not limited to, building use and occupancy, all building construction materials, separation requirements, egress requirements, fire protection systems, etc. Builder shall advise VP of any special requirements to be furnished by VP. FIELD MODIFICATIONS Modifications to this building from details and instructions contained on these drawings must be approved in writing by VP Buildings engineers, or other licensed structural engineer. This includes, but is not limited to, removal of roof or wall cladding, removing or moving any flange braces or rod braces, cutting of openings for doors, windows or RTU's, correction of fabrication errors, etc. The owner shall not impose loads to this structure beyond what is specified for this building in the contract documents. VP Buildings accepts no responsibility for the consequences of any unauthorized additions, alterations, or added loads to this structure. If the builder intends to invoice VP Buildings for modifications in excess of $1000, The builder must notify VP Buildings immediately, and obtain a Work Authorization from VP Buildings prior to proceeding. All final claims must be submitted to VP Buildings with all supporting documentation within 30 days of the building completion. Claims submitted without work authorizations, or after 30 days will not be accepted. Correction of minor misfits, shimming and plumbing, moderate amount of reaming, drilling, chipping / cutting and minor welding are considered by Code of Standard Practice to be part of erection are not subject to claim reimbursement. CONCRETE/MASONRY/CONVENTIONAL STUD WALLS The engineer responsible for the design of the wall system is responsible for coordinating with, or specifying to VP Buildings, any wall to steel compatibility issues such as drift and deflection compatibility, special base details, and wall to VP steel connections. All fasteners, sealant and counter flashing of wall systems are to be provided by contractor. The engineer responsible for the wall shall design the anchorage to VP supporting elements consistent with Code required forces. Dade Co. Product Approval (www.miamidade.gov/buildingcode) Approved Products Listed Under Varco Pruden Buildings, Inc. Underwriter's Laboratory Approvals (Available only when specified in contract) SSR Roof-UL#TGKX-113; SSR Composite Roof Class 90-UL#TGKX-113A; SSR Roof w/Super Block; Class 90-UL#TGKX-328; Panel Rib Roof UL Class 60-UL#TGKX-60; Panel Rib Roof UL Class 90-UL#TGKX-64; VP SLR II Roof Class 90-UL#TGKX-90, -180, -435, -435A, -176, -238, -238A, -238B Factory Mutual Approved Assemblies (Available only when specified in contract) SSR Roof Systems are approved in various type applications and listed in FM Approval Guide. 24 Ga SSR (0.0227" Nominal), is available in Class 1-60, 1-75, 1-90. 22Ga SSR (0.0277" Nominal), is available in Class 1-75, 1-90-, 1-120. ICC Evaluation Reports (www.icc-es.org) SSR Roof System - #ESR-2527 SLR II Roof Systems are approved in various type applications and listed in FM Approval Guide. 24 Ga SLR II (0.0227" Nominal), is available in Class 1-75 and 1-120. State of Florida Product Approvals (www.floridabuilding.org) VP TextureClad - See Transamerican Structuroc, Inc. VP TextureClad - See Transamerican Structuroc, Inc. Approved Products Listed Under VP Buildings, Inc. (http:/eng.cwbgroup.org/Certification/Pages/CertifiedCompanySearch.aspx) Canadian CSA A660 Certifications Listed under BlueScope Buildings North America, Inc. IAS AC472 Approvals: (www.iasonline.org/Metal_Building_Systems/MB.html) Fabricator Approvals MO#E-2010007736; NC#F-0998; OK#CA4170PE; SD#C-1787; TX#F4828; WV#C03059-00; Engineering Certifications of Authorization USA--AR#576; FL#30427; ID#C-2470; IL#184-002649; KS#E-29; MS#E-0592; CAN--AB#P08900; NS#30123; ON#100148796; and YT#PP134 VP BUILDINGS ACCREDITATIONS AND APPROVALS City of Los Angeles, CA #FB00031; City of Houston, TX 767 & 429; City of Phoenix, AZ C19-02008; Clark County, NV 43 & 833, San Bernardino County, CA 289 Listed under BlueScope Buildings North America, Inc. Listed under Varco Pruden Buildings, a Division of BlueScope Buildings North America, Inc. IAS AC472 Approvals: (www.iasonline.org/Metal_Building_Systems/MB.html) Design Approvals SIGNAGE The Builder is responsible for furnishing signs as required by Code and the Building Department, including but not limited to, exits, occupancy limits, floor loading limits, and bulk storage limits. Floor loading signs shall clearly indicate maximum floor live load permitted. Bulk storage facilities shall have signs clearly posted on all loaded walls indicating the type of commodity stored and the maximum storage height. Signs shall be clearly visible when building is fully loaded to design level. Overloading of floors or walls may result in failure. State of Utah, City of Richmond, CA. VP engineers are not Project Engineers or Engineer of Record for the overall project. VP engineering supply sealed engineering design data and drawings for VP supplied material as part of the overall project for use by others to obtain permits, approvals, and coordinate with other trades. All interface and/or compatibility of any materials not furnished by VP are to be considered and coordinated by the builder or A/E firm. VP must be advised of any structure that is within 20 ft. of VP's building. Load effects from snow drifting, wind effects, and seismic separation must be considered for both the new and existing structures. VP has designed the new VP building for these effects. The owner/builder are responsible for employing a Professional Engineer to review and verify the existing structure for all load effects from the adjacent VP building. VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D ERECTION NOTES Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 3 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 8:44:257/5/2022 07/12/2022 1 2'-6" 2 3'-6" 3 6" 4 8" 5 2'-7" 6 1'-5" Dimension Key 1 2'-6" 2 3'-6" 3 6" 4 8" 5 2'-7" 6 1'-5" Dimension Key Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\ARD\04 CedarpointFinalR5.vpc1_ANCHOR ROD PLAN.dwg 7/11/2022 14:59:14SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. ANCHOR ROD PLAN 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 4NTS <*> THE BUILDING IS DESIGNED WITH BRACING DIAGONALS IN THE DESIGNATED BAYS. COLUMN BASE REACTIONS, BASE PLATES AND ANCHOR RODS ARE AFFECTED BY THIS BRACING AND DIAGONALS MAY NOT BE RELOCATED WITHOUT CONSULTING THE BUILDING SUPPLIERS ENGINEER. PERMIT SET- For Building Dept. Approval BL 54 BL 32 BL 1 BLJ G F E D C BLB BLA ANCHOR ROD PLAN AR1-1 AR1-1 AR1-1 D1D1 AR1-1 AR1-1 AR4-1 AR4-2 AR1 AR1 AR4-1 AR4-2 AR1 AR1 AR4-1 AR4-2 AR1 AR1 AR1-1 AR1-1 AR9 AR9 3 24'-6"25'-0"3 6 J= 8 . 5 0 11 ' - 0 " 5 50'-6" 15 ' - 0 " 52 ' - 0 " 52 ' - 0 " 52 ' - 0 " 324'-6"25'-0"25'-0"24'-6"3 J= 8 . 5 0 16 ' - 0 " 1 2 J= 8 . 5 0 16 ' - 0 " 6' - 6 " 6' - 6 " J= 8 . 5 0 16 ' - 0 " 2 1 J= 8 . 5 0 16 ' - 0 " 7' - 6 " 26 ' - 0 " 26 ' - 0 " 26 ' - 0 " 26 ' - 0 " 26 ' - 0 " 26 ' - 0 " 4 J=8.50 8'-4"16'-0" 49'-6" 7' - 6 " J= 8 . 5 0 16 ' - 0 " 1 2 J= 8 . 5 0 16 ' - 0 " 6' - 6 " 6' - 6 " J= 8 . 5 0 16 ' - 0 " 2 1 J= 8 . 5 0 16 ' - 0 " 26 ' - 0 " 26 ' - 0 " 26 ' - 0 " 26 ' - 0 " 26 ' - 0 " 26 ' - 0 " 100'-0" 15 6 ' - 0 " PARTITION WALL 8" TILT WALL (NBVP) 8" TILT WALL (NBVP)8" TILT WALL (NBVP) 8" TILT WALL (NBVP) PARTITION WALL AR1-2 AR1-2 AR1-2 AR1-2 AR1-2 AR1-2 AR1-2 AR1-2 AR1-2 AR1-2 6' 10 3 ' - 7 3 / 4 " to F a c e o f P a r t i t i o n W a l l to Face of Partition Wall 07/12/2022 AR1 (4)3/4" Dia. Max Plate W=8",L=1'-1", Min Thk=3/8" Dim: A=1'-0" Elev.=100'-0" AR1-1 (4)3/4" Dia. Max Plate W=8",L=1'-1", Min Thk=3/8" Dim: A=1'-0" Elev.=102'-0" AR4-1 (4)3/4" Dia. Max Plate W=8",L=10", Min Thk=3/8" Elev.=102'-0" AR4-2 (4)3/4" Dia. Max Plate W=9",L=10", Min Thk=3/8" Elev.=99'-6" AR9 (4)1" Dia. Max Plate W=9",L=1'-7", Min Thk=1/2" Dim: A=11 1/2" B=1'-1" Gage=5" Pitch=5" Edge Out=4" Elev.=100'-0" D1 (4)1" Dia. Max Plate W=1'-0",L=1'-7", Min Thk=1/2" Dim: A=11 1/2" B=1'-1 1/2" Gage=5" Pitch=5" Edge Out=4" Elev.=100'-0" VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D ANCHOR ROD PLAN - DETAILS Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 5 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 8:44:277/5/2022 07/12/2022 Rod, Strut, and Misc. Connection Bolts I d Qty Grade Bolt Diam.Bolt Length PartNo 1 2 A325 3/4"2 1/2"0097284 1 6" Dimension Key Bracing Part Schedule Part Qty Length Detail 3BSE2310714 3 24'-4 7/8"BR15L1 07RS3505 2 35'-5"BR01G2 06RS3504 4 35'-4"BR01G2 03RS3504 2 35'-4"BR01G2 04RS3900 2 39'-0"BR01G2 07RS3405 2 34'-5"BR01G2 3BSA2310711 1 24'-4 7/8"BR15L1 14RU2804 2 28'-4"BR02K1 Shape Name = 156 x100x26(HS), Shape = 15x50'-6"x19'-6"(HS) JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\06 CedarpointFinalR5.vpc1_PRIMARY AND ROOF BRACING PLAN PERMIT.dwg 7/11/2022 15:30:10SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. PRIMARY AND ROOF BRACING PLAN 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 6NTS 1. USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS, UNLESS NOTED OTHERWISE. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME SIDE OF THE WEB AS THE HILLSIDE WASHER. PERMIT SET- For Building Dept. Approval PRIMARY AND ROOF BRACING PLAN BL 54 BL 32 BL 1 BLJ G F E D C BLB BLA RB X 0 2 8 RB X 0 3 1 CX013 RB X 0 3 0 RB X 0 2 9 CX012 RB X 0 2 8 RB X 0 2 7 CX011 CX015 RBX033 CX015 EPX010 EPX009 EPX008 EPX007 EPX006 CX010 RB X 0 2 6 RB X 0 2 5 RB X 0 0 5 RB X 0 0 4 RB X 0 0 3 RB X 0 2 4 RB X 0 2 3 CX009 ICX006 ICX005 CX008 RB X 0 2 2 RB X 0 2 1 RB X 0 2 0 RB X 0 1 9 RB X 0 1 8 CX007 ICX004 ICX003 CX006 RB X 0 1 7 RB X 0 1 6 RB X 0 1 5 RB X 0 1 4 RB X 0 1 3 CX005 ICX002 ICX001 CX004 RB X 0 1 2 RB X 0 1 1 RB X 0 1 0 RB X 0 0 9 RB X 0 0 8 CX003 EPX005 EPX004 EPX003 EPX002 EPX001 CX002 RB X 0 0 7 RB X 0 0 6 RB X 0 0 5 RB X 0 0 4 RB X 0 0 3 RB X 0 0 2 RB X 0 0 1 CX001 CX014 RBX032 CX014 11 11 11 11 1 24'-6"25'-0" 1 50'-6" 15 ' - 0 " 1 4 R U 2 8 0 4 14R U 2 8 0 4 1 24'-6"25'-0"25'-0"24'-6" 1 26 ' - 0 " 26 ' - 0 " 26 ' - 0 " 26 ' - 0 " 26 ' - 0 " 26 ' - 0 " 49'-6" 26 ' - 0 " 26 ' - 0 " 26 ' - 0 " 26 ' - 0 " 26 ' - 0 " 26 ' - 0 " 100'-0" 15 6 ' - 0 " 3BSA2310711 0 7 R S 3 4 0 5 07R S 3 4 0 5 3BSE2310714 0 6 R S 3 5 0 4 06R S 3 5 0 4 0 4 R S 3 9 0 0 04 R S 3 9 0 0 0 3 R S 3 5 0 4 03R S 3 5 0 4 0 6 R S 3 5 0 4 06R S 3 5 0 4 3BSE2310714 0 7 R S 3 5 0 5 07R S 3 5 0 5 3BSE2310714 07/12/2022 Frame Member Schedule Part Mem Width Thick WebThk.Depth1 Depth2 Approx.Lgth Approx.Weight CX016 1 8.0000 .3750 .1644 1'-6"1'-6"18'-6 1/16"675# 2 8.0000 .3750 .2500 1'-6"1'-6" RBX032 3-4 8.0000 .3750 .1345 2'-0"2'-0"20'-6 3/4"776# CX016 5 8.0000 .3750 .2500 1'-6"1'-6"18'-6 1/16"675# 6 8.0000 .3750 .1644 1'-6"1'-6" Id Qty Grade Bolt Bolt Plate Rows Rows Tension Washer PartNo Dia.Length Thick.Out In Bolt A 12 F1852 1"3 1/2"1"3 3 Yes Yes 0097546 B 2 F1852 3/4"3"3/8"Yes Yes 0097392 Bolt Connection & Plate Schedule 1 8" 2 1'-0 1/2" Dimension Key Frame Clearances Horiz. Clearance between members 1(CX016) and 5(CX016): 20'-8" Horiz. Clearance between members 1(CX016) and 6(CX016): 20'-8" Horiz. Clearance between members 2(CX016) and 5(CX016): 20'-8" Horiz. Clearance between members 2(CX016) and 6(CX016): 20'-8" Vert. Clearance at member 2(CX016): 16'-2 5/16" Vert. Clearance at member 5(CX016): 16'-2 5/16" Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) Shape Name = 156 x100x26(HS) Wall 2, Frame 2 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\07 CedarpointFinalR5.vpc1_PORTAL FRAME ELEVATION ALONG B.dwg 7/8/2022 15:04:37SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. PORTAL FRAME ELEVATION ALONG B 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 7NTS 1. USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS, UNLESS NOTED OTHERWISE. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME SIDE OF THE WEB AS THE HILLSIDE WASHER. PERMIT SET- For Building Dept. Approval A A CX 0 1 6 RBX032 CX 0 1 6 HFB3060HFB3060 PORTAL FRAME ELEVATION ALONG B 34 2 18 ' - 6 1 / 1 6 " 23'-8"1 1 25'-0" B B 07/12/2022 Frame Member Schedule Part Mem Width Thick WebThk.Depth1 Depth2 Approx.Lgth Approx.Weight Detail CX001 1 5.0000 .1875 .1345 1'-0"2'-0"23'-3 1/8"388# RBX001 2 5.0000 .1875 .1345 1'-3"9"12'-7 3/4"169# RBX002 3 5.0000 .1875 .1345 9"10"20'-0"228# 4 5.0000 .1875 .1345 10"9" RBX003 5 5.0000 .1875 .1345 9"1'-0"27'-0"315# 6 5.0000 .1875 .1345 1'-0"9" RBX004 7 5.0000 .1875 .1345 9"1'-0"25'-8 5/16"301# 8 5.0000 .1875 .1345 1'-0"9" RBX005 9 5.0000 .1875 .1345 9"1'-0"26'-0 1/4"304# 10 5.0000 .1875 .1345 1'-0"9" RBX006 11 5.0000 .1875 .1345 9"1'-0"26'-0 1/4"305# 12 5.0000 .1875 .1345 1'-0"9" RBX007 13 5.0000 .1875 .1345 9"1'-7"13'-4 5/16"197# CX002 14 5.0000 .2500 .1345 1'-0"2'-0"16'-10 13/16"335# EPX001 15 5.0000 .1345 .1644 1'-0"1'-0"21'-4 5/8"266#BR25A3 EPX002 16 5.0000 .1345 .1644 1'-0"1'-0"20'-1 11/16"251#BR25CA EPX003 17 5.0000 .1345 .1345 1'-0"1'-0"19'-0 11/16"218#BR25CA EPX004 18 5.0000 .1345 .1345 1'-0"1'-0"17'-11 11/16"208#BR25CA EPX005 19 5.0000 .1345 .1345 1'-0"1'-0"16'-10 11/16"193#BR25CA Id Qty Grade Bolt Bolt Plate Rows Rows Tension Washer PartNo Dia.Length Thick.Out In Bolt A 10 F1852 3/4"2"3/8"2 3 Yes Yes 0097388 B 6 F1852 3/4"2"3/8"1 2 Yes Yes 0097388 C 4 F1852 3/4"2 1/4"1/2"1 1 Yes Yes 0097389 D 10 F1852 3/4"2 1/4"1/2"2 3 Yes Yes 0097389 E 4 A325 1/2"1 1/2"3/8"1 1 49080 <S> - (2) Washers (095872) req'd at Flange Brace to Secondary. Bolt Connection & Plate Schedule 1 8 1/2" 2 4'-0" 3 3'-2" 4 3'-10" 5 1'-4 7/8" 6 2 @ 4'-10 3/8" 7 2 @ 5'-0" 8 2'-4" Dimension Key Frame Clearances Horiz. Clearance between members 1(CX001) and 14(CX002): 150'-6 7/8" Vert. Clearance at member 1(CX001): 23'-8 1/4" Vert. Clearance at member 14(CX002): 17'-0 15/16" Vert. Clearance at member 15(EPX001): 23'-4 9/16" Vert. Clearance at member 16(EPX002): 22'-1 5/8" Vert. Clearance at member 17(EPX003): 21'-0 5/8" Vert. Clearance at member 18(EPX004): 19'-11 5/8" Vert. Clearance at member 19(EPX005): 18'-10 5/8" Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) Shape Name = 156 x100x26(HS) Wall 4, Frame 1 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\08 CedarpointFinalR5.vpc1_FRAME CROSS SECTION AT FRAME LINE(S) 1 (a) PERMIT.dwg 7/11/2022 15:32:47SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. FRAME CROSS SECTION AT FRAME LINE(S) 1 (a) 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 8NTS 1. USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS, UNLESS NOTED OTHERWISE. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME SIDE OF THE WEB AS THE HILLSIDE WASHER. PERMIT SET- For Building Dept. Approval 102'-0"102'-0"102'-0"102'-0"102'-0"102'-0"102'-0" E E E E E D C B B B B BA EP X 0 0 5 EP X 0 0 4 EP X 0 0 3 EP X 0 0 2 EP X 0 0 1 C X 0 0 2 RBX007 RBX006 RBX005 RBX004 RBX003 RBX002RBX001 CX 0 0 1 GFB2046 1 WBBC2WBBC2 KMA1 GC175120 GF B 2 0 5 4 GF B 2 0 2 7 GF B 2 0 2 2 < S > GF B 2 0 2 2 < S > GF B 2 0 2 7 GF B 2 0 2 2 < S > GF B 2 0 4 6 < S > GF B 2 0 3 7 GF B 2 0 4 3 < S > GF B 2 0 4 6 < S > GF B 2 0 3 7 GF B 2 0 4 2 < S > GF B 2 0 4 7 < S > GF B 2 0 5 0 GF B 2 0 3 7 GF B 2 0 3 7 < S > GF B 2 0 3 5 GF B 2 0 5 0 FB L C 2 FB L C 2 FB L C 2 FB L C 2 FB L C 2 FB L C 2 EA P 2 DJ C 2 1 DJ C 2 1 DJ C 2 1 DJ C 2 1 DJ C 2 1 DJ C 2 1 DJ C 2 1 GFB2066 GFB2032 1 WBBC2WBBC2 KMA1 WBBC2WBBC2 KMA1 FRAME CROSS SECTION AT FRAME LINE(S) 1 C CL D CL E CL F CL G CL BL B BL J 156'-1 5/8" 0.5000:12 19 ' - 6 " 26 ' - 0 " 8 7 3 2 6 29 @ 5'-0" 5 4 3 @ 5 ' - 0 " 3 2 156'-0" 26'-0"26'-0"26'-0"26'-0"26'-0"26'-0" 07/12/2022 Frame Member Schedule Part Mem Width Thick WebThk.Depth1 Depth2 Approx.Lgth Approx.Weight Detail CX003 1 5.0000 .3750 .1345 1'-0"2'-0"25'-3 1/8"582# RBX008 2 6.0000 .2500 .1345 2'-3"1'-11"39'-7 15/16"934# 3 6.0000 .3125 .1345 1'-11"1'-11" RBX009 4 6.0000 .3750 .1875 1'-11"3'-6"23'-0"868# 5 6.0000 .3750 .1875 3'-6"1'-4" RBX010 6 6.0000 .3125 .1644 1'-4"1'-4"30'-0"670# RBX011 7 6.0000 .3750 .1875 1'-4"3'-3"20'-0"762# 8 6.0000 .3750 .1875 3'-3"2'-1" RBX012 9 6.0000 .3750 .1345 2'-1"2'-1"38'-1 7/16"1009# 10 6.0000 .2500 .1345 2'-1"2'-0" CX004 11 5.0000 .3125 .1345 1'-0"2'-0"18'-10 3/4"407# ICX001 12 8.0000 .3750 .1644 8 1/2"8 1/2"20'-2 11/16"528#BRxxxx ICX002 13 6.0000 .3750 .1345 8 1/2"8 1/2"15'-9 1/8"343#BRxxxx Id Qty Grade Bolt Bolt Plate Rows Rows Tension Washer PartNo Dia.Length Thick.Out In Bolt A 12 F1852 3/4"2"3/8"3 3 Yes Yes 0097388 B 10 F1852 3/4"2"3/8"4 1 Yes Yes 0097388 C 6 F1852 3/4"2"3/8"2 1 Yes Yes 0097388 D 8 F1852 3/4"2 1/4"1/2"3 1 Yes Yes 0097389 E 14 F1852 3/4"2 1/4"1/2"4 3 Yes Yes 0097389 F 8 F1852 3/4"2 1/2"5/8"2 2 Yes Yes 0097390 Bolt Connection & Plate Schedule 1 8 1/2" 2 4'-0" 3 3'-2" 4 3'-10" 5 1'-4 7/8" 6 2 @ 4'-10 3/8" 7 2 @ 5'-0" 8 2'-4" Dimension Key Frame Clearances Horiz. Clearance between members 1(CX003) and 11(CX004): 150'-6 7/8" Vert. Clearance at member 1(CX003): 22'-8 1/4" Vert. Clearance at member 11(CX004): 16'-7 15/16" Vert. Clearance at member 12(ICX001): 19'-7 13/16" Vert. Clearance at member 13(ICX002): 17'-8 11/16" Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) Shape Name = 156 x100x26(HS) Wall 4, Frame 2 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\09 CedarpointFinalR5.vpc1_FRAME CROSS SECTION AT FRAME LINE(S) 2 (a) PERMIT.dwg 7/11/2022 15:34:52SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. FRAME CROSS SECTION AT FRAME LINE(S) 2 (a) 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 9NTS 1. USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS, UNLESS NOTED OTHERWISE. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME SIDE OF THE WEB AS THE HILLSIDE WASHER. PERMIT SET- For Building Dept. Approval 102'-0" lo n g s i d e 99'-6" lo n g s i d e F F E C D C B A IC X 0 0 2 IC X 0 0 1 CX 0 0 4 RBX012 RBX0 1 1 RBX010RBX00 9 RBX008 CX 0 0 3 (2)GFB2046 GFB2032 1 WBBC2 KMA1 WBBC2 WBBC2 KMA1 WBBC2 (2 ) G F B 2 0 8 6 GF B 2 0 8 6 GF B 2 0 8 6 GF B 2 0 8 6 (2 ) G F B 4 0 1 5 (2 ) G F B 4 0 2 7 GF B 2 0 6 3 GF B 2 0 6 3 GF B 3 0 0 0 (2 ) G F B 4 0 9 3 GF B 3 0 0 0 GF B 3 0 0 0 GF B 3 0 0 0 (2 ) G F B 3 0 0 0 FB L C 2 FB L C 2 FB L C 2 FB L C 2 FB L C 2 ES B S B EA P 1 ES B S A (2)GFB2066 GFB2046 GFB2032 GFB2016 1 WBBC2WBBC2 KMA1 WBBC2WBBC2 KMA1 WBBC2WBBC2 KMA1 WBBC2WBBC2 KMA1 FRAME CROSS SECTION AT FRAME LINE(S) 2 BL B BL J 156'-1 5/8" 0.5000:12 19 ' - 6 " 26 ' - 0 " 8 7 3 2 6 29 @ 5'-0" 5 4 3 @ 5 ' - 0 " 3 2 156'-0" 52'-0"52'-0"52'-0" 07/12/2022 Frame Member Schedule Part Mem Width Thick WebThk.Depth1 Depth2 Approx.Lgth Approx.Weight Detail CX005 1 5.0000 .3125 .1644 1'-0"2'-0"25'-3 1/8"590# RBX013 2 6.0000 .2500 .1345 2'-1"2'-1"39'-7 7/8"968# 3 6.0000 .3125 .1345 2'-1"2'-1" RBX014 4 6.0000 .3750 .1875 2'-1"3'-5"23'-0"862# 5 6.0000 .3750 .1875 3'-5"1'-3" RBX015 6 6.0000 .3750 .1345 1'-3"1'-3"30'-0"683# RBX016 7 6.0000 .3750 .1875 1'-3"3'-3"20'-0"754# 8 6.0000 .3750 .1875 3'-3"2'-0" RBX017 9 6.0000 .3750 .1345 2'-0"2'-0"38'-1 5/16"991# 10 6.0000 .2500 .1345 2'-0"1'-9" CX006 11 5.0000 .3125 .1345 1'-0"2'-0"18'-10 13/16"428# ICX003 12 8.0000 .3750 .1644 8 1/2"8 1/2"20'-3 11/16"530#BRxxxx ICX004 13 6.0000 .3750 .1345 8 1/2"8 1/2"15'-9 3/16"343#BRxxxx Id Qty Grade Bolt Bolt Plate Rows Rows Tension Washer PartNo Dia.Length Thick.Out In Bolt A 12 F1852 3/4"2"3/8"3 3 Yes Yes 0097388 B 8 F1852 3/4"2"3/8"3 1 Yes Yes 0097388 C 6 F1852 3/4"2"3/8"2 1 Yes Yes 0097388 D 8 F1852 3/4"2 1/4"1/2"3 1 Yes Yes 0097389 E 14 F1852 3/4"2 1/4"1/2"4 3 Yes Yes 0097389 F 8 F1852 3/4"2 1/2"5/8"2 2 Yes Yes 0097390 Bolt Connection & Plate Schedule 1 8 1/2" 2 3'-10" 3 1'-4 7/8" 4 2 @ 4'-10 3/8" 5 2 @ 5'-0" 6 2'-4" Dimension Key Frame Clearances Horiz. Clearance between members 1(CX005) and 11(CX006): 150'-6 7/8" Vert. Clearance at member 1(CX005): 22'-10 1/4" Vert. Clearance at member 11(CX006): 16'-10 15/16" Vert. Clearance at member 12(ICX003): 19'-8 13/16" Vert. Clearance at member 13(ICX004): 17'-8 11/16" Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) Shape Name = 156 x100x26(HS) Wall 4, Frame 3 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\10 CedarpointFinalR5.vpc1_FRAME CROSS SECTION AT FRAME LINE(S) 3 (a) PERMIT.dwg 7/11/2022 15:36:15SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. FRAME CROSS SECTION AT FRAME LINE(S) 3 (a) 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 10NTS 1. USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS, UNLESS NOTED OTHERWISE. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME SIDE OF THE WEB AS THE HILLSIDE WASHER. PERMIT SET- For Building Dept. Approval 102'-0" lo n g s i d e 99'-6" lo n g s i d e F F E B D C B A IC X 0 0 4 IC X 0 0 3 C X 0 0 6 RBX017 RBX 0 1 6 RBX015RBX01 4 RBX013 CX 0 0 5 GFB2046 GFB2032 1 WBBC2WBBC2 KMA1 WBBC2WBBC2 KMA1 (2 ) G F B 2 0 6 7 GF B 2 0 8 6 GF B 2 0 8 6 GF B 2 0 8 6 (2 ) G F B 4 0 1 5 (2 ) G F B 4 0 2 7 GF B 2 0 6 3 GF B 2 0 6 3 GF B 2 0 9 7 (2 ) G F B 4 0 7 1 GF B 3 0 0 0 GF B 3 0 0 0 GF B 3 0 0 0 (2 ) G F B 3 0 0 0 FB L C 2 FB L C 2 FB L C 2 FB L C 2 FB L C 2 ES B S B EA P 1 ES B S A GFB2066 GFB2046 GFB2032 GFB2016 1 WBBC2WBBC2 KMA1 WBBC2WBBC2 KMA1 WBBC2WBBC2 KMA1 WBBC2WBBC2 KMA1 FRAME CROSS SECTION AT FRAME LINE(S) 3 BL B BL J 156'-1 5/8" 0.5000:12 19 ' - 6 " 26 ' - 0 " 6 5 7' - 2 " 4 29 @ 5'-0" 3 2 3 @ 5 ' - 0 " 7' - 2 " 156'-0" 52'-0"52'-0"52'-0" 07/12/2022 Frame Member Schedule Part Mem Width Thick WebThk.Depth1 Depth2 Approx.Lgth Approx.Weight Detail CX007 1 5.0000 .3750 .1345 1'-0"2'-0"25'-3 1/8"603# RBX018 2 6.0000 .2500 .1345 2'-0"1'-11"39'-7 13/16"1010# 3 6.0000 .3750 .1345 1'-11"1'-11" RBX019 4 6.0000 .3750 .1875 1'-11"3'-4"23'-0"851# 5 6.0000 .3750 .1875 3'-4"1'-4" RBX020 6 6.0000 .3125 .1644 1'-4"1'-4"30'-0"670# RBX021 7 6.0000 .3750 .1875 1'-4"3'-3"20'-0"767# 8 6.0000 .3750 .1875 3'-3"2'-2" RBX022 9 6.0000 .3750 .1345 2'-2"2'-2"40'-8 7/8"1103# 10 6.0000 .2500 .1345 2'-2"2'-0" CX008 11 5.0000 .2500 .1345 1'-0"2'-0"16'-10 9/16"318# ICX005 12 8.0000 .3750 .1644 8 1/2"8 1/2"20'-4 9/16"532#BRxxxx ICX006 13 5.0000 .3750 .1345 8 1/2"8 1/2"15'-9 1/16"296#BRxxxx Id Qty Grade Bolt Bolt Plate Rows Rows Tension Washer PartNo Dia.Length Thick.Out In Bolt A 8 F1852 3/4"2 1/4"1/2"2 2 Yes Yes 0097389 B 10 F1852 3/4"2"3/8"4 1 Yes Yes 0097388 C 6 F1852 3/4"2"3/8"2 1 Yes Yes 0097388 D 8 F1852 3/4"2 1/4"1/2"3 1 Yes Yes 0097389 E 8 F1852 3/4"2 1/2"5/8"2 2 Yes Yes 0097390 Bolt Connection & Plate Schedule 1 8 1/2" 2 4'-0" 3 3'-2" 4 3'-10" 5 1'-4 7/8" 6 2 @ 4'-10 3/8" 7 2 @ 5'-0" 8 2'-4" Dimension Key Frame Clearances Horiz. Clearance between members 1(CX007) and 11(CX008): 150'-7" Vert. Clearance at member 1(CX007): 23'-1 5/8" Vert. Clearance at member 11(CX008): 16'-10 9/16" Vert. Clearance at member 12(ICX005): 19'-9 13/16" Vert. Clearance at member 13(ICX006): 17'-8 5/8" Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) Shape Name = 156 x100x26(HS) Wall 4, Frame 4 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\11 CedarpointFinalR5.vpc1_FRAME CROSS SECTION AT FRAME LINE(S) 4 PERMIT.dwg 7/11/2022 15:39:11SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. FRAME CROSS SECTION AT FRAME LINE(S) 4 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 11NTS 1. USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS, UNLESS NOTED OTHERWISE. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME SIDE OF THE WEB AS THE HILLSIDE WASHER. PERMIT SET- For Building Dept. Approval 102'-0" lo n g s i d e 99'-6" lo n g s i d e E E A C D C B A IC X 0 0 6 IC X 0 0 5 C X 0 0 8 RBX022 RBX 0 2 1 RBX020RBX01 9 RBX018 CX 0 0 7 GFB2046 GFB2032 1 WBBC2 KMA1 WBBC2 WBBC2WBBC2 KMA1 (2 ) G F B 2 0 8 6 GF B 2 1 0 4 GF B 2 1 0 4 GF B 2 1 0 4 (2 ) G F B 4 0 1 5 (2 ) G F B 4 0 2 7 GF B 2 0 6 3 GF B 2 0 6 3 GF B 3 0 0 0 (2 ) G F B 4 0 7 1 GF B 3 0 0 0 GF B 3 0 0 0 GF B 3 0 0 0 (2 ) G F B 3 0 0 0 FB L C 2 FB L C 2 FB L C 2 FB L C 2 FB L C 2 ES B S B ES B S A GFB2066 GFB2046 GFB2032 GFB2016 1 WBBC2WBBC2 KMA1 WBBC2WBBC2 KMA1 WBBC2WBBC2 KMA1 WBBC2WBBC2 KMA1 FRAME CROSS SECTION AT FRAME LINE(S) 4 BL B BL J 156'-1 5/8" 0.5000:12 19 ' - 6 " 26 ' - 0 " 8 7 3 2 6 29 @ 5'-0" 5 4 3 @ 5 ' - 0 " 3 2 156'-0" 52'-0"52'-0"52'-0" 07/12/2022 Frame Member Schedule Part Mem Width Thick WebThk.Depth1 Depth2 Approx.Lgth Approx.Weight Detail CX009 1 5.0000 .1875 .1345 1'-0"2'-0"23'-3 1/8"389# RBX023 2 5.0000 .1875 .1345 1'-4"9"12'-7 5/8"172# RBX024 3 5.0000 .1875 .1345 9"11"20'-0"233# 4 5.0000 .1875 .1345 11"9" RBX003 5 5.0000 .1875 .1345 9"1'-0"27'-0"315# 6 5.0000 .1875 .1345 1'-0"9" RBX004 7 5.0000 .1875 .1345 9"1'-0"25'-8 5/16"301# 8 5.0000 .1875 .1345 1'-0"9" RBX005 9 5.0000 .1875 .1345 9"1'-0"26'-0 1/4"304# 10 5.0000 .1875 .1345 1'-0"9" RBX025 11 5.0000 .1875 .1345 9"1'-1"26'-0 1/4"310# 12 5.0000 .1875 .1345 1'-1"9" RBX026 13 5.0000 .1875 .1345 9"1'-5"16'-0"222# CX010 14 5.0000 .1875 .1345 1'-0"2'-0"15'-5 5/8"263# EPX006 15 5.0000 .1345 .1644 1'-0"1'-0"21'-3 5/8"265#BR25A3 EPX007 16 5.0000 .1345 .1644 1'-0"1'-0"20'-1 11/16"251#BR25CA EPX008 17 5.0000 .1345 .1345 1'-0"1'-0"19'-0 11/16"218#BR25CA EPX009 18 5.0000 .1345 .1345 1'-0"1'-0"17'-11 11/16"209#BR25CA EPX010 19 5.0000 .1345 .1345 1'-0"1'-0"16'-9 11/16"192#BR25CA Id Qty Grade Bolt Bolt Plate Rows Rows Tension Washer PartNo Dia.Length Thick.Out In Bolt A 8 F1852 3/4"2 1/4"1/2"2 2 Yes Yes 0097389 B 6 F1852 3/4"2"3/8"1 2 Yes Yes 0097388 C 14 F1852 3/4"2"3/8"3 4 Yes Yes 0097388 D 4 A325 1/2"1 1/2"3/8"1 1 49080 <S> - (2) Washers (095872) req'd at Flange Brace to Secondary. Bolt Connection & Plate Schedule 1 8 1/2" 2 4'-0" 3 3'-2" 4 3'-10" 5 1'-4 7/8" 6 2 @ 4'-10 3/8" 7 2 @ 5'-0" 8 2'-4" Dimension Key Frame Clearances Horiz. Clearance between members 1(CX009) and 14(CX010): 150'-7" Vert. Clearance at member 1(CX009): 23'-9 5/8" Vert. Clearance at member 14(CX010): 17'-5 5/8" Vert. Clearance at member 15(EPX006): 23'-3 9/16" Vert. Clearance at member 16(EPX007): 22'-1 5/8" Vert. Clearance at member 17(EPX008): 21'-0 5/8" Vert. Clearance at member 18(EPX009): 19'-11 5/8" Vert. Clearance at member 19(EPX010): 18'-9 11/16" Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) Shape Name = 156 x100x26(HS) Wall 4, Frame 5 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\12 CedarpointFinalR5.vpc1_FRAME CROSS SECTION AT FRAME LINE(S) 5 PERMIT.dwg 7/11/2022 15:40:38SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. FRAME CROSS SECTION AT FRAME LINE(S) 5 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 12NTS 1. USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS, UNLESS NOTED OTHERWISE. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME SIDE OF THE WEB AS THE HILLSIDE WASHER. PERMIT SET- For Building Dept. Approval 102'-0"102'-0"102'-0"102'-0"102'-0"102'-0"102'-0" D D D D D C B B B B B BA EP X 0 1 0 EP X 0 0 9 EP X 0 0 8 EP X 0 0 7 EP X 0 0 6 CX 0 1 0 RBX026 RBX025 RBX005 RBX004 RBX003 RBX024RBX023 CX 0 0 9 GFB2046 1 WBBC2WBBC2 KMA1 GF B 2 0 4 2 GF B 2 0 2 7 GF B 2 0 2 5 < S > GF B 2 0 2 4 < S > GF B 2 0 3 3 GF B 2 0 2 2 < S > GF B 2 0 4 6 < S > GF B 2 0 3 7 GF B 2 0 4 3 < S > GF B 2 0 4 6 < S > GF B 2 0 3 7 GF B 2 0 4 2 < S > GF B 2 0 4 7 < S > GF B 2 0 5 0 GF B 2 0 3 7 GF B 2 0 4 2 < S > GF B 2 0 4 0 GF B 2 0 6 3 FB L C 2 FB L C 2 FB L C 2 FB L C 2 FB L C 2 FB L C 2 DJ C 2 2 DJ C 2 1 GC 1 8 1 0 6 0 DJ C 2 1 DJ C 2 1 DJ C 2 1 DJ C 2 1 GFB2066 GFB2032 1 WBBC2WBBC2 KMA1 WBBC2WBBC2 KMA1 FRAME CROSS SECTION AT FRAME LINE(S) 5 C CL D CL E CL F CL G CL BL B BL J 156'-1 5/8" 0.5000:12 19 ' - 6 " 26 ' - 0 " 8 7 3 2 6 29 @ 5'-0" 5 4 3 @ 5 ' - 0 " 3 2 156'-0" 26'-0"26'-0"26'-0"26'-0"26'-0"26'-0" 07/12/2022 Frame Member Schedule Part Mem Width Thick WebThk.Depth1 Depth2 Approx.Lgth Approx.Weight CX015 1 10.0000 .3750 .1644 1'-6"1'-6"24'-10 15/16"1006# RBX033 2-3 8.0000 .2500 .1875 3'-0"3'-0"20'-7 1/4"885# CX015 4 10.0000 .3750 .1644 1'-6"1'-6"24'-10 15/16"1006# Id Qty Grade Bolt Bolt Plate Rows Rows Tension Washer PartNo Dia.Length Thick.Out In Bolt A 16 F1852 3/4"2 3/4"3/4"4 4 Yes Yes 0097391 B 2 F1852 3/4"3"3/8"Yes Yes 0097392 Bolt Connection & Plate Schedule 1 8" 2 1'-0 1/2" Dimension Key Frame Clearances Horiz. Clearance between members 1(CX015) and 4(CX015): 20'-8" Vert. Clearance at member 1(CX015): 21'-8 1/16" Vert. Clearance at member 4(CX015): 21'-8 1/16" Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) Shape Name = 156 x100x26(HS) Wall 4, Frame 3 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\13 CedarpointFinalR5.vpc1_PORTAL FRAME ELEVATION ALONG J.dwg 7/8/2022 15:05:46SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. PORTAL FRAME ELEVATION ALONG J 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 13NTS 1. USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS, UNLESS NOTED OTHERWISE. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME SIDE OF THE WEB AS THE HILLSIDE WASHER. BB PERMIT SET- For Building Dept. Approval AA CX 0 1 5 RBX033 CX 0 1 5 HFB3060HFB3060 PORTAL FRAME ELEVATION ALONG J 43 2 24 ' - 1 0 1 5 / 1 6 " 123'-8"1 25'-0" 07/12/2022 Frame Member Schedule Part Mem Width Thick WebThk.Depth1 Depth2 Approx.Lgth Approx.Weight CX011 1 5.0000 .1345 .1345 10"10"16'-2 3/4"184# RBX027 2 5.0000 .1345 .1345 1'-0"1'-0"13'-8 1/8"169# RBX028 3 5.0000 .1345 .1345 1'-0"1'-0"1 1/2"1# Id Qty Grade Bolt Bolt Plate Rows Rows Tension Washer PartNo Dia.Length Thick.Out In Bolt A 2 F1852 3/4"2"3/8"1 1 Yes Yes 0097388 B 3 F1852 3/4"2"3/8"--Yes Yes 0097388 Bolt Connection & Plate Schedule 1 8 1/2" 2 4'-6" 3 2'-2 1/2" 4 1'-6 3/8" 5 2 @ 4'-2 7/8" 6 2 @ 5'-0" 7 2'-4" Dimension Key Frame Clearances Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) Shape Name = 15x50'-6"x19'-6"(HS) Wall 2, Frame 1 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\14 CedarpointFinalR5.vpc1_FRAME CROSS SECTION AT FRAME LINE(S) 3 (b) PERMIT.dwg 7/11/2022 15:42:43SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. FRAME CROSS SECTION AT FRAME LINE(S) 3 (b) 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 14NTS 1. USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS, UNLESS NOTED OTHERWISE. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME SIDE OF THE WEB AS THE HILLSIDE WASHER. PERMIT SET- For Building Dept. Approval 102'-0" B A RBX028 RBX027 CX 0 1 1 GF B 2 0 3 3 GF B 2 0 3 3 FB L C 2 FB L C 2 GFB2000 1 WBBC2WBBC2 KMA1 FRAME CROSS SECTION AT FRAME LINE(S) 3 BL B BL A 15'-0 1/8" 0.5000:12 19 ' - 6 " 18 ' - 1 0 1 / 2 " 7 6 7' - 2 " 5 5'-0"4 3 2 5' - 0 " 7' - 2 " 15'-0" 07/12/2022 Frame Member Schedule Part Mem Width Thick WebThk.Depth1 Depth2 Approx.Lgth Approx.Weight CX012 1 5.0000 .1345 .1345 10"10"16'-2 3/4"179# RBX029 2 5.0000 .1875 .1345 1'-0"1'-0"13'-8 1/8"193# RBX030 3 5.0000 .1875 .1345 1'-0"1'-0"1 1/2"1# Id Qty Grade Bolt Bolt Plate Rows Rows Tension Washer PartNo Dia.Length Thick.Out In Bolt A 2 F1852 3/4"2"3/8"1 1 Yes Yes 0097388 B 3 F1852 3/4"2"3/8"--Yes Yes 0097388 Bolt Connection & Plate Schedule 1 8 1/2" 2 4'-6" 3 2'-2 1/2" 4 1'-6 3/8" 5 2 @ 4'-2 7/8" 6 4'-0" 7 3'-2" 8 2 @ 5'-0" 9 2'-4" Dimension Key Frame Clearances Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) Shape Name = 15x50'-6"x19'-6"(HS) Wall 2, Frame 2 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\15 CedarpointFinalR5.vpc1_FRAME CROSS SECTION AT FRAME LINE(S) 2 (b) PERMIT.dwg 7/11/2022 15:44:19SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. FRAME CROSS SECTION AT FRAME LINE(S) 2 (b) 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 15NTS 1. USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS, UNLESS NOTED OTHERWISE. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME SIDE OF THE WEB AS THE HILLSIDE WASHER. PERMIT SET- For Building Dept. Approval 102'-0" B A RBX030 RBX029 CX 0 1 2 (2 ) G F B 2 0 3 3 GF B 2 0 3 3 FB L C 2 FB L C 2 ES B S B (2)GFB2000 GFB2000 1 WBBC2WBBC2 KMA1 WBBC2WBBC2 KMA1 FRAME CROSS SECTION AT FRAME LINE(S) 2 BL B BL A 15'-0 1/8" 0.5000:12 19 ' - 6 " 18 ' - 1 0 1 / 2 " 9 8 7 6 5 5'-0"4 3 2 5' - 0 " 7' - 2 " 15'-0" 07/12/2022 Frame Member Schedule Part Mem Width Thick WebThk.Depth1 Depth2 Approx.Lgth Approx.Weight CX013 1 5.0000 .1345 .1345 10"10"16'-2 3/4"174# RBX031 2 5.0000 .1345 .1345 1'-0"1'-0"13'-8 1/8"164# RBX028 3 5.0000 .1345 .1345 1'-0"1'-0"1 1/2"1# Id Qty Grade Bolt Bolt Plate Rows Rows Tension Washer PartNo Dia.Length Thick.Out In Bolt A 2 F1852 3/4"2"3/8"1 1 Yes Yes 0097388 B 3 F1852 3/4"2"3/8"--Yes Yes 0097388 Bolt Connection & Plate Schedule 1 8 1/2" 2 4'-6" 3 2'-2 1/2" 4 1'-6 3/8" 5 2 @ 4'-2 7/8" 6 4'-0" 7 3'-2" 8 2 @ 5'-0" 9 2'-4" Dimension Key Frame Clearances Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) Shape Name = 15x50'-6"x19'-6"(HS) Wall 2, Frame 3 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\16 CedarpointFinalR5.vpc1_FRAME CROSS SECTION AT FRAME LINE(S) 1 (b) PERMIT.dwg 7/11/2022 15:45:34SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. FRAME CROSS SECTION AT FRAME LINE(S) 1 (b) 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 16NTS 1. USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS, UNLESS NOTED OTHERWISE. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME SIDE OF THE WEB AS THE HILLSIDE WASHER. PERMIT SET- For Building Dept. Approval 102'-0" B A RBX028 RBX031 CX 0 1 3 GF B 2 0 3 3 GF B 2 0 3 3 FB L C 2 FB L C 2 DJ C 2 1 DJ C 2 1 GFB2000 1 WBBC2WBBC2 KMA1 FRAME CROSS SECTION AT FRAME LINE(S) 1 BL B BL A 15'-0 1/8" 0.5000:12 19 ' - 6 " 18 ' - 1 0 1 / 2 " 9 8 7 6 5 5'-0"4 3 2 5' - 0 " 7' - 2 " 15'-0" 07/12/2022 VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D PRIMARY BRACING SED'S Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 17 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 1. USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS, UNLESS NOTED OTHERWISE. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME SIDE OF THE WEB AS THE HILLSIDE WASHER. 8:44:447/5/2022 SEDSheet 07/12/2022 VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D MRD50 Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 18 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 14:18:417/7/2022 SEDSheet 07/12/2022 1 RKC15 (+) SSR Fixed Clip Location Part Mark Key 1 6" Dimension Key Secondary Part Schedule Mark Part Thick.Depth Lap Detail E1 00107HS2411415B00 0.0730 7"BR09W2, BR09Y2 E2 00108ES2411411B00 0.1130 8 1/2"RS12PF, RS12PE E3 07H2411415DDB00 0.0730 7"BR09W2, BR09Y2 E4 08E2411411DDB00 0.1130 8 1/2"RS12PE E5 00208ES2411411B00 0.1130 8 1/2"RS12PH, RS12PA E6 00308ES2411414B00 0.0790 8 1/2"RS12PH, RS12PA E7 00408ES2505414B00 0.0790 8 1/2"RS12PH, RS12PA P1 08Z2811412B5B0 0.0980 8 1/2"3'-10 1/2"RS02T1, RS01T1 P2 08Z301141544B0 0.0730 8 1/2"2'-10 1/2"RS01T1 P3 08Z301141244B0 0.0980 8 1/2"2'-10 1/2"RS01T1 P4 08Z2811413B5B0 0.0880 8 1/2"3'-10 1/2"RS02T1, RS01T1 P5 08Z2905413B5B0 0.0880 8 1/2"3'-10 1/2"RS02T1, RS01T1 Id Qty Mark No Spacing 1 19 PBA0108 1'-4 7/8" 2 236 CPBB050108(Typ.)5'-0" 3 8 CPBB050000 4'-10 3/8" 4 19 PBA0502 4'-10 3/8" 5 4 CPBRA011102 1'-6 3/8" 6 4 CPBB040408 4'-2 7/8" 7 9 PBA0406 4'-2 7/8" See SED: BR09K5, BR09JG, BR09RY, BR09RZ, BR09JR BR09JH, BR09K2, BR09PK, BR09PH Secondary Bracing Schedule Shape Name = 156 x100x26(HS), Shape = 15x50'-6"x19'-6"(HS) JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\19 CedarpointFinalR5.vpc1_ROOF SECONDARY PLAN.dwg 7/11/2022 07:26:51SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. ROOF SECONDARY PLAN 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 19NTS 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. PERMIT SET- For Building Dept. Approval BL 54 BL 32 BL 1 BLJ G F E D C BLB BLA ROOF SECONDARY PLAN 7 6 2 7 6 2 77 6 2 7 6 2 5 11 2R1B22R1B1 ++ ++ ++ 4 3 1 4 3 1 4 1 4 3 1 4 3 1 4 1 4 3 1 4 3 1 4 1 4 3 1 4 3 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1R1B41R1B3 1R1B21R1B1 E7 P5(Typ.) E6 P4(Typ.) 1 24'-6"25'-0" 50'-6" 15 ' - 0 " E5 P1(Typ.) E1 E4 P3 P3 P3 P2(Typ.) E3 E4 P2(Typ.) E3 E2 P1(Typ.) E1 124'-6"25'-0"25'-0"24'-6" 100'-0" 15 6 ' - 0 " 1 1 07/12/2022 VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D ROOF SECONDARY SED'S (a) Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 20 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. 8:44:467/5/2022 SEDSheet 07/12/2022 VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D ROOF SECONDARY SED'S (b) Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 21 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. 8:44:487/5/2022 SEDSheet 07/12/2022 1 JTG1 2 PG1 3 J2 4 J3 5 G2 6 G4 7 J4 8 J5 9 G6 10 G8 11 J7 12 J8 13 J9 14 J10 15 J11 16 GFA106 17 GFA306 18 GFA206 19 GFA300 Part Mark Key 1 4'-0" 2 3'-2" 3 2'-4" 4 2" 5 2'-6" 6 3'-6" 7 1'-2" Dimension Key Secondary Part Schedule Mark Part Thick.Depth Lap Detail G1 08C0702417DG00 0.0600 8 1/2"WSR001, WS20F2 G10 08Z2505415GG00 0.0730 8 1/2"BRR052, WS01K2 G11 00308ZS060071700 0.0600 8 1/2"WS01K2, BRR052, WS04E2 G12 08Z2505417GG00 0.0600 8 1/2"BRR052, WS01K2 G13 08C0611417GG00 0.0600 8 1/2"BRR052, WS01K2, WS20F2 G14 08Z0611417GG00 0.0600 8 1/2"BRR052, WS01K2, WS20F2 G15 08C2505412GG00 0.0980 8 1/2"BRR052, WS01K2 G16 08Z2505414GG00 0.0790 8 1/2"BRR052, WS01K2 G17 08Z2505416GG00 0.0680 8 1/2"BRR052, WS01K2 G18 00408ZS230971700 0.0600 8 1/2"WSR001, WSR004, BRR052, WS01K2 G19 00108CS230811500 0.0730 8 1/2"WSR001, WSR004, BRR052, WS01K2 G2 08C0111417GG00 0.0600 8 1/2"WSR001, BRR052, WS01K2, WS20F2 G20 00508ZS230531300 0.0880 8 1/2"WSR001, WSR004, BRR052, WS01K2 G21 00608ZS230251300 0.0880 8 1/2"WSR001, WSR004, BRR052, WS01K2 G22 00708ZS221171500 0.0730 8 1/2"WSR001, WSR004, BRR052, WS01K2 G3 00108ZS040711700 0.0600 8 1/2"WSR001, WS20F2, BRR052 G4 08Z0111417GG00 0.0600 8 1/2"WSR001, BRR052, WS01K2, WS20F2 G5 00208ZS241101500 0.0730 8 1/2"WSR001, WS01K2, BRR052, WSR004 G6 08C0211417GG00 0.0600 8 1/2"WS20F2, BRR052, WS01K2 G7 08C0511417GG00 0.0600 8 1/2"WS20F2, BRR052, WS01K2 G8 08Z0211417GG00 0.0600 8 1/2"WS20F2, BRR052, WS01K2 G9 08Z0511417GG00 0.0600 8 1/2"WS20F2, BRR052, WS01K2 H1 00108JS1600017 0.0600 8 1/2"WS20F9 H2 00208JS0500017 0.0600 8 1/2"WS20F9 J1 00308JS1410217 0.0600 8 1/2"WS20FB, WS20F9, WS20F2, WS20B2, WS20B8 J10 01208JS0101117 0.0600 8 1/2"WS20B4, BRR052, WS20H2 J11 01308JS0111017 0.0600 8 1/2"WS20B4, BRR052, WS20H2 J2 00408JS0206417 0.0600 8 1/2"WS20FB, WS20F9, WS20B2, WS20H2 J3 00508JS0103117 0.0600 8 1/2"WS20B4, BRR052, WS20H2 J4 00608JS0105617 0.0600 8 1/2"WS20B4, BRR052, WS20H2 J5 00708JS0002617 0.0600 8 1/2"WS20B4, BRR052, WS20H2 J6 00808JS0203217 0.0600 8 1/2"WS20B4, BRR052, WS20H2 J7 00908JS0110417 0.0600 8 1/2"WS20B2, WS20H2 J8 01008JS0002717 0.0600 8 1/2"WS20B4, BRR052, WS20H2 J9 01108JS0010717 0.0600 8 1/2"WS20B4, BRR052, WS20H2 Framed Opening Locations Id Width Height Sill Ht.Frame To Dimen.Description FO1 5'-0"2'-0"15'-2"2 Jamb-L 6'-6"5020 Window FO FO2 5'-0"2'-0"15'-2"3 Jamb-L 2'-6"5020 Window FO FO3 5'-0"2'-0"15'-2"1 Jamb-L 3'-6"5020 Window FO FO4 5'-0"2'-0"15'-2"2 Jamb-L 17'-6"5020 Window FO FO5 5'-0"2'-0"15'-2"BL Jamb-L 18'-6"5020 Window FO FO6 5'-0"2'-0"15'-2"3 Jamb-L 13'-6"5020 Window FO FO7 5'-0"2'-0"15'-2"1 Jamb-L 14'-6"5020 Window FO FO8 5'-0"2'-0"15'-2"BL Jamb-L 7'-6"5020 Window FO Shape Name = 156 x100x26(HS), Wall = 1 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\22 CedarpointFinalR5.vpc1_SECONDARY ELEVATION AT 1 (a).dwg 7/12/2022 07:56:53SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. SECONDARY ELEVATION AT 1 (a) 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 22NTS 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. PERMIT SET- For Building Dept. Approval SECONDARY ELEVATION AT 1 FO8 FO7 FO6FO5FO4FO3FO2FO1 17 17 19 19 18 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 1616 1617 16 1W1B51W1B41W1B3 22 2 2 2 2 2 2 2 2 2 2 2 2 2222 22 11 1 1 1W1B2 22 2 2 2 2 2 2 2 2 2 2 2 2 2 2 22 22 11 1 1 1W1B1 2 22 2 2 2 2 2 2 2 2 22 22 22 11 1 1 1W1B0 2 2 2 2 2 2 2 2 2 2 222 22 11 1 1 C CL D CL E CL F CL G CL BL J BL B NBVP - MasonryNBVP - MasonryNBVP - MasonryNBVP - MasonryNBVP - Masonry 77 14 ' - 0 " 77 14 ' - 0 " 77 14 ' - 0 " 77 14 ' - 0 " 7'-6"5'-0"6'-0"5'-0"565'-0"6'-0"5'-0"6'-6"6'-6"5'-0"6'-0"5'-0"655'-0"6'-0"5'-0"7'-6" 7'-6"16'-0"5616'-0"6'-6"6'-6"16'-0"6516'-0"7'-6" 54 3 2@ 5 ' - 0 " 2 1 G22 G21 G20 G19 G18 G17(Typ.) G16 G15 G12 G10 G146 5 G13 15 14 11 11 3 J1 J1 3 H2H2 H1 G12 G10 10G9 G7 9 13 12 11 11 3 J1 J1 3 H2H2 H1 G11 G10 G910 9 G7 8 J6 7 J1 33 J1 H2H2 H1 G5 6G3 G1 5 4 3 J1 J1 3 H2H2 H1 26'-0"26'-0"26'-0"26'-0"26'-0"26'-0" 26 ' - 0 " 19 ' - 6 " 156'-0" 07/12/2022 1 PG1 Part Mark Key 2 GC5 3 JTG1 1 6" Dimension Key 2 4'-0" 3 3'-2" 4 2'-4" 5 8" Mark Secondary Part Schedule Part Thick.Depth Lap Detail G23 08Z2511417B100 0.0600 8 1/2"10 1/2"WSR001,BRR052,WS01G3 G24 08C2411416BD00 0.0680 8 1/2"WSR001,BRR052,WS01G2 G25 08C2411413DD00 0.0880 8 1/2"BRR052,WS01G2 G26 08Z26114171100 0.0600 8 1/2"10 1/2"BRR052,WS01G3 G27 08C2411416DD00 0.0680 8 1/2"BRR052,WS01G2 G28 00808ZS250441700 0.0600 8 1/2"WSR001,WS20F2 J12 01408JS0501617 0.0600 8 1/2"WS20F2,WS20B1,WS20B8 J13 01508JS0501617 0.0600 8 1/2"WS20B1,WS20B8 NBVP - Masonry NBVP - Masonry 100'-0" 19 ' - 6 " 1 24'-6"25'-0"25'-0"24'-6"1 5 BL 1 BL CLCL 2 CL 3 CL 4 CL 1W2B1 G23(Typ.) G24 1W2B2 G25 G26(Typ.) 1 2 J1 2 1 2 J1 3 1W2B3 G27 G26(Typ.) 3 1W2B4 G28 G24 G23(Typ.) 2 3 2@ 5 ' - 0 " 4 16'-0"8'-4"5 SECONDARY ELEVATION AT B VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D SECONDARY ELEVATION AT B (a) Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 23 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. Shape Name = 156 x100x26(HS), Wall = 2 8:44:517/5/2022 07/12/2022 1 JTG1 2 PG1 3 J2 4 J7 5 J10 6 J11 7 G2 8 G4 9 J9 10 G6 11 G8 12 J14 13 J16 14 J17 15 GFA206 16 GFA300 17 GFA106 18 GFA306 Part Mark Key 1 4'-0" 2 3'-2" 3 3'-10" 4 2'-6" 5 3'-6" 6 1'-2" Dimension Key Secondary Part Schedule Mark Part Thick.Depth Lap Detail G10 08Z2505415GG00 0.0730 8 1/2"BRR052, WS01K2 G12 08Z2505417GG00 0.0600 8 1/2"BRR052, WS01K2 G13 08C0611417GG00 0.0600 8 1/2"WS20F2, BRR052, WS01K2 G14 08Z0611417GG00 0.0600 8 1/2"WS20F2, BRR052, WS01K2 G15 08C2505412GG00 0.0980 8 1/2"BRR052, WS01K2 G16 08Z2505414GG00 0.0790 8 1/2"BRR052, WS01K2 G17 08Z2505416GG00 0.0680 8 1/2"BRR052, WS01K2 G18 00408ZS230971700 0.0600 8 1/2"WSR001, WS01K2, BRR052, WSR004 G19 00108CS230811500 0.0730 8 1/2"WSR001, WS01K2, BRR052, WSR004 G2 08C0111417GG00 0.0600 8 1/2"BRR052, WS01K2, WS20F2 G20 00508ZS230531300 0.0880 8 1/2"WSR001, WS01K2, BRR052, WSR004 G21 00608ZS230251300 0.0880 8 1/2"WSR001, WS01K2, BRR052, WSR004 G22 00708ZS221171500 0.0730 8 1/2"WSR001, WS01K2, BRR052, WSR004 G29 00908ZS060441700 0.0600 8 1/2"WS04E2, BRR052, WS01K2 G30 01008ZS050341700 0.0600 8 1/2"WSR001, BRR052, WSR004, WS20F2 G31 00208CS050101700 0.0600 8 1/2"WSR001, BRR052, WSR004, WS20F2 G32 01108ZS040911700 0.0600 8 1/2"WSR001, BRR052, WSR004, WS20F2 G33 01208ZS221121500 0.0730 8 1/2"WSR001, WSR004, BRR052, WS01K2 G4 08Z0111417GG00 0.0600 8 1/2"BRR052, WS01K2, WS20F2 G6 08C0211417GG00 0.0600 8 1/2"BRR052, WS01K2, WS20F2 G7 08C0511417GG00 0.0600 8 1/2"WS20F2, BRR052, WS01K2 G8 08Z0211417GG00 0.0600 8 1/2"WS20F2, BRR052, WS01K2 G9 08Z0511417GG00 0.0600 8 1/2"WS20F2, BRR052, WS01K2 H1 00108JS1600017 0.0600 8 1/2"WS20F9 H2 00208JS0500017 0.0600 8 1/2"WS20F9 J1 00308JS1410217 0.0600 8 1/2"WS20FB, WS20F9, WS20F2, WS20B2, WS20B8 J10 01208JS0101117 0.0600 8 1/2"WS20B4, BRR052, WS20H2 J11 01308JS0111017 0.0600 8 1/2"WS20B4, BRR052, WS20H2 J14 01608JS0105017 0.0600 8 1/2"WS20B4, BRR052, WS20H2 J15 01708JS1410217 0.0600 8 1/2"WS20FB, WS20F9, WS20F2, WS20B2, WS20B8 J16 01808JS0003717 0.0600 8 1/2"WS20B4, BRR052, WS20H2 J17 01908JS0102317 0.0600 8 1/2"WS20B4, BRR052, WS20H2 J2 00408JS0206417 0.0600 8 1/2"WS20FB, WS20F9, WS20B2, WS20H2 J7 00908JS0110417 0.0600 8 1/2"WS20B2, WS20H2 J9 01108JS0010717 0.0600 8 1/2"WS20B4, BRR052, WS20H2 Framed Opening Locations Id Width Height Sill Ht.Frame To Dimen.Description FO1 5'-0"2'-0"15'-2"3 Jamb-L 3'-6"5020 Window FO FO2 5'-0"2'-0"15'-2"5 Jamb-L 2'-6"5020 Window FO FO3 5'-0"2'-0"15'-2"4 Jamb-L 6'-6"5020 Window FO FO4 5'-0"2'-0"15'-2"2 Jamb-L 7'-6"5020 Window FO FO5 5'-0"2'-0"15'-2"5 Jamb-L 13'-6"5020 Window FO FO6 5'-0"2'-0"15'-2"2 Jamb-L 18'-6"5020 Window FO FO7 5'-0"2'-0"15'-2"4 Jamb-L 17'-6"5020 Window FO FO8 5'-0"2'-0"15'-2"3 Jamb-L 14'-6"5020 Window FO Shape Name = 156 x100x26(HS), Wall = 3 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\24 CedarpointFinalR5.vpc1_SECONDARY ELEVATION AT 5.dwg 7/11/2022 08:10:30SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. SECONDARY ELEVATION AT 5 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 24NTS 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. PERMIT SET- For Building Dept. Approval SECONDARY ELEVATION AT 5 FO8 FO7FO6 FO5FO4FO3FO2FO1 18 16 16 15 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 18 1718 1716 1716 15 1W3B5 2 2 2 2 2 2 2 2 2 2 22 22 22 11 11 1 1W3B4 2 2 2 2 2 2 2 2 2 2 2 2 2 22 22 11 1 1 1W3B3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 22 22 11 1 1 1W3B2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2222 22 11 1 1 1W3B11W3B0 C CL D CL E CL F CL G CL BL B BL J NBVP - MasonryNBVP - MasonryNBVP - MasonryNBVP - MasonryNBVP - Masonry 66 14 ' - 0 " 66 14 ' - 0 " 66 14 ' - 0 " 66 14 ' - 0 " 7'-6"5'-0"6'-0"5'-0"455'-0"6'-0"5'-0"6'-6"6'-6"5'-0"6'-0"5'-0"545'-0"6'-0"5'-0"7'-6" 7'-6"16'-0"4516'-0"6'-6"6'-6"16'-0"5416'-0"7'-6" 3 2@ 2 ' - 6 " 2@ 5 ' - 0 " 2 1 G33 G328 G317 G30 14 13 J1 5 J1 3 3 H2 H2 H1 G29 G10 11G9 G7 10 12 4 3 J1 J1 3 H2H2 H1 G12 G10 G911 10 G7 9 4 4 3 J1 J1 3 H2H2 H1 G12 G10 8G14 G13 7 6 5 4 4 3 J1 J1 3 H2H2 H1 G17(Typ.) G16 G15 G22 G21 G20 G19 G18 26'-0"26'-0"26'-0"26'-0"26'-0"26'-0" 19 ' - 6 " 26 ' - 0 " 156'-0" NBVP - MasonryNBVP - Masonry 07/12/2022 1 6" 2 4'-0" 3 3'-2" 4 3'-10" Dimension Key Secondary Part Schedule Mark Part Thick.Depth Lap Detail G23 08Z2511417B100 0.0600 8 1/2"10 1/2"WSR001, BRR052, WS01G3 G24 08C2411416BD00 0.0680 8 1/2"WSR001, BRR052, WS01G2 G25 08C2411413DD00 0.0880 8 1/2"BRR052, WS01G2 G26 08Z26114171100 0.0600 8 1/2"10 1/2"BRR052, WS01G3 Shape Name = 156 x100x26(HS), Wall = 4 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\25 CedarpointFinalR5.vpc1_SECONDARY ELEVATION AT J.dwg 7/11/2022 08:16:45SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. SECONDARY ELEVATION AT J 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 25NTS 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. PERMIT SET- For Building Dept. Approval SECONDARY ELEVATION AT J 1W4B41W4B31W4B21W4B1 CL 4 CL 3 CL 2 CLCL BL 5 BL 1 NBVP - Masonry 4 3@ 5 ' - 0 " 3 2 G24 G23(Typ.) G26(Typ.) G25 G26(Typ.) G25G24 G23(Typ.) 124'-6"25'-0"25'-0"24'-6"1 26 ' - 0 " 100'-0" NBVP - Masonry NBVP - Masonry NBVP - Masonry 07/12/2022 1 JTG1 2 PG1 3 G35 4 G41 5 GFA200 6 GFA106 Part Mark Key 1 2'-10" 2 1'-8" Dimension Key Secondary Part Schedule Mark Part Thick.Depth Lap Detail G34 08C0308417GL00 0.0600 8 1/2"WSR001, WS20F2, BRR052 G35 08C0108417GL00 0.0600 8 1/2"WSR001, BRR052, WS20F2 G36 08C0508417GL00 0.0600 8 1/2"WSR001, WS20F2, BRR052 G37 08C0311417GG00 0.0600 8 1/2"WSR001, BRR052, WS20F2 G38 08C2306417LS00 0.0600 8 1/2"WSR001, BRR052, WSR004 G39 08C2309417GS00 0.0600 8 1/2"WSR001, WSR004, BRR052 G40 08Z0308417GL00 0.0600 8 1/2"WSR001, WS20F2, BRR052 G41 08Z0108417GL00 0.0600 8 1/2"WSR001, BRR052, WS20F2 G42 08Z0508417GL00 0.0600 8 1/2"WSR001, WS20F2, BRR052 G43 08Z0311417GG00 0.0600 8 1/2"WSR001, BRR052, WS20F2 G44 08Z2306417LS00 0.0600 8 1/2"WSR001, BRR052, WSR004 G45 08Z2309417GS00 0.0600 8 1/2"WSR001, WSR004, BRR052 G46 08Z2405417GG00 0.0600 8 1/2"WSR001, BRR052 H1 00108JS1600017 0.0600 8 1/2"WS20F9 J18 02008JS1708217 0.0600 8 1/2"WS20F9, WS20F2, WS20B2, WS20B8 Shape Name = 156 x100x26(HS), Wall = 1 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\26 CedarpointFinalR5.vpc1_SECONDARY ELEVATION AT D.dwg 7/11/2022 08:26:17SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. SECONDARY ELEVATION AT D 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 26NTS 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. PERMIT SET- For Building Dept. Approval SECONDARY ELEVATION AT D 666 66 66655 6 6655 6 6655 1P1B0 2 2 2 2 2 2 2 2 1111 22 22 1111 1111 CL BL 5 BL 1 NBVP - Masonry 14 ' - 0 " 14 ' - 0 " 29'-6"16'-0"7'-0"16'-0"31'-6" 2 2@ 5 ' - 0 " 1 7' - 2 " G46 G46 G45G45 G44 G45G43G424G40 G45G44G43G424G40 G39G38G37G363G34 J1 8 J1 8 J1 8 J1 8 H1 H1 21 ' - 8 " 25'-0"25'-0"25'-0"25'-0" 21 ' - 8 " 100'-0" NBVP - Masonry NBVP - Masonry 07/12/2022 1 JTG1 2 PG1 3 J21 4 J22 5 G47(Typ.) 6 G48 7 GFA306 8 GFA200 9 GFA206 Part Mark Key 1 4'-0" 2 3'-2" 3 4'-6" 4 2'-2 1/2" 5 2'-7" 6 1'-5" Dimension Key Secondary Part Schedule Mark Part Thick.Depth Lap Detail G47 JCP051074 0.0600 8 1/2"WSR001, WS20F2, BRR052, WSR004 G48 JCP051120 0.0600 8 1/2"WSR001, BRR052, WSR004, WS20F2 G49 01308ZS130301700 0.0600 8 1/2"WSR001, BRR052, WSR004 H3 02108JS1100017 0.0600 8 1/2"WS20F9 J19 02208JS1404217 0.0600 8 1/2"WS20F9, WS20F2, WS20B2, WS20B8 J20 02308JS1404217 0.0600 8 1/2"WS20F9, WS20F2, WS20B2, WS20B8 J21 02408JS0002217 0.0600 8 1/2"WS20B4, BRR052, WS20H2 J22 02508JS0007617 0.0600 8 1/2"WS20B4, BRR052, WS20H2 Shape Name = 15x50'-6"x19'-6"(HS), Wall = 1 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\27 CedarpointFinalR5.vpc1_SECONDARY ELEVATION AT 1 (b).dwg 7/11/2022 08:24:07SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. SECONDARY ELEVATION AT 1 (b) 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 27NTS 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. PERMIT SET- For Building Dept. Approval SECONDARY ELEVATION AT 1 9 87 87 7 2W1B0 22 2 2 2 2 22 11 11 1 BL B BL A NBVP - MasonryNBVP - Masonry 14 ' - 0 " 611'-0"5 4 3 5' - 0 " 2 1 G49 6 6 5 4 3 J2 0 J1 9 H3 19 ' - 6 " 18 ' - 1 0 1 / 2 " 15'-0" 07/12/2022 1 6" 2 4'-6" 3 2'-2 1/2" Dimension Key Secondary Part Schedule Mark Part Thick.Depth Lap Detail G23 08Z2511417B100 0.0600 8 1/2"10 1/2"WSR001, BRR052, WS01G3 G50 08C2505413BD00 0.0880 8 1/2"WSR001, BRR052, WS01G2 G51 08Z2605417B100 0.0600 8 1/2"10 1/2"WSR001, BRR052, WS01G3 G52 08C2411413BD00 0.0880 8 1/2"WSR001, BRR052, WS01G2 Shape Name = 15x50'-6"x19'-6"(HS), Wall = 2 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\28 CedarpointFinalR5.vpc1_SECONDARY ELEVATION AT A.dwg 7/11/2022 08:31:06SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. SECONDARY ELEVATION AT A 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 28NTS 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. PERMIT SET- For Building Dept. Approval SECONDARY ELEVATION AT A 2W2B22W2B1 CL 2 CLCL BL 1 BL 3 NBVP - Masonry 3 2 5' - 0 " 7' - 2 " G23(Typ.) G52 G51(Typ.) G50 124'-6"25'-0"1 18 ' - 1 0 1 / 2 " 50'-6" NBVP - Masonry 07/12/2022 1 GFA206 Part Mark Key 1 4'-0" 2 3'-2" 3 4'-6" 4 2'-10" Dimension Key Secondary Part Schedule Mark Part Thick.Depth Lap Detail G49 01308ZS130301700 0.0600 8 1/2"WSR001, BRR052, WSR004 G53 00308CS130301700 0.0600 8 1/2"WSR001, BRR052, WSR004 Shape Name = 15x50'-6"x19'-6"(HS), Wall = 3 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\29 CedarpointFinalR5.vpc1_SECONDARY ELEVATION AT 3.dwg 7/11/2022 08:40:02SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. SECONDARY ELEVATION AT 3 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 29NTS 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. PERMIT SET- For Building Dept. Approval SECONDARY ELEVATION AT 3 1 1 1 1 2W3B0 BL A BL B NBVP - Masonry 4 3 5' - 0 " 2 1 G53 G49(Typ.) 18 ' - 1 0 1 / 2 " 19 ' - 6 " 15'-0" 07/12/2022 1 JTG1 2 VCC05403100 3 PG1 4 J25 5 J26 6 G55 7 G54 Part Mark Key 1 4'-0" 2 3'-2" 3 4'-6" 4 2'-2 1/2" 5 3'-6" Dimension Key Secondary Part Schedule Mark Part Thick.Depth Lap Detail G54 08Z0206017GP00 0.0600 8 1/2"WSR001, WS20F2 G55 08Z0302417DG00 0.0600 8 1/2"WSR001, WS20F2 G56 08Z1403017DP00 0.0600 8 1/2"WSR001 H4 02608JS0800017 0.0600 8 1/2"WS20F9 J23 02708JS0910217 0.0600 8 1/2"WS20F9, WS20F2, WS20B2, WS20B8 J24 02808JS0310417 0.0600 8 1/2"WS20B2, WS20H2 J25 02908JS0200217 0.0600 8 1/2"WS20H2 J26 03008JS0204217 0.0600 8 1/2"WS20H2 Shape Name = 15x50'-6"x19'-6"(HS), Wall = 1 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\30 CedarpointFinalR5.vpc1_WALL SECONDARY ELEVATION PARTITION OR MISC. 1.dwg 7/11/2022 08:48:41SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. WALL SECONDARY ELEVATION PARTITION OR MISC. 1 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 30NTS 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. PERMIT SET- For Building Dept. Approval WALL SECONDARY ELEVATION PARTITION OR MISC. 1 2P1B0 33 3 3 2 3 3 2 3 3 3 3 33 112 12 1 BL B BL A CMU Stem Wall 10 ' - 0 " 58'-0"5 4 3 5' - 0 " 2 1 G56 G56 67 7 6 5 4 J2 4 J2 4 J2 3 J2 3 H4 7 1 / 2 " 18 ' - 1 0 1 / 2 " 15'-0" 19 ' - 6 " 18 ' - 1 0 1 / 2 " 15'-0" 07/12/2022 VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D WALL SECONDARY SED'S (a) Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 31 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. 8:45:007/5/2022 SEDSheet 07/12/2022 VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D WALL SECONDARY SED'S (b) Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 32 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. 8:45:017/5/2022 SEDSheet 07/12/2022 Covering Schedule Id Qty Start Length Qty Stagger Length Type Gage OP Fin.Color #52 13 41'-2 7/8"13 46'-2 7/8"SSR 24 2 G TD #53 51 45'-4"51 45'-4"SSR 24 2 G TD #54 26 40'-4 1/8"25 35'-4 1/8"SSR 24 2 G TD #55 13 26'-2 3/4"12 31'-2 3/4"SSR 24 2 G TD Oper. Code:2=SQ, SQ Finish:G=Galvalume Color:TD=Standard Color Trim Schedule Id Parts Color Details T1 EA2R, FPRF1 Cool Ebony RC38N2 T2 MCC1 Cool Ebony RC38AJ T3 EA2L, FPRF1 Cool Dark Bronze RC38N2 T4 EA2R, FPRF1 Cool Dark Bronze RC38N2 Accessory Schedule Qty Color Description Detail 6 Cool Zinc Gray 3070 PR/LR Door Trim Kit (500/700 Series) 1 1'-0" Starter Panel (Cut Dim. = 1'-1") detailed for a UL90 rating Construction #113 or 113A - The roof panels on this project has been" Ice Damming Conditions Exist Dimension Key Shape Name = 156 x100x26(HS), Shape = 15x50'-6"x19'-6"(HS) JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\33 CedarpointFinalR5.vpc1_ROOF COVERING PLAN.dwg 7/11/2022 08:56:07SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. ROOF COVERING PLAN 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 33NTS 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. PERMIT SET- For Building Dept. Approval BL 54 BL 32 BL 1 BLJ G F E D C BLB BLA ROOF COVERING PLAN T4T3 T2T2 T1 31 ' - 2 3 / 4 " 26 ' - 2 3 / 4 " 35 ' - 4 1 / 8 " 40 ' - 4 1 / 8 " 45 ' - 4 " 45 ' - 4 " 45 ' - 4 " 45 ' - 4 " 46 ' - 2 7 / 8 " 41 ' - 2 7 / 8 " 50'-6" 15 ' - 0 " (25)#55 (51)#54 (51)#53 (51)#53 1 (26)#52 1 100'-0" 15 6 ' - 0 " 07/12/2022 Liner/Soffit Schedule Id Qty Type Length Gage OP Finish Color Direction Cut #56 34 PR 19'-8 1/8"26 1 K GG Left to Right #57 34 PR 15'-4"26 1 K GG Left to Right #58 34 PR 17'-7 7/8"26 1 K GG Left to Right #78 17 PR 15'-0 1/8"26 1 K GG Left to Right Oper. Code:1=SQ, SQ Finish:K=KXL (Kynar) Color:GG=Cool Granite Gray Liner Trim Schedule Id Parts Color Details T1 (10)LTA10 Match Roof Color WC61A7, WCV060 T2 (11)JT10 Match Roof Color WC61A8 T3 (4)JT10 Match Roof Color WC61A8 Fastener Schedule Part Description 0097584-112 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer Shape Name = 156 x100x26(HS), Shape = 15x50'-6"x19'-6"(HS) JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\34 CedarpointFinalR5.vpc1_ROOF LINER PLAN.dwg 7/11/2022 09:12:50SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. ROOF LINER PLAN 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 34NTS 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. PERMIT SET- For Building Dept. Approval BL 54 BL 32 BL 1 BLJ G F E D C BLB BLA (View from outside Building) ROOF LINER PLAN T3T3T3 50'-6" 15 ' - 0 " T2T2T2T2T2 T1 T1 (17)#78 (34)#58 (34)#57 (34)#56 100'-0" 15 6 ' - 0 " 07/12/2022 Covering Schedule Id Qty Type Start Length Gage OP Fin.Color Increment Direction #1 34 W 5'-5 1/2"26 F K GZ Left to Right #2 3 W 12'-4 1/2"26 1 K GG 1 1/2"Left to Right #3 4 W 5'-8"26 1 K GG 1 1/2"Left to Right #4 3 W 13'-3"26 1 K GG 1 1/2"Left to Right #5 5 W 6'-6 1/2"26 1 K GG 1 1/2"Left to Right #6 5 W 14'-3"26 1 K GG 1 1/2"Left to Right #7 4 W 7'-9 1/2"26 1 K GG 1 1/2"Left to Right #8 3 W 15'-4 1/2"26 1 K GG 1 1/2"Left to Right #9 5 W 8'-8"26 1 K GG 1 1/2"Left to Right #10 20 W 16'-4 1/2"26 1 K GG 1 1/2"Left to Right Oper. Code:F=CR, SQ Oper. Code:1=SQ, SQ Finish:K=KXL (Kynar) Color:GZ=Cool Zinc Gray Color:GG=Cool Granite Gray Trim Schedule Id Parts Color Details T1 (0.5)BG2415 Cool Zinc Gray EN52A1, ENV003, RC00A1, WC01D9, WC04G1, WS27B2, WS27D2 T2 (0.4)BG2415 Cool Zinc Gray EN52A1, ENV003, RC00A1, WC01D9, WC04G1, WS27B2, WS27D2 T3 (0.9)BG2415 Cool Zinc Gray EN52A1, ENV003, RC00A1, WC01D9, WC04G1, WS27B2, WS27D2 T4 (4.0)BG2415 Cool Zinc Gray EN52A1, ENV003, RC00A1, WC01D9, WC04G1, WS27B2, WS27D2 T5 DFT10, JT07 Cool Ebony WC24A1 T6 DFT12, DFT05, HTS14, HTS03 Cool Ebony WC24A2 T7 DFT05, JT05 Cool Ebony WC24A1 T8 DFT05, HTS05 Cool Ebony WC24A2 T9 TDFH05 Cool Ebony WC24A4 T10 CT10 Cool Zinc Gray WC20A1 T11 CT20 Cool Granite Gray WC20A1 T12 CT05 Match Wall Color WC20A1 T13 (16)RFR10-130, (8)RKF20, (16)RSB10, (16)RSC10 Cool Ebony RC10A1, RC30A1, RS10L5 Fastener Schedule Part Description 0097581-116 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 0097581-112 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer Shape Name = 156 x100x26(HS), Wall = 1 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\35 CedarpointFinalR5.vpc1_COVERING ELEVATION AT 1 (a).dwg 7/11/2022 09:58:44SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. COVERING ELEVATION AT 1 (a) 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 35NTS 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. PERMIT SET- For Building Dept. Approval COVERING ELEVATION AT 1 T13 T1 2 T1 1 T1 0 T9T9T9T9T9T9T9T9 T8T8T8T8T8T8T8T8 T7T7T7T7 T7T7T7T7T7T7T7T7T7T7T7T7 T6T6T6T6 T5 T5 T5 T5 T5 T5 T5 T5 T5 T5 T5 T5 T5 T5 T5 T5 T4T3T2T2T1 18 ' - 9 " 18 ' - 7 1 / 2 " 18 ' - 6 " 18 ' - 4 1 / 2 " 18 ' - 3 " 18 ' - 1 1 / 2 " 18 ' - 0 " 17 ' - 1 0 1 / 2 " 17 ' - 9 " 17 ' - 7 1 / 2 " 17 ' - 6 " 17 ' - 4 1 / 2 " 17 ' - 3 " 17 ' - 1 1 / 2 " 17 ' - 0 " 16 ' - 1 0 1 / 2 " 16 ' - 9 " 16 ' - 7 1 / 2 " 16 ' - 6 " 16 ' - 4 1 / 2 " 9' - 2 " 9' - 0 1 / 2 " 8' - 1 1 " 8' - 9 1 / 2 " 8' - 8 " 15 ' - 7 1 / 2 " 15 ' - 6 " 15 ' - 4 1 / 2 " 8' - 2 " 8' - 0 1 / 2 " 7' - 1 1 " 7' - 9 1 / 2 " 14 ' - 9 " 14 ' - 7 1 / 2 " 14 ' - 6 " 14 ' - 4 1 / 2 " 14 ' - 3 " 7' - 0 1 / 2 " 6' - 1 1 " 6' - 9 1 / 2 " 6' - 8 " 6' - 6 1 / 2 " 13 ' - 6 " 13 ' - 4 1 / 2 " 13 ' - 3 " 6' - 0 1 / 2 " 5' - 1 1 " 5' - 9 1 / 2 " 5' - 8 " 12 ' - 7 1 / 2 " 12 ' - 6 " 12 ' - 4 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " BL J BL B NBVP - MasonryNBVP - MasonryNBVP - MasonryNBVP - MasonryNBVP - Masonry 59'-6"16'-0"6'-0"16'-0"13'-0"16'-0"6'-0"16'-0"7'-6" (20)#10(5)#9 (3)#8(4)#7 (5)#6(5)#5 (3)#4(4)#3 (3)#2 2' - 0 " (20)#1(3)#1(5)#1(3)#1(3)#1 26 ' - 0 " 19 ' - 6 " 156'-0" 07/12/2022 Id Covering Schedule Qty Type Start Length Gage OP Fin.Color Direction #21 32 W 5'-5 1/2"26 F K GZ Left to Right #22 17 W 12'-7 1/2"26 1 K GG Left to Right #23 15 W 12'-7"26 1 K GG Left to Right #24 2 W 12'-4"26 1 K GG Left to Right Oper. Code:F=CR,SQ Oper. Code:1=SQ,SQ Finish:K=KXL (Kynar) Color:GZ=Cool Zinc Gray Color:GG=Cool Granite Gray Id Trim Schedule Parts Color Details T1 (4.4)BG2415 Cool Zinc Gray EN52A1,ENV003,RC00A1,WC01D9,WC04G1,WS27B2,WS27D2 T2 (1.3)BG2415 Cool Zinc Gray EN52A1,ENV003,RC00A1,WC01D9,WC04G1,WS27B2,WS27D2 T3 (0.4)BG2415 Cool Zinc Gray EN52A1,ENV003,RC00A1,WC01D9,WC04G1,WS27B2,WS27D2 T4 DFT10,JT07 Cool Ebony WC24A1 T5 DFT10,HTS10 Cool Ebony WC24A2 T6 CT16 Cool Granite Gray WC20A1 T7 CT10 Match Wall Color WC20A1 T8 CT05 Match Wall Color WC20A1 T9 (2)EF20A,EF12A,(5)RFR10-130 Cool Ebony RC03A2,RC31A1,RCV536,WC04G1,WC11F1 T10 ICF16 Cool Granite Gray WC21A1 T11 ICF05 Match Wall Color WC21A1 T12 ICF10 Match Wall Color WC21A1 Part Fastener Schedule Description 0097581-116 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 0097581-112 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer NBVP - Masonry NBVP - Masonry 100'-0" 19 ' - 6 " 5 BL 1 BL (22)#21 (10)#21 2' - 0 " (17)#22 (5)#23 (2)#24 (10)#23 T1 T2 T3 T4 T4 T5 T6 T7 T8 T9 T1 0 T1 1 T1 2 66'-0"8'-4"25'-8" COVERING ELEVATION AT B VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D COVERING ELEVATION AT B (a) Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 36 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. Shape Name = 156 x100x26(HS), Wall = 2 8:45:087/5/2022 07/12/2022 Covering Schedule Id Qty Type Start Length Gage OP Fin.Color Increment Direction #30 34 W 5'-5 1/2"26 F K GZ Left to Right #31 20 W 18'-9"26 1 K GG -1 1/2"Left to Right #32 5 W 9'-2"26 1 K GG -1 1/2"Left to Right #33 3 W 15'-7 1/2"26 1 K GG -1 1/2"Left to Right #34 4 W 8'-2"26 1 K GG -1 1/2"Left to Right #35 5 W 14'-9"26 1 K GG -1 1/2"Left to Right #36 5 W 7'-0 1/2"26 1 K GG -1 1/2"Left to Right #37 3 W 13'-6"26 1 K GG -1 1/2"Left to Right #38 4 W 6'-0 1/2"26 1 K GG -1 1/2"Left to Right #39 3 W 12'-7 1/2"26 1 K GG -1 1/2"Left to Right Oper. Code:F=CR, SQ Oper. Code:1=SQ, SQ Finish:K=KXL (Kynar) Color:GZ=Cool Zinc Gray Color:GG=Cool Granite Gray Trim Schedule Id Parts Color Details T1 (4.0)BG2415 Cool Zinc Gray EN52A1, ENV003, RC00A1, WC01D9, WC04G1, WS27B2, WS27D2 T2 (0.4)BG2415 Cool Zinc Gray EN52A1, ENV003, RC00A1, WC01D9, WC04G1, WS27B2, WS27D2 T3 (0.9)BG2415 Cool Zinc Gray EN52A1, ENV003, RC00A1, WC01D9, WC04G1, WS27B2, WS27D2 T4 (0.5)BG2415 Cool Zinc Gray EN52A1, ENV003, RC00A1, WC01D9, WC04G1, WS27B2, WS27D2 T5 DFT10, JT07 Cool Ebony WC24A1 T6 DFT12, DFT05, HTS14, HTS03 Cool Ebony WC24A2 T7 DFT05, JT05 Cool Ebony WC24A1 T8 DFT05, HTS05 Cool Ebony WC24A2 T9 TDFH05 Cool Ebony WC24A4 T10 CT20 Cool Granite Gray WC20A1 T11 CT10 Match Wall Color WC20A1 T12 CT05 Match Wall Color WC20A1 T13 (16)RFR10-130, (8)RKF20, (16)RSB10, (16)RSC10 Cool Ebony RC10A1, RC30A1, RS10L5 Fastener Schedule Part Description 0097581-116 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 0097581-112 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer Shape Name = 156 x100x26(HS), Wall = 3 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\37 CedarpointFinalR5.vpc1_COVERING ELEVATION AT 5.dwg 7/11/2022 10:37:00SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. COVERING ELEVATION AT 5 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 37NTS 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. PERMIT SET- For Building Dept. Approval COVERING ELEVATION AT 5 T13 T1 2 T1 1 T1 0 T9 T9T9T9T9T9T9T9 T8 T8T8T8T8T8T8T8 T7T7 T7 T7 T7T7 T7 T7T7T7T7 T7T7T7T7T7 T6T6T6T6 T5 T5 T5 T5 T5 T5 T5 T5 T5 T5 T5 T5 T5 T5 T5 T5 T4T3T2T2T1 12 ' - 4 1 / 2 " 12 ' - 6 " 12 ' - 7 1 / 2 " 5' - 8 " 5' - 9 1 / 2 " 5' - 1 1 " 6' - 0 1 / 2 " 13 ' - 3 " 13 ' - 4 1 / 2 " 13 ' - 6 " 6' - 6 1 / 2 " 6' - 8 " 6' - 9 1 / 2 " 6' - 1 1 " 7' - 0 1 / 2 " 14 ' - 3 " 14 ' - 4 1 / 2 " 14 ' - 6 " 14 ' - 7 1 / 2 " 14 ' - 9 " 7' - 9 1 / 2 " 7' - 1 1 " 8' - 0 1 / 2 " 8' - 2 " 15 ' - 4 1 / 2 " 15 ' - 6 " 15 ' - 7 1 / 2 " 8' - 8 " 8' - 9 1 / 2 " 8' - 1 1 " 9' - 0 1 / 2 " 9' - 2 " 16 ' - 4 1 / 2 " 16 ' - 6 " 16 ' - 7 1 / 2 " 16 ' - 9 " 16 ' - 1 0 1 / 2 " 17 ' - 0 " 17 ' - 1 1 / 2 " 17 ' - 3 " 17 ' - 4 1 / 2 " 17 ' - 6 " 17 ' - 7 1 / 2 " 17 ' - 9 " 17 ' - 1 0 1 / 2 " 18 ' - 0 " 18 ' - 1 1 / 2 " 18 ' - 3 " 18 ' - 4 1 / 2 " 18 ' - 6 " 18 ' - 7 1 / 2 " 18 ' - 9 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " BL B BL J NBVP - MasonryNBVP - MasonryNBVP - MasonryNBVP - MasonryNBVP - Masonry 7'-6"16'-0"6'-0"16'-0"13'-0"16'-0"6'-0"16'-0"59'-6" (3)#39(4)#38(3)#37 (5)#36(5)#35 (4)#34(3)#33 (5)#32(20)#31 2' - 0 " (3)#30(3)#30(5)#30(3)#30(20)#30 19 ' - 6 " 26 ' - 0 " 156'-0" 07/12/2022 Id Covering Schedule Qty Type Start Length Gage OP Fin.Color Direction #50 34 W 5'-5 1/2"26 F K GZ Left to Right #51 34 W 19'-1 1/2"26 1 K GG Left to Right Oper. Code:F=CR,SQ Oper. Code:1=SQ,SQ Finish:K=KXL (Kynar) Color:GZ=Cool Zinc Gray Color:GG=Cool Granite Gray Id Trim Schedule Parts Color Details T1 (6.7)BG2415 Cool Zinc Gray EN52A1,ENV003,RC00A1,WC01D9,WC04G1,WS27B2,WS27D2 T2 (10)HSEP1,(10)RFR10-130,(5)RKF20 Cool Ebony RCV420,RCV421,RCV422,RCV423,RCV531 Part Fastener Schedule Description 0097581-116 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 0097581-112 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer NBVP - Masonry 100'-0" 26 ' - 0 " 1 BL 5 BL (34)#50 2' - 0 " (34)#51 T1 T2 COVERING ELEVATION AT J VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D COVERING ELEVATION AT J Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 38 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. Shape Name = 156 x100x26(HS), Wall = 4 8:45:117/5/2022 07/12/2022 Covering Schedule Id Qty Type Start Length Gage OP Fin.Color Direction #59 26 W 5'-5 1/2"26 F K GZ Left to Right #60 26 W 14'-7"26 1 K GG Left to Right #61 8 W 7'-8"26 1 K GG Left to Right Oper. Code:F=CR, SQ Oper. Code:1=SQ, SQ Finish:K=KXL (Kynar) Color:GZ=Cool Zinc Gray Color:GG=Cool Granite Gray Trim Schedule Id Parts Color Details T1 (2.1)BG2415 Cool Zinc Gray EN52A1, ENV003, RC00A1, WC01D9, WC04G1, WS27B2, WS27D2 T2 (0.5)BG2415 Cool Zinc Gray EN52A1, ENV003, RC00A1, WC01D9, WC04G1, WS27B2, WS27D2 T3 (2.0)BG2415 Cool Zinc Gray EN52A1, ENV003, RC00A1, WC01D9, WC04G1, WS27B2, WS27D2 T4 DFT10, JT07 Cool Ebony WC24A1 T5 DFT12, DFT05, HTS14, HTS03 Cool Ebony WC24A2 T6 HT07, CSF2112, CSD2112L Cool Zinc Gray WC64C7, WC80G1, WC80H2, WC80J2, WC80K2 T7 HT10, HT05, CSD2102L, (3)CSA2102R, (2)CSA1072R, CSA1042R, CSF1042 Cool Granite Gray WC64C7, WC80G1, WC80H2, WC80J2, WC80K2 T8 HT07, CSF2112, CSD2112R Cool Zinc Gray WC64C7, WC80G1, WC80H2, WC80J2, WC80K2 T9 HT10, HT05, CSD2102R, (3)CSA2102L, (2)CSA1072L, CSA1042L, CSF1042 Cool Granite Gray WC64C7, WC80G1, WC80H2, WC80J2, WC80K2 T10 (5)GAC1124, (10)NLTA10 Cool Granite Gray WC61G2 Fastener Schedule Part Description 0097584-116 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097584-110 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097584-112 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097581-116 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 0097581-112 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer Shape Name = 156 x100x26(HS), Wall = 1 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\39 CedarpointFinalR5.vpc1_COVERING ELEVATION AT D.dwg 7/11/2022 10:44:09SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. COVERING ELEVATION AT D 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 39NTS 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. PERMIT SET- For Building Dept. Approval COVERING ELEVATION AT D T10 T9 T8 T7 T6 T5T5 T4 T4 T4 T4 T4 T4 T4 T4 T3T2T1 BL 5 BL 1 NBVP - Masonry 29'-6"16'-0"7'-0"16'-0"31'-6" (11)#60 (4)#61 (4)#60 (4)#61 (11)#60 2' - 0 " (11)#59(4)#59(11)#59 21 ' - 8 " 100'-0" 07/12/2022 Covering Schedule Id Qty Type Start Length Gage OP Fin.Color Increment Direction #62 2 W 5'-5 1/2"26 F K GZ Left to Right #63 1 W 11'-9"26 1 K GG Left to Right #64 3 W 4'-9 1/2"26 1 K GG 1 1/2"Left to Right #65 1 W 12'-3"26 1 K GG Left to Right Oper. Code:F=CR, SQ Oper. Code:1=SQ, SQ Finish:K=KXL (Kynar) Color:GZ=Cool Zinc Gray Color:GG=Cool Granite Gray Trim Schedule Id Parts Color Details T1 DFT10, JT07 Cool Ebony WC24A1 T2 DFT12, HTS12 Cool Ebony WC24A2 T3 (2)RFR10-130, RKF16, (2)RSB10, (2)RSC10 Cool Ebony RC10A1, RC30A1, RS10L5 T4 CT10 Match Wall Color WC20A1 T5 CT05 Match Wall Color WC20A1 T6 CT12 Match Wall Color WC20A1 Fastener Schedule Part Description 0097581-116 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 0097581-112 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 1 2'-7" 2 1'-5" Dimension Key Shape Name = 15x50'-6"x19'-6"(HS), Wall = 1 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\40 CedarpointFinalR5.vpc1_COVERING ELEVATION AT 1 (b).dwg 7/11/2022 10:47:56SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. COVERING ELEVATION AT 1 (b) 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 40NTS 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. PERMIT SET- For Building Dept. Approval COVERING ELEVATION AT 1 T6 T5 T4 T3 T2 T1 T1 T1 T1 #65 12 ' - 3 " 5' - 0 1 / 2 " 4' - 1 1 " 4' - 9 1 / 2 " #63 11 ' - 9 " #62 5' - 5 1 / 2 " #62 5' - 5 1 / 2 " BL B BL A NBVP - MasonryNBVP - Masonry 211'-0"1 (3)#64 2' - 0 " 19 ' - 6 " 18 ' - 1 0 1 / 2 " 15'-0" 07/12/2022 Id Covering Schedule Qty Type Start Length Gage OP Fin.Color Direction #70 17 W 5'-5 1/2"26 F K GZ Left to Right #71 17 W 12'-0"26 1 K GG Left to Right Oper. Code:F=CR,SQ Oper. Code:1=SQ,SQ Finish:K=KXL (Kynar) Color:GZ=Cool Zinc Gray Color:GG=Cool Granite Gray Id Trim Schedule Parts Color Details T1 (2)EF20A,EF12A,(6)RFR10-130 Cool Ebony RC03A2,RC31A1,RCV536,WC04G1,WC11F1 T2 CT10 Match Wall Color WC20A1 T3 CT05 Match Wall Color WC20A1 T4 CT12 Match Wall Color WC20A1 Part Fastener Schedule Description 0097581-116 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 0097581-112 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer NBVP - Masonry 50'-6" 18 ' - 1 0 1 / 2 " 3 BL 1 BL (17)#70 2' - 0 " (17)#71 T1 T2 T3 T4 COVERING ELEVATION AT A VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D COVERING ELEVATION AT A Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 41 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. Shape Name = 15x50'-6"x19'-6"(HS), Wall = 2 8:45:147/5/2022 07/12/2022 Covering Schedule Id Qty Type Start Length Gage OP Fin.Color Increment Direction #74 5 W 5'-5 1/2"26 F K GZ Left to Right #75 5 W 12'-3"26 1 K GG -1 1/2"Left to Right Oper. Code:F=CR, SQ Oper. Code:1=SQ, SQ Finish:K=KXL (Kynar) Color:GZ=Cool Zinc Gray Color:GG=Cool Granite Gray Trim Schedule Id Parts Color Details T1 (2)RFR10-130, RKF16, (2)RSB10, (2)RSC10 Cool Ebony RC10A1, RC30A1, RS10L5 Fastener Schedule Part Description 0097581-116 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 0097581-112 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer Shape Name = 15x50'-6"x19'-6"(HS), Wall = 3 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\42 CedarpointFinalR5.vpc1_COVERING ELEVATION AT 3.dwg 7/11/2022 10:50:42SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. COVERING ELEVATION AT 3 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 42NTS 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. PERMIT SET- For Building Dept. Approval COVERING ELEVATION AT 3 T1 11 ' - 9 " 11 ' - 1 0 1 / 2 " 12 ' - 0 " 12 ' - 1 1 / 2 " 12 ' - 3 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " 5' - 5 1 / 2 " BL A BL B NBVP - Masonry (5)#75 2' - 0 " (5)#74 18 ' - 1 0 1 / 2 " 19 ' - 6 " 15'-0" 07/12/2022 Shape Name = 15x50'-6"x19'-6"(HS), Wall = 4 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\43 CedarpointFinalR5.vpc1_COVERING ELEVATION AT B (b).dwg 7/11/2022 10:52:27SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. COVERING ELEVATION AT B (b) 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 43NTS 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. PERMIT SET- For Building Dept. Approval COVERING ELEVATION AT B Opening 2 BL 3 BL 1 2' - 0 " 19 ' - 6 " 50'-6" 07/12/2022 Covering Schedule Id Qty Type Start Length Gage OP Fin.Color Increment Direction #79 4 W 5'-5 1/2"26 F K GZ Left to Right #80 2 W 11'-0 3/4"26 1 K GG 1 1/2"Left to Right #81 1 W 8'-4 3/4"26 1 K GG Left to Right #82 2 W 11'-5 1/4"26 1 K GG 1 1/2"Left to Right Oper. Code:F=CR, SQ Oper. Code:1=SQ, SQ Finish:K=KXL (Kynar) Color:GZ=Cool Zinc Gray Color:GG=Cool Granite Gray Trim Schedule Id Parts Color Details T1 (0.2)BG2415 Cool Zinc Gray EN52A1, ENV003, RC00A1, WC01D9, WC04G1, WS27B2, WS27D2 T2 DFT10, JT07 Cool Ebony WC24A1 T3 DFT05, JT05 Cool Ebony WC24A1 T4 DFT10, HTS10 Cool Ebony WC24A2 T5 GAC1024, (2)NLTB10, 1CS2046L, (3)CSA2056L, (2)CSA2102L, CSA1075L Cool Granite Gray RC80E2, RC80E3, RC80G1, RC80G4, WC12A2 T6 HT14 Cool Granite Gray WC64C7, WC80G1, WC80H2, WC80J2, WC80K2 T7 HT07 Match Wall Color WC64C7, WC80G1, WC80H2, WC80J2, WC80K2 T8 HT12, CSD2102L, (2)CSA2072R, CSA2102R, CSA1054R, CSF1054 Cool Granite Gray WC64C7, WC80G1, WC80H2, WC80J2, WC80K2 T9 HT07, CSF2112, CSD2112L Match Wall Color WC64C7, WC80G1, WC80H2, WC80J2, WC80K2 Fastener Schedule Part Description 0097584-116 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097584-110 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097584-112 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097581-116 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 0097581-112 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 1 3'-6" Dimension Key Shape Name = 15x50'-6"x19'-6"(HS), Wall = 1 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\44 CedarpointFinalR5.vpc1_COVERING ELEVATION AT PARTITION OR MISC. 1.dwg 7/11/2022 10:56:10SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. COVERING ELEVATION AT PARTITION OR MISC. 1 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 44NTS 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. PERMIT SET- For Building Dept. Approval COVERING ELEVATION AT PARTITION OR MISC. 1 T9 T8 T7 T6 T5 T4 T3T3 T2 T2 T1T1 (2)#82 11 ' - 6 3 / 4 " 11 ' - 5 1 / 4 " #81 8' - 4 3 / 4 " (2)#80 11 ' - 2 1 / 4 " 11 ' - 0 3 / 4 " (2)#79 5' - 5 1 / 2 " 5' - 5 1 / 2 " (2)#79 5' - 5 1 / 2 " 5' - 5 1 / 2 " BL B BL A CMU Stem Wall 18'-0"1 2' - 0 " 19 ' - 6 " 18 ' - 1 0 1 / 2 " 15'-0" 07/12/2022 Wall Liner Schedule Id Qty Type Length Gage OP Finish Color Increment Direction #11 17 PR 5'-7 1/2"26 F K GZ Left to Right #12 3 PR 15'-2"26 1 K GG -1 1/2"Left to Right #13 4 PR 7'-5 1/2"26 1 K GG -1 1/2"Left to Right #14 3 PR 14'-3 1/2"26 1 K GG -1 1/2"Left to Right #15 5 PR 6'-7"26 1 K GG -1 1/2"Left to Right #16 5 PR 13'-3 1/2"26 1 K GG -1 1/2"Left to Right #17 4 PR 5'-4"26 1 K GG -1 1/2"Left to Right #18 3 PR 12'-2"26 1 K GG -1 1/2"Left to Right #19 5 PR 4'-5 1/2"26 1 K GG -1 1/2"Left to Right #20 3 PR 11'-2"26 1 K GG -1 1/2"Left to Right Oper. Code:F=CR, SQ Oper. Code:1=SQ, SQ Finish:K=KXL (Kynar) Color:GZ=Cool Zinc Gray Color:GG=Cool Granite Gray Trim Schedule Id Parts Color Details T1 JT07 Match Wall Color WC24A1, WCV060 T2 JT07 Match Wall Color WC24A1, WCV060 T3 (2)HTL10 Match Wall Color WC25A3, WCV060 T4 JT05 Match Wall Color WC24A1, WCV060 T5 HTL10 Match Wall Color WC25A3, WCV060 T6 HT05 Match Wall Color WC31A3 T7 NLTB05, TA10 Match Wall Color WC61A4, WCV060 T8 (5)NLTB10, NLTB05, (3)TA10 Match Wall Color WC61A4, WCV060 T9 (5)NLTB10, NLTB05, (3)TA10 Match Wall Color WC61A4, WCV060 T10 (2)JT10 Match Wall Color WC61A8 T11 (3)JT10 Match Wall Color WC61A8 T12 (4)JT10 Match Wall Color WC61A8 Fastener Schedule Part Description 0097584-116 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097581-116 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 0097584-112 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097581-112 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer Shape Name = 156 x100x26(HS), Wall = 1 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\45 CedarpointFinalR5.vpc1_WALL LINER ELEVATION AT 1 (a).dwg 7/11/2022 12:45:48SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. WALL LINER ELEVATION AT 1 (a) 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 45NTS 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. PERMIT SET- For Building Dept. Approval (View from inside Building) WALL LINER ELEVATION AT 1 T1 2 T1 2 T1 1 T1 1 T1 0 T1 0 T1 0 T1 0 T9 T8 T8 T7 T7 T6 T6 T6 T6 T6 T6 T6 T6 T5 T5 T5 T5 T5 T5 T5 T5 T4 T4 T4 T4 T4 T4 T4 T4 T4 T4 T4 T4 T4 T4 T4 T4 T3 T3 T3 T3 T2 T2 T2 T2 T2 T2 T2 T2 T1 T1 T1 T1 T1 T1 T1 T1 10 ' - 1 1 " 11 ' - 0 1 / 2 " 11 ' - 2 " 3' - 1 1 1 / 2 " 4' - 1 " 4' - 2 1 / 2 " 4' - 4 " 4' - 5 1 / 2 " 11 ' - 1 1 " 12 ' - 0 1 / 2 " 12 ' - 2 " 4' - 1 1 1 / 2 " 5' - 1 " 5' - 2 1 / 2 " 5' - 4 " 12 ' - 9 1 / 2 " 12 ' - 1 1 " 13 ' - 0 1 / 2 " 13 ' - 2 " 13 ' - 3 1 / 2 " 6' - 1 " 6' - 2 1 / 2 " 6' - 4 " 6' - 5 1 / 2 " 6' - 7 " 14 ' - 0 1 / 2 " 14 ' - 2 " 14 ' - 3 1 / 2 " 7' - 1 " 7' - 2 1 / 2 " 7' - 4 " 7' - 5 1 / 2 " 14 ' - 1 1 " 15 ' - 0 1 / 2 " 15 ' - 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " BL B BL J NBVP - Other Open 59'-6"16'-0"6'-0"16'-0"13'-0"16'-0"6'-0"16'-0"7'-6" (3)#20 (5)#19 (3)#18 (4)#17 (5)#16 (5)#15 (3)#14 (4)#13 (3)#12 (3)#11(3)#11(5)#11(3)#11(3)#11 26 ' - 0 " 19 ' - 6 " 156'-0" NBVP - Other NBVP - OtherNBVP - Other 07/12/2022 Wall Liner Schedule Id Qty Type Length Gage OP Finish Color Direction #25 31 PR 5'-7 1/2"26 F K GZ Left to Right #26 1 PR 4'-11 1/2"26 F K GZ Left to Right #27 13 PR 12'-5"26 1 K GG Left to Right #28 3 PR 11'-11"26 1 K GG Left to Right #29 18 PR 11'-4 7/8"26 1 K GG Left to Right Oper. Code:F=CR, SQ Oper. Code:1=SQ, SQ Finish:K=KXL (Kynar) Color:GZ=Cool Zinc Gray Color:GG=Cool Granite Gray Trim Schedule Id Parts Color Details T1 ICF05 Match Wall Color WC21A1 T2 ICF10 Match Wall Color WC21A1 T3 ICF16 Match Wall Color WC21A1 T4 JT07 Match Wall Color WC24A1, WCV060 T5 HTL10 Match Wall Color WC25A3, WCV060 T6 (3)GAC1124, (5)NLTA10 Match Wall Color WC61G2 T7 (2)JT10 Match Wall Color WC61A8, WC61A9 T8 (3)JT10 Match Wall Color WC61A8, WC61A9 Fastener Schedule Part Description 0097584-116 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097581-116 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 0097584-112 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097581-112 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer Shape Name = 156 x100x26(HS), Wall = 2 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\46 CedarpointFinalR5.vpc1_WALL LINER ELEVATION AT B.dwg 7/11/2022 12:45:18SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. WALL LINER ELEVATION AT B 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 46NTS 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. PERMIT SET- For Building Dept. Approval (View from inside Building) WALL LINER ELEVATION AT B T8 T8 T8 T8 T8 T8 T7 T7 T7 T7 T7 T7 T6 T5 T4 T4 T3 T2 T1 #26 BL 5 BL 1 NBVP - Other Open 25'-8"8'-4"66'-0" (18)#29 (4)#27(3)#28(9)#27 (22)#25(9)#25 19 ' - 6 " 19 ' - 6 " 100'-0" 07/12/2022 Wall Liner Schedule Id Qty Type Length Gage OP Finish Color Increment Direction #40 17 PR 5'-7 1/2"26 F K GZ Left to Right #41 3 PR 10'-11 1/2"26 1 K GG 1 1/2"Left to Right #42 4 PR 4'-0"26 1 K GG 1 1/2"Left to Right #43 3 PR 11'-10"26 1 K GG 1 1/2"Left to Right #44 5 PR 4'-10 1/2"26 1 K GG 1 1/2"Left to Right #45 5 PR 12'-10"26 1 K GG 1 1/2"Left to Right #46 4 PR 6'-1 1/2"26 1 K GG 1 1/2"Left to Right #47 3 PR 13'-11 1/2"26 1 K GG 1 1/2"Left to Right #48 5 PR 7'-0"26 1 K GG 1 1/2"Left to Right #49 3 PR 14'-11 1/2"26 1 K GG 1 1/2"Left to Right Oper. Code:F=CR, SQ Oper. Code:1=SQ, SQ Finish:K=KXL (Kynar) Color:GZ=Cool Zinc Gray Color:GG=Cool Granite Gray Trim Schedule Id Parts Color Details T1 JT07 Match Wall Color WC24A1, WCV060 T2 JT07 Match Wall Color WC24A1, WCV060 T3 (2)HTL10 Match Wall Color WC25A3, WCV060 T4 JT05 Match Wall Color WC24A1, WCV060 T5 HTL10 Match Wall Color WC25A3, WCV060 T6 HT05 Match Wall Color WC31A3 T7 (5)NLTB10, NLTB05, (3)TA10 Match Wall Color WC61A4, WCV060 T8 (5)NLTB10, NLTB05, (3)TA10 Match Wall Color WC61A4, WCV060 T9 NLTB05, TA10 Match Wall Color WC61A4, WCV060 T10 (2)JT10 Match Wall Color WC61A8 T11 (4)JT10 Match Wall Color WC61A8 T12 (3)JT10 Match Wall Color WC61A8 Fastener Schedule Part Description 0097584-116 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097581-116 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 0097584-112 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097581-112 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer Shape Name = 156 x100x26(HS), Wall = 3 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\47 CedarpointFinalR5.vpc1_WALL LINER ELEVATION AT 5.dwg 7/11/2022 13:13:19SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. WALL LINER ELEVATION AT 5 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 47NTS 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. PERMIT SET- For Building Dept. Approval (View from inside Building) WALL LINER ELEVATION AT 5 T1 2 T1 2 T1 1 T1 1 T1 0 T1 0 T1 0 T1 0 T9 T9 T8 T8 T7 T6T6 T6T6 T6T6 T6T6 T5T5 T5T5 T5T5 T5T5 T4 T4T4T4 T4 T4T4T4 T4 T4T4T4 T4 T4T4T4 T3 T3 T3 T3 T2 T2 T2 T2 T2 T2 T2 T2 T1 T1 T1 T1 T1 T1 T1 T1 15 ' - 2 1 / 2 " 15 ' - 1 " 14 ' - 1 1 1 / 2 " 7' - 6 " 7' - 4 1 / 2 " 7' - 3 " 7' - 1 1 / 2 " 7' - 0 " 14 ' - 2 1 / 2 " 14 ' - 1 " 13 ' - 1 1 1 / 2 " 6' - 6 " 6' - 4 1 / 2 " 6' - 3 " 6' - 1 1 / 2 " 13 ' - 4 " 13 ' - 2 1 / 2 " 13 ' - 1 " 12 ' - 1 1 1 / 2 " 12 ' - 1 0 " 5' - 4 1 / 2 " 5' - 3 " 5' - 1 1 / 2 " 5' - 0 " 4' - 1 0 1 / 2 " 12 ' - 1 " 11 ' - 1 1 1 / 2 " 11 ' - 1 0 " 4' - 4 1 / 2 " 4' - 3 " 4' - 1 1 / 2 " 4' - 0 " 11 ' - 2 1 / 2 " 11 ' - 1 " 10 ' - 1 1 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " BL J BL B NBVP - Other Open 7'-6"16'-0"6'-0"16'-0"13'-0"16'-0"6'-0"16'-0"7'-6"52'-0" (3)#49 (5)#48 (3)#47 (4)#46 (5)#45 (5)#44 (3)#43 (4)#42 (3)#41 (3)#40(3)#40(5)#40(3)#40(3)#40 19 ' - 6 " 26 ' - 0 " 156'-0" 07/12/2022 Wall Liner Schedule Id Qty Type Length Gage OP Finish Color Increment Direction #66 2 PR 5'-7 1/2"26 F K GZ Left to Right #67 1 PR 10'-10"26 1 K GG Left to Right #68 3 PR 3'-4 1/2"26 1 K GG -1 1/2"Left to Right #69 1 PR 10'-4"26 1 K GG Left to Right Oper. Code:F=CR, SQ Oper. Code:1=SQ, SQ Finish:K=KXL (Kynar) Color:GZ=Cool Zinc Gray Color:GG=Cool Granite Gray Trim Schedule Id Parts Color Details T1 JT07 Match Wall Color WC24A1, WCV060 T2 JT07 Match Wall Color WC24A1, WCV060 T3 (2)HTL10 Match Wall Color WC25A3, WCV060 T4 (2)NLTB10, TA10 Match Wall Color WC61A4, WCV060 T5 (2)JT10 Match Wall Color WC61A8, WC61A9 T6 (3)JT10 Match Wall Color WC61A8, WC61A9 Fastener Schedule Part Description 0097584-116 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097581-116 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 0097584-112 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097581-112 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer Shape Name = 15x50'-6"x19'-6"(HS), Wall = 1 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\48 CedarpointFinalR5.vpc1_WALL LINER ELEVATION AT 1 (b).dwg 7/11/2022 13:22:59SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. WALL LINER ELEVATION AT 1 (b) 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 48NTS 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. PERMIT SET- For Building Dept. Approval (View from inside Building) WALL LINER ELEVATION AT 1 T6 T5 T4 T3 T2 T2 T1 T1 #69 10 ' - 4 " 3' - 1 1 / 2 " 3' - 3 " 3' - 4 1 / 2 " #67 10 ' - 1 0 " #66 5' - 7 1 / 2 " #66 5' - 7 1 / 2 " BL A BL B NBVP - Other Open 1'-5"11'-0"2'-7" (3)#68 19 ' - 6 " 18 ' - 1 0 1 / 2 " 15'-0" 07/12/2022 Id Wall Liner Schedule Qty Type Length Gage OP Finish Color Direction #72 17 PR 5'-7 1/2"26 F K GZ Left to Right #73 17 PR 10'-9 3/8"26 1 K GG Left to Right Oper. Code:F=CR,SQ Oper. Code:1=SQ,SQ Finish:K=KXL (Kynar) Color:GZ=Cool Zinc Gray Color:GG=Cool Granite Gray Id Trim Schedule Parts Color Details T1 (3)GAC1124,(4)NLTA10,NLTA05 Match Wall Color WC61G2 T2 (2)JT10 Match Wall Color WC61A8,WC61A9 T3 (3)JT10 Match Wall Color WC61A8,WC61A9 T4 GAC1124,NLTA10 Match Wall Color WC61G2 Part Fastener Schedule Description 0097584-116 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097581-116 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 0097584-112 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097581-112 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer Open NBVP - Other 50'-6" 18 ' - 1 0 1 / 2 " 18 ' - 1 0 1 / 2 " 1 BL 3 BL (17)#72 (17)#73 T1 T2T2T2T2 T3T3T3T3 T4 WALL LINER ELEVATION AT A (View from inside Building) VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D WALL LINER ELEVATION AT A Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 49 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. Shape Name = 15x50'-6"x19'-6"(HS), Wall = 2 8:45:267/5/2022 07/12/2022 Wall Liner Schedule Id Qty Type Length Gage OP Finish Color Increment Direction #76 5 PR 5'-7 1/2"26 F K GZ Left to Right #77 5 PR 10'-4"26 1 K GG 1 1/2"Left to Right Oper. Code:F=CR, SQ Oper. Code:1=SQ, SQ Finish:K=KXL (Kynar) Color:GZ=Cool Zinc Gray Color:GG=Cool Granite Gray Trim Schedule Id Parts Color Details T1 (2)NLTB10, TA10 Match Wall Color WC61A4, WCV060 Fastener Schedule Part Description 0097584-116 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097581-116 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 0097584-112 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097581-112 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer Shape Name = 15x50'-6"x19'-6"(HS), Wall = 3 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\50 CedarpointFinalR5.vpc1_WALL LINER ELEVATION AT 3.dwg 7/11/2022 13:26:49SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. WALL LINER ELEVATION AT 3 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 50NTS 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. PERMIT SET- For Building Dept. Approval (View from inside Building) WALL LINER ELEVATION AT 3 T1 10 ' - 1 0 " 10 ' - 8 1 / 2 " 10 ' - 7 " 10 ' - 5 1 / 2 " 10 ' - 4 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " 5' - 7 1 / 2 " BL B BL A NBVP - Other Open (5)#77 (5)#76 18 ' - 1 0 1 / 2 " 19 ' - 6 " 15'-0" 07/12/2022 Wall Liner Schedule Id Qty Type Length Gage OP Finish Color Increment Direction #83 4 PR 5'-5 1/2"26 F K GZ Left to Right #84 2 PR 11'-8 3/4"26 1 K GG -1 1/2"Left to Right #85 1 PR 7'-11 3/4"26 1 K GG Left to Right #86 2 PR 11'-4 1/4"26 1 K GG -1 1/2"Left to Right Oper. Code:F=CR, SQ Oper. Code:1=SQ, SQ Finish:K=KXL (Kynar) Color:GZ=Cool Zinc Gray Color:GG=Cool Granite Gray Trim Schedule Id Parts Color Details T1 JT05 Match Wall Color WC24A1, WCV060 T2 JT05 Match Wall Color WC24A1, WCV060 T3 HTL10 Match Wall Color WC25A3, WCV060 T4 GAC1024, (2)NLTB10, 1CS2046R, (3)CSA2056R, (2)CSA2102R, CSA1075R Match Wall Color RC80E2, RC80E3, RC80G1, RC80G4, WC12A2 T5 HT05 Match Wall Color WC64C7, WC80G1, WC80H2, WC80J2, WC80K2 T6 HT12, CSD2102R, (2)CSA2072L, CSA2102L, CSA1054L, CSF1054 Match Wall Color WC64C7, WC80G1, WC80H2, WC80J2, WC80K2 T7 HT05 Match Wall Color WC64C7, WC80G1, WC80H2, WC80J2, WC80K2 T8 HT14 Match Wall Color WC64C7, WC80G1, WC80H2, WC80J2, WC80K2 Fastener Schedule Part Description 0097584-116 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097581-116 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer 0097584-112 (T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer 0097581-112 (T-1) 1/4-14 x 7/8", 5/16" Hex Hd, SS Cap w/Washer Shape Name = 15x50'-6"x19'-6"(HS), Wall = 1 JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. FILENAME: C:\Users\isflores\OneDrive - BlueScope\Desktop\ORDERS\01 PERMIT DRAWINGS\01 - 22-012241-01\01 VISION FILE\PERMIT\51 CedarpointFinalR5.vpc1_WALL LINER ELEVATION PARTITION OR MISC. 1.dwg 7/11/2022 14:39:04SAVE DATE:SAVE TIME:LAST SAVED BY:isflores MO D I F I E D I N A U T O C A D VPC VERSION: VP Buildings 3200 Players Club Circle Memphis TN 38125DTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. WALL LINER ELEVATION PARTITION OR MISC. 1 2022.1b Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF GPH 51NTS 1. PRE-DRILLING 1/8 DIAMETER HOLES FOR STRUCTURAL FASTENERS MAY BE REQUIRED FOR HEAVY GAGE NESTED ZEE's AND/OR FASTENERS TO STRUCTURAL BEAMS 2. STEEL PANELS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM. REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED. 3. DUE TO MANUFACTURING LIMITATIONS SHORT PANELS MAY REQUIRE FIELD CUTTING, SEE THE COVERING SCHEDULE FOR CUT LENGTHS. 4. SEE JOB DETAILS FOR COVERING AND TRIM FASTENER SPECIFICATION. PERMIT SET- For Building Dept. Approval (View from inside Building) WALL LINER ELEVATION PARTITION OR MISC. 1 T8 T7 T7 T6 T5 T5 T4 T3 T2 T2 T2 T2 T1 T1 (2)#86 11 ' - 2 3 / 4 " 11 ' - 4 1 / 4 " #85 7' - 1 1 3 / 4 " (2)#84 11 ' - 7 1 / 4 " 11 ' - 8 3 / 4 " (2)#83 5' - 5 1 / 2 " 5' - 5 1 / 2 " (2)#83 5' - 5 1 / 2 " 5' - 5 1 / 2 " BL A BL B NBVP - Other Open 3'-6"8'-0"3'-6" 19 ' - 6 " 18 ' - 1 0 1 / 2 " 15'-0" 07/12/2022 VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D COVERING & TRIM SED'S (a) Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 52 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 8:45:327/5/2022 SEDSheet 07/12/2022 VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D COVERING & TRIM SED'S (b) Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 53 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 8:45:347/5/2022 SEDSheet 07/12/2022 VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D COVERING & TRIM SED'S (c) Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 54 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 8:45:357/5/2022 SEDSheet 07/12/2022 VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D COVERING & TRIM SED'S (d) Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 55 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 8:45:377/5/2022 SEDSheet 07/12/2022 VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D B-081465 Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 56 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 12:48:557/7/2022 SEDSheet 07/12/2022 VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D B-081765 Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 57 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 12:57:077/7/2022 SEDSheet 07/12/2022 VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D S-081766 Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 58 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 12:59:247/7/2022 SEDSheet 07/12/2022 VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D S-081767 Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 59 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 13:02:097/7/2022 SEDSheet 07/12/2022 VPC VERSION: FILENAME: JOBNO DATE DRAWN/CHECK PAGE BUILDER CUSTOMER LOCATION PROJECT BUILDERS PO# DATEREV BY DESCRIPTION VP BUILDINGS VARCO PRUDEN VP Buildings 3200 Players Club Circle Memphis TN 38125 A BlueScope Steel Company a division of BlueScope Buildings North America, Inc. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP. D S-090028 Titan Steel Rexburg, Idaho Cedarpoint Final 22-012241 07/11/2022 ITF 60 CedarpointFinalR5.vpc1 2022.1bNTS GPH PERMIT SET- For Building Dept. Approval 13:04:497/7/2022 SEDSheet 07/12/2022